13
OXYGEN™ Cabinet Integration Guide for Player Tracking and Online Components Location of Components, Mounting Areas and Connectors Pinout Rev. 1.2 June 2010

OXYGEN™ Cabinet - Integration Guide for Player Tracking and Online Components 1.2

Embed Size (px)

DESCRIPTION

Atronic

Citation preview

  • OXYGEN Cabinet

    Integration Guide for Player Tracking and Online ComponentsLocation of Components, Mounting Areas and Connectors Pinout

    Rev. 1.2

    June 2010

  • 2OXYGEN Cabinet - Integration Guide for Player Tracking and Online Components

    Release Info / Disclaimer

    OXYGEN CabinetIntegration Guide for Player Tracking and Online Components

    Location of Components, Mounting Areas and Connectors Pinout

    Rev. 1.2Rel. June 2010

    Copyright Notice: 2010, ATRONIC. All rights reserved.No part of this publication may be copied or distributed, transmitted, transcribed, stored in a retrieval system, or translated into any human or computer language, in any form or by any means, electronic, mechanical, magnetic, manual, or otherwise, or disclosed to third parties without the express written permission obtained from a properly authorized official of ATRONIC.

    DISCLAIMERATRONIC makes no representation or warranties, express or implied, with respect to this publication, or any product of ATRONIC, including but not limited to warranties of merchantability or fitness for any particular purpose. ATRONIC reserves the right to make changes, enhancements, revisions and altera-tions of any kind to this publication or the product(s) it covers without obligation to notify any person, institution or organization of such changes, enhancements, revisions and alterations.

    TRADEMARKSThis document may contain trademarks of ATRONIC. All other brand and product names are trademarks or registered trademarks of their respective companies.

  • 3OXYGEN Cabinet - Integration Guide for Player Tracking and Online Components

    Table of ContentsRelease Info / Disclaimer . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2

    1. Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41.1 About this Manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

    2. Available Mounting Areas . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52.1 Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52.2 Player Tracking Bracket . . . . . . . . . . . . . . . . . . . . . . . . . . 62.3 SMIB Bracket . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62.4 Cable Routing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

    3. Peripheral Board . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83.1 Accounting System Connectors Pinout . . . . . . . . . . . . . . . . 9

    4. SAS Channel Setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10

    5. Manufacturing Drawings . . . . . . . . . . . . . . . . . . . . . . . . . . . . 135.1 Generic Player Tracking Bracket . . . . . . . . . . . . . . . . . . . . 13

  • 4OXYGEN Cabinet - Integration Guide for Player Tracking and Online Components

    1. Introduction

    Introduction1.

    About this Manual1.1

    Scope1. This document is to inform your company of the upcom-ming release (May 2010) of the new ATRONIC OXYGEN cabi-net, which will require a custom designed bracket to accomo-date your player tracking components.

    2. This document is intended to provide manufacturers of player tracking and online equipment with the data required to integrate and build - custom designed player tracking brackets- SMIB solutions to connect to the floor network- the required cables and accessories.

    Important: ATRONIC will not provide custom-ized cables and/or accessories to connect the equipment listed above. Manufacturers of player tracking and online equipment are responsible to provide such equipment. Exceptions require an ex-plicit request including account of expenditures.

    Target AudienceWe address manufacturers of player tracking components, player tracking brackets and other online system components. Further we address service technicians involved in online sys-tem installations.

    NomenclatureOXYGEN is the name of the new cabinet featuring two 22 wide screen monitors.

    sensys EP is the electronic platform used in the OXYGEN cabinet.

    diversity is the name of the new ATRONIC multi-game soft-ware available on OXYGEN/sensys EP.

    ATRONIC OXYGEN Cabinet

  • 5OXYGEN Cabinet - Integration Guide for Player Tracking and Online Components

    2. Available Mounting Areas

    Available Mounting Areas2.

    Overview2.1

    This figure shows an overview of the available mounting areas on the player tracking bracket and the SMIB bracket, and the location of the Peripheral Board and and the power outlets.

    SMIB Bracket

    Player Tracking Bracket

    Peripheral Board

    115/230V AC Power Outlets

  • 6OXYGEN Cabinet - Integration Guide for Player Tracking and Online Components

    Player Tracking Bracket2.2

    This figure shows the available mounting area for components on the player tracking bracket. A drawing of a generic player tracking bracket is available in chapter 5. Manufacturing Drawings.

    SMIB Bracket2.3

    This figure shows the available mounting area for components on the SMIB bracket.

    349

    100

    50

    463

    231,5

    81

    Visible area

    Front View

    349

    ca. 1

    65

    ca. 1

    35

    7575

    150

    for printer

    for printer

    Available mounting area

    Available mounting area

    AvailableMountingArea

    298

    208

    250

    70

    165Available mounting area

    Available mounting area

    2. Available Mounting Areas

    Note: Make sure that cables outside the boudaries do not in-terfere with the SMIB bracket.

    Note: Make sure that cables outside the boudaries do not in-terfere with compo-nents on the Player Tracking Bracket.

  • 7OXYGEN Cabinet - Integration Guide for Player Tracking and Online Components

    Cable Routing2.4

    This figure shows the suggested cable routing for player tracking components.

    Yellow = Signal and low voltage cableRed = Network cable and other cables to be routed out of the machineBlack = 115/230V power cable (always on; the internal power outlets are not switched by the machine)

    2. Available Mounting Areas

  • 8OXYGEN Cabinet - Integration Guide for Player Tracking and Online Components

    Peripheral Board3. Online system components such as Smart Interface Bords (SMIB) and similar equipment have to be con-nected to the ATRONIC Peripheral Board.

    The figure below shows the main connections to connect SAS based online equipment. The connection intended for accounting systems is splitted into two connectors. It provides SAS channel 1 and the door connectors.

    3. Peripheral Board

    SAS Channel 1(+ Door Connectors)

    SAS Channel 3

    SAS Channel 2

    Note: See next page for connectors pinout

    Perip

    hera

    l Boa

    rd

  • 9OXYGEN Cabinet - Integration Guide for Player Tracking and Online Components

    Accounting System Connectors Pinout3.1

    The accounting system connection (SAS channel 1) is split into two connectors P220 and P221.

    Accounting System / Con. 1 (Peripheral Board Connector P220)

    1 +5V2 +12V3 COM 0 / RS232 RxD4 COM 0 / RS232 TxD5 Bill Door - Normally Close6 Bill Door - Common7 Bill Door - Normally Open8 Drop Door - Normally Close9 Drop Door - Common10 Drop Door - Normally Open11 Logic Door - Normally Close12 Logic Door - Common13 Logic Door - Normally Open14 Ground

    Recommended Connector:Molex 22-01-3147, Crimp Terminal 08-52-0123or Tyco 1-770602-4, Crimp Terminal 770666-1

    The connections for SAS channels 2 and 3 come as a D-Sub 9 male connector (serial connector).

    SAS Channel 3(Peripheral Board Connector P210)

    1 NC2 COM 4 / RS232 RxD3 COM 4 / RS232 TxD4 +5V5 Ground6 NC7 +12V8 NC9 NC

    Cable LenghtRecommended cable length to connect player tracking components located on the inside of the main door to the Peripheral Board is approximately 1,50 - 2,00 meters.

    1 14 Accounting System / Con. 2 (Peripheral Board Connector P221)

    1 Main Door - Normally Close2 Main Door - Common3 Main Door - Normally Open4 Bill Stacker Door - Normally Close5 Bill Stacker Door - Common6 Bill Stacker Door - Normally Open7 Belly Door - Normally Close8 Belly Door - Common9 Belly Door - Normally Open10 Door 5 - Normally Close11 Door 5 - Common12 Door 5 - Normally Open

    Recommended Connector:Molex 22-01-3127, Crimp Terminal 08-52-0123or Tyco 1-770602-2, Crimp Terminal 770666-1

    SAS Channel 2(Peripheral Board Connector P206)

    1 NC2 COM 1 / RS232 RxD3 COM 1 / RS232 TxD4 +5V5 Ground6 NC7 +12V8 NC9 NC

    1 12

    11

    66

    11

    66

    3. Peripheral Board

  • 10OXYGEN Cabinet - Integration Guide for Player Tracking and Online Components

    SAS Channel Setup4. Note: This section is intended as an additional source of infor-mation to understand the functionality in general. For detailed information please refer to the Software Manual relevant for a particular software version.

    During basic software configuration (Initial Setup) the SAS Channel Setup menu allows to

    - Set the SAS address of the machine - Allocate SAS polls to SAS channels 1, 2 or 3. - Change the attributes for communication down and handpay buffer full events.

    To configure the SAS Channel Setup table, select a field and touch the Modify button. The Modify button toggles through the available options or opens a number pad.

    Enable/DisableaChannel: Select the Enabled/Disabled field of a channel and touch

    the Modify button to generally enable or disable a SAS channel.

    EGMAddress: Configures the SAS machine address on this SAS channel.

    Control: Allocate the control polls to one of the channels. Control

    polls can not be disabled on all channels.

    AFTTransfers: Allocate the polls for AFT transfers to one of the channels

    or disable them on all channels.

    Note: To disable AFT in general, adjust the AFT Transfers set-ting to disabled on all enabled channels.

    LegacyBonus: Allocate the legacy bonusing polls to one of the channels.

    Ticketing: Allocate the polls and exceptions for ticketing to one of

    the channels or disable them on all channels.

    TicketReporting: This entry allows to send ticket reporting polls on addi-

    tional channels for reporting purposes.

    - continued on next page -

    Note: In most case the actual SAS ma-chine address is provided by a connect-ed Smart Interface Board (SMIB). In this case set the EGM Address to 1.

    4. SAS Channel Setup

    SAS Channel Setup - default settings

    SAS Channel Setup - modified settings (example)

  • 11OXYGEN Cabinet - Integration Guide for Player Tracking and Online Components

    4. SAS Channel Setup continued

    CommunicationDownAction: This entry defines the handling if communication to the

    host system is lost on this channel.

    Lock EGM (default):If communication to the host system is lost for more than 15 seconds, the machine locks.

    Ignore:The machine ignores a loss of communication to the host system and remains playable.

    HandpayReporting: This entry defines the handpay buffer handling.

    Secure (default):If the handpay buffer is full, the machine locks up until the pending handpay polls are read by the accounting system.

    Overwrite:If the handpay buffer is full, the oldest entries will be overwritten and the machine remains playable. This handling is intended for EGMs connected to an ac-counting system that does not read handpay polls and for EGMs not connected to an accounting system at all.

    4. SAS Channel Setup

  • 12OXYGEN Cabinet - Integration Guide for Player Tracking and Online Components

    - blank page -

  • 13OXYGEN Cabinet - Integration Guide for Player Tracking and Online Components

    5. Manufacturing DrawingsDrawings are also available as a file. Please contact ATRONIC.

    Generic Player Tracking Bracket5.1

    4,5

    6,5 (4x)5 (5x)

    13,5 (2x)

    10 free of nish (3x)

    0 8,5 (2x)

    91,5 (2x)

    0

    8 (2x)

    92 (2x)50

    15 (2x)

    85 (2x)

    100

    90 (2x)

    3,5 (2x)

    0

    721,3 (2x)

    47,5 (2x)39,5

    6,3

    226,5231,5236,5

    456441,8 (2x)

    415,5 (2x)423,5

    463

    24,5 (2x)

    11,5 (2x)

    visible side

    Notes:

    - Draw

    ing is in 1st angle projection - Break all sharp edges - Part m

    ust be RoHS com

    pliant - Sheet thickness = 1.5m

    m - M

    ax. bend Radius = sheet thickness - U

    ndimensioned radii = 2m

    m

    OXYGEN Cabinet - Integration Guide for Player Tracking and Online ComponentsRelease Info / Disclaimer1. Introduction1.1 About this Manual

    2. Available Mounting Areas2.1 Overview2.2 Player Tracking Bracket2.3 SMIB Bracket2.4 Cable Routing

    3. Peripheral Board3.1 Accounting System Connectors Pinout

    4. SAS Channel Setup5. Manufacturing Drawings5.1 Generic Player Tracking Bracket