Practical Test KFV2032

Embed Size (px)

DESCRIPTION

pneumatic test

Citation preview

Section A

CONFIDENTIAL

EFV 1072

Pneumatic And

Electropneumatic Tech.

Jan Jun 2011CONFIDENTIAL

EFV 1072

INSTITUT KEMAHIRAN MARASUNGAI PETANIKEDAH

PRACTICAL TEST 1JAN JUN 2011 SESSION

SUBJECT:EFV 1072 PNEUMATIC & ELECTROPNEUMATIC

TECHNOLOGY (PRACTICAL)DATE

:MAC 2010DURATION:3 HOURS

COURSE:SKEIDO NOT OPEN THIS QUESTION BOOKLET UNTIL YOU TOLD TO DO SOInstructions:

1. This question booklet consists of Two (2) tasks. Answer both tasks.2. Read the instruction carefully before you doing the practical.

3. Write your answer at answer sheet.

4. Inform the instructor when you are finishing the job.

Prepared by:

Checked by:

..

..

(PN.ROSNANI ALI)

(EN. AZHARI BIN AHMAD)

This booklet consists 6 printed pages including this page.TEST 1

COURSESKEITIME

TITLE

FUNCTIONAL TEST ON PNEUMATIC SYSTEM.

SUBJECTEFV 1072 PNEUMATIC & ELECTROPNEUMATIC TECHNOLOGY

SEMESTER/SESSION1/ JAN JUN 2011

STUDENT NAME

TASK 1 :

Figure 1

TOOLS/EQUIPMENT/MATERIALSNO

ITEMS

QUANTITY

1

Double acting cylinder

1

2

5/2 way double solenoid valve1

3

3/2 way push button spring return valve243/2 way roller lever spring return valve

1

5One way flow control valve1

6Quick exhaust valve17Two pressure valve

1

8Miscellaneous :

Air tube

As required

PROCEDURE

1. Construct the circuit in figure 1 on workstation.

2. Connect the air tubing and cable wire to the components according to the circuit diagram.

3. Observe the movement double acting cylinder when the push button is press according to the table 1.4. Describe the cylinder movement and draw the displacement step diagram.5. Show the circuit to the examiner to confirm the operation.

TASK 2 :PROCEDURE:1. Read the problem description given below.

2. List the appropriate components used.

3. Draw the pneumatic circuit diagram.

Problem description

With the help of the vertical switching point, soft cool (lignite) briquettes are to be fed to an upper or lower conveyor, according to selection.

The destination of the swiveling slide (upper or lower) is decided by means of a valve with selector switch. The upper motion of the double acting cylinder (1A) is take place in t1 = 3s; the downward motion in t2 = 2.5s. In the initial position, the cylinder assumes the retracted end position.

Task 1:1. Table 1

SW1

SW2

OUTPUT

CYLINDER MOTION

OFF

OFF

OFF

ON

ON

OFF

ON

ON

2. Describe the cylinder movement

3. Draw the displacement-step diagram

Task :

1. Components list:

_____________________________________

_____________________________________

_____________________________________

_____________________________________

_____________________________________

_____________________________________

_____________________________________

_____________________________________

2. Pneumatic circuit diagram.

SW1

SW2

LS

LS

LS

LS