4
PM50 - PM50D PERSONAL PROTECTION EQUIPMENT (PPE). LOW FREQUENCY MEASUREMENTS FOR WORKERS AND GENERAL PUBLIC FREQUENCY RANGE 25 Hz - 30 kHz PM50 without display PM50D with display

PM50 - PM50D › public › upload › PM V 01_02 ENG.pdf · PM50 - PM50D PANTONE® 123C PANTONE® BLACK PANTONE® BLACK 80% PANTONE® BLACK 50% x 2x x 2x 2x x area di rispetto assemblaggio

  • Upload
    others

  • View
    18

  • Download
    0

Embed Size (px)

Citation preview

Page 1: PM50 - PM50D › public › upload › PM V 01_02 ENG.pdf · PM50 - PM50D PANTONE® 123C PANTONE® BLACK PANTONE® BLACK 80% PANTONE® BLACK 50% x 2x x 2x 2x x area di rispetto assemblaggio

PM50 - PM50D

PANTONE®123C

PANTONE®BLACK

PANTONE®BLACK 80%

PANTONE®BLACK 50%

x2x

x2x

2x

x

area dirispetto

assemblaggio

costruttivo

pattern

proporzioni

PERSONAL PROTECTION EQUIPMENT (PPE).LOW FREQUENCY MEASUREMENTS FOR WORKERS AND GENERAL PUBLIC

FREQUENCY RANGE25 Hz - 30 kHz

PM50 without displayPM50D with display

Page 2: PM50 - PM50D › public › upload › PM V 01_02 ENG.pdf · PM50 - PM50D PANTONE® 123C PANTONE® BLACK PANTONE® BLACK 80% PANTONE® BLACK 50% x 2x x 2x 2x x area di rispetto assemblaggio

GENERAL SPECIFICATIONS PM50 PM50D

Portable PPE upper limbs PPE waist PPE trunk Logger 24h Programmable from PC PC upgradable Software/Firmware Batteries replaceable by the operator

PM devices allows to monitor and protect the person from the risk of exceeding the exposition threshold for low frequency magnetic fields, through their positioning on the limbs, on the trunk and on the waist. The sensor location individuation on the device allows to place it exactly where needed.

PM50 - PM50D | PERSONAL PROTECTION EQUIPMENT (PPE)

Page 3: PM50 - PM50D › public › upload › PM V 01_02 ENG.pdf · PM50 - PM50D PANTONE® 123C PANTONE® BLACK PANTONE® BLACK 80% PANTONE® BLACK 50% x 2x x 2x 2x x area di rispetto assemblaggio

The small dimensions of the devices allow to insert them in the workers personal protection equipment (PPE), as well as monitoring device for the population.

Through the continuous acquisition we can control all the values of the magnetic field to which the individual is exposed during the activities.

For both version you can set an alarm threshold and if it’s going to be exceeded a red warning led will turn on near the sensors.

TWO VERSION AREAVAILABLE

PM50 WITHOUT DISPLAYPM50D WITH DISPLAY

ALARMTHRESHOLD

AUTOMATICTURN OFF

THREE AXISREADING

50HZSELECTIVE

ALARMENABLING

LOGGERSETTINGS

DISPLAY LINESETTING CONTRAST

MEASURE CHOICE

TIME AND DATE

PM50 - PM50D |

Page 4: PM50 - PM50D › public › upload › PM V 01_02 ENG.pdf · PM50 - PM50D PANTONE® 123C PANTONE® BLACK PANTONE® BLACK 80% PANTONE® BLACK 50% x 2x x 2x 2x x area di rispetto assemblaggio

TECHNICAL SPECIFICATIONS

MPB srlHeadquarters - Place of BusinessLaboratoryVia Giacomo Peroni, 400/402 - 00131 - Roma

T +39 06 41200744F +39 06 41200653

[email protected]

PM50

- PM

50D

01. 0

2

REVISION

* SP

ECIF

ICAT

ION

S M

AY C

HA

NG

E W

ITH

OU

T PR

IOR

NO

TICE

PM 50 PM 50 DSensor type 3 axial magneto-resistive 3 axial magneto-resistiveFrequency responseWithin 1 dBWithin 3 dB

@ Full band38 Hz…...10 kHz25 Hz...…30 kHz

@ Full band38 Hz…...10 kHz25 Hz…...30 kHz

Level rangeResolutionOverloadDynamics

300 nT...…1 mT10 nT 2 mT70 dB

300 nT...…1 mT10 nT 2 mT70 dB

Measurement errorLinearity errorAbsolute error

@ 40…...1000 Hz - 1...…300 µT1.2 dB1.6 dB

@ 40...…1000 Hz - 1...…300 µT1.2 dB1.6 dB

Unit of measurement µT; A/m µT; A/m

User defined measurement mode Selective 50Hz; 50Hz + harmonics;wide band

Selective 50Hz; 50Hz + harmonics;wide band

Data loggerMax recording timeAcquisition time

24 h5…...30 sec

24 h5…...30 sec

Display n.a. LCD 2 lines x 16 characters with led backligthing

Multifunction led indicator Green led - measure in acquisitionRed led - exceeding alarm threshold

Green led - measure in acquisitionRed led - exceeding alarm threshold

I/O Interface USB USB

Sound alarm Programmable threshold from PC software

Threshold from 1µT to 500µTwith step 1µT

Auto turn off n.a. 20min ; 60min; disabledDate and time Programmable from PC Settable by operatorStandards 2004/40/EC directive 2004/40/EC directiveOperating temperature -10° - 40°C -10° - 40°CSensor positions Showed on the case Showed on the case

PowerBattery life

Li-Ion rechargeable (USB powered)48h @ Acq.Time = 30 sec

2 Alkaline AA o 2 Ni-MHrechargeable > 80h

SizeHeight x Width x Depth 70 x 44 x 17 mm 118 x 79 x 25 mm

Accessories USB Interface cable

Programming and data download software

Calibration certificate Standard

Anchor kit Upper limbs, trunk and waist Waist and table/tripod