Upload
phamminh
View
261
Download
5
Embed Size (px)
Citation preview
CheckweigherPharmaceutical
April 2014
2
Bottles/Cans
Standing pouches
Sachets/Sticks
Capsules
6 Lane Checkweigher
Aerosol Inhaler
Checkweigher
Small Bottle
Checkweigher
2 Lane Checkweigher
Case Filling Quality Blister Pack Insert Carton
Filling control and weight check Missing insert check (magnetic ink)
Missing pack check Missing carton check
X-ray
Inspection
System
Case CheckweigherSSV-h Series
Checkweigher
Capsule
Checkweigher Metal Detector
M Series
SSV-h Series
Checkweigher
Seal/Missing tablet check
Overall quality management and control system
Missing blister pack check
Pharmaceutical Checkweigher
L i n e u p
L i n e u p O v e r v i e w
Quicca is a quality management software
that helps you realize real-time line
monitoring and analysis for complete line
optimization. Product traceability and
video monitoring options further enhance
your quality control.
Refer to the Quicca brochure for details.
Multi-Lane Checkweigher
●Capsules
Capsule Checkweigher
●Sachets/Sticks
Multi-Lane Checkweigher
●Standing pouches
2 Lane Pouch Checkweigher
●Bottles/Cans
Small Bottle Checkweigher
Aerosol Inhaler Checkweigher
●Bags/Cartons/Cases
Versatile Checkweighers
●Other
Built-In Multi-Lane Weighing System
4
5
6
7
8
9
10
I n d e x
Aerosol Inhaler Checkweigher
Capsule Checkweigher Small Bottle Checkweigher
Capsules can be individually checkweighed into three classifications
(overweight, proper weight, or lightweight) with a maximum speed of
2000 capsules/min. The automatic cleaning of the weigh table and
periodic zero-setting maintain high accuracy.
A space-saving checkweigher for lines where multiple lanes of
products are inspected with just one unit, such as divided filling
packaging or tube filling lines. The checkweigher allows
centralized control of production records for multiple lanes with
just one indicator.
The weighing systems have stable transfer and high accuracy
measurement for slim, small-diameter bottles including nasal
drops, eye lotions, and cosmetic products that are difficult to
transfer in an upright position.
A star wheel feeds aerosol cans to the weigh table at a constant
speed and with a uniform spacing, achieving high speed weighing
with a maximum accuracy of ± 10 M.
2
3
Bottles/Cans
Standing pouches
Sachets/Sticks
Capsules
6 Lane Checkweigher
Aerosol Inhaler
Checkweigher
Small Bottle
Checkweigher
2 Lane Checkweigher
Case Filling Quality Blister Pack Insert Carton
Filling control and weight check Missing insert check (magnetic ink)
Missing pack check Missing carton check
X-ray
Inspection
System
Case CheckweigherSSV-h Series
Checkweigher
Capsule
Checkweigher Metal Detector
M Series
SSV-h Series
Checkweigher
Seal/Missing tablet check
Overall quality management and control system
Missing blister pack check
Pharmaceutical Checkweigher
L i n e u p
L i n e u p O v e r v i e w
Quicca is a quality management software
that helps you realize real-time line
monitoring and analysis for complete line
optimization. Product traceability and
video monitoring options further enhance
your quality control.
Refer to the Quicca brochure for details.
Multi-Lane Checkweigher
●Capsules
Capsule Checkweigher
●Sachets/Sticks
Multi-Lane Checkweigher
●Standing pouches
2 Lane Pouch Checkweigher
●Bottles/Cans
Small Bottle Checkweigher
Aerosol Inhaler Checkweigher
●Bags/Cartons/Cases
Versatile Checkweighers
●Other
Built-In Multi-Lane Weighing System
4
5
6
7
8
9
10
I n d e x
Aerosol Inhaler Checkweigher
Capsule Checkweigher Small Bottle Checkweigher
Capsules can be individually checkweighed into three classifications
(overweight, proper weight, or lightweight) with a maximum speed of
2000 capsules/min. The automatic cleaning of the weigh table and
periodic zero-setting maintain high accuracy.
A space-saving checkweigher for lines where multiple lanes of
products are inspected with just one unit, such as divided filling
packaging or tube filling lines. The checkweigher allows
centralized control of production records for multiple lanes with
just one indicator.
The weighing systems have stable transfer and high accuracy
measurement for slim, small-diameter bottles including nasal
drops, eye lotions, and cosmetic products that are difficult to
transfer in an upright position.
A star wheel feeds aerosol cans to the weigh table at a constant
speed and with a uniform spacing, achieving high speed weighing
with a maximum accuracy of ± 10 M.
CapsulesSachets/Sticks
Standing pouchesBottles/Cans
Bags/Cartons/CasesOther
4
Pharmaceutical Checkweigher
Capsule Checkweigher
KW9001AP
KW9002AP
CapsulesStanding pouches
Bottles/CansBags/Cartons/Cases
Other Sachets/Sticks
SpecificationsModel KW9001AP KW9002APWeighing range 20 to 1000 MScale interval 0.5 MThroughput 1 Maximum 120,000 capsules/hour Maximum 60,000 capsules/hourAccuracy (3σ) 1 Maximum ± 2 MDisplay ELOperation method Flat panel keyIndication range 1100 MClassification Maximum 20Preset memory 3Product size Capsule No. 00 to 5Power requirements 100 Vac ±10%, single phase, 50/60 Hz, 600 VA 100 Vac ±10%, single phase, 50/60 Hz, 550 VAAir requirements 0.3 to 0.9 MPa, 30R/min [A.N.R.] 0.3 to 0.9 MPa, 15R/min [A.N.R.]Mass 600 O 500 OEnvironmental conditions 15° to 25°C (variation not to exceed 1°C/hour), relative humidity 30% to 70%, non-condensingProtection class IP30Exterior Stainless steel (SUS304)
1: Accuracy and throughput depends on the application and the rejector.Note: The noise level of this system does not exceed 70 dB(A).
KW9001AP KW9002AP
∗Tower Light is an option.
External Dimensions
Control panel
Rejector unit
Air inlet
8 dia. quick coupling
Discharge direction:
Right (optional)NG capsule chute
Hopper (100R)
38
5
67
0
15
024
6
46
53
50°
20°
10
20
18
75
98.6
667
Pass capsule chute width
141.5141.5
112 109
735 29294848
793950
R375
5050100
90 dia.90 dia.
854
Leg spacing
Units: mm
KW9001AP
Control panel
Rejector unit
Air inlet8 dia. quick coupling
Discharge direction:Right (optional)NG capsule chute
Hopper (45R)
385
670
15024
653
50°
20°
1020
1875
98.6
540.5 268 141.5
112109735 2929
4848
793950 5050 100
90 dia.90 dia.
854Leg spacing
Units: mm
KW9002AP
Weighing range: 20 to 1000 MAccuracy (3σ): max. ± 2 MThroughput: max. 120,000 capsules/hour
Weighing range: 20 to 1000 MAccuracy (3σ): max. ± 2 MThroughput: max. 60,000 capsules/hour
(Option)(Option)
5
Pharmaceutical Checkweigher
Multi-Lane Sachet & Stick Checkweigher (6 lanes)
KW6023F□6B*
∗ 3, 4, and 5 lanes available.∗ Weighing range, accuracy, and throughput other than above available.
Model KW6023FF6BKW6023FP6B
Weighing range 0.5 to 60NScale interval 0.005NThroughput 1 Maximum 150 products/min × 6-laneAccuracy (3σ) 1 Maximum ± 0.015NDisplay 10.4-inch color TFT LCDOperation method Touch panelIndication range 60.45NPreset memory Maximum 100Classification 2
Product size 2
Width 20 to 40 mmLength 46 to 230 mmHeight 5 to 60 mm
Belt speed 15 to 60 m/minPower requirements 100 to 120 Vac +10% –15% or 200 to 240 Vac +10% –15%, single phase, 50/60 Hz, 600 VA, rush current 62 A (typ.) (20 ms or less)Rejector 3 IntegratedAir requirements 4 0.5 to 0.9 MPa, 0.3R/min [ A.N.R.] (per lane)Mass Weighing unit: 130 O Indicator: 120 O Environmental conditions 0° to 40°C (variation not to exceed 5°C/h to maintain accuracy), relative humidity 30% to 85%, non-condensingProtection class IP30Exterior KW6023FF6B: Painted KW6023FP6B: Stainless steel (SUS304) (excluding some parts)
1: Accuracy and throughput depends on the application and the rejector.2: The size of the application varies accoding to the rejector. Consult us when the product is transparent or semi-transparent.3: System with no rejector or with rejector having its own feet are available. 4: Maximum air pressure per rejection movement.
Specifications
1: The length is the same if the rejector has its own feet.2: The length of pass heights can be customized for your requirements. The minimum is 400 ± 20 mm.3: The standard length of the cable between the indicator and the weighing unit is 5 m; 10 m is available as an option.
KW6023FF6B(6 lanes)
External Dimensions
740
210
240
350
800
680
400
140
140
380
1490
405
195
1600
9018
85
84
80
(650
)(5
90)
(285)
40 Belt
wid
th
Printer(optional)
Tower light(optional)
730690
650
R655
72620
950610 3403
202
770
Indicator
Indicator
Measuring unit
Flow direction
1
23
M20M20
60 dia. 60 dia.
270Weighing unit46 dia.
roller
18 dia.roller
850
to 1
000
700
to 8
50Li
ne h
eigh
ts
Maint
enan
cesp
ace
Maintenancespace
Units: mm
KW6023FF6BKW6023FP6B
Weighing range: 0.5 to 60NAccuracy (3σ): max. ± 0.015NThroughput: max. 150 products/min x 6 lanes
Sachets/SticksCapsules
Standing pouchesBottles/Cans
Bags/Cartons/CasesOther
6
Pharmaceutical Checkweigher
Standing pouchesCapsules
Bottles/CansBags/Cartons/Cases
Other Sachets/Sticks
2 Lane Pouch Checkweigher
KW6205E□2C*
Model KW6205EF2CKW6205EP2C
Weighing range 2 to 600NScale interval 0.02N/600N, 0.01N/300NThroughput 1 Maximum 400 products/min × 2-laneAccuracy (3σ) 1 Maximum ± 0.02NDisplay 10.4-inch color TFT LCDOperation method Touch panelIndication range 600.9NPreset memory Maximum 100Classification 2 or 3
Product size 2
Width 20 to 160 mmLength 46 to 230 mmHeight 5 to 180 mm
Belt speed 15 to 120 m/minPower requirements 100 to 120 Vac +10% –15% or 200 to 240 Vac +10% –15%, single phase, 50/60 Hz, 500 VA, rush current 62 A (typ.) (20 ms or less)Mass 75 OEnvironmental conditions 0° to 40°C (variation not to exceed 5°C/h to maintain accuracy), relative humidity 30% to 85%, non-condensingProtection class IP30Exterior KW6205EF2C: Painted KW6205EP2C: Stainless steel (SUS304) (excluding some parts)
1: Accuracy and throughput depends on the application and the rejector.2: The size of the application varies accoding to the rejector. Consult us when the product is transparent or semi-transparent.
Specifications
KW6205EP2C(2 lanes)
∗ Weighing range, accuracy, and throughput other than above available.
External Dimensions
880
250
455
175
900
395
47
(300
) Maintenance space
160
Belt w
idth
160
Belt w
idth
Dropout rejector(connection example)
R300
30 65130
2755545
300
270
Flow direction
M2060 dia.
410Leg spacing
190Leg spacing
25 dia.roller
18 dia.roller
18 dia.roller
1370
to 1
470
700
to 8
00Li
ne h
eigh
ts
Units: mm
KW6205EF2CKW6205EP2C
Weighing range: 2 to 600NAccuracy (3σ): max. ± 0.02NThroughput: max. 400 products/min x 2 lanes
∗ The belt pitch in this drawing is the minimum pitch when the checkweigher is connected to a dropout rejector.
∗ The minimum belt pitch of the checkweigher is 150 mm when the belt width is 100 mm. The value depends on the type of a rejector to be connected. Dropout rejector 185 mm or longer Flipper rejector 150 mm to 220 mm Air jet rejector 300 mm or longer
7
Pharmaceutical CheckweigherBottles/Cans
CapsulesStanding pouches
Bags/Cartons/CasesOther
Sachets/Sticks
Small Bottle Checkweigher
KWS9223 type
KWS9223BPHB
Model KWS9223BPHB KWS9223BPHCWeighing range 1 1.2 to 600NScale interval 0.01NThroughput 2 Maximum 200 products/minAccuracy (3σ) 2 Maximum ± 0.02NDisplay 8.5-inch wide color TFT LCDOperation method Touch panel (Start, Stop, and Home are direct push buttons)Indication range 600.9NPreset memory Maximum 200Classification 2 or 3
Product size 3
Width 20 to 40 mmLength 20 to 40 mmHeight 50 to 150 mm
Belt speed 15 to 60 m/minPower requirements 100 to 120 Vac +10% –15% or 200 to 240 Vac +10% –15%, single phase, 50/60 Hz, rush current 40 A (typ.) (40 ms or less)Power consumption 700 VA 550 VAAir requirements 0.5 to 0.9 MPa, 16R/min [A.N.R.] for air jet rejector Air supply not required (Air jet rejector not mounted)Mass 135 O 90 OEnvironmental conditions 0° to 40°C (variation not to exceed 5°C/h to maintain accuracy), relative humidity 30% to 85%, non-condensingProtection class IP30Exterior Stainless steel (SUS304)
1: Maximum weight capacity for KWS9223BPHB air jet rejector is 200N.2: Accuracy and throughput depends on the application and the rejector.3: Varies according to the rejector. Consult us when the product is transparent or semi-transparent.Note: The noise level of this system does not exceed 70 dB(A).Note: Optional compliance with FCC Part 15 available.
Specifications
External Dimensions
35
54
20
94
0
16
5
Le
g s
pa
cin
g
60 dia.M20
270 Windshield
Weighing unit
Flowdirection
Adjustment steering wheel
Indicator
Lin
e h
eig
hts
Air jet rejector
70
0 t
o 8
50
18 dia. roller
40
Air inlet
10 mm (outer dia.) quick coupling
Be
lt w
idth
Printer (optional)
9 273
271171
151
965
1407
NG–BOX
φ4
Leg spacing
43
03
75
69
0
Units: mm
KWS9223BPHB
Flowdirection
151
9 273
171171 370
712
Lin
e h
eig
hts
Indicator
Adjusting handle
270
70
0 t
o 8
50
40
Be
lt w
idth
Printer (optional)
φ4
Leg spacing
43
03
75
35
54
20
94
0
16
5
Le
g s
pa
cin
g
69
0
60 dia.M20
Windshield
Weighing unit
Units: mm
KWS9223BPHC
Weighing range: 1.2 to 600NAccuracy (3σ): max. ± 0.02NThroughput: max. 200 products/min
(Option)(Option)
8
Pharmaceutical Checkweigher
Bottles/CansCapsules
Standing pouchesBags/Cartons/Cases
Other Sachets/Sticks
Aerosol Inhaler Checkweigher Made To Order
KW9627AP00
KW9627AP00
Model KW9627AP00Weighing range 0.5 to 60NScale interval 0.002NThroughput Maximum 150 products/minAccuracy (3σ) 1 Maximum ± 0.01NDisplay 10.4-inch color TFT LCDOperation method Touch panelIndication range 60.450NPreset memory Maximum 100Classification 3Product size
Can size 21.5 / 22.0 / 23.5 / 25.0 mm diameter 2
Height 40 to 80 mmBelt speed 14 m/minPower requirements 3 100 to 115 Vac +10% –15%, single phase, 50/60 Hz, 400 VAAir requirements 0.4 MPa, 20R/min [A.N.R.] (Use dry air.)Mass 150 OEnvironmental conditions 0° to 40°C (variation not to exceed 5°C/h to maintain accuracy), relative humidity 30% to 85%, non-condensingProtection class IP30Exterior Stainless steel (SUS304) (excluding some parts)
1: The accuracy depends on the application.2: Fixed by size, and cannot be shared. Contact our sales representatives for other sizes.3: 200 to 240 Vac is also available as an option.Note: The noise level of this system is 72 dB(A).
Specifications
External Dimensions
820720
100
6275
0
560
Leg
spac
ing
260
Leg s
pacin
g
Air inlet8 mm (outer dia.) quick coupling
410
927902 25
Flow direction
Indicator
550Leg spacing
NG box
1565
to 1
635
815
to 8
85Li
ne h
eigh
ts
Units: mm
KW9627AP00
Weighing range: 0.5 to 60NAccuracy (3σ): max. ± 0.01NThroughput: max. 150 products/min
(Option)(Option)
9
Pharmaceutical Checkweigher
Checkweighers for Bags/Pouches, Cartons, and Cases
Cartons
Bags/Pouches External Dimensions
160
Belt
wid
th 610
495
Leg
spac
ing
400
210
670
Printer(optional)
Indicator
153300
Tower light(optional)
236
18 dia.roller
700
to 8
50Li
ne h
eigh
ts
410Leg spacing
60 dia. M20
105
18 dia.roller
Flow direction
345695
180
Large cases
Units: mm
Model KWS6206BF06 / KWS6206BP06Weighing range 1.2 to 600NScale interval 0.01NThroughput 1 Maximum 320 products/minAccuracy (3σ) 1 Maximum ± 0.015NDisplay 8.5-inch wide color TFT LCDOperation method Touch panel (Start, Stop, and Home are direct push buttons)Indication range 600.9NPreset memory Maximum 200Classification 2 or 3
Product size 2Width 20 to 160 mmLength 46 to 320 mmHeight 5 to 320 mm
Belt speed 15 to 120 m/min
Power requirements 100 to 120 Vac +10% –15% or 200 to 240 Vac +10% –15%, single phase, 50/60 Hz, 130 VA, rush current 20 A (typ.) (20 ms or less)
Mass 60 O
Environmental conditions 0° to 40°C (variation not to exceed 5°C/h to maintain accuracy), relative humidity 30% to 85%, non-condensing
Protection class IP30Exterior F type: Painted P type: Stainless steel (SUS304) (excluding some parts)Standard interfaces USB2.0, 10BASE-T/100BASE-TX Ethernet
Specifications
1: Accuracy and throughput depends on the application and the rejector. 2: Varies according to the rejector. Consult us when the product is transparent or semi transparent. Note: The noise level of this system is 70 dB(A) or lower. Note: Optional compliance with FCC Part 15 available.
External Dimensions
270
670
400
250
Belt
wid
th
67049
5Le
g sp
acin
g
25 dia.roller
25 dia.roller
345695
M2060 dia.
180 410Leg spacing
105
700
to 8
50Li
ne h
eigh
ts
Tower light(optional) Printer
(optional)153300
236
Indicator
Flow direction
Units: mm
Model KWS5412BF12 / KWS5412BP12Weighing range 12 to 3000NScale interval 0.1NThroughput 1 Maximum 320 products/minAccuracy (3σ) 1 Maximum ± 0.2NDisplay 8.5-inch wide color TFT LCDOperation method Touch panel (Start, Stop, and Home are direct push buttons)Indication range 3009NPreset memory Maximum 200Classification 2 or 3
Product size 2Width 20 to 250 mmLength 60 to 310 mmHeight 5 to 310 mm
Belt speed 15 to 120 m/min
Power requirements 100 to 120 Vac +10% –15% or 200 to 240 Vac +10% –15%, single phase, 50/60 Hz, 250 VA, rush current 20 A (typ.) (20 ms or less)
Mass 64 O
Environmental conditions 0° to 40°C (variation not to exceed 5°C/h to maintain accuracy), relative humidity 30% to 85%, non-condensing
Protection class IP30Exterior F type: Painted P type: Stainless steel (SUS304) (excluding some parts)Standard interfaces USB2.0, 10BASE-T/100BASE-TX Ethernet
Specifications
1: Accuracy and throughput depends on the application and the rejector. 2: Varies according to the rejector. Consult us when the product is transparent or semi transparent. Note: The noise level of this system is 70 dB(A) or lower. Note: Optional compliance with FCC Part 15 available.
External Dimensions
Printer(optional)
153300
236
400
Belt
wid
th
820
645
Leg
spac
ing
500Leg spacing
39 dia.roller
650
M20
559560 dia.
700
to 8
50Li
ne h
eigh
ts
Indicator
Tower light(optional)
345
670
475
Flow direction
Units: mm
Model KWS5728BFNN / KWS5728BPNNWeighing range 60 to 25000NScale interval 2NThroughput 1 Maximum 40 products/minAccuracy (3σ) 1 Maximum ± 2NDisplay 8.5-inch wide color TFT LCDOperation method Touch panel (Start, Stop, and Home are direct push buttons)Indication range 25090NPreset memory Maximum 200Classification 2 or 3
Product size 2Width 20 to 450 mmLength 88 to 600 mmHeight 5 to 600 mm
Belt speed 5 to 29 m/min
Power requirements 100 to 120 Vac +10% –15% or 200 to 240 Vac +10% –15%, single phase, 50/60 Hz, 250 VA, rush current 20 A (typ.) (20 ms or less)
Mass 66 O
Environmental conditions 0° to 40°C (variation not to exceed 5°C/h to maintain accuracy), relative humidity 30% to 85%, non-condensing
Protection class IP30Exterior F type: Painted P type: Stainless steel (SUS304) (excluding some parts)Standard interfaces USB2.0, 10BASE-T/100BASE-TX Ethernet
Specifications
1: Accuracy and throughput depends on the application and the rejector. 2: Varies according to the rejector. Consult us when the product is transparent or semi transparent. Note: The noise level of this system is 70 dB(A) or lower. Note: Optional compliance with FCC Part 15 available.
Listed here are just a part of our entire product line. We offer a range of checkweighers to meet different sizes of applications.
(Option)(Option)
(Option)(Option)
(Option)(Option)
Bags/Cartons/CasesCapsules
Standing pouchesBottles/Cans
Other Sachets/Sticks
10
Pharmaceutical Checkweigher
External Dimensions
138
Attachm
ent
spacin
g
420
445
150
324
428 110 290
328
4×φ9
Control unit Measurement unitOperation unit
Operation attachment unit
(optional)Terminal resistance unit
4×φ5
300
Attachmentspacing
Attachmentspacing
Attachmentspacing
65
Attachm
ent spacin
g
3×φ4.3
178
Case to have removed a power supply plug
220
Weighing frame
(optional)
Minimum pitch 33
300 to
Lin
e h
eig
hts
363
563
155
Weighing plate77.5122.5
140
211
350
Units: mm
Built-In Multi-Lane Weighing System
KWS9006AN□□
∗ Designed to be integrated with filling/packing equipment.∗ Refer to the Built-In Multi-Lane Weighing System leaflet for detailed
features.
Operation unit
Control unit
Weighing range: 0.1 to 50NAccuracy (3σ): max. ± 0.002NThroughput: max. 100 products/min (per lane)
Measurement unit
(Option)(Option)Specifications
Model 1 KWS9006AN □□Weighing range 0.1 to 50NScale interval 0.001NThroughput 2 100 products/min per laneAccuracy (3σ) 2 Maximum ± 0.002NDisplay 15-inch color TFT LCDOperation method Touch panel (Start, Stop, Home are direct push bottons)Indication range 50.090NPreset memory Up to 50 Lane Up to 12Power requirements 100 to 120 Vac + 10%–15% or 200 to 240 Vac + 10%–15%, single phase, 50/60 Hz, rush current 12 A (typ.) (20 ms or less)Mass Operation unit: 4 O; Control unit: 6 O; Measurement unit: 1.5 OEnvironmental conditions 0 to 40℃ (variation not to exceed 5 ℃/h to maintain accuracy), relative humidity 30% to 85%, non-condensingProtection class Operation unit: IP50; Control unit: IP20; Measurement unit: IP50Exterior Operation unit: SUS; Control unit: aluminum; Measurement unit: SUSData output USB port (USB2.0), Ethernet interface (10BASE-T, 100BASE-TX)External I/F I/O contact, serial or CC-Link
1: □ indicates the number of lane.2: Depends on the product to be weighed.Note: Strain gauge load cell is also available. Contact our sales representatives. Note: This device complies with part 15 of the FCC Rules.
Note: Dimensions of weighing unit is for 12 lanes.Note: Shapes of weighing table and weighing table stand depend on the specifications. Contact us for detailed dimensions.
Other Capsules
Standing pouchesBottles/Cans
Bags/Cartons/CasesSachets/Sticks
11
Note
KWS9006AN□□
CheckweigherPharmaceutical
April 2014
CAT. NO. K3192-B-1 2014-4 (ddc) Printed in Japan
1001 Cambridge Drive Elk Grove Village, IL 60007-2453
Phone (847)419-XRAY(9729) Fax (847)537-8266
http://www.detectionperfection.com
ISO14001 CERTIFICATE No.JQA-EM0210
ISO 9001 CERTIFICATE No.JQA-0566
Anritsu Industrial Solutions USA Inc.
ANRITSU INDUSTRIAL SOLUTIONS CO., LTD. 2014
In addition to daily inspection, an annual maintenance check should be carried out.
To ensure proper operation, read the Operation Manual before using the machine.
Specifications are subject to change without notice.
No part of this catalog may be reproduced without our permission.
Printed on Recycled Paper
Some products shown in this catalog may not be available in your country or region. Contact our sales representatives for details.