Upload
others
View
1
Download
0
Embed Size (px)
Citation preview
Location Map N.T.S.
SITE
PEPPERTREE
ESTATES S/D
PRELIMINARY PLAT
(NOT TO BE RECORDED)
KNIGHT HOMES, INC.9497 Thornton Blvd.Jonesboro, GA 30236
Contact Person: Jay Knight
P: (770) 527-0323
PROJECT INFORMATION:
NOTES:
System installation should not occur under saturated soil conditions
Absorption fields should not be installed on concave slopes.
Surface drainage should be diverted away from absorption field lines.
Gutter downspouts should be discharged away from the vicinity of the on
site wastewater system.
Estimated percolation rates are based on full-sized system performance.
However, no guarantee is given or implied as to the performance of any
particular system installed.
PE
PP
ER
TR
EE
E
ST
AT
ES
PROFESSIONAL
No. 29411
D
E
R
ET
S
I
G
E
R
R
E
E
NI
G
E
N
DR
AW
N B
Y: G
PH
DA
TE
:S
CA
LE
:
LL 80
CO
WE
TA
C
OU
NT
Y
SH
EE
T:
PR
OJE
CT
:
DR
AW
IN
G N
O:
DE
SC
RIP
TIO
N:
DA
TE
:R
EV
.
PH
: (7
70
)-4
73
-9
57
6
ge
org
e@
pa
ra
mo
un
te
ng
in
ee
rin
g.co
m
11
E
. B
RO
AD
S
T.
NE
WN
AN
, G
A. 3
02
63
SHEET
6T
H D
IS
TR
IC
T
02-12-18
280201- P
EP
PE
RT
RE
E
GSWCC NO. 09374
AD
DR
ES
SE
D C
IT
Y/ H
CW
A C
OM
ME
NT
S05-24-18
1
RE
V. LA
YO
UT
/ A
DD
ED
A
CR
EA
GE
08-28-18
2
NO
S
CA
LE
1
CO
VE
R S
HE
ET
O1
C1
SOIL SUITABILITY LEGEND
A1Soils are typically suitable for conventional absorption field with proper design, installation and maintenance.
Soils consist of local alluvium or wash over wash over natural soils. Residual soil is suitable for conventional absorption field installation at
recommended trench depth. Storm water runoff must be diverted from this area if it is used for absorption field.
Soils are typically suitable for conventional absorption field with proper design, installation and maintenance. The Bt horizon shows some
evidence of slow percolation, subsoil is well drained. Trenches installed at the recommended depth should function effectively.
Soils are unsuitable for conventional absorption fields due to perched water table conditions. Soils are generally suitable for alternative
absorption fields with treatment system producing Class 1 effluent.
Soils are unsuitable for conventional absorption fields due to seasonal-high water table conditions. Soils are generally suitable for alternative
absorption fields with treatment system producing Class 1 effluent.
Soils are unsuitable for on-site wastewater disposal due to seasonal high water table.
Soils are located in a landscape position that renders them unsuitable for on-site wastewater disposal due to flooding and/ or storm water
drainage patterns.
Soils consist of a mixture of filled and cut soils. Further investigation of test pits dug with a backhoe should be conducted in this area to
determine the suitability of soils for septic system construction..
Soils contain somewhat shallow parent material and weathered rock. Hand auger borings have been advanced to a depth of 5 feet and
parent material is generally suitable for conventional absorption field installation. Estimated perc rate accounts for presence of seams of
weathered rock.
Soils show evidence of a somewhat restrictive layer in the upper part of the profile. Brief perching of water may cause problems for
absorption fields installed in the upper part of the soil profile. Soil below somewhat restrictive layer appear to be well drained with texture and
structure that should provide a suitable percolation rate. Conventional absorption field installed below restrictive layer should function
effectively. Environmental Health Department may require further inspection utilizing backhoe test pits prior to permitting.
Soils are typically suitable for conventional absorption field with proper design, installation and maintenance. Absorption trenches must be
installed at least 24 inches above seasonal high water table to function effectively. Seasonal high water table indicators were observed
between 54 and 60 inches. Installations deeper than 30 inches may require a treatment system producing Class 1 effluent.
C2
P1
A5
F4
F2
Estimated Perc Rate
(min/in)
Slope
Gradient
(percent)
Soil
Suit.
Code
Depth to Seasonal
High
Water Table (in)
Depth to
Bedrock
(in)
Soil Units
SOIL INTERPRETIVE DATA
Recommended
Trench
Depth (in)
>72
24-30
(PWT)
12 C12-10 Cataula II
>72 >72 30-48 A12-10 Cecil60
>72 36 18-24 C22-10 Hard Labor II75
>72 >72 36-48 A21-5
Wash Over
Cecil
60
>72 16-24 F46-15 Abell
75
----
Recommended
Hydraulic
Loading Rate
(gal/day/sq.ft.)
0.10
0.15
*INDICATES DEPTH TO TOP AND BOTTOM OF RESTRICTIVE LAYER THAT IS CAUSING BRIEF PERCHING OF WATER TABLE. SOIL APPEARS TO BE WELL
DRAINED BELOW RESTRICTIVE LAYER.
PWT = Perched Water Table
P14-8
Cecil
Wet Variant
54-60>72
24-30
>72
24-42*
(PWT)
54-72 O12-10 Cataula III70
----
----
----
----
------------
>72 24 12 C22-10 Hard Labor I90
0.10
>72 >72 ---- F42-6 Starr----
----
>72 >72 30-48 A12-12 Pacolet45
----
>72 >72 40-60 A52-10
Cecil
Variant
60----
A2
>72 >72 ---- F5C1-5 Udorthents----
----
>60 >60 N36-15 Bethlehem ----7024-36
F5C
N3
44,618 SF.1.02 AC.
45,751 SF.1.05 AC.
44,867 SF.1.03 AC.
44,739 SF.1.03 AC.
44,611 SF.1.02 AC.
44,484 SF.1.02 AC.
84,767 SF.1.95 AC.
48,424 SF.1.11 AC.
47,110 SF.1.08 AC.
47,310 SF.1.09 AC.
47,291 SF.1.09 AC.
N88°56'17"W
1331.64'
S14°23'13"W 1345.26'
S26°53'38"E149.96'
S27°40'35"E
260.38'
375' 130' 130' 130' 130' 132' 67' 75'
342'
343'
344'
345'
346'
343'
89'
364'
130'
315'
244'
357'
130' 130' 130' 130' 133'
222'
12'
42'
89'
100'
269'
106'
97'
PEPPERTREE DR. (50' R/W)
1234567
9
10
11
15
14
1
OPEN SPACE #1
0.57 Ac.
47,301 SF.1.09 AC.
70,057 SF.1.61 AC.
8
844.64'
377.00'
P
A
L
M
E
T
T
O
-
T
Y
R
O
N
E
R
D
.
(
5
0
'
R
/
W
)
PROP.DET. POND
12
13
OPEN SPACE #218.11 Ac.
16
17
18
19
20 21 22 2324 25
26
OPEN
SPA
CE #
30.
97 A
c.
110.00'
47,287 SF.1.09 AC.
85,387 SF.1.96 AC. 57,078 SF.
1.31 AC.
62,008 SF.1.42 AC.
130'130' 130' 130'
130' 130'130'130'
364'
364'
364'
364'
384'
399'
412'167'
96'
93'
214'
304'
45,795 SF.1.05 AC.
44,480 SF.1.02 AC.
53,742 SF.1.23 AC.
47,068 SF.1.08 AC.
48,624 SF.1.12 AC. 46,625 SF.
1.07 AC.
43,869 SF.1.01 AC.
43,680 SF.1.00 AC.
130'
130'
130'
130'
130'
39'
72'
130'
130'
130'
130'
239'
285'
14'
347'
337'
367'
403'
429'
326'
336'
336'
336'
318'
307'
305'
309' 134'
132'
130'
130'
172'
38'61'
16'
75'
12'
12'
46' 38'
41'
50' UNDISTURBED STREAM BUFFER
75' IMPERVIOUS SETBACKCREEK
N 03°31'44"E
999.13'
S26°35'09"E399.97'
6
1
2
3
4
5
8
7
10
9
125'
292'
177'46'
25' STATE WATERS BUFFER
43,680 SF.1.00 AC.
1
0
0
' F
t B
u
ffe
r
OWNER/DEVELOPER:
24 HOUR CONTACT
PRIMARY PERMITTEE
KNIGHT HOMES, INC.
JAY KNIGHT
9497 Thornton Rd.
Jonesboro, Ga. 30236
PH: 770-527-0323
BASED ON THE INFORMATION SHOWN ON THE FLOOD HAZARD BOUNDARY MAPS
FURNISHED BY THE DEPT. OF HUD THROUGH THE FEMA IT IS MY OPINION THAT THE
PROPERTY SHOWN HEREON IS OUTSIDE OF ANY SPECIAL FLOOD HAZARD AREA.
COMMUNITY PANEL #13077C 0160D DATED: FEBRUARY 6, 2013
8.60 AC.
OFF-SITE
DRAINAGE
2.63 AC.
OFF-SITE
DRAINAGE
4.62 AC.
OFF-SITE
DRAINAGE
PROJECT INFORMATION:
PE
PP
ER
TR
EE
E
ST
AT
ES
PROFESSIONAL
No. 29411
D
E
R
ET
S
I
G
E
R
R
E
E
NI
G
E
N
DR
AW
N B
Y: G
PH
DA
TE
:S
CA
LE
:
LL 80
CO
WE
TA
C
OU
NT
Y
SH
EE
T:
PR
OJE
CT
:
DR
AW
IN
G N
O:
DE
SC
RIP
TIO
N:
DA
TE
:R
EV
.
PH
: (7
70
)-4
73
-9
57
6
ge
org
e@
pa
ra
mo
un
te
ng
in
ee
rin
g.co
m
11
E
. B
RO
AD
S
T.
NE
WN
AN
, G
A. 3
02
63
SHEET
6T
H D
IS
TR
IC
T
02-12-18
280201- P
EP
PE
RT
RE
E
GSWCC NO. 09374
AD
DR
ES
SE
D C
IT
Y/ H
CW
A C
OM
ME
NT
S05-24-18
1
RE
V. LA
YO
UT
/ A
DD
ED
A
CR
EA
GE
08-28-18
2
1" =
6
0'
2
PR
EL
IM
IN
AR
Y P
LA
T
5
3
P
R
O
P
C
O
R
T
R
E
E
1
0
1
5
.9
9
5
0
IP
F
1
/2
" R
B
C
A
P
R
P
L
S
1
0
2
4
.7
7
5
1
IP
F
1
/2
" R
B
C
A
P
R
P
L
S
1
0
2
5
.4
5
5
2
IP
F
1
/2
" R
B
C
A
P
R
P
L
S
1
0
2
4
.9
3
5
4
IP
F
1
/2
" R
B
1
0
1
1
.2
7
1
D
E
L
1
0
3
0
.4
4
5
D
E
L
1
0
2
2
.0
1
6
D
E
L
1
0
2
6
.1
3
7
D
E
L
1
0
1
6
.2
1
8
D
E
L
1
0
1
6
.4
8
9
D
E
L
1
0
1
9
.0
1
1
0
D
E
L
1
0
1
0
.4
0
1
1
D
E
L
1
0
2
5
.8
2
5
0
IP
F
1
/2
" R
B
C
A
P
R
P
L
S
1
0
2
4
.7
7
5
1
IP
F
1
/2
" R
B
C
A
P
R
P
L
S
1
0
2
5
.4
5
5
2
IP
F
1
/2
" R
B
C
A
P
R
P
L
S
1
0
2
4
.9
3
5
3
P
R
O
P
C
O
R
T
R
E
E
1
0
1
5
.9
9
5
4IP
F
1
/2
" R
B
1
0
1
1
.2
7
1
0
0
E
P
1
0
2
6
.3
7
1
0
1
E
P
1
0
2
6
.4
3
1
0
2
E
P
1
0
2
6
.7
0
1
0
3
E
P
1
0
2
6
.5
1
1
0
4
W
V
1
0
2
3
.8
11
0
5
F
H
1
0
2
3
.5
6
1
0
6
E
P
1
0
2
6
.6
9
1
0
7
E
P
1
0
2
7
.0
0
1
0
8
E
P
1
0
2
7
.2
1
1
0
9
E
P
1
0
2
7
.1
0
1
1
0
P
P
1
0
2
4
.5
7
1
1
1
P
P
1
0
2
5
.1
4
1
1
2
E
P
1
0
2
7
.6
1
1
1
3
E
P
1
0
2
7
.6
3
1
1
4
E
P
1
0
2
8
.0
2
1
1
5
E
P
1
0
2
8
.2
6
1
1
6
E
P
1
0
2
8
.8
8
1
1
7
E
P
1
0
2
8
.7
4
1
1
8
E
P
1
0
2
9
.5
0
1
1
9
E
P
1
0
2
9
.7
6
1
2
0
T
P
E
D
1
0
2
7
.8
1
1
2
1
T
P
1
0
2
8
.3
4
1
2
2
P
P
1
0
2
9
.3
6
1
2
3
P
P
1
0
2
9
.0
9
1
2
4
E
P
1
0
3
0
.5
8
1
2
5
E
P
1
0
3
0
.2
4
1
2
6
E
P
1
0
3
1
.1
2
1
2
7
E
P
1
0
3
1
.6
4
1
2
8
E
P
1
0
3
2
.7
3
1
2
9
E
P
1
0
3
2
.3
7
1
3
0
E
P
1
0
3
3
.5
5
1
3
1
E
P
1
0
3
3
.6
9
1
3
2
P
P
1
0
3
3
.1
9
1
3
3
T
P
N
F
E
1
0
5
2
.0
2
1
3
4
P
/P
N
F
E
1
0
6
9
.1
2
N88°56'17"W
1331.64'
S14°23'13"W 1345.26'
S26°53'38"E149.96'
S27°40'35"E
260.38'
PEPPERTREE DR. (50' R/W)
1234567
9
10
11
15
14
1
OPEN SPACE #1
0.57 Ac.
8
844.64'
377.00'
P
A
L
M
E
T
T
O
-
T
Y
R
O
N
E
R
D
.
(
5
0
'
R
/
W
)
PROP.DET. POND
12
13
OPEN SPACE #218.11 Ac.
16
17
18
19
20 21 22 2324 25
26
OPEN
SPA
CE #
30.
97 A
c.
110.00'
N 03°31'44"E
999.13'
S26°35'09"E399.97'
6
1
2
3
4
5
8
7
10
9
A
1
A
2
A
3
A
4
A
5
A
6
A
7
A
8
A
9
A
1
0
A
1
1
A
1
A
2
A
3
A
4
A
5
A
6
A
7
A
8
A
9
A
1
0
A
1
1
C
E
C
IL
P
A
C
O
L
E
T
W
A
S
H
O
V
E
R
C
E
C
IL
C
E
C
IL
C
E
C
IL
P
A
C
O
L
E
T
CECIL
WET
VARIANT
C
A
T
A
U
L
A
II
C
A
T
A
U
L
A
II
H
A
R
D
L
A
B
O
R
I
HA
RD
L
AB
OR
II
P
A
C
O
L
E
T
A
B
E
L
L
A
B
E
L
L
A
B
E
L
L
H
A
R
D
L
A
B
O
R
I
I
P
A
C
O
L
E
T
P
A
C
O
L
E
T
C
E
C
IL
C
E
C
IL
C
E
C
I
L
W
E
T
V
A
R
I
A
N
T
C
E
C
IL
CA
TA
UL
A III
H
A
R
D
L
A
B
O
R
I
I
C
E
C
I
L
W
E
T
V
A
R
I
A
N
T
C
E
C
IL
V
A
R
IA
N
T
S
T
A
R
R
B
1
B
2
C
E
C
IL
B
3
B
5
B
6
B
7
1
0
0
' F
t B
u
ffe
r
B
4
B
8
Z
1
Z
2
Z
3
Z
4
Z
5
Z
6
Z
7
Z
8
Z
9
Z
1
0
Z
1
1
Z
1
2
Z
1
3
Z
1
4
Z
1
5
Z
1
6
Z
1
7
Z
1
8
Z
1
9
Z
2
0
Z
2
1
Z
2
2
Z
2
3
Z
2
4
Z
2
5
Z
2
6
Z
2
7
Z
2
8
Z
2
9
Z
3
0
Z
3
1
Z
3
2
Z
3
3
Z
3
4
Z
3
5
Z
3
6
Z
3
7
Z
3
8
Z
3
9
Z
4
0
Z
4
2
Z
4
2
Z
4
3
Z
4
4
Z
4
5
Z
4
6
Z
4
7
Z
4
8
Z
4
9
Z
5
0
Z
5
1
Z
5
2
Z
5
3
Z
5
4
Z
5
5
Z
5
6
Z
5
7
Z
5
8
Z
5
9
Z
6
0
Z
6
1
Z
6
2
Z
6
3
Z
6
4
Z
6
5
Z
6
6
Z
6
7
Z
6
8
Z
6
9
Z
7
0
Z
7
1
Z
7
2
Z
7
3
Z
7
4
Z
7
5
Z
7
6
Z
7
7
Z
7
8
Z
7
9
Z
8
0
Z
8
1
Z
8
2
Z
8
3
Z
8
4
Z
8
5
Z
8
6
Z
8
7
Z
8
8
Z
8
9Z
9
0
Z
9
1
Z
9
2
Z
9
3
Z
9
4
Z
9
5
Z
9
6
X
1
X
2
X
3
X
4
X
5X
6
X
7
X
8
X
9
X
1
0
X
1
1
X
1
2
X
1
3
X
1
4
X
1
5
X
1
6
X
1
7
X
1
8X
1
9
X
2
0
X
2
1
X
2
2
X
2
3
X
2
4
X
2
5
X
2
6
X
2
7
X
2
8
X
2
9
X
3
0
X
3
1
X
3
2
X
3
3
X
3
4
X
3
5
X
3
6
X
3
7
X
3
8
X
3
9
X
4
0
X
4
1
X
4
2
X
4
3
X
4
4
X
4
5
X
4
6
X
4
7
X
4
8
X
4
9
X
5
0
X
5
1
X
5
2
X
5
3
X
5
4
X
5
5
X
5
6
X
5
7
X
5
8
X
5
9
X
6
0
X
6
1
X
6
2
X
6
3
X
6
4
X
6
5
C
E
C
IL
W
E
T
V
A
R
IA
N
T
W
.O
.C
.
B
E
T
H
L
E
H
E
M
B
E
T
H
L
E
H
E
M
C
E
C
IL
C
E
C
IL
B
E
T
H
L
E
H
E
M
C
E
C
IL
C
E
C
IL
C
A
T
A
U
L
A
II
C
A
T
A
U
L
A
II
U
D
O
R
T
H
E
N
T
S
OWNER/DEVELOPER:
24 HOUR CONTACT
PRIMARY PERMITTEE
KNIGHT HOMES, INC.
JAY KNIGHT
9497 Thornton Rd.
Jonesboro, Ga. 30236
PH: 770-527-0323
Hand Auger Boring
MAP LEGEND
Soil Boundary
B1
Gully
PE
PP
ER
TR
EE
E
ST
AT
ES
PROFESSIONAL
No. 29411
D
E
R
ET
S
I
G
E
R
R
E
E
NI
G
E
N
DR
AW
N B
Y: G
PH
DA
TE
:S
CA
LE
:
LL 80
CO
WE
TA
C
OU
NT
Y
SH
EE
T:
PR
OJE
CT
:
DR
AW
IN
G N
O:
DE
SC
RIP
TIO
N:
DA
TE
:R
EV
.
PH
: (7
70
)-4
73
-9
57
6
ge
org
e@
pa
ra
mo
un
te
ng
in
ee
rin
g.co
m
11
E
. B
RO
AD
S
T.
NE
WN
AN
, G
A. 3
02
63
SHEET
6T
H D
IS
TR
IC
T
02-12-18
280201- P
EP
PE
RT
RE
E
GSWCC NO. 09374
AD
DR
ES
SE
D C
IT
Y/ H
CW
A C
OM
ME
NT
S05-24-18
1
RE
V. LA
YO
UT
/ A
DD
ED
A
CR
EA
GE
08-28-18
2
1" =
6
0'
3
LE
VE
L III S
OIL
R
EP
OR
T
NOTES:
System installation should not occur under saturated soil conditions
Absorption fields should not be installed on concave slopes.
Surface drainage should be diverted away from absorption field lines.
Gutter downspouts should be discharged away from the vicinity of the on
site wastewater system.
Estimated percolation rates are based on full-sized system performance.
However, no guarantee is given or implied as to the performance of any
particular system installed.
O1
C1
SOIL SUITABILITY LEGEND
A1Soils are typically suitable for conventional absorption field with proper design, installation and maintenance.
Soils consist of local alluvium or wash over wash over natural soils. Residual soil is suitable for conventional absorption field installation at
recommended trench depth. Storm water runoff must be diverted from this area if it is used for absorption field.
Soils are typically suitable for conventional absorption field with proper design, installation and maintenance. The Bt horizon shows some
evidence of slow percolation, subsoil is well drained. Trenches installed at the recommended depth should function effectively.
Soils are unsuitable for conventional absorption fields due to perched water table conditions. Soils are generally suitable for alternative
absorption fields with treatment system producing Class 1 effluent.
Soils are unsuitable for conventional absorption fields due to seasonal-high water table conditions. Soils are generally suitable for alternative
absorption fields with treatment system producing Class 1 effluent.
Soils are unsuitable for on-site wastewater disposal due to seasonal high water table.
Soils are located in a landscape position that renders them unsuitable for on-site wastewater disposal due to flooding and/ or storm water
drainage patterns.
Soils consist of a mixture of filled and cut soils. Further investigation of test pits dug with a backhoe should be conducted in this area to
determine the suitability of soils for septic system construction..
Soils contain somewhat shallow parent material and weathered rock. Hand auger borings have been advanced to a depth of 5 feet and
parent material is generally suitable for conventional absorption field installation. Estimated perc rate accounts for presence of seams of
weathered rock.
Soils show evidence of a somewhat restrictive layer in the upper part of the profile. Brief perching of water may cause problems for
absorption fields installed in the upper part of the soil profile. Soil below somewhat restrictive layer appear to be well drained with texture and
structure that should provide a suitable percolation rate. Conventional absorption field installed below restrictive layer should function
effectively. Environmental Health Department may require further inspection utilizing backhoe test pits prior to permitting.
Soils are typically suitable for conventional absorption field with proper design, installation and maintenance. Absorption trenches must be
installed at least 24 inches above seasonal high water table to function effectively. Seasonal high water table indicators were observed
between 54 and 60 inches. Installations deeper than 30 inches may require a treatment system producing Class 1 effluent.
C2
P1
A5
F4
F2
Estimated Perc Rate
(min/in)
Slope
Gradient
(percent)
Soil
Suit.
Code
Depth to Seasonal
High
Water Table (in)
Depth to
Bedrock
(in)
Soil Units
SOIL INTERPRETIVE DATA
Recommended
Trench
Depth (in)
>72
24-30
(PWT)
12 C12-10 Cataula II
>72 >72 30-48 A12-10 Cecil60
>72 36 18-24 C22-10 Hard Labor II75
>72 >72 36-48 A21-5
Wash Over
Cecil
60
>72 16-24 F46-15 Abell
75
----
Recommended
Hydraulic
Loading Rate
(gal/day/sq.ft.)
0.10
0.15
*INDICATES DEPTH TO TOP AND BOTTOM OF RESTRICTIVE LAYER THAT IS CAUSING BRIEF PERCHING OF WATER TABLE. SOIL APPEARS TO BE WELL
DRAINED BELOW RESTRICTIVE LAYER.
PWT = Perched Water Table
P14-8
Cecil
Wet Variant
54-60>72
24-30
>72
24-42*
(PWT)
54-72 O12-10 Cataula III70
----
----
----
----
------------
>72 24 12 C22-10 Hard Labor I90
0.10
>72 >72 ---- F42-6 Starr----
----
>72 >72 30-48 A12-12 Pacolet45
----
>72 >72 40-60 A52-10
Cecil
Variant
60----
A2
>72 >72 ---- F5C1-5 Udorthents----
----
>60 >60 N36-15 Bethlehem ----7024-36
F5C
N3