2
The most important electromedical innovation of the last decades Second Generation Tecartherapy Frequency Selection: Yes. In need of therapy: 0.8 MHz. 1 MHz. 1.2MHz. Tuning Frequency in Different Therapeutic Areas from the same patient: Yes. The operator can select the frequency of interest in each of the channels (1 MHz 0.8 MHz 1.2 MHz). Number of Channels Available: 2 (Equivalent to treat two areas of the patient´s body simultaneously) Intelligent Channel: Yes. The same channel allows you to use the manual capacitive and resistive handprobe, and the capacitive automatic plate. Multichannel Technology: Yes.        Application of the capacitive electrode in the two channels: Yes.    Application of the resistive electrode in the two channels: Yes.    Application of the automatic plate in the two channels: Yes. Automatic Technology: Yes. Option of Crossfires (manual CAP-RES combined application): Yes. Option of Combined Manual & Automatic Treatments: Yes. Option of Bilateral Lymphatic Drainage --unattended--: Yes. Temperature Monitoring by Sensor: Yes. In automated plates only. Suggestions of Treatment by Guided Program: Yes. (Athermal. Thermal. Highly thermal). Basic or Advanced Screen: Yes. Viewing Biofeedback Parameters (absorbed energy , qualitative indication of real-time power, coupling, tempe- rature), to conduct clinical research: Yes. Safety Switch: Yes. Hygiene Systems for Accessories: Yes. Protective membranes for manual capacitive handpieces, and pouches (with or without gel) for automatic capacitive accessories. Physiotherapy & Sports Tecartherapy - Diathermy C 200 Manual or Automatic Tecartherapy Electrical Transference of Capacitive and Resistive Energy (2 channels) Therapeutic Possibilities Resistive - RES Capacitive - CAP Isolated Automatic - AUTO Unattended

Physiotherapy & Sports - Dentago · 2018. 4. 6. · The most important electromedical innovation of the last decades Second Generation Tecartherapy CAPENERGY is a registered trademark

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Physiotherapy & Sports - Dentago · 2018. 4. 6. · The most important electromedical innovation of the last decades Second Generation Tecartherapy CAPENERGY is a registered trademark

The most important electromedical innovation of the last decadesSecond Generation Tecartherapy

• FrequencySelection:Yes. In need of therapy: 0.8 MHz. 1 MHz. 1.2MHz. • TuningFrequencyinDifferentTherapeuticAreasfromthesamepatient: Yes. The operator can select the frequency

of interest in each of the channels (1 MHz 0.8 MHz 1.2 MHz).• NumberofChannelsAvailable: 2 (Equivalent to treat two areas of the patient´s body simultaneously)• IntelligentChannel:Yes. The same channel allows you to use the manual capacitive and resistive handprobe, and the

capacitive automatic plate.• MultichannelTechnology: Yes.    •     Application of the capacitive electrode in the two channels: Yes. •     Application of the resistive electrode in the two channels: Yes.•     Application of the automatic plate in the two channels: Yes. • AutomaticTechnology:Yes.• OptionofCrossfires(manualCAP-REScombinedapplication):Yes.• OptionofCombinedManual&AutomaticTreatments:Yes.• OptionofBilateralLymphaticDrainage--unattended--:Yes. • TemperatureMonitoringbySensor:Yes. In automated plates only.  • SuggestionsofTreatmentbyGuidedProgram:Yes. (Athermal. Thermal. Highly thermal).• BasicorAdvancedScreen:Yes. • ViewingBiofeedbackParameters (absorbedenergy,qualitativeindicationofreal-timepower,coupling,tempe-

rature),toconductclinicalresearch:Yes. • SafetySwitch:Yes. • HygieneSystemsforAccessories: Yes. Protective membranes for manual capacitive handpieces, and pouches (with

or without gel) for automatic capacitive accessories.

Physiotherapy & SportsTecartherapy - DiathermyC 200ManualorAutomaticTecartherapyElectrical Transference of Capacitive and Resistive Energy (2 channels)

Therapeutic Possibilities

Resistive - RESCapacitive - CAPIsolated

Automatic - AUTOUnattended

Page 2: Physiotherapy & Sports - Dentago · 2018. 4. 6. · The most important electromedical innovation of the last decades Second Generation Tecartherapy CAPENERGY is a registered trademark

www.capenergy.com

The most important electromedical innovation of the last decadesSecond Generation Tecartherapy CA

PEN

ERG

Y is

a re

gist

ered

trad

emar

k. 8

7644

09 E

MCI

M is

a re

gist

ered

trad

emar

k. 6

8556

39 E

M

Med

ical

Dev

ice.

Not

ified

Bod

y CE

012

0. D

irect

ive

93/4

2/EE

C. E

N 6

0601

-1:2

008

- Med

ical

ele

ctric

al e

quip

men

t - P

art 1

: Gen

eral

requ

irem

ents

for b

asic

saf

ety

and

esse

ntia

l per

form

ance

.EN

606

01-1

-2:2

008

- Med

ical

ele

ctric

al e

quip

men

t - P

art 1

-2: G

ener

al re

quire

men

ts fo

r bas

ic a

nd e

ssen

tial p

erfo

rman

ce -

Colla

tera

l sta

ndar

d: e

lect

rom

agne

tic c

ompa

tibili

ty -

Requ

irem

ents

and

test

s.

Physiotherapy & SportsTecartherapy - Diathermy

C200

• Upgrade:Yes.• Power:310 W channel* x 2 (620W)• Weight:12,9 Kg• Measurements:34,7 x 42 x 22 cm• IncludesFootstand:Yes.

Environmental conditionts• Temperature:68ºF-77ºF• RelativeHumidity:<80%

Technical Features

* power established in laboratory on resistive load of 400 ohms.

* Upgrade your C 200 to C 500.Upgrade to Uro-Gynecological Physiotherapy by MJS intracavitary device.

Therapeutic Combinations