printed bySupported by an NSF EPSCoR Grant EPS-047262
REFERENCES1. Carls, J.C. et al, Time- resolved Raman spectroscopy from reacting optically levitated microdroplets, Appl. Optics, 29, 1990, pp. 2913-182. Cao, Y.C. et al, Raman Dye-Labeled Nanoparticle Probes for Proteins , J. Am. Chem. Soc., 125 (48), 14676 -14677, 20033. C. Xie, Y-qing Li, Confocal micro-Raman spectroscopy of single biological cells using optical trapping and shifted excitation techniques, J. Appl. Phys. ,
2003, 93(5), 2982-29864. Owen, C.A. et al , In vitro toxicology evaluation of pharmaceuticals using Raman micro-spectroscopy, J. Cell. Biochem., 2006, 99, 178-1865. Volpe, G. et al, Dynamics of a growing cell in an optical trap, Appl. Phys. Lett., 2006, 88, 231106-311086. Creely, S.M. et al, Raman imaging of neoplastic cells in suspension, Proc. SPIE, 2006, 6326: 63260U7. Shaevitz, J.W. , A practical Guide to Optical Trapping, web resource at www.princeton.edu/~shaevitz/links.html8. Neumann, K.C. et al, Characterization of Photodamage to Escherichia coli in optical traps, Biophys. J., 1999, 77(5), 2856-2863
Future development
In our nanotoxicity study, CRTS will be used to monitor the chemical and functional changes in nanoparticle-embedded living cells. Both stability of the trap, for around eight hours of successive spectra collection, and repeatability are required.1,2,3,4,5,6
For living cells, photodamage effects restrict the range of wavelengths to be used. We intend to employ a tunable 505 to 750nm (Coherent) beam for both tweezing and Raman excitation. The automatic fast laser beam steering will allow moving the beam focus in 3D to “chase” the cell that will be trapped and analyzed. For a photodamage initial evaluation, the life time of the trapped cells will be measured based on the fluorescence signal excited with the tunable laser 8 .Resonance Raman spectra for individual nanoparticles will be mapped spatially, near resonance, using the same tunable laser.A living cell embedded with nanoparticles will be monitored via CRTS over a series of different time points and distinguish the death or chemical changes in the cell.
Confocal Raman Tweezers for a Nanotoxicology ApplicationEmanuela Ene and James P. Wicksted
Department of Physics, Oklahoma State University
Raman spectra from trapped microobjects
Raman measurements from optically trapped dielectric and magnetic microparticles, under various visible laser excitation wavelengths, are being studied. Changes in the Raman spectra for trapped living cells embedded with nanoparticles will be investigated.
Imaging system
Laser
4X beamexpander
Confocal pinhole
Microscope objective piezo controlled
Dual axis AOD
Entranceslit
RamanspectrometerThe CRT system schematics
Our Confocal Raman Tweezing Setting
The laser trap’s image
16
The actual CRT system working with a green 514.5nm Ar+ ion laser
Fig. 1 Fig. 2
The CTRS schematics
Fig. 4
Fig. 3
OSLO Simulations for a Gaussian Beam
The tweezing profile in the image plane.The cover glass and the colloidal solution introduce aberrations(Fig.3);
trap image (tweezing focus) in the X-Y plane (Fig.4).
Microobjects optically manipulated
Fig. 6
Fig. 5
Cell “stuck” near a 0.8µm PMMA sphere with 6nm gold nanoparticles coating
SFM image of a cluster of 0.18μm PS “spheres” coated with 110nm SWCN.
Scanning range: 4.56μm
Diffraction rings of trapped objects. Sub-micrometer coated clusters were optically
manipulated near plant cells; both of the objects stayed in the trap for several hours.
PMMA = polymethylmethacrylate
Fig. 8
Slide with 1.5mm depression, filled with 5μm polystyrene (PS) spheres in water. Focus may move ≈ 440 μm from the cover glass.
Cover glass (n=1.525, t=150μm)
Aqueous solution of PS spheres (m=1.19)
Slide
Oil layer (n=1.515)Oil immersion objective
(NA=1.25)
Backward scattered Raman light
Incident laser beam
Δz≈440μm
Focusing objective and sample for calibration the CRT system
Fig. 9
The CRT spectrum collected from a single 5.0μm, polystyrene sphere ( Bangs Laboratoratories) continuously trapped for more than eight hours with a Meredith 632.8nm HeNe laser, 5mW in front of the objective. The total collection time was 1500s, with 2.0s per each 0.2cm-1 step.
Fig. 10
The Confocal Raman Tweezers Spectroscopy (CTRS) has the ability to provide precise characterization of a living cell without physical or chemical contact. The CRTS allows the analysis of single cells in wet samples, in contrast with the classical micro Raman spectroscopy that utilizes dried samples. In a confocal setting, the collected signal comes just from a minimum volume around the trapped-excited object.
The biological applications of nanoparticles, from imaging to drugs delivery, have created an increased interest in the past decades. Already in widespread use, superparamagnetic iron oxide nanoparticles associated with biological molecules are easily for manipulating and attractive for MRI contrast or targeted molecule delivery. Although used in biological and medical research, there is just little work done in investigating the effects of interactions between these magnetic particles and the living cells they are attached to.