19
Contents Subject Detail Page General Construction G1.02 Parex Standard System components .3 G2.01 Insulation board application .......3 G3.01 Preliminary mesh application ...... 4 G4.01 Inside corner ....................4 G5.01 Outside corner ...................4 Expansion Joints E1.01 Track expansion joint .............5 E2.01 Backwrapped expansion joint ......5 E3.01 Building isolation joint ............5 E4.01 Dissimilar substrates ..............6 E5.01 Inside Corner at dissimilar substrates .6 E6.01 Wood framed sill .................7 E7.01 Wood framed floor line ...........7 Terminations T1.01 Termination above pavement .......8 T2.01 Termination above grade ..........8 T3.01 Base coat below grade ............9 T6.01 Termination at balcony deck .......9 Windows W1.01 Backwrapped jamb .............10 W2.01 Seal tape termination at flush / projecting jamb ...............10 W3.01 Insulated jamb return ...........10 W4.01 Uninsulated jamb return .........11 W5.01 Head with vented track 363 ......11 W6.01 Insulated head return ...........11 W7.02 Uninsulated head return .........12 W8.03 Rough sill edge wrapped prior to flashing ........12 W8.04 Backwrapped termination at sill . . .12 Roof Line R1.03 Parapet ........................13 R1.04 Parapet coated prior to flashing . . .13 R2.01 High wall at low roof ............14 R3.01 Gravel stop .....................14 R4.01 Insulated soffit ..................15 R5.03 Termination at soffit .............15 R6.02 Intersection of roof cornice at standard system wall ..........16 R6.02B Intersection of roof cornice at standard system wall .........16 Aesthetic Features A1.02 Aesthetic groove / reveal .........17 A2.01 Small aesthetic band / protection . .17 Penetrations P1.01 Fixture attachment ..............18 P2.02 Scupper ........................18 P3.01 Removable appliance ............18 The drawings, and any related notes, or text contained thereon are based upon typical requirements of Parex, Incorporated exterior insulation and finish systems and are published strictly as a guide for architectural and construction industry professionals to illustrate typical or general design conditions. These details are not to be used by themselves, and do not constitute design instructions for PB EIFS application. These details must be used in conjunction with Parex, Incorporated current product specifications, product data sheets, and application instructions. Any details shown are strictly for the purpose of illustrating typical PB EIFS design applications. Any other materials shown in any details are incidental to the details, and are included only for clarity of the PB EIFS system detail. Please consult with the manufacturers and/or suppliers of any separate materials for their product specifications and applications instructions. Where site or design conditions not shown in these details are present, or any unusual design is involved, please consult with Parex, Incorporated technical department for assistance. PAREX, INCORPORATED DOES NOT WARRANT THE FITNESS OF SUITABILITY OF THESE DETAILS FOR CONSTRUCTION, OR ASSUME ANY LIABILITY FOR USE OF THESE DETAILS. IT IS THE SOLE RESPONSIBILITY OF ANY ARCHITECTURAL OR CONSTRUCTION INDUSTRY PROFESSIONAL TO APPLY THEIR PROFESSIONAL KNOWLEDGE IN UTILIZING THE INFORMATION CONTAINED IN THESE DETAILS. PB EIF System Details CSI SECTION 07 24 00

PB EIF System Details - External Wall InsulationPAREX VENTED TRACK 363 G1.02 PAREX STANDARD SYSTEM COMPONENTS PB EIF System Details SEE ALSO INSIDE CORNER DETAIL G4.01 BACKWRAP AT

  • Upload
    others

  • View
    2

  • Download
    0

Embed Size (px)

Citation preview

Page 1: PB EIF System Details - External Wall InsulationPAREX VENTED TRACK 363 G1.02 PAREX STANDARD SYSTEM COMPONENTS PB EIF System Details SEE ALSO INSIDE CORNER DETAIL G4.01 BACKWRAP AT

ContentsSubject Detail Page

General Construction G1.02 Parex Standard System components .3

G2.01 Insulation board application . . . . . . .3

G3.01 Preliminary mesh application . . . . . . 4

G4.01 Inside corner . . . . . . . . . . . . . . . . . . . .4

G5.01 Outside corner . . . . . . . . . . . . . . . . . . .4

Expansion Joints E1.01 Track expansion joint . . . . . . . . . . . . .5

E2.01 Backwrapped expansion joint . . . . . .5

E3.01 Building isolation joint . . . . . . . . . . . .5

E4.01 Dissimilar substrates . . . . . . . . . . . . . .6

E5.01 Inside Corner at dissimilar substrates .6

E6.01 Wood framed sill . . . . . . . . . . . . . . . . .7

E7.01 Wood framed floor line . . . . . . . . . . .7

Terminations T1.01 Termination above pavement . . . . . . .8

T2.01 Termination above grade . . . . . . . . . .8

T3.01 Base coat below grade . . . . . . . . . . . .9

T6.01 Termination at balcony deck . . . . . . .9

Windows W1.01 Backwrapped jamb . . . . . . . . . . . . .10

W2.01 Seal tape termination at flush

/ projecting jamb . . . . . . . . . . . . . . .10

W3.01 Insulated jamb return . . . . . . . . . . .10

W4.01 Uninsulated jamb return . . . . . . . . .11

W5.01 Head with vented track 363 . . . . . .11

W6.01 Insulated head return . . . . . . . . . . .11

W7.02 Uninsulated head return . . . . . . . . .12

W8.03 Rough sill edge

wrapped prior to flashing . . . . . . . .12

W8.04 Backwrapped termination at sill . . .12

Roof Line R1.03 Parapet . . . . . . . . . . . . . . . . . . . . . . . .13

R1.04 Parapet coated prior to flashing . . .13

R2.01 High wall at low roof . . . . . . . . . . . .14

R3.01 Gravel stop . . . . . . . . . . . . . . . . . . . . .14

R4.01 Insulated soffit . . . . . . . . . . . . . . . . . .15

R5.03 Termination at soffit . . . . . . . . . . . . .15

R6.02 Intersection of roof cornice

at standard system wall . . . . . . . . . .16

R6.02B Intersection of roof cornice

at standard system wall . . . . . . . . .16

Aesthetic Features A1.02 Aesthetic groove / reveal . . . . . . . . .17

A2.01 Small aesthetic band / protection . .17

Penetrations P1.01 Fixture attachment . . . . . . . . . . . . . .18

P2.02 Scupper . . . . . . . . . . . . . . . . . . . . . . . .18

P3.01 Removable appliance . . . . . . . . . . . .18

The drawings, and any related notes,or text contained thereon are basedupon typical requirements of Parex,Incorporated exterior insulation andfinish systems and are published strictlyas a guide for architectural andconstruction industry professionals toillustrate typical or general designconditions.

These details are not to be used bythemselves, and do not constitute designinstructions for PB EIFS application.These details must be used in conjunctionwith Parex, Incorporated current productspecifications, product data sheets, andapplication instructions.

Any details shown are strictly for thepurpose of illustrating typical PB EIFSdesign applications. Any other materialsshown in any details are incidental tothe details, and are included only forclarity of the PB EIFS system detail.Please consult with the manufacturersand/or suppliers of any separate materialsfor their product specifications andapplications instructions.

Where site or design conditions notshown in these details are present, orany unusual design is involved, pleaseconsult with Parex, Incorporated technicaldepartment for assistance.

PAREX, INCORPORATED DOES NOTWARRANT THE FITNESS OF SUITABILITYOF THESE DETAILS FOR CONSTRUCTION,OR ASSUME ANY LIABILITY FOR USE OFTHESE DETAILS. IT IS THE SOLERESPONSIBILITY OF ANY ARCHITECTURALOR CONSTRUCTION INDUSTRYPROFESSIONAL TO APPLY THEIRPROFESSIONAL KNOWLEDGE INUTILIZING THE INFORMATIONCONTAINED IN THESE DETAILS.

PB EIF System DetailsCSI SECTION 07 24 00

Page 2: PB EIF System Details - External Wall InsulationPAREX VENTED TRACK 363 G1.02 PAREX STANDARD SYSTEM COMPONENTS PB EIF System Details SEE ALSO INSIDE CORNER DETAIL G4.01 BACKWRAP AT

A. FIRST COURSE OF EPS IS HALFWIDTH TO ALLOW FOR OFFSET OFHORIZONTAL JOINTS OF EPSINSULATION BOARD ANDSHEATHING BOARD

B. VERTICAL OFFSET OF EPS INSULATIONBOARD AND SHEATHING BOARD JOINTS SHOULD TYPICALLY BE NO LESS THAN 12”

- APPLY BOARDS OVER DRY SUBSTRATES IN A RUNNINGBOND PATTERN TYPICALLY LONG EDGE HORIZONTALLY.STAGGER VERTICAL JOINTS IN SUCCESSIVE COURSES.

- INTERLOCK ENDS AT INSIDE AND OUTSIDE OF CORNERS

- ABUT BOARDS TIGHTLY AT JOINTS WITHIN AND BETWEENEACH COURSE TO PRODUCE A FLUSH, CONTINUOUSLY EVENSURFACE WITHOUT GAPS. FILL ANY GAPS LARGER THAN 3/32”WITH INSULATION BOARD SLIVERS

- ALLOW THE ADHESIVE TO FORM A POSITIVE BOND, AMINIMUM OF 24 HOURS, OR LONGER AS REQUIRED BYCONDITIONS, SHALL ELAPSE PRIOR TO THE RASPING OFTHE INSULATION BOARD.

- LEVEL ANY IRREGULARITIES IN THE SURFACE OF THEINSULATION BOARD.

A = 12”B = 8” Min.

PAREX TRACK 363 OR BACKWRAPAS IN T2.01

SHEATHING SUBSTRATE (HIDDEN LINES INDICATE SHEATHING LOCATION

UNDER EPS INSULATION BOARD)

FOUNDATION

G2.01 INSULATION BOARD APPLICATION

(SHEATHED SUBSTRATES)

A

B

FRAMING

SUBSTRATE

PAREX ADHESIVE 121

EXPANDED POLYSTYRENE ASTM C-578 TYPE IINSULATION BOARD

PAREX REINFORCING MESH EMBEDDEDIN PAREX BASE COAT

PAREX BASE COAT

PAREX FINISH

PAREX VENTED TRACK 363

G1.02 PAREX STANDARD SYSTEM COMPONENTS

PB EIF System Details

Page 3: PB EIF System Details - External Wall InsulationPAREX VENTED TRACK 363 G1.02 PAREX STANDARD SYSTEM COMPONENTS PB EIF System Details SEE ALSO INSIDE CORNER DETAIL G4.01 BACKWRAP AT

SEE ALSO INSIDE CORNERDETAIL G4.01

BACKWRAP AT HEAD ORUSE PAREX VENTEDTRACK 363 AS APPLICABLE.SEE ALSO DETAILS W5.01- W7.02

INTERLOCKCORNERS OF EPS

SEE ALSOOUTSIDE CORNERDETAIL G5.01

NOTE EPS BOARD JOINTSDO NOT ALIGN WITHCORNERS OF OPENINGS

9” X 12” (23 X 30 cm) SHORTDETAIL MESH 356 EMBEDDEDDIAGONALLY IN BASE COATAT CORNERS

BACKWRAP OR USE PAREXTRACK SEE ALSO DETAILST101 AND T201

G3.01 PRELIMINARY MESH APPLICATION

PAREX REINFORCING MESHDOUBLE WRAPPED ANDEMBEDDED IN BASE COAT

PAREX FINISH

EPS

PAREX ADHESIVE

SUBSTRATE

G4.01 INSIDE CORNER

SUBSTRATE

PAREX ADHESIVE

EPS

PAREX REINFORCING MESHDOUBLE WRAPPED ANDEMBEDDED IN BASE COAT

PAREX FINISH

G5.01 OUTSIDE CORNER

Page 4: PB EIF System Details - External Wall InsulationPAREX VENTED TRACK 363 G1.02 PAREX STANDARD SYSTEM COMPONENTS PB EIF System Details SEE ALSO INSIDE CORNER DETAIL G4.01 BACKWRAP AT

PAREX VENTEDTRACK 363 FASTENEDTO SUBSTRATE

E.P.S.

PAREX REIFORCINGMESH EMBEDDED INBASE COAT. NOTEOVERLAP ONTO TRACK

PAREX BASE COAT

PAREX FINISH

CLOSED CELL POLYETHYLENEBACK AND ELASTOMERICSEALANT

3/4” (19 mm)MIN.

(AXONOMETRIC PICTORIAL)

E1.01 TRACK EXPANSION JOINT

MESH AT EPS BOARD EDGESFULLY EMBEDDED AND COVEREDWITH PAREX BASE COAT

PAREX SHORT DETAIL MESH356 BACKWRAPPED

MESH OVERLAPAT DETAIL MESH. 2 1/2” (63 mm) MIN.

EPS

PAREX BASE COAT

PAREX FINISH

CLOSED CELL POLYETHYLENEBACKER AND ELASTOMERICSEALANT, WITH SEALANTMANUFACTURER’S RECOMMENDEDPRIMER.

3/4” (19 mm) MIN.

(AXONOMETRIC PITORIAL)

2 1/2” (63 mm) MIN.

E2.01 BACKWRAPPED EXPANSION JOINT

E3.01 BUILDING ISOLATION JOINT

PAREX ADHESIVE

E.P.S.

PAREX BASE COATWITH REINFORCING

MESH EMBEDDED

PAREX FINISH

SEE DETAILS E1.01AND E2.01 FOR

EXPANSION JOINT

PB EIF System Details

Page 5: PB EIF System Details - External Wall InsulationPAREX VENTED TRACK 363 G1.02 PAREX STANDARD SYSTEM COMPONENTS PB EIF System Details SEE ALSO INSIDE CORNER DETAIL G4.01 BACKWRAP AT

E5.01 INSIDE CORNER AT DISSIMILAR SUBSTRATES

PAREX FINISH

PAREX BASE COAT WITHREINFORCING MESH EMBEDDED

E.P.S.

PAREX ADHESIVE

PAREX SHORT DETAIL MESH BACKWRAPPED ANDEMBEDDED IN BASE COAT OR USE PAREX TRACK

CLOSED CELL POLYETHYLENE BACKER ANDELASTOMERIC SEALANT, WITH SEALANTMANUFACTURER’S RECOMMENDED PRIMER.JOINT WIDTH MINIMUM 3/4” (19 mm).

PAREX ADHESIVE

E.P.S.

PAREX BASE COATWITH REINFORCING

MESH EMBEDDED

PAREX FINISH

SEE DETAILS E1.01AND E2.01 FOREXPANSION JOINT

E4.01 DISSIMILAR SUBSTRATES

Page 6: PB EIF System Details - External Wall InsulationPAREX VENTED TRACK 363 G1.02 PAREX STANDARD SYSTEM COMPONENTS PB EIF System Details SEE ALSO INSIDE CORNER DETAIL G4.01 BACKWRAP AT

WOOD FRAMING

SHEATHING

PAREX ADHESIVE

PAREX FINISH

WOOD SILL

SEE DETAIL E1.01 OR E2.01FOR EXPANSION JOINT

FOUNDATION WALL

PAREX BASE COAT WITHREINFORCING MESH EMBEDDED

E.P.S.

E6.01 WOOD FRAMED SILL (NON-RESIDENTIAL)

E7.01 WOOD FRAMED FLOOR LINE (NON-RESIDENTIAL)

WOOD FRAMING

PLYWOOD SHEATHING

ADHESIVELY ATTACHED EPS

PAREX BASE COATWITH MESH EMBEDDED

PAREX FINISH

CLOSED CELL POLYETHYLENEBACKER AND ELASTOMERICSEALANT

3/4” (19 mm) MIN.

PAREX TRACK 363

SOLE PLATE

SUBFLOOR

RIM JOIST

PB EIF System Details

Page 7: PB EIF System Details - External Wall InsulationPAREX VENTED TRACK 363 G1.02 PAREX STANDARD SYSTEM COMPONENTS PB EIF System Details SEE ALSO INSIDE CORNER DETAIL G4.01 BACKWRAP AT

SUBSTRATE

PAREX ADHESIVE

EXPANDED POLYSTYRENE (EPS)

RECOMMENDED PAREX HIGH IMPACTMESH 358.14 EMBEDDED IN PAREXBASE COAT

PAREX MESH EMBEDDEDIN PAREX BASE COAT

PAREX FINISH

PAREX TRACK 363 OR BACKWRAPAS IN T2.01

FOUNDATION

PAVEMENT

T1.01 TERMINATION ABOVE PAVEMENT

2” (5cm) MINIMUM

SUBSTRATE

PAREX ADHESIVE

EXPANDED POLYSTYRENE (EPS)

RECOMMENDED PAREX HIGH IMPACT MESH358.14 EMBEDDED IN PAREX BASE COAT

PAREX MESH EMBEDDEDIN BASE COAT

PAREX FINISH

PAREX SHORT DETAIL MESH 356 BACKWRAPPEDAND EMBEDDED IN BASE COAT OR USE TRACK

AS IN T1.01

T2.01 TERMINATION ABOVE GRADE

6” (15 cm) MIN.TO GRADE

FOUNDATION

Page 8: PB EIF System Details - External Wall InsulationPAREX VENTED TRACK 363 G1.02 PAREX STANDARD SYSTEM COMPONENTS PB EIF System Details SEE ALSO INSIDE CORNER DETAIL G4.01 BACKWRAP AT

FOUNDATION

SUBSTRATE

PAREX ADHESIVE

EXPANDED POLYSTYRENE (EPS)

RECOMMENDED PAREX HIGH IMPACTMESH 358.14 EMBEDDED IN PAREX

BASE COAT

PAREX MESH EMBEDDEDIN BASE COAT

PAREX FINISH

T3.01 BASE COAT BELOW GRADE

6” (15cm) MIN. TO GRADE

NOTE: APPLICATIONS DIRECTLYAPPLIED TO CONCRETE SHALLBE BASE COAT 121

T6.01 TERMINATION AT BALCONY DECK

SUBSTRATE

PAREX ADHESIVEEPS

PAREX BASE COAT WITHREINFORCING MESH

EMBEDDED

PAREX FINISH

PAREX VENTEDTRACK 363

ELASTOMERIC SEALANT

PITCH FOR POSITIVE DRAINAGE

BALCONY DECK

COMPRESSEDFOAM TAPE

PB EIF System Details

Page 9: PB EIF System Details - External Wall InsulationPAREX VENTED TRACK 363 G1.02 PAREX STANDARD SYSTEM COMPONENTS PB EIF System Details SEE ALSO INSIDE CORNER DETAIL G4.01 BACKWRAP AT

JAMB

W1.01 BACKWRAPPED JAMB

CLOSED CELL POLYETHYLENE BACKER ANDELASTOMERIC SEALANT, WITH SEALANTMANUFACTURER’S RECOMMENDED PRIMER

PAREX SHORT DETAIL MESH 356 BACKWRAPPEDAND EMBEDDED IN BASE COAT

PAREX FINISHPAREX BASE COAT WITHREINFORCING MESH EMBEDDED

EPS

SUBSTRATE

PAREX ADHESIVE

W2.01 COMPRESSED FOAM TAPE TERMINATION AT FLUSH / PROJECTING JAMB

JAMB

SUBSTRATE

PAREX ADHESIVE

EPS

COMPRESSED FOAM TAPE

PAREX BASE COAT WITHREINFORCING MESH EMBEDDED

PAREX FINISH

W3.01 INSULATED JAMB RETURN

JAMB

DOUBLE WRAPPED MESH EMBEDDEDIN BASE COAT

PAREX FINISH

PAREX BASE COAT WITHREINFORCING MESH EMBEDDED

EPS

PAREX ADHESIVE

SUBSTRATE

CLOSED CELL POLYETHYLENE BACKERAND ELASTOMERIC SEALANT WITH SEALANTMANUFACTURER’S RECOMMENDED PRIMER

Page 10: PB EIF System Details - External Wall InsulationPAREX VENTED TRACK 363 G1.02 PAREX STANDARD SYSTEM COMPONENTS PB EIF System Details SEE ALSO INSIDE CORNER DETAIL G4.01 BACKWRAP AT

W4.01 UNINSULATED JAMB RETURN

JAMB

CLOSED CELL POLYETHYLENE BACKERAND ELASTOMERIC SEALANT WITH SEALANTMANUFACTURER’S RECOMMENDED PRIMER

DOUBLE WRAPPED MESH EMBEDDEDIN BASE COAT

PAREX FINISH

MASONRY SUBSTRATE

PAREX ADHESIVE PAREX BASE COAT WITHREINFORCING MESH EMBEDDED

EPS

W5.01 HEAD WITH VENTED TRACK 363

SUBSTRATE

PAREX ADHESIVE

EPS

PAREX BASE COAT WITHREINFORCING MESH EMBEDDED

PAREX FINISH

PAREX VENTED TRACK 363

CLOSED CELL POLYETHYLENEBACKER AND ELASTOMERIC SEALANT

HEAD

W6.01 INSULATED HEAD RETURN

SUBSTRATE

PAREX ADHESIVE

EPS

PAREX BASE COAT WITHREINFORCING MESH EMBEDDED

PAREX FINISH

DOUBLE WRAPPED MESHEMBEDDED IN BASE COAT

DRIP GROOVE

HEAD

CLOSED CELL POLYETHYLENE BACKERAND ELASTOMERIC SEALANT WITH SEALANTMANUFACTURER’S RECOMMENDED PRIMER

3/4” (19 mm) MIN.

PB EIF System Details

Page 11: PB EIF System Details - External Wall InsulationPAREX VENTED TRACK 363 G1.02 PAREX STANDARD SYSTEM COMPONENTS PB EIF System Details SEE ALSO INSIDE CORNER DETAIL G4.01 BACKWRAP AT

W7.02 UNINSULATED HEAD RETURN

MASONRY SUBSTRATE

PAREX ADHESIVE

EPS

PAREX BASE COAT WITHREINFORCING MESH EMBEDDED

PAREX FINISH

DRIP EDGE

PAREX SHORT DETAIL MESHBACKWRAPPED AND EMBEDDEDIN BASE COAT

3/4” (19 mm) MAX.

PAREX BASE COAT& PAREX FINISH

CLOSED CELL POLYETHYLENE BACKERAND ELASTOMERIC SEALANT WITH SEALANTMANUFACTURER’S RECOMMENDED PRIMER

HEAD

W8.03 ROUGH SILL EDGE WRAPPED PRIOR TO FLASHING

SILL

JAMB RETURN BEYOND

MESH EMBEDDED IN BASE COATCONTINUOUS THROUGH SILL / JAMBRETURN INTERFACE

FLASHING

1” (25 mm) MIN.

ELASTOMERIC SEALANT

PAREX BASE COAT WITH PAREXREINFORCING MESH EMBEDDEDLAPPING OVER FRAMING

PAREX ADHESIVE

EPS

PAREX BASE COAT WITHREINFORCING MESH EMBEDDED

PAREX FINISH

W8.04 BACKWRAPPED TERMINATION AT SILL

SILL

JAMB RETURN BEYOND

MESH EMBEDDED IN BASE COATCONTINUOUS THROUGH SILL /JAMBRETURN INTERFACE

FLASHING

1” (25 mm) MIN.

PAREX SHORT DETAIL MESH 356BACKWRAPPED AND EMBEDDEDIN BASE COAT

ELASTOMERIC SEALANT

PAREX ADHESIVE

EPS

PAREX BASE COAT WITHREINFORCING MESH EMBEDDED

PAREX FINISH

Page 12: PB EIF System Details - External Wall InsulationPAREX VENTED TRACK 363 G1.02 PAREX STANDARD SYSTEM COMPONENTS PB EIF System Details SEE ALSO INSIDE CORNER DETAIL G4.01 BACKWRAP AT

R1.03 PARAPET

1 1/2” (38 mm)MINIMUM

PAREX SHORT DETAIL MESH 356BACKWRAPPED & EMBEDDED inBASE COAT

SUBSTRATE

ELASTOMERIC SEALANT

PAREX ADHESIVE

EPS

PAREX BASE COAT WITHREINFORCING MESH EMBEDDED

PAREX FINISH

METAL COPING / FLASHING

R1.04 PARAPET COATED PRIOR TO FLASHING

1 1/2” (38 mm) MINIMUM

METAL COPING / FLASHING

PAREX MESH REINFORCED BASECOAT WRAPPING EPS ANDOVERLAPPING SUBSTRATE

SUBSTRATE

ELASTOMERIC SEALANT

PAREX ADHESIVE

EPSPAREX BASE COAT WITHREINFORCING MESH EMBEDDED

PAREX FINISH

PB EIF System Details

Page 13: PB EIF System Details - External Wall InsulationPAREX VENTED TRACK 363 G1.02 PAREX STANDARD SYSTEM COMPONENTS PB EIF System Details SEE ALSO INSIDE CORNER DETAIL G4.01 BACKWRAP AT

R2.01 HIGH WALL AT LOW ROOF

SUBSTRATE

PAREX ADHESIVE

EPS

PAREX BASE COATWITH REINFORCING MESH

EMBEDDED4” (10 cm) MIN.OVERLAP ONTO

FLASHING PAREX FINISH

PAREX TRACK 363OR BACKWRAP WITHSHORT DETAIL MESH 356

8” (20 cm)MINIMUM

FRAMING

BASE FLASHING

R3.01 GRAVEL STOP

GRAVEL STOP

BACKWRAPPED SHORT DETAIL MESHEMBEDDED IN BASE COAT

1 1/2” (38 mm)MIN.

ELASTOMERIC SEALANT

SUBSTRATE

PAREX ADHESIVE

EPS

PAREX BASE COAT WITHREINFORCING MESHEMBEDDED

PAREX FINISH

Page 14: PB EIF System Details - External Wall InsulationPAREX VENTED TRACK 363 G1.02 PAREX STANDARD SYSTEM COMPONENTS PB EIF System Details SEE ALSO INSIDE CORNER DETAIL G4.01 BACKWRAP AT

R4.01 INSULATED SOFFIT

SUBSTRATE

PAREX ADHESIVE

EPS

PAREX BASE COAT WITHREINFORCING MESH EMBEDDED

PAREX FINISH

3/4” (19 mm) MIN.EPS THICKNESSSEE DETAIL A1.02FOR GROOVE

OUTSIDE CORNERSEE DETAIL G5.01

INSDIE CORNERSEE DETAIL G4.01

3” (7.6 cm) MAX.

NOTE: FOR UNCONDITIONEDAIR SPACE, PROVIDE VENTILATION AS REQUIRED

R5.03 TERMINATION AT SOFFIT

CLOSED CELL BACKER ANDELASTOMERIC SEALANT, WITHSEALANT MANUFACTURER’SRECOMMENDED PRIMER

PAREX SHORT DETAIL MESH356 BACKWRAPPED AND EMBEDDED IN BASE COAT

PAREX TRACK 363

SUBSTRATE

3/4” (19 mm) MAX.

BACKWRAPPED PAREX SHORTDETAIL MESH 356 EMBEDDED INBASE COAT

PAREX DIRECT SOFFIT APPLICATION

NOTE: FOR UNCONDITIONEDAIR SPACE, PROVIDEVENTILATION AS REQUIRED

COMPRESSED FOAMTAPE

PAREX ADHESIVE

EPSPAREX BASE COAT WITH

REINFORCING MESH EMBEDDED

PAREX FINISH

ALTERNATES

PB EIF System Details

Page 15: PB EIF System Details - External Wall InsulationPAREX VENTED TRACK 363 G1.02 PAREX STANDARD SYSTEM COMPONENTS PB EIF System Details SEE ALSO INSIDE CORNER DETAIL G4.01 BACKWRAP AT

R6.02 INTERSECTION OF ROOF CORNICE AT STANDARD SYSTEM WALL

5” (13 cm)MIN.

5” (13 cm)MIN.

8” (20 cm)

110°

WATER TIGHTSEAMS

KICK-OUT FLASHINGCONSTRUCTION

KICK-OUT SHOULD EXTEND 3” (7.6 cm) MINBEYOND THE FACE OF THE SYSTEM

BACKWRAP AROUND KICK-OUTWITH MESH REINFORCED BASECOAT. SEAL WITH CLOSED CELLBACK ROD & ELASTOMERIC SEALANT.

FASCIA

PAREX STANDARDSYSTEM

CONTINUOUS STEP FLASHING SEE DETAIL R6.02B FOR MORE INFO.

UNDERLAYMENT

METAL DRIP EDGE

SEE DETAILS R5.03FOR RELATED INFO.

ROOF SHINGLES

SEE RELATED DETAIL R6.02BFOR TERMINATION OF STANDARDSYSTEM ABOVE ROOF

SUBSTRATE

PAREX ADHESIVE

EXPANDED POLYSTYRENE

PAREX MESH REINFORCEDBASE COAT

PAREX FINISH

PAREX TRACK 363

METAL STEP FLASHING

ROOF SHINGLE

UNDERLAYMENT

2” MIN.

4” MIN.

R6.02B INTERSECTION OF ROOF CORNICE AT STANDARD SYSTEM WALL

Page 16: PB EIF System Details - External Wall InsulationPAREX VENTED TRACK 363 G1.02 PAREX STANDARD SYSTEM COMPONENTS PB EIF System Details SEE ALSO INSIDE CORNER DETAIL G4.01 BACKWRAP AT

PAREX BASE COAT WITHREINFORCING MESH EMBEDDED.NOTE 2 1/2” (6.3 cm) MIN. OVER-LAP AT DETAIL MESH.

PAREX SHORT DETAIL MESH 356EMBEDDED IN BASE COAT

PITCH FORPOSITIVEDRAINAGE

PAREX FINISH

EPS

PAREX ADHESIVE

SUBSTRATE

A1.02 AESTHETIC GROOVE / REVEAL

PAREX FINISH

PAREX BASE COAT WITH REINFORCING MESH EMBEDDED NOTE: 2 1/2” (6.3 cm) MIN. OVERLAP AT DETAIL MESH.

PAREX DETAIL MESH EMBEDDED IN BASE COAT

PAREX ADHESIVE

EPS FEATURE

EPS

PAREX ADHESIVE

SUBSTRATE

A2.01 SMALL AESTHETIC BAND / PROJECTION

PB EIF System Details

Page 17: PB EIF System Details - External Wall InsulationPAREX VENTED TRACK 363 G1.02 PAREX STANDARD SYSTEM COMPONENTS PB EIF System Details SEE ALSO INSIDE CORNER DETAIL G4.01 BACKWRAP AT

P3.01 REMOVABLE APPLIANCE

SUBSTRATE

PAREX ADHESIVE

EPS

PAREX TRACK

REMOVABLE APPLIANCE

PAREX BASE COAT WITHREINFORCING MESH EMBEDDED

PAREX FINISH

P1.01 FIXTURE ATTACHMENT

FRAMING

SUBSTRATE

PAREX ADHESIVEEPS

BLOCKING

ELASTOMERIC SEALANT

CORROSION RESISTANT FASTENER

CORROSION RESISTANT WASHER

P.V.C. PIPE SLEEVE FILLED WITHELASTOMERIC SEALANT

FIXTURE

PAREX BASE COAT WITHREINFORCING MESH EMBEDDED

PAREX FINISH

P2.02 SCUPPER

SUBSTRATE

PAREX ADHESIVEEPS

PAREX BASE COAT WITHREINFORCING MESH EMBEDDED

BACKWRAPPED PAREX SHORTDETAIL MESH EMBEDDEDIN BASE COAT

PAREX FINISH

4” (10 cm) MIN.

SCUPPER

CLOSED CELL BACKER &ELASTOMERIC SEALANT, WITH

SEALANT MANUFACTURER’SRECOMMENDED PRIMER

Page 18: PB EIF System Details - External Wall InsulationPAREX VENTED TRACK 363 G1.02 PAREX STANDARD SYSTEM COMPONENTS PB EIF System Details SEE ALSO INSIDE CORNER DETAIL G4.01 BACKWRAP AT

PB EIF System Details

CSI SECTION 07 24 00

Corporate OfficeParexLaHabra4125 E. La Palma Avenue, Suite 250Anaheim, CA 92807(714) 778-2266

Sales OfficeParex1870 Stone Mountain-Lithonia RoadRedan, GA 30074(800) 537-2739

PlantsRiverside, CAFrench Camp, CAColorado Springs, COAlbuquerque, NMSan Antonio, TXWilkes Barre, PARedan, GA

www.parex.com© ParexLahabra July 2007 • PPBESD

Page 19: PB EIF System Details - External Wall InsulationPAREX VENTED TRACK 363 G1.02 PAREX STANDARD SYSTEM COMPONENTS PB EIF System Details SEE ALSO INSIDE CORNER DETAIL G4.01 BACKWRAP AT

Parex Assistance Request

Thank you for your interest. In an effort to keep you informed, we would like you to fill out this brief registration form.

Name:

Company:

Address:

City:

State: Zip: Country:

Phone:

e-mail:

Occupation:

Are you presently working on a project? Yes No

Type:

Size in Sq. Ft.: