Posi-Lok Plu s and Panels

In-line plugs makecable extensionsquick and easy

THE SAFEST

ELECTRICAL

SYSTEM FOR

HIGH

AMPERAGE

CONNECTIONS

THE GROUND

ALWAYS MAKES

FIRST AND

BREAKS LAST

All Posi-LokSystems are

UL ListedPatent

#4,767,347

ULFileNumberE67181

CSA FileNumber

LR13963-48

NEC is aregistered

trademark ofthe National

FireAssociation

Inc.

2

Meet NEC® StandardsThe Posi·Lok™ PowerDistribution System from CooperInterconnect brings a new level ofsafety to electrical powerapplications.

Now there's no need to haularound python-sized, multi­conductor cables. Posi-LokPower Distribution Systems letyou use lighter, single conductorcables rated at higher amperages.

Designed to meet Article 520-53 Section K and Article 530-22 Section A(NEG) standards, Posi-Lok's built-in safety feafures require the user toconnect or disconnect each plug in sequence. Protective covers cannot beraised until the preceding plug is locked into position. The disconnectsequence is reversed.

The same plugs that connect to panels also connect to each other so that youcan use long runs of cable. Polarity is assured because each plug is uniquelykeyed and color-coded for easy, positive connecting.

Posi-Lok plugs feature recessed electrical contacts that are protected byshatter-resistant synthetic rubber insulators and impact-resistant moldedsleeves.

Posi-Lok is part of the Cam-Lok® family of connectors

Page 3: Posi-LokPlu s and Panels · Posi-LokPlu s and Panels In-lineplugs make ... keyed and color-codedfor easy, ... Description Position pMart,eNcomPlete OMa,'e Cp°rtn'Nact Polarizing

l;=;=Posi-Lok PluTypical Uses

and Panels

3

PORTABLE POWER

MEDICAL

ENTERTAINMENT

Posi-Lok Systems are used in dozens of demanding applications, bothindoors and out. They provide the means for hurried personnel to quickly

connect and disconnect powersystems safely at professionalperformances. And they can beused for connecting standby powergenerators and load testingequipment in hospitals and in heavyindustrial environments.

Page 4: Posi-LokPlu s and Panels · Posi-LokPlu s and Panels In-lineplugs make ... keyed and color-codedfor easy, ... Description Position pMart,eNcomPlete OMa,'e Cp°rtn'Nact Polarizing

Posi-Lok Plu s and Panels

THERE IS A

POSI-LOK

SYSTEM FOR

EVERY

APPLICATION

SpecificationsCooper Interconnect offers UL listed andGSA certified Posi-Lok Systems in the sizesyou need most...200, 315, and 400amperes. You can order optional 6-positionpanels which include a double neutralposition to solve harmonic problems in yourdistribution system.

These systems were designed with the userin mind. The 315 and 400 amp panels canbe installed into a standard 19-inch rack.The 200 amp panel requires as small as a13.5-inch wide space. See pages 8 and 18for mounting dimensions.

. - .- \./

- --

Consult the factory for additional polarizing configurations.

4

The Gam-Lok® double cam principleprovides a positive vibration-proofconnection. Just 1/3 of a turn assures ahigh pressure contact with minimumelectrical resistance. The self-wiping actionmaintains clean contact surfaces. Thepatented design is self-compensating forwear.

Posi-Lok panels are "Lockout-Tagout"compatible.

Lock the grounding cover and the entirepanel system cannot be used.

Lock the fourth cover when singlephase, 3-wire system is desired.

Lock fifth cover when 4-wire system isdesired.

Page 5: Posi-LokPlu s and Panels · Posi-LokPlu s and Panels In-lineplugs make ... keyed and color-codedfor easy, ... Description Position pMart,eNcomPlete OMa,'e Cp°rtn'Nact Polarizing

Posi-Lo Plu and PanelsSpecial Features E0200 SeriesTermination barrel (set screw versionshown). Crimp style also available

O-Ring

Contact retaining nut E200 SERIES

PLUG

CUTAWAY

Built-in strain relief reducescable strand breakage

Cable jacketretaining wire

Recessedcontacts

Impact-resistantpolarizing sleeve

More than 20 years of field testing has proventhat the unique synthetic rubber, taperedinsulator allows maximum flexing withminimum breakage. There are no metalclamps or grommets to cause cable failure.

Series Number Receptllcles Amp MaxImum Contllct Maximum Cable TempPer Panel Rating Voltage Material Cable Size Tennination Rating

E0200 3.4,5,or6 200 600 ACIDC Sliver Plated(Ul) Copper

600AC(GSA)

2JO Cnmp and set t 050(:

"".w

The E0200 Series male connector is the output side.

NOTE: For 400 amps, the following type cables may be used:UL Type SC, CSA Type PPC 1050C or Type W 90°C.

POSI-LoK

CONTACTS

FEATURE

EXCLUSIVE

CAM-LOK

ACTION

5

Page 6: Posi-LokPlu s and Panels · Posi-LokPlu s and Panels In-lineplugs make ... keyed and color-codedfor easy, ... Description Position pMart,eNcomPlete OMa,'e Cp°rtn'Nact Polarizing

Posi-Lok Plu s and PanelE0200 Series

Receptacles Per Panel Female Panels Cover Color Code

Female Panel Part Numbers3, 4, 5 or 6 WireSystem, ratedup to 200 amps,continuous, 600volts, 105°C

34

4

4

55

E0200-1685E02O().1686·NN

E0200-1696

E0200-1892-NN

E0200-1687

E0200-1890

E0200-1685

GR,WH,BK

GR. BK. AD, SU

GR, WH, BK, AD

GR, BAN, ORG, VEL

GR, WH, BK. AD, SU

GA, WH, BAN, ORG, VEL

GA, WH, WH, BK, AD, euRD :: Red eu = BlueNN = Panel without Neutral

GR = Green WH = White BK :: BlackBRN = Brown ORG = Orange VEL = YellowOther Color Codes available; consult factory.Add -lS· suffix to end of part number to order panels with a limit switch.Available on lasl position only. Example: E0200-1687LS.limit switch ratings are SA, 250VAC.Plugs must be ordered separately. see below.

Male Plugs

MalePlugs

Assembledlength is 8 y.-

Male InsulatorlDescription Position pMart,eNcomPlete OMa,'e Cp°rtn'Nact Polarizing Shell

a o. n y a o. Part No.Crimp

'2·210

Green

WhiteBlack

E02QO-141

E0200-142E0200-143

A201293·5

A201293-5A201293-5

A201315·3

A201315-2A201315-1

E0200·144 A201293·5 A20131S-5

E0200-145 A201293-S A201315-4

E0200·147 A201293-5 A201315-9

E0200-148 A201293-5 A201315-10E0200-149 A201293-5 A20131S-8

E0200-181 A201293-1 A201315-3

E0200-182 A201293-1 A201315-2E02OO-183 A201293-1 A201315-1

E0200-184 A201293-1 A201315-S

E0200-185 A201293·1 A201315-4

E0200-199 A201293-1 A201315-9

E0200-195 A201293·1 A201315-10E0200-192 A201293·1 A201315-8

Red

Blue

Brown

OrangeYellow

#2=190 AMPS

#1=200 AMPS

110=200 AMPS

210=200 AMPS

'2=190 AMPS

"=200 AMPS

110=200 AMPS

210=200 AMPS

Double Set Screw

12-2/0

Green

WhiteBlack

RedBlue

",own

o<angeYellow

NOTES: Ampacity is based on cable size or contact rating, whichever is less.E0200 Series male contacts (plugs and panels) have Ul approved insulated ends.E0200 Series have silver prated copper contacts.Panel does not include enclosure or breakers. Posi-lok System must be installed per local and nationalstandards.Panel receptacles have lock washers, llat washers and jam nuts included .•

Page 7: Posi-LokPlu s and Panels · Posi-LokPlu s and Panels In-lineplugs make ... keyed and color-codedfor easy, ... Description Position pMart,eNcomPlete OMa,'e Cp°rtn'Nact Polarizing

Posi-Lok Plu s and PanelsE0200 Series

Male Panel Part Numbers

Receptacles Per Panel Male Panels Cover Color Code3

4

4

4

5

5

6

E02OO-1660

E0200-1661-NN

E0200-1672

E0200-1893-NN

E0200-1662

E0200-1891

E0200-1860

GR, WH,BK

GR, BK, RD, BUGR, WH, BK, RD

GR, BAN, ORG, YEL

GR, WH, BK, RD, auGR, WH, BRN, ORG, VEL

GR. WH, WH, BK, AD, auAD = Red au = BlueNN = Panel without Neutral

GR = Green WH = White BK :: BlackBAN = Brown ORG = Orange YEL = YellowOther Color Codes available; consult factory.Add "LS" suffix to end of part number to order panels with a limit switch.Available on last position only. Example: E0200-1662lS.Limit switch ratings are SA, 250VAC.Plugs must be ordered separately. see below.

iFemalePlugs

Female Plugs

Male Insulator!Description Position pMartleNcomPlete oMalle Cp°rtn'N8ct Polarizing Shell

a o. ny a o. Part No.

Crimp Green E0200-241 A201292-5 A201315-27

#2-2/0 White E0200·242 A201292-5 A201315-26Black E0200-243 A201293-5 A201315-25

#2=190AMPS Red E0200-244 A201292-5 A201315-29

#1=200 AMPS Blue E0200-245 A201292-5 A201315-28

110=200 AMPS Brown E0200-247 A201292-5 A201315-33

210=200 AMPS Orange E0200-248 A201292-5 A201315-34Yellow E0200-249 A201292-5 A201315-32

Double Set Screw Green E0200-281 A201292-1 A201315-27

#2-2/0 White E0200-282 A201292-1 A201315-26Black E0200-283 A201292-1 A201315-25

#2=190AMPS Red E0200-284 A201292-1 A201315-29

#1=200AMPS Blue E0200-285 A201292-1 A201315-28

1!O=200AMPS Brown E0200-288 A201292-1 A201315-33

210=200 AMPS Orange E0200-289 A201292-1 A201315-34Yellow E0200-286 A201292-1 A201315-32

NOTES: Ampacity is based on cable size or contact rating, whichever is less.E0200 Series male contacts (plugs and panels) have UL approved insulated ends.E0200 Series have silver plated copper contacts.Panel does not include enclosure or breakers. Posi-Lok System must be installed per local and nationalstandards.Panel receptacles have lock washers, Ilat washers and jam nuts included.

Assembledlength is 8 l'.

7

Page 8: Posi-LokPlu s and Panels · Posi-LokPlu s and Panels In-lineplugs make ... keyed and color-codedfor easy, ... Description Position pMart,eNcomPlete OMa,'e Cp°rtn'Nact Polarizing

Posi-Lok Plu s aRd PanelsPanel Dimensions E0200

r25 x .38 Slot r- TYP._

4 Plc's. U

l:~r'.,-,

l ~i2.'r - - - - - -,,- 12.05 Inside Cut QuI For "6~Pllnel

13.41 0ve<811 Length lot6 Posibon Panel

'"'"""'~- ~53.1.\_ I/~"""Ava~aDle

2.68_ lasl .

"'"•

1.2S d:t

,.. '\ 2.

'- ",.,

~J1 00 .333.2~__4.53

J

'."

,

1.25 r-

~".653.'1_

-

,..Jf"32J3.26_

U,__--l

8

'"r .25 X .38 Slot r-TYP. -."". U6

'li2.k l

TCuljo..t 22

- - - - -,,- 10.07 InSIde Cut Out For 1--."5 Positioo Panel

11.43 0Ye<a1l Length fo(

5 Position Panel

8

":'\ ~; - ,

,~ n ;----t r---I IJ-I '~['(T "- - -

"- 8 09 _ CuI OUI For 1--"• Pos&lIon p_

;.5 a-.. L«IgIIIlot'_P-

2'5 X.38.~

Allmeasurementsare in inches

":\ c- -'"

2.1.c b 1 L~,~

'IT,

- - -."- S 11 _ e..tOuc FOf 1--"- 3_P_ -

7.7~ lorqlllot,--8 .,.

CODF ER Interoomect

Page 9: Posi-LokPlu s and Panels · Posi-LokPlu s and Panels In-lineplugs make ... keyed and color-codedfor easy, ... Description Position pMart,eNcomPlete OMa,'e Cp°rtn'Nact Polarizing

Posi-Lok Plu and PanelsE0315/E0400 Special Features

Cable jacketretaining wire

Impact-resistantpolarizing sleeve

Recessed contacts E0315-E0400SERIES PLUG

CUTAWAY

ASSEMBLED

LENGTH IS

71'-

Built-in strain relief reducescable strand breakage

Termination barrel (Set Screw Versionshown). Crimp style also available

More than 20 years of field lesting has proventhat the unique synthetic rubber, taperedinsulator allows maximum llexing withminimum breakage. There are no metalclamps or grommets to cause cable failure.

E0315·E0400 Contact

POSI-LoK

CONTACTS

FEATURE

EXCLUSIVE

CAM-LOK

ACTION

E0315

Sertes Rocoptacles Amp Cable Cable Contoct Plug Plug Rooeptacla RoceptaclePolerizlng Insulator Houllng Cove.

Number Per Pinel Flllllng Pntnmelera TermlNltlon Malerlal M.tlrl.1 Matarl.l Mate.btl Matcrtlll

E<MOO 3,.5 or6

9

SIMPLE DESIGN

ALLOWS FOR

EASY ASSEMBLY

-­"""""""-

---_'PO"TPE Co8lecl3ltS"""- "'""""""""

..-COOPHt .uwrl8d

" ....

'"3,.5 orllE0315

E0400

Page 10: Posi-LokPlu s and Panels · Posi-LokPlu s and Panels In-lineplugs make ... keyed and color-codedfor easy, ... Description Position pMart,eNcomPlete OMa,'e Cp°rtn'Nact Polarizing

Posi-Lok Plu s and Panels[0315 Series

Female Panel Part Numbers

Receptacles Per Panel Female Panels Cover Color Code

3, 4, 5 or 6 WireSystem, ratedup to 315 amps,continuous, 600valls, 1050e

3

4

4

4

5

5

6

E0315-1685

E0315-1686-NN

E0315-1696

E0315·1863-NN

E0315-1687

E0315·1702

E0315-1885

GA, WH, BK

GA, BK, AD, auGR, WH, BK, RD

GA, BRN, OAG, VEL

GR, WHo BK, RD. auGA, WH, BAN, ORG, VEL

GR, WH, WH, BK, AD, au

'0

GR = Green WH '" While BK =Black RD = Red au = BlueBRN '" Brown ORG = Orange YEL"" Yellow NN '" Panel without NeutralOther Color Codes available; consultlactory.Add "LS~ suffix to end of part number to order panels with a limit switch.Available on last position only. Example: E0315-1687LS.Limit switch ratings are SA, 250VAC.Plugs must be ordered separately. See below.

Page 11: Posi-LokPlu s and Panels · Posi-LokPlu s and Panels In-lineplugs make ... keyed and color-codedfor easy, ... Description Position pMart,eNcomPlete OMa,'e Cp°rtn'Nact Polarizing

Po i-Lo[0315 Series

Plu and Panels

MALE PLUGS

ASSEMBLED

LENGTH IS7 %~

Male Plugs

Male PolanzlOQD. P t Male Complete Gonia t 0 Iy Male Insulator Sh"

escnplOn OSllQn P rtN c n P rtN ea 0 Part No a 0 Part No

Crwnp 12-11 G"en E0315-121 A201271-4 3336200-1 A201279-11wt>'e E0315-122 A201271-4 3336200-2 A201279-12

12 -l90AMPS iliad< E0315-123 A201271-4 :J3362OO.3 A201279-13

'l·22QAMPS Red E0315-124 A201271-4 3336200-<1 A201279-14

"'... E0315-125 A201271-4 3336200-, A201279-15

"'~ E0315-126 A201271-4 33362O<><i A201279-23

0""... EOOlS-12l A201271-4 3336200-7 A2Q1279-24Yonow E0315-128 A201271-4 3336200-8 A201279-25

Cnmp lJO-2JO G,... E0315-141 A201271-5 3336200-' A20'279-8White E0315-142 A201271-5 3338200-2 A201279-7iliad< E0315-143 A201271-S 3336200-3 A201279-8

l,u - 260 AMPS Red E0315-144 A201271-S 3338200-4 A201279-9

2JO·300AMPS "'... E0315-145 A201271·5 3338200-' A201279-10

""ow. E0315-146 A201271-5 3338200-8 A201279·26

O"""e E0315-147 A201271-5 3338200-7 A201279-27Yellow E0315-148 A201271-5 3338200-8 A201279-28

Cnmp 3/0-410 G,... E0315-161 A201271-6 3338200-' A201279-1While E0315-162 A201271-6 3336200-10 A201279-2

3IO-315AMP$ Black E0315-163 A201271-6 3336200-1\ A201279-3

410· 315AMPS Red EQ315·164 A201271-6 3336200·12 A201279-4Blue E0315-165 A201271-6 3336200-13 A201279-5Brown E0315-166 A201271-6 3336200-14 A201279-29Orange E0315·167 A201271·6 3336200·15 A201279·3QYellow E0315·168 A201271-6 3336200-16 A201279-2O

Double set SCrew Green E0315·171 A201283-2 3336200-1 A201279-6

12-210 White E0315·172 A201283-2 3336200-2 A20t279-7Black E0315·173 A201283·2 3336200·3 A201279·8

12. - 190 AMPS Red E0315·174 A201283-2 3336200·4 A201279-9

11 - 220 AMPS Blue E0315-175 A201283-2 3336200-5 A201279-10

1,u-260AMPS Brown E0315·176 A201283-2 3338200-6 A201279-26

210· 300 AMPS 00.... E0315-177 A2Q1283·2 3336200·7 A2Q1279·27Yetlow E0315-178 A201283-2 3338200-8 A201279-28

Double set SCrew Green E0315-181 A201283-4 3338200-' A201279-1

:W-"" WMe E0315-182 A201283-4 3336200-.0 A201279·2

.'001< E0315-183 A2Q1283·4 3336200·11 A201279·3

3JO. 315 AMPS Aed E0315-164 A201263·4 3336200·12 A201279-4

4JO - 315 AMPS Blue E0315-185 A201283-4 3336200-'3 A201279-58<ow. E0315-196 A201283-4 3336200- •• A201279·29Ooe... E0315-195 A20'283-4 3336200-" A201279-30Yellow E0315-192 A201283-4 3336200-1' A201279-20

NOTES. AmpaaIy IS based on cable SIZe or contact rating. whichever IS lessE0315 5eoes nas brass contactsPanel does r'lOIlI'lClucle enclosure or breakers Posrlok System must be IfISlaDed per local and natJonal standards.Panel receptaCles have lock washers. flat washers and JCIffi nuts 1nCIucIed.

11..-CO'lI & InlerwIl8d

Page 12: Posi-LokPlu s and Panels · Posi-LokPlu s and Panels In-lineplugs make ... keyed and color-codedfor easy, ... Description Position pMart,eNcomPlete OMa,'e Cp°rtn'Nact Polarizing

~Po i-Lok Plu s and PanelsE0315 Series

Male Panel Part Numbers

Receptacles Per Panel Male Panels Cover Color Code

3, 4, 5 or 6 WireSystem, ratedup to 315 amps,continuous, 600volts, 105'C

3

4

4

4

5

5

E0315-1660

E0315-1661-NN

E0315-1672

E0315-1862-NN

E0315-1662

E0315-1703

E0315-1860

GR.WH, BK

GA, BK, RD, auGR, WH, BK, AD

GR, BAN, DAG, VEL

GR, WH, BK. AD, auGR, WH, BAN, CRG, VEL

GA, WH, WH, BK. RD, au

12

GR :: Green WH = White BK = Black. AD :: Red au = BlueBRN = Brown GAG = Orange VEL:: Yellow NN '" Panel without NeutralOther Color Codes available; consult factory.Add "'lS· suffix 10 end of part number to order panels with a limit switch.Available on last position only. Example: E0315-1662lS.limit switch ratings are SA, 2SOVAC.Plugs must be ordered separately. See below.

Page 13: Posi-LokPlu s and Panels · Posi-LokPlu s and Panels In-lineplugs make ... keyed and color-codedfor easy, ... Description Position pMart,eNcomPlete OMa,'e Cp°rtn'Nact Polarizing

Posi-Lok Plu[0315 Series

s and Panels

FEMALE PLUGS

ASSEMBLED

LENGTH IS7 X-

Female Plugs

Male Com lete Male Male Insulator PolarizingDeSCription POSlliOn P rt N P Contact Only P rt N Shell

a 0 Part No a 0 Part No

Crimp '2-1' Green E0315-221 A200035-66 3336199-' A201280-12While E0315-222 A2OOO35-66 3336199-2 A201280-13

12-190AMPS Black E031S-223 A2OOO35-66 3336199-3 A2Q1280·14

11 - 220 AMPS Rod E0315-224 A2OOO35-66 3336199-4 A201280-15Blue E0315-225 A200035-66 3336199-5 A201280-16Brown E0315-226 A200035-66 3336199·6 A201280-28Orange E0315-227 A2OOO35-66 3336199-7 A201280-29Yellow E0315-228 A2OOO35-66 3336199-8 A201280·25

Cnmp 1/0-210 Green E0315-241 A200035-67 3336199-1 A201260-7White E0315-242 A200035-67 3336199-2 A201280-8Black E0315-243 A200035·67 3336199-3 A201280-9

I/O· 260 AMPS Rod E0315·244 A200035-67 3336199-4 A201280-10

210· 300 AMPS Blue E0315·245 A200035·67 3336199-5 A201280-11Brown E0315-246 A200035·67 3336199-6 A2Q1280·30Orange E0315-247 A200035·67 3336199-7 A201280-31Yellow E0315-248 A200035·67 3336199-8 A201280-23

Crimp 3/0-4/0 Green E0315-261 A200035-68 3336199-9 A201280-1White E0315·262 A200035·68 3336199-10 A201280-2

3JO..315 AMPS Black E0315-263 A200035-68 3336199-11 A201280-3

4IO-315AMPS Rod E0315-264 A200035-68 3336199-12 A201280-4BJoo E0315-265 A200035-68 3336199-13 A201280-5Brown E0315-2S6 A200035-68 3336199-14 A201280-32Orange E0315-267 A200035-68 3336199-15 A201280-33Yellow E0315·268 A200035-68 3336199-16 A201280-21

Double set SCrew Green E0315-251 A201284-2 3336199-1 A201280-7

112-210 While E0315-252 A201284-2 3336199-2 A201280-8Black E0315-253 A201284·2 3336199-3 A201280-9

12 -190AMPS R'" E0315-254 A201284-2 3336199-4 A201280-10

111- 220 AMPS Blue E0315-255 A201284-2 3336199-5 A201280-11

1,u - 260 AMPS Brown E0315-256 A201284-2 3336199-6 A201280-30

210 - 300 AMPS OrallQe E0315-257 A201284-2 3336199-7 A201280-31Yellow E0315·258 A201284-2 3336199-8 A201280-23

Double set SCrew Green E0315-261 A2OO641-1 3336199-9 A201280-1

3/0-4/0 White E0315-262 A2OO641-1 3336199-10 A201280-2Black E0315-283 A2OO641-1 3336199-11 A201280·3

310 - 315AMPS Rod E0315-284 A2OO641-1 3336199-12 A201260-4

410 - 315AMPS Blue E0315-265 A200641-1 3336199-13 A201280-5Brown E0315·296 A200641-1 3336199-14 A201260·32Orange E0315-295 A200641-1 3336199-15 A201260-33Yellow E0315-292 A200641-1 3336199-16 A201280-21

NOTES: Ampacity IS base<:! on cable si~e or contact rating, whichever is less.E0315 series has brass conlacts.Panel does not include enclosure or breakers. Posi-Lok System must be installed per local and national standards.Panel receptacles have lock washers. flat washers and jam nuts include<:!.

13

--COOPBllnterromecl

Page 14: Posi-LokPlu s and Panels · Posi-LokPlu s and Panels In-lineplugs make ... keyed and color-codedfor easy, ... Description Position pMart,eNcomPlete OMa,'e Cp°rtn'Nact Polarizing

=Posi·Lok Plu s and PanelsE0400 Series

Female Panel Part Numbers

Receptacles Per Panel Female Panels Cover Color Code

3, 4, 5 or 6 WireSystem, ratedup to 400 amps,continuous, 600volts, 105'e

3

4

4

4

5

5

6

E0400-1685

E0400-1686-NN

E0400-1696

E0400·1883·NN

E0400-1687

E0400-1702

E0400-1885

GR, WH,BK

GR, BK, AD, auGR, WH, BK, RD

GR, BAN, QRG, VEL

GR, WH, BK, RD, auGR, WH, BAN, QRG, VEL

GA, WH, WH, BK, RD, au

14

GR = Green WH = While BK = Black RD = Red au = BlueBAN = Brown QAG = Orange YEL", Yellow NN :: Panel without NeutralOther Color Codes available; consult factory.Add "LS" suffix to end or part number to order panels with a limit switch.Available on last position only. Example: E040Q·1687LS.limit switch ratings are SA. 250VAC.Plugs must be ordered separately. see below.

Page 15: Posi-LokPlu s and Panels · Posi-LokPlu s and Panels In-lineplugs make ... keyed and color-codedfor easy, ... Description Position pMart,eNcomPlete OMa,'e Cp°rtn'Nact Polarizing

Posi-Lok Plu[0400 Series

s and Panel

.

MALE PLUGS

ASSEMBLED

LENGTH IS7 y..

Male Plugs

Male POlanzlngMale Complete Male Insulator

Descnpllon Position P rt N Contact Only P rt N Shella 0 Part No a 0 Part No

Crimp Green E04QO.141 A201271-2 3336200-1 A201263-6

1}()·2JO While E0400-142 A201271-2 3336200-2 A201263-7Black E04Q().143 A2Q1271·2 3336200-3 A2Q1263-8

ll'O-260AMPS Rod E0400-144 A201271-2 3336200-4 A2Q1263·9

210 - 300 AMPS Blue E0400-145 A201271-2 3336200-' A201263-10",ow. E0400-146 A20127'-2 3336200<> A201263-29

0"""" E0400-147 A201271-2 3336200-7 A201263-JOV"1ow E0400-148 A201271-2 3336200<> A201263-31

Cnmp G,..., E0400-161 A201271-1 3336200-" A201263-1

310-4" WM. E0400-162 A20127H 3336200-10 A201263-2Blad< E0400-163 A2Q1271·1 3336200-11 A201253-3

3A:I. 350 AMPS Rod E0400-164 A201271-' 3336200-12 A201203-4

oW-400AMPS .... E0400-165 A201271-1 3336200-13 A201253-S

"'~ E0400-166 A201271-' 3336200-1. A201263-26

0".... E0400-167 A201271-' 3336200-1' A201263-23V_ E0400-168 A201271-1 3336200-16 A201263-25

Double set Screw Green E0400-151 A201283-3 3336200-1 A201263-6n_", White E0400-152 A201283-3 3336200-2 A201263-7

",,,ok E04O().l53 A201263-3 3336200-3 A201263-8

12-190AMPS Rod E0400-154 A201283-3 3336200-' A201263-9,,-220AMPS Blue E0400-155 A201283-3 3336200-' A201263-10

11O-260AMPS Brown E0400-156 A2Q1283·3 3336200-6 A2Q1263·29210· 300 AMPS Orange E0400-157 A201283-3 3336200-7 A201263-30

Yellow E0400-158 A201283-3 3336200-8 A201253-31

Double set SCrew Green E0400-181 A201283-1 3336200-9 A201263-1

3IC>4<l White E0400-182 A2Q1263·1 3336200-10 A2Q1263·2.,"" E0400-163 A201263-1 3336200-11 A201263-3

310- 350 AMPS Rod E0400-184 A201283-1 3336200·12 A2Q1263·4

410· 400 AMPS "'" E0400-185 A201283-1 3336200-13 A201263-5&OW. E0400-199 A2Q1283·1 3336200-1. A201263·26

""... E0400-195 A201283-1 3336200-1' A201263-23V"1ow E0400-192 A201283-1 3336200-16 A201263·25

NOTES Ampacrty is based on cable size or contact raltng, whIChever is lessE0315 senes has brass contacts.Panel does not include enclosure or breakers Posi-Lok System must be installed per local and nahonaJ standardsPanel receptacles have lock washers. flat washers and jam nuts included.

,,-COOPER IntelCOl.lElCt

15

Page 16: Posi-LokPlu s and Panels · Posi-LokPlu s and Panels In-lineplugs make ... keyed and color-codedfor easy, ... Description Position pMart,eNcomPlete OMa,'e Cp°rtn'Nact Polarizing

~Po i-Lok Plu s and Panels[0400 Series

Male Panel Part Numbers

Receptacles Per Panel Male Panels Cover Color Code

G, 4, 5 or 6 WireSystem, ratedup to 400 amps,continuous, 600volts, 105'e

3

4

4

4

5

5

6

E0400-1660

E0400-1661-NN

E0400-1572

E0400-1862-NN

E0400·1662

E0400-1703

E0400-1860

GA, WH, BK

GR, BK, RD, auGA, WH, BK, RD

GA, BAN, QRG, YEL

GA, WH, BK, RD, auGR, WH, BAN, GRG, YEL

GR, WH, WH, BK, AD, au

,.

GA = Green WH = White BK = Black AD = Red au = BlueBAN = Brown GAG = Orange YEL = Yellow NN = Panel without NeutralOther Color Codes available; consult factory.Add "LS" suffix 10 end of part number 10 order panels with a limit switch.Available on last position only. Example: E0400-1662LS.Limit switch ratings are SA, 250VAC.Plugs must be ordered separately. See below.

Page 17: Posi-LokPlu s and Panels · Posi-LokPlu s and Panels In-lineplugs make ... keyed and color-codedfor easy, ... Description Position pMart,eNcomPlete OMa,'e Cp°rtn'Nact Polarizing

Posi-Lok Plu[0400 Series

s and Panels

FEMALE PLUGS

ASSEMBLED

LENGTH IS7 Yo.

Female Plugs

Male Com lete Male Male Insulator PolanzlngDescnptlon POSItIOn Part No P Contact Only Part No Shell

Part No. Part NoCnmp Green E0400-241 A201272-4 3336199-1 A201262-61/0-210 White E0400·242 A201272-4 3336199-2 A201262-7

Black E0400-243 A201272-4 3336199-3 A2012£2·8

1/0 . 260 AMPS Rod E0400-244 A201272-4 3336199-4 A201262·92JO·300AMPS Blue E0400-245 A201272-4 3336199-5 A2Q1262·10

Brown E0400-246 A201272-4 3336199-6 A201262-27Orange E04OO-247 A201272-4 3336199·7 A201262-28'(allow E04OO-248 A201272-4 3336199-8 A201262-29

Crimp Green E04OO·261 A2Q1272·2 3336199-9 A201262-'3/0-4/1) White E04OO-262 A201272·2 3336199-10 A201262-2

Black E0400-263 A201272·2 3336199-11 A201262-3

3/0 - 350 AMPS Roo E0400-264 A201272·2 3336199-12 A201262-4

4/0 - 400 AMPS Blue E0400-265 A201272·2 3336199-13 A201262-SBrown E0400·266 A201272-2 3336199-14 A201262-26Orange E04DO-267 A201272-2 3336199-15 A201262-23Yellow E04DO-268 A201272-2 3336199-16 A201262-25

Double Set Screw Green E04oo-251 A201284-3 3336199-1 A201262-6

12-210 White E04oo·252 A201284-3 3336199-2 A201262-7Black E04oo-253 A201284-3 3336199-3 A201262-8

12 - 190 AMPS Rod E04oo-254 A201284-3 3336199-4 A201262-9

11 - 220 AMPS Blue E04oo-255 A201284-3 3336199-5 A201262-10

110 - 260 AMPS Brown E04oo-256 A201284-3 3336199-6 A201262-27

210 - 300 AMPS Orange E04OO-257 A201284-3 3336199-7 A201262-28Yellow E04OO-258 A201284-3 3336199-8 A201262-29

Double Set SCrew Green E04OO·281 A201284-1 3336199-9 A201262-1

3/0-410 White E04OO-282 A201284-1 3336199·10 A201262-2Black E04OO-283 A201284-1 3336199-11 A201262-3

3/0 - 350 AMPS Roo E04OO-284 A201284-1 3336199-12 A201262-4

4/0 - 400 AMPS Blue E04oo-285 A201284-1 3336199-13 A201262-5Brown E04oo-299 A201284-1 3336199-14 A201262-26Orange E04oo-295 A201284-1 3336199-15 A201262-23Yellow E04OO-292 A201284-1 3336199-16 A201262-25

NOTES: Ampaclty is based on cable size or contact rating. whichever is less.E0315 Series has brass contacts.Panel does not include erlClosure or breakers. Posi-Lok System must be installed per local and national standards.Panel receptacles have lock washers, tlat washers and jam nuts included.

17

Page 18: Posi-LokPlu s and Panels · Posi-LokPlu s and Panels In-lineplugs make ... keyed and color-codedfor easy, ... Description Position pMart,eNcomPlete OMa,'e Cp°rtn'Nact Polarizing

~Posi·Lok Plu s and PanelsPanel Dimensions E0315/E0400

,-------:,-------- 18.12 -----,

r----'----- 1900 --------,

112·13THREAD

COMNONC

LIMITSWITCH(TYP. ALLPOSITIONS)

4.06 TOSTUD SHOULDER

4.00

~"35~ .62

LIMIT SWITCH

3.40TYPICAL

OPTIO AL LIMITSWITCH POSITIONS

0.344 PLCS.

44

62

-13READ

35

oUlDER

400,-. '-104_ to-

L I '"r •r TH

1.

~ 4.06 TSTUD SHO

4

1.48

4.00

2.70 L3.40

TYPICAL

--­._---~-

0344 PLCS.

,- 21.53 --1

,----,-----2240 --,

18

ttl'COOPER Interconnect

Page 19: Posi-LokPlu s and Panels · Posi-LokPlu s and Panels In-lineplugs make ... keyed and color-codedfor easy, ... Description Position pMart,eNcomPlete OMa,'e Cp°rtn'Nact Polarizing

s and PanelsPosi-Lok PluParts, Tools and Accessories

Part Number Description ASSEMBLY

TOOLS AND

ACCESSORIESE0315 and E0400 Lektralink Assembly Tool.

Tool for removing E0315 and E0400 contacts frominsulators.

Cable Cutler - #2 - 4/0 Cable.

Insulator holding bracket.

Assembly tool for 200A plugs.

COM-A-LONG for pullingmale contact in E0315 andE0400 Series.

COM-A-LONG for pullingfemale contact in E0315and E0400 Series.

2 oz. tube silicon greasefor lubricating mating endof synthetic rubberinsulators.

A200020-4

A40000l

A100632

Al01208

A100072201310

A201303A20002O-3

Replacement Parts

E0315 and E0400 Series Crimping Nest and Presses'

;:~~:~~~ Set Screw Copper Shim Pressure Pad RetaIning Wire

100573-1

100573-1

100573-1

101214

101214

100400-5

100400-5

100400-8

Cap for male E0315 or E0400

Cap for female E0315 or E0400

Cap for male E0200

Cap for female E0200

100012-33

100012-18

100012-18

E0200

E031S

E0400

Al00601-17

Al006Q2·17

A201318-1

A201319-1

Part No. Description

Protective Plug Caps

C bl S· Crimping Nests Crimping Pressesa e Ize Part No. (Includes Crimp Nest)

12-11

111)-210

3KJ

4/0

100514-3

100514-4

100514-5

100514-6

A2OO914·3

A2OO914-4

A2OO914-5

A2OO914-6,COG &ItUOOIlltid

"Refer to instructionsheets for E0200crimping information

19

Page 20: Posi-LokPlu s and Panels · Posi-LokPlu s and Panels In-lineplugs make ... keyed and color-codedfor easy, ... Description Position pMart,eNcomPlete OMa,'e Cp°rtn'Nact Polarizing

...P_o~i-_Liiio....P_I_u s and Panel

til'COOPER Interconnect

Distributed by:

For more information, contact an authorized Cooper Interconnect Distributor, Sales Office orCustomer Service Department:

In the U.S.4758 Washington StreetLaGrange, NC 28551P: 252-566-3014F: 252-566-9337W: www.cooperinterconnect.com

In CanadaToll Free: 800-265-0502

CI-05-07Cooper Interconnect is Oil trademark of Cooper Industri••, Inc:.

mOO7 Cooper Industries, Inc;:.