Wednesday, December 07, 2016
PA-100M
Report on the inspection for compliance with
Temperature Range Operation
- Low Temperature Test -
Name Date Signature
Conducted by: Valentin Ladizhensky 05/12/2016
Approved by: Dimitry Ginzburg 06/12/2016
Date: December,
2016
Report on the inspection for compliance with
Temperature Range Operation
R&D Department
Edition: 001 PA-100M
Page 2 of 12 RD-4-16-137 Ver.1.0
Page 2 of 12
Contents
1. Scope………….……………………………………………………….4
2. Reference………………………………………………………………5
3. Test Instrumentation…………………………………………………….5
4. Test procedures ………….…………………………………………5
5. Results………………………………………………………………….9
Date: December,
2016
Report on the inspection for compliance with
Temperature Range Operation
R&D Department
Edition: 001 PA-100M
Page 3 of 12 RD-4-16-137 Ver.1.0
Page 3 of 12
This Page Is Left Blank
Date: December,
2016
Report on the inspection for compliance with
Temperature Range Operation
R&D Department
Edition: 001 PA-100M
Page 4 of 12 RD-4-16-137 Ver.1.0
Page 4 of 12
1. Scope
Purpose.
- These tests are conducted in addition to the inspection for compliance with United
States Military Standards MIL-STD-810E (Meth 501.3/502.3 Procedure II.)
- The reason for additional test is due to a fail at low temperatures (-10°C). Details are
described in Reports No: 20160918-1605 by “QualiTech Compliance Engineering
Environmental & Mechanical Lab”., and Report “RAM R-200&PA-100&RP-10 TEST
REPORT_001_DG” by Rotem Industries Ltd.
1.1. Equipment under test:
- PA-100M – Alpha Detector contains atmospheric cells made of aluminium containing
a thin anode wire. The surface of the cell is a membrane of aluminized Mylar, protected
by a fine stainless steel wire mesh.
- RAM R-200 - This Monitor connect with the two above-mentioned detectors (PA-100
and RP-10). RAM-R-200 is portable multifunctional, rugged survey meter designed for
measuring wide range gamma radiation fields and contamination. The RAM R-200
along with its internal detectors is waterproof to a depth of 1 meter.
- RAM R-200 Detector Cable: This is a special cable for connection between the
Monitor and Detectors.
1.2. Specification of Detector PA-100M:
- Temperature Range Operation: -10°C to +50°C
- Accuracy ± 15%
Date: December,
2016
Report on the inspection for compliance with
Temperature Range Operation
R&D Department
Edition: 001 PA-100M
Page 5 of 12 RD-4-16-137 Ver.1.0
Page 5 of 12
Table 1. Detectors under Test
Note: UUT-1 using the PA-100M after repair, with the old version software. Registered
instability in operation under normal conditions.
Date: December,
2016
Report on the inspection for compliance with
Temperature Range Operation
R&D Department
Edition: 001 PA-100M
Page 6 of 12 RD-4-16-137 Ver.1.0
Page 6 of 12
2. References
- Reports No: 20160918-1605 by “QualiTech Compliance Engineering Environmental
& Mechanical Lab”
- Report “RAM R-200&PA-100&RP-10 TEST REPORT_001_DG” by Rotem
Industries Ltd.
3. Test Instrumentation
TEMPERATURE CHAMBER
- Programmable H/L Temp.Tester Chamber
Model: FC-60P, -20/+150[°C], S/N: 200808001, manufacture “MRC”
4. Test Procedure
UUT-1 and UUT-2 tested inside the Chamber with source Torium-232
Fig.4.1. Temperature profile during Temperature Operation Test
Date: December,
2016
Report on the inspection for compliance with
Temperature Range Operation
R&D Department
Edition: 001 PA-100M
Page 7 of 12 RD-4-16-137 Ver.1.0
Page 7 of 12
Table.4.1. Temperature profile
- After stabilization at each temperature step three readings were recorded.
- The average of these readings was calculated and presented in the results section.
Date: December,
2016
Report on the inspection for compliance with
Temperature Range Operation
R&D Department
Edition: 001 PA-100M
Page 8 of 12 RD-4-16-137 Ver.1.0
Page 8 of 12
Pic.4.1.1. UUT inside the Chamber.
Date: December,
2016
Report on the inspection for compliance with
Temperature Range Operation
R&D Department
Edition: 001 PA-100M
Page 9 of 12 RD-4-16-137 Ver.1.0
Page 9 of 12
Pic.4.1.2. Programmable H/L Temp.Tester Chamber. UUT inside Chamber.
Date: December,
2016
Report on the inspection for compliance with
Temperature Range Operation
R&D Department
Edition: 001 PA-100M
Page 10 of 12 RD-4-16-137 Ver.1.0
Page 10 of 12
5. Results
5.1. Checking prior to the test.
All instruments have been tested in the chamber in a stable geometry before starting
Temperature testing at room temperature +24°C.
Table. 5.1. Pre-Test (Before the start of stage of tests Temperature Operation)
Date: December,
2016
Report on the inspection for compliance with
Temperature Range Operation
R&D Department
Edition: 001 PA-100M
Page 11 of 12 RD-4-16-137 Ver.1.0
Page 11 of 12
5.2. Operation Temperature
Table 5.2. Results of Temperature Operation Test
- UUT-1 (PA-100M S/N: n/a) – on Temperature 5°C Accuracy is unacceptable, the
deviation continues to increase in proportion to the decrease in temperature. Normal
operation on temperature greater than 10°С.
- UUT-2 (PA-100M S/N: 9615-006) – on Temperature -5°C Accuracy is 20%.
The deviation continues to increase in proportion to the decrease in temperature.
Specificated operation on temperature greater than -5°С.
6. Conclusion
According to the obtained results it is suggested to modify the Operation
Temperature range of the PA-100M Detector to be the following:
-5°C to +50°C (20% Temperature dependence)
Date: December,
2016
Report on the inspection for compliance with
Temperature Range Operation
R&D Department
Edition: 001 PA-100M
Page 12 of 12 RD-4-16-137 Ver.1.0
Page 12 of 12
END OF REPORT