ATEX Example
Fluke 707Ex is ATEX Compliant II 2 G EEx ia IIC T4The ATEX examination mark is required on all devices for use in European hazardous areas.
ATEX MarkingsII 2 G Theclassificationofzones.“II”designatesthetoolisapprovedforall
non-miningareas.“2”representsthecategoryofthedevice,inthiscasethedeviceisratedforthesecondmosthazardousareas.“G”designatesatmosphere,inthiscasegas,vaporsandmist.
EEx ExplosionprotectionbasedonEuropeanEx-regulations.ia Thetypeofprotectionfromexplosion,inthiscasetheenergyinadeviceor
connectorhasbeenreducedtoasafevalue.IIC GasGroup.“IIC”ratingindicatescompatibilitywiththemostdangerous
gasgroups.T4 Temperatureclassisthemaximumtemperatureofasurfacethatmaybe.
FM Example
Fluke 707Ex is FM-classified N.I. Class I, Div 2, Groups A-
D, T4
The Factory Mutual Approved mark.
Factory Mutual MarkingsN.I. Non-incendiveapparatus,internalenergyislimitedsoaspecified
atmospherecannotbeignitedbyitsuse.Class I Forusewithgases,vaporsandliquids(notdust,fibersorfilings).Div 2 CertifiedforuseinZone2,explosiveatmospheresnotnormallypresent,
mayrarelyexistforshortduration.Groups RatedforusewithexplosivegassesasdefinedbygroupsA-D,A-D includingacetylene,hydrogen,acetyleneandpropane.
You need to meet
tough maintenance
and calibration tasks
in potentially explo-
sive and hazardous
areas. That means
you need reliable,
accurate and intrinsi-
cally safe tools.
The complete line of
Fluke tools includes
the NEW 87V Ex
True-RMS Multimeter
and the NEW
Fluke 68IS Infrared
Thermometer to
compliment the line
of Fluke intrinsically
safe field calibrators.
Read on to find out
more about why
intrinsic safety is
important, how Fluke
Intrinsically Safe tools
can be used in your
work and whether
you need intrinsically
safe tools in your job.
Fluke 700PExPressure Modules
Fluke 718Ex Pressure Calibrator
Fluke 707Ex Loop Calibrator
Fluke 68IS Infrared
Thermometer
Fluke 87Ex True-RMS Industrial
Multimeter
Fluke 725Ex Multifunction
Process Calibrator
Making sense of the product rating systemsEach approved intrinsically safe device is rated to ATEX and either NEC or Factory Mutual (FM) Standards. The corresponding rating system allows you to understand which zones, type of protection, gas groups and tem-perature classes the instrument is approved for.
Fluke CorporationPOBox9090,Everett,WAUSA98206
FlukeEuropeB.V.POBox1186,5602BDEindhoven,TheNetherlands
Formoreinformationcall:IntheUSA(800)443-5853orFax(425)446-5116InEurope/M-East/Africa(3140)2675200orFax(3140)2675222InCanada(800)36-FLUKEorFax(905)890-6866Fromothercountries+1(425)446-5500orFax+1(425)446-5116Webaccess:http://www.fluke.com
©2005FlukeCorporation.Allrightsreserved.PrintedinU.S.A.9/20052432675B-EN-NRevB
Fluke.Keeping your world up and running.
Fluke tools designed to keep you safe in
dangerous environments
Take this quiz and find out if you need I.S. tools on your job.
1) Doyouworkinanyoftheseindustries?
a.Petro-chemicalb.Oilplatformsandrefineries
c.Mining d.Pharmaceutical e.Pipelines(Naturalgas,oil,etc.) f. Powergeneration g.Grainhandling
2)Doyouworkwhereexplosivegasesmaybepresent?
a.Yesb.No
3)Doyouworkinthetransportorworkinanenvironmentwithanyofthesesubstances?
a.Acetyleneb.Ethylene
c.Gasoline d.Benzol e.Naturalgas f. Heatingoil/diesel g.Methane h.Propane i. Carbondisulphide j. Hydrogen
If you answered yes to any of these questions, please review the products in this brochure and the specific zones, types of protection, gas groups and temperature classes each instrument is approved for.
Fluke 725Ex Multifunction Process Calibrator
Bestsuitedfor:
• Calibratingvirtuallyanyprocessparameter
Features:
• ClassIDiv1GroupsB-D171°C
• ATEXIIIGEExiaIIB171°CCompliant
• Measure,sourceorsimulatevoltsdc,mA,RTDs,thermocouples,frequencyandohms
• 2-channelsimultaneoussourceandmeasurecapabilityforcalibrationoftransmitters
• Internalloopsupplytopowertransmitters
• Storefrequently-usedtestsetupsforlateruse
• Pressuremeasurementto200barandpressureswitchtestusinganyofthe8Fluke700PExpressuremodules
Fluke 700PEx Pressure Modules
Bestsuitedfor:
• UsewiththeFluke725ExMultifunctionalProcessCalibratorandFluke718ExPressureCalibratortocoverthemostcommonlyusedpressurecalibrationrangesfrom0-25mbarand0-200bar
Features:
• I.S.ClassIDiv1GroupsA-DT4,Ta=0°Cto+50°C
• ATEXII1GEExiaIICT4compliant
• Veryhighaccuracyupto0.025%
Fluke 68 Intrinsically Safe Infrared Thermometer
Bestsuitedfor:
• Takingspot,differentialorscanningtemperaturemeasurementsin
anyenvironmentwhereflammablegasesorvaporsmaybepresent.
Features:• Enhancedoptics(distancetospotratioupto50:1)allowtheuserto
measuresmallerobjectsfromfartheraway• FactoryMutual(aU.S.organization)approvedasanIntrinsicallySafe
device(ClassI,Division1) (CustomersoutsideoftheUnitedStatesshouldcheckwiththeirnationalandcompany
regulationstoseeifwhichapprovalsareacceptablefortheirapplication.)
• Comfortablepistolgripmaketargetpointingandeasyjob• Backlitdisplayforpoorlylitareas• DisplaysMin/Maxmeasurementsandsavesreadingsinmemory• Adjustableemissivitysettingformoreaccuratemeasurements• Logupto12measurements• RTDcontactprobe
Fluke 707Ex Loop Calibrator
Bestsuitedfor:
• Calibrationandmaintenanceof4to20mAcontrolloop
Features:
• F.M.ClassIDiv2GroupsA-DT4
• ATEXII2GEExiaIICT4compliant
• Largedisplayandsimple,quick-clickpush/rotarybuttonforeasyone-handedoperation
• SimultaneousmAand%readoutforquick,easyinterpretationofreadings
• mAaccuracyof0.015%,superiortootherloopcalibrators
• Pushbuttonwith25%stepsforfast,easylinearitychecks
• 0and100%‘spancheck’forfastconfirmationofzeroandspan
LegendMotorControlCenter ProcessMeasurementsFlowComputer ProcessController
TankFarm PumpingStation
For more information on these ATEX-compliant tools designed for tough process maintenance and calibration tasks, visit www.fluke.com/ex
Fluke Intrinsically Safe products to help keep your employees safe
Fluke 87VEx Industrial
Bestsuitedfor:
• Solvingproblemsonmotordrives,inplantautomation,powerdistributionandelectro-mechanicalequipment
Features:
• Measureaccuratevoltageandfrequencymeasurementsonadjustablespeedmotordrivesandotherelectricallynoisyequip-ment
• Built-inthermometerallowsyoutotaketemperaturereadings
• Optionalmagnetichangerforeasyset-upandviewingwhilefreeingyourhandsforothertasks
• Largedigitdisplaywithbright,two-levelbacklight
Bestsuitedfor:
• Pressuremeasurementsandcalibrationinpressurerangesupto200bar
Features:
• ClassIDiv1GroupsA-DT4Compliant
• ATEXIIIGEExiaIICT4compliant
• Built-inpressure/vacuumhandpump,withvernierandbleedvalve
• Pressuremeasurementto200barusinganyofthe8Fluke700PExPressureModules
• Pressuremeasurementto0.05%offullspanusinginternalpressuresensor
• Pressureswitchtestfunction
“Intrinsically Safe” or I.S. is a protection method employed in potentially explosive atmo-spheres. Certified I.S. tools are designed to prevent the release of sufficient energy to cause ignition of flammable mate-rial. I.S. standards apply to all equipment that can create one or more of a range of defined potential explosion sources:
• Electrical sparks
• Electrical arcs
• Flames
• Hot surfaces
• Static electricity
• Electromagnetic radiation
• Chemical reactions
• Mechanical impact
• Mechanical friction
• Compression ignition
• Acoustic energy
• Ionizing radiation
Industries that use or should use I.S. tools include:
• Petro-chemical
• Oil platforms and refineries
• Pharmaceutical
• Pipelines
• Any environment where explosive gases or vapors could be present