Prezentare DMM Metrawatt

Embed Size (px)

Citation preview

  • 7/31/2019 Prezentare DMM Metrawatt

    1/26

  • 7/31/2019 Prezentare DMM Metrawatt

    2/26

    Dietmar Koops 31.10.2008 Page 2

    Multimeter TT

    Agenda

    News Training of Justification Application Hybrid Cars Flash Video

  • 7/31/2019 Prezentare DMM Metrawatt

    3/26

    Dietmar Koops 31.10.2008 Page 3

    Multimeter TT

    Display with the best contrast of the worldextreme high contrast with and without illumination andat low temperatures

    Revolutionary Cursor-fieldsimply use also in the menu functions

    DKD-calibration certificate in scope ofdeliveryworldwide biggest DKD laboratory

    ABS-plug protectionpatented shutter mechanism

    Auto-Range current measurementfrom 10nA up to 10A by one plug and one fuse

    Convincing quality and robustnessWater and dust protection IP65, Made in Germany

    The A and E-Series USPs

    A-Series 4 1 / 2 places ( 12.000 Counts) MultimeterE-Series 4 6 / 7 places ( 60.000 Counts) Multimeter

  • 7/31/2019 Prezentare DMM Metrawatt

    4/26

    Dietmar Koops 31.10.2008 Page 4

    Multimeter TT

    A-Series

    ABS

    12. 00012. 00012. 00012. 000COUNTS

    IR

    Resolution 4 1/2 places12.000 Counts

    Up to 26 measurements functions Accurancy VDC = 0,05%

    Memory (X-TRA) 512kBDatalogging >15.000 values

    Bandwidth V AC = 20kHz andIAC = 10kHz

  • 7/31/2019 Prezentare DMM Metrawatt

    5/26

    Dietmar Koops 31.10.2008 Page 5

    Multimeter TT

    E-Series

    Resolution 4 6/7 places60000 Counts

    Accurancy VDC = 0,05% Memory 2048kB Datalogging for>60.000 values

    dB measurement function System (IR-Interface) at ALLmodels

    Up to 33 measurement functions Bandwidth V AC = 50kHz und

    IAC = 10kHz

    ABS

    60. 00060. 00060. 00060. 000COUNTS

    IR

    Industry,Industry, service service organisations organisations ,, energy energy technology,technology,laboratories laboratories and and research research institutes institutes

  • 7/31/2019 Prezentare DMM Metrawatt

    6/26

    Dietmar Koops 31.10.2008 Page 6

    Multimeter TT

    S -Series

    MEMORY

    ABS

    12. 00012. 00012. 00012. 00030. 00030. 00030. 00030. 000COUNTS

    IR

    Special Multimeters for special applications and customers

    Picture

    Name / Model METRAHITOUTDOOR

    METRAHITISO

    SECULIFEHIT

    METRAHITT-COM

    METRAPORT40S

    Order Code M240O M246B M687A M246A M234G

    No. of Functions 27 30 27 33 24

    Resolution 12.000 30.0003.000

    12.000 3.000 30.000

    Accuracy (VDC) 0,05%+3D 0,15%+2D 0,05%+3D 0,5%+2D 0,2%+5DSpecials Water and

    Dust ProofIP65

    Insulationmeasurement

    Medical Appli-cations

    Insulationmeasurement,

    Loop Resis-tance, Length

    USB Port,Folding mechanism,

    AUTO Fuse

    l

  • 7/31/2019 Prezentare DMM Metrawatt

    7/26

    Dietmar Koops 31.10.2008 Page 7

    Multimeter TT

    Outdoor Multimeter

    Special rugged design Color sand Dustproof IP 6x Waterproof IP x5

    26 measurement functions likethe METRAHIT X-TRA

    MEMORY

    IP65

    ABS

    12. 00012. 00012. 00012. 000COUNTS

    Energy of offshore wind craft power plants should give us an important addition tofuture energy and climate politics. At the sea the fast wind speed has a hig potentialenergy. By the development of the offshore technologies of wind craft machines,which are now up to date at the land (onshore), we can use the potential energy. TheMETRAHIT OUTDOOR was special designed for use at this rugged weatherconditions. Wind, water, cold and hot climate cannot affect the instrument. Themultimeter is always ready for action.

  • 7/31/2019 Prezentare DMM Metrawatt

    8/26

    Dietmar Koops 31.10.2008 Page 8

    Multimeter TT

    The compact insolation testerand multimeter

    Insulation resistance measurementTest voltage: 1000V/500V/250V/100V/50V for

    insulation measurementsDisplay15mm large letters, illuminated with digital andanalog bar graph

    Multifunctional digital multimeter with TRMSVoltage V DC, VAC/DC ,VAC, resistance , capacitance,temperature F/ C , current I DC, IAC/DC , IAC, continuityand diode testing

    ReferencesCustomized version for SunTechnics , Miele, STILL

    Household appliance services (Miele, AEG, Bosch/Siemens),service of machines and forklifters (STILL, etc.)Photovoltaic (SunTechnics)

    METRAHIT | ISO

    Resolution and accurancy30000 counts, 4 places, 0.15% at voltage V DC

  • 7/31/2019 Prezentare DMM Metrawatt

    9/26

    Dietmar Koops 31.10.2008 Page 9

    Multimeter TT

    HIT ISO @ AVIONIC

    Tests and measurements at theAir Field Division (KLM)

    Hard Case - two coloured design,rugged and waterproof

    Cables, Connectors, Clamps andInstrument

    Insulation measurement fuel pump10V and 500V (Application at Boeing)

    Measuring of Voltage, Current,Resistance etc.

    Insolation measurement, tests of faultconditions

  • 7/31/2019 Prezentare DMM Metrawatt

    10/26

    Dietmar Koops 31.10.2008 Page 10

    Multimeter TT

    Process-Calibrator

    Comfortabel operating by the rotaryswitch, direct access buttons and acursor field

    Separated batterie case and fusecompartment

    Backlight illumination of the display

    Output can be switch on and off

    Multifunction display e.g.functions/value etc.

    METRA HIT | CAL

  • 7/31/2019 Prezentare DMM Metrawatt

    11/26Dietmar Koops 31.10.2008 Page 11

    Multimeter TT

    METRA HIT | CAL

    Resolution 30.000 Countse.g. 300.00mV, 24.000mA

    Accurancy 0.05%

    Simmulation of

    Voltage, Current Sink & Source,

    Frequency, Temperature(Thermocouple TC, Resistance RTD)

    Resistance

  • 7/31/2019 Prezentare DMM Metrawatt

    12/26Dietmar Koops 31.10.2008 Page 12

    Multimeter TT

    Display20mm big letters, extremly high contras also at lowtemperatures

    LCD-Backlightto work at bad conditions

    DKD-calibration certificate in scope of deliverylargest calibration laboratory of the world

    Folding mechanismOptimum adjustment of reading angle, protection inclosed condition

    Direct current measurementAuto-Range at lowes to highest range by one plug andprotectet by an resetable fuse

    Current clip measurementby the adjustable clip factor

    Resetable Fuse (AUTO Fuse)automatically switched in cas of mistake, no reparatur cost,immediately detection of the break and notice FUSE in thedisplay

    Made in Gemany

    Automotive-Multimeter Digital precision folding multimeter

    METRA PORT | 40S

    30. 00030. 00030. 00030. 000COUNTS

    Automotive Automotive industry industry and and workshops workshops ,,schools schools and and training training centers centers

  • 7/31/2019 Prezentare DMM Metrawatt

    13/26Dietmar Koops 31.10.2008 Page 13

    Multimeter TT

    The compact isolationmultimeter and cable tester

    METRAHIT | T-COM

    Multifunctional Digital Multimeter with TRMSVoltage V DC, VAC+DC , VAC, Current I DC, IAC+DC ,IAC Resistance ,Capacitance, Temperature F/ C , Continuity and Diode testing

    Display15mm big letters, excessively high contrast even at lowtemperatures (-20 C), LED illumination to work under bad lightconditions with analog bar graph (logarithmic @ TCOM)

    Insulation Resistance MeasurementMeasurement Voltage: 100V for telecommunication service

    Cable TesterCapacitance measurement, reversible polarity, connection of allconductors a, b and ground and switchover of measurementbetween conductors, loop resistant and length measurement

    DKD-Certificate in scope of deliverylargest DKD laboratory of the world

    Current MeasurementAuto-Range current measurement from lowest up to biggestrange over one plug and one fuse

    Current Clampssettable scaling factor for automatic conversation of the voltageoutput at the clamp to the measured current

    ReferencesCustomized version for Deutsche Telekom

    High quality and robustness, Made in Germany

  • 7/31/2019 Prezentare DMM Metrawatt

    14/26Dietmar Koops 31.10.2008 Page 14

    Multimeter TT

    Distributors Distributors ,, wholesalers wholesalers in in electrical electrical equipment equipment ( ( electricians electricians ,, students students ,, apprentices apprentices , etc.), etc.)

    METRAHIT | 2

    36/7 places multimeter ( 6.000 Counts) Voltage DC/AC 100 V..600V Current DC/AC 10 A..10A (16A 30sec) Resistance 0.1 ...40M Temperature - 50.0 C...+400 C TC-Type K Continuity and diode testing DC 3,000 V Data Hold, MIN/MAX value registration Auto Range ABS protection DKD calibration certificate Top Quality Made and Developed In Germany

    The best Price/Performance

  • 7/31/2019 Prezentare DMM Metrawatt

    15/26Dietmar Koops 31.10.2008 Page 15

    Multimeter TT

    Calibration vs Justification ?

    CALIBRATIONAt the calibration a measurement device will be tested and thedeviation (accurancy) to a standard (national or international) will bedetermined and documented/controlled.For example the deviation to the lenght standard in Paris (or thenational copies at the PTB, NPL, UKAS etc.).No other manipulation is done as the documentation. Target of thecalibration is a protocol, the so called calibration certificate.After the calibration it is not allowed to modify or justify the measuringdevice, otherwise the certificate become worthless. The calibrationonly can do the institute which has a standard of higher ranking thatmeans a known standard or measurement equipment which is

    qualified to record.

  • 7/31/2019 Prezentare DMM Metrawatt

    16/26Dietmar Koops 31.10.2008 Page 16

    Multimeter TT

    Calibration vs Justification ?

    JUSTIFICATIONFor justification the displayed value of a measuring device iscorrected, so the measured / indicated value (the so-called actualvalue) is set to the correct value, the so-called nominal value, as wellas possible.The target is to provide a correct value at the display.Anybody who is able to operate with the instrument can adjustify themeasurement device if the device allows it.An adjustment, for example to Zero, is often done before eachmeasurement. About deviations of measurements (set to actual value)says an adjustment, however, nothing. That is the subject ofcalibration.

    For maintanance of a device is done often both, adjustment andcalibration. Remember: After each adjustment is a previously donecalibration worthless, a re-calibration is therefore absolutelynecessary.

  • 7/31/2019 Prezentare DMM Metrawatt

    17/26Dietmar Koops 31.10.2008 Page 17

    Multimeter TT

    Hand Made Justification

    You can justify the measuring ranges of the following functions bymeans of MAN / AUTO and HOLD keys: AC voltage [V AC]

    DC voltage [V DC] Temperature Diode function

    Keep keys MAN / AUTO and HOLD depressed while inserting thebatteries.The justification mode is launched and CAL1 is shown at thedisplay.Connect the socket connectors of the measuring instrument with thecalibrator.

  • 7/31/2019 Prezentare DMM Metrawatt

    18/26Dietmar Koops 31.10.2008 Page 18

    Multimeter TT

    Justification of AC Voltage

    Justification of AC Voltage [V AC]

    Turn the rotary selector switch to V~.

    Set the calibrator to a value of 500 mV AC (50 Hz).

    Press the HOLD key in order to launch justification.

    CAL 1 is blinking in the display until justification is completed aftermax. 10 seconds. A double acoustic signal acknowledges successful

    justification. Set the calibrator to a value of 5 V AC (50 Hz).

    Press the MAN / AUTO key to switch from operating modeCAL1 to CAL2.

    Press the HOLD key in order to launch justification.

    CAL2 is blinking in the display until justification is completed after amaximum of 10 seconds. A double acoustic signal acknowledges

    successful justification .

  • 7/31/2019 Prezentare DMM Metrawatt

    19/26Dietmar Koops 31.10.2008 Page 19

    Multimeter TT

    Justification of DC Voltage

    Justification of DC Voltage [V DC]

    Turn the rotary selector switch to V =. Set the calibrator to a value of 5V DC.

    Press the HOLD key in order to launch justification.

    CAL is blinking in the display until justification is completed aftermax. 10 seconds. A double acoustic signal acknowledges successful justification.

  • 7/31/2019 Prezentare DMM Metrawatt

    20/26Dietmar Koops 31.10.2008 Page 20

    Multimeter TT

    Justification of Temperature 1

    There are three justification steps in the temperature functionbut first: Turn the rotary selector switch to C

    Short the inputs by a jumper Read the reference junction temperatur of the multimeter

    (ambient temperature)

    Set the calibrator in the temperature function (thermocouple type-K)with external reference and set this value.And now start the justification Set the calibrator to a value of 0 C Press the HOLD key in order to launch the first justification step.

    CAL 1 is blinking in the display until justification is completed after max.10 seconds. A double acoustic signal acknowledges successful

    justification

  • 7/31/2019 Prezentare DMM Metrawatt

    21/26Dietmar Koops 31.10.2008 Page 21

    Multimeter TT

    Justification of Temperature 2

    Next step Set the calibrator to a value of +350 C. Press the MAN / AUTO key to switch from operating mode

    CAL1 to CAL2. Press the HOLD key in order to launch the second justification step.

    CAL2 is blinking in the display until justification is completed after a

    maximum of 10 seconds. A double acoustic signal acknowledgessuccessful justification. Set the calibrator to a value of -40 C. Press the MAN / AUTO key to switch from operating mode

    CAL2 to CAL3. Press the HOLD key in order to launch justification.

  • 7/31/2019 Prezentare DMM Metrawatt

    22/26

  • 7/31/2019 Prezentare DMM Metrawatt

    23/26Dietmar Koops 31.10.2008 Page 23

    Multimeter TT

    Default values (factory settings)

    Error in justification ?

    Be carful by the new hand made justification. You canadjust the instrument to wrong values !!!!!You should calibrate the instrument, to fix and check thecorrect measurements !HELP:To re-establish the factory settings you can rebuild thedefauld values by pressing simultaneously the buttonsMAN/AUTOMAN/AUTO -- HOLDHOLD -- FUNCFUNC Keys and insert then the batteries

  • 7/31/2019 Prezentare DMM Metrawatt

    24/26Dietmar Koops 31.10.2008 Page 24

    Multimeter TT

    Calibration

    Turn the rotary selector switch to V =, etc.Connect the calibrator to the devicePress the MAN / AUTO key to Set the device in the 600mV Range

    Set the calibrator to a value of 0V DC.Write the correct value of the calibrator and the measured value ofthe device in a protocolSet the multimeter in the next Range 6VSet the next value on the calibrator e.g. 5V

    CalibrationCertificate

    CompanyGMC-I

    EquipmentMETRAHIT CAL

    Date07.11.2008

    Correct value Measured value Accuracy OK?

    0V 0,5% 5 = 0,5mV5V 0,5% 5 = 0,255V

    20V 0,5% 5 = 1,05V300V 0,5% 5 = 15,5V

  • 7/31/2019 Prezentare DMM Metrawatt

    25/26Dietmar Koops 31.10.2008 Page 25

    Multimeter TT

    Flash Movie for METRAHIT

    The animated Multimeter

    www.metrahit.de

    Flash Movie _Flash\index.html

  • 7/31/2019 Prezentare DMM Metrawatt

    26/26