2
Bulletin nº: 2009.401.00 Pig Launcher & Receiver Traps The PIG LAUNCHERS & RECEIVERS are designed for the introduction and removal of various types and sizes of PIGS within a pipeline system. Both, PIG LAUNCHER & RECEIVER are equipped with quick opening closures according to ANSI codes. The standard receivers are provided with mechanical PIG passage indicators. They have a bypass or kick-out line that is approximately one-third the pipeline size. They are also equipped with pressure gauge (display unit), vent and drain outlets. PIG LAUNCHERS & RECEIVERS are available in sizes 10” through 48”. Tecpesa can also offer complete pigging systems – specialized according to the customer’s specifications. TECPESA’s standard PIG LAUNCHERS & RECEIVERS include pressure testing, 100% weld inspection and certification. The quality control is in accordance with the client’s specifications: Radiographic Testing, Ultrasonic Testing, Magnetic Particle Examination, Hydrostatic Pressure Testing are available. TECPESA, S.A. Balmes 129 Bis, 1º, 1ª - 08008 Barcelona - Spain [email protected] Tel: +34 934 510 760 Fax: +34 934 510 793 www.tecpesa.com 29

Pig Launcher

Embed Size (px)

DESCRIPTION

documents

Citation preview

Page 1: Pig Launcher

Bulletin nº: 2009.401.00

Pig Launcher &

Receiver Traps

The PIG LAUNCHERS & RECEIVERS are designed for the introduction and removal of various types and sizes of PIGS within a pipeline system. Both, PIG LAUNCHER & RECEIVER are equipped with quick opening closures according to ANSI codes. The standard receivers are provided with mechanical PIG passage indicators. They have a bypass or kick-out line that is approximately one-third the pipeline size. They are also equipped with pressure gauge (display unit), vent and drain outlets. PIG LAUNCHERS & RECEIVERS are available in sizes 10” through 48”. Tecpesa can also offer complete pigging systems – specialized according to the customer’s specifications. TECPESA’s standard PIG LAUNCHERS & RECEIVERS include pressure testing, 100% weld inspection and certification. The quality control is in accordance with the client’s specifications: Radiographic Testing, Ultrasonic Testing, Magnetic Particle Examination, Hydrostatic Pressure Testing are available.

TECPESA, S.A. Balmes 129 Bis, 1º, 1ª - 08008 Barcelona - Spain [email protected] Tel: +34 934 510 760 Fax: +34 934 510 793 www.tecpesa.com

29

Page 2: Pig Launcher

Bulletin nº: 2009.401.00

PIG LAUNCHERS & RECEIVERS Diameters (inch) Dimensions (mm)

ø1 ø2 øv A B C D E G H I K LT 10 14 1 1/2 178 330 228 1000 584 360 1000 428 1812 2320 12 16 1 1/2 203 356 228 1300 584 360 1300 453 2112 2671 14 18 1 1/2 235 381 228 1450 584 360 1450 478 2262 2878 16 20 1 1/2 356 508 228 1727 584 360 1727 504 2539 3403 18 22 1 1/2 381 508 336 2092 638 360 2092 529 3066 3955 20 24 1 1/2 508 508 336 2670 638 360 2670 555 3644 4660 24 28 1 1/2 610 610 438 3430 689 360 3430 606 4557 5777 26 30 2 610 610 438 3850 689 360 3850 631 4977 6197 28 32 2 610 610 546 4110 734 360 4110 656 5390 6610 30 34 2 610 610 546 4300 734 360 4300 682 5580 6800 32 36 2 610 610 648 4300 794 360 4300 707 5742 6962 34 38 2 610 610 648 4300 794 360 4300 733 5742 6962 36 40 2 610 610 648 4300 794 360 4300 758 5742 6962 38 42 2 610 610 648 4300 794 360 4300 783 5742 6962 40 44 2 610 610 648 4300 794 360 4300 809 5742 6962 48 52 2 711 711 812 4300 878 360 4300 910 5990 7412

The figures indicated on the chart above may vary

TECPESA, S.A. Balmes 129 Bis, 1º, 1ª - 08008 Barcelona - Spain [email protected] Tel: +34 934 510 760 Fax: +34 934 510 793 www.tecpesa.com