133
Pricelist 2021-2022 Applied Systems Prices and technical information for Applied Systems

Pricelist 2021-2022 Applied Systems

  • Upload
    others

  • View
    7

  • Download
    0

Embed Size (px)

Citation preview

Pricelist 2021-2022

Applied Systems

Prices and technical information for Applied Systems

2

This is not a showroom.

This is the augmented reality powered, never before experienced,

experts-driven Your Daikin World.

Discover Daikin’s full range of industry-leading innovative climate solutions like nowhere else.

Experience product demonstrations powered by augmented reality, co-create state-of-the-art

climate solutions and connect with experts for professional customized consultation.

This is Your Daikin World. Let’s get in touch.

Applied Systems Price list 2021-2022 3

This is nota workshop.This is the expert driven,state-of-the-art co-creation sessionat Your Daikin World.

Progress happens where passion meets expertise. Join Daikin experts in custom-tailored, full-lifecycle training sessions, co-create unique solutions for your business and elevate it – like nowhere else.

This is Your Daikin World. Let’s get in touch.

Daikin Central EuropeLemböckgasse 59/1/1, 1230 Vienna, Austria

www.yourdaikinworld.com

4

Type Refrigerant Compressor Material Capacity Page

Key information - Ecodesign directive and Energy Labelling

6

All in One 7

Air cooled chillersAir cooled mini inverter chiller R-410A Swing EWAQ-A & EWAQ-B 4-13 kW 10

Air cooled mini inverter heat pump R-410A Swing EWYQ-A & EWYQ-B 4-13 kW 11

Air cooled mini inverter chiller R-32 Scroll EWAA-DV3P/DW1P 11-16 kW 12

Air cooled mini inverter heat pump R-32 Scroll EWYA-DV3P/DW1P 9-16 kW 13

Air cooled scroll inverter chiller R-410A Scroll EWAQ-CW 17-64 kW 15

Air cooled scroll inverter heat pump R-410A Scroll EWYQ-CW 17-64 kW 16

Air cooled scroll inverter heat pump - split version R-410A Scroll SEHVX-BW & SER-HQ-BW1

20-64 kW 17

Hydronic connection examples 18

EWYT-B Multi scroll Air heat pump with R-32 refrigerant

20

Air cooled Chiller - standard efficiency - standard noise R-32 Scroll EWYT-B-SS 85-215 kW 21

Air cooled Chiller - standard efficiency - low noise R-32 Scroll EWYT-B-SL 85-215 kW 23

Air cooled Chiller - standard efficiency - reduced noise R-32 Scroll EWYT-B-SR 85-215 kW 25

Air cooled Chiller - High efficiency - standard noise R-32 Scroll EWYT-B-XS 85-215 kW 27

Air cooled Chiller - High efficiency - low noise R-32 Scroll EWYT-B-XL 85-215 kW 29

Air cooled Chiller - High efficiency - reduced noise R-32 Scroll EWYT-B-XR 85-215 kW 31

EWAT-B- Multi scroll Air cooled chiller range with R-32 refrigerant

33

Air cooled Chiller - standard efficiency - standard noise R-32 Scroll EWAT-B-SS 85-205 kW 34

Air cooled Chiller - standard efficiency - low noise R-32 Scroll EWAT-B-SL 85-205 kW 36

Air cooled Chiller - standard efficiency - reduced noise R-32 Scroll EWAT-B-SR 85-205 kW 38

Air cooled Chiller - high efficiency - standard noise R-32 Scroll EWAT-B-XS 85-200 kW 40

Air cooled Chiller - high efficiency - low noise R-32 Scroll EWAT-B-XL 85-200 kW 42

Air cooled Chiller - high efficiency - reduced noise R-32 Scroll EWAT-B-XR 85-200 kW 44

Water cooled chillersWater cooled chiller R-410A Scroll EWWQ-KBW1N 14-64 kW 46

Water cooled chiller R-410A Scroll EWWQ-KBW1M 98-192 kW 47

Product description - water cooled chiller EWW(H)Q-G(L)-SS 48

Water cooled chiller - standard efficiency -

standard noise - one refrigerant circuit R-410A Scroll EWWQ-G-SS 90-360 kW 49

Water cooled heat pump - standard efficiency R-410A Scroll EWHQ-G-SS 100-400 kW 50

Water cooled chiller - standard efficiency -

standard noise - two refrigerant circuits R-410A Scroll EWWQ-L-SS 180-330 kW 51

Condenserless chillersCondenserless chiller R-410A Scroll EWLQ-KBW1N 14-64 kW 52

Condenserless chiller - standard efficiency -

standard noise - one refrigerant circuit R-410A Scroll EWLQ-G-SS 90-360 kW 53

Condenserless chiller - standard efficiency -

standard noise - two refrigerant circuits R-410A Scroll EWLQ-L-SS 180-330 kw 54

intelligent Chiller Manager - iCM 55

Microtech® 4 58

Microtech® 4 - intelligent Chiller manager 59

NEW

NEWNEW

NEW

Table of contents

Applied Systems Price list 2021-2022 5

NOTE:All prices are list prices, excl. VAT and valid from 1 April 2021 till 31. March 2022. All prior pricelists are not valid anymore. The Daikin Commercial Terms and Conditions apply (see

last page or www.daikin.sk/VOP). We reserve the right for printing errors and model changes. The LOT1&2 regulation requires the manufacturers to publish additional energy

efficiency data for some products shown in this literature. From September 2015, these required efficiency data can be publicly viewed and downloaded from the following free

access website: https://www.daikin-ce.com/seasonal-efficiency

Type Refrigerant Compressor Material Capacity Page

Fan coil Low ESP duct FWE-D 3-11 kW 62

Low ESP duct FWE-C 2 - 10 kW 64

Medium ESP duct FWB-B 2- 10 kW 65

Medium ESP duct / BLDC FWP-A 2 – 7 kW 67

Medium ESP duct / BLDC FWN-A 4 - 10 kW 68

High ESP flexi duct FWD-A 4 - 18 kW 70

Wall mounted FWT-G 2 - 6 kW 72

Cassette 600x600 FWF-B 2 - 5 kW 73

Cassette 900x900 FWC-B 6- 9 kW 73

Floor standing FWV-D 1 - 10 kW 76

Flexi type FWL-D 1 - 10 kW 77

Flexi concealed FWM-D 1 - 10 kW 78

Floor standing / BLDC FWZ-A 2 - 8 kW 83

Flexi type / BLDC FWR-A 2 - 8 kW 84

Flexi concealed / BLDC FWS-A 2 - 8 kW 85

Air Handling Units - AHU 89Modular Light / Smart ALB-R/LB(S) 100 - 3.400 m³/h 91

Electrical heater for Modular L Smart ALD-HEFB 1,5-15 kW 93

Modular P Package Modular P 1.100-12.500 m³/h 95

Modular R Package Modular R 1.600-19.200 m³/h 96

Condensing unit heat pump Inverter R-410A Scroll ERQ 11-28 kW 97

Daikin Rooftops 98Rooftop R-32 Scroll UATYA-BBAY1 25-190 kW 108

Rooftop R-32 Scroll UATYA-BFC2Y1 25-190 kW 108

Rooftop R-32 Scroll UATYA-BFC3Y1 25-190 kW 109

Active chilled beams 110

Overview: Air cooled and condensing unit portofolio 116

Overview: Water cooled and condenserless unit portfolio 118

Total solution productsAir Cooler, Air Handling Unit, Dry Cooler & Condenser

Cooling Tower, Compressor Service 120

Measuring conditions 121

Daikin Service Portfolio 122Remote Monitoring 122

Active Monitoring with Daikin on Site 124

Energy Audit (on-site) Chillers 128Commercial terms and conditions 130

NEW

NEWNEW

NEW

NEW

6

Ecodesign Directive and Energy LabelsThe Ecodesign Directive defines the minimum standards for the environmental characteristics of heaters, water heaters and combi appliances. From 26 September 2015, heat generators of up to 70 kW output and tanks of up to 500 litres must be marked with a label showing their energy efficiency. This applies to all individual products (product label) and heating systems (package label) brought onto the market from this date. In addition, a product datasheet containing detailed information must be made available for each item.

From green to redThe principle is well-known from refrigerators, washing machines and TV sets: Devices and appliances are split into efficiency classes on a scale from A+++ to G. Dark green represents the highest level of efficiency, dark red the lowest. The scales differ between the individual product groups.

Identical across EuropeThe Ecodesign Directive for heat generators and water heaters, and the obligation to identify products and system solutions with energy labels, will apply to all member states of the European Union. The aim is to promote the manufacture and development of more environmentally responsible and energy efficient heating systems and to simplify comparisons for consumers.

Heat generators

2015

2019

Water heaters Packages

2015

2017

2015

Key Information

Applied systems: products in scope Since 2013, all air conditioners and air-to-air heat pumps under 12 kW are in scope of this Eco-Design directive.

Since 26 September 2015, heat generators for space heating (LOT 1) also need to comply to these 20-20-20 targets. For the applied systems market it means that all heat pumps below 400 kW need to comply to minimum efficiency requirements. Heat pumps below 70 kW must be marked with a product energy label.

Since 26 September 2017, second tier of LOT 1 came into force, requiring minimum seasonal efficiency (SCOP) for the air to water & water to water heat pumps up to 400 kW.

Since 2018, the Ecodesign Directive sees ENER LOT 21 came into force to increase energy efficiency and reduce carbon emissions throughout Europe. The products in scope are: ʯ Air conditioners - all air conditioners over 12 kW, with specific requirements for both cooling and heating.

ʯ Cooling only chillers up to 1.500kW. ʯ Reversible chillers from 400 kW to 1.500kW (reversible chillers up to and including 400kW are excluded from the regulation as being covered by directive (EC) 813/2013 with regard to Ecodesign requirements for space heaters and combination heaters).

ʯ Heating only chillers are excluded from the LOT 21, with no minimum heating requirements specified.

Since 2021, second tier of ENER LOT 21 came into force, increasing the efficiency thresholds for the product categories mentioned above within LOT 21 first tier (2018).

Our service Daikin helps its partners to meet their obligations regarding the Ecodesign Directive and energy labelling. Labels, product and technical fiches for each individual product are available as downloads at any time from the Energy Label Generator at https://www.daikin.eu/en_us/about/daikin-innovations/seasonal-efficiency.html

Applied Systems Price list 2021-2022 7

Turnkey Delivery by Daikin: “All in ONE”

Let Daikin handle all for you

Next to its comprehensive product range, Daikin now offers turnkey project delivery, which

we call ‘All in ONE’, where various type of applications are carried out directly by Daikin,

including installation.

The offering contains following main steps and is shaped according to customer needs:

You can enjoy the benefits of this service for any kind of HVAC-R applications, regardless if it is

a new build or a replacement.

DESIGN Creation of the concept / solution that will meet customer’s wishes in

the best way

COMMISSION Commissioning of

whole HVAC-R system (incl. non-Daikin equipment)

OFFER Preparation of the offer in which complete HVAC-R product and

service needs are covered

MONITOR Remote Monitoring

of the site for optimization and remote control

INSTALL Along with the certified partner,

execution of site works for complete HVAC-R project scope

SUPPORT Troubleshooting

and maintenance of the site via certified HVAC-R partner

All in One

8

Generate win-win solutions with “All in ONE”

All in ONE approach aims to generate win-win solutions by offering for both its service

partners and key accounts significant benefits. While our Key Accounts enjoy the advantages

of the direct approach, our partners grow with us via projects granted by Daikin.

Steady business

Daikin executes turn key projects with its certified partners therefore, guarantees a steady business to them.

Growth

Daikin makes regional agreements with new Investors and Key Accounts which returns as pure growth to its partners.

Reduced liability & effort

Daikin owns technical and financial liability which limits the partner’s risk exposure.

Reputation

Major winning chance in reference projects therefore, helps to build the reputation you need.

Single point of contact

Your Daikin contact will serve for all project needs within same approach for all Central Europe (CE). Daikin also holds liability for the complete HVAC-R.

Saving

Daikin can serve more efficiently with a larger scale contract therefore, offers great saving potential.

One stop shop

Daikin offers product and solutions for complete project scope and also can create ‘concepts’ per customer wishes.

Quality

Daikin extends its product quality principles to the execution of your project by fully dedicated central and local project teams.

What does this mean for our partners?

What does this mean for our Key Accounts?

All in One

9

Client: VMD GrupaSolution: VRV Heat pump & control 57 VRV IV heat pumps, 685 ceiling cassettes, 2 intelligent Touch Manager unitsYear of installation: 2014/2015Total capacity: 2.400 kW

Key benefits: › Design supported by Daikin › Daikin site supervision › One service contract › Single point of contact › High reliability

Start of Energy-Saving Control: January 2019 Expected reducing of power consumption 15-20%Control overview: Reducing of power consumption with no effecton the indoor temperature and comfort.Control results: Predictive and proactive maintenance, remotesupport

Client: International Property Development, s.r.oSolution: VRV Heat pump

Key benefits: › Design supported by Daikin › Guarantee of completion › Lower overall risk due to the size of the project

› Project management by Daikin › Rapid reaction to design changes

Start of Energy-Saving Control: January 2019Control overview: Besides the proven and reliable VRV systems, the cloud service especially its predictive error notification feature is an integral part of the solution.This feature ensures, that the service organisation is immediately notified not only about the occurred error, but also about the potential problems that may occur in the near future.This allows the service organisation to react quickly and shorten the time

VMD Business Centre Tower B, Zagreb, Croatia

Einsteinova Business Center, Bratislava, Slovakia

All in One

Daikin “All in ONE” References

needed to solve potential problems.As this building is not only cooled by VRV, but also heated, this feature is particularly important.

10

EWAQ-B ʯ Inverter controlled swing compressors with refrigerant R-410A ʯ High SEER thanks to inverter technology, integrated hydronics. ʯ Application range cooling air side + 10°C to + 43°C ʯ Application range cooling water side + 5°C to + 20°C ʯ Built-in Hydraulic kit: no buffer tank required, standard inverter driven pump, main flow sensor and switch included.

ʯ Expansion vessel included ʯ Control panel included

Air cooled mini inverter chiller

Unit size (1 phase) EWAQ 004BVP 005BVP 006BVP 008BVPPrice(1) € 2.884,- 3.142,- 3.369,- 3.722,-Cooling capacity(2) kW 4,00 4,93 5,88 7,95EER 3,14 3,06 3,15 3,10SEER 4,38 4,39 4,42 4,53Sound power level dB(A) 63,0 64,2 69 69Supply voltage (1-phase) V~ 230

Options

OP10Evaporator heater tape including better insulation of the hydraulic

€ 365,- 361,-

EKCB07CV3 (4) Control box for remote control € 316,-

EKRUMCL1 Remote user interface (additional) € 128,-

EKRSC1 (11) Decentralized outside temperature sensor

110,-

EKPCCAB4 (12) PC cable kit € 362,-

EKBPH140L (13) Bottom plate heater € 145,-EK2CB07CV3 (5)

Option box, requires EKCB07CV3 € 316,-

EKMBUHC3V3 (7) (8) (9) Backup heater kit € 811,-

EKMBUHC9W1 (7) (8) (9) (10) Backup heater kit € 764,-

EKRTWA Wireless room thermostat € 169,-

EKRTRWireless room thermostat, 230 V, receiver included

€ 330,-

EKRTETS (6) External temperature sensor option kit € 21,-

KRCS01-1 (11) Remote sensor for indoor € 95,-

EKMBHBP (8) (9) Valve kit € 218,-

Notes:

(1) Pump integrated; (2) Cooling: Ta DB/WB 35°C - LWE 7°C ( DT = 5°C) data according EN 14511: 2011;

(3) According to Eurovent web site: https://www.eurovent-certification.com/enclose/

(4) Control box EKCB07CV3 is needed to use these options: bacup heater, external room thermostat/heat pump convector, option box, electricity meter, power limitation digital

inputs.

(5) Option box EK2CB07CV3 is needed to use these options: control external heat source(bivalent operation), output remote ON/OFF signal space heating/cooling, remote alarm output,

external indoor thermistor.

(6) EKRTETS can only be used in combination with EKRTR.

(7) Only one of these options can be installed per indoor unit.

(8) Only for reversible model.

(9) If condensation is expected, the installation of the valve kit EKMBHBP is required.

(10) Unified model, the actual backup heater capacity depends on the actual internal upwiring. For the model description, please refer to the databook.

(11) Only one sensor connectable: indoor or outdoor.

(12) Data cable for connection with PC.

(13) In case of high humidity conditions (relative humidity >92%; outdoor ambient temperature <-5°C), an optional bottom plate heater is required to avoid freeze-up of the outdoor unit.

Applied Systems Price list 2021-2022 11

EWYQ-B ʯ Inverter controlled swing compressors with refrigerant R-410A ʯ High SEER thanks to inverter technology ʯ Application range cooling air side +10°C to +43°C ʯ Application range cooling water side +5°C to +22°C ʯ Application range heating air side -20°C to +25°C ʯ Application range heating water side +15°C to +55°C ʯ Built-in Hydraulic kit: no buffer tank required, standard inverter driven pump, main flow sensor and switch included.

ʯ Expansion vessel included ʯ Control panel included

Air cooled mini inverter heat pump

Notes:

(1) Pump integrated; (2) Cooling: Ta DB/WB 35°C - LWE 7°C ( DT = 5°C) data according EN 14511: 2011 ; (3) Heating: Ta DB/WB 7°C/6°C - LWC 45°C (Dt=5°C), data according EN 14511: 2011;

(4) According to Eurovent web site: https://www.eurovent-certification.com/enclose/

(5) Control box EKCB07CV3 is needed to use these options: bacup heater, external room thermostat/heat pump convector, option box, electricity meter, power limitation digital

inputs.

(6) Option box EK2CB07CV3 is needed to use these options: control external heat source(bivalent operation), output remote ON/OFF signal space heating/cooling, remote alarm

output, external indoor thermistor.

(7) EKRTETS can only be used in combination with EKRTR.

(8) Only one of these options can be installed per indoor unit.

(9) Only for reversible model.

(10) If condensation is expected, the installation of the valve kit EKMBHBP is required.

(11) Unified model, the actual backup heater capacity depends on the actual internal upwiring. For the model description, please refer to the databook.

(12) Only one sensor connectable: indoor or outdoor.

(13) Data cable for connection with PC.

(14) In case of high humidity conditions (relative humidity >92%; outdoor ambient temperature <-5°C), an optional bottom plate heater is required to avoid freeze-up of the

outdoor unit.

Unit size (1 phase) EWYQ 004BVP 005BVP 006BVP 008BVPPrice(1) € 3.206,- 3.492,- 3.743,- 4.137,-Cooling capacity(2) kW 4,00 4,93 5,88 7,95EER 3,14 3,06 3,15 3,10SEER(4) 4,38 4,39 4,42 4,53Heating capacity(3) kW 4,11 4,99 6,14 8,08COP 3,44 3,41 3,51 3,49Space heating Average

climate water outlet 55°C

ηs (Seasonal space heating efficiency) % 114 118 124 124

SCOP 2,92 3,01 3,19 3,17

Seasonal space heating eff. class A+ A+ A+ A+

Sound power level dB(A) 63 64 69 69Supply voltage (1-phase) V~ 230

Options

OP10Evaporator heater tape including better insulation of the hydraulic

€ 365,- 361,-

EKCB07CV3 (5) Control box for remote control € 316,-

EKRUMCL1 Remote user interface (additional) € 128,-

EKRSC1 (12) Decentralized outside temperature sensor

€ 110,-

EKPCCAB4 (13) PC cable kit € 362,-

EKBPH140L (14) Bottom plate heater € 145,-EK2CB07CV3 (6)

Option box, requires EKCB07CV3 € 316,-

EKMBUHC3V3 (8) (9) (10) Backup heater kit € 811,-

EKMBUHC9W1 (8) (9) (10) (11) Backup heater kit € 764,-

EKRTWA Wireless room thermostat € 169,-

EKRTRWireless room thermostat, 230 V, receiver included

€ 330,-

EKRTETS (7) External temperature sensor option kit € 21,-

KRCS01-1 (12) Remote sensor for indoor € 95,-

EKMBHBP (9) (10) Valve kit € 218,-

12

EWAA-DV3P/DW1P ʯ Inverter controlled swing compressor with refrigerant R-32 ʯ R-32 refrigerant: reduced environmental impact and 30% less refrigerant charge needed

ʯ Application range cooling air side + 10°C to + 43°C ʯ Application range cooling water side + 5°C to + 22°C ʯ Compact design with built-in hydraulic kit: no buffer tank required, standard inverter driven pump, expansion vessel, main flow sensor and switch included

ʯ Easy installation and maintenance ʯ Separate MMI-2 controller for indoor installation

EWAA-DV3P-H/DW1P-H- ʯ Inverter controlled swing compressor with refrigerant R-32 ʯ R-32 refrigerant: reduced environmental impact and 30% less refrigerant charge needed

ʯ Application range cooling air side + 10°C to + 43°C ʯ Application range cooling water side + 5°C to + 22°C ʯ Compact design with built-in hydraulic kit: no buffer tank required, standard inverter driven pump, expansion vessel, main flow sensor included

ʯ Easy installation and maintenance ʯ Separate MMI-2 controller for indoor installation ʯ Water piping heater tape (OP10) as standard for a better insulation of the hydraulic

Air cooled mini inverter chiller

Cooling Only EWAA 011DV3P 014DV3P 016DV3P 011DW1P 014DW1P 016DW1P Single phase Three phases

Price € 5.031,- 5.391,- 5.778,- 5.132,- 5.500,- 5.893,-Cooling capacity Nom. kW 11,6(1) / 11,5(2) 12,8(1) / 12,7(2) 14,0(1) / 15,3(2) 11,6(1) / 11,5(2) 12,8(1) / 12,7(2) 14,0(1) / 15,3(2)

Power input Cooling Nom. kW 3,56(1) / 2,17(2) 4,06(1) / 2,51(2) 4,58(1) / 3,24(2) 3,56(1) / 2,17(2) 4,06(1) / 2,51(2) 4,58(1) / 3,24(2)

SEER(3) 5,79 5,71 5,59 5,79 5,71 5,59Space cooling ηs,c % 229 226 221 229 226 221EER 3,26(1) / 5,31(2) 3,16(1) / 5,04(2) 3,06(1) / 4,74(2) 3,26(1) / 5,31(2) 3,16(1) / 5,04(2) 3,06(1)/ 4,74(2)

Refrigerant Circuits Quantity 1Compressor Quantity 1Dimensions Unit Depth x Width x Height mm 460 x 1.380 x 870Weight Unit / Operation weight kg 147Sound power level / Sound pressure level

Cooling Nom. dBA 67,0 / 47,7 69,0 / 50,8 69,0 / 51,0 67,0 / 47,7 69,0 / 50,8 69,0 / 51,0

Power supply Phase / Frequency / Voltage Hz / V 1~ / 50 / 230 3~ / 50 / 400

Cooling Only EWAA(4) 011DV3P-H- 014DV3P-H- 016DV3P-H- 011DW1P-H- 014DW1P-H- 016DW1P-H- Single phase Three phases

Price € 5.770,- 6.132,- 6.519,- 5.873,- 6.241,- 6.633,-Cooling capacity Nom. kW 11,6(1) / 11,5(2) 12,8(1) / 12,7(2) 14,0(1) / 15,3(2) 11,6(1) / 11,5(2) 12,8(1) / 12,7(2) 14,0(1) / 15,3(2)

Power input Cooling Nom. kW 3,56(1) / 2,17(2) 4,06(1) / 2,51(2) 4,58(1) / 3,24(2) 3,56(1) / 2,17(2) 4,06(1) / 2,51(2) 4,58(1) / 3,24(2)

SEER(3) 5,79 5,71 5,59 5,79 5,71 5,59Space cooling ηs,c % 229 226 221 229 226 221EER 3,26(1) / 5,31(2) 3,16(1) / 5,04(2) 3,06(1) / 4,74(2) 3,26(1) / 5,31(2) 3,16(1) / 5,04(2) 3,06(1) / 4,74(2)

Refrigerant Circuits Quantity 1Compressor Quantity 1Dimensions Unit Depth x Width x Height mm 460 x 1.380 x 870Weight Unit / Operation weight kg 147Sound power level / Sound pressure level

Cooling Nom. dBA 67,0 / 47,7 69,0 / 50,8 69,0 / 51,0 67,0 / 47,7 69,0 / 50,8 69,0 / 51,0

Power supply Phase / Frequency / Voltage Hz / V 1~ / 50 / 230 3~ / 50 / 400

(1) Cooling: EW 12°C; LW 7°C; ambient conditions: 35°CDB(2) Cooling: EW 23°C; LW 18°C; ambient conditions: 35°CDB (3) According to EN14825

(1) Cooling: EW 12°C; LW 7°C; ambient conditions: 35°CDB(2) Cooling: EW 23°C; LW 18°C; ambient conditions: 35°CDB (3) According to EN14825 (4) EWAA-D(VP3/W1P)-H- has water piping heater tape (OP10) as standard

Applied Systems Price list 2021-2022 13

EWYA-DV3P/DW1P ʯ Inverter controlled swing compressor with refrigerant R-32 ʯ R-32 refrigerant: reduced environmental impact and 30% less refrigerant charge needed

ʯ Application range cooling air side + 10°C to + 43°C ʯ Application range cooling water side + 5°C to + 22°C ʯ Application range heating air side -25°C to +25°C ʯ Application range heating water side +9°C to +60°C ʯ Compact design with built-in hydraulic kit: no buffer tank required, standard inverter driven pump, expansion vessel, main flow sensor included

ʯ Easy installation and maintenance ʯ Separate MMI-2 controller for indoor installation

Air cooled mini inverter heat pump

Heating & Cooling EWYA 009DV3P 011DV3P 014DV3P 016DV3P 009DW1P 011DW1P 014DW1P 016DW1P Single phase Three phases

Price € 5.214,- 5.592,- 5.993,- 6.417,- 5.320,- 5.703,- 6.113,- 6.549,-Cooling capacity Nom. kW 9,35(1)/9,10(2) 11,6(1)/1,5(2) 12,8(1)/12,7(2) 14,0(1)/ 15,3(2) 9,35(1)/9,10(2) 11,6(1)/11,5(2) 12,8(1)/12,7(2) 14,0(1)/15,3(2)

Heating capacity Nom. kW 9,37(3)/9,00 (4) 10,6(3)/9,82(4) 12,0(3)/12,5(4) 16,0(3)/16,0(4) 9,37(3)/9,00(4) 10,6(3)/9,82(4) 12,0(3)/12,5(4) 16,0(3)/16,0(4)

Power input Cooling Nom. kW 2,79(1)/1,71 (2) 3,56(1)/2,17(2) 4,06(1)/2,51(2) 4,58(1)/3,24(2) 2,79(1)/1,71 (2) 3,56(1)/2,17(2) 4,06(1)/2,51(2) 4,58(1)/3,24(2)

Power input Heating Nom. kW 1,91(3)/2,43(4) 2,18(3)/2,68(4) 2,46(3)/3,42(4) 3,53(3)/4,56(4) 1,91(3)/2,43(4) 2,18(3)/2,68(4) 2,46(3)/3,42(4) 3,53(3)/4,56(4)

SEER(5) 5,62 5,79 5,71 5,59 5,62 5,79 5,71 5,59Space cooling ηs,c % 222 229 226 221 222 229 226 221EER 3,35(1)/5,34(2) 3,26(1)/5,31(2) 3,16(1)/5,04(2) 3,06(1)/4,74(2) 3,35(1)/5,34(2) 3,26(1)/5,31(2) 3,16(1)/5,04(2) 3,06(1)/4,74(2)

Space heating Average climate water outlet 35°C

General SCOP 4,82 4,73 4,7 4,69 4,82 4,73 4,7 4,69

Average climate water outlet 35°C

General ηs (Seasonal space heating efficiency)

% 190 186 185 185 190 186 185 185

Average climate water outlet 35°C

General Seasonal space heating eff, class A+++ A+++

COP 4,91(3)/3,71(4) 4,83(3)/3,66(4) 4,87(3)/3,64(4) 4,53(3)/3,51(4) 4,91(3)/3,71(4) 4,83(3)/3,66(4) 4,87(3)/3,64(4) 4,53(3)/3,51(4)

Refrigerant Circuits Quantity 1 1Compressor Quantity 1 1Dimensions Unit Depth x Width x Height mm 460 x 1.380 x 870 460 x 1.380 x 870Weight Unit / Operation weight kg 147 147Sound power level / Sound pressure level

Cooling Nom. dBA 65,5/44,0 67,0/47,7 69,0/50,8 69,0/51,0 65,5/44,0 67,0/47,7 69,0/50,8 69,0/51,0

Power supply Phase / Frequency / Voltage Hz / V 1~/50/230 3~/50/400

(1) Cooling: EW 12°C; LW 7°C; ambient conditions: 35°CDB; (2) Cooling: EW 23°C; LW 18°C; ambient conditions: 35°CDB; (3)Condition: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C); (4) Condition: Ta DB/WB 7°C/6°C - LWC 45°C (Dt=5°C); (5) According to EN14825

14

Air cooled mini inverter heat pump

Heating & Cooling EWYA(6) 009DV3P-H- 011DV3P-H- 014DV3P-H- 016DV3P-H- 009DW1P-H- 011DW1P-H- 014DW1P-H- 016DW1P-H- Single phase Three phases

Price € 5.955,- 6.333,- 6.734,- 7.158,- 6.060,- 6.444,- 6.854,- 7.290,-Cooling capacity Nom. kW 9,35(1)/9,10(2) 11,6(1)/11,5(2) 12,8(1)/12,7(2) 14,0(1)/15,3(2) 9,35(1)/9,10(2) 11,6(1)/11,5(2) 12,8(1)/12,7(2) 14,0(1)/15,3(2)

Heating capacity Nom. kW 9,37(3)/9,00 (4) 10,6(3)/9,82(4) 12,0(3)/12,5(4) 16,0(3)/16,0(4) 9,37(3)/9,00 (4) 10,6(3)/9,82(4) 12,0(3)/12,5(4) 16,0(3)/16,0(4)

Power input Cooling Nom. kW 2,79(1)/1,71 (2) 3,56(1)/2,17(2) 4,06(1)/2,51(2) 4,58(1)/3,24(2) 2,79(1)/1,71 (2) 3,56(1)/2,17(2) 4,06(1)/2,51(2) 4,58(1)/3,24(2)

Power input Heating Nom. kW 1,91(3)/2,43(4) 2,18(3)/2,68(4) 2,46(3)/3,42(4) 3,53(3)/4,56(4) 1,91(3)/2,43(4) 2,18(3)/2,68(4) 2,46(3)/3,42(4) 3,53(3)/4,56(4)

SEER(5) 5,62 5,79 5,71 5,59 5,62 5,79 5,71 5,59Space cooling ηs,c % 222 229 226 221 222 229 226 221EER 3,35(1)/5,34(2) 3,26(1)/5,31(2) 3,16(1)/5,04(2) 3,06(1)/4,74(2) 3,35(1)/5,34(2) 3,26(1)/5,31(2) 3,16(1)/5,04(2) 3,06(1)/4,74(2)

Space heating Average climate water outlet 35°C

General SCOP 4,82 4,73 4,7 4,69 4,82 4,73 4,7 4,69

Average climate water outlet 35°C

General ηs (Seasonal space heating efficiency)

% 190 186 185 185 190 186 185 185

Average climate water outlet 35°C

General Seasonal space heating eff, class A+++ A+++

COP 4,91(3)/3,71(4) 4,83(3)/3,66(4) 4,87(3)/3,64(4) 4,53(3)/3,51(4) 4,91(3)/3,71(4) 4,83(3)/3,66(4) 4,87(3)/3,64(4) 4,53(3)/3,51(4)

Refrigerant Circuits Quantity 1 1Compressor Quantity 1 1Dimensions Unit Depth x Width x Height mm 460 x 1.380 x 870 460 x 1.380 x 870Weight Unit / Operation weight kg 147 147Sound power level / Sound pressure level

Cooling Nom. dBA 65,5/44,0 67,0/47,7 69,0/50,8 69,0/51,0 65,5/44,0 67,0/47,7 69,0/50,8 69,0/51,0

Power supply Phase / Frequency / Voltage Hz / V 1~/50/230 3~/50/400

EWYA-DV3P-H/DW1P-H- ʯ Inverter controlled swing compressor with refrigerant R-32 ʯ R-32 refrigerant: reduced environmental impact and 30% less refrigerant charge needed

ʯ Application range cooling air side + 10°C to + 43°C ʯ Application range cooling water side + 5°C to + 22°C ʯ Application range heating air side -25°C to +25°C ʯ Application range heating water side +9°C to +60°C ʯ Compact design with built-in hydraulic kit: no buffer tank required, standard inverter driven pump, expansion vessel, main flow sensor included

ʯ Easy installation and maintenance ʯ Separate MMI-2 controller for indoor installation ʯ Water piping heater tape (OP10) as standard for a better insulation ʯ of the hydraulic

(1) Cooling: EW 12°C; LW 7°C; ambient conditions: 35°CDB; (2) Cooling: EW 23°C; LW 18°C; ambient conditions: 35°CDB; (3)Condition: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C)(4) Condition: Ta DB/WB 7°C/6°C - LWC 45°C (Dt=5°C); (5) According to EN14825; (6) EWYA-D(VP3/W1P)-H- has water piping heater tape (OP10) as standard

Kit availability for Mini-Chiller EWAA(011/014/016) DA(V3P/W1P) (-H-) EWYA(009/011/014/016) DA(V3P/W1P) (-H-)EKRP1HBA (1) Digital I/O PCB € 177,- 177,-EKRP1AHT Demand PCB € 172,- 172,-BRC1HHDK Remote user interface - Madoka black € 132,- 132,-BRC1HHDS Remote user interface - Madoka silver € 132,- 132,-BRC1HHDW Remote user interface - Madoka white € 132,- 132,-BRP069A78 LAN cartridge € 40,- 40,-EKRELSG Smart grid relay € 114,- 114,-KRCS01-1(2) Remote indoor sensor € 95,- 95,-EKRSC1(2) Decentralized outside temperature sensor € 110,- 110,-EKPCCAB4 PC cable € 362,- 362,-EKCC-W Universal controller for cascade control € 1.159,- 1.159,-EKLBUHCB6W1(3)(4) BUH kit - electric heater € - 910,-EKMBHBP (3) (4) BY-pass valve for BHU monobloc € - 218,-EKFLSW1 (5) Flow Switch € 114,- 114,-AFVALVE1 Freese protection valve € 126,- 126,-EKRTWA Wired room thermostat € 169,- 169,-EKRTR Wireless room thermostat, 230 V € 330,- 330,-EKRTETS(6) External temperature sensor option kit € 21,- 21,-

(1) Additional relays to allow bivalent control in combination with an external room thermostat are field-supplied.(2) Only 1 remote sensor can be connected: indoor OR outdoor sensor.(3) Dedicated connection kit available: see ESK RX12-709(4) Necessity to install a bypass kit EKMBHBP1 to avoid sweat on the BUH, when the BUH is installed in combination with a reversible model.(5) EKFLSW1· is obligatory for Monoblock & Mini-chiller in case Glycol is used(6) Can only be used in combination with the wireless room thermostat.

Applied Systems Price list 2021-2022 15

Unit size (without pump) EWAQ-CWN 016 021 025 032 040 050 064Price € 7.827,- 9.213,- 10.391,- not compliant (4) 15.853,- 17.662,- not compliant (4)

Unit size (with standard pump) EWAQ-CWP 016 021 025 032 040 050 064Price € 8.671,- 10.081,- 11.278,- 13.135,- 17.066,- 18.902,- 21.681,-Unit size (with high lift pump) EWAQ-CWH(4) 016 021 025 032 040 050 064Price € 9.006,- 10.417,- 11.613,- 13.591,- 17.539,- 19.380,- not compliant (4)

Cooling Capacity (MAX)(3) EWYQ - CWN(1) / CWP(2) kW 20,0 / 20,2 25,0 / 25,2 30,1 / 30,3 37,6 / 37,8 50,1 / 50,3 60,1 / 60,3 75,2 / 75,3

Cooling capacity (nominal)(3) EWAQ - CWN / CWP kW 16,8 / 17,0 21,0 / 21,2 25,3 / 25,5 31,6 / 31,8 42,1 / 42,3 50,5 / 50,7 63,2 / 63,3SEER(5) EWAQ - CWN(1) / CWP(2) 4,68 / 4,53 4,53 / 4,40 4,58 / 4,48 4,15 / 4,10 4,28 / 4,15 4,38 / 4,28 4,10 / 4,03Sound power level dB(A) 78 78 78 80 81 81 83

OptionsOP10 Evaporator electric heater € 626,- 626,- 626,- 627,- 788,- 788,- 788,-

OPZL Low leaving water operation down to -10°C and operation in cooling down to -15°C outside air temperature

€ 469,- 470,- 469,- 468,- 626,- 625,- 626,-

KitEKRP1AHT

Additional board for external control, on/off device, heating /cooling switch

€ 172,- 172,- 172,- 172,- 172,- (2 pcs) 172,- (2 pcs) 172,- (2 pcs)

EKRUAHTB

Additional control unit € 261,- 261,- 261,- 261,- 261,- 261,- 261,-

BHGP26A1

Digital pressure display € 582,- 582,- 582,- 582,- 582,- (2 pcs) 582,- (2 pcs) 582,- (2 pcs)

DTA104A62-9

Additional board for demand and noise reduction

€ 487,- 487,- 487,- 487,- 487,-(2 pcs) 487,- (2 pcs) 487,- (2 pcs)

RTD-W

Modbus interface € 409,- 409,- 409,- 409,- 409,- 409,- 409,-

EWAQ-CW ʯ Inverter controlled scroll compressor with refrigerant R-410A ʯ High efficiency with leader-of-class SEER. ʯ No buffer tank required for standard applications ʯ Application range cooling air side -15°C to +43°C ʯ Application range cooling water side -10°C to +20°C ʯ Communication to the building management system via RTD-W module

ʯ Hydraulic module with integrated pump and without pump available

ʯ Expansion vessel, flow controller, water filter, shut-off valve, drain/filling valve, control panel included

Air cooled scroll inverter chiller

Notes:

(1) EWYQ-CWN: Version without pump

(2) EWYQ-CWP: Version with pump

(3) Cooling: Ta DB/WB 35°C - LWE 7°C ( DT = 5°C) data according EN 14511: 2011

(4) EWAQ032CWN, EWAQ064CWN and EWAQ064CWH are not compliant to Ecodesign Lot21. As alternative to size EWAQ032CWN, equivalent models with low lift pump or high lift

pump (EWAQ032CWP/H) can be offered. As alternative to sizes EWAQ064CWN and EWAQ064CWH equivalent model with low lift pump (EWAQ064CWP) can be offered.

(5) According to Eurovent web site: https://www.eurovent-certification.com/enclose/

16

Unit size (without pump) EWYQ-CWN 016 021 025 032 040 050 064Price € 9.000,- 10.596,- 11.951,- 13.782,- 18.226,- 20.307,- 23.453,-Unit size (with standard pump) EWYQ-CWP 016 021 025 032 040 050 064Price € 9.862,- 11.484,- 12.860,- 14.959,- 19.479,- 21.591,- 24.786,-Unit size (with high lift pump) EWYQ-CWH 016 021 025 032 040 050 064Price € 10.198,- 11.819,- 13.196,- 15.058,- 19.953,- 22.064,- 25.264,-Cooling capacity (MAX)(3) EWYQ - CWN(1) / CWP(2) kW 20,0 / 20,0 25,0 /25,2 30,1 / 30,3 37,6 / 37,8 50,1 / 50,3 60,1 / 60,3 75,2 / 75,3Cooling capacity (nominal)(3) EWYQ - CWN(1) / CWP(2) kW 16,8 / 17,0 21,0 / 21,2 25,1 / 25,5 31,6 / 31,8 42,1 / 42,3 50,5 / 50,7 63,2 / 63,3SEER(5) EWYQ - CWN(1) / CWP(2) 4,28 / 4,68 3.05 / 3,07 4,20 / 4,58 3,93 / 4,15 4,18 / 4,28 4,20 / 4,38 3,93 / 4,10Heating capacity (MAX)(4) EWYQ - CWN(1) / CWP(2) kW 20,0 / 19,8 25,0 / 24,8 29,9 / 29,7 37,4 / 37,2 49,9 / 49,7 59,9 / 59,7 74,9 / 74,7Heating capacity (nominal)(4) EWYQ - CWN(1) / CWP(2) kW 16,8 / 16,6 21,0 / 20,8 25,1 / 24,9 31,4 / 31,2 41,9 / 41,7 50,3 / 50,1 62,9 / 62,7COP (nominal) EWYQ - CWN / CWP 3,00 / 3,02 3,05 / 3,07 2,87 / 2,91 2,91 / 2,93 3,06 / 3,03 2,87 / 2,88 2,91 / 2,93Space heating

Average climate water outlet 35°C

General ηs (Seasonal space heating efficiency) % 147(1)/144(2) 148(1)/154(2) 138(1)/139(2) 135(1)/138(2) 149(1)/149(2) 139(1)/139(2) 135(1)/138(2)

SCOP 3,75(1)/3,68(2) 3,78(1)/3,93(2) 3,53(1)/3,55(2) 3,45(1)/3,53(2) 3,80(1)/3,80(2) 3,55(1)/3,55(2) 3,45(1)/3,53(2)

Seasonal space heating eff. class

A+(1)/A+(2) A++(1)/A++(2) A+(1)/A+(2) A+(1)/A+(2) A+(1)/A+(2) A+(1)/A+(2) A+(1)/A+(2)

Sound power level dB(A) 78 78 78 80 81 81 83

OptionsOP10 Evaporator electric heater € 625,- 626,- 627,- 626,- 788,- 788,- 788,-

OPZL Low leaving water operation down to -10°C and operation in cooling down to -15°C outside air temperature

€ 468,- 470,- 470,- 469,- 626,- 626,- 625,-

KitEKRP1AHT

Additional board for external control, on/off device, heating /cooling switch

€ 172,- 172,- 172,- 172,- 172,- (2 pcs) 172,- (2 pcs) 172,- (2 pcs)

EKRUAHTB

Additional control unit € 261,- 261,- 261,- 261,- 261,- 261,- 261,-

BHGP26A1

Digital pressure display € 582,- 582,- 582,- 582,- 582,- (2 pcs) 582,- (2 pcs) 582,- (2 pcs)

DTA104A62-9

Additional board for demand and noise reduction

€ 487,- 487,- 487,- 487,- 487,-(2 pcs) 487,- (2 pcs) 487,- (2 pcs)

RTD-W

Modbus interface € 409,- 409,- 409,- 409,- 409,- 409,- 409,-

EWYQ-CW ʯ Inverter controlled scroll compressor with refrigerant R-410A ʯ Wide operation range, ambient temperature in heating down to -15°C

ʯ No buffer tank required for standard applications ʯ Application range cooling air side -15°C to +43°C ʯ Application range cooling water side -10°C to +20°C ʯ Application range heating air side -15°C to +35°C ʯ Application range heating water side +25°C to +50°C ʯ Communication to the building management system via RTD-W module

ʯ Hydraulic module with integrated pump and without pump available

Air cooled scroll inverter heat pump

Notes:

(1) EWYQ-CWN: Version without pump

(2) EWYQ-CWP: Version with pump

(3) Cooling: Ta DB/WB 35°C - LWE 7°C ( DT = 5°C) data according EN 14511: 2011

(4) Heating: Ta DB/WB 7°C/6°C - LWC 45°C (Dt=5°C), data according EN 14511: 2011

(5) According to Eurovent web site: https://www.eurovent-certification.com/enclose/

ʯ Expansion vessel, flow controller, water filter, shut-off valve, drain/filling valve, control panel included

Applied Systems Price list 2021-2022 17

Unit size 20 32 40 64Indoor unit 1× SEHVX20BW 1× SEHVX32BW 1× SEHVX40BW 1× SEHVX64BWOutdoor Units 1× SERHQ020BW1 1× SERHQ032BW1 2× SERHQ020BW1 2× SERHQ032BW1Indoor unit Price per each € 4.691,- 5.242,- 5.498,- 5.598,-Outdoor unit Price per each € 7.021,- 9.888,- 7.021,- 9.888,-Unit Price per each (indoor + outdoor(s)) € 11.712,- 15.130,- 19.540,- 25.374,-Cooling Capacity (nominal)(1) kW 21,2 31,8 42,3 63,3Cooling Capacity (maximum)(1) kW 25,2 37,8 50,3 75,3EER 2,84 2,50 2,80 2,48SEER(3) 4,40 4,10 4,15 4,03Heating Capacity (nominal)(2) kW 20,8 31,2 41,7 62,7Heating Capacity (maximum)(2) kW 24,8 37,2 49,7 74,7COP 3,07 2,93 3,03 2,93Space heating Average

climate water outlet 35°C

ηs (Seasonal space heating efficiency)

% 154 138 149 138

SCOP 3,93 3,53 3,80 3,53

Seasonal space heating eff. class A++ A+ A+ A+

Sound power level (outdoor unit / each) dB(A) 78 80 81 83

Standard Options SEHVX20BW SEHVX32BW SEHVX40BW SEHVX64BWStandard Hydraulic packageOne centrifugal pump

€ including as standard including as standard including as standard including as standard

Kit Design size 020 032 040 064EKRP1AHT

Additional board for external control, on/off device, heating /cooling switch

€ 172,- 172,- 172,- (2 pcs) 172,- (2 pcs)

DTA104A62-9

Additional board for demand and noise reduction

€ 487,- 487,- 487,- (2 pcs) 487,- (2 pcs)

RTD-W

Modbus interface € 409,- 409,- 409,- 409,-

EKCC-WAdditional module for cascade control of up to 16 EWAQ ** devices including power supply

€ 1.159,- 1.159,- 1.159,- 1.159,-

SEHVX-BW ʯ Inverter controlled scroll compressor with refrigerant R-410A ʯ Wide operation range, ambient temperature in heating down to -15°C

ʯ No buffer tank required for standard applications ʯ Application range cooling air side -5°C to +43°C ʯ Application range cooling water side +5°C to +20°C ʯ Application range heating air side -15°C to +35°C ʯ Application range heating water side +25°C to +50°C ʯ Communication to the building management system via RTD-W module

ʯ Expansion vessel, flow controller, water filter, shut-off valve, drain/filling valve, control panel included

ʯ Distance between outdoor and indoor unit: max 30 meters

Air cooled scroll inverter heat pump - split version

Notes:

(1) Cooling: Ta DB/WB 35°C - LWE 7°C ( DT = 5°C) data according EN 14511: 2011

(2) Heating: Ta DB/WB 7/6°C - LWC 35°C (DT = 5°C), data according EN 14511: 2011

(3) According to Eurovent web site: https://www.eurovent-certification.com/enclose/

ʯ Height difference between outdoor and indoor unit: max 10 meters

18

EWYQ-CWPAn example scheme of the hydronic connection for the unit EWYQ-CWP is shown below. In the picture 1 the unit is equipped with a standard pump.

SEHVX-BWAn example scheme of the hydronic connections for the units SEHVX-BW/ SERHQ-BW1 is shown in Picture 2 & Picture 3.

Picture 2 – outdoor unit SERHQ020/032BW1 (size 20 or 32) with the hydronic connection to the related indoor unit SEHVX20/32BW.

Picture 3 - two outdoor units SERHQ020/032BW1 (size 40 or 64) with the hydronic connection to the related indoor unit SEHVX40/64BW. As seen from the scheme, these materials consist of two outdoor units.

Hydronic connection examples

Water/Glycol Mixture

Picture 1

Outdoor UnitEWYQ-CWP

DAG

P/HP

Applied Systems Price list 2021-2022 19

Water line

Water line

Indoor UnitSEHVX20BW/SEHVX32BW

Indoor UnitSEHVX40BW/SEHVX64BW

Outdoor UnitSERHQ020BW1/SERHQ032BW1

Outdoor UnitSERHQ020BW1/SERHQ032BW1

Outdoor UnitSERHQ020BW1/SERHQ032BW1

Refrigerant line

Refrigerant line

DAG

DAG

P/HP

P/HP

Picture 2

Picture 3

20

EWYT-B Multi scroll Air heat pump with R-32 refrigerantLeading the way in reducing environmental impactFeatures: ʯ Environmentally friendly R-32 refrigerant with a low Global Warming Potential (GWP) and low flammability classification can be safely used in many applications

ʯ Comfort cooling and heating applications

ʯ Capacity range from 80kW to 670 kW

ʯ Two efficiency version with COP up to 3,5 (at nominal conditions): gold (high efficiency) and silver (standard efficiency)

ʯ Three sound configurations: standard, low and reduced - each one designed to meet stringent acoustic requirements

ʯ Two different layouts: parallel coil (standardly equipped with continuous fan speed modulation) and double V coil

ʯ Outstanding reliability: one or two independent refrigerant circuits with two or three compressors

ʯ Extended operating range, hot water up to 60°C

ʯ Fully compatible with the Daikin on Site cloud-based platform including remote monitoring, system optimization and preventive maintenance

ʯ Master/Slave control as standard allowing the management of up to 4 units without any external control devices

ʯ Extensive option list (more than 70) in order to provide full customisation on project-specific requirements

Parallel Coil layout (mono/dual circuit)

Double V Coil layout (dual circuit)

First in the Market!

NEW

Applied Systems Price list 2021-2022 21

EWYT-B-SSStandard efficiency rating, standard noise level

ʯ R-32 refrigerant with low GWP. Reduced amount of refrigerant tanks to micro channel heat exchanger technology

ʯ Capacity range from 80kW to 670 kW ʯ Two efficiency level and 3 sound configurations ʯ Two different layouts: parallel coil (standardly equipped with continuous fan speed modulation) and double V coil

ʯ One or two independent refrigerant circuits with two or three compressors

ʯ Extended operating range, hot water up to 60°C ʯ Fully compatible with the Daikin on Site cloud-based platform including remote monitoring, system optimization and preventive maintenance

Air cooled heat pump

Type of unit (rated power in accordance with EN14511) EWYT -B-SS 85 105 135 175 205 215Price € 21.683,- 25.137,- 28.469,- 34.132,- 44.170,- 41.760,-Commissioning by DAIKIN service (net price) € on request on request on request on request on request on requestCooling capacity kW 75 98 120 153 189 193Power input - cooling kW 28 36,6 44,8 57,9 71,4 72,3Heating capacity kW 82 106 132 170 209 213Power input - heating kW 28,2 36,6 45,4 59,1 72,5 74,0Refrigerant circuit 1 1 1 1 2 1Compressors 2 2 2 2 4 2EER 2,68 2,67 2,69 2,64 2,65 2,67SEER 3,90 3,98 3,90 4,01 3,96 3,90COP 2,914 2,903 2,914 2,875 2,886 2,884SCOP 3,34 3,41 3,36 3,40 3,37 3,40Length x Width x Height mm 2.225x1.195x1.800 2.825x1.195x1.800 3.425x1.195x1.800 3.425x1.195x1.800 4.350x1.195x1.800 4.025x1.195x1.800Weight of unit / Operating weight kg 955/962 1.065/1.072 1.165/1.172 1.320/1.327 1.500/1.511 1.500/1.511Sound power / Sound pressure (at 1m) dB(A) 83,8/66,4 87,2/69,4 89,1/70,9 90,8/72,6 89,9/71,2 92,2/73,7Buffer tank volume / option (OP 134/135/136/137)(1) liter 70 145 145 190 250 250

Optional accessories for chiller:Code Type of unit EWYT -B-SS 85 105 135 175 205 215Mechanical03A Partial heat recovery with control € 1.112,- 1.112,- 1.137,- 1.137,- 2.425,- 1.325,-08 Brine version € on request on request on request on request on request on request20 Evaporator victaulic kit € Standard44 Evaporator area guard € n/a21 Evaporator flange kit € 149,- 149,- 149,- 149,- 149,- 149,-29 20mm evaporator insulation € Standard43 Condenser coil guards € 401,- 474,- 518,- 518,- 647,- 647,-45 Cu-Cu condenser coil € n/a46 Cu-Cu-Sn condenser coil € n/a49 Alucoat fins coil € Standard61 Discharge line shut-off valve € 297,- 297,- 297,- 297,- 578,- 361,-62 Suction line shut-off valve € 490,- 490,- 490,- 490,- 971,- 563,-63 High pressure side manometers € 153,- 153,- 153,- 153,- 261,- 153,-64 Low pressure side manometers € 153,- 153,- 153,- 153,- 261,- 153,-78 One centrifugal pump (low lift) € 2.662,- 2.662,- 2.662,- 3.108,- 3.321,- 3.108,-79 One centrifugal pump (high lift) € 3.108,- 3.108,- 3.108,- 3.132,- 4.201,- 3.293,-80 Two centrifugal pump (low lift) € 3.927,- 3.927,- 4.682,- 4.738,- 5.702,- 5.060,-81 Two centrifugal pump (high lift) € 4.682,- 4.682,- 5.340,- 6.024,- 6.264,- 6.104,-91 Double pressure relief valve with diverter € 943,- 943,- 943,- 943,- 1.401,- 943,-115 Water filter € 265,- 265,- 265,- 265,- 265,- 265,-117 Blygold coil treatment € 2.915,- 3.413,- 4.718,- 4.718,- 5.120,- 5.120,-121 Refrigerant leak detection € 1.032,- 1.032,- 1.032,- 1.032,- 1.032,- 1.032,-134 One centrifugal pump (low lift) + tank € 4.313,- 4.313,- 4.313,- 4.762,- 7.120,- 4.762,-135 One centrifugal pump (high lift) + tank € 4.762,- 4.762,- 5.867,- 5.867,- 8.279,- 5.867,-136 Two centrifugal pump (low lift) + tank € 5.802,- 5.802,- 5.910,- 6.441,- 9.252,- 6.441,-137 Two centrifugal pump (high lift) + tank € 6.441,- 6.441,- 7.256,- 8.095,- 9.714,- 8.834,-

22

Optional accessories for chiller:Code Type of unit EWYT -B-SS 85 105 135 175 205 215Electrical / Control04 Direct on line starter (dol) € Standard06 Soft starter € 1.839,- 2.048,- 2.209,- 2.904,- 3.899,- 3.273,-10 Double setpoint € Standard11 Compressor thermal overload relays € n/a

15 Under / over voltage control € 241,- 241,- 241,- 241,- 241,- 241,-16 Energy meter € 1.253,- 1.253,- 1.253,- 1.253,- 1.253,- 1.253,-17 Capacitors for power factor correction € n/a17B Capacitors for power factor correction (single-v) € 494,- 526,- 554,- 662,- 1.048,- 771,-42 Speedtrol € n/a57 Evaporator electric heater € Standard58 Evaporator flow switch € 297,- 297,- 297,- 297,- 297,- 297,-60 Electronic expansion valve € Standard

67 Ambient outside temperature sensor and setpoint reset € Standard

68 Hour run meter € Standard69 General fault contactor € Standard70 Alarm from external device € Standard95 Compressors circuit breakers € 305,- 341,- 378,- 466,- 682,- 550,-96 Fans circuit breakers € 177,- 177,- 177,- 177,- 177,- 177,-97 Main switch interlock door € Standard99 Fans speed regulation (+ fan silent mode) € Standard99a Fans speed regulation (vfd) € n/a102 Ground fault relay € n/a114 Nordic kit € 943,- 1.112,- 1.285,- 1.679,- 2.096,- 2.096,-142A High ambient kit € on request on request on request on request on request on request120E Inverter kit for 1 centr pump low lift € 976,- 976,- 999,- 1.056,- 1.056,- 1.056,-120F Inverter kit for 1 centr pump high lift € 1.056,- 1.056,- 1.056,- n/a120G Inverter kit for 2 centr pump low lift € n/a 2.108,- n/a120H Inverter kit for 2 centr pump high lift € n/a120I Inv kit 1 centr pump low lift and tank € 976,- 976,- 999,- 1.056,- 1.056,- 1.056,-120J Inv kit 1 centr pump high lift and tank € 1.056,- 1.056,- 1.056,- n/a120K Inv kit 2 centr pump low lift and tank € n/a 2.108,- n/a120L Inv kit 2 centr pump high lift and tank € n/a128 Master/slave € Standard144 Diff pressure transd (shipped loose) € on request on request on request on request on request on request188 Heating only mode € 345,- 345,- 345,- 345,- 345,- 345,-184 iCM standard € 1.606,- 1.606,- 1.606,- 1.606,- 1.606,- 1.606,-180 Modbus RTU MSTP € 522,- 522,- 522,- 522,- 522,- 522,-181 BACNet MSTP € 522,- 522,- 522,- 522,- 522,- 522,-182 BACNet IP € 522,- 522,- 522,- 522,- 522,- 522,-155 Daikin on site modem (with antenna) € 755,- 755,- 755,- 755,- 755,- 755,-160 100 Pa ESP fan € on request on request on request on request on request on requestInstallation75 Rubber anti vibration mounts € 393,- 393,- 393,- 393,- 393,- 393,-77 Spring anti vibration mounts € 1.221,- 1.221,- 1.221,- 1.221,- 1.221,- 1.221,-83 External tank without cabinet (500 l)(1) € 2.999,- 2.999,- 2.999,- 2.999,- 2.999,- 2.999,-84 External tank without cabinet (1000 l)(1) € 4.003,- 4.003,- 4.003,- 4.003,- 4.003,- 4.003,-87 External tank with cabinet (500 l)(1) € 4.413,- 4.413,- 4.413,- 4.413,- 4.413,- 4.413,-88 External tank with cabinet (1000 l)(1) € 5.649,- 5.649,- 5.649,- 5.649,- 5.649,- 5.649,-Communication cards / AccessoriesEKCMLON BMS card (LonWorks) € 420,- 420,- 420,- 420,- 420,- 420,-EKCM200J BMS Card (ModBus RTU) € 359,- 359,- 359,- 359,- 359,- 359,-EKCMBACIP BMS card (BACnet/IP) € 582,- 582,- 582,- 582,- 582,- 582,-

(1) Preliminary data

(2) Piping between the inertial tank and the unit is not included. Electric heater power supply has to be provided from external source

(3) Some options are not compatible each other. Please contact Daikin Sales Office to know the “incompatibility list” of the above mentioned options

Air cooled heat pump

Applied Systems Price list 2021-2022 23

EWYT-B-SLStandard efficiency rating, low noise level

ʯ R-32 refrigerant with low GWP. Reduced amount of refrigerant tanks to micro channel heat exchanger technology

ʯ Capacity range from 80kW to 670 kW ʯ Two efficiency level and 3 sound configurations ʯ Two different layouts: parallel coil (standardly equipped with continuous fan speed modulation) and double V coil

ʯ One or two independent refrigerant circuits with two or three compressors

ʯ Extended operating range, hot water up to 60°C ʯ Fully compatible with the Daikin on Site cloud-based platform including remote monitoring, system optimization and preventive maintenance

Air cooled heat pump

Type of unit (rated power in accordance with EN14511) EWYT-B-SL 85 105 135 175 205 215Price € 22.735,- 26.257,- 29.562,- 35.267,- 45.350,- 42.817,-Commissioning by DAIKIN service (net price) € on request on request on request on request on request on requestCooling capacity kW 75 98 120 153 189 193Power input - cooling kW 28 36,6 44,8 57,9 71,4 72,3Heating capacity kW 82 106 132 170 209 213Power input - heating kW 28,2 36,6 45,4 59,1 72,5 74,0Refrigerant circuit 1 1 1 1 2 1Compressors 2 2 2 2 4 2EER 2,68 2,67 2,69 2,64 2,65 2,67SEER 3,90 3,98 3,90 4,01 3,96 3,90COP 2,914 2,903 2,914 2,875 2,886 2,884SCOP 3,34 3,41 3,36 3,40 3,37 3,40Length x Width x Height mm 2.225x1.195x1.800 2.825x1.195x1.800 3.425x1.195x1.800 3.425x1.195x1.800 4.350x1.195x1.800 4.025x1.195x1.800Weight of unit / Operating weight kg 985/992 1.095/1.102 1.195/1.202 1.350/1.357 1.530/1.541 1.530/1.541Sound power / Sound pressure (at 1m) dB(A) 82,7/65,3 85,2/67,4 86,8/68,6 87,8/69,6 87,7/69,0 89,0/70,5Buffer tank volume / option (OP 134/135/136/137)(1) liter 70 145 145 190 250 250

Optional accessories for chiller:Code Type of unit EWYT-B-SL 85 105 135 175 205 215Mechanical03A Partial heat recovery with control € 1.112,- 1.112,- 1.137,- 1.137,- 2.425,- 1.325,-08 Brine version € on request on request on request on request on request on request20 Evaporator victaulic kit € Standard44 Evaporator area guard € n/a21 Evaporator flange kit € 149,- 149,- 149,- 149,- 149,- 149,-29 20mm evaporator insulation € Standard43 Condenser coil guards € 401,- 474,- 518,- 518,- 647,- 647,-45 Cu-Cu condenser coil € n/a46 Cu-Cu-Sn condenser coil € n/a49 Alucoat fins coil € Standard61 Discharge line shut-off valve € 297,- 297,- 297,- 297,- 578,- 361,-62 Suction line shut-off valve € 490,- 490,- 490,- 490,- 971,- 563,-63 High pressure side manometers € 153,- 153,- 153,- 153,- 261,- 153,-64 Low pressure side manometers € 153,- 153,- 153,- 153,- 261,- 153,-78 One centrifugal pump (low lift) € 2.662,- 2.662,- 2.662,- 3.108,- 3.321,- 3.108,-79 One centrifugal pump (high lift) € 3.108,- 3.108,- 3.108,- 3.132,- 4.201,- 3.293,-80 Two centrifugal pump (low lift) € 3.927,- 3.927,- 4.682,- 4.738,- 5.702,- 5.060,-81 Two centrifugal pump (high lift) € 4.682,- 4.682,- 5.340,- 6.024,- 6.264,- 6.104,-91 Double pressure relief valve with diverter € 943,- 943,- 943,- 943,- 1.401,- 943,-115 Water filter € 265,- 265,- 265,- 265,- 265,- 265,-117 Blygold coil treatment € 2.915,- 3.413,- 4.718,- 4.718,- 5.120,- 5.120,-121 Refrigerant leak detection € 1.032,- 1.032,- 1.032,- 1.032,- 1.032,- 1.032,-134 One centrifugal pump (low lift) + tank € 4.313,- 4.313,- 4.313,- 4.762,- 7.120,- 4.762,-135 One centrifugal pump (high lift) + tank € 4.762,- 4.762,- 5.867,- 5.867,- 8.279,- 5.867,-136 Two centrifugal pump (low lift) + tank € 5.802,- 5.802,- 5.910,- 6.441,- 9.252,- 6.441,-137 Two centrifugal pump (high lift) + tank € 6.441,- 6.441,- 7.256,- 8.095,- 9.714,- 8.834,-

24

Optional accessories for chiller:Code Type of unit EWYT-B-SL 85 105 135 175 205 215Electrical / Control04 Direct on line starter (dol) € Standard06 Soft starter € 1.839,- 2.048,- 2.209,- 2.904,- 3.899,- 3.273,-10 Double setpoint € Standard11 Compressor thermal overload relays € n/a15 Under / over voltage control € 241,- 241,- 241,- 241,- 241,- 241,-16 Energy meter € 1.253,- 1.253,- 1.253,- 1.253,- 1.253,- 1.253,-17 Capacitors for power factor correction € n/a17B Capacitors for power factor correction (single-v) € 494,- 526,- 554,- 662,- 1.048,- 771,-42 Speedtrol € n/a57 Evaporator electric heater € Standard58 Evaporator flow switch € 297,- 297,- 297,- 297,- 297,- 297,-60 Electronic expansion valve € Standard

67 Ambient outside temperature sensor and setpoint reset € Standard

68 Hour run meter € Standard69 General fault contactor € Standard70 Alarm from external device € Standard95 Compressors circuit breakers € 305,- 341,- 378,- 466,- 682,- 550,-96 Fans circuit breakers € 177,- 177,- 177,- 177,- 177,- 177,-97 Main switch interlock door € Standard99 Fans speed regulation (+ fan silent mode) € Standard99a Fans speed regulation (vfd) € n/a102 Ground fault relay € n/a114 Nordic kit € 943,- 1.112,- 1.285,- 1.679,- 2.096,- 2.096,-142A High ambient kit € on request on request on request on request on request on request120E Inverter kit for 1 centr pump low lift € 976,- 976,- 999,- 1.056,- 1.056,- 1.056,-120F Inverter kit for 1 centr pump high lift € 1.056,- 1.056,- 1.056,- n/a120G Inverter kit for 2 centr pump low lift € n/a 2.108,- n/a120H Inverter kit for 2 centr pump high lift € n/a120I Inv kit 1 centr pump low lift and tank € 976,- 976,- 999,- 1.056,- 1.056,- 1.056,-120J Inv kit 1 centr pump high lift and tank € 1.056,- 1.056,- 1.056,- n/a120K Inv kit 2 centr pump low lift and tank € n/a 2.108,- n/a120L Inv kit 2 centr pump high lift and tank € n/a128 Master/slave € Standard144 Diff pressure transd (shipped loose) € on request on request on request on request on request on request188 Heating only mode € 345,- 345,- 345,- 345,- 345,- 345,-184 iCM standard € 1.606,- 1.606,- 1.606,- 1.606,- 1.606,- 1.606,-180 Modbus RTU MSTP € 522,- 522,- 522,- 522,- 522,- 522,-181 BACNet MSTP € 522,- 522,- 522,- 522,- 522,- 522,-182 BACNet IP € 522,- 522,- 522,- 522,- 522,- 522,-155 Daikin on site modem (with antenna) € 755,- 755,- 755,- 755,- 755,- 755,-160 100 Pa ESP fan € on request on request on request on request on request on requestInstallation75 Rubber anti vibration mounts € 393,- 393,- 393,- 393,- 393,- 393,-77 Spring anti vibration mounts € 1.221,- 1.221,- 1.221,- 1.221,- 1.221,- 1.221,-83 External tank without cabinet (500 l)(1) € 2.999,- 2.999,- 2.999,- 2.999,- 2.999,- 2.999,-84 External tank without cabinet (1000 l)(1) € 4.003,- 4.003,- 4.003,- 4.003,- 4.003,- 4.003,-87 External tank with cabinet (500 l)(1) € 4.413,- 4.413,- 4.413,- 4.413,- 4.413,- 4.413,-88 External tank with cabinet (1000 l)(1) € 5.649,- 5.649,- 5.649,- 5.649,- 5.649,- 5.649,-Communication cards / AccessoriesEKCMLON BMS card (LonWorks) € 420,- 420,- 420,- 420,- 420,- 420,-EKCM200J BMS Card (ModBus RTU) € 359,- 359,- 359,- 359,- 359,- 359,-EKCMBACIP BMS card (BACnet/IP) € 582,- 582,- 582,- 582,- 582,- 582,-

(1) Preliminary data

(2) Piping between the inertial tank and the unit is not included. Electric heater power supply has to be provided from external source

(3) Some options are not compatible each others. Please contact Daikin Sales Office to know the “incompatibility list” of the above mentioned options

Air cooled heat pump

Applied Systems Price list 2021-2022 25

EWYT-B-SRStandard efficiency rating, reduced noise level

ʯ R-32 refrigerant with low GWP. Reduced amount of refrigerant tanks to micro channel heat exchanger technology

ʯ Capacity range from 80kW to 670 kW ʯ Two efficiency level and 3 sound configurations ʯ Two different layouts: parallel coil (standardly equipped with continuous fan speed modulation) and double V coil

ʯ One or two independent refrigerant circuits with two or three compressors

ʯ Extended operating range, hot water up to 60°C ʯ Fully compatible with the Daikin on Site cloud-based platform ʯ including remote monitoring, system optimization and preventive maintenance

Air cooled heat pump

Type of unit (rated power in accordance with EN14511) EWYT-B-SR 85 105 135 175 205 215Price € 23.663,- 27.284,- 30.509,- 35.882,- 46.142,- 43.419,-Commissioning by DAIKIN service (net price) € on request on request on request on request on request on requestCooling capacity kW 74 96 119 150 186 189Power input - cooling kW 28,7 37,4 45,5 59,5 73,2 74,3Heating capacity kW 81 105 131 167 207 210Power input - heating kW 26,4 36,2 44,8 54,7 67,7 68,3Refrigerant circuit 1 1 1 1 2 1Compressors 2 2 2 2 4 2EER 2,56 2,58 2,61 2,53 2,54 2,55SEER 3,82 3,93 3,87 3,96 3,92 3,82COP 2,89 2,90 2,92 2,86 2,88 2,87SCOP 3,35 3,40 3,37 3,42 3,44 3,43Length x Width x Height mm 2.225x1.195x1.800 2.825x1.195x1.800 3.425x1.195x1.800 3.425x1.195x1.800 4.350x1.195x1.800 4.025x1.195x1.800Weight of unit / Operating weight kg 985/992 1.095/1.102 1.195/1.202 1.350/1.357 1.530/1.541 1.530/1.541Sound power / Sound pressure (at 1m) dB(A) 77,8/60,4 81,6/63,8 83,6/65,4 85,4/67,2 84,4/65,7 86,9/68,4Buffer tank volume / option (OP 134/135/136/137)(1) liter 70 145 145 190 250 250

Optional accessories for chiller:Code Type of unit EWYT-B-SR 85 105 135 175 205 215Mechanical03A Partial heat recovery with control € 1.112,- 1.112,- 1.137,- 1.137,- 2.425,- 1.325,-08 Brine version € on request on request on request on request on request on request20 Evaporator victaulic kit € Standard44 Evaporator area guard € n/a21 Evaporator flange kit € 149,- 149,- 149,- 149,- 149,- 149,-29 20mm evaporator insulation € Standard43 Condenser coil guards € 401,- 474,- 518,- 518,- 647,- 647,-45 Cu-Cu condenser coil € n/a46 Cu-Cu-Sn condenser coil € n/a49 Alucoat fins coil € Standard61 Discharge line shut-off valve € 297,- 297,- 297,- 297,- 578,- 361,-62 Suction line shut-off valve € 490,- 490,- 490,- 490,- 971,- 563,-63 High pressure side manometers € 153,- 153,- 153,- 153,- 261,- 153,-64 Low pressure side manometers € 153,- 153,- 153,- 153,- 261,- 153,-78 One centrifugal pump (low lift) € 2.662,- 2.662,- 2.662,- 3.108,- 3.321,- 3.108,-79 One centrifugal pump (high lift) € 3.108,- 3.108,- 3.108,- 3.132,- 4.201,- 3.293,-80 Two centrifugal pump (low lift) € 3.927,- 3.927,- 4.682,- 4.738,- 5.702,- 5.060,-81 Two centrifugal pump (high lift) € 4.682,- 4.682,- 5.340,- 6.024,- 6.264,- 6.104,-91 Double pressure relief valve with diverter € 943,- 943,- 943,- 943,- 1.401,- 943,-115 Water filter € 265,- 265,- 265,- 265,- 265,- 265,-117 Blygold coil treatment € 2.915,- 3.413,- 4.718,- 4.718,- 5.120,- 5.120,-121 Refrigerant leak detection € 1.032,- 1.032,- 1.032,- 1.032,- 1.032,- 1.032,-134 One centrifugal pump (low lift) + tank € 4.313,- 4.313,- 4.313,- 4.762,- 7.120,- 4.762,-135 One centrifugal pump (high lift) + tank € 4.762,- 4.762,- 5.867,- 5.867,- 8.279,- 5.867,-136 Two centrifugal pump (low lift) + tank € 5.802,- 5.802,- 5.910,- 6.441,- 9.252,- 6.441,-137 Two centrifugal pump (high lift) + tank € 6.441,- 6.441,- 7.256,- 8.095,- 9.714,- 8.834,-

26

Optional accessories for chiller:Code Type of unit EWYT-B-SR 85 105 135 175 205 215Electrical / Control04 Direct on line starter (dol) € Standard06 Soft starter € 1.839,- 2.048,- 2.209,- 2.904,- 3.899,- 3.273,-10 Double setpoint € Standard11 Compressor thermal overload relays € n/a15 Under / over voltage control € 241,- 241,- 241,- 241,- 241,- 241,-16 Energy meter € 1.253,- 1.253,- 1.253,- 1.253,- 1.253,- 1.253,-17 Capacitors for power factor correction € n/a17B Capacitors for power factor correction (single-v) € 494,- 526,- 554,- 662,- 1.048,- 771,-42 Speedtrol € n/a57 Evaporator electric heater € Standard58 Evaporator flow switch € 297,- 297,- 297,- 297,- 297,- 297,-60 Electronic expansion valve € Standard

67 Ambient outside temperature sensor and setpoint reset € Standard

68 Hour run meter € Standard69 General fault contactor € Standard70 Alarm from external device € Standard95 Compressors circuit breakers € 305,- 341,- 378,- 466,- 682,- 550,-96 Fans circuit breakers € 177,- 177,- 177,- 177,- 177,- 177,-97 Main switch interlock door € Standard99 Fans speed regulation (+ fan silent mode) € Standard99a Fans speed regulation (vfd) € n/a102 Ground fault relay € n/a114 Nordic kit € 943,- 1.112,- 1.285,- 1.679,- 2.096,- 2.096,-142A High ambient kit € on request on request on request on request on request on request120E Inverter kit for 1 centr pump low lift € 976,- 976,- 999,- 1.056,- 1.056,- 1.056,-120F Inverter kit for 1 centr pump high lift € 1.056,- 1.056,- 1.056,- n/a120G Inverter kit for 2 centr pump low lift € n/a 2.108,- n/a120H Inverter kit for 2 centr pump high lift € n/a120I Inv kit 1 centr pump low lift and tank € 976,- 976,- 999,- 1.056,- 1.056,- 1.056,-120J Inv kit 1 centr pump high lift and tank € 1.056,- 1.056,- 1.056,- n/a120K Inv kit 2 centr pump low lift and tank € n/a 2.108,- n/a120L Inv kit 2 centr pump high lift and tank € n/a128 Master/slave € Standard144 Diff pressure transd (shipped loose) € on request on request on request on request on request on request188 Heating only mode € 345,- 345,- 345,- 345,- 345,- 345,-184 iCM standard € 1.606,- 1.606,- 1.606,- 1.606,- 1.606,- 1.606,-180 Modbus RTU MSTP € 522,- 522,- 522,- 522,- 522,- 522,-181 BACNet MSTP € 522,- 522,- 522,- 522,- 522,- 522,-182 BACNet IP € 522,- 522,- 522,- 522,- 522,- 522,-155 Daikin on site modem (with antenna) € 755,- 755,- 755,- 755,- 755,- 755,-Installation75 Rubber anti vibration mounts € 393,- 393,- 393,- 393,- 393,- 393,-77 Spring anti vibration mounts € 1.221,- 1.221,- 1.221,- 1.221,- 1.221,- 1.221,-83 External tank without cabinet (500 l)(1) € 2.999,- 2.999,- 2.999,- 2.999,- 2.999,- 2.999,-84 External tank without cabinet (1000 l)(1) € 4.003,- 4.003,- 4.003,- 4.003,- 4.003,- 4.003,-87 External tank with cabinet (500 l)(1) € 4.413,- 4.413,- 4.413,- 4.413,- 4.413,- 4.413,-88 External tank with cabinet (1000 l)(1) € 5.649,- 5.649,- 5.649,- 5.649,- 5.649,- 5.649,-Communication cards / AccessoriesEKCMLON BMS card (LonWorks) € 420,- 420,- 420,- 420,- 420,- 420,-EKCM200J BMS Card (ModBus RTU) € 359,- 359,- 359,- 359,- 359,- 359,-EKCMBACIP BMS card (BACnet/IP) € 582,- 582,- 582,- 582,- 582,- 582,-

(1) Preliminary data

(2) Piping between the inertial tank and the unit is not included. Electric heater power supply has to be provided from external source

(3) Some options are not compatible each other. Please contact Daikin Sales Office to know the “incompatibility list” of the above mentioned options

Air cooled heat pump

Applied Systems Price list 2021-2022 27

EWYT-B-XSHigh efficiency rating, standard noise level

ʯ R-32 refrigerant with low GWP. Reduced amount of refrigeranttanks to micro channel heat exchanger technology

ʯ Capacity range from 80kW to 670 kW ʯ Two efficiency level and 3 sound configurations ʯ Two different layouts: parallel coil (standardly equipped with continuous fan speed modulation) and double V coil

ʯ One or two independent refrigerant circuits with two or three compressors

ʯ Extended operating range, hot water up to 60°C ʯ Fully compatible with the Daikin on Site cloud-based platform including remote monitoring, system optimization and preventive maintenance

Air cooled heat pump

Type of unit (rated power in accordance with EN14511) EWYT-B-XS 85 115 135 175 215 215Price € 25.860,- 30.682,- 34.132,- 42.163,- 47.832,- 56.859,-Commissioning by DAIKIN service (net price) € on request on request on request on request on request on requestCooling capacity kW 80 104 126 166 206 206Power input - cooling kW 26,3 35,1 42,1 56,6 71,8 68Heating capacity kW 86 111 133 176 218 215Power input - heating kW 26,1 33,2 39,1 51,7 64,9 62,6Refrigerant circuit 1 1 1 1 1 2Compressors 2 2 2 2 2 4EER 3,03 2,95 2,99 2,93 2,86 3,03SEER 4,24 4,38 4,24 4,45 4,21 4,41COP 3,295 3,345 3,405 3,411 3,363 3,434SCOP 3,70 3,72 3,70 3,75 3,66 3,70Length x Width x Height mm 2.285x1.195x1.800 3.425x1.195x1.800 3.425x1.195x1.800 4.025x1.195x1.800 4.625x1.195x1.800 5.550x1.195x1.800Weight of unit / Operating weight kg 1.080/1.091 1.140/1.151 1.220/1.231 1.400/1.416 1.600/1.616 2.000/2.035Sound power / Sound pressure (at 1m) dB(A) 81,2/63,4 85,6/67,4 87,6/69,4 89,9/71,4 91,4/72,6 88,5/69,2Buffer tank volume / option (OP 134/135/136/137)(1) liter 145 190 190 250 280 280

Optional accessories for chiller:Code Type of unit EWYT-B-XS 85 115 135 175 215 215Mechanical03A Partial heat recovery with control € 1.112,- 1.137,- 1.137,- 1.325,- 1.325,- 2.594,-08 Brine version € on request on request on request on request on request on request20 Evaporator victaulic kit € Standard44 Evaporator area guard € n/a21 Evaporator flange kit € 149,- 149,- 149,- 149,- 149,- 149,-29 20mm evaporator insulation € Standard43 Condenser coil guards € 474,- 518,- 518,- 647,- 763,- 843,-45 Cu-Cu condenser coil € n/a46 Cu-Cu-Sn condenser coil € n/a49 Alucoat fins coil € Standard61 Discharge line shut-off valve € 297,- 297,- 297,- 297,- 297,- 578,-62 Suction line shut-off valve € 490,- 490,- 490,- 490,- 490,- 971,-63 High pressure side manometers € 153,- 153,- 153,- 153,- 153,- 261,-64 Low pressure side manometers € 153,- 153,- 153,- 153,- 153,- 261,-78 One centrifugal pump (low lift) € 2.662,- 2.662,- 2.662,- 2.662,- 3.108,- 3.321,-79 One centrifugal pump (high lift) € 3.108,- 3.108,- 3.108,- 3.108,- 3.132,- 4.201,-80 Two centrifugal pump (low lift) € 3.927,- 3.927,- 3.927,- 4.682,- 4.738,- 5.702,-81 Two centrifugal pump (high lift) € 4.682,- 4.682,- 4.682,- 5.340,- 6.024,- 6.264,-91 Double pressure relief valve with diverter € 943,- 943,- 943,- 943,- 943,- 1.401,-115 Water filter € 265,- 265,- 265,- 265,- 265,- 265,-117 Blygold coil treatment € 3.413,- 4.718,- 4.718,- 5.120,- 5.120,- 5.120,-121 Refrigerant leak detection € 1.032,- 1.032,- 1.032,- 1.032,- 1.032,- 1.032,-134 One centrifugal pump (low lift) + tank € 4.313,- 4.313,- 4.313,- 4.313,- 4.762,- 7.120,-135 One centrifugal pump (high lift) + tank € 4.762,- 4.762,- 4.762,- 5.867,- 5.867,- 8.279,-136 Two centrifugal pump (low lift) + tank € 5.802,- 5.802,- 5.802,- 5.910,- 6.441,- 9.252,-137 Two centrifugal pump (high lift) + tank € 6.441,- 6.441,- 6.441,- 7.256,- 8.095,- 9.714,-

28

Optional accessories for chiller:Code Type of unit EWYT-B-XS 85 115 135 175 215 215Electrical / Control04 Direct on line starter (dol) € Standard06 Soft starter € 2.209,- 2.449,- 2.771,- 3.385,- 3.979,- 4.578,-10 Double setpoint € Standard11 Compressor thermal overload relays € n/a15 Under / over voltage control € 241,- 241,- 241,- 241,- 241,- 241,-16 Energy meter € 1.253,- 1.253,- 1.253,- 1.253,- 1.253,- 1.253,-17 Capacitors for power factor correction € n/a17B Capacitors for power factor correction (single-v) € 494,- 526,- 554,- 662,- 1.048,- 1.048,-42 Speedtrol € n/a57 Evaporator electric heater € Standard58 Evaporator flow switch € 297,- 297,- 297,- 297,- 297,- 297,-60 Electronic expansion valve € Standard

67 Ambient outside temperature sensor and setpoint reset € Standard

68 Hour run meter € Standard69 General fault contactor € Standard70 Alarm from external device € Standard95 Compressors circuit breakers € 305,- 341,- 378,- 466,- 550,- 682,-96 Fans circuit breakers € 177,- 177,- 177,- 177,- 289,- 233,-97 Main switch interlock door € Standard99 Fans speed regulation (+ fan silent mode) € Standard99a Fans speed regulation (vfd) € n/a102 Ground fault relay € n/a114 Nordic kit € 943,- 1.112,- 1.285,- 1.679,- 2.096,- 2.096,-142A High ambient kit € on request on request on request on request on request on request120E Inverter kit for 1 centr pump low lift € 976,- 976,- 976,- 976,- 976,- 999,-120F Inverter kit for 1 centr pump high lift € 999,- 999,- 999,- 999,- n/a120G Inverter kit for 2 centr pump low lift € n/a on request120H Inverter kit for 2 centr pump high lift € n/a120I Inv kit 1 centr pump low lift and tank € on request on request on request on request on request on request120J Inv kit 1 centr pump high lift and tank € 999,- 999,- 999,- 999,- n/a120K Inv kit 2 centr pump low lift and tank € n/a on request120L Inv kit 2 centr pump high lift and tank € n/a128 Master/slave € Standard144 Diff pressure transd (shipped loose) € on request on request on request on request on request on request188 Heating only mode € 345,- 345,- 345,- 345,- 345,- 345,-184 iCM standard € 1.606,- 1.606,- 1.606,- 1.606,- 1.606,- 1.606,-180 Modbus RTU MSTP € 522,- 522,- 522,- 522,- 522,- 522,-181 BACNet MSTP € 522,- 522,- 522,- 522,- 522,- 522,-182 BACNet IP € 522,- 522,- 522,- 522,- 522,- 522,-155 Daikin on site modem (with antenna) € 755,- 755,- 755,- 755,- 755,- 755,-160 100 Pa ESP fan € on request on request on request on request on request on requestInstallation75 Rubber anti vibration mounts € 393,- 393,- 393,- 393,- 393,- 393,-77 Spring anti vibration mounts € 1.221,- 1.221,- 1.221,- 1.221,- 1.221,- 1.221,-83 External tank without cabinet (500 l)(1) € 2.999,- 2.999,- 2.999,- 2.999,- 2.999,- 2.999,-84 External tank without cabinet (1000 l)(1) € 4.003,- 4.003,- 4.003,- 4.003,- 4.003,- 4.003,-87 External tank with cabinet (500 l)(1) € 4.413,- 4.413,- 4.413,- 4.413,- 4.413,- 4.413,-88 External tank with cabinet (1000 l)(1) € 5.649,- 5.649,- 5.649,- 5.649,- 5.649,- 5.649,-Communication cards / AccessoriesEKCMLON BMS card (LonWorks) € 420,- 420,- 420,- 420,- 420,- 420,-EKCM200J BMS Card (ModBus RTU) € 359,- 359,- 359,- 359,- 359,- 359,-EKCMBACIP BMS card (BACnet/IP) € 582,- 582,- 582,- 582,- 582,- 582,-

(1) Preliminary data

(2) Piping between the inertial tank and the unit is not included. Electric heater power supply has to be provided from external source

(3) Some options are not compatible each other. Please contact Daikin Sales Office to know the “incompatibility list” of the above mentioned options

Air cooled heat pump

Applied Systems Price list 2021-2022 29

EWYT-B-XLHigh efficiency rating, low noise level

ʯ R-32 refrigerant with low GWP. Reduced amount of refrigeranttanks to micro channel heat exchanger technology

ʯ Capacity range from 80kW to 670 kW ʯ Two efficiency level and 3 sound configurations ʯ Two different layouts: parallel coil (standardly equipped with continuous fan speed modulation) and double V coil

ʯ One or two independent refrigerant circuits with two or three compressors

ʯ Extended operating range, hot water up to 60°C ʯ Fully compatible with the Daikin on Site cloud-based platform including remote monitoring, system optimization and preventive maintenance

Air cooled heat pump

Type of unit (rated power in accordance with EN14511) EWYT-B-XL 85 115 135 175 215 215Price € 27.120,- 32.011,- 35.135,- 44.314,- 50.414,- 59.830,-Commissioning by DAIKIN service (net price) € on request on request on request on request on request on requestCooling capacity kW 80 104 126 166 206 206Power input - cooling kW 26,3 35,1 42,1 56,6 71,8 68Heating capacity kW 86 111 133 176 218 215Power input - heating kW 26,1 33,2 39,1 51,7 64,9 62,6Refrigerant circuit 1 1 1 1 1 2Compressors 2 2 2 2 2 4EER 3,03 2,95 2,99 2,93 2,86 3,03SEER 4,24 4,24 4,45 4,21 4,41 4,40COP 3,295 3,345 3,405 3,411 3,363 3,434SCOP 3,70 3,72 3,70 3,75 3,66 3,70Length x Width x Height mm 2.285x1.195x1.800 3.425x1.195x1.800 3.425x1.195x1.800 4.025x1.195x1.800 4.625x1.195x1.800 5.550x1.195x1.800Weight of unit / Operating weight kg 1.110/1.121 1.170/1.181 1.250/1.261 1.430/1.446 1.610/1.626 2.030/2.065Sound power / Sound pressure (at 1m) dB(A) 79,5/61,2 84,1/65,4 86,2/67,2 87,5/68,2 85,4/65,6 86,4/66,4Buffer tank volume / option (OP 134/135/136/137)(1) liter 145 190 190 250 280 280

Optional accessories for chiller:Code Type of unit EWYT-B-XL 85 115 135 175 215 215Mechanical03A Partial heat recovery with control € 1.112,- 1.137,- 1.137,- 1.325,- 1.325,- 2.594,-08 Brine version € on request on request on request on request on request on request20 Evaporator victaulic kit € Standard44 Evaporator area guard € n/a21 Evaporator flange kit € 149,- 149,- 149,- 149,- 149,- 149,-29 20mm evaporator insulation € Standard43 Condenser coil guards € 474,- 518,- 518,- 647,- 763,- 843,-45 Cu-Cu condenser coil € n/a46 Cu-Cu-Sn condenser coil € n/a49 Alucoat fins coil € Standard61 Discharge line shut-off valve € 297,- 297,- 297,- 297,- 297,- 578,-62 Suction line shut-off valve € 490,- 490,- 490,- 490,- 490,- 971,-63 High pressure side manometers € 153,- 153,- 153,- 153,- 153,- 261,-64 Low pressure side manometers € 153,- 153,- 153,- 153,- 153,- 261,-78 One centrifugal pump (low lift) € 2.662,- 2.662,- 2.662,- 3.108,- 3.108,- 3.321,-79 One centrifugal pump (high lift) € 3.108,- 3.108,- 3.108,- 3.108,- 3.293,- 4.201,-80 Two centrifugal pump (low lift) € 3.927,- 3.927,- 4.080,- 4.682,- 5.220,- 5.862,-81 Two centrifugal pump (high lift) € 4.682,- 4.682,- 5.340,- 5.983,- 6.104,- 6.264,-91 Double pressure relief valve with diverter € 943,- 943,- 943,- 943,- 943,- 1.401,-115 Water filter € 265,- 265,- 265,- 265,- 361,- 361,-117 Blygold coil treatment € 3.413,- 4.718,- 4.718,- 5.120,- 5.120,- 5.120,-121 Refrigerant leak detection € 1.032,- 1.032,- 1.032,- 1.032,- 1.032,- 1.032,-134 One centrifugal pump (low lift) + tank € 4.313,- 4.313,- 4.313,- 4.762,- 4.762,- 7.120,-135 One centrifugal pump (high lift) + tank € 4.762,- 4.762,- 5.867,- 5.867,- 5.867,- 8.279,-136 Two centrifugal pump (low lift) + tank € 5.802,- 5.802,- 5.910,- 6.441,- 6.441,- 9.252,-137 Two centrifugal pump (high lift) + tank € 6.441,- 6.441,- 7.256,- 8.095,- 8.834,- 9.714,-

30

Optional accessories for chiller:Code Type of unit EWYT-B-XL 85 115 135 175 215 215Electrical / Control04 Direct on line starter (dol) € Standard06 Soft starter € 2.209,- 2.449,- 2.771,- 3.385,- 3.979,- 4.578,-10 Double setpoint € Standard11 Compressor thermal overload relays € n/a15 Under / over voltage control € 241,- 241,- 241,- 241,- 241,- 241,-16 Energy meter € 1.253,- 1.253,- 1.253,- 1.253,- 1.253,- 1.253,-17 Capacitors for power factor correction € n/a17B Capacitors for power factor correction (single-v) € 494,- 526,- 554,- 662,- 1.048,- 1.048,-42 Speedtrol € n/a57 Evaporator electric heater € Standard58 Evaporator flow switch € 297,- 297,- 297,- 297,- 297,- 297,-60 Electronic expansion valve € Standard

67 Ambient outside temperature sensor and setpoint reset € Standard

68 Hour run meter € Standard69 General fault contactor € Standard70 Alarm from external device € Standard95 Compressors circuit breakers € 305,- 341,- 378,- 466,- 550,- 682,-96 Fans circuit breakers € 177,- 177,- 177,- 177,- 289,- 233,-97 Main switch interlock door € Standard99 Fans speed regulation (+ fan silent mode) € Standard99a Fans speed regulation (vfd) € n/a102 Ground fault relay € n/a114 Nordic kit € 943,- 1.112,- 1.285,- 1.679,- 2.096,- 2.096,-142A High ambient kit € on request on request on request on request on request on request120E Inverter kit for 1 centr pump low lift € 976,- 976,- 976,- 976,- 976,- 999,-120F Inverter kit for 1 centr pump high lift € 999,- 999,- 999,- 999,- n/a120G Inverter kit for 2 centr pump low lift € n/a 2.108,-120H Inverter kit for 2 centr pump high lift € n/a120I Inv kit 1 centr pump low lift and tank € 976,- 976,- 976,- 976,- 976,- 999,-120J Inv kit 1 centr pump high lift and tank € 999,- 999,- 999,- 999,- n/a120K Inv kit 2 centr pump low lift and tank € n/a 2.108,-120L Inv kit 2 centr pump high lift and tank € n/a128 Master/slave € Standard144 Diff pressure transd (shipped loose) € on request on request on request on request on request on request188 Heating only mode € 345,- 345,- 345,- 345,- 345,- 345,-184 iCM standard € 1.606,- 1.606,- 1.606,- 1.606,- 1.606,- 1.606,-180 Modbus RTU MSTP € 522,- 522,- 522,- 522,- 522,- 522,-181 BACNet MSTP € 522,- 522,- 522,- 522,- 522,- 522,-182 BACNet IP € 522,- 522,- 522,- 522,- 522,- 522,-155 Daikin on site modem (with antenna) € 755,- 755,- 755,- 755,- 755,- 755,-160 100 Pa ESP fan € on request on request on request on request on request on requestInstallation75 Rubber anti vibration mounts € 393,- 393,- 393,- 393,- 393,- 393,-77 Spring anti vibration mounts € 1.221,- 1.221,- 1.221,- 1.221,- 1.221,- 1.221,-83 External tank without cabinet (500 l)(1) € 2.999,- 2.999,- 2.999,- 2.999,- 2.999,- 2.999,-84 External tank without cabinet (1000 l)(1) € 4.003,- 4.003,- 4.003,- 4.003,- 4.003,- 4.003,-87 External tank with cabinet (500 l)(1) € 4.413,- 4.413,- 4.413,- 4.413,- 4.413,- 4.413,-88 External tank with cabinet (1000 l)(1) € 5.649,- 5.649,- 5.649,- 5.649,- 5.649,- 5.649,-Communication cards / AccessoriesEKCMLON BMS card (LonWorks) € 420,- 420,- 420,- 420,- 420,- 420,-EKCM200J BMS Card (ModBus RTU) € 359,- 359,- 359,- 359,- 359,- 359,-EKCMBACIP BMS card (BACnet/IP) € 582,- 582,- 582,- 582,- 582,- 582,-

(1) Preliminary data

(2) Piping between the inertial tank and the unit is not included. Electric heater power supply has to be provided from external source

(3) Some options are not compatible each other. Please contact Daikin Sales Office to know the “incompatibility list” of the above mentioned options

Air cooled heat pump

Applied Systems Price list 2021-2022 31

EWYT-B-XRHigh efficiency rating, reduced noise level

ʯ R-32 refrigerant with low GWP. Reduced amount of refrigeranttanks to micro channel heat exchanger technology

ʯ Capacity range from 80kW to 670 kW ʯ Two efficiency level and 3 sound configurations ʯ Two different layouts: parallel coil (standardly equipped with continuous fan speed modulation) and double V coil

ʯ One or two independent refrigerant circuits with two or three compressors

ʯ Extended operating range, hot water up to 60°C ʯ Fully compatible with the Daikin on Site cloud-based platform including remote monitoring, system optimization and preventive maintenance

Air cooled heat pump

Type of unit (rated power in accordance with EN14511) EWYT-B-XR 85 115 135 175 215 215Price € 27.823,- 32.814,- 36.460,- 45.483,- 51.896,- 61.662,-Commissioning by DAIKIN service (net price) € on request on request on request on request on request on requestCooling capacity kW 79 103 124 164 203 204Power input - cooling kW 26,6 35,4 42,6 57,4 72,9 68,8Heating capacity kW 85 110 132 174 217 213Power input - heating kW 25,9 32,9 38,8 51,3 64,5 62,1Refrigerant circuit 1 1 1 1 1 2Compressors 2 2 2 2 2 4EER 2,98 2,90 2,92 2,86 2,79 2,97SEER 4,21 4,37 4,21 4,41 4,16 4,42COP 3,282 3,349 3,401 3,394 3,357 3,436SCOP 3,66 3,71 3,72 3,83 3,74 3,75Length x Width x Height mm 2.285x1.195x1.800 3.425x1.195x1.800 3.425x1.195x1.800 4.025x1.195x1.800 4.625x1.195x1.800 5.550x1.195x1.800Weight of unit / Operating weight kg 1.110/1.121 1.170/1.181 1.250/1.261 1.430/1.446 1.610/1.626 2.030/2.065Sound power / Sound pressure (at 1m) dB(A) 77,1/59,3 81,0/62,8 82,9/64,7 85,1/66,6 86,5/67,7 83,9/64,6Buffer tank volume / option (OP 134/135/136/137)(1) liter 145 190 190 250 280 280

Optional accessories for chiller:Code Type of unit EWYT-B-XR 85 115 135 175 215 215Mechanical03A Partial heat recovery with control € on request on request on request on request on request on request08 Brine version € on request on request on request on request on request on request20 Evaporator victaulic kit € Standard44 Evaporator area guard € n/a21 Evaporator flange kit € 149,- 149,- 149,- 149,- 149,- 149,-29 20mm evaporator insulation € Standard43 Condenser coil guards € 474,- 518,- 518,- 647,- 763,- 843,-45 Cu-Cu condenser coil € n/a46 Cu-Cu-Sn condenser coil € n/a49 Alucoat fins coil € Standard61 Discharge line shut-off valve € 297,- 297,- 297,- 297,- 297,- 578,-62 Suction line shut-off valve € 490,- 490,- 490,- 490,- 490,- 971,-63 High pressure side manometers € 153,- 153,- 153,- 153,- 153,- 261,-64 Low pressure side manometers € 153,- 153,- 153,- 153,- 153,- 261,-78 One centrifugal pump (low lift) € 2.662,- 2.662,- 2.662,- 3.108,- 3.108,- 3.321,-79 One centrifugal pump (high lift) € 3.108,- 3.108,- 3.108,- 3.108,- 3.293,- 4.201,-80 Two centrifugal pump (low lift) € 3.927,- 3.927,- 4.080,- 4.682,- 5.220,- 5.862,-81 Two centrifugal pump (high lift) € 4.682,- 4.682,- 5.340,- 5.983,- 6.104,- 6.264,-91 Double pressure relief valve with diverter € 943,- 943,- 943,- 943,- 943,- 1.401,-115 Water filter € 265,- 265,- 265,- 265,- 361,- 361,-117 Blygold coil treatment € 3.413,- 4.718,- 4.718,- 5.120,- 5.120,- 5.120,-121 Refrigerant leak detection € 1.032,- 1.032,- 1.032,- 1.032,- 1.032,- 1.032,-134 One centrifugal pump (low lift) + tank € 4.313,- 4.313,- 4.313,- 4.762,- 4.762,- 7.120,-135 One centrifugal pump (high lift) + tank € 4.762,- 4.762,- 5.867,- 5.867,- 5.867,- 8.279,-136 Two centrifugal pump (low lift) + tank € 5.802,- 5.802,- 5.910,- 6.441,- 6.441,- 9.252,-137 Two centrifugal pump (high lift) + tank € 6.441,- 6.441,- 7.256,- 8.095,- 8.834,- 9.714,-

32

Optional accessories for chiller:Code Type of unit EWYT-B-XR 85 115 135 175 215 215Electrical / Control04 Direct on line starter (dol) € Standard06 Soft starter € 2.209,- 2.449,- 2.771,- 3.385,- 3.979,- 4.578,-10 Double setpoint € Standard11 Compressor thermal overload relays € n/a15 Under / over voltage control € 241,- 241,- 241,- 241,- 241,- 241,-16 Energy meter € 1.253,- 1.253,- 1.253,- 1.253,- 1.253,- 1.253,-17 Capacitors for power factor correction € n/a17B Capacitors for power factor correction (single-v) € 494,- 526,- 554,- 662,- 1.048,- 1.048,-42 Speedtrol € n/a57 Evaporator electric heater € Standard58 Evaporator flow switch € 297,- 297,- 297,- 297,- 297,- 297,-60 Electronic expansion valve € Standard

67 Ambient outside temperature sensor and setpoint reset € Standard

68 Hour run meter € Standard69 General fault contactor € Standard70 Alarm from external device € Standard95 Compressors circuit breakers € 305,- 341,- 378,- 466,- 550,- 682,-96 Fans circuit breakers € 177,- 177,- 177,- 177,- 289,- 233,-97 Main switch interlock door € Standard99 Fans speed regulation (+ fan silent mode) € Standard99a Fans speed regulation (vfd) € n/a102 Ground fault relay € n/a114 Nordic kit € 943,- 1.112,- 1.285,- 1.679,- 2.096,- 2.096,-142A High ambient kit € on request on request on request on request on request on request120E Inverter kit for 1 centr pump low lift € 976,- 976,- 976,- 976,- 976,- 999,-120F Inverter kit for 1 centr pump high lift € 999,- 999,- 999,- 999,- n/a120G Inverter kit for 2 centr pump low lift € n/a 2.108,-120H Inverter kit for 2 centr pump high lift € n/a120I Inv kit 1 centr pump low lift and tank € 976,- 976,- 976,- 976,- 976,- 999,-120J Inv kit 1 centr pump high lift and tank € 999,- 999,- 999,- 999,- n/a120K Inv kit 2 centr pump low lift and tank € n/a 2.108,-120L Inv kit 2 centr pump high lift and tank € n/a128 Master/slave € Standard144 Diff pressure transd (shipped loose) € on request on request on request on request on request on request188 Heating only mode € 345,- 345,- 345,- 345,- 345,- 345,-184 iCM standard € 1.606,- 1.606,- 1.606,- 1.606,- 1.606,- 1.606,-180 Modbus RTU MSTP € 522,- 522,- 522,- 522,- 522,- 522,-181 BACNet MSTP € 522,- 522,- 522,- 522,- 522,- 522,-182 BACNet IP € 522,- 522,- 522,- 522,- 522,- 522,-155 Daikin on site modem (with antenna) € 755,- 755,- 755,- 755,- 755,- 755,-Installation75 Rubber anti vibration mounts € 393,- 393,- 393,- 393,- 393,- 393,-77 Spring anti vibration mounts € 1.221,- 1.221,- 1.221,- 1.221,- 1.221,- 1.221,-83 External tank without cabinet (500 l)(1) € 2.999,- 2.999,- 2.999,- 2.999,- 2.999,- 2.999,-84 External tank without cabinet (1000 l)(1) € 4.003,- 4.003,- 4.003,- 4.003,- 4.003,- 4.003,-87 External tank with cabinet (500 l)(1) € 4.413,- 4.413,- 4.413,- 4.413,- 4.413,- 4.413,-88 External tank with cabinet (1000 l)(1) € 5.649,- 5.649,- 5.649,- 5.649,- 5.649,- 5.649,-Communication cards / AccessoriesEKCMLON BMS card (LonWorks) € 420,- 420,- 420,- 420,- 420,- 420,-EKCM200J BMS Card (ModBus RTU) € 359,- 359,- 359,- 359,- 359,- 359,-EKCMBACIP BMS card (BACnet/IP) € 582,- 582,- 582,- 582,- 582,- 582,-

(1) Preliminary data

(2) Piping between the inertial tank and the unit is not included. Electric heater power supply has to be provided from external source

(3) Some options are not compatible each other. Please contact Daikin Sales Office to know the “incompatibility list” of the above mentioned options

Air cooled heat pump

Applied Systems Price list 2021-2022 33

ARGUE CARDS

EWAT-B- Multi scroll Air cooled chillerwith R-32 refrigerant

Single V

Modular V

EWAT-B- at a glance

• Wide capacity range: 80 – 700 kW

• Silver and Gold efficiency versions

• 3 sound configurations

• Full compatibility with Daikin on Site

• New Hydronic Kit configurations

(single and twin pump, inertial tank, VFD)

• Single and dual circuit version overlapping between 150 kW and 350 kW

• Extensive option lists

• Fan speed modulation option (VFD)

34

Air cooled chiller

Type of unit (rated power in accordance with EN14511) EWAT -B-SS 85 115 135 155 175 195 205Price € 18.720,- 22.222,- 24.849,- 31.137,- 29.544,- 36.158,- 39.718,-Commissioning by DAIKIN service (net price) € on request on request on request on request on request on request on requestCooling capacity kW 81 109 131 158 175 191 211Power input kW 31,8 38,5 49,8 61,8 67,8 69,5 80Refrigerant circuit 1 1 1 2 1 2 2Compressors 2 2 2 4 2 4 4EER 2,55 2,83 2,64 2,55 2,58 2,75 2,63SEER(+opt FANMOD)(2) 4,10 4,40 4,10 4,10 4,48 4,34 4,40Length x Width x Height mm 2.120x1.204x1.801 2.650 x1.204x1.801 2.650x1.204x1.801 3.570x1.204x1.822 3.170x1.204x1.801 4.170x1.204x1.822 4.170x1.204x1.822Weight of unit / Operating weight kg 681/686 767/777 811/821 1.007/1.014 984/996 1.166/1.177 1.158/1.169Sound power / Sound pressure (at 1m) dB(A) 85/67 88/71 90/72 88/70 92/74 90/71 91/72Buffer tank volume / option (OP 134/135/136/137) liter 50 145 145 190 190 250 250

Optional accessories for chiller:Code Type of unit EWAT -B-SS 85 115 135 155 175 195 205Mechanical01 Total heat recovery €

n/a 3.417,- 4.344,- 5.305,- 5.305,- 6.191,- 6.893,-

03A Partial heat recovery with control € 1.383,- 1.847,- 2.548,- 1.847,- 2.548,- 2.548,-08 Brine version € 285,- 285,- 285,- 285,- 285,- 285,- 285,-20 Evaporator victaulic kit € Standard21 Evaporator flange kit € 151,- 151,- 151,- 151,- 151,- 151,- 151,-29 20mm evaporator insulation € 285,- 285,- 285,- 285,- 285,- 285,- 285,-78 One centrifugal pump (low lift) € 2.352,- 2.456,- 2.456,- 2.610,- 2.610,- 2.715,- 2.715,-79 One centrifugal pump (high lift) € 2.870,- 2.979,- 2.979,- 2.979,- 2.979,- 3.167,- 3.167,-80 Two centrifugal pump (low lift) € 3.885,- 3.885,- 3.885,- 4.002,- 4.002,- 4.161,- 4.161,-81 Two centrifugal pump (high lift) € 4.557,- 4.650,- 4.650,- 4.650,- 4.650,- 4.775,- 4.775,-91 Double pressure relief valve with diverter € 961,- 961,- 961,- 1.428,- 961,- 1.428,- 1.428,-115 Water filter € 267,- 267,- 267,- 321,- 267,- 321,- 321,-121 Refrigerant leak detection € 1.048,- 1.048,- 1.048,- 1.048,- 1.048,- 1.048,- 1.048,-126 Discharge and suction line shut-off valve € 802,- 802,- 802,- 1.605,- 802,- 1.605,- 1.605,-127 High and low pressure side manometers € 263,- 263,- 263,- 526,- 263,- 526,- 526,-134 One centrifugal pump (low lift) + tank € 3.697,- 4.135,- 4.135,- 4.299,- 4.299,- 4.395,- 4.395,-135 One centrifugal pump (high lift) + tank € 4.220,- 4.666,- 4.666,- 4.666,- 4.666,- 4.854,- 4.854,-136 Two centrifugal pump (low lift) + tank € 5.756,- 5.832,- 5.832,- 5.916,- 5.916,- 6.028,- 6.028,-137 Two centrifugal pump (high lift) + tank € 6.292,- 6.384,- 6.384,- 6.384,- 6.384,- 6.567,- 6.567,-139 E-coating microchannel coils € 802,- 1.203,- 1.203,- 1.605,- 1.605,- 2.005,- 2.005,-140 Unit guards (to cover unit access) € 460,- 501,- 501,- 543,- 543,- 586,- 586,-Electrical / Control04 Direct on line starter (dol) € Standard 06 Soft starter € 1.876,- 2.222,- 2.486,- 3.116,- 2.958,- 3.618,- 3.973,-10 Double setpoint € Standard 15 Under / over voltage control € 242,- 242,- 242,- 242,- 242,- 242,- 242,-16 Energy meter € on request on request on request 1.275,- on request 1.275,- 1.275,-17B Capacitors for power factor correction (single-v) € 501,- 534,- 565,- 1.003,- 675,- 1.035,- 1.066,-57 Evaporator electric heater € Standard 58 Evaporator flow switch € 301,- 301,- 301,- 301,- 301,- 301,- 301,-

EWAT-B-SSStandard efficiency rating, standard noise level

ʯ R-32 refrigerant with low GWP. Reduced amount of refrigerant tanks to micro channel heat exchanger technology

ʯ One or two independent refrigerant circuits (2 or 4 scroll compressors) with single evaporator

ʯ Wide capacity range: 80 - 700 kW (“Single V” layout up to 210 kW, “Multi V” layout up to 700 kW)

ʯ Two efficiency level and 3 sound configurations Free cooling migration options available for Multi V models(1)

ʯ Partial and total heat recovery option available ʯ Stainless steel plate heat exchanger optimized for R-32 refrigerant operation

Applied Systems Price list 2021-2022 35

Air cooled chiller

Installation75 Rubber anti vibration mounts € 393,- 393,- 393,- 393,- 393,- 393,- 393,-77 Spring anti vibration mounts € 1.237,- 1.237,- 1.237,- 1.237,- 1.237,- 1.237,- 1.237,-83 External tank without cabinet (500 l) € 3.058,- 3.058,- 3.058,- 3.058,- 3.058,- 3.058,- 3.058,-84 External tank without cabinet (1000 l) € 4.081,- 4.081,- 4.081,- 4.081,- 4.081,- 4.081,- 4.081,-87 External tank with cabinet (500 l) € 4.499,- 4.499,- 4.499,- 4.499,- 4.499,- 4.499,- 4.499,-88 External tank with cabinet (1000 l) € 5.761,- 5.761,- 5.761,- 5.761,- 5.761,- 5.761,- 5.761,-Communication cards / AccessoriesEKCM200J BMS card (ModBUS-RTU) € 359,- 359,- 359,- 359,- 359,- 359,- 359,-EKCMBACMSTP BMS card (BacNet/ MSTP) € 431,- 431,- 431,- 431,- 431,- 431,- 431,-EKCMLON BMS card (LonWorks) € 420,- 420,- 420,- 420,- 420,- 420,- 420,-EKCMBACIP BMS card (BACnet/IP) € 582,- 582,- 582,- 582,- 582,- 582,- 582,-

(1) Check the databook for Multi V models; (2) Option FANMOD consist in Continuous Fan Speed Regulation and improves part load operation, Single-V units are standardly equipped with continuous fan control, Modular-V units require opt 99a – VFD fans

Optional accessories for chiller:

Code Type of unit EWAT -B-SS 85 115 135 155 175 195 20560 Electronic expansion valve €

Standard67 Ambient outside temperature sensor and setpoint reset €68 Hour run meter €69 General fault contactor €70 Alarm from external device €95 Compressors circuit breakers € 310,- 346,- 384,- 618,- 472,- 655,- 694,-96 Fans circuit breakers € 180,- 180,- 180,- 180,- 180,- 180,- 180,-97 Main switch interlock door €

Standard 99 Fans speed regulation (+ fan silent mode) €120e Inverter kit for 1 centr pump low lift € 795,- 860,- 860,- 994,- 994,- 994,- 994,-120f Inverter kit for 1 centr pump high lift € 994,- 994,- 994,- 994,- 994,- 994,- 994,-128 Master/slave € Standard142A High ambient kit € 601,- 760,- 760,- 918,- 918,- 1.077,- 1.077,-143 Variable primary flow € Contact Factory144 Diff pressure transd (shipped loose) € 1.457,- 1.457,- 1.457,- 1.457,- 1.457,- 1.457,- 1.457,-184 iCM standard € on request on request on request on request on request on request on request180 Modbus RTU MSTP € on request on request on request on request on request on request on request181 BACNet MSTP € on request on request on request on request on request on request on request182 BACNet IP € on request on request on request on request on request on request on request155 Daikin on site modem (with antenna) € 769,- 769,- 769,- 769,- 769,- 769,- 769,-160 100 pa esp fans € 350,- 510,- 510,- 669,- 669,- 827,- 827,-

36

EWAT-B-SLStandard efficiency rating, low noise level

ʯ R-32 refrigerant with low GWP. Reduced amount of refrigerant tanks to micro channel heat exchanger technology

ʯ One or two independent refrigerant circuits (2 or 4 scroll compressors) with single evaporator

ʯ Wide capacity range: 80 - 700 kW (“Single V” layout up to 210 kW, “Multi V” layout up to 700 kW)

ʯ Two efficiency level and 3 sound configurations Free cooling migration options available for Multi V models(1)

ʯ Partial and total heat recovery option available ʯ Stainless steel plate heat exchanger optimized for R-32 refrigerant operation

Air cooled chiller

Type of unit (rated power in accordance with EN14511) EWAT -B-SL 85 115 135 155 175 195 205Price € 19.096,- 22.668,- 25.346,- 31.763,- 30.137,- 36.885,- 40.515,-Commissioning by DAIKIN service (net price) € on request on request on request on request on request on request on requestCooling capacity kW 81 109 131 158 175 191 211Power input kW 31,8 38,5 49,8 61,9 67,7 69,5 80Refrigerant circuit 1 1 1 2 1 2 2Compressors 2 2 2 4 2 4 4EER 2,55 2,83 2,64 2,55 2,58 2,75 2,63SEER (+opt FANMOD)(1) 4,10 4,40 4,10 4,10 4,48 4,34 4,40Length x Width x Height mm 2.120x1.204x1.801 2.650x1.204x1.801 2.650x1.204x1.801 3.570x1.204x1.822 3.170x1.204x1.801 4.170x1.204x1.822 4.170x1.204x1.822Weight of unit / Operating weight kg 691/696 777/783 820/830 1.028/1.035 994/1.006 1.087/1.198 1.179/1.190Sound power / Sound pressure (at 1m) dB(A) 84/66 86/69 87/69 87/68 89/71 88/70 89/70Buffer tank volume / option (OP 134/135/136/137) liter 50 145 145 190 190 250 250

Optional accessories for chiller:Code Type of unit EWAT -B-SL 85 115 135 155 175 195 205Mechanical01 Total heat recovery €

n/a 3.417,- 4.344,- 5.305,- 5.305,- 6.191,- 6.893,-

03A Partial heat recovery with control € 1.383,- 1.847,- 2.548,- 1.847,- 2.548,- 2.548,-08 Brine version € 285,- 285,- 285,- 285,- 285,- 285,- 285,-20 Evaporator victaulic kit € Standard21 Evaporator flange kit € 151,- 151,- 151,- 151,- 151,- 151,- 151,-29 20mm evaporator insulation € 285,- 285,- 285,- 285,- 285,- 285,- 285,-78 One centrifugal pump (low lift) € 2.352,- 2.456,- 2.456,- 2.610,- 2.610,- 2.715,- 2.715,-79 One centrifugal pump (high lift) € 2.870,- 2.979,- 2.979,- 2.979,- 2.979,- 3.167,- 3.167,-80 Two centrifugal pump (low lift) € 3.885,- 3.885,- 3.885,- 4.002,- 4.002,- 4.161,- 4.161,-81 Two centrifugal pump (high lift) € 4.557,- 4.650,- 4.650,- 4.650,- 4.650,- 4.775,- 4.775,-91 Double pressure relief valve with diverter € 961,- 961,- 961,- 1.428,- 961,- 1.428,- 1.428,-115 Water filter € 267,- 267,- 267,- 321,- 267,- 321,- 321,-121 Refrigerant leak detection € 1.048,- 1.048,- 1.048,- 1.048,- 1.048,- 1.048,- 1.048,-126 Discharge and suction line shut-off valve € 802,- 802,- 802,- 1.605,- 802,- 1.605,- 1.605,-127 High and low pressure side manometers € 263,- 263,- 263,- 526,- 263,- 526,- 526,-134 One centrifugal pump (low lift) + tank € 3.697,- 4.135,- 4.135,- 4.299,- 4.299,- 4.395,- 4.395,-135 One centrifugal pump (high lift) + tank € 4.220,- 4.666,- 4.666,- 4.666,- 4.666,- 4.854,- 4.854,-136 Two centrifugal pump (low lift) + tank € 5.756,- 5.832,- 5.832,- 5.916,- 5.916,- 6.028,- 6.028,-137 Two centrifugal pump (high lift) + tank € 6.292,- 6.384,- 6.384,- 6.384,- 6.384,- 6.567,- 6.567,-139 E-coating microchannel coils € 802,- 1.203,- 1.203,- 1.605,- 1.605,- 2.005,- 2.005,-140 Unit guards (to cover unit access) € 460,- 501,- 501,- 543,- 543,- 586,- 586,-Electrical / Control04 Direct on line starter (dol) € Standard 06 Soft starter € 1.876,- 2.222,- 2.486,- 3.116,- 2.958,- 3.618,- 3.973,-10 Double setpoint € Standard 15 Under / over voltage control € 242,- 242,- 242,- 242,- 242,- 242,- 242,-16 Energy meter € on request on request on request 1.275,- on request 1.275,- 1.275,-17B Capacitors for power factor correction (single-v) € 501,- 534,- 565,- 1.003,- 675,- 1.035,- 1.066,-57 Evaporator electric heater € Standard 58 Evaporator flow switch € 301,- 301,- 301,- 301,- 301,- 301,- 301,-60 Electronic expansion valve €

Standard67 Ambient outside temperature sensor and setpoint reset €68 Hour run meter €69 General fault contactor €70 Alarm from external device €

Applied Systems Price list 2021-2022 37

Air cooled chiller

Optional accessories for chiller:

Code Type of unit EWAT -B-SL 85 115 135 155 175 195 20595 Compressors circuit breakers € 310,- 346,- 384,- 618,- 472,- 655,- 694,-96 Fans circuit breakers € 180,- 180,- 180,- 180,- 180,- 180,- 180,-97 Main switch interlock door €

Standard99 Fans speed regulation (+ fan silent mode) €120e Inverter kit for 1 centr pump low lift € 795,- 860,- 860,- 994,- 994,- 994,- 994,-120f Inverter kit for 1 centr pump high lift € 994,- 994,- 994,- 994,- 994,- 994,- 994,-128 Master/slave € Standard142A High ambient kit € 601,- 760,- 760,- Contact Factory 918,- 1.077,- 1.077,-143 Variable primary flow € Contact Factory144 Diff pressure transd (shipped loose) € 1.457,- 1.457,- 1.457,- 1.457,- 1.457,- 1.457,- 1.457,-184 iCM standard € on request on request on request on request on request on request on request180 Modbus RTU MSTP € on request on request on request on request on request on request on request181 BACNet MSTP € on request on request on request on request on request on request on request182 BACNet IP € on request on request on request on request on request on request on request155 Daikin on site modem (with antenna) € 769,- 769,- 769,- 769,- 769,- 769,- 769,-160 100 pa esp fans € 350,- 510,- 510,- 669,- 669,- 827,- 827,-Installation75 Rubber anti vibration mounts € 393,- 393,- 393,- 393,- 393,- 393,- 393,-77 Spring anti vibration mounts € 1.237,- 1.237,- 1.237,- 1.237,- 1.237,- 1.237,- 1.237,-83 External tank without cabinet (500 l) € 3.058,- 3.058,- 3.058,- 3.058,- 3.058,- 3.058,- 3.058,-84 External tank without cabinet (1000 l) € 4.081,- 4.081,- 4.081,- 4.081,- 4.081,- 4.081,- 4.081,-87 External tank with cabinet (500 l) € 4.499,- 4.499,- 4.499,- 4.499,- 4.499,- 4.499,- 4.499,-88 External tank with cabinet (1000 l) € 5.761,- 5.761,- 5.761,- 5.761,- 5.761,- 5.761,- 5.761,-Communication cards / AccessoriesEKCM200J BMS card (ModBUS-RTU) € 359,- 359,- 359,- 359,- 359,- 359,- 359,-EKCMBACMSTP BMS card (BacNet/ MSTP) € 431,- 431,- 431,- 431,- 431,- 431,- 431,-EKCMLON BMS card (LonWorks) € 420,- 420,- 420,- 420,- 420,- 420,- 420,-EKCMBACIP BMS card (BACnet/IP) € 582,- 582,- 582,- 582,- 582,- 582,- 582,-

(1) Option FANMOD consist in Continuous Fan Speed Regulation and improves part load operation, Single-V units are standardly equipped with continuous fan control, Modular-V units require opt 99a – VFD fans

38

EWAT-B-SRStandard efficiency rating, reduced noise level

ʯ R-32 refrigerant with low GWP. Reduced amount of refrigerant tanks to micro channel heat exchanger technology

ʯ One or two independent refrigerant circuits (2 or 4 scroll compressors) with single evaporator

ʯ Wide capacity range: 80 - 700 kW (“Single V” layout up to 210 kW, “Multi V” layout up to 700 kW)

ʯ Two efficiency level and 3 sound configurations Free cooling migration options available for Multi V models(1)

ʯ Partial and total heat recovery option available ʯ Stainless steel plate heat exchanger optimized for R-32 refrigerant operation

Air cooled chiller

Type of unit (rated power in accordance with EN14511) EWAT -B-SR 85 115 135 155 175 195 205Price € 19.673,- 23.349,- 26.110,- 32.719,- 31.044,- 37.992,- 41.731,-Commissioning by DAIKIN service (net price) € on request on request on request on request on request on request on requestCooling capacity kW 76 105 124 150 165 181 201Power input kW 33,7 40,3 53 65,9 73 73,2 84,6Refrigerant circuit 1 1 1 2 1 2 2Compressors 2 2 2 4 2 4 4EER 2,27 2,61 2,34 2,28 2,26 2,48 2,37SEER (+opt FANMOD)(1) 4,10 4,40 4,10 4,10 4,23 4,13 4,27Length x Width x Height mm 2.120x1.204x1.801 2.650x1.204x1.801 2.650x1.204x1.801 3.570x1.204x1.822 3.170x1.204x1.801 4.170x1.204x1.822 4.170x1.204x1.822Weight of unit / Operating weight kg 691/696 777/783 821/830 1.028/1.035 994/1.006 1.187/1.198 1.179/1.190Sound power / Sound pressure (at 1m) dB(A) 77/61 83/65 84/66 82/63 86/68 84/65 85/67Buffer tank volume / option (OP 134/135/136/137) liter 50 145 145 190 190 250 250

Optional accessories for chiller:Code Type of unit EWAT -B-SR 85 115 135 155 175 195 205Mechanical01 Total heat recovery €

n/a 3.417,- 4.344,- 5.305,- 5.305,- 6.191,- 6.893,-

03A Partial heat recovery with control € 1.383,- 1.847,- 2.548,- 1.847,- 2.548,- 2.548,-08 Brine version € 285,- 285,- 285,- 285,- 285,- 285,- 285,-20 Evaporator victaulic kit € Standard21 Evaporator flange kit € 151,- 151,- 151,- 151,- 151,- 151,- 151,-29 20mm evaporator insulation € 285,- 285,- 285,- 285,- 285,- 285,- 285,-78 One centrifugal pump (low lift) € 2.352,- 2.456,- 2.456,- 2.610,- 2.610,- 2.715,- 2.715,-79 One centrifugal pump (high lift) € 2.870,- 2.979,- 2.979,- 2.979,- 2.979,- 3.167,- 3.167,-80 Two centrifugal pump (low lift) € 3.885,- 3.885,- 3.885,- 4.002,- 4.002,- 4.161,- 4.161,-81 Two centrifugal pump (high lift) € 4.557,- 4.650,- 4.650,- 4.650,- 4.650,- 4.775,- 4.775,-91 Double pressure relief valve with diverter € 961,- 961,- 961,- 1.428,- 961,- 1.428,- 1.428,-115 Water filter € 267,- 267,- 267,- 321,- 267,- 321,- 321,-121 Refrigerant leak detection € 1.048,- 1.048,- 1.048,- 1.048,- 1.048,- 1.048,- 1.048,-126 Discharge and suction line shut-off valve € 802,- 802,- 802,- 1.605,- 802,- 1.605,- 1.605,-127 High and low pressure side manometers € 263,- 263,- 263,- 526,- 263,- 526,- 526,-134 One centrifugal pump (low lift) + tank € 3.697,- 4.135,- 4.135,- 4.299,- 4.299,- 4.395,- 4.395,-135 One centrifugal pump (high lift) + tank € 4.220,- 4.666,- 4.666,- 4.666,- 4.666,- 4.854,- 4.854,-136 Two centrifugal pump (low lift) + tank € 5.756,- 5.832,- 5.832,- 5.916,- 5.916,- 6.028,- 6.028,-137 Two centrifugal pump (high lift) + tank € 6.292,- 6.384,- 6.384,- 6.384,- 6.384,- 6.567,- 6.567,-139 E-coating microchannel coils € 802,- 1.203,- 1.203,- 1.605,- 1.605,- 2.005,- 2.005,-140 Unit guards (to cover unit access) € 460,- 501,- 501,- 543,- 543,- 586,- 586,-Electrical / Control04 Direct on line starter (dol) € Standard 06 Soft starter € 1.876,- 2.222,- 2.486,- 3.116,- 2.958,- 3.618,- 3.973,-10 Double setpoint € Standard 15 Under / over voltage control € 242,- 242,- 242,- 242,- 242,- 242,- 242,-16 Energy meter € on request on request on request 1.275,- on request 1.275,- 1.275,-17B Capacitors for power factor correction (single-v) € 501,- 534,- 565,- 1.003,- 675,- 1.035,- 1.066,-57 Evaporator electric heater € Standard 58 Evaporator flow switch € 301,- 301,- 301,- 301,- 301,- 301,- 301,-60 Electronic expansion valve €

Standard67 Ambient outside temperature sensor and setpoint reset €68 Hour run meter €69 General fault contactor €70 Alarm from external device €

Applied Systems Price list 2021-2022 39

Air cooled chiller

Optional accessories for chiller:

Code Type of unit EWAT -B-SR 85 115 135 155 175 195 20595 Compressors circuit breakers € 310,- 346,- 384,- 618,- 472,- 655,- 694,-96 Fans circuit breakers € 180,- 180,- 180,- 180,- 180,- 180,- 180,-97 Main switch interlock door €

Standard 99 Fans speed regulation (+ fan silent mode) €120e Inverter kit for 1 centr pump low lift € 795,- 860,- 860,- 994,- 994,- 994,- 994,-120f Inverter kit for 1 centr pump high lift € 994,- 994,- 994,- 994,- 994,- 994,- 994,-128 Master/slave € Standard142A High ambient kit € Contact factory 760,- Contact factory 918,- 1.077,- 1.077,-143 Variable primary flow € Contact factory144 Diff pressure transd (shipped loose) € 1.457,- 1.457,- 1.457,- 1.457,- 1.457,- 1.457,- 1.457,-184 iCM standard € on request on request on request on request on request on request on request180 Modbus RTU MSTP € on request on request on request on request on request on request on request181 BACNet MSTP € on request on request on request on request on request on request on request182 BACNet IP € on request on request on request on request on request on request on request155 Daikin on site modem (with antenna) € 769,- 769,- 769,- 769,- 769,- 769,- 769,-Installation75 Rubber anti vibration mounts € 393,- 393,- 393,- 393,- 393,- 393,- 393,-77 Spring anti vibration mounts € 1.237,- 1.237,- 1.237,- 1.237,- 1.237,- 1.237,- 1.237,-83 External tank without cabinet (500 l) € 3.058,- 3.058,- 3.058,- 3.058,- 3.058,- 3.058,- 3.058,-84 External tank without cabinet (1000 l) € 4.081,- 4.081,- 4.081,- 4.081,- 4.081,- 4.081,- 4.081,-87 External tank with cabinet (500 l) € 4.499,- 4.499,- 4.499,- 4.499,- 4.499,- 4.499,- 4.499,-88 External tank with cabinet (1000 l) € 5.761,- 5.761,- 5.761,- 5.761,- 5.761,- 5.761,- 5.761,-Communication cards / AccessoriesEKCM200J BMS card (ModBUS-RTU) € 359,- 359,- 359,- 359,- 359,- 359,- 359,-EKCMBACMSTP BMS card (BacNet/ MSTP) € 431,- 431,- 431,- 431,- 431,- 431,- 431,-EKCMLON BMS card (LonWorks) € 420,- 420,- 420,- 420,- 420,- 420,- 420,-EKCMBACIP BMS card (BACnet/IP) € 582,- 582,- 582,- 582,- 582,- 582,- 582,-

(1) Option FANMOD consist in Continuous Fan Speed Regulation and improves part load operation, Single-V units are standardly equipped with continuous fan control, Modular-V units require opt 99a – VFD fans

40

EWAT-B-XSHigh efficiency rating, standard noise level

ʯ R-32 refrigerant with low GWP. Reduced amount of refrigerant tanks to micro channel heat exchanger technology

ʯ One or two independent refrigerant circuits (2 or 4 scroll compressors) with single evaporator

ʯ Wide capacity range: 80 - 700 kW (“Single V” layout up to 210 kW, “Multi V” layout up to 700 kW)

ʯ Two efficiency level and 3 sound configurations Free cooling migration options available for Multi V models(1)

ʯ Partial and total heat recovery option available ʯ Stainless steel plate heat exchanger optimized for R-32 refrigerant operation

Air cooled chiller

Type of unit (rated power in accordance with EN14511) EWAT -B-XS 85 115 145 180 185 200Price € 23.295,- 26.692,- 30.694,- 40.018,- 34.507,- 43.548,-Commissioning by DAIKIN service (net price) € on request on request on request on request on request on requestCooling capacity kW 88 114 143 179 183 201Power input kW 28,8 36,6 44,4 57 63,6 65,7Refrigerant circuit 1 1 1 2 1 2Compressors 2 2 2 4 2 4EER 3,05 3,12 3,23 3,14 2,87 3,06SEER (+opt FANMOD)(1) 4,25 4,65 4,45 4,62 4,47 4,48Length x Width x Height mm 2.650x1.204x1.801 3.170x1.204x1.801 3.770x1.204x1.822 2.338x2.224x2.540 3.770x1.204x1.822 2.338x2.224x2.540Weight of unit / Operating weight kg 737/742 830/836 949/958 1.633/1.644 1.066/1.078 1.663/1.674Sound power / Sound pressure (at 1m) dB(A) 86/68 89/71 91/72 91/72 92/74 93/73Buffer tank volume / option (OP 134/135/136/137) liter 145 190 190 275 250 275

Optional accessories for chiller:Code Type of unit EWAT -B-XS 85 115 145 180 185 200Mechanical01 Total heat recovery € 3.129,- 3.417,- 4.344,- 5.305,- 5.305,- 6.191,-03A Partial heat recovery with control € 1.383,- 1.383,- 1.847,- 2.548,- 1.847,- 2.548,-08 Brine version € 285,- 285,- 285,- 285,- 285,- 285,-20 Evaporator victaulic kit € Standard21 Evaporator flange kit € 151,- 151,- 151,- 200,- 151,- 200,-29 20mm evaporator insulation € 285,- 285,- 285,- 285,- 285,- 285,-61 Discharge line shut-off valve €

n/a

601,-

n/a

601,-62 Suction line shut-off valve € 1.003,- 1.003,-63 High pressure side manometers € 276,- 276,-64 Low pressure side manometers € 276,- 276,-78 One centrifugal pump (low lift) € 2.456,- 2.610,- 2.715,- 3.998,- 2.715,- 4.065,-79 One centrifugal pump (high lift) € 2.979,- 2.979,- 3.167,- 4.124,- 3.167,- 4.124,-80 Two centrifugal pump (low lift) € 3.885,- 4.002,- 4.161,- 5.698,- 4.161,- 5.698,-81 Two centrifugal pump (high lift) € 4.650,- 4.650,- 4.775,- 6.083,- 4.775,- 6.083,-91 Double pressure relief valve with diverter € 961,- 961,- 961,- 1.428,- 961,- 1.428,-115 Water filter € 267,- 267,- 267,- 321,- 267,- 321,-121 Refrigerant leak detection € 1.048,- 1.048,- 1.048,-

n/a1.048,-

n/a126 Discharge and suction line shut-off valve € 802,- 802,- 802,- 802,-127 High and low pressure side manometers € 263,- 263,- 263,- 263,-134 One centrifugal pump (low lift) + tank € 4.135,- 4.299,- 4.395,- 5.857,- 4.395,- 5.924,-135 One centrifugal pump (high lift) + tank € 4.666,- 4.666,- 4.854,- 5.982,- 4.854,- 5.982,-136 Two centrifugal pump (low lift) + tank € 5.832,- 5.916,- 6.028,- 7.558,- 6.028,- 7.558,-137 Two centrifugal pump (high lift) + tank € 6.384,- 6.384,- 6.567,- 7.942,- 6.567,- 7.942,-139 E-coating microchannel coils € 1.203,- 1.605,- 2.005,- 3.158,- 2.005,- 3.158,-140 Unit guards (to cover unit access) € 501,- 543,- 586,- 1.454,- 586,- 1.454,-141 Side panels on coil ends €

n/a

401,-

n/a

401,-153 Blue coat € 586,- 586,-171 Free cooling migration - light € 11.280,- 11.280,-172 Free cooling migration - full € 23.396,- 23.396,-173 Free cooling migration - full with hydro kit € 25.901,- 25.901,-Electrical / Control04 Direct on line starter (dol) € Standard 06 Soft starter € 2.331,- 2.670,- 3.071,- 4.002,- 3.451,- 4.358,-10 Double setpoint € Standard 11 Compressor thermal overload relays € n/a 838,- n/a 838,-15 Under / over voltage control € 242,- 242,- 242,- 242,- 242,- 242,-16 Energy meter € on request on request on request 1.275,- on request 1.275,-17 Capacitors for power factor correction € n/a 1.003,- n/a 1.035,-17B Capacitors for power factor correction (single-v) € 501,- 534,- 565,- n/a 675,- n/a42 Speedtrol € n/a 1.621,- n/a 1.621,-57 Evaporator electric heater € Standard58 Evaporator flow switch € 301,- 301,- 301,- 375,- 301,- 375,-

Applied Systems Price list 2021-2022 41

Air cooled chiller

Optional accessories for chiller:

Code Type of unit EWAT -B-XS 85 115 145 180 185 20060 Electronic expansion valve €

Standard67 Ambient outside temperature sensor and setpoint reset €68 Hour run meter €69 General fault contactor €70 Alarm from external device €95 Compressors circuit breakers € 310,- 346,- 384,- 618,- 472,- 655,-96 Fans circuit breakers € 180,- 180,- 180,- 234,- 180,- 234,-97 Main switch interlock door € Standard99 Fans speed regulation (+ fan silent mode) € Standard n/a Standard n/a99a Fans speed regulation (vfd) €

n/a1.759,-

n/a1.759,-

102 Ground fault relay € 756,- 756,-120e Inverter kit for 1 centr pump low lift € 860,- 994,- 994,- 936,- 994,- 1.019,-120f Ínverter kit for 1 centr pump high lift € 994,- 994,- 994,- 1.073,- 994,- 1.073,-120g Inverter kit for 2 centr pump low lift €

n/a2.038,-

n/a2.038,-

120h Inverter kit for 2 centr pump high lift € 2.765,- 2.765,-128 Master/slave € Standard142A High ambient kit € 760,- 918,- 1.077,- n/a 1.077,- n/a143 Variable primary flow € Contact factory144 Diff pressure transd (shipped loose) € 1.457,- 1.457,- 1.457,- 1.457,- 1.457,- 1.457,-184 iCM standard € on request on request on request on request on request on request180 Modbus RTU MSTP € on request on request on request on request on request on request181 BACNet MSTP € on request on request on request on request on request on request182 BACNet IP € on request on request on request on request on request on request155 Daikin on site modem (with antenna) € 769,- 769,- 769,- 769,- 769,- 769,-160 100 pa esp fans € 510,- 669,- 827,- n/a 827,- n/a161 200 pa esp fans € n/a 10.227,- n/a 10.227,-Installation75 Rubber anti vibration mounts € 393,- 393,- 393,- 393,- 393,- 393,-77 Spring anti vibration mounts € 1.237,- 1.237,- 1.237,- 1.237,- 1.237,- 1.237,-83 External tank without cabinet (500 l) € 3.058,- 3.058,- 3.058,- 3.058,- 3.058,- 3.058,-84 External tank without cabinet (1000 l) € 4.081,- 4.081,- 4.081,- 4.081,- 4.081,- 4.081,-87 External tank with cabinet (500 l) € 4.499,- 4.499,- 4.499,- 4.499,- 4.499,- 4.499,-88 External tank with cabinet (1000 l) € 5.761,- 5.761,- 5.761,- 5.761,- 5.761,- 5.761,-Communication cards / AccessoriesEKCM200J BMS card (ModBUS-RTU) € 359,- 359,- 359,- 359,- 359,- 359,-EKCMBACMSTP BMS card (BacNet/ MSTP) € 431,- 431,- 431,- 431,- 431,- 431,-EKCMLON BMS card (LonWorks) € 420,- 420,- 420,- 420,- 420,- 420,-EKCMBACIP BMS card (BACnet/IP) € 582,- 582,- 582,- 582,- 582,- 582,-

(1) Option FANMOD consist in Continuous Fan Speed Regulation and improves part load operation, Single-V units are standardly equipped with continuous fan control, Modular-V units require opt 99a – VFD fans

42

EWAT-B-XLHigh efficiency rating, low noise level

ʯ R-32 refrigerant with low GWP. Reduced amount of refrigerant tanks to micro channel heat exchanger technology

ʯ One or two independent refrigerant circuits (2 or 4 scroll compressors) with single evaporator

ʯ Wide capacity range: 80 - 700 kW (“Single V” layout up to 210 kW, “Multi V” layout up to 700 kW)

ʯ Two efficiency level and 3 sound configurations Free cooling migration options available for Multi V models(1)

ʯ Partial and total heat recovery option available ʯ Stainless steel plate heat exchanger optimized for R-32 refrigerant operation

Air cooled chiller

Type of unit (rated power in accordance with EN14511) EWAT -B-XL 85 115 145 180 185 200Price € 23.762,- 27.226,- 31.307,- 42.620,- 35.201,- 46.381,-Commissioning by DAIKIN service (net price) € on request on request on request on request on request on requestCooling capacity kW 88 114 143 179 182 200Power input kW 28,8 36,6 44,4 57 63,6 65,7Refrigerant circuit 1 1 1 2 1 2Compressors 2 2 2 4 2 4EER 3,05 3,12 3,23 3,14 2,87 3,06SEER (+opt FANMOD)(1) 4,25 4,65 4,45 4,62 4,47 4,48Length x Width x Height mm 2.650x1.204x1.801 3.170x1.204x1.801 3.770x1.204x1.822 2.338x2.224x2.540 3.770x1.204x1.822 2.338x2.224x2.540Weight of unit / Operating weight kg 747/752 840/846 959/968 1.736/1.747 1.076/1.088 1.766/1.777Sound power / Sound pressure (at 1m) dB(A) 85/68 87/69 89/70 91/72 89/71 91/72Buffer tank volume / option (OP 134/135/136/137) liter 145 190 190 275 250 275

Optional accessories for chiller:Code Type of unit EWAT -B-XL 85 115 145 180 185 200Mechanical01 Total heat recovery € 3.129,- 3.417,- 4.344,- 5.305,- 5.305,- 6.191,-03A Partial heat recovery with control € 1.383,- 1.383,- 1.847,- 2.548,- 1.847,- 2.548,-08 Brine version € 285,- 285,- 285,- 285,- 285,- 285,-20 Evaporator victaulic kit € Standard21 Evaporator flange kit € 151,- 151,- 151,- 200,- 151,- 200,-29 20mm evaporator insulation € 285,- 285,- 285,- 285,- 285,- 285,-61 Discharge line shut-off valve €

n/a

601,-

n/a

601,-62 Suction line shut-off valve € 1.003,- 1.003,-63 High pressure side manometers € 276,- 276,-64 Low pressure side manometers € 276,- 276,-78 One centrifugal pump (low lift) € 2.456,- 2.610,- 2.715,- 3.998,- 2.715,- 4.065,-79 One centrifugal pump (high lift) € 2.979,- 2.979,- 3.167,- 4.124,- 3.167,- 4.124,-80 Two centrifugal pump (low lift) € 3.885,- 4.002,- 4.161,- 5.698,- 4.161,- 5.698,-81 Two centrifugal pump (high lift) € 4.650,- 4.650,- 4.775,- 6.083,- 4.775,- 6.083,-91 Double pressure relief valve with diverter € 961,- 961,- 961,- 1.428,- 961,- 1.428,-115 Water filter € 267,- 267,- 267,- 321,- 267,- 321,-121 Refrigerant leak detection € 1.048,- 1.048,- 1.048,- 1.048,- 1.048,- 1.048,-126 Discharge and suction line shut-off valve € 802,- 802,- 802,-

n/a802,-

n/a127 High and low pressure side manometers € 263,- 263,- 263,- 263,-134 One centrifugal pump (low lift) + tank € 4.135,- 4.299,- 4.395,- 5.857,- 4.395,- 5.924,-135 One centrifugal pump (high lift) + tank € 4.666,- 4.666,- 4.854,- 5.982,- 4.854,- 5.982,-136 Two centrifugal pump (low lift) + tank € 5.832,- 5.916,- 6.028,- 7.558,- 6.028,- 7.558,-137 Two centrifugal pump (high lift) + tank € 6.384,- 6.384,- 6.567,- 7.942,- 6.567,- 7.942,-139 E-coating microchannel coils € 1.203,- 1.605,- 2.005,- 3.158,- 2.005,- 3.158,-140 Unit guards (to cover unit access) € 501,- 543,- 586,- 1.454,- 586,- 1.454,-141 Side panels on coil ends €

n/a

401,-

n/a

401,-153 Blue coat € 586,- 586,-171 Free cooling migration - light € 11.280,- 11.280,-172 Free cooling migration - full € 23.396,- 23.396,-173 Free cooling migration - full with hydro kit € 25.901,- 25.901,-Electrical / Control04 Direct on line starter (dol) € Standard 06 Soft starter € 2.331,- 2.670,- 3.071,- 4.002,- 3.451,- 4.358,-10 Double setpoint € Standard 11 Compressor thermal overload relays € n/a 838,- n/a 838,-15 Under / over voltage control € 242,- 242,- 242,- 242,- 242,- 242,-16 Energy meter € on request on request on request 1.275,- on request 1.275,-17 Capacitors for power factor correction € n/a 1.003,- n/a 1.035,-17B Capacitors for power factor correction (single-v) € 501,- 534,- 565,- n/a 675,- n/a42 Speedtrol € n/a 1.621,- n/a 1.621,-57 Evaporator electric heater € Standard58 Evaporator flow switch € on request on request on request on request on request on request

Applied Systems Price list 2021-2022 43

Air cooled chiller

Optional accessories for chiller:

Code Type of unit EWAT -B-XL 85 115 145 180 185 20060 Electronic expansion valve €

Standard67 Ambient outside temperature sensor and setpoint reset €68 Hour run meter €69 General fault contactor €70 Alarm from external device €95 Compressors circuit breakers € 310,- 346,- 384,- 618,- 472,- 655,-96 Fans circuit breakers € 180,- 180,- 180,- 234,- 180,- 234,-97 Main switch interlock door € Standard99 Fans speed regulation (+ fan silent mode) € Standard n/a Standard n/a99a Fans speed regulation (vfd) €

n/a1.759,-

n/a1.759,-

102 Ground fault relay € 756,- 756,-120e Inverter kit for 1 centr pump low lift € 860,- 994,- 994,- 936,- 994,- 1.019,-120f Ínverter kit for 1 centr pump high lift € 994,- 994,- 994,- 1.073,- 994,- 1.073,-120g Inverter kit for 2 centr pump low lift €

n/a2.038,-

n/a2.038,-

120h Inverter kit for 2 centr pump high lift € 2.765,- 2.765,-128 Master/slave € Standard142A High ambient kit € 760,- 918,- 1.077,- n/a 1.077,- n/a143 Variable primary flow € Contact factory144 Diff pressure transd (shipped loose) € 1.457,- 1.457,- 1.457,- 1.457,- 1.457,- 1.457,-184 iCM standard € on request on request on request on request on request on request180 Modbus RTU MSTP € on request on request on request on request on request on request181 BACNet MSTP € on request on request on request on request on request on request182 BACNet IP € on request on request on request on request on request on request155 Daikin on site modem (with antenna) € 769,- 769,- 769,- 769,- 769,- 769,-160 100 pa esp fans € 510,- 669,- 827,- n/a 827,- n/a161 200 pa esp fans € n/a 10.227,- n/a 10.227,-Installation75 Rubber anti vibration mounts € 393,- 393,- 393,- 393,- 393,- 393,-77 Spring anti vibration mounts € 1.237,- 1.237,- 1.237,- 1.237,- 1.237,- 1.237,-83 External tank without cabinet (500 l) € 3.058,- 3.058,- 3.058,- 3.058,- 3.058,- 3.058,-84 External tank without cabinet (1000 l) € 4.081,- 4.081,- 4.081,- 4.081,- 4.081,- 4.081,-87 External tank with cabinet (500 l) € 4.499,- 4.499,- 4.499,- 4.499,- 4.499,- 4.499,-88 External tank with cabinet (1000 l) € 5.761,- 5.761,- 5.761,- 5.761,- 5.761,- 5.761,-Communication cards / AccessoriesEKCM200J BMS card (ModBUS-RTU) € 359,- 359,- 359,- 359,- 359,- 359,-EKCMBACMSTP BMS card (BacNet/ MSTP) € 431,- 431,- 431,- 431,- 431,- 431,-EKCMLON BMS card (LonWorks) € 420,- 420,- 420,- 420,- 420,- 420,-EKCMBACIP BMS card (BACnet/IP) € 582,- 582,- 582,- 582,- 582,- 582,-

(1) Option FANMOD consist in Continuous Fan Speed Regulation and improves part load operation, Single-V units are standardly equipped with continuous fan control, Modular-V units require opt 99a – VFD fans

44

EWAT-B-XRHigh efficiency rating, reduced noise level

ʯ R-32 refrigerant with low GWP. Reduced amount of refrigerant tanks to micro channel heat exchanger technology

ʯ One or two independent refrigerant circuits (2 or 4 scroll compressors) with single evaporator

ʯ Wide capacity range: 80 - 700 kW (“Single V” layout up to 210 kW, “Multi V” layout up to 700 kW)

ʯ Two efficiency level and 3 sound configurations Free cooling migration options available for Multi V models(1)

ʯ Partial and total heat recovery option available ʯ Stainless steel plate heat exchanger optimized for R-32 refrigerant operation

Air cooled chiller

Type of unit (rated power in accordance with EN14511) EWAT -B-XR 85 115 145 180 185 200Price € 24.477,- 28.045,- 32.247,- 44.470,- 36.259,- 48.239,-Commissioning by DAIKIN service (net price) € on request on request on request on request on request on requestCooling capacity kW 82 109 136 168 166 188Power input kW 30,8 38,9 46,9 59,1 70,5 69,8Refrigerant circuit 1 1 1 2 1 2Compressors 2 2 2 4 2 4EER 2,66 2,79 2,89 2,84 2,36 2,69SEER (+opt FANMOD)(1) 4,13 4,56 4,24 4,50 4,19 4,74Length x Width x Height mm 2.650x1.204x1.801 3.170x1.204x1.801 3.770x1.204x1.822 2.338x2.224x2.540 3.770x1.204x1.822 2.338x2.224x2.540Weight of unit / Operating weight kg 747/752 840/846 959/968 1.736/1.747 1.076/1.088 1.776/1.777Sound power / Sound pressure (at 1m) dB(A) 78/60 82/64 84/66 84/65 86/68 85/66Buffer tank volume / option (OP 134/135/136/137) liter 145 190 190 275 250 275

Optional accessories for chiller:Code Type of unit EWAT -B-XR 85 115 145 180 185 200Mechanical01 Total heat recovery € 3.129,- 3.417,- 4.344,- 5.305,- 5.305,- 6.191,-03A Partial heat recovery with control € 1.383,- 1.383,- 1.847,- 2.548,- 1.847,- 2.548,-08 Brine version € 285,- 285,- 285,- 285,- 285,- 285,-20 Evaporator victaulic kit € Standard21 Evaporator flange kit € 151,- 151,- 151,- 200,- 151,- 200,-29 20mm evaporator insulation € 285,- 285,- 285,- 285,- 285,- 285,-61 Discharge line shut-off valve €

n/a

601,-

n/a

601,-62 Suction line shut-off valve € 1.003,- 1.003,-63 High pressure side manometers € 276,- 276,-64 Low pressure side manometers € 276,- 276,-78 One centrifugal pump (low lift) € 2.456,- 2.610,- 2.715,- 3.998,- 2.715,- 4.065,-79 One centrifugal pump (high lift) € 2.979,- 2.979,- 3.167,- 4.124,- 3.167,- 4.124,-80 Two centrifugal pump (low lift) € 3.885,- 4.002,- 4.161,- 5.698,- 4.161,- 5.698,-81 Two centrifugal pump (high lift) € 4.650,- 4.650,- 4.775,- 6.083,- 4.775,- 6.083,-91 Double pressure relief valve with diverter € 961,- 961,- 961,- 1.428,- 961,- 1.428,-115 Water filter € 267,- 267,- 267,- 321,- 267,- 321,-121 Refrigerant leak detection € 1.048,- 1.048,- 1.048,- 1.048,- 1.048,- 1.048,-126 Discharge and suction line shut-off valve € 802,- 802,- 802,-

n/a802,-

n/a127 High and low pressure side manometers € 263,- 263,- 263,- 263,-134 One centrifugal pump (low lift) + tank € 4.135,- 4.299,- 4.395,- 5.857,- 4.395,- 5.924,-135 One centrifugal pump (high lift) + tank € 4.666,- 4.666,- 4.854,- 5.982,- 4.854,- 5.982,-136 Two centrifugal pump (low lift) + tank € 5.832,- 5.916,- 6.028,- 7.558,- 6.028,- 7.558,-137 Two centrifugal pump (high lift) + tank € 6.384,- 6.384,- 6.567,- 7.942,- 6.567,- 7.942,-139 E-coating microchannel coils € 1.203,- 1.605,- 2.005,- 3.158,- 2.005,- 3.158,-140 Unit guards (to cover unit access) € 501,- 543,- 586,- 1.454,- 586,- 1.454,-141 Side panels on coil ends €

n/a

401,-

n/a

401,-153 Blue coat € 586,- 586,-171 Free cooling migration - light € 11.280,- 11.280,-172 Free cooling migration - full € 23.396,- 23.396,-173 Free cooling migration - full with hydro kit € 25.901,- 25.901,-Electrical / Control04 Direct on line starter (dol) € Standard 06 Soft starter € 2.331,- 2.670,- 3.071,- 4.002,- 3.451,- 4.358,-10 Double setpoint € Standard 11 Compressor thermal overload relays € n/a 838,- n/a 838,-15 Under / over voltage control € 242,- 242,- 242,- 242,- 242,- 242,-16 Energy meter € on request on request on request 1.275,- on request 1.275,-17 Capacitors for power factor correction € n/a 1.003,- n/a 1.035,-17B Capacitors for power factor correction (single-v) € 501,- 534,- 565,- n/a 675,- n/a57 Evaporator electric heater € Standard 58 Evaporator flow switch € 301,- 301,- 301,- 375,- 301,- 375,-60 Electronic expansion valve € Standard

Applied Systems Price list 2021-2022 45

Air cooled chiller

Optional accessories for chiller:

Code Type of unit EWAT -B-XR 85 115 145 180 185 20067 Ambient outside temperature sensor and setpoint reset €

Standard68 Hour run meter €69 General fault contactor €70 Alarm from external device €95 Compressors circuit breakers € 310,- 346,- 384,- 618,- 472,- 655,-96 Fans circuit breakers € 180,- 180,- 180,- 234,- 180,- 234,-97 Main switch interlock door € Standard99 Fans speed regulation (+ fan silent mode) € Standard n/a Standard n/a99a Fans speed regulation (vfd) € n/a Standard n/a Standard102 Ground fault relay € n/a 756,- n/a 756,-120e Inverter kit for 1 centr pump low lift € 860,- 994,- 994,- 936,- 994,- 1.019,-120f Ínverter kit for 1 centr pump high lift € 994,- 994,- 994,- 1.073,- 994,- 1.073,-120g Inverter kit for 2 centr pump low lift €

n/a2.038,-

n/a2.038,-

120h Inverter kit for 2 centr pump high lift € 2.765,- 2.765,-128 Master/slave € Standard142A High ambient kit € 760,- 918,- 1.077,- n/a 1.077,- n/a143 Variable primary flow € Contact factory144 Diff pressure transd (shipped loose) € 1.457,- 1.457,- 1.457,- 1.457,- 1.457,- 1.457,-184 iCM standard € on request on request on request on request on request on request180 Modbus RTU MSTP € on request on request on request on request on request on request181 BACNet MSTP € on request on request on request on request on request on request182 BACNet IP € on request on request on request on request on request on request155 Daikin on site modem (with antenna) € 769,- 769,- 769,- 769,- 769,- 769,-Installation75 Rubber anti vibration mounts € 393,- 393,- 393,- 393,- 393,- 393,-77 Spring anti vibration mounts € 1.237,- 1.237,- 1.237,- 1.237,- 1.237,- 1.237,-83 External tank without cabinet (500 l) € 3.058,- 3.058,- 3.058,- 3.058,- 3.058,- 3.058,-84 External tank without cabinet (1000 l) € 4.081,- 4.081,- 4.081,- 4.081,- 4.081,- 4.081,-87 External tank with cabinet (500 l) € 4.499,- 4.499,- 4.499,- 4.499,- 4.499,- 4.499,-88 External tank with cabinet (1000 l) € 5.761,- 5.761,- 5.761,- 5.761,- 5.761,- 5.761,-Communication cards / AccessoriesEKCM200J BMS card (ModBUS-RTU) € 359,- 359,- 359,- 359,- 359,- 359,-EKCMBACMSTP BMS card (BacNet/ MSTP) € 431,- 431,- 431,- 431,- 431,- 431,-EKCMLON BMS card (LonWorks) € 420,- 420,- 420,- 420,- 420,- 420,-EKCMBACIP BMS card (BACnet/IP) € 582,- 582,- 582,- 582,- 582,- 582,-

(1) Option FANMOD consist in Continuous Fan Speed Regulation and improves part load operation, Single-V units are standardly equipped with continuous fan control, Modular-V units require opt 99a – VFD fans

46

EWWQ-KBW1N ʯ One of the most compact units on the market ʯ Low energy consumption ʯ Low operating sound level ʯ Low refrigerant volume ʯ Stainless steel plate heat exchanger ʯ Extension possible to 183 kW ʯ Easy installation and maintenance ʯ Remote cooling or heating selection ʯ Water/water heat pump, with water reversibility ʯ Standard integrated: main switch, water filter, flow switch, air purge, and pressure ports

Water cooled chiller

Unit size EWWQ014KBW1N EWWQ025KBW1N EWWQ033KBW1N EWWQ049KBW1N Price € 4.793,- 6.431,- 7.448,- 10.157,-Cooling capacity kW 13,27 23,96 30,46 47,22Heating capacity(2) kW 16,40 29,85 38,76 57,59EER 4,29 4,27 4,23 4,19SEER 2,28 3 3,33 3,26Heat rejection capacity kW 16,08 29,02 37,64 57,26Space heating

Average climate water outlet 35°C

ηs (Seasonal space heating efficiency)

% 171 177 186 180

SCOP 4,075 4,225 4,45 4,3Seasonal space heating eff. class A+++

Sound power level dB(A) 64 64 71 67

OptionsOPZH glycol application to -5 °C LWE € 239,- 239,- 239,- 239,-OPZL glycol application to -10 °C LWE € 239,- 239,- 239,- 239,-

KitEKLS1 low noise kit 5 HP € 307,- – – – EKLS2 low noise kit 8/10/12 HP € – 307,- 307,- 307,-EKAC10C(3) BMS address card € 174,- 174,- 174,- 174,-EKRUMCA remote user interface € 322,- 322,- 322,- 322,-

Unit size EWWQ064KBW1N EWWQ049KAW1M* EWWQ064KAW1M*Price € 11.687,- 8.108,- 9.934,-Cooling capacity(1) kW 61,05 47,22 61,05Heating capacity(2) kW 75,17 57,59 75,17EER 4,23 4,19 4,23SEER 3,48 3,26 3,48Heat rejection capacity kW 74,28 57,26 74,28Space heating

Average climate water outlet 35°C

General ηs (Seasonal space heating efficiency)

% 189 180 189

SCOP 4,525 4,3 4,525Seasonal space heating eff. class A+++

Sound power level dB(A) 74 67 64(*) Multi modular unit for two or three module application, controller is available in options

OptionsOPZH glycol application to -5 °C LWE € 239,- 239,- 239,-OPZL glycol application to -10 °C LWE € 239,- 239,- 239,-

KitEKLS2 low noise kit 8/10/12 HP (2 pcs.) € 307,- 307,- 307,-EKAC10C(3) BMS address card € 174,- 174,- 174,-EKRUMCA (3) remote user interface € 322,- 322,- 322,-

Notes:

(1) Cooling: Ta DB/WB 35°C - LWE 7°C ( DT = 5°C) data according EN 14511: 2011

(2) Heating: Ta DB/WB 7°C/6°C - LWC 45°C (Dt=5°C), data according EN 14511: 2011

(3) EKAC10C is needed for direct BMS connection via Modbus and to install EKRUMCA

Applied Systems Price list 2021-2022 47

EWWQ-KBW1M ʯ Designed for indoor installation ʯ Cooling and/or heating application possible ʯ Available in 11 standards sizes ʯ Capacity range from 98 to 192 kW ʯ Combining with FCU and AHU for air conditioning purpose ʯ Supplying chilled water for process cooling ʯ Easy installation and maintenance

Water cooled chiller

Capacity index 098 113 128

Basic model EWWQ049KAW1MEWWQ049KAW1M

EWWQ049KAW1MEWWQ064KAW1M

EWWQ064KAW1MEWWQ064KAW1M

Control box(3) ECB2MUCW ECB2MUCW ECB2MUCWPrice € 19.494,- 21.375,- 23.256,-Cooling capacity(1) kW 94,4 108,2 122,1Heating capacity(2) kW 115,2 132,8 150,3Sound power level dB(A) 56 60 62

OptionsOPZH glycol application to -5°C LWE € 480,- 480,- 480,-OPZL glycol application to -10°C LWE € 480,- 480,- 480,-

Capacity index 147 162 177 192

Basic modelEWWQ049KAW1M EWWQ049KAW1MEWWQ049KAW1M

EWWQ049KAW1M EWWQ049KAW1M EWWQ064KAW1M

EWWQ049KAW1M EWWQ064KAW1M EWWQ064KAW1M

EWWQ064KAW1M EWWQ064KAW1M EWWQ064KAW1M

Control box(3) ECB3MUCW ECB3MUCW ECB3MUCW ECB3MUCW Price € 27.845,- 29.726,- 31.607,- 33.488,-Cooling capacity kW 141,6 155,5 163,3 183,2Heating capacity(2) kW 172,8 190,3 207,9 225,5Sound power level dB(A) 57 61 62 63

OptionsOPZH glycol application to -5°C LWE € 721,- 721,- 721,- 721,-OPZL glycol application to -10°C LWE € 721,- 721,- 721,- 721,-

Notes:

(1) Cooling: Ta DB/WB 35°C - LWE 7°C ( DT = 5°C) data according EN 14511: 2011

(2) Heating: Ta DB/WB 7°C/6°C - LWC 45°C (Dt=5°C), data according EN 14511: 2011

(3) EKAC200J is the serial card RS485/Modbus needed for BMS connection of the modular hydrocube unit (EWWQ-KA).

48

Water cooled chiller

EWW(H)Q-G(L)-SS ʯ Compact Water/Water Chiller with Scroll compressors ʯ Refrigerant R-410A ʯ Evaporator as plate heat exchanger ʯ Condenser as plate heat exchanger ʯ Certified by Eurovent ʯ High efficiency rating – Eurovent rating Class A ʯ Electronic expansion valve ʯ Sequential control for Master/Slave function as standard feature ʯ Partial heat recovery optionally available ʯ Soundproof enclosure (Sound Proof System) optionally available ʯ Installed pump optionally available

Operating limits (cooling only): Condenser outlet temperature: +25°C to + 55°CEvaporator outlet temperature: -10°C to + 15°C

Standard equipment › Main switch › Direct start › Double setpoint value › Evaporator electric heater › Electronic expansion valve › Evaporator insulation 20 mm › Accumulative fault message

cond

ense

r lea

ving

wat

er te

mpe

ratu

re

(con

dens

er o

utle

t tem

pera

ture

) [o C

]

60 operating limits

55

50

45

40

35

30

25

20-11 -8 -5 -2 1 4 7 10 13 16

Evaporator leaving water temperature [oC]

Operation with glycol

Applied Systems Price list 2021-2022 49

EWWQ-G-SSOne refrigerant circuit, standard efficiency rating

ʯ Single refrigerant circuit (2 scroll compressors) with single evaporator

ʯ Compact design to allow easy indoor installation or retrofit operations

ʯ Conceived for stacked installation of two single circuit units to reduce the footprint

ʯ Allows sequencing control (up to 4 units) without any external device ʯ Stainless steel plate heat exchanger ʯ Pump (low 100 kPa and high 200 kPa lift) available for evaporator and condenser

Type of unit (rated power in accordance with EN14511) EWWQ-G-SS 090 100 120 130 150 170 190 210 240 300 360Price € 17.855,- 19.045,- 20.331,- 21.702,- 22.963,- 25.194,- 27.185,- 27.903,- 29.832,- 36.091,- 41.143,-Commissioning by DAIKIN service (net price) € 335,- 335,- 335,- 335,- 335,- 335,- 335,- 335,- 335,- 335,- 335,-Cooling capacity kW 93,7 106 119 136 150 172 194 221 246 314 370Power input kW 21,3 24,0 26,9 30,5 33,9 38,9 43,8 51,2 56,6 70,2 84,0Refrigerant circuit 1 1 1 1 1 1 1 1 1 1 1Compressors 2 2 2 2 2 2 2 2 2 2 2EER 4,40 4,40 4,42 4,46 4,43 4,42 4,43 4,35 4,39 4,48 4,41SEER 5,43 5,58 6,04 5,89 6,03 6,03 5,71 6,09 6,0 6,12 5,48Length x Width x Height mm 2.432 x 928 x 1.066 2.264 x 928 x 1.066 2.432 x 928 x 1.066 2.432 x 928 x 1.186Weight of unit / Operating weight kg 516/ 555 606/ 652 728/ 782 762/ 821 795/ 859 832/ 901 871/ 946 921/ 1.010 934/ 1.023 1.083/ 1.195 1.181/ 1.311Space heating

Average climate water outlet 35°C

ηs (Seasonal space heating efficiency) % 163 163 165 168 168 168 167 164 162 166 166

SCOP 4,28 4,28 4,33 4,40 4,39 4,40 4,38 4,29 4,25 4,34 4,34Sound power / Sound pressure (at 1m) dB(A) 80/ 64 83/ 67 85/ 69 87/ 70 88/ 72 88/ 72 88/ 72 90/ 74 92/ 76 93/ 76 93/ 77

Optional accessories for chiller:

Code Type of unit EWWQ-G-SS 090 100 120 130 150 170 190 210 240 300 360Mechanical130 Evaporator and condenser victaulic kit €

Standard 29 20Mm evaporator insulation €60 Electronic expansion valve €07a Heat pump version (with reversibility on water side) € 307,- 307,- 307,- 307,- 307,- 307,- 307,- 307,- 307,- 307,- 307,-133 Stacked installation € 1.659,- 1.659,- 1.659,- 1.659,- 1.659,- 1.659,- 1.659,- 1.659,- 1.659,- 1.659,- 1.659,-08 Brine version € 482,- 482,- 482,- 482,- 482,- 482,- 482,- 482,- 482,- 482,- 482,-03 Partial heat recovery € 1.135,- 1.135,- 1.135,- 1.153,- 1.159,- 1.354,- 1.395,- 1.483,- 1.755,- 1.857,- 1.978,-33 20Mm condenser insulation € 173,- 173,- 173,- 173,- 173,- 173,- 173,- 173,- 173,- 173,- 173,-126 Discharge and suction line shut-off valve € 802,- 802,- 802,- 802,- 802,- 802,- 802,- 802,- 802,- 802,- 802,-127 High and low pressure side manometers € 263,- 263,- 263,- 263,- 263,- 263,- 263,- 263,- 263,- 263,- 263,-76-c Sound proof system (compressors jacket) € 920,- 832,- 750,- 750,- 750,- 750,- 750,- Not available76-b Sound proof system (compressor) € 3.025,- 3.025,- 3.025,- 3.025,- 3.025,- 3.025,- 3.025,- 3.025,- 3.025,- 3.025,- 3.025,-91 Double pressure relief valve with diverter € 960,- 960,- 960,- 960,- 960,- 960,- 960,- 960,- 960,- 960,- 960,-115 Water filter € 503,- 503,- 503,- 503,- 503,- 503,- 503,- 503,- 503,- 503,- 791,-122 Evaporator single pump (low lift) € 1.172,- 1.172,- 1.247,- 1.247,- 1.247,- 2.069,- 2.069,- 2.069,- 2.069,- 2.069,- 1.921,-123 Evaporator single pump (high lift) € 1.347,- 1.347,- 1.434,- 1.434,- 1.434,- 2.379,- 2.379,- 2.379,- 2.379,- 2.379,- 2.207,-124 Condenser single pump (low lift) € 1.406,- 1.406,- 1.496,- 1.496,- 1.496,- 2.483,- 2.483,- 2.483,- 2.483,- 2.483,- 2.305,-125 Condenser single pump (high lift) € 1.618,- 1.618,- 1.720,- 1.720,- 1.720,- 2.856,- 2.856,- 2.856,- 2.856,- 2.856,- 2.649,-Electrical / Control04 Dol starter € Standard Not available132 Part winidng start € Not available Standard 10 Double setpoint €

Standard

Not available 68 Hour run meter €

Standard 69 General fault contactor €97 Main switch interlock door €128 Master/Slave €06 Soft starter € 2.727,- 2.483,- 2.243,- 2.405,- 2.565,- 2.752,- 2.943,- 3.129,- 3.206,- Not available

15a Control expansion pack including (under / over voltage control,setpoint reset, demand limit, alarm from external device, expansion card pol965) € 392,- 392,- 392,- 392,- 392,- 392,- 392,- 392,- 392,- 392,- 392,-

17 Capacitors for power factor correction € 731,- 731,- 731,- 731,- 731,- 731,- 1.294,- 1.294,- 1.294,- 1.808,- 1.808,-58 Evaporator flow switch € 226,- 226,- 226,- 226,- 226,- 226,- 226,- 226,- 226,- 226,- 226,-59 Condenser flow switch € 226,- 226,- 226,- 226,- 226,- 226,- 226,- 226,- 226,- 226,- 226,-95 Compressors circuit breakers € 307,- 317,- 333,- 333,- 333,- 375,- 420,- 436,- 452,- 1.540,- 2.629,-102 Ground fault relay € 758,- 758,- 758,- 758,- 758,- 758,- 758,- 758,- 758,- 758,- 758,-

155 Daikin on site (with antenna) €on

requeston

requeston

requeston

requeston

requeston

requeston

requeston

requeston

requeston

requeston

requestInstallation75 Rubber anti vibration mounts € 193,- 193,- 193,- 193,- 193,- 193,- 193,- 193,- 193,- 193,- 193,-Communication cards / AccessoriesEKCM200J BMS card (ModBUS-RTU) € 359,- 359,- 359,- 359,- 359,- 359,- 359,- 359,- 359,- 359,- 359,-EKCMBACMSTP BMS card (BacNet/ MSTP) € 431,- 431,- 431,- 431,- 431,- 431,- 431,- 431,- 431,- 431,- 431,-EKCMLON BMS card (LonWorks) € 420,- 420,- 420,- 420,- 420,- 420,- 420,- 420,- 420,- 420,- 420,-EKCMBACIP BMS card (BacNet/IP) € 582,- 582,- 582,- 582,- 582,- 582,- 582,- 582,- 582,- 582,- 582,-

Water cooled chiller

50

EWHQ-G-SS

One refrigerant circuit, standard efficiency rating With reversible refrigerant circuit

Type of unit (rated power in accordance with EN14511) EWHQ-G-SS 100 120 130 150 160 190 210 240 270 340 400Price € 20.371,- 21.732,- 23.202,- 24.761,- 26.202,- 28.748,- 29.305,- 31.839,- 34.044,- 41.184,- 46.949,-Commissioning by DAIKIN service personnel (net price) € 338,- 338,- 338,- 338,- 338,- 338,- 338,- 338,- 338,- 338,- 338,-Cooling capacity kW 87,3 100 111 127 141 160 181 208 232 291 352Power input kW 22,4 25,3 28,5 32,0 35,6 41,1 46,0 53,3 59,1 73,7 88,4Refrigerant circuit 1 1 1 1 1 1 1 1 1 1 1Compressors 2 2 2 2 2 2 2 2 2 2 2EER 3,90 3,95 3,91 3,96 3,95 3,90 3,94 3,90 3,92 3,95 3,98SEER 5,23 4,96 4,67 4,89 4,84 5,03 5,0 4,99 4,93 5,72 5,55Length mm 2.432 2.432 2.264 2.264 2.264 2.432 2.432 2.432 2.432 2.432 2.432Width mm 928 928 928 928 928 928 928 928 928 928 928Height mm 1.066 1.066 1.066 1.066 1.066 1.066 1.066 1.066 1.066 1.186 1.186Weight of unit / Operating weight kg 519/558 608/654 728/782 770/830 808/873 838/908 880/955 930/1.019 941/1.031 1.090/1.202 1.203/1.334Space heating

Average climate water outlet 35°C

ηs (Seasonal space heating efficiency)

% 155 155 158 162 161 161 161 167 166 158 159

SCOP 4,08 4,08 4,14 4,24 4,23 4,23 4,22 4,37 4,35 4,16 4,17Sound power / Sound pressure (at 1m) dB(A) 80/64 83/67 85/69 87/70 88/72 88/72 88/72 90/74 92/76 93/76 93/77

Water cooled heat pump

Optional accessories for chiller:

Code Type of unit EWHQ-G-SS 100 120 130 150 160 190 210 240 270 340 400Mechanical130 Evaporator and condenser victaulic kit €

Standard 29 20Mm evaporator insulation €33 20Mm condenser insulation €60 Electronic expansion valve €133 Stacked installation € 1.675,- 1.675,- 1.675,- 1.675,- 1.675,- 1.675,- 1.675,- 1.675,- 1.675,- 1.675,- 1.675,-08 Brine version € 487,- 487,- 487,- 487,- 487,- 487,- 487,- 487,- 487,- 487,- 487,-03 Partial heat recovery € 1.146,- 1.146,- 1.146,- 1.163,- 1.169,- 1.368,- 1.408,- 1.499,- 1.773,- 1.876,- 1.996,-129 Liquid line dìshut of valve € 265,- 265,- 265,- 265,- 265,- 310,- 310,- 310,- 310,- 353,- 353,-126 Discharge and suction line shut-off valve € 810,- 810,- 810,- 810,- 810,- 810,- 810,- 810,- 810,- 810,- 810,-127 High and low pressure side manometers € 265,- 265,- 265,- 265,- 265,- 265,- 265,- 265,- 265,- 265,- 265,-76-c Sound proof system (compressors jacket) € 929,- 839,- 757,- 757,- 757,- 757,- 757,- Not available76-b Sound proof system (compressor) € 3.055,- 3.055,- 3.055,- 3.055,- 3.055,- 3.055,- 3.055,- 3.055,- 3.055,- 3.055,- 3.055,-91 Double pressure relief valve with diverter € 969,- 969,- 969,- 969,- 969,- 969,- 969,- 969,- 969,- 969,- 969,-115 Water filter € 508,- 508,- 508,- 508,- 508,- 508,- 508,- 508,- 508,- 508,- 798,-122 Evaporator single pump (low lift) € 1.185,- 1.185,- 1.260,- 1.260,- 1.260,- 2.090,- 2.090,- 2.090,- 2.090,- 2.090,- 1.939,-123 Evaporator single pump (high lift) € 1.361,- 1.361,- 1.448,- 1.448,- 1.448,- 2.404,- 2.404,- 2.404,- 2.404,- 2.404,- 2.229,-124 Condenser single pump (low lift) € 1.185,- 1.185,- 1.260,- 1.260,- 1.260,- 2.090,- 2.090,- 2.090,- 2.090,- 2.090,- 1.939,-125 Condenser single pump (high lift) € 1.361,- 1.361,- 1.448,- 1.448,- 1.448,- 2.404,- 2.404,- 2.404,- 2.404,- 2.404,- 2.229,-Electrical / Control04 Dol starter € Standard Not available132 Part winidng start € Not available10 Double setpoint €

Standard 68 Hour run meter €69 General fault contactor €97 Main switch interlock door €128 Master/Slave €06 Soft starter € 2.753,- 2.509,- 2.265,- 2.428,- 2.589,- 2.780,- 2.972,- 3.160,- 3.238,- Not available

15aControl expansion pack including (under / over voltage control,setpoint reset, demand limit, alarm from external device, expansion card pol965) € 398,- 398,- 398,- 398,- 398,- 398,- 398,- 398,- 398,- 398,- 398,-

17 Capacitors for power factor correction € 737,- 737,- 737,- 737,- 737,- 737,- 1.306,- 1.306,- 1.306,- 1.826,- 1.826,-58 Evaporator flow switch € 228,- 228,- 228,- 228,- 228,- 228,- 228,- 228,- 228,- 228,- 228,-59 Condenser flow switch € 228,- 228,- 228,- 228,- 228,- 228,- 228,- 228,- 228,- 228,- 228,-95 Compressors circuit breakers € 310,- 320,- 336,- 336,- 336,- 379,- 424,- 440,- 457,- 1.555,- 2.655,-102 Ground fault relay € 766,- 766,- 766,- 766,- 766,- 766,- 766,- 766,- 766,- 766,- 766,-

155 Daikin on site (with antenna) €on

requeston

requeston

requeston

requeston

requeston

requeston

requeston

requeston

requeston

requeston

requestInstallation75 Rubber anti vibration mounts € 194,- 194,- 194,- 194,- 194,- 194,- 194,- 194,- 194,- 194,- 194,-Communication cards / AccessoriesEKCM200J BMS card (ModBUS-RTU) € 359,- 359,- 359,- 359,- 359,- 359,- 359,- 359,- 359,- 359,- 359,-EKCMBACMSTP BMS card (BacNet/ MSTP) € 431,- 431,- 431,- 431,- 431,- 431,- 431,- 431,- 431,- 431,- 431,-EKCMLON BMS card (LonWorks) € 420,- 420,- 420,- 420,- 420,- 420,- 420,- 420,- 420,- 420,- 420,-EKCMBACIP BMS card (BacNet/IP) € 582,- 582,- 582,- 582,- 582,- 582,- 582,- 582,- 582,- 582,- 582,-

ʯ Operating limits cooling: Condenser outlet temperature: +25°C to + 55°C Evaporator outlet temperature: -10°C to + 15°C ʯ Operating limits heating:

Condenser outlet temperature: +20°C to + 50°C Evaporator outlet temperature: -8°C to + 15°C

Applied Systems Price list 2021-2022 51

EWWQ-L-SS

Standard efficiency rating, two refrigerant circuits

Type of unit (rated power in accordance with EN14511) EWWQ-L-SS 180 205 230 260 290 330Price € 33.791,- 34.197,- 36.677,- 39.067,- 41.744,- 45.153,-Commissioning by DAIKIN service personnel (net price) € 486,- 486,- 486,- 486,- 486,- 486,-Cooling capacity kW 187 215 244 273 303 345Power input kW 41,7 47,3 53,1 60,2 67,1 77,1Refrigerant circuit 2 2 2 2 2 2Compressors 4 4 4 4 4 4EER 4,49 4,55 4,60 4,53 4,52 4,47SEER 5,49 5,77 6,02 5,96 6,12 6,03Length mm 2.801 2.801 2.801 2.801 2.801 2.801Width mm 928 928 928 928 928 928Height mm 1.970 1.970 1.970 1.970 1.970 1.970Weight of unit / Operating weight kg 877/957 1.062/1.156 1.285/1.401 1.347/1.469 1.439/1.575 1.498/1.641Space heating Average climate

water outlet 35°C

ηs (Seasonal space heating efficiency)

% 172 171 173 170 170 167

SCOP 4,49 4,48 4,52 4,44 4,45 4,38Sound power / Sound pressure (at 1m) dB(A) 83/65 86/68 88/70 90/72 91/74 91/74

Water cooled chiller

ʯ Operating limits cooling: Condenser outlet temperature: +25°C to + 55°C Evaporator outlet temperature: -10°C to + 15°C ʯ Operating limits heating:

Condenser outlet temperature: +20°C to + 50°C Evaporator outlet temperature: -8°C to + 15°C

Optional accessories for chiller:

Code Type of unit 180 205 230 260 290 330Mechanical130 Evaporator and condenser victaulic kit €

Standard 29 20Mm evaporator insulation €60 Electronic expansion valve €

07a Heat pump version with reversibility on water side (including pursuit mode) € 307,- 307,- 307,- 307,- 307,- 307,-

08 Brine version € 960,- 960,- 960,- 960,- 960,- 960,-03 Partial heat recovery € 2.326,- 2.326,- 2.326,- 2.326,- 2.326,- 2.790,-33 20Mm condenser insulation € 350,- 350,- 350,- 350,- 350,- 350,-126 Discharge and suction line shut-off valve € 1.607,- 1.607,- 1.607,- 1.607,- 1.607,- 1.607,-127 High and low pressure side manometers € 523,- 523,- 523,- 523,- 523,- 523,-76-c Sound proof system (compressors jacket) € 2.148,- 1.946,- 1.746,- 1.746,- 1.746,- 1.746,-76-b Sound proof system (compressor) € 6.048,- 6.048,- 6.048,- 6.048,- 6.048,- 6.048,-91 Double pressure relief valve with diverter € 1.437,- 1.437,- 1.437,- 1.437,- 1.437,- 1.437,-115 Water filter € 503,- 503,- 503,- 503,- 503,- 791,-122 Evaporator single pump (low lift) €

Contact Factory123 Evaporator single pump (high lift) €Electrical / Control04 Dol starter €

Standard

10 Double setpoint €68 Hour run meter €69 General fault contactor €97 Main switch interlock door €128 Master/Slave €132 Part winidng start € Not available06 Soft starter € 5.884,- 5.391,- 4.904,- 5.238,- 5.575,- 5.961,-

15aControl expansion pack including (under / over voltage control,setpoint reset, demand limit, alarm from external device, expansion card pol965)

€ 392,- 392,- 392,- 392,- 392,- 392,-

17 Capacitors for power factor correction € 1.343,- 1.343,- 1.343,- 1.343,- 1.343,- 1.343,-58 Evaporator flow switch € 226,- 226,- 226,- 226,- 226,- 226,-59 Condenser flow switch € 226,- 226,- 226,- 226,- 226,- 226,-95 Compressors circuit breakers € 606,- 633,- 658,- 658,- 658,- 745,-102 Ground fault relay € 758,- 758,- 758,- 758,- 758,- 758,-155 Daikin on site (with antenna) € on request on request on request on request on request on requestInstallation75 Rubber anti vibration mounts € 272,- 272,- 272,- 272,- 272,- 272,-Communication cards / AccessoriesEKCM200J BMS card (ModBUS-RTU) € 359,- 359,- 359,- 359,- 359,- 359,-EKCMBACMSTP BMS card (BacNet/ MSTP) € 431,- 431,- 431,- 431,- 431,- 431,-EKCMLON BMS card (LonWorks) € 420,- 420,- 420,- 420,- 420,- 420,-EKCMBACIP BMS card (BacNet/IP) € 582,- 582,- 582,- 582,- 582,- 582,-

52

EWLQ-KBW1N ʯ One of the most compact units on the market ʯ Daikin scroll compressor ʯ Electronic DDC controller ʯ Low operating sound level ʯ Low energy consumption ʯ Low refrigerant volume ʯ Easy installation and maintenance ʯ Stainless steel plate heat exchanger ʯ Standard integrated: main switch, pressure ports, flow switch, filter, shutoff valves and air purge

Condenserless chiller

Unit size EWLQ014KBW1N EWLQ025KBW1N EWLQ033KBW1N EWLQ049KBW1N EWLQ064KBW1NPrice € 4.243,- 5.696,- 6.594,- 8.988,- 10.652,-Cooling capacity(1) kW 12,07 21,91 28,01 43,46 56,78EER 3,43 3,44 3,41 3,43 3,52Sound power level dB(A) 64 64 71 67 74

OptionsOPZH glycol application to -5°C LWE € 258,- 258,- 258,- 258,- 258,-OPZL glycol application to -10°C LWE € 258,- 258,- 258,- 258,- 258,-

KitEKLS1 low noise kit 5 HP € 307,- – – – –EKLS2 low noise kit 8/10/12 HP € – 307,- 307,- 307,- 307,-EKAC10C(2) BMS address card € 174,- 174,- 174,- 174,- 174,-EKRUMCA(2) remote user interface € 322,- 322,- 322,- 322,- 322,-

Notes:

(1) Cooling: Ta DB/WB 35°C - LWE 7°C ( DT = 5°C) data according EN 14511: 2011

(2) EKAC10C is needed for direct BMS connection via Modbus and to install EKRUMCA

Applied Systems Price list 2021-2022 53

EWLQ-G-SSOne refrigerant circuit, standard efficiency rating

ʯ Single refrigerant circuit ( scroll compressors) with single evaporator

ʯ For chilled water production, to be combined with a remote condensing unit

ʯ Compact design to allow easy indoor installation or retrofit operations

ʯ Conceived for stacked installation of two single circuit units to reduce the footprint

ʯ High efficiency and reliable scroll compressor ʯ Stainless steel plate heat exchanger

Type of unit (rated power in accordance with EN14511) EWLQ-G-SS 090 100 120 130 150 170 190 210 240 300 360Price € 16.430,- 17.526,- 18.712,- 19.973,- 21.131,- 23.185,- 25.017,- 25.678,- 27.456,- 33.214,- 37.864,-Commissioning by DAIKIN service (net price) € 333,- 333,- 333,- 333,- 333,- 333,- 333,- 333,- 333,- 333,- 333,-Cooling capacity kW 86,5 98,4 110 125 139 160 181 206 231 290 346Power input kW 22,4 25,8 29,2 33,0 36,8 42,0 47,0 54,2 59,9 75,6 91,8Refrigerant circuit 1 1 1 1 1 1 1 1 1 1 1Compressors 2 2 2 2 2 2 2 2 2 2 2EER 3,86 3,81 3,78 3,79 3,79 3,80 3,86 3,80 3,85 3,84 3,77Length mm 2.743 2.743 2.743 2.743 2.743 2.743 2.743 2.743 2.743 2.743 2.743Width mm 928 928 928 928 928 928 928 928 928 928 928Height mm 1.066 1.066 1.066 1.066 1.066 1.066 1.066 1.066 1.066 1.186 1.186Weight of unit / Operating weight kg 494/525 578/615 686/729 714/760 742/791 773/826 807/863 838/901 852/916 967/1.044 1.046/1.134Sound power / Sound pressure (at 1m) dB(A) 80/64 83/67 85/69 87/70 88/72 88/72 88/72 90/74 92/76 93/76 93/77

Optional accessories for chiller:

Code Type of unit EWLQ-G-SS 090 100 120 130 150 170 190 210 240 300 360Mechanical20 Evaporator victaulic kit €

Standard 29 20mm evaporator insulation €60 Electronic expansion valve €133 Stacked installation € 1.650,- 1.650,- 1.650,- 1.650,- 1.650,- 1.650,- 1.650,- 1.650,- 1.650,- 1.650,- 1.650,-08 Brine version € 479,- 479,- 479,- 479,- 479,- 479,- 479,- 479,- 479,- 479,- 479,-03 Partial heat recovery € Not available126 Discharge and suction line shut-off valve € 798,- 798,- 798,- 798,- 798,- 798,- 798,- 798,- 798,- 798,- 798,-127 High and low pressure side manometers € 261,- 261,- 261,- 261,- 261,- 261,- 261,- 261,- 261,- 261,- 261,-76-c Sound proof system (compressors jacket) € 914,- 828,- 747,- 747,- 747,- 747,- 747,- Not available76-b Sound proof system (compressor) € 3.009,- 3.009,- 3.009,- 3.009,- 3.009,- 3.009,- 3.009,- 3.009,- 3.009,- 3.009,- 3.009,-91 Double pressure relief valve with diverter € 955,- 955,- 955,- 955,- 955,- 955,- 955,- 955,- 955,- 955,- 955,-115 Water filter € 501,- 501,- 501,- 501,- 501,- 501,- 501,- 501,- 501,- 501,- 787,-122 Evaporator single pump (low lift) € 1.166,- 1.166,- 1.241,- 1.241,- 1.241,- 2.058,- 2.058,- 2.058,- 2.058,- 2.058,- 1.911,-123 Evaporator single pump (high lift) € 1.340,- 1.340,- 1.427,- 1.427,- 1.427,- 2.368,- 2.368,- 2.368,- 2.368,- 2.368,- 2.197,-Electrical / Control04 Dol starter € Standard Not available132 Part winidng start € Not available Standard10 Double setpoint €

Standard68 Hour run meter €69 General fault contactor €97 Main switch interlock door €128 Master/Slave €06 Soft starter € 2.713,- 2.472,- 2.231,- 2.393,- 2.552,- 2.739,- 2.927,- 3.113,- 3.297,- Not available

15aControl expansion pack including (under / over voltage control,setpoint reset, demand limit, alarm from external device, expansion card pol965)

€ 391,- 391,- 391,- 391,- 391,- 391,- 391,- 391,- 391,- 391,- 391,-

17 Capacitors for power factor correction € 727,- 727,- 727,- 727,- 727,- 727,- 1.288,- 1.288,- 1.288,- 1.798,- 1.798,-58 Evaporator flow switch € 225,- 225,- 225,- 225,- 225,- 225,- 225,- 225,- 225,- 225,- 225,-95 Compressors circuit breakers € 305,- 316,- 331,- 331,- 331,- 373,- 418,- 434,- 450,- 1.532,- 2.616,-102 Ground fault relay € 755,- 755,- 755,- 755,- 755,- 755,- 755,- 755,- 755,- 755,- 755,-

155 Daikin on site (with antenna) €on

requeston

requeston

requeston

requeston

requeston

requeston

requeston

requeston

requeston

requeston

requestInstallation75 Rubber anti vibration mounts € 191,- 191,- 191,- 191,- 191,- 191,- 191,- 191,- 191,- 191,- 191,-Communication cards / AccessoriesEKCM200J BMS card (ModBUS-RTU) € 359,- 359,- 359,- 359,- 359,- 359,- 359,- 359,- 359,- 359,- 359,-EKCMBACMSTP BMS card (BacNet/ MSTP) € 431,- 431,- 431,- 431,- 431,- 431,- 431,- 431,- 431,- 431,- 431,-EKCMLON BMS card (LonWorks) € 420,- 420,- 420,- 420,- 420,- 420,- 420,- 420,- 420,- 420,- 420,-EKCMBACIP BMS card (BacNet/IP) € 582,- 582,- 582,- 582,- 582,- 582,- 582,- 582,- 582,- 582,- 582,-

Condenserless chiller

54

EWLQ-L-SS Standard efficiency rating, two refrigerant circuits

ʯ Dual refrigerant circuit (scroll compressors) with single evaporator ʯ For chilled water production, to be combined with a remote condensing unit

ʯ Compact design to allow easy indoor installation or retrofit operations

ʯ High efficiency and reliable scroll compressor ʯ Stainless steel plate heat exchanger

Type of unit (rated power in accordance with EN14511) EWLQ-L-SS 180 205 230 260 290 330Price € 30.408,- 30.772,- 33.005,- 35.154,- 37.562,- 40.630,-Commissioning by DAIKIN service (net price) € 483,- 483,- 483,- 483,- 483,- 483,-Cooling capacity kW 173 197 224 249 279 317Power input kW 44,3 51,1 57,9 65,6 73,2 83,8Refrigerant circuit 2 2 2 2 2 2Compressors 4 4 4 4 4 4EER 3,91 3,86 3,87 3,79 3,81 3,78Length mm 2.801 2.801 2.801 2.801 2.801 2.801Width mm 928 928 928 928 928 928Height mm 1.970 1.970 1.970 1.970 1.970 1.970Weight of unit / Operating weight kg 832/894 1.007/1.081 1.202/1.292 1.252/1.345 1.333/1.436 1.380/1.486Sound power / Sound pressure (at 1m) dB(A) 83/65 86/68 88/70 90/72 91/74 91/74

Condenserless chiller

Optional accessories for chiller:

Code Type of unit EWLQ-L-SS 180 205 230 260 290 330Mechanical20 Evaporator victaulic kit €

Standard 29 20mm evaporator insulation €60 Electronic expansion valve €08 Brine version € 955,- 955,- 955,- 955,- 955,- 955,-126 Discharge and suction line shut-off valve € 1.598,- 1.598,- 1.598,- 1.598,- 1.598,- 1.598,-127 High and low pressure side manometers € 520,- 520,- 520,- 520,- 520,- 520,-76-c Sound proof system (compressors jacket) € 2.136,- 1.936,- 1.737,- 1.737,- 1.737,- 1.737,-76-b Sound proof system (compressor) € 6.018,- 6.018,- 6.018,- 6.018,- 6.018,- 6.018,-91 Double pressure relief valve with diverter € 1.430,- 1.430,- 1.430,- 1.430,- 1.430,- 1.430,-115 Water filter € 501,- 501,- 501,- 501,- 501,- 787,-122 Evaporator single pump (low lift) €

Contact Factory123 Evaporator single pump (high lift) €Electrical / Control04 Dol starter €

Standard

10 Double setpoint €68 Hour run meter €69 General fault contactor €97 Main switch interlock door €128 Master/Slave €132 Part winidng start € Not available06 Soft starter € 5.853,- 5.363,- 4.878,- 5.210,- 5.548,- 5.931,-

15aControl expansion pack including (under / over voltage control,setpoint reset, demand limit, alarm from external device, expansion card POL965)

€ 391,- 391,- 391,- 391,- 391,- 391,-

17 Capacitors for power factor correction € 1.335,- 1.335,- 1.335,- 1.335,- 1.335,- 1.335,-58 Evaporator flow switch € 225,- 225,- 225,- 225,- 225,- 225,-95 Compressors circuit breakers € 603,- 629,- 654,- 654,- 654,- 742,-102 Ground fault relay € 755,- 755,- 755,- 755,- 755,- 755,-155 Daikin on site (with antenna) € on request on request on request on request on request on requestInstallation75 Rubber anti vibration mounts € 271,- 271,- 271,- 271,- 271,- 271,-Communication cards / AccessoriesEKCM200J BMS card (ModBUS-RTU) € 359,- 359,- 359,- 359,- 359,- 359,-EKCMBACMSTP BMS card (BacNet/ MSTP) € 431,- 431,- 431,- 431,- 431,- 431,-EKCMLON BMS card (LonWorks) € 420,- 420,- 420,- 420,- 420,- 420,-EKCMBACIP BMS card (BacNet/IP) € 582,- 582,- 582,- 582,- 582,- 582,-

Applied Systems Price list 2021-2022 55

Factory-engineered system control to manage a chiller plant roomThus optimising its performance and increasing its reliability by: › Optimal start-up, sequencing & staging of chillers › Matching chiller capacity to load demand

AvailabilityDetermines whether chillers are available or not, based on: › Inputs from the chiller unit controllers › Modbus communication status › Pump status

Sequencing Optimises the order in which available chillers are turned on and off depending on operating hours, energy efficiency, etc.

Staging Calculates energy-optimal stage-up/stage-down of the chiller by determining the increased capacity demand by capacity control, compensation of temperature and rotation. This function aims at providing the most energy-efficient combination of chillers on a continuous basis.

Stopping Last Chiller/RecyclingCaptures a rise in demand when the last chiller is staged down, by operating the pump dedicated to the next ON chiller at a minimum VFD frequency.

Min/Max Operating Chiller SettingEnsures that the number of operating chillers always stays within a certain range, regardless of changes in demand.

› Optimise performance › Increase reliability › Reduce energy costs › Reduce maintenance costs › Factory-engineered and tested › Remote control and monitoring. From one-time commissioning to real-time commissioning

iCM's main functionalities:

Why choose iCM?

Daikin is the best qualified partner to optimise the operation of a Daikin chiller

plant room.

Remote control and monitoring possibilities(valid for both Standard and Customised versions)

› Connectivity to Daikin’s remote monitoring and control system (www.daikinonsite.com) for remote monitoring and service providing Internet connection to the main controller

› Integration with general BAS/BMS offered through BACnet or Modbus Modules based on BACnet/IP or Modbus RTU/RS-485 protocols

› Built-in HMI, Remote HMI, Web HMI and daikinonsite.com are available for control and configuration

intelligent Chiller Manager - iCM

56

intelligent Chiller Manager - iCM

iCM for units equipped with MT3 controller is available in two versions:

Standard versionConfigurable controller with apre-set library of applications.The standard system is dividedinto three configurationsaccording to how many chillersand peripherals it can manage.

Customised versionFree-programmable controller for those applications not covered by the Standard version.

Standard Customised

(Free-programmable )(Configuration )

(Basic) (≤4 MT3 chillers)

(Customised )(Light/Full)(≤4/≤8 MT3 chillers

& peripherals)

intelligent Chiller ManageriCM Basic(1), for evaporator side managementup to 8 chiller manageable (without peripheral device) €

EKDICMPAB6.113,-

iCM Light (2), for evaporator side managementup to 8 chiller, up to 4 evaporator pumps, up to 4 evaporator shut-off valves, 1 bypass valve (evaporator side) manageable €

EKDICMPAL14.789,-

iCM Full(2), for evaporator side managementup to 8 chiller, up to 8 evaporator pumps, up to 8 evaporator shut-off valves, 1 bypass valve (evaporator side) manageable €

EKDICMPAF22.025,-

iCM Customisedbased on ad hoc specifications € on request

intelligent Chiller ManageriCM Light(3), for evaporator and condenser side management up to 8 chillers, up to 4 evaporator pumps and 4 condenser pumps, up to 4 evaporator and 4 condenser shut-off valves, 1 bypass valve (evaporator side), 1 bypass valve (condenser side) manageable

EKDICMPWL

on request

iCM Full(3), for evaporator and condenser side management up to 8 chillers, up to 8 evaporator pumps and 8 condenser pumps, up to 8 evaporator and 8 condenser shut-off valves, 1 bypass valve (evaporator side), 1 bypass valve (condenser side) manageable

EKDICMPWF

on request

iCM

PAB

iCM

PAL

iCM

PAF

iCM

PAB

iCM

PWL

iCM

PWF

Applied Systems Price list 2021-2022 57

intelligent Chiller Manager - iCM

intelligent Chiller ManagerICM Basic(4), for evaporator side management of Daikin and Non-Daikin Chiller(5) up to 8 chillers (up to 2 non-Daikin) manageable €

EKDICMPAB-IOon request

iCM Light(4), for evaporator side management of Daikin and Non-Daikin Chiller(5) up to 8 chillers (up to 2 non-Daikin), up to 4 evaporator pumps, up to 4 evaporator shut-off valves, 1 bypass valve (evaporator side) manageable €

EKDICMPAL-IOon request

intelligent Chiller ManagerICM Light(3), for Cooling tower/Dry Cooler management up to 4 Cooling tower/Dry Cooler, up to 4 fan, up to 4 sump valves, up to 4 spray valves manageable €

EKDICMCTLon request

ICM Full(3), for Cooling tower/Dry Cooler management up to 4 groups of Cooling tower/Dry Cooler, up to 8 fan, up to 8 sump valves, up to 8 spray valves manageable €

EKDICMCTFon request

Scope and type of equipment which can be controlled by iCM

Commissioning and Installation iCM(6)

iCM Basic Configuration and settings, fine tuning on site

€CE.S_ICM_AS_BASIC

on requestiCM Light Configuration and settings, wiring test, fine tuning on site

€CE.S_ICM_AS_LIGHT

on requestiCM Full Configuration and settings, wiring test, fine tuning on site

€CE.S_ICM_AS_FULL

on request

iCM Customised€

CE.S_ICM_AS_COMon request

(1)EKDICMPAB is available for the following chiller series: EWAT_B, EW_Q-G, EW_Q-L, EWLD~I-, EWWS/H/D~J-, EWLS/H/D~J- EWWH~VZ A , EWWD~VZ A, EWWH~DZ, EWWD~DZ,

DWSC & DWDC.

(2) EKDICMPAL/ EKDICMPAF are available for the following chiller series: EWAH~TZB & C, EWAD~TZB & C, EWAD~T-(C), EWAT_B, EWAD~CF, EW_Q-G, EW_Q-L, EWLD~I-, EWWS/H/

D~J-, EWLS/H/D~J- EWWH~VZ A , EWWD~VZ A, EWWH~DZ, EWWD~DZ, DWSC & DWDC.

(3)The EKDICMPWL/F and EKDICMCTL/F option are available for the following chiller series: EW_Q-G, EW_Q_-L, EWWH~VZ A, EWWD~VZ A, EWWH~DZ, EWWD~DZ, DWSC &

DWDC.

(4) The EKDICMPAB/L-IO option are available for the following chiller series: EWAH~TZB & C, EWAD~TZB & C, EWAD~T-(C), EWAT_B.

(5) The control of third part chillers it is based on the temperature of each chiller (and not on the cooling capacity).

(6) Note that the price are net installer prices.

For Daikin chiller not listed above and equipped with MT4, iCM is embedded already in the unit and Option 184 is needed to be ordered to be activated. Additional information

can be found in the dedicated pages of MT4.

SpecificationChiller (Dedicated/Manifolded) ≤8

Operating mode Cooling Evaporator pumps (CSD/VFD) & (Dedicated/Manifolded)

≤8

Shut-off valves (evaporator side) ≤8

Bypass valve (evaporator side)

Condenser pumps (CSD/VFD) & (Dedicated/Manifolded)

≤8

Shut-off valves (condenser side) ≤8

Bypass valve (condenser side)

Cooling tower/Dry cooler fans (CSD/VFD) ≤(8x3)

iCM

PAB-

IOiC

MPA

L-IO

NON Daikin Chiller

NON Daikin Chiller

iCM

CTL

iCM

CTF

58

Introducing the new control system

Microtech® 4 NEW

New MT 4 controllers Main Benefits

Micro-processor 204MHz Faster computation

Memory 64MB Flash and 64MB SDRAM

Increase memory for more functionalities

Boot Time 10 secondsIncrease responsiveness

when supply power switching

Inbuilt EEV drivers1 x current controlled bipolar

1 x voltage controlled bi/unipolar

2 x Electronic Expansion valves embedded controls

Temperature inputs (AI1-AI2-AI3)

NTC10k, NTC100k, NI1000, PT1000, Digital inputs

More temperature Probes input range

Width 180mm Compact design

Inbuilt HMINew LCD

New rubber buttons and push & roll button

Improved look and feel

Microtech® 4

Daikin on SiteKit modem + antenna

(1) Option 186 and DoS must be selected when ordering the unit.

PERFORMANCE MONITORING RAPID RESTART

The new Microtech® 4 (MT4) controller is faster and smarter. With the hardware improvements introduced by the new controller on all air/water cooled chillers, advanced logics and algorithms development at unit level are possible.

ʯ Building Management System integration: possible without any extra hardware because communication protocols like Modbus and BACNet are available directly from the controller and activated from Factory when ordered or through the after-sales channel;

ʯ Intelligent Chiller Manager (Option 184): embedded directly in the unit controller with no additional hardware required. It is possible to have optimal sequencing and staging of Chillers, Heat Pumps and Multipurpose units composing a Plant and also to manage mixed Plant configurations in both, Heating and Cooling modes;

ʯ Remote control and monitoring with DOS (Option 155): MT4 controllers are equipped with a built-in IP interface. Using this interface, the plant connects itself automatically to Daikin on Site with no need for programming or making settings.

ʯ Performance monitoring (Option 186): this sensor-less algorithm calculates the unit cooling capacity by using refrigerant pressure and temperature readings. Electrical power is calculated either from compressor VFD power and fan, or directly measured through optional energy meter. As a standard, no extra-hardware is required. With the Performance Monitoring Option (Option 186) and a DoS subscription, the energy analysis is completely available through DoS(1).

The new Daikin air/water-cooled liquid chillers are equipped with Microtech® 4. The existing models will get an upgrade from MT 3 to MT 4 and take advantage from the main benefits and improvements of the new control system.

Applied Systems Price list 2021-2022 59

Microtech® 4 - intelligent Chiller manager

For Daikin unit equipped with MT4, iCM Standard is embedded directly into the unit controller with no additional hardware required. In addition for those applications not covered by the Standard version, iCM customized library and advanced control algorithm development is also available.

iCM (MT 3) can manage only cooling operation, while iCM (MT 4) cooling, heating and a plant made of different units (mix of chillers with the same compressor technology, mix of heat pumps with the same compressor technology, chiller and heat pump, chiller and multipurpose)

The new iCM can be ordered as an option of the unit. For all those units composing a plant, Option 184 must be selected and a License(1) code is generated and installed to the unit's MT 4 controller in order to activate iCM directly from factory. In case iCM is requested at later stage, the License can be easily ordered also separately, providing the order number of units and the corresponding individual serial numbers.

What are the main differences between old iCM (MT 3) and new iCM (MT 4)?

How to order the new iCM for units equipped with MT 4?

Control strategies

Advanced control strategies can be chosen to optimise units life time and the energy efficiency of chillers plant: › by sequencing it is decided which unit must start or stop; › by staging the unit shares the load based on a threshold specified by the user.

(1) In case of multiple units on the same plant an individual License code must be set on each unit to let the advanced functions be unlocked.

Feature Old iCM (MT 3)

New iCM (MT 4)

Number of chillers UP TO 8 UP TO 8

Plants with All Chillers YES YES

Plants with all Heat Pumps YES YES

Plants with Multipurpose YES YESMix of Chillers (max 2 circuits) + Multipurpose NO YES

Mix of Chillers + Heat Pumps NO YES

Chillers with Heat Recovery NO YES

Chillers with free cooling NO YES

Units with modulable capacity control YES YES

Units with step capacity control YES YES

iCM Standard key benefits:

› Significant performance increase › Energy and maintenance costs reduction › Reliability and life time increase › Remote control and DoS monitoring capability › No additional hardware installation requirements

Control options

iCM is able to manage different control options: › when heat recovery option is activated, iCM will check the running units, the heat demand, the cool demand and act accordingly;

› free cooling option (soon available).

60

intelligent Chiller Manager new product line up

intelligent Pump Manager (iPM) for iCM

Microtech® 4 - intelligent Chiller manager

ICM as unit option 184: ʯ Up to 8 Daikin chillers ʯ Mixed systems (chiller+heat pumps or chiller+ multipurpose) ʯ Heating/cooling operating modes ʯ Heat recovery management ʯ Free cooling management ʯ Units with modulable capacity control ʯ Units with step capacity control

The iPM is an external controller and I/Os packed in an external Control Panel to ease the connection to pumps that can be not close to the Chiller controller. iPM is available in two versions: ʯ EKDIPM05 for the management and control of up to 5 primary pumps(1)

ʯ EKDIPM10 for the management and control of up to 10 primary pumps(1)

intelligent Chiller Manager with MT4iCM Basic, for evaporator side managementup to 8 chiller manageable €

Option 184on request

EKDIPM05 for the management and control of up to 5 primary pumps(1)

€EKDIPM05on request

EKDIPM10 for the management and control of up to 10 primary pumps(1)

€EKDIPM10on request

UNIT

OPT

ION

184

UNIT

OPT

ION

184

+ EK

DIPM

05

UNIT

OPT

ION

184

+ EK

DIP

M10

UNIT

OPT

ION

184

+ EK

DIP

M05

UN

IT O

PTIO

N 18

4 +

2xE

KDIP

M05

UN

IT O

PTIO

N 18

4 +

2xE

KDIP

M10

(1) Two are needed in case of water cooled to control evaporator and condenser pumps.

What is needed for replacing the old iCM with MT4

iCM old version iCM (Option 184)

iPM 5 (EKDIPM05)

iPM 10 (EKDIPM10)

EKDICMPALiCM Light for AirCooled

for each unit

EKDICMPAF iCM full forAirCooled

for each unit

EKDICMPWLiCM Light forWaterCooled

for each unit

evaporator

condenser

EKDICMPWF iCM Full forWaterCooled

for each unit

evaporator

condenser

Applied Systems Price list 2021-2022 61

Coming soon

› Top class efficiency: SEER up to 5,41 and SCOP up to 4,07

› Cooling Only and Heat Pump availability

› Extended capacity range: 16 – 90 kW

› Environmentally friendly with R-32 refrigerant

› Inverter scroll compressors for hot water production up to 60 ° C

› New series extremely flexible with a wide range of applications

› Condenser fan silent mode option

› Inverter pump kit option with both low and high lift available

› One or two independent refrigerant circuits with one or two inverter scroll compressors

› Full compatibility with Daikin on Site

› Master/Slave option available as standard, allowing to connect up to 4 units working as single system

› High temperature kit as option for operation up to + 52 ° C Outside temperature

EWA/YT-CZ

EWAT-CZ Air Cooled Chiller & EWYT-CZ Heat Pump at a glance

Operating limits - cooling only

Chilled Water Hot Water

Ambient Temperature Ambient Temperature

Brine Low

Cold Cold

-15°C 20°C 45°C

-20°C -20°C

Comfort Process

Average Average

MediumData Center High

Warm WarmHigh temp. kit

+25°C 60°C

+52°C 35°C+45°C

7°C

Operating limits - heat pump

62

FWE-DT/DF

FWE-DT/DF

Concealed flexi type unit withlow ESP

AC fan motor unit for horizontal orvertical concealed mounting

ʯ Low unit casing height of 200mm ʯ Sirocco Fan leading to low noise operation ʯ Open control ʯ Multiple factory mounted valve combinations ʯ Increased flexibility of capacity setting in the field ʯ The air filter can easily be removed for cleaning

FWECSAFWEC3A

Low ESP duct unit FWE-D 03 04 05 06 07 08 10 112 pipe unitsFWE**DATN5V3-L/R/S/T*, 2 pipe unit, standard, without valves

€ 282,- 287,- 291,- 355,- 384,- 394,- 402,- 404,-

FWE**DATV5V3-L/R/S/T*, 2 pipe unit, with 3-ways 230V on/off valve, factory mounted

€ 415,- 420,- 420,- 468,- 499,- 511,- 521,- 526,-

FWE**DATT5V3-L/R/S/T*, 2 pipe unit, with 2-ways 230V on/off valve, factory mounted

€ 384,- 389,- 389,- 438,- 468,- 481,- 491,- 495,-

Cooling capacity (at High Speed)(1) kW 1,95 2,07 2,59 3,14 3,44 3,94 5,24 5,6Heating capacity (at High Speed)(2) kW 1,99 2,37 2,87 3,98 4,34 4,61 5,95 6,32Airflow m³/h 407 385 488 677 725 725 1032 1116Sound power level dB(A) 45 44 50 50 50 50 57 594 pipe unitsFWE**DAFN5V3-L/R/S/T*, 4 pipe unit, standard, without valves

€ 319,- 343,- 343,- 416,- 452,- 460,- 472,- 474,-

FWE**DAFV5V3-L/R/S/T *, 4 pipe unit, with 3-ways 230V on/off valves, factory mounted

€ 552,- 584,- 587,- 643,- 681,- 693,- 703,- 709,-

FWE**DAFT5V3-L/R/S/T*, 4 pipe unit, with 2-ways 230V on/off valves, factory mounted

€ 493,- 526,- 528,- 584,- 622,- 636,- 645,- 650,-

Cooling capacity (at High Speed)(1) kW 1,95 2,07 2,59 3,14 3,44 3,94 5,24 5,6Heating capacity (at High Speed)(3) kW 2,11 2,61 2,94 3,84 4,57 4,57 5,83 6,18Airflow (High Speed) m³/h 407 385 488 677 725 725 1032 1116Sound power level (High Speed) dB(A) 45 44 50 50 50 50 57 59

Notes:(1) Cooling: 2/4 pipe: air 27°CDB, 19°CWB; entering water 7°C; leaving water 12°C(2) Heating: 2 pipe: air 20°CDB, entering water 50°C, water flow as per cooling mode(3) Heating: 4 pipe: air 20°CDB, entering water 50°C, leaving water 40°C * L - Left side water & Right side electric connectionR- Right side water & Left side electric connectionS- Left side water & Left side electric connectionT- Right side water & Right side electric connection

Accessories for FWE-D 03 04 05 06 07 08 10 11

2 pipes 3-ways (with 4 ports) proportional valve

E4V2PN04V3DA E4V2PN06V3DA E4V2PN10V3DA

€ 383,- 383,- 383,-

4 pipes 3-ways (with 4 ports) proportional valve

E4V4PN04V3DA E4V4PN06V3DA E4V4PN10V3DA

€ 761,- 761,- 761,-

Applied Systems Price list 2021-2022 63

FWE-D 03 04 05 06 07 08 10 11

2-ways on-off 230V valve 2-pipesE2V2VN01V3WA

€ 104,-

2-ways on-off 230V valve 4-pipesE2V4VN01V3WA

€ 193,-

3-ways on-off 230V valve 2-pipesE3V2VN02V3WA

€ 193,-

3-ways on-off 230V valve 4-pipesE3V4VN02V3WA

€ 258,-,-

Additional drain panESFD01D6

€ 18,-

Vertical installation kitESFH01D5

€ 35,-

Electronic Controller - standard version It can operate with 3 speeds of fan only, if it also manages 2 valves on 4-pipes unit ; on/off control valve; heating/cooling function; digital input for external release or window contact

FWEC1A

€ 115,-

Electronic Controller - advanced version 3 or 4 stages speed controller; on/off control valve; heating/cooling function; digital input for external release or window contact; master/slave function via RS485 (ModBus protocol)

FWEC2A

€ 165,-

Electronic Controller - advanced plus version 3 or 4 stages speed controller (or stepless for EC motor); on/off control valve; heating/cooling function; digital input for external release or window contact; master/slave function via RS485 (ModBus protocol); timer with weekly program and illuminated LCD

FWEC3A

€ 225,-Split type electronic controller FWECSAP+FWECSAC

FWECSAP power control board 3 digital inputs and 1 configurable digital output; 3 analogue outputs 0-10V; Bus communication via RS485 (ModBus protocol); master/slave function up to 256 devices

FWECSAP

€ 170,-FWECSAC control panel for remote or on board installation 3 or 4 stages speed controller; on/off or modulating control valve; heating/cooling function; digital input for external release or window contact; digital input for central heating/cooling changeover; master/slave function via RS485 (ModBus protocol); timer with weekly program and illuminated LCD

FWECSAC

€ 129,-

Wall mounting kit (spacing collar) for FWEC1A /2A and 3A

FWFCKA

€ 13,-

Temperature sensor kit for FWEC1A /2A and 3A; with 1.5 meters of cable

FWTSKA

€ 13,-

Relative humidity sensor kit for FWEC2A and FWEC3A; with 1.5 meters of cable

FWHSKA

€ 25,-

Master/Slave interface for connection of max. 4 devices to a remote control; max. 3.2 Amp. operating current per device connection

EPIMSA6

€ 164,-

FWE-D

Accessories

64

Low ESP duct unit FWE-C 02 03 04 06 07 08 10FWE**CT-, 2 pipe unit, standard, without valves

€ 265,- 300,- 325,- 424,- 457,- 535,- 643,-

FWE**CTV, 2 pipe unit, with 3-ways 230V on/off valve, factory mounted

€ 457,- 493,- 519,- 617,- 652,- 728,- 837,-

FWE**CTT, 2 pipe unit, with 2-ways 230V on/off valve, factory mounted

€ 372,- 411,- 435,- 535,- 567,- 643,- 752,-

Cooling capacity (Total at Super High Speed)(1) kW 2,17 3,22 4,34 6,06 6,83 7,84 9,96Heating capacity (2-pipe at Super High Speed)(2) kW 2,79 4,28 5,61 7,66 9,26 10,50 13,00Airflow m³/h 430 638 910 1.195 1.559 1.753 2.177Sound power level dB(A) 51 61 58 62 62 64 65FWE**CF-, 4 pipe unit, standard, without valves

€ 309,- 350,- 378,- 488,- 521,- 612,- 720,-

FWE**CFV, 4 pipe unit, with 3-ways 230V on/off valves, factory mounted

€ 646,- 687,- 718,- 827,- 858,- 949,- 1.057,-

FWE**CFT, 4 pipe unit, with 2-ways 230V on/off valves, factory mounted

€ 525,- 564,- 593,- 701,- 737,- 827,- 935,-

Cooling capacity (Total at Super High Speed)(1) kW 2,10 3,16 3,98 6,05 6,78 7,79 9,91Heating capacity (4-pipe at Super High Speed)(3) kW 2,30 3,53 4,56 6,17 7,60 8,52 10,40Airflow (High Speed) m³/h 416 626 835 1.193 1.548 1.742 2.166Sound power level (High Speed) dB(A) 51 61 58 62 62 64 65

Accessories for FWE-C 02 03 04 06 07 08 10

2 pipes 3-ways on/off 230V valve kit On / Off function, including piping unit

EK2MV3B10C5

€ 109,-

2 pipes 2-ways on/off 230V valve kit On / Off function, including piping unit

EK2MV2B10C5

€ 82,-

4 pipes 3-ways on/off 230V valve kit On / Off function, including piping unit

EK4MV3B10C5

€ 188,-

4 pipes 2-ways on/off 230V valve kit On / Off function, including piping unit

EK4MV2B10C5

€ 161,-

Notes:

(1) Cooling: 2/4 pipe: air 27°CDB, 19°CWB; entering water 7°C; leaving water 12°C

(2) Heating: 2 pipe: air 20°CDB, entering water 50°C, water flow as per cooling mode

(3) Heating: 4 pipe: air 20°CDB, entering water 50°C, leaving water 40°C

FWE-C AC fan motor unit for horizontal concealed mounting

ʯ 2-pipe and 4-pipe units in 7 sizes ʯ 4-speed fan motor ʯ External pressure max. 40 Pa ʯ System pressure max. 16 bar ʯ Water temperature from + 3°C to +70°C ʯ Air temperature from +10°C to +36°C ʯ Factory mounted valve (both left and right side) ʯ Condensate pump not included ʯ Water connections and electrical connections standard - left

Low ESP duct fan coil

Applied Systems Price list 2021-2022 65

Medium ESP duct unit FWB-B 02 03 04 05 06 07 08 09 10FWB**BTN, 2 pipe unit, standard, without valves

€ 511,- 543,- 575,- 697,- 720,- 787,- 951,- 1.004,- 1.070,-

FWB**BTV, 2 pipe unit, with 3-ways 230V on/off valve, factory mounted

€ 673,- 708,- 740,- 858,- 885,- 951,- 1.122,- 1.175,- 1.242,-

FWB**BTNE, 2 pipe unit, without valves and electric heater, factory mounted

€ 821,- 855,- 890,- 1.040,- 1.067,- 1.132,- 1.321,- 1.375,- 1.441,-

FWB**BTVE, 2 pipe unit, with 3-ways 230V on/off valve and electric heater, factory mounted

€ 985,- 1.018,- 1.052,- 1.204,- 1.230,- 1.298,- 1.492,- 1.546,- 1.613,-

Cooling capacity (Total at High Speed)(1) kW 2,32 2,82 3,13 4,47 4,74 5,69 5,70 6,48 7,65Heating capacity (2-pipe at High Speed)(2) kW 2,54 2,80 3,00 4,70 5,15 5,56 5,95 6,57 7,18Heating capacity (4-pipe at High Speed)(3) kW 3,97 3,97 3,97 6,97 6,97 6,97 16,44 16,44 16,44Electric heater power input kW 2,0 2,0 2,0 2,5 2,5 2,5 3,0 3,0 3,0Airflow (High Speed) m³/h 371 371 371 722 722 722 905 905 905Sound power level (High Speed) dB(A) 58 58 58 60 60 60 69 69 69

Accessories for FWB-B 02 03 04 05 06 07 08 09 10

Additional single row heat exchanger max. + 95 ° C water temperature

EAH04A6 EAH07A6 EAH10A6

€ 174,- 203,- 275,-

3-ways 230V on/off valve kit Actuator 230V included

E2MV107A6

€ 179,-

2-ways 230V on/off valve kit (cooling heat exchanger) Actuator 230V included

E2MV207A6 E2MV210A6

€ 101,- 101,-

3-ways 230V on/off valve kit (additional heat exchanger) Actuator 230V included

E2MV307A6 E2MV310A6

€ 179,- 179,-

2-ways 230V on/off valve kit (additional heat exchanger) Actuator 230V included

E2MV207A6 E2MV210A6

€ 101,- 101,-

Fan stop thermostat Nedeed with controller FWEC1A

YFSTA6

€ 19,-

Drain pumpCDRP1A

€ 225,-

Plenum box insulated with circular connections (supply side)

EPAA02A6 EPAA05A6 EPAA08A6

€ 127,- 162,- 234,-

Notes:

(1) Cooling: indoor temp. 27°CDB, 19°CWB; entering water temp. 7°C, water temperature rise 5K.

(2) Heating: indoor temp. 20°CDB, 15°CWB; entering water temp. 45°C, water temperature drop 5K.

(3) Heating: 4 pipe: air 20°CDB, entering water 70°C, leaving water 60°C

FWB-B AC fan motor unit for horizontal concealed mounting

ʯ Low sound power levels and electrical absorption thanks to plastic impeller and improved electric motor

ʯ 2-pipe devices in 9 sizes ʯ 7- speed fan motor ʯ 3, 4 or 6 stage row cooling coil ʯ External pressure max. 80 Pa ʯ System pressure max. 10 bar ʯ Water temperature from + 5 ° C to + 95 ° C ʯ Air temperature from + 5 ° C to + 43 ° C ʯ Factory mounted 3-way valve ʯ Additional heating coil or factory -installed electric heater available

ʯ Condensate pump not included

Medium ESP duct fan coil

FWB-B will be soon phased out and replaced by the new model FWB-C

66

FWE-C, FWB-B

FWE-C 02 03 04 - 06 07 08 - 10

FWB-B 02 03 04 05 06 07 08 09 10

Electronic Controller - standard version It can operate with 3 speeds of fan only, if it also manages 2 valves on 4-pipes unit ; on/off control valve; heating/cooling function; digital input for external release or window contact

FWEC1A

€ 115,-

Electronic Controller - advanced version 3 or 4 stages speed controller; on/off control valve; heating/cooling function; digital input for external release or window contact; master/slave function via RS485 (ModBus protocol)

FWEC2A

€ 165,-

Electronic Controller - advanced plus version 3 or 4 stages speed controller (or stepless for EC motor); on/off control valve; heating/cooling function; digital input for external release or window contact; master/slave function via RS485 (ModBus protocol); timer with weekly program and illuminated LCD

FWEC3A

€ 225,-Split type electronic controller FWECSAP+FWECSAC

FWECSAP power control board 3 digital inputs and 1 configurable digital output; 3 analogue outputs 0-10V; Bus communication via RS485 (ModBus protocol); master/slave function up to 256 devices

FWECSAP

€ 170,-FWECSAC control panel for remote or on board installation 3 or 4 stages speed controller; on/off or modulating control valve; heating/cooling function; digital input for external release or window contact; digital input for central heating/cooling changeover; master/slave function via RS485 (ModBus protocol); timer with weekly program and illuminated LCD

FWECSAC

€ 129,-

Wall mounting kit (spacing collar) for FWEC1A /2A and 3A

FWFCKA

€ 13,-

Temperature sensor kit for FWEC1A /2A and 3A; with 1.5 meters of cable

FWTSKA

€ 13,-

Relative humidity sensor kit for FWEC2A and FWEC3A; with 1.5 meters of cable

FWHSKA

€ 25,-

Master/Slave interface for connection of max. 4 devices to a remote control; max. 3.2 Amp. operating current per device connection

EPIMSA6

€ 164,-

Controller for FWE-C and FWB-B

Applied Systems Price list 2021-2022 67

Medium ESP duct unit with DC fan motor FWP-A 02 03 04 05 06 07FWP**ATN, 2 pipe unit, standard, without valves

€ 728,- 760,- 789,- 925,- 935,- 998,-

FWP**ATV, 2 pipe unit, with 3-ways 230V on/off valve, factory mounted

€ 890,- 923,- 951,- 1.089,- 1.099,- 1.163,-

FWP**ATNE, 2 pipe unit, without valves and electric heater, factory mounted

€ 1.040,- 1.072,- 1.102,- 1.270,- 1.282,- 1.344,-

FWP**ATVE, 2 pipe unit, with 3-ways 230V on/off valve and electric heater, factory mounted

€ 1.202,- 1.235,- 1.263,- 1.436,- 1.446,- 1.510,-

Cooling capacity (Total at High Speed)(1) kW 2,38 2,88 3,19 4,58 4,85 5,80Heating capacity (2-pipe at High Speed)(2) kW 2,54 2,80 3,00 4,71 5,15 5,56Heating capacity (4-pipe at High Speed)(3) kW 3,02 3,02 3,02 5,68 5,68 5,68Electric heater power input kW 2,0 2,0 2,0 2,5 2,5 2,5Airflow (High Speed) m³/h 371 371 371 722 722 722Sound power level (High Speed) dB(A) 58 58 58 60 60 60

Accessories for FWP-A 02 03 04 05 06 07

Additional single row heat exchanger max. + 95 ° C water temperature

EAH04A6 EAH07A6

€ 174,- 203,-

3-way valve add. h/e Actuator 230V included

E2MV307A6

€ 179,-

2-way valve add. h/e Actuator 230V included

E2MV207A6

€ 101,-

Drain pumpCDRP1A

€ 225,-

Plenum box (insulated with circular connections (supply side)

EPAA02A6 EPAA05A6

€ 127,- 162,-

Notes:

(1) Cooling: indoor temp. 27°CDB, 19°CWB; entering water temp. 7°C, water temperature rise 5K.

(2) Heating: indoor temp. 20°CDB, 15°CWB; entering water temp. 45°C, water temperature drop 5K.

(3) Heating: 4 pipe: air 20°CDB, entering water 70°C, leaving water 60°C

FWP-A BLDC fan motor unit for horizontal concealed mounting.Continuous air flow regulation and fan speed modulation.

ʯ Low sound level and up to 50% energy saving thanks to the BLDC motor technology

ʯ 2-pipe devices in 6 sizes ʯ 3-stage fan motor ʯ External pressure max. 80 Pa ʯ System pressure max. 10 bar ʯ Water temperature from + 5 ° C to + 95 ° C ʯ Air temperature from + 5 ° C to + 43 ° C ʯ Factory mounted 3-way valve

Medium ESP duct fan coil

ʯ Additional heating coil or electric heater available ʯ Condensate pump not included

FWP-A will be soon phased out and replaced by the new model FWP-C

68

2-pipe unit FWN**AT 04 05 06 07 08 10Price € 837,- 898,- 1.502,- 1.588,- 1.640,- 1.716,-Cooling capacity (Total at High Speed)(1) kW 3,91 4,76 6,17 6,81 7,83 8,75Heating capacity (2-pipe at High Speed)(2) kW 4,85 5,79 7,67 8,65 9,46 10,70

4-pipe unit FWN**AF 04 05 06 07 08 10Price € 943,- 1.030,- 1.626,- 1.707,- 1.792,- 1.892,-Cooling capacity (Total at High Speed)(1) kW 3,88 4,72 6,06 6,69 7,70 8,60Heating capacity (4-pipe at High Speed)(3) kW 4,48 4,45 6,53 6,44 9,13 9,07

Accessories for FWN-A 04 05 06 07 08 10Electric heater low capacity EDEH04A6 EDEHS06A6 EDEHS10A6Capacity kW 2,0 3,0 4,5Price € 338,- 584,- 584,-Electric heater high capacity EDEH04A6 EDEHB06A6 EDEHB10A6Capacity kW 2,0 6,0 9,0Price € 338,- 584,- 584,-

2-pipe 3-way valveActuator 230V included

ED2MV04A6 ED2MV10A6

€ 250,- 250,-

4-pipe 3-way valveActuator 230V included

ED4MV04A6 ED4MV10A6

€ 481,- 481,-

Vertical drainpan EDDPV10A6

€ 19,-

Horizontal drainpan EDDPH10A6

€ 19,-

Fresh air intake Servomotor 24V ~ Incl. Positioner 0 ... 100%

EDMFA04A6 EDMFA06A6 EDMFA10A6

€ 1.131,- 1.144,- 1.172,-

Drain pumpCDRP1A

€ 225,-

Master/Slave interface for connection of max. 4 devices to a remote control; max. 3.2 Amp. operating current per device connection

EPIMSA6

€ 164,-

Notes:

(1) Cooling: Inlet/outlet water temperature 7/12 °C; inlet air temperature 27°C DB 19°C WB

(2) Heating: 2 pipe: air 20°CDB, entering water 50°C, water flow as per cooling mode

(3) Heating: 4 pipe: Inlet/outlet water temperature 70/60 °C; inlet air temperature 20°C DB

FWN-A BLDC fan motor unit for horizontal or vertical mounting.Continuous air flow regulation and fan speed modulation

ʯ Up to 70% energy savings with brushless DC motor technology compared to traditional technology

ʯ Instant adjustment to temperature and relative humidity changes ʯ Low operating sound level ʯ Highly flexible solutions: multiple sizes, piping topologies and connection valves

ʯ Available static pressure up to 70 Pa

Medium ESP flexi type fan coil

Applied Systems Price list 2021-2022 69

FWP-A, FWN-A

FWP-A 02 03 04 05 06 07

FWN-A 04 05 06 07 08 010

Electronic Controller - advanced plus version 3 or 4 stages speed controller (or stepless for EC motor); on/off control valve; heating/cooling function; digital input for external release or window contact; master/slave function via RS485 (ModBus protocol); timer with weekly program and illuminated LCD

FWEC3A

€ 225,-Split type electronic controller FWECSAP+FWECSACFWECSAP power control board 3 digital inputs and 1 configurable digital output; 3 analogue outputs 0-10V; Bus communication via RS485 (ModBus protocol); master/slave function up to 256 devices

FWECSAP

€ 170,-FWECSAC control panel for remote or on board installation 3 or 4 stages speed controller; on/off or modulating control valve; heating/cooling function; digital input for external release or window contact; digital input for central heating/cooling changeover; master/slave function via RS485 (ModBus protocol); timer with weekly program and illuminated LCD

FWECSAC

€ 129,-

Wall mounting kit (spacing collar) for FWEC1A /2A and 3A

FWFCKA

€ 13,-

Temperature sensor kit for FWEC1A /2A and 3A; with 1.5 meters of cable

FWTSKA

€ 13,-

Relative humidity sensor kit for FWEC2A and FWEC3A; with 1.5 meters of cable

FWHSKA

€ 25,-

Controller for FWP-A and FWN-A

70

2-pipe unit FWD**AT 04 06 08 10 12 16 18Price € 612,- 805,- 943,- 1.050,- 1.303,- 1.671,- 1.838,-Cooling capacity (Total at High Speed) (1) kW 3,90 6,20 7,80 8,82 11,90 16,40 18,30Heating capacity (2-pipe at High Speed) (2) kW 4,05 7,71 9,43 10,79 14,45 19,81 21,92Airflow m³/h 800 1.250 1.600 1.600 2.200 3.000 3.000Sound power level dB(A) 66 69 72 72 74 78 78

4-pipe unit FWD**AF 04 06 08 10 12 16 18Price € 718,- 937,- 1.095,- 1.212,- 1.527,- 1.935,- 2.122,-Cooling capacity (Total at High Speed) (3) kW 3,90 6,20 7,80 8,82 11,90 16,40 18,30Heating capacity (4-pipe at High Speed) (4) kW 4,49 6,62 9,21 9,21 15,86 21,15 21,15Airflow m³/h 800 1.250 1.600 1.600 2.200 3.000 3.000Sound power level dB(A) 66 69 72 72 74 78 78

Accessories for FWD-A 04 06 08 10 12 16 18

Electric heater low capacity

EDEH04A6 EDEHS06A6 EDEHS10A6 EDEHS12A6 EDEHS18A6kW 2,0 3,0 4,5 4,5 9,0

€ 338,- 584,- 584,- 584,- 659,-

Electric heater high capacity

EDEH04A6 EDEHB06A6 EDEHB10A6 EDEHB12A6 EDEHB18A6kW 2,0 6,0 9,0 9,0 12,0

€ 338,- 584,- 584,- 584,- 659,-2-pipe 3-way valve Actuator 230V included

ED2MV04A6 ED2MV10A6 ED2MV12A6 ED2MV18A6€ 250,- 250,- 250,- 260,-

4-pipe 3-way valve Actuator 230V included

ED4MV04A6 ED4MV10A6 2 x ED2MV12A6 2 x ED2MV18A6€ 481,- 481,- 500,- 520,-

Vertical drainpanEDDPV10A6 EDDPV18A6

€ 19,- 25,-

Horizontal drainpanEDDPH10A6 EDDPH18A6

€ 19,- 25,-

Fan stop thermostat YFSTA6€ 19,-

Fresh air intake Servomotor 24V ~ Incl. Positioner 0 ... 100%

EDMFA04A6 EDMFA06A6 EDMFA10A6 EDMFA12A6 EDMFA18A6€ 1.131,- 1.144,- 1.172,- 1.231,- 1.262,-

Drain pump CDRP1A

€ 225,-

FWD-A AC fan motor unit for horizontal concealed mounting

ʯ 2 and 4-pipe devices in 7 sizes ʯ 3-stage fan motor ʯ External pressure max. 120 Pa ʯ System pressure max. 10 bar ʯ Water temperature from + 5 ° C to + 95 ° C ʯ Air temperature from + 5 ° C to + 43 ° C ʯ Factory mounted 2 or 3 way valve ʯ Condensate pump not included

High ESP flexi type fan coil

Notes:

(1) Cooling: 2 pipe: air 27ºCDB, 19ºCWB; entering water 7ºC; leaving water 12ºC at nominal air flow and ESP

(2) Heating: 2 pipe: air 20ºCDB; entering water 50ºC; water flow as in cooling mode at nominal air flow and ESP

(3) Rating conditions 4-pipe: air 27ºCDB - 19ºCWB - entering water 7ºC - leaving water 12ºC at nominal air flow and ESP

(4) Rating conditions 4-pipe:g: 4-pipe: air 20ºCDB - entering water 70ºC - leaving water 60ºC at nominal air flow and ESP

Applied Systems Price list 2021-2022 71

FWD-A

Controller for FWD AT/AF

Controller for FWD 04 06 08 10 12 16 18Electronic Controller - standard version It can operate with 3 speeds of fan only, if it also manages 2 valves on 4-pipes unit ; on/off control valve; heating/cooling function; digital input for external release or window contact

FWEC1AFWEC1A

EPIB6 requested

€ 115,- 115,-Electronic Controller - advanced version 3 or 4 stages speed controller; on/off control valve; heating/cooling function; digital input for external release or window contact; master/slave function via RS485 (ModBus protocol)

FWEC2AFWEC2A

EPIB6 requested

€ 165,- 165,-Electronic Controller - advanced plus version 3 or 4 stages speed controller (or stepless for EC motor); on/off control valve; heating/cooling function; digital input for external release or window contact; master/slave function via RS485 (ModBus protocol); timer with weekly program and illuminated LCD

FWEC3AFWEC3A

EPIB6 requested

€ 225,- 225,-Split type electronic controller FWECSAP+FWECSAC

FWECSAP power control board 3 digital inputs and 1 configurable digital output; 3 analogue outputs 0-10V; Bus communication via RS485 (ModBus protocol); master/slave function up to 256 devices

FWECSAP

€ 170,-FWECSAC control panel for remote or on board installation 3 or 4 stages speed controller; on/off or modulating control valve; heating/cooling function; digital input for external release or window contact; digital input for central heating/cooling changeover; master/slave function via RS485 (ModBus protocol); timer with weekly program and illuminated LCD

FWECSAC

129,-

Wall mounting kit (spacing collar) for FWEC 1A /2A and 3A

FWFCKA€ 13,-

Temperature sensor kit for FWEC*A; with 1.5 meters of cable

FWTSKA€ 13,-

Relative humidity sensor kit for FWEC2A and FWEC3A; with 1.5 meters of cable

FWHSKA€ 25,-

Master/Slave interface for connection of max. 4 devices to a remote control; max. 3.2 Amp. operating current per device connection

EPIMSA6

€ 164,-

Power interfacefor using electronic remote controller FWEC(1,2,3)A + new split controller FWECSA

–EPIB6

€ 166,-

Notes:

For FWD size 12, 16 or 18 EPIB6 needs to be used for each FWD unit to connect to FWEC*A controllers.

If FWD size 12, 16 or 18 are used in Master/Slave application by using EPIMSA6 still EPIB6 needs to be used for each FWD to connect to EPIMSA6.

72

FWT-G wall mounted unit 02 03 04 05 06FWT**GT, 2 pipe unit,without valves

€ 359,- 372,- 430,- 517,- 553,-

Cooling capacity (Total at High Speed)(1) kW 2,40 2,67 3,27 4,49 5,21Heating capacity (2-pipe at High Speed)(2) kW 2,71 2,96 3,71 5,07 6,23Airflow m³/h 442 476 629 866 1.053Sound power level dB(A) 45 48 55 55 59

Cassette fan coils, Wall mounted fan coil

FWT-G AC fan motor unit for wall mounting

ʯ High aesthetic cabinet design ʯ Optimum air distribution ʯ Easy to install ʯ Wireless remote control up to 9 m distance ʯ 3-speed fan motor ʯ Wide operating range ʯ Low operating sound level thanks to tangential fan ʯ Insulated with self-extinguishing class 1 heat insulation ʯ Removable washable air filter (self-extinguishing class 1)

Accessories FWT-G 02 03 04 05 06

Standard wired remote controlMERCA

€ 143,-Simplified wired remote control(heating only)

SRC-HPA€ 75,-

Wireless controlWRC-HPC

€ 29,-

2-way valve - On/Off Actuator 230V and piping unit included

EKMV2C09B (3)

€ 88,-

3-way valve - On/Off Actuator 230V and piping unit included

EKMV3C09B (3)

€ 98,-

Notes:

(1) Cooling: 2 pipe: air 27°CDB, 19°CWB; entering water 7°C; leaving water 12°C.

(2) Heating: 2 pipe: air 20°CDB; entering water 50°C; leaving water as per cooling GPM.

(3) Pipe reduction 3/4” - 1/2” is required

Applied Systems Price list 2021-2022 73

FWF-B cassette unit 02 03 04 05

FWF**BT, 2 pipe unit, incl. condensate pump, without valves

€ 716,- 762,- 805,- 848,-

Cooling capacity (Total at Super High Speed)(1) kW 2,00 3,20 4,20 5,20Heating capacity (2-pipe at Super High Speed)(2) kW 2,90 4,00 5,40 6,70Airflow m³/h 468 468 660 876Sound power level dB(A) 44 44 50 55FWF**BF, 4 pipe unit, incl. condensate pump, without valves

€ 778,- 832,- 868,- 904,-

Cooling capacity (Total at Super High Speed)(1) kW 2,00 2,70 3,50 4,50Heating capacity (4-pipe at Super High Speed)(3) kW 3,80 3,80 4,90 6,10Airflow m³/h 468 438 618 822Sound power level dB(A) 44 46 52 57

Notes: Decoration panel is mandatory, it is included with other accessories in table on page 74.(1) Cooling: air 27°CDB, 19°CWB; entering water 7°C; leaving water 12°C(2) Heating: 2 pipe: air 20°CDB; entering water 50°C(3) Heating: 4 pipe: air 20°CDB; entering water 70°C; leaving water 60°C

FWC-B cassette unit(4) 06 07 08 09FWC**BT, 2 pipe unit, incl. condensate pump, without valves

€ 1.022,- 1.091,- 1.154,- 1.212,-

Cooling capacity (Total at Super High Speed)(1) kW 5,80 6,80 7,70 8,70Heating capacity (2-pipe at Super High Speed)(2) kW 8,00 8,90 10,60 12,10Airflow m³/h 1.062 1.236 1.518 1.776Sound power level dB(A) 43 47 53 57FWC**BF, 4 pipe unit, incl. condensate pump, without valves

€ 1.279,- 1.368,- 1.431,- 1.490,-

Cooling capacity (Total at Super High Speed)(1) kW 5,80 6,60 7,60 8,70Heating capacity (4-pipe at Super High Speed)(3) kW 7,50 8,40 9,70 11,00Airflow m³/h 1.032 1.200 1.476 1.746Sound power level dB(A) 43 47 53 57

Notes:

(1) Cooling: air 27°CDB, 19°CWB; entering water 7°C; leaving water 12°C

(2) Heating: 2 pipe: air 20°CDB; entering water 50°C

(3) Heating: 4 pipe: air 20°CDB; entering water 70°C; leaving water 60°C

(4) Decoration panel is mandatory, it is included with other accessories in table on page 74.

FWF-B Fan coil

ʯ Compact casing (570mm in width and depth) enables unit to fit flush into ceilings and match standard architectural modules, without cutting ceiling tiles

ʯ Optional fresh air intake ʯ System pressure max. 10 bar ʯ Water temperature from + 5°C to + 50°C for 2-pipe devices ʯ Water temperature from + 5°C to + 70°C for 4-pipe devices ʯ Standard drain pump with 750mm lift increases flexibility and installation speed

ʯ Possibility to shut 1 or 2 flaps for easy installations in corners.

FWC-B Fan coil

ʯ 360° air discharge ensures uniform air flow and temperature distribution

ʯ Optional fresh air intake ʯ System pressure max. 10 bar ʯ Water temperature from + 5°C to + 50°C for 2-pipe devices ʯ Water temperature from + 5°C to + 70°C for 4-pipe devices ʯ Standard drain pump with 850mm lift ʯ Possibility to shut 1 or 2 flaps for easy installation in corners

Cassette fan coil

74

FWC-B, FWF-B Accessories

Accessories for FWC-B, FWF-B

Options FWC-B FWF-B

Decoration Panel Round Flow StandardBYCQ140C

-€ 293,-

Decoration Panel 4-way blow -BYFQ60B3

€ 293,-

Sealing member of air discharge outletKDBHQ55C140 KDBH44BA60

€ 123,- 147,-

Long-life filterKAFP551K160 KAFQ441BA60

€ 114,- on request

Panel spacer -KDBQ44B60

€ 540,-

Fresh air intake kitCE.KDDQ55C140 KDDQ44XA60

€ 509,- 180,-

Remote Control WiredBRC315D (1)

€ 127,-

Central remote control Up to 64 groups can be controlled with a maximum of 128 devices per group

DCS302C51 (2)

€ 1.921,-

Electrical box with earth terminal (3 blocks)

KJB311A

€ 99,-

Unified on/off control Up to 16 device groups can be controlled; operating indication given by LED

DCS301B51 (5)

€ 809,-

Electrical box with earth terminal (2 blocks)

KJB212A

€ 88,-

Schedule timer 2 programmable on/off times per day; power reserve 48 hours

DST301B51 (5)(8)

€ 1.009,-Wiring adapter for electrical appendices 1 Additional board for external control and monitoring; on/off; operating and fault message; setpoint specification via 0 ... 140 Ohm signal for entire F1 / F2 line.

KRP2A52 (4)(8)

€ 392,-Wiring adapter for electrical appendices 2Additional board for external control and monitoring; on/off; operating and fault message; setpoint specification via 0 ... 140 ohm Signal for a P1 / P2 line.

KRP4A53 (4)(8)

€ 199,-

Remote control Infrared H/PBRC7F532F (11) BRC7E530 (11)

€ 202,- 202,-

Remote control Infrared C/OBRC7F533F (11) BRC7E531 (11)

€ 202,- 202,-

Applied Systems Price list 2021-2022 75

FWC-B, FWF-B Accessories

Accessories for FWC-B, FWF-B

Options FWC-B FWF-B

Installation box for adapter PCBKRP1H98A (9) KRP1BB101 (9)

€ 57,- 76,-

Remote Sensor with 12 meters of cable

KRCS01-4 KRCS01-1

€ 95,- 95,-

Intelligent touch controller Up to 2 device groups can be controlled with a maximum of 64 devices per group

DCS601C51 (3)(7)

€ 2.132,-

Electrical installation boxKJB411A

€ 165,-

Optional PCB for MOD-bus connectionEKFCMBCB (4)(8)

€ 103,-

2-way valve - On/Off Actuator 230V and piping unit included

EKMV2C09B (4)(6)(10)

€ 88,-

3-way valve - On/Off Actuator 230V and piping unit included

EKMV3C09B (4)(6)(10)

€ 98,-

Valve control PCBEKRP1C11

€ 90,-

Remote “On/Off” and “forced off” kit -EKRORO (12)

€ 31,-Modbus Interface for monitoring and control Universal control adapter provides external control/monitoring via 0-10 kΩ resistor or 0-10VDC input signals or floating contacts; operating or defrost signal, fault message as well as an interface to the Modbus protocol is possible; connection to P1 / P2 terminals (max 16 indoor units); a BRC remote control can be additionally connected

RTD-10

€ 392,-Modbus Interface for monitoring and control Modbus Adapter provides a communication interface to the Modbus protocol P1/P2 (maximum 16 internal devices); all indoor units are controlled simultaneously, monitoring is done individually per unit; a BRC remote control can be additionally connected

RTD-NET

€ € 295,-

Modbus Interface DIII External control via the building management system; connection to maximum 64 devices

EKMBDXA

€ 2.980,-

Notes:

1. Optional, electrical installation box with earth terminal KJB212A is required, if controller wires need to be installed in the wall.2. Requires electrical installation box with earth terminal KJB311A.3. Requires electrical installation box KJB411A.4. Requires installation box KRP1H98A for FWC-B and KRP1BB101 for FWF-B.5. Requires electrical installation box with earth terminal KJB212A, if built in the wall.6. Requires valve control PCB EKRP1C11.7. I-touch:

• Not allowed to use the i-touch for an installation with both fan coils and VRV units. • Can not be used in combination with fan coil units, that use MOD bus communication. • No Airnet or telephone connection possible.

8. Only 1 of these 4 options can be installed on 1 indoor unit.9. FWC -B: Max. 1 KRP1H98A box can be mounted on the unit.

Max. 2 PCB’s can be mounted in 1 KRP1H98A box. FWF-B: Max. 2 KRP1BB101 boxes can be mounted on the unit. Max. 1 PCB can be mounted in 1 KRP1BB101 box.

10. FWC-B - 2-pipe unit: 1 x valve kit + 1 x installation box for PCB KRP1H98A + 1 x valve control PCB EKRP1C11 FWC-B - 4-pipe unit: 2 x valve kit + 1 x installation box for PCB KRP1H98A + 1 x valve control PCB EKRP1C11

FWF-B - 2-pipe unit: 1 x valve kit + 1 x installation box for PCB KRP1BB101 + 1 x valve control PCB EKRP1C11. FWF-B - 4-pipe unit: 2 x valve kit + 1 x installation box for PCB KRP1BB101 + 1 x valve control PCB EKRP1C11.11. It is possible to change the operation mode, but this will not have an impact on

the water temperature. (No feed back to water source) It is not possible to select the “auto air flow” setting. Dry operation can be selected with this remote control, but this function is not available on the FWC-B / FWF-B model.

12. This option is needed to create T1 T2 wire.

All options are supplied as kit.

76

Floor standing fan coil

FWV-D AC fan motor unit for vertical mounting

ʯ 2-pipe and 4-pipe devices in 10 sizes ʯ 3-stage fan motor ʯ System pressure max. 10 bar ʯ Water temperature from + 5°C to + 95°C ʯ Factory mounted 3 way valve ʯ Condensate pump not included ʯ Water connections standard - left ʯ Electrical connections standard - right ʯ Valve packages are insulated, no extra drain pan required

Low Wall unit FWV 01 15 02 25 03 35 04 06 08 10FWV**DTN, 2 pipe unit, standard, without valve

€ 342,- 354,- 375,- 404,- 413,- 452,- 474,- 514,- 680,- 774,-

FWV**DTV, 2 pipe unit, with 3-way on/off 230V valve, factory mounted

€ 577,- 593,- 612,- 639,- 652,- 690,- 718,- 757,- 946,- 1.038,-

FWV**DATD6V3---, 2 pipe unit, with simplified 3-way on/off 230V valve, factory mounted

€ 462,- 477,- 499,- 525,- 535,- 575,- 605,- 643,- 816,- 907,-

Cooling capacity (Total)(1) kW 1,54 1,74 1,96 2,42 2,93 3,51 4,33 4,77 6,71 8,02Heating capacity (2-pipe at High Speed)(2) kW 2,14 2,20 2,57 3,20 3,81 4,78 5,10 5,95 7,83 10,03Airflow m³/h 319 344 344 442 442 640 706 785 1.011 1.393Sound power level dB(A) 47 49 50 48 48 52 53 56 61 67FWV**DFN, 4 pipe unit,standard, without valves

€ 396,- 413,- 432,- 462,- 480,- 517,- 556,- 598,- 782,- 872,-

FWV**DFV, 4 pipe unit, with 3-way on/off 230V valves, factory mounted

€ 821,- 843,- 860,- 890,- 907,- 946,- 985,- 1.025,- 1.232,- 1.325,-

FWV**DAFD6V3---, 4 pipe unit, with simplified 3-way on/off 230V valves, factory mounted

€ 639,- 659,- 675,- 708,- 723,- 762,- 814,- 853,- 1.050,- 1.142,-

Cooling capacity (Total) (1) kW 1,46 1,69 1,79 2,38 2,87 3,46 4,26 4,67 6,64 7,88Heating capacity (4-pipe at High Speed)(3) kW 1,90 2,02 2,01 2,92 3,08 4,80 5,05 5,30 7,91 8,35Airflow m³/h 307 330 327 432 431 628 690 763 998 1.362Sound power level dB(A) 45 79 50 48 47 51 56 59 60 66

AccessoriesOptional accessories are on pages 79-82.

Factory mounted accessories

Factory mounted options 01 15 02 25 03 35 04 06 08 103-way on/off 24V valve € on request3-way proportional on/off valves € on request2-way on/off 230V valve € on request2-way on/off 24V valves € on request2-way proportional on/off valve € on request4-rows coil (for 2 pipe unit only) € on request6-speeds fan motor € - on request - on req.Electric heater (for 2 pipe unit only) € on request

Factory mounted options 01 15 02 25 03 35 04 06 08 10FWEC1A Standard version € on requestFWEC2A Advanced version € on requestFWEC3A Advanced Plus version € on requestFWECSAP Power control board € on request

Notes:

(1) Cooling: air 27°CDB, 19°CWB; entering water 7°C; leaving water 12°C

(2) Heating: 2 pipe: air 20°CDB; entering water 50°C; water flow rate as during cooling

(3) Heating: 4 pipe: air 20°CDB; entering water 70°C; leaving water 60°C

Accessories as kits are included on page 79.

Additional single row h/e (4-row coil) can not be used in combination with electric heater.

Independent power supply is necessary for 24 V valve. FWEC1/2/3A are not suitable to control 24 V valve.

Controller FWEC3A is necessary for proportional valve.

Cooling capacity is related to High Speed, standard unit.

Applied Systems Price list 2021-2022 77

Flexi type fan coil

FWL-D AC fan motor unit for horizontal or vertical mounting

ʯ 2-pipe and 4-pipe devices in 10 sizes ʯ 3-stage fan motor ʯ System pressure max. 10 bar ʯ Water temperature from + 5°C to + 95°C ʯ Factory mounted 3 way valve ʯ Condensate pump not included ʯ Water connections standard - left ʯ Electrical connections standard – right ʯ Valve packages are insulated, no extra drain pan required

Flexible unit FWL 01 15 02 25 03 35 04 06 08 10FWL**DTN, 2 pipe unit,standard, without valve

€ 357,- 375,- 400,- 416,- 442,- 477,- 503,- 540,- 728,- 823,-

FWL**DTV, 2 pipe unit, with 3-way on/off 230V valve, factory mounted

€ 589,- 610,- 630,- 649,- 675,- 713,- 745,- 782,- 988,- 1.084,-

FWL**DATD6V3---, 2 pipe unit, with simplified 3-way on/off 230V valve, factory mounted

€ 477,- 495,- 519,- 538,- 564,- 598,- 630,- 667,- 860,- 954,-

Cooling capacity (Total)(1) kW 1,54 1,74 1,96 2,42 2,93 3,51 4,33 4,77 6,71 8,02Heating capacity (2-pipe at High Speed)(2) kW 2,14 2,20 2,57 3,20 3,81 4,78 5,10 5,95 7,83 10,03Airflow m³/h 319 344 344 442 442 640 706 785 1.011 1.393Sound power level dB(A) 47 49 50 48 48 52 53 56 61 67FWL**DFN, 4 pipe unit,standard, without valves

€ 416,- 437,- 449,- 485,- 503,- 556,- 584,- 625,- 832,- 923,-

FWL**DFV, 4 pipe unit, with 3-way on/off 230V valves, factory mounted

€ 837,- 855,- 872,- 904,- 925,- 976,- 1.006,- 1.043,- 1.274,- 1.366,-

FWL**DAFD6V3---, 4 pipe unit, with simplified 3-way on/off 230V valves, factory mounted

€ 656,- 675,- 690,- 725,- 745,- 796,- 837,- 878,- 1.095,- 1.185,-

Cooling capacity (Total)(1) kW 1,46 1,69 1,79 2,38 2,87 3,46 4,26 4,67 6,64 7,88Heating capacity (4-pipe at High Speed)(3) kW 1,90 2,02 2,01 2,92 3,08 4,80 5,05 5,30 7,91 8,35Airflow m³/h 307 330 327 432 431 628 690 763 998 1.362Sound power level dB(A) 45 49 50 48 47 51 56 59 60 66

AccessoriesOptional accessories are on pages 79-82.

Factory mounted accessories

Factory mounted options 01 15 02 25 03 35 04 06 08 103-way on/off 24V valve € on request3-way proportional on/off valves € on request2-way on/off 230V valve € on request2-way on/off 24V valves € on request2-way proportional on/off valve € on request4-rows coil (for 2 pipe unit only) € on request6-speeds fan motor € - on request - on req.Electric heater (for 2 pipe unit only) € on request

Factory mounted options 01 15 02 25 03 35 04 06 08 10FWEC1A Standard version € on requestFWEC2A Advanced version € on requestFWEC3A Advanced Plus version € on requestFWECSAP Power control board € on request

Notes:

(1) Cooling: air 27°CDB, 19°CWB; entering water 7°C; leaving water 12°C

(2) Heating 2 pipe: air 20°C DB - entering water 50°C - water flow as in cooling mode

(3) Heating: 4 pipe: air 20°CDB; entering water 70°C; leaving water 60°C

Accessories as kits are included on page 79.

Additional single row h/e (4-row coil) can not be used in combination with electric heater.

Independent power supply is necessary for 24 V valve. FWEC1/2/3A are not suitable to control 24 V valve.

Controller FWEC3A is necessary for proportional valve.

Cooling capacity is related to High Speed, standard unit.

78

FWM-D AC fan motor unit for horizontal or vertical concealedmounting

ʯ 2-pipe and 4-pipe devices in 10 sizes ʯ 3-stage fan motor ʯ System pressure max. 10 bar ʯ Water temperature from + 5°C to + 95°C ʯ Condensate pump not included ʯ Water connections standard - left ʯ Electrical connections standard – right ʯ Valve packages are insulated, no extra drain pan required

Flexible concealed unit FWM 01 15 02 25 03 35 04 06 08 10FWM**DTN, 2 pipe unit, standard, without valve

€ 288,- 307,- 318,- 342,- 352,- 378,- 396,- 432,- 570,- 646,-

FWM**DTV, 2 pipe unit, with 3-way on/off 230V valve, factory mounted

€ 525,- 543,- 553,- 577,- 587,- 620,- 639,- 678,- 834,- 909,-

FWM**DATD6V3---, 2 pipe unit, with simplified 3-way on/off 230V valve, factory mounted

€ 411,- 430,- 440,- 462,- 474,- 501,- 525,- 562,- 706,- 782,-

Cooling capacity (Total)(1) kW 1,54 1,74 1,96 2,42 2,93 3,51 4,33 4,77 6,71 8,02Heating capacity (2-pipe at High Speed)(2) kW 2,14 2,20 2,57 3,20 3,81 4,78 5,10 5,95 7,83 10,03Airflow m³/h 319 344 344 442 442 640 706 785 1.011 1.393Sound power level dB(A) 47 49 50 48 48 52 53 56 61 67FWM**DFN, 4 pipe unit, standard, without valves

€ 345,- 359,- 370,- 406,- 418,- 452,- 480,- 514,- 671,- 750,-

FWM**DFV, 4 pipe unit, with 3-way on/off 230V valves, factory mounted

€ 774,- 789,- 799,- 834,- 846,- 880,- 907,- 941,- 1.122,- 1.202,-

FWM**DAFD6V3---, 4 pipe unit, with simplified 3-way on/off 230V valves, factory mounted

€ 587,- 605,- 617,- 652,- 661,- 697,- 737,- 768,- 937,- 1.018,-

Cooling capacity (Total) (1) kW 1,46 1,69 1,79 2,38 2,87 3,46 4,26 4,67 6,64 7,88Heating capacity (4-pipe at High Speed)(3) kW 1,90 2,02 2,01 2,92 3,08 4,80 5,05 5,30 7,91 8,35Airflow m³/h 307 330 327 432 431 628 690 763 998 1.362Sound power level dB(A) 45 49 50 48 47 51 56 59 60 66

AccessoriesOptional accessories are on pages 79-82.

Factory mounted accessories

Factory mounted options 01 15 02 25 03 35 04 06 08 103-way on/off 24V valve € on request3-way proportional on/off valves € on request2-way on/off 230V valve € on request2-way on/off 24V valves € on request2-way proportional on/off valve € on request4-rows coil (for 2 pipe unit only) € on request6-speeds fan motor € - on request - on req.Electric heater (for 2 pipe unit only) € on requestFWECSAP - power control board € on request

Notes:

(1) Cooling: air 27°CDB, 19ºCWB; entering water 7°C; leaving water 12°C

(2) Heating 2 pipe: air 20°C DB - entering water 50°C - water flow as in cooling mode

(3 Heating: 4 pipe: air 20°CDB; entering water 70°C; leaving water 60°C

Accessories as kits are included on page 79.

Additional single row h/e (4-row coil) can not be used in combination with electric heater.

Independent power supply is necessary for 24 V valve. FWEC1/2/3A are not suitable to control 24 V valve.

Controller FWEC3A is necessary for proportional valve.

Cooling capacity is related to High Speed, standard unit.

Concealed flexi type fan coil

Applied Systems Price list 2021-2022 79

Accessories for FWV - FWL - FWM

FWV – FWL – FWMAccessories

Accessories for FWV/FWL/FWM 01 15 02 25 03 35 04 06 08 10Additional heat exchanger

The one-row heat exchanger is made of copper pipes and aluminum fins. Supplied as kit: 1) heat exchanger 2) fixing plate 3) self-tapping screws

ESRH02A6 ESRH03A6 ESRH06A6 ESRH10A6

€ 73,- 88,- 96,- 127,-Electric Heater

Kit contains: 1/ EEH Electric heater tape 2/ E box = elec. wiring and operating relays 3/ Set of heat-resistant plastic grilles (std grills need to be replaced)

Unit Heater Power consumption

Operting current

kw AFW01+15 EEH01 1,0 4,5FW02+25 EEH02 1,5 6,8FW03+35 EEH03 1,6 7,3FW04+06 EEH06 2,0 9,1FW08+10 EEH10 3,0 13,6

EEH01A6 EEH02A6 EEH03A6 EEH06A6 EEH10A6

€ 295,- 295,- 312,- 333,- 343,-2-pipe 3-ways 230V on/off valve kit

Kit contains: 1/ 3way Valve Body SIZE 1÷35 valve = 1/2” (kvs=1,7) SIZE 4÷10 valve = 3/4” (kvs=2,8) 2/ Electrothermal actuator ON/OFF activation - power supply 230V - total opening time cca 4 minutes - NC (Normally Closed) 3/ Thermal insulation on pipes and valve 4/ 2pcs of lockshield valve

E2MV03A6 E2MV06A6 E2MV10A6

€ 235,- 235,- 250,-4-pipe 3-ways 230V on/off valve kit

Kit contains: 1/ 2 pcs of 3way Valve Body SIZE 1÷35 valve = 1/2” (kvs=1,7) SIZE 4÷10 valve = 3/4” (kvs=2,8) 2/ 2 pcs of Electrothermal actuator ON/OFF activation - power supply 230V - total opening time cca 4 minutes - NC (Normally Closed) 3/ Thermal insulation on pipes and valve 4/ 4pcs of lockshield valve

E4MV03A6 E4MV06A6 E4MV10A6

€ 427,- 427,- 449,- 2 pipe 2-ways230V on/offvalve kit oncooling heatexchanger

Kit contains: 1/ 2way Valve Body SIZE 1÷6 valve = 1/2” (kvs=1,7) SIZE 8÷10 valve = 3/4” (kvs=2,8) 2/ Electrothermal actuator ON/OFF activation - power supply 230V - total opening time cca 4 minutes - NC (Normally Closed) 3/ without thermal insulation 4/ NO lockshield /shut of valve in the kit

E2MV2B07A6 E2MV2B10A6

€ 101,- 101,-2 pipe 2-ways230V on/offvalve kit onadditionalheatexchanger

Kit contains: 1/ 2way Valve Body SIZE 1÷10 valve = 1/2” (kvs=1,7) 2/ Electrothermal actuator ON/OFF activation - power supply 230V - total opening time cca 4 minutes - NC (Normally Closed) 3/ without thermal insulation 4/ NO lockshield /shut of valve in the kit

E2MV2B07A6

€ 101,-2-pipe simplified 3-ways 230V on/off valve kit

Kit contains: 1/ 3way Valve Body SIZE 1÷35 valve = 1/2” (kvs=1,7) SIZE 4÷10 valve = 3/4” (kvs=2,8) 2/ Electrothermal actuator ON/OFF activation - power supply 230V - total opening time cca 4 minutes - NC (Normally Closed) 3/ without thermal insulation 4/ NO lockshield /shut of valve in the kit

E2MVD03A6 E2MVD06A6 E2MVD10A6

€ 138,- 141,- 143,-4-pipe simplified 3-ways 230V on/off valve kit

Kit contains: 1/ 2 pcs of 3way Valve Body SIZE 1÷35 valve = 1/2” (kvs=1,7) SIZE 4÷10 valve = 3/4” (kvs=2,8) 2/ 2 pcs of Electrothermal actuator ON/OFF activation - power supply 230V - total opening time cca 4 minutes - NC (Normally Closed) 3/ without thermal insulation 4/ NO lockshield /shut of valve in the kit

E4MVD03A6 E4MVD06A6 E4MVD10A6

€ 256,- 262,- 265,-2-pipe 3-ways 24V on/off valve kit

Kit contains: 1/ 3way Valve Body SIZE 1÷35 valve = 1/2” (kvs=1,7) SIZE 4÷10 valve = 3/4” (kvs=2,8) 2/ Electrothermal actuator ON/OFF activation - power supply 24V - total opening time cca 4 minutes - NC (Normally Closed) 3/ Thermal insulation on pipes and valve 4/ 2pcs of lockshield valve

E2M2V03A6 E2M2V06A6 E2M2V10A6

€ 235,- 235,- 250,-

80

Accessories for FWV - FWL - FWM

FWV – FWL – FWMAccessories

Accessories for FWV/FWL/FWM 01 15 02 25 03 35 04 06 08 104-pipe 3-ways 24V on/off valve kit

Kit contains: 1/ 2 pcs of 3way Valve Body SIZE 1÷35 valve = 1/2” (kvs=1,7) SIZE 4÷10 valve = 3/4” (kvs=2,8) 2/ 2 pcs of Electrothermal actuator ON/OFF activation - power supply 24V - total opening time cca 4 minutes - NC (Normally Closed) 3/ Thermal insulation on pipes and valve 4/ 4pcs of lockshield valve

E4M2V03A6 E4M2V06A6 E4M2V10A6

€ 427,- 427,- 449,-2-pipe 3-ways proportional valve kit

Kit contains: 1/ 3way Valve Body SIZE 1÷35 valve = 1/2” (kvs=1,7) SIZE 4÷10 valve = 3/4” (kvs=2,8) 2/ Electronic valve actuator Proportional activation - power supply 24V - total opening time cca 8 second - 0-10V control signal 3/ Thermal insulation on pipes and valve 4/ 2pcs of lockshield valve

E2MPV03A6 E2MPV06A6 E2MPV10A6

€ 377,- 368,- 379,-4-pipe 3-ways proportional valve kit

Kit contains: 1/ 2 pcs 3way Valve Body SIZE 1÷35 valve = 1/2” (kvs=1,7) SIZE 4÷10 valve = 3/4” (kvs=2,8) 2/ 2 pcs Electronic valve actuator Proportional activation - power supply 24V - total opening time cca 8 second - 0-10V control signal 3/ Thermal insulation on pipes and valve 4/ 4pcs of lockshield valve

E4MPV03A6 E4MPV06A6 E4MPV10A6

€ 689,- 695,- 700,-2 pipe 2-ways 24V on/off valve kit oncooling heatexchanger

Kit contains: 1/ 2way Valve Body SIZE 1÷6 valve = 1/2” (kvs=1,7) SIZE 8÷10 valve = 3/4” (kvs=2,8) 2/ Electrothermal actuator ON/OFF activation - power supply 24V - total opening time cca 4 minutes - NC (Normally Closed) 3/ without thermal insulation 4/ NO lockshield /shut of valve in the kit

E2M2V207A6 E2M2V210A6

€ 101,- 101,-2 pipe 2-ways 24V on/off valve kiton additionalheatexchanger

Kit contains: 1/ 2way Valve Body SIZE 1÷10 valve = 1/2” (kvs=1,7) 2/ Electrothermal actuator ON/OFF activation - power supply 24V - total opening time cca 4 minutes - NC (Normally Closed) 3/ without thermal insulation 4/ NO lockshield /shut of valve in the kit

E2M2V207A6

€ 101,-2 pipe 2-waysproportionalvalve kit oncooling heatexchanger

Kit contains: 1/ 2way Valve Body SIZE 1÷6 valve = 1/2” (kvs=1,7) SIZE 8÷10 valve = 3/4” (kvs=2,8) 2/ Electronic valve actuator Proportional activation - power supply 24V - total opening time cca 8 second - 0-10V control signal 3/ without thermal insulation 4/ NO lockshield /shut of valve in the kit

E2MPV207A6 E2MPV210A6

€ 262,- 262,-2 pipe 2-waysproportionalvalve kit onadditionalheatexchanger

Kit contains: 1/2way Valve Body SIZE 1÷10 valve = 1/2” (kvs=1,7) 2/ Electronic valve actuator Proportional activation - power supply 24V - total opening time cca 8 second - 0-10V control signal 3/ without thermal insulation 4/ NO lockshield /shut of valve in the kit

E2MPV207A6

€ 262,-Fan stop thermostat

To prevent ventilating cold air during the heating stage If the water temperature inside the heat exchanger is lower than 42°C. (The bracket to fix fan stop thermostat is included in the kit.) Only required in combination with electromechanical controller

YFSTA6

€ 19,-Air intake & discharge grille

S: Back suction grille fixed fins, made of anodised aluminium complete with filter and galvanised steel plate subframe and recyclable acrylic fibre air filter.D: Discharge grille with double row of anodised aluminium swinging fins, complete with galvanised steel plate subframe.

EAIDF02A6 EAIDF03A6 EAIDF06A6 EAIDF10A6

€ 203,- 245,- 317,- 377,-

Applied Systems Price list 2021-2022 81

Accessories for FWV/FWL/FWM 01 15 02 25 03 35 04 06 08 10Supporting feet

Kit contains:

ESFV ESFVG FWV FWM2 2

2 2 -

0 1 -

4,2 x 13 mm4 8

2,9 x 9,5 mm 4 4

ESFV06A6 ESFV10A6

€ 25,- 25,-Supporting feet & grille

ESFVG02A6 ESFVG03A6 ESFVG06A6 ESFVG10A6

€ 36,- 45,- 50,- 70,-Fresh air intake

To prevent the water from freezing inside the heat exchanger during winter. Close the outdoor air inlet louvre when the system is not operational or use an anti-freeze solution.

EFA02A6 EFA03A6 EFA06A6 EFA10A6

€ 88,- 96,- 106,- 118,-Rear panel It is supplied for installation of units, in case

rear side can be seen (example: installation at the back of glass windows). Unit, in case of rear panel installation, can not be fixed to wall. Kit consists of: 1. rear upper closing panel 2. rear lower closing panel 3. screws

ERPV02A6 ERPV03A6 ERPV06A6 ERPV10A6

€ 45,- 48,- 59,- 73,-Plenum box with circular connections (only for FWM-D)

Unit size Plenum box Ø [mm] x nSize 01-02 EPCC02A6 180 x 2Size 25-03 EPCC03A6 180 x 2Size 35-06 EPCC06A6 180 x 3Size 08-10 EPCC10A6 180 x 4

EPCC02A6 EPCC03A6 EPCC06A6 EPCC10A6

€ 103,- 116,- 146,- 201,-Vertical auxiliary drainpan

Install it to collect condensation. Used for vertical FCUs

EDPVB6

€ 8,-Horizontal auxiliary drainpan

Install it to collect condensation. Used for horizontal FCUs

EDPHB6

€ 8,-Controller electro-mechanical, Built in

For installation on board the unit is used for: Manually changing the operation fan speed of the unit; Automatically setting the room temperature by operating the motor-ventilator of the unit, both during cooling and heating. - 4 position rotary speed selector switch

(three speeds + stop)- Cooling/Heating operation selector - Manual set thermostat

ECFWMB6

€ 48,-Wired remote controller, Standard version

Onboard or wall mounted installation: - Management of AC 3-speeds fan motor

(on/off and automatic speed change)- Management of on/off valve - Management of electric heater - Cooling / heating mode swithcing based

on air / water temperature- Clean contact for remote activation (e.g.

window contact, remote on/off)

FWEC1A

€ 115,-Wired remote controller, Advanced version

All functionality of FWEC1A, but additionally: - Management of AC 4-speeds fan motor

(on/off and automatic speed change)- Air relative humidity control - Master & Slave System on serial RS485

(Modbus communication protocol)- Integration in BMS

FWEC2A

€ 165,-Wired remote controller, Advanced Plus version

All functionality of FWEC2A, but additionally: - Management of BLDC fan motor - Management of proportional valve - Weekly timer programmed operating

mode- Configurable digital outputs

FWEC3A

€ 225,-

Accessories for FWV - FWL - FWM

FWV – FWL – FWMAccessories

82

Accessories for FWV - FWL - FWM

FWV – FWL – FWMAccessories

Accessories for FWV/FWL/FWM 01 15 02 25 03 35 04 06 08 10Split typecontroller

Power control board

FWECSAP

€ 170,-Control panel for remote or on board installation (connected to the power control board) All functionality of FWEC3A, but additionally: - Master & Slave System on Conveyed

Waves (CW)

FWECSAC

€ 129,-On board mounting kit, for FWEC*A, remote airprobe incl.

To install FWEC1/2/3A thermostat on board. (left or right side) Use it only for FWV / FWZ or FWL / FWR

Side doors on left & right side

ControllersOptional

Low wall unit Flexi type

FWECKA

€ 19,-Wall mounting kit (spacing collar), for FWEC 1A /2A and 3A

Wall mounting kit (spacing collar), for FWEC 1A /2A and 3A

FWFCKA

€ 13,-Temperature sensor kit, for FWEC*A

FWTSK sensor should be connected to the FWEC*A remote control using the supplied cable as accessory and, in case of prolongations, a shielded cable only. The sensor cable (1,5 m) can be cut to measure if necessary. Sensor must be positioned on the heat exchanger OR at the valve inlet (with or without vlave installation)

FWTSKA

€ 13,-Relative humidity sensor kit , for FWEC2A and FWEC3A (tempereture sensor kit is required)

Bound together the air temperature remote probe, the installation of the humidity remote probe allows: - To display on the controller the

environment humidity - To select the Dehumidification function

The dehumidification function, available only in the cooling mode, uses the terminal to reduce the environmental humidity by approximately 10% compared to the humidity present at the moment of function selection.

FWHSKA

€ 25,-Master / Slave interface

The EPIMSA6 Master/slave interface is used for connecting up to 4 units in parallel to one controller FWEC(1,2,3)A. With the new split controller FWECSA to connect more unit you don’t need EPIMSA6 with a saving in the installation time/cost. The capacity of the EPIMSA6 contacts is max 4 x 3 A.

EPIMSA6

€ 164,-Drain pump For FWL only vertical installation

CDRP1A

€ 225,-

Applied Systems Price list 2021-2022 83

Floor standing fan coil

FWZ-AFan coil with DC fan motor

ʯ 2-pipe and 4-pipe devices in 10 sizes ʯ Low sound level and up to 70% energy saving thanks to the BLDC motor technology

ʯ System pressure max. 10 bar ʯ Water temperature from + 5°C to + 95°C ʯ Factory mounted 3 way valve ʯ Condensate pump not included ʯ Water connections standard - left ʯ Electrical connections standard – right

Low Wall unit with DC fan motor FWZ 02 03 06 08FWZ**ATN, 2 pipe unit, standard, without valve

€ 564,- 596,- 690,- 863,-

FWZ**ATV, 2 pipe unit, with 3-way on/off 230V valve, factory mounted

€ 796,- 829,- 930,- 1.122,-

FWZ**AATD6V3---, 2 pipe unit, with simplified 3-way on/off 230V valve, factory mounted

€ 683,- 718,- 819,- 995,-

Cooling capacity (Total)(1) kW 2,64 4,96 6,32 10,08Heating capacity (2-pipe at High Speed)(2) kW 3,47 6,40 7,51 11,18Airflow m³/h 560 900 1.200 1.660Sound power level dB(A) 62 70 64 71FWZ**AFN, 4 pipe unit, standard, without valves

€ 615,- 654,- 774,- 951,-

FWZ**AFV, 4 pipe unit, with 3-way on/off 230V valves, factory mounted

€ 1.036,- 1.072,- 1.194,- 1.393,-

FWZ**AAFD6V3---, 4 pipe unit, with simplified 3-way on/off 230V valves, factory mounted

€ 855,- 892,- 1.025,- 1.212,-

Cooling capacity (Total)(1) kW 2,43 4,96 6,32 10,08Heating capacity (4-pipe at High Speed)(3) kW 2,46 4,19 6,45 10,06Airflow m³/h 560 900 1.200 1.660Sound power level dB(A) 62 70 64 71

AccessoriesOptional accessories are on pages 86-88.

Factory mounted accessories

Factory mounted options 02 03 06 083-way on/off 24V valve € on request2-way on/off 230V valve € on request2-way on/off 24V valves € on request4-rows coil (for 2 pipe unit only) € on requestElectric heater (for 2 pipe unit only) € on request

Factory mounted options 02 03 06 08FWEC3A Advanced Plus version € on requestFWECSAP power control board € on request

Notes:

(1) Cooling: 2 pipe: air 27°CDB, 19°CWB; entering water 7°C; leaving water 12°C

(2) Heating: 2 pipe: air 20°CDB, entering water 50°C, water flow as per cooling mode

(3) Heating: 4 pipe: air 20°CDB; entering water 70°C; leaving water 60°C

Accessories as kits are included on page 86..

Additional single row h/e (4-row coil) can not be used in combination with electric heater.

Independent power supply is necessary for 24 V valve. FWEC3A are not suitable to control 24 V valve.

Controller FWEC3A is necessary to control DC fan motor.

Cooling capacity is related to High Speed, standard unit.

84

Flexi type fan coil

FWR-AFan coil with DC fan motor

ʯ 2-pipe and 4-pipe devices in 10 sizes ʯ Low sound level and up to 70% energy saving thanks to the BLDC motor technology

ʯ System pressure max. 10 bar ʯ Water temperature from + 5°C to + 95°C ʯ Factory mounted 3 way valve ʯ Condensate pump not included ʯ For wall or ceiling mounted installation: ideal solution for spaces with no false ceilings

ʯ Instant adjustment to temperature and relative humidity changes ʯ Water connections standard - left ʯ Electrical connections standard – right

FLEXI type unit with DC fan motor FWR 02 03 06 08FWR**ATN, 2 pipe unit, standard, without valve

€ 587,- 639,- 737,- 941,-

FWR**ATV, 2 pipe unit, with 3-way on/off 230V valve, factory mounted

€ 821,- 872,- 976,- 1.199,-

FWR**AATD6V3---, 2 pipe unit, with simplified 3-way on/off 230V valve, factory mounted

€ 711,- 757,- 863,- 1.072,-

Cooling capacity (Total)(1) kW 2,64 4,96 6,32 10,08Heating capacity (2-pipe at High Speed)(2) kW 3,47 6,40 7,51 11,18Airflow m³/h 560 900 1.200 1.660Sound power level dB(A) 62 70 64 71FWR**AFN, 4 pipe unit, standard, without valves

€ 646,- 693,- 816,- 1.038,-

FWR**AFV, 4 pipe unit, with 3-way on/off 230V valves, factory mounted

€ 1.065,- 1.114,- 1.237,- 1.480,-

FWR**AAFD6V3---, 4 pipe unit, with simplified 3-way on/off 230V valves, factory mounted

€ 885,- 935,- 1.067,- 1.301,-

Cooling capacity (Total)(1) kW 2,43 4,96 6,32 10,08Heating capacity (4-pipe at High Speed)(3) kW 2,46 4,19 6,45 10,06Airflow m³/h 560 900 1.200 1.660Sound power level dB(A) 62 70 64 71

AccessoriesOptional accessories are on pages 86-88.

Factory mounted accessories

Factory mounted options 02 03 06 083-way on/off 24V valve € on request2-way on/off 230V valve € on request2-way on/off 24V valves € on request4-rows coil (for 2 pipe unit only) € on requestElectric heater (for 2 pipe unit only) € on request

Factory mounted options 02 03 06 08FWEC3A Advanced Plus version € on requestFWECSAP power control board € on request

Notes:

(1) Cooling: 2 pipe: air 27°CDB, 19°CWB; entering water 7°C; leaving water 12°C

(2) Heating: 2 pipe: air 20°CDB, entering water 50°C, water flow as per cooling mode

(3) Heating: 4 pipe: air 20°CDB; entering water 70°C; leaving water 60°C

Accessories as kits are included on page 86.

Additional single row h/e (4-row coil) can not be used in combination with electric heater.

Independent power supply is necessary for 24 V valve. FWEC1/2/3A are not suitable to control 24 V valve.

Controller FWEC3A is necessary to control DC fan motor.

Cooling capacity is related to High Speed, standard unit.

Applied Systems Price list 2021-2022 85

FWS-AFan coil with DC fan motor

ʯ 2-pipe and 4-pipe devices in 10 sizes ʯ Low sound level and up to 70% energy saving thanks to the BLDC motor technology

ʯ System pressure max. 10 bar ʯ Water temperature from + 5°C to + 95°C ʯ Factory mounted 3 way valve ʯ Condensate pump not included ʯ Continuous air flow regulation and fan speed modulation ʯ Instant adjustment to temperature and relative humidity changes ʯ Water connections standard - left ʯ Electrical connections standard – right

Concealed flexi type fan coil

FLEXI type unit with DC fan motor FWS 02 03 06 08FWS**ATN, 2 pipe unit, standard, without valve

€ 506,- 540,- 620,- 774,-

FWS**ATV, 2 pipe unit, with 3-way on/off 230V valve, factory mounted

€ 740,- 770,- 860,- 1.033,-

FWS**AATD6V3---, 2 pipe unit, with simplified 3-way on/off 230V valve, factory mounted

€ 625,- 659,- 748,- 904,-

Cooling capacity (Total)(1) kW 2,64 4,96 6,32 10,08Heating capacity (2-pipe at High Speed)(2) kW 3,47 6,40 7,51 11,18Airflow m³/h 560 900 1.200 1.660Sound power level dB(A) 62 70 64 71FWS**AFN, 4 pipe unit,standard, without valves

€ 559,- 608,- 693,- 868,-

FWS**AFV, 4 pipe unit, with 3-way on/off 230V valves, factory mounted

€ 976,- 1.025,- 1.114,- 1.310,-

FWS**AAFD6V3---, 4 pipe unit, with simplified 3-way on/off 230V valves, factory mounted

€ 796,- 846,- 946,- 1.129,-

Cooling capacity (Total)(1) kW 2,43 4,96 6,32 10,08Heating capacity (4-pipe at High Speed)(3) kW 2,46 4,19 6,45 10,06Airflow m³/h 560 900 1.200 1.660Sound power level dB(A) 62 70 64 71

AccessoriesOptional accessories are on pages 86-88.

Factory mounted accessories

Factory mounted options 02 03 06 083-way on/off 24V valve € on request2-way on/off 230V valve € on request2-way on/off 24V valves € on request4-rows coil (for 2 pipe unit only) € on requestElectric heater (for 2 pipe unit only) € on request

Factory mounted options 02 03 06 08FWEC3A Advanced Plus version € on requestFWECSAP power control board € on request

Notes:

(1) Cooling: 2 pipe: air 27°CDB, 19°CWB; entering water 7°C; leaving water 12°C

(2) Heating: 2 pipe: air 20°CDB, entering water 50°C, water flow as per cooling mode

(3) Heating: 4 pipe: air 20°CDB; entering water 70°C; leaving water 60°C

Accessories as kits are included onpage 86.

Additional single row h/e (4-row coil) can not be used in combination with electric heater.

Independent power supply is necessary for 24 V valve. FWEC3A are not suitable to control 24 V valve.

Controller FWEC3A is necessary to control DC fan motor.

Cooling capacity is related to High Speed, standard unit.

86

Accessories for FWZ - FWR - FWS

FWZ - FWR - FWSAccessories

Accessories for FWZ/FWR/FWS 02 03 06 08

Additional heat exchanger

The one-row heat exchanger is made of copper pipes and aluminum fins. Supplied as kit: 1) heat exchanger 2) fixing plate 3) self-tapping screws

ESRH02A6 ESRH03A6 ESRH06A6 ESRH10A6

€ 73,- 88,- 96,- 127,-

Electric heater

Kit contains: 1/ EEH Electric heater tape 2/ E box = elec. wiring and operating relays 3/ Set of heat-resistant plastic grilles (std grills need to be replaced) Unit Heater Power

consumptionOperting current

kw AFW02 EEH02 1,5 6,8FW03 EEH03 1,6 7,3FW06 EEH06 2,0 9,1FW08 EEH10 3,0 13,6

EEH02A6 EEH03A6 EEH06A6 EEH10A6

€ 295,- 312,- 333,- 343,-

2-pipe 3-ways 230V on/off valve kit

Kit contains: 1/ 3way Valve Body SIZE 2÷6 valve = 1/2” (kvs=1,7) SIZE 8 valve = 3/4” (kvs=2,8) 2/ Electrothermal actuator ON/OFF activation - power supply 230V - total opening time cca 4 minutes - NC (Normally Closed) 3/ Thermal insulation on pipes and valve 4/ 2pcs of lockshield valve

E2MV03A6 E2MV10A6

€ 235,- 250,-

4-pipe 3-ways 230V on/off valve kit

Kit contains: 1/ 2 pcs of 3way Valve Body SIZE 2÷6 valve = 1/2” (kvs=1,7) SIZE 8 valve = 3/4” (kvs=2,8) 2/ 2 pcs of Electrothermal actuator ON/OFF activation - power supply 230V - total opening time cca 4 minutes - NC (Normally Closed) 3/ Thermal insulation on pipes and valve 4/ 4pcs of lockshield valve

E4MV03A6 E4MV10A6

€ 427,- 449,-

2 pipe 2-ways 230Von/off valve kitcooling h/e

Kit contains: 1/ 2way Valve Body SIZE 2÷6 valve = 1/2” (kvs=1,7) SIZE 8 valve = 3/4” (kvs=2,8) 2/ Electrothermal actuator ON/OFF activation - power supply 230V - total opening time cca 4 minutes - NC (Normally Closed) 3/ without thermal insulation 4/ NO lockshield /shut of valve in the kit

E2MV2B07A6 E2MV2B10A6

€ 101,- 101,-

2 pipe 2-ways 230Von/off valve kitadditional h/e

Kit contains: 1/ 2way Valve Body SIZE 2÷8 valve = 1/2” (kvs=1,7) 2/ Electrothermal actuator ON/OFF activation - power supply 230V - total opening time cca 4 minutes - NC (Normally Closed) 3/ without thermal insulation 4/ NO lockshield /shut of valve in the kit

E2MV2B07A6

€ 101,-

2-pipe simplified 3-ways 230V on/off valve kit

Kit contains: 1/ 3way Valve Body SIZE 2÷3 valve = 1/2” (kvs=1,7) SIZE 6÷8 valve = 3/4” (kvs=2,8) 2/ Electrothermal actuator ON/OFF activation - power supply 230V - total opening time cca 4 minutes - NC (Normally Closed) 3/ without thermal insulation 4/ NO lockshield /shut of valve in the kit

E2MVD03A6 E2MVD06A6 E2MVD10A6

€ 138,- 141,- 143,-

4-pipe simplified 3-ways 230V on/off valve kit

Kit contains: 1/ 2 pcs of 3way Valve Body SIZE 2÷3 valve = 1/2” (kvs=1,7) SIZE 6÷8 valve = 3/4” (kvs=2,8) 2/ 2 pcs of Electrothermal actuator ON/OFF activation - power supply 230V - total opening time cca 4 minutes - NC (Normally Closed) 3/ without thermal insulation 4/ NO lockshield /shut of valve in the kit

E4MVD03A6 E4MVD06A6 E4MVD10A6

€ 256,- 262,- 265,-

2-pipe 3-ways 24V on/off valve kit

Kit contains: 1/ 3way Valve Body SIZE 2÷3 valve = 1/2” (kvs=1,7) SIZE 6÷8 valve = 3/4” (kvs=2,8) 2/ Electrothermal actuator ON/OFF activation - power supply 24V - total opening time cca 4 minutes - NC (Normally Closed) 3/ Thermal insulation on pipes and valve 4/ 2pcs of lockshield valve

E2M2V03A6 E2M2V06A6 E2M2V10A6

€ 235,- 235,- 250,-

Applied Systems Price list 2021-2022 87

Accessories for FWZ - FWR - FWS

FWZ - FWR - FWSAccessories

Accessories for FWZ/FWR/FWS 02 03 06 08

4-pipe 3-ways 24V on/off valve kit

Kit contains: 1/ 2 pcs of 3way Valve Body SIZE 2÷3 valve = 1/2” (kvs=1,7) SIZE 6÷8 valve = 3/4” (kvs=2,8) 2/ 2 pcs of Electrothermal actuator ON/OFF activation - power supply 24V - total opening time cca 4 minutes - NC (Normally Closed) 3/ Thermal insulation on pipes and valve 4/ 4pcs of lockshield valve

E4M2V03A6 E4M2V06A6 E4M2V10A6

€ 427,- 427,- 449,-

2 pipe 2-ways 24V on/off valve kitcooling h/e

Kit contains: 1/ 2way Valve Body SIZE 2÷6 valve = 1/2” (kvs=1,7) SIZE 8 valve = 3/4” (kvs=2,8) 2/ Electrothermal actuator ON/OFF activation - power supply 24V - total opening time cca 4 minutes - NC (Normally Closed) 3/ without thermal insulation 4/ NO lockshield /shut of valve in the kit

E2M2V207A6 E2M2V210A6

€ 101,- 101,-

2 pipe 2-ways 24V on/off valve kitadditional h/e

Kit contains: 1/ 2way Valve Body SIZE 2÷8 valve = 1/2” (kvs=1,7) 2/ Electrothermal actuator ON/OFF activation - power supply 24V - total opening time cca 4 minutes - NC (Normally Closed) 3/ without thermal insulation 4/ NO lockshield /shut of valve in the kit

E2M2V207A6

€ 101,-2 pipe2-waysproportionalvalve kit oncooling heatexchanger

Kit contains: 1/ 2way Valve Body SIZE 1÷6 valve = 1/2” (kvs=1,7) SIZE 8÷10 valve = 3/4” (kvs=2,8) 2/ Electronic valve actuator Proportional activation - power supply 24V - total opening time cca 8 second - 0-10V control signal 3/ without thermal insulation 4/ NO lockshield /shut of valve in the kit

E2MPV207A6 E2MPV210A6

€ 262,- 262,-2 pipe2-waysproportionalvalve kit onadditionalheatexchanger

Kit contains:1/2way Valve BodySIZE 1.10 valve = 1/2” (kvs=1,7)2/ Electronic valve actuatorProportional activation- power supply 24V- total opening time cca 8 second- 0-10V control signal3/ without thermal insulation4/ NO lockshield /shut of valve in the kit

E2MPV207A6

€ 262,-

2-pipe3-waysproportionalvalve kit

Kit contains:1/ 3way Valve BodySIZE 1.35 valve = 1/2” (kvs=1,7)SIZE 4.10 valve = 3/4” (kvs=2,8)2/ Electronic valve actuatorProportional activation- power supply 24V- total opening time cca 8 second- 0-10V control signal3/ Thermal insulation on pipes and valve4/ 2pcs of lockshield valve

E2MPV03A6 E2MPV06A6 E2MPV10A6

€ 377,- 368,- 379,-

4-pipe3-waysproportionalvalve kit

Kit contains:1/ 2 pcs 3way Valve BodySIZE 1.35 valve = 1/2” (kvs=1,7)SIZE 4.10 valve = 3/4” (kvs=2,8)2/ 2 pcs Electronic valve actuatorProportional activation- power supply 24V- total opening time cca 8 second- 0-10V control signal3/ Thermal insulation on pipes and valve4/ 4pcs of lockshield valve

E4MPV03A6 E4MPV06A6 E4MPV10A6

€ 689,- 695,- 700,-

Air intake & discharge grille

S: Back suction grille fixed fins, made of anodised aluminium complete with filter and galvanised steel plate subframe and recyclable acrylic fibre air filter. D: Discharge grille with double row of anodised aluminium swinging fins, complete with galvanised steel plate subframe.

EAIDF02A6 EAIDF03A6 EAIDF06A6 EAIDF10A6

€ 203,- 245,- 317,- 377,-

Supporting feet

Kit contains:

ESFV ESFVG FWZ FWS2 2

2 2 -

0 1 -

4,2 x 13 mm4 8

2,9 x 9,5 mm 4 4

ESFV06A6 ESFV10A6

€ 25,- 25,-

Supporting feet & grille

ESFVG02A6 ESFVG03A6 ESFVG06A6 ESFVG10A6

€ 36,- 45,- 50,- 70,-

Fresh air intake

To prevent the water from freezing inside the heat exchanger during winter. Close the outdoor air inlet louvre when the system is not operational or use an anti-freeze solution.

EFA02A6 EFA03A6 EFA06A6 EFA10A6

€ 88,- 96,- 106,- 118,-

88

Accessories for FWZ - FWR - FWS

FWZ - FWR - FWSAccessories

Accessories for FWZ/FWR/FWS 02 03 06 08

Rear panel

It is supplied for installation of units, in case rear side can be seen (example: installation at the back of glass windows). Unit, in case of rear panel installation, can not be fixed to wall. Kit consists of: 1. rear upper closing panel 2. rear lower closing panel 3. screws

ERPV02A6 ERPV03A6 ERPV06A6 ERPV10A6

€ 45,- 48,- 59,- 73,-

Plenum box with circular connections (only for FWS-A)

Unit size Plenum box Ø [mm] x nSize 02 EPCC02A6 180 x 2Size 03 EPCC03A6 180 x 2Size 06 EPCC06A6 180 x 3Size 08 EPCC10A6 180 x 4

EPCC02A6 EPCC03A6 EPCC06A6 EPCC10A6

€ 103,- 116,- 146,- 201,-

Vertical auxiliary drainpan

Install it to collect condensationcondensation. Used for vertical FCUs

EDPVB6

€ 8,-

Horizontal auxiliary drainpan

Install it to collect condensation. Used for horizontal FCUs

EDPHB6

€ 8,-

Wired remote controller, Advanced Plus version

All functionality of FWEC1A/2A (see page 66), but additionally: - Management of BLDC fan motor - Management of proportional valve - Weekly timer programmed operating

mode- Configurable digital outputs

FWEC3A

€ 225,-

Split typecontroller

Power control board

FWECSAP

€ 170,-Control panel for remote or on board installation (connected to the power control board) All functionality of FWEC3A, but additionally: - Master & Slave System on Conveyed

Waves (CW)

FWECSAC

€ 129,-

On board mounting kit, for FWEC*A, remote airprobe incl.

To install FWEC1/2/3A thermostat on board. (left or right side) Use it only for FWV / FWZ or FWL / FWR

Side doors on left & right side

ControllersOptional

Low wall unit Flexi type

FWECKA

€ 19,-

Wall mounting kit (spacing collar), for FWEC 1A /2A and 3A

Wall mounting kit (spacing collar), for FWEC 1A /2A and 3A

FWFCKA

€ 13,-Temperature sensor kit, for FWEC*A

FWTSK sensor should be connected to the FWEC*A remote control using the supplied cable as accessory and, in case of prolongations, a shielded cable only. The sensor cable (1.5 m) can be cut to measure if necessary. Sensor must be positioned on the heat exchanger OR at the valve inlet (with or without vlave installation)

FWTSKA

€ 13,-

Relative humidity sensor kit , for FWEC2A and FWEC3A (tempereture sensor kit is required)

Bound together the air temperature remote probe, the installation of the humidity remote probe allows: - To display on the controller the

environment humidity - To select the Dehumidification function

The dehumidification function, available only in the cooling mode, uses the terminal to reduce the environmental humidity by approximately 10% compared to the humidity present at the moment of function selection.

FWHSKA

€ 25,-

Drain pump For FWR only vertical installation CDRP1A

€ 225,-

Applied Systems Price list 2021-2022 89

Air handling unitsA

ir flo

w (m

3 /h x

1,00

0)

0

20

40

50

60

70

80

90

100

120

140

D-AHU Professional

750 m3/hup to 144.000 m3/h

Modular P ʯ Pre-configured sizes ʯ Plug and play concept ʯ EC Fan technology ʯ High efficiency aluminium counter flow plate heat exchanger

ʯ Compact design

D-AHU Modular R D-AHU

Modular P D-AHU Modular L

500 m3/hup to 25.000 m3/h

500 m³/h up to 15.000 m³/h

100 m³/h up to 3.400 m³/h

Professional ʯ Pre-configured sizes ʯ Tailored to the individual customer ʯ Modular construction

Modular R ʯ Pre-configured sizes ʯ Plug and play concept ʯ EC fan technology ʯ Heat recovery wheel (sorption and sensible

ʯ technology) ʯ Compact design

ʯ Modular L ʯ Pre-configured sizes ʯ Plug and play concept ʯ EC Fan technology ʯ High efficiency aluminium counter flow plate heat exchanger

ʯ Low height unit ʯ For false ceiling applications

Products overview

90

Air handling units

Eurovent certificationDaikin Applied Europe S.p.A. participates in the Eurovent Certified Performance programme for Air Handling Units.Check ongoing validity of certificate: www.eurovent-certification.com or www.certiflash.com

Eurovent Classification according to EN1886

Casing strength class

Max. relative deflection mm x m-1D1

4,00

L10,15

L10,22

F90,50

T1U <= 0,5

TB10,75 < Kb <= 1

F81

T20,5 < U <= 1

TB20,6 < Kb <= 0,75

F64

T41,4 < U <= 2

TB40,3 < Kb <= 0,45

F72

T31 < U <= 1,4

TB30,45 < Kb <= 0,6

G1 TO F56

T5No requirements

TB5No requirements

D210,00

L20,44

L20,63

D3EXCEEDING10

L31,32

L31,90

Casing air leakage class at -400 Pa Max. leakage rate (f400) l x s-1 x m-2

Casing air leakage class Max. leakage rate (f700) l x s-1 x m-2

Filter bypass leakage classMax. filter bypass leakage rate k in % of the volume flow rate

Thermal transmittance(U) W/m2 x K

Thermal bridging factor(kb) W x m-2 x K-1

D1

L1

L1

F9

T2

TB2

Energy TermiC° S2

Quickly select your air handling unit by following the wizard:

1 Select the series: D-AHU Professional or D-AHU Modular R

2 Insert the air flow supply and return

3 Insert the summer/winter air supply setpoint

4 Insert the summer/winter outdoor and extract temperature

You will get immediately your 3D result and it’s ready to customize!

Adding or changing the components: coils for the Modular R or filters, recuperators etc for the Professional range.Options as insultation type and metal sheet can be selected.

When finished a technical report, price list, fan curve chart and psychrometric chart can be generated. These final reports can be downloaded in different formats.

Selection softwareASTRA Web ʯ Quick AHU selection that will save you precious time, drastically reducing selection time through the new software interface.

ʯ Very competitive solution available within the Wizard thanks to pre-uploaded parameters.

ʯ High selection quality, thanks to the intelligence embedded with-in the software core.

Applied Systems Price list 2021-2022 91

ALB-R/LB(S)

Premium efficiency heat recovery ventilation unit

ʯ Available in 6 sizes with an air flow up to 3.600 m3/h ʯ Compliant with VDI 6022 ʯ Exceeding ERP 2018 requirement ʯ Reduced energy consumption thanks to EC fans with IE4 motor efficiency

ʯ From 150 Pa up to 500 Pa of external static pressure, depending on the model sizes

ʯ Premium quality counter flow plate heat exchanger with efficiency up to 93%

ʯ Smallest size is 280 mm of height, while the biggest size is 500 mm of height

ʯ Energy saving solution thanks to the 100% automatic bypass ʯ Free-cooling operation and energy efficient defrost logic ʯ Double filter on supply and return, up to F7+F9 filtration level ʯ Possibility to have pre – filter (G4, M5, F7) ʯ CO

2 level management thanks to optional CO

2 sensor

ʯ 50 mm double skin panels, mineral wool insulated ʯ Modbus and BACnet compatible (accessory) ʯ Available also with integrated heating coil (water) ʯ VAM PCB (Smart) ʯ F1/F2 and P1/P2 protocol (Smart) ʯ Fully compatible with SkyAir and VRV systems (Smart) ʯ Direct integration into DIII-net (Smart) ʯ Controlled through any Daikin local, centralized controllers iTAB, iTM, iTC (Smart)

Modular Light / Smart

ALB-R/LB(S)(1) 02 03 04 05 06 07ALB-R/LB € 6.348,- 7.485,- 9.800,- 10.973,- 14.048,- 14.950,-ALB-R/LBS (Smart) € 5.606,- 6.755,- 9.076,- 10.251,- 13.329,- 14.253,-Airflow/Airflow Smart m3/h 300 600 1.200 1.500 2.500/2.300 3.000Thermal efficiency(2)/Thermal efficiency(2) Smart % 93/90 93/91 93/90 92/90 94/92 93/91External static pressure Nom. Pa 100 100 100 100 100 100Current/Current Smart Nom. A 0,52 1,17 1,91 2,48 4,39/3,76 5,39Power input/Power input Smart Nom. kW 0,12 0,27 0,44 0,57 1,01/0,87 1,24SFPv (3) /SFPv Smart kW/m3/s 1,24 1,49 1,25/1,28 1,31/1,32 1,42/1,32 1,46Electrical supply Phase ph 1 1 1 1 1 1

Frequency Hz 50/60 50/60 50/60 50/60 50/60 50/60Voltage V 220/240 Vac 220/240 Vac 220/240 Vac 220/240 Vac 220/240 Vac 220/240 Vac

Dimensions unit Width mm 920 1.100 1.600 1.600 2.000 2.000Height mm 280 350 415 415 500 500Length mm 1.660 1.800 2.000 2.000 2.000 2.000

Weight unit kg 125 180 270 280 355 360Rectangular duct flange Width mm 250 400 500 500 700 700

Height mm 150 200 300 300 400 400Unit sound power level/Unit sound power level Smart dBA 48 54 57 53 62/60 57Unit sound pressure level(4)/Unit sound pressure level Smart dBA 34 39 41 37 46 41

VDI 6022CERTIFIED

Notes: (1) R= right connection and L= left connection; S = Smart Solution (Daikin PCB)

(2) Nominal condition: Outdoor: -10°C (-5°C for Modular Light Smart), 90% Indoor: 22°C, 50%

(3) SFPv is a parameter that quantifies the fan efficiency (the lower it is the better will be). This reduces if airflow decreases.

(4) EN 3744. Surrounding, Directivity (Q) = 2, @1,5m distance

92

Accessories for ALB-R/LB 02 03 04 05 06 07Compact filter (6) G4 ALF02G4A ALF03G4A ALF05G4A ALF07G4A

€ 31,- 37,- 45,- 50,-M5 ALF02M5A ALF03M5A ALF05M5A ALF07M5A

€ 93,- 127,- 174,- 211,-F7 ALF02F7A ALF03F7A ALF05F7A ALF07F7A

€ 96,- 135,- 177,- 214,-F9 ALF02F9A ALF03F9A ALF05F9A ALF07F9A

€ 104,- 143,- 188,- 219,-Silencer 900 mm depth (5) ALS0290A ALS0390A ALS0590A ALS0790A

€ 354,- 518,- 700,- 999,-Probes CO2 ALP00COA

€ 782,-Humidity (%RH) ALP00HUA

€ 450,-Temperature ALP00TEA

€ 93,-Coil module Electric

pre -heatingALD02HEFA ALD03HEFA ALD05HEFA ALD07HEFA

€ 2.081,- 2.171,- 2.894,- 3.791,-Electric post - heating

ALD02HESA ALD03HESA ALD05HESA ALD07HESA€ 2.113,- 2.225,- 3.439,- 3.791,-

Water cooling (post - heating)

ALD02CWSA ALD03CWSA ALD05CWSA ALD07CWSA€ 1.387,- 1.603,- 1.935,- 2.649,-

Water heating (pre/post - heating)

ALD02HWUA ALD03HWUA ALD05HWUA ALD07HWUA€ 627,- 658,- 936,- 1.291,-

Mechanical accessories

Rail ALA02RLA ALA03RLA ALA05RLA ALA07RLA€ 219,- 236,- 267,- 290,-

Rectangular - Circular duct transition (5)

ALA02RCA ALA03RCA ALA05RCA ALA07RCA€ 143,- 216,- 250,- 333,-

Valves 2-way valve water heating

ALV02HW2A ALV03HW2A ALV05HW2A ALV07HW2A€ 84,- 93,- 124,- 135,-

3-way valve water heating

ALV02HW3A ALV03HW3A ALV05HW3A ALV07HW3A€ 104,- 124,- 135,- 143,-

2-way valve water cooling

ALV02CW2A ALV03CW2A ALV05CW2A ALV07CW2A€ 84,- 93,- 124,- 135,-

3-way valve water cooling

ALV02CW3A ALV03CW3A ALV05CW3A ALV07CW3A€ 104,- 124,- 135,- 143,-

Electrical Accessories

Modulating actuator ALE00AMVA€ 385,-

Controls Module bacnet Interface ALC00908A€ 413,-

Module modbus Interface

ALC00902A€ 267,-

Room thermostat (included in the main unit)

ALC00822A€ 177,-

Commissioning module ALC00895A€ 468,-

Notes:

(5) For each unit 4 pcs have to be ordered.

(6) For each unit 2 Number of filters (return air side and Fresh air side) with any combination

Accessories for ALB-R/LBS 02 03 04 05 06 07Compact filter (6) G4 ALF02G4A ALF03G4A ALF05G4A ALF07G4A

€ 31,- 37,- 45,- 50,-M5 ALF02M5A ALF03M5A ALF05M5A ALF07M5A

€ 93,- 127,- 174,- 211,-F7 ALF02F7A ALF03F7A ALF05F7A ALF07F7A

€ 96,- 135,- 177,- 214,-F9 ALF02F9A ALF03F9A ALF05F9A ALF07F9A

€ 104,- 143,- 188,- 219,-Silencer (5) 900 mm depth ALS0290A ALS0390A ALS0590A ALS0790A

€ 354,- 518,- 700,- 999,-Probes CO2 BRYMA200

€ on requestCoil module Electric

pre -heatingALD02HEFB ALD03HEFB ALD05HEFB ALD07HEFB

€ 1.676,- 1.763,- 2.376,- 3.159,-Mechanical accessories

Rail ALA02RLA ALA03RLA ALA05RLA ALA07RLA€ 219,- 236,- 267,- 290,-

Rectangular - Circular duct transition (5)

ALA02RCA ALA03RCA ALA05RCA ALA07RCA€ 143,- 216,- 250,- 333,-

Control Room Thermostat (Not included in the main unit)

BRC1H52W/S/K€ 186,-

Modular Light / Smart

Applied Systems Price list 2021-2022 93

Modular Light / Smart

Electrical heater for Modular L Smart ALD02HEFB ALD03HEFB ALD05HEFB ALD07HEFBPrice € 1.676,- 1.676,- 1.676,- 3.159,-Capacity kW 1,5 3 7,5 15Connectable Modular L Smart size 02 03 04, 05 06, 07Supply voltage 230V,1ph 400V,3ph

ALD-HEFBElectrical heater for Modular L Smart

ʯ Total solution for fresh air with Daikin supply of both Modular L Smart and electrical heaters

ʯ Increase comfort in low outdoor temperature thanks to the heated outdoor air

ʯ Integrated electrical heater concept (no additional accessories required)

ʯ Standard dual flow and temperature sensor ʯ Heater only consumes what is required to pre-heat to the desired minimum fresh air temperature; thus saving energy

NEW

94

Compact filter Silencer CO2 sensor Humidity sensor Electric coil Water coil ( 2&3 way valve)

Compact filter Silencer CO2 sensor Electric coil

* Heating only

*

Accessories

Modular Light

Possible position of the element

Modular Smart

Possible position of the element

RETURN

AIR

RETURN

AIR

EXHAU

ST AIR

EXHAU

ST AIR

SUPPLY A

IR

SUPPLY A

IR

FRESH A

IR

FRESH A

IR

Bottom view

RETURN AIR

SUPPLY AIR

FRESH AIREXHAUST AIR

Modular Light unique features

Heat exchanger

Filtration step

Outer Panel

Fans

Inner Panel

Bypass element Panel Insulation

Premium efficiency counter flow HE

Low pressure compact filter G4, M5, F7 &F9

Pre-painted metal sheet

EC centrifugal plug fan

Aluzinc AZ185

For antifreeze and Free-cooling operation

50 mm panel insulated with mineral wool

Applied Systems Price list 2021-2022 95

Modular P PackageVentilation unit with plate heat exchanger + DX Unit/ R-32 Heat Pump

D-AHU Modular P 1 2 3 4 5 6 7 8 9 10Airflow m3/h 1.100 1.600 2.400 3.100 3.700 4.750 5.500 8.000 10.400 12.500Thermal efficiency % Eurovent 87,5 88,5 88 87,4 86,9 89,1 88,2 86,6 88,7 87,8External static pressure (ESP) Nom. Pa 200 200 200 200 200 200 200 200 200 200Current Nom. A 1,75 2,51 1,28 1,67 2,09 2,69 3,04 4,14 5,88 6,97Power Input Nom. kW 0,4 0,58 0,89 1,15 1,45 1,86 2,11 2,87 4,07 4,83SFPv (specific. Fan power) kW/m3/s 1,32 1,3 1,33 1,34 1,41 1,41 1,38 1,29 1,41 1,39Electrical Supply Phase ph 1 1 3 + N 3 + N 3 + N 3 + N 3 + N 3 + N 3 + N 3 + N

Frequency Hz 50 50 50 50 50 50 50 50 50 50Voltage V 230 230 400 400 400 400 400 400 400 400

Unit dimensions Width mm 720 820 990 1.200 1.400 1.400 1.600 1.940 1.940 2.300Height mm 1.320 1.320 1.540 1.740 1.740 1.920 1.920 2.180 2.460 2.570Length mm 2.030 2.200 2.610 2.660 2.800 3.210 3.340 3.840 4.060 4.190

Unit weight kg 343 358 512 604 785 852 964 1.449 1.700 2.071Eurovent energy classification A+ A+ A+ A+ A+ A+ A+ A+ A+ A+Standard model withcondensing unit ADT 01ECD1 02ECD1 03ECD1 04ECD1 05ECD1 06ECD1 07ECD1 08ECD1 09ECD1 10ECD1

Condensing unit ERQ/VRV IV 140AV1 140AV1 250AW1 2 x 200AW1 2 x 250AW1 2 x 250AW1 2 x RXYQ14U 2 x RXYQ20U 2 x RXYQ22U -Expansion valve kit and control box EKEXV+EKEQ included included included included included included included included included -Package price for Modular P + DX condensing unit € on request on request on request on request on request on request on request on request on request -

Standard model with water chiller ADT 01ECW1 02ECW1 03ECW1 04ECW1 05ECW1 06ECW1 07ECW1 08ECW1 09ECW1 10ECW1Heat pump EWYQ/ EWYT 016CWH-H- 016CWH-H- 032CWH-H- 040CWH-H- 050CWH-H- 064CWH-H- 105B-SSA1 135B-SSA1 205B-SSA2 205B-SSA2Package price for Modular P + heat pump € on request on request on request on request on request on request on request on request on request on request

Highlights › 10 standard sizes › Complies with the hygiene directive VDI 6022 › Operating limits from -25 ° C (-40 ° C with electrical heating) to + 46 ° C ambient temperature

› Plug & Play-arrangement › Monitoring and control possible via Daikin intelligent Touch Manager (iTM)

› Easy installation and commissioning › Optimal specific fan performance (SFP) for efficient system operation

› Up to 92% thermal energy recovery. › Also available without integrated control

Notes: › By default, the Modular P device is suitable for outdoor installation › Easy installation and commissioning › Discounted package price

Selection table Modular PDaikin Fresh air package includes: › Version for indoor exhibition › Connection side on the right › Panel insulation in polyurethane foam › Housing panels in 42mm › Housing sheet outside, powder-coated 0.7mm › Coating inside Aluzinc 0.5mm › Base frame made of aluminium 100mm › Supply Filter: Class F7 ePM1 50% › Return Filter: Class M5 ePM10 55% › Including Minihelic pressure displays › Design of duct connections at supply & return air side with canvas spigot › Including damper on Fresh air and Exhaust air side › Highly efficient counterflow heat exchanger including condensate tray

› Version with control (constant air volume) › HMI device supplied separately

Note: Commissioning price is not included in the package price. Please contact your local Daikin sales staff for selection support and technical data sheets.

2 Packages available with:1. Air-cooled EWYQ-C inverter heat pump (see also p.16):includes: › Standard cold water pump › Option for operation at low outside temperatures down to -15 ° C

or2. Air-cooled R-32 heat pump EWYT-B (see also p.21):includes: › Version” SS “with standard efficiency and standard sound version › With standard cold water pump › With water filter › With soft starter per compressor › With cold water flow switch › With Nordic- Kit › Including rubber vibration damper

96

D-AHU Modular R 1 2 3 4 5 6 7 8 9 10Airflow m3/h 1.600 2.100 3.600 5.300 6.600 7.300 9.900 12.600 14.200 19.200Thermal efficiency % Eurovent 77,4 77,9 77,6 78,2 79,5 78,7 78 78,3 78,9 78,8External static pressure (ESP) Nom. Pa 200 200 200 200 200 200 200 200 200 200Current Nom. A 1,75 2,51 1,28 1,67 2,09 2,69 3,04 4,14 5,88 6,97Power Input Nom. kW 0,4 0,58 0,89 1,15 1,45 1,86 2,11 2,87 4,07 4,83SFPv (specific. Fan power) kW/m3/s 1,32 1,3 1,33 1,34 1,41 1,41 1,38 1,29 1,41 1,39Electrical Supply Phase ph 1 1 1 3 + N 3 + N 3 + N 3 + N 3 + N 3 + N 3 + N

Frequency Hz 50 50 230 50 50 50 50 50 50 50Voltage V 230 230 400 400 400 400 400 400 400 400

Unit dimensions Width mm 720 820 990 1.200 1.400 1.400 1.600 1.940 1.940 2.300Height mm 1.320 1.320 1.540 1.740 1.740 1.920 1.920 2.180 2.460 2.570Length mm 1.700 1.700 1.800 1.920 2.080 2.280 2.400 2.450 2.280 2.400

Unit weight kg 326 351 476 576 751 791 952 1.332 1.412 1.752Eurovent energy classification A A A A A A A A A AStandard model withcondensing unit ADT 01FCD1 02FCD1 03FCD1 04FCD1 05FCD1 06FCD1 07FCD1 08FCD1 09FCD1 10FCD1

Condensing unit ERQ/VRV IV 125AV1 200AW1 250AW1 2 x 200AW1 2 x 250AW1 2 x 250AW1 2 x RXYQ14U 2 x RXYQ18U 2 x RXYQ20U -Expansion valve kit and control box EKEXV+EKEQ included included included included included included included included included -Package price for Modular R + DX condensing unit € on request on request on request on request on request on request on request on request on request -

Standard model with water chiller ADT 01FCW1 02FCW1 03FCW1 04FCW1 05FCW1 06FCW1 07FCW1 08FCW1 09FCW1 10FCW1Heat pump EWYQ/ EWYT 013ACW1P-H- 016CWH-H- 032CWH-H- 040CWH-H- 050CWH-H- 064CWH-H- 085B-SSA1 105B-SSA1 135B-SSA1 175B-SSA1Package price for Modular R + heat pump € on request on request on request on request on request on request on request on request on request on request

Highlights ʯ 10 standard sizes ʯ Complies with the hygiene directive VDI 6022 ʯ Operating limits from -25 ° C (-40 ° C with electrical heating) to + 46 ° C ambient temperature

ʯ Plug & Play-arrangement. ʯ Monitoring and control possible via Daikin intelligent Touch Manager (iTM)

ʯ Easy installation and commissioning ʯ Optimal specific fan performance (SFP) for efficient system operation

ʯ Up to 92% thermal energy recovery. ʯ Also available without integrated control

Notes: ʯ By default, the Modular P device is suitable for outdoor installation ʯ Easy Installation and commissioning ʯ Discounted package price

Selection table Modular RDaikin standard Fresh air package includes: ʯ Version for indoor exhibition ʯ Connection side on the right ʯ Panel insulation in polyurethane foam ʯ Housing panels in 42mm ʯ Housing sheet outside, powder-coated 0.7mm ʯ Coating inside Aluzinc 0.5mm ʯ Base frame made of aluminium 100mm ʯ Supply Filter: Class F7 ePM1 50% ʯ Return Filter: Class M5 ePM10 55% ʯ Including Minihelic pressure displays ʯ Design of Supply and Return duct connections with flexible canvas

ʯ Including damper on Fresh air and Exhaust air side ʯ Highly efficient counterflow heat exchanger including condensate tray ʯ Version WITH control (constant volume flow) ʯ HMI device supplied separately

Modular R PackageVentilation unit with rotary heat exchanger + DX Unit/ R-32 Heat Pump

Note: Commissioning price is not included in the package price. Please contact your local Daikin sales staff for selection support and technical data sheets.

2 Packages available with:1. Air-cooled EWYQ-C inverter heat pump (see also p.16):includes: › Standard cold water pump › Option for operation at low outside temperatures down to -15 ° C

or2. Air-cooled R-32 heat pump EWYT-B (see also p.21):includes: › Version” SS “with standard efficiency and standard sound version › With standard cold water pump › With water filter › With soft starter per compressor › With cold water flow switch › With Nordic- Kit › Including rubber vibration damper

Applied Systems Price list 2021-2022 97

ERQ Inverter heat pump condensing unitsERQ-A

High efficiency inverter heat pump outdoor units for connection to DX heat exchangers in Air Handling Units (AHU) or to CYQ Air Curtains

Outdoor units

Type for 1~ 230V power supply ERQ100AV1 ERQ125AV1 ERQ140AV1Capacity index 100 125 140Nominal cooling capacity kW 11,2 14,0 15,5Nominal heating capacity kW 12,5 16,0 18,0Price € 3.849,- 4.193,- 5.391,-

Type for 3N~ 400V power supply ERQ125AW1 ERQ200AW1 ERQ250AW1Capacity index 125 200 250Nominal cooling capacity kW 14,0 22,4 28,0Nominal heating capacity kW 16,0 25,0 31,5Price € 4.812,- 6.686,- 7.796,-

Notes: - When using for connection to CYQ Air Curtains, select an ERQ outdoor unit with an equal or higher capacity index than the capacity index of the Air Curtain- Specified capacity values are for evaporation temperature = 6 °C (cooling) / condensing temperature = 46 °C (heating), evaporator superheat = 5K,condenser sub-cool = 3K,

on-coil temperature = 27 °CDB / 19 °CWB (cooling) / = 20 °CDB (heating)

Expansion valve kitAllowed heat exchanger capacity [kW] Combinable units

Price €Minimum Maximum ERQ100- ERQ125- ERQ140- ERQ200- ERQ250-

EKEXV63 6,3 7,8 • • 186,-EKEXV80 7,9 9,9 • • • 200,-EKEXV100 10,0 12,3 • • • • 207,-EKEXV125 12,4 15,4 • • • • • 221,-EKEXV140 15,5 17,6 • • • • 227,-EKEXV200 17,7 24,6 • • 244,-EKEXV250 24,7 30,8 • • 263,-

Notes: - An expansion valve kit is a necessary component of the system for AHU applications; it is not necessary for connection to CYQ Air Curtains,- The expansion valve kit needs to be selected based on the nominal design of the AHU heat exchanger,- The AHU heat exchanger needs to be designed for 40bar pressures, with an internal (refrigerant) volume between 0,3 and 8,3 l (not counting headers and distributors)- Specified capacity values are for evaporation temperature = 6 °C (cooling) / condensing temperature = 46 °C (heating), evaporator superheat = 5K,condenser sub-cool = 3K, on-coil temperature = 27 °CDB / 19 °CWB (cooling) / = 20 °CDB (heating)

Unit-specific Accessories

EKEQDCB EKEQFCBA Price €BRC1D52 Basic wired remote controller with weekly timer • • 124,-BRC1H52W/S/K New premium wired remote controller with white/sliver/black color • 186,-KRP4A51 Adaptor for external monitoring/control • 199,-RTD-20 Adaptor for external monitoring/control with 0-10VDC linear capacity control • 471,-KRCS01-1 External room temperature sensor • 95,-KRC19-26 Mechanical cool/heat selector • • 63,-KJB111A Fixing box for cool/heat selector • • 32,-

Notes: - A wired remote controller (Standard or Basic) is required for the EKEQDCB control box; for the EKEQFCBA box, it is optional (required for commissioning and servicing only)- Switching between cooling/heating operation with the EKEQFCBA box must be done from the external control system, or via the optional KRC19-26 Cool/Heat selector

Control box EKEQDCB EKEQFCBAControl type Daikin control Free (External) control

Control options

Room temperature control [via Remote Controller (accessory) or via External room temperature sensor

(accessory)]Return air temperature control (via a supplied thermistor)

• (X-Control): 0~10V direct capacity control (5V = maintain capacity, >5V colder air wanted, <5V warmer air wanted)

• (Y-Control): Fixed evaporation / condensation temperature control

• (W-Control): 0~10V linear capacity control (0V = 0% capacity, 10V = 100% capacity

• Connection ratio 50 ~ 110% (ERQ)Price € 800,- 892,-

Notes: - A control box is a necessary component of the system for AHU applications; it is not necessary for connection to CYQ Air Curtains- A wired remote controller (Standard or Basic) is required for the EKEQDCB control box; for the EKEQFCBA box, it is optional (required for commissioning and servicing only)- Switching between cooling/heating operation with the EKEQFCBA box must be done from the external control system, or via the optional KRC19-26 Cool/Heat selector

98

Daikin rooftops Flexible to suit your application

Rooftop for Retail & Department StoresRetail & department stores need challenging design because of limited space and complex building structure, containing different floors and spaces. Daikin rooftops provide the solution:

› Ductwork can be connected flexibly to optimize installation space.› High efficiency EC plug fans are maintenance free, limiting the downtime of the system for maintenance.› Extraction damper and fan ensure there is no overpressure in the building and air circulation is optimised.› High indoor air quality can be guaranteed thanks to integrated fresh air provision and multiple air filtration

possibilities.

Applied Systems Price list 2021-2022 99

Daikin rooftops

Rooftop for Warehouses & IndustryFor building managers and engineers, warehouses or industrial applications can pose serious HVAC challenges because of their size and unique design. Daikin rooftops provide the solution:

› Indoor/outdoor packaged unit and factory charged refrigerant provide cost-effective installation. › High ESP up to 800Pa allows extensive ductwork to evenly distribute the air across a large space. › Scroll compressor and free cooling ensure highly efficient 24/7 operation. › Clogged filter alarm indicates when filter needs cleaning, ensuring optimum operation and minimized energy consumption.

Plug & play installation as indoor and outdoor are in one package.

Supply and extract ducting ensures even distribution in the building.

100

Wide range of R-32 rooftop units to cover your needs

ʯ Fast delivery

ʯ 3 versions: Base, 2 dampers and 3 dampers

ʯ Thermodynamic heat recovery available on full FC3 range

ʯ Extended capacity up to 190 kW!

ʯ Comes with a wide range of standard integrated features

ʯ Almost infinite configuration possibilities thanks to wide choice of options

ʯ 4 versions: Base, 2 dampers, 3 dampers and 4 dampers

ʯ Thermodynamic heat recovery available on full FC3 range

ʯ Premium efficiency plate heat exchanger available on RS4 range

ʯ Extended capacity up to 190 kW!

ʯ Comes with a wide range of standard integrated features ʯ Easy selection via selection software: rooftop.daikin.eu

48 predefined units readily available from stock Fully customizable units for maximum flexibility

Made-To-Stock units (MTS) Made-To-Order units (MTO)

ErP 2021COMPLIANT

Applied Systems Price list 2021-2022 101

Standard integrated features on all Made-To-Stock and Made-To-Order units

1 R-32 refrigerant ʯ Top sustainability thanks to the use of low GWP

(675) refrigerantʯ Single component refrigerant, easy to re-use and

recycle

2 Inverter driven compressors

ʯ Great year-round seasonal efficiencyʯ Available up to 120 kW models

3 Increased capacity range up to 190 kW!

ʯ More flexibility to tackle larger projects with a small footprint

4 25 mm double skinned panels

ʯ Ensuring long-lasting life and providing good thermal and sound insulation

5 Full color touch displayʯ Intuitive to useʯ Better visualisation of unit parameters

6 Integrated connectivityʯ Direct integration into Daikin intelligent Touch

Manager BMS (via BACNET protocol)ʯ Easy integration in 3rd party BMS systems via

Ethernet port (BACnet TCP/IP & Modbus TCP/IP) or 3-cable port (Modbus over RS485)

7 Selection softwareʯ Easy selection of the correction unit and

options based on location conditionsʯ Direct availability of technical drawings

Select and configure your rooftop now!

rooftop.daikin.eu

More standard integrated features ʯ ISO Coarse 75% filter (G4) (standard for MTS only)

ʯ Standard clogged filter alarm

ʯ Flexible air delivery

ʯ Hydrophilic aluminum fins on indoor and outdoor unit side

ʯ Mesh coil guard on outdoor heat exchanger

ʯ Factory mounted drain pan with heater

ʯ Single operation voltage-free contact

ʯ Power supply connection safety through max/min voltage relay and reversed phase connection

CO

25 kW 190 kW

102

2 damper version, with integrated fresh air

UATYA-BFC2Y1

High installation flexibility and easy servicing

UATYA-BBAY1

ʯ Easy to install ‘plug and play’ concept plus single installation configuration; no additional piping is required since indoor and outdoor sides are pre-connected

ʯ High efficiency and reliable scroll compressor

ʯ Factory pre-charged refrigerant ensures clean and efficient operation

Return air

Return air

Supply air

Supply air

Outdoor section

Return air damper

Fresh air damper Fresh air

ʯ Free cooling with up to 100% fresh air possible

ʯ Improved air quality

ʯ Energy saving using fresh outdoor air to cool the building

ʯ Includes all Base model features

4 versions to choose from

Made-To-Stock units (MTS) Made-To-Order units (MTO)

Made-To-Stock units (MTS) Made-To-Order units (MTO)

HEATING OPERATION EXAMPLE

HEATING OPERATION EXAMPLE

Applied Systems Price list 2021-2022 103

3 damper version, with integrated fresh air and extraction

UATYA-BFC3Y1

ʯ Extraction damper integrated

ʯ Eliminates excessive overpressure in the building

ʯ Including high efficient extraction fan for optimum air circulation in larger buildings

ʯ Thermodynamic heat recovery

ʯ Saves energy by recovering waste heat through the outdoor heat exchanger

ʯ Available on all models

ʯ Includes all FC2 model features

Return air Return air (mixing) damper

Fresh air damperExtraction damper

Thermodynamic heat recovery

Fresh air

Supply air

Made-To-Stock units (MTS)

Made-To-Order units (MTO)

HEATING OPERATION EXAMPLE

104

4 damper version, with integrated fresh air, extraction and plate heat recovery

UATYA-BRS4*

ʯ Premium efficiency counter flow plate heat exchanger ʯ Recovers up to 58% waste heat from the return air ʯ Available in 50% and 100% return air heat recovery

ʯ Bypass damper to allow plate heat exchange or free cooling ʯ Additional thermodynamic heat recovery available up to 50kW models ʯ Includes all FC3 model features ʯ Only available as Made-To-Order model

Return air

Bypass damper Return air (mixing) damper

Fresh air damper (closed)

Supply air

Fresh air

Extraction damper

Made-To-Order units (MTO) only

* Indicative model name. Correct model name to be retrieved from selection software.

PLATE HEAT RECOVERY MODE IN HEATING OPERATION

USE OF BYPASS DAMPER IN FREE COOLING MODE

Return air

Bypass damper (closed) Return air (mixing) damper

Supply air

Plate heat recovery

Fresh airFresh air damper

Extraction damper

Applied Systems Price list 2021-2022 105

EC plug fansize options to allow different ESP values

106

Field applied accessories for Made-To-Stock units

Products overview rooftopsCapacity class (kW)

Type Model MTS Product name Refrigerant Version 25 30 40 50 60 70 80 90 100 110 120 140 150 160 180 190

Air cooled Heat pump

Rooftop unitWith extensive base package for high installation flexibility and easy servicing - ‘Plug and play’ for easy installation - High efficiency - Field convertible return and supply air - Direct integration with Daikin or third party BMS - Factory pre-charged refrigerant

UATYA-BBAY1MTSMTO • • • • • • • • • • • • • • • •

Rooftop unit2 damper version with integrated fresh air - Free cooling with up to 100% fresh air intake - Comes with all Base model features

UATYA-BFC2Y1MTSMTO • • • • • • • • • • • • • • • •

Rooftop unit3 damper version with integrated fresh air and extraction - Integrated extraction damper eliminates over-pressure - Thermodynamic heat recovery, recovering waste heat - Comes with all FC2 model features

UATYA-BFC3Y1MTSMTO • • • • • • • • • • • • • • • •

Rooftop unit4 damper version with integrated fresh air, extraction and plate heat exchanger - Premium efficiency plate heat exchanger, recovering waste heat - Comes with all FC3 model features

UATYA-BRS4* MTO • • • • • • • • • • • • • • • •

MTS - BASE series - UATYA-BBAY1 MTS - FC2 series - UATYA-BFC2Y1 MTS - FC3 series - UATYA-BFC3Y125-30 40-50 60-70 80-120 140-190 25-30 40 50 60-70 80-190 25-30 40-50 60-70 80-120 140-190

Air

trea

tmen

t

Filter ISO Coarse 75% (G4)

2x UATYAC75A + 2x UATYAC75B

(Standard)

3x UATYAC75A + 3x UATYAC75B

(Standard)

6x UATYAC75B(Standard)

12x UATYAC75C(Standard)

12x UATYAC75C(Standard)

2x UATYAC75A

+ 2x UATYAC75B(Standard)

3x UATYAC75A

+ 3x UATYAC75B(Standard)

3x UATYAC75A

+ 3x UATYAC75B(Standard)

6x UATYAC75B(Standard)

12x UATYAC75C(Standard)

2x UATYAC75A +2x UATYAC75B

(Standard)

3x UATYAC75A +3x UATYAC75B

(Standard)

6x UATYAC75B(Standard)

12x UATYAC75C(Standard)

12x UATYAC75C(Standard)

Filter ISO ePM10 50% (M5/F5)

2x UATY-AEPM1050A + 2x UATY-AEPM1050B

3x UATY-AEPM1050A + 3x UATY-AEPM1050B

3x UATY-AEPM1050B

12x UATYAEP-M1050C

12x UATYAEP-M1050C

2x UATY-AEPM1050A + 2x UATY-AEPM1050B

3x UATY-AEPM1050A + 3x UATY-AEPM1050B

3x UATY-AEPM1050A + 3x UATY-AEPM1050B

3x UATY-AEPM1050B

12x UATYAEP-M1050C

2x UATY-AEPM1050A + 2x UATY-AEPM1050B

3x UATY-AEPM1050A + 3x UATY-AEPM1050B

3x UATY-AEPM1050B

12x UATYAEP-M1050C

12x UATYAEP-M1050C

Filter ISO ePM10 70% (M6)

2x UATYAEP-M1070A +2x UATY-

AEPM1070B

3x UATYAEP-M1070A +3x UATY-

AEPM1070B

6x UATY-AEPM1070B

12x UATYAEP-M1070C

12x UATYAEP-M1070C

2x UATYAEP-M1070A +2x UATY-

AEPM1070B

3x UATYAEP-M1070A +3x UATY-

AEPM1070B

3x UATYAEP-M1070A +3x UATY-

AEPM1070B

6x UATY-AEPM1070B

12x UATYAEP-M1070C

2x UATY-AEPM1070A + 2x UATY-AEPM1070B

3x UATY-AEPM1070A + 3x UATY-AEPM1070B

6x UATY-AEPM1070B

12x UATYAEP-M1070C

12x UATYAEP-M1070C

Rigid bag filter ISO ePM1 50% (F7)

2x UATYAEP-M150A +2x UATY-

AEPM150B

3x UATYAEP-M150A +3x UATY-

AEPM150B

6x UATY-AEPM150B

12x UATYAEP-M150C

12x UATYAEP-M150C

2x UATYAEP-M150A +2x UATY-

AEPM150B

3x UATYAEP-M150A +3x UATY-

AEPM150B

3x UATYAEP-M150A +3x UATY-

AEPM150B

6x UATY-AEPM150B

12x UATYAEP-M150C

2x UATYAEP-M150A +2x UATY-

AEPM150B

3x UATYAEP-M150A + 3x

UATYAEPM150B

6x UATY-AEPM150B

12x UATYAEP-M150C

12x UATYAEP-M150C

Rigid bag filter ISO ePM1 85% (F9)

2x UATYAEP-M185A +2x UATY-

AEPM185B

3x UATYAEP-M185A +3x UATY-

AEPM185B

6x UATYAEPM185B

12x UATYAEP-M185C

12x UATYAEP-M185C

2x UATYAEP-M185A +2x UATY-

AEPM185B

3x UATYAEP-M185A +3x UATY-

AEPM185B

3x UATYAEP-M185A +3x UATY-

AEPM185B

6x UATY-AEPM185B

12x UATYAEP-M185C

2x UATYAEP-M185A +2x UATY-

AEPM185B

3x UATYAEP-M185A +3x UATY-

AEPM185B

6x UATY-AEPM185B

12x UATYAEP-M185C

12x UATYAEP-M185C

Cont

rol

UATYACO2P - Duct air quality CO2 probe • • • • • • • • • • • • • • •UATYACAP - Constant air pressure control airflow transducer • • • • • • • • • • • • • • •UATYAWRC - Remote touch screen wired remote controller • • • • • • • • • • • • • • •UATYARRP - Room temperature return probe (incl. housing) • • • • • • • • • • • • • • •UATYASA - Fire and smoke alarm • • • • • • • • • • • • • • •

Oth

er

Rubber antivibration mounts 2x UATYAAVM1

1x UATYAAVM1 + 1x UATYAAVM2

2x UATYAAVM1 + 1x UATYAAVM2

4x UATYAAVM12x UATYAAVM1

+ 2x UATYAAVM22x UATYAAVM1 2x UATYAAVM1

1x UATYAAVM1 + 1x UATYAAVM2

3x UATYAAVM1 + 1x UATYAAVM2

2x UATYAAVM1 + 2x UATYAAVM2

1x UATYAAVM1 + 1x UATYAAVM2

1x UATYAAVM1 + 2x UATYAAVM2

2x UATYAAVM1 + 2x UATYAAVM2

2x UATYAAVM1 + 2x UATYAAVM2

3x UATYAAVM1 + 2x UATYAAVM2

Rainproof hood with anti-intrusion grille UATYARPH1 UATYARPH2 UATYARPH2 UATYARPH3 UATYARPH4 2x UATYARPH1 2x UATYARPH2 2x UATYARPH3 2x UATYARPH4 2x UATYARPH4

* Indicative model name. Correct model name to be retrieved from selection software.

Accessories description Material name Price €Filter ISO Coarse 75% (G4) UATYAC75A 37,-Filter ISO Coarse 75% (G4) UATYAC75B 72,-Filter ISO Coarse 75% (G4) UATYAC75C 68,-Filter ISO ePM10 50% (M5/F5) UATYAEPM1050A 52,-Filter ISO ePM10 50% (M5/F5) UATYAEPM1050B 78,-Filter ISO ePM10 50% (M5/F5) UATYAEPM1050C 78,-Filter ISO ePM10 70% (M6) UATYAEPM1070A 174,-Filter ISO ePM10 70% (M6) UATYAEPM1070B 290,-Filter ISO ePM10 70% (M6) UATYAEPM1070C 256,-Rigid bag filter ISO ePM1 50% (F7) UATYAEPM150A 174,-Rigid bag filter ISO ePM1 50% (F7) UATYAEPM150B 290,-Rigid bag filter ISO ePM1 50% (F7) UATYAEPM150C 256,-Rigid bag filter ISO ePM1 85% (F9) UATYAEPM185A 174,-Rigid bag filter ISO ePM1 85% (F9) UATYAEPM185B 290,-Rigid bag filter ISO ePM1 85% (F9) UATYAEPM185C 256,-Duct air quality C02 Probe UATYACO2P 1.899,-

Accessories description Material name Price €Airflow transducer UATYACAP 572,-Room return probe with housing included UATYARRP 203,-Smoke and Fire detector UATYASA 814,-Optional wired remote controller. Factory mounted controller is present on the unit UATYAWRC 783,-Rubber antivibration mounts UATYAAVM1 125,-Rubber antivibration mounts UATYAAVM2 125,-Rainproof hood UATYARPH1 702,-

Rainproof hood UATYARPH2 1.198,-Rainproof hood UATYARPH3 1.042,-Rainproof hood UATYARPH4 1.405,-Rainproof hood UATYARPH5 1.614,-Rainproof hood UATYARPH6 2.212,-Rainproof hood UATYARPH7 1.244,-Rainproof hood UATYARPH8 1.350,-Rainproof hood UATYARPH9 1.775,-Rainproof hood UATYARPH10 1.933,-

Applied Systems Price list 2021-2022 107

Wide choice of factory-mounted options on Made-To-Order units

Field applied accessories for Made-To-Order units

MTO - BASE series MTO - FC2 series MTO - FC3 series MTO - RS4 series

Cont

rol

UATYACO2P - Duct air quality CO2 probe • • • •UATYACAP - Constant air pressure control airflow transducer • • • •UATYAWRC - Remote touch screen wired remote controller • • • •UATYARRP - Room temperature return probe (incl. housing) • • • •UATYASA - Fire and smoke detector • • • •

Oth

er Rubber antivibration mounts • (1) • (1) • (1) • (1)

Rainproof hood with anti-intrusion grille • (1) • (1) • (1) • (1)

› Filters and rigid bag filters › Multistage filtration possible › From ISO Coarse 75% (G4)

up to ISO ePM1 85% (F9)

› Auxiliary heat sources for additional or complementary heating › Gas burner › Electric coil › Hot water coil

› Pre-heater from heat recovery water coil, to recover waste heat from applications where heat is rejected

› Steam humidifier and post-heating

› Oversized and extraoversized supply and return radial EC plug fans to provide a higher ESP

› Spring return dampers in case of power failure and/or fire alarm

› Anticorrosion treatment on heat exchanger

› Standard or EC axial fan

› Softstarter on compressor for units ≥ 140kW

› Soundproof compartment on compressor

Control options

› BMS gateway via Ethernet: › SNMP & Modbus TCP/IP (standard

BACnet TCP/IP connection can not be used anymore)

› BMS gateway via 3-cable port: › BACnet MS/TP OR Lonworks (standard

Modbus RS485 connection can not be used anymore)

Indoor air treatment Outdoor air treatment

(1) Reference code to be selected in selection software

108

UATYA-BBAY1 25 30 40 50 60 70 80 90 100 110 120 140 150 160 180 190Price € 22.393,- 23.512,- 25.863,- 29.743,- 35.691,- 39.261,- 43.186,- 47.506,- 52.256,- 57.481,- 60.355,- 66.390,- 69.708,- 73.193,- 76.853,- 80.696,-Cooling capacity Nom. kW 25,8 33,4 38,7 45,7 58,8 65,3 74,8 89,8 95,8 108,9 115 133,4 144,7 154,6 171,9 187Heating capacity Nom. kW 25,3 31,1 36,3 46,2 55,1 64,9 68,5 84,2 92,8 101,5 108 123,1 136,4 147,1 157,1 176,9EER 2,83 3,09 3,06 2,96 3,12 2,92 3,09 3,06 2,97 2,99 2,91 3,14 3,02 3,05 3,07 2,97COP 3,22 3,31 3,26 3,24 3,25 3,21 3,37 3,22 3,2 3,35 3,25 3,44 3,33 3,26 3,33 3,27Space cooling Capacity Pdesign kW 25,8 33,4 38,7 45,7 58,8 65,3 74,8 89,8 95,8 108,9 115 133,4 144,7 154,6 171,9 187

SEER 4,62 4,89 5,48 5,34 5,5 4,53 5,56 5,47 5,17 5,29 5,15 4,38 4,26 4,27 4,15 4,08ηs,c % 181,6 192,56 216,12 210,48 217,08 178,08 219,36 215,8 203,72 208,64 203,04 172,08 167,2 167,6 162,84 160,24

Space heating(Average climate)

Capacity Pdesign kW 25,3 31,1 36,3 46,2 55,1 64,9 68,5 84,2 92,8 101,5 108 123,1 136,4 147,1 157,1 176,9SCOP/A 3,35 3,38 3,67 3,65 3,47 3,41 3,7 3,65 3,62 3,56 3,53 3,39 3,36 3,34 3,31 3,34ηs,h % 131 132,16 143,84 142,96 135,6 133,52 145,16 142,96 141,64 139,28 138,28 132,52 131,44 130,76 129,52 130,56

Evaporator Supply side Air discharge direction Frontal, Left Bottom, Right, LeftFan Air flow rate m³/h 4.500 5.800 7.500 9.000 11.000 13.000 14.500 16.500 18.000 19.800 21.600 25.000 26.500 28.000 30.500 31.500

Nominal ESP Pa 300Return side Air intake direction Rear

Thermodynamic heat recovery NoFresh air Standard No

Condenser Air flow rate Cooling m³/h 15.725 16.038 16.374 16.341 31.183 32.203 35.774 37.285 36.195 38.143 36.865 70.704 72.395 67.733 70.200 72.005Refrigerant Type R-32

GWP 675Charge tCO2Eq 4,725 6,750 8,100 10,125 12,150 15,525 16,200 18,900 20,250 24,300 25,650 31,050 33,750

kg 7 10 12 15 18 23 24 28 30 36 38 46 50Dimensions Unit Height mm 1.924 2.374 1.924 2.374

Width mm 2.250Depth mm 2.427 4.317 5.117

Weight Unit kg 1.023 1.077 1.174 1.193 1.739 1.841 2.028 2.086 2.154 2.242 2.252 2.690 2.696 2.738 2.792 2.872Casing Colour RAL 7035Sound pressure level

Cooling dBA TBC 66 68 67,3 69 68,1 72,6 68,7 69,9 70,6 74,2 68,3 68,3 68,7 69,1 70

Sound power level Cooling dBA TBC 84,3 86,8 86,1 88,5 87,5 92,5 88,6 89,8 90,5 94,1 88,6 88,6 89 89,3 90,2Operation range Cooling Min. °CDB -10

Max. °CDB 48Heating Min. °CWB -15

Max. °CDB 26Power supply Phase 3~

Frequency Hz 50Voltage V 400Recommended fuses A 25 40 50 63 80 100 160 200

UATYA-BFC2Y1 25 30 40 50 60 70 80 90 100 110 120 140 150 160 180 190Price € 24.182,- 25.393,- 27.933,- 32.122,- 38.546,- 42.401,- 46.641,- 51.305,- 56.437,- 62.080,- 65.184,- 71.701,- 75.287,- 79.051,- 83.005,- 87.153,-Cooling capacity Nom. kW 25,8 33,4 38,7 45,7 58,8 65,3 74,8 89,8 95,8 108,9 115 133,4 144,7 154,6 171,9 187

With 30% fresh air kW 27,7 35,9 41,5 48,9 63,0 69,9 80,7 96,6 102,7 117,0 122,7 143,1 154,9 165,7 184,2 200,5Heating capacity Nom. kW 25,3 31,1 36,3 46,2 55,1 64,9 68,5 84,2 92,8 101,5 108 123,1 136,4 147,1 157,1 176,9

With 30% fresh air kW 25,6 31,3 36,5 46,3 55,1 65,1 69,2 84,7 94,8 102,1 108,7 124,2 137,5 148,4 158,7 180,2EER With 30% fresh air 2,97 3,26 3,21 3,1 3,28 3,06 3,26 3,24 3,13 3,13 3,03 3,29 3,16 3,19 3,21 3,1 COP With 30% fresh air 3,41 3,56 3,48 3,51 3,47 3,44 3,62 3,47 3,46 3,6 3,48 3,69 3,57 3,5 3,58 3,55 Space cooling Capacity Pdesign kW 25,8 33,4 38,7 45,7 58,8 65,3 74,8 89,8 95,8 108,9 115 133,4 144,7 154,6 171,9 187

SEER 4,62 4,89 5,48 5,34 5,5 4,53 5,56 5,47 5,17 5,29 5,15 4,38 4,26 4,27 4,15 4,08 ηs,c % 181,6 192,56 216,12 210,48 217,08 178,08 219,36 215,8 203,72 208,64 203,04 172,08 167,2 167,6 162,84 160,24

Space heating (Average climate)

Capacity Pdesign kW 25,3 31,1 36,3 46,2 55,1 64,9 68,5 84,2 92,8 101,5 108 123,1 136,4 147,1 157,1 176,9 SCOP/A 3,35 3,38 3,67 3,65 3,47 3,41 3,7 3,65 3,62 3,56 3,53 3,39 3,36 3,34 3,31 3,34 ηs,h % 131 132,16 143,84 142,96 135,6 133,52 145,16 142,96 141,64 139,28 138,28 132,52 131,44 130,76 129,52 130,56

Evaporator Supply side Air discharge direction Frontal, Left Bottom, Right, LeftFan Air flow rate m³/h 4.500 5.800 7.500 9.000 11.000 13.000 14.500 16.500 18.000 19.800 21.600 25.000 26.500 28.000 30.500 31.500

Nominal ESP Pa 300 Return side Air intake direction Rear, Left, Right

Thermodynamic heat recovery NoFresh air Standard Yes

Ratio Standard % 30In free cooling % 100

Condenser Air flow rate Cooling m³/h 15.725 16.038 16.374 16.341 31.183 32.203 35.774 37.285 36.195 38.143 36.865 70.704 72.395 67.733 70.200 72.005Refrigerant Type R-32

GWP 675Charge tCO2Eq 4,725 6,750 8,100 10,125 12,150 12,150 15,525 16,200 18,900 20,250 24,300 25,650 25,650 31,050 33,750 33,750

kg 7 10 12 15 18 18 23 24 28 30 36 38 38 46 50 50Dimensions Unit Height mm 1.924 2.374 1.924 2.374

Width mm 2.250Depth mm 2.943 4.879 5.679

Weight Unit kg 1.150 1.182 1.290 1.349 1.891 1.990 2.218 2.272 2.342 2.430 2.440 2.894 2.904 2.942 2.982 3.060Casing Colour RAL 7035Sound pressure level Cooling dBA TBC 66 68 67,3 69 68,1 72,6 68,7 69,9 70,6 74,2 68,3 68,3 68,7 69,1 70 Sound power level Cooling dBA TBC 84,3 86,8 86,1 88,5 87,5 92,5 88,6 89,8 90,5 94,1 88,6 88,6 89 89,3 90,2 Operation range Cooling Min. °CDB -10

Max. °CDB 48Heating Min. °CWB -15

Max. °CDB 26Power supply Phase 3~

Frequency Hz 50Voltage V 400Recommended fuses A 25 40 40 50 50 63 80 100 100 100 100 160 160 160 200 200

UATYA-BBAY1

UATYA-BFC2Y1

Specifications Made-To-Stock units

Applied Systems Price list 2021-2022 109

UATYA-BFC3Y1 25 30 40 50 60 70 80 90 100 110 120 140 150 160 180 190Price € 28.053,- 29.455,- 32.401,- 37.261,- 44.713,- 49.184,- 54.102,- 59.513,- 65.465,- 72.011,- 75.612,- 83.174,- 87.332,- 91.699,- 96.283,- 101.099,-Cooling capacity Nom. kW 25,8 33,4 38,7 45,7 58,8 65,3 74,8 89,8 95,8 108,9 115 133,4 144,7 154,6 171,9 187

With 30% fresh air kW 27,8 36,1 42,5 49,6 63,7 70,5 81,3 96,8 104,3 118 124,5 145,6 156,8 168,3 186,5 204,4Heating capacity Nom. kW 25,3 31,1 36,3 46,2 55,1 64,9 68,5 84,2 92,8 101,5 108 123,1 136,4 147,1 157,1 176,9

With 30% fresh air kW 26 32,4 38,3 47,7 57,1 68,6 71,6 87,2 97,9 107 112,3 132 147,5 160 173,5 191,6EER With 30% fresh air 2,96 3,2 3,27 3,12 3,23 3 3,21 3,22 3,14 3,11 3,01 3,26 3,14 3,18 3,21 3,14COP With 30% fresh air 3,38 3,48 3,51 3,46 3,4 3,39 3,56 3,45 3,42 3,57 3,4 3,62 3,57 3,49 3,63 3,5Space cooling Capacity Pdesign kW 25,8 33,4 38,7 45,7 58,8 65,3 74,8 89,8 95,8 108,9 115 133,4 144,7 154,6 171,9 187

SEER 4,62 4,89 5,48 5,34 5,5 4,53 5,56 5,47 5,17 5,29 5,15 4,38 4,26 4,27 4,15 4,08 ηs,c % 181,6 192,56 216,12 210,48 217,08 178,08 219,36 215,8 203,72 208,64 203,04 172,08 167,2 167,6 162,84 160,24

Space heating (Average climate)

Capacity Pdesign kW 25,3 31,1 36,3 46,2 55,1 64,9 68,5 84,2 92,8 101,5 108 123,1 136,4 147,1 157,1 176,9 SCOP/A 3,35 3,38 3,67 3,65 3,47 3,41 3,7 3,65 3,62 3,56 3,53 3,39 3,36 3,34 3,31 3,34 ηs,h % 131 132,16 143,84 142,96 135,6 133,52 145,16 142,96 141,64 139,28 138,28 132,52 131,44 130,76 129,52 130,56

Evaporator Supply side Air discharge direction Frontal, Left Bottom, Right, Left, FrontalFan Air flow rate m³/h 4.500 5.800 7.500 9.000 11.000 13.000 14.500 16.500 18.000 19.800 21.600 25.000 26.500 28.000 30.500 31.500

Nominal ESP Pa 300 Return side Fan Air flow rate m³/h 4.500 5.800 7.500 9.000 11.000 13.000 14.500 16.500 18.000 19.800 21.600 25.000 26.500 28.000 30.500 31.500

Nominal ESP Pa 300 Air intake direction Rear RightThermodynamic heat recovery Yes

Fresh air Standard YesRatio Standard % 30

In free cooling % 100Condenser Air flow rate Cooling m³/h 15,725 16,038 16,374 16,341 31,183 32,203 35,774 37,285 36,195 38,143 36,865 70,704 72,395 67,733 70,200 72,005

Refrigerant Type R-32GWP 675Charge tCO 2Eq 4.725 6.750 8.100 10.125 12.150 12.150 15.525 16.200 18.900 20.250 24.300 25.650 31.050 33.750

kg 7 10 12 15 18 18 23 24 28 30 36 38 46 50Dimensions Unit Height mm 1.924 2.374 1.924 2.374

Width mm 2.250Depth mm 3.514 6.317 7.117

Weight Unit kg 1.334 1.367 1.516 1.536 2.184 2.284 2.568 2.610 2.684 2.780 2.790 3.260 3.270 3.311 3.426 3.504Casing Colour RAL 7035Sound pressure level Cooling dBA TBC 66 68 67,3 69 68,1 72,6 68,7 69,9 70,6 74,2 68,3 68,3 68,7 69,1 70 Sound power level Cooling dBA TBC 84,3 86,8 86,1 88,5 87,5 92,5 88,6 89,8 90,5 94,1 88,6 88,6 89 89,3 90,2 Operation range Cooling Min. °CDB -10

Max. °CDB 48Heating Min. °CWB -15

Max. °CDB 26Power supply Phase 3~

Frequency Hz 50Voltage V 400Recommended fuses A 25 40 50 63 80 100 160 200

Specifications Made-To-Order units

All naming in the tables above is valid for Made-To-Stock units only.

For specifications and configuration of Made-To-Order units refer to our selection software.

UATYA-BFC3Y1

Select and configure your rooftop now!

rooftop.daikin.eu

110

Active chilled beamsDadanco active chilled beams (ACB) offer a high cooling capacity up to 315 Watt/

m2 floor space and up to 1.900 Watt per meter length with integrated cooling,

ventilation and heating. ACBs are suitable for integration into all ceiling types at a

reduced ceiling cost compared to passive beams. Also, ACBs significantly reduce

space with smaller duct work, saving space in shafts, plant rooms and ceilings.

This primary air (1) is supplied to the Active chilled beams (A) at a constant flow and pressure and its volume is typically above the minimum ventilation requirement for the space. The primary air must be dehumidified sufficiently to handle all of the room latent loads and can also be cooled or heated to handle a portion of the room sensible loads.

Room thermostat (D) is connected (3) to the unit or zone valve (E) to control the room temperature.

Active chilled beams (A) are continuously supplied with primary air (1) by the central Air Handling Unit (B).The heat exchanger of Active Chilled Beam (A) is supplied with heated or cooled water (2) by heating/cooling unit (C).

Applied Systems Price list 2021-2022 111

Active Chilled beams

Primary Air SystemThere are a number of important issues affected by the primary flow rates, pressure and temperature chosen in the primary air system design including:

ʯ Ventilation Air Requirements

ʯ Primary Air Latent Cooling Capacities

ʯ Risk of Over-cooling/Reheating

ʯ Building Pressurization Control

Choosing the primary air flow rates and temperature requires considerable thought and judgment. Decreasing the primary air temperatures offers the opportunity to decrease fan energy consumption (within the limits of the ventilation air requirement) and increasing latent cooling capacities, while potentially increasing the risks of over-cooling/reheating.

Other design concerns with the primary air system design include:

ʯ Air Handler/Ductwork Zoning and Resetting of Primary Air Temperatures

ʯ Air Distribution Considerations

ʯ Noise Level Requirements

ʯ Heating

Secondary Water SystemThe elevated chilled water temperature entering the active chilled beam secondary water coils must be above the room design dew point temperature to avoid formation of condensate on the coil.

Using the room design temperature of 24 °C db / 17 °C wb (50% relative humidity), the room air dew point temperature is 12.8 °C. In this case, the minimum entering chilled water temperature to the active chilled beams should be above 12.8 °C (typically 14 to 16 °C is used in practice).

Choosing the secondary chilled water temperature is another area requiring considerable thought and judgment.

A higher chilled water temperature will add to the margin of safety relative to condensation concerns and increase the hours when a water-side economizer can be used to serve the active chilled beams, but could have the effect of increasing the fan and pump energy requirements and unit costs.

HeatingThe suitability of the use of overhead heating in any system (Active Chilled Beam, Fan coil, CAV or VAV, etc.) is dependent on the extent of heat losses along the perimeter and this loss determines which discharge arrangements may be appropriate. In general, overhead heating is acceptable if the heat losses are less than 384 W/m along the perimeter.

When using overhead heating, it is also important to minimize the temperature differential between the supply air and the room air, temperature differentials of 8.5 °C or less are recommended.

Regime Room Design Primary Air Water Temp.Cooling 26°C 50% RH 16°C 55% RH 16°CHeating 22°C 50% RH 22°C 55% RH 50°C

1. Net unit sensible cooling & heating capacity can be varied by chaining Primary air pressure from 100 Pa (min) to 175 Pa (max).

2. Below data provided is calculated as per the below regime.

112

Active Chilled beams

ACB40/50Ceiling mounted ACB cassettes

Cassete unit with lateral linear slot discharge, used for heating, cooling and ventilation, 2-way air discharge (ACB40) and 1-way air discharge (ACB50), with horizontal 2 or 4 – pipe heat exchanger, suitable for integration with various ceiling systems. ʯ High cooling and heating capacities with a low primary air flow rate and low sound power level

ʯ Ideally for room height up to 4m ʯ Four nozzle types for most effective induction based on required design conditions

ʯ Removable induced air grill for easy maintenance

ACB40 - 2 pipe Nominal Length(mm) 600 1200 1800 2400 3600Dimension W x H mm 595 x 245Primary Airflow Rate l/s 34 74 117 161 202Supply Airflow Rate l/s 117 255 402 553 692Chilled Water Flow Rate l/s 0,1 0,1 0,1 0,2 0,2Net unit Sensible Cooling capacity* W 1.107 2.442 3.522 4.608 5.443Heating Water Flow Rate l/s 0,05 0,11 0,09 0,16 0,16Net unit Heating capacity* W 1.875 4.264 5.888 7.435 8.379Sound power level dB(A) 24 27 36 42 46

ACB40 - 4 pipe Nominal Length(mm) 600 1200 1800 2400 3600Dimension W x H mm 595 x 245Primary Airflow Rate l/s 34 74 117 161 202Supply Airflow Rate l/s 117 255 402 553 693Chilled Water Flow Rate l/s 0,1 0,1 0,1 0,2 0,2Net unit Sensible Cooling capacity* W 982 2.130 3.251 4.149 5.211Heating Water Flow Rate l/s 0,04 0,08 0,13 0,14 0,16Net unit Heating capacity* W 1.417 3.200 5.188 5.816 6.703Sound power level dB(A) 24 27 36 42 46

ACB50 - 2 pipe Nominal Length(mm) 600 1200 1800 2400 3600Dimension W x H mm 595 x 245Primary Airflow Rate l/s 17 37 59 80 101Supply Airflow Rate l/s 68 145 230 311 389Chilled Water Flow Rate l/s 0,1 0,1 0,1 0,2 0,2Net unit Sensible Cooling capacity* W 662 1.483 2.266 3.051 3.599Heating Water Flow Rate l/s 0,04 0,07 0,09 0,14 0,16Net unit Heating capacity* W 1.187 2.798 4.342 5.714 6.647Sound power level dB(A) 25 25 25 29 33

ACB50 - 4 pipe Nominal Length(mm) 600 1200 1800 2400 3600Dimension W x H mm 595 x 245Primary Airflow Rate l/s 17 37 59 80 101Supply Airflow Rate l/s 68 145 230 311 389Chilled Water Flow Rate l/s 0,1 0,1 0,1 0,1 0,2Net unit Sensible Cooling capacity* W 581 1.284 2.035 2.650 3.176Heating Water Flow Rate l/s 0,04 0,06 0,09 0,1 0,12Net unit Heating capacity* W 950 2.179 3.474 4.078 4.933Sound power level dB(A) 25 25 25 29 33

*Net unit sensible and heating capacity is at a primary air pressure of 175 Pa (max)

Applied Systems Price list 2021-2022 113

Active Chilled beams

ACB30/35Concealed ACB Models

Vertical discharge concealed unit, used for heating, cooling and ventilation, with vertical 2 or 4 – pipe heat exchanger, suitable for integration with suspended ceiling systems. ʯ High cooling and heating capacities with a low primary air flow rate and low sound power level

ʯ Ideally for room height up to 4m ʯ Four nozzle types for most effective induction based on required design conditions

ʯ Removable induced air grill for easy maintenance

ACB30 - 2 pipe Nominal Length(mm) 600 900 1200 1500 1800Dimension W x H mm 226 x 296Primary Airflow Rate l/s 17 28 35 46 57Supply Airflow Rate l/s 63 100 127 165 206Chilled Water Flow Rate l/s 0,1 0,1 0,1 0,1 0,1Net unit Sensible Cooling capacity* W 628 1.034 1.324 1.725 2.094Heating Water Flow Rate l/s 0,04 0,05 0,06 0,08 0,09Net unit Heating capacity* W 1.106 1.891 2.421 3.176 3.927Sound power level dB(A) <15 <15 <15 <15 16

ACB30 - 4 pipe Nominal Length(mm) 600 900 1200 1500 1800Dimension W x H mm 226 x 296Primary Airflow Rate l/s 17 28 35 46 57Supply Airflow Rate l/s 63 100 127 165 206Chilled Water Flow Rate l/s 0,1 0,1 0,1 0,1 0,1Net unit Sensible Cooling capacity* W 558 920 1.155 1.502 1.867Heating Water Flow Rate l/s 0,04 0,04 0,05 0,06 0,08Net unit Heating capacity* W 885 1.447 1.873 2.417 3.080Sound power level dB(A) <15 <15 <15 <15 16

ACB35 - 2 pipe Nominal Length(mm) 600 900 1200 1500 1800Dimension W x H mm 182 x 433Primary Airflow Rate l/s 17 28 35 46 57Supply Airflow Rate l/s 63 100 127 165 206Chilled Water Flow Rate l/s 0,1 0,1 0,1 0,1 0,1Net unit Sensible Cooling capacity* W 628 1.034 1.324 1.725 2.094Heating Water Flow Rate l/s 0,04 0,05 0,06 0,08 0,09Net unit Heating capacity* W 1.106 1.891 2.421 3.176 3.927Sound power level dB(A) <15 <15 <15 <15 16

ACB35 - 4 pipe Nominal Length(mm) 600 900 1200 1500 1800Dimension W x H mm 182 x 433Primary Airflow Rate l/s 17 28 35 46 57Supply Airflow Rate l/s 63 100 127 165 206Chilled Water Flow Rate l/s 0,1 0,1 0,1 0,1 0,1Net unit Sensible Cooling capacity* W 558 920 1.155 1.502 1.867Heating Water Flow Rate l/s 0,04 0,04 0,05 0,06 0,08Net unit Heating capacity* W 885 1.447 1.873 2.417 3.080Sound power level dB(A) <15 <15 <15 <15 16

*Net unit sensible and heating capacity is at a primary air pressure of 175 Pa (max)

114

Active Chilled beams

ACB20 - 2 pipe Nominal Length(mm) 600 1200 1800 2400 3600Dimension W x H mm 595 x 286Primary Airflow Rate l/s 17 37 59 80 101Supply Airflow Rate l/s 68 145 230 311 389Chilled Water Flow Rate l/s 0,1 0,1 0,1 0,1 0,2Net unit Sensible Cooling capacity* W 581 1.284 2.035 2.650 3.176Heating Water Flow Rate l/s 0,04 0,06 0,09 0,1 0,12Net unit Heating capacity* W 950 2.179 3.474 4.078 4.933Sound power level dB(A) 25 25 25 29 33

ACB20 - 4 pipe Nominal Length(mm) 600 1200 1800 2400 3600Dimension W x H mm 595 x 286Primary Airflow Rate l/s 17 37 59 80 101Supply Airflow Rate l/s 68 145 230 311 389Chilled Water Flow Rate l/s 0,1 0,1 0,1 0,1 0,2Net unit Sensible Cooling capacity* W 581 1.284 2.035 2.650 3.176Heating Water Flow Rate l/s 0,04 0,06 0,09 0,1 0,12Net unit Heating capacity* W 950 2.179 3.474 4.078 4.933Sound power level dB(A) 25 25 25 29 33

ACB10 - 2 pipe Nominal Length(mm) 600 1200 1800 2400 3600Dimension W x H mm 433 x 176Primary Airflow Rate l/s 17 37 59 80 101Supply Airflow Rate l/s 68 145 230 311 389Chilled Water Flow Rate l/s 0,1 0,1 0,1 0,1 0,2Net unit Sensible Cooling capacity* W 581 1.284 2.035 2.650 3.176Heating Water Flow Rate l/s 0,04 0,06 0,09 0,1 0,12Net unit Heating capacity* W 950 2.179 3.474 4.078 4.933Sound power level dB(A) 25 25 25 29 33

ACB10 - 4 pipe Nominal Length(mm) 600 1200 1800 2400 3600Dimension W x H mm 433 x 176Primary Airflow Rate l/s 17 37 59 80 101Supply Airflow Rate l/s 68 145 230 311 389Chilled Water Flow Rate l/s 0,1 0,1 0,1 0,1 0,2Net unit Sensible Cooling capacity* W 581 1.284 2.035 2.650 3.176Heating Water Flow Rate l/s 0,04 0,06 0,09 0,1 0,12Net unit Heating capacity* W 950 2.179 3.474 4.078 4.933Sound power level dB(A) 25 25 25 29 33

ACB20Ceiling Mounted ACB Cassette

Cassete unit with lateral linear slot discharge, used for heating, cool-ing and ventilation, 2-way air discharge (ACB20), with two vertical 2 or 4 – pipe heat exchanger, suitable for integration with various ceiling systems. ʯ High cooling and heating capacities with a low primary air flow rate and low sound power level

ʯ Ideally for room height up to 4m ʯ Four nozzle types for most effective induction based on required design conditions

ʯ Removable induced air grill for easy maintenance

ACB10Bulkhead concealed ACB

Horizontal discharge concealed unit, used for heating and cooling and ventilation, with horizontal 2 or 4 – pipe heat exchanger, suita-ble for integration with suspended ceiling systems. ʯ High cooling and heating capacities with a low primary air flow rate and low sound power level

ʯ Ideally for room height up to 4m ʯ Four nozzle types for most effective induction based on required design conditions

ʯ Removable induced air grill for easy maintenance

*Net unit sensible and heating capacity is at a primary air pressure of 175 Pa (max)

Applied Systems Price list 2021-2022 115

116

Products overviewAir cooled chillers, condensing units and Multipurpose units

* (GWP) : R-410A (2.087,5), R-134a (1.430), R-1234ze(E) (7), R-32 (675), R-513A (630) - ** BPHE: Brazed plate heat exchanger***EWAQ032CWN, EWAQ064CWN and EWAQ064CWH are not compliant to Ecodesign Lot21. As alternative to size EWAQ032CWN, equivalent models with low lift pump or high lift pump (EWAQ032CWP/H) can be offered. As alternative to sizes EWAQ064CWN and EWAQ064CWH equivalent model with low lift pump (EWAQ064CWP) can be offered.****Two model sizes EWAD450TZBSS/SL/SR EWAD495TZBSS/SL/SR are not compliant. *****EWAD-T-C is suitable for process cooling application only.

Refr

iger

ant t

ype

*

Refr

iger

ant c

ircu

its

Inve

rter

Free

coo

ling

CompressorWater heat exchanger

Efficiency version Sound version

Swin

g

Scro

ll

Scre

w

Plat

e **

Sing

le p

ass

shel

l an

d tu

be

Stan

dard

Hig

h

Prem

ium

Stan

dard

Low

Redu

ced

Cooling only 0 17,5 200 500 1.000 2.000

EWAQ-BVP R-410A 1 BPHE

EWAA-DV3P-H/DW1P-H NEW R-32 1

BPHE

EWAQ-CWN/P/H*** R-410A 1-2 BPHE

EWAD-CF R-134a 2 EWAD-TZ B**** R-134a 1-2 EWAH-TZ B R-1234ze(E) 1-2 EWAD-T-***** R-134a 2 EWAD-TZ C NEW R-134a 1-2 EWAH-TZ C NEW R-1234ze(E) 1-2 EWAT-B R-32 1-2 Heat pump 0 17,5 200 500 1.000 2.000

EWYQ-BVP R-410A 1 BPHE

EWYA-DV3P-H/DW1P-H NEW R-32 1

BPHE EWYQ-CWN/P/H R-410A 1-2

BPHE SEHVX-BWSERHQ-BW1

R-410A 1 BPHE

EWYD-BZ R-134a 2-3 EWYT-B NEW R-32 1-2 Condensing unit 0 17,5 200 500 1.000 2.000

ERAD-E- R-134a 1 Multipurpose unit 0 17,5 200 500 1.000 2.000

EWYD-4Z R-134a 2

Applied Systems Price list 2021-2022 117

Air cooled chillers, condensing units and Multipurpose units

Refr

iger

ant t

ype

*

Refr

iger

ant c

ircu

its

Inve

rter

Free

coo

ling

CompressorWater heat exchanger

Efficiency version Sound version

Swin

g

Scro

ll

Scre

w

Plat

e **

Sing

le p

ass

shel

l an

d tu

be

Stan

dard

Hig

h

Prem

ium

Stan

dard

Low

Redu

ced

Cooling only 0 17,5 200 500 1.000 2.000

EWAQ-BVP R-410A 1 BPHE

EWAA-DV3P-H/DW1P-H NEW R-32 1

BPHE

EWAQ-CWN/P/H*** R-410A 1-2 BPHE

EWAD-CF R-134a 2 EWAD-TZ B**** R-134a 1-2 EWAH-TZ B R-1234ze(E) 1-2 EWAD-T-***** R-134a 2 EWAD-TZ C NEW R-134a 1-2 EWAH-TZ C NEW R-1234ze(E) 1-2 EWAT-B R-32 1-2 Heat pump 0 17,5 200 500 1.000 2.000

EWYQ-BVP R-410A 1 BPHE

EWYA-DV3P-H/DW1P-H NEW R-32 1

BPHE EWYQ-CWN/P/H R-410A 1-2

BPHE SEHVX-BWSERHQ-BW1

R-410A 1 BPHE

EWYD-BZ R-134a 2-3 EWYT-B NEW R-32 1-2 Condensing unit 0 17,5 200 500 1.000 2.000

ERAD-E- R-134a 1 Multipurpose unit 0 17,5 200 500 1.000 2.000

EWYD-4Z R-134a 2

Cooling capacity (kW)

Heating capacity (kW)

4,1~8,44

16,8~63,2

116~488

400~800

75 ~610

291~2.148

76,3~701

4~8,23

602~1.555

4~8,23

247~580

271~618

400~800

80~650

21,2~63,3

16,8~63,3

16,6~62,9

20,8~62,7

170 - 600

190~1.100

1.200~2.000

700 - 1.600

9.0~14.0

9.0~16.0

11.0~14.0

118

* (GWP) : R-410A (2.087,5), R-134a (1.430), R-1234ze(E) (7), R-32 (675), R-513A (630), R-513A (631), R-515B (293); ** BPHE: Brazed plate heat exchanger;***EWWQ-L-: models < 400 kW all compliant to Ecodesign Lot 21 Tier2. For applications >400 kW possible to use 2 x single module units from EWWQ-G series in stacked arrangement.

Products overviewWater cooled and condenserless chillers

Refr

iger

ant

Type

*

Refr

iger

ant c

ircu

its

Inve

rter

Compressor Water heat exchanger Efficiency versionSound

version

Scro

ll

Scre

w

Cent

rifu

gal

Plat

e **

Sing

le

pass

she

ll

and

tube

Shel

l and

tu

be

Stan

dard

Hig

h

Prem

ium

Stan

dard

Water cooled chillers (Cooling only & Heating only) 0 17,5 200 500 1.000 2.000 21.800

EWWQ-KBW1N R-410a 1-2 EWHQ-G- R-410A 1 EWWQ-G- R-410A 1 EWWQ-L-*** R-410A 2 EWWD-J- R-134a 1

EWWH-J- NEW R-1234ze(E) 1

EWWS-J- NEW R-513A 1 Water cooled chillers (Cooling only) 0 17,5 200 500 1.000 2.000 21.800

EWWD-VZ R-134a 1 Flooded EWWH-VZ R-1234ze(E) 1 Flooded Condenserless chillers 0 17,5 200 500 1.000 2.000 21.800

EWLQ-KBW1N R-410a 1-2 BPHE EWLQ-G- R-410A 1 EWLQ-L- R-410A 2 EWLD-J- R-134a 1

EWLH-J- NEW R-1234ze(E) 1

EWLS-J- NEW R-513A 1 EWLD-I- R-134a 1-2-3 R-513A (GWP 631)

R-515B (GWP 293) Water cooled centrifugal chillers 0 17,5 200 500 1.000 2.000 21.800

EWWD-DZ R-134a 1 EWWH-DZ R-1234ze(E) 1

DWSC/DWDC B/C

R-134aR-513A

R-1234ze(E)R-515B

1 optional Flooded

6,000 RT CENTRIFUGAL R-134a

2per

chiller Flooded

Applied Systems Price list 2021-2022 119

Refr

iger

ant

Type

*

Refr

iger

ant c

ircu

its

Inve

rter

Compressor Water heat exchanger Efficiency versionSound

version

Scro

ll

Scre

w

Cent

rifu

gal

Plat

e **

Sing

le

pass

she

ll

and

tube

Shel

l and

tu

be

Stan

dard

Hig

h

Prem

ium

Stan

dard

Water cooled chillers (Cooling only & Heating only) 0 17,5 200 500 1.000 2.000 21.800

EWWQ-KBW1N R-410a 1-2 EWHQ-G- R-410A 1 EWWQ-G- R-410A 1 EWWQ-L-*** R-410A 2 EWWD-J- R-134a 1

EWWH-J- NEW R-1234ze(E) 1

EWWS-J- NEW R-513A 1 Water cooled chillers (Cooling only) 0 17,5 200 500 1.000 2.000 21.800

EWWD-VZ R-134a 1 Flooded EWWH-VZ R-1234ze(E) 1 Flooded Condenserless chillers 0 17,5 200 500 1.000 2.000 21.800

EWLQ-KBW1N R-410a 1-2 BPHE EWLQ-G- R-410A 1 EWLQ-L- R-410A 2 EWLD-J- R-134a 1

EWLH-J- NEW R-1234ze(E) 1

EWLS-J- NEW R-513A 1 EWLD-I- R-134a 1-2-3 R-513A (GWP 631)

R-515B (GWP 293) Water cooled centrifugal chillers 0 17,5 200 500 1.000 2.000 21.800

EWWD-DZ R-134a 1 EWWH-DZ R-1234ze(E) 1

DWSC/DWDC B/C

R-134aR-513A

R-1234ze(E)R-515B

1 optional Flooded

6,000 RT CENTRIFUGAL R-134a

2per

chiller Flooded

Water cooled and condenserless chillers

2.100-9.000

[ 2 x 10.900 ]

Cooling capacity (kW)

Heating capacity (kW)

790 - 4.500

21.800

449~2.074

329 - 1.540

13,2-183,8

12,5~56,71

110~264

80 - 192

110 - 268

86,5~346

173~676

315~1.433

320~2.173

227~1.415

144~350

105 - 245

140 - 340

120~280

90 - 200

120~270

87,3~352

118~462

93,7~370

187~386

112~468

234~484

16,4~225,5

120

COOLING TOWER70-9.200 kW

On request we can offer you the most suita-ble cooling tower for your application.For correct selection we need following info: ʯ Heat rejection capacity (kW) or chiller type and working conditions

ʯ Liquid inlet and outlet temperature ʯ Liquid type ʯ Maximum/Minimum ambient temperature ʯ Maximum sound level ʯ Space restrictions

AIR COOLER1-162 kW

On request we can offer you the most suitable air cooler for your application based on a brine/water solution.

AIR HANDLING UNIT500-140.000 m3/h

On request we can offer you the most suitable air handling unit for your application. ʯ Air handling units for filtering, heating, cooling, humidifying, and air drying

ʯ Air handling units with heat recovery ʯ Air handling units for outdoor installation

ʯ Air handling units in hygienic execution for hospital and clean room

ʯ Air handling units with indirect gas fired heating

ʯ Air handling units for swimming pool applications

ʯ Air handling units with higher air volumes manufactured on request

ʯ Air handling units with thermal uncoupled frame

DRY COOLER & CONDENSER3-2.400 kW

On request we can offer you the most suitable dry cooler and condenser for your application.For correct selection we need following info: ʯ Heat rejection capacity (kW) or chiller type and working conditions

ʯ Liquid inlet and outlet temperature (dry cooler)

ʯ Liquid type (dry cooler) ʯ Condensing temperature (condenser) ʯ Refrigerant type and number of circuits (condenser)

ʯ Maximum/Minimum ambient temperature

ʯ Maximum sound level ʯ Space restrictions

Total solution products

COMPRESSORInspection/repair/overhaul

InspectionInspection fee/compressor* on request

RepairRepair cost/compressor*

After inspection, on quotation base

OverhaulOverhaul cost/compressor* on request

To extend the lifetime of your compressor, Daikin offers a compressor overhaul service as preventive maintenance.In case of broken compressor, Daikin can offer an inspection to determine whether the compressor is repairable or not. Based on the findings the broken parts will be replaced and the compressor will be restored into operational condition.

Remarks

The above is only valid for DAIKIN semi-hermetic

compressors

* Excluding transport cost and other site related

costs

Applied Systems Price list 2021-2022 121

MENTIONED CAPACITIES, EFFICIENCY RATIOS, SOUND POWER LEVELS, DIMENSIONS Weights are indicative and valid under the following conditions:

Chillers

Air cooled unitsCooling 7 °C / 12 °C water 35 °C ambient tempHeating 40 °C / 45 °C water 7 °C ambient tempHeat recovery 7 °C / 12 °C water 40 °C / 45°C heat recovery 35 °C ambient temp

Condenserless units Cooling 7 °C / 12 °C water 45 °C condensing temp / 5 K subcooling

Water cooled unitsCooling 7 °C / 12 °C evaporator water 30 °C / 35 °C condenser waterHeating 7 °C / 12 °C evaporator water 40 °C / 45 °C condenser water

Condensing unitsCooling: evaporation temperature: 6 °C outdoor temperature: 35 °C on-coil temperature: 27 °CDB / 19 °CWBHeating: condensing temperature: 46 °C outdoor temperature: 7 °C on-coil temperature: 20 °CDB

General:

evaporator superheat: 5K condenser sub-cool: 3K7,5 m equivalent refrigerant piping 0 m level difference

Fan coil units

Cooling:Room temperature DB/WB: 27 °C/19 °CEntering/Leaving water temperature: 7 °C/12 °C

Heating:Room temperature: 20 °CEntering water temperature: 50 °C (2-pipe,water flow rate same as for the cooling) / 70 °C (4-pipe, water temperature leaving 60°C)

Measuring conditions

122

Service Portfolio

Predicting breakdowns ahead of time

The benefits of remote monitoring

Remote Monitoring or control

Daikin Cloud Service is a web-based remote monitoring and control solution for HVAC systems that can even manage the energy consumption of several buildings at once. There’s no need to install any special software. Everything is accessible using a standard browser, whether via a computer or a mobile device.

Analytics

Data is our raw material, and data analytics is our product. The continuous monitoring and analysis of a system’s operating data is not only the key to ensuring efficient operation, cutting operating and maintenance costs and optimizing user comfort. Data analysis also provides further valuable and often surprising insights.

No potential problem goes unnoticed

What’s more, Daikin Cloud Service provides automatic notification if it detects a possible malfunction. This unique predictive notification feature enables service measures to be initiated even before the user notices that a problem has arisen – thus maximizing reliability and minimizing service costs.

Hassle-free connection

We know that connecting a system to the cloud can often be a real challenge – but that‘s no longer your problem. We’ll take care of the connection, including the mobile network and the router, both of which are remotely monitored to maximize infrastructure reliability.

Maximum performance

The performance of even the best system can be impaired if it is not properly operated. Continuous monitoring allows load profiles, usage patterns and operating conditions to be closely followed. The data obtained is the basis for optimizing a system‘s operation and maintenance as well as its return on investment.

Daikin Cloud Service

Our web-based service provides reliable and secure remote monitoring. Our top priority is to earn your trust. Daikin Cloud Service meets the highest security standards in all respects – safeguarding your data privacy as well as transporting and storing your data securely at all times.

Remote Monitoring

ServicesThe latest technology matched with superb service to improve the efficiency and reliability of your HVAC-R installation.

Connected air conditioning works smarter. We offer several ways to

manage your products and installations remotely. From performance

monitoring to predictive logic and analyses and more, our Intelligent

Network is a cost-efficient way to increase the security, uptime and

reliability of your installation.

Applied Systems Price list 2021-2022 123

Higher outlet temperature

Thanks to operation data analysis, we identified the possible comfort issues. Following operation assessment provided the base for taking the countermeasures to increase their comfort.

Real caseReal life examples, how continuous monitoring and data analysis could be useful:

Lower VRV consumption

Thanks to analysis of the VRV systems energy consumption data, we could provide the recommendation, how to change the usage pattern. The result was 20% reduction of electricity costs for cooling and about 15% in heating.

Spare refrigeration capacity

Long term monitoring of the Conveni pack, identified that the client has a 40% spare refrigeration capacity. This allowed to reduce the number of installed devices and thus save the investment costs.

Lower investment costs

Operation data analysis of the old VRV system confirmed, that the replacement capacity and system layout could be optimized. This allowed to decrease investment costs of the replacement system and to resolve comfort issues.

124

Active Monitoring with Daikin on Site

Daikin on Site is a cloud-based monitoring and control tool with a unique range of smart services.

Daikin guarantees the highest levels of support and monitoring with its advanced cloud technology.

BenefitsDaikin on Site is designed to: › Increase uptime and limit unplanned interruptions › Optimise efficiency, reduce energy waste and save running costs

› Extend the service life and reduce wear through incorrect use

› Provide an insight into optimal use of units, including advice from Daikin experts.

Active Monitoring with Daikin on Site for Chiller and Air handling units

Chillers

Optimisation

Air handling units

Remote Monitoring Analyses

Web-based applicationUser-friendly and pre-defined user interface for each user role.The interface can be adapted to specific user needs. This application allows you to monitor and analyse a wide range of information relating to the opearting data from the unit.

Alarm notificationAlarms are communicated in real time (or scheduled if necessary).Alarms are available on the unit controls or the Daikin on Site website and are sent by email to specified people. The assigned user or the responsible service will carry out the necessary checks and analyses in preparation for corrective action.

This package includes: ʯ Modem (factory mounted) is available choosing option 155 during chiller order process

ʯ Data Sim Card ʯ Cloud license ʯ Dedicated report

Overview of functions

Active Monitoring Package

Performance analysisDaikin on Site allows to monitor the working data of the unit in our central cloud server (in the EU). That way we can analyse operating trends and statistical data from units.

This information is available online in the form of interactive graphics, values lists, alarm and event lists.

MODEM (choose Option 155)

DATA SIM CARD

CLOUD LICENCE

REPORT

Applied Systems Price list 2021-2022 125

Active Monitoring with Daikin on Site

What are the main benefits of DoS? ʯ Increases your equipment life-time by having preventive diagnostics features

ʯ Offers running cost reduction possibilities with a dedicated report

What materials need to be ordered to have DoS Active Monitoring?CE.S_DOS_AS_AC_MON for ChillersCE.S_DOS_AH_AC_MON for AHUOPTION 155 – Factory mounted modem

Note that a maintenance contract is mandatory to acquire this service.

Is there a recurring fee?First time investment consists of the following items:

CE.S_DOS_AS_AC_MON for ChillersCE.S_DOS_AH_AC_MON for AHUOPTION 155 – Factory mounted modem

This price includes 1 year Active Monitoring from the date of commissioning: cloud license + dedicated report + sim-card data

In order to continue with the Active Monitoring in the upcoming years the purchase of the following materials is mandatory (i.e this can be seen as a recurring fee):

CE.S_DOS_AS_AC_MON for ChillersCE.S_DOS_AH_AC_MON for AHU

What is the dedicated report offered within the all connected package?It is a tailor-made analysis done by the Daikin engineers on the actual running system. It is to help building owners/managers to identify possible energy saving actions to reduce the running costs.

Is it possible to have DoS - Active Monitoring for more than 1 year?Yes, you can have it by purchasing it for more than 1 year. The price would be:Example: 5 years

Good to know

ACTIVE MONITORING ʯ Increased reliability trough advanced error notification

ʯ Increased comfort by optimized settings ʯ Regularly maintained site ʯ Access to call out / intervention team

Preventive Care

Maintenance Contract

+

Active Monitoring (Materials)

Chiller Active monitoring: Data Sim Card, Cloud licence, report CE.S_DOS_AS_AC_MON

AHU Active monitoring: Data Sim Card, Cloud licence CE.S_DOS_AH_AC_MON

Daikin on Site modem (with antenna) – factory mounted Option 155

Trial session - 1 year for free CE.S_REM_ANALYSIS

Price of CE.S_DOS_AS_AC_MON for Chiller x 5 years Price of CE.S_DOS_AH_AC_MON for AHU x 5 years You can purchase all at once at the beginning to avoid recurring payments.

What is the pricing if there are more than one Chiller/AHU?Example: 5 years Active Monitoring for 5 Chillers

Price of CE.S_DOS_AS_AC_MON x 5 x 5 will give you the total purchasing price. You can purchase all at once at the beginning to avoid recurring payments.

Is having DoS – Active Monitoring possible on an older Chiller/AHU? For all chillers equipped with MT-III (Siemens) controller, DoS can be installed. For units with older controllers (eg. MT-II) it is possible but an additional gateway box is needed. In this case, please contact your Daikin representative.

Can the modem be ordered separately? Yes, it is possible by contacting Daikin Service. However, factory mounted solution is highly recommended as this will save installation and commissioning time on the field.

When is the DoS activated?DoS is activated when the Chiller(s) is commissioned. For the initial report an account with E-Mail is required.

Is it possible to have a trial/free session before investing further?Yes, DoS can be provided for free for the first year in case the following conditions are met:

a. You have ordered a Chiller and/or an AHU with already equipped modem (i.e OPT 155 which is mandatory for all medium and large Chiller ranges) b. The material code CE.S_REM_ANALYSIS is ordered (this is the one year access code).

126

Active Monitoring with Daikin on Site

Why stay with us?After your first year of free monitoring you have now the option to further enjoy the full range of benefits starting from 780,- € per year

Take the advantages of remote monitoring by signing the maintenance contract:

› The yearly report › Your machine is monitored by Daikin 24/7/365 › Remote assistance guaranteed › Daikin takes over the responsibility for the optimum operation of your unit › Energy consumption optimisation › Prevention of breaks › Fast line interaction

and more

Here a sample of a custom made Remote Monitoring Report in English

Daikin always at your side as the best qualified partner.

Applied Systems Price list 2021-2022 127

128

Energy Audit (on-site) Chillers

We offer chiller monitoring and energy audit services in order to supervise your equipment’s

performance, monitor its working parameters and ensure that it runs properly.

Energy audits (on-site) for Chillers

Methodology

Results

Thermal energy Electric power EER / COP

Consumption analysis

Night-time operation

Replacement

Load profile Retrofit

Setpoint resetting

Applied Systems Price list 2021-2022 129

Energy Audit (on-site) Chillers

What does the audit consist of?

Results

Collection of all relevant data about installation, schedules, monitoring systems, impact on demand, invoicing, energy consumption.

On-site measurement gathering and installation of metering kits for subsequent monitoring of variables which determine the thermal energy supplied and the power consumption.

Data about demand and power consumption will allow us to characterise production and analyse the installation.

Applying customer-defined criteria and taking into account the results, several solutions are proposed such as replacement or changes to the monitoring system.

When the existing unit is replaced with the optimised model suggested by the audit, savings and operation of the new unit will be verified and tracked.

VerificationPreliminary data collection Measuring and monitoring Analysis Reporting

ReplacementMeasurement of energy and cost savings derived from replacing technology with an optimised chiller according to the audit results and with an enhanced performance.

Energy consumption analysisEvaluation of air-conditioning cost in relation to the invoiced total, analysis of the daily evolution in power consumption, identifying potential network issues and consumption peaks.

Post-replacement verification and analysisWhen the existing unit is replaced with the optimised model suggested by the audit, savings and operation of the new unit will be verified and tracked.

Retrofit ʯ Oversized equipment? ʯ Power limitation / Replacement with optimised power

ʯ Resetting propulsion setpoint, schedules, timers, ...

In-depth analysis of the installation ʯ Operation outside the designated working hours? ʯ Appropriate control logic? ʯ Schedule resetting?

130

Všeobecné obchodné podmienkyspoločnosti DAIKIN AIRCONDITIONING CENTRAL EUROPE - SLOVAKIA S.R.O. (február 2020)

6. VÝHRADA VLASTNÍCTVA1. Vlastníckym právom k dodanému tovaru disponujeme až do úplnej úhrady všetkých pohľadávok vzniknutých z nášho obchod-

ného vzťahu so Zákazníkom, a to aj v prípade, ak bola kúpna cena za konkrétne stanovené pohľadávky zaplatená. Ak budú dané podmienené výrobky spracované, bezodplatne nadobudneme vlastnícke právo k novému produktu. Ak bude nami dodaný tovar zmiešaný, spracovaný alebo skombinovaný s inými produktmi, Zákazník na nás týmto prevádza, v miere zodpovedajúcej hodnote nášho tovaru, vlastnícke právo alebo spoluvlastnícky podiel na kombinovanom alebo novom výrobku, a to tak k roz-pracovanému, ako aj k hotovému výrobku.

2. Zákazník je oprávnený opätovne predať nami dodaný tovar a výrobky vytvorené prostredníctvom jeho spracovania, zmiešania alebo skombinovania iba v rámci bežnej obchodnej činnosti. Zákazník na nás týmto postupuje akékoľvek pohľadávky vyplýva-júce z takéhoto opätovného predaja, alebo z akéhokoľvek iného právneho titulu voči tretím osobám, vrátane súvisiacich práv, za účelom zabezpečenia našich - budúcich – pohľadávok, ktoré môžu vzniknúť v rámci nášho obchodného vzťahu. Zákazník je povinný zaevidovať postúpenie týchto pohľadávok v jeho účtovníctve najneskôr v čase, keď dôjde k ďalšiemu predaju tovaru.

3. Pred zaplatením kúpnej ceny za tovar je Zákazník oprávnený opätovne predať daný tovar iba v prípade, ak bude zároveň infor-movať ďalšieho kupujúceho (konečného spotrebiteľa) o skutočnosti, že výnos z ďalšieho predaja bol predtým postúpený.

4. Zákazník je oprávnený prijímať úhrady postúpených pohľadávok za predpokladu, že si voči nám plní platobné povinnosti v zmysle ustanovení zmluvy. Zákazník nie je oprávnený iným spôsobom nakladať s podmieneným tovarom (napr. poskytnutie majetku ako zábezpeky, zriadenie záložného práva).

5. Zákazník je povinný nás bezodkladne informovať o zabavení alebo inom zásahu do podmieneného tovaru a / alebo postúpených pohľadávok a  vysvetliť tretej strane, že disponujeme právnym titulom k predmetnému tovaru. Akékoľvek súvisiace náklady bude znášať Zákazník.

6. Všetok hardvér určený pre vzdialené monitorovanie funkčnosti (ERMC), ako sú modemy a dátové/SIM karty, bez ohľadu, či sú nainštalované na/do alebo vmontované do dodaného tovaru alebo sú dodané Zákazníkovi osobitne, zostávajú vlastníctvom Predávajúceho po celý čas. Zákazník má právo tento hardvér používať počas doby, počas ktorej sú mu poskytované služby mo-nitorovania, pričom hardvér musí byť Predávajúceho vrátený ihneď po ukončení služby monitorovania.

7. ZÁRUČNÁ DOBAAk nebude dohodnuté inak a vylučujúc akékoľvek ďalšie nároky, poskytujeme záruku na akékoľvek vady tovaru v čase jeho dodania nasledovne:1. Záručná doba pre jednotlivé kategórie výrobkov je stanovená nižšie a začína plynúť odo dňa dodania zariadenia. Dôkazné bre-

meno, že vada existovala už v čase dodania nesie Zákazník.

KATEGÓRIA VÝROBKU ZÁRUČNÁ DOBAKlimatizácie

Čističky vzduchu; Split; Multi-split; SkyAir; VRV; Packaged; vetracie zariadenia 3 rokyVykurovacie systémy

Altherma vykurovacie čerpadlo a hybridné vykurovacie čerpadlo; domáci zásobník na teplú vodu 3 rokyPlynové a naftové boilery 2 rokySolárne panely 5 rokovPodlažný vykurovací systém (potrubia, panely); Výmenník tepla pre Altherma Hybrid alebo Rotex A1 boiler 10 rokovIné vykurovacie systémy (neuvedené vyššie) 3 roky

Applied SystemsVZT jednotky 1 rokVZT jednotky Modular L; Fan coil jednotky 3 rokyChladiče** 1 rok“Plug&Play” chladiče (EWAQ/EWYQ-A,-B,-C série; SEHVX/SERHQ-B série) 3 roky

ChladenieConveni-Pack*; ZEAS 5 rokovBooster units 3 rokyKomerčné kondenzačné jednotky (CCU; SCU); Zanotti, Tewis, Hubbard, J&E Hall, a Daikin stacionárne chladiace zariadenia *

1 rok

AHT HORECA zariadenia 2 rokyIné chladiace zariadenia (neuvedené vyššie) 3 roky

Riešenia a zariadenia tretej stranyAir curtains 3 rokyOil and Rain-water storage tanks 5 rokovVA Piping 10 rokovLuve*, Güntner* zariadenie 2 rokyDadanco, Cabero, Smart Energy 1 rok

* výlučne za predpokladu, že zariadenie bolo uvedené do prevádzky Predávajúcim alebo osobou na to Predávajúcim autori-zovanou a Predávajúci alebo osoba na to Predávajúcim autorizovaná opätovne uviedla zariadenie do prevádzky po vykonaní významnej opravy (napr. výmera ovládača, kompresora, výmenníkov tepla, atď.), inak sa na tieto zariadenia vzťahu záručná doba 1 rok. **okrem chladičov, u ktorých za účelom poskytnutia záruky, musí vykonať uvedenie do prevádzky Predávajúci.

2. Zákazník si môže uplatniť reklamáciu iba v prípade, ak budú zariadenia nainštalované a zároveň uvedené do prevádzky Predá-vajúcim, alebo spoločnosťou vyškolenou Predávajúcim v súlade s pokynmi na inštaláciu Predávajúceho a ak budú pravidelne udržiavané v zmysle posledných aktuálnych servisných pokynov a/alebo návodu na obsluhu Predávajúceho.

3. Nebude poskytnutá žiadna záruka a/alebo prijatá zodpovednosť v prípade, ak Zákazník nenahlási viditeľné vady prostredníc-tvom písomného oznámenia v lehote 3 pracovných dní od dodania tovaru a akékoľvek ďalšie vady bezodkladne po ich počiatoč-nom zistení.

4. Predávajúci nezodpovedá za vady tovaru, o ktorých Zákazník vedel v čase objednania, resp. dodávky alebo s prihliadnutím na okolnosti, za ktorých sa kúpna zmluva uzavrela musel vedieť.

5. V prípade reklamácie sa zaväzujeme, podľa nášho vlastného uváženia a vhodnosti, buď opraviť vadný tovar alebo diely alebo poskytnúť tovar alebo diely bez vád. Iné záručné nároky akejkoľvek povahy sú vylúčené. Náklady na prácu, čas strávený cesto-vaním, potreby ako prostriedky na zmrazovanie, glykol a mazivá alebo iné náklady (napr. na inštaláciu, dovybavenie) neznáša Predávajúci.

6. Predávajúci môže priebežne poskytnúť aktualizácie softvéru a/alebo hardvéru. Aktualizácie môžu zahŕňať opravy chýb, vylep-šenia a aktualizácie. Aktualizácie sú poskytované Zákazníkovi v strojovo čitateľnej a inštalovateľnej podobe, vrátane pokynov na inštaláciu. Zákazník je povinný inštalovať aktualizácie na jeho vlastné náklady v primeranej lehote. Akákoľvek škoda, ktorá bude spôsobená nenainštalovaním aktualizácie bude výlučnou zodpovednosťou Zákazníka a Predávajúci nepreberá žiadnu zodpovednosť za nenainštalovanie aktualizácie na zariadenie.

7. Okrem prípadov uvedených v odsekoch 2 a 3, záruka a/alebo zodpovednosť sa nevzťahujú na vady, ktoré boli spôsobené ne-vhodným alebo nesprávnym používaním alebo zaobchádzaním, nedodržaním prevádzkových podmienok alebo pokynov na údržbu, nadmerným užívaním alebo nevhodnými prevádzkovými materiálmi alebo náhradnými materiálmi alebo náhradnými dielmi, ktoré neboli dodané Predávajúcim. Záruka sa nevzťahuje na časti, ktorých opotrebovateľnosť je bežnou vlastnosťou, vrátane, ale nielen, filtre, trysky horákov, uhlíkové kefky motorov, spojky, elektródy, ochranné anódy, UV sondy, mreže, olej alebo iný spotrebný tovar.

8. Ak nám nebude poskytnutý požadovaný čas a možnosť prijať všetky potrebné záručné opatrenia, budeme zbavení zodpoved-nosti za reklamácie a náhradu škody. V prípade, ak bude Zákazník pokračovať v používaní vadného tovaru, poskytujeme záruku a/alebo nesieme zodpovednosť iba za pôvodnú vadu. Neuhrádzame žiadne náklady na opravy, ktoré budú vykonané bez nášho výslovného predchádzajúceho súhlasu. Za dôsledky takto vykonaných opráv nenesieme žiadnu zodpovednosť.

9. Záručná doba na náhradné diely a iné vylepšenia je 6 mesiacov od dodania (odovzdania na prepravu prepravcovi).10. Ak bude vada odstránená, na vymenený alebo opravený náhradný diel nezačína plynúť nová záručná doba.11. Vyhradzujeme si právo odmietnuť odstrániť vady v prípade, ak bude Zákazník v omeškaní s plnením jeho platobných záväzkov. 12. V prípade, ak budú dodané a nainštalované výrobky iných výrobcov, záruka je obmedzená na reklamácie, ktoré si môžeme

uplatniť voči dodávateľovi výrobku iného výrobcu. Zákazník nie je oprávnený uplatňovať si žiadne iné reklamácie a nie je opráv-nený požadovať zľavy z kúpnej ceny.

13. Tovar sa môže používať iba v súlade s jeho účelom využitia, súlade s návodom na používanie, resp. inými príslušnými predpismi a pokynmi. Okamihom porušenia tejto povinnosti zanikajú všetky práva vyplývajúce zo záruky poskytnutej Zákazníkovi.

14. Predávajúci je oprávnený požadovať predloženie tovaru (resp. jeho časti), vrátane zlomených, chybných alebo predpokladaných poškodených častí alebo systémov, uplatneného v reklamácii na podrobné prešetrenie. Reklamovaný tovar (resp. jeho časti) je potrebné uchovať pre účely prešetrenia aj v prípade, ak bol nárok uznaný a bol bezplatne poskytnutý náhradný tovar, a to

1. Tieto všeobecné obchodné podmienky (ďalej ako „Podmienky“) vymedzujú základné obchodné podmienky medzi predávajú-cim spoločnosťou DAIKIN AIRCONDITIONING CENTRAL EUROPE - SLOVAKIA s.r.o., sídlo Galvaniho ul. 15/C, 821 04 Bratislava, IČO: 31 400 264, zápis v Obchodnom registri Okresného súdu Bratislava I, odd.: Sro, vl.č.: 9396/B (ďalej aj len „Predávajúci“) a jej obchodným partnerom – právnickou osobou alebo fyzickou osobou - podnikateľom, ktorý pri uzatváraní a plnení zmluvy vystu-puje v rámci svojej obchodnej alebo inej podnikateľskej činnosti, výrobky nakupuje za účelom ich využitia pri podnikaní alebo ďalšej obchodnej činnosti (B2B) (ďalej aj len „Zákazník“) a vzťahujú sa na všetky ponuky, dodávky tovaru a poskytnuté služby, resp. uzatvorené kúpne zmluvy (ďalej aj len „kúpna zmluva“). Tieto Podmienky sa vzťahujú na všetky zmluvné vzťahy medzi Predávajúcim a Zákazníkom, týkajúce sa predaja tovaru a poskytnutých zákazníckych služieb od okamihu uzavretia kúpnej zmluvy, ak v kúpnej zmluve nebolo výslovne dohodnuté inak. Uzavretím kúpnej zmluvy zmluvné strany akceptujú, že vzniknutý záväzkový vzťah sa bude riadiť režimom zákona č. 513/1991 Zb. Obchodný zákonník v platnom znení (ďalej len „Obchodný zá-konník“) a týmito Podmienkami. Neupravené zmluvné vzťahy sa riadia príslušnými právnymi normami slovenského právneho poriadku. Podmienky sú platné pre zmluvné strany v znení platnom v okamihu uzavretia kúpnej zmluvy. Časť I sa vzťahuje na dodávky tovaru. Časť II sa vzťahuje na poskytnutie služieb zo strany nášho zákazníckeho servisu Zákazníkovi. Akékoľvek zmluvy odlišujúce sa od týchto Podmienok sú platné iba v prípade, ak budú z našej strany písomne potvrdené a riadne podpísané. Aké-koľvek neformálne potvrdenia sú neplatné. Obchodné podmienky objednávateľa sa neaplikujú. Prevzatie tovaru sa považuje za súhlas s týmito Podmienkami. Náš zákaznícky servis pre spotrebiteľov (B2C) sa riadi osobitnými všeobecnými obchodnými podmienkami. Naše všeobecné obchodné podmienky sú zverejnené na www.daikin.sk.

2. Vymedzenie niektorých pojmov: „tovar“ znamená tovar patriaci do sortimentu Predávajúceho, najmä klimatizácie, produkty určené na ohrev vody, čistenie

vzduchu a vykurovanie a ich príslušenstvo vyrábané pod značkou DAIKIN, „zmluvné strany“ znamená spolu Predávajúci a Zákazník, „kúpna zmluva“ uzavretá písomným prijatím objednávky Predávajúceho, resp. dodaním tovaru alebo služby Zákazníkovi, pri-

čom objednávka Zákazníka predstavuje návrh kúpnej zmluvy, „objednávka“ znamená jednostranný právny úkon Zákazníka smerovaný Predávajúcemu, s cieľom nadobudnúť tovar alebo

službu, obsahujúca obchodné meno, sídlo, IČO Zákazníka, špecifikáciu druhu a množstva tovaru alebo služby, spôsob odberu a miesto dodania tovaru, služby, kontaktné údaje (tel., email),

„obaly“ znamená veci používané pri manipuláciu s tovarom s cieľom zamedzenia poškodenia tovaru pri dodávke tovaru, najmä papierové, kartónové a drevené obaly, fólie,

„my“ alebo „náš“ znamená Predávajúci, týkajúci sa Predávajúceho.

I. VŠEOBECNÉ OBCHODNÉ PODMIENKY PRE DODÁVKY TOVARU

1. PONUKANaše zverejnené ponuky majú informatívny charakter. Zobrazenie vzorových produktov a akékoľvek informácie o rozmeroch, hmotnosti a technických údajoch sú nezáväzné a podliehajú zmenám vo výrobe a zmenám vzorových produktov. Takého zmeny nepredstavujú vadu tovaru.

2. USKUTOČNENIE OBJEDNÁVKY, ZMENA DODANIA1. Objednávky Zákazníka musia byť uskutočnené v písomnej forme (prostredníctvom listu, faxu, e-mailu alebo prostredníctvom

online objednávkového systému, ktorý je dostupný na www.daikin.sk. Potvrdenie doručenia objednávky zo strany Predávajú-ceho nepredstavuje prijatie objednávky. Za prijatie objednávky sa považuje až naše výslovné písomné prijatie objednávky alebo samotné dodanie objednávky. Akékoľvek ústne alebo telefonické dojednanie alebo dohoda musia byť potvrdené v písomnej forme.

2. Vyhradzujeme si právo na odstúpenie od zmluvy aj v prípade, ak sme už objednávku prijali, a to vtedy, ak medzičasom získané informácie o finančnej situácii Zákazníka nasvedčujú, že Zákazník nebude schopný za objednávku, alebo jej časť, riadne a včas zaplatiť.

3. Po prijatí objednávky si taktiež vyhradzujeme právo zmeniť a zlepšiť dodávku, napr. vo vzťahu k typu a dizajnu tovaru v rozsahu, v akom je možné od Zákazníka očakávať akceptáciu takýchto zmien a zlepšení s ohľadom na naše produktové portfólio tovaru (napr. dodanie rovnocenného alebo prepracovanejšieho zariadenia). Takéto zmeny a zlepšenia sa považujú za vopred odsúhla-sené.

4. Na zrušenie alebo zmenu celej objednávky, alebo jej časti, je potrebný náš písomný súhlas a táto skutočnosť nás oprávňuje úč-tovať Zákazníkovi – okrem už poskytnutých služieb a vynaložených nákladov – poplatok (za zrušenie) vo výške 20 % z hodnoty objednávky (vrátane DPH), minimálne však 250 €. Na určité skupiny tovaru, ktoré sú vyrábané na základe osobitnej objednávky (napr. viacšpirálové, skrutkové chladiče, AHU atď.) sa vzťahujú osobitné pravidlá na zrušenie objednávky, ktoré sú zverejnené na www.daikin.sk.

3. CENY A PLATOBNÉ PODMIENKY1. Ceny sú stanovené v našom platnom cenníku. Cenník je priebežne aktualizovaný. Týmto si vyhradzujeme právo zmeniť ceny aj

v priebehu kalendárneho roka.2. Ceny predstavujú netto ceny bez akýchkoľvek daní, ciel alebo poplatkov v uvedenej mene, vrátane balného, ak nie je uvedené

inak. K cene je potrebné pripočítať dane, clá a poplatky vo výške stanovenej všeobecne záväzným právnym predpisom. Cena tovaru neobsahuje cenu dopravného.

3. Zákazník je povinný zaplatiť nám kúpnu cenu za objednaný tovar a služby dojednanú v kúpnej zmluve. Na základe kúpnej zmluvy bude Zákazníkovi vydaný daňový doklad, resp. faktúra, ktorá obsahuje údaje o nás a Zákazníkovi, právny titul na za-platenie kúpnej ceny, kúpnu cenu bez DPH a  kúpnu cenu bez DPH, dátum vystavenia faktúry, dátum splatnosti peňažného záväzku obsiahnutého vo faktúre, podpis oprávnenej osoby konať v našom mene. Nevystavenie daňového dokladu nemá vplyv na povinnosť Zákazníka zaplatiť nám kúpnu cenu tovaru riadne a včas. V prípade, ak k vystaveniu daňového dokladu zo našej strany nedošlo, je Zákazník povinný uhradiť nám kúpnu cenu najneskôr do 30 dní odo dňa dodania tovaru, a to aj vtedy, ak bol tovar objednaný na základe jednej objednávky dodaný Zákazníkovi po častiach.

4. Neakceptujeme žiadne výhrady k faktúram, ktoré obdržíme viac ako dva týždne po doručení faktúry. Ak nebude uvedené inak, splatnosť faktúr je 30 dní od dátumu doručenia faktúry; dátum splatnosti predstavuje dátum, kedy má byť z našej strany obdr-žaná platba. V prípade omeškania úhrady budeme oprávnení účtovať úrok z omeškania vo výške 12% p.a. V prípade neplnenia sme taktiež oprávnení požadovať úhradu všetkých nákladov súvisiacich s vymáhaním nášho nároku, vrátane, ale nielen, poplat-kov za upomienky a vymáhanie samotného nároku.

5. V prípade, ak bola dohodnutá úhrada v splátkach, bude v prípade omeškania Zákazníka s úhradou čo i len jednej splátky splatná celá dlžná suma.

6. Dodanie tovaru sme oprávnení podmieniť požiadavkou platby vopred. Ak Zákazník nezaplatí riadne a včas, môžeme odmietnuť dodať tovar do doby, kým Zákazník neuhradí dlžnú sumu.

7. Zákazník nie je oprávnený zadržať a ani započítať platby vo vzťahu k záruke alebo iným nárokom.

4. DODACIA LEHOTA1. Zverejnené dodacie lehoty sú informatívne. Uvedené lehoty sa snažíme dodržať a doručiť tovar v čo najkratšom čase. Zákazník

nemá právo trvať na dodržaní určitej dodacej lehoty. Oneskorenie doručenia nezakladá Zákazníkovi právo na náhradu škody a ani právo na odstúpenie od zmluvy. To sa vzťahuje aj na prípady, ak termíny dodania nebudú splnené v dôsledku vyššej moci, štrajku, alebo iných udalostí mimo našej kontroly.

2. Za žiadnych okolností nie je Zákazník oprávnený požadovať od nás úhradu pokuty alebo inej sankcie v prípade nášho omeškania.3. Čiastočné dodávky sú povolené.4. V prípade, ak bude Zákazník v omeškaní s úhradou za predchádzajúcu dodávku, sme oprávnení zadržať dodávky až do zaplate-

nia predchádzajúcej dodávky a nebudeme povinní objednávateľovi v tejto súvislosti nahradiť žiadne vzniknuté škody.

5. PREVZATIE DODÁVKY, PRECHOD NEBEZPEČENSTVA, ONESKORENÉ PREVZATIE1. Ak nebude dohodnuté inak, dodávky budú uskutočňované podľa pravidla CIP (Incoterms 2010) na uvedené miesto určenia.2. Dodanie CIP zahŕňa iba minimálne poistenie prepravy. Dodatočné poistenie prepravy bude zabezpečené iba v prípadoch, ak o to

bude výslovne požiadané zo strany Zákazníka a bude predmetom samostatnej zmluvy, a to na náklady Zákazníka.3. Zákazník je povinný okamžite skontrolovať dodávku preberanú ním, alebo priamo jeho zákazníkmi za účelom zistenia škôd

vzniknutých pri preprave a je povinný zaevidovať akékoľvek poškodenia balenia alebo tovaru v dodacom liste a odmietnuť do-ručovateľovi jej prevzatie. V prípade, ak Zákazník zistí až neskôr, že tovar je poškodený, je povinný nám túto skutočnosť oznámiť bezodkladne, avšak nie neskôr ako do troch pracovných dní od prevzatia tovaru; v opačnom prípade môže zaniknúť možnosť uplatniť si nárok z poistenia.

4. V prípade, ak je Zákazník v omeškaní s prevzatím tovaru, sme oprávnení – bez ohľadu na naše ďalšie práva – účtovať mu daný tovar ako prevzatý, alebo iným spôsobom s ním naložiť bez stanovenia časového limitu. Ak s tovarom naložíme iným spôsobom, čas na doručenie začne plynúť v deň, kedy nám bude doručená písomná žiadosť Zákazníka o doručenie tovaru.

5. Sme oprávnení účtovať Zákazníkovi akékoľvek náklady, ktoré vznikli z dôvodu oneskoreného prevzatia, vrátane, ale nielen, akýchkoľvek nákladov na uskladnenie, čakacie doby, atď.

Applied Systems Price list 2021-2022 131

Všeobecné obchodné podmienky Predávajúceho sú dostupné aj na internete na www.daikin.sk

DAIKIN AIRCONDITIONING CENTRAL EUROPE - SLOVAKIA s.r.o., sídlo Galvaniho ul 15/C, 821 04 Bratislava, IČO: 31 400 264, zápis v Obchodnom registri Okresného súdu Bratislava I, oddiel: Sro, vl.č.: 9396/B

telefón +421 2 57103211, fax +421 2 57103299, [email protected], https://www.daikin.sk/

najmenej počas 3 mesiacov od uznania oprávnenosti reklamácie. V prípadoch, keď prešetrovanie odhalí, že nárok na záruku je neopodstatnený a záruka je preto zamietnutá (napr. časť bola poškodená vonkajšími faktormi, nedostatok údržby, časť funguje správne atď.), Predávajúci si môže uplatniť nárok na náhradu nákladov spojených s prešetrovaním, prepravou, ako aj náklady na tovar, ktorý bol v rámci riešenia reklamácie bezplatne poskytnutý.

8. ZODPOVEDNOSŤ 1. Zodpovednosť za škodu nesieme iba v prípadoch, ak sme preukázateľne konali úmyselne alebo s hrubou nedbanlivosťou. Od-

mietame akúkoľvek zodpovednosť za ľahkú nedbanlivosť. Zodpovednosť nenesieme predovšetkým za následné škody (napr. prestoje v dôsledku nesprávnych dodávok) a finančné strany, ušlý zisk, nedosiahnuté úspory, stratu záujmu a vzniknuté škody z nárokov tretích strán voči Zákazníkovi, ak vyššie uvedené nie je v priamej súvislosti s našim úmyslom alebo hrubou nedbanli-vosťou. V prípade vzniku škody v dôsledku chybného stavu tovaru, ktorý nám bol dodaný, nesieme zodpovednosť iba v rozsahu, v akom ju nesie jeho výrobca alebo dodávateľ voči nám. Naša zodpovednosť v žiadnom prípade nesmie prekročiť hodnotu fak-túry za daný tovar.

9. ZÁRUKA1. Zodpovednosť Predávajúceho zanikne, ak údržba, ako je určená Predávajúcim, nebola vykonaná vôbec alebo včas alebo nebola

vykonaná spoločnosťou autorizovanou Predávajúcim a ak Zákazník nedodržal Predávajúcim určené intervaly na vykonanie ser-visu a údržby. Bremeno preukázania riadne a včas vykonanej údržby a čistenia znáša Zákazník. Zodpovednosť Predávajúceho zanikne aj vtedy, ak Zákazník používa príslušenstvo, ktoré nebolo schválené Predávajúcim alebo ak tretia osoba, ktorá nebola autorizovaná Predávajúcim, vykonala zásah do zariadenia a vykonala zmeny na dodaných produktoch. Trecie časti zariadení sú vylúčené zo zodpovednosti za vady.

10. UKONČENIE KÚPNEJ ZMLUVY1. Kúpna zmluva sa končí dňom vysporiadania všetkých práv, povinností a nárokov zmluvných strán z nej vyplývajúcich. Pred touto

dobou je možné kúpnu zmluvu ukončiť dohodou zmluvných strán alebo odstúpením v súlade s týmto článkom. Predávajúci je oprávnený od zmluvy odstúpiť:

a) ak kupujúci je v omeškaním zo zaplatením kúpnej ceny tovaru, a to aj napriek písomnej výzve predávajúceho na jej uhradenie v primeranej dodatočnej lehote,

b) po uzatvorení kúpnej zmluvy s kupujúcim vznikli preukázateľné skutočnosti na strane kupujúceho, ktoré odôvodňujú opráv-nené pochybnosti o možnostiach skorého a úplného plnenia všetkých povinností a záväzkov zo strany kupujúceho, hlavne vo vzťahu ku zaplatení kúpnej ceny, je predávajúci oprávnený od kúpnej zmluvy a dodania tovaru odstúpiť, resp. požadovať na kupujúcom okamžitú úhradu kúpnej ceny tovaru nezávislú na údajoch uvedených na faktúre,

c) nebola ani v primeranej dodatočnej lehote uhradená kúpna cena pred dodaním tovaru v súlade s týmito Podmienkami d) v ostatných prípadoch, keď to umožňujú tieto Podmienky, kúpna zmluva alebo platné všeobecne záväzné právne predpisy. 2. Odstúpením kúpna zmluva zaniká od počiatku. Platnosť kúpnej zmluvy sa končí v momente doručenia odstúpenia Predáva-

júceho Zákazníkovi. Odstúpením od kúpnej zmluvy nezanikajú práva a povinnosti, ktoré vznikli v dôsledku porušenia kúpnej zmluvy, a to najmä nárok na náhradu škody, zmluvné pokuty a iné sankcie, ušlý zisk a pod.

3. Zákazník je v prípade odstúpenia povinný na vlastné náklady dopraviť tovar predávajúcemu. V prípade, že tak neurobí, je Pre-dávajúci na náklady Zákazníka oprávnený tovar odobrať a dopraviť aj sám. Zákazník je povinný tovar odovzdať predávajúcemu v pôvodnom stave, t.j. v stave ku dňu prevzatia a odovzdania tovaru, s prihliadnutím na obvyklé opotrebovanie. Ak Zákazník poruší túto svoju povinnosť, Predávajúci je oprávnený tovar uviesť do pôvodného stavu na náklady Zákazníka, pričom nezodpo-vedá za žiadnu škodu, ktorá by týmto postupom Zákazníkovi mohla vzniknúť. Vrátenie alebo odobratie tovaru podľa predchá-dzajúceho ustanovenia nemá vplyv na povinnosť Zákazníka zaplatiť kúpnu cenu tovaru v plnej hodnote.

11. VRÁTENIE TOVARU1. Tovar je možné vrátiť alebo vymeniť iba na základe nášho výslovného súhlasu v písomnej forme. Vrátiť je možné tovar iba

v minimálnej hodnote 100.00 € netto za jednu položku a maximálnej hodnote 50.000,00 € netto za položku a iba v prípade, že predmetný tovar nie je poškodený, nebol používaný, je v pôvodnom obale a je možné ho opätovne predať. Najmä nie je povolené vrátenie už nainštalovaných jednotiek (vrátane chladičov) a vrátenie akýchkoľvek jednotiek vyhotovených na objednávku ako aj náhradných dielov.

2. Zákazník je povinný vyplniť formulár „Žiadosť o vrátenie tovaru” (k dispozícii na stránke Predávajúceho https://my.daikin.eu) a zaslať nám ho na nami poskytnuté faxové číslo alebo na e-mailovú adresu v lehote 10 kalendárnych dní po dodaní. V opačnom prípade vrátenie predmetného tovaru nebudeme akceptovať.

3. Tovar musí byť vrátený na nami určené miesto s uhradením prepravného a na riziko Zákazníka. 4. V každom jednom prípade vrátenia tovaru bude Zákazníkovi uhradených maximálne 80% z nami účtovanej netto kúpnej ceny

Zákazníkovi. Všetky štandardné vrátenia podliehajú poplatku vo výške 20% za opätovné naskladnenie / administratívu.5. Všetky vrátenia tovaru budú z našej strany skontrolované. V prípade, ak bude tovar vrátený nesprávnym spôsobom (t.j. nie

v súlade s ods. 1 vyššie), sme oprávnení odmietnuť takéto vrátenie a vrátiť tovar Zákazníkovi na riziko a náklady Zákazníka. Prípadne môžeme účtovať vyšší poplatok opätovné naskladnenie / administratívu ako uvedených 20%.

6. Dobropisy akejkoľvek povahy budú výlučne započítané s budúcimi dodávkami.

12. INŠTALÁCIAJe na zodpovednosti Zákazníka, aby nainštaloval a uviedol do prevádzky tovar a aby zabezpečil, aby jeho zamestnanci, zástupcovia a subdodávatelia, alebo akékoľvek osoby, ktoré Zákazník využije na inštaláciu a uvedenie tovaru do prevádzky, boli riadne vyškolení na túto činnosť a aby konali v súlade s ustanoveniami akýchkoľvek pokynov alebo príručiek dodávaných s tovarom.

13. ŽIVOTNÉ PROSTREDIE, LICENCIE1. Zákazník nesie zodpovednosť za všetky náklady, poplatky a výdavky, ktoré mu vzniknú alebo ktoré budú súvisieť s vyradením,

obnovou, recykláciou a likvidáciou všetkých tovarov, alebo ich časti a nie je oprávnený domáhať na úhrady takto vzniknutých nákladov alebo poskytnutia príspevku z našej strany.

2. Zákazník nesie zodpovednosť za získanie a dodržanie všetkých príslušných licencií, oprávnení, povolení a súhlasov od prís-lušných regulačných orgánov a za dodržiavanie akýchkoľvek zákonných požiadaviek v súvislosti so skladovaním, inštaláciou, prevádzkou, používaním, údržbou, opravami, prepravou, vyradením, obnovou a prípadnou likvidáciou tovaru.

3. V prípade, ak Zákazník predá všetok tovar, alebo jeho časť inému subjektu, Zákazník je oprávnený uzatvoriť obdobné dojedna-nie s daným subjektom.

14. DÔVERNOSŤ1. Všetky informácie a / alebo poradenstvo, či už písomné alebo ústne, či už vo vzťahu k tovaru alebo k nášmu podnikaniu, ktoré

sme poskytli Zákazníkovi, nesmú byť oznámené tretej strane bez nášho predchádzajúceho písomného súhlasu okrem prípadov, kedy predmetné informácie a / alebo poradenstvo budú verejne dostupné a ktoré sa stali dostupnými iným spôsobom, ako porušením tejto povinnosti, alebo ktorých uverejnenie podlieha zákonnej povinnosti.

2. Zákazník je povinný bezodkladne nám oznámiť akékoľvek zverejnenie vyžadované zákonom a z našej strany sme oprávnení hľadať vhodný nástroj, aby bolo takémuto zverejneniu zabránené. Zákazník sa týmto zaväzuje s nami plne spolupracovať (na náklady Zákazníka) v prípade, ak odmietneme takúto požiadavku.

15. PRÁVA DUŠEVNÉHO VLASTNÍCTVA1. Zákazník nemá právo na nami vlastnené duševné vlastníctvo alebo duševné vlastníctvo, na ktoré nám bola poskytnutá licencia. 2. Zákazník nesmie pripustiť, aby bola odstránená alebo prekrytá akákoľvek ochranná známka, inštrukcia alebo upozornenie

uvedené na tovare. 3. Všetky návrhy, vzorky, modely, experimentálne zariadenia, marketingové zariadenia, príslušenstvo a ďalšie predmety vzťahu-

júce sa k tovaru alebo jeho vývoju alebo výrobe sú našim majetkom, musí byť s nimi zaobchádzané ako s dôvernými a nesmú byť kopírované, reprodukované a ani sprístupňované žiadnym osobám bez nášho predchádzajúceho písomného súhlasu.

16. OSOBNÉ ÚDAJE1. Osobné údaje Zákazníka, ktoré sme získali pri uskutočňovaní objednávky, budú elektronicky uložené a spracované za účelom

vybavenia objednávky, dodania tovarov a služieb Zákazníkovi, riadenia vzťahov so Zákazníkom, pre naše vnútorné účtovné potreby a procesy a na právne a regulačné účely. Pre niektoré z týchto účelov budeme musieť zdieľať údaje Zákazníka s tretími stranami, avšak vždy zabezpečíme, aby boli údaje považované za dôverné a chránené danými tretími stranami.

2. Zákazník súhlasí s tým, že sa môžeme obrátiť na agentúry úverových referencií a/alebo spoločnosti na poistenie úverov, aby uskutočnili vyhľadávanie týkajúce sa úverov alebo kontrol voči Zákazníkovi, aby bolo možné posúdiť finančnú situáciu Zákaz-níka a zároveň súhlasí s tým, že sme oprávnení poskytnúť na tieto účely údaje o Zákazníkovi (meno, adresa, kontaktné údaje, meno vlastníka, údaje o objednávke, história objednávok, platobná disciplína, bilancia Zákazníka) najmä spoločnosti Atradius Credit Insurance N.V., Zweigniederlassung Österreich, CRIF GmbH, Österreich, Akzepta Inkasso Gmbh alebo inej.

3. Zákazník zároveň súhlasí s tým, že naša spoločnosť a ostatní členovia našej skupiny (tak, ako sú uvedení na www.daikin.com) sú oprávnení použiť osobné údaje Zákazníka (meno, adresa, kontaktné údaje v objednávke a história objednávok) aj pre naše vlastné marketingové účely a kontaktovať Zákazníka prostredníctvom telefónu, e-mailom alebo SMS alebo inou formou pos-lania správy o našich produktoch a službách, ktoré môžu byť pre Zákazníka zaujímavé. Zákazník je oprávnený tento súhlas kedykoľvek odvolať. Podrobné informácie nájdete v našich B2B & B2C pravidlách o ochrane osobných údajov, ktoré možno nájsť na www.daikin.sk.

17. SÚDNA PRÁVOMOC, ROZHODNÉ PRÁVO1. Všetky spory vyplývajúce z tejto zmluvy alebo s ňou súvisiace budú predložené na rozhodnutie všeobecným súdom Slovenskej

republiky.2. Všetky zmluvy uzatvorené z našej strany a všetky spory vzniknuté v súvislosti s týmito zmluvami sa budú riadiť a vykladať

v súlade so slovenským právom s vylúčením jeho kolíznych noriem a Dohovoru OSN o kúpe tovaru.

18. ODDELITEĽNOSŤV prípade, aj bude akékoľvek ustanovenie týchto všeobecných obchodných podmienok alebo akejkoľvek zmluvy uzatvorenej medzi nami a Zákazníkom neplatné alebo neúčinné, táto skutočnosť nebude mať vplyv na ostatné ustanovenia týchto dokumentov. Ne-platné ustanovenia budú nahradené ustanoveniami, ktoré budú v súlade so zákonom a ktoré budú najvernejšie vyjadrovať zámer zmluvných strán.

II. VŠEOBECNÉ OBCHODNÉ PODMIENKY PRE POSKYTOVANIE SLUŽIEB

Nižšie uvedené podmienky sa vzťahujú na služby poskytované našim zákazníckym servisom, ako je inštalácia, uvedenie do prevádz-ky, inšpekcia a riešenie problémov, opravy a údržba, poskytovaným Zákazníkovi.

1. ROZSAH POSKYTOVANÝCH SLUŽIEB1. Presný rozsah nami poskytovaných služieb je uvedený v našej písomnej ponuke alebo v našom písomnom prijatí objednávky.

Akékoľvek ďalšie služby, ktoré nie sú výslovne uvedené v ponuke a/alebo v prijatí objednávky a ktoré budú poskytnuté z našej strany na žiadosť Zákazníka, budú účtované samostatne v zmysle nášho cenníka. Uvedené sa vzťahuje aj na prípady, ak z ohliad-ky na mieste samom vyplynie, že je potrebné poskytnutie ďalších služieb.

2. V prípade diaľkových monitorovacích jednotiek bude náš zákaznícky servis konať iba na základe pokynu od Zákazníka, alebo ak takáto požiadavka bola vopred písomne dohodnutá.

3. Služby poskytujeme výlučne na nami dodané a/alebo vyrobené zariadenia a diely jednotiek. Rozsah služieb preto nezahŕňa testovanie dielov od iných dodávateľov, skúšku tesnosti prívodných potrubí vytvorených Zákazníkom, skúšku elektrického napájania a/alebo prípojok a hydraulické nastavovanie jednotky. V prípade jednotiek zložených z iných dielov naše služby ne-zahŕňajú inšpekciu celej jednotky. Predovšetkým nebudeme kontrolovať, či je zariadenie kompletné a či sú jeho bezpečnostné diely v súlade s príslušnými predpismi a ich najnovším vývojom.

4. Nie sme povinní kontrolovať, či sú poskytnuté informácie a dokumenty zo strany Zákazníka (napr. popisy jednotiek, schémy) správne.

2. ODHADY NÁKLADOV1. Odhady nákladov sú informatívne, a nie sú záväzné.2. V prípade, ak bol z našej strany poskytnutý odhad nákladov alebo ponuka balíčka, vyžiadame si od Zákazníka predchádzajúci

súhlas vo vzťahu k akýmkoľvek potrebným dodatočným prácam, ktoré je možné určiť pri realizácii, ktoré sú potrebné na spre-vádzkovanie a ktoré prevyšujú 10% z celkovej ceny.

3. POVINNOSŤ SPOLUPRÁCE1. Zákazník je povinný zabezpečiť, aby akákoľvek spolupráca z jeho strany, ktorá je nevyhnutná na poskytovanie služieb z našej

strany bola poskytnutá včas a bezplatne.2. Zákazník je predovšetkým povinný zabezpečiť prístup k jednotkám tak, ako to bude požadované. Zákazník je povinný splniť na

jeho vlastné náklady všetky potrebné technické požiadavky (napr. zdroje energií) s výnimkou prípadov, kedy majú byť takého požiadavky splnené z našej strany na základe osobitnej dohody. Zákazník je povinný zabezpečiť, aby bolo príslušné pracovisko dostatočne osvetlené. V prípade, ak to bude potrebné, Zákazník je povinný zabezpečiť rebríky a lešenia za účelom umožnenia bezpečného prístupu našich zamestnancov na pracovisko. Pracovisko musí byť ľahko dostupné vozidlom zákazníckeho servisu.

3. Zákazník je povinný zabezpečiť, aby boli diaľkové monitorovacie jednotky spojené s telekomunikačnou sieťou.4. Zákazník je povinný poskytnúť všetky potrebné informácie a podklady s cieľom umožniť hladké poskytovanie dohodnutých

služieb. Pred začiatkom poskytovania služieb je Zákazník predovšetkým povinný oznámiť akékoľvek zmeny uskutočnené ním, alebo tretími osobami v štandardných nastaveniach, kontrolnom systéme a iných parametroch ako aj poškodenia jednotky, o ktorých má Zákazník vedomosť.

5. Po uvedení jednotky do prevádzky je Zákazník povinný splniť požiadavky uvedené v súvisiacich podmienkach našej spoločnosti.6. V prípade, ak Zákazník neposkytne potrebnú súčinnosť, sme oprávnení prerušiť práce. Okrem toho bude Zákazník povinný zná-

šať všetky súvisiace náklady navyše, vrátane straty času našich zamestnancov, ktorých nebude možné narýchlo využiť iným spôsobom ako aj akékoľvek náklady na dodatočný cestovný čas na základe platných cien uvedených v našom cenníku.

4. CENY A PLATOBNÉ PODMIENKY1. Ceny za poskytnutie služieb vychádzajú z cenníka za služby platného v čase uskutočnenia objednávky, ak nie je uvedené inak

v písomnej ponuke z našej strany.2. Služby budú vo všeobecnosti účtované v závislosti na skutočne strávenom čase podľa dohodnutých hodinových sadzieb plus

cestovné výdavky účtované na základe paušálnych poplatkov, alebo na základe reálne stráveného času (km a čas).3. Naše štandardné servisné hodiny sú pondelok – piatok od 8:30 do 16:30 . Mimo servisných hodín bude účtovaný 50% príplatok

k štandardnej cene. 100% príplatok k cene bude účtovaný za prácu poskytnutú v nedeľu a počas sviatkov a v čase od 20:00 do 7:00.

4. Náhradné diely budú účtované na základe cenníka platného v deň výmeny dielu jednotky. Vlastníckym právom k náhradným dielom disponujeme do úhrady faktúry v celej výške.

5. Faktúry budú vystavené po poskytnutí služieb alebo po vzájomnej písomnej dohode.6. V prípade, ak Zákazník zruší objednávku, dohodnuté stanovisko/jednotka bude nedostupná, Zákazníkovi bude účtovaný popla-

tok vo výške 50% hodnoty objednávky plus cestovné výdavky, minimálne však vo výške 250,00 Eur.7. Ak nebude určené inak, faktúry budú splatné bez zrážok ihneď po fakturácii.8. V ostatných prípadoch sa bude primerane aplikovať článok 4 (Ceny a platobné podmienky) našich všeobecných obchodných

podmienok pre predaj.

5. ZÁRUKA1. Zodpovedáme za starostlivé a profesionálne poskytovanie služieb. Všetky služby budú poskytované kvalifikovanými zamest-

nancami. 2. Zodpovednosť zo záruky preberáme iba v prípade, ak Zákazník uskutoční písomné oznámenie o viditeľných vadách v lehote

3 pracovných dní po vykonaní servisu a o akýchkoľvek iných vadách bezodkladne po ich počiatočnom zistení.3. V ostatných prípadoch sa bude primerane aplikovať článok 7 (Záruka) našich všeobecných obchodných podmienok pre predaj.

6. RÔZNE1. Všetok hardvér určený pre vzdialené monitorovanie funkčnosti (ERMC), ako sú modemy a dátové/SIM karty, bez ohľadu, či sú

nainštalované na/do alebo vmontované do dodaného tovaru alebo sú dodané Zákazníkovi osobitne, zostávajú vlastníctvom Predávajúceho po celý čas. Zákazník má právo tento hardvér používať počas doby, počas ktorej sú mu poskytované služby mo-nitorovania, pričom hardvér musí byť Predávajúceho vrátený ihneď po ukončení služby monitorovania.

2. Ak nie je uvedené inak, ustanovenia našich všeobecných obchodných podmienok pre predaj, najmä týkajúce sa lehoty dodania, výhrady vlastníctva, zodpovednosti, životného prostredia a licencií, osobných údajov, súdnej právomoci a rozhodného práva sa budú primerane vzťahovať aj na poskytovanie služieb.

DAIKIN AIRCONDITIONING CENTRAL EUROPE - SLOVAKIA s.r.o.

Galvaniho 15/C, SK - 821 04 Bratislava · Tel.: +421 (0) 2 57 10 32 11 · e-mail: [email protected] · www.daikin.sk

Daikin products are distributed by:

The present publication is drawn up by way of information only and does not constitute an offer binding upon Daikin Europe N.V. / Daikin Central Europe HandelsGmbH. Daikin Europe N.V. / Daikin Central Europe HandelsGmbH have compiled the content of this publication to the best of their knowledge. No express or implied warranty is given for the completeness, accuracy, reliability or fitness for particular purpose of its content and the products and services presented therein. Specifications are subject to change without prior notice. Daikin Europe N.V. / Daikin Central Europe HandelsGmbH explicitly rejects any liability for any direct or indirect damage, in the broadest sense, arising from or related to the use and/or interpretation of this publication. All content is copyrighted by Daikin Europe N.V.

Daikin Europe N.V participates in the Eurovent Certified Performance programme

for Fan Coil Units and Variable Refrigerant Flow systems. Daikin Applied Europe S.P.A participates in the Eurovent Certified Performance programme for Liquid

Chilling Packages, Hydronic Heat Pumps and Air Handling Units.

Check ongoing validity of certificate: www.eurovent-certification.com

DACE Applied Systems Pricelist 2021-2022 for SK | Version March 2021 We reserve the right for printing errors and model changes

ʯ Environmentally friendly R-32 refrigerant with a low GWP and low flammability classification

ʯ Comfort cooling and heating applications ʯ Two efficiency versions and three sound configurations ʯ Outstanding reliability: one or two independent refrigerant circuits with two or three compressors

ʯ Extended operating range, hot water up to 60°C ʯ Fully compatible with the Daikin on Site cloud-based platform including remote monitoring, system optimization and preventive maintenance

Multiscroll heat pump EWYT-B with low GWP R-32 Cooling 75 -610 | Heating 80-650 kW

Infinitechoice in heat pumps

Pri

celi

st 2

02

1-2

02

2 A

pp

lie

d S

yste