Dietmar Koops 31.10.2008 Page 2
Multimeter TT
Agenda
News Training of Justification Application Hybrid Cars Flash Video
7/31/2019 Prezentare DMM Metrawatt
3/26
Dietmar Koops 31.10.2008 Page 3
Multimeter TT
Display with the best contrast of the worldextreme high contrast with and without illumination andat low temperatures
Revolutionary Cursor-fieldsimply use also in the menu functions
DKD-calibration certificate in scope ofdeliveryworldwide biggest DKD laboratory
ABS-plug protectionpatented shutter mechanism
Auto-Range current measurementfrom 10nA up to 10A by one plug and one fuse
Convincing quality and robustnessWater and dust protection IP65, Made in Germany
The A and E-Series USPs
A-Series 4 1 / 2 places ( 12.000 Counts) MultimeterE-Series 4 6 / 7 places ( 60.000 Counts) Multimeter
7/31/2019 Prezentare DMM Metrawatt
4/26
Dietmar Koops 31.10.2008 Page 4
Multimeter TT
A-Series
ABS
12. 00012. 00012. 00012. 000COUNTS
IR
Resolution 4 1/2 places12.000 Counts
Up to 26 measurements functions Accurancy VDC = 0,05%
Memory (X-TRA) 512kBDatalogging >15.000 values
Bandwidth V AC = 20kHz andIAC = 10kHz
7/31/2019 Prezentare DMM Metrawatt
5/26
Dietmar Koops 31.10.2008 Page 5
Multimeter TT
E-Series
Resolution 4 6/7 places60000 Counts
Accurancy VDC = 0,05% Memory 2048kB Datalogging for>60.000 values
dB measurement function System (IR-Interface) at ALLmodels
Up to 33 measurement functions Bandwidth V AC = 50kHz und
IAC = 10kHz
ABS
60. 00060. 00060. 00060. 000COUNTS
IR
Industry,Industry, service service organisations organisations ,, energy energy technology,technology,laboratories laboratories and and research research institutes institutes
7/31/2019 Prezentare DMM Metrawatt
6/26
Dietmar Koops 31.10.2008 Page 6
Multimeter TT
S -Series
MEMORY
ABS
12. 00012. 00012. 00012. 00030. 00030. 00030. 00030. 000COUNTS
IR
Special Multimeters for special applications and customers
Picture
Name / Model METRAHITOUTDOOR
METRAHITISO
SECULIFEHIT
METRAHITT-COM
METRAPORT40S
Order Code M240O M246B M687A M246A M234G
No. of Functions 27 30 27 33 24
Resolution 12.000 30.0003.000
12.000 3.000 30.000
Accuracy (VDC) 0,05%+3D 0,15%+2D 0,05%+3D 0,5%+2D 0,2%+5DSpecials Water and
Dust ProofIP65
Insulationmeasurement
Medical Appli-cations
Insulationmeasurement,
Loop Resis-tance, Length
USB Port,Folding mechanism,
AUTO Fuse
l
7/31/2019 Prezentare DMM Metrawatt
7/26
Dietmar Koops 31.10.2008 Page 7
Multimeter TT
Outdoor Multimeter
Special rugged design Color sand Dustproof IP 6x Waterproof IP x5
26 measurement functions likethe METRAHIT X-TRA
MEMORY
IP65
ABS
12. 00012. 00012. 00012. 000COUNTS
Energy of offshore wind craft power plants should give us an important addition tofuture energy and climate politics. At the sea the fast wind speed has a hig potentialenergy. By the development of the offshore technologies of wind craft machines,which are now up to date at the land (onshore), we can use the potential energy. TheMETRAHIT OUTDOOR was special designed for use at this rugged weatherconditions. Wind, water, cold and hot climate cannot affect the instrument. Themultimeter is always ready for action.
7/31/2019 Prezentare DMM Metrawatt
8/26
Dietmar Koops 31.10.2008 Page 8
Multimeter TT
The compact insolation testerand multimeter
Insulation resistance measurementTest voltage: 1000V/500V/250V/100V/50V for
insulation measurementsDisplay15mm large letters, illuminated with digital andanalog bar graph
Multifunctional digital multimeter with TRMSVoltage V DC, VAC/DC ,VAC, resistance , capacitance,temperature F/ C , current I DC, IAC/DC , IAC, continuityand diode testing
ReferencesCustomized version for SunTechnics , Miele, STILL
Household appliance services (Miele, AEG, Bosch/Siemens),service of machines and forklifters (STILL, etc.)Photovoltaic (SunTechnics)
METRAHIT | ISO
Resolution and accurancy30000 counts, 4 places, 0.15% at voltage V DC
7/31/2019 Prezentare DMM Metrawatt
9/26
Dietmar Koops 31.10.2008 Page 9
Multimeter TT
HIT ISO @ AVIONIC
Tests and measurements at theAir Field Division (KLM)
Hard Case - two coloured design,rugged and waterproof
Cables, Connectors, Clamps andInstrument
Insulation measurement fuel pump10V and 500V (Application at Boeing)
Measuring of Voltage, Current,Resistance etc.
Insolation measurement, tests of faultconditions
7/31/2019 Prezentare DMM Metrawatt
10/26
Dietmar Koops 31.10.2008 Page 10
Multimeter TT
Process-Calibrator
Comfortabel operating by the rotaryswitch, direct access buttons and acursor field
Separated batterie case and fusecompartment
Backlight illumination of the display
Output can be switch on and off
Multifunction display e.g.functions/value etc.
METRA HIT | CAL
7/31/2019 Prezentare DMM Metrawatt
11/26Dietmar Koops 31.10.2008 Page 11
Multimeter TT
METRA HIT | CAL
Resolution 30.000 Countse.g. 300.00mV, 24.000mA
Accurancy 0.05%
Simmulation of
Voltage, Current Sink & Source,
Frequency, Temperature(Thermocouple TC, Resistance RTD)
Resistance
7/31/2019 Prezentare DMM Metrawatt
12/26Dietmar Koops 31.10.2008 Page 12
Multimeter TT
Display20mm big letters, extremly high contras also at lowtemperatures
LCD-Backlightto work at bad conditions
DKD-calibration certificate in scope of deliverylargest calibration laboratory of the world
Folding mechanismOptimum adjustment of reading angle, protection inclosed condition
Direct current measurementAuto-Range at lowes to highest range by one plug andprotectet by an resetable fuse
Current clip measurementby the adjustable clip factor
Resetable Fuse (AUTO Fuse)automatically switched in cas of mistake, no reparatur cost,immediately detection of the break and notice FUSE in thedisplay
Made in Gemany
Automotive-Multimeter Digital precision folding multimeter
METRA PORT | 40S
30. 00030. 00030. 00030. 000COUNTS
Automotive Automotive industry industry and and workshops workshops ,,schools schools and and training training centers centers
7/31/2019 Prezentare DMM Metrawatt
13/26Dietmar Koops 31.10.2008 Page 13
Multimeter TT
The compact isolationmultimeter and cable tester
METRAHIT | T-COM
Multifunctional Digital Multimeter with TRMSVoltage V DC, VAC+DC , VAC, Current I DC, IAC+DC ,IAC Resistance ,Capacitance, Temperature F/ C , Continuity and Diode testing
Display15mm big letters, excessively high contrast even at lowtemperatures (-20 C), LED illumination to work under bad lightconditions with analog bar graph (logarithmic @ TCOM)
Insulation Resistance MeasurementMeasurement Voltage: 100V for telecommunication service
Cable TesterCapacitance measurement, reversible polarity, connection of allconductors a, b and ground and switchover of measurementbetween conductors, loop resistant and length measurement
DKD-Certificate in scope of deliverylargest DKD laboratory of the world
Current MeasurementAuto-Range current measurement from lowest up to biggestrange over one plug and one fuse
Current Clampssettable scaling factor for automatic conversation of the voltageoutput at the clamp to the measured current
ReferencesCustomized version for Deutsche Telekom
High quality and robustness, Made in Germany
7/31/2019 Prezentare DMM Metrawatt
14/26Dietmar Koops 31.10.2008 Page 14
Multimeter TT
Distributors Distributors ,, wholesalers wholesalers in in electrical electrical equipment equipment ( ( electricians electricians ,, students students ,, apprentices apprentices , etc.), etc.)
METRAHIT | 2
36/7 places multimeter ( 6.000 Counts) Voltage DC/AC 100 V..600V Current DC/AC 10 A..10A (16A 30sec) Resistance 0.1 ...40M Temperature - 50.0 C...+400 C TC-Type K Continuity and diode testing DC 3,000 V Data Hold, MIN/MAX value registration Auto Range ABS protection DKD calibration certificate Top Quality Made and Developed In Germany
The best Price/Performance
7/31/2019 Prezentare DMM Metrawatt
15/26Dietmar Koops 31.10.2008 Page 15
Multimeter TT
Calibration vs Justification ?
CALIBRATIONAt the calibration a measurement device will be tested and thedeviation (accurancy) to a standard (national or international) will bedetermined and documented/controlled.For example the deviation to the lenght standard in Paris (or thenational copies at the PTB, NPL, UKAS etc.).No other manipulation is done as the documentation. Target of thecalibration is a protocol, the so called calibration certificate.After the calibration it is not allowed to modify or justify the measuringdevice, otherwise the certificate become worthless. The calibrationonly can do the institute which has a standard of higher ranking thatmeans a known standard or measurement equipment which is
qualified to record.
7/31/2019 Prezentare DMM Metrawatt
16/26Dietmar Koops 31.10.2008 Page 16
Multimeter TT
Calibration vs Justification ?
JUSTIFICATIONFor justification the displayed value of a measuring device iscorrected, so the measured / indicated value (the so-called actualvalue) is set to the correct value, the so-called nominal value, as wellas possible.The target is to provide a correct value at the display.Anybody who is able to operate with the instrument can adjustify themeasurement device if the device allows it.An adjustment, for example to Zero, is often done before eachmeasurement. About deviations of measurements (set to actual value)says an adjustment, however, nothing. That is the subject ofcalibration.
For maintanance of a device is done often both, adjustment andcalibration. Remember: After each adjustment is a previously donecalibration worthless, a re-calibration is therefore absolutelynecessary.
7/31/2019 Prezentare DMM Metrawatt
17/26Dietmar Koops 31.10.2008 Page 17
Multimeter TT
Hand Made Justification
You can justify the measuring ranges of the following functions bymeans of MAN / AUTO and HOLD keys: AC voltage [V AC]
DC voltage [V DC] Temperature Diode function
Keep keys MAN / AUTO and HOLD depressed while inserting thebatteries.The justification mode is launched and CAL1 is shown at thedisplay.Connect the socket connectors of the measuring instrument with thecalibrator.
7/31/2019 Prezentare DMM Metrawatt
18/26Dietmar Koops 31.10.2008 Page 18
Multimeter TT
Justification of AC Voltage
Justification of AC Voltage [V AC]
Turn the rotary selector switch to V~.
Set the calibrator to a value of 500 mV AC (50 Hz).
Press the HOLD key in order to launch justification.
CAL 1 is blinking in the display until justification is completed aftermax. 10 seconds. A double acoustic signal acknowledges successful
justification. Set the calibrator to a value of 5 V AC (50 Hz).
Press the MAN / AUTO key to switch from operating modeCAL1 to CAL2.
Press the HOLD key in order to launch justification.
CAL2 is blinking in the display until justification is completed after amaximum of 10 seconds. A double acoustic signal acknowledges
successful justification .
7/31/2019 Prezentare DMM Metrawatt
19/26Dietmar Koops 31.10.2008 Page 19
Multimeter TT
Justification of DC Voltage
Justification of DC Voltage [V DC]
Turn the rotary selector switch to V =. Set the calibrator to a value of 5V DC.
Press the HOLD key in order to launch justification.
CAL is blinking in the display until justification is completed aftermax. 10 seconds. A double acoustic signal acknowledges successful justification.
7/31/2019 Prezentare DMM Metrawatt
20/26Dietmar Koops 31.10.2008 Page 20
Multimeter TT
Justification of Temperature 1
There are three justification steps in the temperature functionbut first: Turn the rotary selector switch to C
Short the inputs by a jumper Read the reference junction temperatur of the multimeter
(ambient temperature)
Set the calibrator in the temperature function (thermocouple type-K)with external reference and set this value.And now start the justification Set the calibrator to a value of 0 C Press the HOLD key in order to launch the first justification step.
CAL 1 is blinking in the display until justification is completed after max.10 seconds. A double acoustic signal acknowledges successful
justification
7/31/2019 Prezentare DMM Metrawatt
21/26Dietmar Koops 31.10.2008 Page 21
Multimeter TT
Justification of Temperature 2
Next step Set the calibrator to a value of +350 C. Press the MAN / AUTO key to switch from operating mode
CAL1 to CAL2. Press the HOLD key in order to launch the second justification step.
CAL2 is blinking in the display until justification is completed after a
maximum of 10 seconds. A double acoustic signal acknowledgessuccessful justification. Set the calibrator to a value of -40 C. Press the MAN / AUTO key to switch from operating mode
CAL2 to CAL3. Press the HOLD key in order to launch justification.
7/31/2019 Prezentare DMM Metrawatt
22/26
7/31/2019 Prezentare DMM Metrawatt
23/26Dietmar Koops 31.10.2008 Page 23
Multimeter TT
Default values (factory settings)
Error in justification ?
Be carful by the new hand made justification. You canadjust the instrument to wrong values !!!!!You should calibrate the instrument, to fix and check thecorrect measurements !HELP:To re-establish the factory settings you can rebuild thedefauld values by pressing simultaneously the buttonsMAN/AUTOMAN/AUTO -- HOLDHOLD -- FUNCFUNC Keys and insert then the batteries
7/31/2019 Prezentare DMM Metrawatt
24/26Dietmar Koops 31.10.2008 Page 24
Multimeter TT
Calibration
Turn the rotary selector switch to V =, etc.Connect the calibrator to the devicePress the MAN / AUTO key to Set the device in the 600mV Range
Set the calibrator to a value of 0V DC.Write the correct value of the calibrator and the measured value ofthe device in a protocolSet the multimeter in the next Range 6VSet the next value on the calibrator e.g. 5V
CalibrationCertificate
CompanyGMC-I
EquipmentMETRAHIT CAL
Date07.11.2008
Correct value Measured value Accuracy OK?
0V 0,5% 5 = 0,5mV5V 0,5% 5 = 0,255V
20V 0,5% 5 = 1,05V300V 0,5% 5 = 15,5V
7/31/2019 Prezentare DMM Metrawatt
25/26Dietmar Koops 31.10.2008 Page 25
Multimeter TT
Flash Movie for METRAHIT
The animated Multimeter
www.metrahit.de
Flash Movie _Flash\index.html