Preparations for Installation
First all backup all router configurations on Laptop through FTP .
Step 1 Obtain the patch file matched with the version from Huawei.Step 2 Run the display version command on the router to confirm whether the version running on the device is
V300R006.
display version
Huawei Versatile Routing Platform Software
VRP (R) software, Version 5.60 (NE40E&80E V300R006C01SPC003)
Copyright (C) 2000-2009 Huawei Technologies Co., Ltd.
Quidway NetEngine 40E uptime is 5 days, 1 hour, 59 minutes
Step 3 Ensure that the file name of the patch to be uploaded does not exist on the router. After that, run thebinarycommand to upload NE40E80EV300R006C01SPC315.CC to the directory cfcard:/ of the routerthrough FTP in binary format through the ftp>binarycommand.
Step 4 If there is a standby MPU, copy the patch file to it by the command as follows: copy NE40E80EV300R006C01SPC315.CC slave#cfcard:/
Step 5 Before installing the new cold patch, please check whether there is any cold patch is already installed onthe router. If so, uninstall the installed cold patch.
Run the displaypacket-compatible command to check whether the same old patch is
already installed.
display packet-compatible
MainBoard:
Packet-Compatible: cfcard:/V300R006C01SPC301.CC
SlaveBoard:
Packet-Compatible: cfcard:/V300R006C01SPC301.CC
Run the following commands to uninstall the installed cold patch.
packet-compatible unload cfcard:/V300R006C01SPC301.CCCaution!!! This command may affect operation by wrong use, please carefully use
it with HUAWEI engineer's direction. Are you sure to do this operation ?[Y/N]?
y
Info: Succeeded in unloading the compatible packet.
packet-compatible unload cfcard:/V300R006C01SPC301.CC slave
Caution!!! This command may affect operation by wrong use, please carefully use
it with HUAWEI engineer's direction. Are you sure to do this operation ?[Y/N]?
y
Info: Succeeded in unloading the compatible packet.
Step 6 Before installing NE40E&80E V300R006C01SPC315, check whether the matching hot patch has beeninstalled. If not, install the hot patch first.
8/6/2019 Prepare Ti On for Cold Patched
2/2
NE40E&80E V300R006C01SPC315 can take effect only after NE40E&80EV300R006C01SPH015 or a hot patch of a later version is installed. To upgrade
NE40E&80E V300R006C01SPC315, you need to upgrade the hot patch first. For detailedprocedures of installing the hot patch, refer to the corresponding patch release notes.
If a hot patch earlier than NE40E&80E V300R006C01SPH015 has been installed, deletethe hot patch, and then install the hot patch matching NE40E&80E
V300R006C01SPC315.
----End