Upload
sfkryti
View
14
Download
0
Embed Size (px)
DESCRIPTION
ILS
Citation preview
Slide *Periodic Maintenance schedule
Slide *NOTE!The content of and periode between procedures given are Park Air Systems recomondations under normal operational environment.
The responsible Authority may have requirements that replaces, modifies or comes in addition to the procedures given.
Slide *On-site performance checks
Monthly Six Monthly Annual
Slide *Other On-site maintenance
Clean and inspectEquipmentinspect batteries for corrosion, cracks, and other deteriorationcheck and tighten RF and battery connections as requiredCheck any installed environmental sensors and other equipment connected to user analog or digital inputs for proper operationCheck operation of interlocks, if installedCheck operation of remote controls if installed
Slide *Off-site maintenance
All module and circuit board repair is to be performed off site, at the factory or authorized repair depotNo modules are user-serviceable
Slide *Periodic maintenance
No adjustmens / alignments shall be done during a Periodic MaintenanceThe parameters should be recorded and compared with their nominal values only
Slide *Monthly
Observe and record monitor data (both Txs)No alarms or warningsObserve Maintenance parameters (both Txs)No alarms or warningsField DDM measurementsAs established for facilityCourse Structure along runway (CAT III)As established for facilityTest equipmentPIRPC
Slide *Six Monthly
Tx parameters and DC supply recordingsAs established at installation and flight inspectionMonitor Integrity CheckChange Over / Shut DownTest equipmentOscilloscopeStop watchPCThe Monitor Integrity Check is a special check to verify that the Terminator part of the TCA1218 board is working correctlyThe check has to be carried out to fulfil the Continuity of Service requirements in Annex 10
Slide *Annual
RF Frequency check (Course/CLR both Txs)adjusted frequency +/-0.002%LF Frequency check (Course/CLR both Txs)+/-0.05Hz
Test equipmentOscilloscopePIRPCFrequency counterRF signal generator (ILS mod)Dig. VoltmeterPower MeterStop watch
Slide *Annual
Tx waveform check (CSB / SBO)As indicated on drawingsTx modulation check (DDM / SDM / Ident)As established for facilityCSB output powerAs established for facilityMonitor Alarm limits checkUsing Flight Check test signals CAT I / IIUsing RF Signal Generator (ILS mod) CAT III
Slide *Annual
Near Field monitor delayAs set +/-2 seconds20 seconds inhibitbetween 20 22 secondsBattery maintenancePer battery specificationFinal checkVisual inspection
SHARING AND DISCUSSIONSlide *