Series S Panel meter 72x36mm with function time counter and chronometer. Fully configurable. Up and down counting modes. Reading in decimal and sexagesimal formats. Controls for ‘Start’, ‘Stop’ and ‘Reset’. Special working modes with second timer for accumulative time, exceeded time, cycle counter, display hold and memory of cycle duration (maximum and minimun duration of cycle). Controls by mechanical contact and configurable for TTL, NPN, push-pull, inductive, etc. Front and rear reset. Size 72x36 mm. 4 digits. Universal AC and DC power modules. Up to 2 modules for signal retransmission and control (relay outputs, analogue outputs, ...). Panel Meters FEMA ELECTRÓNICA USER’S MANUAL (3216R02) Panel meter 72x36mm Model S40-CR Time counter Chronometer

Panel Meters Series SPanel meter 72x36mm chronometer Configurable chronometer and time counter. Selectable reading in 12 different formats, with hours, minutes, seconds and days, in

  • Upload
    others

  • View
    15

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Panel Meters Series SPanel meter 72x36mm chronometer Configurable chronometer and time counter. Selectable reading in 12 different formats, with hours, minutes, seconds and days, in

Series S

Panel meter 72x36mm with function time counter and chronometer. Fully configurable.

Up and down counting modes. Reading in decimal and sexagesimal formats.

Controls for ‘Start’, ‘Stop’ and ‘Reset’. Special working modes with second timer for

accumulative time, exceeded time, cycle counter, display hold and memory of cycle

duration (maximum and minimun duration of cycle). Controls by mechanical contact

and configurable for TTL, NPN, push-pull, inductive, etc. Front and rear reset. Size

72x36 mm. 4 digits. Universal AC and DC power modules. Up to 2 modules for signal

retransmission and control (relay outputs, analogue outputs, ...).

Panel Meters

FEM

A E

LEC

TRÓ

NIC

A

USER’S MANUAL(3216R02)

Panel meter 72x36mm

Model S40-CR Time counterChronometer

Page 2: Panel Meters Series SPanel meter 72x36mm chronometer Configurable chronometer and time counter. Selectable reading in 12 different formats, with hours, minutes, seconds and days, in

User’s Manual S40-CR

FEMA ELECTRÓNICA - Page 2

1. Meter S40-CRPanel meter 72x36mm chronometerConfigurable chronometer and time counter. Selectable reading in 12 different formats, with hours, minutes, seconds and days, in decimal or sexagesimal (clock) format. Up and down counter. Preset value configurable.

Controls

Chronometer with 3 inputs ‘A’, ‘B’ and ‘R’ to control ‘Start’, ‘Stop’ and ‘Reset’ functions. Functions activated by mechani-cal contacts, on falling edge. Also configurable for push-pull, NPN, PNP, TTL, inductive, etc, by internal pull-up/pull-down resistors, trigger levels, excitation voltage and antirrebound filters. Activation also configurable for rising edge or levels.

Alternative connection (‘con.2’)

Using alternative connection (‘con.2’) signal level on input ‘A’ controls ‘Start / Stop’ function, signal level on input ‘R’ controls ‘Reset’ function, and signal level on input ‘B’ controls activation of special function (see ‘Special functions on input ‘B’’ further in this section).

Memory

The instrument retains last reading on memory in case of power loss. Memory of maximum and minimum reading are accessible from frontal keypad.

Reset

Front and rear reset available. Front reset can be disabled. Rear reset configurable for activation on falling-edge, raising-edge, or level.

Alarms

Instrument with up to 2 alarms that control 2 relay outputs (optional). Alarms configurable with ‘normal’ mode (alarm activates when setpoint is reached) and ‘repeat’ mode (alarm activates each time the setpoint time has passed). See sec-tion ‘1.5 Alarm modes’ for more information.

Each alarm has a parameter ‘On_Alarm’ which allows to configure a stop, a reset, a jump to 0, or continue (nothing done) when alarm is reached. Using ‘On_Alarm’ configured to ‘reset’ allows to create cycles that can be counted with special function ‘B.2’.

Special functions on input ‘B’

Special functions can be assigned to input ‘B’ :

function ‘B.1’ (up / down control) - signal on input ‘B’ controls the chronometer counting direction.

function ‘B.2’ (cycles) - internal counter is activated, and its value increased by ‘+1’ each time the configured alarms get activated. To view the internal counter value, activate input ‘B’. Together with parameter ‘On_Alarm / Reset’, time cycles can created and counted.

function ‘B.3’ (accumulated) - internal chronometer is acti-vated, counting the total time that the instrument has been powered, the total time that the main chronometer has been stopped or the total time that the main chronometer has been counting (‘Start’). To view the internal chronometer value, activate input ‘B’.

function ‘B.4’ (exceeded) - internal chronometer is activated, counting the time passed since the configured alarm got active. To view the internal chronometer value, activate input ‘B’.

function ‘B.5’ (hold) - status of channel ‘B’ controls the dis-play hold, while the main chronometer continues counting on the background.

function ‘B.6’ (maximum and minimum cycle duration) - signal ‘Reset’ updates the maximum and minimum memory values, for a repetitive cycle. Application to save maximum and minimum production times of a certain process.

Flashing

Several configurations available to activate flash on display in case of stop, start or alarm activation.

First start security

Function ‘On power-up’ defines a delay time in case of power on, the default starting mode (‘Start’ or ‘Stop’) and optional reset activation.

Configurable quick access

The UP (5) keypad gives quick access to the functions selected by the user, such as alarm setpoints, preset value and memories of maximum and minimum.

Control options

Optional up to 2 relay outputs, and analog outputs with 4/20mA and 0/10Vdc.

Mechanical

Standard 72x36mm size. Universal AC and DC power op-tions. IP54 front protection, with optional IP65. Optional with green led. Connections via plug-in screw terminals and configuration via three front push-buttons. For industrial ap-plications.

Page 3: Panel Meters Series SPanel meter 72x36mm chronometer Configurable chronometer and time counter. Selectable reading in 12 different formats, with hours, minutes, seconds and days, in

User’s Manual S40-CR User’s Manual S40-CR

FEMA ELECTRÓNICA - Page 3

S40 CR H

Model Power

-H (85-265 Vac/dc)-L (11-60 Vdc and 24/48 Vac)

- - - ---

Option1

-R1 (1 relay)-AO (Analogue output)- (empty)

- ---

Others

-65 (IP65)-G (green)-NBT (no buttons)- (empty)

---

Option2

-R1 (1 relay)-AO (Analogue output)- (empty)

-

1.1 Order reference

Index

1. Meter S40-CR . . . . . . . . . . . . . . . . . . . . . 21.1 Order reference . . . . . . . . . . . . . . . . . . . 31.2 Front view. . . . . . . . . . . . . . . . . . . . . . 31.3 Rear view . . . . . . . . . . . . . . . . . . . . . . 31.4 Control led . . . . . . . . . . . . . . . . . . . . . 41.5 Alarm modes . . . . . . . . . . . . . . . . . . . . 41.6 Utility ‘Trigger Sense’ . . . . . . . . . . . . . . . . 41.7 Connections . . . . . . . . . . . . . . . . . . . . 41.8 Input channel configuration . . . . . . . . . . . . . 51.9 Power Connections . . . . . . . . . . . . . . . . . 51.10 Operating the menus . . . . . . . . . . . . . . . 51.11 Technical data . . . . . . . . . . . . . . . . . . . 61.11 Technical data (cont.) . . . . . . . . . . . . . . . 61.12 Mechanical dimensions (mm) . . . . . . . . . . . 61.13 Configuration menu . . . . . . . . . . . . . . . . 8

1.13.1 Menu Fn.b.1 - Control Up/Down . . . . . . . 101.13.2 Menu Fn.b.2 - Cycles . . . . . . . . . . . . 101.13.3 Menu Fn.b.3 - Accumulated . . . . . . . . . 101.13.4 Menu Fn.b.4 - Exceeded . . . . . . . . . . . 101.13.5 Menu Fn.b.5 - ‘Hold’ . . . . . . . . . . . . . 101.13.6 Menu Fn.b.5 - ‘Max / Min’ . . . . . . . . . . 10

1.14 Configuration menu descriptions . . . . . . . . 111.14.1 Function . . . . . . . . . . . . . . . . . . . . 11

1.14.2 Configuration. . . . . . . . . . . . . . . . . . 111.14.3 Input ‘B’ functions . . . . . . . . . . . . . . . 111.14.4 Menu Sensor . . . . . . . . . . . . . . . . . 121.14.5 Menu Alarms . . . . . . . . . . . . . . . . . 121.14.6 Menu Tools . . . . . . . . . . . . . . . . . . 131.14.7 Menu OptX - Options. . . . . . . . . . . . . 13

1.15 Default factory configuration. . . . . . . . . . . 131.16 Accessing the instrument . . . . . . . . . . . . 141.17 Messages and errors . . . . . . . . . . . . . . 141.18 Warranty . . . . . . . . . . . . . . . . . . . . . 151.19 Installation precautions . . . . . . . . . . . . . 151.20 CE declaration of conformity . . . . . . . . . . 15

2. Output and control modules . . . . . . . . . . . . . 162.1 Module R1 . . . . . . . . . . . . . . . . . . . . 162.2 Module AO . . . . . . . . . . . . . . . . . . . . 162.3 Modules R2, R4. . . . . . . . . . . . . . . . . . 17

3. More options and accessories . . . . . . . . . . . . 183.1 Option G . . . . . . . . . . . . . . . . . . . . . 183.2 Option IP65 . . . . . . . . . . . . . . . . . . . . 18

1.2 Front viewAlarms

Logo

Button ‘UP’ Button ‘SQ’Button ‘LE’Access to ‘Configuration menu’ (press 1 sec.)

Units

Front reset Quick access

1.3 Rear view

PowerControls

Option1 Option2

0 X A B R 8 9 0

Control led

Page 4: Panel Meters Series SPanel meter 72x36mm chronometer Configurable chronometer and time counter. Selectable reading in 12 different formats, with hours, minutes, seconds and days, in

User’s Manual S40-CR

FEMA ELECTRÓNICA - Page 4

1.4 Control led

The ‘Control led’ (see section 1.2) flashes when the chronom-eter is counting (‘Start’). It remains off when the chronometer is stopped (‘Stop’). The ‘Control led’ function is to indicate when the chronometer is counting. The flashing rate is 1 second.

By default, the control led is enabled in reading formats which include minutes, hours or days, and disabled in reading formats which include seconds, tenths of second or cents of second.

The chronometer S40-CR has 2 configurable alarms (‘AL1’ and ‘AL2’). Each alarm controls a relay ‘R1’ (optional) and each alarm can be configured in three different modes :

‘oFF’ - Alarm disabled. Alarm performs no function.

‘Normal’ - Normal mode. Alarm activates when reading reaches the setpoint value. Configuration includes definition of setpoint value, alarm of maximum or minimum, configu-ration of delay for relay deactivation and a second optional setpoint to create windowed alarms. When alarm setpoint is reached, an action can be defined (‘stop’, ‘preset’, ‘reset to 0’ or ‘continue’) and a flashing control can be applied (see section ‘1.14.5 Alarms menu’ for more information).

‘Repeat’ - Repeat mode. Alarm activates each time the chronometer reaches a multiple of the setpoint. For example, with setpoint configured at 15:00 minutes, alarm will activate at 15.00, 30.00, 45.00, etc. Alarm remains active during the time configured on parameter ‘dEL.1’. After this time, alarm is deactivated.

In down counting mode, with preset at 60:00 and setpoint at 20:00, alarm will activate at 40:00, 20:00 and 0:00. To stop chronometer at 0.00 configure Alarm2 in ‘Normal’ mode, con-figured as minimum alarm, with setpoint at 0.00 and function ‘On_Alarm / Stop’.

In ‘Repeat’ mode only the following parameters apply : ‘SEt’ for setpoint value and ‘dEL.1’ for delay deactivation. Other parameters such as ‘Type’ (alarm of maximum or minimum), ‘Set2’ (second setpoint), ‘on.Al’ (function to apply on alarm ac-tivation) and ‘FL.AL’ (flash on alarm activation) do not affect.

Note - repeat mode is not functional in formats which visualize tenths of second or cents of second.

1.5 Alarm modes

1.6 Utility ‘Trigger Sense’

1.7 ConnectionsDefault connections (‘Con.1’)

The chronometer has 3 input channels (terminals ‘A’, ‘B’ and ‘R’) to control ‘Start’, ‘Stop’ and ‘Reset’ functions. By default, activation is on falling-edge, connecting the input terminal to 0V. For other configurations (NPN, PNP, ...) see section 1.8.

Alternative connections (‘Con.2’)

The alternative connections ‘Con.2’, is automatically selected when a special function is enabled (see section ‘1.14.3 Chan-nel ‘B’ functions’).

Working with the alternative connections ‘Con.2’, function ‘Start / Stop’ is controlled with input ‘A’. Input ‘A’ in low level (closed contact) activates ‘Start’ function. Input ‘B’ in high level (open contact) activates ‘Stop’ function. For other con-figurations (NPN, PNP, ...) see section 1.8.

0V

A - Start / Stop

Vexc

B - Special function

R - Reset

5V2K4

2K4

2K4

RBA

0 X A B R

0V

A - Start

Vexc

B - Stop

R - Reset

5V2K4

2K4

2K4

RBA

0 X A B R

Visualizes the input state of channels ‘A’, ‘B’ and ‘R’, while adjusting the trigger level of the instrument (“<” / “SnSr” / “trIG”). Value is between 0 and 31 levels, where each level represents 0.12Vdc (a trigger value of 15 is fixed to 1.8Vdc).

Channel B to ‘0’

Channel B to ‘1’

Channel A Channel B Channel R

Trigger level

Page 5: Panel Meters Series SPanel meter 72x36mm chronometer Configurable chronometer and time counter. Selectable reading in 12 different formats, with hours, minutes, seconds and days, in

User’s Manual S40-CR User’s Manual S40-CR

FEMA ELECTRÓNICA - Page 5

1.9 Power ConnectionsEarth connection - Although a terminal is offered for earth connection, the connec-tion is optional. The instrument does not need this connection for correct function-ing nor for compliance with the security regulations.

Fuse - To comply with security regulation 61010-1, add to the power line a protection fuse acting as disconnection element, eas-ily accessible to the operator and identified as a protection device.

~

~ +

-

8 9 0

Power “H” fuse 250mA time-lag

Power “L” fuse 400mA time-lag

Inputs ‘A’, ‘B’ and ‘R’ are controlled (by default) with direct connections to 0V (free potential contact) and are activated by falling-edge (in default connection mode ‘Con.1’). Instrument has internal pull-up resistors enabled on each input and a 0V terminal to close the contact. For other configurations see the ‘Sensor’ section of the ‘Configuration Menu’ (‘<’ / SnSr).

Configuration for inputs ‘A’ and ‘B’

Inputs ‘A’ and ‘B’ share the following configuration parameters : pull-up / pull-down resistors, trigger levels and activation by rising or falling edge (connection type ‘Con.1) or activation by high or low level (connection type ‘Con.2’).

Configuration for input ‘R’ (rear reset)

Channel ‘R’ controls the ‘Reset’ function and its configuration is independent from inputs ‘A’ and ‘B’. It has its own pull-up / pull-down resistor, trigger level fixed to 2.5V and activation by high or low signal (edge or level control is configurable at menu entry ‘<’ / Tools / r.rSt).

Common controls

Excitation voltage (available from 5V to 18V on terminal ‘X’) provides excitation for sensors up to 70mA. Antirrebound filters apply to inputs ‘A’, ‘B’ and ‘R’.

All these parameters are available inside the ‘Configuration menu’ and allow to adapt the instrument to a wide variety of controls, such as NPN, PNP, push-pull, namur, mechanical contact, TTL, CMOS, pick-up, inductive, ...

1.8 Input channel configurationThe instrument has two menus accessible to the user :

‘Configuration menu’ (key SQ) (<) ‘Quick access menu’ (key UP) (5)

The ‘configuration menu’ allows to change the configuration of the instrument. Press keypad (<) during 1 second to enter this menu. Access to the ‘configuration menu’ can be protected enabling the ‘PASSWORD’ function. During operation with the ‘configuration menu’ the alarms are kept ‘on-hold’.

While operating inside the ‘configuration menu’ the chronom-eter does not count. When leaving the ‘configuration menu’ the instrument restarts and applies the configuration indicated at menu entry ‘On Power Up’ (see section 1.14.2).On restart of the instrument, also the optional modules are restarted (relays, analogue outputs, ...).

The ‘quick access menu’ is a configurable menu, accessible through key UP (5), where the user can configure access to the following information : memory values for maximum, minimum and cycles, setpoint values for alarms 1, 2 and 3 and preset value. The list of configurable parameters is accessible at “tooL” / “k.uP”. Alarm setpoints and preset value can be modified when enabled in the ‘quick access menu’. If only one parameter is configured to be accessed through the ‘quick ac-cess menu’, access to this parameter value is direct with only one touch on the UP (5). The ‘PASSWORD’ function does not block access to the ‘quick access menu’. While working inside the ‘quick access menu’ the instrument keeps working as normal in the background. There is no reset when leaving the ‘quick access menu’.

Rollback - After 30 seconds without interaction from the operator, the instrument leaves the active menu and returns normal working mode. All changes are discarded.

Key SQ (<) - Selects the menu entry currently displayed. When entering a numeric value (for example a setpoint value) validates the value on display.

Key UP (5) - Moves vertically on the menu entries. When entering a numeric value (for example a setpoint value) modi-fies the current digit by increasing its value up from 0 to 1, 2, 3, 4, 5, 6, 7, 8, 9.

Key LE (3) - Leaves the current menu. Pressing LE several times will leave all menus. When leaving all menus in the configuration menu, changes will be saved . When entering a numeric value (for example a setpoint value) it moves from one digit to the next. Each digit value can then be modified with the UP button.

1.10 Operating the menus

Page 6: Panel Meters Series SPanel meter 72x36mm chronometer Configurable chronometer and time counter. Selectable reading in 12 different formats, with hours, minutes, seconds and days, in

User’s Manual S40-CR

FEMA ELECTRÓNICA - Page 6

Digits 4Type 7 segmentsColor red or greenHeight 14 mm

Reading formats*Nomenclature (d=days, h=hours, m=minutes, s=seconds, c=cents of sec.)

Sexagesimal reading formatsdd.hh hh.mm mm.ss

Decimal reading formatsssss mmmm hhhhsss.s mmm.m hhh.hss.ss mm.mm hh.hh

Maximum reading 99.59 / 99.23 / 9999Minimum reading -19.59 / -19.23 / -1999

AccuracyOf the quartz oscillator ±0.01%Thermal drift 20ppm/ºC

Controls Start, Stop, ResetDefault signal Free potential contactConfigurable for ... push-pull, NPN, PNP, Pick-up,

TTL, inductive, mechanical, ...Maximum Vdc at input ±30VdcVexc configurable 5V, 9V, 15V, 18V (max 70mA)

RefreshDisplay refresh 12 / second

Power Power “H” 85 to 265 Vac/dcPower “L” 11 to 60 Vdc and 24/48VacConsumption <4WIsolation 3500Veff for power “H”(tested 60 seconds) 2000Veff for power “L”

Configuration 3 frontal push buttons

Functions availablePreset yes, configurableCount direction up / downMemory of counter yes, recovers data on power lossReset configurable yes, front and/or rear reset and/or

assigned to setpointFunctions ‘On_Alarm’ yes, configurableZeros to the left yes, configurablePassword yes, configurableBrightness control yes, 5 levels

Optional boards maximum 2 (see section 2)

MechanicalMounting panelConnections plug-in screw terminalsWeight <150 gramsHousing materials ABS, polycarbonateFront size 72x36mmPanel cut-out 69x32.5mmDeep from panel 98mm (includes terminal)

Protection IP54 standard IP65 optional (Front filter sealed.

Opening the front filter breaks the seal)

Temperature Operation 0 to 50ºCTemperature Storage –20 to +70ºCWarm-up 15 minutes

1.11 Technical data 1.11 Technical data (cont.)

32,5

69

Panel cut-out

72

36

18 880

1.12 Mechanical dimensions (mm)

Page 7: Panel Meters Series SPanel meter 72x36mm chronometer Configurable chronometer and time counter. Selectable reading in 12 different formats, with hours, minutes, seconds and days, in

User’s Manual S40-CR User’s Manual S40-CR

FEMA ELECTRÓNICA - Page 7

T H I S P

A GE B

L A N K

Page 8: Panel Meters Series SPanel meter 72x36mm chronometer Configurable chronometer and time counter. Selectable reading in 12 different formats, with hours, minutes, seconds and days, in

User’s Manual S40-CR

FEMA ELECTRÓNICA - Page 8

Press ‘SQ’ button (<) during 1 second to enter ‘Configuration Menu’Explanation on each menu entry starts at section 1.14

Function

Up counter

Down counterCounting direction

View formats

Preset

Preset value-1999 a 9999

On Power-Up Delay

Reset

Seconds

Front resetConfiguration

1.13 Configuration menu

Trigger

Trigger level from 0 to 31. Each level represents 0.12V.Vertical leds to the left represent the state of channels ‘A’, ‘B’ and ‘R’. See section 1.6 for ‘Trigger Sense’ utility.

Sensor

Input ‘B’ func-tion selection

Function as-signed to input ‘B’. It activates connection type ‘Con.2’ (see section 1.5)

input ‘B’ function configuration

Menu varies depending on the ‘B’ function selected. See section 1.13.1 to see all menus. This entry shows “Fn.b.n” if ‘function b’ is not selected.

On rising edge

On falling edgeActivation for

reset

On rising edge

On falling edgeActivation for inputs ‘A’ and ‘B’

Flash Flash on Stop

Flash on Start

Pull Down

No pulls

Pull UpPulls for reset

Pull Down

No pulls

Pull UpPulls for inputs

‘A’ and ‘B’

State

0 a 9999

0.0 a 999.9

0.00 a 99.99

0.0 a 999.9

0.00 a 99.99

0.00 a 99.99

0.0 a 999.9

0 a 9999

0.00 a 99.59

0.00 a 99.59

0 a 9999

0.00 a 99.23

Page 9: Panel Meters Series SPanel meter 72x36mm chronometer Configurable chronometer and time counter. Selectable reading in 12 different formats, with hours, minutes, seconds and days, in

User’s Manual S40-CR User’s Manual S40-CR

FEMA ELECTRÓNICA - Page 9

1.13 Configuration menu (cont.)

Key UP Setpoint1Tools

Opción1

Menu for optional module at ‘Opt1’

Opción2

Menu for optional module at ‘Opt2’

Left Zeros

With left zeros

Without left zeros

Password Password4 digits

Version

Firmware version

Factoryconfiguration Apply

Minimum

Brightness

Maximum

Setpoint2

Menu for Alarm2

Alarm1

Alarmas

Alarm mode

Deactivated

Normal

Antirrebound

Excitationvoltage

Antirrebound filter(0 a 1000 mSec.)

Excitation voltage5, 9 ,15 ,18Vdc

Setpoint2 Second setpoint

Delay1

Delay on relaydeactivation(in seconds)

Setpoint

Setpoint

Alarm type

Al. as maximum

Al. as minimum

On alarm

Continue

To zero

To preset

Stop

Alarm Flash

See Max.

See Min

Repeat

Rear reset

By edge

By level

Cycles

Preset

Page 10: Panel Meters Series SPanel meter 72x36mm chronometer Configurable chronometer and time counter. Selectable reading in 12 different formats, with hours, minutes, seconds and days, in

User’s Manual S40-CR

FEMA ELECTRÓNICA - Page 10

1.13.1 Menu Fn.b.1 - Control Up/Down

Function B.1Control up/down

This function does not have configurable parameters

1.13.2 Menu Fn.b.2 - Cycles

Function B.2Cycles

on AL1

on AL2

on Reset

1.13.3 Menu Fn.b.3 - Accumulated

Función B.3Acumulado

Format

Count

1.13.5 Menu Fn.b.5 - ‘Hold’

Function B.5Hold

This function does not have configurable parameters

1.13.4 Menu Fn.b.4 - Exceeded

Function B.4Exceeded

Format

Start

Function B.6Max / Min

This function does not have configurable parameters

1.13.6 Menu Fn.b.6 - ‘Max / Min’

Page 11: Panel Meters Series SPanel meter 72x36mm chronometer Configurable chronometer and time counter. Selectable reading in 12 different formats, with hours, minutes, seconds and days, in

User’s Manual S40-CR User’s Manual S40-CR

FEMA ELECTRÓNICA - Page 11

Reading formats (‘View’) - Select the reading format for the chronometer. Nomenclature for the reading formats indicated below is : d=days, h=hours, M=minutes, S=seconds, c=cents. (To the right, minimum value in the negative range).

‘hh.MM’ from 0.00 to 99.59 (-19.59) ‘MM.SS’ from 0.00 to 99.59 (-19.59) ‘dd.hh’ from 0.00 to 99.23 (-19.23)

‘SSSS’ from 0 to 9999 seconds (-1999)‘SSS.S’ from 0 to 999.9 seconds (-199.9)‘SS.SS’ from 0 to 99.99 seconds (-19.99)

‘MMMM’ from 0 to 9999 minutes (-1999)‘MMM.M’ from 0 to 999.9 minutes (-199.9)‘MM.MM’ from 0 to 99.99 minutes (-19.99)

‘hhhh’ from 0 to 9999 hours (-1999)‘hhh.h’ from 0 to 999.9 hours (-199.9)‘hh.hh’ from 0 to 99.99 hours (-19.99)

Direction (‘dIr’) - Value ‘uP’ / ‘doWn’. Select ‘uP’ to count time in ascending mode or ‘doWn’ for descending mode. On down mode, when reaching 0, instrument can be configured to stop or to continue in the negative range.

Preset (‘PrSt’) - Select the preset value. The preset value loads on display when reset function is activated.

1.14.1 Function

Front reset (‘F.rSt’) - Value ‘on’ / ‘oFF’. Select ‘on’ to activate the reset function when front key ‘LE’ (3) is pressed. Select ‘oFF’ to deactivate the front reset (pressing the ‘LE’ key will perform no action).

On power-up (‘on.Pu’) - Actions to apply when instrument restarts (at power up and when leaving ‘configuration menu’). The start up sequence is as follows : instrument starts in ‘Stop’ mode, applies the delay indicated in the ‘dLAy’ parameter, applies a reset as indicated in the ‘rSt’ parameter, applies ‘Start’ or ‘Stop’ as indicated in the ‘StAt’ parameter, then senses inputs ‘A’, ‘B’ and ‘R’.

Delay (‘dLAy’) - Value from 1 to 99 seconds. This delay is applied to the start-up sequence of the instrument.

Reset (‘rSt’) - Value ‘on’ / ‘oFF’. Select ‘on’ to load preset value on instrument start-up.

State (‘StAt’) - Value ‘Strt’ / ‘StoP’. Applies a ‘Start’ or ‘Stop’ function to the start-up sequence.

Flash (‘FLSh’) - Activates the flashing mode on display when chronometer is on ‘Stop’ and/or ‘Start’ mode.

Flash on stop (‘StP.F’) - Value ‘on’ / ‘oFF’. Configures flashing display when chronometer is stopped.

Flash on start (‘Str.F’) - Value ‘on’ / ‘oFF’. Configures flashing display when chronometer is counting.

1.14.2 Configuration

Function ‘B’ (‘Fn.b’) - Selects and activates the ‘B’ function.

Configure ‘B’ function - Configuration parameters for the ‘B’ function selected (see section 1.14.3).

1.14 Configuration menu descriptions

Note - input ‘B’ functions activate connections mode ‘Con.2’ (see section 1.7).

Function b.1 (‘fn.b.1’) - Controls up / down chronometer. Without configuration parameters. Input ‘B’ in high level (‘1’) activates up counting. Input ‘B’ in low level (‘0’) activates down counting.

Function b.2 (‘fn.b.2’) - Cycle counter. Enables internal counter called ‘cycle counter’ (from 0 to 9999). The ‘cycle counter’ is read on display by activating input ‘B’. Events that add ‘+1’ to the ‘cycle counter’ are:

Alarm1 (‘o.AL1’) - Value ‘on’ / ‘oFF’. Select ‘on’ to add ‘+1’ to the cycle counter each time ‘alarm1’ activates.

Alarm2 (‘o.AL2’) - Value ‘on’ / ‘oFF’. Select ‘on’ to add ‘+1’ to the cycle counter each time ‘alarm2’ activates.

Reset (‘o.rSt’) - Value ‘on’ / ‘oFF’. Select ‘on’ to add ‘+1’ to the ‘cycle counter’ each time the reset function activates (front reset, rear reset or alarm reset).

Function b.3 (‘fn.b.3’) - Accumulated time. Enables an in-ternal chronometer called ‘accumulated time’. The reading format is (by default) the same as the main chronometer, and is also configurable to ‘hh.mm’ or ‘mm.ss’ or ‘dd.hh’. Accumulated time is read on display by activating input ‘B’. The ‘accumulated time’ chronometer can be configured to count the total time the instrument has been working, the total time the instrument has been counting, or the total time the instrument has been stopped.

Format (‘Form’) - Value ‘ch.A’, ‘hh.mm’ / ‘mm.ss’ / ‘dd.hh’. Reading format for the accumulated time.

Count (‘cnt’) - Value ‘ALWS’ / ‘Strt’ / ‘StoP’. Select ‘ALWS’ to count when instrument is powered. Select ‘Strt’ to count when main chronometer is counting (‘Start’). Select ‘StoP’ to count when main chronometer is stopped (‘StoP’).

To reset the ‘accumulated time’ chronometer, show the value on display and press reset (front or rear).

1.14.3 Input ‘B’ functions

Page 12: Panel Meters Series SPanel meter 72x36mm chronometer Configurable chronometer and time counter. Selectable reading in 12 different formats, with hours, minutes, seconds and days, in

User’s Manual S40-CR

FEMA ELECTRÓNICA - Page 12

Configuration menu for 2 alarms on the chronometer. Each alarm can control a relay R1 (see section 2.1) optional and installable at slots ‘Opt1’ and ‘Opt2’. (Special module R4 allows for up to 4 simple relay outputs. See section 2.3 for more information).

Alarm mode (‘Mode’) - Value ‘oFF’ / ‘norM’ / ‘rEPt’. Select ‘oFF’ to deactivate this alarm. Select ‘norM’ for ‘normal’ mode. Select ‘rEPt’ for ‘repeat’ mode’. See section ‘1.5 Alarm modes’ for more information on each mode.

Type (‘tYPE’) - Value ‘MAX’ / ‘MIn’. Defines the behavior of the alarm as maximum or minimum alarm. The alarms con-figured as maximum are activated when the display value is equal or higher than the setpoint. The alarms configured as maximum are deactivated when the display is lower than the setpoint. The alarms configured as minimum have the inverse behavior.

Setpoint (‘SEt’) - Alarm setpoint.

Delay 1 (‘dEL.1’) - Value from ‘0.0’ to ‘99.9’ seconds. Deacti-vation delay for the alarm. Relay and front led are deactivated X seconds after alarm deactivation.

Setpoint2 (‘SEt2’) - Second setpoint. The second setpoint allows for the creation of activation windows. If the alarm is configured as maximum with setpoint 15.00 and setpoint2 at 45.00, the alarm will be activated between 15.00 and 45.00 and deactivated when display is <15.00 and >45.00.

On Alarm (‘on.AL’) - Value ‘cont’,’to.0’, ‘to.p’, ‘stop’. Behavior when setpoint is reached.

Select ‘cont’ to continue counting

Select ‘to.0’ to do a reset to ‘0’ and continue counting. Parameter ‘dEL.1’ (Deactivation delay) automatically con-figures to 1 second.

Select ‘to.p’ to load preset value and continue counting. Parameter ‘dEL.1’ (Deactivation delay) automatically con-figures to 1 second.

Select ‘stop’ to stop counting.

Alarm Flash (‘AL.FL’) - Value ‘on’ / ‘oFF’. Select ‘on’ to activate flash when alarm is activated. Flash remains active until next interaction with the instrument (keypad is pressed or any change on inputs ‘A’, ‘B’ or ‘R’).

1.14.5 Menu Alarms

Function b.4 (‘fn.b.4’) - Exceeded time. Enables an internal chronometer called ‘exceeded time’ chronometer. The read-ing format is (by default) the same as the main chronometer, and is also configurable to ‘hh.mm’ or ‘mm.ss’ or ‘dd.hh’. Exceeded time is read on display by activating input ‘B’. The ‘exceeded time’ chronometer is configured to start counting when the configured alarm is activated.

Format (‘Form’) - Value ‘ch.A’, ‘hh.mm’ / ‘mm.ss’ / ‘dd.hh.mm’. Reading format for the exceeded time.

Start (‘Strt’) - Value ‘o.AL1’ / ‘o.AL2’. Select the alarm event that will force the ‘exceeded time’ chronometer to start counting.

To reset the ‘exceeded time’ chronometer, show the value on display and press reset (front or rear). This reset leaves the ‘exceeded time’ chronometer with 0 value and in ‘Stop’ mode.

Function b.5 (‘fn.b.5’) - Main chronometer with display ‘hold’. Activate input ‘B’ to hold the reading of the chronome-ter. Chronometer still works on background. Deactivate input ‘B’ to recover the actual reading value of the chronometer.

Function b.6 (‘fn.b.6’) - Time counter with function to save memory of maximum and minimum durations of a cycle. Signal ‘Reset’ updates the max and min memories. Signal ‘B’ applies a reset to both memories. For applications to measure production times, and save a record of the maximum and minimum duration of a production cycle.

Configures the instrument to adapt to the sensors connected to inputs ‘A’, ‘B’ and ‘R’.

Pulls on channels ‘A’ and ‘B’ (‘PuL.S’) - Value ‘no’, ‘P.uP’ or ‘P.dn’. Select ‘P.uP’ to activate the pull-up resistor on inputs ‘A’ and ‘B’. Select ‘P.dn’ to activate the pull-down resistor on inputs ‘A’ and ‘B’. Select ‘no’ to deactivate pulls on inputs ‘A’ and ‘B’. Trigger is automatically set to 2,5V (trigger level 20) when ‘P.uP’ or ‘P.dn’ are selected.

Pull on reset (‘PuL.r’) - Value ‘no’, ‘P.uP’ or ‘P.dn’. Select ‘P.uP’ to activate the pull-up resistor on input ‘R’. Select ‘P.dn’ to activate the pull-down resistor. Select ‘no’ to deactivate pulls on input ‘R’. Trigger level for channel ‘R’ is fixed to 2.5V.

Trigger (‘trIG’) - Value from 0 to 31 (0 to 3.9Vdc). Select trig-ger level, shared for inputs ‘A’ and ‘B’. Each level represents 0.128 Vdc. Trigger level for input ‘R’ is fixed at value to 2,5V. See section 1.6 for description on utility ‘Trigger Sense’.

Activation for inputs ‘A’ and ‘B’ (‘Act.S’) - Value ‘on_h’ / ‘on_0’. Select ‘on_h’ to activate signals ‘A’ and ‘B’ on rising edge (mode ‘Con.1) or high level (mode ‘Con.2’). Select ‘on_0’ to activate signals ‘A’ and ‘B’ on falling edge (mode ‘Con.1’) or low level (mode ‘Con.2’).

Activation for reset (‘Act.r’) - Value ‘on_h’ / ‘on_0’. Select ‘on_h’ to activate input ‘R’ on rising edge (or high level). Select ‘on_0’ to activate input ‘R’ on falling edge (or low level). Front reset is always controlled by state (pressed / not pressed). Rear reset can be controlled by state or by edge, configu-

1.14.4 Menu Sensor

1.14 Descripción de los menús de configuración (cont.)

rable on menu entry ‘Tools / r.rSt’. By default rear reset is controlled by edge.

Excitation voltage (‘V.Exc’) - Select value for excitation voltage between 5V, 9V, 15V and 18V. Select ‘no’ to disable excitation voltage.

Antirrebound filter (‘rbnd’) - Value from 0 to 1000 mSec. For mechanical contact controls set value at 100mSeconds. When an impulse is received, the filter activates and no new impulses are counted for the duration of the filter value. When the filter time is over, next impulse received is counted and filter activates again. Affects to inputs ‘A’, ‘B’ and ‘R’.

Page 13: Panel Meters Series SPanel meter 72x36mm chronometer Configurable chronometer and time counter. Selectable reading in 12 different formats, with hours, minutes, seconds and days, in

User’s Manual S40-CR User’s Manual S40-CR

FEMA ELECTRÓNICA - Page 13

Configuration of non usual parameters and special tools.

Key UP (‘K.uP’) - Configuration of the information accessible with key UP (5). Select ‘on’ to activate desired entries. Press-ing key UP (while in normal working mode), will visualize each one of the parameters selected.

‘ALr1’ - Alarm1 setpoint. Value can be modified.

‘ALr2’ - Alarm2 setpoint. Value can be modified.

‘MAX’ - Visualization of memory of maximum. Press UP (5) while the value is on display gives access to the func-tion ‘RSt’. Press SQ (<) while ‘RSr’ will reset the memory of maximum.

‘MIn’ - Visualization of memory of minimum. Press UP (5) while the value is on display gives access to the function ‘RSt’. Press SQ (<) while ‘RSr’ will reset the memory of minimum.

‘cYcL’ - Total cycles, at special function Fn.b.2

‘PrSt’ - Preset value. Value can be modified. Reset is ac-tivated when Preset is changed (reading jumps to preset value)

Rear reset (‘r.rSt’) - Value ‘EdgE’ / ‘LEVL’. Select ‘EdgE’ to control rear reset by edges. Select ‘LEVL’ to control rear reset by levels.

Left Zero (‘LZEr’) - Value ‘on’ / ‘oFF’. Select ‘on’ to visualize left zeros.

Password (‘PASS’) - Select a 4 digit number to act as pass-word. This password will be requested when entering the ‘Configuration Menu’ (key SQ <). To deactivate the password select ‘oFF’.

Factory configuration (‘FAct’) - Factory default configura-tion. Select ‘yES’ to activate the factory default configuration.

Version (‘VEr’) - Firmware version installed..

Light (‘LIGh’) - Brightness. Select between 5 predefined levels of brightness.

1.14.6 Menu Tools

Menu entries ‘oPt1’ and ‘oPt2’ give access to the configura-tion menus for the optional modules installed on slots ‘Opt1’, and ‘Opt2’. This menu depends on the installed option. If there is no option installed the instrument shows “nonE”. Relay modules ‘R1’ are controlled from the standard alarm menu (see section 1.14.5).

1.14.7 Menu OptX - Options

Function (‘Func’) Reading format (‘View’) MM.SS Direction (‘dIr’) ‘uP’ Preset (‘PrSt’) 00.00

Configuration (‘conF’) Front reset (‘F.rSt’) ‘on’ (enabled) On Power-Up (‘on.Pu’) Delay (‘dLAY’) 0 Reset (‘rSt’) ‘oFF’ State (‘StAt’) ‘StoP’ Flash (‘FLSH’) Flash on Stop ‘oFF’ Flash on Start ‘oFF’ Input ‘B’ function (‘Fn.b’) ‘no’ (disabled)

Sensor (‘SnSr’) Pulls on ‘A’ and ‘B’ (‘PuL.S’) ‘P.uP’ (pull-up) Pull on ‘R’ (‘PuL.r’) ‘P.uP’ (pull-up) Trigger (‘trIG’) 20 (2,5Vdc) Activation for ‘A’ and ‘B’ (‘Act.S’) ‘on_0’ (falling edge) Activation for ‘R’ (‘Act.r’) ‘on_0’ (falling edge) Excitation voltage(‘V.EXc’) 15Vdc Antirrebound filter (‘rbnd’) 0 mSec.

Alarms 1 and 2 Mode (‘ModE’) ‘oFF’ (disabled) Type maximum alarm Setpoint 0 Deactivation delay 1.0 seconds Setpoint 2 Off On Alarm continue Alarm Flash ‘oFF’

Tools (‘TooL’) Key UP (‘K.UP’) Setpoint on alarm1 Off Setpoint on alarm2 Off Maximum Off Minimum Off Cycle Off Preset Off Rear reset by edges Left zeros Off Password Off Brightness 3

1.15 Default factory configuration

Page 14: Panel Meters Series SPanel meter 72x36mm chronometer Configurable chronometer and time counter. Selectable reading in 12 different formats, with hours, minutes, seconds and days, in

User’s Manual S40-CR

FEMA ELECTRÓNICA - Page 14

The instrument can display the following messages and errors.“Err.1” Password entered is not correct.“Err.2” The instrument has detected an installed option but was unable to communicate.“Err.8” The instrument is limiting the current at Vexc.“9999” + flash. The display is in overrange (real display should be higher than 9999 and can not be displayed).“-1999” + flash. The display is in underrange (real display should be lower than -1999 and can not be displayed).“E.101” Option is installed but the type can not be recog-nized.

1.17 Messages and errorsYou may need to access the inside of the instrument to insert additional modules. Use a flat screwdriver to unlock the upper clips marked with “A”. Then unlock the lower clips marked with “B” and remove the front cover. Let the inside of the instrument slide out of the housing.

To reinsert the instrument make sure that all modules are correctly connected to the pins on the display module. Place all the set into the housing, assuring that the modules cor-rectly fit into the internal guiding slides of the housing. Once introduced, place again the front cover by clipping first the upper clips “A” and then the lower clips “B”.

Important - If your instrument was delivered with the IP65 front seal option, accessing the inside of the instrument will perma-nently break the IP65 seal on the areas of clips “A” and “B”.

1.16 Accessing the instrument

Risk of electric shock. Removing the front cover will grant access to the internal circuits. Disconnect the input signal to prevent electric shock to the operator. Operation must be performed by qualified personnel only.

A

B

Page 15: Panel Meters Series SPanel meter 72x36mm chronometer Configurable chronometer and time counter. Selectable reading in 12 different formats, with hours, minutes, seconds and days, in

User’s Manual S40-CR User’s Manual S40-CR

FEMA ELECTRÓNICA - Page 15

All instruments are warranted against all manufacturing defects for a period of 24 MONTHS from the shipment date. This warranty does not apply in case of misuse, accident or manipulation by non-authorized personnel. In case of mal-function get in contact with your local provider to arrange for repair. Within the warranty period and after examination by the manufacturer, the unit will be repaired or substituted when found to be defective. The scope of this warranty is limited to the repair cost of the instrument, not being the manufacturer eligible for responsibility on additional damages or costs. .

1.18 Warranty

1.19 Installation precautions

This instrument has been designed and verified according to the 61010-1 CE security regulation, and is designed for applications on industrial environ-ments. See the “CE Declaration of Conformity” further in this document for information on the category of measure and the degree of pollution levels that apply.

Installation of this instrument must be performed by qualified personnel only. This manual contains the appropriate information for the installation. Using the instrument in ways not specified by the manufacturer may lead to a reduction on the specified protection level. Disconnect the instrument from power before starting any maintenance and / or installation action.

The instrument does not have a general switch and will start operation as soon as power is connected. The instrument does not have protection fuse, the fuse must be added during installation.

The instrument is designed to be panel mounted. An appropriate ventilation of the instrument must be assured. Do not expose the instrument to excess of humidity. Maintain clean by using a humid rag and do NOT use abrasive products such as alcohols, solvents, etc.

General recommendations for electrical installations apply, and for proper functionality we recommend : if possible, install the instrument far from electrical noise or magnetic field generators such as power relays, electri-cal motors, speed variators, ... If possible, do not install along the same conduits power cables (power, motor controllers, electrovalves, ...) together with signal and/or control cables.

Before proceeding to the power connection, verify that the voltage level available matches the power levels indicated in the label on the instrument.

In case of fire, disconnect the instrument from the power line, fire alarm according to local rules, disconnect the air conditioning, attack fire with carbonic snow, never with water.

Risk of electrical shock. Instrument terminals can be connected to dangerous voltage.

Instrument protected with double isolation. No earth connection required.

Instrument is in conformity with CE rules and regulations. See “CE Declaration of Conformity” further in this document.

Manufacturer FEMA ELECTRÓNICA, S.A. Altimira 14 - Pol. Ind. Santiga E08210 - Barberà del Vallès BARCELONA - SPAIN www.fema.es - [email protected]

Products - S40-CR

The manufacturer declares that the instruments indicated comply with the directives and rules indicated below.

Directive of electromagnetic compatibility 2004/108/CEEDirective of low voltage 73/23/CEE

Security rules 61010-1Equipment “Fixed” “Permanently connected”Pollution degree 1 and 2 (without condensation) Isolation Double

Emission rules61000-6-4 Generic rules of emissionImmunity rules61000-6-2 Generic rules of immunity61000-4-2 By contact ±4KV - Criteria B On air ±8KV - Criteria B

61000-4-3 Criteria A61000-4-4 On AC power lines: ±2KV - Criteria B On DC power lines: ±2KV - Criteria B On signal lines : ±1KV - Criteria B

61000-4-5 Between AC power lines ±1KV - Criteria B Between DC power lines ±0.5KV - Criteria B

61000-4-6 Criteria A61000-4-8 30A/m at 50Hz - Criteria A61000-4-11 0% 1 cycle Criteria A 40% 10 cycle Criteria B 70% 25 cycle Criteria B 0% 250 cycle Criteria B

Barberà del Vallès October 2013Daniel Juncà - Quality Manager

1.20 CE declaration of conformity

Page 16: Panel Meters Series SPanel meter 72x36mm chronometer Configurable chronometer and time counter. Selectable reading in 12 different formats, with hours, minutes, seconds and days, in

User’s Manual S40-CR

FEMA ELECTRÓNICA - Page 16

Relay type 3 contacts (Common, NC, NO)Maximum current 8A (resistive load)Voltage 250 Vac continuouslyInstallable at Option1 and/or Option2

Output 4/20mA, 0/10Vdc selectableAccuracy 0.1% FSIsolated yes, 1000VdcThermal drift 50 ppm/ºC for Vdc 60 ppm/ºC for mAInstallable at Option1 and/or Option2

Module with 1 analogue output. Configurable 4/20mA or 0/10Vdc. Output signal proportional to the reading. Scaling through the frontal keypad. Up to a maximum of two AO modules can be installed in one S Series panel meter. For more information see document 2657_S40_OPTIONAL_MODULES at www.fema.es

Module with 1 relay. Up to a maximum of two R1 modules can be installed in one S Series panel meter. For more relay output needs, check special modules R2 and R4. For more information see document 2657_S40_OPTIONAL_MOD-ULES at www.fema.es

2. Output and control modules2.1 Module R1 2.2 Module AO

Opt 2Opt 1

Terminal A CommonTerminal B NO - Normally OpenTerminal C NC - Normally Closed

PowerSignal

A B C A B C

Opt 2Opt 1

Jumper M mode mAJumper V mode VdcTerminal A Vexc (+13.8Vdc @25mA)Terminal B Signal output (mA or Vdc)Terminal C GND

PowerSignal

A B CM V A B CM V

Page 17: Panel Meters Series SPanel meter 72x36mm chronometer Configurable chronometer and time counter. Selectable reading in 12 different formats, with hours, minutes, seconds and days, in

User’s Manual S40-CR User’s Manual S40-CR

FEMA ELECTRÓNICA - Page 17

Special modules with 2 and 4 relays. Use special modules R2 or R4 when standard R1 modules do not provide re-quired functionality for your application. Only one special module R2 or R4 can be installed in an S Series panel me-ter. Special modules R2 and R4 are not compatible with R1 modules.Configuration is done through the OPTx entry of the con-figuration menu. Functionality for R2 and R4 modules differs from standard R1 modules. For more information see docu-ment 2657_S40_OPTIONAL_MODULES at www.fema.es

Number of relays 2, or 4Relay type 3 contacts (Common, NO, NC)Maximum current 6A (resistive load) (each relay)Voltage* 250 Vac continuouslyInstallable at slot Opt.1. R2 fills OPT1 R4 fills OPT1 and OPT2Terminal Plug-in screw terminals pitch 3.81mm* Terminals approved for 300V (according to UL1059, groups B and D) and 160V (according to VDE in CAT-III and pollution degree 3).

Terminal A Relay1 CommonTerminal B Relay1 NO - Normally OpenTerminal C Relay1 NC - Normally ClosedTerminal D Relay2 CommonTerminal E Relay2 NO - Normally OpenTerminal F Relay2 NC - Normally ClosedTerminal G Relay3 ComúnTerminal H Relay3 NO - Normally OpenTerminal I Relay3 NC - Normally ClosedTerminal J Relay4 CommonTerminal K Relay4 NO - Normally OpenTerminal L Relay4 NC - Normally Closed

2.3 Modules R2, R4

PowerSignal

A B C D E F G H I J K L

R2

Opt 2Opt 1

R4

Page 18: Panel Meters Series SPanel meter 72x36mm chronometer Configurable chronometer and time counter. Selectable reading in 12 different formats, with hours, minutes, seconds and days, in

User’s Manual S40-CR

FEMA ELECTRÓNICA - Page 18

3. More options and accessories

3.2 Option IP65This option provides M series panel meters with IP65 front protection. The instrument is provided with the front cover sealed. Important - Removing the front cover to access the inside of

the instrument will permanently disable the IP65 protection (see section 1.18).

3.1 Option GGreen led option.

Green led

Page 19: Panel Meters Series SPanel meter 72x36mm chronometer Configurable chronometer and time counter. Selectable reading in 12 different formats, with hours, minutes, seconds and days, in

User’s Manual S40-CR User’s Manual S40-CR

FEMA ELECTRÓNICA - Page 19

T H I S P

A GE B

L A N K

Page 20: Panel Meters Series SPanel meter 72x36mm chronometer Configurable chronometer and time counter. Selectable reading in 12 different formats, with hours, minutes, seconds and days, in

Large Displays60&100mm digit

Signal Converters& Isolators

Panel MetersStandard 96x48mm

other products

ELECTRONIC INSTRUMENTATION FOR INDUSTRY

www.fema.es

FEMA ELECTRÓNICA, S.A.Altimira 14 - Pol. Ind. SantigaE08210 Barberà del VallèsBARCELONA - SPAIN

Tel. (+34) 93.729.6004 - www.fema.esFax (+34) 93.729.6003 - [email protected]

Bar Meters

Panel MetersMiniature 48x24mm

Panel MetersSmall 72x36mm