15
17135 0970 C0.0 E. FOSTER M. SMAIL NO SCALE NOVEMBER 2, 2017 19TH & CHET ATKINS OFFICE BUILDING CREED INVESTMENTS COMPANY FOR 19TH COUNCIL DISTRICT, NASHVILLE, DAVIDON COUNTY, TENNESSEE SITE LAYOUT PLAN C1.0 COVER SHEET G:\17135-0970\1-CIVIL ENGINEERING\3-PLAN SHEETS\PRELIMINARY SP\0970 COVER.DWG PLOTTED BY EVAN FOSTER ON: 12/28/2017 9:02 AM LAST UPDATED BY EBF ON: 12/28/2017 9:00 AM JOB NO. WK. ORDER SCALE: DATE: DRAWN: REVISIONS DESIGNED: EXISTING CONDITIONS & DEMOLITION PLAN C0.2 SITE 19TH & CHET ATKINS OFFICE BUILDING PRELIMINARY SP LOCATION: 821, 823, 825, & 827 19TH AVE S, NASHVILLE, TN Know what's below. before you dig. Call METRO CASE # 2017SP-095-001 COVER SHEET C0.0 INDEX OF SHEETS OWNER/DEVELOPER DAVID CREED CREED INVESTMENTS CO. 144 2ND AVE N, SUITE 300 NASHVILLE, TN 37201 (615) 246-0222 [email protected] LANDSCAPE ARCHITECTURE RAGAN SMITH & ASSOCIATES, INC. 315 WOODLAND STREET NASHVILLE, TN 37206 (615) 244-8591 CIVIL BRAD SLAYDEN, PE RAGAN SMITH & ASSOCIATES, INC. 315 WOODLAND STREET NASHVILLE, TN 37206 (615) 244-8591 [email protected] ARCHITECTURE GRESHAM SMITH & PARTNERS 222 2ND AVE, SUITE 1400 NASHVILLE, TN 37201 (615) 770-8100 CONTACTS CIVIL PLANS SHEET DESCRIPTION PURPOSE NOTE The purpose of this SP is to rezone 0.76 acres to allow for the construction of a mid-rise office building (±255,000 gsf) EXISTING PROPERTY INFORMATION COUNCIL DISTRICT NUMBER: 19 DISTRICT COUNCIL MEMBER: FREDDIE O'CONNELL PROPERTY OWNER(1): 19TH AVE LAND PARTNERS, LLC 421 CHURCH STREET NASHVILLE, TN 37219 PROPERTY OWNER(2): VERGES-JAMES, LLC 823 19TH AVENUE SOUTH NASHVILLE, TN 37203 PARCELS & ACREAGE: (PARCELS 265, 266, 267, 268) 33,257 SF [0.76 AC] EX. BUILDING SF: 6,069 SF TOTAL (3 BUILDINGS) TAX MAP: 92-16 METRO GIS ID: 09216026500, 09216026600, 09216026700, 09216026800 STREET ADDRESS: 821, 823, 825, & 827 19TH AVE S NASHVILLE, TN 37203 ZONING: ORI-A/OV-UZO, OFFICE/RESIDENTIAL INTENSIVE ALTERNATIVE LAND USE: COMMERCIAL, OFFICE, PARKING LOT COMMUNITY PLAN: GREEN HILLS-MIDTOWN COMMUNITY PLAN POLICY AREA: 10-MT-T5-MU-02, MID-RISE IN GREEN HILLS/MIDTOWN OVERLAY (8-20 STORIES) BUILDING SETBACKS FRONT 0'-15' Measured from back of sidewalk SIDE 0' Measured from back of sidewalk REAR 20' MAX HEIGHT: 105' BUFFER YARDS: N/A MAX FAR: 3.00 MAX ISR: 0.90 PROPOSED DEVELOPMENT SUMMARY APPLICATION DATE: 11 / 02 / 2017 SP NUMBER: 2017SP-095-001 ZONING: SP [COMMERCIAL MIXED USE] LAND USE: COMMERCIAL, OFFICE LAND USE SF: 210,000 SF (GENERAL OFFICE) 26,000 SF (ORI-A PERMITTED USES, PLUS FURNITURE STORE AND NANO BREWERY) BULK REGULATIONS: BUILDING SETBACKS FRONT 0'-15' Measured from back of sidewalk SIDE 0' Measured from back of sidewalk REAR 0' BUILDING HEIGHT: 222' (Measured from Chet Atkins Pl) 215' (Measured from 19th Ave) BUILDING STORIES: 15 STORIES PROPOSED FAR: 7.10 MAX ISR: 0.97 PARKING SUMMARY SEE CHART BELOW REQUIRED PARKING STATEMENT: BASED ON METRO REQUIREMENTS FOR USES. [17.20.030] REQUIRED BICYCLE STATEMENT: BASED ON METRO REQUIREMENTS [BL2014-714] SEE TRANSPORTATION DEMAND MANAGEMENT PROGRAM SECTION ON THIS SHEET DEVELOPMENT STANDARDS 1. Buildings shall avoid continuous uninterrupted blank facades. At a minimum, the facade plane shall be interrupted by one of the following for every fifty (50) linear feet of street frontage: · A change in building material · A horizontal undulation in the building facade of three (3) feet or greater · A window, porch, stoop or balcony 2. Sidewalks shall be constructed to the standard of the Major and Collector Street Plan or, if on a local street, to local street standards. The build-to zone for alternative zoning districts shall be measured shall be measured from the Standard right-of-way line as established by the table entitled “Standard Street Right-of-Way Widths” in the Major and Collector Street Plan. GENERAL NOTES 1. Any standard not specifically addressed herein shall comply with the ORI-A base zoning requirements as of the application date of this Preliminary SP. 2. Lot is to be served with public water and sanitary sewer. 3. Site, open spaces, water quality & detention facilities to be maintained by property owner or property owner's association. 4. Refuse collection, recycling and mechanical equipment shall be fully screened from public view by the combination of fences, walls or landscaping (Section 17.24.060 of the Metro Zoning Code). 5. The developer's final construction drawings shall comply with the design regulations established by the Department of Public Works. Final design may vary based on field conditions. 6. All work in the public right-of-way requires a permit from the Department of Public Works. 7. Storm water will be routed through a stormwater quality management system, sized per the design criteria set forth by the Metro Stormwater Management Manual. 8. Approval of any specific plan does not exempt any parcel shown on the plan or any development within the SP from compliance with all provisions of the Metro Zoning Code with respect to floodplain, steep slopes, unstable soils, sinkholes, rock outcroppings, streams, springs and critical lots. 9. If required, a subdivision plat will be submitted with the Final SP documents. 10. The final site plan/ building permit site plan shall depict the required public sidewalks, any required grass strip or frontage zone and the location of all existing and proposed vertical obstructions within the required sidewalk and grass strip or frontage zone. Prior to the issuance of use and occupancy permits, existing vertical obstructions shall be relocated outside of the required sidewalk. Vertical obstructions are only permitted within the required grass strip or frontage zone. 11. Billboards shall not be permitted. 12. Sidewalk construction to comply with MCSP. Sidewalks are to be located within dedicated R.O.W. 13. FEDERAL COMPLIANCE: All development within the boundaries of this plan shall meet the requirements of the Americans with Disabilities Act and the Fair Housing Act. ADA: http://www.ada.org US Justice Dept: http://www.justice.gov/crt/house/fairhousing/about_fairhousingact.html 14. 78-840 NOTE: Any excavation, fill or disturbance of the existing ground elevation must be done in accordance with Storm Water Management Ordinance No. 78/840 and approved by the Metropolitan Dept. of Water Services. 15. ACCESS NOTE: Metro Water Services shall be provided sufficient & unencumbered access in order to maintain and repair utilities in this site. 16. FIRE DEPT. NOTE: Fire-flow shall meet the requirements of the International Fire Code - 2012 Edition; as amended. 17. PRELIMINARY PLAN NOTE: Minor modifications to this Preliminary SP Plan may be approved by the planning commission or its designee based upon final architectural, engineering or site design and actual site conditions. All modifications shall be consistent with the principles and further the objectives of the approved plan. Modifications shall not be permitted, except through an ordinance approved by Metro Council that increase the permitted density or floor area, add uses not otherwise permitted, eliminate specific conditions or requirements contained in the plan as adopted through this enacting ordinance, or add vehicular access points not currently present or approved. 18. STORMWATER PRELIMINARY PLAN NOTE: Drawing is for illustration purposes to indicate the basic premise of the development, as it pertains to Stormwater approval / comments only. The final lot count and details of the plan shall be governed by the appropriate stormwater regulations at the time of final application. 19. DEVELOPMENT SCHEDULE: It is anticipated that the project will begin construction in the 2nd quarter of 2018 and will take 12-16 months to be completed. 20. FEMA NOTE: No portion of this parcel described hereon lies within flood hazard area in accordance with "Insurance Rate Map Panel No. 470040-0243F", dated: April 5, 2017 (panel not printed). 21. SURVEY NOTE: Topographic information and boundary information taken from surveys prepared by Barge Waggoner Sumner, & Cannon, Inc dated August 29, 2017. 22. BUFFER NOTE: The buffer along waterways will be an area where the surface is left in a natural state is not disturbed by construction activity. This is in accordance with the Stormwater Management Manual Volume 1 Regulations. 23. C/D NOTE: Size driveway culverts per the design criteria set forth by the Metro Stormwater Management Manual (Minimum driveway culvert in Metro ROW is 15" CMP). GENERAL PLAN CONSISTENCY LAND USE POLICY This site is located within the T5 MU District of the Midtown community plan. This Transect Category is intended to preserve, enhance, and create high-intensity urban mixed use neighborhoods with a development pattern that contains a diverse mix of residential and non-residential land T5 MU areas are intended to be among the most intense areas in Davidson County. T5 MU areas include some of Nashville’s major employment centers such as Midtown that represent several sectors of the economy including health care, finance, retail, the music industry, and lodging. T5 MU areas also include locations that are planned to evolve to a similar form and function. COMMUNITY PLAN COMPLIANCE The proposed development will provide commercial and transitional land uses to the nearby residential land uses. Access within the overall development is designed to be pedestrian friendly with crosswalks and sidewalks to provide safe interaction between pedestrian and vehicular traffic. The commercial building is oriented towards the street with building forms that compliment the adjacent neighborhoods. Lighting will be provided throughout the development to provide safety at buildings and vehicular and pedestrian areas while enhancing the character of the center. TRANSPORTATION DEMAND MANAGEMENT PROGRAM · This development will strive to implement TDM best practices. These goals will include limiting delivery times will be restricted to non-peak hours, informational kiosks with wayfinding finding to nearby SOV options as well as to encourage future tenants to stagger work hours, provide carpooling and offer to pay a percentage of employees transit services costs. · Centrally located bike storage will be provided to the future tenants of the building and will include lockers and cages for their equipment. Changing rooms and showers will be located within the amenity facilities of the development for safe use by the tenants. · Due to the addition of multiple bike stations in surrounding development, a ride share partner is not established for this site. Instead, 20 bike racks will be centrally located within the development for use by the general public. SITE DATA TRUCK MOVEMENT PLAN C1.1 LANDSCAPE PLAN L1.0 LANDSCAPE ARCHITECTURAL PLANS LEVEL 1 - 19TH AVE A.201 ARCHITECTURAL PLANS LEVEL 1 - CHET ATKINS LEVEL 6 - PARKING [TYPICAL] ISOMETRIC VIEWS WEST ELEVATION SOUTH & NORTH ELEVATIONS EAST ELEVATION RETAIL / LOBBY ELEVATIONS A.201.1 A.206 A.241 A.304.1 A.304.2 A.304.3 A.305 NORTH / SOUTH SITE SECTION EAST / WEST SITE SECTION A.307 A.308

PRELIMINARY SP 19TH & CHET ATKINS - nashville.govmeasured from chet atkins place) w 3' r.o.w. dedication along 19th 4' r.o.w. dedication along (in place of 8' sidewalk & creed investments

  • Upload
    vokhue

  • View
    238

  • Download
    1

Embed Size (px)

Citation preview

Page 1: PRELIMINARY SP 19TH & CHET ATKINS - nashville.govmeasured from chet atkins place) w 3' r.o.w. dedication along 19th 4' r.o.w. dedication along (in place of 8' sidewalk & creed investments

17

13

50

97

0

C0.0

E. F

OS

TE

R

M. S

MA

IL

NO

S

CA

LE

NO

VE

MB

ER

2

, 2

01

7

19

TH

&

C

HE

T A

TK

IN

S O

FF

IC

E B

UIL

DIN

G

CR

EE

D IN

VE

ST

ME

NT

S C

OM

PA

NY

FO

R

19

TH

C

OU

NC

IL

D

IS

TR

IC

T, N

AS

HV

IL

LE

, D

AV

ID

ON

C

OU

NT

Y, T

EN

NE

SS

EE

SITE LAYOUT PLANC1.0

COVER SHEET

G:\1

71

35

-0

97

0\1

-C

IV

IL

E

NG

IN

EE

RIN

G\3

-P

LA

N S

HE

ET

S\P

RE

LIM

IN

AR

Y S

P\0

97

0 C

OV

ER

.D

WG

PL

OT

TE

D B

Y E

VA

N F

OS

TE

R O

N: 1

2/2

8/2

01

7 9

:0

2 A

M L

AS

T U

PD

AT

ED

B

Y E

BF

O

N: 1

2/2

8/2

01

7 9

:0

0 A

M

JO

B N

O.

WK

. O

RD

ER

SC

AL

E:

DA

TE

:

DR

AW

N:

RE

VIS

IO

NS

DE

SIG

NE

D:

EXISTING CONDITIONS & DEMOLITION PLANC0.2

SITE19TH & CHET ATKINS

OFFICE BUILDING

PRELIMINARY SP

LOCATION: 821, 823, 825, & 827 19TH AVE S, NASHVILLE, TN

Know what's below.before you dig.Call

METRO CASE # 2017SP-095-001

COVER SHEETC0.0

INDEX OF SHEETS

OWNER/DEVELOPER

DAVID CREED

CREED INVESTMENTS CO.

144 2ND AVE N, SUITE 300

NASHVILLE, TN 37201

(615) 246-0222

[email protected]

LANDSCAPE ARCHITECTURE

RAGAN SMITH & ASSOCIATES, INC.

315 WOODLAND STREET

NASHVILLE, TN 37206

(615) 244-8591

CIVIL

BRAD SLAYDEN, PE

RAGAN SMITH & ASSOCIATES, INC.

315 WOODLAND STREET

NASHVILLE, TN 37206

(615) 244-8591

[email protected]

ARCHITECTURE

GRESHAM SMITH & PARTNERS

222 2ND AVE, SUITE 1400

NASHVILLE, TN 37201

(615) 770-8100

CONTACTS

CIVIL PLANS

SHEET DESCRIPTION

PURPOSE NOTE

The purpose of this SP is to rezone 0.76 acres to allow for the construction of a

mid-rise office building (±255,000 gsf)

EXISTING PROPERTY INFORMATION

COUNCIL DISTRICT NUMBER: 19

DISTRICT COUNCIL MEMBER: FREDDIE O'CONNELL

PROPERTY OWNER(1): 19TH AVE LAND PARTNERS, LLC

421 CHURCH STREET

NASHVILLE, TN 37219

PROPERTY OWNER(2): VERGES-JAMES, LLC

823 19TH AVENUE SOUTH

NASHVILLE, TN 37203

PARCELS & ACREAGE: (PARCELS 265, 266, 267, 268)

33,257 SF [0.76 AC]

EX. BUILDING SF: 6,069 SF TOTAL (3 BUILDINGS)

TAX MAP: 92-16

METRO GIS ID: 09216026500, 09216026600,

09216026700, 09216026800

STREET ADDRESS: 821, 823, 825, & 827 19TH AVE S

NASHVILLE, TN 37203

ZONING: ORI-A/OV-UZO, OFFICE/RESIDENTIAL

INTENSIVE ALTERNATIVE

LAND USE: COMMERCIAL, OFFICE, PARKING LOT

COMMUNITY PLAN: GREEN HILLS-MIDTOWN COMMUNITY

PLAN

POLICY AREA: 10-MT-T5-MU-02, MID-RISE IN GREEN

HILLS/MIDTOWN OVERLAY (8-20

STORIES)

BUILDING SETBACKS

FRONT 0'-15' Measured from back of sidewalk

SIDE 0' Measured from back of sidewalk

REAR 20'

MAX HEIGHT: 105'

BUFFER YARDS: N/A

MAX FAR: 3.00

MAX ISR: 0.90

PROPOSED DEVELOPMENT SUMMARY

APPLICATION DATE: 11 / 02 / 2017

SP NUMBER: 2017SP-095-001

ZONING: SP [COMMERCIAL MIXED USE]

LAND USE: COMMERCIAL, OFFICE

LAND USE SF: 210,000 SF (GENERAL OFFICE)

26,000 SF (ORI-A PERMITTED USES, PLUS

FURNITURE STORE AND NANO BREWERY)

BULK REGULATIONS:

BUILDING SETBACKS

FRONT 0'-15' Measured from back of sidewalk

SIDE 0' Measured from back of sidewalk

REAR 0'

BUILDING HEIGHT: 222' (Measured from Chet Atkins Pl)

215' (Measured from 19th Ave)

BUILDING STORIES: 15 STORIES

PROPOSED FAR: 7.10

MAX ISR: 0.97

PARKING SUMMARY SEE CHART BELOW

REQUIRED PARKING STATEMENT: BASED ON METRO REQUIREMENTS

FOR USES. [17.20.030]

REQUIRED BICYCLE STATEMENT: BASED ON METRO REQUIREMENTS

[BL2014-714]

SEE TRANSPORTATION DEMAND

MANAGEMENT PROGRAM SECTION

ON THIS SHEET

DEVELOPMENT STANDARDS

1. Buildings shall avoid continuous uninterrupted blank facades. At a minimum, the

facade plane shall be interrupted by one of the following for every fifty (50)

linear feet of street frontage:

· A change in building material

· A horizontal undulation in the building facade of three (3) feet or greater

· A window, porch, stoop or balcony

2. Sidewalks shall be constructed to the standard of the Major and Collector Street

Plan or, if on a local street, to local street standards. The build-to zone

for alternative zoning districts shall be measured shall be measured from the

Standard right-of-way line as established by the table entitled “Standard Street

Right-of-Way Widths” in the Major and Collector Street Plan.

GENERAL NOTES

1. Any standard not specifically addressed herein shall comply with the ORI-A

base zoning requirements as of the application date of this Preliminary SP.

2. Lot is to be served with public water and sanitary sewer.

3. Site, open spaces, water quality & detention facilities to be maintained by

property owner or property owner's association.

4. Refuse collection, recycling and mechanical equipment shall be fully screened

from public view by the combination of fences, walls or landscaping (Section

17.24.060 of the Metro Zoning Code).

5. The developer's final construction drawings shall comply with the design

regulations established by the Department of Public Works. Final design may

vary based on field conditions.

6. All work in the public right-of-way requires a permit from the Department of

Public Works.

7. Storm water will be routed through a stormwater quality management system,

sized per the design criteria set forth by the Metro Stormwater Management

Manual.

8. Approval of any specific plan does not exempt any parcel shown on the plan or

any development within the SP from compliance with all provisions of the Metro

Zoning Code with respect to floodplain, steep slopes, unstable soils, sinkholes,

rock outcroppings, streams, springs and critical lots.

9. If required, a subdivision plat will be submitted with the Final SP documents.

10. The final site plan/ building permit site plan shall depict the required public

sidewalks, any required grass strip or frontage zone and the location of all

existing and proposed vertical obstructions within the required sidewalk and

grass strip or frontage zone. Prior to the issuance of use and occupancy

permits, existing vertical obstructions shall be relocated outside of the required

sidewalk. Vertical obstructions are only permitted within the required grass strip

or frontage zone.

11. Billboards shall not be permitted.

12. Sidewalk construction to comply with MCSP. Sidewalks are to be located within

dedicated R.O.W.

13. FEDERAL COMPLIANCE: All development within the boundaries of this plan

shall meet the requirements of the Americans with Disabilities Act and the Fair

Housing Act.

ADA: http://www.ada.org

US Justice Dept: http://www.justice.gov/crt/house/fairhousing/about_fairhousingact.html

14. 78-840 NOTE: Any excavation, fill or disturbance of the existing ground

elevation must be done in accordance with Storm Water Management

Ordinance No. 78/840 and approved by the Metropolitan Dept. of Water

Services.

15. ACCESS NOTE: Metro Water Services shall be provided sufficient &

unencumbered access in order to maintain and repair utilities in this site.

16. FIRE DEPT. NOTE: Fire-flow shall meet the requirements of the International

Fire Code - 2012 Edition; as amended.

17. PRELIMINARY PLAN NOTE: Minor modifications to this Preliminary SP Plan

may be approved by the planning commission or its designee based upon final

architectural, engineering or site design and actual site conditions. All

modifications shall be consistent with the principles and further the objectives of

the approved plan. Modifications shall not be permitted, except through an

ordinance approved by Metro Council that increase the permitted density or

floor area, add uses not otherwise permitted, eliminate specific conditions or

requirements contained in the plan as adopted through this enacting ordinance,

or add vehicular access points not currently present or approved.

18. STORMWATER PRELIMINARY PLAN NOTE: Drawing is for illustration

purposes to indicate the basic premise of the development, as it pertains to

Stormwater approval / comments only. The final lot count and details of the

plan shall be governed by the appropriate stormwater regulations at the time of

final application.

19. DEVELOPMENT SCHEDULE: It is anticipated that the project will begin

construction in the 2nd quarter of 2018 and will take 12-16 months to be

completed.

20. FEMA NOTE: No portion of this parcel described hereon lies within flood hazard

area in accordance with "Insurance Rate Map Panel No. 470040-0243F", dated:

April 5, 2017 (panel not printed).

21. SURVEY NOTE: Topographic information and boundary information taken from

surveys prepared by Barge Waggoner Sumner, & Cannon, Inc dated August 29,

2017.

22. BUFFER NOTE: The buffer along waterways will be an area where the surface

is left in a natural state is not disturbed by construction activity. This is in

accordance with the Stormwater Management Manual Volume 1 Regulations.

23. C/D NOTE: Size driveway culverts per the design criteria set forth by the Metro

Stormwater Management Manual (Minimum driveway culvert in Metro ROW is

15" CMP).

GENERAL PLAN CONSISTENCY

LAND USE POLICY

This site is located within the T5 MU District of the Midtown community plan. This

Transect Category is intended to preserve, enhance, and create high-intensity urban

mixed use neighborhoods with a development pattern that contains a diverse mix of

residential and non-residential land T5 MU areas are intended to be among the most

intense areas in Davidson County. T5 MU areas include some of Nashville’s major

employment centers such as Midtown that represent several sectors of the economy

including health care, finance, retail, the music industry, and lodging. T5 MU areas

also include locations that are planned to evolve to a similar form and function.

COMMUNITY PLAN COMPLIANCE

The proposed development will provide commercial and transitional land uses to the

nearby residential land uses. Access within the overall development is designed to

be pedestrian friendly with crosswalks and sidewalks to provide safe interaction

between pedestrian and vehicular traffic. The commercial building is oriented

towards the street with building forms that compliment the adjacent neighborhoods.

Lighting will be provided throughout the development to provide safety at buildings

and vehicular and pedestrian areas while enhancing the character of the center.

TRANSPORTATION DEMAND MANAGEMENT PROGRAM

· This development will strive to implement TDM best practices. These

goals will include limiting delivery times will be restricted to non-peak

hours, informational kiosks with wayfinding finding to nearby SOV

options as well as to encourage future tenants to stagger work hours,

provide carpooling and offer to pay a percentage of employees transit

services costs.

· Centrally located bike storage will be provided to the future tenants of

the building and will include lockers and cages for their equipment.

Changing rooms and showers will be located within the amenity

facilities of the development for safe use by the tenants.

· Due to the addition of multiple bike stations in surrounding

development, a ride share partner is not established for this site.

Instead, 20 bike racks will be centrally located within the development

for use by the general public.

SITE DATA

TRUCK MOVEMENT PLANC1.1

LANDSCAPE PLANL1.0

LANDSCAPE ARCHITECTURAL PLANS

LEVEL 1 - 19TH AVE A.201

ARCHITECTURAL PLANS

LEVEL 1 - CHET ATKINS

LEVEL 6 - PARKING [TYPICAL]

ISOMETRIC VIEWS

WEST ELEVATION

SOUTH & NORTH ELEVATIONS

EAST ELEVATION

RETAIL / LOBBY ELEVATIONS

A.201.1

A.206

A.241

A.304.1

A.304.2

A.304.3

A.305

NORTH / SOUTH SITE SECTION

EAST / WEST SITE SECTION

A.307

A.308

Page 2: PRELIMINARY SP 19TH & CHET ATKINS - nashville.govmeasured from chet atkins place) w 3' r.o.w. dedication along 19th 4' r.o.w. dedication along (in place of 8' sidewalk & creed investments

233

(264)

THEODORE H., PAILET, ET.AL.

INST. NO. 20141230-0118676, R.O.D.C.

230

229

O.B. HAYES SECOND

PLAN OF SMALL LOTS

CHANCERY COURT BOOK 1, PAGE 81

(269)

THEODORE H., PAILET, ET.AL.

INST. NO. 20141230-0118676, R.O.D.C.

234

(268)

CHET ATKINS PLACE

(FORMERLY SOUTH STREET

50' PUBLIC R.O.W.)

232

(264)

THEODORE H., PAILET, ET.AL.

INST. NO. 20141230-0118676, R.O.D.C.

230

229

O.B. HAYES SECOND

PLAN OF SMALL LOTS

CHANCERY COURT BOOK 1, PAGE 81

A

L

L

E

Y

#

4

4

7

(

1

6

'

P

U

B

L

I

C

R

.

O

.

W

.

)

BENCHMARK

19

TH

A

VE

NU

E S

OU

TH

AL

LE

Y #

44

6

(264)

THEODORE H., PAILET, ET.AL.

INST. NO. 20141230-0118676, R.O.D.C.

166.37'

50.00'

102.57'

7

5

.

7

3

'

1

3

8

.

9

7

'

91.77'

R.R. SPIKE IN P/T/LT POLE

#09526378

ELEV. 489.20

(NAVD-1988/REF/2007/GEOID03)

229

230

231

O.B. HAYES SECOND

PLAN OF SMALL LOTS

CHANCERY COURT BOOK 1, PAGE 81

(5

8' P

UB

LIC

R

.O

.W

.)

(1

6' P

UB

LIC

R

.O

.W

.)

(267)

(265)

N 8° 21' 36" E

192.84'

50.00'

50.00'

50.00'

50.00'

50.00'

50.00'

50.00'

42.84'

S 82° 37' 36" E 166.12'

S 82° 37' 36" E 166.25'

S 82° 37' 36" E

(266)

200.00'

P

&

T

P

&

T

P

&

T

P

&

T

6''W6''W6''W6''W

S 82° 37' 36" E

26.50'

S 82° 37' 36" E - 115.50'

N

5

6

°

0

3

'

1

8

"

E

1

0

.

8

6

'

N 82° 37' 36" W 166.00'

S 8° 30' 03" W

10

''S

P&T

P

&

T

P&

T

P&T

P&T

P&T

P&T

P&

T

P&

T

P&

T

P&

T

S

S

S

BENCHMARK

PKN IN P/T/L/T POLE

#09536015

ELEV. 504.21

(NAVD-1988/REF/2007/GEOID03)

CONSTRUCTION TRAILER

(TEMPORARY)

2-STORY BRICK

AREA = 865 SF

1-STORY BRICK

AREA = 1475 SF

2-STORY BRICK

AREA = 1432 SF

N 7° 24' 22" E

1.40'

N 7° 24' 22" E

1.40'

S 82° 37' 36" E

16.46'

10''S

10''S

8''S

8''S

W

W

W

W

W

W

W

6''W

6''W

6''W

6''W

6''W

6''W

6''W

233

(264)

THEODORE H., PAILET, ET.AL.

INST. NO. 20141230-0118676, R.O.D.C.

230

229

O.B. HAYES SECOND

PLAN OF SMALL LOTS

CHANCERY COURT BOOK 1, PAGE 81

(269)

THEODORE H., PAILET, ET.AL.

INST. NO. 20141230-0118676, R.O.D.C.

234

(268)

232

(264)

THEODORE H., PAILET, ET.AL.

INST. NO. 20141230-0118676, R.O.D.C.

230

229

O.B. HAYES SECOND

PLAN OF SMALL LOTS

CHANCERY COURT BOOK 1, PAGE 81

BENCHMARK

19

TH

A

VE

NU

E S

OU

TH

(264)

THEODORE H., PAILET, ET.AL.

INST. NO. 20141230-0118676, R.O.D.C.

R.R. SPIKE IN P/T/LT POLE

#09526378

ELEV. 489.20

(NAVD-1988/REF/2007/GEOID03)

229

230

231

O.B. HAYES SECOND

PLAN OF SMALL LOTS

CHANCERY COURT BOOK 1, PAGE 81

(267)

(265)

(266)

6''W6''W

P&T

P&T

P&

T

S

BENCHMARK

PKN IN P/T/L/T POLE

#09536015

ELEV. 504.21

(NAVD-1988/REF/2007/GEOID03)

CONSTRUCTION TRAILER

(TEMPORARY)

2-STORY BRICK

AREA = 865 SF

1-STORY BRICK

AREA = 1475 SF

2-STORY BRICK

AREA = 1432 SF

10''S

8''S

W

W

W

6''W

6''W

6''W

17

13

50

97

0

C0.2

E. F

OS

TE

R

M. S

MA

IL

1"=

20

'

NO

VE

MB

ER

2

, 2

01

7

19

TH

&

C

HE

T A

TK

IN

S O

FF

IC

E B

UIL

DIN

G

CR

EE

D IN

VE

ST

ME

NT

S C

OM

PA

NY

FO

R

19

TH

C

OU

NC

IL

D

IS

TR

IC

T, N

AS

HV

IL

LE

, D

AV

ID

ON

C

OU

NT

Y, T

EN

NE

SS

EE

G:\1

71

35

-0

97

0\1

-C

IV

IL

E

NG

IN

EE

RIN

G\3

-P

LA

N S

HE

ET

S\P

RE

LIM

IN

AR

Y S

P\0

97

0 E

XIS

TIN

G.D

WG

PL

OT

TE

D B

Y E

VA

N F

OS

TE

R O

N: 1

2/2

1/2

01

7 2

:5

7 P

M L

AS

T U

PD

AT

ED

B

Y B

AP

O

N: 1

2/2

0/2

01

7 9

:5

0 A

M

EXISTING

CONDITIONS &

DEMOLITION PLAN

JO

B N

O.

WK

. O

RD

ER

SC

AL

E:

DA

TE

:

DR

AW

N:

RE

VIS

IO

NS

DE

SIG

NE

D:

Know what's below.before you dig.Call

SITE

LOCATION: 821, 823, 825, & 827 19TH AVE S, NASHVILLE, TN

15 -20% SLOPES

25% > SLOPES

LEGEND

EXISTING STRUCTURES NOTE:

DEMOLITION PLAN

NOTES:

METRO CASE # 2017SP-095-001

Page 3: PRELIMINARY SP 19TH & CHET ATKINS - nashville.govmeasured from chet atkins place) w 3' r.o.w. dedication along 19th 4' r.o.w. dedication along (in place of 8' sidewalk & creed investments

LVL 7

83'

±2,000 SQFT GR

LVL 15

203'

(T.O.FLOOR)

222'

(T.O. PARAPET)

226'

(T.O. PARAPET)

BUILDING HEIGHTS

(MEASURED FROM CHET ATKINS PLACE)

INSET SCALE: 1"=60'

GREEN ROOF

SPACE

CHET ATKINS PLACE

(FORMERLY SOUTH STREET

50' PUBLIC R.O.W.)

A

L

L

E

Y

#

4

4

7

(

1

6

'

P

U

B

L

I

C

R

.

O

.

W

.

)

19

TH

A

VE

NU

E S

OU

TH

AL

LE

Y #

44

6

(58' P

UB

LIC

R

.O

.W

.)

(16' P

UB

LIC

R

.O

.W

.)

P

&

T

P

&

T

6''W6''W6''W6''W

10

''S

P&

T

P&T

P&T

P&T

P&T

P&

T

P&

T

P&

T

P&

T

S

S

S

10''S

10''S

8''S

8''S

W

W

W

W

W

W

W

6''W

6''W

6''W

6''W

6''W

6''W

6''W

W

3' BIKE LANE

4' GRASS STRIP

8' SIDEWALK

4' FRONTAGE ZONE

4' 8' 4'

R10'

R10'

PROPOSED WATER

SERVICE

PROPOSED SANITARY

SERVICE

25'

12.2'

1.9'

1.3'

0'

0'

3' R.O.W. DEDICATION ALONG 19TH

AVE FRONTAGE

4' R.O.W. DEDICATION ALONG

ALLEY #446 FRONTAGE

4' R.O.W. DEDICATION ALONG

ALLEY #447 FRONTAGE

DRIVEWAY RAMP

MPW ST-324

VALET/DRIVE SHARE

DROP LANE

LOBBY

ST

OR

MW

AT

ER

VA

UL

T

RCP STORM

CONNECTION

WATER QUALITY

STRUCTURE

[WAIVER PENDING]

0'

0'

RAMP DOWN TO

BELOW GRADE

PARKING

3'

34'

12'

24.6'

R4'

R4'

25.5'

187.8'

OUTDOOR/PUBLIC

BICYCLE PARKING AREA

(20 SPACES)

20'

20' PROPOSED ALLEY

PAVEMENT WIDTH

PARKING

GATE

PARKING

GATE

DAILY SERVICE DELIVERY AREA

CHET ATKINS PLACE

(FORMERLY SOUTH STREET

50' PUBLIC R.O.W.)

A

L

L

E

Y

#

4

4

7

(

1

6

'

P

U

B

L

I

C

R

.

O

.

W

.

)

19

TH

A

VE

NU

E S

OU

TH

AL

LE

Y #

44

6

(58' P

UB

LIC

R

.O

.W

.)

(16' P

UB

LIC

R

.O

.W

.)

P

&

T

P

&

T

6''W6''W6''W6''W

10

''S

P&

T

P&T

P&T

P&T

P&T

P&

T

P&

T

P&

T

P&

T

S

S

S

10''S

10''S

8''S

8''S

W

W

W

W

W

W

W

6''W

6''W

6''W

6''W

6''W

6''W

6''W

4' GRASS STRIP

10' SIDEWALK

(IN PLACE OF 8' SIDEWALK &

4' FRONTAGE ZONE)

4'

10'

R10'

DAILY PARKING

ENTRY/EXIT TO ABOVE

GRADE PARKING

R10'

4' R.O.W. DEDICATION ALONG CHET

ATKINS PLACE FRONTAGE

T

R

A

S

H

C

O

M

P

A

C

T

O

R

19TH AVE ACCESS

(BELOW)

DRIVEWAY RAMP

MPW ST-324

R10'

188.1'

151'

26'

R1.2'

0.9'

0.8'

26'

SCISSOR

LIFT

SCISSOR

LIFT

20'

20' PROPOSED ALLEY

PAVEMENT WIDTH

10.9'

29.7'

EXISTING CURB CUT

PARKING

GATE

PARKING

GATE

32'

100'

"NO STANDING ANY TIME" SIGN

MUTCD No. R7-4 (TYP)

17

13

50

97

0

C1.0

E. F

OS

TE

R

M. S

MA

IL

1"=

20

'

NO

VE

MB

ER

2

, 2

01

7

19

TH

&

C

HE

T A

TK

IN

S O

FF

IC

E B

UIL

DIN

G

CR

EE

D IN

VE

ST

ME

NT

S C

OM

PA

NY

FO

R

19

TH

C

OU

NC

IL

D

IS

TR

IC

T, N

AS

HV

IL

LE

, D

AV

ID

ON

C

OU

NT

Y, T

EN

NE

SS

EE

G:\1

71

35

-0

97

0\1

-C

IV

IL

E

NG

IN

EE

RIN

G\3

-P

LA

N S

HE

ET

S\P

RE

LIM

IN

AR

Y S

P\0

97

0 L

AY

OU

T.D

WG

PL

OT

TE

D B

Y E

VA

N F

OS

TE

R O

N: 1

2/2

8/2

01

7 9

:0

2 A

M L

AS

T U

PD

AT

ED

B

Y E

BF

O

N: 1

2/2

8/2

01

7 9

:0

1 A

M

SITE LAYOUT PLAN

JO

B N

O.

WK

. O

RD

ER

SC

AL

E:

DA

TE

:

DR

AW

N:

RE

VIS

IO

NS

DE

SIG

NE

D:

METRO CASE # 2017SP-095-001

HEAVY DUTY

ASPHALT PAVEMENT

NOTE

The final site plan/ building permit site plan shall depict the required

public sidewalks, any required grass strip or frontage zone and the

location of all existing and proposed vertical obstructions within the

required sidewalk and grass strip or frontage zone. Prior to the

issuance of use and occupancy permits, existing vertical obstructions

shall be relocated outside of the required sidewalk. Vertical

obstructions are only permitted within the required grass strip or

frontage zone.

STORM WATER NOTE

On-site water quality and detention requirements will be provided by

the proposed stormwater vault and water quality unit. The proposed

building will also contain a series of rooftop pocket parks that will

contain extensive green roof space to accommodate pavers and green

space zones. See inset for approximate locations.

METRO PUBLIC WORKS NOTES

1. The developer's final construction drawings shall comply with the

design regulations established by the Department of Public

Works, in effect at the time of the approval of the preliminary

development plan or final development plan or building permit, as

applicable. Final design may vary based on field conditions.

2. Submit recorded copy of ROW dedication prior to building permit

approval by MPW.

PAVEMENT LEGEND

CONCRETE PAVEMENT

CONCRETE WALK

GRASSY AREA

PER TIS RECOMMENDATIONS:

THE EASTBOUND APPROACH OF CHET ATKINS PLACE AT 19TH AVENUE SOUTH INTERSECTION

SHOULD BE STRIPED WITH SEPARATE LEFT AND RIGHT (AND THROUGH) TURN LANES. THE RIGHT

TURN LANE SHOULD INCLUDE A MINIMUM OF 100 FEET OF STORAGE. ADDITIONALLY, THE EXISTING

PARKING ON THE NORTH SIDE OF CHET ATKINS PLACE SHOULD BE REMOVED WITHIN 100 FEET OF

THE STOP LINE AT THE 19TH AVENUE SOUTH INTERSECTION. THE APPROACHING RESTRIPING

SHOULD INCLUDE A NEW STOP BAR AND A PEDESTRIAN CROSSWALK ALONG CHET ATKINS PLACE

SITE PLAN:

19TH AVENUE SOUTH ENTRANCE LEVEL

SITE PLAN:

CHET ATKINS PLACE ENTRANCE LEVEL

Page 4: PRELIMINARY SP 19TH & CHET ATKINS - nashville.govmeasured from chet atkins place) w 3' r.o.w. dedication along 19th 4' r.o.w. dedication along (in place of 8' sidewalk & creed investments

17

13

50

97

0

C1.1

E. F

OS

TE

R

M. S

MA

IL

1"=

20

'

NO

VE

MB

ER

2

, 2

01

7

19

TH

&

C

HE

T A

TK

IN

S O

FF

IC

E B

UIL

DIN

G

CR

EE

D IN

VE

ST

ME

NT

S C

OM

PA

NY

FO

R

19

TH

C

OU

NC

IL

D

IS

TR

IC

T, N

AS

HV

IL

LE

, D

AV

ID

ON

C

OU

NT

Y, T

EN

NE

SS

EE

G:\1

71

35

-0

97

0\1

-C

IV

IL

E

NG

IN

EE

RIN

G\3

-P

LA

N S

HE

ET

S\P

RE

LIM

IN

AR

Y S

P\0

97

0 L

AY

OU

T.D

WG

PL

OT

TE

D B

Y E

VA

N F

OS

TE

R O

N: 1

2/2

2/2

01

7 1

0:4

9 A

M

LA

ST

U

PD

AT

ED

B

Y E

BF

O

N: 1

2/2

2/2

01

7 1

0:4

8 A

M

TRUCK MOVEMENT

PLAN

JO

B N

O.

WK

. O

RD

ER

SC

AL

E:

DA

TE

:

DR

AW

N:

RE

VIS

IO

NS

DE

SIG

NE

D:

METRO CASE # 2017SP-095-001

PASSENGER CAR MOVEMENTS

SEMI TRUCK ROUTE

Page 5: PRELIMINARY SP 19TH & CHET ATKINS - nashville.govmeasured from chet atkins place) w 3' r.o.w. dedication along 19th 4' r.o.w. dedication along (in place of 8' sidewalk & creed investments

CHET ATKINS PLACE

(FORMERLY SOUTH STREET

50' PUBLIC R.O.W.)

A

L

L

E

Y

#

4

4

7

(

1

6

'

P

U

B

L

I

C

R

.

O

.

W

.

)

19

TH

A

VE

NU

E S

OU

TH

ALL

EY

#

44

6

(58' P

UB

LIC

R

.O

.W

.)

(16' P

UB

LIC

R

.O

.W

.)

P

&

T

P

&

T

P&

T

P&T

P&T

P&T

P&T

P&

T

P&

T

P&

T

P&

T

17

13

50

97

0

L1.0

E. F

OS

TE

R

M. S

MA

IL

1"=

20

'

NO

VE

MB

ER

2

, 2

01

7

19

TH

&

C

HE

T A

TK

IN

S O

FF

IC

E B

UIL

DIN

G

CR

EE

D IN

VE

ST

ME

NT

S C

OM

PA

NY

FO

R

19

TH

C

OU

NC

IL

D

IS

TR

IC

T, N

AS

HV

IL

LE

, D

AV

ID

ON

C

OU

NT

Y, T

EN

NE

SS

EE

G:\1

71

35

-0

97

0\1

-C

IV

IL

E

NG

IN

EE

RIN

G\3

-P

LA

N S

HE

ET

S\P

RE

LIM

IN

AR

Y S

P\0

97

0 L

AN

DS

CA

PE

.D

WG

PL

OT

TE

D B

Y E

VA

N F

OS

TE

R O

N: 1

2/2

1/2

01

7 2

:5

8 P

M L

AS

T U

PD

AT

ED

B

Y E

BF

O

N: 1

1/2

2/2

01

7 8

:4

1 A

M

LANDSCAPE PLAN

JO

B N

O.

WK

. O

RD

ER

SC

AL

E:

DA

TE

:

DR

AW

N:

RE

VIS

IO

NS

DE

SIG

NE

D:

Know what's below.before you dig.Call

METRO CASE # 2017SP-095-001

GENERAL LANDSCAPE NOTES:

1. SEE URBAN FORESTRY CHECKLIST PRIOR TO ORDERING AND INSTALLING PLANTS.

ANY/ALL FIELD ADJUSTMENTS SHOULD BE COORDINATED WITH THE LANDSCAPE

ARCHITECT AND APPROVED BY THE METRO URBAN FORESTER.

2. SOD IS PROPOSED FOR THIS DEVELOPMENT, HOWEVER, OWNER MAY CHOOSE TO

SEED IN LIEU OF SOD. OWNER APPROVAL SHOULD BE OBTAIN FOR THIS REQUEST.

3. NO TREE SHALL BE PLANTED WITHIN 15' OF AN EXISTING OR FUTURE POWER POLE.

SEE NOTE ONE ABOVE FOR ADDITIONAL REQUIREMENTS.

4. CITY REQUIREMENT TO NOT PLANT OBSTRUCTING TREES WITHIN THE SITE TRIANGLE

PREVENTS PLANTING OF ANY TREES WITHIN THE PLANTING STRIPS BEHIND THE

STREET CURB. IN LIEU OF TREES, THE STRIPS WILL BE LANDSCAPED WITH OTHER

PLANTINGS NOT TO EXCEED HEIGHT REQUIREMENTS.

Page 6: PRELIMINARY SP 19TH & CHET ATKINS - nashville.govmeasured from chet atkins place) w 3' r.o.w. dedication along 19th 4' r.o.w. dedication along (in place of 8' sidewalk & creed investments

A.3031

A.301

1

A.304 1

A.302

1

574 SFBOH

242 SFSTAIR SHAFT

162 SFFSAE

215 SF

VERTICALCIRCULATION 190 SF

VERTICALCIRCULATION

1232 SFOFFICE LOBBY

2177 SF

SP LISTEDUSES

66 S

F

LOBB

YLA

ND

SCAP

E

1825 SF

OFFICE LOBBY -OUTDOOR

6977 SF

SP LISTEDUSES

610 SFBOH

229 SFSTAIR SHAFT

501 SF

STAIR SHAFT/TRANSFER

1351 SFBOH

1098 SF

OPEN TOBELOW

1534 SFPARKING

PLAN FOR SPECIALTY WOODLOOK SOFFIT AND LINEARLIGHITNG IN THIS OUTDOORLOBBY ZONE

SPECIALTY TILE ANDPAVER SYSTEM.TRANSITION TO REGULARCONCRETE AND TRAFICCOATING AT RAMP TOBELOW GRADE PARKING

SSG LOBBY CURTANWALLTO SOFFIT WITH 10' X 10'IGU GLASS LITES

IN GRADE UPLIGHTING ATEDGE OF PERIMETER ANDGLASS LOBBY WALL

PERFORATED LINEAR METALPANEL SOFFIT WITHINTEGRATED LIGHTING.

LIGHTING LEVELS:100 LM MIN AT ENTRY50 LM ON RAMPS AND5LM IN PARKING

LIGHTING LEVELS:100 LM MIN AT ENTRY50 LM ON RAMPS AND5LM IN PARKING

A303

2

A302 1

A3041

A303

1

768 SF

OFFICE LOBBY -OUTDOOR

5634 SF

OFFICE LOBBY -OUTDOOR

319 SF

OFFICE LOBBY -OUTDOOR

146 SF

LOBBYLANDSCAPE

SCISSORLIFT

13.5

6%

12.52%

5.97%

137 SFSTAIR SHAFT

1022 SFSTORAGE

800 SFBOH

863 SFCORRIDOR

STAIR UPFROMRETAILPARKING

DSD TRUCKPARKING

LOCATION

222 2nd Ave SNashville, TN

37201615.770.8100

Dra

wn

By:

Che

cked

By:

Appr

oved

By:

DATE:PROJECT:

G S & PR

G R E S H A MS M I T H A N DP A R T N E R S

Design ServicesFor The Built

Environment

LINE IS 3 INCHES WHEN PRINTED FULL SIZEFULL SHEET SIZE = 24"X36"

www.greshamsmith.com

PRELIMIN

ARY -

NOT FOR

CONSTRUCTION

12/2

1/20

17 1

0:32

:57

AMBI

M 3

60:/

/Cre

ed In

vest

men

ts/1

9255

09_C

het_

19th

_112

1_Ar

ch.rv

t

LVL 1 - 19TH AVEACCESS

A20142885.0012.12.2017

Auth

or

Chec

ker

Appr

over

19th

and

Che

tOf

fice

Tow

er82

7 19

TH A

VE

0' 48'32'16'8' 1/16" = 1'-0"1 LVL 1 - 19TH CC

RevisionNo. Date Description

Page 7: PRELIMINARY SP 19TH & CHET ATKINS - nashville.govmeasured from chet atkins place) w 3' r.o.w. dedication along 19th 4' r.o.w. dedication along (in place of 8' sidewalk & creed investments

A.3031

A.301

1

A.304 1

A.302

1

15' SETBACK

4' FRONTAGEZONE

15' - 0"4' - 0"

CHET ATKINS PLACE

19TH

AVE

PUBLIC R.O.W

.

DAILY PARKINGENTRY/EXIT TOABOVE GRADEPARKING

EXISTING CURB CUTNEXT TO ALLEYACCESS

SITESLOPES UP

TO CHETATKINS

ALLEYSLOPES UP

TO CHETATKINS

BOH

OPEN TO BELOW

SCISSORLIFT

MORRISAPARTMENTS

PUBL

IC R

.O.W

.

AMERICANAAPARTMENTS

10.24°

TRAS

HCO

MPA

CTO

R

26' X 20' ROLL UPDOOR

26' X 20' ROLL UPDOOR

2649 SFBOH

239 SFSTAIR SHAFT

160 SFFSAE

214 SF

ELEVATORVERTICAL

CIRCULATION189 SF

ELEVATORVERTICAL

CIRCULATION

1381 SF

SITEPAVEMENT

611 SFBOH

229 SFSTAIR SHAFT

288 SFSTAIR SHAFT

1405 SFPARKING

OPEN TO BELOW

LIGHTING LEVELS:100 LM MIN AT ENTRY50 LM ON RAMPS AND5LM IN PARKING

SEPARATE LINE ITEM FOR SITE IMPROVEMENT:IMPROVED INTERESECTION AT 19TH AND CHET.ALIGNING INTERSECTIONS.

A303

2

A302 1

A3041

A303

1

645 SF

SITEPAVEMENT

33' -

0"

OPEN TO BELOW

OPEN TO BELOW

222 2nd Ave SNashville, TN

37201615.770.8100

Dra

wn

By:

Che

cked

By:

Appr

oved

By:

DATE:PROJECT:

G S & PR

G R E S H A MS M I T H A N DP A R T N E R S

Design ServicesFor The Built

Environment

LINE IS 3 INCHES WHEN PRINTED FULL SIZEFULL SHEET SIZE = 24"X36"

www.greshamsmith.com

PRELIMIN

ARY -

NOT FOR

CONSTRUCTION

12/2

1/20

17 1

0:33

:00

AMBI

M 3

60:/

/Cre

ed In

vest

men

ts/1

9255

09_C

het_

19th

_112

1_Ar

ch.rv

t

LVL 1 - CHET AVEACCESS

A201.142885.0012.12.2017

Auth

or

Chec

ker

Appr

over

19th

and

Che

tOf

fice

Tow

er82

7 19

TH A

VE

0' 48'32'16'8' 1/16" = 1'-0"1 LVL 1 - CHET DOCK LEVEL

RevisionNo. Date Description

Page 8: PRELIMINARY SP 19TH & CHET ATKINS - nashville.govmeasured from chet atkins place) w 3' r.o.w. dedication along 19th 4' r.o.w. dedication along (in place of 8' sidewalk & creed investments

A.3031

A.301

1

A.304 1

A.302

1

27375 SFPARKING

239 SFSTAIR SHAFT

160 SFFSAE

214 SF

ELEVATORVERTICAL

CIRCULATION189 SF

ELEVATORVERTICAL

CIRCULATION

MORRISAPARTMENTS

AMERICANAAPARTMENTS

A303

2

A302 1

A3041

A303

1

13.8

9%

13.8

9%

222 2nd Ave SNashville, TN

37201615.770.8100

Dra

wn

By:

Che

cked

By:

Appr

oved

By:

DATE:PROJECT:

G S & PR

G R E S H A MS M I T H A N DP A R T N E R S

Design ServicesFor The Built

Environment

LINE IS 3 INCHES WHEN PRINTED FULL SIZEFULL SHEET SIZE = 24"X36"

www.greshamsmith.com

PRELIMIN

ARY -

NOT FOR

CONSTRUCTION

12/2

1/20

17 1

0:33

:02

AMBI

M 3

60:/

/Cre

ed In

vest

men

ts/1

9255

09_C

het_

19th

_112

1_Ar

ch.rv

t

LVL 6 - TYP PARKING

A20642885.0012.12.2017

Auth

or

Chec

ker

Appr

over

19th

and

Che

tOf

fice

Tow

er82

7 19

TH A

VE

1/16" = 1'-0"1 LVL 6 - TYP. PARKING

RevisionNo. Date Description

Page 9: PRELIMINARY SP 19TH & CHET ATKINS - nashville.govmeasured from chet atkins place) w 3' r.o.w. dedication along 19th 4' r.o.w. dedication along (in place of 8' sidewalk & creed investments
Page 10: PRELIMINARY SP 19TH & CHET ATKINS - nashville.govmeasured from chet atkins place) w 3' r.o.w. dedication along 19th 4' r.o.w. dedication along (in place of 8' sidewalk & creed investments
Page 11: PRELIMINARY SP 19TH & CHET ATKINS - nashville.govmeasured from chet atkins place) w 3' r.o.w. dedication along 19th 4' r.o.w. dedication along (in place of 8' sidewalk & creed investments
Page 12: PRELIMINARY SP 19TH & CHET ATKINS - nashville.govmeasured from chet atkins place) w 3' r.o.w. dedication along 19th 4' r.o.w. dedication along (in place of 8' sidewalk & creed investments
Page 13: PRELIMINARY SP 19TH & CHET ATKINS - nashville.govmeasured from chet atkins place) w 3' r.o.w. dedication along 19th 4' r.o.w. dedication along (in place of 8' sidewalk & creed investments
Page 14: PRELIMINARY SP 19TH & CHET ATKINS - nashville.govmeasured from chet atkins place) w 3' r.o.w. dedication along 19th 4' r.o.w. dedication along (in place of 8' sidewalk & creed investments

LVL B1-19' - 6"

LVL 220' - 0"

LVL 332' - 6"

LVL 445' - 0"

LVL 557' - 6"

LVL 670' - 0"

LVL 7 - AMENITY83' - 0"

LVL 898' - 0"

LVL 9113' - 0"

LVL 10128' - 0"

LVL 11143' - 0"

LVL 13173' - 0"

LVL 14188' - 0"

LVL 15203' - 0"

LVL 12158' - 0"

190' - 0" ROOF OFADELICIA BEYOND

200' SITE WIDTH

50' WIDTH

32'STREETWIDTH

PROPERTY LINE

ADJACENTPROPERTYAIR SPACE

LVL B2-32' - 0"

ELEVATOR PITS-52' - 0"

LVL 1 - 19TH CC-7' - 0"

LVL 1 - CHET CC2' - 0"

LVL 1 - CHET DOCK LEVEL4' - 0"

OFFICE TOWER CONCRETE FINISHES:FLOOR FINISH TO BE CLASS "A"SOFFIT AND BEAMS TO BE CLASS "B"

TRAFFIC COATING ON LVL 2 OFGARAGE SLAB

T.O. PARAPET

T.O. PARAPET

T.O. PARAPET

6' -

11 1

/2"

22' -

0"

LVL B3-44' - 6"

SP LISTEDUSES

222 2nd Ave SNashville, TN

37201615.770.8100

Dra

wn

By:

Che

cked

By:

Appr

oved

By:

DATE:PROJECT:

G S & PR

G R E S H A MS M I T H A N DP A R T N E R S

Design ServicesFor The Built

Environment

LINE IS 3 INCHES WHEN PRINTED FULL SIZEFULL SHEET SIZE = 24"X36"

www.greshamsmith.com

PRELIMIN

ARY -

NOT FOR

CONSTRUCTION

12/2

1/20

17 1

0:33

:08

AMBI

M 3

60:/

/Cre

ed In

vest

men

ts/1

9255

09_C

het_

19th

_112

1_Ar

ch.rv

t

SECTIONS

A30742885.0012.12.2017

Auth

or

Chec

ker

Appr

over

19th

and

Che

tOf

fice

Tow

er82

7 19

TH A

VE

0' 48'32'16'8' 1/16" = 1'-0"1 NORTH / SOUTH SITE SECTION

RevisionNo. Date Description

Page 15: PRELIMINARY SP 19TH & CHET ATKINS - nashville.govmeasured from chet atkins place) w 3' r.o.w. dedication along 19th 4' r.o.w. dedication along (in place of 8' sidewalk & creed investments

LVL 10' - 0"

LVL B1-19' - 6"

LVL 220' - 0"

LVL 332' - 6"

LVL 445' - 0"

LVL 557' - 6"

LVL 670' - 0"

LVL 7 - AMENITY83' - 0"

LVL 898' - 0"

LVL 9113' - 0"

LVL 10128' - 0"

LVL 11143' - 0"

LVL 13173' - 0"

LVL 14188' - 0"

LVL 15203' - 0"

LVL 12158' - 0"

200' - 0" ROOF OF PENTHOUSE UNIT

70' - 0" ROOF OFAPARTMENTS

166' - 0" SITE DEPTH

60' WIDTH

40' STREETWIDTH

ALLEY WIDTH15' - 0"

ZONING SET BACK15' - 0"

LVL B2-32' - 0"

ELEVATOR PITS-52' - 0"

LVL 1 - 19TH CC-7' - 0"

LVL 1 - CHET CC2' - 0"

LVL 1 - CHET DOCK LEVEL4' - 0"

19' -

6"T.O. PARAPET

T.O. PARAPET

T.O. PARAPET

SP LISTEDUSES

8' -

6"

LVL B3-44' - 6"

SP LISTEDUSES

222 2nd Ave SNashville, TN

37201615.770.8100

Dra

wn

By:

Che

cked

By:

Appr

oved

By:

DATE:PROJECT:

G S & PR

G R E S H A MS M I T H A N DP A R T N E R S

Design ServicesFor The Built

Environment

LINE IS 3 INCHES WHEN PRINTED FULL SIZEFULL SHEET SIZE = 24"X36"

www.greshamsmith.com

PRELIMIN

ARY -

NOT FOR

CONSTRUCTION

12/2

1/20

17 1

0:33

:16

AMBI

M 3

60:/

/Cre

ed In

vest

men

ts/1

9255

09_C

het_

19th

_112

1_Ar

ch.rv

t

SECTIONS

A30842885.0012.12.2017

Auth

or

Chec

ker

Appr

over

19th

and

Che

tOf

fice

Tow

er82

7 19

TH A

VE

0' 48'32'16'8' 1/16" = 1'-0"1 EAST TO WEST SITE SECTION

RevisionNo. Date Description