56
Platelet Adhesion in an Asymmetric Stenosis Flow Model JeffShrum Department of Chemical Engineering McGill University Montreal, Quebec June 2007 A thesis submitted to Mc Gill University in partial fulfillment of the requirements of the degree of Master of Engineering Copyright© Jeff Shrum, 2007

Platelet Adhesion in an Asymmetric Stenosis Flow Model · 1. Introduction Cardiovascular disease is any abnonnal condition characterized by the dysfunction of the heart or blood vessels

  • Upload
    others

  • View
    5

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Platelet Adhesion in an Asymmetric Stenosis Flow Model · 1. Introduction Cardiovascular disease is any abnonnal condition characterized by the dysfunction of the heart or blood vessels

Platelet Adhesion in an Asymmetric Stenosis Flow Model

JeffShrum

Department of Chemical Engineering McGill University Montreal, Quebec

June 2007

A thesis submitted to Mc Gill University in partial fulfillment of the requirements of the degree of Master of Engineering

Copyright© Jeff Shrum, 2007

Page 2: Platelet Adhesion in an Asymmetric Stenosis Flow Model · 1. Introduction Cardiovascular disease is any abnonnal condition characterized by the dysfunction of the heart or blood vessels

1+1 Libraryand Archives Canada

Bibliothèque et Archives Canada

Published Heritage Branch

Direction du Patrimoine de l'édition

395 Wellington Street Ottawa ON K1A ON4 Canada

395, rue Wellington Ottawa ON K1A ON4 Canada

NOTICE: The author has granted a non­exclusive license allowing Library and Archives Canada to reproduce, publish, archive, preserve, conserve, communicate to the public by telecommunication or on the Internet, loan, distribute and sell theses worldwide, for commercial or non­commercial purposes, in microform, paper, electronic and/or any other formats.

The author retains copyright ownership and moral rights in this thesis. Neither the thesis nor substantial extracts from it may be printed or otherwise reproduced without the author's permission.

ln compliance with the Canadian Privacy Act some supporting forms may have been removed from this thesis.

While these forms may be included in the document page count, their removal does not represent any loss of content from the thesis.

• •• Canada

AVIS:

Your file Votre référence ISBN: 978-0-494-38495-4 Our file Notre référence ISBN: 978-0-494-38495-4

L'auteur a accordé une licence non exclusive permettant à la Bibliothèque et Archives Canada de reproduire, publier, archiver, sauvegarder, conserver, transmettre au public par télécommunication ou par l'Internet, prêter, distribuer et vendre des thèses partout dans le monde, à des fins commerciales ou autres, sur support microforme, papier, électronique et/ou autres formats.

L'auteur conserve la propriété du droit d'auteur et des droits moraux qui protège cette thèse. Ni la thèse ni des extraits substantiels de celle-ci ne doivent être imprimés ou autrement reproduits sans son autorisation.

Conformément à la loi canadienne sur la protection de la vie privée, quelques formulaires secondaires ont été enlevés de cette thèse.

Bien que ces formulaires aient inclus dans la pagination, il n'y aura aucun contenu manquant.

Page 3: Platelet Adhesion in an Asymmetric Stenosis Flow Model · 1. Introduction Cardiovascular disease is any abnonnal condition characterized by the dysfunction of the heart or blood vessels

Acknowledgements

The importance of aIl who have helped me in working towards a Master's of engineering degree cannot be understated. l'd like to recognize the following people and apologize for all whom l've missed.

My supervisor at McGill University, Dr. Richard L. Leask, thank you for your guidance, support, understanding of my future desires, as well as your willingness to always help and for being an inspiration to all who work with you.

My research group at McGill; Leonie, Tiffany, Dominique, Andrea, Helen, David, Valerie and J oanna, your knowledge and helpful attitude has been much appreciated.

My co-supervisor at the Montreal Heart Institute, Dr. Yayhe Merhi; thank you for being patient towards a non-traditional medical researcher. Your insight and assistance was very encouraging.

And ta Dr. Merhi's lab group; Dan, Hassiam and especially Jean-Francois Theoret, thank you for putting up with my lack of French language skills. You were always willing ta help answer my questions and, although l'm sure it was, not once did you make me feellike 1 was an extra burden in the labo

1 would also like ta thank the Eugenie Ulmer fund, National Science and Engineering Researeh Couneil and Montreal Heart Institute for funding this research.

11

Page 4: Platelet Adhesion in an Asymmetric Stenosis Flow Model · 1. Introduction Cardiovascular disease is any abnonnal condition characterized by the dysfunction of the heart or blood vessels

Abstract

Platelets have been shown to be a main contributor to thrombus formation in stenotic

arteries leading to acute coronary syndromes. It is thought that increased activation and adhesion

of platelets under variable shear and complex flow conditions contribute to thrombosis. The

objective of this work was to evaluate the relationship between asymmetric stenosis

hemodynamics and platelet adhesion using in-vitro models developed to properly simulate

physiological conditions. In this study, platelet rich plasma was circulated through stenotic and

straight coronary artery models. Adhesion results were obtained by post-perfusion fluorescent

labelling and imaging of adhered platelets. Analysis of platelet area coverage has shown

maximum adhesion occurs in the distal region of the stenosis. Most likely this is due to increased

exposure time of platelets to the wall of the recirculation zone following the stenosis and that

exposure being directly after a period of high shear stress. This resuh gives us a better

understanding of the importance of both shear and flow conditions in coronary artery thrombosis.

iii

Page 5: Platelet Adhesion in an Asymmetric Stenosis Flow Model · 1. Introduction Cardiovascular disease is any abnonnal condition characterized by the dysfunction of the heart or blood vessels

Résumé

li a été démontré que les plaquettes jouent un rôle majeur dans la formation de thrombus

d'artères stenosées suite à leur activation et adhésion accrues par des conditions de cisaillement

variable et d'écoulement complexes. L'objectif de ce travail était d'évaluer le rapport entre l'effort

de cisaillement et l'adhérence des plaquettes en utilisant des modèles in vitro qui simulent

correctement des conditions physiologiques. Dans notre étude, le plasma riche en plaquettes a été

perfusé dans des modèles d'artères cononaires avec et sans sténose. Des résultats d'adhérence ont

été obtenus par microscopie de fluorescence des plaquettes adhérées après la perfusion. L'analyse

des domaines d'adhésion des plaquettes a montré que l'adhérence maximum se produit dans la

région distale de notre modèle avec sténose. C'est probablement c'est dû au plus grand temps

d'exposition des plaquettes à la parois dans la zone de recirculation suivant la sténose et ayant

lieu directement après une zone de cisaillement élevé. Ces résultats contribuent à une meilleure

compréhension de l'importance des conditions de cisaillement et d'écoulement dans la formation

de thrombus.

iv

Page 6: Platelet Adhesion in an Asymmetric Stenosis Flow Model · 1. Introduction Cardiovascular disease is any abnonnal condition characterized by the dysfunction of the heart or blood vessels

Table of Contents 1. Introduction .................................................................................................................................. 1 2. Objectives ..................................................................................................................................... 3 3. Background .................................................................................................................................. 4

3.1. Stenosis .................................................................................................................................. 4 3.2. Platelets ................................................................................................................................. 5 3.3. Platelets under High Shear and Complex Flow Conditions .................................................. 6 3.4. Atherothrombosis and Embolization ..................................................................................... 7 3.5. Stenosis Hemodynamics ....................................................................................................... 8 3.6. Other Models ....................................................................................................................... 10

3.6.1. Annular Perfusion Chambers ....................................................................................... 11 3.6.2. Cone and Plate Viscometer .......................................................................................... 11 3.6.3. Parallel Plate Perfusion Chambers ............................................................................... 12 3.6.4. Parallel Plate Perfusion Chambers with Stenosis ......................................................... 13 3.6.5. Column and Tubular Perfusion Chambers ................................................................... 14

4. Material and Methods ................................................................................................................. 16 4.1. Model Preparation ............................................................................................................... 16 4.2. Model Preparation and Coating ........................................................................................... 18 4.3. Coating Verification ............................................................................................................ 18 4.4. Perfusion Experiments .................................................................. , ..................................... 19

4.4.1. Platelet Rich Plasma Preparation ................................................................................. 19 4.4.2. PRP Viscosity and Reynolds Values ............................................................................ 19 4.4.3. Perfusions .......................................................................... , .......................................... 20

4.5. Fluorescent Microscopy and Area Percent Analysis ........................................................... 21 4.6. Radiolabelling and Gamma Counter Analysis ...................... ; ............................................. 23

4.6.1. Radiolabelling Platelets ................................................................................................ 23 4.6.2. Gamma Counter ........................................................................................................... 23 4.6.3. Blank Radioactive Solution Test. ................................................................................. 24

4.7. Statistical Analysis .............................................................................................................. 25 5. Results ........................................................................................................................................ 26

5.1. Collagen Coating Verification ............................................................................................ 26 5.2. Platelet Rich Plasma Properties ........................................................................................... 28 5.3. Gamma Counter .................................................................................................................. 28

5.3.1. Blank Solution Results ................................................................................................. 30 5.4. Fluorescent Microscopy Analysis ....................................................................................... 31

5.4.1. Sample Pictures ............................................................................................................ 31 5.4.2. Area Percent Coverage ................................................................................................. 31 5.4.3. Regional Comparison ................................................................................................... 32

6. Discussion ................................................................................................................................ 34 6.1. Coating Verification ............................................................................................................ 34 6.2. Fluorescence Microscopy Imaging ..................................................................................... 35 6.3. Model Comparison .............................................................................................................. 35

7. Conclusions ................................................................................................................................ 40 8. Limitations and Future Work ..................................................................................................... 41

8 .1. Radioactive Platelet Adhesion ............................................................................................ 41 8.2. Fluorescence Microscopy Imaging - Protocol Development. ............................................ .41

v

Page 7: Platelet Adhesion in an Asymmetric Stenosis Flow Model · 1. Introduction Cardiovascular disease is any abnonnal condition characterized by the dysfunction of the heart or blood vessels

8.3. In-vitro Model ..................................................................................................................... 42 8.3.1. Geometry ...................................................................................................................... 42 8.3.2. Model Coating .............................................................................................................. 43 8.3.3. Model Compliance ....................................................................................................... 43

8.4. Experimental Conditions ..................................................................................................... 44 8.4.1. Perfusate ....................................................................................................................... 44 8.4.2. Circulation .................................................................................................................... 44

8.5. Experimental Justification ................................................................................................... 45 9. References .................................................................................................................................. 46

VI

Page 8: Platelet Adhesion in an Asymmetric Stenosis Flow Model · 1. Introduction Cardiovascular disease is any abnonnal condition characterized by the dysfunction of the heart or blood vessels

1. Introduction

Cardiovascular disease is any abnonnal condition characterized by the dysfunction of the

heart or blood vessels. This definition includes coronary heart disease, valve disease, heart

electrical system problems and strokes. It is the number one killer in Canada and accounted for

74,626 deaths in 2002, amassing to an economic cost of $18 billionlyear based on 1998 data

(Canadian Heart and Stroke Foundation). Research in this field has been ongoing for the past

century but only recently has it moved away from mechanical based solutions to solutions based

on the biochemistry and biology of the disease. Due to the complexity of the disease process,

progress has been slow but is beginning to show hope for developing new treatment options.

Platelets have been intensely researched due to their involvement in cardiovascular disease

development, particularly in heart attacks and strokes.

Under nonnal physiological conditions platelets circulate in blood and respond to vessel

injury by changing shape, secreting their granule contents and aggregating (Italiano et al., 1999).

Ultimate1y the injury is repaired and platelet activation returns to nonnal levels. In diseased

arteries, platelets can react in a very similar matter and fonn a thrombus at or following a

restriction in the vessel due to atherosclerotic plaque (stenosis) (Ruggeri et al., 2000). This

thrombus can then either fonn a blockage in that area of the vessel or travel downstream and clog

a smaller diameter vessel, ultimately leading to a heart attack or stroke (Andrews et al,. 1997).

Reasons for the activation of platelets in these situations is up for debate but studies have shown

that both high and low wall shear stress (WSS) can contribute to increased platelet activation and

transport in these regions (Andrews et al,. 1997; Maxwell et al., 2006; Weeterings et al., 2006).

To date, in-vitro models have provided important findings on the relationship

between shear stress and platelet function but are lacking in their ability to properly simulate

physiological conditions. Perhaps most importantly, geometrical and flow considerations have

1

Page 9: Platelet Adhesion in an Asymmetric Stenosis Flow Model · 1. Introduction Cardiovascular disease is any abnonnal condition characterized by the dysfunction of the heart or blood vessels

largely been ignored. This study attempts to bridge that gap by using 3D tubular models to

analyze platelet adhesion under high shear and complex flow conditions.

2

Page 10: Platelet Adhesion in an Asymmetric Stenosis Flow Model · 1. Introduction Cardiovascular disease is any abnonnal condition characterized by the dysfunction of the heart or blood vessels

2. Objectives

The objective of this work was to investigate the link between platelets and shear stress

using in-vitro 3D, tubular stenotic and straight coronary artery models. The following questions

were to be answered:

Do the hemodynamics created by an asymmetric stenosis increase platelet adhesion?

Is platelet adhesion focal in a stenotic geometry?

3

Page 11: Platelet Adhesion in an Asymmetric Stenosis Flow Model · 1. Introduction Cardiovascular disease is any abnonnal condition characterized by the dysfunction of the heart or blood vessels

3. Background

3.1. Stenosis

In a tubular organ or structure, a stenosis can be defined as any abnormal narrowing of

that geometry. Of specific interest to this study, stenotic arteries are caused by the narrowing of

blood vessels (atherosclerosis) and can be found throughout the body. Figure 3.1 shows an

illustration of an atherosclerotic plaque in a coronary artery.

Figure 3.1. Healthy and Atherosclerotic Arteries (Adapted from the University of Surrey, 2007)

These plaques are thought to be initiated by the dysfunction of endothelial cells lining the artery,

followed by the build up of cholesterol and lipids and hyperplasia of the vessel walls, eventually

leading to the formation of an atherosclerotic lesion. The largest proportion of this les ion can

consist of lipids and cholesterol, with the remainder being compounds such as calcium and fibrin.

Fibrin acts as a stabilizing material both within the plaque and as the main component of a

fibrous cap formed on mature les ions (Egbrink et al., 2005).

Due to the dramatic change in vessel diameter and structure of stenotic arteries, profound

effects can be seen in local blood flow behavior. For instance, shear rates vary dramatically

proximal to distal of the plaque with wall shear rates as high as 10000 S-I, 100 times greater than

in healthy arteries, located before and/or at the stenosis apex (Ruggeri et al., 2006). Additionally,

blood flow patterns change, resulting in complex laminar flow that causes the formation of eddies

4

Page 12: Platelet Adhesion in an Asymmetric Stenosis Flow Model · 1. Introduction Cardiovascular disease is any abnonnal condition characterized by the dysfunction of the heart or blood vessels

and low wall shear stress in the distal region. This results in platelets undergoing periods of high

shear stress in the proximal and peak regions followed by recirculation and low shear stress distal

to the stenosis. Consequently, platelets interact differently with the vessel wall and other blood

components when exposed to conditions found in diseased arteries compared to healthy vessel

interactions.

3.2. Platelets

For homeostasis and thrombosis processes to occur the following platelet interactions are

required. First, adhesion of glycoprotein' s on the surface of platelets to extracellular matrix

(ECM) proteins such as von Willebrand factor (vWf), collagen, fibronectin, vitronectin and

laminin. This is followed by aggregation with each other to make a platelet plug and heterologous

adhesions with other cells (Kieffer and Phillips, 1990). Specific glycoproteins on the platelet

surface regulate aIl of these processes (Andrews et al., 1997; Kieffer and Phillips, 1990). The

initial step involves complex interactions between receptors on the platelet surface and adhesive

substrates (Kulkami et al., 2000). Under low shear conditions the main association is

glycoprotein GP la/lIa with collagen in the ECM but under high shear the dominate adhesion

pathway becomes the binding of GP !bu with vWf (Kulkami et al., 2000). Aggregation occurs

when free flowing platelets expressing GP !bu bind with vWf on the surface of activated platelets

(Kulkarni et al., 2000). Finally the aggregate is stabilized with the irreversible binding of integrin

UrIb P3 to vWf or fibrinogen (Kulkami et al., 2000).

Vessel wall components and other compounds within the body regulate platelet function.

Upon initial damage to the cellular wall, exposed subendothelium contains a number of platelet

activating factors such as thrombin, ADP, thromboxane, platelet activating factor and scrotonin

(Davis et al., 2003). Once activated, platelets release proinflammitory compounds including

5

Page 13: Platelet Adhesion in an Asymmetric Stenosis Flow Model · 1. Introduction Cardiovascular disease is any abnonnal condition characterized by the dysfunction of the heart or blood vessels

cellular adhesion molecules, cytokines, chemokines and other growth factors, as well as

expressing ligands such as P-selectin (Davis et al., 2003). These factors work to recruit additional

platelets to the site of vascular injury, promoting further adhesion, activation and aggregation.

3.3. Platelets under High Shear and Complex Flow Conditions

High WSS alters the way in which platelets interact with ECM proteins and how they are

transported to the vessel wall. As mentioned above, the adhesion pathway mainly occurs through

the binding of GP Ibu with vWf. Thrombus formation can occur without vessel injury due to vWf

expression by endothelial ceUs and in circulation plasma. Concurrently, high WSS results in a

decrease in endothelial production of antithrombic compounds such as nitric oxide and

prostacyclin. This combined with the np-regulation of prothrombic and proinflammitory factors

discussed above further promotes thr·;)mbus formation (Huo and Ley, 2004). Platelets have also

been shown to concentrate near the artery wall under high shear conditions (Wootton et al.,

2001). This is due to the shear thinning behavior of blood that results from red blood cells

migrating in the middle of the artery, pushing platelets towards the wall. Consequently, higher

numbers of platelets are exposed to activating factors of the vessel wall when compared to low

shear conditions.

High shear rates, turbulence, and areas of stagnation or recirculation are sorne fluid

mechanical factors that are believed to effect both activation and aggregation (Einav and

Bluestein, 2004). It is the combination of these fluid mechanical factors and the biochemical

reactions associated that likely cause increased thrombus formation in these regions. The

resulting complicated flow patterns effeet platelet activation, thrombus formation and overall

physiological blood circulation (Mates et al., 1978; Wootton et al., 2001; Zhang et al., 2002).

6

Page 14: Platelet Adhesion in an Asymmetric Stenosis Flow Model · 1. Introduction Cardiovascular disease is any abnonnal condition characterized by the dysfunction of the heart or blood vessels

3.4. Atherothrombosis and Embolization

Within stenotic arteries, clinical events are most often caused by atherothrombosis, the

generation of thrombus by an atherosclerotic plaque. This most frequently happens because the

atherosclerotic plaque is unstable and damage to the fibrous cap occurs. Damage to this cap can

initiate an anti-inflammatory response very similar to platelet response to a damaged vessel.

Platelets activate and adhere to the site, initiating the process and leading to aggregation and

thrombus formation. This thrombus can block flow in the already flow restricted artery, causing a

possible heart attack or stroke (Egbrink et al., 2005). An illustration of atherothrombosis is

shown in figure 3.2.

Figure 3.2. Atherothrombosis (NIH National Heart Lung and Blood Institute, 2007)

Up to 1/3 of atherothrombosis in coronary plaques occUr without rupture (Virmani et al.,

2006). The effects of which are often seen downstream due to embolization. Aggregate formation

that occurs at the stenosis or in the distal region will embolize and travel downstream to block

flow in a smaller diameter artery or different stenosis (Egbrink et al., 2005). This process is

linked directly to complex flow conditions and both low and high shear rates found in these

7

Page 15: Platelet Adhesion in an Asymmetric Stenosis Flow Model · 1. Introduction Cardiovascular disease is any abnonnal condition characterized by the dysfunction of the heart or blood vessels

regions. It is theorized that platelets exhibit inereased adhesion and aggregation at these junctures

due to increased activation from high shear rates and the complex flow conditions that provide

greater exposure to adhesive substrates in the vessel wall (Einav and Bluestein, 2004). Ultimately

embolization leads to the same undesired result as plaque rupture.

3.5. Stenosis Hemodynamics

Shear stress (r) is defined as the tangential force per unit area exerted in the direction of

flow (de Groot and Sixma, 2002). And is related linearly to shear rate (duldr) by the following

relationship with viscosity (Il):

du -r(r)=p*­

dr (3.1)

Within a cylindrical vessel and for a Newtonian fluid undergoing ID, steady flow, the following

equation with volumetrie flow rate (Q) and radius (r) can be applied to obtain wall shear stress.

(3.2)

Although blood is not considered a Newtonian fluid, the above provides a good estimate

at high shear rates. Within the body, shear rate ranges from values of 0 S-l (no flow) to greater

than 10000 S-l in capillaries and stenotic arteries, of which anything greater than 1300 S-l can be

considered high shear (de Groot and Sixma, 2002).

Coronary stenosis of significant size most often occur on only one side of the artery wall.

This asymmetric geometry creates a unique hemodynamic pattern with large spatial gradients in

fluid and wall shear stress. In this work, two idealized coronary artery flow geometries were

investigated. A straight tubular model which pro duces simple 1 dimensional laminar flow

(equation 3.2) and a 75% asymmetric model (figure 3.3).

8

Page 16: Platelet Adhesion in an Asymmetric Stenosis Flow Model · 1. Introduction Cardiovascular disease is any abnonnal condition characterized by the dysfunction of the heart or blood vessels

Inlet

Peak r---i

Proximal 1 Outlet

Figure 3.3. Straight and Stenosis Coronary Artery Model

Flow patterns and shear rates in the 75%, by area occlusion, stenosis model are difficult to

characterize but have been investigated in previous studies. The inlet of this model will

experience fully developed laminar flow and an average WSS, just like the straight model. More

complex flow and variable shear patterns begin to occur in the proximal region.

A study done by Kaazempur-Mofrad et al. (2005) that looked at mass transport and fluid

flow in a 56 % area reduction asymmetric stenosis nicely illustrates flow patterns produced in our

model. In the proximal region, flow accelerates into the converging part of the stenosis and the

non-symmetric geometry creates secondary flow directed to the healthy wall (opposite the

stenosis). Both flows combine to produce separation immediately before the apex of the stenosis.

Distal to the stenosis, a complex retrograde flow zone exists. The high momentum fluid core

coming out of the stenosis throat will interact with the complex retro grade flow zone, creating

flow recirculation along the diseased wall. Figure 3.4 illustrates the flow features and figure 3.5

shows the wall shear stress created.

9

Page 17: Platelet Adhesion in an Asymmetric Stenosis Flow Model · 1. Introduction Cardiovascular disease is any abnonnal condition characterized by the dysfunction of the heart or blood vessels

ID Flow ..

Recirculation

Figure 3.4. Idealized Flow Features in an Asymmetric Stenosis

,; Diseased

Through Focus

Ob-~~~~O~~~~~~5~~~~~~10~~~~~~1~5~

-1 zlD

Figure 3.5. Asymmetric Stenosis Normalized Wall Shear Stress (WSS) (z - distance from the stenosis peak, D - normal vessel diameier) [Adapted from Kaazempur-Mofrad et al. (2005)]

For our application, all of these findings can be simplified and summarized as shown in table 3.1.

Region [nlet

Proximal Peak

Distal (Healthy Side) Distal (Diseased Side) Outlet (Healthy Side) Outlet (Diseased Side)

Flow Pattern(s) Fully Developed Laminar

Acce1erating Acceleration and Expansion

Fluid Core Expansion Retrograde, Recirculation

Fluid Core Expansion Forward Re-establishing Laminar ID

Relative Wall Shear Stress Average

High High

High to Average High to Very Low

Average Low to Average

Table 3.1. Estimated Relative Shear Stress and Flow Patterns - Asymmetric Stenosis

3.6. Other Models

Researchers have discovered the importance of the effect of shear stress and complex

flow conditions in stenotic arteries on platelet activation and thrombus formation and,

10

Page 18: Platelet Adhesion in an Asymmetric Stenosis Flow Model · 1. Introduction Cardiovascular disease is any abnonnal condition characterized by the dysfunction of the heart or blood vessels

consequently, many other in-vitro studies have been published about this relationship. Sorne of

the most relevant are summarized with their results and limitations below.

3.6.1. Annular Perfusion Chambers

Annular perfusion chambers developed by Baumgartner were the first successful in-vitro

device to be used for the se types of studies (Sakariassen et al., 2001). Briefly this model

consisted of a central cylindrical rod that was covered by exverted rabbit or human

subendothelium. This rod was fit inside a larger diameter tube and blood flow was directed into

the annulus. The shear rate was adjusted by either changing the flow rate or width of the annulus.

Using morphological criteria, the adhesive and cohesive function could be differentiated and

quantified by means of morphometric procedures. This method was the first to highlight the

importance of vWF, GP !bu and integrin UlIb~3 at high shear rates (Turitto and Baumgartner,

1974). Disadva!ltages of this model resulted from the difficulty of preparing and exverting the

subendothelium, expense of analyzing the results and the invalid annular flow geometry.

Consequently, studies using this type of model are hardly done anymore but have been employed

as recently as 2004 to test the affect of anti-inflammatory drugs on platelet/subendothelium

interaction (Hernandez et al., 2004).

3.6.2. Cone and Plate Viscometer

A cone and plate viscometer works by subjecting blood or other fluids to high shear rates

by sandwiching the fluid between a plate and cone, and rotating the cone to get the desired shear

rate. The general setup is shown in figure 3.6.

e Cone, xadius r

~~=Îiiiiiil~=E-Plate

Figure 3.6. Cone and Plate Viscometer

11

Page 19: Platelet Adhesion in an Asymmetric Stenosis Flow Model · 1. Introduction Cardiovascular disease is any abnonnal condition characterized by the dysfunction of the heart or blood vessels

Torque is applied to rotate the cone at a constant angular velocity relative to the plate. Keeping

constant angular velocity achieves an equivalent shear rate for all fluid segments due to

increasing distance between the co ne and plate as a functÏon of distance from the axis. Many

studies have used this basic set-up and resulted in sorne significant findings. For instance, it has

been repetitively shown that platelet activation increases under high shear conditions through the

increased activity of GP Ibu - vWf binding (Goto et al., 1998; Leytin et al., 2004; Shankaran et

al., 2003). Unfortunately, the exposure time of platelets to high shear in most of these

experiments is significantly longer that those experienced in-vivo. Accordingly, others have

tested for platelet activation under exposure times of 1-2 seconds and found that high shear stress

alone is not sufficient to activate and aggregate the platelets (Zhang et al., 2002; Zhang et al.,

2003). Thus, showing the other factors must be accounted for in these types of studies. Exposure

time is not the only factor that is simulated incorrectly by cone and plate experiments. For

instance,the surface of which platelets are in contact with is generally stainless steel not the

complex vessel wall components platelets are physiologically exposed to. Consequently,

experimental apparatuses have been designed to better simulate in-vivo conditions.

3.6.3. ParaUel Plate Perfusion Chambers

The parallel plate flow chamber is likely the most commonly used experimental apparatus

for shear stress/cellular component interactions due to the ease in which the resuIts can be

analyzed and ability to investigate vessel wall component interactions under weIl controlled and

reproducible conditions. The general experimental setup of a parallel plate flow chamber in

shown in figure 3.7.

12

Page 20: Platelet Adhesion in an Asymmetric Stenosis Flow Model · 1. Introduction Cardiovascular disease is any abnonnal condition characterized by the dysfunction of the heart or blood vessels

:::::::::;::::~~---------------G~sSliœ ______________ :~~--------------Md~Smms

..... ---------Adhend ~:eU$

l :Botlom. S:ide '-----

(VeJU"ed Sub~trate)

Figure 3.7. Parallel Plate Perfusion Chamber (Arizona State University, 1999)

For platelet experiments, a thombogenic surface is seeded on the bottom slide and exposed to

flowing blood or plasma at varying shear rates (de Groot and Sixma, 2002). The advantage of the

system results from the ease in which interactions can be analyzed immediately after the

experiment due to having a flat and accessible surface to work with (Sakariassen et al., 1988).

Many important findings on the relationship between platelets and components of the ECM have

resulted. For instance, it has been shown that immobilized thrombin also plays an important role

in activating platelets via GP Iba (Weeterings et al., 2006). Furthermore, after activation, the

requirement of integrin allb~3 and fibrinogen or vWf for forming stable aggregates has been

discovered (Goto et al., 1998; Kulkarni et al., 2000; Ruggeri et al., 2000). Although significant

results, such as those presented here, have come out of these studies, the geometry used is not

comparable to in-vivo and further research should focus on using more accurate model geometry.

3.6.4. Parallel Plate Perfusion Chambers with Stenosis

Barstad et al. (1994, 1996) came to a similar conclusion about the inappropriate geometry

of parallel plate perfusion chambers and developed a model containing a cosine shaped stenosis.

Basically this was the same setup as the parallel plate perfusion chamber previously described

13

Page 21: Platelet Adhesion in an Asymmetric Stenosis Flow Model · 1. Introduction Cardiovascular disease is any abnonnal condition characterized by the dysfunction of the heart or blood vessels

except a steno sis was added with area reductions of 60% to 90%. This resulted in shear rates

ranging from 2600 to 32000 S-l, respectively. At these shear rates, it was found that increased

thrombus formation occurred at the apex of the stenosis when compared to flat models. This

result is significant in that it shows the importance of geometry on platelet adhesion, activation

and geometry, but the model still incorporates the erroneous flat plate profile as weIl as

unrealistically large shear rates in sorne of the studies.

3.6.5. Column and Tubular Perfusion Chambers

Likely the first of this type to be developed was the glass bead perfusion column. InitiaUy

used as a simple way to test platelet adherence and retenti on, the model consisted of simple tubes

of approximately 3 mm ID packed with smaIl glass beads (Rossi and Green, 1972; Salzman et

al., 1963). More recently, copolymer plastic sphere beads coated with type I coIlagen were

developed to replace glass beads (Kaneko et al., 2005). This removed the glass effect and

resulted in a model that is doser to in-vivo conditions. Results from studies with these models

have shown the importance of shear on the GP lb - vWF binding pathway as weIl as the adhesion

abilities of specific ECM proteins (Kaneko et al., 2005; Polanowska-Grabowska et al., 1999).

Badimon et al., (1986) were the first to develop tubular models to test platelet adhesion

and aggregation on exposed components of the vessel wall. In general, their studies showed that

platelet deposition increased with both increasing shear stress and perfusion time. Another model

recently used has been perfusions through microcapillaries coated with vWF (Maxwell et al.,

2006). Researchers have been able to foIlow up on the biomechanics and biochemical reactions

involving vWf under shear conditions. The geometry of these studies is doser to in-vivo

conditions, but still missing the complex flow pattern observed in stenotic arteries.

14

Page 22: Platelet Adhesion in an Asymmetric Stenosis Flow Model · 1. Introduction Cardiovascular disease is any abnonnal condition characterized by the dysfunction of the heart or blood vessels

Consequently, stenotic models have been developed with tubular geometries (Bluestein et

al., 1997; Einav and Bluestein, 2004; Jesty et al., 2003; Schoephoerster et al., 1993). Jesty et al.

(2003) used a 2.8 mm diameter tube connected with a 0.97 mm tube, then reconnected to the

larger diameter tube to simulate a stenosis. The length of the smaller 'stenotic' tube was varied

from 0 - 1.5 meters and, after the perfusion, platelet rich plasma was tested for platelet activation.

They determined that both high shear and the duration of that shear was responsible for increased

platelet activation. Problems with this method come from the unrealistically long stenotic region

and, subsequently, duration of the shear pulse. Schoephoerster et al. (1993) looked at platelet

adhesion in an axisymmetric stenosis (84% by are a) Lexan model and other geometries via

perfusion with platelet rich plasma containing I11In labelled platelets. They found platelet

adhesion to be maximum in the distal region and minimum at the peak of the stenosis. More

generally, their model showed increased platelet adhesion in periods of flow recirculation and

reattachment and minimum adhesion in locations of high shear and separation. Although, this

study is significant since it uses a tubular stenosis model, it still does not incorporate any vessel

wall components and other steno sis geometries should be considered since symmetric stenoses

represent only l/8th of cases (Brown et al., 1984).

To overcome the limitations of the previously mentioned models, we have developed a

transparent, non-toxic asymmetric coronary flow model. In this thesis, the model was used to

evaluate the link between platelets and shear stress interactions and determine if asymmetric

steno tic arteries increase platelet adhesion.

15

Page 23: Platelet Adhesion in an Asymmetric Stenosis Flow Model · 1. Introduction Cardiovascular disease is any abnonnal condition characterized by the dysfunction of the heart or blood vessels

4. Material and Methods

4.1. Model Preparation

Bigaussian, 50% by area occlusion, asymmetric stenosis and straight 3 mm diameter

coronary artery models were prepared using a procedure developed in our labo Due to fabrication

limitations and the need to model a significant plaque, the stenotic models were also pinched to

increase the size of the occlusion (-75%). To construct a casting block of the model lumen, a

computer assisted design (CAD) model ofthe asymmetric stenosis lumen was created, figure 4.1.

Figure 4.1. Asymmetric Stenosis CAD Model

From this mode!, acrylic casting blocks were computer numerical control (CNC) machined into

molds that were used to cast the simulated lumen arteries (figure 4.2 (a) and (b)). To ensure

uniformity and accuracy of the lumen casts, the molds were cooled to -20°C in a laboratory

freezer. Once cooled, ice crystals were removed from the interior of the mold and low melting

alloy (Cerrolow-117, BeUefont, PA, USA) heated to 55°C was poured inside. The mold was then

placed back into the freezer and, after cooling; the simulated lumen was removed and poli shed

using micro-grit (600P) sandpaper and a Dremel™ tool (300-1150 Series, Racine, WI, USA).

Figure 4.2. (a) Acrylic Lumen Mold - Side View (b) Acrylic Lumen Mold - Front View (c) Final Alloy Casts

16

Page 24: Platelet Adhesion in an Asymmetric Stenosis Flow Model · 1. Introduction Cardiovascular disease is any abnonnal condition characterized by the dysfunction of the heart or blood vessels

The alloy casts were then placed in a container and Sylgard 184® (Dow Corning, PA, USA)

polymerized around the cast.

Figure 4.3. Acrylic Wall Mold Containing Low MeIting Alloy Lumen Cast

Sylgard 184® was prepared in volumetrie flasks using a 10:1 ratio of elastomer base to curing

agent, then mixed and degassed in a vacuum chamber (Alcatel, QC, Canada) until no bubbles

were visible. The mixture was then slowly poured into the mold shown in figure 4.3 and allowed

to sît at room temperature until any bubbles formed in the pouring process rose to the top. Plastic

connectors (5121K15 (3/16"), McMaster Carr, USA) are then fitted onto the top of the lumen

alloy mold and the models are placed in an oven (Fisher Scientific, USA) at 37°C and left

overnight for curing. Afterwards, the models were carefully uncast and any excess Sylgard 184®

was trimmed using a razorblade.

Figure 4.4. Asymmetric and Straight Sylgard 184® Models

17

Page 25: Platelet Adhesion in an Asymmetric Stenosis Flow Model · 1. Introduction Cardiovascular disease is any abnonnal condition characterized by the dysfunction of the heart or blood vessels

4.2. Model Preparation and Coating

Before use in the perfusion experiments, each model was sterilized in boiling water for 30

minutes and hydrophilized by injecting 70 % sulphuric acid (A-300-500, Fisher Scientific, USA)

into the interior and letting sit for 45 minutes. This procedure ensures wetability for collagen

attachment and reduces the risk of contamination. To coat the interior with collagen, 0.1 %

collagen type 1 from calf skin (C8919, Sigma-Aldrich Inc, MO, USA) and sterile water was

combined on a 1/10 basis. One ml of the resulting solution was then pipetted into the model

interior and left to adhere to the model interior wall for three hours, rotating the model every 30

minutes to obtain a uniform coating. After this time period, the model was placed in the oyen at

37 oC to evaporate the coating solution. This process takes about 48 hours, after which the final

coated models are stored at 3 oC until use.

4.3. Coating Verification

The attachment of collagen to the surface was verified with attenuated total reflectance

Fourier transform infrared spectroscopy (ATR-FTIR) (Brucker 27, Bruker, Germany) analysis

with a mid-IR interferometer and 17 bounces. This technique works by utilizing the fact that

bonds vibrate at characteristic frequencies when exposed to infrared light. The samples

transmittance and reflectance of infrared rays at different frequencies are transformed into an

adsorption plot during the procedure. This plot can then be analyzed to determine what bonds the

specimen contains and its ensuing identification elicited. For our experiment we obtained the

spectrum of non-coated Sylgard 184® and compared that to Sylgard 184® coated with collagen

according to the previously described coating procedure. And, for further comparison purposes,

we analyzed Sylgard 184®, coated with de-ionized water using our collagen coating procedure.

18

Page 26: Platelet Adhesion in an Asymmetric Stenosis Flow Model · 1. Introduction Cardiovascular disease is any abnonnal condition characterized by the dysfunction of the heart or blood vessels

4.4. Perfusion Experiments

4.4.1. Platelet Rich Plasma Preparation

Platelet rich plasma (PRP) was chosen as the perfusion fluid and prepared as follows.

First, blood was obtained from healthy pigs that had not been on any platelet altering medication

over the previous 10 days. 100 ml was drawn from the anti-cubetal vein or directly from the heart

into two 60 cc syringes each containing 10 cc of citrate dextrose (Baxter Healthcare Corp., IL,

USA). PRP was prepared by initially centrifuging anti-coagulated whole blood at 1800 rpm for

15 minutes. The supernatant was then transferred to clean 50 ml centrifuge tubes (2) and the

pellet, containing mostly red blood cells, was discarded. Centrifugation of this supernatant for 10

minutes at 2700 rpm created a separate platelet poor plasma (PPP) solution and pellet containing

mostly platelets. The supernatant, PPP, was then transferred to new tubes (2) and centrifuged for

20 minutes at 3500 rpm to remove any remaining cellular components. Both pellets are re­

suspended in 10 ml of citrate buffer solution (pH = 7.4) and combined to< make one platelet,

citrate buffer solution. This solution was then centrifuged at 2200 rpm for 10 minutes, the

supernatant aspirated and pellet re-suspended in PPP to make PRP. An automated cell counter

(T890, Beckman Coulter Inc., CA, USA) was used to adjust the PRP to a final platelet

concentration of approximately 250 x 106/ml (no less than 200 x 106/ml or greater than 300 x

106/ml). Figure 4.5 shows a step by step schematic of this isolation procedure.

4.4.2. PRP Viscosity and Reynolds Values

Windberger et al. (2003) found the viscosity of pig plasma to be 1.58 mPa*s using an

oscillating capillary rheometer and densitometer. We took this to be equivalent to PRP viscosity

since platelets take up negligible volume in the solution. From this value the Reynolds number

was calculated to be 252 in the normal flow region and approximately 505 at the stenosis apex.

19

Page 27: Platelet Adhesion in an Asymmetric Stenosis Flow Model · 1. Introduction Cardiovascular disease is any abnonnal condition characterized by the dysfunction of the heart or blood vessels

Whole Blood (lOOml) + Citrate Dextrose (lOml)

l ~e AC Whole Blood (30 ml) AC Whole Blood (30 ml) AC Whole mood (30 ml) AC Whole Blood (30 ml)

C,ntrifug, @ 1800 rpm

l.5Minutgs

'Blood'+RBC's (3Oml) 'Blood'+RBC's (3Oml) 'Blood'+RBC's (30ml) 'Blood'+RBC's (3Oml)

'Blood' (-40ml)

ppp + Platelets (-40ml)

ppp (-75ml)

Discard BDC'. (pelkt)

Comlli_ '8ÙJod' (supemataniJ

'Blood' (-40ml)

Centrifug, @ 2700 rpm

10Minut,s

ppp + Platelets (-40ml)

Combine ppp (supmzatant)

Mx Plate/els (pell,t) wl Citrate (20 ml)

Platelets + Citrate (-lOml)

! Centrifuge @ 3.500 rpm 1 Centrifuge @ 2200 rpm

20 Mmutes

Plasma + Cellular Components (-75ml)

Discard C"llular ~ Components (pellet) ~

... 10 Minutes

Platelets + Citrate (-lOml)

~ASPirate Citrat, (supernatant)

PRP @ 250xl0"6 (15ml) PRP @ 250xlO"6 (15ml) PRP @ 250xl0"6 (lSml) PRP @ 250xlO"6 (15ml)

Figure 4.5. Step by Step Isolation Process

4.4.3. Perfusions

Perfusions with PRP were done through four models placed in parallel. Two stenosis

models, one collagen coated, one non-coated and two straight models, one collagen coated, one

non-coated. Prior to perfusion, each model was dip rinsed in physiological saline, attached to 3

mm diameter tubing and immersed in a thermostatically controlled Lauda water bath (Brinkmann

Instruments, ON, Canada) at 37°C. PRP, 15 ml per model, was heated in the water bath to 37°C

and then circulated through for a 15 minute time period at a flow rate of 53 ml/min by a

peristaltic pump (model 7524-40, Masterflex, Cole-Parmer Instruments Co., QC, Canada). These

20

Page 28: Platelet Adhesion in an Asymmetric Stenosis Flow Model · 1. Introduction Cardiovascular disease is any abnonnal condition characterized by the dysfunction of the heart or blood vessels

flow conditions correspond to a shear rate of 333 S·1 at the inlet (3 mm diameter region) and

increases to -5100 S·1 at the peak of the 75% stenosis. Numerical simulations still need to be

completed to define aIl regions of the stenotic model. Following perfusion, the models are dip

rinsed in phosphate buffer solution (PBS) (BP399-1, Fisher Scientific, USA), and immersed in

tubes containing tissue fix (TissueFixMD, Chaptec, QC, Canada) in preparation for fluorescent

microscopyanalysis.

Figure 4.6. Perfusion Set-up

4.5. Fluorescent Microscopy and Area Percent Analysis

Peristaltic Pumps

Models in Parallel (4)

WaterBath @37°C

Each collagen coated or non-coated control model to be analyzed was bisected

longitudinally to expose the inner wall surface. The segments were then placed in a solution of

mepacrine (quinacrine dihydrochloride, Sigma-Aldrich Inc, MO, USA) at a concentration of 100

mM. Mepacrine concentrates in platelet granules and fluoresces when exposed to blue Iight. After

90 minutes, individual segments are removed, dip-rinsed in de-ionized water to remove any

residual mepacrine and imaged using a inverted light microscope with fluorescent attachment

(Leica DM IL, Leica Microsystems, UK). For analysis purposes, ail models were marked on the

21

Page 29: Platelet Adhesion in an Asymmetric Stenosis Flow Model · 1. Introduction Cardiovascular disease is any abnonnal condition characterized by the dysfunction of the heart or blood vessels

model wall to indicate the 5 different regions as shown in figure 4.7. It should be noted that

although the straight models do not have a 'peak' region, one was included for comparison

purposes.

Peak

Inlet Proximal Distal Outlet

1----------- 4 cm ----------1

Figure 4.7. Regional Model Separation

Three randomized pictures at 4X magnification of the inlet, proximal, peak, distal and outlet

sections were taken of each model half using a digital camera (Leica De 300, Leica

Microsystems, UK) linked to Adobe®Photoshop® software. Overall a total of 30 pictures were

taken of each model.

These pictures are then analyzed for percent area coverage using ImageJ® (National

Institute of Health, USA) and Adobe®Photoshop®. This was do ne by first converting each color

Photoshop picture to grays cale tiff format (Figure 4.8)

(a) (b)

Figure 4.8. (a) Color Fluorescent Microscope Image (b) Converted Grayscale Image

22

Page 30: Platelet Adhesion in an Asymmetric Stenosis Flow Model · 1. Introduction Cardiovascular disease is any abnonnal condition characterized by the dysfunction of the heart or blood vessels

The grayscale image could then be easily analyzed using ImageJ® to come up with an area

percent platelet coverage value for each picture. A final area percent coverage was obtained for

each region by taking the average of the results for all six pictures. Area percent results were then

normalized based on the inlet values before analysis to easily compare multiple experiments and

eliminate any differences caused by different PRP concentrations and platelet interaction due to

using blood from different pigs in each experiment. Nonnalization was done by converting area

percent values (A) to relative values (R) using the following fonnula for each model;

R=~ X AInlet

(4.1)

where the subscript X represents any of the five regions.

4.6. Radiolabelling and Gamma Counter Analysis

4.6.1. Radiolabelling Platelets

ln sorne experiments, platelets were radiolabelled by adding an extra step to the isolation

procedure. Following the aspiration of citrate from the centrifuged platelet and citrate buffer

solution, two ml's of citrate buffer were added to the platelet pellet along with 250 fJCi"'ln

(Amersham International, UK). This mixture was left to incubate for 15 minutes in a fume hood

to allow time for platelet-IIIIn binding to occur. Unbound "'In along with citrate buffer was then

removed by centrifuging at 2000 rpm for 8 minutes. The supernatant, containing unbound "'In in

citrate buffer, was disposed of and the radiolabelled platelet pellet resuspended in ppp to make

PRP. Two 50 fJl samples ofPRP were taken into gamma counter tubes before proceeding.

4.6.2. Gamma Coullter

After the perfusion with radiolabelled PRP, the models were dip rinsed in PBS and prepared

for gamma counter (1470 Wallac Wizard, PerkinElmer, USA) analysis. Pirst, the 3D models were

23

Page 31: Platelet Adhesion in an Asymmetric Stenosis Flow Model · 1. Introduction Cardiovascular disease is any abnonnal condition characterized by the dysfunction of the heart or blood vessels

horizontally cut into four 1 cm segments: inlet, proximal, distal and outlet. Note that the earlier

defined peak section was split between the proximal and distal regions in with this experimental

procedure. Each of these segments was then placed into gamma counter tubes containing tissue

fix. The tubes were positioned in the gamma counter trays along with the two PRP samples,

making a total of 18 tubes. Count per minute (Cpm) results were then obtained for each model

region and the PRP samples. To come up with adhered platelets per mm2 (Plt/mm2) values for

each region the foUowing calculations had to be made. First, the number of platelets per Cpm

(Plt/Cpm) is ca1culated from the Cpm for sample PRP (CpmPRP) and the final PRP platelet

concentration (PRPP1t)

PRPplt Plt/Cpm Cpm *1000/

PRP /50

followed by the subsequent equation involving segment length (l) and diameter (D)

Plt/mm 2 Cpmsegment *Pltj *100 1liD jCpm

(4.2)

(4.3)

Results for each section of aU four models could then be easily compared on a per square mm

basis.

4.6.3. Rlank Radioactive Solution Test

To determine if Sylgard l84® models were picking up any residual lllIn that may have

been left in the PRP solution, the following procedure was employed. First, 10 !lCi of JUIn was

mixed with 2 ml of deionized water. One ml of this solution was then injected into a non-coated

straight model and left inside for 15 minutes, rotating 1800 once. After this time period, the

solution was drained, model dip rinsed in PBS and placed in tissue fix for 10 minutes. The model

was then removed, cut into Il mm sections and each section placed in a centrifuge tube to be

analyzed with the gamma counter.

24

Page 32: Platelet Adhesion in an Asymmetric Stenosis Flow Model · 1. Introduction Cardiovascular disease is any abnonnal condition characterized by the dysfunction of the heart or blood vessels

4.7. Statistical Analysis

Statistical analysis was perforrned using GraphPad Prism TM software. Two way analysis

of variance (ANOV A) followed by Bonferroni post testing with a 95% confidence interval was

used to compare both model and regional results. P values less than 0.05 were considered

statistically significant.

25

Page 33: Platelet Adhesion in an Asymmetric Stenosis Flow Model · 1. Introduction Cardiovascular disease is any abnonnal condition characterized by the dysfunction of the heart or blood vessels

5. ResuIts

5.1. Collagen Coating Verification

To verify the presence of collagen, ATR-FfIR analysis was conducted. Figure 5.1 shows

the results for non-coated and collagen coated Sylgard 184®.

~ _aBER ,.....

<'4 .....

~

CI) ;t::\' <X) c: 0 :::::l 0:::

~ c.o ci

~ 0

<'4 10

~ 0

4000 3500 3000 2500 2000 1500

Wavenumber cm- '1

Figure 5.1. FTIR Spectrum of Sylgard 184® (Blue) and Collagen Coated Sylgard 184® (Red)

Only peaks at wavelengths > 1400 cm- l were analyzed for both spectrums since peaks less than

this are generally considered inelevant for identification purposes. The Sylgard 184® spectrum

exhibited two important peaks; a sharp strong peak around 2950 cm- l and sharp medium peak at

1400 cm- I. As expected, Sylgard 184® coated with collagen resulted in a similar pattern to blank

Sylgard 184® but with a few extra peaks. The spectrum contained three weak broad peaks around

26

Page 34: Platelet Adhesion in an Asymmetric Stenosis Flow Model · 1. Introduction Cardiovascular disease is any abnonnal condition characterized by the dysfunction of the heart or blood vessels

1600 cm- l and single weak broad peak at 3300 cm- l additional to the same two sharp peaks at

2950 cm- l and 1400 cm- l.

To further verify that the extra peaks in the coated spectrum were from collagen, we

subjected Sylgard 184® to the same coating procedure but with de-ionized water only (figure

5.2).

if) .... c; ::l 0::: ~

0 N

I.t? .,-

0

1,()

o

o ci

3500 3000 2 !;.Q 0 2000 1500

Wavenumber cm-' Figure 5.2. FTIR Spectrum of Sylgard 184® (Blue) Coated with De-ionized Water

Comparing to figure 5.1 we see that the peaks identified to be from a protein in the collagen

coated spectrum are not present in the de-ionized water spectrum and the only peak present is the

same sharp strong peak observed at 2950 cm-1 as in both other spectrums.

27

Page 35: Platelet Adhesion in an Asymmetric Stenosis Flow Model · 1. Introduction Cardiovascular disease is any abnonnal condition characterized by the dysfunction of the heart or blood vessels

5.2. Platelet Rich Plasma Properties

Prior to the experiments, the PRP concentration for all experiments was deterrnined (table

5.1). Platelet count per minute was also measured for the gamma counter experiments.

Method # PRP Concentration (d06/mI) PIt/Cpm Gamma Counter 1 141 83

2 239 372 3 241 284

Fluorescent Microscopy 1 201 2 257 3 296 4 297 5 252 6 272 7 243

Table 5.1. PRP platelet concentration and platelet per count per llÙnute (gamma counter analysis only) data for ail 10 perfusion experiments. * The cell counter used is considered to be accurate within +/- 10 %

Bach of the PRP platelet counts for the fluorescence experiments fell within the 200-300 million

platelets per ml range but the first gamma counter experiment concentration fell below at 141

million platelets per ml. Although this was not in our specified range, the experiment was still

deemed valuable for analysis purposes. In general, the coefficient of variation for the gamma

counter and fluorescent experiments was 27.6 % and 12.8 %, respectively.

5.3. Gamma Counter

Following perfusion, models to be analyzed with the gamma counter were cut into lOmm

segments corresponding to the four regions of interest: inlet, proximal, distal and outlet. Count

per minute data was obtained from the gamma counter and corresponding adhered platelets per

square mm results calculated. Both sets of data, for the straight and stenosis models, are shown in

tables 5.2 and 5.3, respectively.

28

Page 36: Platelet Adhesion in an Asymmetric Stenosis Flow Model · 1. Introduction Cardiovascular disease is any abnonnal condition characterized by the dysfunction of the heart or blood vessels

# Collagen Coated Model [Cpm/(Pltlmm1)] 1 [14.9/1312] [4.9/431] [8.0/704]] [1.8/158] 2 [22.4/8861] [45.8/18040] [38/14996] [40.7/16089] 3 [582.1/175316] [35.9/10823] [96.2/28965] [47.8/14397]

# Non Coated Model [Cpm/(Pltlmm2)] 1 [21.5/1892] [21.6/1901] [28.9/2544] [4.9/431] 2 [38.4/15167] [62.9/24713] [47.9/18906] [46.3/18288] 3 [97.6/29387] [55.1116586] [42.5/12801] [67.9/20441]

I:nlet Proxhnal Distal Outlet

Table 5.2. Count per minnte and adhered platelets per square mm data for both the collagen coated and non­coated straight models

For the collagen coated straight model (runs 1, 2 and 3) the platelet per square mm coefficient of

variation values were 75.7%, 27.4% and 137.7%, respectively. Resultant mean values for each

run were 651, 14501 and 57375. The corresponding coefficient of variation for the non-coated

model were 52.8%,20.7% and 35.9%, and, similarly, ca1culated mean values were 1692, 19268

and 19804.

# Collagen Coated Model [Cpm/(Pltlmm1)] 1 [51.8/4560] [39.4/3998] [17.9/1816]] [30.3/2667] 2 [34.8/13732] [33.4/15192] [25.9/11777] [10.5/4715] 3 [75.3/22690] [70.2/24362] [44.3/15381] [50.7/15281]

# Non Coated Model [Cpm/(Pltlmm1)] 1 [17.2/1514] [26.5/2689] [12.9/1309] [28.2/2482] 2 [41.5/16405] [44.1120094] [28.0/12749] [27.6/10901] 3 [59.1117791] [53.0/18390] [41.5/14397] [65.3/19658]

Inlet Prox:i:J:nal Distal Out:let

Table 5.3. Average count per minute and adhered platelets per square mm data for both the collagen coated and non-coated stenosis models.

For the collagen coated stenosis model (runs 1,2 and 3) the platelets per square mm coefficient

of variation values were 38.3%, 43.8% and 24.6%, respectively. Subsequent mean values for

each run were found to be 3260, 11216 and 19428. The corresponding coefficient of variation

29

Page 37: Platelet Adhesion in an Asymmetric Stenosis Flow Model · 1. Introduction Cardiovascular disease is any abnonnal condition characterized by the dysfunction of the heart or blood vessels

for the non-coated model are 34.4%, 27.1 % and 12.8% and, similarly, calculated mean values

were 1998, 15037 and 17559.

Adhered platelet values were also converted to normalized data relative to the inlet value

for each of the runs in the same manner as for the fluorescent microscopy analysis experiment.

Figure 5.2 shows the results.

1.600

1.400 ! E

1.200 ;:j 0 '" '" ~ ,. p ~ ~ '"

u 1.000 Q) -......

'-. -~ .... 0.800 <Il

5:: "0 _.+. - StraighCCoated ~ 0.600 N .... • Stenosis_Coated -<Il

ê 0.400 ... + ., StraighCNonCoated ~ II Stenosis_NonCoated

0.200

0.000

In let Proximal Distal Outlet

Figure 5.2. Normalized adhered platelet average for the ail the ruus (+/. std error). (N=3)

For this normalized data, a number of points in the proximal, distal and outlet regions were

outside standard error of each other.

5.3.1. Blank Solution Results

The blank radioactive solution test completed to determine whether the Sylgard 184®

model was picking up residual lllIn gave the following Cpm results for the four segments:

312535,243897,410614 and 285077, giving an average of 313013.

30

Page 38: Platelet Adhesion in an Asymmetric Stenosis Flow Model · 1. Introduction Cardiovascular disease is any abnonnal condition characterized by the dysfunction of the heart or blood vessels

5.4. Fluorescent Microscopy Analysis

The gamma counter results were biased by Slygard 184® picking up residual

radioactivity. Fluorescent microscopy analysis was used to visualize and quantify attachment.

5.4.1. Sam pie Pictures

A wide range of platelet adhesion was seen amongst the experiments analyzed using the

fluorescent microscope and this is illustrated by figure 5.4. The bright green circular objects are

fluorescing platelets and the surrounding black background is non-fluorescing Slygard 184®.

(a) (b)

Figure 5.4. Fluorescent microscope image (a) High platelet adhesion (b) Low platelet adhesion

5.4.2. Area Percent Coverage

Figures 5.4 (a) and (b) resulted in platelet area percent coverage of 5.000% and 0.522%,

respectively. OveraU, the range of coverage for aU the images from the fluorescence microscope

analyzed experiments was 0.064 - 5.109%. The average area percent coverage, standard deviation

and coefficient of variance were calculated for each model and are shown in table 5.4.

Model Mean (%) Standard Coefficient of Deviation Variance (%)

Straight Coated 1.18 0.90 42.57 Stenosis Coated 1.13 1.09 39.91

Straight Non-Coated 1.19 0.99 39.42 Stenosis Non-Coated 1.06 0.93 36.40 Table 5.4. Mean platelet area percent coverage and corresponding standard deviation and coefficient of variance for each model (N=7)

31

Page 39: Platelet Adhesion in an Asymmetric Stenosis Flow Model · 1. Introduction Cardiovascular disease is any abnonnal condition characterized by the dysfunction of the heart or blood vessels

Adhesion results obtained from the fluorescent microscope experiments were analyzed to

determine if overall average platelet coverage was significantly different between the four

models, stenosis coatedlnon and straight coatedlnon. The peak was left out of analysis since it

overlaps proximal and distal regions. 2-way ANOV A analysis with Bonferroni post testing

showed that neither coating nor type of geometry had an effect on platelet adhesion.

5.4.3. Regional Comparison

The fluorescent values were normalized by the inlet value of each model to reduce the

error associated with PRP concentration, staining and imaging. Figure 5.5 shows the regional

results.

3.00 - ... - StraighC Collagen

• Stenosis_Collagen il 2.50 co el cu ;;.-

- ...... - Straight_Non-Coated III Stenosis_Non-Coated

0 2.00 u ....

cu ...... cu .... ro

1.50 ç;:; "'0 cu N ..... ......

ê 1.00

i 0.50

0.00 -----~--~ ---1

In let Proximal Peak Distal Outlet

Figure 5.5. Normalized platelet coverage for each region of each model (+/- std error). (N=7)

32

Page 40: Platelet Adhesion in an Asymmetric Stenosis Flow Model · 1. Introduction Cardiovascular disease is any abnonnal condition characterized by the dysfunction of the heart or blood vessels

Next question to be determined was whether the different regions of each model had a significant

effect on platelet adhesion. Adhesion varied significantly with location in the coated stenosis

model (2-way ANOV A, Bonferroni post test). Table 5.5 summarizes the results.

Model Straight Stenosis Straigbt Stenosis Res.i°ns Coated Coated Non-Coated Non-Coated

Inlet ns ns ns ns Proximal

Inlet ns ns ns ns Peak Inlet ns ** ns ns Distal Inlet ns ns ns ns

Outlet Proximal ns ns ns ns

Peak Proximal ns * ns ns

Distal Proximal ns ns ns ns

Outlet Peak ns * ns ns Distal Peak ns ns ns ns

Outlet Distal ns ns ns ns Outlet

Table 5.5. Comparison of average overall adhesion for each of the model variations. ns-Not Significant (p value> 0.05) * Significant (p value < 0.05) ** Very Significant (p value < 0.001)

The distal segment showed a significant difference in adhesion of platelets in the collagen coated

model. This region exhibited significantly greater normalized platelet coverage than the inlet,

proximal and peak regions of the mode!. More specifically the distal region compared to the inlet

region had a p-value less than 0.001, while the distal compared to the proximal and peak region

had p-values less than 0.05.

33

Page 41: Platelet Adhesion in an Asymmetric Stenosis Flow Model · 1. Introduction Cardiovascular disease is any abnonnal condition characterized by the dysfunction of the heart or blood vessels

6. Discussion

Tubular, 3D, asymmetric stenosis and straight coronary artery models were used to

investigate the relationship between platelet adhesion and flow patterns and resulting shear stress.

Very few researchers have attempted to study this relationship using tubular models in the past

due to the difficulty in building models and analyzing the results. However, traditional cone and

plate and parallel plate models cannot accurately reproduce coronary hemodynamics. The

challenges associated with these models were understood and appreciated very soon into the

study. In particular, our initial analysis method utilizing the gamma counter was shown to be

erroneous due to the models picking up residual radiation and, consequently, skewing the results.

We were able to overcome this challenge and achieve significant results by utilizing fluorescent

platelet labelling and imaging techniques. With this method we showed that platelets under flow

are significantly more likely to adhere to the distal region of our 75% asymmetric stenosis

collagen coated model than the inlet, proximal and peak regions. This result emphasizes the

significance of this region in the initiation of coronary heart disease.

6.1. Coating Verification

To verify that the protein coating procedure was working we analyzed collagen coated

and uncoated model samples with ATR-FTIR. The uncoated Sylgard 184® spectrum showed a

sharp strong peak around 2950 cm-1 and sharp medium peak at 1400 cm-l, likely corresponding to

-CH- and -CH2 stretching, respectively (Lambert et al., 1999). As expected, Sylgard 184® coated

with collagen resulted in a sirnilar pattern to blank Sylgard 184® but with a few extra peaks

(figure 6.1). The three weak broad peaks around 1600 cm-1 and single weak broad peak at 3300

cm- I suggest that the sample contains amide (-CONH2) bonds (Lambert et al., 1999). The peaks

at 1600 cm-1 are likely due to the C=Û stretching and -NH2 deformation, while the peak at 3300

34

Page 42: Platelet Adhesion in an Asymmetric Stenosis Flow Model · 1. Introduction Cardiovascular disease is any abnonnal condition characterized by the dysfunction of the heart or blood vessels

cm- I may be from _NH2 stretching (Lambert et al., 1999). When further comparing the collagen

coated spectrum to the de-ionized water coated Sylgard 184®spectrum we see that the later shows

only one sharp strong peak around 2950 cm- I and none of the peaks identified as a protein.

Overall, both of these observations clearly identifies a protein in the collagen spectrum only and

confirms that collagen is coated on the model surface.

6.2. Fluorescence Microscopy Imaging

We decided to use mepacrine labelling and fluorescent ffiICroSCOpy to analyze our

adhesion results as it allowed for visual confirmation and quantification of adhesion. A number

of other researchers have used this method in the past and come to sorne interesting conclusions.

For instance, Ruggeri et al. (2006) perfused whole blood containing mepacrine labelled platelets,

at shear rates ranging from 3000 S-I to 24000 s-l, over a parallel plate flow chamber coated with

collagen. To analyze the results they either captured video during the perfusion or imaged

adhered platelets immediately after. They concluded that, under their experimental conditions,

shear rates must exceed 10000 S-1 for platelets to aggregate and, furthermore exceed 20000 S-1 for

these aggregates to be stable. Another research group, Goto et al. (2004, 2006) used a similar

technique to look at the effect of different drugs on thrombi formed on collagen coated surfaces.

They were able to show that a number of drugs could dissolve thrombi, giving hope to possible

use of these drugs in the treatment of coronary heart disease. Although we don't necessarily agree

with the first studies results, both findings gave us the confidence that this analysis technique

would be useful to our study and could achieve significant results.

6.3. Model Comparison

It's difficult to compare our results to other in-vitro platelet studies since the geometry

and model design is unique to work in the area. To overcome this, we must compare with

35

Page 43: Platelet Adhesion in an Asymmetric Stenosis Flow Model · 1. Introduction Cardiovascular disease is any abnonnal condition characterized by the dysfunction of the heart or blood vessels

multiple studies that have sorne of the same features. To start, our results showed that there was

no significance difference in overall platelet adhesion amongst any of the model types. This

suggests that neither the coating nor geometry had an effect on overall platelet adhesion. When

beginning our experiments we had theorized that coating with collagen, a thrombus promoting

substrate, would allow for increased platelet adhesion when compared to the Sylgard 184® model

surface. This was not the case as our results in table 5.4 and figure 5.5 c1early show. No other

study has been published using Sylgard 184® as the substrate but we can refer to other studies

that use a glass substrate. Chandy et al. (1998) looked at platelet adhesion to glass slides, protein

coated and uncoated, via perfusions with blood, PRP and washed platelets. When using blood or

PRP as the perfusion fluid, they found that the glass slides had more platelet adhesion and

spreading when compared to collagen coated slides. When they used washed platelets as the

perfusion fluid, they found the opposite to be true. Other studies, such as Zaidi et al. (1996), have

found that collagen coated glass demonstrated more platelet adhesion than plain glass, but others,

like Chandy et al. (1998) using blood and PRP, illustrate the opposite. Our study just happens to

faIl in the middle of the debate. Perhaps most importantly, it shows the variability found in past

studies done in this area and emphasizes the importance of using experimental conditions that

emulate physiological conditions as best possible.

Overall adhesion was not significantly affected by stenosis geometry (table 5.4). The

regional data shown in figure 5.5 shows there is significant variation in platelet adhesion in the

stenosis model with collagen coating. But, when looking at overall platelet adhesion in the

model, this increase was not large enough to cause significant variation in total adhesion. The

distal region of the stenosis coIlagen coated model showed significantly more normalized platelet

area coverage than the inlet, proximal and peak regions (figure 5.5 and table 5.5). And, although

not statistically significant, there was a trend towards increased platelet adhesion compared to the

36

Page 44: Platelet Adhesion in an Asymmetric Stenosis Flow Model · 1. Introduction Cardiovascular disease is any abnonnal condition characterized by the dysfunction of the heart or blood vessels

outlet region. If adhesion is more likely with low WSS, our expected order of platelet adhesion,

beginning with the highest, for each region wou Id be as follows: Distal, outlet, inlet, proximal,

peak. This rank is what we found except the inlet region had lower platelet adhesion than the

proximal and peak regions and the difference between distal and outlet platelet adhesion wasn't

significant.

When analyzing lower than expected inlet adhesion more c10sely we come to a few other

theories about this result. PRP flows into the model and makes contact with the inlet region

before any of the others. It' s possible that this initial contact will activate platelet receptors for

collagen and make them more liable to adhere to the model further downstream. The inlet region

would thus be activating platelets and, although sorne platelets adhere in the region, most will

adhere to the regions downstream, resulting in lower than expected platelet adhesion. Another

hypothesis for this result is that platelets do not adhere as soon as they contact an adhesive

substrate, they actually exhibit rolling and translocation. Savage et al. (1998) used confocal

imaging to view platelets in blood perfused at varying shear rates over a collagen coated parallel

plate perfusion chamber. They found that vWf must first bind to collagen, exposing vWf's

collagen binding site, before platelets can tether to the collagen wall via vWf. Platelets will then

roll over vWf in the direction of flow until they reach stable arrest. Under a number of different

conditions they found a large number of platelets, up to 90% of platelets in one experiment,

exhibit translocation following initial tethering with vWf. This suggests that, in our study,

platelets may initially tether to collagen via vWf in the inlet section but a large number of those

will translocate downstream before reaching stable arrest. Ultimately, resulting in lower than

expected platelet adhesion in the region.

As discussed in section 3.3 and suggested by numerous previous studies, high shear stress

increases platelet activation. Consequently, platelets activated in the high shear regions (proximal

37

Page 45: Platelet Adhesion in an Asymmetric Stenosis Flow Model · 1. Introduction Cardiovascular disease is any abnonnal condition characterized by the dysfunction of the heart or blood vessels

and peak) may show increased adhesion in the regions that follow the stenosis: distal and outlet.

Overall, the importance of the finding that platelet adhesion is greatest in the distal region must

not he understated as it could lead to the development of better treatments for cardiovascular

disease. For example, this is the first study to show that a thrombus may initialize post-stenotic,

suggesting a geometric factor to plaque stability.

Referring back to the literature review we find a number of other studies that have shown

similar results when looking at platelet adhesion in a distal or pseudo distal region. Bluestein et

al. (1997) perfused blood through an axisymmetric stenosis model and found platelet adhesion to

be greatest in the distal region of their model, particularly in periods of recirculation.

Schoephoerster et al. (1993) also came to a similar conclusion about increased platelet adhesion

the distal region of their own axisymmetric model. Another interesting study do ne by Zhang et

al. (2002) using a cone and plate viscometer showed that platelets become activated by a short,

high shear pulse and will adhere and aggregate only if this pulse is followed by a period of low

shear stress. This is very similar to the type of condition we find in stenotic arteries. The

occlusion creates a high shear pulse and the distal region gives platelets the opportunity to adhere

and aggregate in this low shear area.

Unfortunately, aIl of these models still have a number of limitations. Both the

Schoephoerster et al. (1993) and Bluestein et al. (1997) study use an axisymmetric stenosis. Ojha

et al. (2001) studied the morphology of 17 right coronary arteries (ReA' s) and found that 71 %

(12/17) showed eccentric intimaI thickening of the proximal region. A stenosis geometry very

similar to our asymmetric model. Schoephoerster et al. (1993) used Lexan models with no

coating and Bluestein et al. (1997) used glass models also with no coating. Our results clearly

show that only the collagen coated stenosis exhibit any regional variation. By not having any

38

Page 46: Platelet Adhesion in an Asymmetric Stenosis Flow Model · 1. Introduction Cardiovascular disease is any abnonnal condition characterized by the dysfunction of the heart or blood vessels

component of the vessel wall in contact with blood or PRP flow, they leave out important

platelet-substrate interactions that would be occurring.

To date our study is the most progressive in the area and the hope is that ifs only the start

of many as we work our way towards replicating in-vivo conditions in platelet adhesion and

thrombus formation in-vitro experiments.

39

Page 47: Platelet Adhesion in an Asymmetric Stenosis Flow Model · 1. Introduction Cardiovascular disease is any abnonnal condition characterized by the dysfunction of the heart or blood vessels

7. Conclusions

A 3D coronary stenosis model of platelet adhesion was developed and tested. With

this method it was shown that platelets under flow are significantly more likely to adhere to the

distal region of our 75% stenosis collagen coated models than the inlet, proximal and peak

regions of that model. This regional adhesion difference was not shown when collagen was not

present. Possible reasons for this are as follows:

• The distal region follows a high shear pulse that may activate platelets

• Low wall shear rates and flow recirculation zones in the region allow platelets to

adhere to the vessel wall

o verall , the results give us a better understanding of the effect of complex flow and shear

conditions on platelet adhesion, activation and thrombus formation. And, perhaps most

importantly, they emphasize the value of investigating local flow conditions when studying the

initiation of heart attacks and strokes.

40

Page 48: Platelet Adhesion in an Asymmetric Stenosis Flow Model · 1. Introduction Cardiovascular disease is any abnonnal condition characterized by the dysfunction of the heart or blood vessels

8. Limitations and Future Work

8.1. Radioactive Platelet Adhesion

A number of researchers investigating platelet adhesion have used the gamma counter

technique to come to sorne interesting conclusions. For example, the previously mentioned

Schoephoerster et al. (1993) study perfused a PRP solution containing I11In labelled platelets

through 4 different model types. With the use of a gamma counter they found platelet adhesion

density to be greatest in observed periods of flow recirculation and reattachment, and to be least

in locations of high shear and flow separation when running perfusions at peak shear rates (S-I) of

1312, 3926 and 7872. Unfortunately, we were unable to produce reliable results such as these

with our experiments due to the discovery that Sylgard 184® models may have been picking up

residual radiation remaining in the PRP solution. This was realized after injecting blank

radioactive solution into a straight model, letting the model sit, rinsing and fixihg, and using the

gamma counter to obtain Cpm results. An average Cpm of approximatély 300000 clearly

indicated the models capacity to absorb residual radiation. This is likely due to IllIn molecules

fitting into pores found on the model surface. Removal of the molecules would require significant

agitation and cleaning of the surface. Doing this wou Id not be feasible following perfusions since

platelets are adhered to the surface and would be removed in the process.

8.2. Fluorescence Microscopy Imaging - Protocol Development

One of the main reasons for choosing fluorescent microscopy imaging was so we could

visually verify that significant platelet adhesion was occurring which was not possible with the

use of a gamma counter. One perceived problem with using this method is that platelets may be

aggregated and thus stacked on top of each other making it difficult to gain information about the

actual number of platelets in one location. This is very much true and in aH likelihood we are

41

Page 49: Platelet Adhesion in an Asymmetric Stenosis Flow Model · 1. Introduction Cardiovascular disease is any abnonnal condition characterized by the dysfunction of the heart or blood vessels

only seeing aggregates adhered to the surface due to the large size of the fluorescing particles.

Nonetheless area percent analysis gives us a good idea of the relative number of platelets

adhered. This can be further carried forward to explain the reason for normalizing the data based

on the inlet platelet area percent coverage of each model. Since we are only getting relative

platelet coverage data, normalizing, which is essentially further converting to relative data,

doesn't adversely affect the results. Also, normalization helped to eliminate adhesion differences

that may have occurred from using blood taken from various pigs and having different PRP

platelet counts for each of our experiments.

8.3. ln-vitro Model

Although the use of 3D, tubular models to analyze platelet adhesion in coronary arteries is

lessening the gap between in-vitro experiments and physiological conditions, additional

modifications could be made to gain even more accuracy.

8.3.1. Geometry

The inclusion of an asymmetric stenosis within our 3D models was a real step forward but

still does not fully represent the complexity of human coronary arteries. Our 4 cm model was

straight, but in reality you will not find any region in the coronary arteries that is straight over

this length. An illustration of the heart and main coronary arteries is shown in figure 8.1. It is

quite clear that coronary ruteries bend and curve to accommodate the contours of the heart muscle

and consequently, the model should attempt to represent the average geometrical structure as best

possible. A right coronary artery model cast from an actual patient heart has been developed in

our lab and could be used in future experiments on platelet adhesion.

42

Page 50: Platelet Adhesion in an Asymmetric Stenosis Flow Model · 1. Introduction Cardiovascular disease is any abnonnal condition characterized by the dysfunction of the heart or blood vessels

Figure 8.1. Diagram of the Heart and Coronary Arteries (Texas Heart Institute)

8.3.2. Model Coating

The use of a complete human vessel wall would be the ideal for this study but it is

extremely complex and difficult to replicate in-vitro. Nevertheless, an attempt should be made to

incorporate the most important components when looking at platelet-vascular lining interactions.

Future work in this study should begin with the inclusion of endothelial cells and other wall

proteins such as fibrinogen. The inclusion of endothelial ceUs may be of particular importance

since the se celIs have been shown to release vWf, at sites of inflammation that is larger and

stickier than regular plasma vWf. This particular type of vWf increases adhesion in situations

similar to our in-vitro study.

8.3.3. Model Compliance

Vessels in the body respond to changing physiological conditions by contracting,

expanding and bending appropriately. Our tubular Sylgard 184® in-vitro models were designed to

accommodate similar conditions found in-vivo. Unfortunately, our experiments were unable to

fully replicate the complex action of a pumping heart. Future work should attempt to alleviate

this concem.

43

Page 51: Platelet Adhesion in an Asymmetric Stenosis Flow Model · 1. Introduction Cardiovascular disease is any abnonnal condition characterized by the dysfunction of the heart or blood vessels

8.4. Experimental Conditions

A number of different factors can be improved upon with the actual running of our

experiments.

8.4.1. Perfusate

Using PRP as our perfusion fluid worked well because we were able to avoid

complications that may have occurred with the use of whole blood during perfusion and after

when analyzing adhesion results. For instance, not only wou Id platelets be adhering to our model

but so would neutrophils and other blood components. These additional components would create

complexities when trying to determine platelet area percent coverage via fluorescence

microscopy. However, the different interactions that would occur by using whole blood may have

given different, more physiological accurate results and any future research in this area should try

to work with the difficulties created in order to better replicate physiological conditions.

Furthermme, using pig blood to produce PRP used in our experiments could c1early be

improved upon with the use of human blood. For instance, pig plasma has a significantly higher

viscosity then human plasma according to Windberger et al. (2003). Due to this and other

dissimilarities, future work should involve human blood.

8.4.2. Circulation

In our study, a peristaltic pump was used to circulate PRP through our models. This type

of pump uses rotating rollers to push fluid through the rubber tubing and downstream. Previous

researchers such as Jesty et al. (2003) have shown that this roller action can increase platelet

activation. Another limitation of this pump is that it creates a steady flow. The ideal flow

condition for any blood flow experiments wou Id be pulsatile flow that simulates the hearts

pumping action. Both of these limitations highlight the drawback with using this type of pump

44

Page 52: Platelet Adhesion in an Asymmetric Stenosis Flow Model · 1. Introduction Cardiovascular disease is any abnonnal condition characterized by the dysfunction of the heart or blood vessels

for platelet activation and adhesion studies. These issues were known prior to beginning the

experiment but no viable alternative was found to exist. Future workers on this project should be

aware of the problem and be continually searching for new pumping technology that may

improve on the current method.

The use of different reservoirs for each of the models has recently been brought into

question. By having separate reservoirs, platelets that are activated by perfusion through the

stenotic models, are re-circulated through the same stenotic model. At first thought this appears

to be the correct methodology but when relating it to physiological conditions, it may actually be

better to have a single reservoir. This would be closer to reality since an blood is pumped through

a central chamber, the heart, in the body.

8.5. Experimental Justification

Many limitations of our study have been presented in this section and could make sorne

question its significance. Consequently, it's important to rémember why this study improves on

previous work done in the area. We used an asymmetric stenotic artery model that has been

shown to best represent the eccentric geometry found in diseased arteries. By using this model

and keeping the other conditions, although not truly physiologie al accurate, similar to most

experiments in the area, we were able to isolate the geometric effect. Ultimately showing that

flow patterns created by an asymmetric stenosis directly contributes to thrombus formation.

45

Page 53: Platelet Adhesion in an Asymmetric Stenosis Flow Model · 1. Introduction Cardiovascular disease is any abnonnal condition characterized by the dysfunction of the heart or blood vessels

9. References

Andrews, R. K; Lopez, J. A; Berndt, M. C. Molecular Mechanisms ofPlatelet Adhesion and Activation. Int. J. Biochem. Cell Biol 1997, 29,91-105.

Badimon, L.; Badimon, J. J.; Galvez, A; Chesebro, J. H.; Fuster, V. Influence of arterial damage and wall shear rate on platelet deposition. Ex vivo study in a swine model. Arteriosclerosis. 1986, 6,312-20.

Barstad, R. M.; Kierulf, P.; Sakariassen, K. S. Collagen Induced Thrombus Formation at the Apex of Eccentric Stenoses--a Time Course Study With Non-Anticoagulated Human Blood. Thromb Haemost. 1996,75,685-692.

Barstad, R. M.; Orvim, D.; Hamers, M. J.; Tjonnfjord, G. E.; Brosstad, F. R.; Sakariassen, K. S. Reduced Effect of Aspirin on Thrombus Formation at High Shear and Disturbed Laminar Blood Flow. Thromb Haemost. 1996,75,827-832.

Barstad, R. M.; Roald, H. E.; Cui, Y.; Turitto, V. T.; Sakariassen, K. S. A Perfusion Chamber Developed to Investigate Thrombus Formation and Shear Profiles in Flowing Native Human Blood at the Apex ofWell-Defined Stenoses. Arterioscler Thromb 1994, 14, 1984-1991.

Brown, B. G.; Bolson, E. L.; Dodge, H. T. Dynamic mechanisms in human coronary stenosis. Circulation. 1984,70, 917-22.

Bluestein, D.; Niu, L.; Schoephoerster, R. T.; Dewanjee, M. K. Fluid Mechanics of Arterial: Relationship to the Development of Mural Thrombus. Ann. Biomed. Eng 1997,25, 344-356.

Canadian Heart and Stroke Foundation. Incidence of Cardiovascular Disease, 2002. [Online] Available http://ww2.heartandstroke.caIPage.asp?PageID=24. June 8, 2007.

Italiano, J. E., Jr.; Lecine, P.; Shivdasani, R. A; Hartwig, J. H. Blood Platelets Are Assembled Principally at the Ends of Proplatelet Processes Produced by Differentiated Megakaryocytes. J. Cel! Biol 1999, 147, 1299-1312.

Chandy, T.; Mooradian, D. L.; Rao, G. H. Platelet Adhesion and Spreading on Protein-Coated Surfaces: Variations in Behavior in Washed CeUs, PRP, and Whole Blood. J. Biomater. Appl. 1998,13,46-65.

Davis, C.; Fischer, J.; Ley, K; Sarembock, 1. J. The Role of Inflammation in Vascular Injury and Repair. J. Thromb Haemost. 2003, l, 1699-1709.

de Groot, P. G.; Sixma, J. J. Platelets: Perfusion Chambers. 347-354.2002. Elsevier Science (USA).

Egbrink, M. G.; Van Gestel, M. A.; Broeders, M. A.; Tangelder, G. J.; Heemskerk, J. M.; Reneman, R. S.; Slaaf, D. W. Regulation of Microvascular Thromboembolism in Vivo. Microcirculation. 2005,12, 287-300.

46

Page 54: Platelet Adhesion in an Asymmetric Stenosis Flow Model · 1. Introduction Cardiovascular disease is any abnonnal condition characterized by the dysfunction of the heart or blood vessels

Einav, S.; Bluestein, D. Dynamics of Blood Flow and Platelet Transport in Pathological Vessels. Ann. N. Y. Acad. Sei. 2004,1015,351-366.

Goto, S.; Ikeda, Y.; Saldivar, E.; Ruggeri, Z. M. Distinct Mechanisms of Platelet Aggregation As a Consequence of Different Shearing Flow Conditions. J. Clin. /nvest 1998,101, 479-486. Goto, S.; Tamura, N.; Ishida, H. Ability of Anti-Glycoprotein IlblIlIa Agents to Dissolve Platelet Thrombi Formed on a Collagen Surface Under Blood Flow Conditions. J. Am. Coll. Cardial. 2004,44, 316-323.

Goto, S.; Tamura, N.; Ishida, H.; Ruggeri, Z. M. Dependence of Platelet Thrombus Stability on Sustained Glycoprotein IlblIlla Activation Through Adenosine 5'-Diphosphate Receptor Stimulation and Cyclic Calcium Signaling. J. Am. Coll. Cardial. 2006,47, 155-162.

Heart Function. Texas Heart Institute, St.Luke's Episcopal Hospital. [Online] Available http://texasheart.org/. June 8, 2007

Hemandez, M. R; Tonda, R; Pino, M.; Serradell, M.; Arderiu, G.; Escolar, G. Evaluation of Effects of Rofecoxib on Platelet Function in an in Vitro Model of Thrombosis With Circulating Human BIood. Eur. J. Clin. /nvest 2004,34,297-302.

Huo, Y.; Ley, K F. Role of Platelets in the Developmert of Atherosclerosis. Trends Cardiovasc. Med. 2004,14, 18-22.

Immunology. University of Surrey, School of Biomedical and Molecular Sciences. [Online] Available http://www.surrey.ac.uklSBMSlMicrobialSciences/research/immunology.html. June 8, 2007

Jesty, J.; Yin, W.; Perrotta, P.; BIuestein, D. Platelet Activation in a Circulating Flow Loop: Combined Effects of Shear Stress and Exposure Time. Plate lets. 2003,14, 143-149.

Kaazempur-Mofrad, M. R; Wada, S.; Myers, J. G.; Ethier, C. R Mass Transport and Fluid Flow in Stenotic Arteries: Axisymmetric and Asymmetric Models. Int. J. Beat and Mass Transfer 2005, 4510-4517.

Kaneko, M.; Takafuta, T.; Cuyun-Lira, O.; Satoh, K; Arai, M.; Yatomi, Y.; Ozaki, Y. Evaluation of Platelet Function Under High Shear Condition in the Small-Sized Collagen Bead Column. J. Lab Clin. Med. 2005,146,64-75.

Kieffer, N.; Phillips, D. R. Platelet Membrane Glycoproteins: Functions in Cellular Interactions. Annu. Rev. CeU Biol 1990, 6, 329-357.

Kulkami, S.; Dopheide, S. M.; Yap, C. L.; Ravanat, C.; Freund, M.; Mangin, P.; Heel, K A.; Street, A.; Harper, I. S.; Lanza, F.; Jackson, S. P. A Revised Model of Platelet Aggregation. J. Clin. /nvest 2000, 105, 783-791.

47

Page 55: Platelet Adhesion in an Asymmetric Stenosis Flow Model · 1. Introduction Cardiovascular disease is any abnonnal condition characterized by the dysfunction of the heart or blood vessels

Lambert, J. R; Cooks, R. G.; Lightner, D.; Shurvell, H. F. Introduction to Organic Spectroscopy; Macmillan Publishing Company: New York, 1999.

Leytin, V.; Allen, D. J.; Mykhaylov, S.; Mis, L.; Lyubimov, E. V.; Garvey, B.; Freedman, J. Pathologic High Shear Stress Induces Apoptosis Events in Human Platelets. Bioehem. Biophys. Res. Commun. 2004,320,303-310.

Mates, R. E.; Gupta, R. L.; Bell, A. C.; Klocke, F. J. Fluid Dynamics of Coronary Artery Stenosis. Circ. Res. 1978,42, 152-162.

Maxwell, M. 1.; Dopheide, S. M.; Turner, S. J.; Jackson, S. P. Shear Induces a Unique Series of Morphological Changes in Translocating Platelets: Effects of Morphology on Translocation Dynamics. Arterioscler Thromb Vase Biol 2006, 26,663-669.

National Institutes of Health, Heart Attacks. [Online] Available http://www.nhlbi.nih.govlhealthldcilDiseaseslHeartAttackIHeartAttackWhatIs.htm. June 8, 2007.

Ojha, M.; Leask, R. L.; Butany, 1.; Johnston, K. W. Distribution of IntimaI and Medial Thickening in the Human Right Coronary Artery: a Study of 17 RCAs. Atherosclerosis 2001, 158, 147-153.

Polanowska-Grabowska, R.; Simon, C. G., Jr.; Gear, A. R. Platelet Adhesion to Collagen Type l, Collagen Type IV, Von Willebrand Factor, Fibronectin, Laminin and Fibrinogen: Rapid Kineties Under Shear. Thromb Haemost. 1999,81, 118-123.

Rossi, E. C.; Green, D. A Study of Platelet Retention by Glass Bead Columns ('Platelet Adhesiveness' in Normal Subjects). Br. J. Haematol. 1972,23,47-57.

Ruggeri, Z. M. Old Concepts and New Developments in the Study of Platelet Aggregation. J. Clin. Invest 2000,105,699-701.

Ruggeri, Z. M.; Orje, J. N.; Habermann, R.; Federici, A. R; Reininger, A. J. Activation­Independent Platelet Adhesion and Aggregation Under Elevated Shear Stress. Blood 2006,108, 1903-1910.

Sakariassen, K. S.; Hanson, S. R.; Cadroy, Y. Methods and Models to Evaluate Shear-Dependent and Surface Reactivity-Dependent Antithrombotic Efficacy. Thromb Res. 2001,104, 149-174.

Sakariassen, K. S.; Kuhn, H.; Muggli, R.; Baumgartner, H. R. Growth and Stability of Thrombi in Flowing Citrated Blood: Assessment of Platelet-Surface Interactions With Computer-Assisted Morphometry. Thromb Haemost. 1988,60, 392-398.

Salzman, E. W. Measurement of Platelet Adhesiveness. A Simple in-vitro Technique Demonstrating an Abnormality in Von Willebrand's Disease. J. Lab Clin. Med. 1963,62,724-735.

48

Page 56: Platelet Adhesion in an Asymmetric Stenosis Flow Model · 1. Introduction Cardiovascular disease is any abnonnal condition characterized by the dysfunction of the heart or blood vessels

Savage, B.; Almus-Jacobs, F.; Ruggeri, Z. M. Specifie Synergy of Multiple Substrate-Receptor Interactions in Platelet Thrombus Formation Under Flow. Ce1l1998, 94, 657-666.

Schoephoerster, R T.; Oynes, F.; Nunez, G.; Kapadvanjwala, M.; Dewanjee, M. K. Effects of Local Geometry and Fluid Dynamics on Regional Platelet Deposition on Artificial Surfaces. Arterioscler Thromb 1993, 13, 1806-1813.

Shankaran, H.; Alexandridis, P.; Neelamegham, S. Aspects of Hydrodynamic Shear Regulating Shear-Induced Platelet Activation and Self-Association of Von Willebrand Factor in Suspension. Blood 2003,101,2637-2645.

Virmani, R; Burke, A.P.; Farb, A; Kolodgie, F. D.; Pathology of the Vulnerable Plaque. J Am Coll Cardiol2006, 47, 424-501.

Turitto, V. T.; Baumgartner, H. R. Effect of Temperature on Platelet Interaction With Subendothelium Exposed to Flowing Blood. Haemostasis 1974,3,224-236.

Weeterings, C.; Adelmeijer, J.; Myles, T.; de Groot, P. G.; Lisman, T. Glycoprotein Ibalpha­Mediated Platelet Adhesion and Aggregation to Immobilized Thrombin Under Conditions of Flow. Arterioscler Thromb Vase Biol 2006, 26,670-675.

Windberger, U.; Bartholovitsch, A; Plasenzotti, R; Korak, K. J.; Heinze, G. Whole Blood Viscosity, Plasma Viscosity and Erythrocyte Aggregation in Nine Mammalian Species: Reference Values and Comparison of Data. Exp. Physiol 2003, 88, 431-440.

Wootton, D. M.; Markou, C. P.; Hanson, S. R; Ku, D. N. A Mechanistic Model of Acute Platelet Accumulation in Thrombogenic Stenoses. Ann. Biomed. Eng 2001, 29, 321-329.

Zaidi, T. N.; McIntire, L. V.; Farrell, D. H.; Thiagarajan, P. Adhesion of Platelets to Surface­Bound Fibrinogen Under Flow. Blood 1996, 88, 2967-2972.

Zhang, J. N.; Bergeron, A L.; Yu, Q.; Sun, C.; McBride, L.; Bray, P. F.; Dong, J. F. Duration of Exposure to High Fluid Shear Stress Is Critical in Shear-Induced Platelet Activation­Aggregation. Thromb Haemost. 2003, 90, 672-678.

Zhang, J. N.; Bergeron, A L.; Yu, Q.; Sun, c.; McIntire, L. V.; Lopez, J. A; Dong, J. F. Platelet Aggregation and Activation Under Complex Patterns of Shear Stress. Thromb Haemost. 2002, 88,817-821.

49