76
Manufacturing ∙ Project Design ∙ Sales ∙ Commissioning ∙ Servicing ∙ Repairs Waste water pumping systems Packaged pumping stations Macerators and macerating toilets Rainwater harvesting systems Floor mounted pumping stations Fat, oil and grease separator systems Product Catalogue 2008–2009

Product Catalogue - ESIcms.esi.info/Media/documents/Edinc_Catalog_ML.pdf · • Optimum performance of prthe pump system; • Improved environmental conditions. Our service agreements

  • Upload
    others

  • View
    10

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Product Catalogue - ESIcms.esi.info/Media/documents/Edinc_Catalog_ML.pdf · • Optimum performance of prthe pump system; • Improved environmental conditions. Our service agreements

Manufacturing ∙ Project Design ∙ Sales ∙ Commissioning ∙ Servicing ∙ Repairs

Waste water pumping systemsPackaged pumping stations Macerators and macerating toilets

Rainwater harvesting systemsFloor mounted pumping stations Fat, oil and grease separator systems

Product Catalogue2008–2009

Page 2: Product Catalogue - ESIcms.esi.info/Media/documents/Edinc_Catalog_ML.pdf · • Optimum performance of prthe pump system; • Improved environmental conditions. Our service agreements

PowerFlush ...........................................38

MaxiFlush ..............................................40

MaestroSanisplit ...................................42

Remota .................................................44

SuperFlush ............................................46

AutoFlushXL ..........................................16

AutoFlushVOX ....................................... 18

AutoFlushCSL .......................................20

AutoFlushTwin .......................................22

AutoFlushHT .........................................24

AutoFlushHTTwin ..................................26

AquaFlush .............................................28

HydroFlush ............................................30

ShowerFlush .........................................32

BlueMax ................................................34

SumpFlush ............................................36

MagnaPro (Macerator model) .................6

MagnaPro (Vortex model) .......................8

MagnaGrand .........................................10

MagnaStandard .................................... 12

MagnaCutter ......................................... 14

Goliath110.....................................................48

Atlas110Twin ................................................50

Atlas1702 ......................................................52

PowerMaster .........................................54

PowerMasterTwin ..................................56

WaterGuard .................................................58

Grease Guardian ...................................60

BioDose ........................................................62

EcoTrap .........................................................64

ProTrap .................................................65

Enquiry specification sheet.......................69

Account opening form ...............................70

Flows and measures ..................................71

Conditions of sale .......................................75

High level alarms .........................................66

Floats .............................................................66

Float brackets ..............................................67

Counter weights ..........................................67

MDPE/HDPE pipe work ............................67

Compression adaptors ..............................67

BioFax ...........................................................67

Control panels .............................................68

Control panel (accessories) ......................68

Kiosks ...........................................................68

Access covers .............................................68

Lifting chains ...............................................68

Introduction .............................................3

After Sales ..............................................4

Head Office:

Unit 8, Heron Business Park,

Eastman Way,

Hemel Hempstead,

Hertfordshire HP2 7FW

Tel 01442 211554

Fax 01442 211553

[email protected]

www.edincare.com

Rainwater harvesting systems

Packaged pumping stations

Floor mounted pumping stations

Fat, oil and grease

separator systems

Macerators & macerating toilets

Waste water pumping systems

Accessories

PRODUCT SELECTION

• Completethe‘EnquirySpecification

Sheet’ located on page 69 and fax

to 01442 211553.

• Visitwww.edincare.comand

completethe‘OnlineSpecification

Form’.

• Telephoneuson01442211554and

discuss your requirements with one

of our experienced sales engineers.

ORDER yOUR 2008 PRICE LIST

Contact us on

01442 211554 to

request your 2008

price list.

ORDERINg

For ordering simply call, fax or email:

Tel: 01442 211554

Fax: 01442 211553

Email: [email protected]

Page 3: Product Catalogue - ESIcms.esi.info/Media/documents/Edinc_Catalog_ML.pdf · • Optimum performance of prthe pump system; • Improved environmental conditions. Our service agreements

We are proud to present our updated product catalogue for 2008/09. There is

information on our complete product range including a number of new and improved

products, such as the Grease Guardian™ and MagnaPro™ range to name a few.

We trust that you will find this catalogue informative and easy to use, you will find

product information and technical specifications on each of our products as well

as summarised installation guidelines. In addition to our main products we have

included a wide range of accessories, enabling you to tailor the products to meet

your specific requirements.

We operate nationwide and in Europe on a next working day delivery for most of

our product range, offering our customers the flexibility of ordering products at

the last minute.

The past year has seen us committed in our policy of developing our

Service Department here at Edincare, with additional engineers both on

the road and in-house. We aim to provide a rapid response to emergency

call outs, in addition to offering a comprehensive scheme for planned

maintenance and fulfil 24-hour turnaround on the majority of services

carried out in our workshop.

We are pleased to announce that we have recently moved our

headquarters into larger premises allowing us to centralise our offices,

warehouse and production area under one roof. This new facility will

enable us to expand our stock level along with providing offices for

our expanding sales and service staff.

If you require further advice or assistance concerning our product

range, or any pumped drainage issues, our experienced Sales

Team are ready to offer their advice. We are also happy to arrange

free site surveys for customers that require on-site assistance.

PowerFlush ...........................................38

MaxiFlush ..............................................40

MaestroSanisplit ...................................42

Remota .................................................44

SuperFlush ............................................46

EDINCARE PUMPED DRAINAGE SYSTEMS 3

INTRODUCTION

Why not visit our website at www.edincare.com

Our website contains information

on our complete product range

with the ability to download,

installation & operating guidelines,

product sheets and technical

drawings.

Furthermore you have the ability to

submit your pumping requirements

using our ‘Online Specification

Form’. This features a step-by-step

guide to all relevant information

required to obtain a full quotation.

We aim to respond within 24 hours

with your full product selection

complete with costings.

Our policy is one of continuous product improvement, we reserve the right to change speci�cations and prices without prior notice. All information is given in good faith. No responsibility can be accepted for errors, omissions or incorrect assumptions. © Copyright 2007 Omni Pump International Ltd t/a Edincare Pumped Drainage Systems. All rights reserved. CM/IOGTD/MAGNAPRO2000SINGLE/1107

PLEASE NOTE THAT THIS DOCUMENT MUST BE READ IN CONJUNCTION WITH THE INSTALLATION & OPERATING GUIDELINES.

DRAWING NOT TO SCALE.

DATE

CUSTOMER NAME

PROJECT NAME

PROJECT ADDRESS

PRODUCT NAME

DRAWING VERSION

FABRICATION SPECIFICATIONS

ITEM INDEXDEPTH (mm)

DIAMETER (mm)

CLOCK FACE

POSITION

Tank depth A

Tank diameter B

Inlet C1

Inlet C2

Inlet C3

Inlet C4

Discharge D 12

Slab (inc. cover) E

Cable Duct

Vent

ACCESS COVER (CLEAR OPENING)

LENGTH (mm) WIDTH (mm) TYPE

DRAWN BY CHECKED BY

COMMENTS:

TECHNICAL SPECIFICATIONS

Power Supply

Rated Current

Motor Rating

Frequency

Revolutions per Minute

Max. Vertical Output

Max. Horizontal Output

Max. Flow Rate

Max. Liquid Temperature

Discharge Size

Cable Length

Weight

Colour

MagnaPro2000 – Technical Drawing

CLOCK FACE POSITIONS

DISCHARGE

12o’clock

1

2

3

4

56

7

8

9

10

11

View looking down on the tank.Treat this diagram like a clockface.DISCHARGE is set at 12 o’clock.

Indicate the relative positions for INLETS, CABLE DUCT and VENT (if required).

Edincare Pumped Drainage Systems

Unit 10, Avebury Court, Mark Road,

Hemel Hempstead,

Herts HP2 7TA

Tel: 01442 211554,

Fax: 01442 211553,

Email: [email protected],

Web: www.edincare.com

KIOSK (SINGLE DOOR)

LENGTH (mm) WIDTH (mm) HEIGHT (mm)

SHOULD YOU REQUIRE ANY TECHNICAL ASSISTANCE PLEASE CONTACT OUR HELPDESK ON 01442 211554 OR EMAIL [email protected]

ACCESS COVER

GUIDE RAIL

LIFTING CHAIN

PUMP

HARDCORE BASE

HARDCORE BASE

CABLE DUCT(MIN. 110mm)

INCOMING POWERSUPPLY DUCT(MIN. 110mm)

CONCRETE BASE & BACKFILL

FLOAT SWITCHES TANKIMPACT RESISTANTPOLYETHYLENE

RISING MAIN

COMPRESSION FITTING

VENT DUCT TO BE VENTED TO ATMOSPHERE(NO DURGO VALVE TO BE USED)

CONCRETE SLAB

CONCRETE SLAB

KIOSK

UNISTRUT CROSSBEAM BASE

BEACON (OPTIONAL EXTRA)

NON-RETURN VALVE

GATE VALVE

A B C

D E

F

G

E

A

B

DC

GATE VALVE

COMPRESSION FITTING

PEDESTAL

GUIDE RAIL

EYE BOLT FORLIFTING CHAIN

PUMP

UNISTRUTCROSSBEAMBASE

MOULDED FEET(HIDDEN)

RUBBER INLET SEAL(INLETS CUT TO YOURREQUIREMENTS)

UNISTRUT TOPBRACKET BAR(IF APPLICABLE)

FLOAT BRACKETS

RISING MAINSIDE ELEVATIONS

PLAN VIEW

Page 4: Product Catalogue - ESIcms.esi.info/Media/documents/Edinc_Catalog_ML.pdf · • Optimum performance of prthe pump system; • Improved environmental conditions. Our service agreements

AFTER SALES

Service agreements are offered to all customers who

require the benefits of planned maintenance.

Our service agreements are available at competitive

prices, and we will undertake to service equipment

at regular intervals, regardless of type, make or age,

subject to inspection and contract. We will supply

you with a full service report on the work undertaken

and the condition of the pump(s) and other related

equipment each time our engineers attend site.

You can see substantial benefits through:

• Greaterlifeexpectancyforequipment;

• Areductioninrunningcostsincludingenergyand

maintenance;

• Reducedriskofbreakdownwithitsresultant

problemsandinconveniences;

• Optimumperformanceofthepumpsystem;

• Improvedenvironmentalconditions.

Our service agreements consist of the following:

• Scheduledservicevisitsatyourconvenience;

• Reducedhourlychargesforunscheduledcallouts;

• Fullytrainedserviceengineers.

• Prioritycall-outs.

A commissioning service

is offered on all of our

products ensuring the

product functions

in accordance with

our Installation and

Operating Guidelines.

On completion of the

commissioning visit a

certificate is issued.

SERvICE AgREEMENTS

COMMISSIONINg EMERgENCy CALL-OUTS

We offer an emergency call-out service in the event of any

problem with a pump system. Our service department

will endeavour to respond within 24 hours from the initial

contact to provide an engineer to site. Almost all repairs are

completed on site or if necessary within our workshop using

only genuine manufacturer’s spare parts.

We offer planned servicing, commissioning, emergency repairs, refurbishments and

concrete ring installations on our complete product range, enabling us to provide our

customers the highest level of customer service and support.

Commissioning Certi� cate

//

For and on behalf of Omni Pump International Limited, t/a

Edincare Pumped Drainage Systems

Edincare Pumped Drainage Systems

Unit 10, Avebury Court, Mark Road, Hemel Hempstead, Herts. HP2 7TA

Tel: 01442 211554, Fax: 01442 211553, Email: [email protected], Web: www.edincare.com

This document certifi es that the following product(s):

PRODUCT NAME

have been tested in accordance with Edincare Pumped Drainage Systems

Operation Guidelines at the following site:

SITE NAME

SITE ADDRESS

POST CODE

On the following date:AUTHORISED SIGNATURE

EDINCARE PUMPED DRAINAGE SYSTEMS4

EDINCARE/SA/0607/MAIN

Page 3 of 3.

WORK SCHEDULE

Contract Ref. (Offi ce Use Only): Site address (if different from above):

Site contact:

Telephone (Home):Mobile:

Location of installation:

(Back Garden near shed. Please provide details of installation e.g. internal or

external, brief description of where on the above property the unit is installed.)

Preferred service month(s):Jan

Feb Mar

Apr May

Jun

Jul Aug

Sep Oct

Nov Dec‘All emergency callout visits will be charged at our ‘Emergency Call

Out – Service Agreement’ tariff. For hourly rates and full terms &

conditions please refer to our ‘Service Request Form’.

EMERGENCY CALL OUT

EQUIPMENT SCHEDULE

SCHEDULE OF WORK TO BE PERFORMED AT EACH VISIT

Condition on ArrivalPump/s RunningHigh Level AlarmPump Tripped / OverloadCondition of Pump (Visual Inspection)

Clear & FreeBlocked Condition of Pump (Mechanical Inspection)

ImpellerBottom PlateCutters

Condition of OilManual Impeller turnBearing Side movementControl PanelOverload SettingOperation of Float Switches

Bulbs / FusesAlarm Mute FunctionRunning CurrentGeneralPedestal / Guide RailDebris

Float Switches / Level Controls

Valves / PipesAccess CoverChamber/TankLifting Chains

Name:Address:

Post Code:

Edincare Pumped Drainage Systems

Unit 10, Avebury Court, Mark Road,

Hemel Hempstead,Herts HP2 7TA Tel: 01442 211554

Fax: 01442 211553Email: [email protected]

Web: www.edincare.com

Product Name:Pump TypeQuantity

Power SupplySerial No:Notes:

Product Name:Pump TypeQuantity

Power SupplySerial No:Notes:

Product Name:Pump TypeQuantity

Power SupplySerial No:Notes:

Product Name:Pump TypeQuantity

Power SupplySerial No:Notes:

Product Name:Pump TypeQuantity

Power SupplySerial No:Notes:

Our policy is one of continuous product improvement, we reserve the right to change specifi cations and prices without notice. All information is given in good faith. No responsibility can be accepted for errors,

omissions or incorrect assumptions. © Copyright 2007 Omni Pump International Limited t/a Edincare Pumped Drainage Systems. All rights reserved.

Telephone (Work):Fax:

Email:

EDINCARE/SA/0607/MAIN

Page 2 of 3.

(14) Transfer of Contract The Client shall not transfer this Agreement, or any part of it, to any third party without the Company’s written authorization which, subject to administration fees, shall not be unreasonably withheld. Notwithstanding the transfer of this Agreement, the Client will remain liable under this Agreement but this liability shall cease within six months of the transfer provided that the Client is not in breach of the terms of this Agreement and that at the expiration of the said six months there are no outstanding breaches of the Clients obligations under the terms of this Agreement and the Company is satis� ed that the party to whom this Agreement is to be transferred has agreed in writing with the Company (to the Company’s satisfaction) to be bound

by the terms of this Agreement and is likely to comply with such terms.

(15) Contract Modifi cation The terms and conditions of this Agreement supersede any terms

or conditions proposed by the Client and may not be varied except with the written consent of a Director of the Company. In the case of a written consent by a Director of the Company to a variation or deviation from one or more of the terms and conditions of this Agreement, the other terms and conditions shall remain fully operative.

(16) Overseas Purchases This Agreement is not available where the product is sold or installed

outside of mainland UK.

SERVICE AGREEMENT FORUNITED KINGDOM INSTALLATIONS

On Behalf of The Client: Customer name (Print):

Customer Signature:

Position:

Date:

I, the above, acknowledge receipt of this Service agreement. I have read and understood its contents and agree to abide by the terms and

conditions therein.

On Behalf of The Company:Company name: EDINCARE PUMPED DRAINAGE SYSTEMSDirectors Signature:

Date:

Edincare Pumped Drainage SystemsUnit 10, Avebury Court, Mark Road,Hemel Hempstead,Herts HP2 7TA

Tel: 01442 211554Fax: 01442 211553Email: [email protected]: www.edincare.comOur policy is one of continuous product improvement, we reserve the right to change specifi cations and prices without notice. All information is given in good faith. No responsibility can be accepted for errors,

omissions or incorrect assumptions. © Copyright 2007 Omni Pump International Limited t/a Edincare Pumped Drainage Systems. All rights reserved.

EDINCARE/SA/0607/MAIN

Page 1 of 3.

Contract Ref. (Offi ce Use Only):

An agreement made on (Date):

between (in this agreement referred to as “the Client”):

Name:

Address:

Post Code:

and (in this agreement referred to as “the Company”):

Edincare Pumped Drainage Systems

Unit 10, Avebury Court

Mark Road

Hemel Hempstead

HertsHP2 7TA

of which it has been agreed that:

(1) As from the date of signing this agreement, the Company will

undertake to service the equipment as recorded under ‘Equipment

Schedule’ at the location recorded under ‘Work Schedule’.

(2) Service Intervals

The service(s) will be carried out at intervals of

1 / 3 / 6 / 12 Month(s).

The intervals may be altered by agreement between the parties and

recorded under ‘Work Schedule’.

(3) Service Charge

+ VAT per site visit.

The amount above will be paid by the Client to the Company in

accordance with Clause 9 of this agreement until further notice as

provide for in Clause 8 of this agreement.

(4) Site Access

The Client is responsible for ensuring immediate, safe and

uninterrupted access to the pump equipment. The Client will incur

additional charges if there has been any interference with the

equipment, interrupts the engineer, fails to provide the required

access or unreasonably delays the engineer’s work.

(5) Cancelling Service Visits

The Client must advise the Company of a date change or

cancellation no less than 72 hours before the Service Visit. The full

Service Visit charge will be applied for non compliance.

(6) Insurance

The Company excludes all liability for any consequential or indirect

loss suffered by the Client whether this loss arises from breach of

a duty in contract or tort or in any other way (including loss arising

from the Company’s negligence). Non exhaustive illustrations

of consequential or indirect loss include: Loss of pro� t; Loss of

contracts; Damage to the property of the Client or anyone else;

Personal injury to the Client or anyone else (when the injury is not

caused by the Company’s negligence).

(7) Defects

This Agreement does not apply to defects caused by incorrect � tting

or erection, usage of third party equipment, abnormal conditions

of working, accident, misuse, neglect or, interference or attempted

repairs or servicing by a third party.

Repair works will not be undertaken prior to the Company receiving

an of� cial instruction from the Client to proceed at an agreed price.

(8) Term

This Agreement shall operate on a continual basis unless terminated

by either party giving notice in writing one month prior to the date of

cessation.

(9) Payment

The Annual Service charge is to be paid to the Company in full by

the 1st of January of the relevant year during the continuance of the

Term. The Company reserves the right to charge interest on overdue

amounts at 3% above the Base Rate of Barclays Bank PLC from the

time being in force for the period from date payment is due until the

actual date of payment. The Company reserves the right to suspend

all obligations including service calls under the Agreement if the

Annual Fee (or any other invoiced amount payable pursuant to this

Agreement) is due, owing and remaining unpaid.

Where accounts have been approved for credit, payment terms are

30 days from date of invoice. Proforma invoices requiring payment in

advance of any works will be issued to all non account clients.

(10) Replacement Components

This Service Agreement does not include for free replacement

or repair of components. However, wherever possible if deemed

necessary, any essential service or repair will be effected during a

Service Visit and invoiced accordingly. Such decision to be at the

sole discretion of the Company.

Major works will not be undertaken prior to the Company receiving

an of� cial instruction from the Client to proceed at an agreed price.

(11) Price Review

The Company reserves the right to increase the fee payable under

this Agreement by the same percentage as the increase in the Retail

Price Index, as published by the relevant Government Department

and/or revise the fee payable under this Agreement, such increases/

revisions to be noti� ed to the Client for approval 30 days prior to the

anniversary of the commencement date of the Agreement.

(12) Site Report

A report will be issued relating to the: Operation of the equipment;

Condition of the Equipment; Client responsibilities. Any remedial

works required and associated charges will be advised.

(13) Removal/Suspension of Service

Without prejudice to any other rights or remedies of the Company:

If a receiver or manager is appointed over any of the assets

or undertakings of the Client; or a petition is presented for the

appointment of an administrator or a winding up petition is

presented against the Client; or the Client goes into voluntary

liquidation or calls a meeting of or makes any arrangement or

composition with its creditors; or the Client commits any act of

bankruptcy or becomes unable to meet its debts within the meaning

of Section 123 of the Insolvency Act 1986; or there is any default

by the Client in making payment according to this Agreement, the

Company shall be entitled after having sent written notice requesting

payment within seven days to the Client (Which shall be deemed to

have been validly given if sent with a Certi� cate of Posting to the last

address known to the Company) – to suspend all services until all

monies have been duly received by the Company.

(Tick appropriate box)

SERVICE AGREEMENT FOR

UNITED KINGDOM INSTALLATIONS

DB No. (Offi ce Use Only):

Page 5: Product Catalogue - ESIcms.esi.info/Media/documents/Edinc_Catalog_ML.pdf · • Optimum performance of prthe pump system; • Improved environmental conditions. Our service agreements

AFTER SALES

To find out more about our after-sales

services please contact our Service

Team on 01442 211554 or visit our

website at www.edincare.com

REFURBISHMENTS

With our extensive knowledge of pumping systems we are able to offer

the complete service when it comes to pump station refurbishments.

Customers can simply assign the responsibility for the refurbishment to

our service department knowing that our team of experienced engineers

will not only complete the upgrade on time but where possible offer a

rental system to minimise any inconvenience.

CONCRETE RINg INSTALLATIONS

In addition to our packaged pumping stations, we offer pump sets

for installation within concrete rings. We offer both the supply and

installation of this type of application.

RENTALS

We offer a wide range of systems for both short and long term rental.

Simply contact us for further information on this service.

EDINCARE PUMPED DRAINAGE SYSTEMS 5

HEALTH AND SAFETy

With the ever-increasing demand put on our

customers to stay abreast of their health and

safety commitments, here at Edincare we

have worked hard to compile all our health

and safety documentation into one easy to

access area. Simply visit our website at

www.edincare.com, and click on downloads,

you will be asked to register after which you

will have full access to this area.

The following is available for download:

• Health&SafetyPolicy

• EnvironmentalPolicy

• TrainingDocumentation

• Method&RiskAssessments

• Insurance,Health&Safetycertificate

Page 6: Product Catalogue - ESIcms.esi.info/Media/documents/Edinc_Catalog_ML.pdf · • Optimum performance of prthe pump system; • Improved environmental conditions. Our service agreements

1YEAR

One-year GuaranteeTerms and conditions apply.

ServiCe aGreementSIt is essential this product undergoes routine servicing. Please contact our service dept. for further information.

PACKAGED PUMPING STATIONS6

MAGNAPRO™ macerator model

ACCESSORIES

200–360 litre storage capacity

(depending on inlet level).

540–900 litre storage capacity

(depending on inlet level).

Magna900Pro

Magna360Pro

1300–2000 litre storage capacity

(depending on inlet level).

Magna2000Pro

The system is suitable for installing either at the

initial building stage or retro fitting to existing

buildings and can accept waste from a basement,

entire house/s or similar.

The system consists of a polyethylene tank,

locking access cover, internal pipework and

fittings, control panel, float switches with one or

two built in macerating submersible pumps.

The MagnaPro is easy to install as inlets can be

positioned to your requirements (inlet information

to be supplied at time of order).

The MagnaPro is a fully automatic

pumping station specifically designed

for pumping both foul and storm water

when gravity drainage is not possible or

economical to install.

For further information,

call 01442 211554 to

order your free

Magna brochure

Magna2000Pro

Magna900Pro

Magna360Pro

Recessed cover Additional inlets Kiosk

Telemetric system

MDPE / HDPE

AL

AR

M

Page 7: Product Catalogue - ESIcms.esi.info/Media/documents/Edinc_Catalog_ML.pdf · • Optimum performance of prthe pump system; • Improved environmental conditions. Our service agreements

Competitive range of packaged pumping stations

SPECIFICATIONSINSTALLATION gUIDELINES

7PACKAGED PUMPING STATIONS

Tel 01442 211554

Fax 01442 211553

[email protected]

www.edincare.com

For prices and additional information please

contact Sales on 01442 211554

It is important to note that these

instructions are for guidance only.

Please refer to the full Installation

and Operating Guidelines when

specifying / installing the product.

Siting the product

The MagnaPro is designed to be

installed below ground level and

so the prevailing ground conditions

must be considered prior to locating

the unit. Where possible, installation

of a pumping station in a roadway

should be avoided due to the need for

periodic maintenance of the pump(s)

contained therein. If the location is

adjacent to a roadway, the installation

method should take into account the

imposed loads likely to be transmitted

to the tank by traffic etc.

The MagnaPro should be positioned in

a sump with sufficient dimensions to

allow for a concrete surround.

Inlet connection

The MagnaPro comes complete with

a 110mm rubber connector located

on the side of the tank that will accept

110mm uPVC soil waste pipe. The

waste pipe needs to be run with

sufficient gradient to allow the waste

to gravity drain into the unit and should

be pushed firmly into the 110mm

rubber connector so as to form a

watertight seal around the incoming

pipe.

NOTE Inlets can be positioned to your

requirements but must be specified at

time of order.

Discharge connection

The connection of the discharge line is

via the supplied compression adaptor.

This connector is designed to accept

black MDPE / HDPE pipework of

appropriate outer diameter.

Electrical connection

A qualified person in accordance with

the Institute Of Electrical Engineers

Regulations should connect the

unit to the appropriate mains supply

taking into account all the electrical

information provided.

IMPORTANT – All pump systems

must be used with an appropriate

motor rated protection device.

Maintenance

We recommend that the unit be

inspected every three months. The

inside of the MagnaPro should

be inspected to ensure the floats

are clean and free of any build up

of materials that may inhibit the

operation of the float switch. Also the

moving parts of the pump(s) should

be checked to ensure that they are

moving freely. Hose down the interior

of the tank if necessary to remove

any build up of solid materials and

the bottom of the tank should be

checked to make sure there is no

debris or materials that could enter

the pump(s) and cause irreparable

damage.

In addition we recommend that a

service agreement be taken out with

a technically qualified company.

Health & safety

As with all site work, the danger of

working with water and electricity

can pose a severe threat to

health if obvious and fundamental

precautions are not taken. Therefore

if you are in any doubt regarding the

installation, please contact us.

All site work must be undertaken by

qualified personnel only.

These notes are for guidance only

and it is for the installer to ensure

the installation is in accordance

with all structural and regulatory

requirements.

Model Diameter Height

Magna360Pro 850mm 1250mm

Magna900Pro 1100mm 1500mm

Magna2000Pro 1350mm 2000mm

Also available in Three Phase (400V AC) and both

single/twin pump setups. Please call for technical

specifications.

Model 360Pro 900Pro 2000Pro

Power Supply 230V AC 230V AC 230V AC

Rated Current 5.1A 5.1A 5.1A

Motor Rating 750W 750W 750W

Frequency 50Hz 50Hz 50Hz

Revolutions per Minute

2850rpm 2850rpm 2850rpm

Max. Vertical Output 14m 14m 14m

Max. Horizontal Output

150m 150m 150m

Max. Flow Rate 400l/m 400l/m 400l/m

Max. Liquid Temperature

<40°C <40°C <40°C

Discharge Size 63mm OD 63mm OD 63mm OD

Cable Length 10m 10m 10m

Weight 135Kg 170Kg 210Kg

Colour White White White

DIMENSIONS

The Company reserves the right to make any alterations in the

interest of technical development.

MAGNAPRO™

Page 8: Product Catalogue - ESIcms.esi.info/Media/documents/Edinc_Catalog_ML.pdf · • Optimum performance of prthe pump system; • Improved environmental conditions. Our service agreements

1YEAR

One-year GuaranteeTerms and conditions apply.

ServiCe aGreementSIt is essential this product undergoes routine servicing. Please contact our service dept. for further information.

PACKAGED PUMPING STATIONS8

540–900 litre storage capacity

(depending on inlet level).

Magna900Pro

1300–2000 litre storage capacity

(depending on inlet level).

Magna2000Pro

The system is suitable for installing either at the

initial building stage or retro fitting to existing

buildings and can accept waste from a basement,

entire house/s or similar.

The system consists of a polyethylene tank,

locking access cover, internal pipework and

fittings, control panel, float switches with one or

two built in vortex submersible pumps.

The MagnaPro is easy to install as inlets can be

positioned to your requirements (inlet information

to be supplied at time of order).

The MagnaPro is a fully automatic

pumping station specifically designed

for pumping both foul and storm water

when gravity drainage is not possible or

economical to install.

For further information,

call 01442 211554 to

order your free

Magna brochure

Magna2000Pro

Magna900Pro

MAGNAPRO™ vortex model

ACCESSORIES

Recessed cover Additional inlets Kiosk

Telemetric system

MDPE / HDPE

AL

AR

M

Page 9: Product Catalogue - ESIcms.esi.info/Media/documents/Edinc_Catalog_ML.pdf · • Optimum performance of prthe pump system; • Improved environmental conditions. Our service agreements

Competitive range of packaged pumping stations

SPECIFICATIONSINSTALLATION gUIDELINES

9PACKAGED PUMPING STATIONS

Tel 01442 211554

Fax 01442 211553

[email protected]

www.edincare.com

For prices and additional information please

contact Sales on 01442 211554

It is important to note that these

instructions are for guidance only.

Please refer to the full Installation

and Operating Guidelines when

specifying / installing the product.

Siting the product

The MagnaPro is designed to be

installed below ground level and

so the prevailing ground conditions

must be considered prior to locating

the unit. Where possible, installation

of a pumping station in a roadway

should be avoided due to the need for

periodic maintenance of the pump(s)

contained therein. If the location is

adjacent to a roadway, the installation

method should take into account the

imposed loads likely to be transmitted

to the tank by traffic etc.

The MagnaPro should be positioned in

a sump with sufficient dimensions to

allow for a concrete surround.

Inlet connection

The MagnaPro comes complete with

a 110mm rubber connector located

on the side of the tank that will accept

110mm uPVC soil waste pipe. The

waste pipe needs to be run with

sufficient gradient to allow the waste

to gravity drain into the unit and should

be pushed firmly into the 110mm

rubber connector so as to form a

watertight seal around the incoming

pipe.

NOTE Inlets can be positioned to your

requirements but must be specified at

time of order.

Discharge connection

The connection of the discharge line is

via the supplied compression adaptor.

This connector is designed to accept

black MDPE / HDPE pipework of

appropriate outer diameter.

Electrical connection

A qualified person in accordance with

the Institute Of Electrical Engineers

Regulations should connect the

unit to the appropriate mains supply

taking into account all the electrical

information provided.

IMPORTANT – All pump systems

must be used with an appropriate

motor rated protection device.

Maintenance

We recommend that the unit be

inspected every three months. The

inside of the MagnaPro should

be inspected to ensure the floats

are clean and free of any build up

of materials that may inhibit the

operation of the float switch. Also the

moving parts of the pump(s) should

be checked to ensure that they are

moving freely. Hose down the interior

of the tank if necessary to remove

any build up of solid materials and

the bottom of the tank should be

checked to make sure there is no

debris or materials that could enter

the pump(s) and cause irreparable

damage.

In addition we recommend that a

service agreement be taken out with

a technically qualified company.

Health & safety

As with all site work, the danger of

working with water and electricity

can pose a severe threat to

health if obvious and fundamental

precautions are not taken. Therefore

if you are in any doubt regarding the

installation, please contact us.

All site work must be undertaken by

qualified personnel only.

These notes are for guidance only

and it is for the installer to ensure

the installation is in accordance

with all structural and regulatory

requirements.

Model Diameter Height

Magna900Pro 1100mm 1500mm

Magna2000Pro 1350mm 2000mm

Also available in Three Phase (400V AC) and both

single/twin pump setups. Please call for technical

specifications.

Model 900Pro 2000Pro

Power Supply 230V AC 230V AC

Rated Current 8.8A 8.8A

Motor Rating 1100W 1100W

Frequency 50Hz 50Hz

Revolutions per Minute 2900rpm 2900rpm

Max. Vertical Output 11m 11m

Max. Horizontal Output 100m 100m

Max. Flow Rate 600l/m 600l/m

Max. Liquid Temperature <40°C <40°C

Discharge Size 90mm OD 90mm OD

Cable Length 10m 10m

Weight 170Kg 210Kg

Colour White White

DIMENSIONS

The Company reserves the right to make any alterations in the

interest of technical development.

MAGNAPRO™

Page 10: Product Catalogue - ESIcms.esi.info/Media/documents/Edinc_Catalog_ML.pdf · • Optimum performance of prthe pump system; • Improved environmental conditions. Our service agreements

1YEAR

One-year GuaranteeTerms and conditions apply.

ServiCe aGreementSIt is essential this product undergoes routine servicing. Please contact our service dept. for further information.

PACKAGED PUMPING STATIONS10

MAGNAGRAND™

The Magnagrand is a fully automatic

pumping station suitable for pumping

both foul and storm water to a higher level

when gravity drainage is not possible or

economical to install.

The system is suitable for installing either

at the initial building stage or retro fitting to

existing buildings and can accept waste from

an entire house, housing estate, commercial

premises or similar.

The system consists of a GRP tank, locking

access cover, internal pipework and fittings,

control panel, float switches, guide rail/s with

one or two built in submersible pumps. The

tank is manufactured to your requirements,

tank sizes vary from 750mm–2500mm in

diameter and 1000mm to 6000mm in depth.

The MagnaGrand is easy to install as inlets

can be positioned to your requirements (inlet

information to be supplied at time of order).

For further information,

call 01442 211554 to

order your free

Magna brochureACCESSORIES

Recessed cover Additional inlets Kiosk

Telemetric system

MDPE / HDPE

AL

AR

M

Page 11: Product Catalogue - ESIcms.esi.info/Media/documents/Edinc_Catalog_ML.pdf · • Optimum performance of prthe pump system; • Improved environmental conditions. Our service agreements

SPECIFICATIONSINSTALLATION gUIDELINES

11PACKAGED PUMPING STATIONS

Tel 01442 211554

Fax 01442 211553

[email protected]

www.edincare.com

For prices and additional information please

contact Sales on 01442 211554

MAGNAGRAND™Versatile range of packaged pumping stations

It is important to note that these

instructions are for guidance

only. Please refer to the full

Installation and Operating

Guidelines when specifying /

installing the product.

Siting the product

The MagnaGrand is designed to be

installed below ground level and so

the prevailing ground conditions must

be considered prior to locating the

unit. Where possible, installation of a

pumping station in a roadway should

be avoided due to the need for

periodic maintenance of the pump(s)

contained therein. If the location is

adjacent to a roadway, the installation

method should take into account

the imposed loads likely to be

transmitted to the tank by traffic etc.

The MagnaGrand should be

positioned in a sump with sufficient

dimensions to allow for a concrete

surround.

Inlet connection

The MagnaGrand comes complete

with a 110mm rubber connector

located on the side of the tank that

will accept 110mm uPVC soil waste

pipe. The waste pipe needs to be

run with sufficient gradient to allow

the waste to gravity drain into the

unit and should be pushed firmly into

the 110mm rubber connector so as

to form a watertight seal around the

incoming pipe.

NOTE Inlets can be positioned

to your requirements but must be

specified at time of order.

Discharge connection

The connection of the discharge

line is via the supplied compression

adaptor. This connector is designed

to accept black MDPE / HDPE

pipework of appropriate outer

diameter.

Electrical connection

A qualified person in accordance with

the Institute Of Electrical Engineers

Regulations should connect the

unit to the appropriate mains supply

taking into account all the electrical

information provided.

IMPORTANT – All pump systems

must be used with an appropriate

motor rated protection device.

Maintenance

We recommend that the unit be

inspected every three months. The

inside of the MagnaGrand should

be inspected to ensure the floats

are clean and free of any build up

of materials that may inhibit the

operation of the float switch. Also the

moving parts of the pump(s) should

be checked to ensure that they are

moving freely. Hose down the interior

of the tank if necessary to remove

any build up of solid materials and

the bottom of the tank should be

checked to make sure there is no

debris or materials that could enter

the pump(s) and cause irreparable

damage.

In addition we recommend that a

service agreement be taken out with

a technically qualified company.

Health & safety

As with all site work, the danger of

working with water and electricity

can pose a severe threat to

health if obvious and fundamental

precautions are not taken. Therefore

if you are in any doubt regarding the

installation, please contact us.

All site work must be undertaken by

qualified personnel only.

These notes are for guidance only

and it is for the installer to ensure

the installation is in accordance

with all structural and regulatory

requirements.

The size of the chamber will vary depending on

your application. Chamber sizes vary from 750mm

to 2500mm in diameter and 1000mm to 6000mm

in depth.

We do not pre-specify pumps for the MagnaGrand

range as applications vary.

To enable us in advising on the appropriate pumping

station, please photocopy and complete the enquiry

specification form (page 69). Once completed,

please fax back to our sales office on 01442 211553.

We shall then select the most suitable system from

our full range to fulfil your requirements.

We offer single or three phase (230–400V AC) and

single or twin pump systems.

DIMENSIONS

The Company reserves the right to make any alterations in the

interest of technical development.

Page 12: Product Catalogue - ESIcms.esi.info/Media/documents/Edinc_Catalog_ML.pdf · • Optimum performance of prthe pump system; • Improved environmental conditions. Our service agreements

1YEAR

One-year GuaranteeTerms and conditions apply.

ServiCe aGreementSIt is essential this product undergoes routine servicing. Please contact our service dept. for further information.

PACKAGED PUMPING STATIONS12

MAGNASTANDARD™

The MagnaStandard is a fully automatic

small bore pumping station suitable for

pumping both foul and storm water to a

higher level when gravity drainage is not

possible or economical to install.

The system is suitable for installing either

at the initial building stage or retro fitting to

existing buildings and can accept waste from

a bathroom, kitchen, basement, changing

room or similar.

The system consists of a polyethylene tank,

locking access cover, internal pipework

and fittings with a built in automatic vortex

submersible pump.

The MagnaStandard is easy to install as inlets

can be positioned to your requirements (inlet

information to be supplied at time of order).

150 litre storage capacity.

200 litre storage capacity.

Magna200Standard

Magna150Standard

ACCESSORIES

MDPE Recessed coverHigh level alarm

(mains)High level alarm (mains&battery)

Additional inlets

Magna200Standard

Magna150Standard

Telemetric system

AL

AR

M

Page 13: Product Catalogue - ESIcms.esi.info/Media/documents/Edinc_Catalog_ML.pdf · • Optimum performance of prthe pump system; • Improved environmental conditions. Our service agreements

SPECIFICATIONSINSTALLATION gUIDELINES

13PACKAGED PUMPING STATIONS

Tel 01442 211554

Fax 01442 211553

[email protected]

www.edincare.com

For prices and additional information please

contact Sales on 01442 211554

It is important to note that these

instructions are for guidance only.

Please refer to the full Installation

and Operating Guidelines when

specifying / installing the product.

Siting the product

The MagnaStandard is designed to

be installed below ground level and

so the prevailing ground conditions

must be considered prior to locating

the unit. Where possible, installation

of a pumping station in a roadway

should be avoided due to the need

for periodic maintenance of the pump

contained therein. If the location is

adjacent to a roadway, the installation

method should take into account

the imposed loads likely to be

transmitted to the tank by traffic etc.

The MagnaStandard should be

positioned in a sump with a firm level

base and of sufficient dimensions to

allow for a concrete surround.

Inlet connection

The MagnaStandard comes complete

with a 110mm rubber connector

located on the side of the tank that

will accept 110mm uPVC soil waste

pipe. The waste pipe needs to be

run with sufficient gradient to allow

the waste to gravity drain into the

unit and should be pushed firmly into

the 110mm rubber connector so as

to form a watertight seal around the

incoming pipe.

NOTE – A 110mm inlet is positioned

on the opposite side to the discharge

outlet. Should you require a different

position / diameter this must be

specified at time of order.

Discharge connection

The connection of the discharge

line is via the supplied compression

adaptor. This connector is designed

to accept black MDPE / HDPE

pipework of appropriate outer

diameter.

Electrical connection

A qualified person in accordance with

the Institute Of Electrical Engineers

Regulations should connect the

unit to the appropriate mains supply

taking into account all the electrical

information provided.

IMPORTANT – All pump systems

must be used with an appropriate

motor rated protection device.

Maintenance

We recommend that the unit be

inspected every three months. The

inside of the MagnaStandard unit

should be inspected to ensure the

floats are clean and free of any build

up of materials that may inhibit the

operation of the float switch. Also

the moving parts of the pump should

be checked to ensure that they are

moving freely. Hose down the interior

of the tank if necessary to remove

any build up of solid materials and

the bottom of the tank should be

checked to make sure there is no

debris or materials that could enter

the pump and cause irreparable

damage.

In addition we recommend that a

service agreement be taken out with

a technically qualified company.

Health & safety

As with all site work, the danger of

working with water and electricity

can pose a severe threat to

health if obvious and fundamental

precautions are not taken. Therefore

if you are in any doubt regarding

the installation, please contact us.

All site work must be undertaken by

qualified personnel only.

These notes are for guidance only

and it is for the installer to ensure

the installation is in accordance

with all structural and regulatory

requirements.

Compact foul and storm water pumping stations MAGNASTANDARD™

Model 150Standard 200Standard

Power Supply 230V AC 230V AC

Rated Current 1.9A 7.3A

Motor Rating 250W 1100W

Frequency 50Hz 50Hz

Revolutions per Minute 3000rpm 2800rpm

Max. Vertical Output 8m 11m

Max. Horizontal Output 70m 100m

Max. Flow Rate 180l/m 600l/m

Max. Liquid Temperature <40°C <40°C

Discharge Size 50mm OD 63mm OD

Cable Length 10m 10m

Weight 40Kg 45Kg

Colour White White

Also available in Three Phase (400V AC), please call

for technical specifications.

DIMENSIONS

Model Length Width Height

Magna150Standard 700mm 550mm 550mm

Magna200Standard 700mm 550mm 900mm

The Company reserves the right to make any alterations in the

interest of technical development.

Page 14: Product Catalogue - ESIcms.esi.info/Media/documents/Edinc_Catalog_ML.pdf · • Optimum performance of prthe pump system; • Improved environmental conditions. Our service agreements

1YEAR

One-year GuaranteeTerms and conditions apply.

ServiCe aGreementSIt is essential this product undergoes routine servicing. Please contact our service dept. for further information.

PACKAGED PUMPING STATIONS14

MAGNACUTTER ™

The MagnaCutter is a fully automatic small

bore macerating pumping station suitable

for pumping both foul and storm water to

a higher level when gravity drainage is not

possible or economical to install.

The system is suitable for installing either

at the initial building stage or retro fitting to

existing buildings and can accept waste from

a bathroom, kitchen, basement, changing

room or similar.

The system consists of a polyethylene tank,

locking access cover, internal pipework and

fittings with a built in automatic macerating

submersible pump.

The MagnaCutter is easy to install as inlets

can be positioned to your requirements (inlet

information to be supplied at time of order).

150 litre storage capacity.

200 litre storage capacity.

Magna200Cutter

Magna150Cutter

ACCESSORIES

MDPE Recessed cover

Additional inlets

High level alarm(mains)

High level alarm (mains&battery)

Magna200Cutter

Magna150Cutter

Telemetric system

AL

AR

M

Page 15: Product Catalogue - ESIcms.esi.info/Media/documents/Edinc_Catalog_ML.pdf · • Optimum performance of prthe pump system; • Improved environmental conditions. Our service agreements

SPECIFICATIONSINSTALLATION gUIDELINES

15PACKAGED PUMPING STATIONS

Tel 01442 211554

Fax 01442 211553

[email protected]

www.edincare.com

For prices and additional information please

contact Sales on 01442 211554

MAGNACUTTER™Compact foul and storm water pumping stations

It is important to note that these

instructions are for guidance only.

Please refer to the full Installation

and Operating Guidelines when

specifying / installing the product.

Siting the product

The MagnaCutter is designed to

be installed below ground level and

so the prevailing ground conditions

must be considered prior to locating

the unit. Where possible, installation

of a pumping station in a roadway

should be avoided due to the need

for periodic maintenance of the pump

contained therein. If the location is

adjacent to a roadway, the installation

method should take into account

the imposed loads likely to be

transmitted to the tank by traffic etc.

The MagnaCutter should be

positioned in a sump with a firm level

base and of sufficient dimensions to

allow for a concrete surround.

Inlet connection

The MagnaCutter comes complete

with a 110mm rubber connector

located on the side of the tank that

will accept 110mm uPVC soil waste

pipe. The waste pipe needs to be

run with sufficient gradient to allow

the waste to gravity drain into the

unit and should be pushed firmly into

the 110mm rubber connector so as

to form a watertight seal around the

incoming pipe.

NOTE – A 110mm inlet is positioned

on the opposite side to the discharge

outlet. Should you require a different

position / diameter this must be

specified at time of order.

Discharge connection

The connection of the discharge

line is via the supplied compression

adaptor. This connector is designed

to accept black MDPE / HDPE

pipework of appropriate outer

diameter.

Electrical connection

A qualified person in accordance with

the Institute Of Electrical Engineers

Regulations should connect the

unit to the appropriate mains supply

taking into account all the electrical

information provided.

IMPORTANT – All pump systems

must be used with an appropriate

motor rated protection device.

Maintenance

We recommend that the unit be

inspected every three months.

The inside of the MagnaCutter unit

should be inspected to ensure the

floats are clean and free of any build

up of materials that may inhibit the

operation of the float switch. Also

the moving parts of the pump should

be checked to ensure that they are

moving freely. Hose down the interior

of the tank if necessary to remove

any build up of solid materials and

the bottom of the tank should be

checked to make sure there is no

debris or materials that could enter

the pump and cause irreparable

damage.

In addition we recommend that a

service agreement be taken out with

a technically qualified company.

Health & safety

As with all site work, the danger of

working with water and electricity

can pose a severe threat to

health if obvious and fundamental

precautions are not taken. Therefore

if you are in any doubt regarding

the installation, please contact us.

All site work must be undertaken by

qualified personnel only.

These notes are for guidance only

and it is for the installer to ensure

the installation is in accordance

with all structural and regulatory

requirements.

Model 150Cutter 200Cutter

Power Supply 230V AC 230V AC

Rated Current 6.4A 5.1A

Motor Rating 1000W 750W

Frequency 50Hz 50Hz

Revolutions per Minute 2900rpm 2850rpm

Max. Vertical Output 21m 14m

Max. Horizontal Output 250m 150m

Max. Flow Rate 132l/m 400l/m

Max. Liquid Temperature <40°C <40°C

Discharge Size 32mm OD 63mm OD

Cable Length 5m 10m

Weight 40Kg 52Kg

Colour White White

Also available in Three Phase (400V AC), please call

for technical specifications.

DIMENSIONS

Model Length Width Height

Magna150Cutter 700mm 550mm 550mm

Magna200Cutter 700mm 550mm 900mm

The Company reserves the right to make any alterations in the

interest of technical development.

Page 16: Product Catalogue - ESIcms.esi.info/Media/documents/Edinc_Catalog_ML.pdf · • Optimum performance of prthe pump system; • Improved environmental conditions. Our service agreements

1YEAR

One-year GuaranteeTerms and conditions apply.

ServiCe aGreementSIt is essential this product undergoes routine servicing. Please contact our service dept. for further information.

WASTE WATER PUMPING SYSTEMS16

AUTOFLUSHXL ™

The AutoFlushXL is a fully automatic

waste water pumping system suitable

for pumping grey water to a higher level

when gravity drainage is not possible or

economical to install.

The system is suitable for installing either at the

initial building stage or retro fitting to existing

buildings and can accept waste connections from

a domestic sink, washing machine, dishwasher or

similar.

The system consists of a polyethylene odour

tight tank with a built in automatic waste water

submersible pump.

The AutoFlushXL is easy to install as inlets can be

positioned to your requirements (inlet information

to be supplied at time of order).

AutoFlush90XL

AutoFlush30XL

90 litre storage capacity.

30 litre storage capacity.

ACCESSORIES

High level alarm(mains)

High level alarm (mains&battery) Low level float Telemetric system

AL

AR

M

Page 17: Product Catalogue - ESIcms.esi.info/Media/documents/Edinc_Catalog_ML.pdf · • Optimum performance of prthe pump system; • Improved environmental conditions. Our service agreements

SPECIFICATIONSINSTALLATION gUIDELINES

17WASTE WATER PUMPING SYSTEMS

Tel 01442 211554

Fax 01442 211553

[email protected]

www.edincare.com

For prices and additional information please

contact Sales on 01442 211554

AUTOFLUSHXL™A powerful range of waste water pumping systems

It is important to note that these

instructions are for guidance only.

Please refer to the full Installation

and Operating Guidelines when

specifying / installing the product.

Siting the product

The AutoFlushXL should be

positioned on a firm level surface,

resistant to condensation. The unit

must be located lower than the

outflow of the appliances served so

as to provide a gravity fall into the

unit.

It is extremely important to site the

AutoFlushXL with access in mind

in the event of maintenance being

required.

Inlet connections

The AutoFlushXL comes as standard

complete with 1no. 32mm rubber

connector located on the lid of the

unit.

The rubber inlet connector

is designed to accept 32mm

uPVC waste pipe and should be

pushed approximately 40mm

into the connector which will then

form a watertight seal around

the incoming waste pipe.

NOTE – Inlets can be positioned

on the AutoFlushXL to suit your

site requirements (details on inlet

positions must be supplied when

ordering).

Discharge connection

The discharge line must be

connected to the AutoFlushXL via the

tank connector on the side of the unit.

The tank connector will accept 32mm

uPVC waste pipe.

All joins in the discharge line must

be made with solvent cement, under

no circumstances should push fit or

compression fittings be used.

The AutoFlushXL is designed for one

lift only and the vertical lift should be

within 500mm of the unit.

IMPORTANT – It is recommended

that there are no bends in the vertical

lift, however if this is unavoidable a

minimum of slow radius bends may

be used.

Electrical connection

A qualified person in accordance with

the Institute Of Electrical Engineers

Regulations should connect the

unit to the appropriate mains supply

taking into account all the electrical

information provided.

IMPORTANT – All pump systems

must be used with an appropriate

motor rated protection device.

Maintenance

The AutoFlushXL requires minimal

maintenance. Basic common

sense and good housekeeping

will ensure the best results. It is

recommended that the unit be

rinsed through with warm water and

a minimum of bleach and washing

up liquid added (approx. every 1–2

weeks). This should stop any milk

residue and other fatty deposits

being allowed to accumulate, go

rancid and produce bad odours.

Once or twice yearly it is

recommended that the unit be

inspected. The lid should be removed

and the tank and float cleaned.

Health & safety

As with all site work, the danger of

working with water and electricity

can pose a severe threat to

health if obvious and fundamental

precautions are not taken. Therefore

if you are in any doubt regarding

the installation, please contact us.

All site work must be undertaken by

qualified personnel only.

These notes are for guidance only

and it is for the installer to ensure

the installation is in accordance

with all structural and regulatory

requirements.

Model Length Width Height

AutoFlush30XL 400mm 300mm 350mm

AutoFlush90XL 600mm 400mm 450mm

Model AutoFlush30XL AutoFlush90XL

Power Supply 230V AC 230V AC

Rated Current 1.4A 3.6A

Motor Rating 320W 700W

Frequency 50Hz 50Hz

Revolutions per Minute

2720rpm 2800rpm

Max. Vertical Output 7m 12m

Max. Horizontal Output

50m 100m

Horizontal Fall 1:200 1:200

Max. Flow Rate 108l/m 240l/m

Max. Liquid Temp. <40°C <40°C

Discharge Size 32mm 32mm

Cable Length 3m 3m

Weight 9kg 14kg

Colour White White

DIMENSIONS

The Company reserves the right to make any alterations in the

interest of technical development.

Page 18: Product Catalogue - ESIcms.esi.info/Media/documents/Edinc_Catalog_ML.pdf · • Optimum performance of prthe pump system; • Improved environmental conditions. Our service agreements

1YEAR

One-year GuaranteeTerms and conditions apply.

ServiCe aGreementSIt is essential this product undergoes routine servicing. Please contact our service dept. for further information.

WASTE WATER PUMPING SYSTEMS18

AUTOFLUSHVOX ™

The AutoFlushvOX is a fully automatic

waste water pumping system suitable for

pumping grey water containing particles

to a higher level when gravity drainage is

not possible or economical to install.

The system is suitable for installing either at the

initial building stage or retro fitting to existing

buildings and can accept waste connections from

a sink, coffee machine or similar.

The system consists of a polyethylene odour tight

tank with a built in automatic vortex submersible

pump.

The AutoFlushVOX is easy to install as inlets

can be positioned to your requirements (inlet

information to be supplied at time of order).

AutoFlush90vOX

AutoFlush30vOX

90 litre storage capacity.

30 litre storage capacity.

ACCESSORIES

High level alarm(mains)

High level alarm (mains&battery) Telemetric system

AL

AR

M

Page 19: Product Catalogue - ESIcms.esi.info/Media/documents/Edinc_Catalog_ML.pdf · • Optimum performance of prthe pump system; • Improved environmental conditions. Our service agreements

SPECIFICATIONSINSTALLATION gUIDELINES

19WASTE WATER PUMPING SYSTEMS

Tel 01442 211554

Fax 01442 211553

[email protected]

www.edincare.com

For prices and additional information please

contact Sales on 01442 211554

AUTOFLUSHVOX™A powerful range of waste water pumping systems

It is important to note that these

instructions are for guidance only.

Please refer to the full Installation

and Operating Guidelines when

specifying / installing the product.

Siting the product

The AutoFlushVOX should be posi-

tioned on a firm level surface, resistant

to condensation. The unit must be

located lower than the outflow of the

appliances served so as to provide a

gravity fall into the unit.

It is extremely important to site the

AutoFlushVOX with access in mind

in the event of maintenance being

required.

Inlet connections

The AutoFlushVOX comes as standard

complete with 1no. 32mm rubber

connector located on the lid of the

unit.

The rubber inlet connector is designed

to accept 32mm uPVC waste pipe

and should be pushed approximately

40mm into the connector which will

then form a watertight seal around the

incoming waste pipe.

NOTE – Inlets can be positioned on

the AutoFlushVOX to suit your site

requirements (details on inlet positions

must be supplied when ordering).

Discharge connection

The discharge line must be

connected to the AutoFlushVOX via

the connector on the side of the unit.

The pipework required to connect

to the AutoFlush30VOX should be

32mm uPVC waste pipe. To connect

to the AutoFlush90VOX the pipework

required is 1½" PVC Class E pressure

pipe.

All joins in the discharge line must

be made with solvent cement, under

no circumstances should push fit or

compression fittings be used.

The AutoFlushVOX is designed for one

lift only and the vertical lift should be

within 500mm of the unit.

IMPORTANT – It is recommended

that there are no bends in the vertical

lift, however if this is unavoidable a

minimum of slow radius bends may

be used.

Electrical connection

A qualified person in accordance with

the Institute Of Electrical Engineers

Regulations should connect the

unit to the appropriate mains supply

taking into account all the electrical

information provided.

IMPORTANT – All pump systems

must be used with an appropriate

motor rated protection device.

Maintenance

The AutoFlushVOX requires minimal

maintenance. Basic common sense

and good housekeeping will ensure

the best results. It is recommended

that the unit be rinsed through with

warm water and a minimum of

bleach and washing up liquid added

(approx. every 1–2 weeks). This

should stop any milk residue and

other fatty deposits being allowed to

accumulate, go rancid and produce

bad odours.

Once or twice yearly it is

recommended that the unit be

inspected. The lid should be removed

and the tank and float cleaned.

Health & safety

As with all site work, the danger of

working with water and electricity

can pose a severe threat to

health if obvious and fundamental

precautions are not taken. Therefore

if you are in any doubt regarding the

installation, please contact us.

All site work must be undertaken by

qualified personnel only.

These notes are for guidance only

and it is for the installer to ensure

the installation is in accordance

with all structural and regulatory

requirements.

Model AutoFlush30vOX AutoFlush90vOX

Power Supply 230V AC 230V AC

Rated Current 1.4A 1.9A

Motor Rating 150W 250W

Frequency 50Hz 50Hz

Revolutions per Minute

3000rpm 3000rpm

Max. Vertical Output 7m 8m

Max. Horizontal Output

50m 70m

Horizontal Fall 1:200 1:200

Max. Flow Rate 120l/m 180l/m

Max. Liquid Temp. <40°C <40°C

Discharge Size 32mm 1½"

Cable Length 10m 10m

Weight 11.5kg 15.5kg

Colour White White

Model Length Width Height

AutoFlush30VOX 400mm 300mm 350mm

AutoFlush90VOX 600mm 400mm 450mm

DIMENSIONS

The Company reserves the right to make any alterations in the

interest of technical development.

Page 20: Product Catalogue - ESIcms.esi.info/Media/documents/Edinc_Catalog_ML.pdf · • Optimum performance of prthe pump system; • Improved environmental conditions. Our service agreements

1YEAR

One-year GuaranteeTerms and conditions apply.

ServiCe aGreementSIt is essential this product undergoes routine servicing. Please contact our service dept. for further information.

WASTE WATER PUMPING SYSTEMS20

AUTOFLUSHCSL ™

ACCESSORIES

Low level float

The AutoFlushCSL is a fully automatic waste

water pumping system suitable for pumping

waste water containing mildly aggressive

chemicals to a higher level when gravity drainage

is not possible or economical to install.

The system is suitable for installing either at the

initial building stage or retro fitting to existing

buildings and can accept waste connections from

a cleaners/photo lab sink or similar.

The system consists of a polyethylene odour tight

tank with a built in automatic mechanically sealed

submersible pump.

The AutoFlushCSL is easy to install as inlets

can be positioned to your requirements (inlet

information to be supplied at time of order).

AutoFlush90CSL

AutoFlush30CSL

90 litre storage capacity.

30 litre storage capacity.

High level alarm(mains)

High level alarm (mains&battery) Telemetric system

AL

AR

M

Page 21: Product Catalogue - ESIcms.esi.info/Media/documents/Edinc_Catalog_ML.pdf · • Optimum performance of prthe pump system; • Improved environmental conditions. Our service agreements

SPECIFICATIONSINSTALLATION gUIDELINES

21WASTE WATER PUMPING SYSTEMS

Tel 01442 211554

Fax 01442 211553

[email protected]

www.edincare.com

For prices and additional information please

contact Sales on 01442 211554

AUTOFLUSHCSL™A powerful range of waste water pumping systems

It is important to note that these

instructions are for guidance only.

Please refer to the full Installation

and Operating Guidelines when

specifying / installing the product.

Siting the product

The AutoFlushCSL should be

positioned on a firm level surface,

resistant to condensation. The unit

must be located lower than the

outflow of the appliances served so as

to provide a gravity fall into the unit.

It is extremely important to site the

AutoFlushCSL with access in mind

in the event of maintenance being

required.

Inlet connections

The AutoFlushCSL comes as

standard complete with 1no. 32mm

rubber connector located on the lid

of the unit.

The rubber inlet connector is

designed to accept 32mm uPVC

waste pipe and should be pushed

approximately 40mm into the

connector which will then form a

watertight seal around the incoming

waste pipe.

NOTE – Inlets can be positioned

on the AutoFlushCSL to suit your

site requirements (details on inlet

positions must be supplied when

ordering).

Discharge connection

The discharge line must be

connected to the AutoFlushCSL

via the tank connector on the side

of the unit. The tank connector will

accept 32mm uPVC waste pipe. All

joins in the discharge line must be

made with solvent cement, under

no circumstances should push fit or

compression fittings be used.

The AutoFlushCSL is designed for

one lift only and the vertical lift should

be within 500mm of the unit.

IMPORTANT – It is recommended

that there are no bends in the vertical

lift, however if this is unavoidable a

minimum of slow radius bends may

be used.

Electrical connection

A qualified person in accordance with

the Institute Of Electrical Engineers

Regulations should connect the

unit to the appropriate mains supply

taking into account all the electrical

information provided.

IMPORTANT – All pump systems

must be used with an appropriate

motor rated protection device.

Maintenance

The AutoFlushCSL requires minimal

maintenance. Basic common

sense and good housekeeping

will ensure the best results. It is

recommended that the unit be

rinsed through with warm water and

a minimum of bleach and washing

up liquid added (approx. every 1–2

weeks). This should stop any milk

residue and other fatty deposits

being allowed to accumulate, go

rancid and produce bad odours.

Once or twice yearly it is

recommended that the unit be

inspected. The lid should be removed

and the tank and float cleaned.

Health & safety

As with all site work, the danger of

working with water and electricity

can pose a severe threat to

health if obvious and fundamental

precautions are not taken. Therefore

if you are in any doubt regarding

the installation, please contact us.

All site work must be undertaken by

qualified personnel only.

These notes are for guidance only

and it is for the installer to ensure

the installation is in accordance

with all structural and regulatory

requirements.

Model AutoFlush30CSL AutoFlush90CSL

Power Supply 230V AC 230V AC

Rated Current 1.4A 1.4A

Motor Rating 320W 320W

Frequency 50Hz 50Hz

Revolutions per Minute

2720rpm 2720rpm

Max. Vertical Output 7m 7m

Max. Horizontal Output

50m 50m

Horizontal Fall 1:200 1:200

Max. Flow Rate 108l/m 108l/m

Max. Liquid Temp. <40°C <40°C

Discharge Size 32mm 32mm

Cable Length 3m 3m

Weight 9kg 11kg

Colour White White

Model Length Width Height

AutoFlush30CSL 400mm 300mm 350mm

AutoFlush90CSL 600mm 400mm 450mm

DIMENSIONS

The Company reserves the right to make any alterations in the

interest of technical development.

Page 22: Product Catalogue - ESIcms.esi.info/Media/documents/Edinc_Catalog_ML.pdf · • Optimum performance of prthe pump system; • Improved environmental conditions. Our service agreements

1YEAR

One-year GuaranteeTerms and conditions apply.

ServiCe aGreementSIt is essential this product undergoes routine servicing. Please contact our service dept. for further information.

WASTE WATER PUMPING SYSTEMS22

AUTOFLUSHTWIN ™

The AutoFlushTwin is a fully automatic

waste water twin pumping system suitable

for pumping grey water to a higher level

when gravity drainage is not possible or

economical to install.

The system is suitable for installing either at the

initial building stage or retro fitting to existing

buildings and can accept waste connections from

a sink, washing machine, dishwasher or similar.

The system consists of a polyethylene odour tight

tank with two built in waste water submersible

pumps, operated via a control panel.

The AutoFlushTwin is easy to install as inlets

can be positioned to your requirements (inlet

information to be supplied at time of order).

ACCESSORIES

Telemetric system

AL

AR

M

Page 23: Product Catalogue - ESIcms.esi.info/Media/documents/Edinc_Catalog_ML.pdf · • Optimum performance of prthe pump system; • Improved environmental conditions. Our service agreements

SPECIFICATIONSINSTALLATION gUIDELINES

23WASTE WATER PUMPING SYSTEMS

Tel 01442 211554

Fax 01442 211553

[email protected]

www.edincare.com

For prices and additional information please

contact Sales on 01442 211554

AUTOFLUSHTWIN ™A powerful twin waste water pumping system

It is important to note that these

instructions are for guidance only.

Please refer to the full Installation

and Operating Guidelines when

specifying / installing the product.

Siting the product

The AutoFlushTwin should be

positioned on a firm level surface,

resistant to condensation. The unit

must be located lower than the

outflow of the appliances served so as

to provide a gravity fall into the unit.

It is extremely important to site the

AutoFlushTwin with access in mind

in the event of maintenance being

required.

Inlet connections

The AutoFlushTwin comes as

standard complete with 1no. 32mm

rubber connector located on the lid

of the unit.

The rubber inlet connector is

designed to accept 32mm uPVC

waste pipe and should be pushed

approximately 40mm into the

connector which will then form a

watertight seal around the incoming

waste pipe.

NOTE – Inlets can be positioned

on the AutoFlushTwin to suit your

site requirements (details on inlet

positions must be supplied when

ordering).

Discharge connection

The discharge line must be

connected to the AutoFlushTwin

via the tank connector on the side

of the unit. The tank connector will

accept 32mm uPVC waste pipe. All

joins in the discharge line must be

made with solvent cement, under

no circumstances should push fit or

compression fittings be used.

The AutoFlushTwin is designed for

one lift only and the vertical lift should

be within 500mm of the unit.

IMPORTANT – It is recommended

that there are no bends in the vertical

lift, however if this is unavoidable a

minimum of slow radius bends may

be used.

Electrical connection

A qualified person in accordance with

the Institute Of Electrical Engineers

Regulations should connect the

unit to the appropriate mains supply

taking into account all the electrical

information provided.

IMPORTANT – All pump systems

must be used with an appropriate

motor rated protection device.

Maintenance

The AutoFlushTwin requires minimal

maintenance. Basic common sense

and good housekeeping will ensure

the best results. It is recommended

that the unit be rinsed through with

warm water and a minimum of

bleach and washing up liquid added

(approx. every 1–2 weeks). This

should stop any milk residue and

other fatty deposits being allowed to

accumulate, go rancid and produce

bad odours.

Once or twice yearly it is

recommended that the unit be

inspected. The lid should be removed

and the tank and float cleaned.

Health & safety

As with all site work, the danger of

working with water and electricity

can pose a severe threat to

health if obvious and fundamental

precautions are not taken. Therefore

if you are in any doubt regarding

the installation, please contact us.

All site work must be undertaken by

qualified personnel only.

These notes are for guidance only

and it is for the installer to ensure

the installation is in accordance

with all structural and regulatory

requirements.

Model AutoFlushTwin

Power Supply 230V AC

Rated Current 1.4A Per Pump

Motor Rating 320W

Frequency 50Hz

Revolutions per Minute

2720rpm

Max. Vertical Output 7m

Max. Horizontal Output

50m

Horizontal Fall 1:200

Max. Flow Rate 108l/m

Max. Liquid Temp. <40°C

Discharge Size 32mm

Cable Length 3m

Weight 16.5kg

Colour White

Model Length Width Height

AutoFlushTwin 600mm 400mm 450mm

DIMENSIONS

The Company reserves the right to make any alterations in the

interest of technical development.

Page 24: Product Catalogue - ESIcms.esi.info/Media/documents/Edinc_Catalog_ML.pdf · • Optimum performance of prthe pump system; • Improved environmental conditions. Our service agreements

1YEAR

One-year GuaranteeTerms and conditions apply.

ServiCe aGreementSIt is essential this product undergoes routine servicing. Please contact our service dept. for further information.

WASTE WATER PUMPING SYSTEMS24

AUTOFLUSHHT ™

The AutoFlushHT is a fully automatic high

temperature waste water pumping system suitable

for pumping hot water containing particles to a

higher level when gravity drainage is not possible

or economical to install.

The system is suitable for installing either at the

initial building stage or retro fitting to existing

buildings and can accept waste connections from

a commercial sink, washing machine, dishwasher

or similar.

The system consists of an odour tight GRP tank

with a built in automatic high temperature vortex

submersible pump. The system can accept

waste water up to 90°C making it very versatile in

commercial applications.

The AutoFlushHT is easy to install as inlets can be

positioned to your requirements (inlet information

to be supplied at time of order).

AutoFlush160HT

AutoFlush60HT

160 litre storage capacity.

60 litre storage capacity.

ACCESSORIES

Low level floatHigh level alarm

(mains)High level alarm (mains&battery) Telemetric system

AL

AR

M

Page 25: Product Catalogue - ESIcms.esi.info/Media/documents/Edinc_Catalog_ML.pdf · • Optimum performance of prthe pump system; • Improved environmental conditions. Our service agreements

SPECIFICATIONSINSTALLATION gUIDELINES

25WASTE WATER PUMPING SYSTEMS

Tel 01442 211554

Fax 01442 211553

[email protected]

www.edincare.com

For prices and additional information please

contact Sales on 01442 211554

AUTOFLUSHHT ™A range of high temperature waste water pumping systems

It is important to note that these

instructions are for guidance only.

Please refer to the full Installation

and Operating Guidelines when

specifying / installing the product.

Siting the product

The AutoFlushHT should be

positioned on a firm level surface,

resistant to condensation. The unit

must be located lower than the

outflow of the appliances served so

as to provide a gravity fall into the

unit.

It is extremely important to site the

AutoFlushHT with access in mind

in the event of maintenance being

required.

Inlet connections

The AutoFlushHT comes as standard

complete with 1no. 32/40mm tank

connector located on the lid of the

unit.

The uPVC tank connector is designed

to accept 32/40mm uPVC waste pipe

and should be secured into place

using solvent cement.

NOTE – Inlets can be positioned

on the AutoFlushHT to suit your

site requirements (details on inlet

positions and inlet diameter must be

supplied when ordering).

Discharge connection

The discharge line must be

connected to the AutoFlushHT via

the tank connector on the side of the

unit and will accept 1½" PVC Class E

pressure pipe.

All joins in the discharge line must

be made with solvent cement, under

no circumstances should push fit or

compression fittings be used.

The AutoFlushHT is designed for one

lift only and the vertical lift should be

within 500mm of the unit.

IMPORTANT – It is recommended

that there are no bends in the vertical

lift, however if this is unavoidable a

minimum of slow radius bends may

be used.

Electrical connection

A qualified person in accordance with

the Institute Of Electrical Engineers

Regulations should connect the

unit to the appropriate mains supply

taking into account all the electrical

information provided.

IMPORTANT – All pump systems

must be used with an appropriate

motor rated protection device.

Maintenance

The AutoFlushHT requires minimal

maintenance. Basic common sense

and good housekeeping will ensure

the best results. It is recommended

that the unit be rinsed through with

warm water and a minimum of

bleach and washing up liquid added

(approx. every 1–2 weeks). This

should stop any milk residue and

other fatty deposits being allowed to

accumulate, go rancid and produce

bad odours.

Once or twice yearly it is

recommended that the unit be

inspected. The lid should be removed

and the tank and float cleaned.

Health & safety

As with all site work, the danger of

working with water and electricity

can pose a severe threat to

health if obvious and fundamental

precautions are not taken. Therefore

if you are in any doubt regarding

the installation, please contact us.

All site work must be undertaken by

qualified personnel only.

These notes are for guidance only

and it is for the installer to ensure

the installation is in accordance

with all structural and regulatory

requirements.

Model AutoFlush60HT AutoFlush160HT

Power Supply 230V AC 230V AC

Rated Current 3.9A 3.9A

Motor Rating 830W 830W

Frequency 50Hz 50Hz

Revolutions per Minute

2510rpm 2510rpm

Max. Vertical Output 10m 10m

Max. Horizontal Output

70m 70m

Horizontal Fall 1:200 1:200

Max. Flow Rate 330l/m 330l/m

Max. Liquid Temp. <90°C <90°C

Discharge Size 1½" 1½"

Cable Length 3m 3m

Weight 18kg 20kg

Colour White White

Model Length Width Height

AutoFlush60HT 500mm 300mm 450mm

AutoFlush160HT 600mm 600mm 450mm

DIMENSIONS

The Company reserves the right to make any alterations in the

interest of technical development.

Page 26: Product Catalogue - ESIcms.esi.info/Media/documents/Edinc_Catalog_ML.pdf · • Optimum performance of prthe pump system; • Improved environmental conditions. Our service agreements

1YEAR

One-year GuaranteeTerms and conditions apply.

ServiCe aGreementSIt is essential this product undergoes routine servicing. Please contact our service dept. for further information.

WASTE WATER PUMPING SYSTEMS26

AUTOFLUSHHTTWIN ™

The AutoFlushHTTwin is a fully automatic high

temperature twin waste water pumping system

suitable for pumping hot water containing particles

to a higher level when gravity drainage is not

possible or economical to install.

The system is suitable for installing either

at the initial building stage or retro fitting

to existing buildings and can accept waste

connections from a commercial sink,

washing machine, dishwasher or similar.

The system consists of a GRP odour tight

tank with two built in high temperature

vortex submersible pumps operated via a

control panel. The system can accept waste

water up to 90°C making it very versatile in

commercial applications.

The AutoFlushHTTwin is easy to install

as inlets can be positioned to your

requirements (inlet information to be

supplied at time of order).

ACCESSORIES

Low level float Telemetric system

AL

AR

M

Page 27: Product Catalogue - ESIcms.esi.info/Media/documents/Edinc_Catalog_ML.pdf · • Optimum performance of prthe pump system; • Improved environmental conditions. Our service agreements

SPECIFICATIONSINSTALLATION gUIDELINES

27WASTE WATER PUMPING SYSTEMS

Tel 01442 211554

Fax 01442 211553

[email protected]

www.edincare.com

For prices and additional information please

contact Sales on 01442 211554

AUTOFLUSHHTTWIN ™A high temperature waste water pumping system

It is important to note that these

instructions are for guidance only.

Please refer to the full Installation

and Operating Guidelines when

specifying / installing the product.

Siting the product

The AutoFlushHTTwin should be

positioned on a firm level surface,

resistant to condensation. The unit

must be located lower than the

outflow of the appliances served so as

to provide a gravity fall into the unit.

It is extremely important to site the

AutoFlushHTTwin with access in mind

in the event of maintenance being

required.

Inlet connections

The AutoFlushHTTwin comes

as standard complete with

1no. 32/40mm tank connector

located on the lid of the unit.

The uPVC tank connector is designed

to accept 32/40mm uPVC waste pipe

and should be secured into place

using solvent cement.

NOTE – Inlets can be positioned on

the AutoFlushHTTwin to suit your

site requirements (details on inlet

positions and inlet diameter must be

supplied when ordering).

Discharge connection

The discharge line must be

connected to the AutoFlushHTTwin

via the tank connector on the side

of the unit and will accept 1½" PVC

Class E pressure pipe.

All joins in the discharge line must

be made with solvent cement, under

no circumstances should push fit or

compression fittings be used.

The AutoFlushHTTwin is designed for

one lift only and the vertical lift should

be within 500mm of the unit.

IMPORTANT – It is recommended

that there are no bends in the vertical

lift, however if this is unavoidable a

minimum of slow radius bends may

be used.

Electrical connection

A qualified person in accordance with

the Institute Of Electrical Engineers

Regulations should connect the

unit to the appropriate mains supply

taking into account all the electrical

information provided.

IMPORTANT – All pump systems

must be used with an appropriate

motor rated protection device.

Maintenance

The AutoFlushHTTwin requires

minimal maintenance. Basic common

sense and good housekeeping

will ensure the best results. It is

recommended that the unit be

rinsed through with warm water and

a minimum of bleach and washing

up liquid added (approx. every 1–2

weeks). This should stop any milk

residue and other fatty deposits

being allowed to accumulate, go

rancid and produce bad odours.

Once or twice yearly it is

recommended that the unit be

inspected. The lid should be removed

and the tank and float cleaned.

Health & safety

As with all site work, the danger of

working with water and electricity

can pose a severe threat to

health if obvious and fundamental

precautions are not taken. Therefore

if you are in any doubt regarding

the installation, please contact us.

All site work must be undertaken by

qualified personnel only.

These notes are for guidance only

and it is for the installer to ensure

the installation is in accordance

with all structural and regulatory

requirements.

Model AutoFlushHTTwin

Power Supply 230V AC

Rated Current 3.9A Per Pump

Motor Rating 830W

Frequency 50Hz

Revolutions per Minute

2510rpm

Max. Vertical Output 10m

Max. Horizontal Output

70m

Horizontal Fall 1:200

Max. Flow Rate 330l/m

Max. Liquid Temp. <90°C

Discharge Size 1½"

Cable Length 3m

Weight 34kg

Colour White

Model Length Width Height

AutoFlushHTTwin 600mm 600mm 450mm

DIMENSIONS

The Company reserves the right to make any alterations in the

interest of technical development.

Page 28: Product Catalogue - ESIcms.esi.info/Media/documents/Edinc_Catalog_ML.pdf · • Optimum performance of prthe pump system; • Improved environmental conditions. Our service agreements

1YEAR

One-year GuaranteeTerms and conditions apply.

ServiCe aGreementSIt is essential this product undergoes routine servicing. Please contact our service dept. for further information.

WASTE WATER PUMPING SYSTEMS28

AQUAFLUSH ™

The AquaFlush is a fully automatic

waste water pumping system suitable

for pumping grey water to a higher level

when gravity drainage is not possible or

economical to install.

The system is suitable for installing either at the

initial building stage or retro fitting to existing

buildings and can accept waste connections from

a sink, washing machine, dishwasher or similar.

The system consists of an odour tight tank with a

built in automatic waste water submersible pump.

The AquaFlush is easy to install as there are five

pre-moulded inlets, 2 either side and 1 located on

the top of the system.

AquaFlushMF

AquaFlush

High head AquaFlush MF.

Standard AquaFlush.

ACCESSORIES

High level alarm(mains)

High level alarm (mains&battery) Telemetric system

AL

AR

M

Page 29: Product Catalogue - ESIcms.esi.info/Media/documents/Edinc_Catalog_ML.pdf · • Optimum performance of prthe pump system; • Improved environmental conditions. Our service agreements

SPECIFICATIONSINSTALLATION gUIDELINES

29WASTE WATER PUMPING SYSTEMS

Tel 01442 211554

Fax 01442 211553

[email protected]

www.edincare.com

For prices and additional information please

contact Sales on 01442 211554

AQUAFLUSH ™Flexible waste water pumping systems

It is important to note that these

instructions are for guidance only.

Please refer to the full Installation

and Operating Guidelines when

specifying / installing the product.

Siting the product

The AquaFlush should be positioned

on a firm level surface, resistant to

condensation. The unit must be

located lower than the outflow of the

appliances served so as to provide a

gravity fall into the unit.

It is extremely important to site the

AquaFlush with access in mind in the

event of maintenance being required.

Inlet connections

The AquaFlush comes complete with

5 inlet connection ports and rubber

seals to suit 32/40mm uPVC waste

pipe. The incoming pipework from the

appliances served should be pushed

into the rubber seal approximately

30mm, which will then form a

watertight seal around the pipework.

Blanking caps and seals are provided

to seal off any of the pre-cut inlets

that are not required.

Discharge connection

The discharge line can exit through

either the left or right hand side of

the unit by rotating the rubber bend

on the pump to suit. The connecting

pipework must be 32mm PVC waste

pipe and should be pushed into the

non-return valve and secured into

place using the jubilee clips provided.

All joins in the discharge line must be

made using solvent cement, under

no circumstances should push fit or

compression fittings be used.

The AquaFlush is designed for one lift

only and the vertical lift must be made

within 500mm of the unit.

IMPORTANT – It is recommended

that there are no bends in the vertical

lift, however if this is unavoidable a

minimum of slow radius bends may

be used.

Electrical connection

A qualified person in accordance with

the Institute Of Electrical Engineers

Regulations should connect the

unit to the appropriate mains supply

taking into account all the electrical

information provided.

IMPORTANT – All pump systems

must be used with an appropriate

motor rated protection device.

Maintenance

The AquaFlush requires minimal

maintenance. Basic common sense

and good housekeeping will ensure

the best results. It is recommended

that the unit be rinsed through with

warm water and a minimum of

bleach and washing up liquid added

(approx. every 1–2 weeks). This

should stop any milk residue and

other fatty deposits being allowed to

accumulate, go rancid and produce

bad odours.

Once or twice yearly it is

recommended that the unit be

inspected. The lid should be removed

and the tank and float cleaned.

Health & safety

As with all site work, the danger of

working with water and electricity

can pose a severe threat to

health if obvious and fundamental

precautions are not taken. Therefore

if you are in any doubt regarding

the installation, please contact us.

All site work must be undertaken by

qualified personnel only.

These notes are for guidance only

and it is for the installer to ensure

the installation is in accordance

with all structural and regulatory

requirements.

Model AquaFlush AquaFlushMF

Power Supply 230V AC 230V AC

Rated Current 2.1A 3A

Motor Rating 460W 660W

Frequency 50Hz 50Hz

Revolutions per Minute

2900rpm 2900rpm

Max. Vertical Output 6m 11m

Max. Horizontal Output

45m 80m

Horizontal Fall 1:200 1:200

Max. Flow Rate 180l/m 180l/m

Max. Liquid Temp. <60°C intermittent <60°C intermittent

Discharge Size 32mm 32mm

Cable Length 3m 3m

Weight 5.3kg 11kg

Colour White White

Model Length Width Height

AquaFlush 345mm 400mm 390mm

AquaFlushMF 345mm 400mm 390mm

DIMENSIONS

The Company reserves the right to make any alterations in the

interest of technical development.

Page 30: Product Catalogue - ESIcms.esi.info/Media/documents/Edinc_Catalog_ML.pdf · • Optimum performance of prthe pump system; • Improved environmental conditions. Our service agreements

1YEAR

One-year GuaranteeTerms and conditions apply.

ServiCe aGreementSIt is essential this product undergoes routine servicing. Please contact our service dept. for further information.

WASTE WATER PUMPING SYSTEMS30

HYDROFLUSH ™

The HydroFlush is a fully automatic

waste water pumping system suitable for

pumping waste water to a higher level

when gravity drainage is not possible or

economical to install.

The system is suitable for installing either at the

initial building stage or retro fitting to existing

buildings and can accept waste connections from

a shower or basin or similar.

The system consists of a compact odour tight unit

with a built in automatic waste water pump.

The HydroFlush is easy to install due to both

its size and the small bore (22mm) discharge

pipework required.

Page 31: Product Catalogue - ESIcms.esi.info/Media/documents/Edinc_Catalog_ML.pdf · • Optimum performance of prthe pump system; • Improved environmental conditions. Our service agreements

SPECIFICATIONSINSTALLATION gUIDELINES

31WASTE WATER PUMPING SYSTEMS

Tel 01442 211554

Fax 01442 211553

[email protected]

www.edincare.com

For prices and additional information please

contact Sales on 01442 211554

HYDROFLUSH ™Compact waste water pumping systems suitable for a shower or basin.

It is important to note that these

instructions are for guidance only.

Please refer to the full Installation

and Operating Guidelines when

specifying / installing the product.

Siting the product

The HydroFlush should be positioned

on a firm level surface, resistant to

condensation. The unit must be

located lower than the outflow of the

appliances served so as to provide a

gravity fall into the unit.

It is extremely important to site the

HydroFlush with access in mind in the

event of maintenance being required.

Inlet connections

The waste water inlet is located on

the side of the unit via the flexible

40mm rubber connector provided.

The wider end of this 40mm

connector should be connected to

the HydroFlush with the other end

to the 40mm uPVC waste pipe from

the shower or wash hand basin. The

provided plastic clips should be used

to firmly fix the inlet pipework in place.

Discharge connection

The discharge pipework should be

22mm copper or uPVC and should

be firmly fixed and rigid. An elbow

with non-return valve is supplied

with the unit for situations where

there is a need to pump vertically,

this is connected to the discharge

spigot using a jubilee clip. The non-

return valve should be fixed to the

HydroFlush using a jubilee clip. It

is very important to ensure that the

directional arrow on the non-return

valve points in the direction of the

flow, if pumping horizontally the

directional arrow should show along

the top.

All joins in the discharge line should

be made using solvent cement, under

no circumstances should push fit or

compression fittings be used.

The HydroFlush is designed for one

lift only and the vertical lift should be

within 500mm of the unit.

IMPORTANT – It is recommended

that there are no bends in the vertical

lift, however if this is unavoidable a

minimum of slow radius bends may

be used.

Electrical connection

A qualified person in accordance with

the Institute Of Electrical Engineers

Regulations should connect the

unit to the appropriate mains supply

taking into account all the electrical

information provided.

IMPORTANT – All pump systems

must be used with an appropriate

motor rated protection device.

Maintenance

The HydroFlush does not require

any particular maintenance other

than general good housekeeping.

The unit is capable of accepting

allhousehold-cleaningproducts;

however do not dispose of solvents,

acids or any other strong chemicals

via the HydroFlush.

Health & safety

As with all site work, the danger of

working with water and electricity

can pose a severe threat to

health if obvious and fundamental

precautions are not taken. Therefore

if you are in any doubt regarding

the installation, please contact us.

All site work must be undertaken by

qualified personnel only.

These notes are for guidance only

and it is for the installer to ensure

the installation is in accordance

with all structural and regulatory

requirements.

Model HydroFlush

Power Supply 230V AC

Rated Current 1.3A

Motor Rating 250W

Frequency 50Hz

Revolutions per Minute

2800rpm

Max. Vertical Output 4m

Max. Horizontal Output

25m

Horizontal Fall 1:200

Max. Flow Rate 60l/m

Max. Liquid Temp. <35°C intermittent

Discharge Size 22mm

Cable Length 1m

Weight 3.5kg

Colour White

Model Length Width Height

HydroFlush 295mm 165mm 145mm

DIMENSIONS

The Company reserves the right to make any alterations in the

interest of technical development.

Page 32: Product Catalogue - ESIcms.esi.info/Media/documents/Edinc_Catalog_ML.pdf · • Optimum performance of prthe pump system; • Improved environmental conditions. Our service agreements

1YEAR

One-year GuaranteeTerms and conditions apply.

ServiCe aGreementSIt is essential this product undergoes routine servicing. Please contact our service dept. for further information.

WASTE WATER PUMPING SYSTEMS32

SHOWERFLUSH ™

The ShowerFlush is a fully automatic

waste water pumping system suitable for

drawing and pumping waste water to a

higher level when gravity drainage is not

possible or economical to install.

The system is suitable for installing either at the

initial building stage or retro fitting to existing

buildings and can accept a waste connection from

a shower only.

The system consists of a polyethylene waterproof

case with a built in low voltage waste water

diaphragm pump. This unique system draws the

waste water from the shower tray before pumping

it to the final discharge point. The system activates

via an inline flow switch.

The ShowerFlush is easy to install due to its small

bore (22mm) discharge pipework required.

Page 33: Product Catalogue - ESIcms.esi.info/Media/documents/Edinc_Catalog_ML.pdf · • Optimum performance of prthe pump system; • Improved environmental conditions. Our service agreements

SPECIFICATIONSINSTALLATION gUIDELINES

33WASTE WATER PUMPING SYSTEMS

Tel 01442 211554

Fax 01442 211553

[email protected]

www.edincare.com

For prices and additional information please

contact Sales on 01442 211554

SHOWERFLUSH ™Waste water pumping system suitable for wet rooms and disabled showers

It is important to note that these

instructions are for guidance only.

Please refer to the full Installation

and Operating Guidelines when

specifying / installing the product.

Siting the product

The ShowerFlush is encased in

an IP55 rated case, which means

it is dustproof and splash proof.

Therefore, if necessary the unit can

be located inside the shower area.

Ideally the pump should be located

as low to the floor as possible,

no higher than 700mm above the

tray/floor and as near as practical

to the installation, which is usually

between 100mm and 1m.

It is extremely important to site the

ShowerFlush with access in mind

in the event of maintenance being

required.

Inlet connection

The ShowerFlush comes as standard

with a 15mm (½") compression fitting

for connection of a 15mm copper

pipe. It is very important that the

incoming 15mm pipework from the

shower tray has as few bends in it

as possible and any used should be

slow radius bends.

Discharge connection

The discharge line must be

connected to the ShowerFlush via

the 22mm (¾") compression fitting

which can be on either the left or

the right hand side of the unit (this

must be specified at time of order).

The discharge line must be in 22mm

copper pipework to connect to the

compression fitting.

The Showerflush is designed for one

lift only and the vertical should be

within 500mm of the unit.

IMPORTANT – It is recommended

that there are no bends in the vertical

lift, however if this is unavoidable a

minimum of slow radius bends may

be used.

Electrical connection

A qualified person in accordance with

the Institute Of Electrical Engineers

Regulations should connect the

unit to the appropriate mains supply

taking into account all the electrical

information provided.

IMPORTANT – All pump systems

must be used with an appropriate

motor rated protection device.

Maintenance

The ShowerFlush does not require

any particular maintenance other

than general good housekeeping.

The unit is capable of accepting

allhousehold-cleaningproducts;

however do not dispose of solvents,

acids or any other strong chemicals

via the ShowerFlush.

Health & safety

As with all site work, the danger of

working with water and electricity

can pose a severe threat to

health if obvious and fundamental

precautions are not taken. Therefore

if you are in any doubt regarding

the installation, please contact us.

All site work must be undertaken by

qualified personnel only.

These notes are for guidance only

and it is for the installer to ensure

the installation is in accordance

with all structural and regulatory

requirements.

Model ShowerFlush

Power Supply 230V AC

Rated Current 2.0A

Motor Rating 480W

Frequency 50Hz

Revolutions per Minute

N/A

Max. Vertical Output 3m

Max. Horizontal Output

15m

Max. Flow Rate 14l/m

Max. Liquid Temp. <40°C

Discharge Size 22mm

Cable Length None

Weight 5kg

Colour Light grey

Model Length Width Height

ShowerFlush 320mm 245mm 170mm

DIMENSIONS

The Company reserves the right to make any alterations in the

interest of technical development.

Page 34: Product Catalogue - ESIcms.esi.info/Media/documents/Edinc_Catalog_ML.pdf · • Optimum performance of prthe pump system; • Improved environmental conditions. Our service agreements

1YEAR

One-year GuaranteeTerms and conditions apply.

ServiCe aGreementSIt is essential this product undergoes routine servicing. Please contact our service dept. for further information.

WASTE WATER PUMPING SYSTEMS34

The BlueMax is a fully automatic waste

water pumping system suitable for

pumping condensate water to a higher

level when gravity drainage is not possible

or economical to install.

BLUEMAX ™

The system is suitable for installing either

at the initial building stage or retro fitting

to existing buildings and can accept waste

connections from a condensate boiler,

automatic refrigeration, steam oven or similar.

The system consists of a compact unit with a

built in automatic waste water pump.

The BlueMax is easy to install due to both

its size and the small bore (9.5mm) discharge

tube required.

Page 35: Product Catalogue - ESIcms.esi.info/Media/documents/Edinc_Catalog_ML.pdf · • Optimum performance of prthe pump system; • Improved environmental conditions. Our service agreements

SPECIFICATIONSINSTALLATION gUIDELINES

35WASTE WATER PUMPING SYSTEMS

Tel 01442 211554

Fax 01442 211553

[email protected]

www.edincare.com

For prices and additional information please

contact Sales on 01442 211554

Light weight compact condensate pump BLUEMAX ™

It is important to note that these

instructions are for guidance only.

Please refer to the full Installation

and Operating Guidelines when

specifying / installing the product.

Siting the product

The BlueMax should be located as

close to the served appliance as is

possible, though it can be located

further away as long as the appliance

can gravity drain into the unit. The

BlueMax also comes complete with

wall mounting tabs moulded onto

the unit for ease of location and

installation.

Inlet connections

The condensate/water inlets from

the served appliance are provided

pre-cut into the housing on the

top of the unit. These inlets are cut

to accept 28mm diameter pipe,

however smaller diameter pipework

can be acceptable if used with the

appropriate pipe reducer.

Discharge connection

The discharge line for the BlueMax is

connected to the 9.5mm OD barbed

discharge adaptor. Provided with the

unit is a length of 9.5mm evacuation

tubing which should be used as the

discharge pipe work. It is imperative

that the unit discharge vertically

before any horizontal run and the

pipework is firmly fixed to prevent

any twists in the 9.5mm evacuation

tube. The unit comes compete with

a removable non-return valve inside

the 9.5mm discharge adaptor.

IMPORTANT – It is recommended

that there are no bends in the vertical

lift, however if this is unavoidable a

minimum of slow radius bends may

be used.

Electrical connection

A qualified person in accordance with

the Institute Of Electrical Engineers

Regulations should connect the

unit to the appropriate mains supply

taking into account all the electrical

information provided.

IMPORTANT – All pump systems

must be used with an appropriate

motor rated protection device.

Maintenance

The BlueMax requires minimal

maintenance however it is

recommended that the collection

tank be cleaned out every 6–8 weeks

with standard domestic cleaning

products to prevent any build up of

materials which may adversely affect

the operation of the pump.

Health & safety

As with all site work, the danger of

working with water and electricity

can pose a severe threat to

health if obvious and fundamental

precautions are not taken. Therefore

if you are in any doubt regarding

the installation, please contact us.

All site work must be undertaken by

qualified personnel only.

These notes are for guidance only

and it is for the installer to ensure

the installation is in accordance

with all structural and regulatory

requirements.

Model BlueMax

Power Supply 230V AC

Rated Current 0.6A

Motor Rating 75W

Frequency 50Hz

Revolutions per Minute

2800rpm

Max. Vertical Output 4.5m

Max. Horizontal Output

10m

Max. Flow Rate 5l/m

Max. Liquid Temp. <65°C

Discharge Size 9.5mm tubing

Cable Length 1.8m

Weight 2.9kg

Colour Blue/White

Model Length Width Height

BlueMax 249mm 123mm 177mm

DIMENSIONS

The Company reserves the right to make any alterations in the

interest of technical development.

Page 36: Product Catalogue - ESIcms.esi.info/Media/documents/Edinc_Catalog_ML.pdf · • Optimum performance of prthe pump system; • Improved environmental conditions. Our service agreements

1YEAR

One-year GuaranteeTerms and conditions apply.

ServiCe aGreementSIt is essential this product undergoes routine servicing. Please contact our service dept. for further information.

WASTE WATER PUMPING SYSTEMS36

SUMPFLUSH ™

The SumpFlush is a fully automatic

waste water pumping system suitable for

pumping storm water to a higher level

when gravity drainage is not possible or

economical to install.

The system is suitable for installing either at the

initial building stage or retro fitting to existing

buildings and can accept waste from car parks,

car washes, floor areas, down pipes or similar.

The system consists of a polyethylene tank with

a built in automatic waste water submersible

pump. It can accept storm water through the

grille located on the top of the unit or through two

110mm inlets located to the side (side inlets to be

specified at time of order).

SuperSumpFlush

SumpFlush

High head SuperSumpFlush.

Standard SumpFlush.

ACCESSORIES

Access cover Additional inletsHigh level alarm

(mains)High level alarm (mains&battery)

Telemetric system

AL

AR

M

Page 37: Product Catalogue - ESIcms.esi.info/Media/documents/Edinc_Catalog_ML.pdf · • Optimum performance of prthe pump system; • Improved environmental conditions. Our service agreements

SPECIFICATIONSINSTALLATION gUIDELINES

37WASTE WATER PUMPING SYSTEMS

Tel 01442 211554

Fax 01442 211553

[email protected]

www.edincare.com

For prices and additional information please

contact Sales on 01442 211554

SUMPFLUSH ™Removes storm water from remote areas

It is important to note that these

instructions are for guidance only.

Please refer to the full Installation

and Operating Guidelines when

specifying / installing the product.

Siting the product

The SumpFlush is designed for

installation below ground so the

ground conditions should be taken

into account prior to locating the

unit. Wherever possible roadway

installations should be avoided,

however if this is not possible any

imposed loads should be also taken

into account.

It is extremely important to site the

SumpFlush with access in mind in the

event of maintenance being required.

Inlet connections

The SumpFlush comes as standard

complete with a heavy-duty

polypropylene grille which acts as the

inlet for surface water. If a rainwater

downpipe or gully is to drain into the

unit then a 110mm rubber connector

is located on the side of the tank to

accept 110mm uPVC waste pipe. The

110mm waste pipe should be pushed

into the rubber connector to form a

watertight seal around the incoming

waste pipe.

Discharge connection

The discharge line must be

connected to the SumpFlush via

the tank connector on the side of

the unit. The tank connector will

accept 32mm uPVC waste pipe. All

joins in the discharge line must be

made with solvent cement, under

no circumstances should push fit or

compression fittings be used.

The SumpFlush is designed to pump

upwards on a gradient or for one

verticalliftonly;theverticalliftmust

be within 500mm of the unit.

IMPORTANT – It is recommended

that there are no bends in the vertical

lift, however if this is unavoidable a

minimum of slow radius bends may

be used.

Electrical connection

A qualified person in accordance with

the Institute Of Electrical Engineers

Regulations should connect the

unit to the appropriate mains supply

taking into account all the electrical

information provided.

IMPORTANT – All pump systems

must be used with an appropriate

motor rated protection device.

Maintenance

The SumpFlush requires minimal

maintenance. Basic common sense

and good housekeeping will ensure

the best results. It is recommended

that the unit be inspected visually

at least once a month by lifting the

grille, with any debris (i.e. leaves,

twigs, stones etc.) being removed. At

least every six months it is advised

to check the operation of the float

switch and also clean the tank with a

minimum of bleach or other domestic

cleaning products.

Health & safety

As with all site work, the danger of

working with water and electricity

can pose a severe threat to

health if obvious and fundamental

precautions are not taken. Therefore

if you are in any doubt regarding

the installation, please contact us.

All site work must be undertaken by

qualified personnel only.

These notes are for guidance only

and it is for the installer to ensure

the installation is in accordance

with all structural and regulatory

requirements.

Model SumpFlush SuperSumpFlush

Power Supply 230V AC 230V AC

Rated Current 1.4A 3.6A

Motor Rating 320W 700W

Frequency 50Hz 50Hz

Revolutions per Minute

2720rpm 2800rpm

Max. Vertical Output 7m 12m

Max. Horizontal Output

50m 100m

Max. Flow Rate 108l/m 240l/m

Max. Liquid Temp. <40°C <40°C

Discharge Size 32mm 32mm

Cable Length 3m 3m

Weight 9kg 15kg

Colour White White

Model Diameter Height

SumpFlush 500mm 600mm

SuperSumpFlush 500mm 600mm

DIMENSIONS

The Company reserves the right to make any alterations in the

interest of technical development.

Page 38: Product Catalogue - ESIcms.esi.info/Media/documents/Edinc_Catalog_ML.pdf · • Optimum performance of prthe pump system; • Improved environmental conditions. Our service agreements

MACERATORS AND MACERATING TOILETS38

1YEAR

One-year GuaranteeTerms and conditions apply.

ServiCe aGreementSIt is essential this product undergoes routine servicing. Please contact our service dept. for further information.

POWERFLUSH ™

The PowerFlush is a fully automatic

macerator suitable for pumping waste

from a complete bathroom to a higher

level when gravity drainage is not possible

or economical to install.

The system is suitable for installing either at the

initial building stage or retro fitting to existing

buildings and can accept waste connections from

a toilet, basin, shower or bidet.

The PowerFlush incorporates the unique Piranha®

cutting system – its razor sharp stainless steel

blades act like a pair of rotary scissors to cut up

waste items, reducing the chance of a blockage.

The PowerFlush is compact and easy to install,

discharging to the right or left.

Heavy duty macerator.

PowerFlush (High Level Alarm)

PowerFlush

Heavy duty macerator with audible high

level alarm.

Page 39: Product Catalogue - ESIcms.esi.info/Media/documents/Edinc_Catalog_ML.pdf · • Optimum performance of prthe pump system; • Improved environmental conditions. Our service agreements

INSTALLATION gUIDELINES

Tel 01442 211554

Fax 01442 211553

[email protected]

www.edincare.com

For prices and additional information please

contact Sales on 01442 211554

MACERATORS AND MACERATING TOILETS 39

POWERFLUSH ™

It is important to note that these

instructions are for guidance only.

Please refer to the full Installation

and Operating Guidelines when

specifying / installing the product.

Siting the product

The unit is designed for a direct

toilet connection and so should

be positioned behind the toilet

on a firm level surface, resistant

to condensation. It is extremely

important to site the PowerFlush

with access in mind in the event of

maintenance being required.

Inlet connections

The PowerFlush comes complete

with 1no. WC pan connection and

2no. 32/40mm connections for

additional appliances. To connect

the toilet to the WC connection you

must position the toilet in front of the

unit and pull the black rubber sealing

sleeve directly onto the toilet outflow

spigot ensuring as much of the spigot

as possible is covered. To connect

additional appliances (i.e. basin,

shower, bidet etc.) there is a low level

inlet on either side of the unit. The

inlets are designed to accept 40mm

uPVC waste pipe, however if you wish

to use 32mm uPVC waste pipe there

are fittings provided to do so.

Discharge connection

The discharge line can be connected

to the PowerFlush on either the left or

the right hand side of the unit.

The non-return valve should be

connected to the discharge port

being used, using the jubilee clips

provided.

The discharge pipework should

be 32mm uPVC waste pipe and all

joins should be made using solvent

cement, under no circumstances

should push fit or compression

fittings be used.

The PowerFlush is designed for one

lift only and the vertical lift should be

within 500mm of the unit.

IMPORTANT – It is recommended

that there are no bends in the vertical

lift, however if this is unavoidable a

minimum of slow radius bends may

be used.

Electrical connection

A qualified person in accordance with

the Institute Of Electrical Engineers

Regulations should connect the

unit to the appropriate mains supply

taking into account all the electrical

information provided.

IMPORTANT – All pump systems

must be used with an appropriate

motor rated protection device.

Maintenance

It is recommended that the

PowerFlush be flushed through every

two weeks using standard domestic

bleaches, WC cleansers, etc.

IMPORTANT – The following items

must not be disposed of into the

PowerFlush:

• CottonWoolBuds,

• BabyWipes,

• Anyhardobjects,i.e.wood,

metals, plastics etc.,

• Anyfibrousmaterialssuchas

cloths, rags etc.,

• Orsimilar.

Health & safety

As with all site work, the danger of

working with water and electricity

can pose a severe threat to

health if obvious and fundamental

precautions are not taken. Therefore

if you are in any doubt regarding

the installation, please contact us.

All site work must be undertaken by

qualified personnel only.

These notes are for guidance only

and it is for the installer to ensure

the installation is in accordance

with all structural and regulatory

requirements.

Heavy duty macerator with the Piranha® cutting system

Model PowerFlush PowerFlush HLA

Power Supply 230V AC 230V AC

Rated Current 4.7A 4.7A

Motor Rating 1100W 1100W

Frequency 50Hz 50Hz

Revolutions per Minute

2900rpm 2900rpm

Max. Vertical Output 7m 7m

Max. Horizontal Output

50m 50m

Horizontal Fall 1:200 1:200

Max. Flow Rate 96l/m 96l/m

Max. Liquid Temp. <60°C intermittent <60°C intermittent

Discharge Size 32mm 32mm

Cable Length 2m 2m

Weight 9kg 9kg

Colour White White

Model Length Width Height

PowerFlush 414mm 197mm 287mm

PowerFlush H/L/A 414mm 197mm 287mm

SPECIFICATIONS

DIMENSIONS

The Company reserves the right to make any alterations in the

interest of technical development.

Page 40: Product Catalogue - ESIcms.esi.info/Media/documents/Edinc_Catalog_ML.pdf · • Optimum performance of prthe pump system; • Improved environmental conditions. Our service agreements

MACERATORS AND MACERATING TOILETS40

1YEAR

One-year GuaranteeTerms and conditions apply.

ServiCe aGreementSIt is essential this product undergoes routine servicing. Please contact our service dept. for further information.

MAXIFLUSH ™

The MaxiFlush is a fully automatic

macerator suitable for pumping waste

from a complete bathroom to a higher level

when gravity drainage is not possible or

economical to install.

The system is suitable for installing either

at the initial building stage or retro fitting

to existing buildings and can accept

waste connections from a toilet, basin,

shower or bidet.

The system offers reliable performance

due to its state of the art pump design

with serrated stainless steel blades.

The MaxiFlush is both easy to install

and maintain, due to its ‘slip over’ collar,

discharge hose and easy access lid.

Page 41: Product Catalogue - ESIcms.esi.info/Media/documents/Edinc_Catalog_ML.pdf · • Optimum performance of prthe pump system; • Improved environmental conditions. Our service agreements

SPECIFICATIONSINSTALLATION gUIDELINES

Tel 01442 211554

Fax 01442 211553

[email protected]

www.edincare.com

For prices and additional information please

contact Sales on 01442 211554

MACERATORS AND MACERATING TOILETS 41

MAXIFLUSH ™The quiet domestic macerator for a complete bathroom

It is important to note that these

instructions are for guidance only.

Please refer to the full Installation

and Operating Guidelines when

specifying / installing the product.

Siting the product

The unit is designed for a direct

toilet connection and so should

be positioned behind the toilet

on a firm level surface, resistant

to condensation. It is extremely

important to site the MaxiFlush

with access in mind in the event of

maintenance being required.

Inlet connections

The MaxiFlush comes complete with

1no. WC pan connector and 2no.

40mm connectors for additional

appliances.

To connect the toilet, push the white

WC connector into the unit and then

push the WC spigot as far into the

connector as possible.

To connect additional appliances

(i.e. basin, shower, bidet etc.) there

is a low level inlet on either side of

the unit. The inlets are designed to

accept a 40mm female threaded

fitting.

Discharge connection

Connection of the discharge pipe

should be to the flexible evacuation

pipe using 28mm uPVC waste pipe

and secured with a jubilee clip. All

joins in the discharge pipe should be

made using solvent cement, under

no circumstances should push fit or

compression fittings be used.

The MaxiFlush is designed for one

lift only and the vertical lift should be

within 500mm of the unit.

IMPORTANT – It is recommended

that there are no bends in the vertical

lift, however if this is unavoidable a

minimum of slow radius bends may

be used.

Electrical connection

A qualified person in accordance with

the Institute Of Electrical Engineers

Regulations should connect the

unit to the appropriate mains supply

taking into account all the electrical

information provided.

IMPORTANT – All pump systems

must be used with an appropriate

motor rated protection device.

Maintenance

It is recommended that the

MaxiFlush be flushed through every

two weeks using standard domestic

bleaches, WC cleansers, etc.

IMPORTANT – The following items

must not be disposed of into the

MaxiFlush:

• CottonWoolBuds,

• BabyWipes,

• Anyhardobjects,i.e.wood,

metals, plastics etc.,

• Anyfibrousmaterialssuchas

cloths, rags etc.,

• Orsimilar.

Health & safety

As with all site work, the danger of

working with water and electricity

can pose a severe threat to

health if obvious and fundamental

precautions are not taken. Therefore

if you are in any doubt regarding

the installation, please contact us.

All site work must be undertaken by

qualified personnel only.

These notes are for guidance only

and it is for the installer to ensure

the installation is in accordance

with all structural and regulatory

requirements.

Model MaxiFlush

Power Supply 230V AC

Rated Current 2.1A

Motor Rating 650W

Frequency 50Hz

Revolutions per Minute

3000rpm

Max. Vertical Output 7m

Max. Horizontal Output

50m

Horizontal Fall 1:200

Max. Flow Rate 80l/m

Max. Liquid Temp. <60°C intermittent

Discharge Size 28mm

Cable Length 1.5m

Weight 9Kg

Colour White

Model Length Width Height

MaxiFlush 485mm 200mm 270mm

DIMENSIONS

The Company reserves the right to make any alterations in the

interest of technical development.

Page 42: Product Catalogue - ESIcms.esi.info/Media/documents/Edinc_Catalog_ML.pdf · • Optimum performance of prthe pump system; • Improved environmental conditions. Our service agreements

MACERATORS AND MACERATING TOILETS42

1YEAR

One-year GuaranteeTerms and conditions apply.

ServiCe aGreementSIt is essential this product undergoes routine servicing. Please contact our service dept. for further information.

MAESTROSANISPLIT ™

The MaestroSanisplit is a fully automatic

macerator suitable for pumping waste

from a complete bathroom to a higher

level when gravity drainage is not possible

or economical to install.

The system is suitable for installing either at the

initial building stage or retro fitting to existing

buildings and can accept waste connections from

a toilet, basin, shower or bidet.

The system is ideal for commercial applications

such as hotels and guesthouses, as standard

domestic macerators are prone to blockages

due to abuse leading to loss of revenue. The

MaestroSanisplit consists of two modules, the

collection tank and detachable pump module.

Should a blockage occur the pump module can be

removed for servicing and immediately replaced

with a spare. This means that within minutes the

system is fully operational.

ACCESSORIES

Spare pump module

Standard MaestroSanisplit macerator.

MaestroSanisplitPro

MaestroSanisplit

High head MaestroSanisplit macerator.

Page 43: Product Catalogue - ESIcms.esi.info/Media/documents/Edinc_Catalog_ML.pdf · • Optimum performance of prthe pump system; • Improved environmental conditions. Our service agreements

SPECIFICATIONSINSTALLATION gUIDELINES

Tel 01442 211554

Fax 01442 211553

[email protected]

www.edincare.com

For prices and additional information please

contact Sales on 01442 211554

MACERATORS AND MACERATING TOILETS 43

MAESTROSANISPLIT ™Compact design and easy to maintain

It is important to note that these

instructions are for guidance only.

Please refer to the full Installation

and Operating Guidelines when

specifying / installing the product.

Siting the product

The unit is designed for a direct

toilet connection and so should

be positioned behind the toilet

on a firm level surface, resistant

to condensation. It is extremely

important to site the MaestroSanisplit

with access in mind in the event of

maintenance being required.

Inlet connections

The MaestroSanisplit comes

complete with 1no. WC pan

connection and 2no. 32/40mm

connections for additional appliances.

To connect the toilet to the WC

connection you must position the

toilet in front of the unit and pull the

black rubber sealing sleeve directly

onto the toilet outflow spigot and

securing it in place using the 100mm

jubilee clip provided.

To connect additional appliances (i.e.

basin, shower, bidet etc.) there are

two inlets to the rear of the unit which

accept 32mm or 40mm uPVC waste

pipe which should be secured in

place using the jubilee clips provided.

Discharge connection

The discharge line must be

connected to the top rubber

connector at the rear of the unit using

32mm uPVC waste pipe and fixed

into place using a jubilee clip.

All joins in the discharge line must be

made using solvent cement, under

no circumstances should push fit or

compression fittings be used.

The MaestroSanisplit is designed for

one lift only and the vertical lift should

be within 500mm of the unit.

IMPORTANT – It is recommended

that there are no bends in the vertical

lift, however if this is unavoidable a

minimum of slow radius bends may

be used.

Electrical connection

A qualified person in accordance with

the Institute Of Electrical Engineers

Regulations should connect the

unit to the appropriate mains supply

taking into account all the electrical

information provided.

IMPORTANT – All pump systems

must be used with an appropriate

motor rated protection device.

Maintenance

It is recommended that the

MaestroSanisplit be flushed through

every two weeks using standard

domestic bleaches, WC cleansers,

etc.

IMPORTANT – The following items

must not be disposed of into the

MaestroSanisplit:

• CottonWoolBuds,

• BabyWipes,

• Anyhardobjects,i.e.wood,

metals, plastics etc.,

• Anyfibrousmaterialssuchas

cloths, rags etc.,

• Orsimilar.

Health & safety

As with all site work, the danger of

working with water and electricity

can pose a severe threat to

health if obvious and fundamental

precautions are not taken. Therefore

if you are in any doubt regarding

the installation, please contact us.

All site work must be undertaken by

qualified personnel only.

These notes are for guidance only

and it is for the installer to ensure

the installation is in accordance

with all structural and regulatory

requirements.

Model MaestroSanisplit MaestroSanisplitPro

Power Supply 230V AC 230V AC

Rated Current 3A 3A

Motor Rating 600W 1000W

Frequency 50Hz 50Hz

Revolutions per Minute

2700rpm 2700rpm

Max. Vertical Output

7m 11m

Max. Horizontal Output

50m 80m

Horizontal Fall 1:200 1:200

Max. Flow Rate 135l/m 175l/m

Max. Liquid Temp.

<60°C intermittent <60°C intermittent

Discharge Size 32mm 32mm

Cable Length 1.2m 1.2m

Weight 10kg 10kg

Colour White White

Model Length Width Height

MaestroSanisplit 450mm 175mm 270mm

MaestroSanisplitPro 450mm 175mm 270mm

DIMENSIONS

The Company reserves the right to make any alterations in the

interest of technical development.

Page 44: Product Catalogue - ESIcms.esi.info/Media/documents/Edinc_Catalog_ML.pdf · • Optimum performance of prthe pump system; • Improved environmental conditions. Our service agreements

MACERATORS AND MACERATING TOILETS44

1YEAR

One-year GuaranteeTerms and conditions apply.

ServiCe aGreementSIt is essential this product undergoes routine servicing. Please contact our service dept. for further information.

REMOTA ™

The Remota is a fully automatic floor

mounted pumping system suitable for

pumping waste from a complete bathroom

to a higher level when gravity drainage is

not possible or economical to install.

The system is suitable for installing either at the

initial building stage or retro fitting to existing

buildings and can accept waste connections from

a toilet, basin, shower or bidet.

The system does not need to be connected

directly onto the toilet and as so is ideal for remote

installation (indoors only) therefore the system can

be concealed out of sight. The system is highly

reliable and easy to maintain due to its clip on lid.

30 litre storage capacity.

Remota90

Remota30

90 litre storage capacity.

ACCESSORIES

High level alarm(mains)

High level alarm (mains&battery) Telemetric system

AL

AR

M

Page 45: Product Catalogue - ESIcms.esi.info/Media/documents/Edinc_Catalog_ML.pdf · • Optimum performance of prthe pump system; • Improved environmental conditions. Our service agreements

SPECIFICATIONSINSTALLATION gUIDELINES

Tel 01442 211554

Fax 01442 211553

[email protected]

www.edincare.com

For prices and additional information please

contact Sales on 01442 211554

MACERATORS AND MACERATING TOILETS 45

REMOTA™A fully automatic small bore sewage pumping system

It is important to note that these

instructions are for guidance only.

Please refer to the full Installation

and Operating Guidelines when

specifying / installing the product.

Siting the Product

The Remota does not need to be

connected directly onto the WC

pan and so can be sited away from

the appliances served. The Remota

should be located on a firm level

surface lower than the outflow

spigot of the WC so as to provide a

gravity fall into the unit. It is extremely

important to site the Remota with

access in mind in the event of

maintenance being required.

Inlet connections

The Remota comes complete with

1no. 110mm inlet to accept standard

soil pipe and 1no. 32mm inlet to

accept 32mm waste pipe.

To connect to the Remota from the

WC a 110mm soil pipe must be run

with sufficient gradient to gravity drain

into the unit and pushed into place

using the 110mm rubber connector

provided.

To connect additional appliances (i.e.

basin, shower, bidet etc.) there is a

32mm inlet on the lid of the Remota

or alternatively you can plumb the

waste pipe from the appliances

directly into the incoming 110mm soil

pipe using an appropriate fitting.

Discharge connection

The discharge line should be

connected to the tank connector on

the side of the unit. The pipework

required to connect to the Remota 30

should be 32mm uPVC waste pipe

and to connect to the Remota 90 it

should be 1½" PVC Class E pressure

pipe.

All joins in the discharge pipework

should be made using solvent

cement, under no circumstances

should push fit or compression

fittings be used.

The Remota is designed for one lift

only and the vertical lift should be

within 500mm of the unit.

IMPORTANT – It is recommended

that there are no bends in the vertical

lift, however if this is unavoidable a

minimum of slow radius bends may

be used.

Electrical connection

A qualified person in accordance with

the Institute Of Electrical Engineers

Regulations should connect the

unit to the appropriate mains supply

taking into account all the electrical

information provided.

IMPORTANT – All pump systems

must be used with an appropriate

motor rated protection device.

Maintenance

It is recommended that the Remota

be flushed through every two weeks

using standard domestic bleaches,

WC cleansers, etc.

IMPORTANT – The following items

must not be disposed of into the

Remota:

• CottonWoolBuds,

• BabyWipes,

• Anyhardobjects,i.e.wood,

metals, plastics etc.,

• Anyfibrousmaterialssuchas

cloths, rags etc.,

• Orsimilar.

Health & safety

As with all site work, the danger of

working with water and electricity

can pose a severe threat to

health if obvious and fundamental

precautions are not taken. Therefore

if you are in any doubt regarding the

installation, please contact us.

All site work must be undertaken by

qualified personnel only.

These notes are for guidance only

and it is for the installer to ensure

the installation is in accordance

with all structural and regulatory

requirements.

Model Remota30 Remota90

Power Supply 230V AC 230V AC

Rated Current 1.4A 1.9A

Motor Rating 150W 250W

Frequency 50Hz 50Hz

Revolutions per Minute

3000rpm 3000rpm

Max. Vertical Output 7m 8m

Max. Horizontal Output

50m 70m

Horizontal Fall 1:200 1:200

Max. Flow Rate 120l/m 180l/m

Max. Liquid Temp. <40°C <40°C

Discharge Size 32mm 1½"

Cable Length 10m 10m

Weight 11.5kg 15.5kg

Colour White White

Float Level (On) 250mm 330mm

Float Level (Off) 100mm 125mm

Model Length Width Height

Remota30 400mm 300mm 350mm

Remota90 600mm 400mm 450mm

DIMENSIONS

The Company reserves the right to make any alterations in the

interest of technical development.

Page 46: Product Catalogue - ESIcms.esi.info/Media/documents/Edinc_Catalog_ML.pdf · • Optimum performance of prthe pump system; • Improved environmental conditions. Our service agreements

MACERATORS AND MACERATING TOILETS46

1YEAR

One-year GuaranteeTerms and conditions apply.

ServiCe aGreementSIt is essential this product undergoes routine servicing. Please contact our service dept. for further information.

SUPERFLUSH ™

The SuperFlush is a fully automatic

chinaware toilet macerator suitable for

pumping waste from the WC pan to a

higher level when gravity drainage is not

possible or economical to install.

The system is suitable for installing either at the

initial building stage or retro fitting to existing

buildings, it cannot accept waste connections

from any other appliances.

The system consists of a chinaware WC pan with

a built in macerator. No cistern is required as the

unit is connected directly to a cold water supply

enabling a space saving ‘back to wall’ installation.

The SuperFlush is easy to install as the discharge

pipework can be positioned in any direction.

SUPERFLUSH 1000

Standard classic design.

SuperFlush2002

SuperFlush1000

Modern design ideal for space saving

applications.

SUPERFLUSH 2002

Page 47: Product Catalogue - ESIcms.esi.info/Media/documents/Edinc_Catalog_ML.pdf · • Optimum performance of prthe pump system; • Improved environmental conditions. Our service agreements

SPECIFICATIONSINSTALLATION gUIDELINES

Tel 01442 211554

Fax 01442 211553

[email protected]

www.edincare.com

For prices and additional information please

contact Sales on 01442 211554

MACERATORS AND MACERATING TOILETS 47

SUPERFLUSH ™A quiet space saving macerating toilet

It is important to note that these

instructions are for guidance only.

Please refer to the full Installation

and Operating Guidelines when

specifying / installing the product.

Siting the product

The SuperFlush has been designed

to be installed without the need for

a cistern and as long as the unit is

connected directly to a cold water

supply it can be located anywhere.

It is recommended that the unit be

placed onto a firm level surface,

resistant to condensation and fixed to

the floor using 3" No.12 Brass screws.

Discharge connection

The SuperFlush can discharge to

either the left or the right hand side of

the unit, this is achieved by loosening

the jubilee clip on the PVC elbow to

the rear of the unit and positioning it

appropriately. Once the direction of

the discharge line is in position the

soft plastic tube should be fixed into

position over the PVC elbow and

secured into place using a jubilee clip.

The discharge pipework must be

32mm uPVC waste pipe and all

joins should be made using solvent

cement, under no circumstances

should push fit or compression

fittings be used.

The SuperFlush is designed for one

vertical lift only and this lift should

be within 500mm of the unit. It is

advised that when pumping vertically

an appropriate non-return valve

(not supplied) is installed to prevent

backflow into the unit.

IMPORTANT – It is recommended

that there are no bends in the vertical

lift, however if this is unavoidable a

minimum of slow radius bends may

be used.

Electrical connection

A qualified person in accordance with

the Institute Of Electrical Engineers

Regulations should connect the

unit to the appropriate mains supply

taking into account all the electrical

information provided.

IMPORTANT – All pump systems

must be used with an appropriate

motor rated protection device.

Maintenance

It is recommended that the

SuperFlush be flushed through every

two weeks using standard domestic

bleaches, WC cleansers, etc.

IMPORTANT – The following items

must not be disposed of into the

SuperFlush:

• CottonWoolBuds,

• BabyWipes,

• Anyhardobjects,i.e.wood,

metals, plastics etc.,

• Anyfibrousmaterialssuchas

cloths, rags etc.

• Orsimilar.

Health & safety

As with all site work, the danger of

working with water and electricity

can pose a severe threat to

health if obvious and fundamental

precautions are not taken. Therefore

if you are in any doubt regarding

the installation, please contact us.

All site work must be undertaken by

qualified personnel only.

These notes are for guidance only

and it is for the installer to ensure

the installation is in accordance

with all structural and regulatory

requirements.

Model SuperFlush1000 SuperFlush2002

Power Supply 230V AC 230V AC

Rated Current 2.8A 2.8A

Motor Rating 450W 450W

Frequency 50Hz 50Hz

Revolutions per Minute

2700rpm 2700rpm

Max. Vertical Output 5m 5m

Max. Horizontal Output

30m 30m

Horizontal Fall 1:200 1:200

Max. Flow Rate 270l/m 270l/m

Max. Liquid Temp. <40°C <40°C

Discharge Size 32mm 32mm

Cable Length 1m 1m

Weight 30kg 34kg

Colour WhiteWhite/Villeroy&Boch colours

Min. Water Pressure 1.5 bar 0.3 bar

Max. Water Pressure 3 bar 3 bar

Model Length Width Height

SuperFlush1000 510mm 340mm 440mm

SuperFlush2002 490mm 345mm 435mm

DIMENSIONS

The Company reserves the right to make any alterations in the

interest of technical development.

Page 48: Product Catalogue - ESIcms.esi.info/Media/documents/Edinc_Catalog_ML.pdf · • Optimum performance of prthe pump system; • Improved environmental conditions. Our service agreements

1YEAR

One-year GuaranteeTerms and conditions apply.

ServiCe aGreementSIt is essential this product undergoes routine servicing. Please contact our service dept. for further information.

FLOOR MOUNTED PUMPING STATIONS48

GOLIATH110 ™

The goliath110 is a fully automatic floor

mounted pumping station suitable for

pumping both foul and storm water to a

higher level when gravity drainage is not

possible or economical to install.

The system is suitable for installing either at the initial

building stage or retro fitting to existing

buildings and can accept waste from a

bathroom, changing room, commercial

premises or similar.

The system consists of a polyethylene

tank, control panel with a built in

automatic vortex pump.

The Goliath110 is easy to

install, as there are a number

of inlets at varying levels/sizes

available (inlets to be cut

onsite).

ACCESSORIES

Gate valveHand membrane

pump Microvent kit

Page 49: Product Catalogue - ESIcms.esi.info/Media/documents/Edinc_Catalog_ML.pdf · • Optimum performance of prthe pump system; • Improved environmental conditions. Our service agreements

SPECIFICATIONSINSTALLATION gUIDELINES

49FLOOR MOUNTED PUMPING STATIONS

Tel 01442 211554

Fax 01442 211553

[email protected]

www.edincare.com

For prices and additional information please

contact Sales on 01442 211554

Single pump, floor mounted pumping station GOLIATH110™

It is important to note that these

instructions are for guidance only.

Please refer to the full Installation

and Operating Guidelines when

specifying / installing the product.

Siting the product

The Goliath110 should be positioned

on a firm level surface, resistant to

condensation. The unit must be

located lower than the outflow of the

appliances served so as to provide a

gravity fall into the unit.

It is extremely important to site the

Goliath110 with access in mind in the

event of maintenance being required.

Inlet connections

The Goliath110 comes with a variety

of pre-moulded inlets to accept

incoming pipework ranging from

40mm to 100mm. To utilise the inlets

you must open up the moulded inlet

by sawing the end off, leaving enough

of the mould to act as a support area

for a push-on sleeve. The incoming

pipework must then be pushed into

the push on sleeve and fixed securely

in place using an appropriate jubilee

clip.

Discharge connection

The discharge line of the Goliath110

should be 3" PVC Class E pressure

pipe. To connect to the discharge

line an appropriately sized PN16

Gate valve (not supplied, see

accessories) must be fixed directly on

the discharge spigot located on the

top of the unit. A PN16 PVC spigot

is supplied with the unit, which then

needs to be fixed to the gate valve

with the rubber connection sleeve

secured to the spigot using the jubilee

clips provided. Now you can push

your discharge pipe into the rubber

connection sleeve and once again

secure with the jubilee clips provided.

The Goliath110 is designed for one

lift only and the vertical lift should be

made before any horizontal run.

IMPORTANT – It is recommended

that there are no bends in the

vertical lift, however should this be

unavoidable a minimum of slow

radius bends may be used.

Electrical connection

A qualified person in accordance with

the Institute Of Electrical Engineers

Regulations should connect the

unit to the appropriate mains supply

taking into account all the electrical

information provided.

IMPORTANT – All pump systems

must be used with an appropriate

motor rated protection device.

Maintenance

The Goliath110 requires minimal

maintenance. It is advised that the

unit is visually inspected and its

functioning checked monthly. Also

the unit should be rinsed through

with warm water and a minimum of

bleach or other appropriate cleaning

product every 2–3 weeks to assist in

breaking down any solids that may

accumulate within the chamber.

NOTE – It is recommended that a

service agreement be taken out with

a technically qualified company.

Health & safety

As with all site work, the danger of

working with water and electricity

can pose a severe threat to

health if obvious and fundamental

precautions are not taken. Therefore

if you are in any doubt regarding

the installation, please contact us.

All site work must be undertaken by

qualified personnel only.

These notes are for guidance only

and it is for the installer to ensure

the installation is in accordance

with all structural and regulatory

requirements.

Model goliath110

Power Supply 230V AC / 400V AC

Rated Current 8.4A / 5.2A

Motor Rating 1300W / 2200W

Frequency 50Hz / 50Hz

Revolutions per Minute

1450rpm / 1450rpm

Max. Vertical Output 7m / 9.5m

Max. Horizontal Output

70m / 90m

Max. Flow Rate 750l/m / 900l/m

Max. Liquid Temp. <40°C / <40°C

Discharge Size 80mm / 80mm

Cable Length 4m / 4m

Weight 55kg / 57kg

Colour White / White

Model Length Width Height

Goliath110 800mm 500mm 423mm

DIMENSIONS

The Company reserves the right to make any alterations in the

interest of technical development.

Page 50: Product Catalogue - ESIcms.esi.info/Media/documents/Edinc_Catalog_ML.pdf · • Optimum performance of prthe pump system; • Improved environmental conditions. Our service agreements

1YEAR

One-year GuaranteeTerms and conditions apply.

ServiCe aGreementSIt is essential this product undergoes routine servicing. Please contact our service dept. for further information.

FLOOR MOUNTED PUMPING STATIONS50

The Atlas110Twin is a fully automatic floor

mounted twin pumping station suitable

for pumping both foul and storm water to

a higher level when gravity drainage is not

possible or economical to install.

The system is suitable for installing either at the

initial building stage or retro fitting to existing

buildings and can accept waste from a

bathroom, changing room, commercial

premises or similar.

The system consists of a polyethylene tank,

control panel with two built in automatic

vortex pumps.

The Atlas110Twin is easy to

install, as there are a number

of inlets at varying levels/sizes

available (inlets to be cut onsite).

ACCESSORIES

Gate valveHand membrane

pump

ATLAS110TWIN ™

Microvent kit

Page 51: Product Catalogue - ESIcms.esi.info/Media/documents/Edinc_Catalog_ML.pdf · • Optimum performance of prthe pump system; • Improved environmental conditions. Our service agreements

SPECIFICATIONSINSTALLATION gUIDELINES

51FLOOR MOUNTED PUMPING STATIONS

Tel 01442 211554

Fax 01442 211553

[email protected]

www.edincare.com

For prices and additional information please

contact Sales on 01442 211554

Twin pump, floor mounted pumping station

It is important to note that these

instructions are for guidance only.

Please refer to the full Installation

and Operating Guidelines when

specifying / installing the product.

Siting the product

The Atlas110Twin should be

positioned on a firm level surface,

resistant to condensation. The unit

must be located lower than the

outflow of the appliances served so as

to provide a gravity fall into the unit.

It is extremely important to site the

Atlas110Twin with access in mind

in the event of maintenance being

required.

Inlet connections

The Atlas110Twin comes with a

variety of pre-moulded inlets to

accept incoming pipework ranging

from 40mm to 150mm. To utilise the

inlets you must open up the moulded

inlet by sawing the end off, leaving

enough of the mould to act as a

support area for a push-on sleeve.

The incoming pipework must then

be pushed into the push on sleeve

and fixed securely in place using an

appropriate jubilee clip.

Discharge connection

The discharge line of the Atlas110Twin

should be 3" PVC Class E pressure

pipe. To connect to the discharge

line an appropriately sized PN16

Gate valve (not supplied, see

accessories) must be fixed directly on

the discharge spigot located on the

top of the unit. A PN16 PVC spigot

is supplied with the unit, which then

needs to be fixed to the gate valve

with the rubber connection sleeve

secured to the spigot using the jubilee

clips provided. Now you can push

your discharge pipe into the rubber

connection sleeve and once again

secure with the jubilee clips provided.

The Atlas110Twin is designed for one

lift only and the vertical lift should be

made before any horizontal run.

IMPORTANT – It is recommended

that there are no bends in the

vertical lift, however should this be

unavoidable a minimum of slow

radius bends may be used.

Electrical connection

A qualified person in accordance with

the Institute Of Electrical Engineers

Regulations should connect the

unit to the appropriate mains supply

taking into account all the electrical

information provided.

IMPORTANT – All pump systems

must be used with an appropriate

motor rated protection device.

Maintenance

The Atlas110Twin requires minimal

maintenance. It is advised that the

unit is visually inspected and its

functioning checked monthly. Also

the unit should be rinsed through

with warm water and a minimum of

bleach or other appropriate cleaning

product every 2–3 weeks to assist in

breaking down any solids that may

accumulate within the chamber.

NOTE – It is recommended that a

service agreement be taken out with

a technically qualified company.

Health & safety

As with all site work, the danger of

working with water and electricity

can pose a severe threat to

health if obvious and fundamental

precautions are not taken. Therefore

if you are in any doubt regarding

the installation, please contact us.

All site work must be undertaken by

qualified personnel only.

These notes are for guidance only

and it is for the installer to ensure

the installation is in accordance

with all structural and regulatory

requirements.

Model Atlas110Twin

Power Supply 230V AC / 400V AC

Rated Current 7.8A / 5.2A

Motor Rating 1700W / 2200W

Frequency 50Hz / 50Hz

Revolutions per Minute

2800rpm / 1450rpm

Max. Vertical Output 10m / 9.5m

Max. Horizontal Output

90m / 90m

Max. Flow Rate 660l/m / 900l/m

Max. Liquid Temp. <40°C / <40°C

Discharge Size 80mm / 80mm

Cable Length 4m / 4m

Weight 115kg / 117kg

Colour White / White

DIMENSIONS

ATLAS110TWIN ™

The Company reserves the right to make any alterations in the

interest of technical development.

Model Length Width Height

Atlas110Twin 965mm 790mm 561mm

Page 52: Product Catalogue - ESIcms.esi.info/Media/documents/Edinc_Catalog_ML.pdf · • Optimum performance of prthe pump system; • Improved environmental conditions. Our service agreements

1YEAR

One-year GuaranteeTerms and conditions apply.

ServiCe aGreementSIt is essential this product undergoes routine servicing. Please contact our service dept. for further information.

FLOOR MOUNTED PUMPING STATIONS52

ATLAS1702 ™

The Atlas1702 is a fully automatic floor

mounted twin pumping station suitable

for pumping both foul and storm water to

a higher level when gravity drainage is not

possible or economical to install.

The system is suitable for installing either at the

initial building stage or retro fitting to existing

buildings and can accept waste from a bathroom,

changing room, commercial premises or similar.

The system consists of a

polyethylene tank, control

panel with two built in

automatic vortex pump.

The Atlas1702 is easy

to install, as there are a

number of inlets at varying

levels/sizes available (inlets

to be cut onsite).

ACCESSORIES

Gate valveHand membrane

pump

Atlas1702HighPower

Atlas1702

High head Atlas1702.

Standard Atlas1702.

Microvent kit

Page 53: Product Catalogue - ESIcms.esi.info/Media/documents/Edinc_Catalog_ML.pdf · • Optimum performance of prthe pump system; • Improved environmental conditions. Our service agreements

SPECIFICATIONSINSTALLATION gUIDELINES

53FLOOR MOUNTED PUMPING STATIONS

Tel 01442 211554

Fax 01442 211553

[email protected]

www.edincare.com

For prices and additional information please

contact Sales on 01442 211554

ATLAS1702™Powerful twin pump, floor mounted pumping station

It is important to note that these

instructions are for guidance only.

Please refer to the full Installation

and Operating Guidelines when

specifying / installing the product.

Siting the product

The Atlas1702 should be positioned

on a firm level surface, resistant to

condensation. The unit must be

located lower than the outflow of the

appliances served so as to provide a

gravity fall into the unit.

It is extremely important to site the

Atlas1702 with access in mind in the

event of maintenance being required.

Inlet connections

The Atlas1702 comes with a variety

of pre-moulded inlets to accept

incoming pipework ranging from

40mm to 100mm. To utilise the inlets

you must open up the moulded inlet

by sawing the end off, leaving enough

of the mould to act as a support area

for a push-on sleeve. The incoming

pipework must then be pushed into

the push on sleeve and fixed securely

in place using an appropriate jubilee

clip.

Discharge connection

The discharge line of the Atlas1702

should be 3" PVC Class E pressure

pipe. To connect to the discharge

line an appropriately sized PN16

Gate valve (not supplied, see

accessories) must be fixed directly on

the discharge spigot located on the

top of the unit. A PN16 PVC spigot

is supplied with the unit, which then

needs to be fixed to the gate valve

with the rubber connection sleeve

secured to the spigot using the jubilee

clips provided. Now you can push

your discharge pipe into the rubber

connection sleeve and once again

secure with the jubilee clips provided.

The Atlas1702 is designed for one

lift only and the vertical lift should be

made before any horizontal run.

IMPORTANT – It is recommended

that there are no bends in the

vertical lift, however should this be

unavoidable a minimum of slow

radius bends may be used.

Electrical connection

A qualified person in accordance with

the Institute Of Electrical Engineers

Regulations should connect the

unit to the appropriate mains supply

taking into account all the electrical

information provided.

IMPORTANT – All pump systems

must be used with an appropriate

motor rated protection device.

Maintenance

The Atlas1702 requires minimal

maintenance. It is advised that the

unit is visually inspected and its

functioning checked monthly. Also

the unit should be rinsed through

with warm water and a minimum of

bleach or other appropriate cleaning

product every 2–3 weeks to assist in

breaking down any solids that may

accumulate within the chamber.

NOTE – It is recommended that a

service agreement be taken out with

a technically qualified company.

Health & safety

As with all site work, the danger of

working with water and electricity

can pose a severe threat to

health if obvious and fundamental

precautions are not taken. Therefore

if you are in any doubt regarding

the installation, please contact us.

All site work must be undertaken by

qualified personnel only.

These notes are for guidance only

and it is for the installer to ensure

the installation is in accordance

with all structural and regulatory

requirements.

Model Atlas1702 Atlas1702HighPower

Power Supply 400V AC 400V AC

Rated Current 3.3A 4.0A

Motor Rating 1700W 2300W

Frequency 50Hz 50Hz

Revolutions per Minute

2900rpm 2900rpm

Max. Vertical Output 13m 17m

Max. Horizontal Output

150m 200m

Max. Flow Rate 840l/m 1020l/m

Max. Liquid Temp. <40°C <40°C

Discharge Size 80mm 80mm

Cable Length 4m 4m

Weight 130kg 130kg

Colour White White

Model Length Width Height

Atlas1702 1160mm 792mm 533mm

Atlas1702HighPower 1160mm 792mm 533mm

DIMENSIONS

The Company reserves the right to make any alterations in the

interest of technical development.

Page 54: Product Catalogue - ESIcms.esi.info/Media/documents/Edinc_Catalog_ML.pdf · • Optimum performance of prthe pump system; • Improved environmental conditions. Our service agreements

1YEAR

One-year GuaranteeTerms and conditions apply.

ServiCe aGreementSIt is essential this product undergoes routine servicing. Please contact our service dept. for further information.

FLOOR MOUNTED PUMPING STATIONS54

POWERMASTER ™

The PowerMaster™ is a fully automatic small bore

macerating floor mounted pumping station suitable

for pumping both foul and waste water to a higher

level when gravity drainage is not possible or

economical to install.

The system is suitable for installing either at the initial

building stage or retro fitting to existing buildings and

can accept waste from a bathroom, changing room,

commercial premises or similar.

The system consists of a polyethylene tank, control

panel with a built in automatic macerating pump.

The PowerMaster™ is easy to install, as there are

a number of inlets at varying levels/sizes available

(inlets to be cut onsite).

ACCESSORIES

Gate valveHand membrane

pump Microvent kit

Page 55: Product Catalogue - ESIcms.esi.info/Media/documents/Edinc_Catalog_ML.pdf · • Optimum performance of prthe pump system; • Improved environmental conditions. Our service agreements

SPECIFICATIONSINSTALLATION gUIDELINES

55FLOOR MOUNTED PUMPING STATIONS

Tel 01442 211554

Fax 01442 211553

[email protected]

www.edincare.com

For prices and additional information please

contact Sales on 01442 211554

Single pump, floor mounted pumping station POWERMASTER ™

It is important to note that these

instructions are for guidance only.

Please refer to the full Installation

and Operating Guidelines when

specifying / installing the product.

Siting the product

The PowerMaster should be

positioned on a firm level surface,

resistant to condensation. The unit

must be located lower than the

outflow of the appliances served so

as to provide a gravity fall into the

unit.

It is extremely important to site the

PowerMaster with access in mind

in the event of maintenance being

required.

Inlet connections

The PowerMaster comes with a

variety of pre-moulded inlets to

accept incoming pipework ranging

from 40mm to 100mm. To utilise the

inlets you must open up the moulded

inlet by sawing the end off, leaving

enough of the mould to act as a

support area for a push-on sleeve.

The incoming pipework must then

be pushed into the push on sleeve

and fixed securely in place using an

appropriate jubilee clip.

Discharge connection

The discharge line of the

PowerMaster should be 32mm PVC

Class E pressure pipe. To connect to

the discharge line an appropriately

sized Gate valve (not supplied, see

accessories) must be fixed directly

on the discharge point located on the

side of the pump.

The PowerMaster is designed for one

lift only and the vertical lift should be

made before any horizontal run.

IMPORTANT – It is recommended

that there are no bends in the

vertical lift, however should this be

unavoidable a minimum of slow

radius bends may be used.

Electrical connection

A qualified person in accordance with

the Institute Of Electrical Engineers

Regulations should connect the

unit to the appropriate mains supply

taking into account all the electrical

information provided.

IMPORTANT – All pump systems

must be used with an appropriate

motor rated protection device.

Maintenance

The PowerMaster requires minimal

maintenance. It is advised that the

unit is visually inspected and its

functioning checked monthly. Also

the unit should be rinsed through

with warm water and a minimum of

bleach or other appropriate cleaning

product every 2–3 weeks to assist in

breaking down any solids that may

accumulate within the chamber.

NOTE – It is recommended that a

service agreement be taken out with

technically qualified company.

Health & safety

As with all site work, the danger of

working with water and electricity

can pose a severe threat to

health if obvious and fundamental

precautions are not taken. Therefore

if you are in any doubt regarding the

installation, please contact us.

All site work must be undertaken by

qualified personnel only.

These notes are for guidance only

and it is for the installer to ensure

the installation is in accordance

with all structural and regulatory

requirements.

Model PowerMaster

Power Supply 230V AC / 400V AC

Rated Current 7.8A / 4.0A

Motor Rating 1700W / 1700W

Frequency 50Hz / 50Hz

Revolutions per Minute

2900rpm / 2900rpm

Max. Vertical Output 23m / 31m

Max. Horizontal Output

260m / 350m

Max. Flow Rate 135l/m / 153l/m

Max. Liquid Temp. <40°C / <40°C

Discharge Size 1¼" / 1¼"

Cable Length 4m / 4m

Weight 58kg / 58kg

Colour White

DIMENSIONS

The Company reserves the right to make any alterations in the

interest of technical development.

Model Length Width Height

PowerMaster 875mm 570mm 485mm

Page 56: Product Catalogue - ESIcms.esi.info/Media/documents/Edinc_Catalog_ML.pdf · • Optimum performance of prthe pump system; • Improved environmental conditions. Our service agreements

1YEAR

One-year GuaranteeTerms and conditions apply.

ServiCe aGreementSIt is essential this product undergoes routine servicing. Please contact our service dept. for further information.

FLOOR MOUNTED PUMPING STATIONS56

POWERMASTERTWIN ™

The PowerMasterTwin™ is a fully automatic small

bore macerating floor mounted twin pumping

station suitable for pumping both foul and waste

water to a higher level when gravity drainage is not

possible or economical to install.

The system is suitable for installing either at the initial

building stage or retro fitting to existing buildings and

can accept waste from a bathroom, changing room,

commercial premises or similar.

The system consists of a polyethylene tank,

control panel with two built in automatic

macerating pumps.

The PowerMasterTwin™ is easy

to install, as there are a number

of inlets at varying levels/sizes

available (inlets to be cut onsite).

ACCESSORIES

Gate valveHand membrane

pump Microvent kit

Page 57: Product Catalogue - ESIcms.esi.info/Media/documents/Edinc_Catalog_ML.pdf · • Optimum performance of prthe pump system; • Improved environmental conditions. Our service agreements

SPECIFICATIONSINSTALLATION gUIDELINES

57FLOOR MOUNTED PUMPING STATIONS

Tel 01442 211554

Fax 01442 211553

[email protected]

www.edincare.com

For prices and additional information please

contact Sales on 01442 211554

Twin pump, floor mounted pumping station POWERMASTERTWIN ™

It is important to note that these

instructions are for guidance only.

Please refer to the full Installation

and Operating Guidelines when

specifying / installing the product.

Siting the product

The PowerMasterTwin should be

positioned on a firm level surface,

resistant to condensation. The unit

must be located lower than the

outflow of the appliances served so

as to provide a gravity fall into the

unit.

It is extremely important to site the

PowerMasterTwin with access in mind

in the event of maintenance being

required.

Inlet connections

The PowerMasterTwin comes with

a variety of pre-moulded inlets to

accept incoming pipework ranging

from 40mm to 150mm. To utilise the

inlets you must open up the moulded

inlet by sawing the end off, leaving

enough of the mould to act as a

support area for a push-on sleeve.

The incoming pipework must then

be pushed into the push on sleeve

and fixed securely in place using an

appropriate jubilee clip.

Discharge connection

The discharge line of the

PowerMasterTwin should be 32mm

PVC Class E pressure pipe. To

connect to the discharge line an

appropriately sized Gate valve (not

supplied, see accessories) must be

fixed directly on the discharge point

located on the side of the pumps.

The PowerMasterTwin is designed for

one lift only and the vertical lift should

be made before any horizontal run.

IMPORTANT – It is recommended

that there are no bends in the

vertical lift, however should this be

unavoidable a minimum of slow

radius bends may be used.

Electrical connection

A qualified person in accordance with

the Institute Of Electrical Engineers

Regulations should connect the

unit to the appropriate mains supply

taking into account all the electrical

information provided.

IMPORTANT – All pump systems

must be used with an appropriate

motor rated protection device.

Maintenance

The PowerMasterTwin requires

minimal maintenance. It is advised

that the unit is visually inspected and

its functioning checked monthly. Also

the unit should be rinsed through

with warm water and a minimum of

bleach or other appropriate cleaning

product every 2–3 weeks to assist in

breaking down any solids that may

accumulate within the chamber.

NOTE – It is recommended that a

service agreement be taken out with

technically qualified company.

Health & safety

As with all site work, the danger of

working with water and electricity

can pose a severe threat to

health if obvious and fundamental

precautions are not taken. Therefore

if you are in any doubt regarding the

installation, please contact us.

All site work must be undertaken by

qualified personnel only.

These notes are for guidance only

and it is for the installer to ensure

the installation is in accordance

with all structural and regulatory

requirements.

Model PowerMasterTwin

Power Supply 230V AC / 400V AC

Rated Current 7.8A / 4.0A

Motor Rating 1300W / 1700W

Frequency 50Hz / 50Hz

Revolutions per Minute

2900rpm / 2900rpm

Max. Vertical Output 23m / 31m

Max. Horizontal Output

250m / 350m

Max. Flow Rate 138l/m / 153l/m

Max. Liquid Temp. <40°C / <40°C

Discharge Size 1¼" / 1¼"

Cable Length 4m / 4m

Weight 103kg / 98kg

Colour White

DIMENSIONS

The Company reserves the right to make any alterations in the

interest of technical development.

Model Length Width Height

PowerMasterTwin 956mm 855mm 528mm

Page 58: Product Catalogue - ESIcms.esi.info/Media/documents/Edinc_Catalog_ML.pdf · • Optimum performance of prthe pump system; • Improved environmental conditions. Our service agreements

RAINWATER HARVESTING SYSTEMS58

WATERGUARD ™

The Waterguard is a fully automatic

rainwater harvesting system used

for the collection and supply of

rainwater within both domestic and

commercial applications.

The system is suitable for installing either at the

initial building stage or retro fitting to existing

buildings. It is designed to accept rainwater from

downpipes, which is then filtered into a collection

tank ready to be used within buildings to serve

all non-potable water appliances (WC, washing

machine, outdoor tap).

The system consists of a GRP tank with

locking access cover, connections for

all connecting pipework, submersible

pump, internal & external filters,

sensors and control panel.

This system not only offers you

unrestricted use of your outdoor tap

but also saves you money through

reduced mains water consumption.

Waterguard 3000 (Direct & gravity)

Waterguard 2800 Budgie (Direct Only)

3000 litres storage capacity.

2800 litres storage capacity.

Waterguard 6000 (Direct & gravity)

6000 litres storage capacity.

gRAvITy SySTEM

The gravity system is installed using an additional header tank that supplies

filtered rainwater to the relevant appliance via gravity. The main advantage of

this system is in the event of a power failure the appliances are still served.

DIRECT SySTEM

The direct system is used where it is not possible to install an additional header

tank and therefore filtered rainwater is pumped direct from the holding tank to

the various appliances. The main advantage of this system is that rainwater is

delivered to the appliances at mains pressure (3.5 bar).

Waterguard 2800 Budgie

1YEAR

One-year GuaranteeTerms and conditions apply.

ServiCe aGreementSIt is essential this product undergoes routine servicing. Please contact our service dept. for further information.

Waterguard 12000 (Direct & gravity)

12000 litres storage capacity.

Page 59: Product Catalogue - ESIcms.esi.info/Media/documents/Edinc_Catalog_ML.pdf · • Optimum performance of prthe pump system; • Improved environmental conditions. Our service agreements

SPECIFICATIONSINSTALLATION gUIDELINES

59RAINWATER HARVESTING SYSTEMS

Tel 01442 211554

Fax 01442 211553

[email protected]

www.edincare.com

For prices and additional information please

contact Sales on 01442 211554

A high quality range of rainwater harvesting systems WATERGUARD™

It is important to note that these

instructions are for guidance only.

Please refer to the full Installation

and Operating Guidelines when

specifying / installing the product.

Siting the Product

It is recommended that the collection

tank be positioned at a minimum

distance of 5m from the face of any

building, so as not to affect either the

structural integrity of the building or

the tank.

It is imperative to assess the ground

conditions and water table level

prior to installation so as to provide

the necessary measures to prevent

floatation or movement of the tank.

Access to the collection tank is

very important, as there will be a

requirement for periodic maintenance

and desludging of the chamber.

Inlet Connections

The WaterGuard rainwater harvesting

system comes complete with a

110mm diameter inlet connecter

that will accept 110mm uPVC

underground drainage pipe. The

incoming pipework needs to be

pushed into the connector until a

waterproof seal is formed around the

pipework.

Overflow Connections

For connection of the rainwater

overflow pipe the WaterGuard is

supplied with a second 110mm

diameter connector that will accept

110mm uPVC underground drainage

pipe.

Discharge Connection

The WaterGuard rainwater harvesting

system comes complete with a 25mm

diameter tank connector suitable for

the connection of 25mm diameter

MDPE water main.

Model 2800 3000 6000 12000

Power Supply 230V AC 230V AC 230V AC 230V AC

Rated Current 2.3A 4.3A 4.3A 4.3A

Motor Rating 480W 600W 600W 600W

Frequency 50Hz 50Hz 50Hz 50Hz

Rev. per Minute 2600rpm 2900rpm 2900rpm 2900rpm

Discharge Size 25mm 25mm 25mm 25mm

Cable Length 10m 20m 20m 20m

Weight 125Kg 130kg 160kg 535kg

Colour White Green Green Green

Model Diameter Length Height

WaterGuard2800 1905mm N/A 2165mm

WaterGuard3000 1225mm 3060mm 1775mm

WaterGuard6000 1440mm 4530mm 1960mm

WaterGuard12000 2010mm 4640mm 2655mm

DIMENSIONS

The Company reserves the right to make any alterations in the

interest of technical development.

Electrical Connection

A qualified person in accordance with

the Institute of Electrical Engineers

Regulations should connect the

unit to the appropriate mains supply

taking into account all the electrical

information provided.

IMPORTANT – The WaterGuard

rainwater harvesting system must be

used with an appropriate motor rated

protection device.

Maintenance

It is essential that the WaterGuard

rainwater harvesting system be

periodically maintained every

12 months to ensure optimum

performance of the unit.

It is also advised that the filters on

the incoming 110mm pipework are

checked every 2-4 weeks for any

materials that may impede the flow of

water into the collection tank.

Health and Safety

As with all site work, the danger of

working with water and electricity

can pose a serious threat to

health if obvious and fundamental

precautions are not taken. Therefore

if you are in any doubt regarding the

installation, please contact us.

All site work must be undertaken by

qualified personnel only.

These notes are for guidance only

and it is for the installer to ensure

the installation is in accordance

with all the structural and regulatory

requirements.

Page 60: Product Catalogue - ESIcms.esi.info/Media/documents/Edinc_Catalog_ML.pdf · • Optimum performance of prthe pump system; • Improved environmental conditions. Our service agreements

1YEAR

One-year GuaranteeTerms and conditions apply.

ServiCe aGreementSIt is essential this product undergoes routine servicing. Please contact our service dept. for further information.

FAT, OIL AND GREASE SEPARATOR SYSTEMS60

GREASEGUARDIAN

The grease guardian is a fully automatic grease

removal system suitable for the collection,

separation and removal of fat, oil and grease

from grey water before final discharge.

The system is suitable for installing either at the

initial building stage or retro fitting to existing

buildings and can accept waste from sinks or similar.

The system consists of a stainless steel tank with

odour tight lock down lid, collection basket, built-in

operating timer and heated skimming wheel.

Solids CollectionWaste water from the kitchen is directed through

the inlet of the Grease Guardian where a removable

strainer basket collects any solid debris.

grease and Oil SeparationGrease in the waste water floats to the

surface and is trapped while the clear

water leaves the unit and enters the

drainage system.

Cleaning and grease RemovalThe timer-driven heating element is

activated to liquefy grease, which is

then removed by the skimming wheel

and deposited into a portable container

for recycling.

grease guardian 1

Maximum flow rate 0.75l/s, 2" Inlet & Outlet

grease guardian 2

Maximum flow rate 1.25l/s, 2" Inlet & Outlet

grease guardian 3

Maximum flow rate 1.75l/s, 3" Inlet & Outlet

grease guardian 4

Maximum flow rate 2.25l/s, 4" Inlet & Outlet

grease guardian 5

Maximum flow rate 3.5l/s, 4" Inlet & Outlet

Page 61: Product Catalogue - ESIcms.esi.info/Media/documents/Edinc_Catalog_ML.pdf · • Optimum performance of prthe pump system; • Improved environmental conditions. Our service agreements

SPECIFICATIONSINSTALLATION gUIDELINES

61FAT, OIL AND GREASE SEPARATOR SYSTEMS

Tel 01442 211554

Fax 01442 211553

[email protected]

www.edincare.com

For prices and additional information please

contact Sales on 01442 211554

Automatic environmentally friendly grease separating system GREASEGUARDIAN

It is important to note that these

instructions are for guidance only.

Please refer to the full Installation

and Operating Guidelines when

specifying / installing the product.

Siting the product

The Grease Guardian should be

positioned on a firm level surface,

resistant to condensation. The unit

must be located lower than the

outflow of the appliances served so as

to provide a gravity fall into the unit.

It is extremely important to site the

Grease Guardian with access in mind

in the event of maintenance being

required.

Inlet connections

The system comes with an inlet

connector to accept incoming

pipework (inlet size is dependent of

size of unit).

Outlet connection

The system comes with a discharge

connector that is to be used for

connection to your discharge line.

The discharge line should be run to

the drainage point ensuring that the

pipework is run with a fall.

Electrical connection

A qualified person in accordance with

the Institute Of Electrical Engineers

Regulations should connect the

unit to the appropriate mains supply

taking into account all the electrical

information provided.

IMPORTANT – All systems must be

used with an appropriate motor rated

protection device.

Maintenance

The Grease Guardian requires

minimal maintenance. It is advised

that both the grease collection sump

and particle sump (located within the

tank) are checked daily and disposed

of as and when required, with a full

inspection undertaken twice yearly by

a service engineer.

NOTE – It is recommended that a

service agreement be taken out with

technically qualified company.

Health & safety

As with all site work, the danger of

working with water and electricity

can pose a severe threat to

health if obvious and fundamental

precautions are not taken. Therefore

if you are in any doubt regarding the

installation, please contact us.

All site work must be undertaken by

qualified personnel only.

These notes are for guidance only

and it is for the installer to ensure

the installation is in accordance

with all structural and regulatory

requirements.

Model gg1 gg2 gg3 gg4 gg5

Power Supply 230V AC 230V AC 230V AC 230V AC 230V AC

Rated Current 4.5A 4.5A 4.5A 4.5A 9.0A

Motor Rating 1000W 1000W 1000W 1000W 2000W

Frequency 50Hz 50Hz 50Hz 50Hz 50Hz

Rev. per Minute 1200rpm 1200rpm 1200rpm 1200rpm 1200rpm

Max. Flow Rate 0.75l/s 1.25l/s 1.75l/s 2.25l/s 3.5l/s

Max. Liqu. Temp. <90˚C <90˚C <90˚C <90˚C <90˚C

Inlet Size 2" 2" 3" 4" 4"

Discharge Size 2" 2" 3" 4" 4"

Cable Length 3m 3m 3m 3m 3m

Weight 30kg 32kg 35kg 36kg 45kg

Colour Silver Silver Silver Silver Silver

Model Diameter Length Height

Grease Guardian 1 640mm 340mm 320mm

Grease Guardian 2 720mm 340mm 410mm

Grease Guardian 3 840mm 340mm 450mm

Grease Guardian 4 890mm 340mm 450mm

Grease Guardian 5 1420mm 340mm 560mm

DIMENSIONS

The Company reserves the right to make any alterations in the

interest of technical development.

Page 62: Product Catalogue - ESIcms.esi.info/Media/documents/Edinc_Catalog_ML.pdf · • Optimum performance of prthe pump system; • Improved environmental conditions. Our service agreements

1YEAR

One-year GuaranteeTerms and conditions apply.

ServiCe aGreementSIt is essential this product undergoes routine servicing. Please contact our service dept. for further information.

FAT, OIL AND GREASE SEPARATOR SYSTEMS62

The BioDose is a fully automatic dosing system

suitable for dosing grease separator systems.

The system is suitable for installing either at the initial

building stage or retro fitting to existing buildings.

The system consists of an enclosure, dosing pump

with a fused spur.

The BioDose is to be used in conjunction with BioFax

a grease digesting enzyme.

ACCESSORIES

Biofax

BIODOSE ™

Page 63: Product Catalogue - ESIcms.esi.info/Media/documents/Edinc_Catalog_ML.pdf · • Optimum performance of prthe pump system; • Improved environmental conditions. Our service agreements

SPECIFICATIONSINSTALLATION gUIDELINES

63FAT, OIL AND GREASE SEPARATOR SYSTEMS

Tel 01442 211554

Fax 01442 211553

[email protected]

www.edincare.com

For prices and additional information please

contact Sales on 01442 211554

Automatic dosing system for grease separators BIODOSE ™

It is important to note that these

instructions are for guidance only.

Please refer to the full Installation

and Operating Guidelines when

specifying / installing the product.

Siting the product

The BioDose should be located

on a wall next to the main sink or

separating system. It is important that

the BioDose is positioned above the

appliance to be served and no more

than 5m away.

Connection to drainage system

The BioDose should be connected to

the drainage system using the fittings

provided with the unit. The BioDose

should inject the grease digesting

enzyme into the pipeline within

1000mm of the waste pipe entering

the fat trap to ensure the best

possible distribution of the enzyme

into the unit.

An 8mm hole must be drilled into

the top of the waste pipe after the

u-bend of the appliance served to

which the provided saddle clamp

should be fitted ensuring the drilled

8mm hole is in the centre. Once the

saddle clamp is in place screw the

hosetail fitting onto the saddle clamp.

Finally cut the 9.5mm tubing to length

ensuring the line from the BioDose

is as straight as possible but not

too tight and fix into place over the

hosetail on the saddle clamp and

onto the discharge line of the pump.

Changing the enzyme

To change the 5 litre container of

BioFax enzyme you must remove

the 9.5mm tubing from the container

located within the steel enclosure

and lift the empty container out.

Now unscrew the lid and the plastic

down pipe from the container and

screw into position on the new

5 litre container. Now place the

container back into position within the

enclosure and push the 9.5mm tubing

through the lid until it reaches the

bottom of the bottle. Prime the pump

using the button on the front of the

pump and then close the enclosure.

Electrical connection

A qualified person in accordance with

the Institute Of Electrical Engineers

Regulations should connect the

unit to the appropriate mains supply

taking into account all the electrical

information provided.

IMPORTANT – All pump systems

must be used with an appropriate

motor rated protection device.

Maintenance

The BioDose requires minimal

maintenance. It is advised that when

the 5 litre bottle of Biofax is changed

the inlet and outlet tubing are

checked for any blockages or build

up of material that may impede the

flow of BioFax enzyme.

Health & safety

As with all site work, the danger of

working with water and electricity

can pose a severe threat to

health if obvious and fundamental

precautions are not taken. Therefore

if you are in any doubt regarding

the installation, please contact us.

All site work must be undertaken by

qualified personnel only.

These notes are for guidance only

and it is for the installer to ensure

the installation is in accordance

with all structural and regulatory

requirements.

Model BioDose

Power Supply 230V AC

Rated Current 0.3A

Motor Rating 5W

Frequency 50Hz

Revolutions per Minute

30rpm

Max. Discharge Length

10m

Max. Flow Rate 32ml/m

Max. Liquid Temp. <40°C

Discharge Size 9.5mm tubing

Cable Length 5m

Weight 12kg

Colour Cream

Model Length Width Height

BioDose 400mm 300mm 210mm

DIMENSIONS

The Company reserves the right to make any alterations in the

interest of technical development.

Page 64: Product Catalogue - ESIcms.esi.info/Media/documents/Edinc_Catalog_ML.pdf · • Optimum performance of prthe pump system; • Improved environmental conditions. Our service agreements

1YEAR

One-year GuaranteeTerms and conditions apply.

ServiCe aGreementSIt is essential this product undergoes routine servicing. Please contact our service dept. for further information.

ECOTRAP ™ Environmentally friendly grease separating systems

The EcoTrap is an environmentally friendly

grease separator system suitable for

separating grease and fat from grey water

before final discharge.

The system is suitable for installing either at the

initial building stage or retro fitting to existing

buildings and can accept waste connections from

a sink or similar.

The system consists of a GRP/polypropylene tank

with odour tight lid, the inlet is pre-cut on the

opposite side from the outlet.

The EcoTrap is to be used in conjunction with

BioFax a grease digesting enzyme.

EcoTrap180

EcoTrap120

Length 600mm, Width 450mm, Height 550mm.

4" inlet and outlet.

EcoTrap240

EcoTrap300

Length 600mm, Width 600mm, Height 550mm.

4" inlet and outlet.

Length 750mm, Width 600mm, Height 550mm.

4" inlet and outlet.

Length 1200mm, Width 450mm, Height 550mm.

4" inlet and outlet.

ACCESSORIES

Biofax

FAT, OIL AND GREASE SEPARATOR SYSTEMS64

Page 65: Product Catalogue - ESIcms.esi.info/Media/documents/Edinc_Catalog_ML.pdf · • Optimum performance of prthe pump system; • Improved environmental conditions. Our service agreements

PROTRAP ™

1YEAR

One-year GuaranteeTerms and conditions apply.

ServiCe aGreementSIt is essential this product undergoes routine servicing. Please contact our service dept. for further information.

65FAT, OIL AND GREASE SEPARATOR SYSTEMS

Environmentally friendly grease separating systems

ACCESSORIES

Biofax

The ProTrap™ is an environmentally

friendly grease separator system suitable

for separating grease and fat from grey

water before final discharge.

The system is suitable for installing either at the

initial building stage or retro fitting to existing

buildings and can accept waste connections from

sinks or similar

The system consists of a stainless steel tank with

odour tight lock down lid. It also benefits from a

collection basket for easy removal of larger food

particles.

The ProTrap is to be used in conjunction with

BioFax a grease digesting enzyme.

ProTrap100

ProTrap70

Length 640mm, Width 340mm,

Height 330mm, 2" Inlet & Outlet.

ProTrap130

Length 720mm, Width 340mm,

Height 410mm, 2" Inlet & Outlet.

Length 840mm, Width 340mm,

Height 450mm, 2" Inlet & Outlet.

Page 66: Product Catalogue - ESIcms.esi.info/Media/documents/Edinc_Catalog_ML.pdf · • Optimum performance of prthe pump system; • Improved environmental conditions. Our service agreements

EDINCARE PUMPED DRAINAGE SYSTEMS

Code Model volt Audio visual

7001 HighLevelAlarm‘Mini’(MainsOperated) 230V Yes Yes

7002 HighLevelAlarm‘Mini’(Battery&MainsOperated) 230V Yes Yes

2130 HighLevelAlarm‘Sump’(MainsOperated) 230V Yes Yes

4053 HighLevelAlarm‘Sump’(Battery&MainsOperated) 230V Yes Yes

Code Model Length

3106 Sewage Float Multi Contact MC 6m

3107 Sewage Float Multi Contact MC 13m

3108 Sewage Float Multi Contact MC 20m

3109 Sewage Float Multi Contact MC 30m

3110 Sewage Float Multi Contact MC 50m

HIgH LEvEL ALARMS

‘Mini’HighLevelAlarmssuppliedwithMicroSwitchand‘Sump’HighLevelAlarmssuppliedwith13metre

Sewage Float Multi Contact MC 13m.

FLOATS

Floats come complete with plastic counter weight.

Code Model

7010 Mac3Float&Gland(SupplyOnly)

7011 Mac3Float&Gland(Supply&FitinWorkshop)

7012 Agma 22 c/w 10m Cable (Supply Only)

7013 Agma22c/w10mCable(Supply&FitinWorkshop)

7014 Jung Float Arm (Supply Only)

7015 JungFloatArm(Supply&FitinWorkshop)

7016 Jung Low Level Float (Supply Only)

7017 JungLowLevelFloat(Supply&FitinWorkshop)

All cable joints undertaken within workshop must allow 24 hours to cure.

ACCESSORIES

66

Page 67: Product Catalogue - ESIcms.esi.info/Media/documents/Edinc_Catalog_ML.pdf · • Optimum performance of prthe pump system; • Improved environmental conditions. Our service agreements

67EDINCARE PUMPED DRAINAGE SYSTEMS

ACCESSORIES

Code Model Size

70000 Biofax (1 Month Supply 1 x bottle) 5 litres

70001 Biofax (1 Month Supply 30 x bottles) 200ml

70002 Biofax (12 Month Supply 12 x bottles) 5 litres

70006 Biofax (12 Month Supply 12 x 30 bottles) 200ml

Code Model Material

3073 Float Bracket (2 Float) Stainless Steel

3074 Float Bracket (3 Float) Stainless Steel

FLOAT BRACkETS

Code Model Material

3854 Counter Weight Plastic

3855 Counter Weight Metal

COUNTER WEIgHTS

Code Model Length

3075 MDPE Black Discharge Pipe Work 32mm OD 25m

3076 MDPE Black Discharge Pipe Work 32mm OD 50m

3078 MDPE Black Discharge Pipe Work 50mm OD 25m

3079 MDPE Black Discharge Pipe Work 50mm OD 50m

3081 MDPE Black Discharge Pipe Work 63mm OD 25m

3082 MDPE Black Discharge Pipe Work 63mm OD 50m

3084 HDPE Black Discharge Pipe Work 90mm OD 50m

3086 HDPE Black Discharge Pipe Work 110mm OD 50m

MDPE/HDPE PIPE WORk

Code Model

3090 Compression Adaptor 32mm ID

3093 Compression Adaptor 50mm ID

3094 Compression Adaptor 63mm ID

7030 Compression Adaptor 90mm ID

7031 Compression Adaptor 110mm ID

COMPRESSION ADAPTORS

BIOFAX (gREASE DIgESTINg ENzyME)

EDINCARE PUMPED DRAINAGE SYSTEMS 67

Page 68: Product Catalogue - ESIcms.esi.info/Media/documents/Edinc_Catalog_ML.pdf · • Optimum performance of prthe pump system; • Improved environmental conditions. Our service agreements

Code Model Duty

3001 Control Panel (Single Pump) 1 Phase (1–4kW) 1x1ph

3002 Control Panel (Dual Pump) 1 Phase (1–4kW) 2x1ph

7050 Control Panel (Single Pump) 3 Phase (1–4kW) 1x3ph

7051 Control Panel (Dual Pump) 3 Phase (1–4kW) 2x3ph

CONTROL PANELS

All control panels come complete with the following as standard: Direct on line start, IP54 Enclosure, Overload

fitted to suit particular pump motor, Hand/Off/Auto selector switch(es), High Level Audible alarm with mute

button,Doorlockingisolator,Visualindicationfor:‘pump(s)running’,‘pump(s)tripped’,‘highlevel’,24VAC

output connection for remote beacon (to indicate high-level), Klixon connections. (all control panels offered in

2, 3 or 4 float setup).

CONTROL PANEL (ACCESSORIES)

Code Model

7060 Remote Beacon, 24V AC

7061 Guard for Beacon

7062 Remote Sounder, 24V AC

7063 Telemetry System with BT Phone plug

7067 Telemetry System (GSM)

7064 Ammeter (per pump)

7065 Hours run meter (per pump)

7066 Seal leak relay and lamp (per pump)

kIOSkS

Code Model

1205 Kiosk (Floor Mounted, Single Door)

ACCESS COvERS

Code Model Duty

2900 Access Cover, Locking, 600mm x 450mm Pedestrian

2901 Access Cover, Locking, 600mm x 600mm Pedestrian

2905 Access Cover, Locking, 750mm x 600mm Pedestrian

2907 Access Cover, Locking, 900mm x 600mm Pedestrian

2903 Access Cover, Double Sealed, Locking, Inlay 600mm x 450mm Pedestrian

2904 Access Cover, Double Sealed, Locking, Inlay 600mm x 600mm Pedestrian

2138 Access Cover, Double Sealed, Locking, Inlay 750mm x 600mm Pedestrian

2139 Access Cover, Double Sealed, Locking, Inlay 900mm x 600mm Pedestrian

LIFTINg CHAINS

Code Model

7080 Lifting Chain (Max 300kg) per metre

7081 Shackle

EDINCARE PUMPED DRAINAGE SYSTEMS

ACCESSORIES

68

Page 69: Product Catalogue - ESIcms.esi.info/Media/documents/Edinc_Catalog_ML.pdf · • Optimum performance of prthe pump system; • Improved environmental conditions. Our service agreements

69

ENQUIRY SPECIFICATION SHEET

IN ORDER FOR EDINCARE TO SPECIFy THE CORRECT PUMPINg STATION FOR yOUR PARTICULAR APPLICATION WE REqUIRE

SPECIFIC DETAILS OF THE PUMPINg DUTy. PLEASE PHOTOCOPy AND COMPLETE THE FORM, THEN FAX TO 01442 211553.

TYPICAL INSTALLATIONCONTACT DETAILS

SITE SPECIFICATIONS

SITE DETAILS

GENERAL DESCRIPTION

NOTE

All applications that involve pumping downhill must be highlighted

at the earliest opportunity.

Control panel

Inlet depth (A)

Outfall chamber

Pumping distance (C)

(B)

Discha

rge

Company name .............................................................................

Customer name .............................................................................

Address .........................................................................................

........................................................................................................

Postcode .......................................................................................

Phone ............................................................................................

Fax .................................................................................................

Email ..............................................................................................

Site / Scheme name .......................................................................

Address ..........................................................................................

........................................................................................................

Postcode ........................................................................................

Depth from ground level to inlet level (A). ........................................

Difference in level between inlet level and

discharge into outfall chamber (B). .................................................

Total distance from pump chamber to

outfall chamber (C). ........................................................................

If rising main is existing, please state:

Diameter (internal diameter) ........................................................

Rising main material (MDPE, HDPE, Ductile Iron) ........................

Fluid medium (please tick applicable).

Foul Drainage Storm

Number of properties. .....................................................................

Bedrooms per property. .................................................................

Capacity required, if known. ...........................................................

Any special requirements. ...............................................................

Anticipated daily fl ow, if known. ......................................................

Surface water area drained .............................................................

Surface type:

Roof Paved Carriage Lawn

Other ...........................................................................................

Electrical power supply available:

240v/1ph 415v/3ph

Will the pumping station be adopted?

Yes No

If ‘Yes’ to question above,

who is the adopting authority? ...................................................

When do you require the pumping station? ....................................

........................................................................................................

........................................................................................................

........................................................................................................

EDINCARE PUMPED DRAINAGE SYSTEMS 69

Page 70: Product Catalogue - ESIcms.esi.info/Media/documents/Edinc_Catalog_ML.pdf · • Optimum performance of prthe pump system; • Improved environmental conditions. Our service agreements

ACCOUNT OPENING FORM

Contact Name: ...............................................................................................................................................................................

Company Name: ...............................................................................................................................................................................

Company Address: ...............................................................................................................................................................................

...............................................................................................................................................................................

...............................................................................................................................................................................

...............................................................................................................................................................................

...............................................................................................................................................................................

Postcode: ...............................................................................................................................................................................

Company Telephone: ...............................................................................................................................................................................

Company Fax: ...............................................................................................................................................................................

Company Email: ...............................................................................................................................................................................

Company Website: ...............................................................................................................................................................................

Company Registration Number: ...............................................................................................................................................................................

Bank (Name only): ...............................................................................................................................................................................

Bank Sort Code: ...............................................................................................................................................................................

Edincare use only

Account No: Terms:

Credit Limit: Date: / /

INPUT

INPUT

PLEASE PHOTOCOPy AND COMPLETE THE FORM, THEN FAX TO 01442 211553.

EDINCARE PUMPED DRAINAGE SYSTEMS70

Page 71: Product Catalogue - ESIcms.esi.info/Media/documents/Edinc_Catalog_ML.pdf · • Optimum performance of prthe pump system; • Improved environmental conditions. Our service agreements

FLOW & MEASUREMENT CHART

Flow &

Pressure APProximAte equivAlents

PRESSURES FLOW RATES

Bar (kg/cm²)

Metres of water

PSIFeet of water

Atmospheres

0.5 5 7.25 16.73 0.49

1.0 10 14.50 33.45 0.97

1.5 15 21.75 50.18 1.48

2.0 20 29.00 66.91 1.97

2.5 25 36.25 83.64 2.47

3.0 30 43.51 100.36 2.96

3.5 35 50.76 117.10 3.45

4.0 40 58.01 133.82 3.95

4.5 45 65.26 150.55 4.44

5.0 50 72.51 167.27 4.93

gPM LPM

1.0 4.545

2.0 9.09

3.0 13.64

4.0 18.18

5.0 22.73

6.0 27.27

7.0 31.82

8.0 36.36

9.0 40.91

10.0 45.45

Metres of water × 0.1 = Bars (kg per sq. cm)

× 3.281 = Feet of water

× 1.422 = Pounds per square inch

× 0.097 = Atmospheres

Pounds per sq. inch (PSI) × 0.07 = Bars (kg per sq. cm)

× 0.703 = Metres of water

× 2.3 = Feet of water

× 0.068 = Atmospheres

Feet of water × 0.03 = Bars (kg per sq. cm)

× 0.305 = Metres of water

× 0.434 = Pounds per square inch

× 0.029 = Atmospheres

Atmospheres x 1.003 = Bars (kg per sq. cm)

x 10.33 = Metres of water

x 33.9 = Feet of water

x 14.7 = Pounds per square inch

Litres per minute × 13.2 = Gallons per hour

Metres³ per hour × 0.28 = Litres per second

Litres per second × 3.6 = Metres³ per hour

Metres³ per second × 1000 = Litres per second

Metres³ per minute × 16.7 = Litres per second

Litres per hour × 1000 = Metres³ per hour

1cm³ = 0.061in³

1inch³ = 16.387cm³

1ft³ = 0.028m³

1m³ = 35.315ft³

1m³ = 1000 litres

1m³ = 220 gallons

1litre = 0.035ft³

1litre = 0.220 gallons

1litre = 0.001m³

1litre = 1000 cm³

1gallon = 4.545 litres

1gallon = 0.004545m³

1cm² = 0.155in²

1in² = 6.452cm²

1ft² = 0.093m²

1m² = 10.764ft²

1m² = 10,000cm²

1 hectare = 10,000m²

1km² = 100 hectares

1km² = 0.386 square mile

1mile² = 2.590km²

1mm = 0.039in

1cm = 0.394in

1in = 2.540cm

1ft = 0.305m

1ft = 12in

1m =3.281ft

1km = 0.621 miles

1mile = 1.609km

°C °F

-17.8 0

-10 14

0 32

10 50

20 68

30 86

40 104

50 122

60 140

70 158

80 176

90 194

100 212

C = Celsius or Centigrade

F = Fahrenheit

Bars (kg per sq. cm) × 10 = Metres of water

× 33.45 = Feet of water

× 14.5 = Pounds per square inch

× 0.97 = Atmospheres

gallons per minute × 4.545 = Litres per minute

Litres per minute × 0.22 = Gallons per minute

vOLUME AREA LENgTH WEIgHT

1oz = 28.35g

1lb = 16oz

1lb = 0.454kg

1kg = 2.205lb

1kg = 1000g

TEMPERATURE

C = (F − 32) ÷ 1.8

F = (1.8 × C) + 32

LPM gPM

5.0 1.10

10.0 2.20

15.0 3.30

20 4.40

25 5.50

30 6.60

35 7.70

40 8.80

45 9.90

50 11.00

useFul APProximAte equivAlents

EDINCARE PUMPED DRAINAGE SYSTEMS 71

Page 72: Product Catalogue - ESIcms.esi.info/Media/documents/Edinc_Catalog_ML.pdf · • Optimum performance of prthe pump system; • Improved environmental conditions. Our service agreements

NOTES

EDINCARE PUMPED DRAINAGE SYSTEMS72

.........................................................................................................................................................................................................................................................................................................................

.........................................................................................................................................................................................................................................................................................................................

.........................................................................................................................................................................................................................................................................................................................

.........................................................................................................................................................................................................................................................................................................................

.........................................................................................................................................................................................................................................................................................................................

.........................................................................................................................................................................................................................................................................................................................

.........................................................................................................................................................................................................................................................................................................................

.........................................................................................................................................................................................................................................................................................................................

.........................................................................................................................................................................................................................................................................................................................

.........................................................................................................................................................................................................................................................................................................................

.........................................................................................................................................................................................................................................................................................................................

.........................................................................................................................................................................................................................................................................................................................

.........................................................................................................................................................................................................................................................................................................................

.........................................................................................................................................................................................................................................................................................................................

.........................................................................................................................................................................................................................................................................................................................

.........................................................................................................................................................................................................................................................................................................................

.........................................................................................................................................................................................................................................................................................................................

.........................................................................................................................................................................................................................................................................................................................

.........................................................................................................................................................................................................................................................................................................................

.........................................................................................................................................................................................................................................................................................................................

.........................................................................................................................................................................................................................................................................................................................

.........................................................................................................................................................................................................................................................................................................................

.........................................................................................................................................................................................................................................................................................................................

.........................................................................................................................................................................................................................................................................................................................

.........................................................................................................................................................................................................................................................................................................................

.........................................................................................................................................................................................................................................................................................................................

.........................................................................................................................................................................................................................................................................................................................

.........................................................................................................................................................................................................................................................................................................................

.........................................................................................................................................................................................................................................................................................................................

.........................................................................................................................................................................................................................................................................................................................

.........................................................................................................................................................................................................................................................................................................................

.........................................................................................................................................................................................................................................................................................................................

.........................................................................................................................................................................................................................................................................................................................

.........................................................................................................................................................................................................................................................................................................................

.........................................................................................................................................................................................................................................................................................................................

.........................................................................................................................................................................................................................................................................................................................

.........................................................................................................................................................................................................................................................................................................................

.........................................................................................................................................................................................................................................................................................................................

.........................................................................................................................................................................................................................................................................................................................

.........................................................................................................................................................................................................................................................................................................................

.........................................................................................................................................................................................................................................................................................................................

.........................................................................................................................................................................................................................................................................................................................

Page 73: Product Catalogue - ESIcms.esi.info/Media/documents/Edinc_Catalog_ML.pdf · • Optimum performance of prthe pump system; • Improved environmental conditions. Our service agreements

NOTES

EDINCARE PUMPED DRAINAGE SYSTEMS 73

.........................................................................................................................................................................................................................................................................................................................

.........................................................................................................................................................................................................................................................................................................................

.........................................................................................................................................................................................................................................................................................................................

.........................................................................................................................................................................................................................................................................................................................

.........................................................................................................................................................................................................................................................................................................................

.........................................................................................................................................................................................................................................................................................................................

.........................................................................................................................................................................................................................................................................................................................

.........................................................................................................................................................................................................................................................................................................................

.........................................................................................................................................................................................................................................................................................................................

.........................................................................................................................................................................................................................................................................................................................

.........................................................................................................................................................................................................................................................................................................................

.........................................................................................................................................................................................................................................................................................................................

.........................................................................................................................................................................................................................................................................................................................

.........................................................................................................................................................................................................................................................................................................................

.........................................................................................................................................................................................................................................................................................................................

.........................................................................................................................................................................................................................................................................................................................

.........................................................................................................................................................................................................................................................................................................................

.........................................................................................................................................................................................................................................................................................................................

.........................................................................................................................................................................................................................................................................................................................

.........................................................................................................................................................................................................................................................................................................................

.........................................................................................................................................................................................................................................................................................................................

.........................................................................................................................................................................................................................................................................................................................

.........................................................................................................................................................................................................................................................................................................................

.........................................................................................................................................................................................................................................................................................................................

.........................................................................................................................................................................................................................................................................................................................

.........................................................................................................................................................................................................................................................................................................................

.........................................................................................................................................................................................................................................................................................................................

.........................................................................................................................................................................................................................................................................................................................

.........................................................................................................................................................................................................................................................................................................................

.........................................................................................................................................................................................................................................................................................................................

.........................................................................................................................................................................................................................................................................................................................

.........................................................................................................................................................................................................................................................................................................................

.........................................................................................................................................................................................................................................................................................................................

.........................................................................................................................................................................................................................................................................................................................

.........................................................................................................................................................................................................................................................................................................................

.........................................................................................................................................................................................................................................................................................................................

.........................................................................................................................................................................................................................................................................................................................

.........................................................................................................................................................................................................................................................................................................................

.........................................................................................................................................................................................................................................................................................................................

.........................................................................................................................................................................................................................................................................................................................

.........................................................................................................................................................................................................................................................................................................................

.........................................................................................................................................................................................................................................................................................................................

Page 74: Product Catalogue - ESIcms.esi.info/Media/documents/Edinc_Catalog_ML.pdf · • Optimum performance of prthe pump system; • Improved environmental conditions. Our service agreements

74

NOTES

EDINCARE PUMPED DRAINAGE SYSTEMS74

.........................................................................................................................................................................................................................................................................................................................

.........................................................................................................................................................................................................................................................................................................................

.........................................................................................................................................................................................................................................................................................................................

.........................................................................................................................................................................................................................................................................................................................

.........................................................................................................................................................................................................................................................................................................................

.........................................................................................................................................................................................................................................................................................................................

.........................................................................................................................................................................................................................................................................................................................

.........................................................................................................................................................................................................................................................................................................................

.........................................................................................................................................................................................................................................................................................................................

.........................................................................................................................................................................................................................................................................................................................

.........................................................................................................................................................................................................................................................................................................................

.........................................................................................................................................................................................................................................................................................................................

.........................................................................................................................................................................................................................................................................................................................

.........................................................................................................................................................................................................................................................................................................................

.........................................................................................................................................................................................................................................................................................................................

.........................................................................................................................................................................................................................................................................................................................

.........................................................................................................................................................................................................................................................................................................................

.........................................................................................................................................................................................................................................................................................................................

.........................................................................................................................................................................................................................................................................................................................

.........................................................................................................................................................................................................................................................................................................................

.........................................................................................................................................................................................................................................................................................................................

.........................................................................................................................................................................................................................................................................................................................

.........................................................................................................................................................................................................................................................................................................................

.........................................................................................................................................................................................................................................................................................................................

.........................................................................................................................................................................................................................................................................................................................

.........................................................................................................................................................................................................................................................................................................................

.........................................................................................................................................................................................................................................................................................................................

.........................................................................................................................................................................................................................................................................................................................

.........................................................................................................................................................................................................................................................................................................................

.........................................................................................................................................................................................................................................................................................................................

.........................................................................................................................................................................................................................................................................................................................

.........................................................................................................................................................................................................................................................................................................................

.........................................................................................................................................................................................................................................................................................................................

.........................................................................................................................................................................................................................................................................................................................

.........................................................................................................................................................................................................................................................................................................................

.........................................................................................................................................................................................................................................................................................................................

.........................................................................................................................................................................................................................................................................................................................

.........................................................................................................................................................................................................................................................................................................................

.........................................................................................................................................................................................................................................................................................................................

.........................................................................................................................................................................................................................................................................................................................

.........................................................................................................................................................................................................................................................................................................................

.........................................................................................................................................................................................................................................................................................................................

Page 75: Product Catalogue - ESIcms.esi.info/Media/documents/Edinc_Catalog_ML.pdf · • Optimum performance of prthe pump system; • Improved environmental conditions. Our service agreements

75

CONDITIONS OF SALE

1. general

These conditions of Sale (“the Conditions”)

supplied by Omni Pump International Ltd T/A

Edincare Pumped Drainage Systems (“the

Company”) to a purchaser (“the Buyer”) shall

be incorporated into each contract (“the

Contract”) made by the Company for the

sale of the Company’s goods (“the Goods”).

These Conditions apply to all transactions,

including deliveries and services, conducted

by the Company, as well as to their execution.

These Conditions together with invoice

details supersede any terms or conditions

proposed by the Buyer and may not be varied

except with the written consent of a Director

of the Company. In the case of a written

consent by a Director of the Company to a

variation or deviation from one or more of

these Conditions of Sale, the other terms and

conditions shall remain fully operative.

2. Exclusion of Liability

The Company excludes all liability for any

consequential or indirect loss suffered by the

Buyer whether this loss arises from breach of

a duty in contract or tort or in any other way

(including loss arising from the Company’s

negligence). Non-exhaustive illustrations of

consequential or indirect loss include:

(a)lossofprofit;

(b)lossofcontracts;

(c) damage to property of the Buyer or anyone

else;

(d) personal injury to the Buyer or anyone

else (when the injury is not caused by the

Company’s negligence).

3. Indemnities

The Buyer shall indemnify the Company

against all actions, claims, demands,

penalties and costs by third parties in tort

or for infringements of patents or registered

designs or otherwise arising in connection

with the Goods or with their delivery or

unloading or with work done by the Company

on the Goods in accordance with the Buyer’s

specifications.

4. Consumer Protection Act 1987

Where the Company incurs any liability,

whether by court proceedings or by a bona

fide out of court settlement as a result of a

claim against the Company under part 1 of

the Consumer Protection Act 1987 in respect

of an alleged defect in the Goods, then the

Buyer shall indemnify the Company against

the liability.

5. Deliveries

(a) Delivery shall take place when the Goods

are delivered at the address specified in

the Buyer’s order or in the absence of such

address at the Buyer’s premises except when

the Buyer collects or arranges collection of

the Goods from the Company’s premises, or

nominates a carrier for the Goods, delivery

shall take place when the Goods are loaded

on to the collection or carrier’s vehicle.

(b) Delivery dates mentioned in any quotation,

order or other document are approximate only

and not of any contractual effect. Late delivery

or performance does not entitle the Buyer

to do any of the following: reject late goods,

terminate the contract or withhold payment of

any part of the contract price.

(c) The Company reserves the right to make

delivery by instalments and to tender a

separate invoice in respect of each instalment.

Each delivery shall be considered a separate

transaction and the failure of any one delivery

shall not affect the performance of the

remainder of the Contract or liability for the

costs of the Goods delivered.

6. Inspection and Claims

(a) The Buyer shall upon delivery or, on

collection by the Buyer if appropriate, inspect

the Goods wherever it is possible to do so. If

inspection is impossible, the Buyer must write

on the delivery (or collection) note “Goods not

examined”.

(b) The Buyer shall notify the Company in

writing of any short delivery, defects or

damage reasonably discoverable on careful

inspection within 7 days of the Buyer’s

receipt of the Goods. In the absence of such

notification, the Company excludes all liability

in respect of short deliveries, defects or

damage.

7. Prices

(a) Prices quoted are in GBP Sterling and

exclusive of VAT (where applicable) and do not

include any charge for handling or delivery of

the Goods.

(b) All prices quoted or printed are subject, to

alteration without notice by the Company, and

all Goods will be invoiced at the prices ruling

at the date of despatch.

(c) Where orders are received for quantities

or shipments that are priced at less than the

minimum charge of the Company, then the

order will be priced at the standard charge.

(d) All tenders, quotations, offers and

estimates made by the Company are given

without obligation.

8. Payment

(a) Where accounts have been approved for

credit, payment terms are nett monthly.

(b) The Company reserves the right (in

the Company’s absolute discretion) to

vary or withdraw without notice any credit

arrangements made.

(c) The Company reserves the right to charge

interest at the rate of 2% per month on all

overdue accounts without prejudice to its right

of recovery of the Goods. Interest is deemed

to accrue on a day to day basis from and

including the date when payment was due.

(d) Without prejudice to any other rights or

remedies of the Company, any default by the

Buyer in making payment according to the

payment terms, shall entitle the Company to

suspend deliveries under the Contract or any

other contract so long as the default continues

and to treat the Contract as repudiated by

the Buyer and determined if the Buyer has

not, within 7 days of receiving written notice

from the Company, paid all sums due to the

Company.

(e) If the Buyer shall have a receiving order

made against them, or enter into any

composition or arrangement with their

creditors, or if being an incorporated company

shall have a receiver appointed, or shall pass

a resolution for winding up or a court shall

make an order to that effect, or if there shall

be any breach by the Buyer of any terms or

conditions hereof, the Company may, without

prejudice to its other rights or remedies, defer

or cancel any further deliveries.

(f) The Company reserves the right to demand

security for payment at any time before

continuing with or delivering any order.

(g) All payments are to be made in GBP

Sterling.

9. Title in the goods

Risk in the Goods shall pass to the

Buyer when the Goods are delivered.

Notwithstanding risk in the Goods passing to

the Buyer on delivery, title in the Goods shall

notpasstotheBuyeruntil;

Full payment being received by the Company

for the Goods and no other amounts then

being outstanding from the Buyer to the

Company in respect of other Goods supplied

by the Company.

Before title has passed to the Buyer and,

without prejudice to any of its other rights,

the Company shall have the unqualified right

to recover or resell the Goods or any of them

and may enter upon the Buyer’s premises or

any premises where the Company reasonably

believes the Goods to be situated, by its

servants or agents for that purpose. Should

the Buyer alter the Goods by subjecting them

to any manufacturing process or incorporating

them into another product or mixing them in

any way, then the resulting product (“Altered

Goods”) will pass into the ownership of

the Company until payment due under all

Contracts between the Company and the

Buyer has been made in full.

10. Until Title to the goods Passes

(a) The Goods will be held by the Buyer as

bailee and the Goods shall be kept separate

from the Buyer’s other Goods and shall

be clearly identifiable as belonging to the

Company.

(b) In the event of the sale or hire of the Goods

or Altered Goods by the Buyer, the Buyer

shall hold the proceeds of such sale or hire as

trustee for the Company.

(c) In the event of the sale or hire of the Goods

or Altered Goods by the Buyer in the ordinary

course of its business, the Buyer shall assign

its rights to recover the selling price or hire

charges from the third parties concerned to

the Company, if required to do so in writing by

the Company.

11. The Buyer’s power of sale shall cease

forthwith:

(a)UponwrittennoticefromtheCompany;or

(b) If a receiver or manager is appointed over

anyoftheassetsorundertakingsoftheBuyer;

or

(c) If a petition is presented for the appointment

of an administrator or a winding up petition is

presentedagainsttheBuyer;or

(d) If the Buyer goes into voluntary liquidation or

calls a meeting of or makes any arrangement or

compositionwithitscreditors;or

(e) If the Buyer commits any act of bankruptcy

or becomes unable to meet its debts within

the meaning of Section 123 of the Insolvency

Act 1986.

Whereupon the Buyer shall continue to hold the

Goods as bailee for return to the Company and

the Company shall have the unqualified right to

enter upon any premises where the Company

reasonably believes the Goods or Altered

Goods to be situated to take possession of

the Goods or Altered Goods or such of them

as remain.

12. quality

Subject to clauses 5 and 6 concerning

delivery, inspection and claims, the Buyer

acknowledges that he/she has inspected the

Goods and satisfied himself/herself from the

inspection that:

(a)The Goods are of merchantable quality and

(b) The Goods are fit for his/her purpose in

reliance on his/her own skill or judgement,

and that he/she has not relied for this

purpose upon the skill or judgement of

the Company unless specifically agreed

otherwise in writing between the Buyer and

the Company.

13. Description

All weights, measurements, dimensions,

drawings, capacities, specifications and

other particulars contained in photographs,

catalogues, price lists or advertising material

are approximate and any other information or

technical assistance given by the Company

is given in good faith and is for general

guidance only. No information supplied by the

Company constitutes a warranty, guarantee

or recommendation of the suitability of the

Goods for any purpose whatsoever.

If Goods are supplied in accordance with

the Buyer’s specifications, the Buyer shall be

solely responsible for the specifications. The

Buyer acknowledges the Goods are fit for the

purpose in reliance on his/her own skill and

judgement and that he/she has not relied for

this purpose upon the skill or judgement of

the Company and the Buyer will indemnify the

Company against all claims by the customers

of the Buyer and Sub-Buyer in this regard.

14. Returns

Goods cannot be accepted for return

without the prior consent of the Company

and compliance with the Company’s returns

procedures. A 30% handling charge will be

made on all returns (Company errors and

omissions excepted). Carriage charges will

be extra.

15. guarantee

If within the guarantee period of a product

any defect is discovered in respect of

workmanship, construction or material,

the Company will make good the defect or

replace the defective part at its expense

inside normal working hours at the

Company’s premises providing, written notice

is given immediately the defect is discovered

and that, if required by the Company, the part

or complete unit is returned to the Company’s

premises carriage paid. Spares or repaired

parts are delivered ex works exclusive of

fitting. The guarantee does not apply to

defects caused by incorrect installation,

abnormal conditions of working, accidents,

misuse or neglects. The Company’s

responsibility is in all cases limited to the cost

of making good the defect or replacing the

defective part at the Company’s premises

inside normal working hours. The Company

excludes all liability for any consequential or

other damage or losses which may occur.

16. Proper Law

All contracts to which these conditions

apply shall be governed by and construed in

accordance with English Law.

EDINCARE PUMPED DRAINAGE SYSTEMS 75

Page 76: Product Catalogue - ESIcms.esi.info/Media/documents/Edinc_Catalog_ML.pdf · • Optimum performance of prthe pump system; • Improved environmental conditions. Our service agreements

Our policy is one of continuous product improvement, we reserve the right to

change specifications and prices without prior notice. All information is given in

good faith. No responsibility can be accepted for errors, omissions or incorrect

assumptions. © Copyright 2008 Omni Pump International Ltd t/a Edincare Pumped

Drainage Systems. All rights reserved.

Distributed by:

TEL 01442 211554

FAX 01442 211553

EMAIL [email protected]

WEB www.edincare.com

HEAD OFFICE

Unit 8, Heron Business Park,

Eastman Way,

Hemel Hempstead,

Hertfordshire,

HP2 7FW

Design by Cro-Magnon www.cromagnon.co.uk

qUALITy

Edincare Pumped Drainage Systems is committed to high

standards from manufacturing through to after-sales.

PRODUCT AvAILABILITy

Our product range is readily available from your usual trade

source or directly from Edincare’s distribution hub.

DELIvERy

Orders are delivered on our next day service anywhere in the

United Kingdom. Same day / before 10.30am deliveries are

available upon request.

EASy PAyMENT OPTION

Pay by Mastercard, Visa, Delta and Maestro or by cheque.

Or open an account with us for 30 days credit.

gUARANTEED

All products are covered by our 12 month component guarantee.

Manufacturing ∙ Project Design ∙ Sales ∙ Commissioning ∙ Servicing ∙ Repairs