PIPING & VENT SYMBOL LIST

  • Upload
    others

  • View
    10

  • Download
    0

Embed Size (px)

Citation preview

CONTROL VALVE (TWO-WAY)

PIPING & VENT SYMBOL LIST

SYMBOL: DESCRIPTION:

PITCH PIPE IN DIRECTION

UNION/FLANGE

PIPE CAP

PIPE DOWN

PIPE UP OR UP/DOWN

DIRECTION OF FLOW IN PIPE

NEW CONNECTION

SHUTOFF VALVE NORMALLY OPEN

SHUTOFF VALVE NORMALLY CLOSED

MIXING VALVE

CONTROL VALVE (THREE-WAY)

CHECK VALVE

SAFETY/RELIEF VALVE

PRESSURE REDUCING VALVE (LIQUID/GAS)

TRIPLE DUTY VALVE (IN-LINE TYPE)

"WYE" - STRAINER

"WYE" - STRAINER W/SHUTOFF VALVE AND HOSE CONNECTION WITH CAP

BASKET STRAINER

FLEXIBLE CONNECTION

PRESSURE/TEMPERATURE TEST PLUG

REDUCER - REFERENCE SPECIFICATIONFOR CONCENTRIC/ECCENTRIC AND FOT/FOB

SUCTION DIFFUSER WITH SUPPORT FOOT

AUTOMATIC AIR VENT

MANUAL AIR VENT

DRAIN VALVE WITH HOSE CONNECTION AND CAP

NATURAL GASG

HEATING WATER RETURNHWR

HEATING WATER SUPPLYHWS

SAFETY RELIEF VENTSV

DRAINDPP

GAS REGULATOR VENTGV

NOT ALL SYMBOLS MAY APPLY.

METERM

PUMP

PRESSURE GAUGE (FURNISHED WITH BALL VALVE)P

PRESSURE SENSOR (FURNISHED WITH BALL VALVE)P

FLOW SWITCHF

TEMPERATURE SENSOR WITH WELLT

THERMOMETER WITH WELL (DIAL TYPE)T

THERMOMETER WITH WELL (FILLED TYPE)

PIPING ABBREVIATION KEY

ABBR: DESCRIPTION:

ABOVE FINISHED FLOORAFF

MIXING VALVEMV

NC NEW CONNECTION

N.C. NORMALLY CLOSED

NOT IN CONTRACTNIC

NORMALLY OPENN.O.

TYPICALTYP

EQUIPMENT CALLOUT ENDING IN E (AS-E) DENOTES EXISTING EQUIPMENTAS-E

OA OUTSIDE AIR

EXHAUST/RELIEF AIREA

PLAN OR DETAIL NUMBER

PLAN OR DETAIL NAME

PLAN OR DETAIL SCALE

DETAIL REFERRED TO BY SECTION CUT

SHEET DETAIL IS LOCATED ON

NAME

1VIEW NAME1/8" = 1'-0"

1

M101

14

32

T101

SIMDETAIL REFERRED TO BY ELEVATION

SHEET DETAIL IS LOCATED ON

INDICATES SIMILAR DETAILREFERENCED IN MULTIPLE LOCATIONS

SIM

INDICATES SIMILAR DETAILREFERENCED IN MULTIPLE LOCATIONS

LEVEL NAME

10' - 0" HEIGHT ABOVEPROJECT 0' - 0"

1 INDICATES NOTE USED TO DESCRIBEADDITIONAL INFORMATION ABOUTWORK REQUIRED, SPECIFIC TO THESHEET AND/OR DETAIL

NO R HT

INDICATES DIRECTION OF TRUE NORTH

VIEW KEY

LINE TYPE KEY:

NEW WORK BY THIS CONTRACTOR(DARK SOLID LINE)

NEW WORK UNDERFLOOR OR UNDERGROUND BY THIS CONTRACTOR(DARK LONG DASHED LINE)

NEW WORK BY OTHERS AND/OR EXISTING TO REMAIN(LIGHT SOLID LINE)

EXISTING TO BE REMOVED BY THIS CONTRACTOR(DARK SHORT DASHED LINE)

GENERAL NOTES:

1. EXISTING CONDITIONS ARE SHOWN BASED ON INFORMATION OBTAINED FROM FIELD SURVEYS,EXISTING BUILDING DOCUMENTS, AND STAFF. VERIFY EXISTING CONDITIONS AND REPORT ANYCONFLICTS BEFORE PROCEEDING.

2. NOT ALL EXISTING VENTING AND PIPING ARE SHOWN. VERIFY EXISTING CONDITIONS BEFORESTARTING WORK. NOTIFY ENGINEER OF ANY CONFLICTS WITH NEW WORK.

3. FIELD VERIFY THE AVAILABLE CLEARANCES FOR WATER HEATER AND BOILER FLUES,COMBUSTION AIR DUCTS, AND ALL PIPING BEFORE FABRICATION. INCLUDE RISES AND DROPS ASREQUIRED BECAUSE OF EXISTING FIELD CONDITIONS.

4. CUT AND PATCH WALLS AS REQUIRED TO COMPLETE WORK. OBTAIN WRITTEN PERMISSION FROMA/E BEFORE CUTTING OF PENETRATING STRUCTURAL WALLS OR BOND BEAMS.

5. WHERE EXISTING MECHANICAL SYSTEMS ARE LOCATED IN AREAS THAT CONFLICT WITH NEWEQUIPMENT, PIPING, OR VENTING TO BE INSTALLED, EACH CONTRACTOR SHALL EITHER ARRANGENEW EQUIPMENT, PIPING, OR VENTING IN SUCH A FASHION THAT IT DOES NOT CONFLICT WITHEXISTING SYSTEMS, OR REWORK EXISTING MECHANICAL SYSTEMS TO ALLOW FOR INSTALLATIONOF NEW EQUIPMENT, PIPING, OR VENTING AT NO ADDITIONAL COST TO THE OWNER.

6. PROVIDE TEMPORARY CONNECTIONS AS REQUIRED TO MAINTAIN EXISTING DOMESTIC COLD ANDHOT WATER SYSTEMS IN SERVICE DURING CONSTRUCTION.

7. OBTAIN PERMISSION FROM OWNER BEFORE SHUTTING DOWN ANY SYSTEM FOR ANY REASON.MAINTAIN SERVICE TO ALL COMPONENTS THAT ARE TO REMAIN UNTIL NEW SYSTEMS AREINSTALLED.

8. MAINTAIN EXISTING DOMESTIC COLD AND HOT WATER SYSTEMS IN SERVICE UNTIL NEW SYSTEM ISCOMPLETE AND READY FOR TIE IN AND SWITCHOVER. DRAIN SYSTEM ONLY TO MAKESWITCHOVERS AND CONNECTIONS. OBTAIN PERMISSION FROM OWNER BEFORE PARTIALLY ORCOMPLETELY DRAINING SYSTEM. MAKE CHANGEOVER TO NEW SYSTEMS WITH MINIMUM OUTAGE.

9. DRAWINGS SHOWING LOCATIONS OF EQUIPMENT, FLUES, PIPING, ETC. ARE DIAGRAMMATIC ANDMAY NOT REFLECT EXACT INSTALLATION CONDITIONS. INCLUDE ALL OFFSETS AND FITTINGSREQUIRED FOR A COMPLETE INSTALLATION.

10. DO NOT SCALE DRAWINGS. FIELD VERIFY ALL DIMENSIONS AND CLEARANCES.11. COORDINATE ALL WORK WITH ALL OTHER TRADES PRIOR TO INSTALLATION TO PROVIDE

CLEARANCES REQUIRED FOR OPERATION, MAINTENANCE, CODE COMPLIANCE, AND TO VERIFYNON-INTERFERENCE WITH OTHER WORK. DO NOT FABRICATE PRIOR TO VERIFICATION OFNECESSARY CLEARANCES FOR ALL TRADES. BRING ANY INTERFERENCES OR CONFLICTS TO THEATTENTION OF THE ARCHITECT/ENGINEER BEFORE PROCEEDING WITH FABRICATION OREQUIPMENT ORDERS. REFER TO SECTIONS 22 05 00 AND 23 05 00 FOR COORDINATION DRAWINGREQUIREMENTS.

12. REVIEW SPACE REQUIREMENTS OF EQUIPMENT SPECIFIED OR SUBSTITUTED AND MAKEREASONABLE ACCOMMODATIONS IN LAYOUT AND POSITIONING TO PROVIDE PROPER ACCESS.

13. ANY CHANGES REQUIRED TO ELIMINATE CONFLICTS OR THAT RESULT FROM A FAILURE TOCOORDINATE SHALL BE MADE BY THE CONTRACTOR WITHOUT ADDITIONAL COST OR EXPENSE TOOTHERS.

14. EACH CONTRACTOR IS RESPONSIBLE FOR ALL COSTS ASSOCIATED WITH ELECTRICAL CHANGESREQUIRED FOR EQUIPMENT PROPOSED THAT DIFFERS FROM THE BASIS OF DESIGN.

15. PENETRATIONS THROUGH EXTERIOR WALLS SHALL BE SEALED WATERTIGHT.16. MAINTAIN EQUIPMENT MFR'S RECOMMENDED SERVICE CLEARANCES.17. MAINTAIN MINIMUM 3'-6” CLEARANCE IN FRONT OF ALL ELECTRICAL PANELS, MOTOR STARTERS,

SWITCHES, AND DISCONNECTS.18. PROVIDE, OR EXTEND AS REQUIRED, CONCRETE EQUIPMENT PAD FOR ALL FLOOR MOUNTED

EQUIPMENT. PAD SHALL EXTEND MINIMUM 6” BEYOND ALL SIDES OF EQUIPMENT.19. DO NOT SUPPORT EQUIPMENT, PIPING, OR DUCTWORK FROM METAL DECKING OR OTHER NON-

STRUCTURAL BUILDING ELEMENTS.20. WHERE DISTURBED BY WORK ON THIS PROJECT, REPAIR THE SPRAY APPLIED INSULATION ON THE

CEILING OF THE MECHANICAL ROOM TO MATCH EXISTING.21. IN THE EVENT MATERIAL SUSPECTED OF CONTAINING ASBESTOS (ACM) ARE ENCOURAGED, DO

NOT DISTURB AND INFORM THE A/E IMMEDIATELY SO TESTING AND ABATEMENT CAN BEARRANGED BY THE OWNER.

PLUMBING EQUIPMENT LIST

THE EQUIPMENT AND FIXTURE SCHEDULES ARE FOR THE CONVENIENCE OF THE CONTRACTOR. CONTRACTOR SHALLVERIFY QUANTITIES AND FURNISH ALL MATERIALS REQUIRED FOR FULLY OPERATIONAL SYSTEMS, WHETHER SPECIFIEDOR NOT.

CATALOG NUMBERS SHALL NOT BE CONSIDERED COMPLETE, BUT ARE GIVEN AS AN AID TO THE CONTRACTOR AND TOINDICATE THE QUALITY REQUIRED. CONTRACTOR IS RESPONSIBLE FOR COMPLETE DESCRIPTION OF MATERIAL ON THESEDRAWINGS AND IN THE SPECIFICATIONS BEFORE ORDERING. THE DESCRIPTION OF THE MATERIAL TAKES PRECEDENCEOVER THE CATALOG NUMBER. THE FIRST MANUFACTURER LISTED IS THE BASIS OF DESIGN.

CP-1 (BLDG. HWC PUMP)

DOMESTIC HOT WATER CIRCULATING PUMP - VARIABLE SPEED, LEAD-FREE BRONZE OR STAINLESS STEELCONSTRUCTION, PERMANENTLY LUBRICATED SEALED BEARINGS, MECHANICAL SEAL, OIL LUBRICATED, ECM MOTOR WITHINTEGRATED VARIABLE SPEED CONTROL AND THERMAL OVERLOAD PROTECTION, ONE SET OF DRY CONTACTS FORSTATUS OUTPUT TO BMS, FLANGED CONNECTIONS, RATED FOR 125 PSIG AT 225F, MANUFACTURER PROVIDED PUMPBODY INSULATION KIT, UL LISTED.

30 GPM @ 35 FEET OF HEAD, 1/2 HP, 200/1/60

AQUASTAT - ADJUSTABLE SETTING OF 90F TO 180F WITH STRAP-ON REMOTE SENSOR BULB, UL LISTED.

ACCEPTABLE MFRS: B&G (ECOCIRC XL 55-45), GRUNDFOS (MAGNA SERIES)

CP-2 (STORAGE TANK CIRC. PUMP)

DOMESTIC HOT WATER CIRCULATING PUMP - VARIABLE SPEED, LEAD-FREE BRONZE OR STAINLESS STEELCONSTRUCTION, PERMANENTLY LUBRICATED SEALED BEARINGS, MECHANICAL SEAL, OIL LUBRICATED, ECM MOTOR WITHINTEGRATED VARIABLE SPEED CONTROL AND THERMAL OVERLOAD PROTECTION, ONE SET OF DRY CONTACTS FORSTATUS OUTPUT TO BMS, FLANGED CONNECTIONS, RATED FOR 125 PSIG AT 225F, MANUFACTURER PROVIDED PUMPBODY INSULATION KIT, UL LISTED.

CP-2: 12 GPM @ 20 FEET OF HEAD, 1/6 HP, 115/1/60.

AQUASTAT - ADJUSTABLE SETTING OF 90F TO 180F WITH STRAP-ON REMOTE SENSOR BULB, UL LISTED.

ACCEPTABLE MFRS: B&G (ECOCIRC XL 36-45), GRUNDFOS (MAGNA SERIES)

ET-1

EXPANSION TANK - WELDED BLACK STEEL CONSTRUCTION, ASME STAMPED, GUARANTEED AIRTIGHT AND LEAKPROOF,STAINLESS STEEL SYSTEM CONNECTION, HEAVY DUTY BUTYL DIAPHRAGM AND RIGID POLYPROPYLENE LINERMECHANICALLY BONDED TO TANK TO PROVIDE 100% NON-CORROSIVE WATER RESERVOIR. DIAPHRAGM AND LINERSHALL BE APPROVED FOR USE IN POTABLE WATER SYSTEMS. ALL WETTED COMPONENTS SHALL BE OF FDA APPROVEDMATERIALS. PROVIDE STANDARD SCHRADER AIR VALVE FOR FIELD CHARGING. TANK SHALL BE LEAD-FREE ASDESCRIBED IN THE SAFE DRINKING WATER ACT 2014 (0.25% MAX. LEAD).

TANK SHALL HAVE A WORKING TEMPERATURE OF 200F AND WORKING PRESSURE OF 125 PSIG. MINIMUM TANK VOLUMESHALL BE 25 GALLONS WITH MINIMUM ACCEPTING VOLUME OF 19 GALLONS. FACTORY PRE-CHARGE TO 55 PSIG.

ACCEPTABLE MFRS - AMTROL (THERM-X-TROL), TACO (PAX SERIES), WESSELS (TX)

MV-1

MIXING VALVE - MULTIPLE HI/LO MASTER THERMOSTATIC MIXING VALVE ARRANGEMENT FOR TEMPERED WATERCONTROL. ALL BRONZE/BRASS CONSTRUCTION, ROUGH BRASS FINISH, UNION INLETS WITH STRAINERS, COMBINATIONCHECK STOPS OR SEPARATE SUPPLY CHECK VALVES AND SHUTOFF VALVES, DIAL THERMOMETER ON OUTLET. MOUNTASSEMBLY ON UNISTRUT STAND WITH MIXING VALVE ABOUT 4 FT. ABOVE FLOOR.

RATED FOR 116 GPM OUTPUT MAXIMUM AT 10 PSI DIFFERENTIAL AND 8 GPM OUTPUT MINIMUM BASED ON CONTINUOUSRECIRCULATION. UNIT SHALL MIX 140F HOT WATER SUPPLY AND 40F COLD WATER SUPPLY FOR 105F OUTLET.

PROVIDE FIELD ADJUSTMENT BY FACTORY AUTHORIZED REPRESENTATIVE. UNIT SHALL BE ASSE 1017 LISTED ANDAPPROVED. ASSEMBLY SHALL COMPLY WITH FEDERAL ACT S.3874.

ACCEPTABLE MFRS - LEONARD (TM-LF SERIES), BRADLEY (HL), POWERS (LFSH1430 SERIES), LAWLER (800 PI SERIES)

T-1 & 2

DOMESTIC HOT WATER STORAGE TANK - VERTICAL GLASS-LINED, HEAVY GAUGE STEEL JACKET, BAKED ENAMEL FINISH,200 GALLON CAPACITY, 30" DIAMETER X 71" HIGH, MAGNESIUM ANODE ROD(S), FIBERGLASS OR FOAM INSULATIONTOMEET LATEST ASHRAE/IES 90.1B STANDARD, 2" INLET AND OUTLET, DRAIN AND RELIEF VALVE OPENINGS, ASME T&PRELIEF VALVE, 11" X 15" HANDHOLE, 150 PSIG WORKING PRESSURE, ASME STAMPED, 5-YEAR WARRANTY.

ACCEPTABLE MFRS - STATE (PVG SERIES), CEMLINE (JST SERIES)

WH-1 & 2

WATER HEATER - GAS-FIRED, CONDENSING, SEALED COMBUSTION, VERTICAL, MINIMUM 94% EFFICIENT, METAL CABINET,BAKED ENAMEL FINISH, ASME STAMPED, GLASS-LINED STEEL OR STAINLESS STEEL TANK, 160 PSI WORKING PRESSURE,FIBERGLASS OR FOAM INSULATION, BRASS WATER CONNECTIONS AND DRAIN VALVE, ASME APPROVED T&P RELIEFVALVE, MULTIPLE MAGNESIUM ANODE RODS, HIGH TEMPERATURE GAS SHUT-OFF, AUTOMATIC WATER THERMOSTAT,BUILT-IN GAS REGULATING VALVE, ADJUSTABLE TEMPERATURE RANGE, 3-YEAR WARRANTY, UL LISTED, COMPLIANT TONAECA, ASHRAE 90.1 AND ASHRAE 90A.

119 GALLON CAPACITY, 499,900 BTUH INPUT NATURAL GAS, 576 GPH RECOVERY AT 100F RISE.

7" W.C. GAS INLET PRESSURE.

ELECTRICAL REQUIREMENTS - 120/1/60 CIRCUIT FOR BLOWER AND CONTROLS, HARD-WIRED.

SET WATER TEMPERATURE AT 140F.

ACCEPTABLE MFRS: A.O. SMITH (CYCLONE MXi BTH), BRADFORD WHITE (EF SERIES)

PROVIDE A CONDENSATE DRAIN NEUTRALIZATION TANK FOR EACH WATER HEATER WITH TWO SPARE SETS OFNEULTRALIZING PELLETS. JJM BOILER WORKS JM-50 OR EQUIVALENT. DRAIN PIPING SHALL BE SCH. 40 STAINLESS STEELAND EXTENDED TO NEAREST FLOOR DRAIN.

KEYNAME

A.

B.

C.

D.

E.

F.

SCHEDULE GENERAL NOTES

DISCONNECT AND CONTROLLER STARTER FURNISHED AND

INSTALLED BY:

MFR = MANUFACTURER

EC = ELECTRICAL CONTRACTOR

MC = FURNISHED BY MECHANICAL CONTRACTOR, INSTALLED

BY ELECTRICAL CONTRACTOR

MFR/EC = FURNISHED LOOSE BY MANUFACTURER

INSTALLED BY ELECTRICAL CONTRACTOR

DISCONNECT TYPE:

F = FUSED

NF = NON-FUSED

CONTROLLER STARTER TYPE:

FV = FULL VOLTAGE

WYE = WYE-DELTA

SS = SOLID STATE (SOFT START)

MS = MANUAL STARTER

VFD = VARIABLE FREQUENCY DRIVE

VFD/B = VARIABLE FREQUENCY DRIVE WITH BYPASS

FAN RPM SHALL NOT EXCEED 110% OF SCHEDULED VALUE,

WITH THE SCHEDULED WHEEL TYPE. SUBSTITUTION OF BI OR BIA

FANS FOR FC IS ACCEPTABLE IF EFFICIENCY IS NOT LOWER.

NO EQUIPMENT SHALL BE SELECTED ABOVE 90% OF MOTOR

NAME PLATE RATING.

MUST BE WITHIN +/- 10% OF SCHEDULED RPM.

SCHEDULE GENERAL NOTES

Tyso

n a

nd

Bill

y A

rch

ite

cts

, P

.C.

4000 M

ors

ay D

rive

Rockfo

rd,

IL

61107

(815)

229-8

222

FA

X: (8

15)

229-8

218

Sheet No:

ww

w.tysonandbill

y.c

om

Drn

.A

pp

d.

Pro

ject N

um

be

rD

ate

REVISION DATE

BO

ND

ING

CO

.C

ON

TR

AC

TO

R

OW

NE

RA

RC

HIT

EC

T

M000

ME

CH

AN

ICA

L C

OV

ER

SH

EE

TS

PE

NC

ER

TO

WE

R B

OIL

ER

RE

PLA

CE

ME

NT

111 2

0T

H S

TR

EE

T R

OC

K IS

LA

ND

, IL

12-9

810

3/2

3/1

7K

EV

MA

GK

EIS

TO

REFERENCE SCALE IN INCHES

0 1 2 3

ENGINEERINGCONSULTANTS 309.788.0673 FAX: 309.786.5967

www.kjww.com

623 26TH AVENUEQUAD CITIES, ILLINOIS 61201

PROJECT #

Illinois Design Firm Registration #184-000973

KJWW ENGINEERING RESERVES PROPRIETARY RIGHTS, INCLUDING COPYRIGHTS,TO THIS DRAWING AND THE DATA SHOWN THEREON. SAID DRAWING AND/OR DATAARE THE EXCLUSIVE PROPERTY OF KJWW ENGINEERING AND SHALL NOT BE USEDOR REPRODUCED FOR ANY OTHER PROJECT WITHOUT THE EXPRESS WRITTENAPPROVAL AND PARTICIPATION OF KJWW ENGINEERING. © 2017 KJWW CORP.

The FUTURE.Built SMARTER.

®

00161450.00

NOTES:1. REFER TO KJWW SPECIFICATIONS 23 52 33.14B FOR ADDITIONAL INFORMATION.2. PROVIDE WITH NEUTRALIZER FOR BOILER AND FLUE CONDENSATE INCLUDING ALL ASSOCIATED DRAIN PIPING IN ACCORDANCE WITH MFR'S RECOMMENDATIONS.3. PROVIDE VENT AND COMBUSTION AIR DUCT IN ACCORDANCE WITH MFR’S RECOMMENDATIONS.4. PROVIDE WITH CSD-1 CONTROLS.5. BOILER GAS REGULATOR SHALL BE CAPABLE OF 4” W.C. MINIMUM GAS PRESSURE.

BOILER SCHEDULE - HOT WATER

TAG NAME

MAX. DIMENSIONS

FUELTURNDOWN

RATIO INPUT MBH OUTPUT MBH EWT °F LWT °FOPERATING

PRESSURE PSI

ELECTRICAL

MANUFACTURER MODEL NOTESLENGTH WIDTH HEIGHT VOLTAGE PHASES

DISCONNECT CONTROLLER/ STARTER

BY (NOTE A)TYPE (NOTE

B) BY (NOTE A) SCCR

BLR-1 46" 28.3" 79.1" NG 7"W.C. 3:1 1500 1420 150 180 60 200 V 3 E.C. FV MFR 5000 THERMAL SOLUTIONS EVCA 1500 NOTES 1, 2, 3, 4 & 5

BLR-2 46" 28.3" 79.1" NG 7"W.C. 3:1 1500 1420 150 180 60 200 V 3 E.C. FV MFR 5000 THERMAL SOLUTIONS EVCA 1500 NOTES 1, 2, 3, 4 & 5

BLR-3 46" 28.3" 79.1" NG 7"W.C. 3:1 1500 1420 150 180 60 200 V 3 E.C. FV MFR 5000 THERMAL SOLUTIONS EVCA 1500 NOTES 1, 2, 3, 4 & 5

NOTES: 1.REFER TO KJWW SPECIFICATIONS 23 21 23 FOR ADDITIONAL INFORMATION. 2.PUMP CONTROLLED THRU BOILER CONTROL PANEL. 3.PROVIDE SHAFT GROUNDING AS REQUIRED IN THE MOTOR SPECIFICATION 23 05 13.

PUMP SCHEDULE

TAGNAME

AREASERVED GPM

PUMP FT.HEAD ATDESIGN

MINIMUMPUMP

EFFICIENCYINLETSIZE OUTLET SIZE

IMPELLERSIZE BHP

ELECTRICAL (NOTE 1)

MANUFACTURER MODEL NOTESHP

(NOTE E) RPM VOLTAGE PHASES

DISCONNECT CONTROLLER/ STARTER

BY(NOTE A)

TYPE(NOTE B)

BY(NOTE A)

TYPE(NOTE C)

P-1 BLR-1 95.0 40.00 71.6 2" 2" 6.500 1.78 2 1725 200 V 3 E.C. F BLR MFR FV B & G E-90 2AB NOTES 1 & 2

P-2 BLR-2 95.0 40.00 71.6 2" 2" 6.500 1.78 2 1725 200 V 3 E.C. F BLR MFR FV B & G E-90 2AB NOTES 1 & 2

P-3 BLR-3 95.0 40.00 71.6 2" 2' 6.500 1.78 2 1725 200 V 3 E.C. F BLR MFR FV B & G E-90 2AB NOTES 1 & 2

P-4 HEATING 390.0 60.00 80 4" 3" 8.250 7.79 10 1770 200 V 3 E.C. F E.C. VFD B & G E-1510 3BD NOTES 1 & 3

P-5 HEATING 390.0 60.00 80 4" 3" 8.250 7.79 10 1770 200 V 3 E.C. F E.C. VFD B & G E-1510 3BD NOTES 1 & 3

MAIL ROOM102

MECHANICAL

EQUIPMENT114

STORAGE115

CORRIDOR117

WH-2

WH-1

T-2

T-1

ET-1

MV-1

BLR-1

BLR-2

BLR-3

NC

NC

4" G

4" GEXISTING GAS

REGULATOR

EXISTING GAS METER

1 1/4" GV 3/4" GV (TYP.3)

CP-1

1

1

1

1

CP-2

5 2

1" D

DISCHARGE INTOFLOOR DRAIN

NCNC

MOUNT NEUTRALIZERON WALL ABOUT 12" AFF.

3

1 1/4" HWC

2 1/2" CW

2" G

2" HW

3"HW

3"CW

2 1/2" HW140

4

PROVIDE NEW 4" CONCRETEHOUSEKEEPING PAD.

MAIL ROOM102

MECHANICAL

EQUIPMENT114

STORAGE115

CORRIDOR117

D3

D3

D2

D2

D1

WH-1

WH-2

ST-1

ST-2

ET-1 MV-1, PROVIDE WITH SUPPORTSTAND AND ANCHOR TOHOUSEKEEPING PAD.

BLR-1

BLR-2

BLR-3

2" G (TYP.3)

4" G

NC

4" G

NC

1 1/2" G (TYP.2)

EXISTING

GAS METER

EXISTING GAS

REGULATOR

NC

2" G

Tyso

n a

nd

Bill

y A

rch

ite

cts

, P

.C.

4000 M

ors

ay D

rive

Rockfo

rd,

IL

61107

(815)

229-8

222

FA

X: (8

15)

229-8

218

Sheet No:

ww

w.tysonandbill

y.c

om

Drn

.A

pp

d.

Pro

ject N

um

be

rD

ate

REVISION DATE

BO

ND

ING

CO

.C

ON

TR

AC

TO

R

OW

NE

RA

RC

HIT

EC

T

M100

PLU

MB

ING

FLO

OR

PLA

NS

SP

EN

CE

R T

OW

ER

BO

ILE

RR

EP

LA

CE

ME

NT

111 2

0T

H S

TR

EE

T R

OC

K IS

LA

ND

, IL

12-9

810

3/2

3/1

7K

EV

MA

GK

EIS

TO

REFERENCE SCALE IN INCHES

0 1 2 3

ENGINEERINGCONSULTANTS 309.788.0673 FAX: 309.786.5967

www.kjww.com

623 26TH AVENUEQUAD CITIES, ILLINOIS 61201

PROJECT #

Illinois Design Firm Registration #184-000973

KJWW ENGINEERING RESERVES PROPRIETARY RIGHTS, INCLUDING COPYRIGHTS,TO THIS DRAWING AND THE DATA SHOWN THEREON. SAID DRAWING AND/OR DATAARE THE EXCLUSIVE PROPERTY OF KJWW ENGINEERING AND SHALL NOT BE USEDOR REPRODUCED FOR ANY OTHER PROJECT WITHOUT THE EXPRESS WRITTENAPPROVAL AND PARTICIPATION OF KJWW ENGINEERING. © 2017 KJWW CORP.

The FUTURE.Built SMARTER.

®

00161450.00

NO R HT

1/4" = 1'-0"2FIRST FLOOR PLAN - PLUMBING

NO R HT

1/4" = 1'-0"1FIRST FLOOR PLAN DEMOLITION - PLUMBING

3PLUMBING ISOMETRIC

NOTES:1. REFER TO 1/M200 FOR DOMESTIC WATER FLOW DIAGRAM AND REQUIRED PIPING DEMOLITION WORK.

NOTES:1. REFER TO 2/M200 FOR DOMESTIC WATER FLOW DIAGRAM.

DEMOLITION KEYNOTES:1. REMOVE CIRCULATION PUMPS SERVING EXISTING HEAT

EXCHANGERS AND DOMESTIC HOT WATER STORAGE TANKS ANDCONTROL WIRING.

2. REMOVE HEAT EXCHANGERS AND ASSOCIATED PIPING. DOMESTICCOLD WATER BRANCH PIPING SHALL BE REMOVED BACK TO MAINAND PREPARE FOR NEW CONNECTION.

3. REMOVE DOMESTIC HOT WATER BOILER, ASSOCIATED PIPING ANDCONTROLS.

KEYNOTES:1. ARRANGE PIPING TO ALLOW FUTURE REMOVAL AND REPLACEMENT

OF EQUIPMENT WITH THE LEAST AMOUNT OF PIPE DISASSEMBLY.2. ROUTE BOILER GAS REGULATOR VENT PIPING TO OUTDOORS.

LOCATE TERMINATIONS BETWEEN WINDOWS AND AS HIGH ASPOSSIBLE DIRECTLY UNDER PRECAST PANEL. TERMINATE VENTSWITH ELBOW POINTED DOWN AND INSECT SCREEN. SEAL ALLEXTERIOR WALL PENETRATIONS WATER TIGHT.

3. NEUTRALIZER SHALL BE JJM BOILER WORKS JM-50 OREQUIVALENT. PROVIDE WITH 2 SETS OF REPLACEMENT PELLETS.

4. 1" SCH. 40 316 STAINLESS STEEL DRAIN PIPE CONNECTED TOBOTTOM OF CHIMNEY LINER TEE AND EXTENDED ALONG WALL TONEUTRALIZER AND FLOOR DRAIN. MOUNT PIPE TO WALL ABOUT 18"ABOVE FLOOR WITH 1/4"/FT SLOPE TO DRAIN.

5. EXTEND 1-1/4" GAS REGULATOR VENT FROM MIDAMERICANENERGY REGULATOR OVER AND ABOVE WINDOW AND TERMINATENEXT TO OTHER GAS VENTS WITH ELBOW POINTING DOWN ANDREMOVABLE INSECT SCREEN. COORDINATE REQUIREMENTS WITHMIDAMERICAN ENERGY. COORDINATE ROUTING WITH A/E.

25

NOTES:1. AS PART OF THIS PROJECT THE ENTIRE DOMESTIC WATER HEATING

SYSTEM INCLUDING BOILER, PLATE FRAME HEAT EXCHANGERS,STORAGE TANKS, CIRCULATING PUMPS AND ALL ASSOCIATED PIPINGAND CONTROLS WITHIN THE BOILER ROOM SHALL BE DEMOLISHED. NOTALL PIPING AND COMPONENTS TO BE DEMOLISHED ARE SHOWN ONTHIS PLAN VIEW. REFER TO 1/M200 FOR PIPING DEMOLITION.

2. DOMESTIC COLD AND HOT WATER SHALL BE MAINTAINED IN OPERATIONTHROUGHOUT THE CONSTRUCTION PERIOD EXCEPT FOR SCHEDULEDOUTAGES AS COORDINATED WITH OWNER.

3. A SINGLE OUTAGE (9:00 A.M. to 5:00 P.M. ON A WEEK DAY) IS PERMITTEDTO MAKE THE SWITCH-OVER TO THE NEW DOMESTIC WATER HEATERS(WH-1 & WH-2). THE OUTAGE SHALL BE COORDINATED AND SCHEDULEDWITH THE OWNER AT LEAST ONE WEEK IN ADVANCE.

4. SHORTER OUTAGES MAY BE REQUIRED TO COMPLETE INSTALLATION OFNEW STORAGE TANKS (ST-1 & ST-2) AND MIXING VALVE (MV-1),SCHEDULE OUTAGE WITH OWNER.

5. ENSURE THE NEW DOMESTIC HOT WATER SYSTEM IS PROPERLYFLUSHED AND DISINFECTED EACH TIME BEFORE BEING PUT INTOOPERATION.

6. PRIME AND PAINT ALL EXTERIOR GAS VENT PIPING TO MATCH BUILDINGWALL. COLOR SELECTED BY A/E.

MAIL ROOM102

MECHANICAL

EQUIPMENT114

STORAGE115

CORRIDOR117

P-4

WH-2

WH-1

T-2

T-1

ET-1

MV-1

ET-2

BLR-1

BLR-2

BLR-3

P-1

P-2

P-3

6" HWR

6" HWS

6" HWS

P-5

AIR SEPARATOR

4" HWS

6" HWS

4" HWR 3" HWS

4" HWR

3" HWS6" HWS

ENLARGE CONCRETE PAD AS REQUIREDTO ACCOMMODATE NEW EQUIPMENT.

ENLARGE CONCRETE PADS AS REQUIREDTO ACCOMMODATE NEW PUMPS.

CHEMICAL POT FEEDER

MAIL ROOM102

MECHANICAL

EQUIPMENT114

STORAGE115

CORRIDOR117

4" HWS

6" HWS

4" HWR 3" HWS

4" HWR

3" HWS

REMOVE AND REUSE CHEMICALPOT FEEDER. REFER TO 2/M201FOR NEW PIPING.

REMOVEEXPANSION TANK

1

1

1

2

REMOVE AIRSEPARATOR.

REMOVE SECONDARY PUMPS

AIR SEPARATOR

6" DECOUPLER

6" HWS

4" HWS

4" HWR

3" HWS

4" HWR

3" HWS

NC

6" HWS

BLR-1

EXTEND HOUSEKEEPINGPAD AS REQUIRED. P-4

P-5

P-2

P-3

P-1

BLR-2

BLR-3

6" HWS

6" HWR

6" HWS

NC

6" HWS4" HWS

ET-2

Tyso

n a

nd

Bill

y A

rch

ite

cts

, P

.C.

4000 M

ors

ay D

rive

Rockfo

rd,

IL

61107

(815)

229-8

222

FA

X: (8

15)

229-8

218

Sheet No:

ww

w.tysonandbill

y.c

om

Drn

.A

pp

d.

Pro

ject N

um

be

rD

ate

REVISION DATE

BO

ND

ING

CO

.C

ON

TR

AC

TO

R

OW

NE

RA

RC

HIT

EC

T

M101

HE

AT

ING

FLO

OR

PLA

NS

SP

EN

CE

R T

OW

ER

BO

ILE

RR

EP

LA

CE

ME

NT

111 2

0T

H S

TR

EE

T R

OC

K IS

LA

ND

, IL

12-9

810

3/2

3/1

7K

EV

MA

GK

EIS

TO

REFERENCE SCALE IN INCHES

0 1 2 3

ENGINEERINGCONSULTANTS 309.788.0673 FAX: 309.786.5967

www.kjww.com

623 26TH AVENUEQUAD CITIES, ILLINOIS 61201

PROJECT #

Illinois Design Firm Registration #184-000973

KJWW ENGINEERING RESERVES PROPRIETARY RIGHTS, INCLUDING COPYRIGHTS,TO THIS DRAWING AND THE DATA SHOWN THEREON. SAID DRAWING AND/OR DATAARE THE EXCLUSIVE PROPERTY OF KJWW ENGINEERING AND SHALL NOT BE USEDOR REPRODUCED FOR ANY OTHER PROJECT WITHOUT THE EXPRESS WRITTENAPPROVAL AND PARTICIPATION OF KJWW ENGINEERING. © 2017 KJWW CORP.

The FUTURE.Built SMARTER.

®

00161450.00

NO R HT

1/4" = 1'-0"1FIRST FLOOR PLAN - PIPING

NO R HT

1/4" = 1'-0"2FIRST FLOOR PLAN DEMOLITION - PIPING

NO SCALE3PIPING ISOMETRIC

NOTES:1. THE EXISTING HEATING WATER SYSTEM SHALL NOT BE DISABLED

UNTIL HEATING IS NO LONGER NEEDED IN THE BUILDING. THE NEWHEATING SYSTEM SHALL BE COMPLETE, TESTED, BALANCED ANDFULLY OPERATIONAL BY SEPTEMBER 1, 2017.

2. REMOVE EXISTING BOILER AND ALL ASSOCIATED PUMPS, PIPING ANDCONTROLS.

3. PROVIDE EQUIPMENT AND PIPING COORDINATION DRAWINGS FOR A/EAPPROVAL BEFORE BEGINNING WORK. REFER TO SECTION 23 05 00.

4. NEATLY ROUTE ALL DRAIN PIPING TO THE NEAREST FLOOR DRAIN.COORDINATE ROUTING WITH A/E TO MAXIMIZE ACCESS AND AVOID TRIPHAZARDS.

KEYNOTES:1. REMOVE HEATING BOILER AND ASSOCIATED PUMP, PIPING AND

CONTROLS.2. REMOVE DOMESTIC WATER BOILER AND ASSOCIATED PUMP, PIPING

AND CONTROLS.

MAIL ROOM102

MECHANICAL

EQUIPMENT114

STORAGE115

CORRIDOR117

3

M10218"Ø FLUE

12

"Ø F

LU

E

8"Ø FLUE (TYP.3)

WH-1

WH-2 BLR-1

BLR-2

BLR-3

2

1

4

5

ALL FLUES SHALL BE DOUBLE WALL UPTO CONNECTION TO CHIMNEY LINERBOOT TEE. REFER TO SECTION 23 51 00.

BOILER VENT DRAFTCONTROL PANEL.REFER TO SECTION 2351 00.

3

6

MAIL ROOM102

MECHANICAL

EQUIPMENT114

STORAGE115

CORRIDOR117

3

M102

EXISTING LOUVER TO REMAIN.

REMOVE DAMPER, ACTUATORAND ALL ASSOCIATED CONTROLS.

REMOVE ALL BOILER FLUESBACK TO CONNECTION TOCHIMNEY.

Tyso

n a

nd

Bill

y A

rch

ite

cts

, P

.C.

4000 M

ors

ay D

rive

Rockfo

rd,

IL

61107

(815)

229-8

222

FA

X: (8

15)

229-8

218

Sheet No:

ww

w.tysonandbill

y.c

om

Drn

.A

pp

d.

Pro

ject N

um

be

rD

ate

REVISION DATE

BO

ND

ING

CO

.C

ON

TR

AC

TO

R

OW

NE

RA

RC

HIT

EC

T

M102

FLU

E &

IN

TA

KE

FLO

OR

PLA

NS

SP

EN

CE

R T

OW

ER

BO

ILE

RR

EP

LA

CE

ME

NT

111 2

0T

H S

TR

EE

T R

OC

K IS

LA

ND

, IL

12-9

810

3/2

3/1

7K

EV

MA

GK

EIS

TO

REFERENCE SCALE IN INCHES

0 1 2 3

ENGINEERINGCONSULTANTS 309.788.0673 FAX: 309.786.5967

www.kjww.com

623 26TH AVENUEQUAD CITIES, ILLINOIS 61201

PROJECT #

Illinois Design Firm Registration #184-000973

KJWW ENGINEERING RESERVES PROPRIETARY RIGHTS, INCLUDING COPYRIGHTS,TO THIS DRAWING AND THE DATA SHOWN THEREON. SAID DRAWING AND/OR DATAARE THE EXCLUSIVE PROPERTY OF KJWW ENGINEERING AND SHALL NOT BE USEDOR REPRODUCED FOR ANY OTHER PROJECT WITHOUT THE EXPRESS WRITTENAPPROVAL AND PARTICIPATION OF KJWW ENGINEERING. © 2017 KJWW CORP.

The FUTURE.Built SMARTER.

®

00161450.00N

O R HT

1/4" = 1'-0"1FIRST FLOOR PLAN - NEW WORK

NO R HT

1/4" = 1'-0"2FIRST FLOOR PLAN - DEMOLITION

1/4" = 1'-0"3FLUE SECTION

KEYNOTES:1. ORIGINAL BUILDING DRAWINGS SHOW A 24" DIAMETER CHIMNEY FLUE

GROUTED IN ON ALL SIDES. THE M.C. SHALL REMOVE AND REINSTALLTHE MASONRY CHIMNEY ENCLOSURE ON FIRST FLOOR AND CHIMNEYLINER AND GROUT AS REQUIRED TO INSTALL A NEW CHIMNEY LINER.THE M.C. SHALL VERIFY THE EXISTING CHIMNEY FLUE INSIDEDIAMETER, MATERIAL AND CONDITION AND REPORT IT TO ENGINEERBEFORE BEGINNING WORK.

2. FURNISH AND INSTALL WATER HEATER VENTS AND COMBUSTION AIRINTAKES WITH CONCENTRIC VENT TERMINATIONS IN ACCORDANCEWITH WATER HEATER MFR'S RECOMMENDATIONS. INSTALLCONCENTRIC VENTS CENTERED BETWEEN WINDOWS AND AS HIGH ASPOSSIBLE (DIRECTLY UNDER PRECAST PANEL). COORDINATE THEEXACT PLACEMENT OF THE WALL PENETRATIONS WITH THE A/E PRIORTO STARTING WORK TO ENSURE CODE REQUIRED CLEARANCESFROM WINDOWS ARE MET. SEAL WALL PENETRATIONS WATERTIGHT.PRIME AND PAINT EXTERIOR PORTION OF VENTS TO MATCH EXTERIORWALL COLOR.

3. PROVIDE DRAFT CONTROL DAMPER IN THE OUTLET FLUE OF EACHBOILER. REFER TO SECTION 23 51 00 FOR CONTROL DAMPERSPECIFICATIONS AND ASSOCIATED CONTROLS.

4. 8" COMBUSTION AIR. COMBUSTION AIR DUCT SIZES AND INSTALLATIONSHALL BE IN ACCORDANCE WITH THE BOILER MFR'SRECOMMENDATIONS. M.C. SHALL VERIFY SIZES AND REQUIREMENTSWITH THE BOILER MFR. AND INCLUDE ASSOCIATED COSTS IN BID.REFER TO SECTION 23 51 00 FOR ADDITIONAL REQUIREMENTS.

5. PROVIDE 12" DEEP GALVANIZED SHEET METAL PLENUM ON THEBACKSIDE OF THE EXISTING LOUVER. PROVIDE 45 DEGREE CHAMFERAT TOP OF PLENUM TO CONNECT COMBUSTION AIR DUCTS TO. SLOPEBOTTOM OF PLENUM SUCH THAT ANY MOISTURE IN THE PLENUM WILLDRAIN OUT THROUGH LOUVER. PROVIDE 24"W x 18"H INSULATEDACCESS DOOR IN THE PLENUM TO CLEAN BACKSIDE OF LOUVER.INSULATE THE ENTIRE PLENUM ON THE OUTSIDE WITH 2" THICK DUCTBOARD INSULATION.

6. PROVIDE 3/4" SCH. 40 316 STAINLESS STEEL PIPING WITH TRAP FROMTHE BOTTOM OF THE FLUE TEE AT EACH BOILER TO THENEUTRALIZER AND FLOOR DRAIN.

NEW 18" DIA. CHIMNEY LINER.REFER TO SECTION 23 51 00FOR REQUIREMENTS. FIELDVERIFY EXACT LENGTH OFNEW CHIMNEY REQUIRED.

BOOT TEE WITH 1" DRAINCONNECTION.

EXTEND 1" SCH. 40 316 STAINLESSSTEEL DRAIN PIPE TO NEUTRALIZERAND FLOOR DRAIN. REFER TO2/M100 FOR CONTINUATION.

LEVEL 1

0'-0"

LEVEL 2

10'-10"

LEVEL 3

18'-8"

LEVEL 4

27'-4"

LEVEL 8

62'-0"

LEVEL 9

70'-8"

ROOF

79'-2"

CHIMNEY

99'-6"(FIELD VERIFY)

PROVIDE RAIN CAP ANDWATERTIGHT FLASHING ATTOP OF MASONRY CHIMNEYENCLOSURE. PRIME ANDPAINT RAIN CAP ANDEXPOSED CHIMNEY LINERAND FLASHING. COLORSELECTED BY A/E.

TT

M

4"G

4"CW

6"HWR

6"HWS

1/2"NCW

A

HWC

HW

C

1-1

/2"G

REMOVE DOMESTIC WATER BOILERINCLUDING ALL ASSOCIATEDPIPING, FLUE AND CONTROLS.

REMOVE PLATE AND FRAME HEATEXCHANGER INCLUDING ALLASSOCIATED PUMPS AND PIPING.

REMOVEEXPANSION TANK.

REMOVE DOMESTIC HOTWATER STORAGE TANKAND ALL ASSOCIATEDPIPING.

4"HWHWC

REMOVE DOMESTIC HOTWATER CIRC. PUMP ANDPIPING.

REFER TO 1/M201 FORCONTINUATION.

HWC

CP-1

3"HW

A

MV-1

CP-2ET-1

REFER TO HEATING WATERFLOW DIAGRAM 2/M201 FORCONTINUATION.

2"C

W

2"C

W

2"H

W

1-1/4"HWC

2-1/2"CW3"CW4"CW

4"HW

1-1/4"HWC

1-1/2"HW

2"G 2"G

1 1/2"G

3"H

W

2"H

W140

2"H

W140

2-1/2"HW140

1"

2-1/2"HW140

4"G

4"G

6

6

2-1

/2"

2"

2"

2"

NEW CONNECTION TO EXISTING STRAINER.REMOVE AND CLEAN STRAINER SCREEN.

11

11

3 3

2

4

3 3

5

WH-1

1-1/2"

2-1/2"

PROVIDE 208 VAQUASTAT.

WH-2

T-1 T-2

ROUTE TO NEARESTFLOOR DRAIN.

ROUTE TO NEARESTFLOOR DRAIN.

ROUTE TO NEARESTFLOOR DRAIN.

Tyso

n a

nd

Bill

y A

rch

ite

cts

, P

.C.

4000 M

ors

ay D

rive

Rockfo

rd,

IL

61107

(815)

229-8

222

FA

X: (8

15)

229-8

218

Sheet No:

ww

w.tysonandbill

y.c

om

Drn

.A

pp

d.

Pro

ject N

um

be

rD

ate

REVISION DATE

BO

ND

ING

CO

.C

ON

TR

AC

TO

R

OW

NE

RA

RC

HIT

EC

T

M200

DO

ME

ST

IC W

AT

ER

FLO

W D

IAG

RA

MS

SP

EN

CE

R T

OW

ER

BO

ILE

RR

EP

LA

CE

ME

NT

111 2

0T

H S

TR

EE

T R

OC

K IS

LA

ND

, IL

12-9

810

3/2

3/1

7K

EV

MA

GK

EIS

TO

REFERENCE SCALE IN INCHES

0 1 2 3

ENGINEERINGCONSULTANTS 309.788.0673 FAX: 309.786.5967

www.kjww.com

623 26TH AVENUEQUAD CITIES, ILLINOIS 61201

PROJECT #

Illinois Design Firm Registration #184-000973

KJWW ENGINEERING RESERVES PROPRIETARY RIGHTS, INCLUDING COPYRIGHTS,TO THIS DRAWING AND THE DATA SHOWN THEREON. SAID DRAWING AND/OR DATAARE THE EXCLUSIVE PROPERTY OF KJWW ENGINEERING AND SHALL NOT BE USEDOR REPRODUCED FOR ANY OTHER PROJECT WITHOUT THE EXPRESS WRITTENAPPROVAL AND PARTICIPATION OF KJWW ENGINEERING. © 2017 KJWW CORP.

The FUTURE.Built SMARTER.

®

00161450.00

NO SCALE

DOMESTIC HOT WATER FLOW DIAGRAM - DEMOLITION

NO SCALE

DOMESTIC HOT WATER FLOW DIAGRAM

KEYNOTES:1. PROVIDE VACUUM RELIEF VALVE BETWEEN TANK AND VALVE.2. PROVIDE CONDENSATE NEUTRALIZER, REFER TO PLUMBING MATERIAL

LIST UNDER WATER HEATER.3. PIPE SAFETY RELIEF, TANK DRAIN AND CONDENSATE TO FLOOR

DRAIN.4. BALANCE FLOW THRU WATER HEATERS TO MATCH.5. PROVIDE AQUASTAT TO CONTROL STORAGE TANK CIRCULATION PUMP

AND SET TO 130°F (ADJ).6. PIPE CONNECTIONS TO THE WATER HEATERS AND DOMESTIC HOT

WATER STORAGE TANKS SHALL BE REVERSE RETURN AS SHOWN TOEQUALIZE FLOW THROUGH THEM.

1

2

M

M

4"H

WS

4"H

WS

4"H

WS

4"H

WS

4"HWR

P-EP-EP-E

REFER TO DOMESTIC WATER FLOWDIAGRAM 2/201 FORCONTINUATION.

AS-E

PRV-E

BFP-E PRV-E

ET-E

P

HEATING RETURN

BLR-E (DHW)

EXISTING BYPASS(POT)FEEDER.

SYSTEM PUMP P-E

SYSTEM PUMP P-E

ET-E

HEATING SUPPLY

ET-E

HX-E HX-E

4"HWR

4"HWS

1/2"NCW

DHW(DOMESTIC HOT

WATER)

DHW

P-E

T

3"H

WS

3"H

WR3"H

WS

3"H

WR

BLR-E

T

FS

BLR-E

T

FS

3"H

WS

3"H

WR

BLR-E

T

FS

PP

PP

4"G 4"G

2"G

2"G 2"G

6"H

WS

6"H

WS

6" DECOUPLER

4"G 4"G

3"H

WR

3"H

WR

3"H

WR

6"HWR

3"H

WS

FS

3"H

WS

FS

3"H

WS

P

FS

6"HWS6"HWS

VFD

P

VFD

P

BLR-3BLR-2BLR-1

PUMP P-3

(95 GPM)

PUMP P-2

(95 GPM)

PUMP P-1

(95 GPM)

PUMP P-4 (390 GPM)

BFP-E

FROM BLDG.

EXISTING BYPASS(POT)FEEDER.

TO BLDG.

REFER TO DOMESTIC WATER FLOWDIAGRAM 2/M200 FOR CONTINUATION

T

AS-1

AIR SEPARATOR. REFERTO SECTION 23 21 00.

AUTOMATIC AIR VENT. REFERTO SECTION 23 21 00.

PUMP P-5 (390 GPM)

RELOCATE CHEMICALPOT FEEDER ANDPROVIDE NEW PIPING.

ET-2 BLADDER EXPANSIONTANK WITH 158 GALLON FULLACCEPTANCE. 50 PSI INITIALPRESSURIZATION.

P P

1"

6" SUCTION & DISCHARGEPIPING (TYP.)

3/4"

3/4"

NEW CONNECTION TOEXISTING 6" VALVE.

NEW CONNECTIONTO 6" HWS. 111

3 3 3

2 (TYP.)

4

(TYP.)6(TYP.)5

DP

DIFFERENTIAL PRESSURETRANSDUCER TOCONTROL P-4 & P-5 VFDSPEEDS.

P

1"

NC 7

8

1"

Tyso

n a

nd

Bill

y A

rch

ite

cts

, P

.C.

4000 M

ors

ay D

rive

Rockfo

rd,

IL

61107

(815)

229-8

222

FA

X: (8

15)

229-8

218

Sheet No:

ww

w.tysonandbill

y.c

om

Drn

.A

pp

d.

Pro

ject N

um

be

rD

ate

REVISION DATE

BO

ND

ING

CO

.C

ON

TR

AC

TO

R

OW

NE

RA

RC

HIT

EC

T

M201

HE

AT

ING

WA

TE

R F

LO

W D

IAG

RA

MS

SP

EN

CE

R T

OW

ER

BO

ILE

RR

EP

LA

CE

ME

NT

111 2

0T

H S

TR

EE

T R

OC

K IS

LA

ND

, IL

12-9

810

3/2

3/1

7K

EV

MA

GK

EIS

TO

REFERENCE SCALE IN INCHES

0 1 2 3

ENGINEERINGCONSULTANTS 309.788.0673 FAX: 309.786.5967

www.kjww.com

623 26TH AVENUEQUAD CITIES, ILLINOIS 61201

PROJECT #

Illinois Design Firm Registration #184-000973

KJWW ENGINEERING RESERVES PROPRIETARY RIGHTS, INCLUDING COPYRIGHTS,TO THIS DRAWING AND THE DATA SHOWN THEREON. SAID DRAWING AND/OR DATAARE THE EXCLUSIVE PROPERTY OF KJWW ENGINEERING AND SHALL NOT BE USEDOR REPRODUCED FOR ANY OTHER PROJECT WITHOUT THE EXPRESS WRITTENAPPROVAL AND PARTICIPATION OF KJWW ENGINEERING. © 2017 KJWW CORP.

The FUTURE.Built SMARTER.

®

00161450.00

NO SCALE

HEATING WATER FLOW DIAGRAM - DEMOLITION

NO SCALE

HEATING WATER FLOW DIAGRAM

NOTES:1. REMOVE EXISTING BOILER AND ALL ASSOCIATED PUMPS, PIPING AND

CONTROLS.2. PROVIDE EQUIPMENT AND PIPING COORDINATION DRAWINGS FOR A/E

APPROVAL BEFORE BEGINNING WORK. REFER TO SECTION 23 05 00.3. NEATLY ROUTE ALL DRAIN PIPING TO THE NEAREST FLOOR DRAIN.

COORDINATE ROUTING WITH A/E TO MAXIMIZE ACCESS AND AVOID TRIPHAZARDS.

KEYNOTES:1. PRESSURE GAUGE WITH SNUBBER PER SECTION 23 09 13. PROVIDE

SINGLE GAUGE WITH 3/8" FLEXIBLE COPPER TUBING, BALL VALVES ANDTAPS AS SHOWN ON DIAGRAM.

2. FLOW SWITCH AND PRESSURE/TEMPERATURE GAUGE PROVIDED BYBOILER MANUFACTURER, INSTALLED BY MECHANICAL CONTRACTOR.WIRE FLOW SWITCH TO BOILER CONTROL PANEL.

3. INSTALL SAFETY RELIEF VALVE PROVIDED BY BOILER MANUFACTURER.PIPE FULL-SIZE TO DRAIN. SUPPORT SOLIDLY.

4. SYSTEM TEMPERATURE SENSOR PROVIDED BY BOILER MANUFACTURER,WIRED TO BOILER CONTROL PANELS.

5. ROUTE 3/4" BOILER GAS VENT PIPING TO OUTDOORS.6. PROVIDE NEUTRALIZER FOR BOILER AND FLUE CONDENSATE AND ROUTE

TO FLOOR DRAIN. NEUTRALIZER SHALL BE JJM BOILER MODEL JM-50. ALLCONDENSATE DRAIN PIPING SHALL BE SCH. 40 316 STAINLESS STEEL.

7. PRESSURE REGULATING AND MAKE-UP WATER VALVE. SET AT 50 PSIGDISCHARGE PRESSURE. REFER TO SECTION 23 21 00 FORSPECIFICATIONS.

8. PRESSURE RELIEF VALVE. SET AT 100 PSIG. REFER TO SECTION 23 21 00FOR SPECIFICATIONS.

2

1

S

6"HWS

6"HWS

6" DECOUPLER

6"HWR

HW

R

HW

R

HW

R

HW

S

HW

S

HW

S

FS

BLR-2BLR-3 BLR-1

P-5

P-3

FS

FS

P-2 P-1

LWT

EWT

111LWT

EWT

LWT

EWT

WIRING. (TYP.)

PROVIDE OATEMP SENSOR

2 2 2

3

MASTERBOILER

CONTROLLER

ON/OFFON/OFFON/OFF

BOILER OPERATION:HEATING WATER SYSTEM WILL HAVE THREE GAS-FIRED CONDENSING BOILERS AND PRIMARY/SECONDARYCONFIGURATION. HEATING WATER BOILERS SHALL HAVE UNIT MOUNTED CONTROLS AND A BOILER MANAGEMENTCONTROL PANEL PROVIDED BY THE BOILER MANUFACTURER OR UNIT MOUNTED CONTROLS THAT ARE ABLE TO BEDESIGNATED AS A MASTER CONTROLLER.

SEQUENCE OF OPERATION:WHEN BOILER MASTER CONTROLLER IS ENABLED IT SHALL ENABLE THE LEAD BOILER, OPEN THE ASSOCIATED TWO-POSITION ISOLATION VALVE, AND ENERGIZE THE ASSOCIATED PRIMARY PUMP AND ENABLE THE SECONDARY SYSTEMPUMP. ONLY ONE SECONDARY PUMP SHALL RUN AT A TIME, START/STOP AND SWITCHING BETWEEN LEAD AND LAGPUMP SHALL BE CONTROLLED THRU SECONDARY PUMP CONTROL PANEL.

BOILER CONTROLLER SHALL MODULATE BURNER FIRING RATE AS REQUIRED TO MAINTAIN THE SYSTEM HEATINGWATER SUPPLY TEMPERATURE SETPOINT. THE BOILER MANAGEMENT CONTROL PANEL SHALL MAINTAIN THE SYSTEMHEATING WATER SUPPLY TEMPERATURE WITHIN +/- 5°F (ADJ.). THE MASTER BOILER MANAGEMENT CONTROL PANELCAN STAGE ON MULTIPLE BOILERS AT PART LOAD TO INCREASE THE EFFICIENCY OF THE PLANT.

MASTER BOILER CONTROLLER SHALL RESET HEATING WATER SUPPLY TEMPERATURE BASED ON OA TEMPERATURERESET SCHEDULE.

SECONDARY CONTROL PANEL SHALL AUTOMATICALLY ENABLE THE LAG HEATING WATER PUMP TO RUN IN THE EVENTTHE LEAD HEATING WATER PUMP FAILS TO OPERATE.

ALARMS, INTERLOCKS & SAFETIES:MC SHALL COORDINATE ALL SAFETY AND INTERLOCK REQUIREMENTS WITH BOILER MANUFACTURER. MC SHALLCOORDINATE AND PROVIDE THE INSTALLATION AND WIRING OF BOILER WATER DIFFERENTIAL PRESSURE/FLOWSWITCHES AND OTHER COMPONENTS PROVIDED WITH THE BOILER AS REQUIRED FOR PROPER OPERATION. MC SHALLPROVIDE AND TERMINATE ALL SAFETY AND INTERLOCK WIRING WITH BOILER CONTROL PANELS AS REQUIRED.

0 10 20 30 40 50 60 70 80

120

130

140

150

160

170

180

HW

S T

EM

P °

F

OUTSIDE AIR TEMP °F

HEATING WATER SUPPLY TEMPERATURERESET SCHEDULE

VFD

P-4VFD

DPS DPS

4

5

PROVIDE SYSTEM CONTROL PANEL, MODULATING DAMPER AT EACHBOILER, SENSORS AND WIRING AS SPECIFIED IN SECTION 23 51 00.

SEQUENCE OF OPERATION:

EACH DAMPER CIRCUIT SHALL BE INDEPENDENT OF EACH OTHERAND ENERGIZED BY AN OUTPUT FROM THE ASSOCIATED BOILER. THEDAMPER SHALL RECEIVE A SIGNAL FROM THE BOILER WHEN A CALLFOR HEAT IS REQUIRED. THE SIGNAL SHALL TRIGGER THE DAMPERTO OPEN AND TRIP A LIMIT SWITCH BUILT INTO THE ACTUATORWHICH SENDS A SIGNAL BACK TO THE BOILER PROVING IT IS OPEN.THE LIMIT SWITCH FOR DAMPER POSITION SHALL BE ADJUSTABLEAND SET DURING START-UP.

WITH A PROVEN OPEN DAMPER THE BOILER WILL START ITS PRE-PURGE CYCLE. AN ADJUSTABLE TIMING RELAY INCORPORATED INTHE DAMPER CONTROL WILL HOLD THIS DAMPER POSITION DURINGTHE BOILER PRE-PURGE CYCLE.

ONCE THE BOILER IS RUNNING THE DAMPER IS RELEASED FOR FULLMODULATION READING THE OUTLET PRESSURE AT THE BOILER ANDMODULATING THE DAMPER POSITION ACCORDINGLY. THE DAMPERCAN HAVE DIFFERENT PRESSURE SETTINGS DEPENDING ON THENEEDS OF THE SYSTEM OR FOR DIFFERENT BOILERS COMBINED INTHE SAME VENTING SYSTEM.

WHEN A BOILER SHUTS DOWN, THE DAMPER SHALL RETURN TO THECLOSED POSITION. EACH DAMPER SHALL BE SET TO A NORMALLYCLOSED POSITION TO PROHIBIT DRAFT THROUGH UNFIRED BOILERS.THE DAMPER CONTROL SHALL BE SET FOR A SAFETY POSITION OFFULLY CLOSED. IF THE SYSTEM HAS A FAILURE, THE DAMPER SHALLSPRING CLOSED AND SHUT DOWN THE BOILER.

DRAFT CONTROL MANUFACTURER'S REPRESENTATIVE SHALL BERESPONSIBLE FOR ENSURING THE DRAFT CONTROL SYSTEM ISPROPERLY INSTALLED. THE REPRESENTATIVE SHALL MAKE ALLNECESSARY SETTINGS FOR PROPER BOILER OPERATION ANDPERFORM COMPLETE START-UP OF THE SYSTEM.

DRAFTCONTROL

PANEL

ACT ACT ACT

BOILER FLUEMODULATINGDAMPER. (TYP.)

BLR-1 BLR-2 BLR-3

Tyso

n a

nd

Bill

y A

rch

ite

cts

, P

.C.

4000 M

ors

ay D

rive

Rockfo

rd,

IL

61107

(815)

229-8

222

FA

X: (8

15)

229-8

218

Sheet No:

ww

w.tysonandbill

y.c

om

Drn

.A

pp

d.

Pro

ject N

um

be

rD

ate

REVISION DATE

BO

ND

ING

CO

.C

ON

TR

AC

TO

R

OW

NE

RA

RC

HIT

EC

T

M300

CO

NT

RO

L D

IAG

RA

MS

SP

EN

CE

R T

OW

ER

BO

ILE

RR

EP

LA

CE

ME

NT

111 2

0T

H S

TR

EE

T R

OC

K IS

LA

ND

, IL

12-9

810

3/2

3/1

7K

EV

MA

GK

EIS

TO

REFERENCE SCALE IN INCHES

0 1 2 3

ENGINEERINGCONSULTANTS 309.788.0673 FAX: 309.786.5967

www.kjww.com

623 26TH AVENUEQUAD CITIES, ILLINOIS 61201

PROJECT #

Illinois Design Firm Registration #184-000973

KJWW ENGINEERING RESERVES PROPRIETARY RIGHTS, INCLUDING COPYRIGHTS,TO THIS DRAWING AND THE DATA SHOWN THEREON. SAID DRAWING AND/OR DATAARE THE EXCLUSIVE PROPERTY OF KJWW ENGINEERING AND SHALL NOT BE USEDOR REPRODUCED FOR ANY OTHER PROJECT WITHOUT THE EXPRESS WRITTENAPPROVAL AND PARTICIPATION OF KJWW ENGINEERING. © 2017 KJWW CORP.

The FUTURE.Built SMARTER.

®

00161450.00

NO SCALE

HEATING WATER CONTROL DIAGRAM1

NOTES:1. M.C. SHALL PROVIDE ALL CONTROLS AND WIRING REQUIRED TO STAGE

AND CONTROL ALL BOILERS AND ASSOCIATED PRIMARY PUMPS INACCORDANCE WITH THE BOILER MFR'S RECOMMENDATIONS.

2. M.C. SHALL PROVIDE DIFFERENTIAL PRESSURE TRANSDUCERS ANDASSOCIATED WIRING TO THE VFDs FOR PUMPS P-5 AND P-6 TOMODULATE THE SPEED OF THE PUMPS. THE INITIAL DIFFERENTIALSETPOINT SHALL BE 10 PSIG, BUT THE M.C. SHALL VERIFY THE REQUIREDDIFFERENTIAL PRESSURE SETPOINT REQUIRED TO SATISFY THE MOSTREMOTE HEATING UNITS.

3. M.C. SHALL PROVIDE BOILER DRAFT CONTROLS AS SPECIFIED IN SECTION23 51 00 IN ACCORDANCE WITH MFR'S RECOMMENDATIONS INCLUDING ALLASSOCIATED WIRING.

4. ALL CONTROL WIRING SHALL BE INSTALLED IN CONDUIT.

KEYNOTES:1. PROVIDE WIRING BETWEEN EACH BOILER CONTROL PANEL, FLOW

SWITCHES, EXTERNAL SENSORS AND PRIMARY PUMPS.2. BOILER PUMP START/STOP. CONTROL THROUGH INDIVIDUAL BOILER

PANEL.3. PROVIDE TEMPERATURE SENSOR TO CONTROL BOILERS.4. PROVIDE SEPARATE DIFFERENTIAL PRESSURE TRANSDUCERS TO

CONTROL PUMPS P-4 AND P-5.5. COORDINATE THE PLACEMENT OF THE OUTSIDE AIR SENSOR WITH THE

A/E. LOCATE IN A SHADED LOCATION NEAR ENTRY CANOPY.

NO SCALE

BOILER DRAFT CONTROL2

ELECTRICAL ABBREVIATION KEY

AFF ABOVE FINISHED FLOOR

N.C. NORMALLY CLOSED

NIC NOT IN CONTRACT

N.O. NORMALLY OPEN

N/A NOT APPLICABLE

ABBR: DESCRIPTION:

TYP TYPICAL

C CONDUIT

UNO UNLESS NOTED OTHERWISE

1. ##-### INDICATES ELECTRICAL EQUIPMENT DEFINED IN ELECTRICAL SCHEDULES ORSPECIFICATION. REFER TO DRAWINGS CONTAINING ELECTRICAL SCHEDULES.PERMANENT NAMEPLATE SHALL MATCH FINAL EQUIPMENT NOMENCLATURE, NOTELECTRICAL EQUIPMENT TAG NAME, REFER TO SPECIFICATIONS.

LUMINAIRE KEY:

DEVICE KEY:

ELECTRICAL GENERAL NOTES:

LUMINAIRE

F1 = FIXTURE TAG1 = CIRCUIT NUMBERa = SWITCH DESIGNATION

*IF LABEL IS ORIENTED HORIZONTALLY A SLASH WILL SEPARATE THISINFORMATION. EX: F1 / 1 / a / NL

DEVICE+##" = MOUNTING (IF APPLICABLE)1 = CIRCUIT NUMBER

*IF LABEL IS ORIENTED HORIZONTALLY A SLASH WILL SEPARATE THISINFORMATION. EX: +##" / 1

1. THE COMPLETE INSTALLATION SHALL BE IN ACCORDANCE WITH THE ADA STANDARDSFOR ACCESSIBLE DESIGN. REFER TO THE ADA GUIDELINES FOR ALL CONFIGURATIONSDETAIL ON THIS PAGE FOR ADDITIONAL INFORMATION.

2. CIRCUIT NUMBERS ARE SHOWN FOR CIRCUIT IDENTIFICATION. CIRCUITING SHALLAGREE WITH NUMBERING ON THE PANEL PROVIDED. COMMON NEUTRALS MAY NOT BEUSED FOR BRANCH CIRCUITS. BALANCE THE LOAD ON PANEL AS EVENLY AS POSSIBLEBETWEEN EACH PHASE.

3. CIRCUITS SERVING EMERGENCY AND EXIT LUMINAIRES WILL BE RUN IN A SEPARATERACEWAY FROM ALL OTHER CIRCUITS.

4. FLUSH MOUNT ALL LIGHTING CONTROL DEVICES AT +42" FROM FLOOR (CENTERLINEDIMENSION), EXCEPT WHERE OTHERWISE NOTED. DEVICES MAY BE SURFACEMOUNTED WHEN CONDUIT IS SPECIFIED EXPOSED.

5. FLUSH MOUNT ALL DUPLEX RECEPTACLES AND TECHNOLOGY OUTLETS AT +18" FROMFLOOR (CENTERLINE DIMENSION), EXCEPT WHERE OTHERWISE NOTED. RECEPTACLESAND OUTLETS MAY BE SURFACE MOUNTED WHEN CONDUIT IS SPECIFIED EXPOSED.

6. ALL MATERIALS USED TO SEAL PENETRATIONS OF FIRE RATED WALLS AND FLOORSSHALL BE TESTED AND CERTIFIED AS A SYSTEM PER ASTM E814 STANDARDS FOR FIRETESTS OF THROUGH-PENETRATION FIRESTOPS.

7. CONTRACTOR SHALL COORDINATE THE LOCATION OF ALL LUMINAIRES WITH NEW ANDEXISTING DEVICES, EQUIPMEN, PIPING, DUCTWORK ETC.

8. CONTRACTOR SHALL VERIFY ALL EXISTING AND NEW EQUIPMENT LOCATIONS WITHPLANS, ELEVATIONS, AND REVIEWED SHOP DRAWINGS. PRIOR TO MAKING THEACTUAL ELECTRICAL INSTALLATION, THIS CONTRACTOR SHALL ADJUST, LUMINAIRES,OUTLETS, OR CONNECTION LOCATIONS TO ACCOMMODATE EQUIPMENT.

9. ELECTRICAL EQUIPMENT SHALL BE MOUNTED TO AVOID IMPEDANCE OF, OPERATIONOF, AND/OR ACCESS TO ELECTRICAL AND MECHANICAL EQUIPMENT. ALL MOUNTING OFELECTRICAL AND EQUIPMENT, ON EQUIPMENT SUPPLIED BY ANOTHER CONTRACTOR,SHALL BE APPROVED IN ADVANCE BY THE OTHER CONTRACTOR.

10. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL OPENINGS REQUIRED IN WALLS. ALLOPENINGS SHALL BE REPAIRED TO MATCH EXISTING BY A QUALIFIED CONTRACTOR ATTHE EXPENSE OF THIS CONTRACTOR. ALL CONDUITS THROUGH WALLS SHALL BEGROUTED OR SEALED INTO OPENINGS.

11. CONTRACTOR SHALL REMOVE AND REINSTALL ALL CEILING TILES AS REQUIRED FORTHE EXECUTION OF ELECTRICAL WORK. CONTRACTOR SHALL REPLACE CEILING TILESWITH IDENTICAL MATERIAL WHERE DAMAGED BY THIS CONTRACTOR.

ELECTRICAL INSTALLATION NOTES:

VFD-# VARIABLE FREQUENCY DRIVE - REFER TO VFD SCHEDULE 26 29 23

N/A N/A FIRE ALARM ADDRESSABLE MONITOR MODULE(EXISTING)

MM

N/A N/A FIRE ALARM FLOW SWITCH TO MONITOR FIREPROTECTION SYSTEM (EXISTING)

FS

N/A N/A FIRE ALARM MONITOR SWITCH TO MONITORFIRE PROTECTION SYSTEM (EXISTING)

MS

CO N/A CARBON MONOXIDE DETECTOR (EXISTING)N/A

XM# EMERGENCY UNIT26 51 00

FIRE ALARM AUDIO/VISUAL NOTIFICATIONDEVICE - CEILING MOUNTED (EXISTING)

FIRE ALARM HEAT DETECTOR (EXISTING)H

26 24 19FCS-# FUSIBLE COMBINATION STARTER, REFER TO DISCONNECT AND STARTERSCHEDULE

26 24 19MS-# MANUAL STARTER, REFER TO DISCONNECT AND STARTER SCHEDULE

26 24 19MX-# MANUAL SWITCH, REFER TO DISCONNECT AND STARTER SCHEDULE

R-# RELAY 26 09 16

SW-1P 26 27 26 SWITCH - SINGLE POLE (EXISTING/DEMOLITION)

N/A N/A FUSED SWITCH (EXISTING/DEMOLITION)F

F# INDUSTRIAL/STRIP LIGHT LUMINAIRE26 51 00

DISCONNECT SWITCH

ELECTRICAL EQUIPMENT TAGS

TAG: DESCRIPTION:RELATED

SPECIFICATION

F# LUMINAIRE TYPE 26 51 00

JB 26 05 33 JUNCTION BOXJ

J

ECONN 26 05 33 ELECTRICAL CONNECTIONE

E

PANELBOARD - SURFACE MOUNT

ES ES 26 09 16 EMERGENCY STOP, N.C. CONTACT

FCS-# 26 24 19 COMBINATION STARTER

DUPLEX RECEPTACLE, 125V (EXISTING)

ELECTRICAL SYMBOL LIST

SYMBOL: TAG:SPEC

SECTION:DESCRIPTION:

MX-#/MS-# 26 24 19 MANUAL SWITCH / STARTER

N/A N/A

N/A N/A

N/A N/A

N/A N/A

N/A N/A

FDS-# 26 28 16

26 24 19FDS-# FUSIBLE DISCONNECT SWITCH, REFER TO DISCONNECT AND STARTERSCHEDULE

X

EXISTING INDUSTRIAL/STRIP LIGHT LUMINAIRE

AV

TC-# TIME CLOCK CONTROL 26 09 16

SW-3W 26 27 26 SWITCH - 3 WAY

3

ELECTRICAL PHASING NOTES:THESE NOTES APPLY TO ALL ELECTRICAL SHEETS AND TRADES, INCLUDING BUT NOTLIMITED TO, LIGHTING, POWER, AND SYSTEMS.

1. REFER TO [ARCHITECTURAL] DRAWINGS FOR GENERAL DESCRIPTION OF PHASES.REFER TO [CONSTRUCTION MANAGER/GENERAL CONTRACTOR/ARCHITECTS]INSTRUCTIONS FOR MORE DETAILS, PHASING SCHEDULES AND FORCONCURRENT WORK. MECHANICAL, ELECTRICAL AND TECHNOLOGY DRAWINGSDEPICT THE INTENT OF THE FINAL DESIGN. THE MECHANICAL, ELECTRICAL, ANDTECHNOLOGY DRAWINGS DO NOT DEPICT THE MEANS AND METHODS TO MEET THEREQUIREMENTS OF THE PHASING CRITERIA.

2. REVIEW PROJECT PHASING PLANS TO COORDINATE DEMOLITION WORK, OUTAGES,ETC. WITH AFFECTED ADJACENT AREAS.

3. PROVIDE TEMPORARY LIGHTING, POWER AND SYSTEMS, ETC. AS NEEDED TOMAINTAIN SERVICE TO ALL AREAS DURING ALL PHASES OF PROJECT.

4. INSTALL TEMPORARY LIGHTING, CIRCUITS, ETC. AS NECESSARY TO KEEP ALLOCCUPIED SPACES OPERATIONAL THROUGHOUT ALL PHASES OF THE PROJECT

5. PHASE DEMOLITION WORK TO MINIMIZE DOWNTIME.

PLAN OR DETAIL NUMBER

PLAN OR DETAIL NAME

PLAN OR DETAIL SCALE

DETAIL REFERRED TO BY SECTION CUT

SHEET DETAIL IS LOCATED ON

NAME

1VIEW NAME1/8" = 1'-0"

1

M101

14

32

T101

SIMDETAIL REFERRED TO BY ELEVATION

SHEET DETAIL IS LOCATED ON

INDICATES SIMILAR DETAILREFERENCED IN MULTIPLE LOCATIONS

SIM

INDICATES SIMILAR DETAILREFERENCED IN MULTIPLE LOCATIONS

LEVEL NAME

10' - 0" HEIGHT ABOVEPROJECT 0' - 0"

1 INDICATES NOTE USED TO DESCRIBEADDITIONAL INFORMATION ABOUTWORK REQUIRED, SPECIFIC TO THESHEET AND/OR DETAIL

NO R HT

INDICATES DIRECTION OF TRUE NORTH

VIEW KEY

LINE TYPE KEY:

NEW WORK BY THIS CONTRACTOR(DARK SOLID LINE)

NEW WORK UNDERFLOOR OR UNDERGROUND BY THIS CONTRACTOR(DARK LONG DASHED LINE)

NEW WORK BY OTHERS AND/OR EXISTING TO REMAIN(LIGHT SOLID LINE)

EXISTING TO BE REMOVED BY THIS CONTRACTOR(DARK SHORT DASHED LINE)

TEMPERATURE CONTROLS CONTRACTORT.C.C.

HEATING CONTRACTORH.C.

PLUMBING CONTRACTORP.C.

GENERAL CONTRACTORG.C.

MECHANICAL CONTRACTORM.C.

VENTILATION CONTRACTORV.C.

ELECTRICAL CONTRACTORE.C.

CONTRACTOR ABBREVIATION KEY

ABBR: DESCRIPTION:

BUILDING CODE: IBC 2009 EDITION

FIRE CODE: IFC 2009 EDITION

PLUMBING CODE: ILLINOIS PLUMBING CODE CURRENT EDITION

MECHANICAL CODE: IMC 2009 EDITION

ELECTRICAL CODE: NFPA 70 (NEC) 2008 EDITION

LIFE SAFETY CODE: NFPA 101 2000 EDITION

ENERGY CONSERVATION CODE: IECC 2015

LOCAL BUILDING CODE: CURRENT EDITION

APPLICABLE CODES

CONTRACTOR SHALL COMPLY WITH APPLICABLE CODES AND LOCAL AMENDMENTS.

1. EXISTING CONDITIONS ARE SHOWN BASED ON INFORMATION OBTAINED FROM FIELDSURVEYS, EXISTING BUILDING DOCUMENTS, AND STAFF. VERIFY EXISTING CONDITIONSAND REPORT ANY CONFLICTS BEFORE PROCEEDING.

2. NOT ALL EXISTING EQUIPMENT, LUMINAIRES, AND CONDUIT ARE SHOWN. VERIFYEXISTING CONDITIONS AND REPORT ANY CONFLICTS WITH NEW WORK BEFORESTARTING WORK.

3. FIELD VERIFY THE AVAILABLE CLEARANCES FOR WIREWAYS AND CONDUITS BEFOREFABRICATION. RISES AND DROPS MAY BE NECESSARY BECAUSE OF EXISTING FIELDCONDITIONS.

4. EACH CONTRACTOR SHALL FIELD VERIFY ACCESSIBILITY TO THE AREA OF HIS WORKAND SHALL NOTIFY THE ARCHITECT/ENGINEER PRIOR TO BIDDING IF OTHER UTILITIESARE REQUIRED TO BE REMOVED OR RELOCATED TO ALLOW ACCESS TO HIS AREA OFWORK.

5. EACH CONTRACTOR SHALL CUT AND PATCH ROOFS, WALLS, AND FLOORS ASSOCIATEDWITH THEIR WORK.

6. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR REMOVAL AND REPLACEMENT OFCEILINGS, CEILING TILES, AND CEILING GRIDS ASSOCIATED WITH AREAS OF WORK BYALL CONTRACTORS. NOTIFY THE GENERAL CONTRACTOR OF AFFECTED AREAS PRIORTO BIDDING.

7. WHERE EXISTING ELECTRICAL SYSTEMS ARE LOCATED IN AREAS THAT CONFLICT WITHNEW EQUIPMENT, PIPING, OR DUCTWORK TO BE INSTALLED, EACH CONTRACTORSHALL EITHER ARRANGE NEW EQUIPMENT, CONDUIT, OR DUCTWORK IN SUCH AFASHION THAT IT DOES NOT CONFLICT WITH EXISTING SYSTEMS, OR REWORKEXISTING ELECTRICAL SYSTEMS TO ALLOW FOR INSTALLATION OF NEW EQUIPMENT,PIPING, OR DUCTWORK.

ELECTRICAL RENOVATION NOTES:THESE NOTES APPLY TO ALL ELECTRICAL SHEETS AND TRADES, INCLUDING BUT NOTLIMITED TO, LIGHTING, POWER, AND SYSTEMS.

BRANCH CIRCUIT WIRING KEY

WIREID

2 WIRE 3 WIRE 4 WIRE

THHW/THWN COPPERCONDUCTORS

EQUIPMENTGROUNDINGCONDUCTOR CONDUIT

A# 2#12 3#12 4#12 1#12 3/4"

B# 2#10 3#10 4#10 1#10 3/4"

C# 2#8 3#8 4#8 1#10 3/4"

D# 2#6 3#6 4#6 1#10 1"

E# 2#4 3#4 4#4 1#8 1 1/4"

F# 2#2 3#2 4#2 1#8 1 1/4"

G# 2#1 3#1 4#1 1#6 1 1/2"

H# 2#1/0 3#1/0 4#1/0 1#6 2"

ALL BRANCH CIRCUITS SHALL INCLUDE THE EQUIPMENT GROUNDCONDUCTOR

ELECTRICAL SHEET INDEXE000 ELECTRICAL COVER SHEET

E101 LIGHTING FLOOR PLANS

E102 POWER AND SYSTEMS FLOOR PLANS

LC01 LIGHTING CONTACTOR DETAIL

LC02 EXTERIOR LIGHTING CONTROL DETAIL

Tyso

n a

nd

Bill

y A

rch

ite

cts

, P

.C.

4000 M

ors

ay D

rive

Rockfo

rd,

IL

61107

(815)

229-8

222

FA

X: (8

15)

229-8

218

Sheet No:

ww

w.tysonandbill

y.c

om

Drn

.A

pp

d.

Pro

ject N

um

be

rD

ate

REVISION DATE

BO

ND

ING

CO

.C

ON

TR

AC

TO

R

OW

NE

RA

RC

HIT

EC

T

E000

ELE

CT

RIC

AL C

OV

ER

SH

EE

TS

PE

NC

ER

TO

WE

R B

OIL

ER

RE

PLA

CE

ME

NT

111 2

0T

H S

TR

EE

T R

OC

K IS

LA

ND

, IL

12-9

810

3/2

3/1

7D

ON

CR

AJA

RS

CH

REFERENCE SCALE IN INCHES

0 1 2 3

ENGINEERINGCONSULTANTS 309.788.0673 FAX: 309.786.5967

www.kjww.com

623 26TH AVENUEQUAD CITIES, ILLINOIS 61201

PROJECT #

Illinois Design Firm Registration #184-000973

KJWW ENGINEERING RESERVES PROPRIETARY RIGHTS, INCLUDING COPYRIGHTS,TO THIS DRAWING AND THE DATA SHOWN THEREON. SAID DRAWING AND/OR DATAARE THE EXCLUSIVE PROPERTY OF KJWW ENGINEERING AND SHALL NOT BE USEDOR REPRODUCED FOR ANY OTHER PROJECT WITHOUT THE EXPRESS WRITTENAPPROVAL AND PARTICIPATION OF KJWW ENGINEERING. © 2017 KJWW CORP.

The FUTURE.Built SMARTER.

®

00161450.00

[Key*:] REFER TO BRANCH CIRCUIT WIRING KEY ON THIS SHEET FOR CONDUCTOR SIZE AND QUANTITY

Total Amps: 65.48 58.43 65.06

Total Load: 7.75 kVA 7.01 kVA 7.7 kVA

DP-5-41 SPARE 20 A 1 0 0 -- -- SPACE DP-5-42 --

DP-5-39 SPARE 20 A 1 0 0 -- -- SPACE DP-5-40 --

DP-5-37 SPARE 20 A 1 0 0 -- -- SPACE DP-5-38 --

DP-5-35 SPARE 20 A 1 0 0 -- -- SPACE DP-5-36 --

DP-5-33 SPARE 20 A 1 0 0 -- -- SPACE DP-5-34 --

DP-5-31 SPARE 20 A 1 0 0 -- -- SPACE DP-5-32 --

DP-5-29 WH-1, WH-2, *A2 20 A 1 1.2 0 1 20 A SPARE DP-5-30

DP-5-27 SPARE 20 A 1 0 0 1 20 A SPARE DP-5-28

DP-5-25 BOILER VENT DRAFT CONTROL PANEL, *A2 15 A 1 1 0 1 20 A SPARE DP-5-26

-- DP-5-23 -- -- -- 0.45 0 1 20 A SPARE DP-5-24

DP-5-21 CP2, *A3 20 A 2 0.45 0.51 1 20 A CP-1, *A2 DP-5-22

DP-5-19 BOILER SHUTDOWN (EP/RELAYS), *A2 20 A 1 0.1 0.6 1 20 A Lighting, *A2 DP-5-20

-- DP-5-17 -- -- -- 1.12 1.12 -- -- -- DP-5-18 --

-- DP-5-15 -- -- -- 1.12 1.12 -- -- -- DP-5-16 --

DP-5-13 BLR-2, *A3 20 A 3 1.12 1.12 3 20 A BLR-3, *A3 DP-5-14

-- DP-5-11 -- -- -- 0.9 1.12 -- -- -- DP-5-12 --

-- DP-5-9 -- -- -- 0.9 1.12 -- -- -- DP-5-10 --

DP-5-7 P-3' *A3 20 A 3 0.9 1.12 3 20 A BLR-1, *A3 DP-5-8

-- DP-5-5 -- -- -- 0.9 0.9 -- -- -- DP-5-6 --

-- DP-5-3 -- -- -- 0.9 0.9 -- -- -- DP-5-4 --

DP-5-1 P-1, *A3 20 A 3 0.9 0.9 3 20 A P-2, *A3 DP-5-2

CKT NO. LOAD DESCRIPTION

OVERCURRENTPROTECTIONAMPS P

A B COVERCURRENTPROTECTIONP AMPS LOAD DESCRIPTION CKT NO.

Panel Notes:

LOCATION: MECHANICAL EQUIPMENT 114 DEMAND: 22.46 kVA

SCCR: 42,000 WIRE: 4

FED FROM: EDP-19 GROUND BUS PHASE: 3

MOUNTING: SURFACE SOLID NEUTRAL VOLTS: 120/208 Wye

TYPE: BOLT-ON MAIN: 100A MLO

PANEL NAME: DP-5 CONNECTED 22.5 kVA

[Key*:] REFER TO BRANCH CIRCUIT WIRING KEY ON THIS SHEET FOR CONDUCTOR SIZE AND QUANTITY, *E = EXISTING CIRCUIT BREAKER, LOAD AND WIRING; *EB= EXISTING CIRCUIT BREAKER, NEW LOAD, *NB =NEW CIRCUIT BREAKER, NEW LOAD AND WIRING; *RB = REPLACE EXSITING 10,000 AIC RATED CIRCUIT BREAKER WITH NEW 65,000 AIC RATED CIRCUIT BREAKER OF SAME AMPERAGE AS EXISTING

Total Amps: 127.7 120.65 127.28

Total Load: 15.22 kVA 14.48 kVA 15.17 kVA

-- EDP-29 SPACE -- -- 0 0 -- -- SPACE EDP-30 --

-- EDP-27 SPACE -- -- 0 0 -- -- SPACE EDP-28 --

-- EDP-25 SPACE -- -- 0 0 -- -- SPACE EDP-26 --

-- EDP-23 -- -- -- 7.7 3.73 -- -- -- EDP-24 --

-- EDP-21 -- -- -- 7.01 3.73 -- -- -- EDP-22 --

EDP-19 PANEL DP-5, *NB, *F4 20 A 3 7.75 3.73 3 70 A P-5 (REDUNDANT), *NB, *3C EDP-20

-- EDP-17 -- -- -- 0 0 -- -- -- EDP-18 --

-- EDP-15 -- -- -- 0 0 -- -- -- EDP-16 --

EDP-13 BOOSTER PUMPS,*RB 90 A 3 0 0 3 60 A SPARE? (BREAKER ON/NO LOAD DEFINED)... EDP-14

-- EDP-11 -- -- -- 0 0 -- -- -- EDP-12 --

-- EDP-9 -- -- -- 0 0 2 30 A TRASH COMPACTER, *RB EDP-10

EDP-7 PANEL 'DP2'; *E 100 A 3 0 0 -- -- -- EDP-8 --

-- EDP-5 -- -- -- 3.73 0 2 60 A PANEL 'DPE', *RB EDP-6

-- EDP-3 -- -- -- 3.73 0 1 20 A SPARE? (BREAKER ON/NO LOAD DEFINED)... EDP-4

EDP-1 P-4, *3C 60 A 3 3.73 0 1 20 A ENGINE BLOCK HEATER; *E EDP-2

CKT NO. LOAD DESCRIPTION

OVERCURRENTPROTECTIONAMPS P

A B COVERCURRENTPROTECTIONP AMPS LOAD DESCRIPTION CKT NO.

Panel Notes: EXISTING SIEMENS ITE TYPE CDP-7

LOCATION: MAINTENANCE 118 DEMAND: 44.86 kVA

SCCR: 65,000 WIRE: 4

FED FROM: GROUND BUS PHASE: 3

MOUNTING: SURFACE SOLID NEUTRAL VOLTS: 120/208 Wye

TYPE: BOLT-ON MAIN: 400A/MCB

PANEL NAME: EDP (EXISTING) CONNECTED 44.9 kVA

420 - 4-20mA FOLLOWER

PN - 3-15 PSI TRANSDUCER

CONTROL: MOL - MULTIPLE MOTOR OVERLOADS HAR - PASSIVE HARMONIC FILTER

CB - CIRCUIT BREAKER TO - MELTING THERMAL OVERLOADS LR - INPUT LINE REACTOR

FDS - FUSED DISCONNECT SWITCH *HA - HAND-OFF-AUTO DOOR SWITCH RFT - REMOTE FAULT TRIP

DS - DISCONNECT SWITCH *CT - CONTROL TRANSFORMER, FUSED, 120V RDR - REMOTE DRIVE RUN

LINE DISCONNECT: *ET - ELECTRONIC THERMAL OVERLOADS RSS - REMOTE START-STOP

18PWM - 18 PULSE PWM *MA - MANUAL SPEED ADJUSTMENT *SHZ - SKIP FREQUENCY CAPABILITY

12PWM - 12 PULSE PWM (INCLUDES * ITEMS) ISO - ISOLATION TRANSFORMER

PWM - PULSE WIDTH MODULATED SA - STANDARD ACCESSORIES TA - TWO CONVERTIBLE AUXILIARY CONTACTS

LINE DISCONNECT: REMARKS:

E - VARIABLE FREQUENCY DRIVE SCHEDULE

ITEM LINE DISC.DRIVE

BYPASS CONTROL

VOLTAGE DRIVE

NEMA ENCLOSURE REMARKS APPROVED MANUFACTURERSINPUT OUTPUT PH.H.P.

RATING TYPE

VFD-10 CB N/A 420 208 V 208 V 3 10 PWM 1 SA,LR,VARIABLETORQUE

ABB ACH 550 SERIESTOSHIBA Q9 SERIESDANFOSS VLT6000 SERIES

FS - FUSED SWITCH

MX - MANUAL SWITCH HL - HANDLE PADLOCK HASP

MS - MANUAL STARTER S/N - INSULATED NEUTRAL ASSEMBLY SS - START-STOP PUSHBUTTON IN DOOR

FV - FULL VOLTAGE *TA - TWO CONVERTIBLE AUXILIARY CONTACTS EI - ELECTRICAL INTERLOCK (2)-N.O. & (2)-N.C.

STARTER TYPE: *RP - RED PILOT LIGHT IN DOOR FA - 4-CONVERTIBLE AUXILIARY CONTACTS

*HA - HAND-OFF-AUTO IN DOOR GP - GREEN (OFF) PILOT LIGHT IN DOOR

CB - CIRCUIT BREAKER *EO - ELECTRONIC OVERLOAD TS - 2 SPEED SELECTOR SWITCH IN DOOR

NF - NON-FUSED *CT - CONTROL TRANSFORMER, FUSED 120V TO - MELTING THERMAL OVERLOADS

FU - FUSED SA - STANDARD ACCESSORIES (INCLUDES * ITEMS) PF - PHASE FAILURE RELAY (5 HP OR GREATER)

DISCONNECT TYPE: REMARKS:

NOTE: ALL DISCONNECTS (EXCEPT MANUAL STARTERS) SHALL BE HEAVY DUTY TYPE.

E - DISCONNECT AND STARTER SCHEDULE

ITEM

DISCONNECT TYPE &RATING CIRCUIT

VOLTAGE POLES

STARTER NEMAENCLOSURE REMARKS APPROVED MANUFACTURERSTYPE RATING NEMA SIZE TYPE

FCS-1A FU 30 A 208 V 3 1 FV 1 SA, FUSED AT 10 AMPS SQUARE D 8538 SCG32EATON TYPE ECNGENERAL ELECTRIC CR308SIEMENS CLASS 17

FDS-30A FU 30 A 208 V 3 1 FUSED AT 15 AMPS SQUARE D 3110 H321NEATON TYPE DHGENERAL ELECTRIC TYPE THSIEMENS TYPE HF

MS-1 16 A 120 V 1 0 MS 1 RP, TO, HL SQUARE D 2510 FG5PCUTLER-HAMMER TYPE MSGENERAL ELECTRIC CR101SIEMENS TYPE SMF

MS-2 16 A 208 V 2 0 MS 1 RP,TO,HL SQUARE D 2510 FG6PEATON TYPE MSGENERAL ELECTRIC CR101SIEMENS TYPE SMF

MX-1 30 A 120 V 1 0 MX 1 SQUARE D 2510 KG1EATON TYPE B2GENERAL ELECTRIC TYPE TCSIEMENS TYPE MMS

NOTE: VFD MUST BE PROVIDED WITH PID CONTROLS WITHALL COMPONENTS AND ACCESSORIES REQUIRED TO ALTERNATE PUMP RUN TIMES AND PROHIBIT BOTH PUMPSFROM RUNNING SIMULTANEOUSLY. CIRCUIT BREAKER SHALL BE RATED AT 42,000 AIC.

MAIL ROOM102

MECHANICAL

EQUIPMENT114

STORAGE115

CORRIDOR117

F1 /DP-5-20 /a

3/a 3/a

PANEL 'DP-5'

F1 /DP-5-20 /a

F1 /DP-5-20 /a F1 /DP-5-20 /a

F1 /DP-5-20 /a F1 /DP-5-20 /a

F1DP-5-20a

F1DP-5-20a

F1DP-5-20a

F1DP-5-20a

F1DP-5-20a

F1DP-5-20a

11

MAIL ROOM102

MECHANICAL

EQUIPMENT114

STORAGE115

CORRIDOR117

X X X X

X X X X

X

X

X

X

X

X

X

X

Tyso

n a

nd

Bill

y A

rch

ite

cts

, P

.C.

4000 M

ors

ay D

rive

Rockfo

rd,

IL

61107

(815)

229-8

222

FA

X: (8

15)

229-8

218

Sheet No:

ww

w.tysonandbill

y.c

om

Drn

.A

pp

d.

Pro

ject N

um

be

rD

ate

REVISION DATE

BO

ND

ING

CO

.C

ON

TR

AC

TO

R

OW

NE

RA

RC

HIT

EC

T

E101

LIG

HT

ING

FLO

OR

PLA

NS

SP

EN

CE

R T

OW

ER

BO

ILE

RR

EP

LA

CE

ME

NT

111 2

0T

H S

TR

EE

T R

OC

K IS

LA

ND

, IL

12-9

810

3/2

3/1

7D

ON

CR

AJA

RS

CH

REFERENCE SCALE IN INCHES

0 1 2 3

ENGINEERINGCONSULTANTS 309.788.0673 FAX: 309.786.5967

www.kjww.com

623 26TH AVENUEQUAD CITIES, ILLINOIS 61201

PROJECT #

Illinois Design Firm Registration #184-000973

KJWW ENGINEERING RESERVES PROPRIETARY RIGHTS, INCLUDING COPYRIGHTS,TO THIS DRAWING AND THE DATA SHOWN THEREON. SAID DRAWING AND/OR DATAARE THE EXCLUSIVE PROPERTY OF KJWW ENGINEERING AND SHALL NOT BE USEDOR REPRODUCED FOR ANY OTHER PROJECT WITHOUT THE EXPRESS WRITTENAPPROVAL AND PARTICIPATION OF KJWW ENGINEERING. © 2017 KJWW CORP.

The FUTURE.Built SMARTER.

®

00161450.00

NO R HT

1/4" = 1'-0"1FIRST FLOOR PLAN - LIGHTING

KEYNOTES:

1. SURFACE MOUNT SWITCHES ON EXISTINGSTRUCTURE. COORDINATE EXACT LOCATION WITHEXISTING PIPING.

E#

SHEET NOTES:

1. REFER TO SHEET E000 FOR GENERAL ELECTRICALNOTES, ELECTRICAL INSTALLATION NOTES,RENNOVATION NOTES, ELECTRICAL SYMBOLS LIST,AND PANEL SCHEDULES.

2. COORDINATE NEW LIGHT FIXTURE LOCATIONS WITHNEW AND EXISTING PIPING, DUCTWORK, DEVICES ANDEQUIPMENT.

NO R HT

1/4" = 1'-0"2FIRST FLOOR PLAN DEMOLITION - LIGHTING

ALL LAMPS FOR THIS PROJECT SHALL BE FURNISHED AND INSTALLED BY THE ELECTRICAL CONTRACTOR UNLESS OTHERWISE NOTED.LED LAMP CORRELATED COLOR TEMPERATURE 4000°K, COLOR RENDERING INDEX (CRI) AT OR ABOVE 85, UNLESS NOTED OTHERWISE.

CATALOG NUMBER SHALL NOT BE CONSIDERED COMPLETE AND MATERIAL SHALL NOT BE ORDERED BY MANUFACTURER AND CATALOG NUMBER ONLY. THE COMPLETE DESCRIPTION ANDTHE SPECIFICATION SHALL BE COORDINATED WITH THE CATALOG NUMBER TO DETERMINE THE EXACT MATERIAL AND ACCESSORIES TO BE ORDERED. THE FIRST MANUFACTURER LISTEDIS THE BASIS FOR DESIGN....

PAF - PAINT AFTER FABRICATION HL - HIGH / LOW LEVEL BALLAST PRS - ELECTRONIC PROGRAM RAPID START BALLAST

FINISH: DIM10 - 0-10V DIMMING BALLAST EM - EMERGENCY BATTERY / BALLAST/DRIVER

(TYPE) BALLAST/DRIVER: (TYPE) BALLAST:

O - OTHER (SEE DESCRIPTION) R - HIGH IMPACT OR ACRYLIC

WL - WALL O - OTHER (SEE DESCRIPTION N - NONE

CL - CEILING SURFACE LED - LIGHT EMITTING DIODE K - KSH12 .125" ACRYLIC

SP - SUSPENDED IN - INCANDESCENT P - POLYCARBONATE

RE - RECESSED FL - FLUORESCENT A - .125 ACRYLIC

(MTG) MOUNTING: (TYPE) LAMP TECHNOLOGY: (L/L) LENS / LOUVER:

LUMINAIRE SCHEDULE

ITEM DESCRIPTION

DIMENSIONS

MTG

ANSIWATT

S

LAMPS BALLAST

L/LAPPROVED

MANUFACTURERL W H DIA. TYPE QTY MODEL VOLTS TYPE

F1 48" INDUSTRIAL STRIP LIGHT,COLD-ROLLED STEEL HOUSING, MEDIUMDIFFUSE LENS, WHITE FINISH, U.L. LISTED.CABLE SUSPENSION TO 8'-0" AFF" OR ASREQUIRED. COORDINATE MOUNTING INEACH ROOM WITH OTHER TRADES ANDEXISTING CONDITIONS AS WELL ASPIPING AND DUCTWORK.

4'-0" 3 3/8" 3 1/4" SP 50 W LED 1 MAX 50 WATTMIN. 4000LUMENS4000K

120 V O METALUX SNLEDLITHONIA Z1LDHE WILLIAMS 75LCOLUMBIA LPT

J

J

JJ

E

E

E

E

E

E

EE

E

E

E

E

E

E

EE

E

H

MM

MM

FS

MS

H

J MM

E

E

E

EE

E

E

E

ES

ES

E

E E

E

E

E

E

J

J

JJ

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

H

MM

MM

FS

MS

H

J MM

R-2POWER RELAY MOUNTEDIN N.E.M.A. 1 ENCLOSUREON WALL ADJACENT TOBOILERS

BLR-1 CONTROL CONTACTS

(SEE FLOOR PLANS FOR BRANCH CIRCUIT DESIGNATION)

120 VAC (EMERGENCY POWER)

NH

5 29/32"

C

ES

ES

BLR-1 CONTROL CONTACTS

BLR-2 CONTROL CONTACTS BLR-2 CONTROL CONTACTS

BLR-3 CONTROL CONTACTS

C

BLR-3 CONTROL CONTACTS

R-1POWER RELAY MOUNTEDIN N.E.M.A. 1 ENCLOSUREON WALL ADJACENT TOBOILERS

TYP. : COORDINATE BOILER CONTROL PANEL120V POWER SUPPLY, WIRING TERMINATIONS,REQUIREMENTS AND CONTACT TYPE WITH M.C.ALL BOILER SHUTDOWN CONTROL WIRING SHALLWIRING SHALL BE #12 AWG IN 1/2" CONDUIT.

O.L.'S

AQUASTAT FURNISHED AND MOUNTED BYMECHANICAL CONTRACTOR, WIRED BY E.C.CONTACT OPENS AT SET TEMPERATURETO STOP PUMP

MANUAL MOTOR STARTERWITH OVERLOAD

120 VOLTCIRCULATION PUMP

120 VOLT CIRCUIT

H N

4 1/4"

E

(SEE FLOOR PLANS FOR BRANCH CIRCUIT DESIGNATION)

MAIL ROOM102

MECHANICAL

EQUIPMENT114

STORAGE115

CORRIDOR117

MAINTENANCE118

COMPACTOR119

BOOSTER PUMP

CONTROL PANEL

(7 1/2HP-QTY. 3)

THERMOSTAT

THERMOSTAT

UNIT HEATER CONTROL

TRANSFORMER

MOTORIZED

DAMPER

BLR-3

BLR-2

BLR-1

FDS-30A

FCS-1AFCS-1AFCS-1A

P-3

P-2

P-1VFD-10

VFD-10

MX-1

120V CO

SENSOR

AV

CO

AV

UNIT HEATER

EXISTING PANEL 'DPE'EXISTING PANEL 'DP2'

EXISTING MAIN

SWITCHBOARD

EXISTING PANEL 'EDP'

EXISTING AUTOMATIC

TRANSFER SWITCH

MX-1

PANEL 'DP-5'

MS-1MS-2

FDS-30A

FDS-30A

P-4P-5

WH-1

WH-2

R-2DP-5-25

R-1DP-5-25

AQUASTAT

CP-2

CP-2

AQUASTAT

EDP-20,22,24

DP-5-19

DP-5-8,10,12

DP-5-13,15,17

DP-5-14,16,18

DP-5-7,9,11

DP-5-2,4,6

DP-5-1,3,5

DP-5-21,23

DP-5-22

DP-5-29

DP-5-29

DP-5-25

BOILER VENTDRAFT CONTROLPANEL

EDP-1,3,5

1

4

5

2

AQUASTAT

6

7

8

8

8

DP-5-19

9

10

R-1DP-5-25

R-1DP-5-25

TC-1DP-5-25

11

MAIL ROOM102

MECHANICAL

EQUIPMENT114

STORAGE115

CORRIDOR117

B-3 S.H.BOILER #3

B-2 S.H.BOILER #2

B-1 S.H.BOILER #1

DHWBOILER

B-3 S.H.PUMP(1HP)

B- 2 S.H.PUMP(1HP)

B-1 S.H.PUMP(1HP)

DHW BOILERCIRC. PUMP(1/3 HP) #9

HEAT EXCH.CIRC. PUMP (.75HP)

P-4 CIRC.DHW PUMP(1/2HP)

HEATING CIRC.PUMP #1(7 1/2HP)

HEATING CIRC.PUMP #1(7 1/2HP)

120V CO

SENSOR

LOOP CIRC.PUMP MANUALSTARTER #11

DHW BOILERPUMP STARTER#2,4,6

HEAT EXCH.PUMP MANUALSTARTER #7

DHW RECIRC.PUMP MANUALSTARTER #15

CP-1 CONROLPANEL #1

CP-2 CONROLPANEL #1

B-1 S.H.BOILER #1STARTER

B-3 S.H.BOILER #3STARTER

B-2 S.H.BOILER #2STARTER

HEATING CIRC.PUMP #1STARTEREDP-1,3,5

HEATING CIRC.PUMP #2STARTEREDP-1,3,5

BOOSTER PUMP

CONTROL PANEL

(7 1/2HP-QTY. 3)

THERMOSTAT

THERMOSTAT

UNIT HEATER CONTROL

TRANSFORMER

MOTORIZED

DAMPER

P-5 DHWRECIRC. PUMP(1/8 HP)

AQUASTAT

LOOP CIRC.PUMP(1/4HP)

UNIT HEATER

AV

CO

AV

3

2

O.L.'S

240V AQUASTAT FURNISHED ANDMOUNTED BY MECHANICALCONTRACTOR, SERIES WIRED BYE.C. CONTACT OPENS AT SETTEMPERATURE TO STOP PUMP

MANUAL MOTORSTARTER WITHOVERLOAD

208 VOLTCIRCULATION PUMP

208 VOLT CIRCUIT

H H

4 1/4"

E

(SEE FLOOR PLANS FOR BRANCH CIRCUIT DESIGNATION)

120 VOLT CIRCUIT

TIME SWITCH, FOR ALTERNATINGPUMPS

H N4 59/64"

TC

TC-1

(SEE FLOOR PLANS FOR BRANCH CIRCUIT DESIGNATION)

P-4 VFD CONTROLTERMINALS

C

C

R-1POWER RELAYMOUNTED INN.E.M.A. 1ENCLOSURE ONWALL ADJACENTTO VFD-10

TYP. : COORDINATE PUMPCONTROL WIRING ANDTERMINATIONS WITH VFDMANUFACTURER. UTILIZE#18 AWG CONDUCTORSFOR ALL CONTROL WIRING.CONTROL POWER ISDERIVED FROM VFDTRANSFORMERS

SAFETYINTERLOCKWIRING TODISABLE P-4IF P-5 ISOPERATING

P-5 VFDCONTROLTERMINALS

START/STOPDIGITAL INPUTTERMINALS

START/STOPDIGITAL INPUTTERMINALS

'READY' RELAYOUTPUTTERMINALS

'RUNNING'RELAYOUTPUTTERMINALS

'READY' RELAYOUTPUTTERMINALS

'RUNNING'RELAYOUTPUTTERMINALS

SAFETYINTERLOCKWIRING TODISABLE P-5IF P-4 ISOPERATING

Tyso

n a

nd

Bill

y A

rch

ite

cts

, P

.C.

4000 M

ors

ay D

rive

Rockfo

rd,

IL

61107

(815)

229-8

222

FA

X: (8

15)

229-8

218

Sheet No:

ww

w.tysonandbill

y.c

om

Drn

.A

pp

d.

Pro

ject N

um

be

rD

ate

REVISION DATE

BO

ND

ING

CO

.C

ON

TR

AC

TO

R

OW

NE

RA

RC

HIT

EC

T

E102

PO

WE

R A

ND

SY

ST

EM

S F

LO

OR

PLA

NS

SP

EN

CE

R T

OW

ER

BO

ILE

RR

EP

LA

CE

ME

NT

111 2

0T

H S

TR

EE

T R

OC

K IS

LA

ND

, IL

12-9

810

3/2

3/1

7D

ON

CR

AJA

RS

CH

REFERENCE SCALE IN INCHES

0 1 2 3

ENGINEERINGCONSULTANTS 309.788.0673 FAX: 309.786.5967

www.kjww.com

623 26TH AVENUEQUAD CITIES, ILLINOIS 61201

PROJECT #

Illinois Design Firm Registration #184-000973

KJWW ENGINEERING RESERVES PROPRIETARY RIGHTS, INCLUDING COPYRIGHTS,TO THIS DRAWING AND THE DATA SHOWN THEREON. SAID DRAWING AND/OR DATAARE THE EXCLUSIVE PROPERTY OF KJWW ENGINEERING AND SHALL NOT BE USEDOR REPRODUCED FOR ANY OTHER PROJECT WITHOUT THE EXPRESS WRITTENAPPROVAL AND PARTICIPATION OF KJWW ENGINEERING. © 2017 KJWW CORP.

The FUTURE.Built SMARTER.

®

00161450.00

NO SCALE3BOILER SHUTDOWN CONTROL

NO SCALE6CIRCULATION PUMP CP-1 CONTROL DIAGRAM

NO R HT

1/4" = 1'-0"1FIRST FLOOR PLAN - POWER

NO R HT

1/4" = 1'-0"2FIRST FLOOR PLAN DEMOLITION - POWER AND SYSTEMS

KEYNOTES:

1. ROUTE 4#2 AND 1#8 GROUND IN 1 1/4" CONDUIT TONEW 100A/3P CIRCUIT BREAKER INSTALLED INEXISTING PANEL 'EDP'. COORDINATE AND SCHEDULEANY DURATION OF POWER OUTAGES AND RACEWAYINSTALLATION ACROSS EXISTING CORRIDOR WITHOWNER TO MINIMIZE DISRUPTION OF OCCUPIEDBUILDING.

2. COORDINATE DOMESTIC WATER BOILER REMOVALAND WATER HEATER INSTALLATIONPHASING/SEQUENCE WITH MECHANICALCONTRACTOR.

3. DISCONNECT AND REMOVE EXISTING PUMPCOMBINATION STARTERS AND RETAIN ASSOCIATEDCONDUIT AND CONDUCTORS DERIVED FROMEXISTING PANEL EDP CIRCUITS 1,2, AND 3, 60A/3PCIRCUIT BREAKER SERVING THE (2) 5 HP PUMPSDESIGNATED TO BE REMOVED. CIRCUIT SHALL BEEXTENDED TO NEW VFD-10 SERVING NEW PUMP P-4.REFER TO 1/E102 FOR LOCATIONS.

4. EXTEND EXISTING 60 AMP CIRCUIT FROM EXISTINGPANEL EDP CIRCUITS 1, 2 AND 3 TO VFD INPUTTERINALS. UTILIZE 3#8 AND 1#8 GROUND IN 3/4"CONDUIT FOR CIRCUIT EXTENSION TO VFD ANDPUMP.

5. ROUTE FEEDER TO NEW 70A/3P CIRCUIT BREAKERINSTALLED IN EXISTING PANEL 'EDP'. COORDINATEAND SCHEDULE ANY DURATION OF POWER OUTAGESAND RACEWAY INSTALLATION ACROSS EXISTINGCORRIDOR WITH OWNER TO MINIMIZE DISRUPTIONOF OCCUPIED BUILDING.

6. REFER TO 4/E102 FOR CIRCULATION PUMP CP-2CONTROL DIAGRAM AND REQUIRMENTS.

7. REFER TO 6/E102 FOR CIRCULATION PUMP CP-2CONTROL DIAGRAM AND REQUIRMENTS.

8. REFER TO BOILER SHUTDOWN CONTROL DETAIL3/E102 FOR REQUIRMENTS.

9. REPLACE (1) 90A/1P CIRCUIT BREAKER, (1) 60A/2P AND(1) 30A/2P 10,000 AIC RATED CIRCUIT BREAKERS WITH65,000 AIC RATED CIRCUIT BREAKERS AND PROVIDE (1)NEW 100A/3P AND (1) 60A/3P 65,000 AIC CIRCUITBREAKER IN EXISTING PANEL 'EDP' WITH ANYREQUIRED MOUNTING KITS. PANEL IS A SIEMENS ITETYPE CDP-7 PANEL WITH A 400A/3P MAIN CIRCUITBREAKER. AT THE CONTRACTOR'S OPTION, THEPANEL INTERIOR AND ASSOCIATED CIRCUITBREAKERS, COVER MAY BE REPLACED WITH NEW65,000 AIC RATED INTERIOR AND CIRCUIT BREAKERS.REFER TO EXISTING PANEL SCHEDULE FORADDITIONAL INFORMATION. COORDINATE ANYOUTAGES WITH OWNER AND MINIMIZE POWEROUTAGE DURATIONS.

10. PROVIDE NEW TYPED PANEL DIRECTORY TO REFLECTLOADS REMOVED. CIRCUIT BREAKERS WITH BRANCHCIRCUIT CONDUCTORS REMOVED SHALL BE LABELEDSPARES. MAJORITY OF BOILER ROOM PUMPS ANDEQUIPMENT REMOVED ARE FED FROM THIS PANEL.

11. REFER TO 5/E102 FOR GENERAL VFD/PUMP CONTROLDIAGRAM AND CONTROL REQUIRMENTS. ROUTE 3#18AWG FROM VFD PID CONTROLS TO M.C. PROVIDEDPRESSURE SENSORS FOR VFD SPEED CONTROL FOREACH PUMP. COORDINATE LOCATION OF PRESSURESENSORS WITH M.C. PROVIDE PIEZO ALARM INSTANDARD EXNCLOSURE FOR EACH VFD ANDCONNECT TO VFD REMOTE ALARM CONTACTS.

E#

SHEET NOTES:

1. REFER TO SHEET E000 FOR GENERAL ELECTRICALNOTES, ELECTRICAL INSTALLATION NOTES,RENOVATION NOTES, PHASING NOTES, ELECTRICALSYMBOLS LIST, DISCONNECT AND STARTERSCHEDULE, VARIABLE FREQUANCY DRIVE SCHEDULEAND PANEL SCHEDULES.

2. COORDINATE NEW EQUIPMENT AND DEVICELOCATIONS WITH NEW AND EXISTING PIPING,DUCTWORK, DEVICES AND EQUIPMENT.

NO SCALE4CIRCULATION PUMP CP-2 CONTROL DIAGRAM

NO SCALE5PUMPCONTROL DETAIL