28
PRODUCT LINE OVERVIEW

PRODUCT LINE OVERVIEW - Vectus€¦ · © TSI Incorporated 10/20/2016 TSI CONFIDENTIAL + 0.1 CFM, 3-6 Channels + 0.3 µm -10 µm + On board memory TSI Product Overview 930X Handheld

  • Upload
    others

  • View
    7

  • Download
    0

Embed Size (px)

Citation preview

Page 1: PRODUCT LINE OVERVIEW - Vectus€¦ · © TSI Incorporated 10/20/2016 TSI CONFIDENTIAL + 0.1 CFM, 3-6 Channels + 0.3 µm -10 µm + On board memory TSI Product Overview 930X Handheld

PRODUCT LINE

OVERVIEW

Page 2: PRODUCT LINE OVERVIEW - Vectus€¦ · © TSI Incorporated 10/20/2016 TSI CONFIDENTIAL + 0.1 CFM, 3-6 Channels + 0.3 µm -10 µm + On board memory TSI Product Overview 930X Handheld

10/20/2016 © TSI Incorporated

TSI CONFIDENTIAL

Take-aways

2

TSI has handheld, portable and remote instruments

Model numbers give sample flow rate and minimum particle size

You can win with TSI products

Page 3: PRODUCT LINE OVERVIEW - Vectus€¦ · © TSI Incorporated 10/20/2016 TSI CONFIDENTIAL + 0.1 CFM, 3-6 Channels + 0.3 µm -10 µm + On board memory TSI Product Overview 930X Handheld

10/20/2016 © TSI Incorporated

TSI CONFIDENTIAL

+ Exposure assessment

+ Locate contaminant sources

+ Monitor particle size distributions

+ Check manufacturing processes

+ IAQ investigations

TSI Product Overview

Spot-Checks

3

Page 4: PRODUCT LINE OVERVIEW - Vectus€¦ · © TSI Incorporated 10/20/2016 TSI CONFIDENTIAL + 0.1 CFM, 3-6 Channels + 0.3 µm -10 µm + On board memory TSI Product Overview 930X Handheld

10/20/2016 © TSI Incorporated

TSI CONFIDENTIAL

+ 0.1 CFM, 3-6 Channels

+ 0.3 µm -10 µm

+ On board memory

TSI Product Overview

930X Handheld

4

9303 – 3 channel 9306 – 6 channel

Page 5: PRODUCT LINE OVERVIEW - Vectus€¦ · © TSI Incorporated 10/20/2016 TSI CONFIDENTIAL + 0.1 CFM, 3-6 Channels + 0.3 µm -10 µm + On board memory TSI Product Overview 930X Handheld

10/20/2016 © TSI Incorporated

TSI CONFIDENTIAL

Handheld Instrument

Components

5

• Plastic case

Page 6: PRODUCT LINE OVERVIEW - Vectus€¦ · © TSI Incorporated 10/20/2016 TSI CONFIDENTIAL + 0.1 CFM, 3-6 Channels + 0.3 µm -10 µm + On board memory TSI Product Overview 930X Handheld

10/20/2016 © TSI Incorporated

TSI CONFIDENTIAL

+ Test, monitor and certify cleanroom environments (clean zones) for pharmaceuticals, medical devices, semi-conductor, aerospace.

+ Test filter performance and certify efficiency

+ Typically ISO 14644-1

TSI Product Overview

Certification

7

Page 7: PRODUCT LINE OVERVIEW - Vectus€¦ · © TSI Incorporated 10/20/2016 TSI CONFIDENTIAL + 0.1 CFM, 3-6 Channels + 0.3 µm -10 µm + On board memory TSI Product Overview 930X Handheld

10/20/2016 © TSI Incorporated

TSI CONFIDENTIAL

+ 6 channels

+ 0.3 m to 25 m particle detection

+ 1 CFM to 100 l/min flow rates

+ ISO 14644 report generation

+ On board memory

+ TrakPro Lite Secure data download

TSI Product Overview

9XXX Portables

8

Model

Minimum Particle

Size Flow

9310 0.3 m 1.0 cfm (28.3 lpm)

9350 0.3 m 50 lpm

9550 0.5 m 50 lpm

9500 0.5 m 100 lpm

Page 8: PRODUCT LINE OVERVIEW - Vectus€¦ · © TSI Incorporated 10/20/2016 TSI CONFIDENTIAL + 0.1 CFM, 3-6 Channels + 0.3 µm -10 µm + On board memory TSI Product Overview 930X Handheld

10/20/2016 © TSI Incorporated

TSI CONFIDENTIAL

Flow Rate & Sample Time

9

Sample Time per Location (minutes)

EU GMP Annex 1

Grade Class Limit

Volume (l)

0.1 cfm (2.83

l/min)

1.0 cfm (28.3

l/min)

1.7 cfm (50

l/min)

3.5 cfm (100

l/min)

A 20 1000 353 35 20 10

B 29 6890 244 24 14 7

C 2900 6.9 2 1 1 1

D 29000 0.69 1 1 1 1

+ For 5.0 m particles

+ 𝑉𝑜𝑙𝑢𝑚𝑒(𝑙) =20

𝐶𝑙𝑎𝑠𝑠 𝐿𝑖𝑚𝑖𝑡∗ 1000

Page 9: PRODUCT LINE OVERVIEW - Vectus€¦ · © TSI Incorporated 10/20/2016 TSI CONFIDENTIAL + 0.1 CFM, 3-6 Channels + 0.3 µm -10 µm + On board memory TSI Product Overview 930X Handheld

10/20/2016 © TSI Incorporated

TSI CONFIDENTIAL

+ Continuous Monitoring for cleanroom environments (clean zones) for electronics industry

+ 8 channels

+ 0.100µm to 10.0µm particle detection

+ 1.0 CFM (28.3L/min) sample flow rate

+ ISO 14644 report generation

+ On board memory

+ TrakPro Lite Secure data download

TSI Product Overview

9110 Portable

10

Page 10: PRODUCT LINE OVERVIEW - Vectus€¦ · © TSI Incorporated 10/20/2016 TSI CONFIDENTIAL + 0.1 CFM, 3-6 Channels + 0.3 µm -10 µm + On board memory TSI Product Overview 930X Handheld

10/20/2016 © TSI Incorporated

TSI CONFIDENTIAL

Portable Instrument

Components

11

+ Passivated stainless steel case • Non-shedding

• Easy to clean / disinfect

Page 11: PRODUCT LINE OVERVIEW - Vectus€¦ · © TSI Incorporated 10/20/2016 TSI CONFIDENTIAL + 0.1 CFM, 3-6 Channels + 0.3 µm -10 µm + On board memory TSI Product Overview 930X Handheld

10/20/2016 © TSI Incorporated

TSI CONFIDENTIAL

Using Portables and

Handhelds

12

Measurements

Start Sampling

Zone

Location

Sample Data

Page 12: PRODUCT LINE OVERVIEW - Vectus€¦ · © TSI Incorporated 10/20/2016 TSI CONFIDENTIAL + 0.1 CFM, 3-6 Channels + 0.3 µm -10 µm + On board memory TSI Product Overview 930X Handheld

10/20/2016 © TSI Incorporated

TSI CONFIDENTIAL

Zones Setup

Identify and save the location information associated with collected samples.

Recipes Setup

Save a group of settings (a recipe) that you use over and over so you don’t have to reset individual settings.

Environment Setup

Sets which units are preferred for displaying environmental measurements taken using optional measurement probes.

System Setup

Change Power On Password, Setup Password, System Configuration, Print Settings, Print Schedule and Clear Samples

Purge Purge residual particles from flow path.

Info Display instrument information such as model number, firmware version, serial number, etc.

Device Setup

Set Date and Time, Screen Alignment, Communications, Regional Settings, and get device information.

Using Portables and

Handhelds

13

Page 13: PRODUCT LINE OVERVIEW - Vectus€¦ · © TSI Incorporated 10/20/2016 TSI CONFIDENTIAL + 0.1 CFM, 3-6 Channels + 0.3 µm -10 µm + On board memory TSI Product Overview 930X Handheld

10/20/2016 © TSI Incorporated

TSI CONFIDENTIAL

Using Portables and

Handhelds

14

Change Units

Export Data

Print Data

Page 14: PRODUCT LINE OVERVIEW - Vectus€¦ · © TSI Incorporated 10/20/2016 TSI CONFIDENTIAL + 0.1 CFM, 3-6 Channels + 0.3 µm -10 µm + On board memory TSI Product Overview 930X Handheld

10/20/2016 © TSI Incorporated

TSI CONFIDENTIAL

Using Portables and

Handhelds

15

Standard

Class

Exclude Data

Zone

Generate Report

Page 15: PRODUCT LINE OVERVIEW - Vectus€¦ · © TSI Incorporated 10/20/2016 TSI CONFIDENTIAL + 0.1 CFM, 3-6 Channels + 0.3 µm -10 µm + On board memory TSI Product Overview 930X Handheld

10/20/2016 © TSI Incorporated

TSI CONFIDENTIAL

TSI Product Overview

TrakPro Lite Secure

+ Data download software for portable and handheld devices

+ Create, modify, delete, and export AeroTrak zones, recipes, and sample point names

+ Manage large quantities of data

+ Report Generation

+ Enables 21CFR Part 11 compliance

16

Page 16: PRODUCT LINE OVERVIEW - Vectus€¦ · © TSI Incorporated 10/20/2016 TSI CONFIDENTIAL + 0.1 CFM, 3-6 Channels + 0.3 µm -10 µm + On board memory TSI Product Overview 930X Handheld

10/20/2016 © TSI Incorporated

TSI CONFIDENTIAL

17

Testing Monitoring

Page 17: PRODUCT LINE OVERVIEW - Vectus€¦ · © TSI Incorporated 10/20/2016 TSI CONFIDENTIAL + 0.1 CFM, 3-6 Channels + 0.3 µm -10 µm + On board memory TSI Product Overview 930X Handheld

10/20/2016 © TSI Incorporated

TSI CONFIDENTIAL

+ Continuous Monitoring for cleanroom environments (clean zones) for pharmaceuticals, medical devices, semi-conductor, aerospace, etc.

TSI Product Overview

Monitoring

18

Page 18: PRODUCT LINE OVERVIEW - Vectus€¦ · © TSI Incorporated 10/20/2016 TSI CONFIDENTIAL + 0.1 CFM, 3-6 Channels + 0.3 µm -10 µm + On board memory TSI Product Overview 930X Handheld

10/20/2016 © TSI Incorporated

TSI CONFIDENTIAL

+ REQUIRES Central vacuum system

+ 2 – 4 channels

+ 0.2 – 5.0µm particle detection

+ 0.1 or 1.0 CFM (2.83 or 28.3 L/min) sample flow rate

+ VHP-resistant models available

TSI Product Overview

7xxx Remote

19

Page 19: PRODUCT LINE OVERVIEW - Vectus€¦ · © TSI Incorporated 10/20/2016 TSI CONFIDENTIAL + 0.1 CFM, 3-6 Channels + 0.3 µm -10 µm + On board memory TSI Product Overview 930X Handheld

10/20/2016 © TSI Incorporated

TSI CONFIDENTIAL

+ REQUIRES Central vacuum system

+ 0.100 – 10.0µm particle detection

+ 8 channels

+ 1.0 CFM (28.3L/min) sample flow rate

+ For electronics industry

TSI Product Overview

7110 Remote

20

Page 20: PRODUCT LINE OVERVIEW - Vectus€¦ · © TSI Incorporated 10/20/2016 TSI CONFIDENTIAL + 0.1 CFM, 3-6 Channels + 0.3 µm -10 µm + On board memory TSI Product Overview 930X Handheld

10/20/2016 © TSI Incorporated

TSI CONFIDENTIAL

+ Central vacuum system not required

+ VHP-resistant model available

+ 4 measurement channels

+ 0.3 – 5.0µm particle detection

+ 1.0 CFM (28.3 L/min) sample flow rate

+ 4 analog inputs

+ 2 analog outputs

TSI Product Overview

6x10 Remote with Pump

21

Page 21: PRODUCT LINE OVERVIEW - Vectus€¦ · © TSI Incorporated 10/20/2016 TSI CONFIDENTIAL + 0.1 CFM, 3-6 Channels + 0.3 µm -10 µm + On board memory TSI Product Overview 930X Handheld

10/20/2016 © TSI Incorporated

TSI CONFIDENTIAL

+ Monitor viable particulate levels in real-time

+ Takes place of traditional active air sampling methods

+ Test, monitor and certify cleanroom environments (clean zones) for pharmaceuticals

+ 6 channels

+ 0.5 – 25µm particle detection

+ 1.0 CFM (28.3 L/min) sample flow rate

TSI Product Overview

9510-BD BioTrak

22

Page 22: PRODUCT LINE OVERVIEW - Vectus€¦ · © TSI Incorporated 10/20/2016 TSI CONFIDENTIAL + 0.1 CFM, 3-6 Channels + 0.3 µm -10 µm + On board memory TSI Product Overview 930X Handheld

10/20/2016 © TSI Incorporated

TSI CONFIDENTIAL

TSI Product Overview

FMS

23

Facility Monitoring Software

+ Monitoring software suite

+ Database

+ Hot standby failover

+ Device integration (multiple manufacturers supported)

+ Highly scalable

+ Fully GAMP compliant

+ Enables 21CFR Part 11 compliance

Page 23: PRODUCT LINE OVERVIEW - Vectus€¦ · © TSI Incorporated 10/20/2016 TSI CONFIDENTIAL + 0.1 CFM, 3-6 Channels + 0.3 µm -10 µm + On board memory TSI Product Overview 930X Handheld

10/20/2016 © TSI Incorporated

TSI CONFIDENTIAL

24

Page 24: PRODUCT LINE OVERVIEW - Vectus€¦ · © TSI Incorporated 10/20/2016 TSI CONFIDENTIAL + 0.1 CFM, 3-6 Channels + 0.3 µm -10 µm + On board memory TSI Product Overview 930X Handheld

10/20/2016 © TSI Incorporated

TSI CONFIDENTIAL

TSI Product Overview

Model number system

9 3 1 0

Model

9 – portable

7 – remote

6 – remote with pump

Smallest particle

channel

1 – 0.1µm

2 – 0.2µm

3 – 0.3µm

5 – 0.5µm

Sample Flow Rate

01 – 0.1 CFM (2.83L/min)

10 – 1.0 CFM (28.3L/min)

50 – 1.77 CFM (50L/min)

00 – 3.53 CFM (100L/min)

Exceptions

03 – 9303 Handheld

06 – 9306 Handheld

25

Page 25: PRODUCT LINE OVERVIEW - Vectus€¦ · © TSI Incorporated 10/20/2016 TSI CONFIDENTIAL + 0.1 CFM, 3-6 Channels + 0.3 µm -10 µm + On board memory TSI Product Overview 930X Handheld

10/20/2016 © TSI Incorporated

TSI CONFIDENTIAL

TSI Product Overview

Model number system

7 2 0 1

Model

9 – portable

7 – remote

6 – remote with pump

Smallest particle

channel

1 – 0.1µm

2 – 0.2µm

3 – 0.3µm

5 – 0.5µm

Sample Flow Rate

01 – 0.1 CFM (2.83L/min)

10 – 1.0 CFM (28.3L/min)

50 – 1.77 CFM (50L/min)

00 – 3.53 CFM (100L/min)

26

Page 26: PRODUCT LINE OVERVIEW - Vectus€¦ · © TSI Incorporated 10/20/2016 TSI CONFIDENTIAL + 0.1 CFM, 3-6 Channels + 0.3 µm -10 µm + On board memory TSI Product Overview 930X Handheld

10/20/2016 © TSI Incorporated

TSI CONFIDENTIAL

TSI Product Overview

Model number system

9 5 0 0

Model

9 – portable

7 – remote

6 – remote with pump

Smallest particle

channel

1 – 0.1µm

2 – 0.2µm

3 – 0.3µm

5 – 0.5µm

Sample Flow Rate

01 – 0.1 CFM (2.83L/min)

10 – 1.0 CFM (28.3L/min)

50 – 1.77 CFM (50L/min)

00 – 3.53 CFM (100L/min)

27

Page 27: PRODUCT LINE OVERVIEW - Vectus€¦ · © TSI Incorporated 10/20/2016 TSI CONFIDENTIAL + 0.1 CFM, 3-6 Channels + 0.3 µm -10 µm + On board memory TSI Product Overview 930X Handheld

10/20/2016 © TSI Incorporated

TSI CONFIDENTIAL

TSI Product Overview

Model number system

9 3 0 6

Model

9 – Handheld

Smallest particle

channel

3 – 0.3µm

# of Channels

03 – 3 channels

06 – 6 channels

28

Page 28: PRODUCT LINE OVERVIEW - Vectus€¦ · © TSI Incorporated 10/20/2016 TSI CONFIDENTIAL + 0.1 CFM, 3-6 Channels + 0.3 µm -10 µm + On board memory TSI Product Overview 930X Handheld

10/20/2016 © TSI Incorporated

TSI CONFIDENTIAL

Conclusion

29

TSI has handheld, portable and remote instruments

Model numbers give sample flow rate and minimum particle size

You can win with TSI products