- Approved to OIML R60 3000 D - Total Error 0.02% - Maximum platform size 1200 x 1200 mm - Available in capacity ranges 1000, 1500 and 2000kg - Ideal for platform, tank and floor scales - Robust aluminium construction - Sealed to IP66 with a special coating - 6-wire sense technique with double shielded cable - Optional Hazardous area approval (ATEX) available Platform Load Cell 1320 Platform Load Cell, Model 1320 Photo 100 x 145 mm TECHNIQUES LIMITED

Photo 100 x 145 mm - Sensor Techniques Limited · 2020. 3. 18. · DS1320-4, 03/20 Mounting threads M16 x 2 (8 places) + Exc = Green + Sen = Blue + Sig(Inp)= Red - Sen = Brown - Exc

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Photo 100 x 145 mm - Sensor Techniques Limited · 2020. 3. 18. · DS1320-4, 03/20 Mounting threads M16 x 2 (8 places) + Exc = Green + Sen = Blue + Sig(Inp)= Red - Sen = Brown - Exc

- Approved to OIML R60 3000 D

- Total Error 0.02%

- Maximum platform size 1200 x 1200 mm

- Available in capacity ranges 1000, 1500 and 2000kg

- Ideal for platform, tank and floor scales

- Robust aluminium construction

- Sealed to IP66 with a special coating

- 6-wire sense technique with double shielded cable

- Optional Hazardous area approval (ATEX) available

Platform Load Cell1320

Platform Load Cell, Model 1320

Photo

100 x 145 mm

TECHNIQUES LIMITED

Page 2: Photo 100 x 145 mm - Sensor Techniques Limited · 2020. 3. 18. · DS1320-4, 03/20 Mounting threads M16 x 2 (8 places) + Exc = Green + Sen = Blue + Sig(Inp)= Red - Sen = Brown - Exc

2

± 10

415 ± 15

350 ± 3

10

-10 to +40

-20 to +70

< 0.4

150

200

300

5

1200 x 1200

IP66

1000, 1500, 2000NMI - Certificate TC2274/1, OIML-R60

0.050

0.050

0.030

0.100

0.020

0.017

0.010

0.040

3000

30

10000

0.020

0.017

0.010

0.014

Technical Data Model 1320

GRADE

Dimensions

TECHNIQUES LIMITEDTel. +44 (0)1446 771185 Fax +44 (0)1446 771186

Precision Load cellsAccessories and Mountings

Measuring Instruments and Systems

Number of Load Cell Intervals

Minimum Utilisation

Minimum Verification Interval

Total Error

Zero Return after 30 mins

Temperature Effect on : Span

Zero

Output at Rated Load (ORL)

Output at Rated Load Tolerance

Input Impedance

Output Impedance

Recommended Supply Voltage

Compensated Temp. Range

Operating Temperature Range

Deflection

Safe Overload

Maximum Overload

Ultimate Overload

Cable Length

Typical Platform Size

Environmental Protection

Rated Capacities (Emax)

n (max)

% Rated Cap.

Vmin=Emax/.

% Rated Load

% Appl. Load

%Appl. Ld./10K

%ORL/10K

mV/V

%

Ohm

Ohm

V

°C

°C

mm

% Rated Cap.

% Rated Cap.

% Rated Cap.

m

mm

Kg

176

11520.5 10 10

45

3

95

12

6

76

46

6-Wire Cable, 5 metres long

Electrical Connections

All Dimensions in mmSpecifications are subject to change without prior notice

DS1320-4, 03/20

Mounting threads M16 x 2 (8 places)

+ Exc = Green

+ Sen = Blue

+ Sig(Inp)= Red

- Sen = Brown

- Exc = Black

- Sig(Inp)= White

E G C3