Upload
others
View
11
Download
0
Embed Size (px)
Citation preview
Tel : +91 4546 - 251020, 250076, Fax : +91 4546 - 253060, Mobile : +91 96009 92069
Email : [email protected] | Website : www.monarchindia.net
Maintenance, Repair& Overhaul (MRO) for Mechanical & Electrical Engineering
Ø
Ø
Ø
Ø
Ø
Metal Reclamation Putties
Maintenance Coatings
Emergency Maintenance kits
Industrial Maintenance Aerosols
Oil, Grease & Lubricants
Ø
Ø
Pipe repair & Strengthening Kits
Metal Epoxy Sticks
Ø
Ø
Ø
Ø
Ø
Ø
Anti-Corrosive Coatings
Marine Coatings
High Temperature Coatings
Maintenance Coatings
Hand Cleaners & Barrier Creams
Wear Protection Solutions
Repair/ Maintenance/
Protection of
Machinery & Equipments
Arresting of Online / Offline
Leakages & Strengthening
of Wall Thickness
Protective Coatings
Ø
Ø
Pump Efficiency Improvement Coatings
Thermal Insulation Coatings
ØCrusher Backing CompoundØ
Ø
Ø
Passive Fire Protection Coatings
Self Fusing Insulation Tapes
Electro Static Dissipative (ESD) &
Insulation Resistance (IR) Coatings
Efficiency Improvement /
Thermal Insulation
Epoxy Crusher Backing Electrical Safety
www.monarchindia.net | Toll - Free : 1800 - 425 - 1070
Passive Fire Protection Coatings
Passive Fire Protection Coatings
How Monarch’s FlameGuard coating protects in the event of fire?
Personnel protection – giving people time to escape or shelter from the effects of the fire Asset
protection – minimizing damage to the assets before f ire services arriving.
Fire strikes when least expected.The speed at which the fire travels or propagates even a
small accidental fire or electric spark caused by short circuit is sufficient to create huge,
immeasurable damage to the safety of people and properties.The fire can start from external source
or internal source, just from anywhere and without warning. Fire takes advantage of unprotected
surfaces and areas concealed from fire fighters. The consequences - overwhelming heat, suffocating smoke, loss of time,
damage to items of sentimental value and above all, the loss of life. The insurance company may able to replace the
material goods, but there are few things that money simply cannot replace.
The conventional paints coated over structural steel, concrete and wooden surfaces are flammable and indeed act
as a fuel which aid in spreading of fire. The intense heat conducted through metal ignites the paint and combust
spontaneously even if not subjected to a f lame directly. In the event, of f ire , the winning time is crucial in evacuating the
people and limiting the amount of structural damage.There is no second chance with the fire. One has to do it right first time.
Monarch's FlameGuard fire retardant intumescent coatings offer
ultimate protection in extensive applications like Industries, Institutions,
Corporate houses, Show rooms, Residences, Schools, Dormitories, Hospital
Care, Nursing Homes, Hotels, Motels, Retail stores, Restaurants, Transportation
etc., on structural steel, concrete, cables, wood, rubber, PVC, canvas, gypsum
board, polyurethane foam, wooden surfaces, joists, beams, acoustic tile, rough
and finished timbers, open surface panel board, previously painted wall board,
hard woods, softwoods, drywall, SPF plywood and OSB etc.,
This coating after application dries quickly to a matt finish . On contact with fire or excessive heat, the coating
puffs up (intumesces) to several times thicker than original coating film, forming a sponge - like cellular foam
insulating char layer and reduces available oxygen to the surface. Intumescent is a substance which swells as a result of
heat exposure, thus increasing in volume, and decreasing in density. An insulating char of low thermal conductivity that
reduces heat transfer to substrate and slows the temperature rise of the substrate. The product works by cutting off
oxygen from the fuel source inhibiting the combustion process in the immediate vicinity of the area and reduces
the transmission of fire, heat and smoke to the protected area like fire retardant jacket during and after exposure
to fire. Even after prolonged exposure to a fire the coating is not destroyed and continue to shield the
substrate by forming low conductivity carbon char that act as a barrier between the fire and the substrate. This
substantially decreases the temperature rise, smoke generation and finally insulates and protects the substrate from
the heat of the flame.
The rating of fire retardant coatings depends on the intensity of the flame, type, coating thickness and other
variables. More thickness of the coatings increases fire protection duration. The coating adheres tightly and fits to any
size and shape of the substrate. It produces neat, attractive and paintable finish. The coatings are non-toxic, asbestos
free and resist cracking or crumbling.
Fire protection is important for:
Name Code Pack Size Description
FlameGuard ZP- Primer
FlameGuard SSP- Base Coat
FlameGuard SSP- Top Coat
FlameGuard CP
FlameGuard CC
FlameGuard FRP
FlameGuard EIC
FlameGuard EFM
FlameGuard MWB
11601
11602
11603
11611
11621
11631
11641
11651
11652
4 Kg
5 Kg
1 Kg
5 Kg
1 Kg
5 Kg
5 Kg
25 Kg
1 No
Anti Corrosive Zinc Primer for Structural Steel Protection
Base coat for 30 Min - 120 Min Fire rating for Structural Steel Protection
Finish coat for 30 Min - 120 Min Fire rating for Structural Steel Protection
Fire Retardant Intumescent Coatings for Cable Protection
Fire Retardant Coatings for Wood Protection
Fire Resistive/Retardant Paints to delay Ignition/surface burning for
Interior Substrates
High performance epoxy intumescent f ire protection coating system
Expanding Fire Stop/Resistant Mortor
Fire Retardant Mineral Wool Board
Fire Retardant Intumescent Coatings for Structural Steel Protection
Fire Retardant Intumescent Coatings for Cable Protection
Fire Retardant Coatings for Wood Protection
Fire Resistive/Retardant Paints to delay Fire Ignition for 10 – 15 min
Epoxy Fire Resistant coatings offshore and onshore environments
Fire Resistant Mortar for Compartmentation against spread of Fire & Smoke
Range of Product
CABLE PROTECTION
FlameGuard CPIntumescent f ire protection coating for combustible single & bunched electrical cables
and cable trays
Long runs of unprotected, PVC or plastic rubber sheathed combustible
cables, usually supported by vertical or horizontal cable trays and holders, are
prone to rapid fire spread and excessive damage. Unprotected cables burn & propagate fire after only a few
minutes of exposure to fire. Power current for vital control functions, supplies and services fails very quickly.
Burning cable sheaths carry the fire rapidly forward as fast as 20 meters per minute. They gives off aggressive
vapors. The cable trays, if not protected, are exposed to the risk from melting and collapsing. Cables, cable trays
and holders protected with FlameGuard CP help prevent damage or keep it within reasonable limits. The time that
elapses before the current fails is increased many times. The indirect damage from cable fires (f ire travel,
breakdowns, corrosion resulting from harmful gases affecting sensitive instruments) is generally greater than the
f ire damage initially visible.
FlameGuard CP is a water-based intumescent coating which is designed to prevent ignition, flame
spread & smoke emission along the jacketing of electrical (or other) cables and to provide a thermal barrier for
protection against heat damage. FlameGuard CP will also prevent a short circuit within an electrical cable from
starting a fire and will help identify the location of such a short circuit by forming an intumescent char at the spot.
The coating can be applied to grouped cables or single cables. When exposed to flame or to a temperature above
175ºC, the coating forms a protective intumescent char. (This char should be removed completely and clean cables
should be recoated if intumescences should occur). The coating foams up under the effect of heat to form an
insulating layer.There is no subsequent burning of protected cables after the direct effect of fire has been halted.
The thermal conductivity of a FlameGuard CP coating that has not foamed is about the same as that of a
plastic cable sheath, which means that the higher temperature of the conductor is raised only insignif icantly in
cables protected with FlameGuard CP. As only a relatively thin coating is needed, it allows radiation of heat from
cables during operation. The current-carrying capacity remains virtually unchanged. The cured coating is flexible
and adapts to the usual movements and bending without flaking. Its premium latex binder system is totally
resistant to water and will not re-emulsify after drying. FlameGuard CP reduces the spread of flame in cable runs
and prevents the emission of hydrochloric gases in cable fires. The release of hydrochloric acids vapors is slowed
down considerably. Acid vapors that are released are neutralized.The upgradation of existing cables to the highest
grade of f ire safety is possible with the coating of FlameGuard CP. Additionally the thin film coatings will maintain
circuit integrity to small diametrical cables in restricted applications.
The coating of the entire length of cables to maintain the power supply to important equipment while
data are being saved or a fire extinguished (recommended dry film thickness 1.6 mm). Partial coating of cables
(4 m length @ every 10 m interval, recommended dry f ilm thickness of 1.6 mm) to prevent f ire from spreading
along cable runs.The cable joints and around cable crossing should be coated at 1.5 meter on both sides of joints.
Coverage: Single Cable - 1.75 Sq.m / 5 Kg @DFT 1.5 mm Thickness
Grouped /Bunched /Jacketed Cables - 1.43 Sq.m / 5 Kg @DFT 2 mm Thickness
Applications
FlameGuard CP Meets following specifications:
Electric Power Cables
Communication Cables
Fiber Optic Cables
Control Cables
Cable Conduits
Instrumentation Cables
Flammability Test – IEC 383 & 1S : 10810 part – 53 (30min / 1.5mm DFT)
Fire Resistance test – IEC : 331 (20min / 2.5mm DFT)
Fire Propagation Test – IS : 10810 Part – 61 (1.5 – 2mm DFT)
Scorching Test – IPSS 1-07-0 61 – 94 Standard
Cable Capacity Rating – IPSS 1-07-061-94 (3% max. No cable de-rating up to 2.5mm DFT.)
Smoke Density – ASTM 2843 (< 35%)
Limiting Oxygen Index – ASTM D863: 77.
Radiation Test – Gamma radiation test as per IEEE: 383.
Dielectric Strength – IPSS 1-07-061-94 (3kv/5min)
Flexibility – IS: 10810 part 50. (6 x D Bending radius)
Accelerated Ageing Test – IPSS 1-07-061-94 Standard
Leakage Current /High Potential Test at 200% of rated voltage
Ø
Ø
Ø
Ø
Ø
Ø
Ø
Ø
Ø
Ø
Ø
Ø
Ø
Ø
Ø
Ø
Ø
Ø
Ø
Ø
Ø
Ø
Ø
Ø
Junction / Crossings of Cable routes
Switch gears
Cable Trays
Racked Cables
High Rise Buildings
High Security Buildings
FlameGuard CP meets following specifications:
Fire Test on electrically heated cables via 150% of rated current.
Salt water immersion tests - ASTM E 1597
Single cable vertical flame propagation / burning test – IEC 332. Flame propagation test - Maximum
affected cable length should not reach within 50 mm of the edge of the top clamp.
Single cable horizontal fire survivability test – IEC 331. Fire survival test - Product should clear fire test
without any damage to cable core /current carrying capacity post 20 minutes fire exposure.
Single cable vertical flame self propagation test – IEC 383 Part 25. Single Vertical
cable fire self extinguishing test - Flame should not propagate & fire travel should be within test limits
Grouped electrical cable test - Product should clear test with DFT >1.6mm. Includes vertical fire tests,
scorch tests, leakage current /high potential test post 200% of rated voltage both pre & post fire tests,
fire tests on cables electrically heated with 150% of rated current, saltwater test, accelerated ageing test,
ampacity test & weather exposure tests
Ø
Ø
Ø
Ø
Ø
Ø
The electric distribution cables / wiring shall be laid in a separate duct. The duct shall be sealed at
every f loor with non-combustible materials having the same f ire resistance as the f ire rating of the cable duct.
The electric distribution cables / wiring shall be laid in a separate duct. The duct shall be sealed at
every f loor with non-combustible materials having the same f ire resistance as the f ire rating of the duct.
The outside walls, ceiling, floor, opening including door and windows to the transformer substation
area shall be provided with fire resistance of 2 hours rating.
When housed inside the building the transformer shall be of dry type and shall be compartmentised
from the other portion of the premises by walls / doors / cutouts having fire a minimum fire resistance of 4
hours.
Materials of class 4 f lame spread are the worst ones for use in building & hence their use is to be
strictly prohibited unless they are given proper fire retardant treatment.
Where the duct passes through fire walls, the opening around the duct shall be sealed with f ire
resistant materials having the fire resistant rating of the compartment. Where the duct crosses the
compartment which is fire rated, the duct shall be fire rated for same fire rating. Further, depending on the
services passing around ductwork, which may be affected in case of fire temperature rising, the ducts shall be
insulated.
Annex Clause C1.12 Fire Stopping Cables/Ducts/Penetrations
Annex Clause C1.12a Cable/Ducts
Annex Clause C1.16a Transformer Substation
Annex Clause C1.16C Transformer Room
Clause F.3.4.15.4 Class 4 Materials
Annex Clause C1.17 Fire Rated Ducts
NATIONAL BUILDING CODE OF INDIA 2005
þ
þ
þ
þ
þ
þ
(Revised Building Code of India, Firestop Guidelines - excerpts from Part 4 : Fire and Life Safety)
STRUCTURAL STEEL PROTECTION
FlameGuard ZP - Primer
FlameGuard SSP - Base Coat
FlameGuard SSP - Top Coat
Epoxy based zinc rich primer for fire protection coating for structural
steel.To protect steel against corrosion & prepare the surface.
During fire when the structural steel temperature approaches 538°C it lose 60% of its yield
strength and may lead to the building collapse. FlameGuard SSP Base Coat – coated to desired thickness prevents
steel structures from crossing the critical temperature of 538°C, thus delaying the collapse of loaded steel
structures for up to 2 hours and providing time for evacuation & fire fighting. The smooth fibre free robust
decorative surface allows the architect to use the structural steel work as an integral part of the building design.
Rapid installation with typically DFT's below 2mm, appearance of the structure is preserved without affecting the
load bearing calculations. In case of fire, the film expands to many times its original film thickness.This provides an
insulating foam-like coating or char to protect steelwork against heat build-up and the effects of fire.
Thin film high solids intumescent coating provide maximum protection & enables a high quality finish
to be obtained similar to conventional decorative paints. A hard decorative self-extinguishing, fast drying finish to
seal the basecoat & provide an attractive high quality finish. Recommended as a top coat over FlameGuard SSP
Base Coat for optical reasons and moisture protection. The coating facilitates as sealer function to prevent early
degradation and inactivation of intumescent layer. Available in various RAL shades.
21 Sq.m/ 4 kgs / @ DFT 125 micronsCoverage:
Coverage:
Coverage:
Coverage:
The factors influencing the specification:
Applications:
Type of section (open/closed/cellular profile)
Exposure (i.e. 3 sided, 4 sided exposure)
Massivity of Steel (Hp/A)
Fire Rating FR (30/ 60/ 90/ 120 min)
Critical Temperature (CT)
I Sections
Hollow Sections
Universal Sections
Cellular Beams & Columns
Exposed Steel Membranes
Angles, Channels, Truss, Tubes
Wall assemblies,
Floor/ceiling assemblies
Roof/ceiling assemblies
Structural Steel
Kitchens
False ceiling
Stairwells
Castellated Sections
Lift / Equipment Rooms
Electrical Cabins
Upgrading of concrete slabs
Ø
Ø
Ø
Ø
Ø
Ø
Ø
Ø
Ø
Ø
Ø
Ø
Ø
Ø
Ø
Ø
Ø
Ø
Ø
Ø
Ø
Ø
STEEL PROTECTION
FlameGuard ZP (Primer)
Steel Structural
FlameGuard SSP (Base Coat)
FlameGuard SSP (Top Coat)
F30 - 925 gms / Sq.m (DFT 500 microns).
F60 - 1850 gms / Sq.m (DFT 1000 microns).
F 30 - 8 Sq.m / 5 kgs @ DFT 320 microns
F 30 - 15 Sq.m/ 5 kgs @ DFT 180 microns
F90 - 2400 gms / Sq.m (DFT 1300 microns).
F120 - 3330 gms /Sq.m (DFT1800 microns)
FlameGuard SSP meets the following specifications:
Fire Resistance Test -BS 476 Part20- 21/ ASTM E 119-08
Surface Burning Characters -ASTM E 84
Flame Spread Rate - ASTM E 84
Smoke Development -ASTM E 84
Ø
Ø
Ø
Ø
The Hp/A value is known as the 'section factor' of the steel section.The section factor is directly related to
the heating rate of the steel section under a fire condition. The Hp/A value can be calculated from the size of the
section.
The larger the surface area relative to the cross sectional area, the higher the Hp/A value. The higher the
Hp/A value, the more material required.
Therefore, as a general rule: The thicker the section, the slower it is to heat up, and consequently the less
thickness of material required
For example: Hp = The perimeter of the steel exposed to the fire
A = The cross sectional area of the section
BUILDING INTERIOR & EXTERIOR PROTECTION
FlameGuard FRP
Fire Resistive/Retardant Paints to delay ignition/surface burning for
Interior & Exterior Substrates
FlameGuard FRP is premium quality water based, nontoxic thin film fire retardant paint formulated to
delay ignition for 10-15 minutes and reduce surface burning rate of interior substrates, including gypsum board,
composite architectural panels, oriented strand board and other wood products. This product is suitable for
residential/multifamily, commercial for both new and reconstruction projects
10 Sq.m/ 5 Kg @ 250 Mic DFTCoverage:
SECTION FACTOR
The product is a high build, two pack material providing excellent
durability combined with excellent corrosion and fire protection for a long
period of time for structures, pipe work, vessels and fire resistant divisions from
the effects of hydrocarbon pool and jet fires caused due to petrol, diesel, petrochemicals and gases, cellulosic fire
etc., primarily intended for use in high risk environments such as oil, gas, petrochemical and power generation
industries. Suitable for both offshore and onshore environments. The coating thickness required for protection is
normally specified in the range of 4-20 mm. To be used as mid coat as part of a complete system in atmospheric
environments followed by weather resistant aliphatic polyurethane finish coat, MonoGuard PCG. The coating
facilitates as sealer function to prevent early degradation and inactivation of intumescent layer. Depending on the
actual exposure of the coating system, various primers and topcoats can be used in combination with this product.
FlameGuard EICHigh performance epoxy intumescent fire protection coating system
Fire Retardant Intumescent Clear Coating
Coverage:
FlameGuard EIC Meets the following specifications
ISO22899 - Jet fire test
ISO20340 - Performance requirements for protective paint systems for
offshore and related structures.
Ø
Ø
Applications:
Floating Production Storage & Off-shore loading Vessels (FPSO)
Refineries
Petrochemical plants
Liquified Natural Gas (LNG) terminals
Liquified Petroleum Gas (LPG) storage facilities
Ø
Ø
Ø
Ø
Ø
WOOD PROTECTION
FlameGuard CC
Single component, chlorinated water resistant intumescent clear
coating that contains highly effective fire retardants to reduce flame spread
during the event of fire. The coating can be used over painted surfaces, fiber
insulation, polyurethane foam, wood, and other combustible surfaces without compromising on aesthetic appeal.
On curing it forms a clear, non-yellowing, water resistant fire retardant f inish that protects the substrate from
combustion and heat. The coated surface retains its original appearance and in addition protected by the water &
weather resistant properties.
2 Sq.m/ Kg / 2 CoatsCoverage:
Base Coat - FlameGuad ZP - Primer
Intermediate / Mid Coat - FlameGuard EIC
Top Coat - MonoGuard PCG - Aliphatic Polyurethane top coat
v
v
v
5 Sq.m/ 5kgs @ 1 mm
Applications:
Applications:
Painted, Stained or Varnished wood
Softwood
Hardwood
MDF (FR & non-FR),
Melamine faced
Shutter (plywood or dense mineral wool board).
Secondary reinforcement where necessary.
Ducts – Fire rated, with Damper
Pipes – Plastic, Steel or Cast Iron, Non Ferrous Metals
Cables – Single Cables, Cable bundles, Cable trays, Cable Conduits
Plywood
Particle board
Bamboo
Painted canvas on plasterboard
Ø
Ø
Ø
Ø
Ø
Ø
Ø
Ø
Ø
Ø
Ø
Ø
Ø
Ø
FIRE COMPARTMENTATION AT ELECTRICAL & MECHANICAL SERVICE
PENETRATIONS THROUGH WALLS, CEILINGS & FLOORS
FlameGuard EFM
When fire resisting compartments are created to contain fire and smoke
from spreading within building structures, this also presents a parallel threat as
most concealed activities between fire resisting walls and f loors are interlinked.
The importance of sealing gaps in this type of construction is therefore vital to ensure the compartmentation
systems work to their maximum ability to save life and property. Such gaps are typically at service penetrations
through walls and floors, but also include gaps left for structural movement and gaps left due to poor
workmanship. The integrity failure occurs when cracks, holes or openings occur through which flames or hot
gases can pass. Insulation failure occurs when temperature rise on the unexposed surface of the service, on the
unexposed face of the building element 25mm from the penetration or the seal itself exceeds 180°C . FlameGuard
EFM plays an major role in maintaining integrity and insulation.
FlameGuard EFM Mortar is a fire rated load bearing system providing up to 4 hours (for 200 mm
thickness) fire protection to compartment walls, ceilings and floors around large electrical and mechanical
through service penetrations like HVAC ducts, plastic pipes, and where electrical services have been installed.
Whilst curing, the mortar expands by approximately 1 % ensuring a tight seal around penetrations and within the
opening. It is designed to maintain the fire resistance of compartment walls and floors. When mixed with water it
can be poured or troweled into service penetration openings preventing the passage of flame, smoke and toxic
gases for periods of up to 4 hours for 200 mm thickness and thermally insulating f ire seal.The mortar is pre – mixed
dry blend, consisting of inorganic fillers and foamed perlite.
Fire Stop Mortar for fire compartmentation by sealing service penetrations
F-120(2 Hours) - 0.294 Sq.m/ 25 Kg @ DFT 100 mm T
F-240(4 Hours) - 0.147 Sq.m/25 Kg @ DFT 200 mm T
Coverage:
Fire Retardant Mineral Wool Board
MINERAL WOOL BOARD
FlameGuard MWB
FlameGuard MWB is a fire & heat resistant mineral wool boards coated
on both sides with FlameGuard CP intumescent coating, affixed with FlameGuard
EFM expanding sealant, to prevent the passage of fire and smoke and the transfer
of heat. Final aesthetic protective top coating of FlameGuard FRP for moisture protection. It is specif ically
designed for sealing around cable & service penetrations in walls and floors.
Dimension:
Outer Boards – 2 x 595mm x 1195mm x 23mm (Each Board 0.71 Sq mtrs). Size subject to change.
Infill Rockwool Insulation pre – coated with FlameGuard Intumescent coatings > 1mm DFT – 4x 1mtr x
0.50mtr x 50mm (0.50 sq mtr each infill insulation panel).
Ø
Ø
NATIONAL BUILDING CODE OF INDIA 2005
þ
þ
þ
þ
þ
þ
(Revised Building Code of India, Firestop Guidelines - excerpts from Part 4 : Fire and Life Safety)
Load bearing steel beams & columns of buildings having total covered area of 500m2 and above
shall be protected against failure /collapse of structure in case of f ire.
The building shall be suitably compartmentalized so that the fire and smoke remain confined to
the area where the fire incident has occurred and does not spread to the other part of the building.
Service ducts and shafts shall be enclosed by walls of 2 hours and doors of 1 hour rating. All such
ducts / shafts shall be properly sealed and f ire stopped at all floors.
Openings in the separating walls or floors shall be fitted with 2hr fire resistance assemblies .
Openings in walls or floors which are provided for the passage of all building services like cables,
electrical wiring and telephone cables etc., shall be protected by enclosures in the form of Duct / Shafts with a
fire resistance of not less than 2 hours.
Every vertical opening between the floors of a building shall be suitably enclosed or protected as
necessary to provide reasonable safety to the occupants while using means of egress by preventing spread
of fire, smoke or fumes through vertical openings from floor to floor, thus allowing occupants to complete
their safe use of the means of egress.
Clause 3.3.3 Steel Construction
Clause C-9 Compartmentation
Annex Clause C1.9 Fire Stopping Service Ducts & Shafts
Clause 3.4.8.2 Wall & Floor Openings
Clause 3.4.8.3 Fire Stopping Wall & Floor Openings
Clause 3.4.8.4 Fire Stopping – Vertical Openings
FIRES ARE CLASSIFIED BY THE TYPES OF
FUEL THEY BURN
Class A Fires consist of ordinary combustibles such as wood, paper, trash or anything else that
leaves an ash.
Class C Fires. Energized Electrical Fires are known as Class C fires.
Class K Fires are f ires that involve cooking oils, grease or animal fat.
Class D Fires are combustible metal f ires. Magnesium andTitanium are the most common types
of metal fires.
Class B Fires are fueled by flammable or combustible liquids, which include oil, gasoline, and
other similar materials.
Class A
Class C
Class K
Class D
Class B
Active Fire Protection
Passive fire protection
Active Fire Protection Vs Passive Fire Protection
Methods that require a certain amount of motion and response in order to react to put out the $ re by
locating smoke, % ames or heat, eg. Smoke & Heat extraction systems, Sprinkler systems, Fire extinguisher systems,
Gaseous clean agents, Fire$ ghting foam.
Methods that contain, minimize the impact, or slow the spread of the $ re. Contrary to active $ re
protection the coating system becomes an integral element of structural $ re protection and $ re safety in buildings
within a speci $ ed $ re compartment as well as ensuring that the load bearing capacity of the $ re exposed structure
is not reaching a critical level, the passive type does not need a response before reacting to the $ re eg. Intumescent
coatings, Retardant coatings, Resistive coatings, Ablative coatings.
: monarchindia.net : [email protected] : +(91)-9600992069
DEALERSHIP ENQUIRIES SOLICITED - Excellent Returns Assured
TYPICAL PROPERTIES
Follow us on :
Base Type
Color
Appearance
Mix Ratio By Weight
Solids By Weight
Density
Voc Content
Viscosity
Pot Life
Ph Value
Functional Cure Time
Maximum Application
Temp
Compressive Strength
Flame Spread Index
@ Class A
Smoke Develop Index
@ Class A
Limiting Oxygen Index
@ Class A
Expansion Times@
Original Thickness
Accelerated Weathering
Test @ 1000 Hrs
Abrasion Resistance
Fire Survival Test
Flammablity
Dielectric Strength
Bond Strength
Fire Resistant Test
Hardness
Flash Point
Chemical Resistance
Toxicity
Consumption
~
ASTM D 1544
ASTM D 1544
~
ASTM D 2369
ASTM D 1475
ASTM D 6886
ASTM D 891
IS 101
ASTM D 1293
ASTM D 5895
VISUAL
ASTM D 695
ASTM E 84
ASTM 2843
ASTM D 2863
ASTM E 119
ASTM D 4799
ASTM D1044-90
IEC 331
ASTM E 84 /
IEC 383
ASTM D 149
ASTM D 4541 /
ASTM E 736
BS 476 Part 20.
IEC 331
ASTM D 2240
ASTM E 56
ASTM C 267
~
~
~
~
~
grams
%
gm/cc
%
Cps
min
~
Hrs
°C
N/mm2
~
~
~
~
~
mg/
1000 cycles
min /1.1kv
/ 750° C
~
KV/ mm
N/mm2
min
Shore D
°C
%
~
Sq.m/Kg
/thickness
/No.of.coat
Epoxy Base
Grey
Low Viscous
Liquid
3.7( R):1 (H)
75
1.75
25
800
35
6
8
35
N/A
N/A
N/A
N/A
N/A
Passes
200
N/A
N/A
5
3.5
N/A
85
30
Excellent
Toxic
21 Sq.m/
4 kgs / @ DFT
0.125 mm
Acrylate Base
Custom Colors
High Viscous
Liquid
Single
60
1.25
35
2500
50
7.5
10
35
8.5
10
5
55
20
Passes
210
N/A
Passes
(Class B1)
N/A
2.6
F30, 60,
90,120
65
28
Excellent
Toxic
F 30 - 8 Sq.m
/ 5 kgs @ DFT
0.320 mm
Acrylate Base
Custom Colors
Low Viscous
Liquid
Single
50
1.1
45
1000
55
7
8
35
8.5
12
7
60
15
Passes
230
N/A
Passes
(Class B1 )
N/A
2.6
F30, 60,
90,120
62
28
Excellent
Toxic
F 30 - 15 Sq.m
/ 5 kgs @ DFT
0.180 mm
Water Base
Acrylic
Custom Colors
High Viscous
Liquid
Single
70
1.33
30
6000
45
8
24
38
9
10
1
70
50
Passes
205
20
Passes
(Class B1)
3 ( Kv / 5 min)
2.4
F 30
65
Nil
Good
Non Toxic
Single Cable
1.75 Sq.m/5 Kgs
@ DFT 1.5 mm
Water Base
Acrylic
Custom Colors
Low Viscous
Liquid
Single
65
1.25
35
3500
50
7
24
40
7.4
8
0
70
N/A
Passes
215
N/A
Passes
(Class B1)
N/A
2.4
F 20
82
Nil
Good
Non Toxic
10 Sq.m/ 5 Kg
@ DFT
0.250 mm
Epoxy Base
Custom Colors
High Viscous
Liquid
4 (R) : 1 (H)
100
1.25
Nil
3000
30
7
8
38
8
6
0
60
10
Passes
190
N/A
Passes
(Class B1)
25
5.2
F 30
84
28
Excellent
Non Toxic
5 Sq.m /5 kgs
@ DFT 1 mm
Cementitious
Grey
Free Flowing
Powder
W/P- 0.25
N/A
0.83
N/A
Slurry
35
12
24
35
5
10
2
75
0.5
Passes
400
N/A
Passes
(Class B1)
N/A
2.9
F 120
75
Nil
Fair
Non Toxic
F-120(2 Hour) -
150 Kg/Sq.m @
DFT 100 mm T
Chlorinated
Rubber base
Clear Transparent
High Viscous
Liquid
Single
50
1.34
45
1500
35
6.5
5
38
8.7
4
0
65
N/A
Passes
200
N/A
Passes
(ClassB1)
N/A
2.7
F20
64
28
Fair
Toxic
4.4 sq.m / 1 kg
/coat / 0.100 mm
Properties Standard UnitFlameGuard
ZP - Primer
FlameGuardSSP - Base Coat
FlameGuardSSP - Top Coat
FlameGuard
CP
FlameGuard
CC
FlameGuard
FRP
FlameGuard
EFM
FlameGuard
EIC
Clientele List
Structural
Steel ProtectionCable
Prote
ction
Wood
Prote
ction
Concrete
Wall P
rote
ction
Fire
Compartm
entatio
n
Hydro C
arbon &
Jet F
ire P
rote
ction