Process Optimization Using On-line Continuous Zeta Potential Monitoring

Nano

Ana Morfesis, PhDMalvern Instruments, [email protected]

Water System Optimization ConferencePartnership for Safe Water - AWWAHershey, PA

October 30, 2015

Page 2: Process Optimization Using On-line Continuous Zeta Potential … · 2015. 11. 10. · Process Optimization Using On-line Continuous Zeta Potential Monitoring Nano Ana Morfesis, PhD

Coagulation Control in Water Treatment• Impurities in Wastewater are mostly Anionic

• Minerals• Organics• Domestic Sewage• Industrial Waste• Ecoli, Cryptosporidium and Giardia

• Cationic additives have been developed to neutralize chargeHigh Zeta Potential Low or Zero Zeta Potential

Unstable suspensionStable suspension

Page 3: Process Optimization Using On-line Continuous Zeta Potential … · 2015. 11. 10. · Process Optimization Using On-line Continuous Zeta Potential Monitoring Nano Ana Morfesis, PhD

Introduction – Impurities and Changes Raw Water Contains a Multitude of Impurities

Page 4: Process Optimization Using On-line Continuous Zeta Potential … · 2015. 11. 10. · Process Optimization Using On-line Continuous Zeta Potential Monitoring Nano Ana Morfesis, PhD

Introduction• Flocculation Chemistry is optimized by addition of chemicals that

neutralize the charge of particles in suspension.

• But….MORE CHEMICALS ≠ BETTER FLOC

Page 5: Process Optimization Using On-line Continuous Zeta Potential … · 2015. 11. 10. · Process Optimization Using On-line Continuous Zeta Potential Monitoring Nano Ana Morfesis, PhD

Introduction – The Problem with NOM Impurities

Organics vary with Source, Season and Runoff Events

*E.L. Sharp, NOM6 Sweden 2015 Conference

Page 6: Process Optimization Using On-line Continuous Zeta Potential … · 2015. 11. 10. · Process Optimization Using On-line Continuous Zeta Potential Monitoring Nano Ana Morfesis, PhD

Coagulation Control in Water TreatmentCurrent coagulation performance monitoring methods include

• Turbidity – no indication of charge• Filter loading - no indication of charge• Jar / Floc test – slow, no indication of charge• Streaming current – low sensitivity and not specific• Zeta potential

Jar Test

Floc Test

Page 7: Process Optimization Using On-line Continuous Zeta Potential … · 2015. 11. 10. · Process Optimization Using On-line Continuous Zeta Potential Monitoring Nano Ana Morfesis, PhD

Zeta Potential is NOT Streaming Current

Summary of differences in techniques

Streaming current Electrophoretic Light Scattering

Measures portion of particles that adsorb to cell walls

Measures all particles, organics and minerals directly

Calibration of output required

Absolute technique, no calibration required

The low concentration of particles in feed water leads to very low signal, therefore insensitive to small changes

Can measure at very low concentrations

Signal depends on the sample conductivity, which varies as the nature of the sample changes

Zeta potential is reported directly

Streaming Current Device

Page 8: Process Optimization Using On-line Continuous Zeta Potential … · 2015. 11. 10. · Process Optimization Using On-line Continuous Zeta Potential Monitoring Nano Ana Morfesis, PhD

Measuring Zeta Potential

Electrophoresis = Particle Velocity/Electric Field Strength

Page 9: Process Optimization Using On-line Continuous Zeta Potential … · 2015. 11. 10. · Process Optimization Using On-line Continuous Zeta Potential Monitoring Nano Ana Morfesis, PhD

Electrophoretic Light Scattering (ELS)Measured parameter is the frequency shift of the scattered light.

• Scattered light is frequency (Doppler) shifted• Frequency shift

f = 2 sin(/2)/ = the particle velocity = laser wavelength = scattering angle

• Frequency shifts determined by Fourier transformation and phase analysis light scattering

Page 10: Process Optimization Using On-line Continuous Zeta Potential … · 2015. 11. 10. · Process Optimization Using On-line Continuous Zeta Potential Monitoring Nano Ana Morfesis, PhD

Setting a Zeta Potential operating range

Under dosing Over dosing

-10 +3

Optimum

-10mV +3mV

Increase Coagulant Reduce Coagulant

Under Dose Over DoseOptimum Dose

-5mV

Page 11: Process Optimization Using On-line Continuous Zeta Potential … · 2015. 11. 10. · Process Optimization Using On-line Continuous Zeta Potential Monitoring Nano Ana Morfesis, PhD

Zeta optimization helps control Turbidity, NOM, DOC

Role of Zeta (ζ) Potential in the Optimization of Water Treatment FacilityOperations (Ind. Eng. Chem. Res. 2009, 48, 2305–2308)

Page 12: Process Optimization Using On-line Continuous Zeta Potential … · 2015. 11. 10. · Process Optimization Using On-line Continuous Zeta Potential Monitoring Nano Ana Morfesis, PhD

New Mexico Facility – FeCl3

-20

-15

-10

-5

0

5

10

0

5

10

15

20

25

0 20 40 60 80 100

Zeta

Pot

entia

l, m

v

pH, T

urbi

dity

, UVA

FeCl3 Dose, mg/L

Zeta Tests at Reduced pH

pH

Turbidity

UV254

Zeta Potential

Page 13: Process Optimization Using On-line Continuous Zeta Potential … · 2015. 11. 10. · Process Optimization Using On-line Continuous Zeta Potential Monitoring Nano Ana Morfesis, PhD

On-line Zetasizer WT

Page 14: Process Optimization Using On-line Continuous Zeta Potential … · 2015. 11. 10. · Process Optimization Using On-line Continuous Zeta Potential Monitoring Nano Ana Morfesis, PhD

On-Line Zeta Measurements

• Based on Zetasizer Nano platform• Automated sampling and industrial controls• Malvern Link II - software for automation control

and integration into plant SCADA

• Coagulation is a critical step that effects the rest of the process• Incoming water can change rapidly • Plant impacts in less than an hour• Rapid detection of treatment events• Precise dosing = chemical optimization• Manpower optimization• Integration into plant control system• Enabling automatic dose control (future steps)

Why on-line?

Zetasizer WT

Page 15: Process Optimization Using On-line Continuous Zeta Potential … · 2015. 11. 10. · Process Optimization Using On-line Continuous Zeta Potential Monitoring Nano Ana Morfesis, PhD

Evaluating coagulant impact ACH & Polymer

160 MGD plant in Northern Utah

Filtered Turbidity

Zeta

Flow

ACH

Polymer

Zeta Potential [mV]

Page 16: Process Optimization Using On-line Continuous Zeta Potential … · 2015. 11. 10. · Process Optimization Using On-line Continuous Zeta Potential Monitoring Nano Ana Morfesis, PhD

Zeta potential and Ferric Sulphate

Data courtesy of Severn Trent Water

Ferric

Zp

Page 17: Process Optimization Using On-line Continuous Zeta Potential … · 2015. 11. 10. · Process Optimization Using On-line Continuous Zeta Potential Monitoring Nano Ana Morfesis, PhD

Responding to changing conditions…

Data courtesy of Severn Trent Water

Organics

Zp

Turbidity

Ferric

Page 18: Process Optimization Using On-line Continuous Zeta Potential … · 2015. 11. 10. · Process Optimization Using On-line Continuous Zeta Potential Monitoring Nano Ana Morfesis, PhD

Detecting a process upset…

Data courtesy of Tacoma Water Green River plant

Filtered Turbidity

Zeta

Page 19: Process Optimization Using On-line Continuous Zeta Potential … · 2015. 11. 10. · Process Optimization Using On-line Continuous Zeta Potential Monitoring Nano Ana Morfesis, PhD

Early Access unit at Wemlinger plant, Aurora CO

• 80 MGD Direct Filtration Plant using lab Zetasizer since 2010• Plant relies on Zeta potential for dosing decisions since 2011

-3mV - +3mV optimal rangeLab Zeta measured once a shift

• Zetasizer WT system installed in 2012• On-line system - > 400 measurements per day• On-line results & Lab Zeta results match• Data exchange with plant control DeltaV system

via Modbus TCP/IP

- Members of the Partnership for Safe Water

- Awarded Excellence in Water Treatment Award, Partnership for Safe Water 2008

- Average annual Combined Filter Effluent Turbidity 0.023 NTU.

Page 20: Process Optimization Using On-line Continuous Zeta Potential … · 2015. 11. 10. · Process Optimization Using On-line Continuous Zeta Potential Monitoring Nano Ana Morfesis, PhD

Direct Filtration Plant

Page 21: Process Optimization Using On-line Continuous Zeta Potential … · 2015. 11. 10. · Process Optimization Using On-line Continuous Zeta Potential Monitoring Nano Ana Morfesis, PhD

Lab Zeta vs. On-line Zeta

-10.000

-8.000

-6.000

-4.000

-2.000

0.000

2.000

4.000

6.000

8.000

10.000

1/31/2013

2/10/2013

2/20/2013

3/2/2013

3/12/2013

3/22/2013

4/1/2013

4/11/2013

4/21/2013

5/1/2013

On-line Zeta

Lab Zeta

Wemlinger Water Purification Facility

Page 22: Process Optimization Using On-line Continuous Zeta Potential … · 2015. 11. 10. · Process Optimization Using On-line Continuous Zeta Potential Monitoring Nano Ana Morfesis, PhD

Lab Zeta vs. On-line Zeta

-8.000

-6.000

-4.000

-2.000

0.000

2.000

4.000

6.000

8.000

10.000

5/26/2013

6/5/2013

6/15/2013

6/25/2013

7/5/2013

7/15/2013

7/25/2013

8/4/2013

On-line Zeta

Lab Zeta

Wemlinger Water Purification Facility

Page 23: Process Optimization Using On-line Continuous Zeta Potential … · 2015. 11. 10. · Process Optimization Using On-line Continuous Zeta Potential Monitoring Nano Ana Morfesis, PhD

On-line dataZeta potential data used to stabilize the plant after PLC failure

Alum = 4.10 mg/l and Cationic polymer = 3.05 mg/l.

Alum = 3.65 mg/l and Cationic polymer = 2.75 mg/l

Page 24: Process Optimization Using On-line Continuous Zeta Potential … · 2015. 11. 10. · Process Optimization Using On-line Continuous Zeta Potential Monitoring Nano Ana Morfesis, PhD

On-line data

Zeta potential data used to stabilize the plant after PLC failure

~12 hours

Page 25: Process Optimization Using On-line Continuous Zeta Potential … · 2015. 11. 10. · Process Optimization Using On-line Continuous Zeta Potential Monitoring Nano Ana Morfesis, PhD

Observed negative effect of Rapid mixing

~17% reduction in dosing with mixer off!

Stable dose a few days after the event:Alum = 3.40 mg/l and Cationic polymer = 2.55 mg/l

Page 26: Process Optimization Using On-line Continuous Zeta Potential … · 2015. 11. 10. · Process Optimization Using On-line Continuous Zeta Potential Monitoring Nano Ana Morfesis, PhD

Zeta vs. SCM

• On-line Zeta matches Lab Zeta• Streaming Current Monitor not showing shift to negative charge.

Page 27: Process Optimization Using On-line Continuous Zeta Potential … · 2015. 11. 10. · Process Optimization Using On-line Continuous Zeta Potential Monitoring Nano Ana Morfesis, PhD

Aurora - Wemlinger Results› Addressing technology gap for coagulation control

› Enables unattended operation, automation of dosing control and man power optimization – future proofing.

› Significant savings in chemicals and less sludge

› Wemlinger plant ~20% cost savings by switching to zeta.› Improving plant stability, preventing breakthroughs and

extending filter operating times

2010 2011 2012 2013

Alum Costs$ 69,576.64 $55,870.98 $56,879.70 $34,466.31

PEC Cost$ 214,912.09 $72,709.90 $68,071.11 $56,685.22

Coag. Summary$ 284,488.73 $128,580.88 $124,950.81 $91,151.53

Cost per Million$32.55 $22.81 $18.43 $20.70*

MG Delivered8739.44 5636.47 6780.99 4402.88

*2013 numbers impacted by flooding

Wemlinger WPF

Page 28: Process Optimization Using On-line Continuous Zeta Potential … · 2015. 11. 10. · Process Optimization Using On-line Continuous Zeta Potential Monitoring Nano Ana Morfesis, PhD

Published Results

Page 29: Process Optimization Using On-line Continuous Zeta Potential … · 2015. 11. 10. · Process Optimization Using On-line Continuous Zeta Potential Monitoring Nano Ana Morfesis, PhD

Wemlinger Operators Say:› “Zeta potential provides a measurable and reliable value

indicating when a production issue occurs”

› “It provides better sensitivity and is a sharper indicator that the process has changed.”

› “This information helps our operators make informed decisions”

› “The on-line zeta measurement is a proactive tool for preventing treatment problems and keeping water processing plants operating smoothly.”

Page 30: Process Optimization Using On-line Continuous Zeta Potential … · 2015. 11. 10. · Process Optimization Using On-line Continuous Zeta Potential Monitoring Nano Ana Morfesis, PhD

SummaryZeta potential measurements, 1st Principals, direct measurement

Not Calibrated Charge monitoring / zeta potential,

allows for precise control of coagulant dosing

Process; Conventional, Direct Filtration, HybridSize; 40 MGD – 160 MGDChemistry; Alum, ACH, Ferric Sulfate and Chloride, cationic polymers

• Significant cost savings were obtained

• Plant stability was often considered even more important.

“Severn Trent Water have been using the Malvern Zetasizer technology for over

5 years and currently use zeta potential to optimize the coagulant dose at several

of our water treatment works. I am a firm believer in this technology and have

welcomed the opportunity to work with Malvern Instruments and to support this

transition into an online arena - which has the potential to revolutionize

coagulation control within the Water Industry in the future.”

Emma Sharp, Water Treatment and Quality Lead, Severn Trent Water, UK