Overbrook Scientific
Providers of Analytical Instrumentation
Providers of Instrument Support and Peripheral Services
Distributors of the HTA Line of Autosamplers
HTA Autosamplers
HT300A Liquid Sampler
HT200H Headspace Sampler
HT250D Liquid/Headspace Sampler
HT280T (SPME) Headspace Sampler
HTA Autosamplers
“High Throughput Automation”
Manufactured in Italy
Reputation for quality workmanship
HT 300A - Key Features Replacement sampler- any major manufactured GC Extremely Rugged Rotating Turret Design No picking up of the vial Handles Front and Back Injectors Small footprint Economical - $8,500 Accurate – Reproducibility Typically .3% Very Easy to use Nice Looking (Italian) Control Software Available including Agilent Chemstation
Headspace Europeans to date have a higher level of
proficiency due to experience
More Widely Used
More Widely Accepted Blood Alcohol Residual Solvents Environmental R&D
Advantages of Headspace in the Environmental Laboratory
Pre-screening for VOC’s – Aqueous and Solids EPA 8260 Aqueous and Solids Methods 624 Waste Water, 524 Drinking Water
Why Gamble on Sample Throughput? Protecting a Lucrative Revenue Stream Decrease Downtime From Contamination Protect your MS System and Sustain Productivity by
Pre-screening
HT200H Headspace Sampler Key Features
Cost effective ($17,900) Inexpensive to Operate Small Footprint Rotating Turret Front and Back Injectors - Run Multiple Methods Direct Injection – No Transfer Line Leaves Inlet Intact No Carryover Very Short Runtime (under 10 min. Including Naphthalene)
HT250D Dual Autosampler
Headspace and Liquid Autosampler in one unit
All the features of HT200H plus features of HT300A
Easy to change from one mode to the other All included – no optional extras Maximizes the throughput on individual GC’s Small Footprint Most Economical Dual Unit on the Market
EPA Method 8260 Pre-screening
Volatiles partition into vial headspace1ml gas-tight syringe injectionGC/FID SystemUse reduced compound list or reference
calibration (aromatic and chlorinateds)Dilute appropriately and run by
P&T/GC/MS
Method RSK 175
An umbrella EPA Method for permanent gas analysis
USEPA Region 1 application notes applied to MNA
Standards readily available from Scott & Restek
Analyze Methane/Ethane/Ethene to 2ug/L Remember Methane is a Reportable
Compound in MA
CCME Method 1310
Canadian Petroleum Hydrocarbon Method for VPH/GRO
Performance based method allows for Headspace Preparation to reduce carryover contamination
PBM Criteria require strict alkane/ aromatic ratios
Pre-screen UST Samples – no reruns for baseline resolution issues
Business Opportunities with Headspace
CCME 1310Materials TestingUSP 467 Residual Solvents Raw Materials from ChinaVOA’s (Raw production Material that
cannot be prepared by P&T)