Upload
mauricio-cabrera-arias
View
75
Download
2
Tags:
Embed Size (px)
Citation preview
Plan_Checker7v3By Dayanti Pratiwi
• BTS_NAME• CI• X: Longitude• Y: Latitude• CELL_TYPE: Macro, Micro, Indoor• CELL_SYST: DCS, GSM• NUM_SECT:
• #of sector 1 for single cell, > 1 for quasi antennas
• AZM1 to AZM4 (azimuth)• -2 for indoor (small square)• -1 for omni antenna (circle)• If single cell just use AZM1 and
others put 0• NCC• BCC• BCCH• TCH1 to TCH7: put 0 if not use• SIZE (optional): in meter
• Was developed under:• Windows XP• MapInfo/MapBasic 7
• Necessary header/column for bts table:
1 © 2005 Nokia Plan_Checker7v2.ppt / 2005-10-25 / DP
Company Confidential
• Necessary header/column for adjacency table (using BTS_NAME format):• SOURCE• TARGET
Plan_Checker7v3By Dayanti Pratiwi
2 © 2005 Nokia Plan_Checker7v2.ppt / 2005-10-25 / DP
Company Confidential
• No need to create specific directory nor specific table name• Flexibility format data txt/xls/mdb for input table • Capable for Frequency Checker; Handover Checker; BSIC Checker; KPI Checker• Additional menu for neighbor audit
• Delete/Create HO, the list of deleted/created relation will be recorded in tabnameAudit.TAB
• Mapping the KPI from different table and create the thematic on the map• Three different style of drawing the btstable for your presentation purposes• Connect the measurement data with related cell using Line Connection
Note: Please exit the tools and run again if you found problem cannot draw the btstable, this is bugs from MapInfo7, I cannot fix it
3 © 2005 Nokia Plan_Checker7v2.ppt / 2005-10-25 / DP
Company Confidential
4 © 2005 Nokia Plan_Checker7v2.ppt / 2005-10-25 / DP
Company Confidential
Arrow style
Clover1 style⇒The DCS and GSM data keep maintain in one table
Clover2 style⇒The DCS and GSM data will be split into two different table
Clover1 style using user defined from column SIZE value
MicroIndoor
Macro GSM
Macro DCS Size = 300
SIZE = 100
Select the coordinate column with XY; and the projection that you useDefault projection is Longitude/Latitude in decimal degree
Follow the instruction on the dialog
Flexible for any data type (txt/xls/mdb)The simplest one is txt format, minimize your mistakes if you forgot to put 0 value when no data
5 © 2005 Nokia Plan_Checker7v2.ppt / 2005-10-25 / DP
Company Confidential
6 © 2005 Nokia Plan_Checker7v2.ppt / 2005-10-25 / DP
Company Confidential
Quasi omni with 4 antennas direction
indoor
Put 0 value if you have no data
7 © 2005 Nokia Plan_Checker7v2.ppt / 2005-10-25 / DP
Company Confidential
Necessary columns are SOURCE & TARGET, the other columns are your own additional data
8 © 2005 Nokia Plan_Checker7v2.ppt / 2005-10-25 / DP
Company Confidential
You need to open the btstable first before continue with the checker menus
9 © 2005 Nokia Plan_Checker7v2.ppt / 2005-10-25 / DP
Company Confidential
Frequency Checker Menus:Open window frequency checker and then select the freq that you want to check
10 © 2005 Nokia Plan_Checker7v2.ppt / 2005-10-25 / DP
Company Confidential
New freq will be checked
Red = co = ch55Blue = co + 1 = ch56Green = co – 1 = ch54
11 © 2005 Nokia Plan_Checker7v2.ppt / 2005-10-25 / DP
Company Confidential
Handover Checker Menus:Open window HO checker; Open HO table; and then select the relation that you want to check
12 © 2005 Nokia Plan_Checker7v2.ppt / 2005-10-25 / DP
Company Confidential
New HO will be checked
Red = selected bts / SOURCEBlue = adjacencies bts / TARGET
13 © 2005 Nokia Plan_Checker7v2.ppt / 2005-10-25 / DP
Company Confidential
Select the bts that you want to add in your neighbor list; and then choose menu Create HO
14 © 2005 Nokia Plan_Checker7v2.ppt / 2005-10-25 / DP
Company Confidential
After Ctr+j you will see that the new neighbors were added
15 © 2005 Nokia Plan_Checker7v2.ppt / 2005-10-25 / DP
Company Confidential
Select the bts that you want to delete in your neighbor list; and then choose menu Delete HO
16 © 2005 Nokia Plan_Checker7v2.ppt / 2005-10-25 / DP
Company Confidential
After Ctr+j you will see that the old neighbors were deleted
17 © 2005 Nokia Plan_Checker7v2.ppt / 2005-10-25 / DP
Company Confidential
Your delete/create list result will be saved in the new tableAudit.TAB in the same directory with your other data
When you delete the adjacency from the HO list there will be blank rows in the adce table, you can Packing the HO Table to clean up the blank rows after you finished the neighbor audit
18 © 2005 Nokia Plan_Checker7v2.ppt / 2005-10-25 / DP
Company Confidential
BSIC Checker Menus:Open window BSIC checker and then select the BSIC or co BCCH_BSIC that you want to check
19 © 2005 Nokia Plan_Checker7v2.ppt / 2005-10-25 / DP
Company Confidential
Check BSIC only, if you want to check co BCCH_BSIC choose menu
20 © 2005 Nokia Plan_Checker7v2.ppt / 2005-10-25 / DP
Company Confidential
KPI Checker Menus:Open window KPI checker; Open KPI table; and then select the column kpi that you want to display
Open KPI tableYou can use any data and no need to create specific table/columns name
Column from KPI table that you want to display will be inserted temporarily into BTS table
If you want to modify the previous threshold and redraw the result
21 © 2005 Nokia Plan_Checker7v2.ppt / 2005-10-25 / DP
Company Confidential
Line Connection Menus:Open window Line Connection; Open measurement table (TAB format); and then draw the line connection between bts vs measurement point using CI as reference
22 © 2005 Nokia Plan_Checker7v2.ppt / 2005-10-25 / DP
Company Confidential
You can use any measurement data (TOM ; TEMS ; etc) as long as you have CI column with integer type in your TAB table
The result will be saved in measnameLine.TAB in the same directory
23 © 2005 Nokia Plan_Checker7v2.ppt / 2005-10-25 / DP
Company Confidential
Note: we are using dummy data for the sample
24 © 2005 Nokia Plan_Checker7v2.ppt / 2005-10-25 / DP
Company Confidential
Have a nice day☺