9
These drawings show typical conditions for installing the CertainTeed Ceilings product shown. They should not be construed as a substitute for an architectural or engineering design and do not reflect the unique requirements of local codes, laws, statutes or regulations that may be applicable for a specific installtion. CertainTeed Ceilings assumes no liability for the accuracy or completeness of the drawings for a specific installation or the fitness of the drawings for a particulat purpose. The user is advised to consult with local licenced design professionals in order to assure compliance with all legal requirements. CertainTeed Ceilings is not licenced to provide professional engineering or architectural services. REPRESENTATIVE CUSTOMER SHEET TITLE SHEET NO. PROJECT TITLE PRODUCT DRWN DATE CHECK PROJECT LOCATION SHEET REFERENCE 02/24/21 7030FR Canopy A.D. Z.D. ARCHITECT Only the products that are identified as such on this document are FSC ® certified CertainTeed Ceiling Corporation 20 Moores Road Malvern, PA 19355 800-233-8990 Certificate Code: SCS-COC-006960 R F S C The mark of responsible forestry FSC C151918 R DATE REVISIONS # Nominal Size (ex. 48" x 96") (if applicable) Rating: Class A per ASTM E84 (MDF) Veneer Species : Veneer Species Finish: Clear Topcoat, 20% sheen Mounting: Channel Strut with Cable Hardware Kit REF (A&B/PD10) Core: 3/4" MDF Accessories: Acoustical Felt/Fleece (If applicable) Module: Type: Rectangle (Flat) Canopy Edge: Knife Edge Ceiling Flat Canopy Product Specifications Ceiling Flat Canopy With Knife Edge 7030FR Canopy Product Detail Set PD-01: Product Details and Basic Installation A. Section with Knife Edge B. Enlarged Beveled Edge C. Plan View with Knife Edge D. Reflected Ceiling Plan View with Knife Edge PD-02: Product Details and Basic Installation A. Section with 3/4" Trim Edge B. Enlarged 3/4" Trim Edge B2. 3/4" Edge with 4" Trim Edge C. Plan View with 3/4" Trim Edge D. Reflected Ceiling Plan View with 3/4" Trim Edge PD-03: Product Details and Basic Installation A. Section with 4" Trim Edge B. Enlarged 4" Trim Edge C. Plan View with 4" Trim Edge D. Reflected Ceiling Plan View with 4" Trim Edge PD-10: Suspension System Hardware Installation A. Hardware Assembly Isometric View B. Hardware Assembly View C. Hardware Assembly View PD-11: Suspension System Installation A. Isometric View (Knife Edge Panels Installation Guide) PD-12: Suspension System Installation A. Isometric View (3/4" Trim Edge Panels Installation Guide) PD-13: Suspension System with Perimeter Trim Installation A. Isometric View (4" Trim Edge Panels Installation Guide) PD-14: CISCA Tolerances, Product Notes, and Ordering Notes Product Detail Set Contents: PD-00 Nominal Size (ex. 48" x 96"), 12' Radius (if applicable) Rating: Class A per ASTM E84 (MDF) Veneer Species : Veneer Species Finish: Clear Topcoat, 20% sheen Mounting: Channel Strut with Cable Hardware Kit Core: 3/4" MDF Accessories: Acoustical Felt/Fleece (If applicable) 4" Trim (If applicable) Module: Type: Rectangle (Flat) Canopy Edge: Trim Edge (Edge Banded) Product Specifications Ceiling Flat Canopy With Trim Edge Nominal Size (ex. 48" x 96"), 12' Radius (if applicable) Rating: Class A per ASTM E84 (MDF) Veneer Species : Veneer Species Finish: Clear Topcoat, 20% sheen Mounting: Channel Strut with Cable Hardware Kit Core: 3/4" MDF Accessories: Acoustical Felt/Fleece (If applicable) Module: Type: Rectangle (Flat) Canopy Edge: 4" Trim Edge (Edge Banded) Product Specifications Ceiling Flat Canopy With 4" Trim Edge

Product Detail Set Contents: Ceiling Flat Canopy With

  • Upload
    others

  • View
    2

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Product Detail Set Contents: Ceiling Flat Canopy With

These drawings show typical conditions for installing the CertainTeed Ceilings product shown. They should not be construed as a substitute for an architectural or engineering design and do not reflect the unique requirements of local codes, laws, statutes or regulations that may be applicable for a specific installtion. CertainTeed Ceilings assumes no liability forthe accuracy or completeness of the drawings for a specific installation or the fitness of the drawings for a particulat purpose. The user is advised to consult with local licenced design professionals in order to assure compliance with all legal requirements. CertainTeed Ceilings is not licenced to provide professional engineering or architectural services.

REPRESENTATIVE

CUSTOMER

SHEET TITLE

SHEET NO.

PROJECT TITLE

PRODUCT

DRWNDATE CHECK

PROJECT LOCATION

SHEET REFERENCE

02/24/21

7030FR Canopy

A.D. Z.D.

ARCHITECT

Only the products that are identified assuch on this document are FSC® certified

Cer

tain

Teed

Cei

ling

Cor

pora

tion

20 M

oore

s Roa

dM

alve

rn, P

A 1

9355

800-

233-

8990

Certificate Code:

SCS-COC-006960

R

FSC

The mark ofresponsible forestry

FSC C151918R

DA

TERE

VIS

ION

S#

Nominal Size (ex. 48" x 96")(if applicable)

Rating: Class A per ASTM E84 (MDF)

Veneer Species: Veneer Species

Finish: Clear Topcoat, 20% sheen

Mounting: Channel Strut with Cable Hardware KitREF (A&B/PD10)

Core: 3/4" MDF

Accessories: Acoustical Felt/Fleece (If applicable)

Module:Type: Rectangle (Flat) Canopy

Edge: Knife Edge

Ceiling Flat Canopy

Product SpecificationsCeiling Flat Canopy With Knife Edge

7030FR CanopyProduct Detail Set

PD-01: Product Details and Basic InstallationA. Section with Knife EdgeB. Enlarged Beveled EdgeC. Plan View with Knife EdgeD. Reflected Ceiling Plan View with Knife Edge

PD-02: Product Details and Basic InstallationA. Section with 3/4" Trim EdgeB. Enlarged 3/4" Trim EdgeB2. 3/4" Edge with 4" Trim EdgeC. Plan View with 3/4" Trim EdgeD. Reflected Ceiling Plan View with 3/4" Trim Edge

PD-03: Product Details and Basic InstallationA. Section with 4" Trim EdgeB. Enlarged 4" Trim EdgeC. Plan View with 4" Trim EdgeD. Reflected Ceiling Plan View with 4" Trim Edge

PD-10: Suspension System Hardware InstallationA. Hardware Assembly Isometric ViewB. Hardware Assembly ViewC. Hardware Assembly View

PD-11: Suspension System InstallationA. Isometric View (Knife Edge Panels Installation Guide)

PD-12: Suspension System InstallationA. Isometric View (3/4" Trim Edge Panels Installation Guide)

PD-13: Suspension System with Perimeter Trim InstallationA. Isometric View (4" Trim Edge Panels Installation Guide)

PD-14: CISCA Tolerances, Product Notes, and Ordering Notes

Product Detail Set Contents:

PD-00

Nominal Size (ex. 48" x 96"), 12' Radius(if applicable)

Rating: Class A per ASTM E84 (MDF)

Veneer Species: Veneer Species

Finish: Clear Topcoat, 20% sheen

Mounting: Channel Strut with Cable Hardware Kit

Core: 3/4" MDF

Accessories: Acoustical Felt/Fleece (If applicable)4" Trim (If applicable)

Module:Type: Rectangle (Flat) Canopy

Edge: Trim Edge (Edge Banded)

Product SpecificationsCeiling Flat Canopy With Trim Edge

Nominal Size (ex. 48" x 96"), 12' Radius(if applicable)

Rating: Class A per ASTM E84 (MDF)

Veneer Species: Veneer Species

Finish: Clear Topcoat, 20% sheen

Mounting: Channel Strut with Cable Hardware Kit

Core: 3/4" MDF

Accessories: Acoustical Felt/Fleece (If applicable)

Module:Type: Rectangle (Flat) Canopy

Edge: 4" Trim Edge (Edge Banded)

Product SpecificationsCeiling Flat Canopy With 4" Trim Edge

Page 2: Product Detail Set Contents: Ceiling Flat Canopy With

Galvanized Strut

Cable HangingHardware

REF (A&B/PD10)

1/4-20 SteelInsert, 8" O.C.

3'-1

13 4"

5"1'

-67 8"

5"

APD01

7'-1112"

312" 2' (Suggested) TYP 31

2"

Reinforcement Angle provided to prevent bowingattached with 1/4-20 x 1/2" HH Bolt Factory Installed

into 1/4-20 Channel Nut with Spring. REF (C/PD10)

1'-6

7 8"

3'-1

13 4"

Grain Direction

MDF Core With Finished Face

APD01

7'-1112"

2' (Suggested)

Galvanized Strut

Cable HangingHardwareREF (A&B/PD10) 1/4-20 Steel

Insert, 8" O.C.

MDF Core With Finished Face

DPD01

CPD01 B

PD01

7'-1112"

312"

Reinforcement Angle provided toprevent bowing attached with

1/4-20 x 1/2" HH Bolt Factory Installedinto 1/4-20 Channel Nut with Spring

REF (C/PD10)

MDF Core WithVeneer Finished Face

MDF ClearFinished Face

34"

These drawings show typical conditions for installing the CertainTeed Ceilings product shown. They should not be construed as a substitute for an architectural or engineering design and do not reflect the unique requirements of local codes, laws, statutes or regulations that may be applicable for a specific installtion. CertainTeed Ceilings assumes no liability forthe accuracy or completeness of the drawings for a specific installation or the fitness of the drawings for a particulat purpose. The user is advised to consult with local licenced design professionals in order to assure compliance with all legal requirements. CertainTeed Ceilings is not licenced to provide professional engineering or architectural services.

REPRESENTATIVE

CUSTOMER

SHEET TITLE

SHEET NO.

PROJECT TITLE

PRODUCT

DRWNDATE CHECK

PROJECT LOCATION

SHEET REFERENCE

02/24/21

7030FR Canopy

A.D. Z.D.

ARCHITECT

Only the products that are identified assuch on this document are FSC® certified

Cer

tain

Teed

Cei

ling

Cor

pora

tion

20 M

oore

s Roa

dM

alve

rn, P

A 1

9355

800-

233-

8990

Certificate Code:

SCS-COC-006960

R

FSC

The mark ofresponsible forestry

FSC C151918R

DA

TERE

VIS

ION

S#

Nominal Size (ex. 48" x 96")(if applicable)

Rating: Class A per ASTM E84 (MDF)

Veneer Species: Veneer Species

Finish: Clear Topcoat, 20% sheen

Mounting: Channel Strut with Cable Hardware KitREF (A&B/PD10)

Core: 3/4" MDF

Accessories: Acoustical Felt/Fleece (If applicable)

Module:Type: Rectangle (Flat) Canopy

Edge: Knife Edge

PD-01

CPD-01

7030FR Plan View with Knife EdgeScale: 3/4" = 1'-0"

Ceiling Flat Canopy

Product Details and BasicInstallation

Product SpecificationsCeiling Flat Canopy

DPD-01

7030FR Reflected Ceiling Plan View with Knife EdgeScale: 3/4" = 1'-0"

APD-01

7030FR Section with Knife EdgeScale: 3/4" = 1'-0"

BPD-01

7030FR Enlarged Beveled EdgeScale: 1'-0" = 1'-0"Section View

Page 3: Product Detail Set Contents: Ceiling Flat Canopy With

3'-1

13 4"

5"5"

APD02

7'-1112"

312"

Cable HangingHardware

REF (A&B/PD10)

1/4-20 SteelInsert, 8" O.C.

2' (Suggested) TYP 312"

Reinforcement Angle provided to prevent bowingattached with 1/4-20 x 1/2" HH Bolt Factory Installed

into 1/4-20 Channel Nut with Spring. REF (C/PD10)

1'-6

7 8"1'

-67 8"

3'-1

13 4"Grain Direction

MDF Core With Finished Face

APD02

7'-1112"

2' (Suggested)

Galvanized Strut

Cable HangingHardwareREF (A&B/PD10)

MDF Core With Finished Face

DPD02

CPD02

BPD02

7'-1112"

312"

1/4-20 SteelInsert, 8" O.C.

Reinforcement Angle provided toprevent bowing attached with 1/4-20 x1/2" HH Bolt Factory Installed into 1/4-20

Channel Nut with Spring REF (C/PD10)

MDF Core WithVeneer Finished Face

VeneeredFinished Edge

34"

VeneeredFinished Edge

4" Trim

34"

MDF Core WithVeneer Finished Face

34"

90° PerimeterTrim Bracket

(C-116)

These drawings show typical conditions for installing the CertainTeed Ceilings product shown. They should not be construed as a substitute for an architectural or engineering design and do not reflect the unique requirements of local codes, laws, statutes or regulations that may be applicable for a specific installtion. CertainTeed Ceilings assumes no liability forthe accuracy or completeness of the drawings for a specific installation or the fitness of the drawings for a particulat purpose. The user is advised to consult with local licenced design professionals in order to assure compliance with all legal requirements. CertainTeed Ceilings is not licenced to provide professional engineering or architectural services.

REPRESENTATIVE

CUSTOMER

SHEET TITLE

SHEET NO.

PROJECT TITLE

PRODUCT

DRWNDATE CHECK

PROJECT LOCATION

SHEET REFERENCE

02/24/21

7030FR Canopy

A.D. Z.D.

ARCHITECT

Only the products that are identified assuch on this document are FSC® certified

Cer

tain

Teed

Cei

ling

Cor

pora

tion

20 M

oore

s Roa

dM

alve

rn, P

A 1

9355

800-

233-

8990

Certificate Code:

SCS-COC-006960

R

FSC

The mark ofresponsible forestry

FSC C151918R

DA

TERE

VIS

ION

S#

Nominal Size (ex. 48" x 96"), 12' Radius(if applicable)

Rating: Class A per ASTM E84 (MDF)

Veneer Species: Veneer Species

Finish: Clear Topcoat, 20% sheen

Mounting: Channel Strut with Cable Hardware Kit

Core: 3/4" MDF

Accessories: Acoustical Felt/Fleece (If applicable)4" Trim (If applicable)

Module:Type: Rectangle (Flat) Canopy

Edge: Trim Edge (Edge Banded)

PD-02

CPD-02

7030FR Plan View with 3/4" Trim EdgeScale: 3/4" = 1'-0"

Ceiling Flat Canopy

Product Details and BasicInstallation

Product SpecificationsCeiling Flat Canopy

DPD-02

7030FR Reflected Ceiling Plan View with 3/4" Trim EdgeScale: 3/4" = 1'-0"

APD-02

7030FR Section with 3/4" Trim EdgeScale: 3/4" = 1'-0"

BPD-02

7030FR Enlarged 3/4" Trim EdgeScale: 1'-0" = 1'-0"Section View

B2PD-03

7030FR 3/4" Edge with 4" Trim EdgeScale: 6" = 1'-0"Enlarged Section View

Page 4: Product Detail Set Contents: Ceiling Flat Canopy With

3'-1

13 4"

5"5"

APD03

7'-1112"

312" 31

2"4" Trim

Cable Hanging Hardware REF (A&B/PD10)

1/4-20 SteelInsert, 8" O.C.

2' (Suggested) TYP 312"

Reinforcement Angle provided to prevent bowingattached with 1/4-20 x 1/2" HH Bolt Factory Installed

into 1/4-20 Channel Nut with Spring. REF (C/PD10)

1'-6

7 8"1'

-67 8"

3'-1

13 4"Grain Direction

MDF Core With Finished Face

APD03

7'-1112"

2' (Suggested)

Galvanized Strut

Cable HangingHardwareREF (A&B/PD10) 1/4-20 Steel

Insert, 8" O.C.

MDF Core With Finished Face

DPD03

CPD03 B

PD03

7'-1112"

312"

Reinforcement Angle provided to preventbowing attached with 1/4-20 x 1/2" HH

Bolt Factory Installed into 1/4-20 ChannelNut with Spring REF (C/PD10)

4" Trim

34"

MDF Core WithVeneer Finished Face

VeneeredFinished Edge

34"

These drawings show typical conditions for installing the CertainTeed Ceilings product shown. They should not be construed as a substitute for an architectural or engineering design and do not reflect the unique requirements of local codes, laws, statutes or regulations that may be applicable for a specific installtion. CertainTeed Ceilings assumes no liability forthe accuracy or completeness of the drawings for a specific installation or the fitness of the drawings for a particulat purpose. The user is advised to consult with local licenced design professionals in order to assure compliance with all legal requirements. CertainTeed Ceilings is not licenced to provide professional engineering or architectural services.

REPRESENTATIVE

CUSTOMER

SHEET TITLE

SHEET NO.

PROJECT TITLE

PRODUCT

DRWNDATE CHECK

PROJECT LOCATION

SHEET REFERENCE

02/24/21

7030FR Canopy

A.D. Z.D.

ARCHITECT

Only the products that are identified assuch on this document are FSC® certified

Cer

tain

Teed

Cei

ling

Cor

pora

tion

20 M

oore

s Roa

dM

alve

rn, P

A 1

9355

800-

233-

8990

Certificate Code:

SCS-COC-006960

R

FSC

The mark ofresponsible forestry

FSC C151918R

DA

TERE

VIS

ION

S#

Nominal Size (ex. 48" x 96"), 12' Radius(if applicable)

Rating: Class A per ASTM E84 (MDF)

Veneer Species: Veneer Species

Finish: Clear Topcoat, 20% sheen

Mounting: Channel Strut with Cable Hardware Kit

Core: 3/4" MDF

Accessories: Acoustical Felt/Fleece (If applicable)

Module:Type: Rectangle (Flat) Canopy

Edge: 4" Trim Edge (Edge Banded)

PD-03

CPD-03

7030FR Plan View with 4" Trim EdgeScale: 3/4" = 1'-0"

Ceiling Flat Canopy

Product Details and BasicInstallation

Product SpecificationsCeiling Flat Canopy

DPD-03

7030FR Reflected Ceiling Plan View with 4" Trim EdgeScale: 3/4" = 1'-0"

APD-03

7030FR Section with 4" Trim EdgeScale: 3/4" = 1'-0"

BPD-03

7030FR Enlarged 4" Trim EdgeScale: 6" = 1'-0"Section View

Page 5: Product Detail Set Contents: Ceiling Flat Canopy With

Cable Coupler, Slot,Internally Threaded 1/4-20Externally 1/4-IP

3/32" stainlesssteel cable

2" OD Washer

7/8" x 1 5/8" strut

1/4-20 Channelnut with spring

1/4-20 x 1"Threaded stud

Reinforcement Angle- Factory Installed

7/8" x 1 5/8" strut

1/4-20 Channelnut with spring

1/4-20 x 1/2" HH Bolt

These drawings show typical conditions for installing the CertainTeed Ceilings product shown. They should not be construed as a substitute for an architectural or engineering design and do not reflect the unique requirements of local codes, laws, statutes or regulations that may be applicable for a specific installtion. CertainTeed Ceilings assumes no liability forthe accuracy or completeness of the drawings for a specific installation or the fitness of the drawings for a particulat purpose. The user is advised to consult with local licenced design professionals in order to assure compliance with all legal requirements. CertainTeed Ceilings is not licenced to provide professional engineering or architectural services.

REPRESENTATIVE

CUSTOMER

SHEET TITLE

SHEET NO.

PROJECT TITLE

PRODUCT

DRWNDATE CHECK

PROJECT LOCATION

SHEET REFERENCE

02/24/21

7030FR Canopy

A.D. Z.D.

ARCHITECT

Only the products that are identified assuch on this document are FSC® certified

Cer

tain

Teed

Cei

ling

Cor

pora

tion

20 M

oore

s Roa

dM

alve

rn, P

A 1

9355

800-

233-

8990

Certificate Code:

SCS-COC-006960

R

FSC

The mark ofresponsible forestry

FSC C151918R

DA

TERE

VIS

ION

S#

Ceiling Concave Canopy

Suspension SystemHardware Installation

PD-10

Trim off excess cable 3/32" stainlesssteel cable

Loosen lock cap to the lastthread before insertingcable into side exit gripperPress up the threaded tip

to adjust final length ofcable, then screw on the

lock cap

(GR-SE-1/4-IP) Side Exit CeilingCoupler Gripper that attaches

to structure above.1/4-20 Internally Threaded

1/4" IPS Externally

Cable Coupler, Slot,Internally Threaded 1/4-20

Externally 1/4-IP

2" ODWasher

1/4-20 x 1"Threaded stud

1/4-20 Channelnut with spring

7/8" x 1 5/8" strut

APD-10

Hardware Assembly Isometric ViewScale: 6"=1'-0"

BPD-10

Hardware Assembly ViewScale: 6"=1'-0"

CPD-10

Hardware Assembly ViewScale: 6"=1'-0"

Page 6: Product Detail Set Contents: Ceiling Flat Canopy With

Pre-curved 7/8"x1-5/8" strutfactory secured to panel

Cable HangingHardware

REF (A&B/PD10)

3 Alignment plate (C-121 Clip) perpanel Min. to maintain reveal with#6-5/8" PHWS factory provided,installed in field (by others) whencanopies are continuous.

Knife Edge

12" Reveal

Reinforcement Angle providedto prevent bowing attached

with 1/4-20 x 1/2" HH BoltFactory Installed into 1/4-20

Channel Nut with SpringREF (C/PD10)

These drawings show typical conditions for installing the CertainTeed Ceilings product shown. They should not be construed as a substitute for an architectural or engineering design and do not reflect the unique requirements of local codes, laws, statutes or regulations that may be applicable for a specific installtion. CertainTeed Ceilings assumes no liability forthe accuracy or completeness of the drawings for a specific installation or the fitness of the drawings for a particulat purpose. The user is advised to consult with local licenced design professionals in order to assure compliance with all legal requirements. CertainTeed Ceilings is not licenced to provide professional engineering or architectural services.

REPRESENTATIVE

CUSTOMER

SHEET TITLE

SHEET NO.

PROJECT TITLE

PRODUCT

DRWNDATE CHECK

PROJECT LOCATION

SHEET REFERENCE

02/24/21

7030FR Canopy

A.D. Z.D.

ARCHITECT

Only the products that are identified assuch on this document are FSC® certified

Cer

tain

Teed

Cei

ling

Cor

pora

tion

20 M

oore

s Roa

dM

alve

rn, P

A 1

9355

800-

233-

8990

Certificate Code:

SCS-COC-006960

R

FSC

The mark ofresponsible forestry

FSC C151918R

DA

TERE

VIS

ION

S#

Ceiling Flat Canopy

Suspension SystemInstallation

PD-11

APD-11

7030FR Isometric View (Knife Edge Panels Installation Guide)Scale: 3/4"=1'-0"

Page 7: Product Detail Set Contents: Ceiling Flat Canopy With

Cable HangingHardware

REF (A&B/PD10)

Trim Edge

12" Reveal

3 Alignment plate (C-121 Clip) perpanel Min. to maintain reveal with

#6-5/8" PHWS factory provided,installed in field (by others) when

canopies are continuous.

Optional factorysupplied black felt -installed in field

Reinforcement Angle providedto prevent bowing attached

with 1/4-20 x 1/2" HH BoltFactory Installed into 1/4-20

Channel Nut with SpringREF (C/PD10)

Pre-curved 7/8"x1-5/8" strutfactory secured to panel

These drawings show typical conditions for installing the CertainTeed Ceilings product shown. They should not be construed as a substitute for an architectural or engineering design and do not reflect the unique requirements of local codes, laws, statutes or regulations that may be applicable for a specific installtion. CertainTeed Ceilings assumes no liability forthe accuracy or completeness of the drawings for a specific installation or the fitness of the drawings for a particulat purpose. The user is advised to consult with local licenced design professionals in order to assure compliance with all legal requirements. CertainTeed Ceilings is not licenced to provide professional engineering or architectural services.

REPRESENTATIVE

CUSTOMER

SHEET TITLE

SHEET NO.

PROJECT TITLE

PRODUCT

DRWNDATE CHECK

PROJECT LOCATION

SHEET REFERENCE

02/24/21

7030FR Canopy

A.D. Z.D.

ARCHITECT

Only the products that are identified assuch on this document are FSC® certified

Cer

tain

Teed

Cei

ling

Cor

pora

tion

20 M

oore

s Roa

dM

alve

rn, P

A 1

9355

800-

233-

8990

Certificate Code:

SCS-COC-006960

R

FSC

The mark ofresponsible forestry

FSC C151918R

DA

TERE

VIS

ION

S#

Ceiling Flat Canopy

Suspension SystemInstallation

PD-12

APD-12

7030FR Isometric View (3/4" Trim Edge Panels Installation Guide)Scale: 3/4"=1'-0"

Page 8: Product Detail Set Contents: Ceiling Flat Canopy With

Cable HangingHardware

REF (A&B/PD10)

4" Trim Edge

Reinforcement Angle providedto prevent bowing attached

with 1/4-20 x 1/2" HH BoltFactory Installed into 1/4-20

Channel Nut with SpringREF (C/PD10)

Pre-curved 7/8"x1-5/8" strutfactory secured to panel

These drawings show typical conditions for installing the CertainTeed Ceilings product shown. They should not be construed as a substitute for an architectural or engineering design and do not reflect the unique requirements of local codes, laws, statutes or regulations that may be applicable for a specific installtion. CertainTeed Ceilings assumes no liability forthe accuracy or completeness of the drawings for a specific installation or the fitness of the drawings for a particulat purpose. The user is advised to consult with local licenced design professionals in order to assure compliance with all legal requirements. CertainTeed Ceilings is not licenced to provide professional engineering or architectural services.

REPRESENTATIVE

CUSTOMER

SHEET TITLE

SHEET NO.

PROJECT TITLE

PRODUCT

DRWNDATE CHECK

PROJECT LOCATION

SHEET REFERENCE

02/24/21

7030FR Canopy

A.D. Z.D.

ARCHITECT

Only the products that are identified assuch on this document are FSC® certified

Cer

tain

Teed

Cei

ling

Cor

pora

tion

20 M

oore

s Roa

dM

alve

rn, P

A 1

9355

800-

233-

8990

Certificate Code:

SCS-COC-006960

R

FSC

The mark ofresponsible forestry

FSC C151918R

DA

TERE

VIS

ION

S#

Ceiling Flat Canopy

Suspension System withPerimeter Trim Installation

PD-13

APD-13

7030FR Isometric View (4" Trim Edge Panels Installation Guide)Scale: 3/4"=1'-0"

Page 9: Product Detail Set Contents: Ceiling Flat Canopy With

These drawings show typical conditions for installing the CertainTeed Ceilings product shown. They should not be construed as a substitute for an architectural or engineering design and do not reflect the unique requirements of local codes, laws, statutes or regulations that may be applicable for a specific installtion. CertainTeed Ceilings assumes no liability forthe accuracy or completeness of the drawings for a specific installation or the fitness of the drawings for a particulat purpose. The user is advised to consult with local licenced design professionals in order to assure compliance with all legal requirements. CertainTeed Ceilings is not licenced to provide professional engineering or architectural services.

REPRESENTATIVE

CUSTOMER

SHEET TITLE

SHEET NO.

PROJECT TITLE

PRODUCT

DRWNDATE CHECK

PROJECT LOCATION

SHEET REFERENCE

02/24/21

7030FR Canopy

A.D. Z.D.

ARCHITECT

Only the products that are identified assuch on this document are FSC® certified

Cer

tain

Teed

Cei

ling

Cor

pora

tion

20 M

oore

s Roa

dM

alve

rn, P

A 1

9355

800-

233-

8990

Certificate Code:

SCS-COC-006960

R

FSC

The mark ofresponsible forestry

FSC C151918R

DA

TERE

VIS

ION

S#

Ceiling Concave Canopy

PD-14

Curved Wood Ceiling Panels - Square or rectangular boards orientedhorizontally. Includes independently suspended and lay-in panels.

Panel Width/Length: ± 0.062” (1/16”) Panel Thickness: ± 0.031” (1/32”)

Panel Squareness:Diagonals up to 60”

Diagonals over 60” to 120”± 0.062" (1/16")± 0.125" (1/8")

Cupping (deviation from flatness):At midpoint, diagonal to 60”

At midpoint, diagonal over 60”± 0.125 (1/8”)± 0.187 (3/16”)

Bowing (along edge):Along length up to 24”Along length 24” to 48”Along length 48” to 96”

± 0.062” (1/16”)± 0.125” (1/8”)

± 0.187” (3/16”)

Panel-to-Panel stepping (G) ± 0.062” (1/16”)

Arc Length (H)

Cord Length (H)

(G) = Installed allowance between panels(H) = Tolerances should be agreed upon between CertainTeed Ceilings &

Walls and the specifier during specification process.

CISCA Tolerances,Product Notes, andOrdering Notes

Ordering Notes:All dimensions are shown for reference and will have to bemodified for field installation. Dimensions are to be fieldverified prior to fabrication. Changes in dimensions mayresult in quantity adjustments. Closet stock and spares arenot included and must be added to quantity shown ifneeded. Utilize the use of cut-offs where appropriate -product quantities based on partial products being used.

Suspension System Components and Accessories:

CertainTeed 15/16" & 9/16"HD acoustical suspension systemssold separately.Visit www.certainteed.com/suspension-systems/ for moreinformation and purchasing options.

Installation Notes:Wood is a natural material with varying grain and colorcharacteristics, making each installation uniquelybeautiful. Characteristics may vary from panel to panel. Ifdesired, for greater visual consistency, the productsshould be laid out and arranged in advance ofinstallation to achieve the desired effect. All productsshould be reviewed before installation to avoidundesirable visual pattern because of natural color andgrain variations.

Wood panels must be acclimatized for 72 hours prior toinstallation. Maintain relative humidity between 25%and55% and temperature between 50°F and 86°F (10°C and30°C) for the life of the product, unless otherwise noted inorder, quote, and submittal documents. Fixtures and MEPdevices to be hung independently from ceiling supportsystem.

Fixtures and MEP devices may include but are not limitedto: light fixtures, HVAC diffusers, sprinkler heads and/orpiping, speakers, security cameras, components, décor,etc.

Reflected ceiling drawings will include penetrations oflimited light fixtures and HVAC registers only when the sizeof the wood is impacted. Other penetrations, includingbut not limited to sprinklers, security camerasaudio-visual, etc., Are typically not included in thedrawing set as placement and code requirements varyby product and jurisdiction.

Fixtures and MEP devices shown are for reference only;unless otherwise noted all fixtures and MEP devices byothers. Contractor to follow CISCA guidelines forsuspension system installation. Wood ceilings are typicallyheavier than other ceiling products. Follow manufacturerload requirements and installation specifications basedon the weights and dimensions of product beinginstalled.

All field cut products must be sealed with a clear sealeror stained then sealed.

See Product Detail Sets for edge condition details.