Upload
others
View
4
Download
0
Embed Size (px)
Citation preview
ICE
A
A
A
A
EX
EX
EX EXH-EME
H-EME
H-EME
H-EME
H-EME
H-EME
H-EME
H-EME
H-EME
H-EME
H-EME
SIXTH FLOOR PLAN
SCALE: 1/8" = 1'-0"
MECH.
ACCESSORY 1/300 SF.
151 SF 1 OCC.
GUESTROOMS
R-1 (RESIDENTIAL) 1/200 SF.
1465 SF 8 OCC.
(2 MEANS OF EGRESS REQ'D)
GUESTROOMS
R-1 (RESIDENTIAL) 1/200 SF.
1410 SF 8 OCC.
(2 MEANS OF EGRESS REQ'D)
GUESTROOMS
R-1 (RESIDENTIAL) 1/200 SF.
3387 SF 17 OCC.
(2 MEANS OF EGRESS REQ'D)
MECH.
ACCESSORY 1/300 SF.
183 SF 1 OCC.
STAIR #1
618
STAIR #2
619
KING
600
KING
601
KING
SOFA
602
KING
SOFA
603
DOUBLE
QUEEN
604
DOUBLE
QUEEN
605
DOUBLE
QUEEN
606
DOUBLE
QUEEN
607
DOUBLE
QUEEN
610
DOUBLE
QUEEN
611
KING
SOFA
612
KING
SOFA
613
KING
614
KING
SOFA
615
KING
616
KING
617
HOUSE
KEEPING
620
CORRIDOR
621
VEND.
622
ELEV.
LOBBY
624
CORRIDOR
627
STOR.
628
ELEC.
626
LINEN
CHUTE RM.
623
TEL.
625
DOUBLE
QUEEN
609
18 OCC.
TRAVEL DISTANCE: 94'-10"
18 OCC.
TRAVEL DISTANCE: 90'-9"
DEAD
END
DIS
TANC
E: 1
7'-10
"
MECH.
ACCESSORY 1/300 SF.
106 SF 1 OCC.
FE
FE
FE
ICE
A
A
A
A
EX
EX
EX EXH-EME
H-EME
H-EME
H-EME
H-EME
H-EME
H-EME
H-EME
H-EME
H-EME
H-EME
FIFTH FLOOR PLAN
SCALE: 1/8" = 1'-0"
MECH.
ACCESSORY 1/300 SF.
151 SF 1 OCC.
GUESTROOMS
R-1 (RESIDENTIAL) 1/200 SF.
1465 SF 8 OCC.
(2 MEANS OF EGRESS REQ'D)
GUESTROOMS
R-1 (RESIDENTIAL) 1/200 SF.
1410 SF 8 OCC.
(2 MEANS OF EGRESS REQ'D)
GUESTROOMS
R-1 (RESIDENTIAL) 1/200 SF.
3387 SF 17 OCC.
(2 MEANS OF EGRESS REQ'D)
MECH.
ACCESSORY 1/300 SF.
183 SF 1 OCC.
STAIR #1
518
STAIR #2
519
KING
500
KING
501
KING
SOFA
502
KING
SOFA
503
DOUBLE
QUEEN
504
DOUBLE
QUEEN
505
DOUBLE
QUEEN
506
DOUBLE
QUEEN
507KING
509
DOUBLE
QUEEN
510
DOUBLE
QUEEN
511
KING
SOFA
512
KING
SOFA
513
KING
SOFA
514
KING
SOFA
515
KING
516
KING
517
HOUSE
KEEPING
520
CORRIDOR
521
VEND.
522
ELEV.
LOBBY
524
CORRIDOR
527
STOR.
528
ELEC.
526
LINEN
CHUTE RM.
523
TEL.
52518 OCC.
TRAVEL DISTANCE: 94'-10"
18 OCC.
TRAVEL DISTANCE: 90'-9"
DEAD
END
DIS
TANC
E: 1
7'-10
"
MECH.
ACCESSORY 1/300 SF.
106 SF 1 OCC.
FE
FE
FE
A-702
LIFE SAFETY FLOOR PLAN
35 OCCUPANTS
OCC. LOADOCC.PER
SQ.FTAreaSPACE/Occupant Type(From IBC Table 1004.1)
SIXTH FLOOR OCCUPANT LOAD
2 OCCUPANT1/300334 SFACCESSORY
32 OCCUPANT6262 SFR-1 (RESIDENTIAL) 1/2006,596 SFTOTAL OCCUPIED & OCCUPANT SQ.FT.
35 OCCUPANTS
OCC. LOADOCC.PER
SQ.FTAreaSPACE/Occupant Type(From IBC Table 1004.1)
FIFTH FLOOR OCCUPANT LOAD
2 OCCUPANT1/300334 SFACCESSORY
32 OCCUPANT6262 SFR-1 (RESIDENTIAL) 1/2006,596 SFTOTAL OCCUPIED & OCCUPANT SQ.FT.
1 OCCUPANT1/300106 SFACCESSORY
1 OCCUPANT1/300106 SFACCESSORY
10# FIRE EXTINGUISHER INRECESSED CABINETFE
CONCRETE BLOCK OR CONCRETEWALL (2 HR )
NON COMBUSTIBLE GYPSUM BDPARTITION
1 HR GYPSUM BD PARTITION
2 HR GYPSUM BD PARTITION
2 HR SHAFT WALL
AND W/ SHATTEROMS)
LIGHT W/ INTERIOR WALL SC
IMMABLE, 42W,RD DOWNLIGHT
COMPACT LED DOWN Q
APPLICABLE CODESFLORIDA BUILDING CODE 2010BUILDING 2010ACCESSIBILITY 2010PLUMBING 2010ELECTRICAL 2010MECHANICAL 2010FLORIDA FIRE PREVENTION CODE (FFPC) 2010 EDITION WITH BROWARD COUNTYAMENDMENTS, WHICH INCLUDES NFPA 101, 2009 EDITION, NFPA 1, 2009 EDITION & STATESTATUES, 2010 EDITION.
CONSTRUCTION TYPE: TYPE IB (SPRINKLER, NFPA - 13)
OCCUPANCY: MIXED OCCUPANCY AND NONSEPARATED USE (508)
A-2 - ASSEMBLY (303.1) - GROUND FLOOR ONLY
R-1 - RESIDENTIAL (310.1)
ALLOWABLE HEIGHT & AREAS (TABLE FBC 503) 160' HEIGHT, 11 STORIES, UNLIMITED SQ. FT./FLOOR
ACTUAL BUILDING HEIGHT & AREA: 76'-8" HEIGHT, 7 STORIES
THE BUILDING IS EQUIPED THROUGHOUT WITH AN APPROVED AUTOMATIC SPRINKLER SYSTEM INACCORDANCE WITH SECTION 903.3.1.1 (NFPA 13)
EXIT TRAVEL DISTANCE: 200' (TABLE FBC 1016.1)
DEAD END CORRIDORS: 50' (FBC 1018.4, EXCEPTION 2)
(FFPC) FLORIDA FIRE PROTECTION CODE NFPA 101 28.2.5.6 "DEAD-END CORRIDORS SHALL NOT EXCEED50 FT. THE "COMMON PATH SHALL NOT EXCEED 50' AS PER NFPA 101-28.2.5.4.
NUMBER OF EXITS REQUIRED: 2 (FBC TABLE 1021.1) 2 PROVIDED.
ELEVATOR HOISTWAY VENTING: NOT REQUIRED (FBC 3004, EXCEPTION 1)
THE CONTENTS OF RESIDENTIAL OCCUPANCIES SHALL BE CLASSIFIED AS ORDINARYHAZARD IN ACCORDANCE WITH 6.2.2 AS PER NFPA 101-28.1.5.1.
UL 300 HOOD SIPPRESSION SUSTEM NOT REQUIRED. NO COOKING IS DONE ON PREMESIS. ONLY ACONTINENTAL BREAKFAST IS PROVIDED.
ALL DOORS IN THE MEAN OF EGRESS SHALL BE SINGLE ACTION RELEASE AND SHALL NOT REQUIRE THEUSE OF A KEY, TOOL, OR SPECIAL KNOWLEDGE TO OPEN FROM EGRESS.
FIRE EXTINGUISHERS SHALL BE MOUNTED NOT TO EXCEED 48" AFF AND SHALL BE CURRENTLY DATEDAND TAGGED BY LICENSED FIRE EQUIPMENT COMPANY.
ADDITIONAL EXIT SIGNS AND EMERGENCY LIGHTS MAY BE REQUIRED BY THE FIRE INSPECTOR AT THETIME OF THE FIRE FINAL.
STAIRWAY IDENTIFICATION SHALL COMPLY WITH NFPA 101-7.2.2.5.4.1 (A) THROUGH (M)
1 08/07/2015 FIRST CITY COMMENTS BID SET