16
Product Features • Compact design • Quick change of cassette (SR10)/ tubing (SR25) • Infinite tubing possible • Self priming • Safe to run dry • Maintenance free • Left- and right handed run (only DC drive) • Different tubing materials Range of applications • Chemical industry • Medical industry • Laboratory and analysis technology • Food sector • Hygiene, desinfection Peristaltic Pumps Series SR 10 · SR 25 SR 10/30 ® SR 25

Peristaltic Pumps Series SR 10 · SR 25 Features • Compact design • Quick change of cassette (SR10)/ tubing (SR25) • Infinite tubing possible • Self priming • Safe to run

Embed Size (px)

Citation preview

Page 1: Peristaltic Pumps Series SR 10 · SR 25 Features • Compact design • Quick change of cassette (SR10)/ tubing (SR25) • Infinite tubing possible • Self priming • Safe to run

Product Features• Compact design

• Quick change of cassette (SR10)/tubing (SR25)

• Infinite tubing possible

• Self priming

• Safe to run dry

• Maintenance free

• Left- and right handed run (only DC drive)

• Different tubing materials

Range of applications• Chemical industry

• Medical industry

• Laboratory andanalysis technology

• Food sector

• Hygiene, desinfection

Peristaltic PumpsSeries SR 10 · SR 25

SR 10/30

®

SR 25

Page 2: Peristaltic Pumps Series SR 10 · SR 25 Features • Compact design • Quick change of cassette (SR10)/ tubing (SR25) • Infinite tubing possible • Self priming • Safe to run

SR25

Gear box

4 roll carrier(optional)with spring

Tubing withconnectorsRolling

band

Pumpbody

Clamp

2

FunctionalDescription

Flow Range

®

SR10

SR25SR10

• No gear necessary.

• Speed reduction through friction from the motorshaft to the rolls.

• Very easy construction with the use of only a few parts.

• Quick change of the cassette.

• Use of only 3 rollers.

• Only for short time operation.

• If storing longer than three month, we recommendto take the cassette off the motor shaft and store itseparately.

Important

We recommend an additional control unitfor the use as a dosing pump.

Motor

Bracket

Lid

Tubing

Rollers

Pump body

• Different gear motors possible.

• Reduction of nominal speed through a gear box.

• Protection of the tubing using spring loaded rollers

and guiding side rollers.

• Quick tube changing.

• Roll carrier with 2 rollers, optional with 4 rollers.

• Depending on the drive also for continuous operation.

• If storing longer than three months, we recommendto remove the tubing of the SR 25.

55 ml/min

16 ml/min

ml/min

SR10/30page 4

SR10/50page 5

SR10/100page 6

220 ml/min

52 ml/min

2900ml/min

650 ml/min

287ml/min

2.3ml/min

SR25 DCpage 10

746ml/min

1 ml/min

SR25 ACpage 9

only55

ml/min

SR50page 13

21ml/min

0.18ml/min

SR25 Synchr.page 8

Suction height 8 mWCPressure height 8 mWC

Suction height 8 mWCPressure height10 mWC

Page 3: Peristaltic Pumps Series SR 10 · SR 25 Features • Compact design • Quick change of cassette (SR10)/ tubing (SR25) • Infinite tubing possible • Self priming • Safe to run

Duty CycleSR10SR10/30 and SR10/50Drive: Permanentmagnetmotor (DC)

SR25

Drive: Permanentmagnetmotor (DC)

5 10 15

510

15

6012

0

60 120

für Dauerbetriebgeeignet

5 10 15

510

152

0

20

6012

0

60 120

für Dauerbetriebgeeignet

20 40 60

12

34

5 10 15

510

1520

20

SR10/30 and SR10/50Drive: Shaded pole motor (AC) Drive: Shaded pole motor (AC)

SR10/100 Drive: Synchronousmotor

recommended operating range

Cassette with tubeh 4000

2000

1000

0Viton® Silicon Novoprene

Norprene®

Pharmed®

NovopreneNorprene®

Pharmed®

SR10/30SR10/50

SR10/30SR10/50

SR10/30SR10/50 SR10/100

tube (at 10 RPM)

Viton® Silicon NovopreneNorprene®

Pharmed®

Life ExpectancySR25SR10gear motor 10 RPMh

10000

5000

1000

0SR50 SR25 DC

SR25 ACSR25

Synchronous-motor

op

erat

ion

tim

e in

min

.

op

erat

ion

tim

e in

min

.

OFF time in min. OFF time in min.

suitable for continuous running

suitable for continuous running

OFF time in min.

op

erat

ion

tim

e in

min

.

op

erat

ion

tim

e in

min

.

OFF time in min.

op

erat

ion

tim

e in

min

.

OFF time in min.

op

erat

ion

tim

e in

min

.

OFF time in min.

Page 4: Peristaltic Pumps Series SR 10 · SR 25 Features • Compact design • Quick change of cassette (SR10)/ tubing (SR25) • Infinite tubing possible • Self priming • Safe to run

4 ®

Peristaltic Pump SR10/30only for short time operation

Technical Data

Physical Data

Tubing Novoprene Tubing Pharmed® Fixing Inner Tubing Ø Flow1)

12 V DC 24 V DC 230/50 Hz 12 V DC 24 V DC 230/50 Hz mm ml/min

20300312* 20300342* 20300512 20300542 straight 1.0 1620300313* 20300343* 20300361* 20300513 20300543 20300561 angled20300314 20300344 20300514 20300544 straight 1.5 2820300315 20300345 20300362 20300515 20300545 20300562 angled20300316 20300346 straight 2.0 3820300317 20300347 20300363 angled20300318 20300348 20300235 20300237 straight 2.5 5520300319 20300349 20300364 20300236 20300238 20300239 angled

Tubing Silicon Fixing Inner Tubing Ø Flow1)

12 V DC 24 V DC 230/50 Hz ml/min

20300412 20300442 straight 1.0 1620300413 20300443 20300461 angled20300414 20300444 straight 1.5 2820300415 20300445 20300462 angled20300416 20300446 straight 2.0 3820300417 20300447 20300463 angled20300418 20300448 straight 2.5 5520300419 20300449 20300464 angled

~35 (~1.38)

48 (1.89)

56 (2.20)

4.3

(.17)

13 (.51)

47.5 (1.87)

80 (3.16)

17.5

(.69

)

9 (.36)

63 (2

.48)

34 (1

.34)

58 (2.28)

Option: high quality DC motor,stepper motor

current consumption depending on the tubing diameter, at free flow and nominal voltage 12 V DC: 180 – 300 mA

24 V DC: 90 – 150 mA230 V/50 Hz: 170 mA

SR10/30 DCangled fixing(straight without illustration)interference suppression according toEN 55011 B (CE-konform)

SR10/30 AC

1) Note: The indicated values are average. The actual values depend on different parameters like quality and age of tubing, pressure oftubing beds, pressures proportions, viscosity, etc. Please also have a look on page 2 regarding the recommendedrunning times.

* Tubing Norprene

Illu

stra

tion

112

44Ill

ust

ratio

n 1

5151

Illu

stra

tion

1123

6

16 – 55 ml/min

Page 5: Peristaltic Pumps Series SR 10 · SR 25 Features • Compact design • Quick change of cassette (SR10)/ tubing (SR25) • Infinite tubing possible • Self priming • Safe to run

Option: Straight flange for flush mounting part number 20501...Recommended inference suppression according to EN 55011 B (CE-conform)12/24 V DC – with additional circuit board 29004264

current consumption depending on the tubing diameter, at free flow and nominal voltage 12 V DC: 0.4 – 0.54 A

24 V DC: 0.2 – 0.27 A230 V/50 Hz: 0.27 A

1) Note: The indicated values are average. The actual values depend on different parameters like quality and age of tubing, pressure oftubing beds, pressures proportions, viscosity, etc. Please also have a look on page 2 regarding the recommendedrunning times.

Peristaltic Pump SR10/50only for short time operation

Tubing Novoprene Tubing Pharmed® Inner Tubing Ø Flow1)

12 V DC 24 V DC 230/50 Hz 12 V DC 24 V DC 230/50 Hz mm ml/min

20500717 2.0 5220500701 20500704 70

20500519 20500718 2.4 7520500501 20500505 20500702 20500705 100

20500520 3.2 11020500502 20500506 170

20500521 20500719 4.1 16520500503 20500507 20500703 20500706 220

Tubing Silicon Inner Tubing Ø Flow1)

12 V DC 24 V DC 230/50 Hz mm ml/min

20500619 2.0 5220500601 20500605 70

20500620 2.5 7520500602 20500606 100

20500621 4.0 16520500603 20500607 220

2x

409

4,11

3,

USpat.

10/50

SR

4x

42 (1.65)

4.3

(.17)

49.7

(1.9

6)¯ 56

(2.2

0)

86.5

(3.4

1)

85 (3.35)

40.5 (1.59)

7 (.28)

60 (2.36)

57 (2

.24)

56 (2.20)

48 (1.89)

32.5 (1.28)

42 (1

.65)

4.3

(.17)

12.5

(.49

)

10 (.

39)

~70

(2.7

6)

2x

409

4,11

3,

USpat.

10/50

SR

+_

4x

4.3

(.17)

32.5 (1.28)

12.5

(.49

)

60 (2.36)

57 (2

.24)

56 (2.13)

48 (1.89)

49.7

(1.9

6)¯ 56

(2.2

0)

40.5 (1.59)

7 (.28)

36(1

.42)

¯

29(1.14)

84 (3.31)

42 (1.57)

4.3

(.17)

10 (.

39)

~70

(2.7

6)42

(1.6

5)

Illu

stra

tion

106

73Ill

ust

ratio

n 1

0250

Technical Data

Physical Data

SR10/50 DC

SR10/50 AC

52 – 220 ml/min

Page 6: Peristaltic Pumps Series SR 10 · SR 25 Features • Compact design • Quick change of cassette (SR10)/ tubing (SR25) • Infinite tubing possible • Self priming • Safe to run

6 ®

Peristaltic Pump SR10/100only for short time operation

Technical Data

Physical Data

150∞C150±5K

AUF OPEN

CLOSEZU

M~

schwarz (black)

blau (blue)

braun (brown)

~30

(1.1

8)

(1.1

8)

63 (2.48)

110

(4.3

3)

70 (2

.76)

¯

30

63 (2.48)

15 (.59)¯50 (1.97)

112

(4.4

1)

99 (3.90)

72 (2.83)10

7 (4

.22)

54 (2

.13)

109 (4.31)57 (2.28)

105

(4.1

2)

164 (6.46)

CLOSEZU

PuchheimASF

pat. US 4,113,409

AUFOPEN

Montagewinkel entfällt

bei Ausführung -Schottmontage-

flush mounting

is without bracket

Litzen (wires)

300mm

0.75mmm = AWG182

107.

5 (4

.16)

72 (2.83)

112.

5 (4

.43)

109

(4.2

9)

42 (1

.65)

¯

118.

5 (4

.66)

()

50 (1.97)106 (4.17)

27.5 (1.08)

26.5 (1.04) 77.5 (3.05)

143 (5.63)

~30

(1.1

8)

10 (.39)25 (.98)

7(.2

8)92

(3.9

0)

Option: Recommended inference suppression according to EN 55011 B (CE-conform)12/24 V DC – with additional circuit board 29004256

current consumption at free flow and nominal voltage 12 V DC: 3.0 A24 V DC: 1.5 A230 V/50 Hz: 0.4 A

Illu

stra

tion

137

76Ill

ust

ratio

n 1

3591

SR10/100 AC

NEWAlso availablewith a IP54 motor,cable and plug

SR10/100 DCWith bracket

Tubing Norprene® Tubing Pharmed® Fixing Inner Tubing Ø Flow1)

12 V DC 24 V DC 12 V DC 24 V DC mm l/min

21001006 21001007 21001106 21001107 bracket 6.35 1.321001012 21001013 21001112 21001113 flush mount21001008 21001009 21001108 21001109 bracket 8.0 2.321001014 21001015 21001114 21001115 flush mount21001010 21001011 21001110 21001111 bracket 9.5 2.921001016 21001017 21001116 21001117 flush mount

Tubing Norprene® Tubing Pharmed® Motor speed Inner Tubing Ø Flow1)

230V/50 Hz 230V/50 Hz 1/min mm l/min

21001018 21001118 1400 6.35 0.6521001019 21001119 1400 8.0 1.1521001020 21001120 1400 9.5 1.4521001000 21001100 2800 6.35 1.321001001 21001101 2800 8.0 2.321001002 21001102 2800 9.5 2.9

1) Note: The indicated values are average. The actual values depend on different parameters like quality and age of tubing, pressure oftubing beds, pressures proportions, viscosity, etc. Please also have a look on page 2 regarding the recommendedrunning times.

650 – 2900 ml/min

Page 7: Peristaltic Pumps Series SR 10 · SR 25 Features • Compact design • Quick change of cassette (SR10)/ tubing (SR25) • Infinite tubing possible • Self priming • Safe to run

7

Spare Cassettes

®

Tubing DriveDirect AlternatingCurrent Current

Norprene 1.0 x 1.1 mm 92030516 92030515Novoprene® 1.5 x 1.0 mm 92030703 92030514Novoprene 2.0 x 1.0 mm 92030702 92030513Novoprene 2.5 x 1.0 mm 92030701 92030704

Pharmed® 1.0 x 1.1 mm 92030548 92030604Pharmed 1.5 x 1.1 mm 92030534 92030549Pharmed 2.5 x 1.0 mm 92030611 92030603

Silicon 1.0 x 1.0 mm 92030800 92030505Silicon 1.5 x 1.0 mm 92030802 92030554Silicon 2.0 x 1.0 mm 92030804 92030555Silicon 2.5 x 1.0 mm 92030806 92030553

Novoprene 2.4 x 1.6 mm 92050576Novoprene 3.2 x 1.6 mm 92050577Novoprene 4.1 x 1.6 mm 92050578

Pharmed® 2.0 x 1.6 mm 92050585Pharmed® 2.4 x 1.6 mm 92050586Pharmed® 4.0 x 1.6 mm 92050587

Silicon 2.0 x 1.6 mm 92050581Silicon 2.5 x 1.6 mm 92050582Silicon 4.0 x 1.6 mm 92050583

Norprene® 6.35 x 2.4 mm 92100512Norprene® 8.0 x 2.4 mm 92100504Norprene® 9.5 x 2.4 mm 92100501

Pharmed® 6.35 x 2.4 mm 92100515Pharmed® 8.0 x 2.4 mm 92100516Pharmed® 9.5 x 2.4 mm 92100517

Model SR10/30

Model SR10/50

Model SR10/100

Page 8: Peristaltic Pumps Series SR 10 · SR 25 Features • Compact design • Quick change of cassette (SR10)/ tubing (SR25) • Infinite tubing possible • Self priming • Safe to run

8 ®

Peristaltic Pump SR25 Synchr.230 V/50Hz, synchronousmotor, for continuous operation

Technical Data

Physical Data

ZUA

UF

47 (1.85)63 (2.48)

80 (3.15)

5.5(.22)

50 (1

.97)

70 (2

.76)

18

(.7

1)

20

(.7

9)

86

.5 (

3.4

1)

10

1 (

3.9

8)

5 (.20)¯

19.5 (.77)

59

(2

.32

)

3 (

.12

)

31

(1

.22

)

39

.5 (

1.5

6)

93

(3

.66

)

95

(3

.72

)

14 (.55)

7 (.28)

(41 (1.61))

(31 (1.22))(61 (2.37))

20 (.79)

92 (3.59)

36.5 (1.44)

SinkingSenkung DIN74-Bf32x

2x Gewindebolzen M3x102x threated bolt M3x10Art.-Nr.: 80011110

Benötigte Wandstärke 3mmnecessary wall thickness 3mm

13

.5±0

.1

47.6 ±0.1

63.5( )

63

.5(

)

25

()

55 ±0.1

12.1+0.1

8±0

.1

Illu

stra

tion

126

43Ill

ust

ratio

n 1

3865

bore pattern to fitin a housing

Nominal speed1 RPM 5 RPM 10 RPM 15 RPM

Tubing Novoprene Flow1) ml/minN1.6 x 1.6 mm 0.18 1.0 1.9 2.8part number 20251737 20251350 20251354 20251769N3.2 x 1.6 mm 0.68 3.4 7.0 10.5part number 20251738 20251351 20251355 20251770N4.1 x 1.6 mm 1.0 5.0 10 15part number 20251739 20251352 20251356 20251771N4.8 x 1.6 mm 1.3 6.8 14 21part number 20251740 20251353 20251357 20251772Electrical datamotor voltage 230 (115) V/50–60 Hzmotor synchronousisolation class Enominal speed 7.5 WGeneral dataprotection class IP00weight 0.39 kg

order code: SR25 - 10 RPM / N4,8 x 1,6

type

nominal speed

tubing quality:S = SiliconN = Novoprene

inner Ø x wall thickness

Material of tubing connectors: 2025... stock programTubing Novoprene : Ø 1.6/3.2 mm – PVC

Ø 4.1/4.8 mm – PP

SR25 1 bis 15 RPMSynchronousmotor

1) Note:

The indicated values are average. The actual valuesdepend on different parameters like quality and age oftubing, pressure of tubing beds, pressures proportions,viscosity, etc. Please also have a look on page 2 regarding the recommended running times.

blue

230V

red

blue

115V

white

Electrical wiring: Option:

0,18 – 21 ml/min

Page 9: Peristaltic Pumps Series SR 10 · SR 25 Features • Compact design • Quick change of cassette (SR10)/ tubing (SR25) • Infinite tubing possible • Self priming • Safe to run

Peristaltic Pump SR25 AC230 V/50Hz, shaded pole motor, short time operation

115.5 (4.55) 5-80Upm (Rpm)

2x

C

A

nur bei 170Upmonly at 170Rpm

15 (.

57)

123.5 (4.86) 170Upm (Rpm)

19.5 (.77)

63 (2.48)

5 (.20)¯

36.5 (1.44)

101

(3.9

8)

80 (3.15)

70 (2.76)

5.5 (.22)¯

18 (.

71)

59 (2.32)2 (.08) 7 (.28)

2x

A

C

18 (.

71) 10

1 (3

.98)

21.5 (.85)

153.5 (6.04)

7 (.28)61 (2.40)

70 (2.76)

80 (3.15)

ø5 (.20)

36.5 (1.44)

64.5 (2.54)

95 (3

.74)

15 (.

59)

108

(4.2

3)

ø5.5 (.22)

Illu

stra

tion

127

27Ill

ust

ratio

n 1

2735

SR25–500 RPMShaded pole motor

SR25 5 bis 170 RPMShaded pole motor

Nominal speed5 RPM 10 RPM 30 RPM 65 RPM 80 RPM 170 RPM 500 RPM

Tubing Novoprene Flow1) ml/minN 1.6 x 1.6 mm 1.0 1.9 5.6 12 15part number 20250001 20250875 20250009 20250013 20250893N 3.2 x 1.6 mm 3.4 7.0 21 47 56 113 374part number 20250002 20250873 20250010 20250014 20250892 20250900 20250916N 4.1 x 1.6 mm 5 10 30 68 85 170 545part number 20250869 20250007 20250881 20250886 20250891 20250899 20250914N 4.8 x 1.6 mm 6.8 14 40 90 110 220 690part number 20250744 20250872 20250880 20250884 20250020 20250898 20250913Tubing Silicon Flow1) ml/minS 2.0 x 1.0 mm 1.5 2.9 8.8 20 24part number 20250871 20250879 20250883 20250890 20250897S 3.0 x 1.0 mm 2.8 5.4 16 36 43part number 20250520 20251026 20250882 20250889 20250896S 4.0 x 1.5 mm 5.4 11.0 32 70 86 173 546part number 20250519 20250877 20251280 20250888 20250895 20250904 20250920S 5.0 x 1.5 mm 7.5 15.0 45 88 119 239 746part number 20250870 20250876 20250047 20250887 20250057 20250903 20250919Electrical datamotor voltage 230 V/50 Hz 230 V/50 Hz 230 V/50 Hzmotor shaded pole motor shaded pole motornominal speed 16 watts 27 watts 68 wattsisolation class E E EGeneral dataprotection class IP00 IP00 IP00weight 0.7 kg 0.85 kg 1.5 kg

Technical Data

Physical Data

order code: SR25 - 10 RPM / N4,8 x 1,6

type

nominal speed

tubing quality:S = SiliconN = Novoprene

inner Ø x wall thickness 2025... stock programMaterial for tubing connectors:Tubing Silicon : for all Ø PVCTubing Novoprene : Ø 1.6/3.2 mm – PVC

Ø 4.1/4.8 mm – PP

1,0 – 746 ml/min

Page 10: Peristaltic Pumps Series SR 10 · SR 25 Features • Compact design • Quick change of cassette (SR10)/ tubing (SR25) • Infinite tubing possible • Self priming • Safe to run

10 ®

Peristaltic Pump SR25 DC12/24 V, direct current motor

Technical Data

Physical Data

A

C

2x59 (2.32)

18 (.

71)

66.5 (2.62)

133 (5.24)

19.5 (.77)

5.5 (.22)¯

70 (2.76)80 (3.15)

101

(3.9

8)

36.5 (1.44)

5 (.20)¯

63 (2.48)

31 (1

.26)

¯

31.5

(1.2

2)

15 (.

59)

7 (.28)

A

C

2x61 (2.40)

18

(.7

1)

66.5 (2.62)

135 (5.32)

21.5 (.85)

5.5 (.22)¯

70 (2.76)

80 (3.15)

10

1 (

3.9

8)

36.5 (1.44)

5 (.20)¯

63 (2.48)

31

(1

.26

31

.5 (

1.2

2)

15

(.5

9)

7 (.28)

Illu

stra

tion

127

29Ill

ust

ratio

n 1

3334

SR25 –170 RPMDirect current motor

SR25 5 to 80 RPMDirect current motor

Material of tubing connectors:tubing Silicon : for all Ø PVCtubing Novoprene : Ø 1.6/3.2 mm - PVC

Ø 4.1/4.8 mm - PP

Option: Recommended inference suppression according to EN 55011 B (CE-conform)12/24 V DC – with additional circuit board 29002445

* on request

2025... stock program

Nominal speed10 RPM 30 RPM 65 RPM 80 RPM 170 RPM

Tubing Novoprene Flow (1) ml/minN1.6 x 1.6 mm 2.3 6.7 14.4part number 12 V 20250988 20251397 20251410 – *part number 24 V 20251388 20251401 20250266 * *N3.2 x 1.6 mm 8.4 25 56 67part number 12 V 20251387 20251398 20251411 – *part number 24 V 20251371 20251255 20251412 20251425 *N4.1 x 1.6 mm 12.0 36 82 102 204part number 12 V 20250088 20251399 20250083 – 20251261part number 24 V 20251389 20251402 20250082 20251010 20250396N4.8 x 1.6 mm 17 48 118 132 264part number 12 V 20251325 20251400 20250426 – 20251224part number 24 V 20251247 20251403 20251413 20250287 20250130Tubing Silicon Flow (1) ml/minS2.0 x 1.0 mm 3.5 10.6 24part number 12 V 20251390 20251404 20251414 – *part number 24 V 20251394 20251407 20251418 * *S3.0 x 1.0 mm 6.5 19 43 52part number 12 V 20251391 20251405 20251415 – *part number 24 V 20251395 20251408 20251419 20251433 *S4.0 x 1.5 mm 13 38 84 103 208part number 12 V 20251392 20250302 20251416 – 20250228part number 24 V 20251396 20251409 20250746 20251434 20250901S5.0 x 1.5 mm 18 54 116 143 287part number 12 V 20251393 20251406 20251417 – 20251441part number 24 V 20250092 20251366 20251420 20251435 20251444Electrical datamotor direct current motornominal speed 2 W 3.5 W 7 WGeneral dataweight 0.6 kg

2,3 – 287 ml/min

Page 11: Peristaltic Pumps Series SR 10 · SR 25 Features • Compact design • Quick change of cassette (SR10)/ tubing (SR25) • Infinite tubing possible • Self priming • Safe to run

11®

2025... stock program

Peristaltic Pump SR25 – AdjustableDirect current motor or stepper motor

Physical Data

Direct current motorvoltage: 230 V/50 Hzpower consumption: 7 watts

tubing: Novoprene 4.8 x 1.6 mmpressure height: max. 10 mWCsuction height: max. 8 mWC

Stepper motorvoltage: 230 V/50 Hzpower consumption: 7.5 watts

tubing: Novoprenepressure height: max. 10 mWCsuction height: max. 8 mWC

Flow range1) Speed of the pump Part number with housingml/min (1/min) plastic sheet metal

20 – 80 30 20251636 2025163280 – 300 170 20251885 20251633

Flow range1) Tubing dimension Part number withml/min mm plastic housing

0,21 – 21 N 4,8 x 1,6 mm 20251638

The pump is driven by a direct current motor, which is supplied with230V/50Hz, through an output regulator and a mains supply.

EMC guide lineResistance to jamming according to EN 50082-1 and EN 50082-2Interference suppression according to EN 55011 B

Technical Data

CA

ZU

AUF

1098

7654

321

0

SuctionPressure

Ansicht X Ansicht Y

X Y

130(5.11)

188

(7.3

2)

166.

5 (6

.55)

140

(5.5

1)156 (6.14)

83 (3.26)

29 (1

.14)

105

(4.1

3)

93.5

(3.6

8)

63 (2

.48)

63 (2.48)

2x

0 10

9

8

7

65

4

3

2

1

193 (7.60) 200 (7.87)

12

1 (

4.7

6)

5 (.20)¯

19.5 (.77)

4xBenötigte Wandstärke 3mm

2xGewindebolzen M3x10Art.-Nr.: 80011110

10.1+0.2

44 ±0.1

55 ±0.1

44

±0.1

3.3

25

()

63

.5(

)

63.5( )

14

±0.1

8±0

.1

SR25 – Adjustableplastic housingwith Synchronous motoror Permanentmagnet motor

SR25 – AdjustableDC motorsheet metal housing

bore pattern to fitin a housingfor pumps with a DC motor(and shaded pole motor)

Illu

stra

tion

168

94Ill

ust

ratio

n 1

5345

Illu

stra

tion

126

41

EMC guide lineInterference suppression according to EN 55011 B

1) Note: The indicated values are average. The actual values depend on different parameters like quality and age of tubing, pressure of tubingbeds, pressures proportions, viscosity, etc. Please also have a look on page 2 regarding the recommended runningtimes.

0,21 – 300 ml/min

Page 12: Peristaltic Pumps Series SR 10 · SR 25 Features • Compact design • Quick change of cassette (SR10)/ tubing (SR25) • Infinite tubing possible • Self priming • Safe to run

12

Spare Parts SR25

®

Tubing Connectors Part number

Novoprene 1.6 x 1.6 mm PVC 92025500Novoprene 3.2 x 1.6 mm PVC 92025501Novoprene 4.1 x 1.6 mm PP 92025502Novoprene 4.8 x 1.6 mm PP 92025503Test-set with all tubings 92025856

Novoprene 1.6 x 1.6 mm PVDF 92025552Novoprene 3.2 x 1.6 mm PVDF 92025533Novoprene 4.1 x 1.6 mm PVDF 92025549Novoprene 4.8 x 1.6 mm PVDF 92025563

Silicon 2.0 x 1.0 mm PVC 92025507Silicon 3.0 x 1.0 mm PVC 92025508Silicon 4.0 x 1.5 mm PVC 92025509Silicon 5.0 x 1.5 mm PVC 92025532Test-set with all tubings 92025857

Revolution SR25 SR25 SR25 SR25 AC 12V DC 24V DC Synchr.

1 RPM – – – 920257995 RPM 92025803 – – 92025799

10 RPM 92025804 92025804 92025804 9202579915 RPM – – – 9202579930 RPM 92025803 92025804 92025803 –65 RPM 92025803 92025803 92025803 –80 RPM 92025803 – 92025803 –

170 RPM 92025801 92025806 92025806 –500 RPM 92025801 – – –

Revolution Type Part number

1–15 RPM SR25 Synchr. 920256305–500 RPM SR25 AC/DC 92025625

Part number

29008965

Part number

29020480

Tubing with connectors

Roll carrier

Pump body with clamp

Rolling band

Clamp

Silicon

Novoprene

Viton®

(Acidflex)on request

4 rollers up to 80 RPM on request

Page 13: Peristaltic Pumps Series SR 10 · SR 25 Features • Compact design • Quick change of cassette (SR10)/ tubing (SR25) • Infinite tubing possible • Self priming • Safe to run

13®

Peristaltic Pump SR25-10RPM, with EX-Motor

Peristaltic Pump SR50only for intermittent duty

Supply voltage: 230 V/50 HzMotor in Ex class: Eex m II T3

voltage: 230 V/50 Hzpower consumption: 20 watts

pressure height: 10 mWCsuction height: 8 mWC

A

C

2x

18

(.7

1)

5.5 (.22)¯

70 (2.76)

80 (3.15)

10

1 (

3.9

8)

36.5 (1.44)

5 (.20)¯

63 (2.48)1

5 (

.57

)

84 (3.31)

59 (2.32)

19.5 (.77)

153.5 (6.04)

7 (.28)

Flachstecker fœr

Steckhœlse 6.3-...

DIN 46247

7 (.26)¯

19 (.75)

11 (.43)

64 (2.52)

118

(4.6

5)

102

(4.0

2)

48 (1.89)

40 (1.57)

60.5 (2.38) 31.5 (1.24)

4 (.1

6)¯

35 (1.38)

SR50

SR25 10RPM EX

Illu

stra

tion

171

88Ill

ust

ratio

n 1

5248

Tubing Part numberNovoprene 4.8 x 1.6 mm 20510007

Silicon 5.0 x 1.5 mm 20510009

Tubing Part numberNovoprene 3.2 x 1.6mm 20251857

7 ml/min

55 ml/min

Page 14: Peristaltic Pumps Series SR 10 · SR 25 Features • Compact design • Quick change of cassette (SR10)/ tubing (SR25) • Infinite tubing possible • Self priming • Safe to run

14 ®

Tubing Material

Tube Characteristics Limitations

Novoprene Standard tubing for the SR10/30 and SR10/50 may swell up with oils or oily liquidslong life expectancywide range of applicability

Norprene® Standard tubing for the SR10/30-1, 0N and SR10/100 additives and black pigments may leach outlong life expectancyespecially for alkaline solutions suitable

Pharmed® high quality for Medical, Laboratory and Research use comparatively with Novoprene more expensivehomogeneous structure and therefore comparatively betterchem. resistancelong life expectancysuitable for mineral, vegetable and animal oil

Silicon suitable for polar solvents (with the expection of chlorinated not recommended for strong acids or alkaline solutionaliphatic and aromatizised hydrocarbon) swell up in many organic solutionno detachment of softening agentsvery stable elasticity over a wide temperature range (-30 to 180 °C)

Viton® quite good resistance especially against acids limited service lifelow gas permeability

Tubing Properties

Novoprene Norprene® Pharmed® Silicon Viton®

Acids weak very good good very goodmedium good unsatisfactory very goodstrong not recommended not recommended good

Alkaline weak very good very good good very goodsolution medium good very good unsatisfactory very good

strong not recommended good not recommended good

Hydro- aliphaticcarbons aromatizised not recommended good

halogenated

temperature range -10°C to 130°C -10°C to 130°C -10°C to 130°C -30°C to 180°C 10°C to 200°C

standards/ basic material not recommended USP, class VI physiologically not recommendedphysiological behaviour meets FDA for food, FDA (21 CFR 177.2600) inert for food,

(21 CFR 177.2600) drinks or medicine NSF drinks or medicine

chemical structure thermoplastic thermoplastic thermoplastic high cross linked Fluorcarbonrubberelastomer on PP-Basic elastomer on PP-Basic elastomer on PP-Basic Polysiloxane

with cross linked with anorganic fillersEPDM parts

Choice of tubing depending on flow medium

Page 15: Peristaltic Pumps Series SR 10 · SR 25 Features • Compact design • Quick change of cassette (SR10)/ tubing (SR25) • Infinite tubing possible • Self priming • Safe to run

15®

Chemical Resistance Of Tubing Materials

N = Novoprene Nor = Norprene® Ph = Pharmed® S = Silicon V = Viton®

N Nor Ph S V

Acetaldehyde E A A A CAcetate E B A D CAcetic acid A A A A CAcetic anhydride A B A C CAcetone B C C A CAlcohol B C C A AAluminium chloride E A A D AAluminium sulfate E A A A AAmmonia A A A C CAmmonium (gas) A A A A AAmyl acetate C C E C CAmyl alcohol A B B C AAniline A C E C DAnimal oil B A A D AAntimony salts E A A E DAqua regia C B B C CArsenic salts A A A E ABarium salts E A A C CBenzaldehyde E C B C CBenzic acid A A D E ABenzol C C C C CBenzylalcohol E B B B ABleaching agent B A A A ABoric acid A A A A ABreak liquid E A D A CBromine C A A C AButane E B B C AButanol B B B C BCalcium salts A A A D AChromium salts A A A E ECarbon bisulphide A C A C CChloracetic acid A A D E EChlorine, liquid C C C C DChlorobenzene E C C E CChloroform C C C C AChromic salts A A A C ACyclohexane C C C C ADiesel oil C B B A AEthanol E B E D AEther E D E C DEthylalcohol A B B C AEthylene chlorohydrin E C C C AEthylene glycol E A A A AFluor boric acid E A A E EFluor silicium acid E A D E EFormaldehyde A A A D CFormamide A A D E CFormic acid A A A A CFurfurol E B E E CGlucose A A A A AHydrochloric acid A A A C AHydrocyanic acid E A D C AHydrogen peroxide A A A A AHydrogen sulphide A A A C CIod A A A C A

N Nor Ph S V

Iod solution A A A C AIsoprophyl alcohol C C C A ALactic acid A A A C ALinseed oil A A A A ALithium base grease E A D A AMagnesium chloride solution A A A A AMercury salts A A A C AMethanol A A D A BMethyl ethyl ketone B B B C CMineral oil B B A D ANatrium hydroxide E A A D A(low concentration)Natural gas A A A A ANitroethane E B B C ENitrogene oxide E A A C CNitrous acid 10% B A A C ANitrous acid 30% C B B C ANitrous acid 70% C C C C COil ASTM (116°C) B A A D EOleic acid E B B C DOxalic acid B A A D AOxygen A A A A EPerchloric acid C C C C APerchlorethylene C C E C CPhenol A B E C APhosphoric acid A A A C APhosphorous acid A A A D APhtalic acid E B A A APotassium salts A A A E EPropanol E B B A APyridine C B B C CSalt water A A A A ASoap solutions A A A A BSodium hydroxide 46% E B B D ASodium hypochlorite <5% A A D E ASodium hypochlorite >5% A A D E ASodium salt A A A A ASole E A A E EStearic acid B A A D ESulphurdioxide A A A D ASulphuric acid A A A C A(low concentration)Sulphurous acid A A A C A(low concentration)Sulphurtrioxide E B B D ATannic acid A A E A ATannic extracts E A A E ATetrachloromethane C C C C CTetrahydrofurane C C C C AToluole C C C C CTurpentine C B B C AUric acid A A A D AVegetable fat C B A A AXylene C C C C CZinc chloride B B B B A

The material resistance is influenced by temperature and concentration of the medium.The data has to be seen as indication, and does not guarantee the material properties.

A = small or no effect B = minor or moderate effect C = severe effect D = no reliable data, please test before use E = no available data

Page 16: Peristaltic Pumps Series SR 10 · SR 25 Features • Compact design • Quick change of cassette (SR10)/ tubing (SR25) • Infinite tubing possible • Self priming • Safe to run

Art

.-Nr.:

170

0005

6 0

9/01

ASF THOMAS Industries GmbHSiemensstraße 4 · Gewerbegebiet Nord · D-82178 PuchheimTelephone: +49 (89) 8 09 00-0 · Telefax: +49 (89) 80 83 68e-Mail: [email protected] · http://www.asf-thomas.de

®

QS-System

zertifiziert nach

DIN ISO 9001

TUVPRODUKT SERVICE

The information presented in this materi-al is based on technical data and testresults of nominal units. It is believed tobe accurate and reliable and is offeredas an aid to help in the selection of ASFThomas products. It is the responsibilityof the user to determine the suitability ofthe product for the intended use andthe user assumes all risk and liabilitywhatsoever in connection therewith.ASF Thomas does not warrant, guaran-tee or assume any obligation or liabilityin connection with this information.

Distributors

Australia(also for: New Zealand)Thomas Industries Australia Pty Ltd.10B Wilmette Place Mona Vale, New South WalesAustralia 2103Telephone: +6113 00 36 44 96Telefax: +61 (2) 99 99 2157e-Mail: [email protected]

Austria(also for: Hungary)K-V-D Handelsgesellschaft Wagramer Straße 34A-1220 WienTelephone: +43 (1) 2 69 99 26Telefax: +43 (1) 2 69 99 27e-Mail: [email protected]

BeneluxSanfresh Technical SupplyHoofdweg 80NL-2908 LC Capelle A/ D IjsselTelephone: +31 (10) 4 42 54 00Telefax: +31 (10) 4 42 55 00e-Mail: [email protected]

BrasilGoldsun Importação Exportação Co Ltda.Rua Fernandes Silva, 296,Loja 30, sala 361São Paulo, SP Brasil CEP 03005-010Telephone: +55 (11) 33 26-3710 Telefax: +55 (11) 33 26-19 62e-Mail: [email protected]

CroatiaMetron InstrumentsJosipa Mokrovica 4HR-10090 ZagrebTelephone/fax: +3 85 (1) 3 79 40 25

Czech Republic - SlovakiaMBM Technik S.R.O.Vlcnovska 16CZ-62 800 BrnoTelephone/fax: +4 20 (5) 45 22 30 55

Denmark Reciprotor Engineering A/SKleins Vej 7DK-4930 MariboTelephone: +45 (54) 75 75 45Telefax: +45 (54) 75 95 45e-Mail: [email protected]

FranceSercom S.A.20, Place de la LibertéF-67300 SchiltigheimTelephone: +33 (3) 88 83 66 77Telefax: +33 (3) 88 81 64 14e-Mail: [email protected]

GreeceA. G. Stambolidis & CoMitrodorou 22GR-104 41 AthenTelephone: +30 (1) 5 15 06 65Telefax: +30 (1) 5 15 0810e-Mail: [email protected]

Hong Kong(also for: Asia Pacific)THOMAS Industries Asia Pacific, Ltd.Unit 2503, Metropole SquareNo. 2, On Yiu Street, Siu Lek YuenShatin, New TerritoriesHong KongTelephone: +85 (2) 26 90 35 02Telefax: +85 (2) 27 92 45 98e-Mail: [email protected]

IndiaSawant Pumps Pvt. Ltd.509-512 Bhaveshwar ArcadeL.B.S. MargGhatkopar (West)Mumbai 86Pin Code 400086Telephone: +91(22) 5 00 33 71Telefax: +91(22) 5 00 36 03e-Mail: [email protected]

IsraelDr. E. WurmanP.O.Box 40094IL-90805 Mevaseret Zion Telephone: +9 72 (2) 5 33 56 58Telefax: +9 72 (2) 5 33 52 60e-Mail: [email protected]

ItalyAersistem Impianti S.r.L.Via Buozzi 7/9I-20090 Fizzonasco di Pieve F. (MI)Telephone: +39 (02) 90 72 25 68Telefax: +39 (02) 90 72 34 36e-Mail: [email protected]

JapanThomas Imports Inc. Japan1794 Nippa-cho, Kohoku-kuYokohama-shi, KanagawaJapan 223-0057Telephone: +81 (45) 533 0390Telefax: +81 (45) 533 0391e-Mail: [email protected]

KoreaTHC Tanhay Corp.Business Div.111-84 Hwakok-Dong, Kangseo-KuROC-SeoulTelephone: +82(2) 691-88 88Telefax: +82(2) 696-73 44

PolandGaren Postul. Zeromskiego 14PL-05-510 Konstancin-JeziornaTelephone: +48 (22) 717 37 47Telefax: +48 (22) 717 37 48e-Mail: [email protected]

RussiaCLIMBIP.O.Box 20RUS-Moskow 125422Telephone: +7 (0 95) 9 76 40 55 Telefax: +7 (0 95) 9 76 75 86e-Mail: [email protected]

SingaporeMulti Industrial SuppliesBloc 3015#02-242 Ubi Road 1SGP-1440 Singapore Telephone: +65 (7 43) 83 53/4Telefax: +65 (7 43) 87 64

South AfricaWirsam ScientificP.O.Box 91058ZA-Auckland Park 2006 JHBTelephone: +27 (11) 4 8210 60Telefax: +27 (11) 7 26 60 94e-Mail: [email protected]

Spain(also for: Portugal)Air Control, s.a.Paseo Sarroeta 4E-20014 San SebastianTelephone: +34(9 43) 44 50 80Telefax: +34(9 43) 44 51 53e-Mail: [email protected]

Sweden(also for Norway, Finland, Baltic States)ALDAX ABGötlundagatan 2SE-12471 BandhagenTelephone: +46 (8) 4 47 18 30Telefax: +46 (8) 4 47 18 39e-Mail: [email protected]

Switzerland ASF Thomas Industries (Schweiz) GmbHDruck- und VakuumtechnikFrauenfelder Str. 49CH-8370 Sirnach TGTelephone: +41(71) 9 69 35 00Telefax: +41(71) 9 69 35 01e-Mail: [email protected]

TaiwanThomas IMP. INC.8F/L. No. 272, Section 6Ming Chuan East RoadRC-11231 TaipeiTelephone: +8 86 (2) 26 3111 62Telefax: +8 86 (2) 26 32 70 40

Turkey Setimum Sinai Gerecler ITH. IHR.Mümessillik Ltd.Sarayardi Caddesi Cam. Apt. 80/3TR-81300 Hasanpasa-Kadiköy/IstanbulTelephone: +90 (216) 3 45 50 73Telefax: +90 (216) 3 45 06 96

United KingdomASF THOMAS Ltd.Unit Two, Alton Business Centre Omega Park, AltonGB-Hampshire GU34 2YUTelephone: +44 (14 20) 54 41 84Telefax: +44 (14 20) 54 41 83e-Mail: [email protected]

U. S. A.(also for: Argentina, Bolivia,Caribbean, Central America,Chile, Colombia, Ecuador,Mexico, Paraguay, Peru,Uruguay, Venezuela)Thomas Industries Inc.1419 Illinois Ave.Sheboygan, WI 53082-0029Telephone: +1(9 20) 4 5748 91Telefax: +1(9 20) 4 5142 38e-Mail: [email protected]

RepresentativesGermanyresponsible for:

Postal codes: 01–06, 09–19, 20–25,27–29, 30–33, 37–39, 99Horst WeberWehlbrook 52D-22143 HamburgTelephone: +49 (40) 6 771517Telefax: +49 (40) 6 7717 88e-Mail: [email protected]

Postal codes: 26, 34, 40–49, 50–54,56–59, 66Karl-Heinz HellwigHeinrich-Heine-Straße 4D-42489 WülfrathTelephone: +49 (20 58) 32 81Telefax: +49 (20 58) 7 33 53e-Mail: [email protected]

Postal codes: 35, 36, 55, 60–65,67–69, 7, 88, 89Karl-Heinz StecherUlmenweg 33D-71665 Vaihingen/EnzTelephone: +49 (70 42) 95 20-0Telefax: +49 (70 42) 95 20 20e-Mail: [email protected]

Postal codes: 07, 08, 80–87, 90–98Balthasar LendlExterstraße 59 AD-82194 GröbenzellTelephone: +49 (8142) 59 79 71/2Telefax: +49 (8142) 59 79 70e-Mail: [email protected]