Upload
phamkien
View
213
Download
0
Embed Size (px)
Citation preview
Cisco 7378-13279-01 B0
C H A P T E R 1
OverviewThe Cisco 7304 router is a high-performance Enterprise Edge LAN/WAN integration and service provider aggregation router.
This chapter provides a quick hardware overview and installation instructions for the Cisco 7304 router. For functional information, see Chapter 3, “Starting and Configuring,” the “Functional Overview” section on page 3-1. For system specifications and port and cabling specifications, see Appendix A, “Specifications.”
This chapter includes the following sections:
• Hardware Overview, page 1-1
• Checking the Shipping Container Contents, page 1-10
• Installation Checklist, page 1-10
Warning Before you install, operate, or service the system, read the Site Preparation and Safety Guide. This guide contains important safety information you should know before working with the system.
Hardware OverviewThe Cisco 7304 router supports the following features:
• Online insertion and removal (OIR)—Allows you to add, replace, or remove line cards without interrupting the system
• Environmental monitoring and reporting functions—Allow you to maintain normal system operation by resolving adverse environmental conditions prior to loss of operation
• Downloadable software—Allows you to load new images into Flash memory remotely, without having to physically access the router, for fast, reliable upgrades
• Small form-factor—Four rack-units high with stacking capability: 6.94 in. x 17.6 in. x 20.5 in. (17.63 cm x 44.70 cm x 52.07 cm)
• Front to back airflow—Allows you to mount the router from either front or back into 2-post and 4-post 19- inch and 21–23 inch racks
The following sections provide illustrations and a brief overview of the Cisco 7304 router:
• Front View, page 1-2
• LEDs on the NSE-100, page 1-3
• LEDs on the NSE-150, page 1-4
1-104 Installation and Configuration Guide
Chapter 1 Overview Hardware Overview
• LEDs on the NPE-G100, page 1-5
• Rear View, page 1-7
• System Board NSE–100, page 1-8
• System Board—NSE-150, page 1-8
• System Board—NPE-G100, page 1-9
• System Management Functions, page 1-9
Front View
Figure 1-1 Cisco 7304 Router—Front View (NSE-100 Shown)
The Cisco 7304 router supports:
• A processing engine containing both I/O functionality and the route processor. The following processing engines are available:
– Network Services Engine 100 (NSE-100)—Three Ethernet interfaces: three physical Ethernet ports, two Gigabit Ethernet (1000-Mbps) ports and a Fast Ethernet management (10/100-Mbps) port with an RJ-45 connector
– Network Services Engine 150 (NSE-150)- Five Ethernet interfaces: four Gigabit Ethernet small form factor pluggable (SFP) ports and a Fast Ethernet management (10/100-Mbps) port with an RJ-45 connector
– Network Processing Engine (NPE-G100)—Three Gigabit Ethernet interfaces: six physical Gigabit Ethernet ports, three small form factor pluggable (SFP) ports and three RJ-45 ports. Any three are usable at any one time
• A 256-MB CompactFlash Disk
• Power supplies that are available in four options: single AC, dual AC, single –48 VDC, anddual –48 VDC
PRIMARY
DISK 0
9K-NSE 100
NETWORK SERVICES ENGINE 100
RESET
LINK
GE 0
RXTX
LINK
GE 1
LINK
PE 0
AUX
CONSOLE
RXTX
COMPACT FLASH
SECONDARYSYSTEM-UP
TX
9K-10C48
1-PORT OC48 POS w/ SMSR
OIR
STATUS
RX
OIR
STATUS
9K-40C3/POS-MM
4-PORT OC3 POS w/ MM
OIR
STATUS
CARRIER/ALARM
0
ACTIVE/LOOPBACK
12
3
5770
5
1-2Cisco 7304 Installation and Configuration Guide
78-13279-01 B0
Chapter 1 Overview Hardware Overview
LEDs on the NSE-100NSE-100 LED information is in Figure 1-2 and Table 1-1 below.
Figure 1-2 LEDs on the NSE-100
Table 1-1 NSE-100 LEDs
LED Label Color State FunctionDISK 0 Green/Yellow Green CompactFlash Disk is being accessed.
Yellow CompactFlash Disk access failure.
Off Default state on power up.
GE0 LINK Green/Yellow Green Gigabit Ethernet port 0 is up.
Yellow Gigabit Ethernet port 0 line protocol is down due to a link error or other conditions.
Off Default state on power up, Gigabit Ethernet port 0 has been administratively shut down, or a fatal hardware error has occurred.
GE1 LINK Green/Yellow Green Gigabit Ethernet port 1 is up.
Yellow Gigabit Ethernet port 1 line protocol is down due to a link error or other conditions.
Off Default state on power up, Gigabit Ethernet port 1 has been administratively shut down, or a fatal hardware error has occurred.
FE Manage-ment Port LINK
Green/Yellow On Fast Ethernet physical link is up.
Yellow Line protocol is down due to a link error.
Off Default state on power up or has been administratively shut down.
PRIMARY Green On NSE is up and running.
Off Default state on power up.
SECONDARY Green On Green when this NSE is the standby NSE.
Off Off when the NSE is not active.
6605
1
PRIMARY
7300-NSE-100
DISK 0
RESET
LINK
GE 0
RX TXLINK
GE 1FE MANAGEMENT
PORT
LINK
AUXCONSOLE
RX TX
COMPACT FLASH
SECONDARY
NETWORK SERVICES ENGINE 100
SYSTEM-UP
324 5 6 7
1-3Cisco 7304 Installation and Configuration Guide
78-13279-01 B0
Chapter 1 Overview Hardware Overview
LEDs on the NSE-150NSE-100 LED information is in Figure 1-3 and Table 1-1 below.
Figure 1-3 LEDs on the NSE-150
Table 1-2 NSE-150 LEDs
SYSTEM-UP Green/Yellow Green Cisco IOS is up and running.
Yellow ROMmon is booting up, ROMmon detects a fatal hardware error, or ROMmon is hanging before the system completes the bootup process.
Off ROMmon has completed the bootup process and the sys-tem either is in the autoboot stage or is waiting for a user command at a rommon#> prompt.
Table 1-1 NSE-100 LEDs (continued)
LED Label Color State Function
7300-NSE-150
CONSOLEUSB
LINKDISK 0
FOR MANAGEMENT USE ONLY
COMPACT FLASH
SFP
LINK
GIGABIT ETHERNET 3
0 1
FE 0 AUX
THIS ASSEMBLYCONTAINSELECTRO-STATICSENSITIVE DEVICES
CAUTION:
SFP
LINK
GIGABIT ETHERNET 2
SFP
LINK
GIGABIT ETHERNET 1
SFP
LINKSTANDBY
RESET
ACTIVE
NETWORK SERVICE ENGINE 150
CLASS 1 LASER PRODUCT / LASERPRODUKT DE KLASS 1 / PRDUIT LASER DE CLASE 1 / PRODUCTO LASER CLASE 1 /
SYSTEM-UP
GIGABIT ETHERNET 0
1
1580
20
LED Label Color State FunctionACTIVE Green On NSE is up and running.
Off NSE is off. Default state on power up.
SYSTEM-UP Green/Yellow Green Cisco IOS is up and running.
Yellow ROMmon is booting up, ROMmon detects a fatal hardware error, or ROM-mon is hanging before the system completes the bootup process.
Off ROMmon has completed the bootup process and the system either is in the autoboot stage or is waiting for a user command at a rommon#> prompt, or the NSE is off.
STANDBY Green On The NSE is the standby NSE in a High Availability configuration.
Off The NSE is not running or is running as the primary NSE.
GIGABIT ETHER-NET 0 LINK
Green/Yellow Green Gigabit Ethernet port 0 is up.
Yellow Gigabit Ethernet port 0 line protocol is down due to a link error or other conditions.
Off Default state on power up, Gigabit Ethernet port 0 has been administratively shut down, or a fatal hardware error has occurred.
GIGABIT ETHER-NET 1 LINK
Green/Yellow Green Gigabit Ethernet port 1 is up.
Yellow Gigabit Ethernet port 1 line protocol is down due to a link error or other conditions.
Off Default state on power up, Gigabit Ethernet port 1 has been administratively shut down, or a fatal hardware error has occurred.
1-4Cisco 7304 Installation and Configuration Guide
78-13279-01 B0
Chapter 1 Overview Hardware Overview
LEDs on the NPE-G100NPE-G100 LED information is in Figure 1-4 below.
GIGABIT ETHER-NET 2 LINK
Green/Yellow Green Gigabit Ethernet port 2 is up.
Yellow Gigabit Ethernet port 2 line protocol is down due to a link error or other conditions.
Off Default state on power up, Gigabit Ethernet port 2 has been administratively shut down, or a fatal hardware error has occurred.
GIGABIT ETHER-NET 3 LINK
Green/Yellow Green Gigabit Ethernet port 3 is up.
Yellow Gigabit Ethernet port 3 line protocol is down due to a link error or other conditions.
Off Default state on power up, Gigabit Ethernet port 3 has been administratively shut down, or a fatal hardware error has occurred.
DISK 0 Green/Yellow Green CompactFlash Disk is being accessed.
Yellow CompactFlash Disk access failure.
Off Default state on power up.
FE Management Port LINK
Green/Yellow Green Fast Ethernet physical link is up, line protocol is up.
Yellow Line protocol is down due to a link error.
Off Default state on power up or has been administratively shut down.
LED Label Color State Function
1-5Cisco 7304 Installation and Configuration Guide
78-13279-01 B0
Chapter 1 Overview Hardware Overview
Figure 1-4 LEDs on the NPE-G100
No. LED Label LED Purpose Color LED Color Status
1 Active Active Indicates this NPE-G100 is the active NPE
Green Solid green when this NPE is the active NPE.
Off Off when this NPE is not the active NPE.
2 Standby Standby Indicates this NPE-G100 is the redundant or secondary NPE
Green Solid green when this NPE is the standby NPE.
Off Off when this NPE is not active.
3 System-Up System-Up System status Green Green when Cisco IOS is up and running.
Amber • When ROMmon is booting up
• When ROMmon is hanging before the system completes the bootup process
• When ROMmon detects a fatal hardware error
Off Between amber when ROMmon is booting, and solid green when Cisco IOS is up and running.
4 LINK (Interfaces 0, 1, 2)
RJ-45 and SFP ports
— Green On, indicating that a link has been established.
Off Off when LINK is not up.
5 EN (Enable) (Interfaces 0, 1, 2)
RJ-45 ports only — Green On if the RJ-45 port is selected.
Off Off if the SFP port is selected.
6 Disk 0 CompactFlash Disk — Green Solid green when the disk is being used.
Blinking when the disk is being accessed.
DISK 0
LINK
GIGABIT ETHERNET 1
EN
RXSFPTX
RJ45 LINK
GIGABIT ETHERNET 1
EN
RXSFPTX
RJ45
CONSOLEAUX
ACTIVE
NETWORK PROCESSOR ENGINE 100
LINK
GIGABIT ETHERNET 1
EN
RXSFPTX
STANDBYSYSTEM-UP
C7304-NPE-G100
RESET
RJ45
8484
4
2
6
1 43 5
4 54 5
1-6Cisco 7304 Installation and Configuration Guide
78-13279-01 B0
Chapter 1 Overview Hardware Overview
Rear View
Figure 1-5 Cisco 7304 Router—Rear View
The rear of the Cisco 7304 router has two fan airflow vents. (See Figure 1-5.)
Two replaceable internal fans draw cooling air out of the chassis and across internal components to maintain an acceptable operating temperature. (See Figure 1-5.) The two fans are located at the rear of the chassis.
5770
6
INPUTOK FAN
OK
INPUTOK
–48V to –60 V16A
FANOK
OUTPUTFAIL
1-7Cisco 7304 Installation and Configuration Guide
78-13279-01 B0
Chapter 1 Overview Hardware Overview
System Board NSE–100Internally, the NSE-100 contains the following components:
• 256 or 512 MB SDRAM memory1
• Processors
– Reduced instruction set computing (RISC) RM7000 microprocessor that operates at an internal clock speed of 350 Mhz. The RM7000 processor maintains and executes the system management functions for the Cisco 7304 router. The processor also performs some memory and environmental monitoring functions.
– The Parallel eXpress Forwarding (PXF) processors enable parallel IP multipacket processing functions, working with the Route Processor to provide accelerated packet switching, as well as accelerated IP Layer 3 feature processing.
• System controller
The system controller provides hardware logic to interconnect the processors and SDRAM. The Cisco 7304 router has one system controller.
• Cache memory
The processor has three levels of cache: primary and secondary cache that are internal to the microprocessor with secondary unified cache for data and instruction, and tertiary, 2-MB external cache.
• Four environmental sensors for monitoring the internal temperature of the cooling air as it leaves the chassis
• Upgradeable boot ROM for storing sufficient code for booting the Cisco IOS software
System Board—NSE-150Internally, the NSE-150 contains the following components:
• 2 GB SDRAM
• Processors
– Route Processor that maintains and executes the system management functions for the Cisco 7304 router.
– The Parallel eXpress Forwarding (PXF) processors enable parallel IP multipacket processing functions, working with the Route Processor to provide accelerated packet switching, as well as accelerated IP Layer 3 feature processing.
• 2 MB NVRAM for storing the system configuration and environmental monitoring logs. NVRAM uses a lithium battery to maintain its contents when disconnected from power.
• Internal Flash Disk drive (bootdisk:) in addition to the external Flash Drive (disk0:)
• Upgradeable boot ROM for storing sufficient code for booting the Cisco IOS software
• Four environmental sensors for monitoring the internal temperature of the cooling air as it leaves the chassis
1. On November 3, 2003, the 512 MB SDRAM memory option became the default SDRAM memory option for the NSE-100 Processor. The 256 MB SDRAM memory option is still available as a spare, but the 128 MB SDRAM memory option that was once available for the NSE-100 Processor became unavailable for the NSE-100 Processor.
1-8Cisco 7304 Installation and Configuration Guide
78-13279-01 B0
Chapter 1 Overview Hardware Overview
System Board—NPE-G100Internally, the NPE-G100 contains of the following components:
• BCM 1250 processor system:
– Microprocessor operates at an internal clock speed of 800 Mhz.
– Hardware logic to interconnect the processor, dual double data rate synchronous dynamic random-access memory (DDR-SDRAM), hypertransport (HT) interface, the generic PCI bus, and the two midplanes.
– Cache memory—The NPE-G100 has two levels of cache: primary and secondary cache that are internal to the BCM 1250 processor system with secondary unified cache for data and instruction.
• DDR-SDRAM for providing code, data, and packet storage.
• Three environmental sensors for monitoring the cooling air as it enters, moves across the system board, and leaves the chassis.
• Three Gigabit Ethernet interfaces (six connectors: three Gigabit Ethernet SFP [optical] and three 10/100/1000 RJ-45 [copper]). For each interface, either the Gigabit Ethernet SFP or the RJ-45 port is available. The ports are linked directly to the BCM 1250 processor system.
• CompactFlash Disk: Stores sufficient code for booting the Cisco IOS boot loader image (bootdisk:).
• NVRAM for storing the system configuration and environmental monitoring logs. NVRAM uses a lithium battery to maintain its contents when disconnected from power.
• Upgradeable boot ROM for storing the ROMmon image and upgrading the system to newer versions of the ROMmon image. There are two upgradeable boot ROMs for storing the ROMmon image.
• Non-upgradeable boot ROM provides a “golden copy” of the default ROMmon image.
• Auxiliary port with full data terminal equipment (DTE) functionality.
• Console port with full data communications equipment (DCE) functionality.
• ECC (error correction code) system memory and internal L2 cache support.
System Management FunctionsThe Cisco 7304 performs the following system management functions:
• Sending and receiving routing protocol updates
• Managing tables, caches, and buffers
• Monitoring interface and environmental status
• Providing Simple Network Management Protocol (SNMP) management
• Booting and reloading images
• Managing line cards (including recognition and initialization during online insertion and removal)
• High availability (HA) support and management for two NPE-G100s, one active and one standby
• Routing and forwarding traffic
Caution Two NPE-G100s, two NSE-100s, or two NSE-150s are supported in the Cisco 7304. You cannot use two different processors in the same router, however.
1-9Cisco 7304 Installation and Configuration Guide
78-13279-01 B0
Chapter 1 Overview Checking the Shipping Container Contents
Note For a chassis footprint, additional dimensions, and clearance requirements for the Cisco 7304 router, see the “Preparing to Install the Cisco 7304 Router” section on page 2-1 in Chapter 2, “Installation and Maintenance.”
The Cisco 7304 router supports multiprotocol, multimedia routing and bridging with a wide variety of protocols and line cards.
Checking the Shipping Container ContentsUse the Cisco 7304 Components List to check the contents of the Cisco 7304 router shipping container. Do not discard the shipping container. You need the container if you move or ship the Cisco 7304 router in the future.
Note We no longer ship the entire router documentation set automatically with each system. You must specifically order the documentation as part of the sales order. If you ordered documentation and did not receive it, we will ship the documents to you within 24 hours. To order documents, contact a customer service representative.
Installation ChecklistTo assist you with your installation and to provide a historical record of what was done by whom, photocopy the Cisco 7304 Router Installation Checklist, Table 1-4 on page 1-11. Indicate when each procedure or verification is completed. When the checklist is completed, place it in your site log along with the other records for your new router.
Table 1-3 Cisco 7304 Components List
Component Description Received
Chassis Cisco 7304 chassis configured with an AC or DC power supply, line cards, and a CompactFlash Disk
Accessories:
• Rack-mount and cable-management kit
• Power cables
• Documentation
The following accessories might arrive in separate shipping containers:
Two rack-mount brackets, two cable-management brackets, four M4 x 20-mm Phillips flathead screws. Eight 8-18 x .37-in. screws for a 19-inch rack; 8 x .755-in. screws for a 21-inch–23-inch rack
An AC power cable, if an AC power supply was ordered
If ordered, router hardware and software documentation set and the Cisco Documentation CD-ROM package1
1. Titles and quantities of documents will vary. You must order the type and quantity of documentation sets when you order the hardware.
Optional Equipment Examples: Line cards, GBICs, SFP modules, network interface cables, transceivers, special connectors
1-10Cisco 7304 Installation and Configuration Guide
78-13279-01 B0
Chapter 1 Overview Installation Checklist
Table 1-4 Cisco 7304 Router Installation Checklist
TaskVerified By Date
Date router received
Router and all accessories unpacked
Safety recommendations and guidelines reviewed
Types and numbers of interfaces verified
Installation Checklist copied
Site log established and background information entered
Site power voltages verified
Site environmental specifications verified
Required passwords, IP addresses, device names, and so on, available
Required tools available
Network connection equipment available
Router mounted in rack (optional)
Cable-management brackets installed (optional but recommended)
AC power cable(s) connected to AC source(s) and router
DC power cable(s) connected to DC source(s) and router
I/O ports operational
Line card or PCI port adapters are operational
Network interface cables and devices connected
ASCII terminal attached to console port
Console port set for 9600 baud, 8 data bits, no parity, and 2 stop bits (9600 8N2)
System power turned on
System boot complete (SYSTEM–UP LED is on)
Correct hardware configuration displayed after system banner appears
1-11Cisco 7304 Installation and Configuration Guide
78-13279-01 B0
Chapter 1 Overview Installation Checklist
1-12Cisco 7304 Installation and Configuration Guide
78-13279-01 B0