Upload
others
View
2
Download
0
Embed Size (px)
Citation preview
UCM Chemical Optosensors Group –Laboratory of Applied Photochemistry
Madrid, 13 Feb., 2007RED NAC. BIOSENSORES
The UCM Chemical Optosensors GroupThe UCM Chemical Optosensors Group––Laboratory of Applied PhotochemistryLaboratory of Applied Photochemistry
Prof. G. OrellanaProf. M. C. Moreno BondiProf. C. Pérez-CondeProf. Mª Dolores MarazuelaDr. F. NavarroDr. E. Benito-PeñaJavier UrracaSonia HerranzSilvia MateosSofia Martins
Prof. David GarcíaProf. Rocío CuervoDr. Sergio AbadDr. Laura TormoDavid HaighIrene IzquierdoFrancisco ManjónRuimán SantanaPilar CercósNuria Martín
Group Members Research topics
www.ucm.es/info/gsolfa
- Luminescent chemical (bio)sensors(environmental
monitoring, food &process analysis)
- MolecularlyImprinted
Polymers (MIPs)(SPE, chromatography,
Fluorescent based-MIAs)
- Luminescent probes(Indicators, dyes, (bio)molecular labeling)
- Singlet oxygen & applications(Solar water disinfection)
UCM Chemical Optosensors Group –Laboratory of Applied Photochemistry
Madrid, 13 Feb., 2007RED NAC. BIOSENSORES
Synthesis of molecular probes
Fiber-optic sensors
Characterization ofluminescent
indicators
Application andvalidation
The UCM Chemical Optosensors GroupThe UCM Chemical Optosensors Group––Laboratory of Applied PhotochemistryLaboratory of Applied Photochemistry
UCM Chemical Optosensors Group –Laboratory of Applied Photochemistry
Madrid, 13 Feb., 2007RED NAC. BIOSENSORES
Optical Optical ChemosensorsChemosensors and and ChemobiosensorsChemobiosensors
2O2
UCM Chemical Optosensors Group –Laboratory of Applied Photochemistry
Madrid, 13 Feb., 2007RED NAC. BIOSENSORES
UCM
NH4+, CO2,
detergents,hydrocarbons...
NH4+, CO2,
detergents,hydrocarbons...
2002
END USERS
2005
OPTOSENTM
www.interlab.es
The current measurand slate forenvironmental monitoring and process analysis
The current measurand slate forenvironmental monitoring and process analysis
O2TpH
BOD
RH
O2TpH
BOD
RH
UCM Chemical Optosensors Group –Laboratory of Applied Photochemistry
Madrid, 13 Feb., 2007RED NAC. BIOSENSORES
Monitoring ofriver watersMonitoring ofriver waters
time / days56 57 58 59 60 61 62
[O2]
/ mgL
-1
0
1
2
3
4
5
6
phas
e / º
-60
-50
-40
-30
-20optodeelectrodephase
Ru
Ru
kqτ0
+ hν’
+ 1O2
3O2
+ 3O2* Ru
hν
O2
Ru
RuRu
kqτ0
+ hν’
+ 1O2
3O2
+ 3O2* RuRu
hν
O2O2
UCM Chemical Optosensors Group –Laboratory of Applied Photochemistry
Madrid, 13 Feb., 2007RED NAC. BIOSENSORES
On-line BOD monitoring with OPTOSENTM at a WWTP inletOn-line BOD monitoring with OPTOSENTM at a WWTP inlet
t / daysjue 17 vie 18 sáb 19 dom 20 lun 21 mar 22 mié 23 jue 24
[DB
O] /
mg
L-1
0
200
400
600
800
1000
1200
1400
1600
1800
UCM Chemical Optosensors Group –Laboratory of Applied Photochemistry
Madrid, 13 Feb., 2007RED NAC. BIOSENSORES
Optosen®-DBO
UCM Chemical Optosensors Group –Laboratory of Applied Photochemistry
Madrid, 13 Feb., 2007RED NAC. BIOSENSORES
OPTOSEN-DBO®
Measurement range 1 - 10,000 mg L–1
Resolution max. 0.2 mg L–1
Response time ca. 20 minSample temp. range 0 to 60 ºCMaintenance solutions refill
every 30-60 days
OPTOSEN-DBO®
Measurement range 1 - 10,000 mg L–1
Resolution max. 0.2 mg L–1
Response time ca. 20 minSample temp. range 0 to 60 ºCMaintenance solutions refill
every 30-60 days
UCM Chemical Optosensors Group –Laboratory of Applied Photochemistry
Madrid, 13 Feb., 2007RED NAC. BIOSENSORES
Fluctuation analysis
Chlorophycea microalgae
Sensitive ResistantNO GMOs!
Microalgal biosensors for water quality measurementsMicroalgal biosensors for water quality measurements
time / s
0 2000 4000 6000 8000 10000 12000 14000 16000φ / º
30
32
34
36
38
40
42
44
46
48
501 min 1 min 3 min 2 min
time / s
0 2000 4000 6000 8000 10000 12000 14000 16000φ / º
30
32
34
36
38
40
42
44
46
48
501 min 1 min 3 min 2 min1 min 1 min 3 min 2 min
φ/ º
Response ofthe O2transducer
FUTURSEN
UCM Chemical Optosensors Group –Laboratory of Applied Photochemistry
Madrid, 13 Feb., 2007RED NAC. BIOSENSORES
“Polyfunctional Technical Textiles against Natural Hazards”
2006–2010 …
UCM Chemical Optosensors Group –Laboratory of Applied Photochemistry
Madrid, 13 Feb., 2007RED NAC. BIOSENSORES
2006–2009
Smart Maintenance of Aviation Hydraulic FluidUsing an On-board Monitoring and
Reconditioning System
UCM Chemical Optosensors Group –Laboratory of Applied Photochemistry
Madrid, 13 Feb., 2007RED NAC. BIOSENSORES
Funding sourcesFunding sources
• Spanish Ministry of Education & Science(AMB92-0092-C03, AMB95-0689-C02, AMB98-1043-C02, BQU2002-04515-CO2,
PROFIT, CTQ2006-15610-C02)
• Madrid Community Regional Government(07M/0082/2000, GR/MAT/00512004, S-0505/AMB/0374)
• Spanish Ministry of Education and Science(Doctoral grants)
• European Union (IV, V, VI FP)• Universidad Complutense de Madrid
• Spanish Ministry of Education & Science(AMB92-0092-C03, AMB95-0689-C02, AMB98-1043-C02, BQU2002-04515-CO2,
PROFIT, CTQ2006-15610-C02)
• Madrid Community Regional Government(07M/0082/2000, GR/MAT/00512004, S-0505/AMB/0374)
• Spanish Ministry of Education and Science(Doctoral grants)
• European Union (IV, V, VI FP)• Universidad Complutense de Madrid
www.ucm.es/info/gsolfa