Sai Sree
EARTH FAULT RELAY TESTING SYSTEM
Product Code : SSID:ELE:104
EARTH FAULT REALY TESTING SYSTEM
is designed to provide ex-posure of protection device used to preventfaults in electrical circuits due to earth leakage cur-rent. The protection of electrical system is re-quired to maintainany device in operation without failure. There are various types of protective devices used in Power Systems. Theknowledge of protective devices helps to use them smartly and avoid system breakdown. Earth leakage currentgives rise to heat genera-tion and progressive failure of insulation which leads to earth faults & sparks. The EarthFault Relay detects the leakage current well before they cross threshold limit.This provides complete learning platform related with the connection of Earth Fault Relay in trans-missionline and testing of Earth Fault Relay. After experi-menting with the students will be able to use Earth Fault Relay in Power Sys-tems.
Features
• Inbuilt variable source• Big font LCD display for better visibility• Isolation transformer is provided for safe operation• Exclusive and rugged designed panel• Designed by considering all the safety precautions• Diagrammatic representation for the ease of connections• Learning material CD
Scope of Learning
• To study and verify the operating characteristics of Earth Fault Relay with different plug setting• To study connection of Earth Fault Relay in transmission line• To study testing of Earth Fault Relay
Sai Sree Infra DevelopersLOT NO: 9, GROUND FLOOR,
GRMR COMPLEX,PRASHANTHI NAGAR,KUKATPALLY, HYDERABAD-500072
Corporate O�ce Contact UsBranch O�ceSai Sree Infra DevelopersPLOT NO: 9, GROUND FLOOR, GRMR COMPLEX,PRASHANTHI NAGAR,KUKATPALLY, HYDERABAD-500072
H.No 48-18-4/3, FIRST FLOOR, NEAR MUNICIPAL PARK.NAGARJUNA NAGAR, VIJAYAWADA,AP-520008
E
TEL :+91 630 240 4229.
www.saisreeinfra.com
Technical Specifications
Mains Supply : 230V±10%V AC, 50HzVariacInput : 230VOutput : 0-270VCurrent : 0-2AIsolation TransformerRating : 1kVAPrimary Voltage : 0-230VSecondary Voltage : 0-230VEarth Fault RelayType : Electro-mechanical Inverse TimeNormal Voltage : 110V AC, 50HzPlug Setting : 0.5A, 0.75A, 1.0A, 1.25A, 1.50A,1.75A and 2ARheostat : 110O, 5ADisplay Measurement UnitDesign Technology : AVR RISC MicrocontrollerVoltmeter : 25 - 300VMeasurement Method : Direct ADC interfaceDisplay Resolution : 1VAmmeter : 0.2 - 5AMeasurement Method : CT based ADC interfaceDisplay Resolution : 0.01ATimerRange : 10mSec - 30minOperation : Automatic with relay start operatingLCD SpecificationNo. of lines : 2No. of Characters in each line : 16MCB : 6A (SPN)Dimensions (mm) : W 830 x D 355 x H 630Weight : 52kg (approximate)