Power Mod™
Commercial K-Base Meter Stacks (type WMK) are designed to meet the requirements of those utilities specifying bolt-in meter sockets for 400 and 600 Amp residential and commercial applications.
Features include:J QuickSystem™ featuresJ Exclusive Landis & Gyr K4, K5, & K7 meter socketsJ 1 position K4, K5, K7 modules with 400 & 600 Amp tenant mainsJ 2 position K7 module with 400 Amp tenant mainJ Space saving design
K-Base quick reference
J 400A & 600A 1-2 positions J 1200A Thru bus-ratingJ UL Standard # UL67J UL file # E27100J AIC Rating (25k)J Voltage - Single Phase 120/240V AC Max - Three In Single Phase Out 208Y/120V AC - Three Phase 240V AC MaxJ All swing latches and rivets are stainless steelJ NEMA 3R ratedJ G90 Galvanized SteelJ ANSI 61 Paint
www.sea.siemens.com/powermod
K-Base Meter Stacks
High qualityLandis & Gyr bolt on meter base
Connecting cross bus rated1200 Amps
External mainservice disconnectProvides safety with quick convenient access to disconnect made externally. Eliminates taking time to remove cover to disconnect
s | Power Mod™ with Quick System™
10-2 10-310-2 10-3
Power Mod: K-BaseFeatures
10-2 10-3
s | Power Mod™ with Quick System™
10-2 10-3
QuickConnect™ QuickConnect reduces bussing connections from many to one- ensuring a single reliable connection instead of multiple connections.
QuickTorque™ Eliminates the need for time consuming torque readings, this breakaway nut provides the correct indication of torque of the QuickConnect. When tightened, the outer head twists off at the proper torque for connection, leaving a single nut for future maintenance.
Siemensexclusivefeature
QuickRoll™ QuickRoll eliminates the typical metal brackets for mounting modules to the wall. Instead of metal scraping metal QuickRoll allows the module to glide down the mounting rail via a durable nylon wheel inside mounting bracket.
Siemensexclusivefeature
Mounting earPivot factory installed mounting ears to minimum or maximum position to provide additional stability when mounting equipment onto wall.
Siemensexclusivefeature
QuickBolt™QuickBolt eliminates the requirement to line up mechanical connections- instead bolts remain retracted until the openings lineup - allowing the bolts to protrude through automatically. Springs push the bolts through and provide positive pressure to keep boltsin place while wingnuts are attached and tightened.
Power Mod: K-BaseFeatures
s | Power Mod™ with Quick System™
10-4 10-510-4 10-5
Power Mod: K-BaseCatalog numbers
Commercial meter stacks: K-Base bolt-in, 25k AICc f
Catalog number
Meter positions per stack
Max. tenant breaker (Amps)
Breaker provisiond
Dimensions (inches)a
Phase
KOdwg.no.
Schematicsno.Height Width Depth
1-phase, 3-wire SN, incoming and outgoing, K4 K-Base bolt-in
WMK11400Rd 1 400 JXD62B400 Factory Inst. 54.00 19.25 10.00 — KB-1 S-1
WMK11600R 1 600 LXD62B600 Factory Inst. 54.00 19.25 10.00 — KB-1 S-1
3-phase, 4-wire SN, incoming and 1-phase, 3-wire SN outgoing, K5 K-Base bolt-inb f
WMK12400RJd 1 400 JXD62B400 Factory Inst. 54.00 19.25 10.00 AB KB-2 S-2
3-phase, 4-wire SN, incoming and outgoing, K7 K-Base bolt-ine
WMK13400RJd 1400
JXD63B400 Factory Inst.
54.00 19.25 10.00 — KB-2 S-3
WMK23400RJd 2 72.88 27.00 11.00 — KB-3 S-4
WMK13600RJ 1 600 LXD63B600 Factory Inst. 54.00 19.25 10.00 — KB-2 S-3
a Dimensions shown are representative of outside box dimensions and do not include allowances for mounting bumps, hubs, or hardware protrusions.b Not for use on 3-Phase 4-wire delta systemsc Max AIC determined by maximum AIC of tenant breakers when used in conjunction with a meter socket. Higher overall ratings may be achieved
through approved series rating combinationsd Alternate amperage breakers are available. Please see table below for suffix that needs to be added for ordering. Extended leadtime may apply. Contact
sales office for more details.e Rated for use with 240/120V Delta systems f Commerical Stacks are not field phaseable
AddSuffix
1 Meter Position Per Stack
Breaker Amperage
T1 200A
T2 250A
T3 300A
T4 350A
AddSuffix
2 Meter Positions Per Stack
Breaker Amperage
T5 200A/200A
T6 200A/250A
T7 200/300A
T8 200/350A
T9 200/400A
T10 250A/300A
T11 250A/350A
T12 250A/400A
T13 300A/300A
T14 300A/350A
T15 300A/400A
T16 350A/350A
T17 350A/400A
Alternate amperage breakers
10-4 10-5
s | Power Mod™ with Quick System™
10-4 10-5
Power Mod: K-BaseKnockout diagrams
KB-1
WMK11400RWMK11600R
KB-2
WMK12400RJWMK13400RJ
WMK13600RJ
Equip. Grd.
WMK11400R
A
B
N
BA
A
B
N
WMK11600R
Schematics
KB-3
WMK23400RJ
S-1
WMK11400R WMK11600R
Equip. Grd.
A
B
N
BA
A
B
N
CC
NEUTRAL(POTENTIAL JAW)
WMK12400RJ
WMK13400RJ
Equip. Grd.
A
B
N
CA
A
B
N
CC
B HIGH LEG FOR 3Ø, 4 WIRE DELTA SYSTEM
NEUTRAL(POTENTIAL JAW)
WMK13600RJ
EQUIPMENT GROUND
NEUTRALLUGS
ANB
ANB
B C
C C
A
B CA
HIGH LEG FOR 3Ø, 4 WIRE DELTA SYSTEM
HIGH LEG FOR 3Ø, 4 WIRE DELTA SYSTEM (ALL BRANCH POSITIONS)
NEUTRAL(POTENTIAL JAW)
WMK23400RJ
S-2
WMK12400RJ
WMK13400RJ
Equip. Grd.
A
B
N
CA
A
B
N
CC
B HIGH LEG FOR 3Ø, 4 WIRE DELTA SYSTEM
NEUTRAL(POTENTIAL JAW)
WMK13600RJ
EQUIPMENT GROUND
NEUTRALLUGS
ANB
ANB
B C
C C
A
B CA
HIGH LEG FOR 3Ø, 4 WIRE DELTA SYSTEM
HIGH LEG FOR 3Ø, 4 WIRE DELTA SYSTEM (ALL BRANCH POSITIONS)
NEUTRAL(POTENTIAL JAW)
WMK23400RJ
S-3
WMK13400RJ WMK13600RJ
EQUIPMENT GROUND
NEUTRALLUGS
ANB
ANB
B C
C C
A
B CA
HIGH LEG FOR 3Ø, 4 WIRE DELTA SYSTEM
HIGH LEG FOR 3Ø, 4 WIRE DELTA SYSTEM (ALL BRANCH POSITIONS)
NEUTRAL(POTENTIAL JAW)
WMK23400RJS-4
WMK23400RJ
Notes:
Notes:
Amperage
400
600
Cover
R = Ringless
BLANK = Ring Type
5th jaw
J = 5th jaw installed (7 jaws for 3-phase in/out)
BLANK = No 5th jaw
Positions
1
2
Phase
1 = Single phase
2 = 3-phase in/single out
3 = 3-phase
WMK
WMK = NEMA 3R K-Base
Catalog Number Logic Example
W M K 1 1 400 R J
Subject to change without prior notice Order No.: RPFL-CSKBS-0409Printed in USA © 2009 Siemens Energy & Automation, Inc.
Siemens Energy & Automation, Inc.Industry Sector3333 Old Milton ParkwayAlpharetta, GA 300051-800-964-4114
The information provided in this brochure contains merely general descriptions or characteristics of performance which in case of actual use do not always apply as described or which may change as a result of further development of the products. An obligation to provide the respective characteristics shall only exist if expressly agreed in the terms of contract.
All product designations may be trademarks or product names of Siemens AG or supplier companies whose use by third parties for their own purposes could violate the rights of the owners.
www.sea.siemens.com/powermod