24
A People Electric Appliance serves for people. PANEL METER ISO14001 OHSAS18001 ISO9001

PANEL METER - PEOPLE ELE.APPLIANCE GROUP … · MOVING COIL INSTRUMENTS DC VOLTMETERS PANEL METER ... If used with CT, the secondary current 5A or 1A is standard. ... 1A,5A for use

Embed Size (px)

Citation preview

A

People Electric Appliance serves for people.

PANEL METER

• ISO14001 OHSAS18001ISO9001

PE-L96, 72, 48

PE-T80, 780, 670, 60

AC Ammeter

~

AC Voltmeter

1 2

3

1 2

3

1 2

3

1 2

3

AC Ammeter AC Voltmeter

PE-C96, 72, 48

PE-T80, 780, 670, 60

PE-C96, 72, 48

PE-C80, 780, 670, 60

PE-C96, 72, 48

PE-C80, 780, 670, 60

PE-F96, 80,72, 48

PE-E80,780,670,60

Hz meter

PE-R96,72

two rows of reeds type

frequency meter

PE-S96,72

Three phase

Synchroscope

PANEL METER

IEC51, IEC61010-1, VDE410, BS89, UL94, NE60051, IEN43780

The insulation test is carried out at a voltage of 2KV, 50Hz 1min and applies for instruments with the full scale deflection up to650V. Other standards comply with IEC61010-1.

CASES:All cases at least dust and splash water-proof.All cases are made of strengthened self-extinguishing PPOWith a high hit-resistance and a maximum electric isolation

ACCURACY CLASS:AC, DC Voltmeters and Ammeters comply with the accuracyclass 1.5.The power meters comply with accuracy class 1.5.The frequency meters comply with accuracy class 1.0.The maximum-demand meters comply with accuracy class 3.0.The power factor meters and synchroscope meter complywith accuracy class 2.5.

INSULATION TEST:

All instruments operate trouble-free at room temperature rang-ing from -25 to + 40 .The Max. Voltage to earth Voltmeter-The upper range voltage(full scale deflection)Ammeter-The Voltage of the main power supply.The meter use d shall be keep cleaning.The user shall be made aware of that, if the me ter is used in a manner not specified by the manufacturer,the protection provided by the meter may be impaired.

TEMPERATURE INFLUENCE:

MOUNTING ANGLE:The instruments are calibrated for vertical mounting, unless otherpositions such as horizontal or inclined at any specified angle to thehorizon. Can be provided upon request(in this case, specify angle ofinclination, please) The accuracy class refers to the specified mounting angle only.

STANDARDS:

1 2

3

~ A B C

L1L2L3

A B C

AO BO

• A-01

~

L1

L2

L3

2 5

1 3

L1

L2

L3

1 3

2 4

5 6 7

PE-M96, 80,72, 48

Maximum demand meter

PE-PF96, 80,72, 48

PE-PF80, 780, 670, 60

3 Phase Power factor meter

PE-W(Var)96, 80,72, 48

PE-W80, 780, 670, 60

Three phase three wire active

power and reactive Power meter

without voltage transformers

1 2

3 4

5 6 7

L

N

~L

N

~

1

2

3

4

5 6 7

L1

L2

L3

PE-W(Var)96, 72, 48PE-W(Var)80, 780, 670, 60Single~phase Power meterwith Current transformers

PE-W(Var)96, 72, 48PE-W(Var)80, 780, 670, 60Single~phasePower meter with Current and Voltage transformers

PE-W(Var)96, 72, 48PE-W(Var)80, 780, 670, 60Three phase three wire ActivePower and Reactive Power meter withcurrent and voltage transformers

2 5L N

~L N

A B C

A B

PE-S96, 72

Single phase

Synchroscope

PE-PF96, 80, 72, 48

PE-PF80, 780, 670, 60

Single phase power factor meter

PANEL METER

• A-02

Model: PE-T96, PE-T72, PE-T48, PE-C96, PE-C72, PE-C48Accuracy: Class 1.5Specs: 0.1A,0.5A,1A,1.5A,3A,5A,7.5A,10A,20A,25A,30A,50A,75,100A(use Ext. CT 5A)Note: For 60/75/100A direct meter, the class in 2.5.Advantage: The scale can be easily changed without opening the front frame so that the class will not be influenced.

MOVING IRON & MOVING COIL INSTRUMENTS AC AMMETER

Model:PE-T96, PE-T72, PE-T48, PE-C96, PE-C72, PE-C48Accuracy: Class 1.5Specification:30V, 50V,75V, 100V, 120V, 150V, 250V, 300V, 450V, 600V(For 450-380KV, should be used with potential transformer whose secondaryvoltage 100V).

MOVING IRON & MOVING COIL INSTRUMENTS AC VOLTMETERS

Model: PE-C96, PE-C72, PE-C48Accuracy: Class 1.5Specification:25uA, 30uA, 50uA, 1mA, 2mA, 5mA, 10mA, 20mA, 30mA, 50mA, 75mA, 100mA, 150mA, 200mA, 250mA, 300mA, 500mA, 1A, 3A, 5A, 7.5A, 10A, 20A,30A, 50A, 75,100A(used with Shunt)Note: For 60/75/100A direct meters, the class in 2.5.Advantage: The scale can be easily changed without opening the front frameso that the class will not be influenced.

MOVING COIL INSTRUMENTS DC AMMETER

Model: PE-C96, PE-C72, PE-C48Accuracy: Class 1.5Specification: 3V, 5V, 7.5V, 10V, 15V, 20V, 30V, 50V, 75V, 100V, 120V, 150V,200V, 250V, 300V, 400V, 450V, 600V,Note: Over 6000V should be used with Ext. Resistor. (Rated current 5mA).

MOVING COIL INSTRUMENTS DC VOLTMETERS

PANEL METER

PE-96

PE-96

PE-96

PE-96

• A-03

Model: PE-F96, PE-F72, PE-F48Accuracy: Class 1.0Volt: 50V,100V, 220V, 380VFreq:44-55Hz, 45-65Hz, 55-65Hz, 47-53Hz, 57-63Hz, 44-56Hz, 54-66Hz, 450-550Hz, 550-650Hz

MOVING COIL INSTRUMENTS FREQUENCY METER POINTER TYPE

Model: PE-F96, PE-F72, PE-F48these meters can measure the other non-electric values: temperature, speed,and so on. Heat resistance: Case of non-combustible plastic material accord-ing to UL-94 V0.Fastening: By means of nuts, absolutely safe, fast, robust, side-by-side

MOVING COIL INSTRUMENTS FOR NON-ELECTRIC VALUES

One row of reeds Model: PE-R96-1, PE-R72-1Two rows of reeds Model: PE-R96-2, PE-R72-2Accuracy: Class 0.5Specification:Voltage: 50V 100V 220V 380V 440V 415VFrequency: 45~55Hz, 45~65Hz, 55~65Hz, 47~53Hz, 57~63Hz, 44~56Hz, 54~66Hz, 450~550Hz, 450~650Hz, 550~650HzThis vibrating reed frequency meter with one row of horizontal reeds or with two rowsof horizontally arranged reeds for connection to one main voltage. Vertical arrangementson requestHeat resistance: Case of non-combustible plastic material.Changeable scale: All scales with printing technique.The dial plate with different scale, which is at the same internal value, can be changeable.But the accuracy is unchangeable.Fastening: By means of nuts, absolutely safe,fast,robust,sibe-by-side.Mounting depth: Max.43mm.

FREQUENCY METER WITH REEDS TYPES

PANEL METER

PE-96

PE-96

PE-96

• A-04

For 3 phases circuits, balanced load 45-65Hz and for 1 phase AC 50Hz.Model: PE-PE96,PE-PF72Accuracy: Class 2.5Voltage:100V,380V,440VFrequency:50Hz,60HzScale graduation:0.5cap-1-0.5ind,0.3cap-1-0.7ind,0.4cap-1-0.4ind, 0.7cap-1-0.3indOrders to be noted:Type of Current: 1P,3P 3W circuits, balanced load.Rated Volt: The voltage is line voltage (between two wire).Operating Current: If used with CT, the secondary current 5A or 1A is standard.

POWER FACTOR METER

Wattmeters or Varmeters with build-in converter for 1 phase 3P 3W, 3P 4W.Model: PE-W96, PE-W72Accuracy: Class 1.5Voltage:50V,100V,220V,240V,220/380V,240/415VCurrent:5AThese meters are used with potential secondary voltage 100V voltage transformer orsecondary current 5A CT. Wattmeters with built-in converter for 3P 3W, 3P 4W andsingle phase.

POWER METER

Synchrony scope for phase comparison for three phase AC circuits, 50Hz or 60Hz.Model:PE-S96 PE-S72Specification:Voltage:100V 220V 380V 440VWorking time:15min max.

SYNCHROSCOPE METERS

This indicator is designed for easy testing of phase sequence in three-phase systemswith a permissible operating voltage up to 500V. For short connections, no longer than5 minutes for one test, a push-button switch is placed on the front plate. A disc with anindicating arrow rotates in the direction of the arrow, if the three phases are properlyconnected, otherwise the disc rotates in the other direction. By changing of two wires,the phase sequence will be corrected to corresponding designation of the terminals.Model:PE-SI 96 PE-SI72Specification:Voltage:110-550VWorking time:no longer than 5 minutes.

SEQUENCE INDICATOR

PANEL METER

PE-96

PE-96

PE-96

• A-05

Model: PE-L96V, PE-L80V, PE-L72V, PE-L48VSpecification: 0/90-110V, 0/100-120V, 0/200-240V, 0/340-420VHeat resistance: Case of non-combustible plastic material according to UL-94 V0.Fastening: By means of nuts, absolutely safe,fast,robust,sibe-by-side.Mounting depth: Max.43mm.

Model:PE-AM96 PE-AM72Features: For the cont rol of Maximum Demand and the monitoring and control of overload on distribution systems. Constructed with an electronic circuit and 5A relay. The alarm was set by the blue slim pointer, the red light is the alarm one, which can be used with buzzer.Accuracy: Class 3.0Rating: 1A,5A for use with separate CT.Burden: MDI2.2VA Frequency:50/60HzOverload: x1.2 continuous, 10 1 second, 20 1 second via5/5 CT.Relay CircuitAuxiliary: AC 220V 10%, 50/60Hz Burden:2.6VA Bestrews: 1%Time delay: 1 second approximately fixed. Alarm and Trip pointWorking Range:20-100% 1%added to the MDI AccuracyRelay: Single Pole ChangeoverRelay Rating: AC 250V 5A non inductive, DC 24V 2A ResistiveTemperature: -10 to+50

For measuring mean maximum current value, when it is 8min or 15min or 30min.Model: PE-M96 PE-M72Accuracy: Class3.0Specificat ion: 8min 5A, 15min 5A, 30min 5A, 8min 1A, 15min 1A(No specification for 30 min 5A for PE-M48)With bimetal movement and thermal delayed indicator for measuring the maximum mean load during a period of 8 or 15 minutes, eats red maximum pointer. Lead seal can protect resettingknob of maximum pointer. Response time 8 or 15,30 minutes(to be specified when ordering).Heat resistance: Case of non-combustible plastic material.Changeable sca le: All scales with printing technique. The dial plate with different scale which is at the same internal value can be changeable. But the accuracy is unchangeable.Fastening: By means of nuts, absolutely safe, fast, robust, side-by-side.Mounting depth: Max 43mm.

MAXIMUM DEMAND AMMETER

For measuring mean maximum content value and instantaneous values for combinedwith moving iron movement movement meters.Model:PE-2M96, PE-2M72Accuracy: Class3.0(instantaneous values)Class 1.5Specification:8min 5A,15min5A, 8min 1A,15min1AWith bimetal movement and thermal delayed indicator for measuring the maximum mean load during a period of 8 or 15 minutes, eats red maximum pointer. Lead seal can protect resettingknob of maximum pointer. Scale compressed at the beginning, convenient reading from 25% of full-scale deflection. Accuracy of maximum load indication3%. Referred to the maximum pointer. Response time 8 or 15,30 minutes(to be specified when ordering).Heat resistance: Case of non-combustible plastic material.Changeable scale: All scales with printing technique. The dial plate with different scale, whichis at the same internal value, can be changeable. But the accuracy is unchangeable.Fastening: By means of nuts, absolutely safe, fast, robust, side-by-side.Mounting depth: Max 43mm

COMBINED WITH MOVING IRON AMMETERS

MAXIMUM DEMAND INDICATOR WITH RELAY

MOVING COIL INSTRUMENTS FOR RATED VOLTMETERS

PANEL METER

PE-96

PE-96

• A-06

Model: PE-H96 PE-H72 PE-H48Display:99999.99Voltage:AC 100~125V,AC200~250V,AC380~440V,AC24VBurden:2.5VAFrequency:50/60HzFeatures: Elapsed Time Meters or Hours Run meters or Hours Run Meters monitor ON/RUN time of plant and equipment allowin g the user to perform functions such as Production Effici-ency Cost Estimating and Service Period monitor-ink for preventatives maintenance etc. Thetime is measured in instrument of 0.01h up to 99999.99 hours after which time the meterresets to zero. Non-reset table to prevent accidental resetting.

The instruments are suitable for measuring AC Ampere in 4 or 3 wire networks by using a change over switch on the front side of the instrument.Model: PE-T96A-S, PE-T72A-STechnical data:Movement: Moving-iron movement with oil filled bearings, practically vibration-free oildamping.Accuracy: Class 1.5Frequency range: 50Hz.Heat resistance: Case of non-combustible plastic material according to UL-94 V0.Measuring range: 0.1/1A, 0.2A/2A, 0.3A/3A, 0.4A/4A, 1A/10APosition: L1-L2,L1-L3,L2-L3.

The instrument are suitable for measuring AC Voltages in three phase 4 or 3 wire networks by using a change over switch on the front side of the instrument.Model: PE-T96V-S PE-T72V-STechnical data:Movement: Moving-iron movement with oil filled bearings, practically vibration-free oildamping.Class of accuracy: 1.5%Frequency range: 50Hz.3 phase 4 wire Measuring range: 60V/100V,80/150V 100/200V 150/250V, 250/400V 300/500V.Position:L1-L2,L1-L3,L2-L3,L1-N,L2-N,L3-NHeat resistance: Case of non-combustible plastic material according to UL-94 V0.3 phase 3 wire Measuring range: 100V,150V 200V 250V 400V 500VPosition: L1-L2,L1-L3,L2-L3.

Model: PE-C96, PE-C72, PE-C48these meters can measure the other non-electric values: temperature, speed, and so on.Heat resistance: Case of non-combustible plastic material according to UL-94 V0.Fastening: By means of nuts, absolutely safe, fast, robust, side-by-side

MOVING COIL AMMETERS WITH CHANGE OVER SWITCH FOR AC AMMETERS

MOVING IRON VOLTMETER WITH CHANGE OVER SWITCH FOR AC VOLTMETERS

MOVING COIL INSTRUMENTS FOR NON-ELECTRIC VALUES

ELAPSED TIME METER OR HOURS RUN METERS

PANEL METER

PE-96

PE-96

PE-96

• A-07

Model: PE-C96A PE-C72AAccuracy: Class 1.5Specification: 3V, 5V, 7.5V, 10V, 15V, 20V, 30V, 50V, 75V, 100V, 120V, 150V, 200V, 250V, 300V, 400VMeasuring ranges over 450V with external resistor(rated current 5mA)Heat resistance: Case of non-combustible plastic material according to UL-94 V0.Fastening: By means of nuts, absolutely safe, fast, robust, sibe-by-side.Mounting depth: Max.43mm.

Model: PE-C96A. PE-C72AAccuracy: Class 1.5Specification: 100uA 500uA 1mA 2mA 5mA 10mA 20mA 30mA 50mA 75mA 150mA200mA 250mA 300mA 500mA 1A 3A 7.5A 10A 20A 30A 50A 60A 100A. For 10A-10KA,useexternal 75mV, 65mV or 45mV shunt.Notes: For 50A 60A 75A 100A meters, when these meters directly connections circuit, their accuracy is class 2.5Heat resistance: Case of non-combustible plastic material according to UL V0.Changeable sca le: All scales with printing technique. The dial plate with different scale, which is at the same internal value, can be changeable. But the AC is unchangeable.Fastening: By means of nuts, absolutely safe, fast, robust, side-by-side.Mounting depth: Max.43mm.

MOVING COIL INSTRUMENTS(240DEG) DC AMMETERS

MOVING COIL INSTRUMENTS(240 DEG) DC VOLTMERS

Model: PE-L96A, PE-L72AAccuracy: Class 1.5Specification: 0.5A, 1A, 1.5A, 3A, 5A, 7.5A, 10A, 15A, 20AFor 10A-10KA, Use external current transformer, which secondary current is 5A.Notes: These meters measure r.m.s values and are scaled in r. m. s values.Heat resistance: Case of non-combustible plastic material according to UL-94 V0.Changeable scale: All scales with printing the technique. The dial plate with different scale,which is at the same internal value, can be changeable, But the accuracy is unchangeable.Fastening: By means of nuts, absolutely safe, fast, robust, side-by-side.Mounting depth: Max.43mm.

Model: PE-L96A, PE-L72AAccuracy: Class 1.5Specification: 3V, 5V, 7.5V, 10V, 15V, 20V, 30V, 50V, 100V, 150V, 200V, 250V, 300V,400V, 450V, Rated voltage over 450V use external resistance(rated current 5mA).Heat resistance: Case of non-combustible plastic material according to UL-94 V0.Fastening: By means of must, absolutely safe, fast, robust, side-by-side.Mounting depth: Max43mm.

MOVING COIL INSTRUMENTS WITH RECTIFIER(240 DEG) AC AMMETERS

MOVING COIL WITH RECTIFIER INSTRUMENTS(240DEG) AC VOLTMETERS

PANEL METER

PE-96

PE-96

PE-96

• A-08

Model: PE-W96, PE-W72Accuracy: Class 1.5Specification:Voltage: 50V 100V 380V 240V 415V 400V 380V 220/380V 240/415VCurrent: 1A, 5AThe voltage circuits of the meter connected with voltage transformers. Which secondary voltage is 100V, if the secondary voltage is lower than 450V, it also can be connected directly. The current circuits connected with current transformers, which se condary current is 5A. Wattmeters and varmeters with converter for three-phase three wires or four wire and single phase.Heat resistance: Case of non-combustible plastic material according to UL-94 V0.Fastening: By means of must, absolutely safe, fast, robust, side-by-sideMounting depth: Max 43mmExternal converter with size.

Accuracy:Class 1.0Model: PE-F96,PE-F72Specification:Voltage: 50V 100V 220V 380V 440VFrequency: 45~55Hz, 45~65Hz, 45~53Hz, 57~63Hz, 44~56Hz,54~66Hz, 450~550Hz, 450~650Hz, 550~650HzHeat resistance: Case of non-combustible plastic material according to UL-94 V0.Fastening: By means of nuts, absolutely safe, robust, sibe-by-side.Mounting depth: Max. 43mm.

Model: PE-PF96, PE-PF72AAccuracy: Class 2.5Voltage: 100V 220V 380V 415V 440 current: 5ASpecification: 0.5cap-1-0.5ind, 0.3cap-1-0.1ind, 0.4cap-1-0.4ind, 0.7cap-1-0.2indHeat resistance: Case of non-combustible plastic material according to UL-94 V0.Fastening: By means of must, absolutely safe, fast, robust, side-by-side.Mounting depth: Max 43mm.

MOVING COIL INSTRUMENTS FREQUENCY METERS [240 DEG]

MOVING COIL INSTRUMENTS POWER FACTOR METERS [240 DEG]

MOVING COIL INSTRUMENTS(240DEG) DC AMMETERS [240 DEG]

SIZE OF RECTANGULAR TYPE METER

Model

PE-96

PE-72

PE-48

Unit

mm

mm

mm

A

96

72

48

B

92

68

44

C

90

66

42

D

5.5

5.5

5.5

E

65

65

65

F

43

43

43

F43E65

D5.5

ABC

PANEL METER

PE-96

PE-96

PE-96

• A-09

A

BH

M

G

CE F

D

H

Model

PE-50

PE-60

PE-670

PE-80

A

50

60

60

81

B

52

60

70

81

C

23.5

24

23

22

D

13.5

11

10

12

E

4.4

9.5

11

18.5

F

12.5

11

12

13.5

G

45

52

52

63.5

H

19

24

24

32.5

M

3

3

3

3

For Hole

46

53

53

65

Name

DC Ammeter

DC Voltmeter

AC Ammeter

AC Voltmeter

Frequency Meter

Specifications

Direct connection withExt.SHUNT

Direct connection withExt.Resistor

Direct connection withExt.CT

Direct connection withExt.CT

30-1000uA 1-1000mA 1-50A1K-10KA

40-1000mV 1-1000V1K-10KA

1-1000mA 1-50A5-1000A 1K-10KA

40-1000mA 1-1000V1K-380KV50-380V

44-55Hz 45-65Hz 55-65Hz

Remarks

DIMENSIONS(MM)

Struction: Moving Coil, Moving Iron and Rectifier.Class: 2.0,2.5

TECHNICAL DATA

OUTLINE DRAWING

PE-50

PE-60

PE-70

PE-80

PANEL METER

PE-50

PE-60

PE-70

PE-80

• A-10

ROUND TYPE SERIES PANEL METER

PE-52

PE-65

PE-62T2

PANEL METER

PE-52

PE-62T2

Name

DC Ammeter

DC Voltmeter

AC Ammeter

AC Voltmeter

Specifications

Direct connection withExt.SHUNT

Direct connection withExt.Resistor

Direct connection withExt.CT

Direct connection withExt.CT

30-1000uA 1-1000mA 1-50A1K-10KA

40-1000mV 1-1000V1K-10KA

1-1000mA 1-50A5-1000A 1K-10KA

40-1000mA 1-1000V1K-380KV

Remarks

TECHNICAL DATA:

Model

PE-52

PE-65

PE-62T2

Unit

mm

mm

mm

A

58

73.5

75

G

39

39

35

F

52

65

70

E

40.5

42

65

D

26

31

45

C

4.5

4.5

8

B

66.5

83.5

90

DIMENSIONS(MM):

A

B

F

DE

C

G

OUTLINE DRAWING

• A-11

NEW TYPE PET SERIES PANEL METER

AC AMMETRS

Model: PET-80 PET-60 PET-50 PET-680 PET-780 PET-100 PET-560 PET-670Accuracy: Class 1.5Specification: 30V 50V 75V 100V 120V150V 250V 400V 450V 500V 600VFor 450V-450KV, meters can potentialtransformer with secondary voltage 100V.Heat resistance: case of non-combustibleplastic material.

AC VOLTMETRS

Model: PET-80 PET-60 PET-50 PET-680 PET-780 PET-100 PET-560 PET-670Accuracy: Class 1.5Specification: 0.1A 0.5A 1A 3A 5A 7.5A 10A 15A20A 25A 30A 40A 50A 60A.For 10A-10KA, use external current transformer withsecondary current 5A connected directly with cur-rent from 20A to 60A, the class is 2.5 .Changeable scale: The dial plate with different scale,which is at the same division and internal value, canbe changeable.

DC VOLTMETRS

Model: PET-80 PET-60 PET-50 PET-680 PET-780 PET-100 PET-560 PET-670Accuracy: Class 1.5Specif ication: 20V 30V 50V 100V 150V 200V 250V300V 450V 500V 600V can be connected directly.Measuring ranges over 450V with external resistor(rated current 5mA).Heat resistance: case of non-combustible plasticmaterial.

DC AMMETRS

Model: PET-80 PET-60 PET-50 PET-680 PET-780 PET-100 PET-560 PET-670Accuracy: Class 1.5Specification: 100 A 1mA 3mA 5mA10mA 20mA 30mA 50mA 100mA 150mA200mA 250mA 300mA 500mA 1A 3A 5A7.5A 10A 20A 30A 40A 60AFor 10A-10KA, use external 75mV 60mV45mV shunt.The accuracy of the direct reading meterfrom 20A to 60A is class 2.5 .Changeable scale: The dial plate with differentscale, which is at the same division and internalvalue, can be changeable.

FREQUENCY METERS

Model: PET-80 PET-60 PET-50 PET-680 PET-780 PET-100 PET-560 PET-670Accuracy: Class 1.0Specification:Voltmeter: 100V 220V 380V 440VFrequency: 45-55Hz 45-65Hz 54-66Hz 350-450Hz 450-550Hz 550-650HzHeat resistance: case of non-combustibleplastic material.

POWER FACTOR METER COS

Model: PET-80 PET-60 PET-50 PET-680 PET-780 PET-100 PET-560 PET-670Accuracy: Class 2.5Specification: 100V 220V 380V 440V current: 5AThree phase: 100V 220V 380V 440V current: 5ASpecification: 0.5cap-1-0.5ind 0.3cap-1-0.7ind 0.4cap-1-0.4ind 0.7cap-1-0.2indFrequency: 50Hz or 60HzHeat resistance: case of non-combustible plasticmaterial.With external converter, which size is48mm 48mm

PET-60 PET-60

METERS & CURRENT TRANSFORMERS

PET-60

PET-60 PET-60 PET-60

PANEL METER

• A-12

6145.5

26M3

B114(81)A1

A2

L

B2

Dm

ax

NEW TYPE PET SERIES PANEL METER

OUTLINE DRAWING OF SFT SERIES PANEL METER

SIZE OF SQUARE OR RECTANGULAR WITH ROUND PANEL CUT-OUT METER

Model

PET-120

PET-80

PET-780

PET-670

PET-560

PET-60

PET-50

Unit

mm

mm

mm

mm

mm

mm

mm

A1

120

80

80

70

60

60

50

A2

100

80

70

60

50

60

50

B1

84

64

54

48

34

36

34

B2

84

64

54

48

34

36

34

L

31.2

39.2

27.2

27.2

23.2

30.2

23.2

D1

47.5

47.5

47.5

47.5

47.5

47.5

44

The items of B1 and B2 for the distance of the mounting screwsThe item D1 for the size of panel cut-out of switchboard

MOVING COIL INSTRUMENT POWER METERS WATTMETER

Model: PET-W80 PET-60 PET-670 AmmetrsAccuracy: Class 1.5Specification:Voltage: Single phase:100V 220V 380VThree phase three wire: 100V 220V 380V 415VThree phase three wire: 100V 220V(380)V240( 415)VAbove-mentioned can be connected directly. The following should be connected with voltagetransformers: 380/100V 500/100V 3K/100V 6K/100 10K/100V 15K/100V 35K/100Current: 1A, 5AThe voltage circuits of the meter connected with voltage transformers. Which secondary voltage is100V. The current circuits connected with current transformers, which secondary current is 5A or 1A.Wattmeters and Varmeters with converter for three-phase three wires or four wire and single phase,which can be used for the balance and unbalance burden circuit.Heat resistance: Case of non-combustible plastic material.Fastening: By means of nuts, absolutely safe, fast, robust, side-by-sideExternal converter with size: 72mm 87.2mm 65mm

PET-60

PET-60

PANEL METER

• A-13

DIGITAL PANEL METER

D

PE-96

PE-96

PE-96

PE-96

Function: Measure AC currentModel: PE-D96A-AC, PE-D72A-AC, PE-D48A-ACFeature:1.Display: 3 1/ 2 digital.LED display(red or green)2.Accuracy: 0.5% 1 digit3.Auxiliary power: AC 110V 10% 50/60Hz AC 220V 10% 50/60Hz4.Input signal: AC current5.Measuring range: 0-20A AC, For the current over 20A can use the AC current transformer.6.Consumption:<3.2VA7.Max Signal Consumption:<0.3VA8.Operating Environment: temperature-10 ~+50 humidity: 85%9.Storage Environment: temperature-30 ~+60 humidity: 70%10.Heat resistance: case of non-combustible plastic material11.Voltage Testing: over 2000V12.Fastening: By means of nuts, absolutely safe, fast, robust, side-by-side.

DIGITAL AC AMMETER

Function:Measure AC VoltageModel: PE-D96V-AC, PE-D72V-AC, PE-D48V-ACFeature:1.Display: 3 1/ 2 digital. LED display(red or green)2.Accuracy: 0.5% 1 digit3.Auxiliary power: AC 110V 10% 50/60Hz AC 220V 10% 50/60Hz4.Input signal: AC Voltage5.Measuring range:0-600V AC, For the Voltage over 600V can use the potential transformer.6.Consumption: <3.2VA7.Max Signal Consumption:<0.3VA8.Operating Environment: temperature -10 ~+50 humidity: 85%9.Storage Environment: temperature -30 ~+60 humidity: 70%10.Heat resistance: case of non-combustible plastic material11.Voltage Testing: over 2000V12.Fastening: By means of nuts, absolutely safe, fast, robust, side-by-side.

DIGITAL AC VOLTMETER

Model: PE-D96A-DC, PE-D72A-DC, PE-D48A-DCFeature:1.Display: 3 1/ 2 digital. LED display(red or green)2.Accuracy:0.5% 1 digit3.Auxiliary power: AC 110V 10% 50/60Hz AC 220V 10% 50/60Hz4.Input signal: DC current5.Measuring range:0-20A DC, For the current over 20V can use the external shunt.6.Consumption: <3.2VA7.Max Signal Consumption:<0.3VA8.Operating Environment: temperature-10 ~+50 humidity: 85%9.Storage Environment: temperature-30 ~+60 humidity: 70%10.Heat resistance: case of non-combustible plastic material11.Voltage Testing: over 2000V12.Fastening: By means of nuts, absolutely safe, fast, robust, side-by-side.

DIGITAL DC AMMETER

Model: PE-D96V-DC, PE-D72V-DC, PE-D48V-DCFeature:1.Display: 3 1/ 2 digital. LED display(red or green)2.Accuracy:0.5% 1 digit3.Auxiliary power: AC 110V 10% 50/60Hz AC 220V 10% 50/60Hz4.Input signal: AC Voltage5.Measuring range:0-600V DC or according to your own requirement.6.Consumption: <3.2VA7.Max Signal Consumption:<0.3VA8.Operating Environment: temperature-10 ~+50 humidity: 85%9.Storage Environment: temperature-30 ~+60 humidity: 70%10.Heat resistance: case of non-combustible plastic material11.Voltage Testing: over 2000V12.Fastening: By means of nuts, absolutely safe, fast, robust, side-by-side.

DIGITAL DC VOLTMETER

• A-14

Unit

mm

mm

mm

mm

mm

mm

A

96

3.74

72

2.83

48

1.89

Model

PE-96

PE-72

PE-48

B

92

3.62

58

2.68

44

1.73

C

75

2.95

75

2.95

110

4.33

D

10

0.39

9

0.35

8

0.31

The ltem B for the size of panel cut-out of swithboard

SIZE OF RECTANGULAR TYPE METER

DIGITAL PANEL METER

PE-96

PE-96

PE-96

Model: PE-D96F, PE-D72FFeature:1.Display:4 digital.LED display(red or green)2.Accuracy:0.2% 1 digit3.Auxiliary power: AC 110V 10% 50/60Hz AC 220V 10% 50/60Hz4.Input signal: AC Voltage, rated signal value: 0-600V(admissible input Voltage error 80%,+100%)5.Measuring range: 0-1M Hz6.Consumption:<3.2VA7.Max Signal Consumption:<0.3VA8.Operating Environment: temperature -10 ~+50 humidity: 85%9.Storage Environment: temperature -30 ~+60 humidity: 70%10.Heat resistance: case of non-combustible plastic material11.Voltage Testing: over 2000V12.Fastening: By means of nuts, absolutely safe, fast, robust, side-by-side.

DIGITAL FREQUENCY METER

Single Phase Model: PE-D96PF1, PE-D72PF1Three Phase Model: PE-D96PF3, PE-D72PF3Feature:1.Display:4 digital. LED display(red or green)2.Accuracy:0.5% 3 digit3.Auxiliary power: AC 110V 10% 50/60Hz AC 220V 10% 50/60Hz4.Input signal: Voltage 100V 200V 380V or according to the requirement current:0-1A or0-5A5.Measuring range: 0-1.00(C or L)6.Consumption:<3.2VA7.Max Signal Consumption:<0.3VA8.Operating Environment: temperature -10 ~+50 humidity: 85%9.Storage Environment: temperature -30 ~+60 humidity: 70%10.Heat resistance: case of non-combustible plastic material11.Voltage Testing: over 2000V12.Fastening: By means of nuts, absolutely safe, fast, robust, side-by-side.

DIGITAL POWER FACTOR METER COS

Model: PE-D96W(Var), PE-D72W(Var)Function:measure the single phase Wattmeter, single phase Varmeter, 3P3Wwattmeter, 3P3W Varmeter, 3P4W Wattmeter or 3P4W Varmeter.Feature:1.Display:4 1/ 2 digital. LED display(red or green)2.Accuracy:1.0% 3 digit3.Auxiliary power: AC 110V 10% 50/60Hz AC 220V 10% 50/60Hz4.Input signal: Voltage 100V 200V 380V or according to the requirement current:0-5A5.Measuring range: all ranges6.Consumption:<3.2VA7.Max Signal Consumption:<0.3VA8.Operating Environment: temperature-10 ~+50 humidity: 85%9.Storage Environment: temperature-30 ~+60 humidity: 70%10.Heat resistance: case of non-combustible plastic material11.Voltage Testing: over 2000V12.Fastening: By means of nuts, absolutely safe, fast, robust, side-by-side.

DIGITAL POWER METER

OUTLINE DAWING:

C AD B

PE-96AC AMMETER

KA~

• A-15

• A-16

DIGITAL PANEL METER

PE-48

PE-48

PE-48

PE-48

Model: PE-D3A ACSize:96 48Feature:1.Display: 3 1/ 2 digital. LED display(red or green)2.Accuracy:0.5% 1 DIFIT3.Auxiliary power: AC 110V 10% 50/60Hz AC 220V 10% 50/60Hz4.Input signal: AC current5.Measuring range: 0-10A AC, For the current over 10A can use the AC current transformer.6.Consumption:<1.8VA7.Max Signal Consumption:<0.3VA8.Operating Environment: temperature -10 ~+50 humidity: 85%9.Storage Environment: temperature -30 ~+60 humidity: 70%10.Heat resistance: case of non-combustible plastic material according to UL94-V0.11.Voltage Testing: over 2000V

DIGITAL AC AMMETER

Model:PE-D3V ACSize:96 48Feature:1.Display: 3 1/ 2 digital. LED display(red or green)2.Accuracy:0.5% 1 DIFIT3.Auxiliary power: AC 110V 10% 50/60Hz AC 220V 10% 50/60Hz4.Input signal: AC Voltage5.Measuring range: 0-600A AC, For the Voltage over 600A can use the AC potential transformer.6.Consumption:<1.8VA7.Max Signal Consumption:<0.3VA8.Operating Environment: temperature -10 ~+50 humidity: 85%9.Storage Environment: temperature -30 ~+60 humidity: 70%10.Heat resistance: case of non-combustible plastic material according to UL94-V0.11.Voltage Testing: over 2000V

DIGITAL AC AMMETER

Model:PE-D3A DCSize:96 48Feature:1.Display: 3 1/ 2 digital. LED display(red or green)2.Accuracy:0.5% 1 DIFIT3.Auxiliary power: AC 110V 10% 50/60Hz AC 220V 10% 50/60Hz4.Input signal: DC current5.Measuring range: 0-20A DC6.Consumption:<1.8VA7.Max Signal Consumption:<0.3VA8.Operating Environment: temperature -10 ~+50 humidity: 85%9.Storage Environment: temperature -30 ~+60 humidity: 70%10.Heat resistance: case of non-combustible plastic material according to UL94-V0.11.Voltage Testing: over 2000V

DIGITAL DC AMMETER

Model:PE-D3V DCSize:96 48Feature:1.Display: 3 1/ 2 digital. LED display(red or green)2.Accuracy:0.5% 1 DIFIT3.Auxiliary power: AC 110V 10% 50/60Hz AC 220V 10% 50/60Hz4.Input signal: AC voltage5.Measuring range: 0-600V DC6.Consumption:<1.8VA7.Max Signal Consumption:<0.3VA8.Operating Environment: temperature -10 ~+50 humidity: 85%9.Storage Environment: temperature -30 ~+60 humidity: 70%10.Heat resistance: case of non-combustible plastic material according to UL94-V0.11.Voltage Testing: over 2000V

DIGITAL DC VOLTMETER

• A-17

Model: PE-D3W,PE-D3VarSize:96 48Funtion:measure the single phase Wattmeter, Varmeter, 3P3W wattmeter, 3P3WVarmeter, 3P4W Wattmeter or 3P4W Varmeter.Feature:1.Display: 3 1/ 2 digital. LED display(red or green)2.Accuracy:1.0% 1 DIFIT3.Auxiliary power: AC 110V 10% 50/60Hz AC 220V 10% 50/60Hz4.Input signal: Voltage 100V, 220V, 380V or the requirement current:0-5A5.Measuring range: all ranges6.Consumption:<1.8VA7.Max Signal Consumption:<0.3VA8.Operating Environment: temperature-10 ~+50 humidity: 85%9.Storage Environment: temperature-30 ~+60 humidity: 70%10.Heat resistance: case of non-combustible plastic material according to UL94-V0.11.Voltage Testing: over 2000V

Model: PE-D3FSize:96 48Feature:1.Display: 4 digital. LED display(red or green)2.Accuracy:0.2% 1 DIFIT3.Auxiliary power: AC 110V 10% 50/60Hz AC 220V 10% 50/60Hz4.Input signal: AC Voltage, rated signal value:0-600V(admissible input Voltage error 80%, +100%)5.Measuring range: 0-1MHz6.Consumption:<1.8VA7.Max Signal Consumption:<0.3VA8.Operating Environment: temperature-10 ~+50 humidity: 85%9.Storage Environment: temperature-30 ~+60 humidity: 70%10.Heat resistance: case of non-combustible plastic material according to UL94-V0.11.Voltage Testing: over 2000V

Model: Single phase: PE-D3PF1 Three phase: PE-D3PF3Size:96 48Feature:1.Display: 4 digital. LED display(red or green)2.Accuracy:0.5% 1 DIFIT3.Auxiliary power: AC 110V 10% 50/60Hz AC 220V 10% 50/60Hz4.Input signal: Voltage 100V, 220V, 380V, or according to the requirment current:0-5A5.Measuring range: all ranges6.Consumption:<1.8VA7.Max Signal Consumption:<0.3VA8.Operating Environment: temperature-10 ~+50 humidity: 85%9.Storage Environment: temperature-30 ~+60 humidity: 70%10.Heat resistance: case of non-combustible plastic material according to UL94-V0.11.Voltage Testing: over 2000V

DIGITAL FREQUENCY METER(Hz)

DIGITAL POWER FACTOR METER COS

DIGITAL POWER METER(KW)

Model

PE-96 48mm

mm

44 92

1.73 3.62

Number of Terminal

16

A1 A2 Panel cut-out sizeUnit

96108

A1

A2

8

29.8A~ 48

64

OUTLINE DAWING: SIZE OF RECTANGULAR TYPE METER

DIGITAL PANEL METER

PE-48

PE-48

PE-48

1.for correctly use of this instrument, please read carefully this specification before operation.2.keep properly this specification after reading.Technical date

Power supply:

Display range:

Precision:

Sampling speed:

A/D convert:

Operation temperature:

Power consumption:

AC 220V AC,DC 90-270V OR AC, DC 36-72V

MAX.DISPLAY 1999 LED 12.2mm H

0.5%fs 1 digit

About 2.5 TIMES/S

Dual scope

0~50

<3W

Weight:

Size:

Hole:

About300g

96mm(w) 48mm(h) 112mm(d)

93mm 45mm

AC 1500V 1MIN

DC 500V>100M

AC voltage range change

MAX.INPUT: AC600V

NO

7

6

5

4

600

3

199.9

2

19.99

1

First: AC600VModel: PE 35-AVModel: PE-96-AC

ON

1 2 3 4 5 6 7

AC current range change

MAX.INPUT:AC5A

NO

7

6

5

4

1999

199.9

19.99

1.999

3

1500

150.0

15.00

1.500

2

1000

100.0

10.00

1.000

1

500

50.0

5.00

.500

First: AC 1999/5VModel: PE 35-AAModel: PE-96-AA

ON

1 2 3 4 5 6 7

DC voltage range change

MAX.INPUT: AC600V

NO

7

6

5

4

600

3

199.9

2

19.99

1

1.999

First: DC600VModel: PE 35-DVModel: PE-96-DV

ON

1 2 3 4 5 6 7

DC current range change

MAX.INPUT:DC75mV

NO

7

6

5

4

1999

199.9

19.99

1.999

3

1500

150.0

15.00

1.500

2

100

100.0

10.00

1.000

1

500

50.0

5.00

.500

First: DC 199/75mvModel: PE 35-DAModel: PE-96-DA

ON

1 2 3 4 5 6 7

OPERATION RANGE

DESCRIPTION OF WIRING TERMINAL

(1).For best performance, the meter should be pre-heated 15minutes before operation if it is not use for a long time.(2).The meter should be used under condition of:Ambient temperature: 0-50 , Relative humidity: 85%(3). The calibration interval should be one year; the precision ofcalibrator should be superior to 0.1 Grade.(4). The meter should prevent from shocking and im pulsing, and should not use under condition of heavy dust or high concentration chemical drug or gas. Plea se apply power supply filter or other anti-interference circuit when use the meter in environment of high mag-netic field, high frequency or high voltage spark.(5). The calibrating rheostat is use for calibrating the meter, non-professional should not calibrate or disassembly the meter, as wellas no calibrator available.

18 10

12379

Input

H L

NC.

AC 220Vpower supply

AC 110V

1 2 3 4

5 6 7 8

H LINPUT

AC 220V

Power supply

AC 110V

PE35 wiring terminalSIZE:96 48 112mmHOLE:92 44mm

PE-96 wiring terminalSIZE:96 96 65mmHOLE:90 90mm

MAX.INPUT

Insulationstrength:Insulation

impedance:

VOLTAGE METER 600VCURRENT 5A AC>5A CT/5A DC/75mV

DIGITAL PANEL METER

TECHNICAL DATA

NOTE

PE-96A-S

DIGITAL PANEL METER

PE-96

• A-18

DIGITAL PANEL METER

For correctly of this instrument, please read carefully this specification before operation.Check the ratio CT value if match with ratio meter.Keep properly this specification after reading.1.Digit panel-type meter is a digital measurement instrument, which applying dual-integral method, consists of LSI and high-reliable components, high-accuracy A/D conver circuit and high-brightness LED display, with feature such as advanced design,reasonable distribution of components, nice appearance and easy to install. It is mainly use as displaying meter for every kindof instuments.2.Corretly connect the meter to power supply(AC220V) before using, clients also can select the meter with power supply otherthan AC220V(when supply by DC power, polarity must be correctly connected, otherwise, the meter will be destroyed).3.AC or DC imput voltage within measuring range(0-600V) could be measure and display directly. When the input voltage is morethan 600V, the meter must match with constant mutual-inductor.4.AC or DC input current within measuring range(0-10A) can be measure and display directly. When the AC input current ismore than 10A, the meter must match with constant mutual-inductor, when the DC input current is more than 10A, themeter must match with constant current-divide mutual-inductor, the display value will be error if the ratio of current-divider is notmatch with the meter.5.Commercial frequency meter sample the AC voltage signal, the merer can display directly the frequency value when inputvoltage signal is between 30V-600V, and the frequency measuring range is from 10.0Hz to 2000Hz.6.Single-phase or three-phase wattmeter and power-factor meter, please connect correctly according to the wiring diagram onthe meter, check carefully the high(H) and low(L) label beside the voltage or current input terminal. The display value will be errorif connect wrongly. The input voltage can be selectable with 100V, 220V or 380V, the input current should be between 0 to 5A, ifthe input current is more than 5A, the meter must match with constant current mutual-inductor, otherwise the display valueshould be error.7.As for input sensor signal is between 4 to 20 mA or 0 to 10V, the meter can be made to order by clients for measuing and display temperature, rotate speed or pressure, the specification is cover by other copy.8.Note:(1).For best performance, the meter should be pre-heated 15 minutes before operation if it is not use for a long time.(2).The meter should be used under condititon of:Ambient temperature: 0-50 , Relative humidity: 85%(3).The calibration interval should be one year; the precision of calibrator should be superior to 0.1 Grade.(4).The meter should prevent from shocking and impulsing, and should not use under conditon of heavy dust or high concentrationchemical drug or gas. Please apply power supply filter or other anti-interference circuit when use the meter in environment ofhigh magnetic field, high frequency or high voltage spark.(5). The calibrating rheostat is use for calibrating the meter, non-professional should not calibrate or disassemblythe meter, as well as no calibrator available.

DIGITAL PANEL METER

PE-96PE-96

• A-19

MODULAR TYPE PANEL METER

DC VOLTMETRS

Model: PE-C45VAccuracy: Class 1.5Specification:20V 30V 50V 100V 150V 200V 250V 300V 450V 600V 1000VMeasuring ranges over 450V with external re-sistor (rated current 5mA)Heat resistance: case of non-combustible plasticmaterial.Mounting type: DIN rail

FREQUENCY METERS AC VOLTMETRS

Model: PE-F45VAccuracy: Class 1.0Specification:Voltmeter: 100V 220V 380V 440VFrequency: 45-55Hz 45-65Hz 47-63Hz 57-63Hz 44-56Hz 54-66Hz 350-450Hz 450-550Hz 550-650HzHeat resistance: case of non-combustible plasticmaterial.Mounting type: DIN rail

Model: PE-F45VAccuracy: Class 1.0Specification:30V 50V 75V 120V 120V 150V 250V 400V 450V 500V 600VFor450V-450KV, meters can use potential trans-former with secondary voltage 100V.Heat resistance: case of non-combustible plasticmaterial.Mounting type: DIN rail

DC AMMETRS POWER FACTOR METER COS AC VOLTMETRS

Model: PE-T45AAccuracy: Class 1.5Specification: 100 A 500 A lmA 3mA5mA 10mA 20mA 30mA 50mA 100mA 150mA200mA 250mA 300mA 500mA 1A 3A 7.5A10A 15A 20AFor 10A-10KA, use external 75mV 60mV or45mV shunt. For the direct reading from 20A to60A meter the class is 2.5A.Heat resistance: case of non-combustible plasticmaterial.Changeable scale: The dial plate with the samescale division, which is at the same internal value,can be changeable.

Model: PE-PF45Accuracy: Class 2.5Single phase: 100V 220V 380V 440V current: 5AThree phase: 100V 220V 380V 440V current: 5ASpecification: 0.5cap-1-0.5ind 0.3cap-1-0.7ind 0.4cap-1-0.4ind 0.7-1-0.2indHeat resistance: case of non-combustible plasticmaterial.Frequency: 50Hz or 60HzMounting type: DIN rail

Model: PE-T45AAccuracy: Class 1.5 2.5Specification: 0.1A 0.5A 1A 7.5A 10A 15A 20A 30A 40A 60AFor 10-10KA, use external current transformerwith secondary current 5A. For the direct readingfrom 20A to 60A meter, the class is 2.5 .Heat resitance: case of non-combustible plasticmaterial.Changeable scale: All scales with printingtechnique. The dial plate with the same scaledivision, which is at the same division and inter-nal value, can be changeable.

PE-C45V PE-C45VPE-C45V

PE-C45VPE-C45V

PE-C45V

MODULAR TYPE PANEL METER

• A-20

45.3

30.6

8.5

K

45.3

62.7

6435

51.7

19.7

D

87.2

65

32

1 2 3 4220V

MOVING COIL INSTRUMENT POWER METERS

Wattmeter Model: PE-W45Varmeter Model: PE-VAR45Accuracy: Class 1.5Specification:Voltage: Single phase: 100A 200V 380VThree phase three wire: 100A 220V 380V 415VThree phase four wire: 100A 220V(380)V 240V( 415)VAbove-mentioned can be connected directly. The following should be connected with voltagetransformers: 380/100V 500/100V 3K/100V 6K/100V 10K/100 15K/100V 35K/100V...Current: 1A, 5AThe voltage circuits of the meter connected with voltage transformers. Which secondary voltage is100V, if the secondary voltage is lower than 450V, it also can be connected directly. The currentcircuits connected with current transformers, which secondary current is 5A or 1A. Wattmeters andVarmeters with converter for three-phase three wires or four wire and single phase, which can beused for balance and unbalance burden circuit.Heat resistance: Case of non-combustible plastic material.Frequency: 50Hz or 60HzFastening: By means of nust, absolutely safe, fast, robust, side-by-sideMounting: DIN rail: 72mm 87.2mm 65mm

MODULAR (EXPLOSION-PROOF)OUTLINE DRAWING

PE-36

PE-100

SIZE OF DIN RAIL TYPE SERIES METER

Model

PE-36

PE-45

PE-100

Unit

mm

mm

mm

D

36

45

100

Number of Terminal

4

4

10

Measurement of Din Rail

35

35

35

PE-VAR45

PE-W45

PE-Var45

PE-W45

MODULAR TYPE PANEL METER

• A-21

DIGITAL MODULAR AC & DC AMMETER AND VOLTMETERModel: PE-D365 AC PE-D365 DCFeature:1. Display: 3 1/2digits. LED display (red or green)2. Accuracy: 0.5% 2 digits3. Auxiliary power: AC 110V 10% 50/60Hz or AC 110V 10% 50/60Hz4. Input signal: AC current8.5. Measuring range: 0-10A Acm if the current morethan 1A, the meter should be used with current trans- former.0-10A DC, if the current more than 10A, the meter should be used with shunt.6. Consumption: <1.8VA7. Max Signal Consumption: <0.3VA8. Operating Environment: temperature0 ~-40 humidity: 85%9. Storage Environment: temperature-40 ~+60 humidity: 70%10. Heat resistance: case of non-combustible plastic material11. Hi-pot testing: more than 2000V

POWER FACTOR METER COSORDCRING MODEL (SINGLE PHASE): PLY-D725PF(1P)(3 PHASE): PLY-D725PF(3P)

Feature:1. Display: 4digits. LED display (with red and green options)2. Accuracy: (0.5% reading +3 digits)3. Auxiliary power: AC 110V 10% 50/60Hz or AC 110V 10% 50/60Hz4. Input Signal: 100V,220V,380V Current 0-1A or 0-5A is at users option.5. Measuring range: 0o -360o phase angle.6. Power Consumption: <3.2VA7. Maximum Voltage Consumption: <0.5VA Maximum Current Consumption: <0.5VA8. Operating Environment: 0 ~-40 Relative Humidity: 85%9. Shelf Environment: -40 ~+60 Relative Humidity: 70%10. Hi-pot Testing: AC 2000V/1min11. External Case: Made of non-flammable plastic material.12. Fixing Mode: Sliding in (PLY-D120); Din rail mode (PLY-D725)13. Imbedding Depth: 53mm (PLY-120); 65mm (PLY-D725)

DIGITAL POWER METER

Ordering Model: PLY-D725W (Var)Function: For measuring single phase withpower, single phase without power.Feature:1. Display: 4 1/2digital LED display(with red and green options)2. Accuracy: (0.5% reading +3 digits)3. Auxiliary power: AC 110V 10% 50/60Hz and AC 220V 10% 50/60Hz4. Input Signal: Voltage 100V, 220V, 380V. Current 0-1A or 0-5A is atusers option.5. Measuring Range: At users option.6. Power Consumption: <3.2VA7. Maximum Voltage Consumption: <0.5VA Maximum Current Consumption: <0.5VA8. Operating Environment: 0 ~40 . Relative Humidity: 85%9. Shelf Environment: -40 ~+60 Relative Humidity: 70%10. Hi-pot Testing: AC 2000V/1 min11. External Case: Made of non-flammable white plastic material.12. Fixing Mode: Sliding in (PLY-D120); Din rail mode (PLY-D725)13. Imbedding Depth: 53mm (PLY-120); 65mm (PLY-D725)

PLY-D725

PE-D36A

PE-D36V

MODULAR TYPE PANEL METER

• A-22

Function: For measuring the DC/AC current andvoltage.Ordering Model: PLY-D725A/V or DCFeature:1. Display: 3 1/2digital LED display (with red and green options)2. Accuracy: (0.5% reading +2 digits)3. Auxiliary Power: AC 110V 10% 50/60Hz or AC 220V 10% 50/60Hz4. Input Signal: AC/DC current and voltage.5. Measuring Range: 0-20A AC, for those above20A, match with current transformer;0-20A DC for those above 20A, match with shunt;0-600V-AC for those above 600V, match with voltage transformer.0-600V-DC6. Power Consumption: <3.2VA7. Maximum Signal Consumption: <0.5VA8. Operating Environment: 0 ~40 . Relative Humidity: 85%9. Shelf Environment: -40 ~+60 Relative Humidity: 70%10. Hi-pot Testing: AC 2000V/1 min11. External Case: Made of non-flammable plastic material.12. Fixing Mode: Flush fixing with nuts.13. Imbedding Depth: 43mm

DIGITAL AC/DC AMMETER & VOLTMETER

Ordering Model: PLY-D725FFeature:1. Display: 4digital LED display (with red and green options)2. Accuracy: (0.1% reading +1 digits)3. Auxiliary Power: AC 110V 10% 50/60Hz or AC 220V 10% 50/60Hz4. Input Signal: VC voltage, rated signal amplitude value 0-600V optional (Input voltage error allowance: -80%, +100%)5. Measuring Range: 1.000-9999Hz6. Power Consumption: <3.2VA7. Maximum Signal Consumption: <0.5VA8. Operating Environment: 0 ~40 Relative Humidity: 85%9. Shelf Environment: -40 ~+60 Relative Humidity: 70%10. Hi-pot Testing: AC 2000V/1 min11. External Case: Made of non-flammable plastic material.12. Fixing Mode: Sliding in (PLY-D120); Din rail mode(PLY-D725)13. Imbedding Depth: 53mm(PLY-120);65mm (PLY-D725)

DIGITAL FREQUENCY METER

PLY-D725

PLY-D725

ELECTRIC CABLE FITTING

• A-23