172
1 1 Prof. M. Madhusudhan Rao, E&C Dept., MSRIT UNIT-III Phase Controlled Rectifiers (Line Commutated AC to DC converters)

Phase Controlled-Rectifiers (AC-DC Coverters)

Embed Size (px)

Citation preview

Page 1: Phase Controlled-Rectifiers (AC-DC Coverters)

1Prof. M. Madhusudhan Rao, E&C Dept., MSRIT

UNIT-III

Phase Controlled Rectifiers

(Line Commutated AC to DC converters)

Page 2: Phase Controlled-Rectifiers (AC-DC Coverters)

2Prof. M. Madhusudhan Rao, E&C Dept., MSRIT

• Type of input: Fixed voltage, fixed frequency ac power supply.

• Type of output: Variable dc output voltage• Type of commutation: Natural / AC line

commutation

LineC o m m uta te d

C o nve rte r

+

-

DC O utp utV0 (d c )

ACInp ut

Vo lta g e

Page 3: Phase Controlled-Rectifiers (AC-DC Coverters)

3Prof. M. Madhusudhan Rao, E&C Dept., MSRIT

Different types of Line Commutated Converters

• AC to DC Converters (Phase controlled rectifiers)

• AC to AC converters (AC voltage controllers)• AC to AC converters (Cyclo converters) at low

output frequency.

Page 4: Phase Controlled-Rectifiers (AC-DC Coverters)

4Prof. M. Madhusudhan Rao, E&C Dept., MSRIT

Differences Between Diode Rectifiers

& Phase Controlled Rectifiers

Page 5: Phase Controlled-Rectifiers (AC-DC Coverters)

5Prof. M. Madhusudhan Rao, E&C Dept., MSRIT

• The diode rectifiers are referred to as uncontrolled rectifiers .

• The diode rectifiers give a fixed dc output voltage .

• Each diode conducts for one half cycle.• Diode conduction angle = 1800 or radians. • We can not control the dc output voltage or the

average dc load current in a diode rectifier circuit.

Page 6: Phase Controlled-Rectifiers (AC-DC Coverters)

6Prof. M. Madhusudhan Rao, E&C Dept., MSRIT

Single phase half wave diode rectifier gives an

Average dc output voltage

Single phase full wave diode rectifier gives an

2Average dc output voltage

mO dc

mO dc

VV

VV

Page 7: Phase Controlled-Rectifiers (AC-DC Coverters)

7Prof. M. Madhusudhan Rao, E&C Dept., MSRIT

Applications ofPhase Controlled Rectifiers

• DC motor control in steel mills, paper and textile mills employing dc motor drives.

• AC fed traction system using dc traction motor.• Electro-chemical and electro-metallurgical

processes.• Magnet power supplies.• Portable hand tool drives.

Page 8: Phase Controlled-Rectifiers (AC-DC Coverters)

8Prof. M. Madhusudhan Rao, E&C Dept., MSRIT

Classification ofPhase Controlled Rectifiers

• Single Phase Controlled Rectifiers. • Three Phase Controlled Rectifiers.

Page 9: Phase Controlled-Rectifiers (AC-DC Coverters)

9Prof. M. Madhusudhan Rao, E&C Dept., MSRIT

Different types of Single Phase Controlled Rectifiers.• Half wave controlled rectifiers. • Full wave controlled rectifiers.

Using a center tapped transformer. Full wave bridge circuit.

Semi converter.Full converter.

Page 10: Phase Controlled-Rectifiers (AC-DC Coverters)

10Prof. M. Madhusudhan Rao, E&C Dept., MSRIT

Different Types of Three Phase Controlled Rectifiers• Half wave controlled rectifiers.• Full wave controlled rectifiers.

•Semi converter (half controlled bridge converter).

•Full converter (fully controlled bridge converter).

Page 11: Phase Controlled-Rectifiers (AC-DC Coverters)

11Prof. M. Madhusudhan Rao, E&C Dept., MSRIT

Principle of Phase Controlled Rectifier Operation

Page 12: Phase Controlled-Rectifiers (AC-DC Coverters)

12Prof. M. Madhusudhan Rao, E&C Dept., MSRIT

Single Phase Half-Wave Thyristor Converter with a Resistive Load

Page 13: Phase Controlled-Rectifiers (AC-DC Coverters)

13Prof. M. Madhusudhan Rao, E&C Dept., MSRIT

Supply Voltage

Output Voltage

Output (load)

Current

Page 14: Phase Controlled-Rectifiers (AC-DC Coverters)

14Prof. M. Madhusudhan Rao, E&C Dept., MSRIT

Supply Voltage

Thyristor Voltage

Page 15: Phase Controlled-Rectifiers (AC-DC Coverters)

15Prof. M. Madhusudhan Rao, E&C Dept., MSRIT

Equations

sin i/p ac supply voltage

max. value of i/p ac supply voltage

RMS value of i/p ac supply voltage2

output voltage across the load

s m

m

mS

O L

v V t

V

VV

v v

Page 16: Phase Controlled-Rectifiers (AC-DC Coverters)

16Prof. M. Madhusudhan Rao, E&C Dept., MSRIT

When the thyristor is triggered at

sin ; to

Load current; to

sinsin ; to

Where max. value of load current

O L m

OO L

mO L m

mm

t

v v V t t

vi i t

RV t

i i I t tRV

IR

Page 17: Phase Controlled-Rectifiers (AC-DC Coverters)

17Prof. M. Madhusudhan Rao, E&C Dept., MSRIT

To Derive an Expression for the Average (DC)

Output Voltage Across The Load

Page 18: Phase Controlled-Rectifiers (AC-DC Coverters)

18Prof. M. Madhusudhan Rao, E&C Dept., MSRIT

2

0

1. ;

2

sin

1sin .

2

1sin .

2

dc OO dc

O m

dc mO dc

mO dc

V V v d t

v V t for t to

V V V t d t

V V t d t

Page 19: Phase Controlled-Rectifiers (AC-DC Coverters)

19

sin .2

cos2

cos cos ; cos 12

1 cos ; 22

mO dc

mO dc

mO dc

mm SO dc

VV t d t

VV t

VV

VV V V

Page 20: Phase Controlled-Rectifiers (AC-DC Coverters)

20Prof. M. Madhusudhan Rao, E&C Dept., MSRIT

max

max

Maximum average (dc) o/p

voltage is obtained when 0

and the maximum dc output voltage

1 cos0 ; cos 0 12

mdmdc

mdmdc

VV V

VV V

Page 21: Phase Controlled-Rectifiers (AC-DC Coverters)

21Prof. M. Madhusudhan Rao, E&C Dept., MSRIT

0

1 cos ; 22

The average dc output voltage can be varied

by varying the trigger angle from 0 to a

maximum of 180 radians

We can plot the control characteristic

v by using the eq

mm SO dc

O dc

VV V V

V s

uation for O dcV

Page 22: Phase Controlled-Rectifiers (AC-DC Coverters)

22Prof. M. Madhusudhan Rao, E&C Dept., MSRIT

Control Characteristic of

Single Phase Half Wave Phase Controlled Rectifier

with Resistive Load

Page 23: Phase Controlled-Rectifiers (AC-DC Coverters)

23Prof. M. Madhusudhan Rao, E&C Dept., MSRIT

The average dc output voltage is given by the

expression

1 cos2

We can obtain the control characteristic by

plotting the expression for the dc output

voltage as a function of trigger angle

mO dc

VV

Page 24: Phase Controlled-Rectifiers (AC-DC Coverters)

24Prof. M. Madhusudhan Rao, E&C Dept., MSRIT

Page 25: Phase Controlled-Rectifiers (AC-DC Coverters)

25Prof. M. Madhusudhan Rao, E&C Dept., MSRIT

Control CharacteristicVO (dc)

Tr igger angle in degrees

0 60 120 180

Vdm

0.2 V dm

0.6Vdm

Page 26: Phase Controlled-Rectifiers (AC-DC Coverters)

26Prof. M. Madhusudhan Rao, E&C Dept., MSRIT

Normalizing the dc output

voltage with respect to , the

Normalized output voltage

1 cos2

11 cos

2

dm

m

dcn

mdm

dcn dcn

dm

V

VV

VVV

VV V

V

Page 27: Phase Controlled-Rectifiers (AC-DC Coverters)

27Prof. M. Madhusudhan Rao, E&C Dept., MSRIT

To Derive An Expression for the

RMS Value of Output Voltage of a

Single Phase Half Wave Controlled Rectifier With Resistive Load

Page 28: Phase Controlled-Rectifiers (AC-DC Coverters)

28Prof. M. Madhusudhan Rao, E&C Dept., MSRIT

22

0

1

22 2

The RMS output voltage is given by

1.

2

Output voltage sin ; for to

1sin .

2

OO RMS

O m

mO RMS

V v d t

v V t t

V V t d t

Page 29: Phase Controlled-Rectifiers (AC-DC Coverters)

29Prof. M. Madhusudhan Rao, E&C Dept., MSRIT

2

1

22

12 2

12 2

1 cos 2By substituting sin , we get

2

1 cos 21.

2 2

1 cos 2 .4

cos 2 .4

mO RMS

mO RMS

mO RMS

tt

tV V d t

VV t d t

VV d t t d t

Page 30: Phase Controlled-Rectifiers (AC-DC Coverters)

30

1

2

1

2

1

2

1

2

1 sin 222

sin 2 sin 21;sin2 0

2 2

1 sin 2

2 2

sin 2

22

mO RMS

mO RMS

mO RMS

mO RMS

V tV t

VV

VV

VV

Page 31: Phase Controlled-Rectifiers (AC-DC Coverters)

31Prof. M. Madhusudhan Rao, E&C Dept., MSRIT

Performance Parameters Of

Phase Controlled Rectifiers

Page 32: Phase Controlled-Rectifiers (AC-DC Coverters)

32Prof. M. Madhusudhan Rao, E&C Dept., MSRIT

Output dc power (avg. or dc o/p

power delivered to the load)

; . .,

Where

avg./ dc value of o/p voltage.

avg./dc value of o/p current

dc dc dcO dc O dc O dc

dcO dc

dcO dc

P V I i e P V I

V V

I I

Page 33: Phase Controlled-Rectifiers (AC-DC Coverters)

33Prof. M. Madhusudhan Rao, E&C Dept., MSRIT

Output ac power

Efficiency of Rectification (Rectification Ratio)

Efficiency ; % Efficiency 100

The o/p voltage consists of two components

The dc component

The ac

O ac O RMS O RMS

O dc O dc

O ac O ac

O dc

P V I

P P

P P

V

/ripple component ac r rmsV V

Page 34: Phase Controlled-Rectifiers (AC-DC Coverters)

34Prof. M. Madhusudhan Rao, E&C Dept., MSRIT

2 2

2 2

The total RMS value of output voltage is given by

Form Factor (FF) which is a measure of the

shape of the output voltage is given by

RMS output l

O RMS O dc r rms

ac r rms O RMS O dc

O RMS

O dc

V V V

V V V V

VFF

V

oad voltage

DC load output load voltage

Page 35: Phase Controlled-Rectifiers (AC-DC Coverters)

35Prof. M. Madhusudhan Rao, E&C Dept., MSRIT

22 2

2

The Ripple Factor (RF) w.r.t. o/p voltage w/f

1

1

r rms acv

dcO dc

O RMS O dc O RMS

v

O dc O dc

v

V Vr RF

V V

V V Vr

V V

r FF

Page 36: Phase Controlled-Rectifiers (AC-DC Coverters)

36Prof. M. Madhusudhan Rao, E&C Dept., MSRIT

2 2

max min

max min

Current Ripple Factor

Where

peak to peak ac ripple output voltage

peak to peak ac ripple load current

r rms aci

dcO dc

acr rms O RMS O dc

r pp

r pp O O

r pp

r pp O O

I Ir

I I

I I I I

V

V V V

I

I I I

Page 37: Phase Controlled-Rectifiers (AC-DC Coverters)

37Prof. M. Madhusudhan Rao, E&C Dept., MSRIT

Transformer Utilization Factor (TUF)

Where

RMS supply (secondary) voltage

RMS supply (secondary) current

O dc

S S

S

S

PTUF

V I

V

I

Page 38: Phase Controlled-Rectifiers (AC-DC Coverters)

38Prof. M. Madhusudhan Rao, E&C Dept., MSRIT

Page 39: Phase Controlled-Rectifiers (AC-DC Coverters)

39Prof. M. Madhusudhan Rao, E&C Dept., MSRIT

1

Where

Supply voltage at the transformer secondary side

i/p supply current

(transformer secondary winding current)

Fundamental component of the i/p supply current

Peak value of the input s

S

S

S

P

v

i

i

I

upply current

Phase angle difference between (sine wave

components) the fundamental components of i/p

supply current & the input supply voltage.

Page 40: Phase Controlled-Rectifiers (AC-DC Coverters)

40Prof. M. Madhusudhan Rao, E&C Dept., MSRIT

1

Displacement angle (phase angle)

For an RL load

Displacement angle = Load impedance angle

tan for an RL load

Displacement Factor (DF) or

Fundamental Power Factor

L

R

DF Cos

Page 41: Phase Controlled-Rectifiers (AC-DC Coverters)

41Prof. M. Madhusudhan Rao, E&C Dept., MSRIT

112 22 2 2

121 1

1

Harmonic Factor (HF) or

Total Harmonic Distortion Factor ; THD

1

Where

RMS value of input supply current.

RMS value of fundamental component of

the i

S S S

S S

S

S

I I IHF

I I

I

I

/p supply current.

Page 42: Phase Controlled-Rectifiers (AC-DC Coverters)

42Prof. M. Madhusudhan Rao, E&C Dept., MSRIT

1 1

Input Power Factor (PF)

cos cos

The Crest Factor (CF)

Peak input supply c

For an Ide

urrent

RMS input supply current

1; 100% ;

al Controlled Rectifier

0 ; 1;

S S S

S S S

S peak

S

ac r rms

V I IPF

V I I

ICF

I

FF V V TUF

R

0 ; 0; 1vF r HF THD PF DPF

Page 43: Phase Controlled-Rectifiers (AC-DC Coverters)

43Prof. M. Madhusudhan Rao, E&C Dept., MSRIT

Single Phase Half Wave Controlled Rectifier

With An

RL Load

Page 44: Phase Controlled-Rectifiers (AC-DC Coverters)

44Prof. M. Madhusudhan Rao, E&C Dept., MSRIT

Page 45: Phase Controlled-Rectifiers (AC-DC Coverters)

45Prof. M. Madhusudhan Rao, E&C Dept., MSRIT

Input Supply Voltage (Vs)&

Thyristor (Output) Current Waveforms

Page 46: Phase Controlled-Rectifiers (AC-DC Coverters)

46Prof. M. Madhusudhan Rao, E&C Dept., MSRIT

Page 47: Phase Controlled-Rectifiers (AC-DC Coverters)

47Prof. M. Madhusudhan Rao, E&C Dept., MSRIT

Output (Load) Voltage Waveform

Page 48: Phase Controlled-Rectifiers (AC-DC Coverters)

48Prof. M. Madhusudhan Rao, E&C Dept., MSRIT

1

To Derive An Expression For

The Output

(Load) Current, During to

When Thyristor Conducts

t

T

Page 49: Phase Controlled-Rectifiers (AC-DC Coverters)

49Prof. M. Madhusudhan Rao, E&C Dept., MSRIT

1

1

Assuming is triggered ,

we can write the equation,

sin ;

General expression for the output current,

sin

OO m

tm

O

T t

diL Ri V t t

dt

Vi t A e

Z

Page 50: Phase Controlled-Rectifiers (AC-DC Coverters)

50Prof. M. Madhusudhan Rao, E&C Dept., MSRIT

22

1

1

2 maximum supply voltage.

=Load impedance.

tan Load impedance angle.

Load circuit time constant.

general expression for the output load current

sin

m S

Rt

m LO

V V

Z R L

L

R

L

R

Vi t A e

Z

Page 51: Phase Controlled-Rectifiers (AC-DC Coverters)

51Prof. M. Madhusudhan Rao, E&C Dept., MSRIT

1

1

1

1

1

Constant is calculated from

initial condition 0 at ; t=

0 sin

sin

We get the value of constant as

sin

O

Rt

m LO

Rt

mL

RmL

A

i t

Vi A e

Z

VA e

ZA

VA e

Z

Page 52: Phase Controlled-Rectifiers (AC-DC Coverters)

52Prof. M. Madhusudhan Rao, E&C Dept., MSRIT

1Substituting the value of constant in the

general expression for

sin sin

we obtain the final expression for the

inductive load current

sin sin

O

Rt

m mLO

Rt

m LO

A

i

V Vi t e

Z Z

Vi t e

Z

;

Where t

Page 53: Phase Controlled-Rectifiers (AC-DC Coverters)

53Prof. M. Madhusudhan Rao, E&C Dept., MSRIT

Extinction angle can be calculated by using

the condition that 0

sin sin 0

sin sin

can be calculated by solving the above eqn.

O

Rt

m LO

R

L

i at t

Vi t e

Z

e

Page 54: Phase Controlled-Rectifiers (AC-DC Coverters)

54Prof. M. Madhusudhan Rao, E&C Dept., MSRIT

To Derive An Expression For

Average (DC) Load Voltage of a Single Half Wave Controlled

Rectifier withRL Load

Page 55: Phase Controlled-Rectifiers (AC-DC Coverters)

55Prof. M. Madhusudhan Rao, E&C Dept., MSRIT

2

0

2

0

1.

2

1. . .

2

0 for 0 to & for to 2

1. ;

2

sin for to

L OO dc

L O O OO dc

O

L OO dc

O m

V V v d t

V V v d t v d t v d t

v t t

V V v d t

v V t t

Page 56: Phase Controlled-Rectifiers (AC-DC Coverters)

56Prof. M. Madhusudhan Rao, E&C Dept., MSRIT

1sin .

2

cos2

cos cos2

cos cos2

L mO dc

mLO dc

mLO dc

mLO dc

V V V t d t

VV V t

VV V

VV V

Page 57: Phase Controlled-Rectifiers (AC-DC Coverters)

57Prof. M. Madhusudhan Rao, E&C Dept., MSRIT

During the period to the

instantaneous o/p voltage is negative

reduces the average or the dc output

vo

and

this

when compared to a purely

resist

ltage

ive load.

t

Effect of Load Inductance on the Output

Page 58: Phase Controlled-Rectifiers (AC-DC Coverters)

58Prof. M. Madhusudhan Rao, E&C Dept., MSRIT

Average DC Load Current

cos cos

2O dc m

O dc L AvgL L

V VI I

R R

Page 59: Phase Controlled-Rectifiers (AC-DC Coverters)

59Prof. M. Madhusudhan Rao, E&C Dept., MSRIT

Single Phase Half Wave Controlled Rectifier

With RL Load &

Free Wheeling Diode

Page 60: Phase Controlled-Rectifiers (AC-DC Coverters)

60Prof. M. Madhusudhan Rao, E&C Dept., MSRIT

V 0

i0T

R

L

V s ~+

+

FW D

Page 61: Phase Controlled-Rectifiers (AC-DC Coverters)

61Prof. M. Madhusudhan Rao, E&C Dept., MSRIT

0

0

0

0

vS

iG

vO

t

t

t

t

Supp ly vo ltage

Load curren t

Load vo ltage

t=

2

G ate pu lses

iO

Page 62: Phase Controlled-Rectifiers (AC-DC Coverters)

62Prof. M. Madhusudhan Rao, E&C Dept., MSRIT

The followi

The average

ng points a

output voltage

1 cos which is the same as that 2

of a purely resistive load.

For low value of inductance, the load current

tends to become dis

re to be noted

cont

mdc

VV

inuous.

Page 63: Phase Controlled-Rectifiers (AC-DC Coverters)

63Prof. M. Madhusudhan Rao, E&C Dept., MSRIT

During the period to

the load current is carried by the SCR.

During the period to load current is

carried by the free wheeling diode.

The value of depends on the value of

R and L and the forwa

rd resistance

of the FWD.

Page 64: Phase Controlled-Rectifiers (AC-DC Coverters)

64Prof. M. Madhusudhan Rao, E&C Dept., MSRIT

For Large Load Inductancethe load current does not reach zero, & we obtain continuous load current

0 t

2

t1

i0

S C R S C RF W D F W D

t3t2 t4

Page 65: Phase Controlled-Rectifiers (AC-DC Coverters)

65Prof. M. Madhusudhan Rao, E&C Dept., MSRIT

Single Phase Half Wave Controlled Rectifier With

A General Load

Page 66: Phase Controlled-Rectifiers (AC-DC Coverters)

66Prof. M. Madhusudhan Rao, E&C Dept., MSRIT

R

vS~+

L

E+

vO

iO

Page 67: Phase Controlled-Rectifiers (AC-DC Coverters)

67Prof. M. Madhusudhan Rao, E&C Dept., MSRIT

1sin

For trigger angle ,

the Thyristor conducts from to

For trigger angle ,

the Thyristor conducts from to

m

E

V

t

t

Page 68: Phase Controlled-Rectifiers (AC-DC Coverters)

68Prof. M. Madhusudhan Rao, E&C Dept., MSRIT

0

0

iO

t

t

L o a d c u rr en t

E

v O

L o a d v o lt a g e

V m

I m

Page 69: Phase Controlled-Rectifiers (AC-DC Coverters)

69Prof. M. Madhusudhan Rao, E&C Dept., MSRIT

Equations

sin Input supply voltage.

sin o/p load voltage

for to .

for 0 to &

for to 2 .

S m

O m

O

v V t

v V t

t

v E t

t

Page 70: Phase Controlled-Rectifiers (AC-DC Coverters)

70Prof. M. Madhusudhan Rao, E&C Dept., MSRIT

Expression for the Load CurrentWhen the thyristor is triggered at a delay angle of

, the eqn. for the circuit can b

sin +E

e written as

The general expression for the output load

current can be writte

;

n

Om O

diV t i R L t

dt

s

as

int

mO

V Ei t Ae

Z R

Page 71: Phase Controlled-Rectifiers (AC-DC Coverters)

71Prof. M. Madhusudhan Rao, E&C Dept., MSRIT

22

1

Where

= Load Impedance.

tan Load impedance angle.

Load circuit time constant.

The general expression for the o/p current can

be written as sinR

tm L

O

V Ei t Ae

Z

Z R

L

R

L

R

R

L

Page 72: Phase Controlled-Rectifiers (AC-DC Coverters)

72Prof. M. Madhusudhan Rao, E&C Dept., MSRIT

To find the value of the constant

'A' apply the initial conditions at ,

load current 0, Equating the general

expression for the load current to zero at

, we get

0 sinR

mO

O

L

t

i

t

V Ei Ae

Z R

Page 73: Phase Controlled-Rectifiers (AC-DC Coverters)

73Prof. M. Madhusudhan Rao, E&C Dept., MSRIT

We obtain the value of constant 'A' as

Substituting the value of the constant 'A' in the

expression for the load current; we get the

complete expression for the output load c

si

ur

nR

m LVE

A eR Z

sin

rent

in

s

asR

tm m L

O

V VE Ei t e

Z R R Z

Page 74: Phase Controlled-Rectifiers (AC-DC Coverters)

74Prof. M. Madhusudhan Rao, E&C Dept., MSRIT

To Derive An

Expression For The Average Or

DC Load Voltage

Page 75: Phase Controlled-Rectifiers (AC-DC Coverters)

75

2

0

2

0

2

0

sin Output load voltage

1.

2

1.

for 0 to & for to 2

for

. .

to

2

1. sin .

2

O

OO dc

O O OO d

m

m

c

O dc

O

V v d t

V v d t v d t v d t

V E d t V t E d t

v V t

v E t t

t

Page 76: Phase Controlled-Rectifiers (AC-DC Coverters)

76Prof. M. Madhusudhan Rao, E&C Dept., MSRIT

2

0

1cos

2

10 cos cos 2

2

cos cos 22 2

2cos cos

2 2

mO dc

mO dc

mO dc

mO dc

V E t V t E t

V E V E

V EV

VV E

Page 77: Phase Controlled-Rectifiers (AC-DC Coverters)

77Prof. M. Madhusudhan Rao, E&C Dept., MSRIT

2

2

0

Conduction angle of thyristor

RMS Output Voltage can be calculated

by using the expres

1.

sion

2 OO RMSV v d t

Page 78: Phase Controlled-Rectifiers (AC-DC Coverters)

78Prof. M. Madhusudhan Rao, E&C Dept., MSRIT

Single Phase Full Wave Controlled Rectifier

Using A Center Tapped Transformer

Page 79: Phase Controlled-Rectifiers (AC-DC Coverters)

79Prof. M. Madhusudhan Rao, E&C Dept., MSRIT

ACSupply

O

A

B

T 1

T2

R L

vO

+

Page 80: Phase Controlled-Rectifiers (AC-DC Coverters)

80Prof. M. Madhusudhan Rao, E&C Dept., MSRIT

Discontinuous Load Current Operation

without FWDfor

Page 81: Phase Controlled-Rectifiers (AC-DC Coverters)

81Prof. M. Madhusudhan Rao, E&C Dept., MSRIT

vOV m

0

( ) ( )

iO

t

t0

Page 82: Phase Controlled-Rectifiers (AC-DC Coverters)

82Prof. M. Madhusudhan Rao, E&C Dept., MSRIT

1

To Derive An Expression For

The Output

(Load) Current, During to

When Thyristor Conducts

t

T

Page 83: Phase Controlled-Rectifiers (AC-DC Coverters)

83Prof. M. Madhusudhan Rao, E&C Dept., MSRIT

1

1

Assuming is triggered ,

we can write the equation,

sin ;

General expression for the output current,

sin

OO m

tm

O

T t

diL Ri V t t

dt

Vi t A e

Z

Page 84: Phase Controlled-Rectifiers (AC-DC Coverters)

84

22

1

1

2 maximum supply voltage.

=Load impedance.

tan Load impedance angle.

Load circuit time constant.

general expression for the output load current

sin

m S

Rt

m LO

V V

Z R L

L

R

L

R

Vi t A e

Z

Page 85: Phase Controlled-Rectifiers (AC-DC Coverters)

85Prof. M. Madhusudhan Rao, E&C Dept., MSRIT

1

1

1

1

1

Constant is calculated from

initial condition 0 at ; t=

0 sin

sin

We get the value of constant as

sin

O

Rt

m LO

Rt

mL

RmL

A

i t

Vi A e

Z

VA e

ZA

VA e

Z

Page 86: Phase Controlled-Rectifiers (AC-DC Coverters)

86Prof. M. Madhusudhan Rao, E&C Dept., MSRIT

1Substituting the value of constant in the

general expression for

sin sin

we obtain the final expression for the

inductive load current

sin sin

O

Rt

m mLO

Rt

m LO

A

i

V Vi t e

Z Z

Vi t e

Z

;

Where t

Page 87: Phase Controlled-Rectifiers (AC-DC Coverters)

87Prof. M. Madhusudhan Rao, E&C Dept., MSRIT

Extinction angle can be calculated by using

the condition that 0

sin sin 0

sin sin

can be calculated by solving the above eqn.

O

Rt

m LO

R

L

i at t

Vi t e

Z

e

Page 88: Phase Controlled-Rectifiers (AC-DC Coverters)

88Prof. M. Madhusudhan Rao, E&C Dept., MSRIT

To Derive An Expression For The DC Output Voltage Of

A Single Phase Full Wave Controlled Rectifier With RL Load

(Without FWD)

Page 89: Phase Controlled-Rectifiers (AC-DC Coverters)

89Prof. M. Madhusudhan Rao, E&C Dept., MSRIT

vOV m

0

( ) ( )

iO

t

t0

Page 90: Phase Controlled-Rectifiers (AC-DC Coverters)

90Prof. M. Madhusudhan Rao, E&C Dept., MSRIT

1.

1sin .

cos

cos cos

dc OO dct

dc mO dc

mdcO dc

mdcO dc

V V v d t

V V V t d t

VV V t

VV V

Page 91: Phase Controlled-Rectifiers (AC-DC Coverters)

91Prof. M. Madhusudhan Rao, E&C Dept., MSRIT

When the load inductance is negligible i.e., 0

Extinction angle radians

Hence the average or dc output voltage for R load

cos cos

cos 1

1 cos ; for R load, when

mO dc

mO dc

mO dc

L

VV

VV

VV

Page 92: Phase Controlled-Rectifiers (AC-DC Coverters)

92Prof. M. Madhusudhan Rao, E&C Dept., MSRIT

2 2

To calculate the RMS output voltage we use

the expression

1sin .mO RMSV V t d t

Page 93: Phase Controlled-Rectifiers (AC-DC Coverters)

93Prof. M. Madhusudhan Rao, E&C Dept., MSRIT

Discontinuous Load Current Operation with FWD

Page 94: Phase Controlled-Rectifiers (AC-DC Coverters)

94

vOV m

0

( ) ( )

iO

t

t0

Page 95: Phase Controlled-Rectifiers (AC-DC Coverters)

95Prof. M. Madhusudhan Rao, E&C Dept., MSRIT

2

2

1

1

Thyristor is trigger

Thyristor is triggered at ;

conducts from to

FWD conducts from to &

0 during discontinuous loa

ed at ;

conducts from t

d current.

o 2

O

T t

T

T t

t

T t

t

v

Page 96: Phase Controlled-Rectifiers (AC-DC Coverters)

96Prof. M. Madhusudhan Rao, E&C Dept., MSRIT

To Derive an Expression For The

DC Output Voltage For A

Single Phase Full Wave Controlled Rectifier

With RL Load & FWD

Page 97: Phase Controlled-Rectifiers (AC-DC Coverters)

97

0

1.

1sin .

cos

cos cos ; cos 1

1 cos

dc OO dct

dc mO dc

mdcO dc

mdcO dc

mdcO dc

V V v d t

V V V t d t

VV V t

VV V

VV V

Page 98: Phase Controlled-Rectifiers (AC-DC Coverters)

98Prof. M. Madhusudhan Rao, E&C Dept., MSRIT

• The load current is discontinuous for low values of load inductance and for large values of trigger angles.

• For large values of load inductance the load current flows continuously without falling to zero.

• Generally the load current is continuous for large load inductance and for low trigger angles.

Page 99: Phase Controlled-Rectifiers (AC-DC Coverters)

99Prof. M. Madhusudhan Rao, E&C Dept., MSRIT

Continuous Load Current Operation

(Without FWD)

Page 100: Phase Controlled-Rectifiers (AC-DC Coverters)

100Prof. M. Madhusudhan Rao, E&C Dept., MSRIT

vOV m

0

( )

iO

t

t0

( )

Page 101: Phase Controlled-Rectifiers (AC-DC Coverters)

101Prof. M. Madhusudhan Rao, E&C Dept., MSRIT

To Derive An Expression For

Average / DC Output VoltageOf

Single Phase Full Wave Controlled Rectifier For Continuous Current

Operation without FWD

Page 102: Phase Controlled-Rectifiers (AC-DC Coverters)

102Prof. M. Madhusudhan Rao, E&C Dept., MSRIT

vOV m

0

( )

iO

t

t0

( )

Page 103: Phase Controlled-Rectifiers (AC-DC Coverters)

103Prof. M. Madhusudhan Rao, E&C Dept., MSRIT

1.

1sin .

cos

dc OO dct

dc mO dc

mdcO dc

V V v d t

V V V t d t

VV V t

Page 104: Phase Controlled-Rectifiers (AC-DC Coverters)

104Prof. M. Madhusudhan Rao, E&C Dept., MSRIT

cos cos ;

cos cos

cos cos

2cos

dcO dc

m

mdcO dc

mdcO dc

V V

V

VV V

VV V

Page 105: Phase Controlled-Rectifiers (AC-DC Coverters)

105Prof. M. Madhusudhan Rao, E&C Dept., MSRIT

• By plotting VO(dc) versus , we obtain the control characteristic of a single phase full wave controlled rectifier with RL load for continuous load current operation without FWD

Page 106: Phase Controlled-Rectifiers (AC-DC Coverters)

106

cosdc dmV V

Page 107: Phase Controlled-Rectifiers (AC-DC Coverters)

107Prof. M. Madhusudhan Rao, E&C Dept., MSRIT

VO(dc)

Trigger angle in degrees

030 60 90

Vdm

0.2 Vdm

0.6Vdm

-0.6 Vdm

-0.2Vdm

-Vdm

120 150 180

cosdc dmV V

Page 108: Phase Controlled-Rectifiers (AC-DC Coverters)

108

00

By varying the trigger angle we can vary the

output dc voltage across the load. Hence we can

control the dc output power flow to the load.

For trigger a . ., ngle , 0 to 90

cos is positive

0 90 ;

i e

and hence is positive

Converter

& are positive ; is positive

Controlled Rectif operates as a

Power flow is from the

ie

ac source to the d.

r.

loa

dc dc dc dc d

d

c

cV

V I P V I

Page 109: Phase Controlled-Rectifiers (AC-DC Coverters)

109Prof. M. Madhusudhan Rao, E&C Dept., MSRIT

0

0

0

0. ., 90 180 ,

is negative; is positive

For trigger angle , 90

;

is negative.

Line

to 180

cos is negative and hence

In this case the conve

Co

rte

mmutated In

r operates

s vea a

dc dc

dc dc dc

i e

V I

P V I

Power flows from the load ckt. to the i/p ac source.

The inductive load energy is fed back to the

i/p sou

rter.

rce.

Page 110: Phase Controlled-Rectifiers (AC-DC Coverters)

110Prof. M. Madhusudhan Rao, E&C Dept., MSRIT

Drawbacks Of Full Wave Controlled Rectifier With Centre Tapped Transformer

• We require a centre tapped transformer which is quite heavier and bulky.

• Cost of the transformer is higher for the required dc output voltage & output power.

• Hence full wave bridge converters are preferred.

Page 111: Phase Controlled-Rectifiers (AC-DC Coverters)

111Prof. M. Madhusudhan Rao, E&C Dept., MSRIT

Single Phase Full Wave Bridge Controlled Rectifier2 types of FW Bridge Controlled Rectifiers are

Half Controlled Bridge Converter

(Semi-Converter) Fully Controlled Bridge Converter

(Full Converter)

The bridge full wave controlled rectifier does not require a centre tapped transformer

Page 112: Phase Controlled-Rectifiers (AC-DC Coverters)

112Prof. M. Madhusudhan Rao, E&C Dept., MSRIT

Single Phase Full Wave Half Controlled Bridge

Converter (Single Phase Semi Converter)

Page 113: Phase Controlled-Rectifiers (AC-DC Coverters)

113Prof. M. Madhusudhan Rao, E&C Dept., MSRIT

Page 114: Phase Controlled-Rectifiers (AC-DC Coverters)

114Prof. M. Madhusudhan Rao, E&C Dept., MSRIT

Trigger Pattern of Thyristors

1

2

01 2

, 2 ,...

, 3 ,...

& 180

Thyristor T is triggered at

t at t

Thyristor T is triggered at

t at t

The time delay between the gating

signals of T T radians or

Page 115: Phase Controlled-Rectifiers (AC-DC Coverters)

115Prof. M. Madhusudhan Rao, E&C Dept., MSRIT

Waveforms of single phase semi-converter

with general load & FWDfor > 900

Page 116: Phase Controlled-Rectifiers (AC-DC Coverters)

116Prof. M. Madhusudhan Rao, E&C Dept., MSRIT

Single Quadrant Operation

Page 117: Phase Controlled-Rectifiers (AC-DC Coverters)

117Prof. M. Madhusudhan Rao, E&C Dept., MSRIT

Page 118: Phase Controlled-Rectifiers (AC-DC Coverters)

118Prof. M. Madhusudhan Rao, E&C Dept., MSRIT

Page 119: Phase Controlled-Rectifiers (AC-DC Coverters)

119Prof. M. Madhusudhan Rao, E&C Dept., MSRIT

1 1

2 2

Thyristor & conduct

from

Thyristor & conduct

from 2

FWD conducts during

0 to , ,...

T D

t to

T D

t to

t to

Page 120: Phase Controlled-Rectifiers (AC-DC Coverters)

120Prof. M. Madhusudhan Rao, E&C Dept., MSRIT

Load Voltage & Load Current Waveform of Single Phase Semi

Converter for < 900

& Continuous load current operation

Page 121: Phase Controlled-Rectifiers (AC-DC Coverters)

121Prof. M. Madhusudhan Rao, E&C Dept., MSRIT

vOV m

0

iO

t

( )

t0

( )

Page 122: Phase Controlled-Rectifiers (AC-DC Coverters)

122Prof. M. Madhusudhan Rao, E&C Dept., MSRIT

To Derive an Expression For The

DC Output Voltage of A

Single Phase Semi-Converter With R,L, & E Load & FWD

For Continuous, Ripple Free Load Current Operation

Page 123: Phase Controlled-Rectifiers (AC-DC Coverters)

123Prof. M. Madhusudhan Rao, E&C Dept., MSRIT

0

1.

1sin .

cos

cos cos ; cos 1

1 cos

dc OO dct

dc mO dc

mdcO dc

mdcO dc

mdcO dc

V V v d t

V V V t d t

VV V t

VV V

VV V

Page 124: Phase Controlled-Rectifiers (AC-DC Coverters)

124Prof. M. Madhusudhan Rao, E&C Dept., MSRIT

max

can be varied from a max.

2value of 0 by varying from 0 to .

For 0, The max. dc o/p voltage obtained is

Normalized dc o/p voltage is

2

11 cos

2

dc

m

m

dc

mdn

mdmdc

dcn n

V

Vto

VV

V V

VVV

V

V

1 cos2

Page 125: Phase Controlled-Rectifiers (AC-DC Coverters)

125Prof. M. Madhusudhan Rao, E&C Dept., MSRIT

RMS O/P Voltage VO(RMS)

1

22 2

12 2

1

2

2sin .

2

1 cos 2 .2

1 sin 2

22

mO RMS

mO RMS

mO RMS

V V t d t

VV t d t

VV

Page 126: Phase Controlled-Rectifiers (AC-DC Coverters)

126Prof. M. Madhusudhan Rao, E&C Dept., MSRIT

Single Phase Full Wave Full Converter

(Fully Controlled Bridge Converter)

With R,L, & E Load

Page 127: Phase Controlled-Rectifiers (AC-DC Coverters)

127Prof. M. Madhusudhan Rao, E&C Dept., MSRIT

Page 128: Phase Controlled-Rectifiers (AC-DC Coverters)

128Prof. M. Madhusudhan Rao, E&C Dept., MSRIT

Waveforms of Single Phase Full Converter

Assuming Continuous (Constant Load Current)

& Ripple Free Load Current

Page 129: Phase Controlled-Rectifiers (AC-DC Coverters)

129

Page 130: Phase Controlled-Rectifiers (AC-DC Coverters)

130Prof. M. Madhusudhan Rao, E&C Dept., MSRIT

Page 131: Phase Controlled-Rectifiers (AC-DC Coverters)

131Prof. M. Madhusudhan Rao, E&C Dept., MSRIT

i OC o n s t a n t L o a d C u rr e n t i = IO a

ii

T 1

T 2&

I a

t

t

t

I aii

T 3

T 4&

I a

I a

Page 132: Phase Controlled-Rectifiers (AC-DC Coverters)

132Prof. M. Madhusudhan Rao, E&C Dept., MSRIT

To Derive An Expression For

The Average DC Output Voltage of a Single Phase Full Converter

assuming Continuous & Constant Load Current

Page 133: Phase Controlled-Rectifiers (AC-DC Coverters)

133Prof. M. Madhusudhan Rao, E&C Dept., MSRIT

2

0

The average dc output voltage

can be determined by using the expression

1. ;

2

The o/p voltage waveform consists of two o/p

pulses during the input supply time period of

0 to 2 r

dc OO dcV V v d t

adians. Hence the Average or dc

o/p voltage can be calculated as

Page 134: Phase Controlled-Rectifiers (AC-DC Coverters)

134Prof. M. Madhusudhan Rao, E&C Dept., MSRIT

2sin .

2

2cos

22

cos

dc mO dc

mdcO dc

mdcO dc

V V V t d t

VV V t

VV V

Page 135: Phase Controlled-Rectifiers (AC-DC Coverters)

135Prof. M. Madhusudhan Rao, E&C Dept., MSRIT

0

max

max

Maximum average dc output voltage is

calculated for a trigger angle 0

and is obtained as

2 2cos 0

2

m mdmdc

mdmdc

V VV V

VV V

Page 136: Phase Controlled-Rectifiers (AC-DC Coverters)

136Prof. M. Madhusudhan Rao, E&C Dept., MSRIT

max

The normalized average output voltage is given by

2cos

cos2

O dc dcdcn n

dmdc

m

dcn nm

V VV V

V V

V

V VV

Page 137: Phase Controlled-Rectifiers (AC-DC Coverters)

137Prof. M. Madhusudhan Rao, E&C Dept., MSRIT

By plotting VO(dc) versus , we obtain the control characteristic of a single phase full wave fully controlled

bridge converter

(single phase full converter)

for constant & continuous

load current operation.

Page 138: Phase Controlled-Rectifiers (AC-DC Coverters)

138Prof. M. Madhusudhan Rao, E&C Dept., MSRIT

To plot the control characteristic of a

Single Phase Full Converter for constant

& continuous load current operation.

We use the equation for the average/ dc

output voltage

2cosm

dcO dc

VV V

Page 139: Phase Controlled-Rectifiers (AC-DC Coverters)

139Prof. M. Madhusudhan Rao, E&C Dept., MSRIT

Page 140: Phase Controlled-Rectifiers (AC-DC Coverters)

140Prof. M. Madhusudhan Rao, E&C Dept., MSRIT

VO(dc)

Trigger angle in degrees

030 60 90

Vdm

0.2 Vdm

0.6Vdm

-0.6 Vdm

-0.2Vdm

-Vdm

120 150 180

cosdc dmV V

Page 141: Phase Controlled-Rectifiers (AC-DC Coverters)

141Prof. M. Madhusudhan Rao, E&C Dept., MSRIT

• During the period from t = to the input voltage vS and the input current iS are both positive and the power flows from the supply to the load.

• The converter is said to be operated in the rectification mode

Controlled Rectifier Operation

for 0 < < 900

Page 142: Phase Controlled-Rectifiers (AC-DC Coverters)

142Prof. M. Madhusudhan Rao, E&C Dept., MSRIT

• During the period from t = to (+), the input voltage vS is negative and the input current iS is positive and the output power becomes negative and there will be reverse power flow from the load circuit to the supply.

• The converter is said to be operated in the inversion mode.

Line Commutated Inverter Operationfor 900 < < 1800

Page 143: Phase Controlled-Rectifiers (AC-DC Coverters)

143Prof. M. Madhusudhan Rao, E&C Dept., MSRIT

Two Quadrant Operation of a Single Phase Full Converter

0< < 900

Controlled Rectifier Operation

900< <1800

Line Commutated

Inverter Operation

Page 144: Phase Controlled-Rectifiers (AC-DC Coverters)

144Prof. M. Madhusudhan Rao, E&C Dept., MSRIT

To Derive An Expression For The RMS Value Of The Output Voltage

2

2

0

The rms value of the output voltage

is calculated as

1.

2 OO RMSV v d t

Page 145: Phase Controlled-Rectifiers (AC-DC Coverters)

145

The single phase full converter gives two

output voltage pulses during the input supply

time period and hence the single phase full

converter is referred to as a two pulse converter.

The rms output vo

2

ltage can be calculated as

2.

2 OO RMSV v d t

Page 146: Phase Controlled-Rectifiers (AC-DC Coverters)

146Prof. M. Madhusudhan Rao, E&C Dept., MSRIT

2 2

22

2

2

1sin .

sin .

1 cos 2.

2

cos 2 .2

mO RMS

mO RMS

mO RMS

mO RMS

V V t d t

VV t d t

tVV d t

VV d t t d t

Page 147: Phase Controlled-Rectifiers (AC-DC Coverters)

147

2

2

2

sin 222

sin 2 sin 2

2 2

sin 2 2 sin 2;

2 2

sin 2 2 sin 2

mO RMS

mO RMS

mO RMS

V tV t

VV

VV

Page 148: Phase Controlled-Rectifiers (AC-DC Coverters)

148Prof. M. Madhusudhan Rao, E&C Dept., MSRIT

2

2 2

sin 2 sin 2

2 2

02 2 2

2Hence the rms output voltage is same as the

rms input supply voltage

mO RMS

m m mO RMS

mSO RMS

VV

V V VV

VV V

Page 149: Phase Controlled-Rectifiers (AC-DC Coverters)

149Prof. M. Madhusudhan Rao, E&C Dept., MSRIT

Thyristor Current Waveforms

Page 150: Phase Controlled-Rectifiers (AC-DC Coverters)

150Prof. M. Madhusudhan Rao, E&C Dept., MSRIT

i OC o n s t a n t L o a d C u rr e n t i = IO a

ii

T 1

T 2&

I a

t

t

t

I aii

T 3

T 4&

I a

I a

Page 151: Phase Controlled-Rectifiers (AC-DC Coverters)

151Prof. M. Madhusudhan Rao, E&C Dept., MSRIT

The rms thyristor current can be

calculated as

2The average thyristor current can be

calculated as

2

O RMS

T RMS

O dc

T Avg

II

II

Page 152: Phase Controlled-Rectifiers (AC-DC Coverters)

152Prof. M. Madhusudhan Rao, E&C Dept., MSRIT

Single Phase Dual Converter

Page 153: Phase Controlled-Rectifiers (AC-DC Coverters)

153

Page 154: Phase Controlled-Rectifiers (AC-DC Coverters)

154Prof. M. Madhusudhan Rao, E&C Dept., MSRIT

Page 155: Phase Controlled-Rectifiers (AC-DC Coverters)

155Prof. M. Madhusudhan Rao, E&C Dept., MSRIT

Page 156: Phase Controlled-Rectifiers (AC-DC Coverters)

156Prof. M. Madhusudhan Rao, E&C Dept., MSRIT

1 1

2 2

The average dc output voltage of converter 1 is

2cos

The average dc output voltage of converter 2 is

2cos

mdc

mdc

VV

VV

Page 157: Phase Controlled-Rectifiers (AC-DC Coverters)

157Prof. M. Madhusudhan Rao, E&C Dept., MSRIT

0

0

1

In the dual converter operation one

converter is operated as a controlled rectifier

with 90 & the second converter is

operated as a line commutated inverter

in the inversion mode with 90

dcV V

2dc

Page 158: Phase Controlled-Rectifiers (AC-DC Coverters)

158Prof. M. Madhusudhan Rao, E&C Dept., MSRIT

1 2 2

1 2

2 1 1

2 1

1 2

2 1

2 2 2cos cos cos

cos cos

or

cos cos cos

or

radians

Which gives

m m mV V V

Page 159: Phase Controlled-Rectifiers (AC-DC Coverters)

159Prof. M. Madhusudhan Rao, E&C Dept., MSRIT

To Obtain an Expression for the

Instantaneous Circulating Current

Page 160: Phase Controlled-Rectifiers (AC-DC Coverters)

160Prof. M. Madhusudhan Rao, E&C Dept., MSRIT

• vO1 = Instantaneous o/p voltage of converter 1.

• vO2 = Instantaneous o/p voltage of converter 2.

• The circulating current ir can be determined by integrating the instantaneous voltage difference (which is the voltage drop across the circulating current reactor Lr), starting from t = (2 - 1).

• As the two average output voltages during the interval t = (+1) to (2 - 1) are equal and opposite their contribution to the instantaneous circulating current ir is zero.

Page 161: Phase Controlled-Rectifiers (AC-DC Coverters)

161Prof. M. Madhusudhan Rao, E&C Dept., MSRIT

1

1

1 2

2

2

1 2

1 2

2

1 1

1. ;

As the o/p voltage is negative

1. ;

sin for 2 to

t

r r r O Or

O

r O O

t

r O Or

O m

i v d t v v vL

v

v v v

i v v d tL

v V t t

Page 162: Phase Controlled-Rectifiers (AC-DC Coverters)

162Prof. M. Madhusudhan Rao, E&C Dept., MSRIT

1 12 2

1

sin . sin .

2cos cos

The instantaneous value of the circulating current

depends on the delay angle.

t tm

rr

mr

r

Vi t d t t d t

L

Vi t

L

Page 163: Phase Controlled-Rectifiers (AC-DC Coverters)

163Prof. M. Madhusudhan Rao, E&C Dept., MSRIT

1For trigger angle (delay angle) 0,

the magnitude of circulating current becomes min.

when , 0, 2,4,.... & magnitude becomes

max. when , 1,3,5,....

If the peak load current is , one of p

t n n

t n n

I

the

converters that controls the power flow

may carry a peak current of

4,m

pr

VI

L

Page 164: Phase Controlled-Rectifiers (AC-DC Coverters)

164Prof. M. Madhusudhan Rao, E&C Dept., MSRIT

max

max

where

,

&

4 max. circulating current

mp L

L

mr

r

VI I

R

Vi

L

Page 165: Phase Controlled-Rectifiers (AC-DC Coverters)

165Prof. M. Madhusudhan Rao, E&C Dept., MSRIT

The Dual Converter Can Be Operated In Two Different Modes Of Operation

• Non-circulating current (circulating current free) mode of operation.

• Circulating current mode of operation.

Page 166: Phase Controlled-Rectifiers (AC-DC Coverters)

166Prof. M. Madhusudhan Rao, E&C Dept., MSRIT

Non-Circulating Current Mode of Operation

• In this mode only one converter is operated at a time.

• When converter 1 is ON, 0 < 1 < 900

• Vdc is positive and Idc is positive.

• When converter 2 is ON, 0 < 2 < 900

• Vdc is negative and Idc is negative.

Page 167: Phase Controlled-Rectifiers (AC-DC Coverters)

167Prof. M. Madhusudhan Rao, E&C Dept., MSRIT

Circulating Current Mode Of Operation

• In this mode, both the converters are switched ON and operated at the same time.

• The trigger angles 1 and 2 are adjusted such that (1 + 2) = 1800 ; 2 = (1800 - 1).

Page 168: Phase Controlled-Rectifiers (AC-DC Coverters)

168Prof. M. Madhusudhan Rao, E&C Dept., MSRIT

• When 0 <1 <900, converter 1 operates as a controlled rectifier and converter 2 operates as an inverter with 900 <2<1800.

• In this case Vdc and Idc, both are positive.• When 900 <1 <1800, converter 1 operates as

an Inverter and converter 2 operated as a controlled rectifier by adjusting its trigger angle 2 such that 0 <2<900.

• In this case Vdc and Idc, both are negative.

Page 169: Phase Controlled-Rectifiers (AC-DC Coverters)

169Prof. M. Madhusudhan Rao, E&C Dept., MSRIT

Four Quadrant OperationConv. 2 Inverting

2 > 900

Conv. 2 Rectifying

2 < 900

Conv. 1 Rectifying

1 < 900

Conv. 1 Inverting

1 > 900

Page 170: Phase Controlled-Rectifiers (AC-DC Coverters)

170Prof. M. Madhusudhan Rao, E&C Dept., MSRIT

Advantages of Circulating Current Mode Of Operation

• The circulating current maintains continuous conduction of both the converters over the complete control range, independent of the load.

• One converter always operates as a rectifier and the other converter operates as an inverter, the power flow in either direction at any time is possible.

Page 171: Phase Controlled-Rectifiers (AC-DC Coverters)

171Prof. M. Madhusudhan Rao, E&C Dept., MSRIT

• As both the converters are in continuous conduction we obtain faster dynamic response. i.e., the time response for changing from one quadrant operation to another is faster.

Page 172: Phase Controlled-Rectifiers (AC-DC Coverters)

172Prof. M. Madhusudhan Rao, E&C Dept., MSRIT

Disadvantages of Circulating Current Mode Of Operation

• There is always a circulating current flowing between the converters.

• When the load current falls to zero, there will be a circulating current flowing between the converters so we need to connect circulating current reactors in order to limit the peak circulating current to safe level.

• The converter thyristors should be rated to carry a peak current much greater than the peak load current.