roof underlay | wall lining | façades
Permanent safe
ConstructionsOptimal external sealing for perfect windtightness and insulation
2© pro clima 07.2014 | www.proclima.com
Exterior wind sealing with sarking Exterior Construction
Exterior wind sealing Sarking
Structure of hip and ridge
1
2
Valley detail
1
2
Sticking and overlapping
1
2
Sealing at bargeboard
1 4
Legend
Underlay or sarking membranesSOLITEX MENTO family*) SOLITEX UDSOLITEX PLUS*)
Adhesive tape TESCON VANATESCON No.1
Nail sealing tapeTESCON NAIDEC
Joint adhesiveORCON FORCON CLASSIC
connect technology (integrated self-adhesive zones)
Double-sided adhesive tape DUPLEX
Pipe grommetROFLEX **)
Chimney insulated, double-wall
Protruding lath
Separation lath
Position held by 3-4 mm ofhard fibre or chipboard strip, for example.
Rafter
Counter lath
Info
*) For blown-in insulation, the use of reinforced SOLITEX PLUS or SOLITEX MENTO PLUS is recom-mended
**) Alternatively, pipes can be sealed using short strips of TESCON VANA or TESCON No.1.
1
6 5
Alternative
Sealing at eaves
1
6
Alternative
2
1
8
10
9
11
12
13
3
2
4
5
6
7
3 © pro clima 07.2014 | www.proclima.com
Exterior Construction Exterior wind sealing with sarking
When using pro clima SOLITEX membranes, the entire cavity can be filled with insulation. Complicated and often ineffective replace with: “ventilation between the membrane and the insulation” at the eaves, ridge, valley, hip and additional roof features are thus unnecessary.
Tips
A Allow for cross-drainage above the component
B Ensure that there is water- proof adhesion all around the circumference. • 1st strip on bottom • 2nd + 3rd strip left • Last strip at top
C Leave slack when applying the membrane to allow for relative motion between components.
D Stick with ORCON F or ORCON CLASSIC if necessary
E Alternative: EXTOSEAL MAGOV
F Alternative: EXTOSEAL FINOC
Detail view of nail sealing
1 3
Sealing at dormer window
1
1
1
2
2
Sealing at skylights incl. sheeting channel
A
1
2
2
Retrofit installation of wind sealing/rear ventilation layer
1 D
B
E
1
2 7
Pipe or cable feed-throughs
C A
C
A 1
4
4
Chimney penetration
Please also observe the gene- ral information on sealing to chimneys on page 8 (Interior Construction).
8
13
10 9
1112
F
4© pro clima 07.2014 | www.proclima.com
Exterior wind sealing for facades Exterior Construction
Exterior wind sealingFacade
Standard structure, closed facade
Standard structure, timber wall behind ventilated masonry wall
Window sill in timber construction
Standard structure, partially open facade
Legend
Wall lining membraneSOLITEX FRONTA WA*)
Wall lining membraneSOLITEX FRONTA QUATTRO*)
Wall lining membraneSOLITEX FRONTA HUMIDA*)
Sealing tape TESCON VANA TESCON No.1 TESCON PROFIL
Window sealing tapeCONTEGA EXO**)
Window sealing tapeCONTEGA IQ**)
Joint adhesiveORCON FORCON CLASSICor DUPLEX double-sided adhesive tape
EXTOSEAL ENCORS waterproof adhesive tape
Gap lining
Pre-wall shell
Air layer
Wood fibre insulating panel
Compartment insulation
Vapour retarding and airtightness layer, e.g. wood-based panel
Installation layer
Exterior plastering
Info
*) To improve windproofing, stick SOLITEX membranes to each other and to all adjacent components.
**) Gypsum plasters have very good adhesion on CONTEGA fleece. A bonding bridge – e.g. a reinforcing mortar – must be used for lime and cement plasters.
Facade, window sealing
1
7
2
11
1
10
14
3
2
4
5
7
8
6
15
13
12
11
9
16
1
14 14
2
15 15
13 13
12 1211 11
9
14
3
10 8
15
13
13
1211 12 1416
4 5
Alternative
5
Alternative
6
1
1
2
2
5 © pro clima 07.2014 | www.proclima.com
Exterior Construction Exterior wind sealing for facades
Sealing at windows, at the side of the frame, masonry wall
5 6
6 5
Sealing at windows, on the frame, masonry wall
5
5
4
4
2014
-07
DIG
-248
INTELLO maximum reliability system
INTELLO vapour retarder and air sealing systemMaximum protection against structural damage and mould – also for sophisticated civil engineering structures.Humidity-variable sd value 0.25 to >25 m.
New protection for existing structures – the DASATOP system
The DASATOP sub-and-top refurbishment systemOptimised for roof restoration from the outside.Quick, simple, reliable!
Best possible protection for roofs and walls – the SOLITEX system
Highly permeable roof lining and facade membranes The best quality for reliable structures that are free of structural damage and mould for roofs and walls.
Secure bonding and detail solutions
• All-round adhesive tapes and joint adhesives for interior and exterior use• Plaster sealing tapes• Sealing grommets
You can also visit pro clima ONLINE!
Further information and background information at
Information and orderingYou can obtain information on all pro clima systems, tender information and brochures quickly and simply by contacting our information service:Phone: +49 (0) 62 02 – 27 82.0Fax: +49 (0) 62 02 – 27 82.21eMail: [email protected]
Interior air sealing
Refurbishment and modernisation
Exterior wind sealing
Additional system solutions for
sealing of the building envelope
www.proclima.com
The applications and conditions described here are based on current state-of-the-art research and practical experience. We reserve the right to change the recommended structures and processing methods and to further develop and thus alter the quality of individual products. We would be glad to inform you about the current state of engineering knowledge at the time that your installation is carried out.
www.proclima.com
MOLL bauökologische Produkte GmbHRheintalstraße 35–43D-68723 SchwetzingenGermany
+49 (0) 62 02 - 27 82.0+49 (0) 62 02 - 27 82.21