1/39 Shenzhen Ruik-tech Communication Co.,LTD. Web: Http://www.ruik-tech.com Tel:86+0755-23056383 Fax:86+0755-29071321 e-mail:[email protected]
Ruik-tech Communication (H.K.) CO.,LTD
Product Directory
Polarization maintaining components ---in line polarizer ---in line depolarizer ---polarization beam splitter/combiner ---polarization maintaining isolator ---polarization maintaining circulator ---polarization maintaining coupler ---polarization maintaining PLC splitter ---polarization maintaining CWDM ---polarization maintaining DWDM ---polarization maintaining FWDM ---polarization maintaining isolator FWDM ---polarization maintaining patchcord ---polarization maintaining optical switch ---polarization maintaining VOA High power components-polarization maintaining/polarization insensitive ---high power isolator ---high power circulator ---high power in line polarizer ---high power polarization beam splitter/combiner ---high power collimator ---high power collimated beam output isolator Hybrid components ---polarization maintaining tap isolator ---isolator polarization beam splitter/combiner ---polarization maintaining tap isolator FWDM ---polarization maintaining tap FWDM
2/39 Shenzhen Ruik-tech Communication Co.,LTD. Web: Http://www.ruik-tech.com Tel:86+0755-23056383 Fax:86+0755-29071321 e-mail:[email protected]
Ruik-tech Communication (H.K.) CO.,LTD
In-line Polarizer
Features Applications Low Insertion Loss Communication Systems High Return Loss Test Instrumentations High Extinction Ratio Fiber Sensor High Reliability Research High Stability Specifications Parameters Unit Value Center Wavelength nm 1310, 1550 1064 980 850 Operating Wavelength Range nm ±50 ±30 ±10 ±10 Typ.Insertion Loss at 23 ℃ dB 0.3 0.4 0.7 0.8 Max.Insertion Loss at 23℃ dB 0.5 0.6 0.9 1 Min.Return Loss dB 50 50 50 50 Typ.Extinction Ratio at 23℃ dB 30 30 28 28 Min.Extinction Ratio at 23℃ dB 28 28 25 25 Max.Optical Power(CW) mW 300 Max.Tensile Load N 5
PM1550 PM980 PM980 PM850 Fiber Type -
SMF-28E Hi1060 Hi1060 SM800 Operating Temperature ℃ -5~+70 Storage Temperature ℃ -40~+85 For device with connector, IL is 0.3dB higher, RL is 5dB lower, ER is 2dB lower; The default connector key is aligned to slow axis;
Package Dimensions
Ordering Information ILP-1111-2345-666
1111 -Center Wavelength: 1550=1550nm,1310=1310nm,......,0850=850nm 2 -Fiber type for input: 0=Panda fiber, 1=smf-28e, 2=hi1060, 3 -Fiber type for output: 0=Panda fiber, 1=smf-28e, 2=hi1060, 4 -Pigtail type: 0=250 bare fiber, 1=900um loose tube, 2=2.0mm loose tube, 3=3.0 loose tube 5 -Fiber length: 0=0.8m,1=1m
666 -Connector type: 0=FC/UPC,1=FC/APC,2=SC/UPC,3=SC/APC,4=LC/UPC,5=LC/APC
3/39 Shenzhen Ruik-tech Communication Co.,LTD. Web: Http://www.ruik-tech.com Tel:86+0755-23056383 Fax:86+0755-29071321 e-mail:[email protected]
Ruik-tech Communication (H.K.) CO.,LTD
2000nm In-line Polarizer
Features Applications Low Insertion Loss Optical Fiber Transducer High Return Loss Fiber Sensor High Extinction Ratio Optcal Fiber Gyro High Reliability Coherent Telecommunication Systems High Stability Specifications Parameters Unit Value Center Wavelength nm 2000 Operating Wavelength Range nm ±20 Max.Insertion Loss at 23℃ dB 1.0 Min.Return Loss dB 50 Min.Extinction Ratio at 23℃ dB 20 Max.Optical Power(CW) mW 500 Max.Tensile Load N 5 Fiber type - SMF-28E or SM1950 Operating Temperature ℃ -5~+70 Storage Temperature ℃ -40~+85 For device with connector, IL is 0.3dB higher, RL is 5dB lower, ER is 2dB lower; The default connector key is aligned to slow axis;
Package Dimensions
Ordering Information ILP-1111-2345-666
1111 -Center Wavelength: 2000=2000nm 2 -Fiber type for input: 0=Panda fiber, 1=smf-28e, 2=SM1950, 3 -Fiber type for output: 0=Panda fiber, 1=smf-28e, 2=SM1950, 4 -Pigtail type: 0=250 bare fiber, 1=900um loose tube, 2=2.0mm loose tube, 3=3.0 loose tube 5 -Fiber length: 0=0.8m,1=1m
666 -Connector type: 0=FC/UPC,1=FC/APC,2=SC/UPC,3=SC/APC,4=LC/UPC,5=LC/APC
4/39 Shenzhen Ruik-tech Communication Co.,LTD. Web: Http://www.ruik-tech.com Tel:86+0755-23056383 Fax:86+0755-29071321 e-mail:[email protected]
Ruik-tech Communication (H.K.) CO.,LTD
In-line Depolarizer
Features Applications Low Insertion Loss Communication Systems High Reliability Test Instrumentations High Stability Fiber Sensor Research Specifications Parameters Unit Value Center Wavelength nm 1310, 1550 1064 980 850 Operating Wavelength Range nm ±50 ±30 ±30 ±30 Typ. Insertion Loss at 23 ℃ dB 0.3 0.4 0.7 0.8 Max. Insertion Loss at 23℃ dB 0.5 0.6 0.9 1.0 Min. Return Loss dB 50 50 50 50 Max. Extinction Ratio at 23℃ dB 3 Max. Optical Power(CW) mW 500 Max. Tensile Load N 5 Fiber Type - PM1310 PM980 PM980 PM850 Operating Temperature ℃ -5~+70 Storage Temperature ℃ -40~+85 For device with connector, IL is 0.3dB higher, RL is 5dB lower; The default connector key is aligned to slow axis;
Package Dimensions
Ordering Information ILDP-1111-2345-666
1111 -Center Wavelength: 1550=1550nm,1310=1310nm,......,0850=850nm 4 -Pigtail type: 0=250 bare fiber, 1=900um loose tube, 2=2.0mm loose tube, 3=3.0 loose tube 5 -Fiber length: 0=0.8m,1=1m
666 -Connector type: 0=FC/UPC,1=FC/APC,2=SC/UPC,3=SC/APC,4=LC/UPC,5=LC/APC
5/39 Shenzhen Ruik-tech Communication Co.,LTD. Web: Http://www.ruik-tech.com Tel:86+0755-23056383 Fax:86+0755-29071321 e-mail:[email protected]
Ruik-tech Communication (H.K.) CO.,LTD
1x2 Polarization Beam Combiner/Splitter
Features Applications Low Insertion Loss Optical Fiber Transducer High Return Loss Fiber Sensor High Extinction Ratio Optcal Fiber Gyro High Reliability Coherent Telecommunication Systems High Stability Specifications Parameters Unit Values Grade - P A P A Center Wavelength nm 1310,1550 1064,980 Operating Wavelength Range nm ±40 ±20 Typ.Insertion Loss at 23 ℃ dB 0.4 0.5 0.6 0.7 Max.Insertion Loss at 23℃ dB 0.6 0.7 0.8 0.9 Min.Extinction Ratio at 23℃ dB 22 20 22 20 Directivity dB 50 Min.Return Loss dB 50 Max.Optical Power(CW) mW 300 Max.Tensile Load N 5
Port1 & 2 PM Panda Fiber Fiber Type
Port3 -
SMF-28e, HI1060 or PM Panda fiber Operating temperature ℃ -5~+70 Storage temperature ℃ -40~+85 For device with connector, IL is 0.3dB higher, RL is 5dB lower, ER is 2dB lower; The default connector key is aligned to slow axis;
Package Dimensions
Ordering Information PBC/S-11-23456-777
1111 -Center Wavelength: 1550=1550nm,1310=1310nm,......,850=850nm 2 -Grade: P=Perfect grade, A=A grade 3 -Fiber type for Port 3: 1=Panda fiber aligned to Port1,2=smf-28e,3=hi1060,4=Panda fiber 45°aligned to Port1 4 -Fiber type for Port 1=Panda fiber, 2=smf-28e,3=hi1060 5 -Pigtail type: 0=250 bare fiber, 1=900um loose tube, 2=2.0mm loose tube, 3=3.0 loose tube 6 -Fiber length: 0=0.8m,1=1m
777 -Connector type: 0=FC/UPC,1=FC/APC,2=SC/UPC,3=SC/APC,4=LC/UPC,5=LC/APC
6/39 Shenzhen Ruik-tech Communication Co.,LTD. Web: Http://www.ruik-tech.com Tel:86+0755-23056383 Fax:86+0755-29071321 e-mail:[email protected]
Ruik-tech Communication (H.K.) CO.,LTD
1360 &1450nm 1x2 Polarization Beam Combiner/Splitter
Features Applications Low Insertion Loss Optical Fiber Transducer High Return Loss Fiber Sensor High Extinction Ratio Optcal Fiber Gyro High Reliability Coherent Telecommunication Systems High Stability Specifications Parameters Unit Values Grade - P Center Wavelength nm 1360, 1450 Operating Wavelength Range nm ±30 Typ.Insertion Loss at 23 ℃ dB 0.7 Max.Insertion Loss at 23℃ dB 1.0 Min.Extinction Ratio at 23℃ dB 22 Directivity dB 50 Min.Return Loss dB 50 Max.Optical Power(CW) mW 300 Max.Tensile Load N 5
Port1 & 2 PM Panda Fiber Fiber Type
Port3 -
SMF-28e or PM Panda fiber Operating temperature ℃ -5~+70 Storage temperature ℃ -40~+85 For device with connector, IL is 0.3dB higher, RL is 5dB lower, ER is 2dB lower; The default connector key is aligned to slow axis;
Package Dimensions
Ordering Information PBC/S-1111-23456-777
1111 -Center Wavelength: 1450=1450nm,1360=1360nm 2 -Grade: P=Perfect grade 3 -Fiber type for Port 3: 1=Panda fiber aligned to Port1,2=smf-28e,3=Panda fiber 45°aligned to Port1 4 -Fiber type for Port 1=Panda fiber, 2=smf-28e 5 -Pigtail type: 0=250 bare fiber, 1=900um loose tube, 2=2.0mm loose tube, 3=3.0 loose tube 6 -Fiber length: 0=0.8m,1=1m
777 -Connector type: 0=FC/UPC,1=FC/APC,2=SC/UPC,3=SC/APC,4=LC/UPC,5=LC/APC
7/39 Shenzhen Ruik-tech Communication Co.,LTD. Web: Http://www.ruik-tech.com Tel:86+0755-23056383 Fax:86+0755-29071321 e-mail:[email protected]
Ruik-tech Communication (H.K.) CO.,LTD
1410nm 1x2 Polarization Beam Combiner/Splitter
Features Applications Low Insertion Loss Optical Fiber Transducer High Return Loss Fiber Sensor High Extinction Ratio Optcal Fiber Gyro High Reliability Coherent Telecommunication Systems High Stability Specifications Parameters Unit Values Grade - P Center Wavelength nm 1410 Operating Wavelength Range nm ±70 Typ.Insertion Loss at 23 ℃ dB 0.9 Max.Insertion Loss at 23℃ dB 1.1 Min.Extinction Ratio at 23℃ dB 20 Directivity dB 50 Min.Return Loss dB 50 Max.Optical Power(CW) mW 300 Max.Tensile Load N 5
Port1 & 2 PM Panda Fiber Fiber Type
Port3 -
SMF-28e or PM Panda fiber Operating temperature ℃ -5~+70 Storage temperature ℃ -40~+85 For device with connector, IL is 0.3dB higher, RL is 5dB lower, ER is 2dB lower; The default connector key is aligned to slow axis;
Package Dimensions
Ordering Information PBC/S-1111-23456-777
1111 -Center Wavelength: 1410=1410nm 2 -Grade: P=Perfect grade 3 -Fiber type for Port 3: 1=Panda fiber aligned to Port1,2=smf-28e,3=Panda fiber 45°aligned to Port1 4 -Fiber type for Port 1=Panda fiber, 2=smf-28e 5 -Pigtail type: 0=250 bare fiber, 1=900um loose tube, 2=2.0mm loose tube, 3=3.0 loose tube 6 -Fiber length: 0=0.8m,1=1m
777 -Connector type: 0=FC/UPC,1=FC/APC,2=SC/UPC,3=SC/APC,4=LC/UPC,5=LC/APC
8/39 Shenzhen Ruik-tech Communication Co.,LTD. Web: Http://www.ruik-tech.com Tel:86+0755-23056383 Fax:86+0755-29071321 e-mail:[email protected]
Ruik-tech Communication (H.K.) CO.,LTD
Polarization Maintaining Isolator(1310,1480,1550)
Features Applications Low Insertion Loss Communication Systems High Return Loss Test Instrumentations High Extinction Ratio Fiber Sensor High Isolation Research High Stability & Reliability Specifications Parameter Unit Value Stage - Single Dual Grade - P A P A Center Wavelength nm 1310,1480,1550 Operating Wavelength Range nm ±20 Typ. Peak Isolation at 23℃ dB 42 40 58 55 Min. Isolation at 23℃ dB 28 26 48 45 Typ.Insertion Loss at 23℃ dB 0.4 0.5 0.5 0.6 Max.Insertion Loss at 23℃ dB 0.55 0.65 0.65 0.8 Min.Extinction Ratio(only for B type) dB 20 18 20 18 Min.Extinction Ratio(only for F type) dB 25 23 25 23 Min.Return Loss (input/output) dB 50/50 Max.Optical Power(CW) mW 500 Max.Tensile Load N 5 Fiber Type - PM Panda Fiber Operating Temperature ℃ -5~+70 Storage Temperature ℃ -40~+85 For device with connector, IL is 0.3dB higher, RL is 5dB lower, ER is 2dB lower; The default connector key is aligned to slow axis;
Package Dimensions
Ordering Information PMIS-1111-23456-77
1111 -Center wavelength: 1550=1550nm, 1480=1480nm, 1310=1310nm...... 2 -Grade: P=P garde, A=A grade 3 -Stage: S=Single-core stage, D=Dual-core stage 4 -Axis alignment F=Slow axis working Fast axis blocked, B=Both of axis working 5 -Pigtail type: 0=250 bare fiber, 1=900um loose tube, 2=2.0mm loose tube, 3=3.0 loose tube 6 -Fiber length: 0=0.8m,1=1m
77 -Connector type: 0=FC/UPC,1=FC/APC,2=SC/UPC,3=SC/APC,4=LC/UPC,5=LC/APC
9/39 Shenzhen Ruik-tech Communication Co.,LTD. Web: Http://www.ruik-tech.com Tel:86+0755-23056383 Fax:86+0755-29071321 e-mail:[email protected]
Ruik-tech Communication (H.K.) CO.,LTD
Polarization Maintaining Isolator(1064nm)
Features Applications Low Insertion Loss Communication Systems High Return Loss Test Instrumentations High Extinction Ratio Fiber Sensor High Isolation Research High Stability & Reliability Specifications Parameter Unit Value Stage - Single Dual Grade - P A P A Center Wavelength nm 1064 Operating Wavelength Range nm ±5 Typ.Peak Isolation dB 40 38 55 52 Min.Isolation at 23℃ dB 35 32 45 42 Typ.Insertion Loss at 23℃ dB 1.5 1.6 2.4 2.6 Max.Insertion Loss at 23℃ dB 1.8 2.2 3.2 3.4 Min.Return Loss (input/output) dB 50/50 50/50 50/50 50/50 Min.Extinction Ratio(only for B type) dB 20 18 20 18 Min.Extinction Ratio(only for F type) dB 22 20 22 20 Max.Optical Power(CW) mW 300 Max.Tensile Load N 5 Fiber Type - PM Panda Fiber Operating Temperature ℃ -5~+50 Storage Temperature ℃ -40~+85 For device with connector, IL is 0.3dB higher, RL is 5dB lower, ER is 2dB lower; The default connector key is aligned to slow axis;
Package Dimensions
Ordering Information PMIS-1064-23456-777
1064 -Center Wavelength: 1064=1064nm 2 -Grade: P=P garde, A=A grade 3 -Stage: S=Single-core stage, D=Dual-core stage 4 -Axis alignment F=Slow axis working Fast axis blocked, B=Both of axis working 5 -Pigtail type: 0=250 bare fiber, 1=900um loose tube, 2=2.0mm loose tube, 3=3.0 loose tube 6 -Fiber length: 0=0.8m,1=1m
777 -Connector type: 0=FC/UPC,1=FC/APC,2=SC/UPC,3=SC/APC,4=LC/UPC,5=LC/APC
10/39 Shenzhen Ruik-tech Communication Co.,LTD. Web: Http://www.ruik-tech.com Tel:86+0755-23056383 Fax:86+0755-29071321 e-mail:[email protected]
Ruik-tech Communication (H.K.) CO.,LTD
2000nm Polarization Maintaining Isolator
Features Applications Low Insertion Loss EDFA Low Polarization Dependent Loss Testing Instrumentations High Return Loss Transmitters High Isolation Fiber Laser High stability & Reliability WDM System Specifications Parameter Unit Value Stage - Single Dual Center Wavelength nm 2000 Bandwidth nm ±30 Min.Isolation at 23℃ dB 20 30 Max. Insertion Loss at 23℃ dB 1.3 1.6 Max.Extinction Ratio dB 20 20 Min.Return Loss dB 50/45 Max.Optical Power(CW) mW 500 Max.Tensile Load N 5 Fiber Type - Panda Fiber or Nufern Fiber Operating Temperature ℃ -5~+70 Storage Temperature ℃ -40~+85 For device with connector, IL is 0.3dB higher, RL is 5dB lower;
Package Dimensions
Ordering Information PMIS-1111-2345-66
1111 -Center wavelength: 2000=2000nm...... 2 -Stage: S=Single-core stage, D=Dual-core stage 3 -Fiber type 0=Panda PM 125/250 Fiber,1=Nufern PM1950 Fiber,S=Specify 4 -Pigtail type: 0=250 bare fiber, 1=900um loose tube, 2=2.0mm loose tube, 3=3.0 loose tube 5 -Fiber length: 0=0.8m,1=1m
66 -Connector type: 0=FC/UPC,1=FC/APC,2=SC/UPC,3=SC/APC,4=LC/UPC,5=LC/APC
11/39 Shenzhen Ruik-tech Communication Co.,LTD. Web: Http://www.ruik-tech.com Tel:86+0755-23056383 Fax:86+0755-29071321 e-mail:[email protected]
Ruik-tech Communication (H.K.) CO.,LTD
1x2 Polarization Maintaining Optical Circulator(Fast axis blocked)
Features Applications Low Insertion Loss EDFA & Raman Amplifier High Return Loss Fiber Sensor High Isolation Fiber Instrument High Extinction Ratio Specifications Parameter Unit Value Type - Type A Type B Center Wavelength nm 1310& 1550 1310 &1550 1064 Operating Wavelength Range nm ±30 ±20 ±5 Typ.Peak Isolation 23℃ dB 46 30 30 Min.Isolation at 23℃ dB 40 20 25 Typ.Insertion Loss at 23℃ dB 0.7 0.6 1.8 Max.Insertion Loss at 23℃ dB 0.9 0.8 2.1 Min.Extinction Ratio dB 22 20 20 Min.Cross Talk dB 50 Min.Return Loss dB 50 Max.Optical Power(CW) mW 300 Max.Tensile Load N 5 Fiber Type - PM Panda Fiber Operating Temperature ℃ -5~+70 Storage Temperature ℃ -40~+85 For device with connector, IL is 0.3dB higher, RL is 5dB lower, ER is 2dB lower; The default connector key is aligned to slow axis;
Package Dimensions
Ordering Information PMCIR-1111-23456-777
1111 -Center wavelength: 1550=1550nm,1310=1310nm,......,0850=850nm 2 -Port type: 3=3-Port, 4=4-Port 3 -Stage: A=A grade, B=B grade 4 -Axis alignment: F=Slow axis working, Fast axis blocked 5 -Pigtail type: 0=250 bare fiber, 1=900um loose tube, 2=2.0mm loose tube, 3=3.0 loose tube 6 -Fiber length: 0=0.8m,1=1m
777 -Connector type: 0=FC/UPC,1=FC/APC,2=SC/UPC,3=SC/APC,4=LC/UPC,5=LC/APC
12/39 Shenzhen Ruik-tech Communication Co.,LTD. Web: Http://www.ruik-tech.com Tel:86+0755-23056383 Fax:86+0755-29071321 e-mail:[email protected]
Ruik-tech Communication (H.K.) CO.,LTD
1x2 Polarization Maintaining Optical Circulator(Both axis working)
Features Applications Low Insertion Loss EDFA & Raman Amplifier High Return Loss Fiber Sensor High Isolation Fiber Instrument High Extinction Ratio High Reliability& Stability Specifications Parameters Unit Values Grade - P A Center Wavelength nm 1310, 1550 Bandwidth nm ±30 Peak Isolation at 23℃ dB 50 Min.Isolation at 23℃ dB 40 Typ.Insertion Loss at 23℃ dB 0.6 0.8 Max.Insertion Loss at 23℃ dB 0.8 1.0 Min.Extinction Ratio dB 22 Min.Return Loss dB 50 Min.Directivity dB 50 Power Handling mW 300 Fiber Type - SM Panda fiber Operating Temperature ℃ 0~+60 Storage Temperature ℃ -40~+85 For device with connector, IL is 0.3dB higher, RL is 5dB lower, ER is 2dB lower; The default connector key is aligned to slow axis;
Package Dimensions
Ordering Information PMCIR-1111-2345-666
1111 -Center wavelength: 1550=1550nm,1310=1310nm,......,0850=850nm 2 -Grade: P=Perfect, A=A grade 3 -Axis alignment: B=Both axis working 4 -Pigtail type: 0=250 bare fiber, 1=900um loose tube, 2=2.0mm loose tube, 3=3.0 loose tube 5 -Fiber length: 0=0.8m,1=1m
666 -Connector type: 0=FC/UPC,1=FC/APC,2=SC/UPC,3=SC/APC,4=LC/UPC,5=LC/APC
13/39 Shenzhen Ruik-tech Communication Co.,LTD. Web: Http://www.ruik-tech.com Tel:86+0755-23056383 Fax:86+0755-29071321 e-mail:[email protected]
Ruik-tech Communication (H.K.) CO.,LTD
2x2 Polarization Maintaining Optical Circulator(Fast axis blocked)
Features Applications Low Insertion Loss EDFA & Raman Amplifier High Return Loss Fiber Sensor High Isolation Fiber Instrument High Extinction Ratio High Reliability& Stability Specifications Parameter Unit Value Type - Type A Type B Center Wavelength nm 1310& 1550 1310 &1550 1064 Operating Wavelength Range nm ±30 ±20 ±5 Typ.Peak Isolation 23℃ dB 50 30 30 Min.Isolation at 23℃ dB 40 20 28 Typ.Insertion Loss at 23℃ dB 0.8 0.7 2.1 Max.Insertion Loss at 23℃ dB 1.1 1.0 2.8 Min.Extinction Ratio dB 20 20 20 Min.Cross Talk dB 50 Min.Return Loss dB 50 Max.Optical Power(CW) mW 300 Max.Tensile Load N 5 Fiber Type - PM Panda Fiber Operating Temperature ℃ -5~+70 Storage Temperature ℃ -40~+85 For device with connector, IL is 0.3dB higher, RL is 5dB lower, ER is 2dB lower; The default connector key is aligned to slow axis;
Package Dimensions
Ordering Information PMCIR-1111-23456-7777
1111 -Center wavelength: 1550=1550nm,1310=1310nm,......,0850=850nm 2 -Port type: 3=3-Port, 4=4-Port 3 -Stage: A=A grade, B=B grade 4 -Axis alignment: F=Slow axis working, Fast axis blocked 5 -Pigtail type: 0=250 bare fiber, 1=900um loose tube, 2=2.0mm loose tube, 3=3.0 loose tube 6 -Fiber length: 0=0.8m,1=1m
7777 -Connector type: 0=FC/UPC,1=FC/APC,2=SC/UPC,3=SC/APC,4=LC/UPC,5=LC/APC
14/39 Shenzhen Ruik-tech Communication Co.,LTD. Web: Http://www.ruik-tech.com Tel:86+0755-23056383 Fax:86+0755-29071321 e-mail:[email protected]
Ruik-tech Communication (H.K.) CO.,LTD
Polarization Maintaining Filter Coupler(fast axis blocked)
Features Applications Low Insertion Loss EDFA & Raman Amplifier High Return Loss Fiber Sensor High Extinction Ratio Fiber Optical Instrument High Reliability Power Monitoring System High Stability Specifications Parameter Unit Value Type - 1x2 2x2 Center Wavelength nm 1310,1550 1064 1310,1550 1064 Operating Wavelength Range nm ±40 ±20 ±40 ±20 Excess Loss dB 0.7 0.8 1.0 1.2 Uniformity (only for 50/50) dB 0.4 0.5 0.6 0.8 Coupling Ratio dB 01/99~50/50 Min. Extinction Ratio only for F type dB 22 22 22 22 Min.Return Loss dB 50 Max.Optical Power(CW) mW 300 Max.Tensile Load N 5
Tap Port - SMF-28e, HI1060 or PM Panda Fiber Fiber Type Port 1 & 3 - PM Panda Fiber
Operating Temperature ℃ -5~+70 Storage Temperature ℃ -40~+85 For device with connector, IL is 0.3dB higher, RL is 5dB lower, ER is 2dB lower; The default connector key is aligned to slow axis; For Type 1x2, routing path is 3 to 1,2(tap). For Type 2x2, routing path is 1 to 3, 4(tap), 3 to 1, 2(tap)
Package Dimensions
Ordering Information
PMFC-1111-23345678-9999 1111 -Center wavelength: 1550=1550nm,1310=1310nm,......,0850=850nm
2 -Port number: 1=1x2, 2=2x2 33 -Tap ratio: 01=1%,02=2%,......,05=5%,......, 50=50%
4 -Axis alignment F=Slow axis working Fast axis blocked, B=Both of axis working 5 -Fiber type for tap 1=PM Panda fiber aligned, 2=smf-28e, 3=hi1060 6 -Fiber type for port 1=PM Panda fiber, 2=SMF-28e,3=Hi1060 7 -Pigtail type: 0=250 bare fiber, 1=900um loose tube, 2=2.0mm loose tube, 3=3.0 loose tube 8 -Fiber length: 0=0.8m,1=1m
9999 -Connector type: 0=FC/UPC,1=FC/APC,2=SC/UPC,3=SC/APC,4=LC/UPC,5=LC/APC
15/39 Shenzhen Ruik-tech Communication Co.,LTD. Web: Http://www.ruik-tech.com Tel:86+0755-23056383 Fax:86+0755-29071321 e-mail:[email protected]
Ruik-tech Communication (H.K.) CO.,LTD
Polarization Maintaining Filter Coupler(both axis working)
Features Applications Low Insertion Loss EDFA & Raman Amplifier High Return Loss Fiber Sensor High Extinction Ratio Fiber Optical Instrument High Reliability Power Monitoring System High Stability Specifications Parameter Unit Value Type - 1x2 2x2 Center Wavelength nm 1310,1550 1064 1310,1550 1064 Operating Wavelength Range nm ±40 ±20 ±40 ±20 Excess Loss dB 0.7 0.8 1.0 1.2 Uniformity (only for 50/50) dB 0.4 0.5 0.6 0.8 Coupling Ratio dB 01/99~50/50 Min.Extinction Ratio only for B type dB 20 20 18 18 Min.Return Loss dB 50 Max.Optical Power(CW) mW 300 Max.Tensile Load N 5
Tap Port - SMF-28e, HI1060 or PM Panda Fiber Fiber Type Port 1 & 3 - PM Panda Fiber
Operating Temperature ℃ -5~+70 Storage Temperature ℃ -40~+85 For device with connector, IL is 0.3dB higher, RL is 5dB lower, ER is 2dB lower; The default connector key is aligned to slow axis; For Type 1x2, routing path is 3 to 1, 2(tap), For Type 2x2, routing path is 1 to 2(tap), 4, 3 to 4(tap), 2 Package Dimensions
Ordering Information PMFC-1111-23345678-9999
1111 -Center wavelength: 1550=1550nm,1310=1310nm,......,0850=850nm 2 -Port number: 1=1x2, 2=2x2
33 -Tap ratio: 01=1%,02=2%,......,05=5%,......, 50=50% 4 -Axis alignment F=Slow axis working Fast axis blocked, B=Both of axis working 5 -Fiber type for tap 1=PM Panda fiber aligned, 2=smf-28e, 3=hi1060 6 -Fiber type for port 1=PM Panda fiber, 2=SMF-28e,3=Hi1060 7 -Pigtail type: 0=250 bare fiber, 1=900um loose tube, 2=2.0mm loose tube, 3=3.0 loose tube 8 -Fiber length: 0=0.8m,1=1m
9999 -Connector type: 0=FC/UPC,1=FC/APC,2=SC/UPC,3=SC/APC,4=LC/UPC,5=LC/APC
16/39 Shenzhen Ruik-tech Communication Co.,LTD. Web: Http://www.ruik-tech.com Tel:86+0755-23056383 Fax:86+0755-29071321 e-mail:[email protected]
Ruik-tech Communication (H.K.) CO.,LTD
PM PLC Splitter Module
Features Applications Low Insertion Loss EDFA & Raman Amplifier High Return Loss Fiber Sensor High Extinction Ratio Fiber Optical Instrument High Reliability Power Monitoring System High Stability Specifications Parameter Unit Value Type - 1x4 1x8 1x16 Center Wavelength nm 1520-1570 Max. Insertion Loss dB 7.3 10.5 13.7 Min.WDL dB 0.6 0.6 1.0 Uniformity dB 0.6 0.8 1.2 Min. Extinction Ratio Both of axis working dB 18 Min. Return Loss dB 50 Directivity dB 55 Temperature Stability(-40~85 ℃)(dB) dB 0.5 Max. Optical Power(CW) mW 300 Max. Tensile Load N 5 Fiber Type - PM Panda Fiber Operating Temperature ℃ -5~+70 Storage Temperature ℃ -40~+85 Package Dimensions mm 100x80x10 100x80x10 120x80x18 For device with connector, IL is 0.3dB higher, RL is 5dB lower, ER is 2dB lower; The default connector key is aligned to slow axis; Package Dimensions
Ordering Information PMPLCM-1111-2345-66
1111 -Center Wavelength: 5257=1520-1570nm 2 -Port Number: 2=1x2, 4=1x4,......, 8=1x8,........ 3 -Axis Alignment: F=Slow axis working, Fast axis blocked, B=Both axis working 4 -Pigtail type: 0=250 bare fiber, 1=900um loose tube, 2=2.0mm loose tube, 3=3.0 loose tube 5 -Fiber length: 0=0.8m,1=1m
66 -Connector type: 0=FC/UPC,1=FC/APC,2=SC/UPC,3=SC/APC,4=LC/UPC,5=LC/APC
17/39 Shenzhen Ruik-tech Communication Co.,LTD. Web: Http://www.ruik-tech.com Tel:86+0755-23056383 Fax:86+0755-29071321 e-mail:[email protected]
Ruik-tech Communication (H.K.) CO.,LTD
1 x 2 PM Coarse Wavelength Division Multiplexer
Features Applications Low Insertion Loss CWDM System High Return Loss CWDM/OADM Module High Channel Isolation CWDM/OADM Networks Wide Transmission Width High Reliability & Stability Specifications Parameters Unit Values Central Wavelength nm ITU or ITU+1 Operating Wavelength nm 1260~1460 or 1460~1620 or 1260~1620 Channel Space nm 20 Min.Channel Bandwidth@λc nm ± 6.5 Max.Channel Flatness dB 0.4
Transmission Channel dB 0.6 Max.Insertion Loss Reflection Channel dB 0.4 (1260~1460 or 1460~1620) or 0.6(1260~1620) Adjacent channel dB 30 Non-adjacent channel dB 40 Min.Isolation Reflection Channel dB 12
Directivity dB 55 Min.Return Loss dB 50 Min.Extinction Ratio dB 18 Max.Wavelength thermal stability nm/℃ 0.003 Max.Insertion loss thermal stability dB/℃ 0.005 Max.Power handling mW 500 Operating Temperature ℃ 0~+70 Storage Temperature ℃ -40~+85 For device with connector, IL is 0.3dB higher, RL is 5dB lower, ER is 2dB lower; The default connector key is aligned to slow axis;
Package Dimensions
Ordering Information PMCWDM-22-34567-888
22 -Center wavelength: 27=1270nm or 1271nm, ......,55=1550 or1551nm,......,61=1610nm or1611nm 3 -Operating wavelength: F=Full wave(1260nm~1620nm), H=half wave(1260~1460 or 1460~1620) 4 -Port type: 1=1x1, 2=1x2 5 -Fiber type 1=PM Panda fiber 6 -Pigtail type: 0=250 bare fiber, 1=900um loose tube, 2=2.0mm loose tube, 3=3.0 loose tube 7 -Fiber length: 0=0.8m,1=1m
888 -Connector type: 0=FC/UPC,1=FC/APC,2=SC/UPC,3=SC/APC,4=LC/UPC,5=LC/APC
Ruik-tech Communication (H.K.) CO.,LTD
18/39 Shenzhen Ruik-tech Communication Co.,LTD. Web: Http://www.ruik-tech.com Tel:86+0755-23056383 Fax:86+0755-29071321 e-mail:[email protected]
Ruik-tech Communication (H.K.) CO.,LTD
Polarization Maintaining Dense WDM
Features Applications Low Insertion Loss DWDM Module High Return Loss DWDM System High Isolation Pon Networks High Reliability & Stability CATV Links Specifications Parameters Unit Values Channel Space Ghz 100 200 Center Wavelength nm ITU Grid Center Wavelength Accuracy nm ±0.05 0.01 Channel Pass band (@-0.5dB) nm 0.22 0.5 Max. Insertion Loss of Transmission Channel dB 1.0 0.9 Max. Insertion Loss of Reflection Channel dB 0.4 0.4 Min. Transmission Isolation @Reflection Wavelength dB 30 30 Min. Reflection Isolation @Transmission Wavelength dB 10 10 Max. Channel Flatness dB 0.3 Min. Extinction Ratio dB 18 Max. Wavelength thermal stability nm/℃ 0.003 Max. Insertion loss thermal Stability dB/℃ 0.005 Min. Return Loss N 50 Max. Power Handling (CW) mW 300 Fiber Type - PM Panda fiber Operating Temperature ℃ 0~+70 Storage Temperature ℃ -40~+85 For device with connector, IL is 0.3dB higher, RL is 5dB lower, ER is 2dB lower; The default connector key is aligned to slow axis;
Package Dimensions Ordering Information
PMDWDM-11-2345-666 11 -Center wavelength: 26=26CH,27=27CH,......, 40=40CH, 41=41CH,......
2 -Port type: 1=1x1, 2=1x2 3 -Channel space: 1=100G, 2=200G 5 -Fiber type 1=PM Panda fiber 4 -Pigtail type: 0=250 bare fiber, 1=900um loose tube, 2=2.0mm loose tube, 3=3.0 loose tube 5 -Fiber length: 0=0.8m,1=1m
666 -Connector type: 0=FC/UPC,1=FC/APC,2=SC/UPC,3=SC/APC,4=LC/UPC,5=LC/APC
19/39 Shenzhen Ruik-tech Communication Co.,LTD. Web: Http://www.ruik-tech.com Tel:86+0755-23056383 Fax:86+0755-29071321 e-mail:[email protected]
Ruik-tech Communication (H.K.) CO.,LTD
PM Coarse WDM Module
Features Applications Low Insertion Loss CWDM System High Return Loss Pon Networks High Channel Isolation CATV Links Good Channel to Channel Uniformity High Reliability & Stability Specifications Parameters Unit Values Channel Number 1x2 1x4 1x8 1x16 Central Wavelength nm ITU or ITU+1 Operating Wavelength nm 1260~1460 or 1460~1620 or 1260~1620 Channel Space nm 20 Min. Channel Bandwidth @ λ c nm ± 6.5 Max. Channel Flatness dB 0.4 Max. Insertion Loss Mux to Demux(Link) dB 1.2 1.9 2.7 4.2
Adjacent channel dB 30 30 30 30 Non-adjacent channel dB 45 45 45 45 Min. Isolation Upgrade Channel dB 12 12 12 12
Min. Return Loss dB 50 Min. Extinction Ratio dB 16 Max. Wavelength thermal stability nm/℃ 0.003 Max. Insertion loss thermal stability dB/℃ 0.005 Max. Power handling mW 500 Operating Temperature ℃ 0~+70 Storage Temperature ℃ -40~+85 For device with connector, IL is 0.3dB higher, RL is 5dB lower, ER is 2dB lower; The default connector key is aligned to slow axis;
Package Dimensions
Ordering Information PMCMM-234455-6789A
2 -Module Type: M=Mux, D=Demux 3 -Operating wavelength: F=Full wave(1260nm~1620nm), H=half wave(1260~1460 or 1460~1620)
44 -Intial wavelength: 27=1270nm or 1271nm, ......,55=1550 or1551nm,......,61=1610nm or1611nm 55 -Port type: 1=1x1, 2=1x2, 16=1x16
6 -Fiber type 1=PM Panda fiber 7 -Pigtail type: 0=250 bare fiber, 1=900um loose tube, 2=2.0mm loose tube, 3=3.0 loose tube 8 -Fiber length: 0=0.8m,1=1m 9 -Package Type S=ABS Box:100x80x10mm M=ABS Box:120x80x18mm,......, 19=19” 1U Rack-Mount A -Connector type: 0=FC/UPC,1=FC/APC,2=SC/UPC,3=SC/APC,4=LC/UPC,5=LC/APC
Ruik-tech Communication (H.K.) CO.,LTD
20/39 Shenzhen Ruik-tech Communication Co.,LTD. Web: Http://www.ruik-tech.com Tel:86+0755-23056383 Fax:86+0755-29071321 e-mail:[email protected]
Ruik-tech Communication (H.K.) CO.,LTD
PM Dense WDM Module
Features Applications Low Insertion Loss DWDM System High Return Loss Pon Networks High Channel Isolation CATV Links Good Channel to Channel Uniformity Specifications Parameters Unit Values Channel Number 1x2 1x4 1x8 1x16 Central Wavelength nm ITU Channel Space Ghz 100 or 200 Center Wavelength Accuracy nm 100G:±0.05 / 200G: ±0.1 Channel Pass band (@-0.5dB) nm 100G:0.22 / 200G:0.5 Max. Insertion Loss Mux to Demux(Link) dB 2.0 2.6 3.7 5.0
Adjacent channel dB 30 30 30 30 Non-adjacent channel dB 40 40 40 40 Min. Isolation Upgrade Channel dB 10 10 10 10
Max. Channel Flatness dB 0.3 Min. Return Loss dB 50 Min. Extinction Ratio dB 16 Max. Wavelength thermal stability nm/℃ 0.003 Max. Insertion loss thermal stability dB/℃ 0.005 Max. Power handling mW 500 Operating Temperature ℃ 0~+70 Storage Temperature ℃ -40~+85 The default connector key is aligned to slow axis; For device with connector, IL is 0.3dB higher, ER is 2dB lower, RL is 5dB lower;
Package Dimensions
Ordering Information PMDMM-234455-6789A
2 -Module Type: M=Mux, D=Demux 3 -Channel space: 1=100G, 2=200G
44 -intial wavelength: 26=26CH, 27=27CH,......, 40=40CH, 41=41CH,...... 55 -Port type: 01=1x1,02=1x2, 16=1x16
6 -Fiber type 1=PM Panda fiber 7 -Pigtail type: 0=250 bare fiber, 1=900um loose tube, 2=2.0mm loose tube, 3=3.0 loose tube 8 -Fiber length: 0=0.8m,1=1m 9 -Package Type S=ABS Box:100x80x10mm M=ABS Box:120x80x18mm,......, 9=19” 1U Rack-Mount A -Connector type: 0=FC/UPC,1=FC/APC,2=SC/UPC,3=SC/APC,4=LC/UPC,5=LC/APC
Ruik-tech Communication (H.K.) CO.,LTD
21/39 Shenzhen Ruik-tech Communication Co.,LTD. Web: Http://www.ruik-tech.com Tel:86+0755-23056383 Fax:86+0755-29071321 e-mail:[email protected]
Ruik-tech Communication (H.K.) CO.,LTD
Polarization Maintaining Filter WDM
Features Applications Low Insertion Loss CATV System High Return Loss CWDM/DWDM Module High Reliability & Stability Pon Networks Specifications Parameters Unit Values Type nm 1064/980 1550/980 1550/1064 1550/1480 Transmission Wavelength nm 1020~1080 1520~1580 1520~1580 1535~1565 Reflection Wavelength nm 960~990 960~990 1020~1080 1480±10 Max.Insertion Loss of Transmission Channel dB 0.8 0.7 0.8 0.8 Max.Insertion Loss of Reflection Channel dB 0.6 0.5 0.6 0.6 Min.Transmissionl Isolation@Reflection Wavelength dB 25 30 25 25 Min.Reflection Isolation@Transmission Wavelength dB 12 15 12 12 Max.Channel Flatness dB 0.4 Min.Extinction Ratio at 23℃ dB 18 Max.Wavelength thermal stability nm/℃ 0.003 Max.Insertion loss thermal Stability dB/℃ 0.005 Min.Return Loss N 50 Max.Power Handling (CW) mW 300 Fiber Type - PM Panda fiber Operating Temperature ℃ 0~+70 Storage Temperature ℃ -40~+85 For device with connector, IL is 0.3dB higher, RL is 5dB lower, ER is 2dB lower; The default connector key is aligned to slow axis;
Package Dimensions
Ordering Information PMFWDM-1111-2345-666
1111 -Operating 5548=T1550nm/R1480nm, 5598=T1550nm/R980nm, 0608=T1064nm/R980nm,...... 2 -Port Number 1=1x1, 2=1x2 3 -Fiber type 1=PM Panda fiber 4 -Pigtail type: 0=250 bare fiber, 1=900um loose tube, 2=2.0mm loose tube, 3=3.0 loose tube 5 -Fiber length: 0=0.8m,1=1m
666 -Connector type: 0=FC/UPC,1=FC/APC,2=SC/UPC,3=SC/APC,4=LC/UPC,5=LC/APC
22/39 Shenzhen Ruik-tech Communication Co.,LTD. Web: Http://www.ruik-tech.com Tel:86+0755-23056383 Fax:86+0755-29071321 e-mail:[email protected]
Ruik-tech Communication (H.K.) CO.,LTD
PM Filter WDM(C/L)
Features Applications Low Insertion Loss Fiber Laser High Return Loss Fiber Amplifier High Reliability & Stability Testing Equipment Specifications Parameters Unit Values Type nm C+L Band Transmission Wavelength nm 1510~1563 Reflection Wavelength nm 1570~1610 Max. Insertion Loss of Transmission Channel dB 0.8 Max. Insertion Loss of Reflection Channel dB 0.6 Min. Transmission Isolation @Reflection Wavelength dB 25 Min. Reflection Isolation @Transmission Wavelength dB 12 Max. Channel Flatness dB 0.3 Min. Extinction Ratio dB 18 Min. Return Loss N 50 Insertion loss thermal Stability dB/ 0.005 Max.Power Handling (CW) mW 300 Fiber Type - SMF-28e,Hi1060 Operating Temperature ℃ 0 ~ +65 Storage Temperature ℃ -40~+85 For device with connector, IL is 0.3dB higher, RL is 5dB lower, ER is 2dB lower; The default connector key is aligned to slow axis;
Package Dimensions
Ordering Information PMFWDM-1111-234-555
1111 -Operating 1671=T1510~1563nm/R1570~1610nm, 5598=T1550nm/R980nm ...... 2 -Port Number 1=1x1, 2=1x2 3 -Pigtail type: 0=250 bare fiber, 1=900um loose tube, 2=2.0mm loose tube, 3=3.0 loose tube 4 -Fiber length: 0=0.8m,1=1m
555 -Connector type: 0=FC/UPC,1=FC/APC,2=SC/UPC,3=SC/APC,4=LC/UPC,5=LC/APC
23/39 Shenzhen Ruik-tech Communication Co.,LTD. Web: Http://www.ruik-tech.com Tel:86+0755-23056383 Fax:86+0755-29071321 e-mail:[email protected]
Ruik-tech Communication (H.K.) CO.,LTD
Polarization Maintaining Isolation WDM
Features Applications Low Insertion Loss Fiber Laser High Return Loss Fiber Amplifier High Isolation Testing Equipment High Extinction Ratio High Reliability & Stability Specifications Parameter Unit Value Stage - Single Dual
Signal Wavelength Range nm 1535~1565 Max. Insertion Loss dB 0.9 1.0 Typ. Insertion Loss dB 0.7 0.8 Typ. Peak Signal Isolation, at 23℃ dB 40 52 Min. Signal Isolation, at 23℃ dB 28 45 Min. Extinction Ratio( only for F type) dB 23
Signal Channel
Min. Extinction Ratio( only for B type) dB 20 Wavelength Range nm 960~990 or 1460~1490 Max. Insertion Loss dB 0.5 Reflection Channel Typ. Insertion Loss dB 0.3
Min. Return Loss dB 50 Max. IL Thermal Stability dB/℃ 0.005 Max. Optical Power(CW) mW 300 Max. Tensile Load N 5 Fiber Type - PM Panda Fiber, Hi1060 or SMF-28e Operating Temperature ℃ -5~+70 Storage Temperature ℃ -40~+85 For device with connector, IL is 0.3dB higher, RL is 5dB lower, ER is 2dB lower; The default connector key is aligned to slow axis;
Package Dimensions
Ordering Information PMIWDM-1111-2345-666
1111 -Pump wavelength: 1550=1550nm,1310=1310nm,......,0850=850nm 2 -Stage: S=Single-core stage, D=Dual-core stage 3 -Axis alignment: F=Slow axis working, Fast axis blocked, B=Both of axis working 4 -Pigtail type: 0=250 bare fiber, 1=900um loose tube, 2=2.0mm loose tube, 3=3.0 loose tube 5 -Fiber length: 0=0.8m,1=1m
666 -Connector type: 0=FC/UPC,1=FC/APC,2=SC/UPC,3=SC/APC,4=LC/UPC,5=LC/APC
24/39 Shenzhen Ruik-tech Communication Co.,LTD. Web: Http://www.ruik-tech.com Tel:86+0755-23056383 Fax:86+0755-29071321 e-mail:[email protected]
Ruik-tech Communication (H.K.) CO.,LTD
Polarization Maintaining Fiber Patchcord
Features Applications
Low Insertion Loss Optical Fiber Amplifiers
High Return Loss Test Instrumentations
High Extinction Ratio Fiber Sensor
High Reliability Research
High Stability Fiber Laser
Specifications
Parameter Unit Value
Connector Type - FC/UPC, SC/UPC,LC/UPC,MU/UPC
Center Wavelength nm 1310, 1550 980, 1060 850 780
Max.Insertion Loss nm 0.3 0.5 0.8 0.8
Min.Extinction Ratio at 23℃ dB 23 23 22 22
UPC Type dB 50 Min.Return loss
APC Type dB 60
Fiber Type - PM Panda Fiber
Key Orientation - Slow Axis
Axis Alignment deg ±3
Operating Temperature ℃ -20~+70
Storage Temperature ℃ -40~+85
The default connector key is aligned to slow axis;
Package Dimensions
Ordering Information
PMJP-1111-23456
1111 -Operating wavelength: 1550=1550nm,1310=1310nm,......,0850=850nm
2 -Fiber type 0=PM Panda fiber, 1=smf-28e, 2=hi1060,
3 -Connector type for 0=FC/UPC,1=FC/APC,2=SC/UPC,3=SC/APC,4=LC/UPC,5=LC/APC
4 -Connector type for 0=FC/UPC,1=FC/APC,2=SC/UPC,3=SC/APC,4=LC/UPC,5=LC/APC
5 -Pigtail type: 0=250 bare fiber, 1=900um loose tube, 2=2.0mm loose tube, 3=3.0 loose tube
6 -Fiber length: 0=0.8m,1=1m
25/39 Shenzhen Ruik-tech Communication Co.,LTD. Web: Http://www.ruik-tech.com Tel:86+0755-23056383 Fax:86+0755-29071321 e-mail:[email protected]
Ruik-tech Communication (H.K.) CO.,LTD
PM Manual Variable Optical Attenuator
Features Applications High Precision Optical Communication Systems Test
Wide Attenuation Range Optics Laboratory
Low Insertion Loss
Specifications Parameter Unit Value
Center Wavelength nm 1310 1550 1064
Operating Wavelength Range nm ±40 ±40 ±20
Attenuation Range dB 0.6~60 0.6~60 0.6~60
Max.Insertion Loss dB 0.6 0.6 0.6
Min.Return Loss dB 50
Fiber Type - PM Panda fiber
Adjustment Precision dB 0.02
Max.Polarization Dependent Loss dB 0.15
Max.Power Handling mW 500
Operating Temperature ℃ 0 ~ +70
Storage Temperature ℃ -40~+85
Packag Dimensions mm 26x18x8 For device with connector, IL is 0.3dB higher, RL is 5dB lower, ER is 2dB lower; The default connector key is aligned to slow axis;
Package Dimensions
Ordering Information PMMVOA-1111-234-55
1111 -Center wavelength: 1550=1550nm, 1310=1310nm,......, 850=850nm
2 -Fiber type 1=PM Panda fiber
3 -Pigtail type: 0=250 bare fiber, 1=900um loose tube, 2=2.0mm loose tube, 3=3.0 loose tube
4 -Fiber length: 0=0.8m,1=1m
55 -Connector type: 0=FC/UPC,1=FC/APC,2=SC/UPC,3=SC/APC,4=LC/UPC,5=LC/APC
26/39 Shenzhen Ruik-tech Communication Co.,LTD. Web: Http://www.ruik-tech.com Tel:86+0755-23056383 Fax:86+0755-29071321 e-mail:[email protected]
Ruik-tech Communication (H.K.) CO.,LTD
2W High Power Isolator(1310nm,1480nm,1550nm)
Features Applications Low Insertion Loss Testing Instrumentations Low Polarization Dependent Loss Transmitters High Return Loss Fiber Laser High Isolation WDM System High Stability & Reliability Specifications Parameters Unit Value Stage - Dual Single Center Wavelength nm 1310, 1480 or 1550 Operating Wavelength Range nm ±20 Typ. Insertion Loss at 23 ℃ dB 0.40 0.35 Max. Insertion Loss at 23℃ dB 0.55 0.50 Typ. Isolation at 23℃ dB 58 42 Min. Isolation at 23℃ dB 48 28 Max. Polarization Dependent Loss at 23℃ dB 0.15 /
Fast axis blocked dB / 23 Extinction Ratio at 23℃
Both of axis working dB / 20 Return Loss(Input/output) dB 50/50 Max. Optical Power(CW) W 1,2 Max. Optical Power(Pulse Peak) kW 10 Max. Tensile Load N 5 Fiber Type - SMF-28e Operating Temperature ℃ -5~+70 Storage Temperature ℃ -40~+85
Package Dimensions
Ordering Information
HPIIS/HPMIS-1111-234567-88 1111 -Center Wavelength: 1550=1550nm, 1480=1480nm, 1310=1310nm......
2 -Stage: S=Single-core stage, D=Dual-core stage 3 -Fiber type: 0=smf-28e, 1=PM Panda fiber 4 -Axis alignment F=Slow axis working Fast axis blocked, B=Both of axis working, N=No axis 5 -Pigtail type: 0=250 bare fiber, 1=900um loose tube, 2=2.0mm loose tube, 3=3.0 loose tube 6 -Fiber length: 0=0.8m,1=1m 7 -Package Dimension: 0=φ5.5x35mm, 1=L60xW12xD10mm
88 -Handling Power 01=1W, 02=2W,......,05=5W,......, 20=20W
27/39 Shenzhen Ruik-tech Communication Co.,LTD. Web: Http://www.ruik-tech.com Tel:86+0755-23056383 Fax:86+0755-29071321 e-mail:[email protected]
Ruik-tech Communication (H.K.) CO.,LTD
5W/20W 1550nm High Power Isolator
Features Applications Low Insertion Loss Testing Instrumentations Low Polarization Dependent Loss Transmitters High Return Loss Fiber Laser High Isolation WDM System Specifications Parameters Unit Value Stage - Dual Single Center Wavelength nm 1310, 1480or1550 Operating Wavelength Range nm ±20 Typ. Insertion Loss at 23 ℃ dB 0.40 0.35 Max. Insertion Loss at 23℃ dB 0.55 0.50 Typ. Isolation at 23℃ dB 58 42 Min. Isolation at 23℃ dB 48 28 Max. Polarization Dependent Loss at 23℃ dB 0.15 / Extinction Ratio at 23℃ Fast axis blocked dB / 23 Both of axis working dB / 20 Return Loss(Input/output) dB 50/50 Max. Optical Power(CW) W 5,10 or specify Max. Tensile Load N 5 Fiber Type - SMF-28e or PM Panda fiber Operating Temperature ℃ -5~+70 Storage Temperature ℃ -40~+85 Package Dimension mm 60x12x10 With Connector, the handling power will be only 1w Package Dimensions
Ordering Information HPIIS/HPMIS-1111-234567-88
1111 -Center Wavelength: 1550=1550nm, 1480=1480nm, 1310=1310nm...... 2 -Stage: S=Single-core stage, D=Dual-core stage 3 -Fiber type: 0=smf-28e, 1=PM Panda fiber 4 -Axis alignment F=Slow axis working Fast axis blocked, B=Both of axis working 5 -Pigtail type: 0=250 bare fiber, 1=900um loose tube, 2=2.0mm loose tube, 3=3.0 loose tube 6 -Fiber length: 0=0.8m,1=1m 7 -Package Dimension: 0=φ5.5x35mm, 1=L60xW20xD10mm
88 -Handling Power 01=1W, 02=2W,......,05=5W,......, 20=20W
28/39 Shenzhen Ruik-tech Communication Co.,LTD. Web: Http://www.ruik-tech.com Tel:86+0755-23056383 Fax:86+0755-29071321 e-mail:[email protected]
Ruik-tech Communication (H.K.) CO.,LTD
5W/20W 850nm High Power Isolator
Features Applications Low Insertion Loss Polarization Maintaining Fiber Amplifier High Return Loss Testing Instrumentations High Isolation Fiber Sensor High Stability & Reliability Fiber Laser Lab Research Specifications Parameters Unit Value Type - HPIIS HPMIS Center Wavelength nm 850 Operating Wavelength Range nm ±10 Typ. Peak Isolation at 23℃ dB 32~40 Isolation at 23℃ dB 25 Typ. Insertion Loss at 23℃ dB 0.6 Max. Insertion Loss at 23℃ dB 1.0 Max.PDL at 23 ( only for HPIIS)℃ dB 0.15 /
only for B type dB / 22 Extinction Ratio
only for F type dB / 22 Return Loss(Input/Output) dB 50/50 Max. Optical Power(CW) W 1, 2, 5 or specify Max. Tensile Load N 5 Fiber Type - Hi 780 PM Panda Fiber Package Dimension mm 63x33x34
Package Dimensions
Ordering Information HPMIS/HPIIS-1111-23456-77
1111 -Center Wavelength: 850=850nm 2 -Axis alignment F=Slow axis working Fast axis blocked, B=Both of axis working, N=No axis 3 -Fiber type 0=PM Panda fiber, 1=SMF-28e, 2=Hi1060, 3=Hi780 4 -Pigtail type: 0=250 bare fiber, 1=900um loose tube, 2=2.0mm loose tube, 3=3.0 loose tube 5 -Fiber length: 0=0.8m,1=1m 6 -Package Dimension: 0=63x34x33mm, S=Specified
77 -Handling Power 01=1W, 02=2W,......,05=5W,......, 20=20W
29/39 Shenzhen Ruik-tech Communication Co.,LTD. Web: Http://www.ruik-tech.com Tel:86+0755-23056383 Fax:86+0755-29071321 e-mail:[email protected]
Ruik-tech Communication (H.K.) CO.,LTD
5W/20W 980nm High Power Isolator
Features Applications Low Insertion Loss Polarization Maintaining Fiber Amplifier High Return Loss Testing Instrumentations High Isolation Fiber Sensor High Stability & Reliability Fiber Laser Lab Research Specifications Parameters Unit Value Type - HPIIS HPMIS Center Wavelength nm 980 Operating Wavelength Range nm ±10 Typ. Peak Isolation at 23℃ dB 32~40 Isolation at 23℃ dB 25 Typ. Insertion Loss at 23℃ dB 0.6 Max. Insertion Loss at 23℃ dB 1.0 Max.PDL at 23 ( only℃ for HPIIS) dB 0.15 /
only for B type dB / 20 Extinction Ratio
only for F type dB / 22 Return Loss(Input/Output) dB 50/50 Max. Optical Power(CW) W 1, 2, 5 or specify Max. Tensile Load N 5 Fiber Type - Hi 1060 PM Panda Fiber Package Dimension mm
Package Dimensions
Ordering Information HPMIS/HPIIS-1111-23456-77
1111 -Center Wavelength: 980=980nm 2 -Axis alignment F=Slow axis working Fast axis blocked, B=Both of axis working, N=No axis 3 -Fiber type 0=PM Panda fiber, 1=SMF-28e, 2=Hi1060, 3=Hi780 4 -Pigtail type: 0=250 bare fiber, 1=900um loose tube, 2=2.0mm loose tube, 3=3.0 loose tube 5 -Fiber length: 0=0.8m,1=1m 6 -Package Dimension: 0=72*34*33mm, S=Specified
77 -Handling Power 01=1W, 02=2W,......,05=5W,......, 20=20W
30/39 Shenzhen Ruik-tech Communication Co.,LTD. Web: Http://www.ruik-tech.com Tel:86+0755-23056383 Fax:86+0755-29071321 e-mail:[email protected]
Ruik-tech Communication (H.K.) CO.,LTD
5W/20W 1030 nm High Power Isolator
Features Applications Low Insertion Loss Polarization Maintaining Fiber Amplifier High Return Loss Testing Instrumentations High Isolation Fiber Sensor High stability & Reliability Fiber Laser Lab Research Specifications Parameters Unit Value Type - HPIIS HPMIS Center Wavelength nm 1030 Operating Wavelength Range nm ±10 Typ. Peak Isolation at 23℃ dB 30 Isolation at 23℃ dB 25 Typ. Insertion Loss at 23℃ dB 1.3 Max. Insertion Loss at 23℃ dB 1.5 Max. Polarization Dependent Loss at 23℃ dB 0.15 / Extinction Ratio at 23℃ Fast axis blocked dB / 22 Both of axis working dB / 20 Min. Return Loss(Input /Output) dB 45 Max. Optical Power CW W 1,2, 3, 5,10,20 or specify Pulse Peak kW 10 Max. Tensile Load N 5 Fiber Type - HI 1060 fiber or specify PM980 fiber or specify Package Dimension mm
Package Dimensions
Ordering Information HPIIS/HPMIS-1030-234567-88
1064 -Center Wavelength: 1030=1030nm 2 -Fiber type 0=PM Panda fiber, 1=SMF-28E, 2=Hi1060 3 -Axis alignment F=Slow axis working Fast axis blocked, B=Both of axis working 4 -Pigtail type: 0=250 bare fiber, 1=900um loose tube, 2=2.0mm loose tube, 3=3.0 loose tube 5 -Fiber length: 0=0.8m,1=1m 6 -Package Dimension: 0=81*34*33mm, S=specified
77 -Handling Power 01=1W, 02=2W,......,05=5W,......, 20=20W
31/39 Shenzhen Ruik-tech Communication Co.,LTD. Web: Http://www.ruik-tech.com Tel:86+0755-23056383 Fax:86+0755-29071321 e-mail:[email protected]
Ruik-tech Communication (H.K.) CO.,LTD
5W/20W 1064 nm High Power Isolator
Features Applications Low Insertion Loss Polarization Maintaining Fiber Amplifier High Return Loss Testing Instrumentations High Isolation Fiber Sensor High stability & Reliability Fiber Laser Lab Research Specifications Parameters Unit Value Type - HPIIS HPMIS Center Wavelength nm 1064 Operating Wavelength Range nm ±20 Typ. Peak Isolation at 23℃ dB 32~40 Isolation at 23℃ dB 25 Typ. Insertion Loss at 23℃ dB 0.6 Max. Insertion Loss at 23℃ dB 1.0 Max. Polarization Dependent Loss at 23℃ dB 0.15 / Extinction Ratio at 23℃ Fast axis blocked dB / 23 Both of axis working dB / 20 Min. Return Loss(Input /Output) dB 50 Max. Optical Power CW W 1,2, 3, 5,10,20 or specify Pulse Peak kW 10 Max. Tensile Load N 5 Fiber Type - HI 1060 fiber or specify PM980 fiber or specify Package Dimension mm
Package Dimensions
Ordering Information HPIIS/HPMIS-1064-234567-88
1064 -Center Wavelength: 1064=1064nm 2 -Fiber type 0=PM Panda fiber, 1=SMF-28E, 2=Hi1060 3 -Axis alignment F=Slow axis working Fast axis blocked, B=Both of axis working, N=No axis 4 -Pigtail type: 0=250 bare fiber, 1=900um loose tube, 2=2.0mm loose tube, 3=3.0 loose tube 5 -Fiber length: 0=0.8m,1=1m 6 -Package Dimension: 0=81*34*33mm, S=specified
77 -Handling Power 01=1W, 02=2W,......,05=5W,......, 20=20W
32/39 Shenzhen Ruik-tech Communication Co.,LTD. Web: Http://www.ruik-tech.com Tel:86+0755-23056383 Fax:86+0755-29071321 e-mail:[email protected]
Ruik-tech Communication (H.K.) CO.,LTD
5W/20W 980nm High Power Circulator
Features Applications Low Insertion Loss Polarization Maintaining Fiber Amplifier High Return Loss Testing Instrumentations High Isolation Fiber Sensor High Stability & Reliability Medical Equipment Specifications Parameters Unit Value Type - HPCIR HPMCIR Center Wavelength nm 980 Operating Wavelength Range nm ±5 Typ. Peak Isolation dB 25 Isolation at 23℃ dB 22 Typ. Insertion Loss at 23℃ dB 1.3 Max. Insertion Loss at 23℃ dB 1.5 Max. Polarization Dependent Loss at 23℃ dB 0.15 / Extinction Ratio at 23℃ Fast axis blocked dB / 23 Both of axis working dB / 20 Return Loss(Input/ Output) dB 45 Min. Cross Talk dB 45
CW W 1,2,3,5,10 Max. Optical Power
Pulse Peak kW 10 Max. Tensile Load N 5 Fiber Type - Hi 1060 PM Pand Fiber Package Dimension mm
Package Dimensions
Ordering Information HPMCIR/HPICIR-980-23456-77
1064 -Center wavelength: 980=980nm 2 -Axis alignment B=Both of axis working, F=Slow axis working, Fast axis blocked, N=No axis 3 -Fiber type 0=PM Panda fiber, 2=Hi1060 4 -Pigtail type: 0=250 bare fiber, 1=900um loose tube, 2=2.0mm loose tube, 3=3.0 loose tube 5 -Fiber length: 0=0.8m,1=1m 6 -Package Dimension: 0=82x38x38mm, S=Specified
77 -Handling Power 01=1W, 02=2W,......,05=5W,......, 20=20W
Ruik-tech Communication (H.K.) CO.,LTD
33/39 Shenzhen Ruik-tech Communication Co.,LTD. Web: Http://www.ruik-tech.com Tel:86+0755-23056383 Fax:86+0755-29071321 e-mail:[email protected]
Ruik-tech Communication (H.K.) CO.,LTD
5W/20W 1064nm High Power Circulator
Features Applications Low Insertion Loss Polarization Maintaining Fiber Amplifier High Return Loss Testing Instrumentations High Isolation Fiber Sensor High Stability & Reliability Medical Equipment Specifications Parameters Unit Value Type - HPCIR HPMCIR Center Wavelength nm 1064 Operating Wavelength Range nm ±5 Typ. Peak Isolation dB 25 Isolation at 23℃ dB 22 Typ. Insertion Loss at 23℃ dB 1.3 Max. Insertion Loss at 23℃ dB 1.5 Max. Polarization Dependent Loss at 23℃ dB 0.15 / Extinction Ratio at 23℃ Fast axis blocked dB / 23 Both of axis working dB / 20 Return Loss(Input/ Output) dB 45 Min. Cross Talk dB 45
CW W 1,2,3,5,10 Max. Optical Power
Pulse Peak kW 10 Max. Tensile Load N 5 Fiber Type - Hi 1060 PM Panda Fiber Package Dimension mm
Package Dimensions
Ordering Information HPMCIR/HPICIR-1064-23456-77
1064 -Center wavelength: 1064=1064nm 2 -Axis alignment F=Slow axis working Fast axis blocked, B=Both of axis working, N=No axis 3 -Fiber type 0=PM Panda fiber, 2=Hi1060, ...... 4 -Pigtail type: 0=250 bare fiber, 1=900um loose tube, 2=2.0mm loose tube, 3=3.0 loose tube 5 -Fiber length: 0=0.8m,1=1m 6 -Package Dimension: 0=81*34*33mm, S=Specified
77 -Handling Power 01=1W, 02=2W,......,05=5W,......, 20=20W
34/39 Shenzhen Ruik-tech Communication Co.,LTD. Web: Http://www.ruik-tech.com Tel:86+0755-23056383 Fax:86+0755-29071321 e-mail:[email protected]
Ruik-tech Communication (H.K.) CO.,LTD
2W High power In-line Polarizer
Features Applications Low Insertion Loss Communication Systems High Return Loss Test Instrumentations High Extinction Ratio Fiber Sensor High Reliability Research High Stability Specifications Parameters Unit Value Center Wavelength nm 1310, 1550 1064 980 850 Operating Wavelength Range nm ±50 ±30 ±10 ±10 Typ. Insertion Loss at 23 ℃ dB 0.3 0.4 0.7 0.8 Max. Insertion Loss at 23℃ dB 0.5 0.6 0.9 1 Min. Return Loss dB 50 50 50 50 Typ. Extinction Ratio at 23℃ dB 30 30 28 28 Min. Extinction Ratio at 23℃ dB 28 28 25 25 Max. Optical Power(CW) W 2 Max. Optical Power(Pulse Peak) kW 10 Max. Tensile Load N 5
PM1550 PM980 PM980 PM850 Fiber Type -
SMF-28E Hi1060 Hi1060 SM800 Operating Temperature ℃ -5~+70 Storage Temperature ℃ -40~+85 For device with connector, IL is 0.3dB higher, RL is 5dB lower, ER is 2dB lower; The default connector key is aligned to slow axis;
Package Dimensions
Ordering Information ILP-1111-2345-66
1111 -Center Wavelength: 1550=1550nm,1310=1310nm,......,0850=850nm 2 -Fiber type for input: 0=Panda fiber, 1=smf-28e, 2=hi1060, 3 -Fiber type for output: 0=Panda fiber, 1=smf-28e, 2=hi1060, 4 -Pigtail type: 0=250 bare fiber, 1=900um loose tube, 2=2.0mm loose tube, 3=3.0 loose tube 5 -Fiber length: 0=0.8m,1=1m
66 -Handling power: 01=1W, 02=2W
Ruik-tech Communication (H.K.) CO.,LTD
35/39 Shenzhen Ruik-tech Communication Co.,LTD. Web: Http://www.ruik-tech.com Tel:86+0755-23056383 Fax:86+0755-29071321 e-mail:[email protected]
Ruik-tech Communication (H.K.) CO.,LTD
5W/10W High power In-line Polarizer
Features Applications Low Insertion Loss Communication Systems High Return Loss Test Instrumentations High Extinction Ratio Fiber Sensor High Reliability Research High Stability Specifications Parameters Unit Value Center Wavelength nm 1310, 1550 1064 980 850 Operating Wavelength Range nm ±50 ±30 ±10 ±10 Typ. Insertion Loss at 23 ℃ dB 0.3 0.4 0.7 0.8 Max. Insertion Loss at 23℃ dB 0.5 0.6 0.9 1 Min. Return Loss dB 50 50 50 50 Typ. Extinction Ratio at 23℃ dB 30 30 28 28 Min. Extinction Ratio at 23℃ dB 28 28 25 25 Max. Optical Power(CW) W 2,5,10 Max. Optical Power(Pulse Peak) kW 10 Max. Tensile Load N 5
PM1550 PM980 PM980 PM850 Fiber Type -
SMF-28E Hi1060 Hi1060 SM800 Operating Temperature ℃ -5~+70 Storage Temperature ℃ -40~+85 Package Dimension mm 60x12x10
Package Dimensions
Ordering Information ILP-1111-2345-66
1111 -Center Wavelength: 1550=1550nm,1310=1310nm,......,0850=850nm 2 -Fiber type for input: 0=Panda fiber, 1=smf-28e, 2=hi1060, 3 -Fiber type for output: 0=Panda fiber, 1=smf-28e, 2=hi1060, 4 -Pigtail type: 0=250 bare fiber, 1=900um loose tube, 2=2.0mm loose tube, 3=3.0 loose tube 5 -Fiber length: 0=0.8m,1=1m
66 -Handling power: 01=1W, 02=2W, 05=5W, 10=10W
Ruik-tech Communication (H.K.) CO.,LTD
36/39 Shenzhen Ruik-tech Communication Co.,LTD. Web: Http://www.ruik-tech.com Tel:86+0755-23056383 Fax:86+0755-29071321 e-mail:[email protected]
Ruik-tech Communication (H.K.) CO.,LTD
5W/10W High power PBC/S
Features Applications Low Insertion Loss Optical Fiber Transducer High Return Loss Fiber Sensor High Extinction Ratio Optical Fiber Gyro High Reliability Coherent Telecommunication Systems High Stability Specifications Parameters Unit Values Grade - P A P A Center Wavelength nm 1310,1550 1064,980 Operating Wavelength Range nm ±40 ±20 Typ. Insertion Loss at 23 ℃ dB 0.4 0.5 0.6 0.7 Max. Insertion Loss at 23℃ dB 0.6 0.7 0.8 0.9 Min. Extinction Ratio at 23℃ dB 22 20 22 20 Directivity dB 50 Min. Return Loss dB 50 Max. Optical Power(CW) mW 1,2,5,10 Max. Optical Power(Pulse Peak) kW 10 Max. Tensile Load N 5
Port1 & 2 PM Panda Fiber Fiber Type
Port3 -
SMF-28e, HI1060 or PM Panda fiber Operating temperature ℃ -5~+70 Storage temperature ℃ -40~+85 Package Dimension mm 60x12x10
Package Dimensions
Ordering Information HPPBC/S-11-23456-77
1111 -Center Wavelength: 1550=1550nm,1310=1310nm,......,850=850nm 2 -Grade: P=Perfect grade, A=A grade 3 -Fiber type for Port 3: 1=Panda fiber aligned to Port1,2=smf-28e,3=hi1060,4=Panda fiber 45°aligned to Port1 4 -Fiber type for Port 1=Panda fiber, 2=smf-28e,3=hi1060 5 -Pigtail type: 0=250 bare fiber, 1=900um loose tube, 2=2.0mm loose tube, 3=3.0 loose tube 6 -Fiber length: 0=0.8m,1=1m
77 -Handling power: 01=1W, 02=2W, 05=5W, 10=10W
37/39 Shenzhen Ruik-tech Communication Co.,LTD. Web: Http://www.ruik-tech.com Tel:86+0755-23056383 Fax:86+0755-29071321 e-mail:[email protected]
Ruik-tech Communication (H.K.) CO.,LTD
Polarization Maintaining Tap Isolator
Features Applications Low Insertion Loss Compact Fiber Amplifiers High Return Loss Compact Fiber Optical System High Extinction Ratio Fiber Laser High Isolation Fiber Sensor High Stability & Reliability Specifications Parameter Unit Value Stage - Single Dual Operating Wavelength Range nm 1530~1570 Max. Insertion Loss dB 0.8(for 1%), 1(for 5%) 1.0(for 1%),1.2(for 5%) Signal Tap Ratio % 1±0.5, 5±1 1±0.5, 5±1 Typ. Peak Isolation dB 40 52 Min. Isolation at 23℃ dB 28 45 Min. Extinction Ratio(only for F type) dB 23 23 Min. Extinction Ratio(only for B type) dB 20 20 Min. Return Loss(all ports) dB 50 50 Max. Optical Power(CW) mW 300 Max. Tensile Load N 5 Fiber Type - PM Panda Fiber, SMF-28e Operating Temperature ℃ 0~+70 Storage Temperature ℃ -40~+85 For device with connector, IL is 0.3dB higher, RL is 5dB lower, ER is 2dB lower; The default connector key is aligned to slow axis;
Package Dimensions
Ordering Information PMTIS-1111-234456-777
1550 -Center wavelength: 1550=1550nm,...... 2 -Stage: S=Single-core stage, D=Dual-core stage 3 -Axis alignment F=Slow axis working Fast axis blocked, B=Both of axis working
44 -Tap ratio: 01=1%, 02=2%, ......, 50=50% 5 -Pigtail type: 0=250 bare fiber, 1=900um loose tube, 2=2.0mm loose tube, 3=3.0 loose tube 6 -Fiber length: 0=0.8m,1=1m
777 -Connector type: 0=FC/UPC,1=FC/APC,2=SC/UPC,3=SC/APC,4=LC/UPC,5=LC/APC
38/39 Shenzhen Ruik-tech Communication Co.,LTD. Web: Http://www.ruik-tech.com Tel:86+0755-23056383 Fax:86+0755-29071321 e-mail:[email protected]
Ruik-tech Communication (H.K.) CO.,LTD
1x2 Isolatior Porization Beam.Combiner/Splitter
Features Applications Low Insertion Loss EDFA & Raman Amplifier High Return Loss Fiber Sensor High Extinction Ratio Coherent Telecommunication Systems High Reliability Polarization Mode Dispersion Compensator High Stability Specifications Parameters Unit Values Stage - Dual Single Center Wavelength nm 1310,1550 1310,1550 1064 Operating Wavelength Range nm ±20 ±20 ±5 Typ.Insertion Loss at 23 ℃ dB 0.55 0.45 1.8 Max.Insertion Loss at 23℃ dB 0.80 0.70 2.1 Typ.Isolation dB 51 35 35 Min.Isolation dB 42 20 25 Min.Extinction Ratio dB 25 20 20 Directivity dB 50 Min.Return Loss dB 50 Max.Optical Power(CW) mW 300 Max.Tensile Load N 5
Port1 & 2 - PM Panda Fiber Fiber Type Port3 - PM Panda Fiber or SMF-28e or Hi1060
Operating Temperature ℃ -5~+70 Storage Temperature ℃ -40~+85 For device with connector, IL is 0.3dB higher, RL is 5dB lower, ER is 2dB lower; The default connector key is aligned to slow axis;
Package Dimensions
Ordering Information IPBC/S-1111-23456-777
1111 -Center Wavelength: 1550=1550nm,1310=1310nm,......,0850=850nm 2 -Grade: S=Single-core type, D=Dual-core type 3 -Fiber type for Port 3: 1=Panda fiber aligned to Port1,2=smf-28e,3=hi1060,4=Panda fiber 45°aligned to Port1 4 -Fiber type for Port 1,2: 1=Panda fiber, 2=smf-28e, 3=hi1060 5 -Pigtail type 0=250 bare fiber, 1=900um loose tube, 2=2.0mm loose tube, 3=3.0 loose tube 6 -Fiber length: 0=0.8m,1=1m
777 -Connector type: 0=FC/UPC,1=FC/APC,2=SC/UPC,3=SC/APC,4=LC/UPC,5=LC/APC
Ruik-tech Communication (H.K.) CO.,LTD
39/39 Shenzhen Ruik-tech Communication Co.,LTD. Web: Http://www.ruik-tech.com Tel:86+0755-23056383 Fax:86+0755-29071321 e-mail:[email protected]
Ruik-tech Communication (H.K.) CO.,LTD
Polarization Maintaining Tap Isolator
Features Applications Low Insertion Loss Compact Fiber Amplifiers High Return Loss Compact Fiber Optical System High Extinction Ratio Fiber Laser High Isolation Fiber Sensor High Stability & Reliability Specifications Parameter Unit Value Stage - Single Dual Operating Wavelength Range nm 1530~1570 Max. Insertion Loss dB 0.8(for 1%), 1(for 5%) 1.0(for 1%),1.2(for 5%) Signal Tap Ratio % 1±0.5, 5±1 1±0.5, 5±1 Typ. Peak Isolation dB 40 52 Min. Isolation at 23℃ dB 28 45 Min. Extinction Ratio(only for F type) dB 23 23 Min. Extinction Ratio(only for B type) dB 20 20 Min. Return Loss(all ports) dB 50 50 Max. Optical Power(CW) mW 300 Max. Tensile Load N 5 Fiber Type - PM Panda Fiber, SMF-28e Operating Temperature ℃ 0~+70 Storage Temperature ℃ -40~+85 For device with connector, IL is 0.3dB higher, RL is 5dB lower, ER is 2dB lower; The default connector key is aligned to slow axis;
Package Dimensions
Ordering Information PMTIS-1111-234456-777
1550 -Center wavelength: 1550=1550nm,...... 2 -Stage: S=Single-core stage, D=Dual-core stage 3 -Axis alignment F=Slow axis working Fast axis blocked, B=Both of axis working
44 -Tap ratio: 01=1%, 02=2%, ......, 50=50% 5 -Pigtail type: 0=250 bare fiber, 1=900um loose tube, 2=2.0mm loose tube, 3=3.0 loose tube 6 -Fiber length: 0=0.8m,1=1m
777 -Connector type: 0=FC/UPC,1=FC/APC,2=SC/UPC,3=SC/APC,4=LC/UPC,5=LC/APC