PRODUCT SECTION LOCATORSECTION PAGES
1 Hook-Up Wire 1-7
2 Communication & Control Cable, Multi-Conductor 8-28
3 Communication & Control Cable, Multi-Paired 29-37
4 Computer Cable 38-55
5 Coaxial Cable 56-83
Carol® Brand Alarm and Security Solutions Guide 84-85
6 Fire Alarm/Life Safety Cable 86-96
7 Sound, Alarm & Security Cable 97-107
8 Plenum Cable 108-118
9 Audio/Video & Broadcast Cable 119-158
10 Industrial Ethernet Cable 159-166
11 Specialty Cable 167-171
12 CSA Approved Cable 172-181
13 Technical Information 182-238
SECTION PAGE
1 Hook-Up Wire 1-7
UL 1007, UL 1569, CSA TR-64 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2UL 1015, CSA TEW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3MIL-W-76B . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4MTW, TFF, AWM, CSA TEW, THW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-6Rubber/PVC Test Lead. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
2 Communication & Control Cable, Multi-Conductor 8-28
Multi-Conductor, Unshielded . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-14Power-Limited Tray Cable, Unshielded . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15Multi-Conductor, Rubber, Unshielded . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 Multi-Conductor, Foil Shield . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17-19Power-Limited Tray Cable, Foil Shield. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20Multi-Conductor, Spiral Shield . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21Multi-Conductor, Braid Shield . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22-25Multi-Conductor, Foil/Braid Shield. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26Multi-Conductor, Rubber, Braid Shield . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27Multi-Conductor, Carolprene®, Braid Shield . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
3 Communication & Control Cable, Multi-Paired 29-37
Multi-Paired, Unshielded . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30-31Multi-Paired, Foil Shield . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32-33Power-Limited Tray Cable, Foil Shield. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34Multi-Paired, Individually Shielded. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35-36Power-Limited Tray Cable, Individually Shielded . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
4 Computer Cable 38-55
Multi-Conductor, Foil Shield . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39-40Multi-Conductor, Foil/Braid Shield . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41-42Multi-Conductor, Foil/Braid Shield, Lo-Cap® . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43Multi-Paired, Foil Shield . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44Multi-Paired, Foil Shield, Lo-Cap® . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45Multi-Paired, Foil/Braid Shield . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46Multi-Paired, Foil/Braid Shield, Lo-Cap® . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47-50Multi-Paired, Individually Foil Shielded . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51-53Multi-Paired, Individually Foil Shielded, Lo-Cap®. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54Multi-Paired, Individually Foil/Braid Shielded, Lo-Cap® . . . . . . . . . . . . . . . . . . . . . . . . . . 55
Table of Contents
Table of ContentsSECTION PAGE
5 Coaxial Cable 56-83
Carol® Brand CoaxialRG 6/U Type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57-60RG 7/U Type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61RG 8/U Type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62RG 11/U Type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63-64RG 58/U Type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65RG 59/U Type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66-69RG 62/U Type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70RG 174/U Type and RG 213/U Type. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71Other Coaxial Cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72Twinaxial Cables. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73Helix/HiTemp™ Brand CoaxialRG 6 & RG 11 Broadband Quad Shield Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75RG 8/U Type Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 76RG 8/U Type Thicknet/Trunk Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77RG 58/U Type Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 78-79RG 58/U Type Thinnet Cable. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80Headend CATV Drop Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81Headend Tinned Copper Drop Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82RG 213, RG 214, RG 174 Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83
Carol® Brand Alarm and Security Solutions Guide 84-85
6 Fire Alarm/Life Safety Cable 86-96
Multi-Conductor, Unshielded, Non-Plenum. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 87Multi-Conductor, Shielded, Non-Plenum . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 88Multi-Conductor, Unshielded, Plenum. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 89Multi-Conductor, Shielded, Plenum . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 90Multi-Conductor, Unshielded, Plenum, PVDF Jacketed . . . . . . . . . . . . . . . . . . . . . . . . . . 91Multi-Conductor, Shielded, Plenum, PVDF Jacketed . . . . . . . . . . . . . . . . . . . . . . . . . . . 92Mid-Capacitance, Unshielded, Non-Plenum . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 93Mid-Capacitance, Shielded, Non-Plenum . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 94Mid-Capacitance, Unshielded, Plenum . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 95Mid-Capacitance, Shielded, Plenum . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 96
SECTION PAGE
7 Sound, Alarm & Security Cable 97-107
Multi-Conductor, Unshielded, Riser . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 98Multi-Conductor, Shielded, Riser . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 99Multi-Conductor, Unshielded, Plenum . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100Multi-Conductor, Shielded, Plenum . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 101Antenna Rotor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 102Telephone Station/Intercom & Speaker/Burglar Alarm . . . . . . . . . . . . . . . . . . . . . . . . . . 103Low-Voltage Sprinkler Wire . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 104Thermostat Wire Type LVT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 105Thermostat Wire Type CL2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 106Thermostat Wire, Unjacketed. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 107
8 Plenum Cable 108-118
Multi-Conductor, Unshielded . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 109-110Multi-Conductor, Foil Shield . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 111-112Multi-Paired, Foil Shield . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 113-114Multi-Paired, Foil Shield, Mid-Cap . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 115Multi-Paired, Foil Shield, Lo-Cap® . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 116Multi-Paired, Individually Foil Shielded . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 117NEC Article 725, Article 800, Coaxial Cable, Plenum . . . . . . . . . . . . . . . . . . . . . . . . . . 118
Table of Contents
SECTION PAGE
9 Audio/Video & Broadcast Cable 119-10
SMPTE-311 Hybrid Fiber Optic/Copper Camera Cable . . . . . . . . . . . . . . . . . . . . . . . . . 120Electronic News Gathering/Field Production Camera Cable. . . . . . . . . . . . . . . . . . . . . . . 121RG 6/U Multi-Channel Digital/Precision Cable. . . . . . . . . . . . . . . . . . . . . . . . . . . . 122-123RG 6 & RG 7 Serial Digital Interface/Precision Cable . . . . . . . . . . . . . . . . . . . . . . . . . . 124RG 11 Serial Digital Interface (SDI) Precision Cable. . . . . . . . . . . . . . . . . . . . . . . . . 125-126RG 59/U (RGB) Multi-Channel Digital/Precision Cable . . . . . . . . . . . . . . . . . . . . . . . . . . 127RG 59 & RG 11 Camera Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 128-129RG 59/U Precision & Miniature Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 130RG 59/U (RGB) Miniature Multi-Channel Precision Cable . . . . . . . . . . . . . . . . . . . . . 131-132RG 59 Serial Digital Interface Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 133-134Ultra Flexible Low Impedence 4-Conductor “Star-Quad” Microphone Cable . . . . . . . . . . . . . 135Ultra Flexible Low Impedence 2-Conductor Microphone Cable. . . . . . . . . . . . . . . . . . . . . 136Multi-Conductor, Spiral Shield . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 137Multi-Conductor, Flexfoil® Shield . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 138Multi-Conductor, Braid Shield . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 139Multi-Conductor, Rubber, Braid Shield . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 140Multi-Conductor, Carolprene®, Braid Shield . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 141Special Audio, Communication & Instrumentation . . . . . . . . . . . . . . . . . . . . . . . . . 142-144CCTV Coaxial, TV Camera & Video Surveillance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 145Direct Burial, Audio & Communication . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 146-147Analog Audio Snake Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 148-149Digital Audio Snake Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 150-151Speaker Wire . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 152-153Superflex® Speaker Wire . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 154Command Series® Speaker Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 155-157Guitar/Instrument Cable. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 158
10 Industrial Ethernet Cable 159-166
ToughCat™ 100E Category 5e UTP Data Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 160ToughCat™ 100E Dual Jacket Category 5e UTP Data Cable . . . . . . . . . . . . . . . . . . . . . . 161ToughCat™ 100E Shielded Category 5e ScTP Data Cable . . . . . . . . . . . . . . . . . . . . . . . 162ToughCat™ 100E Dual Shielded Category 5e S/FTP Data Cable . . . . . . . . . . . . . . . . . . . . 163ToughCat™ 1000 Category 6 UTP Data Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 164ToughCat™ 1000 Dual Jacket Category 6 UTP Data Cable . . . . . . . . . . . . . . . . . . . . . . . 165ToughCat™ 7000 Shielded Category 7 (Draft) S/STP Data Cable . . . . . . . . . . . . . . . . . . . 166
Table of Contents
SECTION PAGE
11 Specialty Cable 167-171
SmartWrap™ Bundled Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 168Fluorobus Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 169Fire Wire . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 170Computer Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 171
12 CSA Approved Cable 172-181
Multi-Conductor, Unshielded . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 173-175Multi-Conductor, Foil Shield . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 176-177Multi-Paired, Foil Shield . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 178-179Multi-Conductor, Foil Shield . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 180Multi-Paired, Individually Shielded . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 181
13 Technical Information 182-238
Insulation & Jacket Properties . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 183Decimal Conversion Factors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 184Unit Conversion Factors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 185Temperature Conversion Chart . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 186Conduit Capacity Chart . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 187Coax Connector Cross Reference . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 188-195AWG Conductor Chart . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 196Cable Design Equations—Braid Shield . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 197Cable Design Equations—Coaxial Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 198Cable Design Equations—Balanced Pair . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 199Engineering Prefixes. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 200Glossary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 201-211Abbreviations & Acronyms. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 212-214Product Finder—Hook-Up Wire . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 215Product Finder—Multi-Conductor Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 216-218Product Finder—Multi-Paired Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 219-220NEC Substitution Chart . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 221-222Agency Symbols . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 223Put-Ups and Color Codes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 224Product Description Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 225-227Belden-to-General Cable Carol® Brand Cross Reference Index . . . . . . . . . . . . . . . . . . 228-233Part Number Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 234-236Notes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 237-238
Table of Contents
®
Now one industry leader focuses its worldwide resources on delivering maximum value to customers. It’s the cost-effective advantage of a singleresource, a single company that provides the broadest product range, the highestlevel of commitment to customer and technical support, the most cost-effectivemanufacturing and distribution, and the most responsive customer-first service.In today’s highly competitive worldwide markets, General Cable provides the single-source solution with benefits that go straight to your bottom line. Ask yourrepresentative about other General Cable products.
Energy CablesBare Overhead High-Voltage Transmission andDistribution Cables Our BICC Brand cables satisfy the varied and specializeddemands of the electrical utility marketplace. OurTransPowr™ bare aluminum overhead cables andPowrMax™ insulated high-voltage cables for buried applications are available in numerous combinations of aluminum and steel strands and layers. Our new aerial high-density transmission cables feature innovative compositecore construction.
Low- and Medium-Voltage Distribution CablesGeneral Cable’s extensive line of BICC Brand PowrServ™and EmPowr™ copper and aluminum cables serve the totaldistribution needs of electrical utilities, rural electrical co-ops and the public power market for both traditional and renewable energy resources.
Industrial & Specialty CablesAutomotive ProductsFrom ignition wire sets to battery starter cables and primary wire, our Carol Brand is the answer for the automotive aftermarket.
Cord and Mining CablesCarol Brand is the most recognized name in flexible cords.The extensive line includes portable cord, cordsets, portablepower cable and premium-grade cable for commercial andindustrial applications. Both our Carol and premier AnacondaBrand cables are built for rugged uses such as mining,welding and diesel locomotives.
Instrumentation, Power and Control CablesOur industrial and Brand Rex cables serve the factoryautomation, transit, marine, oil rig, petrochemical and military markets. We manufacture instrumentation traycables and automation cables for standard, specialized and custom applications. When uptime, reliability and performance are essential, customers count on our powercables—from low-voltage single-conductor to medium-voltage armored or unarmored.
Communications CablesData Communications CablesOur products are on the job wherever enhanced performanceis critical—from Gigabit Ethernet, token ring and broadbandapplications to patch panels, communications closets and plenum applications. We offer one of the most comprehensive lines of enhanced high-speed Category products, including GenSPEED 6000 and our PanGen™structured cabling system solutions.
Electronics CablesOur Carol and Helix/HiTemp Brand products fulfill the complete wire and cable requirements of the fast-changingelectronics, sound and security marketplaces. We offerhookup wire; communications cable; computer, coaxial andmicrophone cables; and special designs for security systems, fire alarms, and audio, video and digital broadcasts.
Fiber Optic CablesWe provide a full menu of NextGen Brand fiber optic cablesfor data communications and voice and video networks. Ourproducts range from tight buffer and armored products formilitary applications to loose tube and hybrid cables forcommunications networks. We also offer advanced Blolite™blown fiber systems for Local Area Networks and campusapplications.
Telecommunications CablesOur broad range of industry-standard outside plant wire andcable products ensures reliable, cost-effective performance.We provide air core, filled core and specialty wire productsfor aerial, buried and duct applications.
Wire Harnesses and AssembliesWe supply custom-designed cable, harnesses and assemblies for a wide variety of OEM applications, includingbusiness machines, material handling equipment, factoryautomation and medical equipment.
Electronics
FPO
Index Page
UL 1007, UL 1569,CSA TR-64 2
UL 1015, CSA TEW 3
MIL-W-76B 4
MTW Type WireMTW, TFF, AWM, CSA TEW, THW 5-6
Rubber/PVC Test Lead 7
1
Electronics
Hook-Up Wire 1
Most applications of hook-up and lead wire for board-to-board or point-to-point wiringrely on PVC-insulated designs.
General Cable’s Carol® Brandproducts offer both electricaland electronic designers a vastarray of quality PVC hook-upwire to meet the specifictechnical demands of today,with ‘‘off-the-shelf” distributorinventoried products.
Hook-up wire is alsoavailable in special colorsand/or stripe combinationswith a minimum of lead time. In addition, General Cableoffers a variety of put-ups tomeet individual customerrequirements.
2
Hook-Up Wire Electronics
Product Construction:Conductor:• 24 thru 16 AWG • Fully annealed tinned copper per
ASTM B-33• Solid or stranded
Insulation:• Premium-grade, coIor-coded PVC• Temperature range: –20˚C to +105˚C• Color Code: See chart below
Applications:• Internal wiring of electrical and electronic
equipment• Internal wiring of panels and meters• Point-to-point wiring• Suggested voltage rating: 300 volts
Compliances:• UL Style 1007 - 80˚C, 300V• UL Style 1569 - 105˚C, 300V• CSA TR-64 - 90°C, 300V• Designed to meet UL VW-1 Vertical Wire
Flame Test
Packaging:• Please contact Customer Service for
packaging and color options
UL 1007, UL 1569, CSA TR-64
CATALOGNUMBER
AWGSIZE
C2003C2004C2028C2052C2053
24
22
20
18
16
COND.STRAND.
Solid
Solid
Solid
Solid
Solid
NOM. INSULATIONTHICKNESS
INCHES
NOMINAL O.D.
0.016
0.016
0.016
0.016
0.016
mm
0.41
0.41
0.41
0.41
0.41
INCHES
0.052
0.057
0.064
0.072
0.083
mm
1.32
1.45
1.63
1.83
2.11
SOLID CONDUCTORS
C2015C2016C2040C2064C2065
24
22
20
18
16
7/32
7/30
10/30
16/30
26/30
0.016
0.016
0.016
0.016
0.016
0.41
0.41
0.41
0.41
0.41
0.056
0.062
0.070
0.080
0.092
1.42
1.57
1.78
2.03
2.34
STRANDED CONDUCTORS
Striped combinations available upon request, consult Customer Service.
Color Code Chart
0102030405
ORDERINGSUFFIX COLORS
BlackWhiteRedOrangeYellow
0607081019
ORDERINGSUFFIX COLORS
GreenBlueBrownGrayViolet
3
Electronics Hook-Up Wire
Product Construction:Conductor:• 24 thru 10 AWG • Fully annealed tinned copper per
ASTM B-33• Solid or stranded
Insulation:• Premium-grade, coIor-coded PVC• Temperature range: –20˚C to + 105˚C• Color Code: See chart below
Applications:• Internal wiring of electrical and electronic
equipment• Internal wiring of panels and meters• Point-to-point wiring• Suggested voltage rating: 600 volts
Compliances:• UL Style 1015 - 105°C, 600V• CSA Type TEW• Designed to meet UL VW-1 Vertical Wire
Flame Test
Packaging:• Please contact Customer Service for
packaging and color options
UL 1015, CSA TEW
CATALOGNUMBER
AWGSIZE
C2117C2118C2119
22
20
18
COND.STRAND.
Solid
Solid
Solid
NOM. INSULATIONTHICKNESS
INCHES
NOMINAL O.D.
0.032
0.032
0.032
mm
0.81
0.81
0.81
INCHES
0.089
0.096
0.104
mm
2.26
2.44
2.64
SOLID CONDUCTORS
C2100C2101C2102C2103C2104C2105C2106C2107
24
22
20
18
16
14
12
10
7/32
7/30
10/30
16/30
26/30
41/30
65/30
105/30
0.032
0.032
0.032
0.032
0.032
0.032
0.032
0.033
0.81
0.81
0.81
0.81
0.81
0.81
0.81
0.84
0.088
0.094
0.102
0.112
0.124
0.141
0.160
0.184
2.24
2.39
2.59
2.84
3.15
3.58
4.06
4.67
STRANDED CONDUCTORS
Striped combinations available upon request, consult Customer Service.
Color Code Chart
0102030405
ORDERINGSUFFIX COLORS
BlackWhiteRedOrangeYellow
0607081019
ORDERINGSUFFIX COLORS
GreenBlueBrownGrayViolet
4
Hook-Up Wire Electronics
Product Construction:Conductor:• 24 thru 12 AWG• Fully annealed stranded tinned copper per
ASTM B-33Insulation:• Premium-grade, coIor-coded PVC• Type MW: Medium wall• Temperature range:
– 12°C to +90°C• Color Code: See chart below
Applications:• Internal wiring of electrical and electronic
equipment• Internal wiring of panels and meters• Point-to-point wiring• Suggested voltage rating: 1000 volts
(MIL-W-76B)• Non QPL
Packaging:• Please contact Customer Service for
packaging and color options
MIL-W-76B Type MW
CATALOGNUMBER
TYPEDESIGNATION
C7600C7602C7604C7606C7608*C7610*C7611*
MW-C24(7)U
MW-C22(7)U
MW-C20(10)U
MW-C18(16)U
MW-C16(26)U
MW-C14(41)U
MW-C12(65)U
AWGSIZE
24
22
20
18
16
14
12
COND.STRAND.
7/32
7/30
10/30
16/30
26/30
41/30
65/30
0.016
0.016
0.016
0.016
0.016
0.016
0.016
0.41
0.41
0.41
0.41
0.41
0.41
0.41
0.056
0.062
0.070
0.080
0.092
0.109
0.128
NOM. INSULATIONTHICKNESS
1.42
1.57
1.78
2.03
2.34
2.77
3.25
MIL-W-76B TYPE MW (MEDIUM WALL)INCHES mm
NOMINAL O.D.
INCHES mm
Striped combinations available upon request, consult Customer Service.
Color Code Chart
0102030405
ORDERINGSUFFIX COLORS
BlackWhiteRedOrangeYellow
0607081019
ORDERINGSUFFIX COLORS
GreenBlueBrownGrayViolet
* – 25°C to +105°C
Product Construction:Conductor:• 18 through 8 AWG fully annealed
stranded bare copper per ASTM B-8
Insulation:• Premium-grade, coIor-coded PVC• Temperature Range:
MTW: -40ºC to +90ºCTEW/AWM: -20ºC to +105ºC
• Color Code: See chart below
Jacket Marking:• 18 and 16 AWG:
CAROL (SIZE) 600V E# MTW (UL) ORTFF OR AWM VW-1 --- CSA TEW 105ºCFT-1
• 14 through 8 AWG:CAROL (SIZE) 600V E# MTW (UL) ORAWM VW-1 --- CSA TEW 105ºC FT-1
Applications:• Motor and transformer lead• External wiring of machinery• Internal wiring of electrical and electronic
equipment• Internal wiring of panels and meters• Point-to-point wiring
Features:• Outstanding oil, flame and moisture
resistance• Extra flexible
Compliances:• UL and NMTBA Type MTW/AWM• CSA TEW• Passes VW-1 Vertical Flame Test• AWM Style 1015 – 18-8 AWG• AWM Style 1335 – 18-10 AWG• AWM Style 1336 – 8 AWG
Packaging:• Please contact Customer Service for
packaging and color options
UL Types MTW, TFF, AWM & CSA TEW90ºC 600 Volt MTW, TFF 105ºC 600 Volt AWM/TEW
765027651276812768227683276843
18
16
14
12
10
8
16/30
26/30
19/.0159
19/.0185
19/.0234
19/.0295
0.031
0.031
0.031
0.031
0.031
0.045
0.79
0.79
0.79
0.79
0.79
0.79
0.110
0.123
0.136
0.155
0.179
0.242
2.79
3.12
3.45
3.94
4.55
6.15
1-12
1-12
1-12
1-7
1-5
1-5
CATALOGNUMBER
AWGSIZE
COND.STRAND
NOM. INSULATIONTHICKNESS
INCHES mm INCHES mm
NOMINAL. O.D. STOCKCOLORS
UL TYPE MTW, AWM, TFF, CSA TYPE TEW – 600 VOLT
(S) Actual shipping weight may vary.
APPROX. NET WEIGHT
LBS/M'(S)
10
14
20
28
42
72
5
Electronics Hook-Up Wire
Color Code Chart
010203070605
ORDERINGSUFFIX COLORS
BlackWhiteRedBlueGreenYellow
040819101377
ORDERINGSUFFIX COLORS
OrangeBrownPurpleGrayPinkLight Blue
6
Hook-Up Wire Electronics
Heavy Wall UL Types MTW, AWM & NEC Type THW90ºC 600 Volts
Product Construction:Conductor:• 6 and 4 AWG fully annealed stranded
bare copper per ASTM B-8
Insulation:• Premium-grade, coIor-coded PVC, Black• Temperature Range: -40ºC to +90ºC
Jacket Marking:• CAROL 6 AWG 600V E# MTW OR THW
(UL) OR AWM
Applications:• Motor and transformer lead• External wiring of machinery
Features:• Outstanding oil, flame and moisture
resistance• Extra flexible
Compliances:• UL Type AWM• UL and NMTBA Type MTW• NEC Type THW• Passes UL VW-1 Vertical Flame Test
Packaging:• Please contact Customer Service for
packaging and color options
7695476994
6
4
19/.0372
19/.0469
0.060
0.060
1.52
1.52
0.315
0.365
8.00
9.27
CATALOGNUMBER
AWGSIZE
COND.STRAND
NOM. INSULATIONTHICKNESS
INCHES mm INCHES mm
NOMINAL. O.D.
AWM, MTW, THW – 600 VOLT – UL
(S) Actual shipping weight may vary.
APPROX.NET WEIGHT
LBS/M'(S)
110
150
Rubber Test Lead
PVC Test Lead
CATALOGNUMBER
NO. OFCOND.
AWGSIZE
COND.STRAND.
NOMINALO.D.
INCHES mm
C1326C1319C1321C1318
1
1
1
1
20
20
18
18
41/36
41/36
65/36
65/36
0.125
0.140
0.145
0.230
3.18
3.56
3.68
5.84
NOM. INSULATIONTHICKNESS
INCHES mm
0.040
0.047
0.045
0.088
1.02
1.19
1.14
2.24
Product Construction:Conductor:• 20 and 18 AWG• Fully annealed stranded tinned copper per
ASTM B-33Insulation:• Premium-grade, coIor-coded Rubber
or PVC• Temperature range:
–20˚C to +60˚C Rubber–25˚C to +60˚C PVC
• Color Code: See chart below
Applications:• Test equipment• Oscillators
Compliances:• RoHS Compliant Directive 2002/95/EC
Packaging:• Please contact Customer Service for
packaging and color options
Rubber/PVC Test Lead
BREAKDOWNVOLTAGE(AC, rms)
6,000V
12,000V
20,000V
29,000V
WORKINGVOLTAGE*
1,500V
3,000V
5,000V
10,000V
CATALOGNUMBER
NO. OFCOND.
AWGSIZE
COND.STRAND.
NOMINALO.D.
INCHES mm
C1320 1 18 65/36 0.140 3.56
NOM. INSULATIONTHICKNESS
INCHES mm
0.047 1.19
BREAKDOWNVOLTAGE(AC, rms)
20,000V
WORKINGVOLTAGE*
5,000V
*For intermittent duty only.
*For intermittent duty only.
Color Code Chart
0103
ORDERINGSUFFIX COLORS
BlackRed
Color Code Chart
010306
ORDERINGSUFFIX COLORS
BlackRedGreen
7
Electronics Hook-Up Wire
8
Electronics
The multi-conductor array ofcommunication and controlcable facilitates cable pull-insand single-site installations.
This cable is typically usedfor industrial equipmentcontrol, electric valve actuationand remote signaling, as wellas communications andbroadcast applications. Thesedesigns are available in a widevariety of insulation andjacketing materials, as well asshield designs to alleviateunwanted circuit noise.
General Cable’s Carol®Brand products aremanufactured to meet thelatest UL, CSA and NECrequirements and approvals.
A Design To Meet EveryApplication
PVC/PVC designs employpolyvinyl chloride insulationsand jackets capable of meetingeveryday, general purposeapplications.
PE or PP/PVC designsemploy high qualitypolyethylene or polypropyleneinsulations to assure faithfulreproduction of transmittedsignals across interconnectioncircuits.
Foamed PP/PVC designsuse high speed, foamedpolypropylene insulations forlong distance, critical circuits,which would not perform ifhigher loss insulations wereemployed.
Rubber/Rubber is typicallyemployed in installationscharacterized as severelyhostile environments, wherethese designs provideunsurpassed service life.
Rubber/Carolprene® offersthe ultimate performance forapplications that demand thegreatest protection from theenvironment, includingphysical abuse. The speciallyformulated Carolprene® jackethas been proven time andagain to withstand all types ofabuse, both mechanical andchemical.
Index PageMulti-Conductor,Unshielded 9-14Power-Limited TrayCable, Unshielded 15Multi-Conductor, Rubber,Unshielded 16Multi-Conductor,Foil Shield 17-19Power-Limited Tray Cable,Foil Shield 20Multi-Conductor, Spiral Shield 21Multi-Conductor, Braid Shield 22-25Multi-Conductor, Foil/BraidShield 26Multi-Conductor, Rubber,Braid Shield 27Multi-Conductor, Carolprene,®Braid Shield 28
Communication & Control Cable, Multi-Conductor 2
9
Electronics Communication & Control Cable, Multi-Conductor
CATALOGNUMBER
NO. OFCOND.
AWGSIZE
COND.STRAND.
NOM. INSULATIONTHICKNESS
INCHES
C4008
C4311
C2754
2
2
2
22
20
19
Solid
Solid
Solid
mm
0.010
0.010
0.010
0.25
0.25
0.25
NOM. JACKETTHICKNESS
INCHES mm
0.032
0.032
0.032
0.81
0.81
0.81
NOMINAL O.D.
NOM.C-C
CAP.*pF/ftINCHES mm
0.155
0.168
0.176
3.93
4.27
4.47
COLORCODE
Black/Red
Black/Red
Brown/Tan
25.0
28.0
29.5
Product Construction:Conductor:• Fully annealed tinned copper per
ASTM B-33• Fully annealed solid bare copper per
ASTM B-3, (C2754, C2755)
Insulation:• Premium-grade, coIor-coded S-R PVC
per UL 1061
Jacket:• PVC, gray• Temperature Range: –20°C to + 80°C
Applications:• Public address systems• Intercoms• Remote control circuits• Suggested voltage rating: 300 volts
Compliances:• NEC Article 800 Type CM (UL: 75°C)• UL Style 2464 (UL: 80°C 300V)• CSA CMG (CSA: 60°C)• Designed to meet UL 70,000 BTU Vertical
Tray Flame Test• Passes CSA CMG Flame Test
Packaging:• Please contact Customer Service for
packaging and color options
Multi-Conductor, UnshieldedUL 2464, NEC Type CM (UL) c(UL), CSA CMG
*Capacitance between conductors
19202122232425
10
Communication & Control Cable, Multi-Conductor Electronics
Multi-Conductor, UnshieldedUL 2464, UL 2576, NEC Type CM (UL) c(UL), CSA CMG
CATALOGNUMBER
NO. OFCOND.
AWGSIZE
COND.STRAND.
NOM. INSULATIONTHICKNESS
INCHES
C2461
C2462
C2463C2464C2466C2488C2465C2470C2471C2467C2473
2
3
4
5
6
7
8
9
10
12
15
24
24
24
24
24
24
24
24
24
24
24
7/32
7/32
7/32
7/32
7/32
7/32
7/32
7/32
7/32
7/32
7/32
mm
0.010
0.010
0.010
0.010
0.010
0.010
0.010
0.010
0.010
0.010
0.010
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
NOM. JACKETTHICKNESS
INCHES mm
0.032
0.032
0.032
0.032
0.032
0.032
0.032
0.032
0.032
0.032
0.032
0.81
0.81
0.81
0.81
0.81
0.81
0.81
0.81
0.81
0.81
0.81
NOMINAL O.D.
NOM.C-C
CAP.*pF/ftINCHES mm
0.156
0.163
0.174
0.187
0.200
0.200
0.214
0.227
0.244
0.251
0.275
3.96
4.14
4.42
4.75
5.08
5.08
5.44
5.77
6.20
6.38
6.99
COLORCODE
Black/Red
Black/Red/
Green
1
1
1
1
1
1
1
1
2
23.0
23.0
23.0
23.0
23.0
23.0
23.0
23.0
23.0
23.0
23.0
Product Construction:Conductor:• 24 AWG fully annealed stranded tinned
copper per ASTM B-33
Insulation:• Premium-grade, coIor-coded S-R PVC
per UL 1061• Color Code: See charts below
Jacket:• PVC, gray• Temperature Range: –20°C to +80°C
Applications:• Public address systems• Intercoms• Internal telephones • Remote control circuits• Suitable for EIA RS-232 applications• Suggested voltage rating: 300 volts
Features:• Easy to terminate• Excellent electrical properties • Tinned conductors provide excellent
corrosion resistance• Assists soldering applications
Compliances:• NEC Article 800 Type CM (UL: 75°C)• UL Style 2464 (UL: 80°C, 300V)• UL Style 2576 (UL: 80˚C, 150V)• CSA CMG (CSA: 60°C)• Designed to meet UL 70,000 BTU Vertical
Tray Flame Test• Passes CSA CMG Flame Test
Packaging:• Please contact Customer Service for
packaging and color options
*Capacitance between conductors
Color Code Chart 1 - For cables up to and including 12 conductors
123456
NO. OFCOND. COLOR
BlackWhiteRedGreenBrownBlue
789
101112
NO. OFCOND. COLOR
OrangeYellowVioletGrayPinkTan
Color Code Chart 2 Per ICEA - For cables of 15 thru 25 conductors
123456789
NO. OFCOND. COLOR
BlackWhiteRedGreenOrangeBlueWhite/BlackRed/BlackGreen/Black
101112131415161718
NO. OFCOND. COLOR
Orange/BlackBlue/BlackBlack/WhiteRed/WhiteGreen/WhiteBlue/WhiteBlack/RedWhite/RedOrange/Red
NO. OFCOND. COLOR
Blue/RedRed/GreenOrange/GreenBlack/White/RedWhite/Black/RedRed/Black/WhiteGreen/Black/White
11
Electronics Communication & Control Cable, Multi-Conductor
Product Construction:Conductor:• 22 AWG fully annealed, stranded tinned
copper per ASTM B-33
Insulation:• Premium-grade, coIor-coded S-R PVC
per UL 1061• Color Code: See charts below
Jacket:• PVC, gray• Temperature Range: –20°C to + 80˚C
Applications:• Public address systems• Intercoms• Internal telephones• Remote control circuits• Suitable for EIA RS-232 applications• Suggested voltage rating: 300 volts
Features:• Easy to terminate• Excellent electrical properties• Tinned conductors provide excellent
corrosion resistance• Assists soldering applications
Compliances:• NEC Article 800 Type CM (UL: 75°C)• UL Style 2464 (UL: 80°C, 300V)• UL Style 2576 (UL: 80˚C, 150V)• CSA CMG (CSA 80°C)• Designed to meet UL 70,000 BTU Vertical
Tray Flame Test• Passes CSA CMG Flame Test
Packaging:• Please contact Customer Service for
packaging and color options
Multi-Conductor, UnshieldedUL 2464, UL 2576, NEC Type CM (UL) c(UL), CSA CMG
CATALOGNUMBER
NO. OFCOND.
AWGSIZE
COND.STRAND.
NOM. INSULATIONTHICKNESS
INCHES
C6348†
C4062
C4063C4064C4066C4088C4065C4070C4071C4067C4073C4075C4076C4077C4078C4079
2
3
456789
1012152025304050
22
22
2222222222222222222222222222
7/30
7/30
7/307/307/307/307/307/307/307/307/307/307/307/307/307/30
mm
0.010
0.010
0.0100.0100.0100.0100.0100.0100.0100.0100.0100.0100.0100.0100.0100.010
0.25
0.25
0.250.250.250.250.250.250.250.250.250.250.250.250.250.25
NOM. JACKETTHICKNESS
INCHES mm
0.015
0.032
0.0320.0320.0320.0320.0320.0320.0320.0320.0320.0320.0320.0320.0320.032
0.38
0.81
0.810.810.810.810.810.810.810.810.810.810.810.810.810.81
NOMINAL O.D.
NOM.C-C
CAP.*pF/ftINCHES mm
0.130
0.176
0.1890.2030.2180.2180.2300.2490.2680.2760.3030.3340.3680.3890.4340.489
3.30
4.47
4.805.16 5.545.545.946.326.817.017.708.48 9.359.88
11.0212.42
COLORCODE
Black/Red
Black/Red/
Green111111 1122 2222
25.5
25.5
25.525.525.525.525.525.525.525.525.5 25.5 25.5 25.525.525.5
*Capacitance between conductors†CM-CSA CMG Only
Color Code Chart 2 Per ICEA - For cables of 15 thru 50 conductors
123456789
1011121314151617
NO. OFCOND. COLOR
BlackWhiteRedGreenOrangeBlueWhite/BlackRed/BlackGreen/BlackOrange/BlackBlue/BlackBlack/WhiteRed/WhiteGreen/WhiteBlue/WhiteBlack/RedWhite/Red
1819202122232425262728293031323334
NO. OFCOND. COLOR
Orange/RedBlue/RedRed/GreenOrange/GreenBlack/White/RedWhite/Black/RedRed/Black/WhiteGreen/Black/WhiteOrange/Black/WhiteBlue/Black/WhiteBlack/Red/GreenWhite/Red/GreenRed/Black/GreenGreen/Black/OrangeOrange/Black/GreenBlue/White/OrangeBlack/White/Orange
35363738394041424344454647484950
NO. OFCOND. COLOR
White/Red/OrangeOrange/White/BlueWhite/Red/BlueBlack/White/GreenWhite/Black/GreenRed/White/GreenGreen/White/BlueOrange/Red/GreenBlue/Red/GreenBlack/White/BlueWhite/Black/BlueRed/White/BlueGreen/Orange/RedOrange/Red/BlueBlue/Red/OrangeBlack/Orange/Red
Color Code Chart 1 - For cables up to and including 12 conductors
123456
NO. OFCOND. COLOR
BlackWhiteRedGreenBrownBlue
789
101112
NO. OFCOND. COLOR
OrangeYellowVioletGrayPinkTan
12
Communication & Control Cable, Multi-Conductor Electronics
Multi-Conductor, UnshieldedUL 2464, UL 2576, NEC Type CM (UL) c(UL), CSA CMG
CATALOGNUMBER
NO. OFCOND.
AWGSIZE
COND.STRAND.
NOM. INSULATIONTHICKNESS
INCHES
C6351†
C6352C6353C6355C6356C6357C6360C6358C2830†
C2831C2404C2420C2421C2422C2412C2423C2424C2433
2
3
4
5
7
9
12
15
2
3
4
5
7
9
12
15
19
25
20
20
20
20
20
20
20
20
18
18
18
18
18
18
18
18
18
18
7/28
7/28
7/28
7/28
7/28
7/28
7/28
7/28
16/30
16/30
16/30
16/30
16/30
16/30
16/30
16/30
16/30
16/30
mm
0.016
0.016
0.016
0.016
0.016
0.016
0.016
0.016
0.015
0.016
0.016
0.016
0.016
0.016
0.016
0.016
0.016
0.016
0.41
0.41
0.41
0.41
0.41
0.41
0.41
0.41
0.41
0.41
0.41
0.41
0.41
0.41
0.41
0.41
0.41
0.41
NOM. JACKETTHICKNESS
INCHES mm
0.025
0.032
0.032
0.032
0.032
0.032
0.032
0.032
0.025
0.032
0.032
0.032
0.032
0.032
0.032
0.032
0.032
0.032
0.64
0.81
0.81
0.81
0.81
0.81
0.81
0.81
0.64
0.81
0.81
0.81
0.81
0.81
0.81
0.81
0.81
0.81
NOMINAL O.D.
NOM.C-C
CAP.*pF/ftINCHES mm
0.192
0.216
0.235
0.254
0.275
0.317
0.354
0.392
0.190
0.236
0.258
0.280
0.309
0.358
0.401
0.445
0.469
0.549
4.88
5.50
5.97
6.46
6.99
8.05
9.00
9.96
5.33
5.99
6.55
7.11
7.85
9.09
10.19
11.30
11.91
13.94
COLORCODE
Black/Red
1
1
1
1
1
2
2
Black/Red
1
1
1
1
1
2
2
2
2
26.0
26.0
26.0
26.0
26.0
26.0
26.0
26.0
28.0
28.0
28.0
28.0
28.0
28.0
28.0
28.0
28.0
28.0
Product Construction:Conductor:• 20 or 18 AWG fully annealed stranded,
tinned copper per ASTM B-33
Insulation:• Premium-grade, coIor-coded PVC per
UL 1007• Color Code: See charts below
Jacket:• PVC, gray• Temperature Range: –20˚C to +80°C
Applications:• Public address systems• Intercoms• Internal telephones• Remote control circuits• Suitable for EIA RS-232 applications• Suggested voltage rating: 300 volts
Compliances:• NEC Article 800 Type CM (UL: 75°C)• UL Style 2464 (UL: 80°C, 300V)• UL Style 2576 (UL: 80˚C, 150V)• CSA CMG (CSA: 60°C)• Designed to meet UL 70,000 BTU Vertical
Tray Flame Test• Passes CSA CMG Flame Test
Packaging:• Please contact Customer Service for
packaging and color options
*Capacitance between conductors†CM (UL) c(UL), CSA CMG Only
Color Code Chart 1 - For cables up to and including 9 conductors
12345
NO. OFCOND. COLOR
BlackWhiteRedGreenBrown
6789
NO. OFCOND. COLOR
BlueOrangeYellowViolet
Color Code Chart 2 Per ICEA - For cables of 12 thru 25 conductors
123456789
NO. OFCOND. COLOR
BlackWhiteRedGreenOrangeBlueWhite/BlackRed/BlackGreen/Black
101112131415161718
NO. OFCOND. COLOR
Orange/BlackBlue/BlackBlack/WhiteRed/WhiteGreen/WhiteBlue/WhiteBlack/RedWhite/RedOrange/Red
19202122232425
NO. OFCOND. COLOR
Blue/RedRed/GreenOrange/GreenBlack/White/RedWhite/Black/RedRed/Black/WhiteGreen/Black/White
13
Electronics Communication & Control Cable, Multi-Conductor
Product Construction:Conductor:• 16 thru 12 AWG fully annealed stranded
tinned copper per ASTM B-33
Insulation:• Premium-grade, coIor-coded PVC• Color Code: See chart below
Jacket:• PVC, gray• Temperature Range: –20°C to + 80°C
Applications:• Public address systems• Intercoms• Internal telephones• Remote control circuits• Suitable for EIA RS-232 applications• Suggested voltage rating: 300 volts
Compliances:• NEC Article 725 Type CL3 (UL: 75°C)• NEC Article 800 Type CM (UL: 75°C)• UL Style 2464 (UL: 80°C, 300V)• UL Style 2587 (UL: 90°C, 600V)• CSA CMG (CSA: 60°C)• Designed to meet UL 70,000 BTU Vertical
Tray Flame Test• Passes CSA CMG Flame Test
Packaging:• Please contact Customer Service for
packaging and color options
Multi-Conductor, UnshieldedUL 2464, UL 2587, NEC Type CL3 and CM (UL) c(UL), CSA CMG
CATALOGNUMBER
NO. OFCOND.
AWGSIZE
COND.STRAND.
NOM. INSULATIONTHICKNESS
INCHES
C2405C2406C2425C2434C2426C2443C2435C2427C2428C2429C2436
2
3
4
5
7
8
9
12
15
19
25
16
16
16
16
16
16
16
16
16
16
16
19/.0117
19/.0117
19/.0117
19/.0117
19/.0117
19/.0117
19/.0117
19/.0117
19/.0117
19/.0117
19/.0117
mm
0.021
0.021
0.021
0.021
0.021
0.021
0.021
0.021
0.021
0.021
0.021
0.53
0.53
0.53
0.53
0 53
0.53
0.53
0 53
0 53
0.53
0.53
NOM. JACKETTHICKNESS
INCHES mm
0.032
0.032
0.032
0.032
0.032
0.032
0.032
0.032
0.032
0.032
0.032
0.81
0.81
0.81
0.81
0.81
0.81
0.81
0.81
0.81
0.81
0.81
NOMINAL O.D.
INCHES mm
0.268
0.283
0.306
0.334
0.363
0.393
0.423
0.476
0.530
0.559
0.657
6.81
7.19
7.77
8.48
9.25
10.03
10.80
12.17
13.46
14.33
16.69
NEC TYPE CM, UL STYLE 2464 (300 volts)
C2409†
C2430C2437C2431C2410C2440
2
4
5
7
2
4
14
14
14
14
12
12
19/.0147
19/.0147
19/.0147
19/.0147
19/0.0185
19/0.0185
0.032
0.032
0.032
0.032
0.032
0.032
0.81
0.81
0.81
0.81
0.81
0.81
0.032
0.032
0.032
0.032
0.032
0.032
0.81
0.81
0.81
0.81
0.81
0.81
0.326
0.391
0.428
0.469
0.366
0.434
8.51
9.93
10.87
11.91
9.40
11.02
NEC TYPE CL3, UL STYLE 2587 (600 volts)
*Capacitance between conductors†CL3, UL2587, CSA CMH Only
Color Code Chart Per ICEA
123456789
NO. OFCOND. COLOR
BlackWhiteRedGreenOrangeBlueWhite/BlackRed/BlackGreen/Black
101112131415161718
NO. OFCOND. COLOR
Orange/BlackBlue/BlackBlack/WhiteRed/WhiteGreen/WhiteBlue/WhiteBlack/RedWhite/RedOrange/Red
19202122232425
NO. OFCOND. COLOR
Blue/RedRed/GreenOrange/GreenBlack/White/RedWhite/Black/RedRed/Black/WhiteGreen/Black/White
NOM.C-C
CAP.*pF/ft
30.5
30.5
30.5
30.5
30.5
30.5
30.5
30.5
30.5
30.5
30.5
29.0
28.2
28.2
28.2
31.5
31.5
14
Communication & Control Cable, Multi-Conductor Electronics
Multi-Conductor, UnshieldedUL 2464, NEC Type CM (UL) c(UL), CSA CMG
C4081
C4082
C4083
C4084
6
7
8
9
4-222-18
5-222-18
6-222-18
7-222-18
7/3016/30
7/3016/30
7/3016/30
7/3016/30
0.0100.016
0.0100.016
0.0100.016
0.0100.016
0.250.41
0.250.41
0.250.41
0.250.41
0.032
0.032
0.032
0.032
0.81
0.81
0.81
0.81
0.244
0.253
0.263
0.273
6.20
6.43
6.69
6.94
25.528.0
25.528.0
25.528.0
25.528.0
Product Construction:Conductor:• 22 thru 18 fully annealed stranded tinned
copper per ASTM B-33
Insulation:• Premium-grade, coIor-coded PVC (18 AWG),
S-R PVC (22 AWG)• Color Code: See chart below
Jacket:• PVC, gray• Temperature Range: –20°C to +80°C
Applications:• TV antenna rotor control• Satellite actuator control• Public address systems• Suggested voltage rating: 300 volts
Features:• Tinned copper conductors provide excellent
corrosion resistance• Assists with soldering applications
Compliances:• NEC Article 800 Type CM (UL: 75°C)• UL Style 2464 (UL: 80°C, 300V)• CSA CMG (CSA: 60°C)• Designed to meet UL 70,000 BTU Vertical
Tray Flame Test• Passes CSA CMG Flame Test
Packaging:• Please contact Customer Service for
packaging and color options
*Capacitance between conductors
CATALOGNUMBER
NO. OFCOND.
AWGSIZE
COND.STRAND.
NOM. INSULATIONTHICKNESS
INCHES mm
NOM. JACKETTHICKNESS
INCHES mm
NOMINAL O.D.
NOM.C-C
CAP.*pF/ftINCHES mm
Color Code Chart
1 18 ga.21 22 ga.234567
NO. OF COND. COLOR
BlackWhiteRedGreenBrownBlueOrangeYellowViolet
15
Electronics Communication & Control Cable, Multi-Conductor
Product Construction:Conductor:• 22 thru 12 AWG fully annealed stranded
tinned copper per ASTM B-33
Insulation:• Premium-grade, coIor-coded PVC• Color Code: See chart below
Jacket:• PVC, gray• Temperature Range: –20˚C to + 105°C
Applications:• Cable tray installations• Power limited circuits• Intercom systems• Business machines• Cash registers• Automatic valve control systems• Irrigation systems• Suggested voltage rating: 300 volts• Burglar alarms
Features:• Sunlight-resistant PVC jacket• UL rated for cable tray use
Compliances:• NEC Article 725 Power-Limited Tray Cable
(UL: 105°C, 300V)• Meets UL 70,000 BTU Vertical Tray
Flame Test
Packaging:• Please contact Customer Service for
packaging and color options
Power-Limited Tray Cable, UnshieldedNEC Type PLTC
C0431C0432C0433C0434C0435C0436C0444C0437C0438C0439C0440C0441
2
3
2
3
2
3
4
2
3
2
3
2
22
22
20
20
18
18
18
16
16
14
14
12
7/30
7/30
7/28
7/28
16/30
16/30
16/30
19/.0117
19/.0117
19/.0147
19/.0147
19/.0185
0.013
0.013
0.013
0.013
0.015
0.015
0.015
0.013
0.013
0.013
0.013
0.013
0.33
0.33
0.33
0.33
0.38
0.38
0.38
0.33
0.33
0.33
0.33
0.33
0.037
0.037
0.037
0.037
0.037
0.037
0.037
0.037
0.037
0.042
0.042
0.042
0.94
0.94
0.94
0.94
0.94
0.94
0.94
0.94
0.94
1.07
1.07
1.07
0.190
0.198
0.206
0.216
0.226
0.237
0.257
0.243
0.250
0.288
0.290
0.315
4.83
5.03
5.23
5.49
5.74
6.02
6.53
6.17
6.35
7.32
7.37
8.00
25.5
25.5
28.0
28.0
28.0
28.0
28.0
34.0
34.0
37.0
37.0
40.0*Capacitance between conductors
CATALOGNUMBER
NO. OFCOND.
AWGSIZE
COND.STRAND.
NOM. INSULATIONTHICKNESS
INCHES mm
NOM. JACKETTHICKNESS
INCHES mm
NOMINAL O.D.
NOM.C-C
CAP.*pF/ftINCHES mm
Color Code Chart
1234
NO. OF COND. COLOR
BlackRedWhiteGreen
16
Communication & Control Cable, Multi-Conductor Electronics
Multi-Conductor, Rubber, Unshielded
CATALOGNUMBER
NO. OFCOND.
AWGSIZE
COND.STRAND.
NOM. INSULATIONTHICKNESS
NOM. JACKETTHICKNESS NOMINAL O.D.
INCHES mm INCHES mm INCHES mm
C3602C3603C3604C3605C3606C3607C3608C3610
2
3
4
5
6
7
8
10
20
20
20
20
20
20
20
20
26/34
26/34
26/34
26/34
26/34
26/34
26/34
26/34
0.020
0.020
0.020
0.020
0.020
0.020
0.020
0.020
0.51
0.51
0.51
0.51
0.51
0.51
0.51
0.51
0.035
0.035
0.035
0.035
0.035
0.035
0.035
0.035
0.89
0.89
0.89
0.89
0.89
0.89
0.89
0.89
0.230
0.255
0.260
0.300
0.315
0.347
0.360
0.410
5.84
6.48
6.60
7.62
8.00
8.81
9.14
10.41
Product Construction:Conductor:• 20 AWG fully annealed stranded tinned
copper per ASTM B-33
Insulation:• Premium-grade, coIor-coded rubber• Color Code: See chart below
Jacket:• Rubber, black• Temperature Range: –20˚C to +60˚C
Applications:• Energy management systems• Control circuits• Fire alarm control• Broadcast and studio requirements• Suggested voltage rating: 350 volts
Features:• Excellent impact resistance• High level of abrasion resistance• High flexibility• Excellent mechanical strength• Excellent moisture resistance
Compliances:• RoHS Compliant Directive 2002/95/EC
Packaging:• Please contact Customer Service for
packaging and color options
Color Code Chart
123456789
10
NO. OF COND. COLOR
BlackWhiteRedGreenBlueBrownYellowOrangeGrayViolet
UL STYLE 2107, CM (UL) c(UL) CMH, 600V
* CM (UL) c(UL) CMH** CL2Polyethylene Insulation, Color Code Chart #1
CM (UL) c(UL) CMH, 300V
UL STYLE 2464, CL2/CM (UL) c(UL) CMH, 300V
Polyethylene Insulation, Color Code Chart #1
Polyethylene Insulation, Color Code Chart #1
UL STYLE 2094, CM (UL) c(UL) CMH, 300V
UL STYLE 2106, CSA, 600V
UL STYLE 2093, CM (UL) c(UL) CMH, 300VPolyethylene Insulation, Color Code Chart #1
UL STYLE 2092, CM (UL) c(UL) CMH, 300V
17
Electronics Communication & Control Cable, Multi-Conductor
C2537
Product Construction:Conductor:• 24 thru 12 AWG fully annealed solid or
stranded tinned copper per ASTM B-33
Insulation:• Premium-grade, coIor-coded polyethylene• Premium-grade, coIor-coded polypropylene• Color Code: See charts below
Shield:• 100% Flexfoil® aluminum/polyester,
25% overlap, foil facing out• Stranded tinned copper drain wire
Jacket:• PVC, gray• Temperature Range: –20°C to + 75°C
Applications:• Recording studios and sound stages• Broadcast and sound systems• Computers• Industrial equipment control• Suggested voltage rating: 300 or 600 volts
Features:• Excellent electrical properties• Superior shielding effectiveness • 25% shield overlap provides excellent
shielding efficiency• Good flexibility
Compliances:• UL Style 2092 (UL: 60°C, 300V)• UL Style 2093 (UL: 60°C, 300V)• UL Style 2094 (UL: 60°C, 300V)• UL Style 2106 (UL: 60°C, 600V)• UL Style 2107 (UL: 60°C, 600V)• UL Style 2464 (UL: 80°C, 300V)• NEC Article 725 Type CL2 (UL: 75°C)• NEC Article 800 Type CM (UL: 75°C)• Designed to meet UL 70,000 BTU Vertical
Tray Flame Test• CSA CMH (CSA: 60˚C)• Passes CSA CMH Flame Test
Packaging:• Please contact Customer Service for
packaging and color options
Multi-Conductor, Foil ShieldNEC Type CL2 and CM (UL) c(UL) CMH
CATALOGNUMBER
NO. OFCOND.
AWGSIZE
COND.STRAND.
NOM. INSULATIONTHICKNESS
NOM. JACKETTHICKNESS NOMINAL O.D.
NOM. CAP.***pF/ft
INCHES mm INCHES mm INCHES mm A B
C2513C2514C2524C2534
2
2
2
2
24
22
20
18
7/32
7/30
7/28
16/30
0.016
0.016
0.016
0.016
0.41
0.41
0.41
0.41
0.026
0.020
0.020
0.020
0.66
0.51
0.51
0.51
0.167
0.167
0.183
0.205
4.24
4.24
4.65
5.21
19.0
21.0
23.0
26.0
34.0
37.0
41.0
47.0
C2526C2528C2525C2535
3
3
3
3
22
20
20
18
7/30
7/28
7/28
16/30
0.016
0.016
0.016
0.016
0.41
0.41
0.41
0.41
0.030
0.030
0.030
0.020
0.76
0.76
0.76
0.51
0.196
0.210
0.213
0.219
4.98
5.34
5.41
5.56
19.0
21.0
21.0
23.0
34.0
38.0
37.0
42.0
Polyethylene Insulation, Color Code Chart #1
PVC Insulation, Color Code Chart #2
Polypropylene Insulation, Color Code Chart #2***A - Capacitance between conductors***B - Capacitance between one conductor and other conductors connected to shield
C2523C2555
4
4
22
20
7/30
7/28
0.016
0.016
0.41
0.41
0.030
0.030
0.76
0.76
0.213
0.234
5.41
5.94
19.0
21.0
34.0
38.0
C2536*C2538**C2539**
2
2
2
16
14
12
19/.0117
19/.0147
19/.0185
0.031
0.031
0.032
0.79
0.79
0.81
0.032
0.032
0.032
0.81
0.81
0.81
0.307
0.335
0.376
7.80
8.51
9.55
20.0
23.0
26.0
36.0
42.0
47.0
C2515C2516C2517
2
2
3
22
22
22
Solid
7/30
7/30
0.007
0.008
0.008
0.18
0.20
0.20
0.020
0.020
0.020
0.51
0.51
0.51
0.124
0.137
0.144
3.15
3.48
3.66
30.0
28.0
25.0
55.0
51.0
46.0
3 16 19/.0117 0.031 0.79 0.032 0.81 0.325 8.26 19.0 34.0
C2540 2 20 7/28 .013 0.33 .032 0.81 .194 4.9 49.7 89.5
Color Code Chart 1
1234
NO. OF COND. COLOR
BlackNaturalRedGreen
Color Code Chart 2
123
NO. OF COND. COLOR
BlackRedClear
18
Communication & Control Cable, Multi-Conductor Electronics
Multi-Conductor, Foil ShieldUL 2464, NEC Type CM (UL) c(UL), CSA CMG
Product Construction:Conductor:• 18 AWG fully annealed stranded tinned
copper per ASTM B-33
Insulation:• Premium-grade, coIor-coded S-R PVC• Color Code: See chart below
Shield:• 100% Flexfoil® aluminum/polyester,
25% overlap, foil facing out• Stranded tinned copper drain wire
Jacket:• PVC, gray• Temperature Range: –20°C to +80°C
Applications:• Audio, broadcast, instrumentation and
sound systems• Suggested voltage rating: 300 volts
Compliances:• NEC Article 800 Type CM (UL: 75˚C)• UL Style 2464 (UL: 80˚C, 300V)• CSA CMG (60°C)• Designed to meet UL 70,000 BTU Vertical
Tray Flame Test• Passes CSA CMG Flame Test
Packaging:• Please contact Customer Service for
packaging and color options
C2543 4 18 19/30 0.010 0.25 0.032 0.81 0.238 6.05 48 87*A - Capacitance between conductors*B - Capacitance between one conductor and other conductors connected to shield
Color Code Chart
1234
NO. OF COND. COLOR
BlackRedWhiteGreen
CATALOGNUMBER
NO. OFCOND.
AWGSIZE
COND.STRAND.
NOM. INSULATIONTHICKNESS
NOM. JACKETTHICKNESS NOMINAL O.D.
NOM. CAP.*pF/ft
INCHES mm INCHES mm INCHES mm A B
UL STYLE 2092, CM (UL) c(UL) CMH, 300V
Polyethylene Insulation, Color Code Chart #1
19
Electronics Communication & Control Cable, Multi-Conductor
Product Construction:Conductor:• 22 thru 18 AWG fully annealed stranded
tinned copper per ASTM B-33
Insulation:• Premium-grade, coIor-coded polypropylene
or polyethylene• Color Code: See charts below
Shield:• 100% aluminum/polyester foil “bonded”
to jacket, foil facing in• Stranded tinned copper drain wire
Jacket:• PVC, gray• Temperature Range: –20°C to + 75°C
Applications:• 100% shielded cable where RF shielding
is required• Control circuits• Data and signal transmission• Computer interconnections• Suggested voltage rating: 300 volts
Features:• The jacket and shield are “bonded” for
ease of removal on automatic strippingequipment
Compliances:• NEC Article 800 Type CM (UL: 75°C)• UL Style 2092 (UL: 60°C, 300V)• Designed to meet UL 70,000 BTU Vertical
Tray Flame Test• CSA CMH (CSA: 60˚C)• Passes CSA CMH Flame Test
Packaging:• Please contact Customer Service for
packaging and color options
Multi-Conductor, Foil ShieldUL 2092, NEC Type CM (UL) c(UL) CMH
C2518C2519C2521
2
2
2
22
20
18
7/30
7/28
16/30
0.016
0.016
0.018
0.41
0.41
0.46
0.026
0.028
0.028
0.66
0.71
0.71
0.181
0.201
0.229
4.60
5.11
5.82
20.0
22.0
24.3
36.0
40.0
44.8
Polypropylene Insulation, Color Code Chart #2*A - Capacitance between conductors*B - Capacitance between one conductor and other conductors connected to shield
C2520 2 22 7/30 0.008 0.20 0.020 0.51 0.137 3.48 28.3 44.6
CM (UL) c(UL) CMH, 300V
Color Code Chart 1
12
NO. OF COND. COLOR
BlackNatural
Color Code Chart 2
12
NO. OF COND. COLOR
BlackRed
CATALOGNUMBER
NO. OFCOND.
AWGSIZE
COND.STRAND.
NOM. INSULATIONTHICKNESS
NOM. JACKETTHICKNESS NOMINAL O.D.
NOM. CAP.*pF/ft
INCHES mm INCHES mm INCHES mm A B
20
Communication & Control Cable, Multi-Conductor Electronics
Power-Limited Tray Cable, Foil ShieldNEC Type PLTC
Product Construction:Conductor:• 22 thru 12 AWG fully annealed stranded
tinned copper per ASTM B-33
Insulation:• Premium-grade, coIor-coded PVC• Color Code: See chart below
Shield:• 100% Flexfoil® aluminum/polyester,
25% overlap foil facing out• Stranded tinned copper drain wire
Jacket:• PVC, gray• Temperature Range: –20°C to +105˚C
Applications:• Cable tray installations• Power limited circuits• Intercom systems• Business machines• Cash registers• Industrial control systems• Petrochemical refineries• Suggested voltage rating: 300 volts• Burglar Alarms
Features:• Sunlight-resistant PVC jacket• Good weather resistance• UL tray cable rated
Compliances:• NEC Article 725 Power-Limited Tray Cable
(UL: 105°C, 300V)• Designed to meet UL 70,000 BTU Vertical
Tray Flame Test
Packaging:• Please contact Customer Service for
packaging and color options
C0450C0451C0452C0453C0454C0455C0456C0457C0458C0459C0460
2
3
2
3
2
3
2
3
2
3
2
22
22
20
20
18
18
16
16
14
14
12
7/30
7/30
7/28
7/28
16/30
16/30
19/.0117
19/.0117
19/.0147
19/.0147
19/.0185
0.013
0.013
0.013
0.013
0.015
0.015
0.013
0.013
0.013
0.013
0.013
0.33
0.33
0.33
0.33
0.38
0.38
0.33
0.33
0.33
0.33
0.33
0.037
0.037
0.037
0.037
0.037
0.037
0.037
0.037
0.042
0.042
0.042
0.94
0.94
0.94
0.94
0.94
0.94
0.94
0.94
1.07
1.07
1.07
0.191
0.199
0.207
0.217
0.227
0.238
0.243
0.255
0.288
0.298
0.315
4.85
5.05
5.26
5.51
5.77
6.04
6.17
6.48
7.32
7.57
8.00
39.0
36.0
44.0
40.0
46.0
41.0
57.0
50.0
66.0
57.0
71.0
70.0
64.0
80.0
72.0
82.0
74.0
103.0
90.0
119.0
103.0
129.0*A - Capacitance between conductors*B - Capacitance between one conductor and other conductors connected to shield
Color Code Chart
123
NO. OF COND. COLOR
BlackRedWhite
CATALOGNUMBER
NO. OFCOND.
AWGSIZE
COND.STRAND.
NOM. INSULATIONTHICKNESS
NOM. JACKETTHICKNESS NOMINAL O.D.
NOM. CAP.*pF/ft
INCHES mm INCHES mm INCHES mm A B
UL STYLE 2095, CM (UL) c(UL), CSA CMG, 300V
21
Electronics Communication & Control Cable, Multi-Conductor
Color Code Chart #1
C2882C2888
2
2
22
20
7/30
7/28
0.015
0.016
0.38
0.41
0.032
0.032
0.81
0.81
0.197
0.215
5.00
5.46
41.0
44.0
73.0
80.2Color Code Chart #1
Product Construction:Conductor:• 22 thru 16 AWG fully annealed stranded
tinned copper per ASTM B-33
Insulation:• Premium-grade, coIor-coded PVC• Color Code: See charts below
Shield:• 85% spiral tinned copper
Jacket:• PVC, gray• Temperature Range: –20°C to + 80°C
Applications:• Electronic circuits where RF shielding
is required• Radio transmitters• Sound systems• Recording studios• Suggested voltage rating: 300 volts
Features:• Spiral shield allows ease of “pigtail
soldering”• Maximum flexibility
Compliances:• NEC Article 800 Type CM (UL: 75°C)• UL Style 2095 (UL: 80°C, 300V)• CSA CMG (CSA: 60°C)• Designed to meet UL 70,000 BTU Vertical
Tray Flame Test• Passes CSA CMG Flame Test• NEC Article 725 Type CL2 (UL: 75°C)
Packaging:• Please contact Customer Service for
packaging and color options
Multi-Conductor, Spiral ShieldUL 2095, NEC Type CL2 and CM (UL) c(UL), CSA CMG
CM (UL) c(UL), CSA CMG, 300VC2892C2895
2
2
18
16
16/30
19/.0117
0.016
0.016
0.41
0.41
0.032
0.032
0.81
0.81
0.252
0.265
6.40
6.73
50.4
58.0
90.8
104.0
CL2/CM (UL) c(UL), CSA CMG, 300VC1335C1337C1341C2768
3
4
6
3
22
22
22
18
7/30
7/30
7/30
7/26
0.015
0.015
0.015
0.020
0.38
0.38
0.38
0.51
0.032
0.032
0.032
0.032
0.81
0.81
0.81
0.81
0.206
0.222
0.257
0.266
5.23
5.64
6.53
6.76
37.0
37.0
40.6
41.0
67.0
67.0
73.1
74.0
Color Code Chart #2*A - Capacitance between conductors*B - Capacitance between one conductor and other conductors connected to shield
Color Code Chart 1
123456
NO. OF COND. COLOR
BlackRedWhiteGreenYellowBlue
Color Code Chart 2
C2892
C2895
CATALOGNUMBER CONDUCTOR COLOR
1212
WhiteRedWhiteBlack
CATALOGNUMBER
NO. OFCOND.
AWGSIZE
COND.STRAND.
NOM. INSULATIONTHICKNESS
NOM. JACKETTHICKNESS NOMINAL O.D.
NOM. CAP.*pF/ft
INCHES mm INCHES mm INCHES mm A B
22
Communication & Control Cable, Multi-Conductor Electronics
Multi-Conductor, Braid ShieldNEC Type CL2 and CM(UL) c(UL), CSA CMG
Product Construction:Conductor:• 22 AWG fully annealed solid or stranded
tinned copper per ASTM B-33
Insulation:• Premium-grade, coIor-coded PVC• Color Code: See chart below
Shield:• 88% tinned copper braid• Stranded or solid tinned copper drain wire
Jacket:• PVC, black• Temperature Range: –20°C to +75°C
Applications:• Electronic circuits where RF shielding
is required• Radio transmitters• Sound systems• Recording studios• Good flexibility• Excellent shielding for noise reduction• Suggested voltage rating: 300 volts
Compliances:• NEC Article 800 Type CM (UL: 75°C)• Designed to meet UL 70,000 BTU Vertical
Tray Flame Test• CSA CMG (CSA: 60°C)• Passes CSA CMG Flame Test• NEC Article 725 Type CL2 (UL: 75°C)
Packaging:• Please contact Customer Service for
packaging and color options
C2676C2677
2
2
22
22
Solid
7/30
0.015
0.015
0.38
0.38
0.032
0.032
0.81
0.81
0.209
0.211
5.31
5.36
38.6 69.4
39.3 70.7*A - Capacitance between conductors*B - Capacitance between one conductor and other conductors connected to shield
Color Code Chart
12
NO. OF COND. COLOR
BlackRed
CATALOGNUMBER
NO. OFCOND.
AWGSIZE
COND.STRAND.
NOM. INSULATIONTHICKNESS
NOM. JACKETTHICKNESS NOMINAL O.D.
INCHES mm INCHES mm INCHES mm
NOM. CAP.*pF/ft
A B
23
Electronics Communication & Control Cable, Multi-Conductor
Product Construction:Conductor:• 22 thru 18 AWG fully annealed stranded
tinned copper per ASTM B-33
Insulation:• Premium-grade, coIor-coded PVC• Color Code: See chart below
Shield:• 75% tinned copper braid
Jacket:• PVC, gray• Temperature Range: –20°C to + 80°C
Applications:• Electronic circuits where RF shielding
is required• Radio transmitters• Sound systems• Recording studios• Provides good flexibility• Excellent shielding for noise reduction• Suggested voltage rating: 300 volts
Compliances:• NEC Article 800 Type CM (UL: 75°C)• UL Style 2095 (UL: 80°C, 300V)• Designed to meet UL 70,000 BTU Vertical
Tray Flame Test• CSA CMG (CSA: 60°C)• Passes CSA CMG Flame Test
Packaging:• Please contact Customer Service for
packaging and color options
Multi-Conductor, Braid ShieldUL 2095, NEC Type CM (UL) c(UL), CSA CMG
C2679C2678C2680C2681C1332C2683C2686C2687C2688C2689
2
3
4
2
3
4
2
3
4
2
22
22
22
20
20
20
18
18
18
16
7/30
7/30
7/30
7/28
7/28
7/28
16/30
16/30
16/30
19/29
0.015
0.015
0.015
0.016
0.016
0.016
0.016
0.016
0.016
0.020
0.38
0.38
0.38
0.41
0.41
0.41
0.41
0.41
0.41
0.51
0.032
0.032
0.032
0.032
0.032
0.032
0.032
0.032
0.032
0.030
0.81
0.81
0.81
0.81
0.81
0.81
0.81
0.81
0.81
0.76
0.212
0.221
0.237
0.230
0.240
0.259
0.252
0.264
0.286
0.280
5.38
5.61
6.02
5.84
6.10
6.58
6.40
6.71
7.26
7.11
41.0
37.0
37.0
44.0
40.0
40.0
50.0
46.0
46.0
51.0
73.0
67.0
67.0
80.0
72.0
73.0
91.0
82.0
82.0
91.0*A - Capacitance between conductors*B - Capacitance between one conductor and other conductors connected to shield
Color Code Chart
1234
NO. OF COND. COLOR
BlackRedWhiteGreen
CATALOGNUMBER
NO. OFCOND.
AWGSIZE
COND.STRAND.
NOM. INSULATIONTHICKNESS
NOM. JACKETTHICKNESS NOMINAL O.D.
NOM. CAP.*pF/ft
INCHES mm INCHES mm INCHES mm A B
24
Communication & Control Cable, Multi-Conductor Electronics
Multi-Conductor, Braid ShieldMIL-W-16878 Type B
Product Construction:Conductor:• 28 AWG fully annealed stranded tinned
copper per ASTM B-33
Insulation:• Premium-grade, coIor-coded PVC per
MIL-W-16878 Type B• Color Code: See chart below
Shield:• 90% tinned copper braid
Jacket:• PVC, gray• Temperature Range: –20°C to +90°C
Applications:• Electronic circuits where RF shielding
is required• Remote control for studio equipment• Sound systems• Provides good flexibility• Excellent shielding for noise reduction• Suggested voltage rating: 600 volts• Non QPL
Packaging:• Please contact Customer Service for
packaging and color options
C6500C6501C6502C6503C6504C6505C6506C6507C6508
2
3
4
6
8
10
12
15
20
28
28
28
28
28
28
28
28
28
7/36
7/36
7/36
7/36
7/36
7/36
7/36
7/36
7/36
0.010
0.010
0.010
0.010
0.010
0.010
0.010
0.010
0.010
0.28
0.28
0.28
0.28
0.28
0.28
0.28
0.28
0.28
0.016
0.016
0.016
0.019
0.021
0.021
0.021
0.021
0.021
0.41
0.41
0.41
0.48
0.53
0.53
0.53
0.53
0.53
0.130
0.135
0.145
0.172
0.187
0.212
0.217
0.239
0.289
3.30
3.30
3.68
4.37
4.75
5.38
5.51
6.02
7.34
30.0
28.0
28.0
27.0
27.0
27.0
27.0
27.0
27.0
54.0
51.0
51.0
48.0
48.0
48.0
48.0
48.0
48.0 *A - Capacitance between conductors*B - Capacitance between one conductor and other conductors connected to shield
Color Code Chart
1234567
NO. OFCOND. COLOR
BlackWhiteRedGreenOrangeBlueWhite/Black
89
1011121314
NO. OFCOND. COLOR
NO. OFCOND. COLOR
Red/BlackGreen/BlackOrange/BlackBlue/BlackBlack/WhiteRed/WhiteGreen/White
151617181920
Blue/WhiteBlack/RedWhite/RedOrange/RedBlue/RedRed/Green
CATALOGNUMBER
NO. OFCOND.
AWGSIZE
COND.STRAND.
NOM. INSULATIONTHICKNESS
NOM. JACKETTHICKNESS NOMINAL O.D.
NOM. CAP.*pF/ft
INCHES mm INCHES mm INCHES mm A B
AWM STYLE 2092, CM (UL) c(UL) CMH, 300V
AWM STYLE 2093, CM (UL) c(UL) CMH, 300V
AWM STYLE 2094, CM (UL) c(UL) CMH, 300V
25
Electronics Communication & Control Cable, Multi-Conductor
Product Construction:Conductor:• 20 AWG fully annealed stranded tinned
copper per ASTM B-33
Insulation:• Premium-grade, coIor-coded polyethylene• Color Code: See chart below
Shield:• 80% tinned copper braid • Mylar wrap under braid
Jacket:• PVC, gray• Temperature Range: –20°C to + 75°C
Applications:• Electronic circuits where RF shielding
is required• Video interconnect• Broadcast and studio• Sound systems• Suggested voltage rating: 300 volts
Features:• Low capacitance• Lightweight• Excellent shielding for noise reduction
Compliances:• NEC Article 800 Type CM (UL: 75°C)• AWM style 2092 (UL: 60˚C, 300V)• AWM style 2093 (UL: 60˚C, 300V)• AWM style 2094 (UL: 60˚C, 300V)• Designed to meet UL VW-1 Vertical Wire
Flame Test
Packaging:• Please contact Customer Service for
packaging and color options
Multi-Conductor, Braid ShieldUL 2092, 2093, 2094
C1644C1645C1646
4
5
6
20
20
20
26/34
26/34
26/34
0.016
0.016
0.016
0.38
0.38
0.38
0.029
0.029
0.029
0.74
0.74
0.74
0.255
0.274
0.294
6.48
6.96
7.47
22.0
22.0
19.4
37.6
37.6
37.0
*A - Capacitance between conductors*B - Capacitance between one conductor and other conductors connected to shield
Color Code Chart
123456
NO. OF COND. COLOR
BlackWhiteRedGreenYellowBlue
CATALOGNUMBER
NO. OFCOND.
AWGSIZE
COND.STRAND.
NOM. INSULATIONTHICKNESS
NOM. JACKETTHICKNESS NOMINAL O.D.
NOM. CAP.* pF/ft
INCHES mm INCHES mm INCHES mm A B
C1642 2 20 26/34 0.016 0.38 0.029 0.74 0.226 5.74 24.0 41.0
C1643 3 20 26/34 0.016 0.38 0.029 0.74 0.236 5.99 22.0 40.0
26
Communication & Control Cable, Multi-Conductor Electronics
Multi-Conductor, Foil/Braid ShieldUL 2094, NEC Type CL2
Product Construction:Conductor:• 20 AWG fully annealed stranded tinned
copper per ASTM B-33
Insulation:• Premium-grade, coIor-coded polyethylene• Color Code: See chart below
Shield:• 100% Flexfoil® aluminum/polyester,
25% overlap, foil facing out • 80% tinned copper braid
Jacket:• PVC, gray• Temperature Range: –20°C to +75°C
Applications:• Electronic circuits where RF shielding
is required• Video interconnect• Broadcast and studio• Sound systems• Suggested voltage rating: 300 volts
Features:• Low capacitance• Lightweight• Excellent shielding for noise reduction
Compliances:• NEC Article 725 Type CL2 (UL: 75°C)• UL Style 2094 (UL: 60°C, 300V)• Designed to meet UL 70,000 BTU Vertical
Tray Flame Test
Packaging:• Please contact Customer Service for
packaging and color options
C1648 8 20 26/34 0.016 0.38 0.029 0.74 0.316 8.03 20.0 36.0*A - Capacitance between conductors*B - Capacitance between one conductor and other conductors connected to shield
1234
BlackWhiteRedGreen
5678
YellowBlueBrownOrange
Color Code Chart NO. OF COND. COLOR
NO. OF COND. COLOR
CATALOGNUMBER
NO. OFCOND.
AWGSIZE
COND.STRAND.
NOM. INSULATIONTHICKNESS
NOM. JACKETTHICKNESS NOMINAL O.D.
NOM. CAP.*pF/ft
INCHES mm INCHES mm INCHES mm A B
27
Electronics Communication & Control Cable, Multi-Conductor
Product Construction:Conductor:• 20 AWG fully annealed stranded tinned
copper per ASTM B-33
Insulation:• Premium-grade, coIor-coded rubber• Color Code: See chart below
Shield:• 80% tinned copper braid
Jacket:• Rubber, black• Temperature Range: –20°C to + 60°C
Applications:• Control circuits• Broadcast and studio applications• Audio interconnects• Suggested voltage rating: 300 volts
Features:• Impact- and abrasion-resistant• Stranded conductors for superior flexibility
Compliances:• RoHS Compliant Directive 2002/95/EC
Packaging:• Please contact Customer Service for
packaging and color options
Multi-Conductor, Rubber, Braid Shield
C1302C1304C1305C1308C1310C1312C1313
2
3
4
5
6
7
8
20
20
20
20
20
20
20
26/34
26/34
26/34
26/34
26/34
26/34
26/34
0.020
0.020
0.020
0.020
0.020
0.020
0.020
0.51
0.51
0.51
0.51
0.51
0.51
0.51
0.035
0.035
0.035
0.035
0.035
0.035
0.035
0.89
0.89
0.89
0.89
0.89
0.89
0.89
0.270
0.285
0.300
0.330
0.340
0.355
0.385
6.86
7.24
7.62
8.38
8.64
9.02
9.78
1234
BlackWhiteRedGreen
5678
BlueBrownYellowOrange
Color Code Chart NO. OF COND. COLOR
NO. OF COND. COLOR
CATALOGNUMBER
NO. OFCOND.
AWGSIZE
COND.STRAND.
NOM. INSULATIONTHICKNESS
NOM. JACKETTHICKNESS NOMINAL O.D.
INCHES mm INCHES mm INCHES mm
28
Communication & Control Cable, Multi-Conductor Electronics
Multi-Conductor, Carolprene®, Braid Shield
Product Construction:Conductor:• 18 thru 14 AWG fully annealed stranded
tinned copper per ASTM B-33
Insulation:• Premium-grade, coIor-coded rubber• Color Code: See chart below
Shield:• 80% tinned copper braid
Jacket:• Carolprene®, black• Temperature Range: –20°C to +60°C
Applications:• Control circuits• Broadcast and studio applications• Audio interconnects• Suggested voltage rating: 300 volts
Features:• Impact- and abrasion-resistant• Stranded conductors for superior flexibility• Designed to Meet UL VW-1 Vertical Wire
Flame Test
Compliance:• RoHS Compliant Directive 2002/95/EC
Packaging:• Please contact Customer Service for
packaging and color options
C1202C1203C1204C1206C1208C1210C1212C1602C1603C1604C1606C1608C1612C1614
2
3
4
6
8
10
12
2
3
4
6
8
2
4
18
18
18
18
18
18
18
16
16
16
16
16
14
14
41/34
41/34
41/34
41/34
41/34
41/34
41/34
65/34
65/34
65/34
65/34
65/34
41/30
41/30
0.020
0.020
0.020
0.020
0.020
0.020
0.020
0.025
0.025
0.025
0.025
0.025
0.030
0.030
0.51
0.51
0.51
0.51
0.51
0.51
0.51
0.64
0.64
0.64
0.64
0.64
0.76
0.76
0.035
0.035
0.035
0.035
0.035
0.035
0.065
0.035
0.035
0.035
0.040
0.040
0.040
0.040
0.89
0.89
0.89
0.89
0.89
0.89
1.65
0.89
0.89
0.89
1.02
1.02
1.02
1.02
0.295
0.305
0.330
0.370
0.420
0.425
0.555
0.335
0.355
0.385
0.445
0.510
0.395
0.455
7.49
7.75
8.38
9.39
10.67
10.80
14.10
8.51
9.02
9.78
11.30
12.95
10.03
11.56
123456
BlackWhiteRedGreenBlueBrown
789
101112
YellowOrangeGrayVioletWhite/BlackWhite/Red
Color Code Chart NO. OF COND. COLOR
NO. OF COND. COLOR
CATALOGNUMBER
NO. OFCOND.
AWGSIZE
COND.STRAND.
NOM. INSULATIONTHICKNESS
NOM. JACKETTHICKNESS NOMINAL O.D.
INCHES mm INCHES mm INCHES mm
Electronics
Communication & Control Cable, Multi-Paired 3
Index Page
Multi-Paired,Unshielded 30-31
Multi-Paired,Foil Shield 32-33
Power-Limited TrayCable, Foil Shield 34
Multi-Paired,Individually Shielded 35-36
Power-Limited TrayCable, IndividuallyShielded 37
In many electronicapplications, two wires arerequired to complete circuits;these are often referred to as“balanced arrays” or “twistedpair” constructions.
Paired cable designs findfrequent application in circuitsrequiring circuit-to-circuitisolation from noise,minimization of capacitanceimbalances and a reduction ofEMI interference currents.
Circuit separation is furtherenhanced in those designsemploying individual circuitshields in concert with anoverall shield. These shieldingsystems are available fromGeneral Cable in myriadcombinations to suit the uniqueneeds of the circuit designer.
As with the multi-conductordesigns, a wide array ofinsulating and jacketingmaterials are available to meetspecific electronic applications.
General Cable’s Carol® Brandcommunication cable productsare manufactured to meet thelatest UL, CSA and NECrequirements and approvals.
29
NEC TYPE CM
Communication & Control Cable, Multi-Paired Electronics
30
Multi-Paired, UnshieldedUL 2464, NEC Type CM (UL) c(UL), CSA CMG
CATALOGNUMBER
NO. OFPAIRS
AWGSIZE
COND.STRAND.
NOM. INSULATIONTHICKNESS
INCHES
C4008C4010C4014C4015C4017C6010C6014C6015C6017C6019C6023C6026
1
2
3
4
6
2
3
4
6
9
12
15
22
22
22
22
22
22
22
22
22
22
22
22
Solid
Solid
Solid
Solid
Solid
7/30
7/30
7/30
7/30
7/30
7/30
7/30
mm
0.010
0.010
0.010
0.010
0.012
0.010
0.010
0.010
0.010
0.010
0.010
0.010
0.25
0.25
0.25
0.25
0.30
0.25
0.25
0.25
0.25
0.25
0.25
0.25
NOM. JACKETTHICKNESS
INCHES mm
0.032
0.032
0.032
0.032
0.032
0.032
0.032
0.032
0.032
0.032
0.032
0.032
0.81
0.81
0.81
0.81
0.81
0.81
0.81
0.81
0.81
0.81
0.81
0.81
NOMINAL O.D.NOMC-CpF/ftINCHES mm
0.156
0.218
0.229
0.249
0.293
0.228
0.240
0.262
0.300
0.366
0.410
0.456
3.94
5.54
5.82
6.32
7.44
5.79
6.10
6.65
7.62
9.30
10.40
11.58
24.5
24.5
24.5
24.5
22.4
27.0
27.0
27.0
27.0
27.0
27.0
25.5
Product Construction:Conductor:• 22 AWG fully annealed solid or stranded
tinned copper per ASTM B-33• Twisted pairs
Insulation:• Premium-grade, coIor-coded S-R PVC• Color Code: See chart below
Jacket:• PVC, gray• Temperature Range: –20˚C to +80˚C
Applications:• Computers• Industrial equipment• Data transmission• Control circuits• Suitable for EIA RS-232 applications• Suggested voltage rating: 300 volts
Compliances:• NEC Article 800 Type CM (UL: 75˚C)• UL Style 2464 (UL: 80˚C, 300V)• CSA CMG (CSA: 60˚C)• Designed to meet UL 70,000 BTU Vertical
Tray Flame Test• Passes CSA CMG Flame Test
Packaging:• Please contact Customer Service for
packaging and color options
*Capacitance between conductors
Color Code Chart
12345678
NO. OFPAIRS COLOR
Black paired with RedBlack paired with WhiteBlack paired with GreenBlack paired with BlueBlack paired with YellowBlack paired with BrownBlack paired with OrangeRed paired with White
NO. OFPAIRS COLOR
9101112131415
Red paired with GreenRed paired with BlueRed paired with YellowRed paired with BrownRed paired with OrangeGreen paired with WhiteGreen paired with Blue
Electronics Communication & Control Cable, Multi-Paired
31
Product Construction:Conductor:• 18 AWG fully annealed stranded tinned
copper per ASTM B-33• Twisted pairs
Insulation:• Premium-grade, coIor-coded S-R PVC• Color Code: See chart below
Jacket:• PVC, gray• Temperature Range: –20˚C to + 80˚C
Applications:• Computers• Industrial equipment• Data transmission• Control circuits• Suitable for EIA RS-232 applications• Suggested voltage rating: 300 volts
Compliances:• NEC Article 800 Type CM (UL: 75˚C)• UL Style 2464 (UL: 80˚C, 300V)• CSA CMG (CSA: 60˚C)• Designed to meet UL 70,000 BTU Vertical
Tray Flame Test• Passes CSA CMG Flame Test
Packaging:• Please contact Customer Service for
packaging and color options
Multi-Paired, UnshieldedUL 2464, NEC Type CM (UL) c(UL), CSA CMG
CATALOGNUMBER
NO. OFPAIRS
AWGSIZE
COND.STRAND.
NOM. INSULATIONTHICKNESS
INCHES
C6101C6118C6103C6119C6120C6106C6121C6109C6111
1
2
3
4
5
6
8
9
15
18
18
18
18
18
18
18
18
18
16/30
16/30
16/30
16/30
16/30
16/30
16/30
16/30
16/30
mm
0.013
0.013
0.013
0.013
0.013
0.013
0.013
0.013
0.013
0.33
0.33
0.33
0.33
0.33
0.33
0.33
0.33
0.33
NOM. JACKETTHICKNESS
INCHES mm
0.032
0.032
0.032
0.032
0.032
0.032
0.032
0.032
0.032
0.81
0.81
0.81
0.81
0.81
0.81
0.81
0.81
0.81
NOMINAL O.D.
INCHES mm
0.206
0.320
0.338
0.372
0.408
0.445
0.484
0.522
0.659
5.23
8.13
8.59
9.45
10.36
11.30
12.29
13.26
16.74
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
*Capacitance between conductors
NOMC-CpF/ft
Color Code Chart
12345678
NO. OFPAIRS COLOR
Black paired with RedBlack paired with WhiteBlack paired with GreenBlack paired with BlueBlack paired with YellowBlack paired with BrownBlack paired with OrangeRed paired with White
NO. OFPAIRS COLOR
9101112131415
Red paired with GreenRed paired with BlueRed paired with YellowRed paired with BrownRed paired with OrangeGreen paired with WhiteGreen paired with Blue
Communication & Control Cable, Multi-Paired Electronics
32
Multi-Paired, Foil ShieldUL 2464, UL 2576, NEC Type CM (UL) c(UL), CSA CMG
Product Construction:Conductor:• 22 AWG fully annealed solid tinned copper
per ASTM B-33• Twisted pairs
Insulation:• Premium-grade, coIor-coded S-R PVC• Color Code: See chart below
Shield:• 100% Flexfoil® aluminum/polyester,
25% overlap, foil facing out• Stranded tinned copper drain wire
Jacket:• PVC, gray• Temperature Range: –20°C to +75°C
Applications:• Audio systems• Communication circuits• Instrumentation and control use• Suggested voltage rating: 300 volts
Compliances:• NEC Article 800 Type CM
(UL: 75°C, 300V)• CSA CMG (CSA: 60°C)• UL Style 2464 (UL: 80˚C, 300V)• UL Style 2576 (UL: 80˚C, 150V)• Designed to meet UL 70,000 BTU Vertical
Tray Flame Test• Passes CSA CMG Flame Test
Packaging:• Please contact Customer Service for
packaging and color options
CATALOGNUMBER
NO. OFPAIRS
AWGSIZE
COND.STRAND.
NOM. INSULATIONTHICKNESS
INCHES mm
NOM. JACKETTHICKNESS
INCHES mm
NOMINALO.D.
NOMINAL CAP.*pF/ft
A BINCHES mm
C1670C1676C1671C1672C1673
2
4
6
9
15
22
22
22
22
22
Solid
Solid
Solid
Solid
Solid
0.010
0.010
0.010
0.010
0.010
0.25
0.25
0.25
0.25
0.25
0.81
0.81
0.81
0.81
0.81
0.218
0.249
0.292
0.338
0.419
57.0
50.0
45.0
45.0
45.0
32.0
28.0
25.0
25.0
25.0
5.54
6.32
7.42
8.59
10.64
0.032
0.032
0.032
0.032
0.032*A - Capacitance between conductors*B - Capacitance between one conductor and other conductors connected to shield
Color Code Chart
12345678
NO. OFPAIRS COLOR
Black paired with RedBlack paired with WhiteBlack paired with GreenBlack paired with BlueBlack paired with YellowBlack paired with BrownBlack paired with OrangeRed paired with White
NO. OFPAIRS COLOR
9101112131415
Red paired with GreenRed paired with BlueRed paired with YellowRed paired with BrownRed paired with OrangeGreen paired with WhiteGreen paired with Blue
Electronics Communication & Control Cable, Multi-Paired
33
Product Construction:Conductor:• 22 AWG fully annealed solid tinned copper
per ASTM B-33• Twisted pairs
Insulation:• Premium-grade, coIor-coded S-R PVC• Color Code: See chart below
Shield:• 100% Flexfoil® aluminum/polyester,
25% overlap, foil facing out• Stranded tinned copper drain wire
Jacket:• PVC, gray• Temperature Range: –20˚C to + 80˚C
Applications:• Intercom systems• Sound systems• Electronic instrumentation control systems• Suggested voltage rating: 300 volts
Compliances:• NEC Article 800 Type CM
(UL: 75°C, 300V)• UL Style 2095 (UL: 80˚C, 300V)• Designed to meet UL 70,000 BTU Vertical
Tray Flame Test
Packaging:• Please contact Customer Service for
packaging and color options
Multi-Paired, Foil ShieldUL 2095, NEC Type CM (UL) c(UL)
CATALOGNUMBER
NO. OFPAIRS
AWGSIZE
COND.STRAND.
NOM. INSULATIONTHICKNESS
INCHES mm
NOM. JACKETTHICKNESS
INCHES mm
NOMINALO.D.
NOMINAL CAP.*pF/ft
A BINCHES mm
C6451 51 22 Solid 0.010 0.25 1.27 0.715 45.025.018.160.050
Color Code Chart
12345
6
7
8
9
10
11
12
13
14
15
16
17
NO. OFPAIRS COLOR
Blue paired with WhiteOrange paired with WhiteGreen paired with WhiteBrown paired with WhiteGray paired with WhiteBlue/White striped paired with WhiteBlue/Orange stripedpaired with WhiteBlue/Green striped paired with WhiteBlue/Brown striped paired with WhiteBlue/Gray striped paired with WhiteOrange/White stripedpaired with WhiteOrange/Green stripedpaired with WhiteOrange/Brown stripedpaired with WhiteOrange/Gray stripedpaired with WhiteGreen/White striped paired with WhiteGreen/Brown stripedpaired with WhiteGreen/Gray stripedpaired with White
18
19
202122232425
26
27
28
29
30
31
32
33
34
NO. OFPAIRS COLOR
Brown/White striped paired with WhiteBrown/Gray stripedpaired with WhiteGray/White stripedpaired with WhiteBlue paired with RedOrange paired with RedGreen paired with RedBrown paired with RedGray paired with RedBlue/White striped paired with RedBlue/Orange striped paired with RedBlue/Green striped paired with RedBlue/Brown striped with RedBlue/Gray striped paired with RedOrange/White stripedpaired with RedOrange/Green stripedpaired with RedOrange/Brown stripedpaired with RedOrange/Gray stripedpaired with Red
35
36
37
38
39
404142434445
46
47
48
49
50
51
NO. OFPAIRS COLOR
Green/White stripedpaired with RedGreen/Brown striped paired with RedGreen/Gray stripedpaired with RedBrown/White stripedpaired with RedBrown/Gray stripedpaired with RedGray/White stripedpaired with RedBlue paired with BlackOrange paired with BlackGreen paired with BlackBrown paired with BlackGray paired with BlackBlue/White striped paired with BlackBlue/Orange stripedpaired with BlackBlue/Green stripedpaired with BlackBlue/Brown stripedpaired with BlackBlue/Gray stripedpaired with BlackOrange/White stripedpaired with Black
*A - Capacitance between conductors*B - Capacitance between one conductor and other conductors connected to shield
Communication & Control Cable, Multi-Paired Electronics
Power-Limited Tray Cable, Foil ShieldUL 2464, NEC Type PLTC, CSA CMG
Product Construction:Conductor:• 22 or 18 AWG fully annealed stranded
tinned copper per ASTM B-33• Twisted pairs
Insulation:• Premium-grade, coIor-coded PVC• Color code: each pair black and red
numbered at one inch intervals
Shield:• 100% Flexfoil® aluminum/polyester,
25% overlap, foil facing out• Stranded tinned copper drain wire
Jacket:• PVC, gray• Temperature range: –20°C to +105°C
Applications:• Power limited circuits• Intercom systems• Business machines• Computer interconnects• Suitably marked for appropriate tray cable
installations• Petrochemical control systems• Burglar alarms• Suggested voltage rating: 300 volts
Features:• Superior temperature characteristics• Robust, highly durable• Sunlight-resistant jacket
Compliances:• NEC Article 725 Power-Limited Tray Cable
(UL: 105°C, 300V)• UL Style 2464 (UL: 80°C, 300V)• CSA CMG (CSA: 60°C)• Designed to meet UL 70,000 BTU Vertical
Tray Flame Test• Passes CSA CMG Flame Test
Packaging:• Please contact Customer Service for
packaging and color options
CATALOGNUMBER
NO. OFPAIRS
AWGSIZE
COND.STRAND.
NOM. INSULATIONTHICKNESS
INCHES mm
NOM. JACKETTHICKNESS
INCHES mm
NOMINALO.D.
NOMINAL CAP.*pF/ft
A BINCHES mm
C0550C0551C0552C0553C0554C0555C0556C0560C0561C0562C0563C0564C0566
2
3
4
6
9
11
15
2
3
4
6
9
15
22
22
22
22
22
22
22
18
18
18
18
18
18
7/30
7/30
7/30
7/30
7/30
7/30
7/30
16/30
16/30
16/30
16/30
16/30
16/30
0.015
0.015
0.015
0.015
0.015
0.015
0.015
0.016
0.016
0.016
0.016
0.016
0.016
0.38
0.38
0.38
0.38
0.38
0.38
0.38
0.41
0.41
0.41
0.41
0.41
0.41
1.07
1.07
1.07
1.35
1.35
1.35
1.35
1.07
1.35
1.35
1.35
1.60
1.60
0.294
0.309
0.337
0.418
0.480
0.520
0.592
0.314
0.403
0.440
0.519
0.622
0.770
50.0
47.0
47.0
43.6
43.6
43.6
43.6
65.0
56.0
56.0
51.0
51.0
51.0
28.0
26.1
26.1
24.2
24.2
24.2
24.2
36.0
31.0
31.0
28.0
28.0
28.0
7.47
7.85
8.56
10.62
12.19
13.21
15.04
7.98
10.24
11.18
13.18
15.80
19.56
0.042
0.042
0.042
0.053
0.053
0.053
0.053
0.042
0.053
0.053
0.053
0.063
0.063*A - Capacitance between conductors*B - Capacitance between one conductor and other conductors connected to shield
Each pair marked and numbered
Color Code Chart
1 thru 9
10 thru 15
NO. OFPAIRS COLOR
BlackRedBlackRed
34
Electronics Communication & Control Cable, Multi-Paired
Product Construction:Conductor:• 22 AWG fully annealed stranded tinned
copper per ASTM B-33• Twisted pairs
Insulation:• Premium-grade, coIor-coded S-R PVC per UL 1061• Color Code: See chart below
Shield:• Individually shielded pairs with overall shield• 100% Flexfoil® aluminum/polyester,
25% overlap, foil facing in• Stranded tinned copper drain wire
Jacket:• PVC, beige• Temperature range: –20˚C to + 80˚C
Applications:• Computer interconnections• Data transmission• Control circuits• Industrial equipment control• Suggested voltage rating: 300 volts
Features:• Excellent high frequency properties• Mechanical durability
Compliances:• NEC Article 800 Type CM (UL: 75˚C)• UL Style 2464 (UL: 80˚C, 300V)• UL Style 2576• CSA CMG (CSA: 60°C)• Designed to meet UL 70,000 BTU Vertical
Tray Flame Test• Passes CSA CMG Flame Test
Packaging:• Please contact Customer Service for
packaging and color options
Multi-Paired, Individually ShieldedUL 2464, UL 2576, NEC Type CMR (UL) c(UL), CSA CMG
CATALOGNUMBER
NO. OFPAIRS
AWGSIZE
COND.STRAND.
NOM. INSULATIONTHICKNESS
INCHES mm
NOM. JACKETTHICKNESS
INCHES mm
NOMINALO.D.
NOMINAL CAP.*pF/ft
A BINCHES mm
C1350 2 22 7/30 0.010 0.25 0.889 0.175 x
0.280
73404.45 x
7.11
0.035
*A - Capacitance between conductors*B - Capacitance between one conductor and other conductors connected to shield
Color Code Chart
12
NO. OFPAIRS COLOR
Black/WhiteBlack/Yellow
35
Communication & Control Cable, Multi-Paired Electronics
Multi-Paired, Individually ShieldedUL 2717, UL 2835, NEC Type CM (UL) c(UL), CMH
Product Construction:Conductor:• 22 AWG fully annealed stranded tinned
copper per ASTM B-33• Twisted pairs
Insulation:• Premium-grade, coIor-coded polypropylene• Color Code: See chart below
Shield:• Individually shielded pairs• 100% Flexfoil® aluminum/polyester,
25% overlap, foil facing out• Stranded tinned copper drain wire
Jacket:• PVC, gray• Temperature range: –20˚C to +90˚C
Applications:• Where total isolation of signal is required• Computers• Control circuits• Industrial equipment• Suggested voltage rating: 300 volts
Features:• Excellent high frequency properties• Mechanical durability
Compliances:• NEC Article 800 Type CM (UL: 75˚C, 300V)• UL Style 2717 (UL: 80˚C)• UL Style 2835 (UL: 60˚C, 30V)• CSA CMH (CSA: 60˚C)• Designed to meet CSA 70,000 BTU Vertical
Tray Flame Test• Passes CSA CMH Flame Test
Packaging:• Please contact Customer Service for
packaging and color options
CATALOGNUMBER
NO. OFPAIRS
AWGSIZE
COND.STRAND.
NOM. INSULATIONTHICKNESS
INCHES mm
NOM. JACKETTHICKNESS
INCHES mm
NOMINALO.D.
NOMINAL CAP.*pF/ft
A BINCHES mm
C1352 2 22 7/30
CATALOGNUMBER
NO. OFPAIRS
AWGSIZE
COND.STRAND.
NOM. INSULATIONTHICKNESS
INCHES mm
NOM. JACKETTHICKNESS
INCHES mm
NOMINALO.D.
NOMINAL CAP.pF/ft
A BINCHES mm
0.007 0.18 0.51 0.160 55.030.04.060.020
NEC Type CM (UL) c(UL) CMH
UL Style 2835, CM (UL) c(UL) CMHC1353* 2 22 7/30 0.010 0.25 0.71 0.208 45.025.05.280.028
*A - Capacitance between conductors*B - Capacitance between one conductor and other conductors connected to shield
A - Capacitance between conductorsB - Capacitance between one conductor and other conductors connected to shield* Individually shielded with overall shield
Color Code Chart
12
NO. OF PAIRS COLOR
Black/RedGreen/White
Color Code Chart
12
NO. OF PAIRS COLOR
Black/RedGreen/White
36
Electronics Communication & Control Cable, Multi-Paired
Product Construction:Conductor:• 22 or 18 AWG fully annealed stranded
tinned copper per ASTM B-33 • Twisted pairs
Insulation:• Premium-grade, coIor-coded PVC • Color Code: Each pair black and red
numbered at one inch intervals
Shield:• Pairs are 100% individually shielded with
Flexfoil® aluminum/polyester, foil facing in• Stranded tinned copper drain wire each pair
Jacket: • PVC, gray• Temperature range: –20°C to + 105°C
Applications: • Power limited circuits • Intercom systems • Business machines • Cash registers • Computer interconnects • Suitably marked for appropriate tray cable
installations • Burglar alarms• Suggested voltage rating: 300 volts
Features:• Superior temperature characteristics • Robust, highly durable • Sunlight-resistant jacket
Compliances:• NEC Article 725 Power-Limited Tray Cable
(UL: 105°C, 300V) • NEC Article 727 Instrumentation Tray Cable
(UL: 105°C)• UL Style 2464 (UL: 80°C)• CSA CMG (CSA: 60°C)• Designed to meet UL 70,000 BTU Vertical
Tray Flame Test• Passes CSA CMG Flame Test
Packaging:• Please contact Customer Service for
packaging and color options
Power-Limited Tray Cable, Individually Shielded UL 2464, NEC Type PLTC AND ITC, CSA CMG
CATALOGNUMBER
NO. OFPAIRS
AWGSIZE
COND.STRAND.
NOM. INSULATIONTHICKNESS
INCHES mm
NOM. JACKETTHICKNESS
INCHES mm
NOMINALO.D.
NOMINAL CAP.*pF/ft
A BINCHES mm
C0570C0571C0572C0573C0574C0575C0584C0585C0586C0587C0588C0589C0590
2
3
4
6
9
11
2
3
4
6
9
11
15
22
22
22
22
22
22
18
18
18
18
18
18
18
7/30
7/30
7/30
7/30
7/30
7/30
16/30
16/30
16/30
16/30
16/30
16/30
16/30
0.016
0.016
0.016
0.016
0.016
0.016
0.016
0.016
0.016
0.016
0.016
0.016
0.016
0.41
0.41
0.41
0.41
0.41
0.41
0.41
0.41
0.41
0.41
0.41
0.41
0.41
1.07
1.07
1.07
1.35
1.35
1.35
1.07
1.35
1.35
1.35
1.60
1.60
1.60
0.327
0.345
0.378
0.469
0.542
0.589
0.380
0.437
0.478
0.566
0.679
0.738
0.845
63.0
63.0
63.0
63.0
63.0
63.0
81.0
81.0
81.0
81.0
81.0
81.0
81.0
35.0
35.0
35.0
35.0
35.0
35.0
45.0
45.0
45.0
45.0
45.0
45.0
45.0
8.31
8.76
9.60
11.91
13.77
14.96
9.65
11.10
12.14
14.38
17.25
18.75
21.46
0.042
0.042
0.042
0.053
0.053
0.053
0.042
0.053
0.053
0.053
0.063
0.063
0.063*A - Capacitance between conductors*B - Capacitance between one conductor and other conductors connected to shield
37
Color Code Chart
1 thru 9
NO. OFPAIRS COLOR
BlackRed
Each pair marked and numbered
Electronics
38
Computer Cable 4
Index PageMulti-Conductor, Foil Shield 39-40Multi-Conductor, Foil/Braid Shield 41-42Multi-Conductor, Foil/Braid Shield, Lo-Cap® 43Multi-Paired, Foil Shield 44Multi-Paired, Foil Shield, Lo-Cap® 45Multi-Paired, Foil/Braid Shield 46Multi-Paired, Foil/Braid Shield, Lo-Cap® 47-50Multi-Paired, IndividuallyFoil Shielded 51-53Multi-Paired, IndividuallyFoil Shielded, Lo-Cap® 54Multi-Paired, IndividuallyFoil/Braid Shielded,Lo-Cap® 55
General Cable manufacturesa comprehensive line ofcomputer cables.
This complete line of pairedand unpaired, shieldedcomputer cables—which areUL and CSA listed—are usedprimarily for the internal orexternal interconnection ofelectronic equipment andcomputers. Applicationsinclude data transmission,CAD/CAM, telemetering, datadisplays, computer print-out,credit verification systems andsimilar applications.
General Cable also offers avariety of put-ups for computercables to meet your individualrequirements.
Our products aremanufactured to meet thelatest UL, CSA and NECrequirements and approvals.
39
Electronics Computer Cable
Product Construction:Conductor:• 24 AWG fully annealed stranded tinned
copper per ASTM B-33
Insulation:• Premium-grade, coIor-coded S-R PVC
per UL 1061• Color Code: See charts below
Shield:• 100% Flexfoil® aluminum/polyester
with 25% overlap, foil facing out• Stranded tinned copper drain wire
Jacket:• PVC, gray• Temperature Range: – 20˚C to + 80˚C
Applications:• Computer interconnections• Data transmission• Control circuits• Industrial equipment control• Suitable for EIA RS-232 applications• Suggested voltage rating: 300 volts
Compliances:• NEC Article 800 Type CMR (UL: 75˚C)• UL Style 2464 (UL: 80°C, 300V)• CSA CMG (CSA: 60°C)• Designed to meet UL 70,000 BTU Vertical
Tray Flame Test• Passes CSA CMG Flame Test
Packaging:• Please contact Customer Service for
packaging and color options
Multi-Conductor, Foil ShieldUL 2464, NEC Type CMR (UL) c(UL), CSA CMG
CATALOGNUMBER
C0740C0741C0742C0753C0743C0754C0744C0755C0745
2
3
4
5
6
7
8
9
10
24
24
24
24
24
24
24
24
24
Color Code Chart 2 Per ICEA - For cables of 15 to 50 conductors
123456789
1011121314151617
BlackWhiteRedLight GreenOrangeLight BlueWhite/BlackRed/BlackLight Green/BlackOrange/BlackLight Blue/BlackBlack/WhiteRed/WhiteLight Green/WhiteLight Blue/WhiteBlack/RedWhite/Red
1819202122232425262728293031323334
Orange/RedLight Blue/RedRed/GreenOrange/GreenBlack/White/RedWhite/Black/RedRed/Black/WhiteLight Green/Black/WhiteOrange/Black/WhiteLight Blue/Black/WhiteBlack/Red/GreenWhite/Red/GreenRed/Black/GreenLight Green/Black/OrangeOrange/Black/GreenLight Blue/White/OrangeBlack/White/Orange
35363738394041424344454647484950
White/Red/OrangeOrange/White/BlueWhite/Red/BlueBlack/White/GreenWhite/Black/GreenRed/White/GreenLight Green/White/BlueOrange/Red/GreenLight Blue/Red/GreenBlack/White/BlueWhite/Black/BlueRed/White/BlueLight Green/Orange/RedOrange/Red/BlueLight Blue/Red/OrangeBlack/Orange/Red
Color Code Chart 1
NO. OFCOND.
AWGSIZE
7/32
7/32
7/32
7/32
7/32
7/32
7/32
7/32
7/32
COND.STRAND.
NOM.INSULATIONTHICKNESS
INCHES mm
NOM. JACKET
THICKNESSINCHES mm
NOMINALO.D.
INCHES mm
NOMINAL DCRΩ/kft
@ 20˚CCOND. SHLD.
NOMINAL CAP.*pF/ft
A B
0.010
0.010
0.010
0.010
0.010
0.010
0.010
0.010
0.010
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.032
0.032
0.032
0.032
0.032
0.032
0.032
0.032
0.032
0.81
0.81
0.81
0.81
0.81
0.81
0.81
0.81
0.81
0.157
0.164
0.175
0.188
0.201
0.210
0.215
0.228
0.245
3.99
4.17
4.45
4.78
5.11
5.11
5.46
5.79
6.22
26.0
26.0
26.0
26.0
26.0
26.0
26.0
26.0
26.0
7.2
7.2
7.2
7.2
7.2
7.2
7.2
7.2
7.2
36.0
33.0
33.0
33.0
30.0
30.0
30.0
30.0
30.0
64.0
59.0
59.0
59.0
55.0
55.0
55.0
55.0
55.0
C0746C0747C0748C0749C0750C0751
15
20
25
30
40
50
24
24
24
24
24
24
Color Code Chart 27/32
7/32
7/32
7/32
7/32
7/32
0.010
0.010
0.010
0.010
0.010
0.010
0.25
0.25
0.25
0.25
0.25
0.25
0.032
0.032
0.032
0.032
0.032
0.032
0.81
0.81
0.81
0.81
0.81
0.81
0.276
0.303
0.333
0.351
0.391
0.439
7.01
7.70
8.46
8.92
9.93
11.15
26.0
26.0
26.0
26.0
26.0
26.0
7.2
7.2
7.2
7.2
7.2
7.2
30.0
30.0
30.0
30.0
30.0
30.0
55.0
55.0
55.0
55.0
55.0
55.0 *A - Capacitance between conductors*B - Capacitance between one conductor and other conductors connected to shield
Color Code Chart 1 - For cables up to and including 10 conductors
12345
NO. OFCOND. COLOR
BlackWhiteRedLight GreenLight Brown
6789
10
NO. OFCOND. COLOR
Light BlueOrangeYellowVioletGray
NO. OFCOND. COLOR
NO. OFCOND. COLOR
NO. OFCOND. COLOR
40
Computer Cable Electronics
Multi-Conductor, Foil ShieldUL 2464, NEC Type CM (UL) c(UL) or CMR (UL) c(UL), CSA CMG
Product Construction:Conductor:• 22 or 20 AWG fully annealed stranded
tinned copper per ASTM B-33
Insulation:• Premium-grade, coIor-coded S-R PVC
or PVC• Color Code: See chart below
Shield:• 100% Flexfoil® aluminum/polyester
with 25% overlap, minimum, foil facing out• Stranded tinned copper drain wire
Jacket:• PVC, gray• Temperature Range: – 20˚C to + 80˚C
Applications:• Computer interconnections• Data transmission• Control circuits• Industrial equipment control• Suitable for EIA RS-232 applications• Suggested voltage rating: 300 volts
Compliances:• NEC Article 800 Type CM - 20 or 22 AWG
(UL: 75˚C)• NEC Article 800 Type CMR - 20 or 22 AWG
(UL: 75˚C)• UL Style 2464 (UL: 80˚C, 300V)• CSA CMG (CSA: 60˚C)• Designed to meet UL 70,000 BTU Vertical
Tray Flame Test• Passes CSA CMG Flame Test
Packaging:• Please contact Customer Service for
packaging and color options
CATALOGNUMBER
C0760C0761C0762C0763C0764C0765C0766C0767C0768
2
3
4
6
8
10
15
20
25
22
22
22
22
22
22
22
22
22
S-R PVC
NO. OFCOND.
AWGSIZE
7/30
7/30
7/30
7/30
7/30
7/30
7/30
7/30
7/30
COND.STRAND.
NOM.INSULATIONTHICKNESS
INCHES mm
NOM. JACKET
THICKNESSINCHES mm
NOMINALO.D.
INCHES mm
NOMINAL DCRΩ/kft
@ 20˚CCOND. SHLD.
NOMINAL CAP.*pF/ft
A B
0.010
0.010
0.010
0.010
0.010
0.010
0.010
0.010
0.010
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.032
0.032
0.032
0.032
0.032
0.032
0.032
0.032
0.032
0.81
0.81
0.81
0.81
0.81
0.81
0.81
0.81
0.81
0.169
0.177
0.190
0.219
0.235
0.269
0.304
0.335
0.369
4.29
4.50
4.83
5.56
5.97
6.83
7.72
8.51
9.37
15.0
15.0
15.0
15.0
15.0
15.0
15.0
15.0
15.0
13.0
13.0
12.0
12.0
10.7
10.7
10.7
9.1
9.1
36.0
36.0
36.0
34.0
34.0
34.0
34.0
34.0
34.0
65.0
65.0
65.0
61.0
61.0
61.0
61.0
61.0
61.0
C0780C0781C0782C0783C0784C0785C0786C0787C0788
2
3
4
6
8
10
15
20
25
20
20
20
20
20
20
20
20
20
PVC7/28
7/28
7/28
7/28
7/28
7/28
7/28
7/28
7/28
0.016
0.016
0.016
0.016
0.016
0.016
0.016
0.016
0.016
0.41
0.41
0.41
0.41
0.41
0.41
0.41
0.41
0.41
0.032
0.032
0.032
0.032
0.032
0.032
0.032
0.032
0.032
0.81
0.81
0.81
0.81
0.81
0.81
0.81
0.81
0.81
0.207
0.217
0.236
0.276
0.297
0.345
0.393
0.435
0.483
5.26
5.51
5.99
7.01
7.54
8.76
9.98
11.05
12.27
11.0
11.0
11.0
11.0
11.0
11.0
11.0
11.0
11.0
12.0
12.0
9.1
9.1
9.1
7.9
7.9
7.1
7.1
39.0
39.0
39.0
37.0
37.0
37.0
37.0
37.0
40.0
70.0
70.0
70.0
66.0
66.0
66.0
66.0
66.0
72.0
*A - Capacitance between conductors*B - Capacitance between one conductor and other conductors connected to shield
Color Code Chart Per ICEA
123456789
NO. OFCOND. COLOR
BlackWhiteRedGreenOrangeBlueWhite/BlackRed/BlackGreen/Black
101112131415161718
NO. OFCOND. COLOR
Orange/BlackBlue/BlackBlack/WhiteRed/WhiteGreen/WhiteBlue/WhiteBlack/RedWhite/RedOrange/Red
19202122232425
NO. OFCOND. COLOR
Blue/RedRed/GreenOrange/GreenBlack/White/RedWhite/Black RedRed/Black/WhiteGreen/Black/White
41
Electronics Computer Cable
Product Construction:Conductor:• 28 and 24 AWG fully annealed stranded
tinned copper per ASTM B-33
Insulation:• Premium-grade, coIor-coded S-R PVC
per UL 1061• Color Code: See charts below
Shield:• 100% Flexfoil® aluminum/polyester
with 25% overlap, minimum, foil facing out• Stranded tinned copper drain wire
(28 AWG only)• 65% tinned copper braid
Jacket:• PVC, gray• Temperature Range: – 20˚C to + 80˚C
Applications:• Computers• Industrial equipment• Data transmission• Control circuits• Suitable for EIA RS-232 applications• Suggested voltage rating: 300 volts
Features:• Braid shield provides good flexibility• Superior shielding where noise rejection
is critical• Assists system designers in meeting FCC
Docket 20780 demands
Compliances:• NEC Article 725 Type CL2 - 28 AWG
(UL: 75˚C)• NEC Article 800 Type CM - 24 AWG
(UL: 75˚C)• UL Style 2464 (UL: 80°C, 300V)• CSA CMG (CSA: 60˚C)• Designed to meet UL 70,000 BTU Vertical
Tray Flame Test• Passes CSA CMG Flame Test
Packaging:• Please contact Customer Service for
packaging and color options
Multi-Conductor, Foil/Braid ShieldUL 2464, NEC Type CL2 or CM (UL) c(UL), CSA CMG
CATALOGNUMBER
C0939*C0940*C0941*C0942*C0943*C0944*C0945*C0946*C0947C0948C0951C0952C0953C0954C0955C0956C0957C0958C0959C0960C0961
3
4
5
6
7
8
9
10
15
25
3
4
5
6
7
8
9
10
15
20
25
28
28
28
28
28
28
28
28
28
28
24
24
24
24
24
24
24
24
24
24
24
NO. OFCOND.
AWGSIZE
7/36
7/36
7/36
7/36
7/36
7/36
7/36
7/36
7/36
7/36
7/32
7/32
7/32
7/32
7/32
7/32
7/32
7/32
7/32
7/32
7/32
COND.STRAND.
NOM.INSULATIONTHICKNESS
INCHES mm
NOM. JACKET
THICKNESSINCHES mm
NOMINALO.D.
INCHES mm
NOMINAL DCRΩ/kft
@ 20˚CCOND. SHLD.
NOMINAL CAP.**pF/ft
A B
0.010
0.010
0.010
0.010
0.010
0.010
0.010
0.010
0.010
0.010
0.010
0.010
0.010
0.010
0.010
0.010
0.010
0.010
0.010
0.010
0.010
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.032
0.032
0.032
0.032
0.032
0.032
0.032
0.032
0.032
0.032
0.032
0.032
0.032
0.032
0.032
0.032
0.032
0.032
0.032
0.032
0.032
0.81
0.81
0.81
0.81
0.81
0.81
0.81
0.81
0.81
0.81
0.81
0.81
0.81
0.81
0.81
0.81
0.81
0.81
0.81
0.81
0.81
0.166
0.176
0.186
0.196
0.196
0.207
0.217
0.231
0.256
0.301
0.186
0.197
0.210
0.223
0.223
0.237
0.250
0.267
0.298
0.325
0.355
4.22
4.47
4.72
4.98
4.98
5.26
5.51
5.87
6.50
7.65
4.72
5.00
5.33
5.66
5.66
6.02
6.35
6.78
7.57
8.26
9.02
67.5
67.5
67.5
67.5
67.5
67.5
67.5
67.5
67.5
67.5
25.7
25.7
25.7
25.7
25.7
25.7
25.7
25.7
25.7
25.7
25.7
4.6
4.7
4.6
4.1
4.0
4.1
6.3
7.0
10.2
4.5
5.3
5.5
4.4
4.6
4.6
3.8
3.9
4.2
3.6
4.5
3.5
26.0
26.0
26.0
25.0
25.0
25.0
20.0
20.0
20.0
20.0
33.0
33.0
33.0
30.0
30.0
30.0
30.0
30.0
30.0
30.0
30.0
47.0
47.0
47.0
44.0
44.0
44.0
36.0
36.0
36.0
36.0
59.0
59.0
59.0
55.0
55.0
55.0
55.0
55.0
55.0
55.0
55.0 **A - Capacitance between conductors**B - Capacitance between one conductor and other conductors connected to shield* Color Code Chart 1. Remaining items Color Code Chart 2
Color Code Chart 1
12345
NO. OFCOND. COLOR
BlackWhiteRedLight GreenLight Brown
6789
10
NO. OFCOND. COLOR
Light BlueOrangeYellowVioletGray
Color Code Chart 2 Per ICEA
123456789
NO. OFCOND. COLOR
BlackWhiteRedLight GreenOrangeLight BlueWhite/BlackRed/BlackLight Green/Black
101112131415161718
NO. OFCOND. COLOR
Orange/BlackLight Blue/BlackBlack/WhiteRed/WhiteLight Green/WhiteLight Blue/WhiteBlack/RedWhite/RedOrange/Red
19202122232425
NO. OFCOND. COLOR
Light Blue/RedRed/GreenOrange/GreenBlack/White/RedWhite/Black RedRed/Black/WhiteLight Green/Black/White
42
Computer Cable Electronics
Multi-Conductor, Foil/Braid ShieldUL 2464, NEC Type CM (UL) c(UL), CSA CMG
Product Construction:Conductor:• 22 AWG fully annealed stranded tinned
copper per ASTM B-33
Insulation:• Premium-grade, coIor-coded S-R PVC
per UL 1061• Color Code: See chart below
Shield:• 100% Flexfoil® aluminum/polyester
with 25% overlap, minimum, foil facing out• 65% tinned copper braid
Jacket:• PVC, gray• Temperature Range: – 20°C to + 80˚C
Applications:• Computers• Industrial equipment• Data transmission• Control circuits• Suitable for EIA RS-232 applications• Suggested voltage rating: 300 volts
Features:• Braid shield provides good flexibility• Superior shielding where noise rejection
is critical• Assists system designers in meeting FCC
Docket 20780 demands
Compliances:• NEC Article 800 Type CM (UL: 75˚C)• UL Style 2464 (UL: 80°C, 300V)• CSA CMG (CSA: 60˚C)• Designed to meet UL 70,000 BTU Vertical
Tray Flame Test• Passes CSA CMG Flame Test
Packaging:• Please contact Customer Service for
packaging and color options
CATALOGNUMBER
C0971C0972C0973C0974C0975C0976C0977C0978C0979C0980C0981
3
4
5
6
7
8
9
10
15
20
25
22
22
22
22
22
22
22
22
22
22
22
NO. OFCOND.
AWGSIZE
7/30
7/30
7/30
7/30
7/30
7/30
7/30
7/30
7/30
7/30
7/30
COND.STRAND.
NOM.INSULATIONTHICKNESS
INCHES mm
NOM. JACKET
THICKNESSINCHES mm
NOMINALO.D.
INCHES mm
NOMINAL DCRΩ/kft
@ 20˚CCOND. SHLD.
NOMINAL CAP.*pF/ft
A B
0.010
0.010
0.010
0.010
0.010
0.010
0.010
0.010
0.010
0.010
0.010
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.032
0.032
0.032
0.032
0.032
0.032
0.032
0.032
0.032
0.032
0.032
0.81
0.81
0.81
0.81
0.81
0.81
0.81
0.81
0.81
0.81
0.81
0.199
0.212
0.226
0.241
0.241
0.257
0.272
0.291
0.326
0.357
0.391
5.05
5.38
5.74
6.12
6.12
6.53
6.91
7.39
8.28
9.07
9.93
16.6
16.6
16.6
16.6
16.6
16.6
16.6
16.6
16.6
16.6
16.6
5.6
4.4
4.7
3.8
6.2
4.0
3.4
3.6
3.6
3.9
2.7
36.0
36.0
36.0
34.0
34.0
34.0
34.0
34.0
34.0
34.0
34.0
66.0
66.0
66.0
60.0
60.0
60.0
60.0
60.0
60.0
60.0
60.0 *A - Capacitance between conductors*B - Capacitance between one conductor and other conductors connected to shield
Color Code Chart Per ICEA
123456789
NO. OFCOND. COLOR
BlackWhiteRedLight GreenOrangeLight BlueWhite/BlackRed/BlackLight Green/Black
101112131415161718
NO. OFCOND. COLOR
Orange/BlackLight Blue/BlackBlack/WhiteRed/WhiteLight Green/WhiteLight Blue/WhiteBlack/RedWhite/RedOrange/Red
19202122232425
NO. OFCOND. COLOR
Light Blue/RedRed/GreenOrange/GreenBlack/White/RedWhite/Black/RedRed/Black/WhiteLight Green/Black/White
43
Electronics Computer Cable
Multi-Conductor, Foil/Braid Shield, Lo-Cap®
UL 2919, NEC Type CL2 or CM (UL) c(UL), CMH, CSA CMH
Product Construction:Conductor:• 28 and 24 AWG fully annealed stranded
tinned copper per ASTM B-33
Insulation:• Premium grade foamed Lo-Cap® color
coded polypropylene• Color Code: See chart below
Shield:• 100% Flexfoil® aluminum/polyester
with 25% overlap, minimum, foil facing out• Stranded tinned copper drain wire• 70% tinned copper braid
Jacket:• PVC, gray• Temperature Range: – 20˚C to + 80˚C
Applications:• High speed computers• Industrial equipment• Control circuits• Designed for low capacitance applications• Suitable for EIA RS-232 and RS-423
CAD/CAM applications• Suggested voltage rating: 30 volts
Features:• Braid shield provides good flexibility• Superior shielding where noise rejection
is critical• Assists system designers in meeting FCC
Docket 20780 demands
Compliances:• NEC Article 800 Type CM (UL: 75˚C)• UL Style 2919 (UL: 80˚C, 30V)• CSA CMH (CSA: 60˚C)• Designed to Meet UL 70,000 BTU Vertical
Tray Flame Test• Passes CSA CMH Flame Test
Packaging:• 1000' (305 m) Spools or Reels• 500' (152 m) Spools or Reels• Other put-ups available—consult
Customer Service
*A - Capacitance between conductors*B - Capacitance between one conductor and other conductors connected to shieldVp = 78%Impedance: 100
Color Code Chart 1 For cables up to and including 10 conductors
12345
NO. OFCOND. COLOR
BlackWhiteRedLight GreenBrown
6789
10
NO. OFCOND. COLOR
Light BlueOrangeYellowVioletGray
CATALOGNUMBER
C0530C0531C0532C0533C0534C0535C0536C0537C0538C0539
3
4
5
6
7
8
9
10
15
25
28 AWG (7/36): CL2, CSA CMH
NO. OFCOND.
NOM. INSULATIONTHICKNESS
INCHES mm
NOM. JACKET
THICKNESSINCHES mm
NOMINALO.D.
INCHES mm
NOMINAL DCRΩ/kft
COND. SHLD.
NOMINAL CAP.*pF/ft
A B
0.016
0.016
0.016
0.016
0.016
0.016
0.016
0.016
0.016
0.016
0.41
0.41
0.41
0.41
0.41
0.41
0.41
0.41
0.41
0.41
0.032
0.032
0.032
0.032
0.032
0.032
0.032
0.032
0.032
0.032
0.81
0.81
0.81
0.81
0.81
0.81
0.81
0.81
0.81
0.81
0.192
0.205
0.218
0.232
0.232
0.247
0.261
0.279
0.312
0.373
4.88
5.21
5.54
5.89
5.89
6.27
6.63
7.09
7.92
9.47
64.9
64.9
64.9
64.9
64.9
64.9
64.9
64.9
64.9
64.9
7.8
5.9
5.9
6.2
6.2
4.8
4.9
5.2
4.2
4.0
9.5
9.5
9.5
9.0
9.0
9.0
9.0
9.0
9.0
9.0
17.0
17.0
17.0
16.0
16.0
16.0
16.0
16.0
16.0
16.0
C0680C0681C0682C0683C0684C0685C0686C0687C0688C0689
3
4
5
6
7
8
9
10
15
25
0.016
0.016
0.016
0.016
0.016
0.016
0.016
0.016
0.016
0.016
0.41
0.41
0.41
0.41
0.41
0.41
0.41
0.41
0.41
0.41
0.032
0.032
0.032
0.032
0.032
0.032
0.032
0.032
0.032
0.032
0.81
0.81
0.81
0.81
0.81
0.81
0.81
0.81
0.81
0.81
0.211
0.227
0.242
0.259
0.259
0.276
0.293
0.315
0.354
0.427
5.36
5.77
6.15
6.58
6.58
7.01
7.44
8.00
8.99
10.85
25.7
25.7
25.7
25.7
25.7
25.7
25.7
25.7
25.7
25.7
3.8
3.8
3.8
3.2
3.2
3.2
3.6
3.6
3.6
3.6
11.9
11.9
11.9
11.2
11.2
11.2
11.2
11.2
11.2
11.2
21.5
21.5
21.5
20.2
20.2
20.2
20.2
20.2
20.2
20.2
24 AWG (7/32): CM (UL) c(UL) CMH
Color Code Chart 2 Per ICEA For cables up to 15
123456789
NO. OFCOND. COLOR
BlackWhiteRedLight GreenOrangeLight BlueWhite/BlackRed/BlackLight Green/Black
101112131415
NO. OFCOND. COLOR
Orange/BlackLight Blue/BlackBlack/WhiteRed/WhiteLight Green/WhiteLight Blue/White
44
Computer Cable Electronics
Multi-Paired, Foil ShieldUL 2464, NEC Type CMR (UL) c(UL), CSA CMG
Product Construction:Conductor:• 24 AWG fully annealed stranded tinned
copper per ASTM B-33• Twisted pairs
Insulation:• Premium-grade, coIor-coded S-R PVC
per UL 1061• Color Code: See chart below
Shield:• 100% Flexfoil® aluminum/polyester
with 25% overlap, minimum, foil facing out• Stranded tinned copper drain wire
Jacket:• PVC, gray• Temperature Range: – 20˚C to + 80˚C
Applications:• Computers• Industrial equipment• Data transmission• Control circuits• Suitable for EIA RS-232 applications• Suggested voltage rating: 300 volts
Features:• Superior shielding where noise rejection
is critical• Assists system designers in meeting FCC
Docket 20780 demands
Compliances:• NEC Article 800 Type CMR (UL: 75°C)• UL Style 2464 (UL: 80˚C, 300V)• CSA CMG (CSA, 60°C)• Designed to meet UL 70,000 BTU Vertical
Tray Flame Test• Passes CSA CMG Flame Test
Packaging:• Please contact Customer Service for
packaging and color options
CATALOGNUMBER
C0600C0601C0602C0603C0604C0605C0606C0607C0608C0609C0610C0611C0612
1
2
3
4
5
6
7
8
9
10
15
19
25
24
24
24
24
24
24
24
24
24
24
24
24
24
NO. OFPAIRS
AWGSIZE
7/32
7/32
7/32
7/32
7/32
7/32
7/32
7/32
7/32
7/32
7/32
7/32
7/32
COND.STRAND.
NOM.INSULATIONTHICKNESS
INCHES mm
NOM. JACKET
THICKNESSINCHES mm
NOMINALO.D.
INCHES mm
NOMINAL DCRΩ/kft
COND. SHLD.
NOMINAL CAP.*pF/ft
A B
0.010
0.010
0.010
0.010
0.010
0.010
0.010
0.010
0.010
0.010
0.010
0.010
0.010
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.032
0.032
0.032
0.032
0.032
0.032
0.032
0.032
0.032
0.032
0.032
0.032
0.032
0.81
0.81
0.81
0.81
0.81
0.81
0.81
0.81
0.81
0.81
0.81
0.81
0.81
0.157
0.214
0.225
0.245
0.265
0.287
0.287
0.309
0.331
0.359
0.410
0.432
0.505
3.99
5.44
5.72
6.23
6.73
7.29
7.29
7.85
8.41
9.12
10.41
10.97
12.84
25.7
25.7
25.7
25.7
25.7
25.7
25.7
25.7
25.7
25.7
25.7
25.7
25.7
7.2
7.2
7.2
7.2
7.2
7.2
7.2
7.2
7.2
7.2
7.2
7.2
7.2
19.7
28.7
25.7
25.7
25.7
23.7
23.7
23.7
23.7
23.7
23.7
23.7
23.7
21.5
21.5
21.5
20.2
20.2
42.7
42.7
42.7
42.7
42.7
42.7
42.7
42.7
Color Code Chart
123456789
10111213
NO. OFPAIRS COLOR
Black with RedBlack with WhiteBlack with GreenBlack with BlueBlack with YellowBlack with BrownBlack with OrangeRed with WhiteRed with GreenRed with BlueRed with YellowRed with BrownRed with Orange
1415161718192021222324252627
NO. OFPAIRS COLOR
Green with WhiteGreen with BlueGreen with YellowGreen with BrownGreen with OrangeWhite with BlueWhite with YellowWhite with BrownWhite with OrangeBlue with YellowBlue with BrownBlue with OrangeBrown with YellowBrown with Orange
C0720C0721C0722C0723C0724C0725C0726C0728C0729C0730
1
2
3
4
5
6
9
15
19
27
22
22
22
22
22
22
22
22
22
22
7/30
7/30
7/30
7/30
7/30
7/30
7/30
7/30
7/30
7/30
0.010
0.010
0.010
0.010
0.010
0.010
0.010
0.010
0.040
0.040
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.032
0.032
0.032
0.032
0.032
0.032
0.032
0.032
0.032
0.032
0.81
0.81
0.81
0.81
0.81
0.81
0.81
0.81
0.81
0.81
0.169
0.234
0.246
0.269
0.292
0.317
0.367
0.457
0.482
0.605
4.29
5.94
6.25
6.83
7.42
8.05
9.32
11.62
12.24
15.37
16.6
16.6
16.6
16.6
16.6
16.6
16.6
16.6
16.6
16.6
6.2
6.2
6.2
6.2
6.2
6.2
6.2
6.2
6.2
6.2
40.4
32.3
27.8
27.8
27.8
25.5
25.5
25.5
25.5
26.0
72.6
58.1
50.1
50.1
50.1
45.9
45.9
45.9
45.9
46.0 *A - Capacitance between conductors*B - Capacitance between one conductor and other conductors connected to shield
45
Electronics Computer Cable
Multi-Paired, Foil Shield, Lo-Cap®
UL 2448, NEC Type CM (UL) c(UL) CMH
Product Construction:Conductor:• 24 AWG fully annealed stranded tinned
copper per ASTM B-33• Twisted pairs
Insulation:• Premium-grade, coIor-coded polyethylene• Color Code: See chart below
Shield:• 100% Flexfoil® aluminum/polyester
with 25% overlap, minimum, foil facing out• Stranded tinned copper drain wire
Jacket:• PVC, gray• Temperature Range: – 20˚C to + 75°C
Applications:• Computers• Industrial equipment• Data transmission• Control circuits• Suitable for low capacitance applications• Suggested voltage rating: 30 volts
Compliances:• NEC Article 800 Type CM (UL: 75˚C)• UL Style 2448 (UL: 60˚C, 30V)• Designed to meet UL 70,000 BTU Vertical
Tray Flame Test• CSA CMH (CSA: 60˚C)• Passes CSA CMH Flame Test
Packaging:• Please contact Customer Service for
packaging and color options
CATALOGNUMBER
C0890C0901C0893C0894C0899C0896C0897
2
3
4
5
6
9
12.5
24
24
24
24
24
24
24
NO. OFPAIRS
AWGSIZE
7/32
7/32
7/32
7/32
7/32
7/32
7/32
COND.STRAND.
NOM.INSULATIONTHICKNESS
IN mm
0.015
0.015
0.015
0.015
0.015
0.015
0.015
0.38
0.38
0.38
0.38
0.38
0.38
0.38
NOM. JACKET
THICKNESSIN mm
0.032
0.032
0.032
0.032
0.032
0.032
0.038
0.81
0.81
0.81
0.81
0.81
0.81
0.97
NOMINALO.D.
IN mm
0.247
0.261
0.277
0.310
0.336
0.391
0.459
6.27
6.63
7.04
7.87
8.53
9.93
11.66
NOMINAL DCRΩ/kft
COND. SHLD.
14.8
14.2
14.2
14.2
13.2
13.2
13.2
26.7
25.5
25.5
25.5
23.8
23.8
23.8
VEL.OF
PROP.,%
NOM.IMP.,Ω
66
66
66
66
66
66
66
100
100
100
100
100
100
100
NOMINALCAP.*pF/ft
A B
25.7
25.7
25.7
25.7
25.7
25.7
25.7
7.2
7.2
7.2
7.2
7.2
7.2
7.2 *A - Capacitance between conductors*B - Capacitance between one conductor and other conductors connected to shield
Color Code Chart
123456
Single Conductor: Green with Yellow Stripe
NO. OFPAIRS COLOR
Black paired with WhiteRed paired with GreenBrown paired with BlueOrange paired with YellowViolet paired with GrayTan paired with Pink
NO. OFPAIRS COLOR
789
101112
White/Blue paired with Blue/WhiteWhite/Brown paired with Brown/WhiteWhite/Orange paired with Orange/WhiteWhite/Green paired with Green/WhiteWhite/Red paired with Red/WhiteWhite/Black paired with Black/White
46
Computer Cable Electronics
CATALOGNUMBER
C0620C0621C0622C0623C0624C0625C0626C0628C0630
2
3
4
5
6
7
8
10
12.5
24
24
24
24
24
24
24
24
24
NO. OFPAIRS
AWGSIZE
7/32
7/32
7/32
7/32
7/32
7/32
7/32
7/32
7/32
COND.STRAND.
NOM.INSULATIONTHICKNESS
INCHES mm
NOM. JACKET
THICKNESSINCHES mm
NOMINALO.D.
INCHES mm
NOMINAL DCRΩ/kft
COND. SHLD.
NOMINAL CAP.*pF/ft
A B
0.010
0.010
0.010
0.010
0.010
0.010
0.010
0.010
0.010
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.032
0.032
0.032
0.032
0.032
0.032
0.032
0.032
0.032
0.81
0.81
0.81
0.81
0.81
0.81
0.81
0.81
0.81
0.235
0.246
0.266
0.292
0.313
0.313
0.336
0.386
0.396
5.97
6.25
6.76
7.42
7.95
7.95
8.53
9.80
10.06
25.7
25.7
25.7
25.7
25.7
25.7
25.7
25.7
25.7
5.4
5.0
4.5
4.6
2.9
3.1
4.1
2.6
3.6
29.5
26.4
26.4
26.4
24.4
24.4
24.4
24.4
24.4
53.0
47.6
47.6
47.6
43.9
43.9
43.9
43.9
43.9
Multi-Paired, Foil/Braid ShieldUL 2464, NEC Type CMR (UL) c(UL), CSA CMG
Product Construction:Conductor:• 22 and 24 AWG fully annealed stranded
tinned copper per ASTM B-33• Twisted pairs
Insulation:• Premium-grade, coIor-coded S-R PVC
per UL 1061• Color Code: See chart below
Shield:• 100% Flexfoil® aluminum/polyester
with 25% overlap, minimum, foil facing out• 65% tinned copper braid
Jacket:• PVC, gray• Temperature Range: – 20˚C to + 80˚C
Applications:• Computers• Industrial equipment• Data transmission• Control circuits• Suitable for EIA RS-232 applications• Suggested voltage rating: 300 volts
Features:• Braid shield provides good flexibility• Superior shielding where noise rejection
is critical• Assists system designers in meeting FCC
Docket 20789 demands
Compliances:• NEC Article 800 Type CMR (UL: 75˚C)• UL Style 2464 (UL: 80˚C, 300V)• CSA CMG (CSA: 60˚C)• Designed to meet UL 70,000 BTU Vertical
Tray Flame Test• Passes CSA CMG Flame Test
Packaging:• Please contact Customer Service for
packaging and color options
C0650C0651C0652C0653C0654C0655C0656C0658C0660C0663
2
3
4
5
6
7
8
10
12.5
25
22
22
22
22
22
22
22
22
22
22
7/30
7/30
7/30
7/30
7/30
7/30
7/30
7/30
7/30
7/30
0.010
0.010
0.010
0.010
0.010
0.010
0.010
0.010
0.010
0.010
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.032
0.032
0.032
0.032
0.032
0.032
0.032
0.032
0.032
0.058
0.81
0.81
0.81
0.81
0.81
0.81
0.81
0.81
0.81
0.81
0.229
0.296
0.320
0.322
0.348
0.348
0.368
0.440
0.455
0.620
5.82
7.52
8.13
8.18
8.84
8.84
9.35
11.18
11.56
15.75
16.6
16.6
16.6
16.6
16.6
16.6
16.6
16.6
16.6
16.6
3.8
4.1
3.5
3.9
4.4
5.0
3.8
4.1
4.7
2.1
33.2
28.6
28.6
28.6
26.2
26.2
26.2
26.2
26.2
26.2
59.7
51.5
51.5
51.5
47.2
47.2
47.2
47.2
47.2
46.0 *A - Capacitance between conductors*B - Capacitance between one conductor and other conductors connected to shield
Color Code Chart
123456789
101112
Single Conductor: Green with Yellow Stripe
NO. OFPAIRS COLOR
Black paired with RedBlack paired with WhiteBlack paired with GreenBlack paired with BlueBlack paired with YellowBlack paired with BrownBlack paired with OrangeRed paired with WhiteRed paired with GreenRed paired with BlueRed paired with YellowRed paired with Brown
NO. OFPAIRS COLOR
13141516171819202122232425
Red paired with OrangeWhite paired with GreenBlue paired with GreenYellow paired with GreenBrown paired with GreenOrange paired with GreenWhite paired with BlueWhite paired with YellowWhite paired with BrownWhite paired with OrangeYellow paired with BlueBlue paired with BrownOrange paired with Blue
47
Electronics Computer Cable
Multi-Paired, Foil/Braid Shield, Lo-Cap®
UL 2919, NEC Type CM (UL) c(UL) CMH
Product Construction:Conductor:• 24 AWG fully annealed stranded tinned
copper per ASTM B-33• Twisted pairs
Insulation:• Premium-grade, coIor-coded polyethylene• Color Code: See charts below
Shield:• 100% Flexfoil® aluminum/polyester
with 25% overlap, minimum, foil facing out• Stranded tinned copper drain wire• 90% tinned copper braid
Jacket:• PVC, gray• Temperature Range: – 20˚C to + 80˚C
Applications:• Computers• Industrial equipment• Data transmission• Control circuits• Low capacitance requirements• Suitable for EIA RS-485 applications• Suggested voltage rating: 30 volts
Features:• Braid shield provides good flexibility• Superior shielding where noise rejection
is critical• Assists system designers in meeting FCC
Docket 20789 demands
Compliances:• NEC Article 800 Type CM (UL: 75°C)• UL Style 2919 (UL: 80˚C, 30V)• Designed to meet UL 70,000 BTU Vertical
Tray Flame Test• CSA CMH (CSA: 60˚C)• Passes CSA CMH Flame Test
Packaging:• Please contact Customer Service for
packaging and color options
CATALOGNUMBER
C0841C0842C0843C0844
1
2
3
4
24
24
24
24
NO. OFPAIRS
AWGSIZE
7/32
7/32
7/32
7/32
COND.STRAND.
NOM.INSULATIONTHICKNESS
IN mm
0.024
0.024
0.024
0.024
0.61
0.61
0.61
0.61
NOM. JACKET
THICKNESSIN mm
0.032
0.032
0.032
0.032
0.81
0.81
0.81
0.81
NOMINALO.D.
IN mm
0.235
0.304
0.360
0.390
5.97
7.72
9.14
9.91
NOMINAL DCRΩ/kft
COND. SHLD.
25.7
25.7
25.7
25.7
2.9
2.3
2.3
2.1
VEL.OF
PROP.,%
NOM.IMP.,Ω
66
66
66
66
120
120
120
120
NOMINALCAP.*pF/ft
A B
14.6
11.7
11.9
11.9
26.2
21.0
21.4
21.4*A - Capacitance between conductors*B - Capacitance between one conductor and other conductors connected to shield
Color Code Chart 1
1234
NO. OFPAIRS COLOR
Black paired with RedBlack paired with WhiteBlack paired with GreenBlack paired with Blue
CATALOGNUMBER
C4841C4842C4843C4844
1
2
3
4
24
24
24
24
NO. OFPAIRS
AWGSIZE
7/32
7/32
7/32
7/32
COND.STRAND.
NOM.INSULATIONTHICKNESS
IN mm
0.024
0.024
0.024
0.024
0.61
0.61
0.61
0.61
NOM. JACKET
THICKNESSIN mm
0.032
0.032
0.032
0.032
0.81
0.81
0.81
0.81
NOMINALO.D.
IN mm
0.235
0.304
0.360
0.390
5.97
7.72
9.14
9.91
NOMINAL DCRΩ/kft
COND. SHLD.
25.7
25.7
25.7
25.7
2.9
2.3
2.3
2.1
VEL.OF
PROP.,%
NOM.IMP.,Ω
66
66
66
66
120
120
120
120
NOMINAL*CAP.pF/ft
A B
14.6
11.7
11.9
11.9
26.2
21.0
21.4
21.4*A - Capacitance between conductors*B - Capacitance between one conductor and other conductors connected to shield
Color Code Chart 2
1
2
NO. OFPAIRS COLOR
White—Blue StripeBlue—White StripeWhite—Orange StripeOrange—White Stripe
3
4
NO. OFPAIRS COLOR
White—Green StripeGreen—White StripeWhite—Brown StripeBrown—White Stripe
48
Computer Cable Electronics
Product Construction:Conductor:• 28 AWG fully annealed stranded tinned
copper per ASTM B-33• Twisted pairs
Insulation:• Premium-grade, coIor-coded polypropylene• Color Code: See chart below
Shield:• 100% Flexfoil® aluminum/polyester
with 25% overlap, minimum, foil facing out• Stranded tinned copper drain wire• 90% tinned copper braid
Jacket:• PVC, gray• Temperature Range: – 20°C to + 75°C
Applications:• Computers• Industrial equipment• Data transmission• Control circuits• Low capacitance requirements• Suitable for EIA RS-232 applications• Suitable for EIA RS-422 applications• Suggested voltage rating: 30 volts
Features:• Braid shield provides good flexibility• Superior shielding where noise rejection
is critical• Assists system designers in meeting FCC
Docket 20789 demands
Compliances:• NEC Article 725 Type CL2 (UL: 75°C)• UL Style 2960 (UL: 60°C, 30V)• Designed to meet UL 70,000 BTU Vertical
Tray Flame Test
Packaging:• Please contact Customer Service for
packaging and color options
Multi-Paired, Foil/Braid Shield, Lo-Cap®
UL 2960, NEC Type CL2
CATALOGNUMBER
C0804C0805C0806C0807C0808C0809C0810C0812
2
3
4
5
7
9
10
12
28
28
28
28
28
28
28
28
NO. OFPAIRS
AWGSIZE
7/36
7/36
7/36
7/36
7/36
7/36
7/36
7/36
COND.STRAND.
NOM.INSULATIONTHICKNESS
IN mm
0.009
0.009
0.009
0.009
0.009
0.009
0.009
0.009
0.23
0.23
0.23
0.23
0.23
0.23
0.23
0.23
NOM. JACKET
THICKNESSIN mm
0.032
0.032
0.032
0.032
0.032
0.032
0.032
0.032
0.81
0.81
0.81
0.81
0.81
0.81
0.81
0.81
NOMINALO.D.
IN mm
0.194
0.194
0.211
0.226
0.253
0.286
0.285
0.294
4.93
4.93
5.36
5.74
6.43
7.26
7.24
7.47
NOMINAL DCRΩ/kft
COND. SHLD.
67.5
67.5
67.5
67.5
67.5
67.5
67.5
67.5
4.0
4.2
3.3
3.5
2.9
2.9
2.9
3.3
VEL.OF
PROP.,%
NOM.IMP.,Ω
66
66
66
66
66
66
66
66
100
100
100
100
100
100
100
100
NOMINALCAP.*pF/ft
A B
14.8
14.0
14.0
14.0
13.1
13.1
13.1
13.1
26.6
25.3
25.3
25.3
23.5
23.5
23.5
23.5 *A - Capacitance between conductors*B - Capacitance between one conductor and other conductors connected to shield
Color Code Chart
123456
NO. OFPAIRS COLOR
Black paired with RedBlack paired with WhiteBlack paired with GreenBlack paired with BlueBlack paired with YellowBlack paired with Brown
NO. OFPAIRS COLOR
789
101112
Black paired with OrangeRed paired with WhiteRed paired with GreenRed paired with BlueRed paired with YellowRed paired with Brown
49
Electronics Computer Cable
Product Construction:Conductor:• 24 AWG fully annealed stranded tinned
copper per ASTM B-33• Twisted pairs
Insulation:• Premium-grade, coIor-coded polyethylene• Color Code: See chart below
Shield:• 100% Flexfoil® aluminum/polyester
with 25% overlap, minimum, foil facing out• Stranded tinned copper drain wire• 90% tinned copper braid
Jacket:• PVC, gray• Temperature Range: – 20˚C to + 80˚C
Applications:• Computers• Industrial equipment• Data transmission• Control circuits• Low capacitance requirements• Suitable for EIA RS-232 applications• Suitable for EIA RS-422 applications• Suggested voltage rating: 30 volts
Features:• Braid shield provides good flexibility• Superior shielding where noise rejection
is critical• Assists system designers in meeting FCC
Docket 20789 demands
Compliances:• NEC Article 800 Type CM (UL: 75˚C)• UL Style 2919 (UL: 80˚C, 30V)• Designed to meet UL 70,000 BTU Vertical
Tray Flame Test• CSA CMH (CSA: 60˚C)• Passes CSA CMH Flame Test
Packaging:• Please contact Customer Service for
packaging and color options
Multi-Paired, Foil/Braid Shield, Lo-Cap®
UL 2919, NEC Type CM (UL) c(UL) CMH
CATALOGNUMBER
C0829C0830C0831C0832C0839C0833C0835C0836
2
3
4
5
6
7
10
12
24
24
24
24
24
24
24
24
NO. OFPAIRS
AWGSIZE
7/32
7/32
7/32
7/32
7/32
7/32
7/32
7/32
COND.STRAND.
NOM.INSULATIONTHICKNESS
IN mm
0.015
0.015
0.015
0.015
0.015
0.015
0.015
0.015
0.38
0.38
0.38
0.38
0.38
0.38
0.38
0.38
NOM. JACKET
THICKNESSIN mm
0.032
0.032
0.032
0.032
0.032
0.032
0.038
0.038
0.81
0.81
0.81
0.81
0.81
0.81
0.97
0.97
NOMINALO.D.
IN mm
0.257
0.289
0.313
0.338
0.364
0.364
0.462
0.479
6.53
7.34
7.95
8.59
9.24
9.24
11.73
12.17
NOMINAL DCRΩ/kft
COND. SHLD.
25.7
25.7
25.7
25.7
25.7
25.7
25.7
25.7
2.7
2.6
3.2
1.9
2.4
2.0
1.7
1.8
VEL.OF
PROP.,%
NOM.IMP.,Ω
66
66
66
66
66
66
66
66
100
100
100
100
100
100
100
100
NOMINALCAP.*pF/ft
A B
14.8
14.2
14.2
14.2
13.2
13.2
13.2
13.2
26.7
25.5
25.5
25.5
23.8
23.8
23.8
23.8 *A - Capacitance between conductors*B - Capacitance between one conductor and other conductors connected to shield
Color Code Chart
123456
NO. OFPAIRS COLOR
Black paired with RedBlack paired with WhiteBlack paired with GreenBlack paired with BlueBlack paired with YellowBlack paired with Brown
NO. OFPAIRS COLOR
789
101112
Black paired with OrangeRed paired with WhiteRed paired with GreenRed paired with BlueRed paired with YellowRed paired with Brown
Product Construction:Conductor:• 24 AWG fully annealed stranded tinned
copper per ASTM B-33• Twisted pairs
Insulation:• Premium-grade, coIor-coded Lo-Cap®
foamed polypropylene• Color Code: See chart below
Shield:• 100% Flexfoil® aluminum/polyester
with 25% overlap, minimum, foil facing out• Stranded tinned copper drain wire• 65% tinned copper braid
Jacket:• PVC, gray• Temperature Range: – 20°C to + 80°C
Applications:• High-speed computer interconnects• CAD/CAM systems• EIA RS-232 and RS-423 systems• Control circuits• Industrial equipment• Low signal distortion data requirements• Suggested voltage rating: 30 volts
Features:• Braid shield provides good flexibility• Superior shielding where noise rejection
is critical• Assists system designers in meeting FCC
Docket 20789 demands
Compliances:• NEC Article 800 Type CM (UL: 75°C)• UL Style 2919 (UL: 80°C, 30V)• Designed to meet UL 70,000 BTU Vertical
Tray Flame Test• CSA CMH (CSA: 60˚C)• Passes CSA CMH Flame Test
Packaging:• Please contact Customer Service for
packaging and color options
CATALOGNUMBER
C0515C0516C0517C0518C0519C0520C0521C0522C0523C0524C0525C0526
2
3
4
5
6
7
8
10
12.5
15
18
25
24
24
24
24
24
24
24
24
24
24
24
24
NO. OFPAIRS
AWGSIZE
7/32
7/32
7/32
7/32
7/32
7/32
7/32
7/32
7/32
7/32
7/32
7/32
COND.STRAND.
NOM.INSULATIONTHICKNESS
IN mm
0.016
0.016
0.016
0.016
0.016
0.016
0.016
0.016
0.016
0.016
0.016
0.016
0.41
0.41
0.41
0.41
0.41
0.41
0.41
0.41
0.41
0.41
0.41
0.41
NOM. JACKET
THICKNESSIN mm
0.032
0.032
0.032
0.032
0.032
0.032
0.032
0.038
0.038
0.048
0.048
0.048
0.81
0.81
0.81
0.81
0.81
0.81
0.81
0.97
0.97
1.22
1.22
1.22
NOMINALO.D.
IN mm
0.276
0.290
0.315
0.340
0.368
0.370
0.397
0.473
0.486
0.555
0.585
0.677
7.01
7.37
8.00
8.64
9.35
9.40
10.08
12.01
12.34
14.10
14.86
17.20
NOMINAL DCRΩ/kft
COND. SHLD.
25.7
25.7
25.7
25.7
25.7
25.7
25.7
25.7
25.7
25.7
25.7
25.7
3.0
3.2
3.3
4.2
3.6
3.5
2.7
2.4
2.4
2.6
2.1
2.0
VEL.OF
PROP.,%
NOM.IMP.,Ω
78
78
78
78
78
78
78
78
78
78
78
78
132
132
132
132
141
141
141
141
141
141
141
141
NOMINALCAP.*pF/ft
A B
10.2
9.9
9.9
9.9
9.2
9.2
9.2
9.2
9.2
9.2
9.2
9.2
18.4
17.8
17.8
17.8
16.6
16.6
16.6
16.6
16.6
16.6
16.6
16.6*A - Capacitance between conductors*B - Capacitance between one conductor and other conductors connected to shield
Color Code Chart
1
2
3
4
5
6
7
8
9
NO. OFPAIRS COLOR
White—Blue StripeBlue—White StripeWhite—Orange StripeOrange—White StripeWhite—Green StripeGreen—White StripeWhite—Brown StripeBrown—White StripeWhite—Gray StripeGray—White StripeRed—Blue StripeBlue—Red StripeRed—Orange StripeOrange—Red StripeRed—Green StripeGreen—Red StripeRed—Brown StripeBrown—Red Stripe
10
11
12
13
14
15
16
17
NO. OFPAIRS COLOR
Red—Gray StripeGray—Red StripeBlack—Blue StripeBlue—Black StripeBlack—Orange StripeOrange—Black StripeBlack—Green StripeGreen—Black StripeBlack—Brown StripeBrown—Black StripeBlack—Gray StripeGray—Black StripeYellow—Blue StripeBlue—Yellow StripeYellow—Orange StripeOrange—Yellow Stripe
18
19
20
21
22
23
24
25
NO. OFPAIRS COLOR
Yellow—Green StripeGreen—Yellow StripeYellow—Brown StripeBrown—Yellow StripeYellow—Gray StripeGray—Yellow StripeViolet—Blue StripeBlue—Violet StripeViolet—Orange StripeOrange—Violet StripeViolet—Green StripeGreen—Violet StripeViolet—Brown StripeBrown—Violet StripeViolet—Gray StripeGray—Violet Stripe
Single Conductor: Green with Yellow Stripe
50
Computer Cable Electronics
Multi-Paired, Foil/Braid Shield, Lo-Cap®
UL 2919, NEC Type CM (UL) c(UL) CMH
51
Electronics Computer Cable
Multi-Paired, Individually Foil ShieldedUL 2919, NEC Type CM, CSA CMH
Product Construction:Conductor:• 24 thru 18 AWG fully annealed stranded
tinned copper per ASTM B-33• Twisted pairs
Insulation:• Premium grade color coded polyethylene• Color Code: See chart below
Shield:• Individually shielded pairs• 100% Flexfoil® aluminum/polyester
with 25% overlap, minimum, foil facing in • Stranded tinned copper drain wire each pair
Jacket:• PVC, gray• Temperature Range: – 20˚C to + 80˚C
Applications:• Applications for total isolation of signal• Computers• Control circuits• Industrial equipment• Suggested voltage rating: 30 volts
Features:• Individually shielded pairs for excellent
signal isolation• Excellent high frequency properties• Mechanical durability
Compliances:• NEC Article 800 Type CM (UL: 75°C)• UL Style 2919 (UL: 80˚C, 30V)• CSA CMH (CSA: 60˚C)• Designed to Meet UL 70,000 BTU Vertical
Tray Flame Test• Passes CSA CMH Flame Test
Packaging:• Please contact Customer Service for
packaging and color options
CATALOGNUMBER
C6065C6066C6067C6040C6041C6042C6043C6059C6044C6060C6045C6046*C6052C6053C6054C6056C6058C6047C6048C6049C6050C6051
3
6
9
3
6
9
11
12
15
17
19
27
3
6
9
12
15
3
6
9
12
15
24
24
24
22
22
22
22
22
22
22
22
22
20
20
20
20
20
18
18
18
18
18
NO. OFPAIRS
AWGSIZE
7/32
7/32
7/32
7/30
7/30
7/30
7/30
7/30
7/30
7/30
7/30
7/30
7/28
7/28
7/28
7/28
7/28
16/30
16/30
16/30
16/30
16/30
COND.STRAND.
NOM.INSULATIONTHICKNESS
IN mm
0.011
0.011
0.011
0.011
0.011
0.011
0.011
0.011
0.011
0.011
0.011
0.011
0.013
0.013
0.013
0.013
0.013
0.016
0.016
0.016
0.016
0.016
0.28
0.28
0.28
0.28
0.28
0.28
0.28
0.28
0.28
0.28
0.28
0.28
0.33
0.33
0.33
0.33
0.33
0.41
0.41
0.41
0.41
0.41
NOM. JACKET
THICKNESSIN mm
0.032
0.032
0.032
0.032
0.032
0.032
0.032
0.048
0.048
0.048
0.048
0.048
0.032
0.032
0.048
0.048
0.048
0.032
0.048
0.048
0.048
0.048
0.81
0.81
0.81
0.81
0.81
0.81
0.81
1.22
1.22
1.22
1.22
1.22
0.81
0.81
1.22
1.22
1.22
0.81
1.22
1.22
1.22
1.22
NOMINALO.D.
IN mm
0.269
0.349
0.406
0.292
0.381
0.445
0.486
0.533
0.591
0.622
0.622
0.696
0.339
0.446
0.555
0.623
0.692
0.395
0.556
0.649
0.731
0.776
6.83
8.86
10.31
7.42
9.68
11.30
12.34
13.54
15.01
15.80
15.80
17.68
8.61
11.33
14.10
15.82
17.58
10.03
14.12
16.48
18.57
19.71
NOMINAL DCRΩ/kft
COND. SHLD.
26.0
26.0
26.0
15.0
15.0
15.0
15.0
15.0
15.0
15.0
15.0
15.0
10.5
10.5
10.5
10.5
10.5
6.4
6.4
6.4
6.4
6.4
18.0
18.0
18.0
11.3
11.3
11.3
11.3
11.3
11.3
11.3
11.3
11.3
10.2
10.2
10.2
10.2
10.2
8.3
8.3
8.3
8.3
8.3
VEL.OF
PROP.,%
NOM.IMP.,Ω
66
66
66
66
66
66
66
66
66
66
66
66
66
66
66
66
66
66
66
66
66
66
71
71
71
63
63
63
63
63
63
63
63
63
61
61
61
61
61
60
60
60
60
60
NOMINALCAP.**pF/ft
A B
21.7
21.7
21.7
24.4
24.4
24.4
24.4
24.4
24.4
24.4
24.4
24.4
25.3
25.3
25.3
25.3
25.3
25.7
25.7
25.7
25.7
25.7
39.0
39.0
39.0
43.9
43.9
43.9
43.9
43.9
43.9
43.9
43.9
43.9
45.6
45.6
45.6
45.6
45.6
46.2
46.2
46.2
46.2
46.2* UL2919, CSA CMH Only**A - Capacitance between conductors**B - Capacitance between one conductor and other conductors connected to shield
Color Code Chart
123456789
NO. OFPAIRS COLOR
Black paired with RedBlack paired with WhiteBlack paired with GreenBlack paired with BlueBlack paired with YellowBlack paired with BrownBlack paired with OrangeRed paired with WhiteRed paired with Green
NO. OFPAIRS COLOR
NO. OFPAIRS COLOR
101112131415161718
192021222324252627
Red paired with BlueRed paired with YellowRed paired with BrownRed paired with OrangeGreen paired with WhiteGreen paired with BlueGreen paired with YellowGreen paired with BrownGreen paired with Orange
White paired with BlueWhite paired with YellowWhite paired with BrownWhite paired with OrangeBlue paired with YellowBlue paired with BrownBlue paired with OrangeBrown paired with YellowBrown paired with Orange
52
Computer Cable Electronics
Multi-Paired, Individually Foil ShieldedNEC Type CL2 and CM (UL) c(UL)
Product Construction:Conductor:• 20 AWG fully annealed stranded tinned
copper per ASTM B-33• Twisted pairs
Insulation:• Premium grade color coded polypropylene• Color Code: See chart below
Shield:• Individually shielded pairs• 100% Flexfoil® aluminum/polyester
with 25% overlap, minimum, foil facing in • Stranded tinned copper drain wire each pair
Jacket:• PVC, gray• Temperature range: – 20˚C to + 75°C
Applications:• Applications for total isolation of signal • Computers• Control circuits• Industrial equipment• Suggested voltage rating: 300 volts
Features:• Individually shielded pairs for excellent
signal isolation• Excellent high frequency properties• Mechanical durability
Compliances:• NEC Article 725 Type CL2 (UL: 75°C, 150V)• NEC Article 800 Type CM (UL: 75°C, 300V)• Designed to Meet UL 70,000 BTU Vertical
Tray Flame Test
Packaging:• Please contact Customer Service for
packaging and color options
CATALOGNUMBER
NO. OFPAIRS
AWGSIZE
COND.STRAND.
NOM. INSULATIONTHICKNESS
INCHES mm
NOM. JACKETTHICKNESS
INCHES mm
NOMINALO.D.
NOMINAL CAP.*pF/ft
A BINCHES mm
C1368 4 20 7/28 0.015 0.38 0.81 0.364 41.523.09.250.032*A - Capacitance between conductors*B - Capacitance between one conductor and other conductors connected to shield
Color Code Chart
1234
NO. OFPAIRS COLOR
Red paired with White/RedBlack paired with White/BlackGreen paired with White/GreenWhite paired with White/Yellow
53
Electronics Computer Cable
C6035C6036
Product Construction:Conductor:• 22 AWG fully annealed solid tinned copper
per ASTM B-33• Twisted pairs
Insulation:• Premium-grade, coIor-coded PVC• Color Code: See chart below
Shield:• Individually shielded pairs• 100% Flexfoil® aluminum/polyester
with 25% overlap, minimum, foil facing in• Solid tinned copper drain wire each pair
Jacket:• PVC, gray• Temperature range: – 20˚C to + 80˚C
Applications:• Applications for total isolation of signal• Computers• Control circuits• Industrial equipment• Suggested voltage rating: 300 volts
Features:• Individually shielded pairs for excellent
signal isolation• Excellent high-frequency properties• Mechanical durability
Compliances:• NEC Article 800 Type CM (UL: 75˚C)• UL Style 2464 (UL: 80˚C, 300V)• CSA CMG (CSA: 60˚C)• Designed to meet UL 70,000 BTU Vertical
Tray Flame Test• Passes CSA CMG Flame Test
Packaging:• Please contact Customer Service for
packaging and color options
Multi-Paired, Individually Foil ShieldedUL 2464, NEC Type CM (UL) c(UL), CSA CMG
CATALOGNUMBER
3
6
22
22
NO. OFPAIRS
AWGSIZE
Solid
Solid
COND.STRAND.
NOM.INSULATIONTHICKNESS
IN mm
0.015
0.015
0.38
0.38
NOM. JACKET
THICKNESSIN mm
0.032
0.032
0.81
0.81
NOMINALO.D.
IN mm
0.304
0.397
7.72
10.08
NOMINAL DCRΩ/kft
COND. SHLD.
16.5
16.5
11.3
11.3
NOMINALIMPEDANCE
Ω
50
50
NOMINALCAP.*pF/ft
A B
38.6
38.6
69.4
69.4
Color Code Chart
123
NO. OFPAIRS COLOR
Black paired with RedBlack paired with WhiteBlack paired with Green
NO. OFPAIRS COLOR
456
Black paired with BlueBlack paired with YellowBlack paired with Brown
*A - Capacitance between conductors*B - Capacitance between one conductor and other conductors connected to shield
Product Construction:Conductor:• 24 AWG fully annealed stranded tinned
copper per ASTM B-33• Twisted pairs
Insulation:• Premium-grade, coIor-coded foamed
Lo-Cap® polypropylene• Color Code: See chart below
Shield:• Individually shielded pairs• 100% Flexfoil® aluminum/polyester
with 25% overlap, minimum, foil facing in • Stranded tinned copper drain wire each pair
Jacket:• PVC, gray• Temperature Range: – 20˚C to + 60˚C
Applications:• High-speed computers• Industrial equipment• Control circuits• Suitable for low capacitance applications• Suitable for EIA RS-422 CAD/CAM
applications• Suggested voltage rating: 300 volts
Features:• Individually shielded pairs for excellent
signal isolation• Excellent high-frequency properties• Mechanical durability
Compliances:• NEC Article 800 Type CM (UL: 75˚C, 300V)• UL Style 2493 (UL: 60˚C)• Designed to meet UL 70,000 BTU Vertical
Tray Flame Test• CSA CMH (CSA: 60˚C)• Passes CSA CMH Flame Test
Packaging:• Please contact Customer Service for
packaging and color options
C0910C0911C0912C0913C0914C0915C0916C0917
CATALOGNUMBER
2
3
4
6
9
11
12
15
24
24
24
24
24
24
24
24
NO. OFPAIRS
AWGSIZE
7/32
7/32
7/32
7/32
7/32
7/32
7/32
7/32
COND.STRAND.
NOM.INSULATIONTHICKNESS
IN mm
0.022
0.022
0.022
0.022
0.022
0.022
0.022
0.022
0.56
0.56
0.56
0.56
0.56
0.56
0.56
0.56
NOM. JACKET
THICKNESSIN mm
0.047
0.048
0.048
0.048
0.063
0.063
0.063
0.063
1.19
1.22
1.22
1.22
1.60
1.60
1.60
1.60
NOMINALO.D.
IN mm
0.283
0.381
0.416
0.492
0.601
0.652
0.672
0.743
7.19
9.68
10.57
12.50
15.27
16.56
17.08
18.87
NOMINAL DCRΩ/kft
COND. SHLD.
26.0
26.0
26.0
26.0
26.0
26.0
26.0
26.0
18.0
18.0
18.0
18.0
18.0
18.0
18.0
18.0
VEL.OF
PROP.,%
78
78
78
78
78
78
78
78
NOM.IMP.,Ω
100
100
100
100
100
100
100
100
NOMINALCAP.*pF/ft
A B
14.8
14.8
14.8
14.8
14.8
14.8
14.8
14.8
26.7
26.7
26.7
26.7
26.7
26.7
26.7
26.7 *A - Capacitance between conductors*B - Capacitance between one conductor and other conductors connected to shield
Color Code Chart
12345678
NO. OFPAIRS COLOR
Black paired with RedBlack paired with WhiteBlack paired with GreenBlack paired with BlueBlack paired with YellowBlack paired with BrownBlack paired with OrangeRed paired with White
9101112131415
NO. OFPAIRS COLOR
Red paired with GreenRed paired with BlueRed paired with YellowRed paired with BrownRed paired with OrangeGreen paired with WhiteGreen paired with Blue
54
Computer Cable Electronics
Multi-Paired, Individually Foil Shielded, Lo-Cap®
UL 2493, NEC Type CM (UL) c(UL) CMH
55
Electronics Computer Cable
Multi-Paired, Individually Foil/Braid Shielded, Lo-Cap®
UL 2493, NEC Type CM (UL) c(UL) CMH
Product Construction:Conductor:• 24 AWG fully annealed stranded tinned
copper per ASTM B-33• Twisted pairs
Insulation:• Premium-grade, coIor-coded foamed
Lo-Cap® polypropylene• Color Code: See chart below
Shield:• Individually shielded pairs• 100% Flexfoil® aluminum/polyester
with 25% overlap, minimum, foil facing in • Stranded tinned copper drain wire, each pair• 70% tinned copper braid, each pair
Jacket:• PVC, gray• Temperature Range: – 20˚C to + 75˚C
Applications:• High-speed computers• Industrial equipment• Control circuits• Designed for low capacitance applications• Suitable for RS-422 CAD/CAM applications• Suggested voltage rating: 300 volts
Features:• Individually shielded pairs for excellent
signal isolation• Excellent high-frequency properties• Mechanical durability
Compliances:• NEC Article 800 Type CM (UL: 75˚C, 300V)• UL Style 2493 (UL: 60˚C)• Designed to meet UL 70,000 BTU Vertical
Tray Flame Test• CSA CMH (CSA: 60˚C)• Passes CSA CMH Flame Test
Packaging:• Please contact Customer Service for
packaging and color options
C0924C0925C0926
CATALOGNUMBER
2
3
4
24
24
24
NO. OF
PAIRSAWGSIZE
7/32
7/32
7/32
COND.STRAND.
NOM.INSULATIONTHICKNESS
IN mm
0.022
0.022
0.022
0.56
0.56
0.56
NOM. JACKET
THICKNESSIN mm
0.048
0.048
0.048
1.22
1.22
1.22
NOMINALO.D.
IN mm
0.390
0.410
0.445
9.91
10.41
11.30
NOMINAL DCR**Ω/kft
C
26.0
26.0
26.0
D
18.0
18.0
18.0
E
4.3
4.4
3.2
VEL.OF
PROP.,%
78
78
78
NOM.IMP.,Ω
100
100
100
NOMINALCAP.*pF/ft
A B
14.8
14.8
14.8
26.7
26.7
26.7 *A - Capacitance between conductors*B - Capacitance between one conductor and other conductors connected to shield**C - Conductor resistance**D - Individual shield resistance**E - Overall shield resistance
Color Code Chart
1234
NO. OFPAIRS COLOR
Black paired with RedBlack paired with WhiteBlack paired with GreenBlack paired with Blue
56
Electronics
Coaxial Cable 5
Index Page
Carol® Brand Coaxial
RG 6/U Type 57-60
RG 7/U Type 61
RG 8/U Type 62
RG 11/U Type 63-64
RG 58/U Type 65
RG 59/U Type 66-69
RG 62/U Type 70
RG 174/U Type & RG 213/U Type 71
Other Coaxial Cables 72
Twinaxial Cables 73
Helix/HiTemp™ Brand Coaxial
RG 6 & RG 11 BroadbandQuad Shield Cable 75RG 8/U Type Cable 76RG 8/U Type Thicknet/ Trunk Cable 77RG 58/U Type Cable 78-79RG 58/U Type Thinnet Cable 80Headend CATV Drop Cable 81Headend Tinned Copper Drop Cable 82RG 213, RG 214, RG 174 Cable 83
To meet the needs of today’ssophisticated, high-speed,wide bandwidth electronicsover long distances, withminimum signal loss ordegradation, General CableCarol® and Helix/HiTemp™
Brands offers a wide range ofcoaxial and twinaxial designsin both unbalanced arrays andprecision balanced pairs. Thisoffers the system designer awide choice of cost-effectiveproducts that reflect the mostrecent changes in thestandards set by UL, CSA and/or the FCC.
Included in this section arerecommended Carol® Brandcoaxial products for the CATVmarket. However, theseconstructions may differ incertain parts of the country.
Unlike other products in theelectronic market, coaxial cabledoes not have one accepted
standard construction.General Cable recommends,
in order to avoid installing anunacceptable coaxial cable forthe CATV application in yourarea, the local CATV companyshould be consulted.
General Cable’s Carol® Brandproduct mix encompassesstandard RG/U-type coaxialconstructions in the morepopular 50, 75 and 93 ohmdesigns and miniature coaxialproducts for smaller high-speed applications.
The twinaxial products meetor exceed the stringentdemands of today’s precisionbalanced pair systems. Theminimization of capacitanceunbalance is a necessaryrequirement for long distancedata transmission.
57
Electronics Coaxial Cable
RG 6/U Type
Product Construction:Conductors:
• Copper per ASTM B-3• Copper-clad steel per ASTM B-869
Insulation/Core:• Cellular polyethylene
Shield:• Bare copper or aluminum braid• Flexfoil® shield
Jacket:• Premium PVC compound
Packaging:• Please contact Customer Service for
packaging and color options
Applications:• Suitable for RF signal transmission• MATV• CATV• CCTV• Local Area Network• Drop cable• FM broadcast• See Coax Connector Cross Reference,
pages 188-195
C5760RG 6/U Type
C5761RG 6/U TypeCCTVUL CL2, CATV, CMC(UL) CM
C5774RG 6/U TypeUL CL2, CATV, CMC(UL) CM
C5775RG 6/U TypeUL CL2, CATV, CMC(UL) CM
C5886RG 6/U Type RiserUL CL2R, CATVR, CMRC(UL) CMR
C5776RG 6/U TypeUL CL2, CATV, CMC(UL) CM
CATALOGNUMBER
AWG SIZE
NOM. DCR
INSULATIONMATERIAL
INCHES mm
SHIELD COVERAGE
NOM SHLD DCR
NOMINAL O.D.
NOMINALATTENUATION
VELOCITY OFPROPAGATION,
%
NOMINALIMPEDANCE,
Ω MHz dB/100'
NOMINALCAPACITANCEpF/ft pF/mINCHES mm
18 Ga.Solid
Copper-Clad Steel28.9 V/M
18 Ga.Solid Bare
Copper6.5 V/M
18 Ga.Solid
Copper-Clad Steel28.9 V/M
18 Ga.Solid
Copper-Clad Steel28.9 V/M
18 Ga.Solid
Copper-Clad Steel28.9 V/M
18 Ga.Solid
Copper-Clad Steel28.9 V/M
CellularPolyethylene
CellularPolyethylene
CellularPolyethylene
CellularPolyethylene
CellularPolyethylene
CellularPolyethylene
0.180
0.180
0.177
0.177
0.177
0.177
4.57
4.57
4.50
4.50
4.50
4.50
100% Flexfoil®30 Ga. CCS
Spiral ServedShield
30.0 V/M
100% Flexfoil®+95%
Bare CopperBraid
2.6 V/M
100% Flexfoil®Bonded+40%
Aluminum Braid10.5 V/M
100% Flexfoil®Bonded+60%
Aluminum Braid9.0 V/M
100% Flexfoil®Bonded+60%
Aluminum Braid9.0 V/M
100% Flexfoil®Bonded+95%
Aluminum Braid10.5 V/M
85
85
85
85
85
85
75
75
75
75
75
75
11050
100200500
1000
11050
100200500
1000
11050
100200500
10001450180022003000
11050
100200500
10001450180022003000
11050
100200500
10001450180022003000
11050
100200500
10001450180022003000
0.260.811.462.052.834.536.59
0.260.811.462.052.834.536.59
0.260.811.462.052.834.536.598.108.80
10.1011.79
0.260.811.462.052.834.536.598.108.80
10.1011.79
0.260.811.462.052.834.536.598.108.80
10.1011.79
0.260.811.462.052.834.536.598.108.80
10.1011.79
16.20
16.20
16.20
16.20
16.20
16.20
53.15
53.15
53.15
53.15
53.15
53.15
Black PVC
Black PVC
Black PVC
Black PVC
Black PVC
Black PVC
0.240
0.270
0.267
0.263
0.263
0.267
6.10
6.86
6.78
6.68
6.68
6.78
58
Coaxial Cable Electronics
C5888RG 6/U Type RiserUL CL2R, CATVR, CMRC(UL) CMR
C5785RG 6/U TypeQuad-ShieldUL CL2, CATV, CMC(UL) CM
C5889RG 6/U Type RiserQuad-ShieldUL CL2R, CATVR, CMRC(UL) CMR
C5777RG 6/U TypeUL CL2, CATV, CMC(UL) CM
C5802RG 6/U TypeMessengered,Self-Supporting
Figure 8. Contains 0.051" galvanized steel messenger wire.
C5804RG 6/U TypeMoistureGuard™Direct Burial, Flooded
C5810RG 6/U TypeSpecial ApplicationsMATV Cable
RG 6/U Type
Product Construction:Conductors:
• Copper per ASTM B-3• Copper-clad steel per ASTM B-869
Insulation/Core:• Solid and cellular polyethylene designs
Shield:• Tinned, bare copper or aluminum braid• Flexfoil® shield
Jacket:• Premium PVC compound or
PE compound
Packaging:• Please contact Customer Service for
packaging and color options
Applications:• CATV• MATV• LAN cable• Digital video• Direct burial• See Coax Connector Cross Reference,
pages 188-195
CATALOGNUMBER
AWG SIZE
NOM. DCR
INSULATIONMATERIAL
INCHES mm
SHIELD COVERAGE
NOM SHLD DCR
NOMINAL O.D.
NOMINALATTENUATION
VELOCITY OFPROPAGATION,
%
NOMINALIMPEDANCE,
Ω MHz dB/100'
NOMINALCAPACITANCEpF/ft pF/mINCHES mm
18 Ga.Solid
Copper-Clad Steel28.9 V/M
18 Ga.Solid
Copper-Clad Steel28.9 V/M
18 Ga.Solid
Copper-Clad Steel28.9 V/M
18 Ga.Solid
Copper-Clad Steel28.9 V/M
18 Ga.Solid
Copper-Clad Steel28.9 V/M
18 Ga.Solid
Copper-Clad Steel28.9 V/M
21 Ga.Solid
Copper-Clad Steel32.0 V/M
CellularPolyethylene
CellularPolyethylene
CellularPolyethylene
CellularPolyethylene
CellularPolyethylene
CellularPolyethylene
SolidPolyethylene
0.177
0.177
0.177
0.177
0.180
0.180
0.185
4.50
4.50
4.50
4.50
4.57
4.57
4.70
100% Flexfoil®Bonded+95%
AluminumBraid
6.5 V/M
(2) 100% Flexfoil®1st Bonded
(1) 60%(2) 40%
Aluminum Braids3.7 V/M
(2) 100% Flexfoil®1st Bonded
(1) 60%(2) 40%
Aluminum Braids3.7 V/M
100% Flexfoil®Bonded+61%
Tinned CopperBraid
6.5 V/M
100% Flexfoil®Bonded+60%
Aluminum Braid9.0 V/M
100% Flexfoil®Bonded+60%
Aluminum Braidw/ water block
9.0 V/M
(2) Bare Copper95% Braids
1.1 V/M
85
85
85
85
85
85
66
75
75
75
75
75
75
75
11050
100200500
10001450180022003000
11050
100200500
10001450180022003000
11050
100200500
10001450180022003000
11050
100200500
10001450180022003000
11050
100200500
1000
11050
100200500
1000
11050
100200500
1000
0.260.811.462.052.834.536.598.108.80
10.1011.79
0.260.811.462.052.834.536.598.108.80
10.1011.79
0.260.811.462.052.834.536.598.108.80
10.1011.79
0.260.811.462.052.834.536.598.108.80
10.1011.79
0.260.811.462.052.834.536.59
0.260.811.462.052.834.536.59
0.400.801.902.704.106.609.80
16.20
16.20
16.20
16.20
16.20
16.20
20.50
53.15
53.15
53.15
53.15
53.15
53.15
67.26
Black PVC
Black PVC
Black PVC
Black PVC
Black PVC
Black PE
Black PE
0.267
0.292
0.292
0.267
0.270X
0.428
0.270
0.332
6.78
7.42
7.42
6.78
6.86X
10.87
6.86
8.43
FlexFill®
59
Electronics Coaxial Cable
C5812RG 6/U TypeLAN CableIEEE 802.4 MAP TypeUL CL2, CATV, CMC(UL) CM
C5814RG 6/U TypeDigital VideoUL CL2, CATV, CMC(UL) CM
C5822RG 6/U Dual-TypeDBSUL CL2, CATV, CMC(UL) CM
C5890RG 6/U Dual-TypeDBS RiserUL CL2R, CATVR, CMRC(UL) CMR
C5824RG 6/U TypeDBS w/GroundUL CL2, CATV, CMC(UL) CM
Contains 17 AWG ( .045")CCS ground wire.
C5826RG 6/U Dual-TypeDBS w/ GroundUL CL2, CATV, CMC(UL) CM
Contains 17 AWG ( .045") CCS ground wire.
RG 6/U Type
Product Construction:Conductors:
• Copper per ASTM B-3• Copper-clad steel per ASTM B-869
Insulation/Core:• Cellular polyethylene
Shield:• Tinned copper or aluminum braid• Flexfoil® shield
Jacket:• Premium PVC compound
Packaging:• Please contact Customer Service for
packaging and color options
Applications:• LAN cable• Digital video• Direct broadcast satellite• See Coax Connector Cross Reference,
pages 188-195
CATALOGNUMBER
AWG SIZE
NOM. DCR
INSULATIONMATERIAL
INCHES mm
SHIELD COVERAGE
NOM SHLD DCR
NOMINAL O.D.
NOMINALATTENUATION
VELOCITY OFPROPAGATION,
%
NOMINALIMPEDANCE,
Ω MHz dB/100'
NOMINALCAPACITANCEpF/ft pF/mINCHES mm
18 Ga.Solid
Copper-Clad Steel28.9 V/M
18 Ga.Solid Bare
Copper6.5 V/M
18 Ga.Solid
Copper-Clad Steel28.9 V/M
18 Ga.Solid
Copper-Clad Steel28.9 V/M
18 Ga.Solid Bare
Copper6.5 V/M
18 Ga.Solid Bare
Copper6.5 V/M
CellularPolyethylene
CellularPolyethylene
CellularPolyethylene
CellularPolyethylene
CellularPolyethylene
CellularPolyethylene
0.177
0.180
0.180
0.180
0.180
0.180
4.50
4.57
4.57
4.57
4.57
4.57
85
85
85
85
85
85
100% Flexfoil®Bonded+77%
Aluminum Braid+100% Flexfoil®
5.4 V/M
100% Flexfoil®+95%
Tinned CopperBraid
2.7 V/M
100% Flexfoil®Bonded+60%
Aluminum Braid9.0 V/M
100% Flexfoil®Bonded+60%
Aluminum Braid9.0 V/M
100% Flexfoil®Bonded+60%
Aluminum Braid9.0 V/M
100% Flexfoil®Bonded+60%
Aluminum Braid9.0 V/M
75
75
75
75
75
75
11050
100200500
1000
11050
100200500
10001450180022003000
11050
100200500
10001450180022003000
11050
100200500
10001450180022003000
11050
100200500
10001450180022003000
11050
100200500
10001450180022003000
0.260.811.462.052.834.536.59
0.200.721.482.012.794.466.537.868.769.69
11.31
0.260.811.462.052.834.536.598.108.80
10.1011.79
0.260.811.462.052.834.536.598.108.80
10.1011.79
0.260.811.462.052.834.536.598.108.80
10.1011.79
0.260.811.462.052.834.536.598.108.80
10.1011.79
16.20
16.20
16.20
16.20
16.20
16.20
53.15
53.15
53.15
53.15
53.15
53.15
Black PVC
Black PVC
Black PVC
Black PVC
Black PVC
Black PVC
0.290
0.270
0.267X
0.595
0.270X
0.595
0.270X
0.410
0.270X
0.720
7.37
6.86
6.86X
15.11
6.86X
10.41
6.86X
10.41
6.86X
17.86
60
Coaxial Cable Electronics
RG 6/U Type
Product Construction:Conductors:
• Copper per ASTM B-3or copper-clad steel per ASTM B-869
Insulation/Core:• Cellular polyethylene design• Cellular fluoropolymer designs
Shield:• Tinned copper or aluminum braid• Flexfoil® shield
Jacket:• Premium-grade PVC compound
Packaging:• Please contact Customer Service for
packaging and color options
Applications:• Suitable for RF signal transmission• CATV• DBS• Drop cable• FM broadcast• Digital Video• See Coax Connector Cross Reference,
pages 188-195
C5778RG 6/U TypeUL CL2, CATV, CMC(UL) CM
C3523RG 6/U TypePlenumUL CL2P, CMPC(UL) CMP
C3521RG 6/U TypePlenumUL CL2P, CMPC(UL) CMP
C3524RG 6/U TypePlenumUL CL2P, CMPC(UL) CMP
C3525RG 6/U TypeQuad-ShieldPlenumUL CL2P, CMPC(UL) CMP
C8029RG 6/U Type+18 AWG Unshielded PairUL CL2, CATV, CMC(UL) CM
C8031RG 6/U Type+18 AWG Unshielded PairUL CMPC(UL) CMP
CATALOGNUMBER
AWG SIZE
NOM. DCR
INSULATIONMATERIAL
INCHES mm
SHIELD COVERAGE
NOM SHLD DCR
NOMINAL O.D.
NOMINALATTENUATION
VELOCITY OFPROPAGATION,
%
NOMINALIMPEDANCE,
Ω MHz dB/100'
NOMINALCAPACITANCEpF/ft pF/mINCHES mm
18 Ga.Solid Bare
Copper6.5 V/M
18 Ga.Solid Bare
Copper6.5 V/M
18 Ga.Solid Bare
Copper6.5 V/M
18 Ga.Solid
Copper-Clad Steel6.5 V/M
18 Ga.Solid
Copper-Clad Steel6.5 V/M
18 Ga.Solid BC
Coax
18 AWG 7/26Unshielded Pair
18 AWGSolid BC
Coax
18 AWG 7/26Unshielded Pair
CellularPolyethylene
CellularFluoropolymer
CellularFluoropolymer
CellularFluoropolymer
CellularFluoropolymer
CellularPolyethylene
Premium PVC
CellularFEP
Halar
0.177
0.170
0.170
0.170
0.170
0.177
0.010
0.170
0.006
4.50
4.32
4.32
4.32
4.32
4.50
0.25
0.432
0.15
100% Flexfoil®Bonded+61%
Tinned CopperBraid
6.5 V/M
100% Flexfoil®+61%
Tinned CopperBraid
2.3 V/M
100% Flexfoil®95%
Tinned CopperBraid
2.3 V/M
100% Flexfoil®+60%
Aluminum Braid9.0 V/M
(2) 100% Flexfoil®1st Bonded
(1) 60%(2) 40%
Aluminum Braids5.3 V/M
100% Flexfoil®+95% Bare
Copper Braid
Unshielded Pair
95% Bare CopperBraid
Unshielded Pair
85
86
86
86
86
85
86
75
75
75
75
75
75
75
11050
100200500
10001450180022003000
11050
100200500
1000
11050
100200500
1000
11050
100200500
10002300
11050
100200500
10002300
11050
100200500100
11050
100200500
1000
0.260.811.462.052.834.536.598.108.80
10.1011.79
0.300.661.502.103.105.007.30
0.300.661.502.103.105.007.30
0.300.661.502.103.105.007.30
12.20
0.300.661.502.103.105.007.30
12.20
0.200.721.482.012.704.466.53
0.300.661.502.103.105.007.30
16.20
16.40
16.00
16.00
16.00
16.20
16.30
53.15
52.50
52.50
52.50
52.50
53.15
53.48
Black PVC
Flexguard®
Natural
Flexguard®
Natural
Flexguard®
Natural
Flexguard®
Natural
Black PVC
Natural PVC
0.267
0.226
0.233
0.226
0.226
0.270X
0.493
0.232X
0.416
6.78
5.74
5.92
5.74
5.74
6.86X
12.52
5.89X
10.57
61
Electronics Coaxial Cable
RG 7/U Type
Product Construction:Conductors:
• Copper-clad steel per ASTM B-869Insulation/Core:
• Cellular polyethyleneShield:
• Aluminum braid• Flexfoil® shield
Jacket:• Premium-grade PVC compound or
PE compound
Packaging:• Please contact Customer Service for
packaging and color options
Applications:• Suitable for RF signal transmission• MATV• CATV• Local Area Network• Drop cable• FM broadcast• Direct burial• See Coax Connector Cross Reference,
pages 188-195
C5851RG 7/U TypeUL CL2, CATV, CMC(UL) CM
C5853RG 7/U TypeMoistureGuard™Direct Burial, Flooded
C5856RG 7/U TypeTri-ShieldUL CL2, CATV, CMC(UL) CM
C5857RG 7/U TypeQuad-ShieldUL CL2, CATV, CMC(UL) CM
CATALOGNUMBER
AWG SIZE
NOM. DCR
INSULATIONMATERIAL
INCHES mm
SHIELD COVERAGE
NOM SHLD DCR
NOMINAL O.D.
NOMINALATTENUATION
VELOCITY OFPROPAGATION,
%
NOMINALIMPEDANCE,
Ω MHz dB/100'
NOMINALCAPACITANCEpF/ft pF/mINCHES mm
16 Ga.Solid
Copper-Clad Steel18.2 V/M
16 Ga.Solid
Copper-Clad Steel18.2 V/M
16 Ga.Solid
Copper-Clad Steel18.2 V/M
16 Ga.Solid
Copper-Clad Steel18.2 V/M
CellularPolyethylene
CellularPolyethylene
CellularPolyethylene
CellularPolyethylene
0.225
0.225
0.225
0.225
5.72
5.72
5.72
5.72
100% Flexfoil®Bonded+61%
Aluminum Braid5.6 V/M
100% Flexfoil®Bonded+61%
Aluminum Braidw/ water block
5.6 V/M
100% Flexfoil®Bonded+61%
Aluminum Braid+100% Flexfoil®
4.5 V/M
(2) 100% Flexfoil®1st Bonded
(1) 60%(2) 40%
Aluminum Braids3.4 V/M
85
85
85
85
75
75
75
75
11050
100200500
1000
11050
100200500
1000
11050
100200500
1000
11050
100200500
1000
0.350.771.121.592.283.675.26
0.350.771.121.592.283.675.26
0.350.771.121.592.283.675.26
0.350.771.121.592.283.675.26
16.20
16.20
16.20
16.20
53.15
53.15
53.15
53.15
Black PVC
Black PE
Black PVC
Black PVC
0.341
0.322
0.341
0.360
8.66
8.18
8.66
9.14
FlexFill®
62
Coaxial Cable Electronics
Product Construction:Conductors:
• Copper per ASTM B-3Insulation/Core:
• Solid and cellular polyethylene designsShield:
• Tinned or bare copper braid• Flexfoil® shield
Jacket:• Premium PVC compound
Packaging:• Please contact Customer Service for
packaging and color options
Applications:• Suitable for RF signal transmission• Broadcast• Citizen band antenna• See Coax Connector Cross Reference,
pages 188-195
C1108RG 8/U Mini TypeUL CL2, CMCSA CMG
1354
C1154RG 8/U TypeJAN-C-17A Type
1354
C1198RG 8/U Type
1354
C1197RG 8/U TypeCSA(US) CMCSA CM
1354
C1180RG 8/U Type
CATALOGNUMBER
AWG SIZE
NOM. DCR
INSULATIONMATERIAL
INCHES mm
SHIELD COVERAGE
NOM SHLD DCR
NOMINAL O.D.
NOMINALATTENUATION
VELOCITY OFPROPAGATION,
%
NOMINALIMPEDANCE,
Ω MHz dB/100'
NOMINALCAPACITANCEpF/ft pF/mINCHES mm
16 Ga.(19x28)
BareCopper4.2 V/M
13 Ga.(7X21)Bare
Copper1.9 V/M
11 Ga.(19X24)
BareCopper1.9 V/M
11 Ga.(7x19)Bare
Copper1.2 V/M
9 1/2 Ga.SolidBare
Copper0.90 V/M
CellularPolyethylene
SolidPolyethylene
CellularPolyethylene
Cellular Polyethylene
Semi-SolidPolyethylene
0.155
0.285
0.285
0.285
0.285
3.94
7.24
7.24
7.24
7.24
95% BareCopper Braid
3.3 V/M
95% BareCopper Braid
1.2 V/M
95% BareCopper Braid
1.1 V/M
97% BareCopper Braid
1.1 V/M
100% Flexfoil®Bonded+88%
Tinned CopperBraid
1.8 V/M
80
66
78
78
84
50
52
50
50
50
11050
100200500
1000
11050
100200500
1000
11050
100200500
1000
11050
100200500
1000
11050
100200500
1000
0.260.982.303.304.908.50
14.30
0.160.561.301.902.804.707.40
0.170.571.201.802.704.707.10
0.170.571.201.802.704.707.10
0.130.400.901.301.803.004.50
25.30
29.50
26.00
26.00
24.60
83.01
96.79
85.31
85.31
80.71
Black PVC
Black PVC
Black PVC
Black PVC
Black PVC
0.242
0.405
0.405
0.405
0.405
6.15
10.29
10.29
10.29
10.29
RG 8/U Type
63
Electronics Coaxial Cable
C1160RG 11/U TypeJAN-C-17A Type
C5011RG 11/U TypeCCTVUL CL2, CATV, CMC(UL) CM
C5025RG 11/U Type
C5034RG 11/U Type
1354
C5039RG 11/U TypeUL CL2, CATV, CMCSA CMG
1354
C5044RG 11/U TypeQuad-ShieldUL CL2, CATV, CMCSA CMG
1354
CATALOGNUMBER
AWG SIZE
NOM. DCR
INSULATIONMATERIAL
INCHES mm
SHIELD COVERAGE
NOM SHLD DCR
NOMINAL O.D.
NOMINALATTENUATION
VELOCITY OFPROPAGATION,
%
NOMINALIMPEDANCE,
Ω MHz dB/100'
NOMINALCAPACITANCEpF/ft pF/mINCHES mm
RG 11/U Type
Product Construction:Conductors:
• Copper per ASTM B-3• Copper-clad steel per ASTM B-869
Insulation/Core:• Solid and cellular polyethylene designs
Shield:• Bare copper or aluminum braid• Flexfoil® shield
Jacket:• Premium PVC compound or
PE compound
Packaging:• Please contact Customer Service for
packaging and color options
Applications:• Suitable for RF signal transmission • MATV• CATV• Drop cable• CCTV• See Coax Connector Cross Reference,
pages 188-195
18 Ga.(7X26)TinnedCopper6.1 V/M
14 Ga.Solid Bare
Copper2.5 V/M
14 Ga.Solid
Copper-Clad Steel11.4 V/M
14 Ga.Solid
Copper-Clad Steel11.4 V/M
14 Ga.Solid
Copper-Clad Steel11.4 V/M
14 Ga.Solid
Copper-Clad Steel11.4 V/M
SolidPolyethylene
CellularPolyethylene
CellularPolyethylene
CellularPolyethylene
CellularPolyethylene
CellularPolyethylene
0.285
0.280
0.285
0.280
0.280
0.280
6.55
7.11
7.24
7.11
7.11
7.11
95% BareCopper Braid
1.2 V/M
100% Flexfoil®+95%
Bare CopperBraid
1.2 V/M
97% BareCopper Braid
1.2 V/M
100% Flexfoil®Bonded+40%
Aluminum Braid5.3 V/M
100% Flexfoil®Bonded+60%
Aluminum Braid4.6 V/M
(2) 100% Flexfoil®1st Bonded
(1) 61%(2) 40%
Aluminum Braids3.4 V/M
66
85
83
85
85
85
75
75
75
75
75
75
0.200.701.302.002.904.707.10
0.130.400.901.301.903.004.405.305.906.537.62
0.300.701.001.502.203.705.306.387.117.869.18
0.300.700.901.301.903.004.40
0.300.700.901.301.903.004.405.305.906.537.62
0.300.700.901.301.903.004.405.305.906.537.62
20.50
16.20
16.20
16.20
16.20
16.20
67.26
53.15
53.15
53.15
53.15
53.15
Black PVC
Black PVC
Black PE
Black PVC
Black PVC
Black PVC
0.400
.395
0.405
0.395
0.395
0.405
10.16
10.03
10.29
10.03
10.03
10.29
11050
100200500
1000
11050
100200500
10001450180022003000
11050
100200500
10001450180022003000
11050
100200500
1000
11050
100200500
10001450180022003000
11050
100200500
10001450180022003000
14 Ga.Solid
Copper-Clad Steel11.4 V/M
14 Ga.Solid
Copper-Clad Steel11.4 V/M
14 Ga.Solid
Copper-Clad Steel11.4 V/M
14 Ga.SolidBare
Copper2.5 V/M
14 Ga.Solid
Copper-Clad Steel11.4 V/M
14 Ga.Solid
Copper-Clad Steel11.4 V/M
14 Ga.Solid
Copper-Clad Steel11.4 V/M
64
Coaxial Cable Electronics
C5041RG 11/U TypeMessengered,Self-Supporting
Figure 8. Contains 0.083" galvanized steel messenger wire.
C5043RG 11/U TypeMoistureGuard™Direct Burial, Flooded
C5029RG 11/U TypeUL CL2, CMC(UL) CM
C5033RG 11/U TypeUL CL2, CMC(UL) CM
C5027RG 11/U Triaxial Type
C3528RG 11/U TypePlenumUL CL2P, CMPC(UL) CMP
C3529RG 11/U TypeQuad-ShieldPlenumUL CL2P, CMPC(UL) CMP
CATALOGNUMBER
AWG SIZE
NOM. DCR
INSULATIONMATERIAL
INCHES mm
SHIELD COVERAGE
NOM SHLD DCR
NOMINAL O.D.
NOMINALATTENUATION
VELOCITY OFPROPAGATION,
%
NOMINALIMPEDANCE,
Ω MHz dB/100'
NOMINALCAPACITANCEpF/ft pF/mINCHES mm
RG 11/U Type
Product Construction:Conductor:
• Copper-clad steel per ASTM B-3Insulation/Core:
• Cellular polyethylene designs• Cellular fluoropolymer designs
Shield:• Tinned, bare copper or aluminum braid• Flexfoil® shield
Jacket:• Premium PVC compound or
PE compoundPackaging:
• Please contact Customer Service forpackaging and color options
Applications:• Suitable for RF signal transmission • MATV• CATV• Drop cable• Direct burial• See Coax Connector Cross Reference,
pages 188-195
CellularPolyethylene
CellularPolyethylene
CellularPolyethylene
CellularPolyethylene
CellularPolyethylene
CellularFluoropolymer
CellularFluoropolymer
0.280
0.280
0.280
0.280
0.285
0.280
0.280
7.11
7.11
7.11
7.11
7.24
7.11
7.11
100% Flexfoil®Bonded+60%
Aluminum Braid5.3 V/M
100% Flexfoil®Bonded+60%
Aluminum Braidw/ water block
5.3 V/M
100% Flexfoil®Bonded+61%
Tinned CopperBraid
3.0 V/M
100% Flexfoil®Bonded+61%
Tinned CopperBraid
3.0 V/M
(2) Bare Copper97% braidsw/ Black PE
Wall Separator1.6 V/M
100% Flexfoil®Bonded+60%
Aluminum Braids4.6 V/M
(2) 100% Flexfoil®1st Bonded
(1) 60%(2) 40%
Aluminum Braids3.4 V/M
85
85
85
83
83
82
82
75
75
75
75
75
75
75
0.300.700.901.301.903.004.40
0.300.700.901.301.903.004.40
0.300.700.901.301.903.004.405.305.906.537.62
0.300.700.901.301.903.004.405.305.906.537.62
0.200.501.001.502.203.705.30
0.150.471.091.492.353.946.197.458.309.18
0.150.471.091.492.353.946.197.458.309.18
16.20
16.20
16.20
16.20
16.20
16.00
16.00
53.15
53.15
53.15
53.15
53.15
52.50
52.50
Black PVC
Black PE
Black PVC
Black PE
Black PE
Flexguard®
Natural
Flexguard®
Natural
0.395X
0.624
0.395
0.395
0.395
0.475
0.351
0.372
10.03X
15.85
10.03
10.03
10.03
12.07
8.92
9.45
11050
100200500
1000
11050
100200500
1000
11050
100200500
10001450180022003000
11050
100200500
10001450180022003000
11050
100200500
1000
11050
100200500
1000145018002200
11050
100200500
1000145018002200
FlexFill®
65
Electronics Coaxial Cable
C1117RG 58/U Type
C1155RG 58C/U TypeMIL-C-17G Type
C1166RG 58/U TypeJAN-C-17A Type
1354
C1178RG 58A/U TypeJAN-C-17A Type
1354
C5045RG 58/U Type
C1188RG 58 A/U TypeUL CL2, CMCSA CMG
1354
C3519RG 58/U TypePlenumUL CL2P, CMPC(UL) CMP
RG 58/U Type
Product Construction:Conductors:
• Copper per ASTM B-3• Tinned copper per ASTM B-33
Insulation/Core:• Solid and cellular polyethylene designs• Cellular fluoropolymer design
Shield:• Tinned copper braid
Jacket:• Premium PVC compound or
PE compound
Packaging:• Please contact Customer Service for
packaging and color options
Applications:• Suitable for RF signal transmission• Broadcast• See Coax Connector Cross Reference,
pages 188-195
CATALOGNUMBER
AWG SIZE
NOM. DCR
INSULATIONMATERIAL
INCHES mm
SHIELD COVERAGE
NOM SHLD DCR
NOMINAL O.D.
NOMINALATTENUATION
VELOCITY OFPROPAGATION,
%
NOMINALIMPEDANCE,
Ω MHz dB/100'
NOMINALCAPACITANCEpF/ft pF/mINCHES mm
20 Ga.Solid Bare
Copper10.1 V/M
20 Ga.(19X.0071)
TinnedCopper
10.8 V/M
20 Ga.Solid Bare
Copper10.1 V/M
20 Ga.(19X.0071)
TinnedCopper
10.8 V/M
20 Ga.Solid Bare
Copper10.1 V/M
20 Ga.(19X32)TinnedCopper9.5 V/M
19 Ga.Solid Bare
Copper8.1 V/M
SolidPolyethylene
SolidPolyethylene
SolidPolyethylene
SolidPolyethylene
SolidPolyethylene
CellularPolyethylene
CellularFluoropolymer
0.116
0.116
0.116
0.116
0.102
0.114
0.102
2.95
2.95
2.95
2.95
2.59
2.90
2.59
70% TinnedCopper Braid
6.0 V/M
95% TinnedCopper Braid
4.3 V/M
95% TinnedCopper Braid
4.3 V/M
95% TinnedCopper Braid
4.3 V/M
95% TinnedCopper Braid
4.3 V/M
95% TinnedCopper Braid
4.3 V/M
95% TinnedCopper Braid
2.9 V/M
66
66
66
66
78
66
82
53
50
50
50
50
50
50
11050
100200500
1000
11050
100200500
1000
11050
100200500
1000
11050
100200500
1000
11050
100200500
1000
11050
100200500
1000
11050
100200500
1000
0.401.202.904.206.00
10.1716.50
0.421.503.705.408.10
13.8622.80
0.401.202.904.206.00
10.1716.50
0.421.503.705.408.10
13.9622.80
0.401.202.904.206.00
10.1716.50
0.451.423.204.506.40
10.0614.50
0.401.302.803.906.009.50
13.50
28.50
30.80
30.00
31.80
24.00
26.00
25.00
93.51
101.05
98.43
104.34
78.74
85.31
82.00
Black PVC
Non-contaminatingBlack PVC
Black PVC
Black PVC
Permaline®
Black PE
Black PVC
Flexguard® PVCNatural
0.195
0.195
0.195
0.195
0.195
0.195
0.161
4.95
4.95
4.95
4.95
4.95
4.95
4.09
66
Coaxial Cable Electronics
C1102RG 59/U Type
C1104RG 59/U Type
1354
C1135RG 59/U TypeUL CL2, CATV, CMCSA CMG
1354
C1103RG 59/U TypeCCTVUL CL2, CATV, CMCSA CMG
1354
C1142RG 59/U TypeCCTVUL CL2, CATV, CMCSA CMG
1354
C1106RG 59B/U TypeMIL-C-17D Type
1354
C1107RG 59/U TypeCSA(US) CMCSA CMG
1354
C8030RG 59/U Type+18 AWG Unshielded PairUL CMPC(UL) CMP
RG 59/U Type
Product Construction:Conductors:
• Copper per ASTM B-3• Copper-clad steel per ASTM B-869
Insulation/Core:• Solid and cellular polyethylene designs
Shield:• Bare copper braid
Jacket:• Premium PVC compound or PE compound
Packaging:• Please contact Customer Service for packaging
and color optionsApplications:
• Suitable for RF signal transmission• CATV• MATV
• CCTV• Local Area Network• Citizen band radio• Monitor/VDT Display• See Coax Connector Cross Reference,
pages 188-195
CATALOGNUMBER
AWG SIZE
NOM. DCR
INSULATIONMATERIAL
INCHES mm
SHIELD COVERAGE
NOM SHLD DCR
NOMINAL O.D.
VELOCITY OFPROPAGATION,
%
NOMINALIMPEDANCE,
Ω
NOMINALCAPACITANCEpF/ft pF/mINCHES mm
20 Ga.Solid
Copper-Clad Steel45.9 V/M
22 Ga.Solid
Copper -Clad Steel73.4 V/M
22 Ga.Solid
Copper-Clad Steel73.4 V/M
22 Ga.(7X30)Bare
Copper14.8 V/M
20 Ga.Solid Bare
Copper10.1 V/M
23 Ga.Solid
Copper-Clad Steel68.5 V/M
23 Ga.Solid BareCopper-
Clad Steel68.5 V/M
20 AWGSolid BC
Coax
18 AWG 7/26Unshielded Pair
Cellular Polyethylene
Solid Polyethylene
Cellular Polyethylene
Cellular Polyethylene
Cellular Polyethylene
Solid Polyethylene
Cellular Polyethylene
CellularFEP
Halar
0.146
0.146
0.146
0.146
0.146
0.146
0.146
0.135
0.006
3.71
3.71
3.71
3.71
3.71
3.71
3.71
3.43
0.15
95% BareCopper Braid
3.5 V/M
95% BareCopper Braid
2.6 V/M
95% BareCopper Braid
2.6 V/M
95% BareCopper Braid
2.6 V/M
95% BareCopper Braid
2.6 V/M
95% BareCopper Braid
2.6 V/M
95% BareCopper Braid
2.6 V/M
95% Bare CopperBraid
Unshielded Pair
82
66
78
78
78
66
66
83
75
73
80
76
71
73
73
75
11050
100200500
10001450180022003000
11050
100200500
10001450180022003000
11050
100200500
10001450180022003000
11050
100200500
10001450180022003000
11050
100200500
10001450180022003000
11050
100200500
10001450180022003000
11050
100200500
10001450180022003000
11050
100200500
1000
0.260.821.802.603.706.008.80
10.6011.8113.0515.24
0.410.992.383.495.098.43
13.0315.6917.4819.3322.57
0.420.922.102.904.106.609.30
11.2012.4813.7916.11
0.260.912.093.004.337.03
10.6412.8114.2815.7818.43
0.250.781.972.793.976.359.15
11.0212.2813.5715.85
0.441.022.443.555.188.59
13.5616.3318.1920.1123.49
0.441.022.443.555.188.59
13.5616.3318.1920.1123.49
0.781.901.982.804.106.829.64
17.30
20.50
16.30
17.00
16.20
21.00
21.00
16.30
56.76
67.26
53.48
55.78
53.15
68.90
68.90
53.48
Black PE
Black PVC
Black PVC
Black PVC
Black PVC
Non-ContaminatingBlack PVC
Black PVC
Natural PVC
0.242
0.242
0.242
0.242
0.234
0.242
0.234
0.200X
0.383
6.15
6.15
6.15
6.15
5.94
6.15
5.94
5.08X
9.73
NOMINALATTENUATIONMHz dB/100'
67
Electronics Coaxial Cable
RG 59/U Type
Product Construction:Conductors:
• Copper per ASTM B-3• Copper-clad steel per ASTM B-869
Insulation/Core:• Solid and cellular polyethylene designs
Shield:• Tinned, bare copper or aluminum braid• Flexfoil® shield
Jacket:• Premium PVC compound
Packaging:• Please contact Customer Service for
packaging and color optionsApplications:
• Suitable for RF signal transmission• MATV• Local Area Network
• Citizen band radio• Monitor/VDT display• Analog video• Digital video• See Coax Connector Cross Reference,
pages 188-195
C1110RG 59/U Type
1354
C1112RG 59/U Type
C8005RG 59/U Dual-TypeUL CL2, CATV, CMCSA CMG
20063
C5834RG 59/U Dual-TypeUL CL2, CATV, CMCSA CMG
20999
C5816RG 59/U TypeAnalog VideoDigital Video
C5836RG 59/U TypeAnalog VideoUL CL2X, CMXC(UL) CMH
1354
C8025RG 59/U Type+22 AWG Shielded PairUL CL2, CATV, CMC(UL) CM
CATALOGNUMBER
AWG SIZE
NOM. DCR
INSULATIONMATERIAL
INCHES mm
SHIELD COVERAGE
NOM SHLD DCR
NOMINAL O.D.
NOMINALATTENUATION
VELOCITY OFPROPAGATION,
%
NOMINALIMPEDANCE,
Ω MHz dB/100'
NOMINALCAPACITANCEpF/ft pF/mINCHES mm
22 Ga.Solid
Copper-Clad Steel73.4 V/M
22 Ga.Solid
Copper-Clad Steel73.4 V/M
23 Ga.Solid
Copper-Clad Steel68.5 V/M
20 Ga.Solid
Copper-Clad Steel45.9 V/M
20 Ga.Solid Bare
Copper73.4 V/M
22 Ga.Solid
Copper-Clad Steel73.4 V/M
22 AWG7/30 BC
Coax
22 AWG 7/30Shielded Pair
SolidPolyethylene
CellularPolyethylene
SolidPolyethylene
CellularPolyethylene
SolidPolyethylene
SolidPolyethylene
CellularPolyethylene
Premium PVC
0.146
0.146
0.146
0.146
0.198
0.146
0.144
0.013
3.71
3.71
3.71
3.71
5.03
3.71
3.66
0.33
70% BareCopper Braid
4.5 V/M
70% BareCopper Braid
4.5 V/M
100% Flexfoil®+95%
Tinned CopperBraid
2.9 V/M
100% Flexfoil®Bonded+67%
Aluminum Braid9.7 V/M
97% TinnedCopper
Double Braid1.2 V/M
85% BareCopper Braid
2.7 V/M
95% Bare CopperBraid
125% Flexfoil®AI/PP Shielded
66
78
66
85
66
66
78
73
80
73
75
75
73
76
11050
100200500
10001450180022003000
11050
100200500
10001450180022003000
11050
100200500
10001450180022003000
11050
100200500
10001450180022003000
11050
100200500
1000
11050
100200500
10001450180022003000
11050
100200500
1000
0.410.992.383.495.098.43
13.0315.6917.4819.3322.57
0.420.922.102.904.106.609.30
11.2012.4813.7916.11
0.441.022.443.555.188.59
13.5616.3318.1920.1123.49
0.601.201.952.703.705.708.129.78
10.8912.0414.06
0.250.781.702.503.705.909.20
0.410.992.383.495.098.43
13.0315.6917.4819.3322.57
0.260.912.903.004.337.03
10.64
22.00
16.30
21.00
16.20
21.00
21.00
17.00
72.18
53.48
68.90
53.15
68.90
68.90
55.78
Black PVC
Black PVC
Black PVC
Black PVC
Black PVC
Black PVC
Black PVC
0.242
0.242
0.242X
0.498
0.242X
0.498
0.305
.242
0.242X
0.445
6.15
6.15
6.15X
12.65
6.15X
12.65
7.75
6.15
6.147X
11.30
68
Coaxial Cable Electronics
C5770RG 59/U TypeUL CL2, CATV, CMCSA CMG
1354
C5780RG 59/U TypeMATVUL CL2, CATV, CMCSA CMG
1354
C5782RG 59/U TypeUL CL2, CATV, CMCSA CMG
1354
C5832RG 59/U TypeUL CL2, CATV, CMC(UL) CM
C5831RG 59/U TypeTri-ShieldUL CL2, CATV, CMC(UL) CM
C5830RG 59/U TypeTri-ShieldUL CL2, CATV, CMC(UL) CM
C5784RG 59/U TypeQuad-ShieldUL CL2, CATV, CMCSA CMG
1354
CATALOGNUMBER
AWG SIZE
NOM. DCR
INSULATIONMATERIAL
INCHES mm
SHIELD COVERAGE
NOM SHLD DCR
NOMINAL O.D.
RG 59/U Type
Product Construction:Conductors:
• Copper-clad steel per ASTM B-869Insulation/Core:
• Cellular polyethylene designsShield:
• Aluminum braid• Flexfoil® shield
Jacket:• Premium PVC compound
Packaging:• Please contact Customer Service for
packaging and color options
Applications:• Suitable for RF signal transmission• CATV• MATV• Drop cable• Local Area Network• Citizen band radio• Monitor/VDT display• See Coax Connector Cross Reference, pages 188-195
NOMINALATTENUATION
VELOCITY OFPROPAGATION,
%
NOMINALIMPEDANCE,
Ω MHZ dB/100'
NOMINALCAPACITANCEpF/ft pF/mINCHES mm
22 Ga.Solid
Copper-Clad Steel73.4 V/M
20 Ga.Solid
Copper-Clad Steel45.9 V/M
20 Ga.Solid
Copper-Clad Steel45.9 V/M
20 Ga.Solid
Copper-Clad Steel45.9 V/M
20 Ga.Solid
Copper-Clad Steel45.9 V/M
20 Ga.Solid
Copper-Clad Steel45.9 V/M
20 Ga.Solid
Copper-Clad Steel45.9 V/M
CellularPolyethylene
CellularPolyethylene
CellularPolyethylene
CellularPolyethylene
CellularPolyethylene
CellularPolyethylene
CellularPolyethylene
0.144
0.144
0.144
0.144
0.144
0.144
0.144
3.66
3.66
3.66
3.66
3.66
3.66
3.66
100% Flexfoil®Bonded+40%
Aluminum Braid11.0 V/M
100% Flexfoil®Bonded+40%
Aluminum Braid11.0 V/M
100% Flexfoil®Bonded+67%
Aluminum Braid9.7 V/M
100% Flexfoil®Bonded+95%
Aluminum Braid4.1 V/M
100% Flexfoil®Bonded+67%
Aluminum Braid+100% Flexfoil®
11.0 V/M
100% Flexfoil®Bonded+95%
Aluminum Braid+100% Flexfoil®
3.0 V/M
100% Flexfoil®1st Bonded
(1) 67%(2) 46%
Aluminum Braids4.1 V/M
78
85
85
85
85
85
85
80
75
75
75
75
75
75
11050
100200500
10001450180022003000
11050
100200500
10001450180022003000
11050
100200500
10001450180022003000
11050
100200500
10001450180022003000
11050
100200500
10001450180022003000
11050
100200500
10001450180022003000
11050
100200500
10001450180022003000
0.501.002.303.304.106.509.40
11.3212.6113.9416.28
0.601.201.952.703.705.708.129.78
10.8912.0414.06
0.601.201.952.703.705.708.129.78
10.8912.0414.06
0.601.201.952.703.705.708.129.78
10.8912.0414.06
0.601.201.952.703.705.708.129.78
10.8912.0414.06
0.601.201.952.703.705.708.129.78
10.8912.0414.06
0.601.201.952.703.705.708.129.78
10.8912.0414.06
16.00
16.20
16.20
16.20
16.20
16.20
16.20
52.50
53.15
53.15
53.15
53.15
53.15
53.15
Black PVC
Black PVC
Black PVC
Black PVC
Black PVC
Black PVC
Black PVC
0.231
0.234
0.234
0.237
0.242
0.242
0.270
5.87
5.94
5.94
6.02
6.15
6.15
6.86
69
Electronics Coaxial Cable
RG 59/U Type
Product Construction:Conductors:
• Copper-clad steel per ASTM B-869Insulation/Core:
• Cellular polyethylene andcellular fluoropolymer designs
Shield:• Bare copper or aluminum braid• Flexfoil® shield
Jacket:• Premium PVC compound or
PE compoundPackaging:
• Please contact Customer Service forpackaging and color options
Applications:• Suitable for RF signal transmission• MATV• Local Area Network• Citizen band radio• Monitor/VDT display• Direct burial• See Coax Connector Cross Reference,
pages 188-195
C5842RG 59/U TypeMessengered,Self-Supporting
Figure 8. Contains 0.051" galvanized steel messenger wire.
C5844RG 59/U TypeMoistureGuard™Direct Burial, Flooded
C1158RG 59/U TypeMiniature Type
1354
C3526RG 59/U TypePlenumUL CL2P, CMPC(UL) CMP
C3527RG 59/U TypeQuad-ShieldPlenumUL CL2P, CMPC(UL) CMP
C3500RG 59/U TypePlenumUL CL2P, CMPC(UL) CMP
C8027RG 59/U Type+18 AWG Shielded PairUL CL2, CATV, CMC(UL) CM
C8028RG 59/U Type+18 AWG Unshielded PairUL CL2, CATV, CMC(UL) CM
CATALOGNUMBER
AWG SIZE
NOM. DCR
INSULATIONMATERIAL
INCHES mm
SHIELD COVERAGE
NOM SHLD DCR
NOMINAL O.D.
NOMINALATTENUATION
VELOCITY OFPROPAGATION,
%
NOMINALIMPEDANCE,
Ω MHz dB/100'
NOMINALCAPACITANCEpF/ft pF/mINCHES mm
20 Ga.Solid
Copper-Clad Steel45.9 V/M
20 Ga.Solid
Copper-Clad Steel45.9 V/M
27 Ga.(7X35)
Copper-Clad Steel120.0 V/M
20 Ga.Solid
Copper-Clad Steel45.9 V/M
20 Ga.Solid
Copper-Clad Steel45.9 V/M
20 Ga.Solid
Copper-Clad Steel45.9 V/M
22 AWG7/30 BC
Coax
18 AWG 16/30Shielded Pair
20 AWGSolid BC
Coax
18 AWG 7/26Unshielded Pair
CellularPolyethylene
CellularPolyethylene
SolidPolyethylene
CellularFluoropolymer
CellularFluoropolymer
CellularFluoropolymer
CellularPolyethylene
Premium PVC
CellularPolyethylene
Premium PVC
0.146
0.146
0.100
0.135
0.135
0.145
0.144
0.016
0.144
0.010
3.71
3.71
2.54
3.429
3.429
3.68
3.66
0.41
3.66
0.25
100% Flexfoil®Bonded+67%
Aluminum Braid9.7 V/M
100% Flexfoil®Bonded+67%
Aluminum Braidw/ water block
9.7 V/M
93% TinnedCopper Braid
6.5 V/M
100% Flexfoil®+65%
Aluminum Braid10.7 V/M
(2) 100% Flexfoil®1st Bonded
(1) 60%(2) 40%
Aluminum Braid6.3 V/M
95% BareCopper Braid
1.9 V/M
95% Bare CopperBraid
125% Flexfoil®AI/PP Shielded
95% Bare CopperBraid
Unshielded Pair
85
85
66
84
84
82
78
78
75
75
75
75
75
75
76
71
0.601.201.952.703.705.708.12
0.601.201.952.703.705.708.121.202.404.205.708.30
13.5320.00
0.341.071.772.503.535.988.45
14.10
0.341.071.772.503.535.988.45
14.10
0.781.901.982.804.106.829.64
0.260.912.093.004.337.03
10.64
0.250.781.972.703.976.359.15
16.20
16.20
20.50
16.00
16.00
16.50
17.00
16.20
53.15
53.15
67.26
52.50
52.50
54.14
55.78
53.15
Black PVC
Black PE
Black PVC
Flexguard®
Natural
Flexguard®
Natural
Flexguard® PVCNatural
Black PVC
Black PVC
0.242X
0.395
0.242
0.150
0.202
0.235
0.201
0.242X
0.480
0.238X
0.440
6.15X
10.03
6.15
3.81
5.13
5.97
5.11
6.15X
12.19
6.05X
11.18
11050
100200500
1000
11050
100200500
10001
1050
100200500
1000
11050
100200500
10002300
11050
100200500
10002300
11050
100200500
1000
11050
100200500
1000
11050
100200500
1000
FlexFill®
70
Coaxial Cable Electronics
RG 62/U Type
Product Construction:Conductors:
• Copper-clad steel per ASTM B-869Insulation/Core:
• Semi-solid polyethylene designs• Cellular fluoropolymer design
Shield:• Bare copper braid
Jacket:• Premium PVC compound
Packaging:• Please contact Customer Service for
packaging and color options
Applications:• Suitable for RF signal transmission• Computer• See Coax Connector Cross Reference,
pages 188-195
C1162RG 62A/U TypeMIL-C-17G Type
1354
C1164RG 62/U TypeComputer CableJAN-C-17A TypeUL CL2, CMCSA CMG
1354
C3520RG 62/U TypePlenumUL CL2P, CMPC(UL) CMP
CATALOGNUMBER
AWG SIZE
NOM. DCR
INSULATIONMATERIAL
INCHES mm
SHIELD COVERAGE
NOM SHLD DCR
NOMINAL O.D.
NOMINALATTENUATION
VELOCITY OFPROPAGATION,
%
NOMINALIMPEDANCE,
Ω MHZ dB/100'
NOMINALCAPACITANCEpF/ft pF/mINCHES mm
22 Ga.Solid
Copper-Clad Steel73.4 V/M
22 Ga.Solid
Copper-Clad Steel73.4 V/M
22 Ga.Solid
Copper-Clad Steel54.7 V/M
Semi-SolidPolyethylene
Semi-SolidPolyethylene
CellularFluoropolymer
0.146
0.146
0.145
3.71
3.66
3.56
95% BareCopper Braid
2.6 V/M
95% BareCopper Braid
2.6 V/M
95% BareCopper Braid
1.9 V/M
84
84
84
93
93
93
11050
100200500
1000
11050
100200500
1000
11050
100200500
1000
0.380.851.902.703.805.908.70
0.380.851.902.703.805.908.70
0.300.901.902.703.805.908.34
13.60
13.60
13.00
44.62
44.62
42.65
Non-contaminatingBlack PVC
Black PVC
Flexguard® PVCNatural
0.242
0.242
0.201
6.15
6.15
5.11
71
Electronics Coaxial Cable
RG 174/U Type
Product Construction:Conductors:
• Copper per ASTM B-3• Copper-clad steel per ASTM B-869
Insulation/Core:• Solid polyethylene designs
Shield:• Tinned or bare copper braid
Jacket:• Premium PVC compound
Packaging:• Please contact Customer Service for
packaging and color options
Applications:• Suitable for RF signal transmission• MATV• CATV• CCTV• See Coax Connector Cross Reference,
pages 188-195
C1156 RG 174/U Type
1354
CATALOGNUMBER
AWG SIZE
NOM. DCR
INSULATIONMATERIAL
INCHES mm
SHIELD COVERAGE
NOM SHLD DCR
NOMINAL O.D.
NOMINALATTENUATION
VELOCITY OFPROPAGATION,
%
NOMINALIMPEDANCE,
Ω MHZ dB/100'
NOMINALCAPACITANCEpF/ft pF/mINCHES mm
26 Ga. (7x34)
Copper-Clad Steel97.0 V/M
Solid Polyethylene
0.060 1.52
95% Tinned CopperBraid
10.3 V/M
66 50 11050
100200500
1000
1.903.305.808.40
12.5021.2134.00
30.80 101.05Black PVC
0.103 2.62
C1176 RG 213/U Type MIL-C-17G Type
1354
CATALOGNUMBER
AWG SIZE
NOM. DCR
INSULATIONMATERIAL
INCHES mm
SHIELD COVERAGE
NOM SHLD DCR
NOMINAL O.D.
NOMINALATTENUATION
VELOCITY OFPROPAGATION,
%
NOMINALIMPEDANCE,
Ω MHZ dB/100'
NOMINALCAPACITANCEpF/ft pF/mINCHES mm
13 Ga.(7x21) Bare
Copper 1.7 V/M
Solid Polyethylene
0.285 7.24
95% Bare CopperBraid
1.2 V/M
66 50 11050
100200500
1000
0.180.621.502.103.005.038.20
30.80 101.05Black PVC
0.405 10.29
RG 213/U Type
72
Coaxial Cable Electronics
Other Coaxial Cables
Product Construction:Conductors:
• Copper per ASTM B-3• Tinned copper per ASTM B-33
Insulation/Core:• Solid and cellular polyethylene designs• Cellular fluoropolymer design
Shield:• Tinned copper braid• Flexfoil® shield
Jacket:• Premium PVC compound
Packaging:• Please contact Customer Service for
packaging and color options
Applications:• Precision video• Thinnet• See Coax Connector Cross Reference,
pages 188-195
C5838RG 59/U TypeIndoor UsePrecision Video
C5779RG 58/U TypeThinnetUL CL2, CMCSA CMG
1354
C3579RG 58/U TypeThinnetPlenumUL CL2P, CMPC(UL) CMP
CATALOGNUMBER
AWG SIZE
NOM. DCR
INSULATIONMATERIAL
INCHES mm
SHIELD COVERAGE
NOM SHLD DCR
NOMINAL O.D.
NOMINALATTENUATION
VELOCITY OFPROPAGATION,
%
NOMINALIMPEDANCE,
Ω MHZ dB/100'
NOMINALCAPACITANCEpF/ft pF/mINCHES mm
20 Ga.Solid Bare
Copper10.1 V/M
20 Ga.Stranded(19X32)TinnedCopper9.5 V/M
20 Ga.(19X32)TinnedCopper9.5 V/M
SolidPolyethylene
CellularPolyethylene
CellularFluoropolymer
0.200
0.100
0.100
5.08
2.54
2.54
98% TinnedCopper
Double Braid1.1 V/M
100% Flexfoil®Bonded+81%
Tinned CopperBraid
9.5 V/M
100% Flexfoil®+95%
Tinned CopperBraid
3.1 V/M
66
80
78
77
50
50
11050
100200500
1000
11050
100200500
1000
11050
100200500
1000
0.250.781.702.503.705.939.20
0.401.202.904.306.20
10.0014.00
0.601.302.904.206.10
10.0014.80
20.00
25.40
26.00
65.62
83.34
85.31
Clear PVC
Gray PVC
Flexguard® PVCNatural
0.305
0.186
0.165
7.75
4.72
4.19
73
Electronics Coaxial Cable
C8000UL CL2
249880°C, 300V
C8001UL CL2, CMC(UL) CM
24642582
60°C, 300V
C80122092
80°C, 300V
C80132448
60°C, 30V
C80142668
60°C, 30V
C80332092
60°C, 300V
CATALOGNUMBER
AWG SIZE
NOM. DCR
INSULATIONMATERIAL
INCHES mm
SHIELD COVERAGE
NOM SHLD DCR
NOMINAL O.D.
Twinaxial Cables
Product Construction:Conductors:
• Copper per ASTM B-3• Tinned copper per ASTM B-33
Insulation/Core:• Solid and cellular polyethylene designs• Lo-Cap® polypropylene designs
Shield:• Tinned copper braid• Flexfoil® shield
Jacket:• Premium PVC compound
Packaging:• Please contact Customer Service for
packaging and color options
Applications:• Programmable Logic Controllers (PLC)• Data transmission• Broadcast• Computer
NOMINALATTENUATION
VELOCITY OFPROPAGATION,
% MHZ dB/100'
NOMINALCAPACITANCEpF/ft pF/mINCHES mm
20 Ga.(7X28)
(1) TinnedCopper,(1) BareCopper9.5 V/M
20 Ga.(7X28)TinnedCopper9.5 V/M
25 Ga.(7X33)TinnedCopper
31.8 V/M
16 Ga.Solid Bare
Copper4.2 V/M
22 Ga.(19X34)TinnedCopper
15.0 V/M
22 Ga.(7X30)
(1) TinnedCopper,(1) BareCopper
16.0 V/M
Solid PolyethyleneCoded:
Natural, Natural
Solid PolyethyleneCoded:
Natural, Blue
Solid PolyethyleneCoded:
Natural, Blue
Cellular PolyethyleneCoded:
Natural, Blue
Lo-Cap® PolypropyleneCoded:
Black, Yellow
Solid PolyethyleneCoded:
White, Blue
0.022
0.020
0.030
0.052
0.051
0.015
0.56
0.51
0.76
1.32
1.30
0.38
100% Flexfoil®+90%
Tinned CopperBraid
2.5 V/M
100% Flexfoil®+57%
Tinned CopperBraid
4.1 V/M
100% Flexfoil®+25 AWG
Tinned CopperDrain Wire12.0 V/M
100% Flexfoil®+92%
Tinned CopperBraid
6.3 V/M
100% Flexfoil®+22 AWG
Tinned CopperDrain Wire6.3 V/M
85% TinnedCopper Braid
4.7 V/M
66
66
66
78
78
66
11050
100200400
11050
100200400
11050
100200400
11050
100200400
11050
100200400
11050
100200400
0.401.102.504.106.40
10.20
0.602.105.007.50
11.0016.00
0.601.703.605.006.909.60
0.180.711.802.904.106.20
0.401.202.654.306.208.80
0.802.505.708.00
11.4016.10
15.50
19.17
12.20
10.90
8.80
20.70
50.86
62.90
40.03
35.76
28.87
67.92
Black PVC
Blue PVC
Blue PVC
Black PVC
Black PVC
Beige PVC
0.330
0.242
0.240
0.440
0.360
0.180
8.38
6.15
6.10
11.18
9.14
4.57
NOMINALIMPEDANCE,
Ω
100
78
124
120
150
78
74
Electronics
Helix/HiTemp™ Coaxial Cable
Index Page
RG 6 & RG 11 BroadbandQuad Shield Cable 75RG 8/U Type Cable 76RG 8/U Type Thicknet/ Trunk Cable 77RG 58/U Type Cable 78-79RG 58/U Type Thinnet Cable 80Headend CATV Drop Cable 81Headend Tinned Copper Drop Cable 82RG 213, RG 214, RG 174 Cable 83
To meet the needs of today’ssophisticated, high-speed, widebandwidth electronics over longdistances with minimum signalloss, General Cable Helix/HiTemp™ offers a wide range ofcoaxial designs. This offeringprovides the system designerwith a wide choice of cost-effective products that reflectthe most recent changes in thestandards set forth by UL, CSAand/or the FCC.
Unlike other products in theelectronics market, coaxial cabledoes not have one acceptedstandard construction. GeneralCable recommends consultingwith the local CATV company, in order to avoid installing anunacceptable coaxial cable for the CATV application in your area.
General Cable’s Helix/HiTempproduct mix encompassesstandard RG/U-type coaxialconstructions in the morepopular 50 and 75 Ohm designsfor video, CATV, MATV, networkand computer applications.
75
Electronics Coaxial Cable
RG 6 & RG 11 Broadband Quad Shield Cable75 Ohm High-End Coaxial Cables for Video, CATV, MATV & Network Applications
RG 6/U QUAD SHIELD, RISER RATED
RG 6/U QUAD SHIELD, PLENUM RATED
RG 11/U QUAD SHIELD, PLENUM RATED
Part No.& SafetyRatings
Cond.Size/Type
& DCR
InsulationType Nom.O.D. in/mm
Shield Type &DCR/KFt
Jacket & Nom.Dia. in/mm
Nom.Imp.Ohm
Nom.Vel. ofProp.
NominalCapacitance
pF/ft pF/m
Nominal Attenuation
MHz dB/ dB/100FT 100m
395014UL CMR
C(UL) CMG75˚C / 300V
495024UL CMP
c(UL) CMP75˚C / 300V
495017UL CMP
c(UL) CMP125˚C / 300V
18Solid BC
(6.5 Ohm)
18Solid BC
(6.5 Ohm)
14Solid BC
(2.6 Ohm)
Foam PEGas Injection0.180 / 4.57
Foam FEP0.170 / 4.32
Foam FEP0.285 / 7.24
Quad Shield;AL Foil + 60% ALBraid + AL Foil +40% AL Braid
(5.2 Ohm)
Quad Shield;AL Foil + 60% ALBraid + AL Foil +40% AL Braid
(5.3 Ohm)
Quad Shield;AL Foil + 60% ALBraid + AL Foil +40% AL Braid
(1.8 Ohm)
Flame-RetardantPVC
0.305 / 7.75
Plenum-PVC0.264 / 6.71
PVDF0.380 / 9.65
16.2 53.2 75 83%
15.5 50.8 75 84%
16.0 52.5 75 84%
1 0.21 0.693.6 0.40 1.315 0.54 1.7710 0.76 2.5150 1.39 4.5755 1.46 4.79
71.5 1.66 5.4688.5 1.85 6.08100 1.97 6.46135 2.11 6.93180 2.44 8.00200 2.57 8.43211 2.64 8.66270 2.99 9.80360 3.53 11.58400 3.72 12.21500 4.16 13.65540 4.32 14.18700 5.01 16.45750 5.19 17.03862 5.56 18.26900 5.73 18.801000 6.04 19.821450 7.97 26.151500 8.11 26.601800 8.42 27.632250 10.19 33.433000 11.77 38.61
1 0.26 0.853.6 0.49 1.625 0.58 1.9110 0.70 2.3050 1.48 4.86
71.5 1.77 5.8188.5 1.89 6.20100 2.01 6.59135 2.34 7.66180 2.71 8.90200 2.86 9.38270 3.32 10.90360 4.01 13.17400 4.23 13.88540 4.91 16.13700 5.96 19.55750 6.17 20.24900 6.96 22.841000 7.45 24.441450 11.50 37.731500 11.70 38.381800 13.10 42.982250 14.80 48.563000 17.09 56.07
1 0.15 0.493.6 0.28 0.9310 0.39 1.2850 1.10 3.61
71.5 1.32 4.3288.5 1.60 5.25100 1.70 5.58135 1.98 6.48180 2.37 7.78200 2.50 8.20270 5.64 18.50360 3.32 10.89400 3.50 11.48540 4.07 13.34700 4.60 15.09750 4.76 15.62900 9.30 30.511000 5.60 18.371500 6.86 22.502250 8.40 27.563000 9.70 31.82
76
Coaxial Cable Electronics
RG 8/U Type Cable50 Ohm LAN & Data Transmission Computer Cables
Part No.& SafetyRatings
Cond.Size/Type
& DCR
InsulationType Nom.O.D. in/mm
Shield Type &DCR/KFt
Jacket & Nom.Dia. in/mm
Nom.Imp.Ohm
Nom.Vel. ofProp.
NominalCapacitance
pF/ft pF/m
Nominal Attenuation
MHz dB/ dB/100FT 100m
395009UL- CMR c(UL)
AWM-135475˚C / 300V
395062AWM-1354
-40˚C to +80˚C300V
495029UL-CMP c(UL)
Plenum150˚C / 300V
395059UL-CM c(UL)AWM-135475˚C / 300V
395159Outdoor Rated
Triax-55˚C to +80˚C
300V
395022JAN-C-17A
UL/CMX c(UL)AWM-135475˚C / 300V
395053RG-8x Mini
UL/CM c(UL)AWM-135475˚C / 300V
10 AWGSolid BC (.108)
.9 / 2.96
11 AWG(7/19) (.108)Stranded BC
1.2 / 3.94
10 AWGSolid BC (.108)
.9 / 2.96
11 AWG(7/19) (.108)Stranded BC
1.2 / 3.94
11 AWG(7/19) (.108)Stranded BC
1.2 / 3.94
13 AWG(7/21) (.085)Stranded BC1.74 / 5.71
16 AWG(19/.011721)
(.058)Stranded BC4.06 / 13 / 31
Foam High-Density
PolyethyleneGas-Injected.285 / 7.24
Foam HighDensity
PolyethyleneGas-Injected.285 / 7.24
Foam FEP.285 / 7.24
Foam PE.285 / 7.24
Foam PE.285 / 7.24
Solid PE.285 / 7.24
Foam High-Density
PolyethyleneGas-Injected.285 / 7.24
BondedDual Foil+ 95% TC
Braid Shield1.10 / 3.61
BondedDual Foil+ 95% TC
Braid Shield1.10 / 3.61
BondedDual Foil+ 90% TC
Braid Shield1.60 / 5.90
Braid Shield+ 97% BC1.10 / 3.61
Inner:96% BC Braid
(1.32/4.33)
Outer:96% BC Braid
1.31 / 4.30
Braid Shield97% BC
1.20 / 3.94
Braid Shield95% BC
3.23 / 10.59
Flame-RetardantPVC
0.405 / 10.29
TPE0.405 / 10.29
PVDF.355 / 9.02
Flame-RetardantPVC
.405 / 10.29
Inner: PE.365 / 9.27
Outer: PE.408 / 12.19
NonContaminating
PVC.405 / 10.29
Flame-RetardantPVC
.242 / 6.15
24.5 80.35 50 83%
24.5 80.35 50 83%
24.2 79.38 50 84%
26.0 85.28 50 78%
26.0 85.28 50 78%
28.5 93.48 50 66%
25.0 82.0 50 82%
1 0.14 0.455 0.31 1.0210 0.44 1.4550 1.01 3.32100 1.45 4.77200 2.11 6.91400 3.08 10.11700 4.22 13.86900 4.88 16.011000 5.19 17.032000 7.85 25.754000 12.11 39.75
1 0.16 0.535 0.32 1.0510 0.46 1.5150 1.05 3.44100 1.51 4.95200 2.19 7.18400 3.16 10.36700 4.32 13.87900 4.98 16.331000 5.26 17.252000 8.03 26.344000 12.45 40.84
1 0.13 0.425 0.30 0.9510 0.42 1.3650 0.98 3.18100 1.42 4.67200 2.11 6.92400 3.18 10.45700 4.50 14.78900 5.28 17.361000 5.67 18.582000 9.01 29.574000 14.76 48.39
1 0.13 0.435 0.32 1.0410 0.45 1.4750 1.03 3.37100 1.48 4.86200 2.15 7.06400 3.16 10.35700 4.33 14.22900 5.02 16.461000 5.34 17.512000 8.11 26.614000 12.59 41.31
1 0.13 0.435 0.32 1.0410 0.45 1.4750 1.03 3.37100 1.48 4.86200 2.15 7.06400 3.16 10.35700 4.33 14.22900 5.02 16.461000 5.34 17.512000 8.11 26.614000 12.59 41.31
1 0.16 0.535 0.36 1.1810 0.58 1.9050 1.23 4.03100 1.81 5.94200 2.68 8.79400 4.07 13.35700 5.60 18.37900 6.47 21.221000 6.88 22.572000 10.44 34.244000 16.18 53.07
1 0.25 1.871 0.57 2.665 0.81 6.0210 1.84 8.5950 2.62 12.33100 3.76 17.78200 5.42 24.04400 7.33 27.57700 8.41 29.21900 8.91 43.051000 13.12 64.362000 19.62 4.674000 0.84 6.92
77
Electronics Coaxial Cable
RG 8/U Type Thicknet/Trunk Cable50 Ohm IEEE 802.3 and ISO/IEC 8802.3 10 Base 5 LAN and Computer Cables
Part No.& SafetyRatings
Cond.Size/Type
& DCR
InsulationType Nom.O.D. in/mm
Shield Type &DCR/KFt
Jacket & Nom.Dia. in/mm
Nom.Imp.Ohm
Nom.Vel. ofProp.
NominalCapacitance
pF/ft pF/m
Nominal Attenuation
MHz dB/ dB/100FT 100m
397001ThicknetDEC 17-
000451-00UL-CM c(UL)75˚C / 300V
497001ThicknetDEC 17-
000324-00UL-CMP c(UL)
Plenum125˚C / 300V
12 AWGSolid BC(.0855")
1.42 / 4.66
12 AWGSolid BC(.0855")
1.42 / 4.66
Foam PE0.245 / 6.22
Foam FEP0.245 / 6.22
Quad ShieldDual Foil
+ 94% TC Braid+ Dual Foil + 94%
TC Braid1.52 / 4.99
Quad ShieldDual Foil
+ 94% TC Braid+ Dual Foil + 94%
TC Braid1.52 / 4.99
YellowFlame-Retardant
PVC.405 / 10.29
OrangePVDF
.375 / 9.53
26.0 85.3 50 78%
25.0 82.0 50 84%
1 0.17 0.545 0.37 1.2110 0.53 1.7250 1.20 3.93100 1.73 5.65200 2.50 8.17400 3.64 11.92700 4.97 16.31900 5.74 18.831000 6.10 20.01
1 0.16 0.535 0.35 1.1510 0.51 1.6550 1.19 3.90100 1.75 5.74200 2.61 8.56400 3.97 13.01700 5.65 18.54900 6.67 21.881000 7.14 23.42
78
Coaxial Cable Electronics
RG 58/U Type Cable50 Ohm LAN & Data Transmission Cables
Part No.& SafetyRatings
Cond.Size/Type
& DCR
InsulationType Nom.O.D. in/mm
Shield Type &DCR/KFt
Jacket & Nom.Dia. in/mm
Nom.Imp.Ohm
Nom.Vel. ofProp.
NominalCapacitance
pF/ft pF/m
Nominal Attenuation
MHz dB/ dB/100FT 100m
397108UL-CM c(UL)AWM 135475˚C / 300V
397008UL-CMR c(UL)
AWM 135475˚C / 300V
397106UL-CM c(UL)AWM 135475˚C / 300V
497105UL-CMP c(UL)
Plenum75˚C / 300V
20 AWG(19/32)
Stranded TCC9.47 / 31.06
20 AWG(19/32)
Stranded TCC9.47 / 31.06
20 AWGSolid BC
10.3 / 33.78
20 AWGSolid BC
10.3 / 33.78
Foam PE0.102 / 2.59
Foam PE0.102 / 2.59
Solid PE0.116 / 2.95
Solid FEP0.106 / 2.69
Braid Shield;95%
Tinned Copper4.19 / 13.74
Dual Foil+ 56%
Tinned CopperBraid Shield9.50 / 31.16
Braid Shield+ 95%
Tinned Copper4.19 / 13.74
Braid Shield+ 95%
Tinned Copper4.0 / 13.12
Flame-RetardantPVC
.193 / 4.90
Flame-RetardantPVC
.193 / 4.90
Flame-RetardantPVC
.193 / 4.90
Plenum-PVC.159 / 4.04
26.0 85.3 53 78%
26.5 86.9 52 78%
28.5 93.5 51.5 66%
26.4 86.59 53 69%
1 0.36 1.183.6 0.67 2.205 0.79 2.5910 1.12 3.6750 2.54 8.33
71.5 3.04 9.9788.5 3.41 11.17100 3.62 11.88135 0.42 1.38180 4.91 16.12200 5.15 16.90270 6.02 19.75360 7.06 23.16400 7.44 24.41540 8.64 28.36700 10.00 32.81750 10.35 33.96900 11.44 37.531000 12.11 39.731500 14.83 48.662250 18.17 59.603000 20.98 68.82
1 0.50 1.643.6 0.94 3.095 1.11 3.6410 1.57 5.1550 3.51 11.52
71.5 4.20 13.7788.5 4.67 15.31100 4.96 16.27135 5.76 18.91180 6.67 21.88200 7.03 23.07270 8.17 26.80360 9.44 30.97400 9.95 32.65540 11.56 37.93700 13.18 43.24750 13.64 44.76900 14.95 49.051000 15.76 51.711500 19.30 63.332250 23.64 77.563000 27.30 89.56
1 0.39 1.283.6 0.74 2.425 0.87 2.8510 1.23 4.0450 2.79 9.15
71.5 3.34 10.9588.5 3.73 12.25100 3.97 13.03135 4.61 15.13180 5.38 17.65200 5.67 18.60270 6.59 21.62360 7.73 25.37400 8.15 26.74540 9.47 31.07700 10.96 35.96750 11.34 37.22900 12.53 41.111000 13.27 43.541500 16.25 53.322250 19.91 65.313000 22.98 75.41
1 0.39 1.283.6 0.76 2.515 0.90 2.9510 1.28 4.2050 3.05 10.01
71.5 3.65 11.9788.5 4.22 13.86100 4.49 14.73135 5.22 17.12180 6.38 20.92200 6.72 22.05270 7.81 25.62360 9.72 31.90400 10.25 33.63540 11.91 39.07700 14.64 48.03750 15.15 49.72900 17.27 56.661000 18.53 60.801500 22.69 74.462250 27.80 91.203000 32.09 105.30
79
Electronics Coaxial Cable
RG 58/U Type Cable50 Ohm LAN & Data Transmission Cables
Part No.& SafetyRatings
Cond.Size/Type
& DCR
InsulationType Nom.O.D. in/mm
Shield Type &DCR/KFt
Jacket & Nom.Dia. in/mm
Nom.Imp.Ohm
Nom.Vel. ofProp.
NominalCapacitance
pF/ft pF/m
Nominal Attenuation
MHz dB/ dB/100FT 100m
495011UL-CMP Plenum
125˚C / 300V
20 AWGSolid BC
10.3 / 33.78
Solid FEP0.106 / 2.69
Braid Shield;95%
Tinned Copper4.0 / 13.12
PVDF.193 / 4.90
26.4 86.59 53 69% 1 0.39 1.283.6 0.76 2.515 0.90 2.9510 1.28 4.2050 3.05 10.01
71.5 3.65 11.9788.5 4.22 13.86100 4.49 14.73135 5.22 17.12180 6.38 20.92200 6.72 22.05270 7.81 25.62360 9.72 31.90400 10.25 33.63540 11.91 39.07700 14.64 48.03750 15.15 49.72900 17.27 56.661000 18.53 60.801500 22.69 74.462250 27.80 91.203000 32.09 105.30
80
Coaxial Cable Electronics
RG 58/U Type Thinnet Cable 50 Ohm IEEE 802.3 and ISO/IEC 8802.3 10 Base 2 Computer Cables
Part No.& SafetyRatings
Cond.Size/Type
& DCR
InsulationType Nom.O.D. in/mm
Shield Type &DCR/KFt
Jacket & Nom.Dia. in/mm
Nom.Imp.Ohm
Nom.Vel. ofProp.
NominalCapacitance
pF/ft pF/m
Nominal Attenuation
MHz dB/ dB/100FT 100m
397002Thinnet
DEC 17-01248-00
UL-CM c(UL)75˚C / 300V
397107Thinnet
UL-CMX c(UL)AWM 135475˚C / 300V
397009Thinnet
Outdoor Rated-65˚C to +80˚C
300V
497022Thinnet
DEC 17-01246-00
UL-CMP c(UL)Plenum
75˚C / 300V
497002Thinnet
DEC 17-01246-00
UL-CMP c(UL)Plenum
150˚C / 300V
20 AWG(19/32)
Stranded TCC9.47 / 31.06
21 AWG(19/33)
Stranded TCC10.46 / 34.31
20 AWG(19/32)
Stranded TCC9.47 / 31.06
20 AWG(19/32)
Stranded TCC9.47 / 31.06
20 AWG(19/32)
Stranded TCC9.47 / 31.06
Foam PE0.102 / 2.59
Solid PE0.116 / 2.95
Solid PE0.116 / 2.95
Foam FEP0.100 / 2.54
Foam PE0.100 / 2.54
BondedDual Foil+ 93%
Tinned CopperBraid Shield5.40 / 17.71
Braid Shield95%
Tinned Copepr4.1 / 13.44
Braid Shield95%
Tinned Copper4.1 / 13.44
BondedDual Foil+ 93%
Tinned CopperBraid Shield5.40 / 17.71
BondedDual Foil+ 93%
Tinned CopperBraid Shield5.40 / 17.71
Flame-RetardantPVC
.183 / 4.65
Flame-RetardantPVC
.193 / 4.90
PE.193 / 4.90
Plenum-PVC.160 / 4.06
PVDF
30.5 100.04 50 66%
28.5 93.5 51.5 66%
25.4 83.31 50 80%
25.4 83.31 50 80%
1 0.43 1.395 0.95 3.1210 1.35 4.4350 3.04 9.98100 4.33 14.21200 6.18 20.27400 8.85 29.02700 11.86 38.91900 13.55 41.751000 14.33 47.00
1 0.41 1.355 0.98 3.2110 1.32 4.3350 3.22 10.56100 4.59 15.06200 6.56 21.52400 9.42 30.89700 12.65 41.49900 14.46 47.421000 15.31 50.22
1 0.41 1.355 0.98 3.2110 1.32 4.3350 3.22 10.56100 4.59 15.06200 6.56 21.52400 9.42 30.89700 12.65 41.49900 14.46 47.421000 15.31 50.22
1 0.43 1.435 0.98 3.2210 1.39 4.5850 3.18 10.45100 4.57 15.00200 6.61 21.67400 9.62 31.54700 13.12 43.05900 15.13 49.641000 16.07 52.72
1 0.43 1.435 0.98 3.2210 1.39 4.5850 3.18 10.45100 4.57 15.00200 6.61 21.67400 9.62 31.54700 13.12 43.05900 15.13 49.641000 16.07 52.72
81
Electronics Coaxial Cable
Headend CATV Drop Cable75 Ohm Low Loss Quad Shield RG-59
Product Construction:Conductor:• 20 AWG; Silver-Plated, Copper-Covered
Steel
Insulation:• Cellular Polyethylene
Shield:• Shield #1: Bonded Aluminum-Poly Tape;
100% Nom. Coverage• Shield #2: 34 AWG Aluminum Braid;
95% Nom. Coverage• Shield #3: Dual Aluminum-Poly Tape;
100% Nom. Coverage• Shield #4: 34 AWG Aluminum Braid;
95% Nom. Coverage
Jacket:• Flame-retardant PVC
Jacket Markings:• HELIX/HITEMP P/N 395020 BROADBAND
20 AWG CATVR OR CMR 75C (UL) c(UL) – RG-59/U TYPE TRI QUAD SHIELD - MADE IN USA -XXXXXXX*
Compliances:• UL Standard 444 and NEC Article 800 Type
CMR and NEC Article 820 Type CATVR• c(UL) meets CSA Communications Cable
Type CMG• Passes UL-1666 Riser Tray Cable and CSA
FT-4 Flame Test
Cable Weight:• 33.5 Lbs/Kft Nom. (15.2 Kg)
Packaging and Jacket Colors:• Please consult Customer Service for
packaging and color options
*XXXXXXX: Indicates sequential footage marking every 2 feet
CATALOGNUMBER COND. DIAMETER NOM.
INSULATION& O.D.
JACKET& O.D. RATINGS
395020 032" (0.81mm) .144" (3.66mm) .273" (6.93mm) CMR CATVR
FREQUENCY(MHz)
dB/100 ft. (MAX.) Db/100 m. (MAX.)
1 0.46 1.513.6 0.73 2.395 0.86 2.8210 1.22 3.9950 1.95 6.4155 2.05 6.73
71.5 2.27 7.4683 2.45 8.04
88.5 2.53 8.30100 2.69 8.82135 3.12 10.25180 3.53 11.59187 3.60 11.81200 3.70 12.14211 3.80 12.47250 4.10 13.45270 4.26 13.98300 4.45 14.60350 4.80 15.75360 4.87 15.97375 4.95 16.24400 5.10 16.73450 5.40 17.72500 5.70 18.70540 5.90 19.34550 5.95 19.52600 6.20 20.34650 6.45 21.16700 6.73 22.09750 6.97 22.87862 7.47 24.52900 7.66 25.131000 8.12 26.641450 9.78 32.081500 9.94 32.631800 10.89 35.742250 12.18 39.963000 14.06 46.14
Attenuation
Electrical CharacteristicsConductor DCRShield DCRCapacitanceImpedanceVelocity of PropagationSRL
25.83 Ohms/Kft Nom.1.15 Ohm/Kft Max.16.2 pF/Ft Nom.75.0 +/- 3 Ohms85% Nom.20dB Min. (1MHz – 1GHz)
82
Coaxial Cable Electronics
FREQUENCY(MHz)
dB/100 ft. (MAX.) Db/100 m. (MAX.)
1 0.46 1.513.6 0.73 2.395 0.86 2.8210 1.22 3.9950 1.95 6.4155 2.05 6.73
71.5 2.27 7.4683 2.45 8.04
88.5 2.53 8.30100 2.69 8.82135 3.12 10.25180 3.53 11.59187 3.60 11.81200 3.70 12.14211 3.80 12.47250 4.10 13.45270 4.26 13.98300 4.45 14.60350 4.80 15.75360 4.87 15.97375 4.95 16.24400 5.10 16.73450 5.40 17.72500 5.70 18.70540 5.90 19.34550 5.95 19.52600 6.20 20.34650 6.45 21.16700 6.73 22.09750 6.97 22.87862 7.47 24.52900 7.66 25.131000 8.12 26.641450 9.78 32.081500 9.94 32.631800 10.89 35.742250 12.18 39.963000 14.06 46.14
Attenuation
Headend Tinned Copper Drop Cable75 Ohm Low Loss Tri-Shield RG-59
Product Construction:Conductor:• 20 AWG; Silver-Plated, Copper-Covered
Steel
Insulation:• Cellular Polyethylene
Shield:• Shield #1: Bonded Aluminum-Poly Tape;
100% Nom. Coverage• Shield #2: 34 AWG Tinned Copper Braid;
95% Nom. Coverage• Shield #3: 34 AWG Tinned Copper Braid;
95% Nom. Coverage
Jacket:• Flame-retardant PVC
Jacket Markings:• HELIX/HITEMP P/N 395016 BROADBAND
20 AWG CATVR OR CMR 75C (UL) c(UL) – RG-59/U TYPE TRI-SHIELD - MADE IN USA-XXXXXXX*
Compliances:• UL Standard 444 and NEC Article 800 Type
CMR) and NEC Article 820 Type CATVR• c(UL) meets CSA Communications Cable
Type CMG• Passes UL-1666 Riser Tray Cable and CSA
FT-4 Flame Test
Cable Weight:• 54.0 Lbs/Kft Nom. (24.5 Kg)
Packaging and Jacket Colors:• Please consult Customer Service for
packaging and color options
*XXXXXXX: Indicates sequential footage marking every 2 feet
395016 .032" (0.81mm) .144" (3.66mm) .270" (6.86mm) CMR
Electrical CharacteristicsConductor DCRShield DCRCapacitanceImpedanceVelocity of PropagationSRL
25.83 Ohms/Kft Nom.1.15 Ohm/Kft Max.16.2 pF/Ft Nom.75.0 +/- 3 Ohms85% Nom.20dB Min. (1MHz – 1GHz)
CATALOGNUMBER COND. DIAMETER NOM.
INSULATION& O.D.
JACKET& O.D. RATINGS
83
Electronics Coaxial Cable
RG 213, RG 214, RG 174 Cable50 Ohm LAN & Data Transmission Computer Cables
Part No.& SafetyRatings
Cond.Size/Type
& DCR
InsulationType Nom.O.D. in/mm
Shield Type &DCR/KFt
Jacket & Nom.Dia. in/mm
Nom.Imp.Ohm
Nom.Vel. ofProp.
NominalCapacitance
pF/ft pF/m
Nominal Attenuation
MHz dB/ dB/100FT 100m
397010RG-213/U
MIL-C-17/163AUL-CMX c(UL)
AWM-135475˚C / 300V
397011RG-214/U
MIL-C-17/164UL-CMX c(UL)
AWM-135475˚C / 300V
395027RG-174/U
AWM-135475˚C / 300V
13 AWG(7/.0296)
(.089)Stranded BC1.70 / 5.58
13 AWG(7/.0296)
(.089)Stranded SPCSilver-Plated
Copper1.70 / 5.58
26 AWG(7/34)
Stranded BareCopper Covered
Steel93.0 / 305.04
Solid PE.285 / 7.24
Solid PE.285 / 7.24
Solid PE.059 / .139
Braid Shield97% BC
1.20 / 3.94
Dual BraidShield
97% SPCSilver-Plated
Copper.74 / 2.43
Braid Shield88% TC
10.7 / 35.09
Non-Contaminating
PVC0.405 / 10.29
Non-Contaminating
PVC0.425 / 10.79
Flame-RetardantPVC
.110 / 2.82
30.8 101.02 50 66%
30.8 101.02 50 66%
30.8 101.02 50 66%
1 0.16 53.075 0.53 STS310 1.18 10050 1.90 DS4100 4.03 200200 5.94 0.45400 8.79 0.54700 13.35 1.02900 18.37 1.101000 21.22 1.532000 22.57 2.024000 34.24 2.33
1 0.16 0.535 0.36 1.1810 0.58 1.9050 1.23 4.03100 1.81 5.94200 2.68 8.79400 4.07 13.35700 5.60 18.37900 6.47 21.221000 6.88 22.572000 10.44 34.244000 16.18 53.073
1 1.90 6.25 2.32 7.6010 3.30 11.050 5.80 19.0100 8.40 27.60200 12.50 41.0400 19.0 62.3700 27.0 89.0900 31.0 102.01000 34.0 116.01
84
85
http://www.generalcable.com/NorthAmerica/NA_EL_ProdBulletins.htm
86
Electronics
Index PageMulti-Conductor,Unshielded, Non-Plenum 87Multi-Conductor,Shielded, Non-Plenum 88Multi-Conductor, Unshielded, Plenum 89Multi-Conductor, Shielded, Plenum 90Multi-Conductor, Unshielded,Plenum, PVDF Jacketed 91Multi-Conductor, Shielded,Plenum, PVDF Jacketed 92Mid-Capacitance, Unshielded, Non-Plenum 93Mid-Capacitance, Shielded, Non-Plenum 94Mid-Capacitance, Unshielded, Plenum 95Mid-Capacitance, Shielded, Plenum 96
Fire alarm systems haveexpanded from a rather simpleand unsophisticated businessconfigured upon large, electro-mechanical devices to onerelying upon the most moderntechnologies of microprocessorand chip technology.
More and more end users—industrial, commercial as wellas consumer—are relying uponthese emerging systems toprotect both property and life.These systems are only asgood as their weakestcomponent, whether thatcomponent be a processor orinterconnecting wire and cable.
It is General Cable’s charterthat all products supplied foruse in these and any othersystems shall be constructedof only the finest availablematerials, and provide theservice and assurance that theend user not only needs, butrequires.
Aside from the qualitymaterials used in thesedesigns, specifiers and endusers of Carol® Brand wire andcable products have come toexpect that these cables areregistered and certified with
the leading regulatory agenciessuch as UnderwritersLaboratories … and we haven’tlet you down!
These designs have proventhemselves in the area of firesystem security over time; allare fabricated with solid, barecopper conductors andinsulations and jackets ofpremium-grade PVC. Offeredboth with and without shields,the former to protect thesecritical circuits from noise,these cables will provide thelatest in available technologyfor the system installer andcontractor.
General Cable Carol® Brandproducts are convenientlypackaged in 1000' or 500'Iengths to assist the installer.
Fire Alarm/Life Safety Cable 6
87
Electronics Fire Alarm/Life Safety Cable
Multi-Conductor, Unshielded, Non-PlenumNEC Type FPLR
Product Construction:Conductor:
• 22 thru 12 AWG fully annealed solid barecopper per ASTM B-3
Insulation:• Premium-grade, coIor-coded S-R PVC• Color Code: See chart below
Jacket:• Premium-grade, red PVC• Suitable for use from 20°C to + 75°C• Round constructions have sequential
footage markings to facilitate installation• Includes ripcord on round constructions
Applications:• Wiring of fire alarms• Smoke detectors• Voice communications• Burglar alarms• Fire protective circuits• Suggested voltage rating: 300 volts
Compliances:• UL Type FPLR (UL: 75°C, 300V)• NEC Article 760• California State Fire Marshall Approved• Designed to Meet UL 1666 Flame Test
Packaging:• Please contact Customer Service for
packaging and color options
CATALOGNUMBER
NO. OF COND.
E2402SE2404SE2406S
2
2
2
AWGSIZE
18
16
14
COND.STRAND.
Solid
Solid
Solid
0.032
0.032
0.032
0.105 x 0.210
0.115 x 0.230
0.126 x 0.252
2.67 x 5.33
2.92 x 5.84
3.20 x 6.40
0.81
0.81
0.81
NOM. INSULATIONTHICKNESS NOMINAL O.D.
INCHES mm INCHES mm
DUPLEX PARALLEL, RIBBED FOR POLARITY
Color Code Chart
123456 7 8
NO. OF COND. COLOR
BlackRedBrownBlueOrangeYellowVioletGray
22 AWG CONDUCTORS
CATALOGNUMBER
NO. OFCOND.
AWGSIZE
COND.STRAND.
NOM. INSULATIONTHICKNESS
NOM. JACKET WALL NOMINAL O.D.
INCHES mm INCHES mm INCHES mm
E1482SE1484SE1486S
2
4
6
22
22
22
Solid
Solid
Solid
0.010
0.010
0.010
0.25
0.25
0.25
0.015
0.015
0.015
0.38
0.38
0.38
0.121
0.140
0.168
3.07
3.56
4.27
18 AWG CONDUCTORSE1502SE1503SE1504SE1505S E1506SE1508S
2
3
4
5
6
8
18
18
18
18
18
18
Solid
Solid
Solid
Solid
Solid
Solid
0.010
0.010
0.010
0.010
0.010
0.010
0.25
0.25
0.25
0.25
0.25
0.25
0.015
0.015
0.015
0.015
0.015
0.015
0.38
0.38
0.38
0.38
0.38
0.38
0.150
0.160
0.175
0.193
0.210
0.230
3.81
4.06
4.45
4.90
5.33
5.84
16 AWG CONDUCTORSE1512SE1514S
2
4
16
16
Solid
Solid
0.010
0.010
0.25
0.25
0.015
0.015
0.38
0.38
0.172
0.202
4.37
5.13
14 AWG CONDUCTORSE1522SE1524S
2
4
14
14
Solid
Solid
0.013
0.013
0.33
0.33
0.015
0.015
0.38
0.38
0.210
0.248
5.33
6.30
12 AWG CONDUCTORSE1532SE1534S
2
4
12
12
Solid
Solid
0.013
0.013
0.33
0.33
0.015
0.015
0.38
0.38
0.244
0.288
6.20
7.32
88
Fire Alarm/Life Safety Cable Electronics
Product Construction:Conductor:
• 22 thru 12 AWG fully annealed solid barecopper per ASTM B-3
Insulation:• Premium-grade, coIor-coded S-R PVC• Color Code: See chart below
Shield:• Overall Flexfoil® polyester supported
aluminum foil• Stranded tinned copper drain wire
Jacket:• Premium-grade, red PVC• Suitable for use from 20°C to + 75°C• Sequential footage markings to facilitate
installation• Includes ripcord
Applications:• Wiring of fire alarms• Smoke alarms• Voice communications• Burglar alarms• Fire protective circuits• Suggested voltage rating: 300 volts
Compliances:• UL Type FPLR (UL: 75°C, 300V)• NEC Article 760• California State Fire Marshall Approved• Designed to Meet UL 1666 Flame Test
Packaging:• Please contact Customer Service for
packaging and color options
Color Code Chart
123456 7 8
NO. OF COND. COLOR
BlackRedBrownBlueOrangeYellowVioletGray
22 AWG CONDUCTORS
CATALOGNUMBER
NO. OFCOND.
AWGSIZE
COND.STRAND.
NOM. INSULATIONTHICKNESS
NOM. JACKET WALL NOMINAL O.D.
INCHES mm INCHES mm INCHES mm
E2482SE2484S
2
4
22
22
Solid
Solid
0.010
0.010
0.25
0.25
0.015
0.015
0.38
0.38
0.126
0.145
3.20
3.68
18 AWG CONDUCTORSE2502SE2503SE2504SE2506SE2508S
2
3
4
6
8
18
18
18
18
18
Solid
Solid
Solid
Solid
Solid
0.010
0.010
0.010
0.010
0.010
0.25
0.25
0.25
0.25
0.25
0.015
0.015
0.015
0.015
0.015
0.38
0.38
0.38
0.38
0.38
0.158
0.165
0.183
0.216
0.235
4.01
4.19
4.65
5.49
5.97
16 AWG CONDUCTORSE2522SE2524S
2
4
16
16
Solid
Solid
0.010
0.010
0.25
0.25
0.015
0.015
0.38
0.38
0.180
0.210
4.57
5.33
14 AWG CONDUCTORSE2532SE2534S
2
4
14
14
Solid
Solid
0.013
0.013
0.33
0.33
0.015
0.015
0.38
0.38
0.218
0.253
5.54
6.43
12 AWG CONDUCTORSE2542SE2544S
2
4
12
12
Solid
Solid
0.013
0.013
0.33
0.33
0.015
0.015
0.38
0.38
0.252
0.293
6.40
7.44
Multi-Conductor, Shielded, Non-PlenumNEC Type FPLR
89
Electronics Fire Alarm/Life Safety Cable
Multi-Conductor, Unshielded, PlenumNEC Type FPLP
Product Construction:Conductor:
• 22 thru 12 AWG fully annealed solid barecopper per ASTM B3
Insulation:• Premium-grade, coIor-coded Flexguard®
PVC• Color Code: See chart below
Jacket:• Premium-grade, red Flexguard® PVC• Suitable for use from 0°C to + 75°C• Sequential footage markings to facilitate
installation• Includes ripcord
Applications:• Wiring of fire alarms• Smoke detectors• Voice communications• Burglar alarms• Fire protective circuits• Suggested voltage rating: 300 volts
Compliances:• UL Type FPLP (UL: 75°C, 300V)• NEC Article 760• California State Fire Marshall Approved• Designed to Meet UL 910 Flame Test
Packaging:• Please contact Customer Service for
packaging and color options
22 AWG CONDUCTORS
CATALOGNUMBER
NO. OFCOND.
AWGSIZE
COND.STRAND.
NOM. INSULATIONTHICKNESS
NOM. JACKET WALL NOMINAL O.D.
INCHES mm INCHES mm INCHES mm
E3482SE3484S
2
4
22
22
Solid
Solid
0.010
0.010
0.25
0.25
0.015
0.015
0.38
0.38
0.121
0.137
3.07
3.47
18 AWG CONDUCTORSE3502SE3503SE3504SE3506S
2
3
4
6
18
18
18
18
Solid
Solid
Solid
Solid
0.010
0.010
0.010
0.010
0.25
0.25
0.25
0.25
0.015
0.015
0.015
0.015
0.38
0.38
0.38
0.38
0.155
0.160
0.175
0.211
3.81
4.06
4.45
5.36
16 AWG CONDUCTORSE3512SE3514S
2
4
16
16
Solid
Solid
0.010
0.010
0.25
0.25
0.015
0.015
0.38
0.38
0.172
0.202
4.37
5.13
14 AWG CONDUCTORSE3522SE3524S
2
4
14
14
Solid
Solid
0.012
0.012
0.30
0.30
0.015
0.015
0.38
0.38
0.210
0.243
5.28
6.17
12 AWG CONDUCTORSE3532SE3534S
2
4
12
12
Solid
Solid
0.012
0.012
0.30
0.30
0.015
0.015
0.38
0.38
0.244
0.284
6.20
7.21
Color Code Chart
123456
NO. OF COND. COLOR
BlackRedBrownBlueOrangeYellow
90
Fire Alarm/Life Safety Cable Electronics
Product Construction:Conductor:
• 22 thru 12 AWG fully annealed solid barecopper per ASTM B3
Insulation:• Premium-grade, coIor-coded Flexguard®
PVC• Color Code: See chart below
Shield:• Overall Flexfoil® polyester supported
aluminum foil• Stranded tinned copper drain wire
Jacket:• Premium-grade, red Flexguard® PVC• Suitable for use from 0°C to + 75°C• Sequential footage markings to facilitate
installation• Includes ripcord
Applications:• Wiring of fire alarms• Smoke detectors• Voice communications• Burglar alarms• Fire protective circuits• Suggested voltage rating: 300 volts
Compliances:• UL Type FPLP (UL: 75°C, 300V)• NEC Article 760• California State Fire Marshall Approved• Designed to Meet UL 910 Flame Test
Packaging:• Please contact Customer Service for
packaging and color options
Color Code Chart
123456
NO. OF COND. COLOR
BlackRedBrownBlueOrangeYellow
22 AWG CONDUCTORS
CATALOGNUMBER
NO. OFCOND.
AWGSIZE
COND.STRAND.
NOM. INSULATIONTHICKNESS
NOM. JACKET WALL NOMINAL O.D.
INCHES mm INCHES mm INCHES mm
E3542S 2 22 Solid 0.010 0.25 0.015 0.38 0.126 3.20
18 AWG CONDUCTORSE3602SE3603SE3604SE3606S
2
3
4
6
18
18
18
18
Solid
Solid
Solid
Solid
0.010
0.010
0.010
0.010
0.25
0.25
0.25
0.25
0.015
0.015
0.015
0.015
0.38
0.38
0.38
0.38
0.158
0.165
0.183
0.216
4.01
4.19
4.65
5.49
16 AWG CONDUCTORSE3612SE3614S
2
4
16
16
Solid
Solid
0.010
0.010
0.25
0.25
0.015
0.015
0.38
0.38
0.180
0.210
4.57
5.33
14 AWG CONDUCTORSE3622SE3624S
2
4
14
14
Solid
Solid
0.012
0.012
0.30
0.30
0.015
0.015
0.38
0.38
0.210
0.248
5.33
6.30
12 AWG CONDUCTORSE3632SE3634S
2
4
12
12
Solid
Solid
0.012
0.012
0.30
0.30
0.015
0.015
0.38
0.38
0.252
0.300
6.40
7.62
Multi-Conductor, Shielded, PlenumNEC Type FPLP
91
Electronics Fire Alarm/Life Safety Cable
Multi-Conductor, Unshielded, PlenumNEC Type FPLP, PVDF Jacketed
Product ConstructionConductor:
• 18 thru 12 AWG fully annealed solid barecopper to ASTM B3
Insulation:• Premium-grade, coIor-coded Flexguard®
PVC• Color Code: See chart below
Jacket:• Fluoropolymer, red• Temperature Range: – 10°C to + 75°C• Includes ripcord
Applications:• Fire alarm systems• Voice communications• Smoke detectors• Pull boxes• Suggested voltage rating: 300 volts
Compliances:• UL Type FPLP (UL: 75°C, 300V)• NEC Article 760• California State Fire Marshall Approved• Designed to Meet UL 910 Flame Test
Features:• Abrasion-, chemical- and water-resistant
jacket• Sequentially footage marked
Packaging:• Please contact Customer Service for
packaging and color options
CATALOGNUMBER
NO. OFCOND.
AWGSIZE
COND.STRAND.
NOM. INSULATIONTHICKNESS
INCHES
C3200C3201C3210C3211C3220C3223C3224C3225
2
4
2
4
2
4
2
4
18
18
16
16
14
14
12
12
Solid
Solid
Solid
Solid
Solid
Solid
Solid
Solid
mm
0.010
0.010
0.010
0.010
0.013
0.013
0.013
0.013
0.23
0.23
0.23
0.23
0.31
0.31
0.31
0.31
NOM. JACKETTHICKNESS
INCHES mm
0.010
0.010
0.010
0.010
0.010
0.010
0.010
0.010
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
NOMINAL O.D.
NOM.* C-C CAP.pF/ftINCHES mm
0.140
0.156
0.133
0.186
0.170
0.224
0.194
0.261
3.56
3.96
3.38
4.72
4.32
5.69
4.93
6.63
29.0
29.0
31.0
31.0
31.0
31.0
35.0
35.0*Capacitance between conductors
Color Code Chart
1234
NO. OF COND. COLOR
BlackRedBrownBlue
92
Fire Alarm/Life Safety Cable Electronics
Product ConstructionConductor:
• 18 thru 12 AWG fully annealed solid barecopper per ASTM B3
Insulation:• Premium-grade, coIor-coded Flexguard®
PVC• Color Code: See chart below
Shield:• 100% Flexfoil® aluminum/polyester foil,
25% overlap, minimum• Stranded tinned copper drain wire
Jacket:• Fluoropolymer, red• Temperature Range: – 10°C to + 75°C• Includes ripcord
Applications:• Fire alarm systems• Voice communications• Smoke detectors• Pull boxes• Suggested voltage rating: 300 volts
Compliances:• UL Type FPLP (UL: 75°C, 300V)• NEC Article 760• California State Fire Marshall Approved
Features:• Abrasion-, chemical-resistant jacket• Sequentially footage marked
Packaging:• Please contact Customer Service for
packaging and color options
C3260C3261C3270C3271C3280C3284C3282C3283
2
4
2
4
2
4
2
4
18
18
16
16
14
14
12
12
Solid
Solid
Solid
Solid
Solid
Solid
Solid
Solid
0.010
0.010
0.010
0.010
0.013
0.013
0.013
0.013
0.25
0.25
0.25
0.25
0.33
0.33
0.33
0.33
0.010
0.010
0.010
0.010
0.010
0.010
0.010
0.010
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.149
0.168
0.169
0.194
0.214
0.245
0.234
0.284
3.78
4.27
4.29
4.93
5.44
6.22
5.94
7.21
50.5
44.5
58.0
50.0
55.5
48.0
65.0
55.0
90.8
80.0
104.0
90.0
100.0
87.0
116.0
99.0*A - Capacitance between conductors*B - Capacitance between one conductor and other conductors connected to shield
Color Code Chart
1234
NO. OF COND. COLOR
BlackRedBrownBlue
CATALOGNUMBER
NO. OFCOND.
AWGSIZE
COND.STRAND.
NOM. INSULATION THICKNESS
INCHES mm
NOM. JACKET
THICKNESSINCHES mm
NOMINAL O.D.INCHES mm
NOMINAL CAP.*pF/ft
A B
Multi-Conductor, Shielded, PlenumNEC Type FPLP, PVDF Jacketed
93
Electronics Fire Alarm/Life Safety Cable
Mid-Capacitance, Unshielded, Non-PlenumNEC Type FPL for Microprocessor-Controlled Systems
Product Construction:Conductor:
• 18 thru 12 AWG fully annealed solid barecopper per ASTM B3
Insulation:• Premium-grade, coIor-coded
polypropylene• Color Code: See chart below
Jacket:• PVC, red• Temperature Range: – 20°C to + 60°C
Applications:• Addressable fire alarm systems• Fire alarm systems• Voice communications• Smoke detectors• Pull boxes• Suggested voltage rating: 300 volts
Compliances:• UL Type FPL (UL: 60°C, 300V)• NEC Article 760• California State Fire Marshall Approved• Passes UL 70,000 BTU Vertical Tray
Flame Test
Features:• Red PVC jacket for easy critical circuit
identification
Packaging:• Please contact Customer Service for
packaging and color options
CATALOGNUMBER
NO. OFCOND.
AWGSIZE
COND.STRAND.
NOM. INSULATIONTHICKNESS
INCHES
C0471C0485C0473C0486C0491C0492
2
4
2
4
2
2
18
18
16
16
14
12
Solid
Solid
Solid
Solid
Solid
Solid
mm
0.014
0.014
0.016
0.016
0.018
0.020
0.36
0.36
0.41
0.41
0.46
0.51
NOM. JACKETTHICKNESS
INCHES mm
0.020
0.020
0.020
0.020
0.020
0.020
0.51
0.51
0.51
0.51
0.51
0.51
NOMINAL O.D.
NOM.* C-C CAP.pF/ftINCHES mm
0.177
0.205
0.206
0.241
0.240
0.282
4.50
5.21
5.23
6.12
6.10
7.16
16.5
16.5
17.5
17.5
18.0
19.0*Capacitance between conductors
Color Code Chart
1234
NO. OF COND. COLOR
BlackRedBrownBlue
94
Fire Alarm/Life Safety Cable Electronics
Product Construction:Conductor:
• 18 thru 12 AWG fully annealed solid barecopper per ASTM B3
Insulation:• Premium-grade, coIor-coded
polypropylene• Color Code: See chart below
Shield:• 100% Flexfoil® aluminum/polyester,
25% overlap, minimum• Stranded tinned copper drain wire
Jacket:• PVC, red• Temperature Range: 0°C to + 60°C
Applications:• Addressable fire alarm systems• Fire alarm systems• Voice communications• Smoke detectors• Pull boxes• Suggested voltage rating: 300 volts
Compliances:• UL Type FPL (UL:60°C, 300V)• NEC Article 760• California State Fire Marshall Approved• Passes UL 70,000 BTU Vertical Tray
Flame Test
Features:• Red PVC jacket for easy critical circuit
identification
Packaging:• Please contact Customer Service for
packaging and color options
CATALOGNUMBER
C0472C0494C0474C0495C0475C0496C0476C0497
2
4
2
4
2
4
2
4
NO. OFCOND.
AWGSIZE
COND.STRAND.
NOM. INSULATION THICKNESS
INCHES mm
NOM. JACKET
THICKNESSINCHES mm
NOMINAL O.D.INCHES mm
NOMINAL CAP.*pF/ft
A B
18
18
16
16
14
14
12
12
Solid
Solid
Solid
Solid
Solid
Solid
Solid
Solid
0.014
0.014
0.016
0.016
0.018
0.018
0.020
0.020
0.36
0.36
0.41
0.41
0.46
0.46
0.51
0.51
0.020
0.020
0.020
0.020
0.020
0.020
0.020
0.020
0.51
0.51
0.51
0.51
0.51
0.51
0.51
0.51
0.182
0.210
0.214
0.246
0.245
0.287
0.287
0.337
4.88
5.33
5.44
6.25
6.22
7.29
7.29
8.56
27.0
24.5
29.0
26.0
31.0
27.5
33.0
29.0
49.0
44.0
52.0
46.5
55.5
49.5
60.0
52.5*A - Capacitance between conductors*B - Capacitance between one conductor and other conductors connected to shield
Color Code Chart
1234
NO. OF COND. COLOR
BlackRedBrownBlue
Mid-Capacitance, Shielded, Non-PlenumNEC Type FPL for Microprocessor-Controlled Systems
95
Electronics Fire Alarm/Life Safety Cable
Mid-Capacitance, Unshielded, PlenumNEC Type FPLP for Microprocessor-Controlled Systems
Product Construction:Conductor:
• 18 thru 12 AWG fully annealed solid barecopper per ASTM B3
Insulation:• Premium-grade, coIor-coded
Fluoropolymer• Color Code: See chart below
Jacket:• Premium-grade, red Flexguard® PVC• Temperature Range: 0°C to + 75°C• Includes ripcord
Applications:• Addressable fire alarm systems• Fire alarm systems• Voice communications• Smoke detectors• Pull boxes• Suggested voltage rating: 300 volts
Compliances:• UL Type FPLP (UL: 75°C, 300V)• NEC Article 760• California State Fire Marshall Approved• Designed to Meet UL 910 Flame Test
Features:• Red PVC jacket for easy critical circuit
identification
Packaging:• Please contact Customer Service for
packaging and color options
CATALOGNUMBER
NO. OFCOND.
AWGSIZE
COND.STRAND.
NOM. INSULATIONTHICKNESS
INCHES
C3240C3242C3241C3243C3244C3245C3246C3247
2
4
2
4
2
4
2
4
18
18
16
16
14
14
12
12
Solid
Solid
Solid
Solid
Solid
Solid
Solid
Solid
mm
0.014
0.014
0.016
0.016
0.018
0.018
0.020
0.020
0.36
0.36
0.41
0.41
0.46
0.46
0.51
0.51
NOM. JACKETTHICKNESS
INCHES mm
0.015
0.015
0.015
0.015
0.020
0.020
0.020
0.020
0.38
0.38
0.38
0.38
0.51
0.51
0.51
0.51
NOMINAL O.D.
NOM.* C-C CAP.pF/ftINCHES mm
0.172
0.195
0.196
0.231
0.242
0.286
0.282
0.333
4.37
4.95
4.98
5.87
6.15
7.26
7.16
8.45
19.0
19.0
20.0
20.0
20.0
20.0
22.0
22.0*Capacitance between conductors
Color Code Chart
1234
NO. OF COND. COLOR
BlackRedBrownBlue
96
Fire Alarm/Life Safety Cable Electronics
Product ConstructionConductor:
• 18 thru 12 AWG fully annealed solid barecopper per ASTM B3
Insulation:• Premium-grade, coIor-coded
Fluoropolymer• Color Code: See chart below
Shield:• 100% Flexfoil® aluminum/polyester foil,
25% overlap, minimum• Stranded tinned copper drain wire
Jacket:• Premium-grade, red Flexguard® PVC• Temperature Range: 0°C to + 75°C• Includes ripcord
Applications:• Addressable fire alarm systems• Fire alarm systems• Voice communications• Smoke detectors• Pull boxes• Suggested voltage rating: 300 volts
Compliances:• UL Type FPLP (UL: 75°C, 300V)• NEC Article 760• California State Fire Marshall Approved• Designed to Meet UL 910 Flame Test
Features:• Red PVC jacket for easy critical circuit
identification
Packaging:• Please contact Customer Service for
packaging and color options
Color Code Chart
1234
NO. OF COND. COLOR
BlackRedBrownBlue
Mid-Capacitance, Shielded, PlenumNEC Type FPLP for Microprocessor-Controlled Systems
C3167C3170C3168C3171C3172C3173C3174C3175
2
4
2
4
2
4
2
4
18
18
16
16
14
14
12
12
Solid
Solid
Solid
Solid
Solid
Solid
Solid
Solid
0.014
0.014
0.016
0.016
0.018
0.018
0.020
0.020
0.36
0.36
0.41
0.41
0.46
0.46
0.51
0.51
0.015
0.015
0.015
0.015
0.020
0.020
0.020
0.020
0.38
0.38
0.38
0.38
0.51
0.51
0.51
0.51
0.172
0.202
0.203
0.238
0.247
0.289
0.289
0.340
4.37
5.13
5.16
6.05
6.27
7.34
7.34
8.64
31.0
28.0
33.0
29.0
35.0
30.0
38.0
33.0
56.0
50.0
59.0
53.0
63.0
56.0
68.0
60.0*A - Capacitance between conductors*B - Capacitance between one conductor and other conductors connected to shield
CATALOGNUMBER
NO. OFCOND.
AWGSIZE
COND.STRAND.
NOM. INSULATION THICKNESS
INCHES mm
NOM. JACKET
THICKNESSINCHES mm
NOMINAL O.D.INCHES mm
NOMINAL CAP.*pF/ft
A B
97
Electronics
Sound, Alarm & Security Cable 7
Index Page
Multi-Conductor, Unshielded, Riser 98
Multi-Conductor, Shielded, Riser 99
Multi-Conductor, Unshielded, Plenum 100
Multi-Conductor, Shielded, Plenum 101
Antenna Rotor 102
Telephone Station/Intercom & Speaker/Burglar Alarm 103
Low-Voltage Sprinkler Wire 104
Thermostat Wire Type LVT 105
Thermostat Wire Type CL2 106
Thermostat Wire, Unjacketed 107
The sound and securityindustry in the United Stateshas grown from a simple andunsophisticated business,begun some 45 years ago, toone which has developedtechnology to the degree thatspecialized wires and cablesare now much in demand.
No longer are the securityand sound industriescharacterized by largeelectromechanical relays andlarge contactors; today thesecircuits incorporate the latest in microprocessors and solidstate devices to not onlyimprove functionality but alsoto guarantee performance.
As a major wire producer,our role is to ensure that thewires and cables that go intothese systems are as reliableas the other components…the net result is a fullyintegrated system which willprovide peace of mind to thesystem user.
Also in this section areGeneral Cable’s Carol® Brandwire and cable designs suitablefor a variety of applications,both in industrial andcommercial environments,
including telephone systems,intercoms, burglar alarms,business machines andthermostats.
Aside from the qualitymaterials used in thesedesigns, specifiers and usersof Carol® Brand wire and cableproducts have come to expectthat these cables are registeredand certified with the leadingregulatory agencies such asUnderwriters Laboratories…and we haven’t let you down!
Carol® Brand designs haveproven themselves in the areaof sound and security overtime; most are fabricated withsolid or stranded, bare copperconductors with insulationsand jackets of premium gradesof PVC. We offer both paralleland cabled designs both withand without shields. Sequentialfootage markings on thejackets are offered on allproducts.
General Cable Carol® Brandproducts are convenientlypackaged in 1000' or 500'Iengths to assist the installer.
98
Sound, Alarm & Security Cable Electronics
CATALOGNUMBER
NO. OFCOND.
AWGSIZE
COND.STRAND.
NOM. INSULATIONTHICKNESS
NOM. JACKET WALL NOMINAL O.D.
INCHES mm INCHES mm INCHES mm
E1000SE1001SE1002SE1003SE1004SE1006SE1008SE1010SE1012S
2
4
2
3
4
6
8
10
12
22
22
22
22
22
22
22
22
22
Solid
Solid
7/30
7/30
7/30
7/30
7/30
7/30
7/30
0.007
0.007
0.008
0.008
0.008
0.008
0.008
0.008
0.008
0.20
0.20
0.20
0.20
0.20
0.20
0.20
0.20
0.20
0.015
0.015
0.015
0.015
0.015
0.015
0.015
0.015
0.015
0.38
0.38
0.38
0.38
0.38
0.38
0.38
0.38
0.38
0.118
0.126
0.122
0.129
0.156
0.164
0.180
0.212
0.219
3.00
3.20
3.10
3.28
3.96
4.17
4.57
5.38
5.56
22 AWG CONDUCTORS
E1022SE1023SE1024S
2
3
4
20
20
20
7/28
7/28
7/28
0.008
0.008
0.008
0.20
0.20
0.20
0.015
0.015
0.015
0.38
0.38
0.38
0.134
0.134
0.142
3.40
3.40
3.60
20 AWG CONDUCTORS
18 AWG CONDUCTORS
E1052S*E1054S*
2
4
14
14
19/.0147
19/.0147
0.013
0.013
0.33
0.33
0.015
0.015
0.38
0.38
0.224
0.264
5.69
6.71
14 AWG CONDUCTORS
*NEC CL3R only
E1030SE1032SE1033SE1034SE1036SE1038SE1040SE1041S
2
2
3
4
6
8
10
12
18
18
18
18
18
18
18
18
Solid
7/26
7/26
7/26
7/26
7/26
7/26
7/26
0.009
0.009
0.009
0.009
0.009
0.009
0.009
0.009
0.23
0.23
0.23
0.23
0.23
0.23
0.23
0.23
0.015
0.015
0.015
0.015
0.015
0.015
0.015
0.015
0.38
0.38
0.38
0.38
0.38
0.38
0.38
0.38
0.144
0.156
0.166
0.187
0.225
0.245
0.282
0.291
3.66
3.96
4.22
4.75
5.72
6.22
7.16
7.39
E1042SE1043SE1044S
2
3
4
16
16
16
19/.0117
19/.0117
19/.0117
0.009
0.009
0.009
0.25
0.25
0.25
0.015
0.015
0.015
0.38
0.38
0.38
0.178
0.193
0.209
4.52
4.90
5.31
16 AWG CONDUCTORS
E1062S*E1064S*
2
4
12
12
19/.0185
19/.0185
0.013
0.013
0.33
0.33
0.015
0.015
0.38
0.38
0.260
0.307
6.60
7.80
12 AWG CONDUCTORS
Product Construction:Conductor:
• Stranded or solid bare copper per ASTM B-3, B-8 and B-286
Insulation:• Premium-grade, coIor-coded S-R PVC• Color Code: See chart below
Jacket:• Premium-grade, gray PVC• Sequential footage markings to facilitate
installation• Suitable for use from –20°C to +75°C• Includes ripcord
Applications:• Power-limited control circuits• Wiring of the following systems:
IntercomSecurityAudioBackground music
• Suggested voltage rating: 300 volts
Compliances:• NEC Article 725 Type CL3R
(UL: 75°C, 150V)• NEC Article 800 Type CMR
(UL: 75°C, 300V)• California State Fire Marshall Approved
Packaging:• Please contact Customer Service for
packaging and color options
Multi-Conductor, Unshielded, RiserNEC Type CMR and/or CL3R
Color Code Chart
123456
NO. OFCOND. COLOR
BlackRedWhiteGreenBrownBlue
789
101112
NO. OFCOND. COLOR
OrangeYellowVioletGrayPinkTan
99
Electronics Sound, Alarm & Security Cable
Product Construction:Conductor:
• Stranded or solid bare copper per ASTM B-3, B-8 and B-286
Insulation:• Premium-grade, coIor-coded S-R PVC• Color Code: See chart below
Shield:• Overall Flexfoil® polyester supported
aluminum foil• Stranded tinned copper drain wire
Jacket:• Premium-grade, gray PVC• Sequential footage markings to facilitate
installation• Suitable for use from –20°C to + 75°C• Includes ripcord
Applications:• Power-limited control circuits• Wiring of the following systems:
IntercomSecurityAudioBackground music
• Suggested voltage rating: 300 volts
Compliances:• NEC Article 725 Type CL3R
(UL: 75°C,150V)• NEC Article 800 Type CMR
(UL: 75°C, 300V)• California State Fire Marshall Approved
Packaging:• Please contact Customer Service for
packaging and color options
Multi-Conductor, Shielded, RiserNEC Type CMR and/or CL3R
Color Code Chart
123456
NO. OFCOND. COLOR
BlackRedWhiteGreenBrownBlue
789
101112
NO. OFCOND. COLOR
OrangeYellowVioletGrayPinkTan
CATALOGNUMBER
NO. OFCOND.
AWGSIZE
COND.STRAND.
NOM. INSULATIONTHICKNESS
NOM. JACKET WALL NOMINAL O.D.
INCHES mm INCHES mm INCHES mm
E2022SE2023SE2024S
2
3
4
20
20
20
7/28
7/28
7/28
0.008
0.008
0.008
0.20
0.20
0.20
0.015
0.015
0.015
0.38
0.38
0.38
0.142
0.151
0.171
3.61
3.84
4.34
20 AWG CONDUCTORS
18 AWG CONDUCTORS
E2052S*E2054S*
2
4
14
14
19/.0147
19/.0147
0.013
0.013
0.33
0.33
0.015
0.015
0.38
0.38
0.245
0.269
6.22
6.83
14 AWG CONDUCTORS
* NEC CL3R only
E2030SE2032SE2033SE2034SE2036SE2038SE2040SE2041S
2
2
3
4
6
8
10
12
18
18
18
18
18
18
18
18
Solid
7/26
7/26
7/26
7/26
7/26
7/26
7/26
0.009
0.009
0.009
0.009
0.009
0.009
0.009
0.009
0.23
0.23
0.23
0.23
0.23
0.23
0.23
0.23
0.015
0.015
0.015
0.015
0.015
0.015
0.015
0.015
0.38
0.38
0.38
0.38
0.38
0.38
0.38
0.38
0.147
0.164
0.172
0.192
0.230
0.250
0.287
0.296
3.73
4.17
4.37
4.88
5.54
6.35
7.29
7.52
E2042SE2043SE2044S
2
3
4
16
16
16
19/.0117
19/.0117
19/.0117
0.010
0.010
0.010
0.25
0.25
0.25
0.015
0.015
0.015
0.38
0.38
0.38
0.189
0.198
0.219
4.80
5.03
5.56
16 AWG CONDUCTORS
E2062S*E2064S*
2
4
12
12
19/.0185
19/.0185
0.013
0.013
0.33
0.33
0.015
0.015
0.38
0.38
0.281
0.312
7.14
7.92
12 AWG CONDUCTORS
22 AWG CONDUCTORSE2000SE2002SE2003SE2004SE2006SE2008SE2010SE2012S
2
2
3
4
6
8
10
12
22
22
22
22
22
22
22
22
Solid
7/30
7/30
7/30
7/30
7/30
7/30
7/30
0.008
0.008
0.008
0.008
0.008
0.008
0.008
0.008
0.20
0.20
0.20
0.20
0.20
0.20
0.20
0.20
0.015
0.015
0.015
0.015
0.015
0.015
0.015
0.015
0.38
0.38
0.38
0.38
0.38
0.38
0.38
0.38
0.117
0.132
0.135
0.147
0.173
0.195
0.218
0.225
2.97
3.35
3.43
3.73
4.39
4.95
5.54
5.72
100
Sound, Alarm & Security Cable Electronics
Product Construction:Conductor:
• Stranded or solid bare copper per ASTM B-3, B-8 and B-286
Insulation:• Premium-grade, coIor-coded Flexguard®
PVC• Color Code: See chart below
Jacket:• Premium-grade natural Flexguard® PVC• Sequential footage markings to facilitate
installation• Suitable for use from 0°C to +75°C• Ripcord available—consult Customer
Service for details
Applications:• Power-limited control circuits• Wiring of the following systems:
IntercomSecurityAudioBackground music
• Suggested voltage rating: 300 volts
Compliances:• NEC Article 725 Type CL3P
(UL: 75°C, 150V)• NEC Article 800 Type CMP
(UL: 75°C, 300V)• Designed to Meet UL 910 Flame Test• California State Fire Marshall Approved
Packaging:• Please contact Customer Service for
packaging and color options
Multi-Conductor, Unshielded, PlenumNEC Type CMP and/or CL3P
mmCATALOGNUMBER
NO. OFCOND.
AWGSIZE
COND.STRAND.
NOM. INSULATIONTHICKNESS
NOM. JACKET WALL NOMINAL O.D.
INCHES mm INCHES mm INCHES mm
E3022SE3023SE3024S
2
3
4
20
20
20
7/28
7/28
7/28
0.008
0.009
0.009
0.20
0.23
0.23
0.015
0.015
0.015
0.38
0.38
0.38
0.138
0.146
0.161
3.51
3.71
4.09
20 AWG CONDUCTORS
18 AWG CONDUCTORS
E3052S*E3054S*
2
4
14
14
19/.0147
19/.0147
0.011
0.011
0.28
0.28
0.015
0.015
0.38
0.38
0.216
0.255
5.49
6.48
14 AWG CONDUCTORS
* NEC CL3P only
E3030SE3032SE3033SE3034SE3036SE3038S
2
2
3
4
6
8
18
18
18
18
18
18
Solid
7/26
7/26
7/26
7/26
7/26
0.008
0.008
0.008
0.008
0.008
0.008
0.20
0.20
0.20
0.20
0.20
0.20
0.015
0.015
0.015
0.015
0.015
0.015
0.38
0.38
0.38
0.38
0.38
0.38
0.142
0.156
0.166
0.187
0.216
0.235
3.61
3.96
4.22
4.75
5.49
5.97
E3042SE3043SE3044S
2
3
4
16
16
16
19/.0117
19/.0117
19/.0117
0.008
0.008
0.008
0.20
0.20
0.20
0.015
0.015
0.015
0.38
0.38
0.38
0.174
0.185
0.204
4.42
4.70
5.18
16 AWG CONDUCTORS
E3062S*E3064S*
2
4
12
12
19/.0185
19/.0185
0.011
0.011
0.28
0.28
0.015
0.015
0.38
0.38
0.252
0.298
6.40
7.57
12 AWG CONDUCTORS
22 AWG CONDUCTORSE3000SE3001SE3002SE3003SE3004SE3006SE3008SE3010SE3012S
2
4
2
3
4
6
8
10
12
22
22
22
22
22
22
22
22
22
Solid
Solid
7/30
7/30
7/30
7/30
7/30
7/30
7/30
0.007
0.007
0.008
0.008
0.008
0.008
0.008
0.008
0.008
0.18
0.18
0.20
0.20
0.20
0.20
0.20
0.20
0.20
0.015
0.015
0.015
0.015
0.015
0.015
0.015
0.015
0.015
0.38
0.38
0.38
0.38
0.38
0.38
0.38
0.38
0.38
0.108
0.124
0.120
0.127
0.139
0.164
0.178
0.194
0.211
2.74
3.15
3.05
3.23
3.53
4.17
4.52
4.92
5.36
Color Code Chart
123456 7 8
NO. OF COND. COLOR
BlackRedWhiteGreenBrownBlueOrangeYellow
101
Electronics Sound, Alarm & Security Cable
Multi-Conductor, Shielded, PlenumNEC Type CMP and/or CL3P
Product Construction:Conductor:
• Stranded or solid bare copper perASTM B-3, B-8 and B-286
Insulation:• Premium-grade, coIor-coded Flexguard®
PVC
Shield:• Overall Flexfoil® polyester supported
aluminum foil• Stranded tinned copper drain wire
Jacket:• Premium-grade natural Flexguard® PVC• Sequential footage markings to facilitate
installation• Suitable for use from 0°C to + 75°C• Ripcord available—consult Customer
Service for details
Applications:• Power-limited control circuits• Wiring of the following systems:
IntercomSecurityAudioBackground music
• Suggested voltage rating: 300 volts
Compliances:• NEC Article 725 Type CL3P
(UL: 75°C, 150V)• NEC Article 800 Type CMP
(UL: 75°C, 300V)• Designed to Meet UL 910 Flame Test• California State Fire Marshall Approved
Packaging:• Please contact Customer Service for
packaging and color options
CATALOGNUMBER
NO. OFCOND.
AWGSIZE
COND.STRAND.
NOM. INSULATIONTHICKNESS
NOM. JACKET WALL NOMINAL O.D.
INCHES mm INCHES mm INCHES mm
E2122SE2123SE2124S
2
3
4
20
20
20
7/28
7/28
7/28
0.009
0.009
0.009
0.23
0.23
0.23
0.015
0.015
0.015
0.38
0.38
0.38
0.143
0.151
0.166
3.63
3.84
4.22
20 AWG CONDUCTORS
18 AWG CONDUCTORS
E2252S*E2254S*
2
4
14
14
19/.0147
19/.0147
0.008
0.008
0.20
0.20
0.015
0.015
0.38
0.38
0.207
0.260
5.26
6.60
14 AWG CONDUCTORS
* NEC CL3P only
E2200SE2202SE2203SE2204SE2206SE2208S
2
2
3
4
6
8
18
18
18
18
18
18
Solid
7/26
7/26
7/26
7/26
7/26
0.008
0.008
0.008
0.008
0.009
0.009
0.20
0.20
0.20
0.20
0.23
0.23
0.015
0.015
0.015
0.015
0.015
0.015
0.38
0.38
0.38
0.38
0.38
0.38
0.148
0.164
0.169
0.185
0.231
0.252
3.76
4.17
4.29
4.70
5.87
6.40
E2242SE2243SE2244S
2
3
4
16
16
16
19/.0117
19/.0117
19/.0117
0.008
0.008
0.008
0.20
0.20
0.20
0.015
0.015
0.015
0.38
0.38
0.38
0.179
0.190
0.209
4.55
4.83
5.31
16 AWG CONDUCTORS
E2262S*E2264S*
2
4
12
12
19/.0185
19/.0185
0.008
0.008
0.20
0.20
0.015
0.015
0.38
0.38
0.244
0.288
6.20
7.32
12 AWG CONDUCTORS
22 AWG CONDUCTORSE2100SE2102SE2103SE2104SE2106SE2108S
2
2
3
4
6
8
22
22
22
22
22
22
Solid
7/30
7/30
7/30
7/30
7/30
0.007
0.008
0.008
0.008
0.008
0.008
0.18
0.20
0.20
0.20
0.20
0.20
0.015
0.015
0.015
0.015
0.015
0.015
0.38
0.38
0.38
0.38
0.38
0.38
0.116
0.128
0.131
0.147
0.173
0.184
2.95
3.25
3.33
3.73
4.39
4.67
Color Code Chart
123456 7 8
NO. OF COND. COLOR
BlackRedWhiteGreenBrownBlueOrangeYellow
102
Sound, Alarm & Security Cable Electronics
Product Construction:Conductor:
• 22 thru 18 AWG fully annealed strandedbare copper per ASTM B-3
Insulation:• Premium-grade, coIor-coded PVC• Color Code: See charts below
Jacket:• Permaline® polyethylene, black• Temperature Range: –20°C to +60°C
Applications:• Rotor antenna controls• Outdoor installations• Direct burial• Suggested voltage rating: 200 volts
Features:• Permaline® jackets resist deterioration• Sunlight-resistant• Moisture- and salt-resistant
Product Construction:Conductor:
• 22 thru 16 AWG fully annealed strandedbare copper per ASTM B-3
Insulation:• Premium-grade, color-coded PVC• Color Code: See chart below
Jacket:• PVC, chrome gray, or black
(C4080, C4090)• Temperature Range: –20°C to +80°C
Applications:• Compatible with Alliance Ham/CB and
TV rotors• Suggested voltage rating: 200 volts
Packaging:• Please contact Customer Service for
packaging and color options
Antenna Rotor
CATALOGNUMBER
NO. OFCOND.
AWGSIZE
COND.STRAND.
NOM. INSULATIONTHICKNESS
NOM. JACKET THICKNESS NOMINAL O.D.
INCHES mm INCHES mm INCHES mm
C5076C5086C5096C5078C5460†C5084
4
5
8
4
2
4
22
22
22
20
18
18
7/30
7/30
7/30
10/30
16/30
16/30
0.010
0.010
0.010
0.010
0.016
0.016
0.25
0.25
0.25
0.25
0.25
0.40
0.020
0.020
0.020
0.020
0.020
0.030
0.51
0.51
0.51
0.51
0.51
0.76
0.165
0.175
0.205
0.180
0.210
0.245
4.19
4.45
5.21
4.57
5.33
6.22
Antenna Rotor CableColor Code Chart
12345678
NO. OF COND. COLOR
BlackWhiteRedGreenYellowBlueBrownOrange
†Color Code Black/Red
CATALOGNUMBER
NO. OFCOND.
AWGSIZE
COND.STRAND.
NOM. INSULATIONTHICKNESS
NOM. JACKET THICKNESS NOMINAL O.D.
INCHES mm INCHES mm INCHES mm
C1118C1124C1130C1119C1126C1123
4
5
8
4
5
4
22
22
22
20
20
18
7/30
7/30
7/30
10/30
10/30
16/30
0.010
0.010
0.010
0.010
0.010
0.016
0.25
0.25
0.25
0.25
0.25
0.40
0.020
0.020
0.020
0.020
0.020
0.030
0.51
0.51
0.51
0.51
0.51
0.76
0.160
0.175
0.205
0.180
0.195
0.255
4.06
4.45
5.21
4.57
4.95
6.48
16/18 ga.12
20/22 ga.123456
NO. OF COND. COLOR
BlackRed
WhiteGreenYellowBlueBrownOrange
C4080
C4090
8
8
6-222-18
6-202-16
7/3016/30
10/3026/30
0.0120.016
0.0120.016
0.300.41
0.300.41
0.030
0.030
0.76
0.76
0.260
0.280
6.60
7.11
COMBINATION ROTOR CABLE
Combination Rotor CableColor Code Chart
103
Electronics Sound, Alarm & Security Cable
Product Construction:Conductor:
• Solid bare copper per ASTM B-3
Insulation:• Semi-rigid, flame-retardant PVC• Color Code: See chart below
Core:• Conductors in a quad configuration
(C4412)
Jacket:• Low-temperature, flame-retardant beige
PVC (–20°C to +60°C)• Sequential footage markings to facilitate
installation• Cables are suitable for installation with
T-18 staples
Applications:• Wiring for single-line telephone service
(not recommended for multiple-line use)• Intercom systems and speaker extension
service• Suggested voltage rating: 300 volts
Compliances:• UL Listed Type CMR/CMX- Indoor/Outdoor• NEC Article 800 Type CMR
(UL: 60°C, 300V)• C4413 only, Category 3
Packaging:• Please contact Customer Service for
packaging and color options
Telephone Station/Intercom & Speaker/Burglar AlarmNEC Type CMR/CMX- Indoor/Outdoor
Color Code Chart
12
NO. OF COND. COLOR
RedGreen
34
NO. OF COND. COLOR
YellowBlack
CATALOGNUMBER
NO. OFCOND.
AWGSIZE
COND.STRAND.
NOM. INSULATIONTHICKNESS
NOM. JACKETTHICKNESS NOMINAL O.D.
INCHES mm INCHES mm INCHES mm
C4408C4408STC4410C4412C4412ST
2
2
3
4
4
22
22
22
22
22
Solid
7/.0096
Solid
Solid
7/.0096
0.007
0.007
0.007
0.007
0.007
0.18
0.18
0.18
0.18
0.18
0.018
0.020
0.016
0.015
0.015
0.46
0.51
0.41
0.38
0.38
0.115
0.125
0.118
0.125
0.135
2.92
3.18
3.00
3.18
3.43
Color Code Chart (Bandmarked)
1
NO. OF PAIR COLOR
White-Blue BandBlue
CATALOGNUMBER
NO. OFPAIRS
AWGSIZE
COND.STRAND.
NOM. INSULATIONTHICKNESS
NOM. JACKETTHICKNESS NOMINAL O.D.
INCHES mm INCHES mm INCHES mm
C4413 2 24 Solid 0.007 0.18 0.015 0.38 0.145
X
0.095
3.68
X
2.41
2
NO. OF PAIR COLOR
White-Orange Band Orange
TELEPHONE STATION CATEGORY 3
Product Construction:Conductor:
• 22 thru 18 AWG one tinned/one bare fullyannealed stranded copper
• Stranded bare copper per ASTM B-3 orstranded tinned copper per ASTM B-33
Insulation:• Premium-grade, color-coded PVC• Temperature Range: – 20°C to + 60°C• Color Code: See chart below
Applications:• Burglar alarms• Intercom systems• Remote control circuits• Suggested voltage rating: 150 volts
Features:• Polarity ridge for easy identification
Compliances:• NEC Article 725 Type CL2
(UL: 60°C, 150V)• Designed to Meet UL 70,000 BTU Vertical
Tray Flame Test
Packaging:• Please contact Customer Service for
packaging and color options
Note: Outdoor rating allows cable to be exposed for shortdistances from the network interface device on the outsideof the house to the point where the cable enters the house.This type of cable is not to be buried or direct buried.
CATALOGNUMBER
NO. OFCOND.
AWGSIZE
COND.STRAND.
NOM. INSULATION THICKNESS
INCHES
C6310C6311C6312C6313
2
2
2
3
22
20
18
18
7/30
7/28
16/30
7/0.015
mm
0.024
0.024
0.024
0.024
0.156
0.172
0.192
0.202
NOMINAL O.D.
NOM.* C-C CAP.pF/ftINCHES mm
20.0
22.5
24.5
28.5
0.61
0.61
0.61
0.61
3.96
4.37
4.88
5.13 *Capacitance between conductors
Color Code Chart
1. White-White2. Brown-Brown
STOCK COLORSORDERING
SUFFIX
02
08
3. Black-White
STOCK COLORSORDERING
SUFFIX
96
BURGLAR ALARM
INTERCOM AND SPEAKER
Product Construction:Conductor:• 18 AWG fully annealed solid bare copper
per ASTM B-3
Insulation:• Premium-grade, color-coded PVC• Premium grade PE jacket, black• Nylon rip cord to facilitate jacket removal• Temperature Range: -20ºC to +60ºC• Color Code: See chart below
Jacket Marking:• CAROL (SIZE) 30V SPRINKLER
SYSTEMS WIRE - DIRECT BURIALE54567 (UL)
Applications:• Low-voltage golf course satellite
sprinkler control• Residential sprinkler solenoid control
Industry Approvals:• UL Listed under a UL Miscellaneous
Wire file• UL Listed for outdoors applications• UL Listed for direct burial applications
Packaging:• See tabular data above• Please contact Customer Service for
packaging and color options
23824-60-0123804-18-0123815-60-0123825-60-0123805-18-0123817-60-0123827-60-0123807-18-0123810-18-01
4
4
5
5
5
7
7
7
10
18
18
18
18
18
18
18
18
18
Cuff
Spool
Cuff
Cuff
Spool
Cuff
Cuff
Spool
Reel
8.5 x 12.25 x 14
10.625 x 10.625 x 6.313
8.5 x 12.25 x 14
9.5 x 14 x 17
10.625 x 10.625 x 6.313
8.5 x 12.25 x 14
9.5 x 14 x 17
10.625 x 10.625 x 10.313
–
22
18
13
27
22
18
36
31
44
079407238248
079407908047
079407238156
079407238255
079407908054
079407238170
079407238279
079407908078
079407908108
CATALOGNUMBER
NO. OFCOND.
AWGSIZE
100
500
50
100
500
50
100
500
500
LENGTHOF CORD
(FEET)PACKAGE
TYPE
30
30
30
30
30
30
30
30
30
VOLTS
15
15
15
15
15
15
15
15
15
AMPS
POWER RATING(1)
UPC NUMBER
450
450
450
450
450
450
450
450
450
WATTS
6
1
6
6
1
6
6
1
1
PKGPERCTN.
APPROX.WEIGHT PERCTN (LBS)(S)
CARTONDIMENSIONS
(H x W x D)
(1) Amps and watts are offered ONLY as a guide to the end user(S) Actual shipping weight may vary.
LOW VOLTAGE SPRINKLER WIRE - 30 VOLTS - UL
Color Code Chart
12345678910
NO. OF CONDUCTORS COLOR
BlackWhiteRedGreenOrangeYellowBlueBrownGrayPurple
104
Sound, Alarm & Security Cable Electronics
Low-Voltage Sprinkler Wire60ºC 30 Volts UL
105
Electronics Sound, Alarm & Security Cable
Product Construction:Conductors:• 18 AWG annealed solid bare copper per
ASTM B-3
Insulation:• Premium-grade, color-coded PVC• Color Code: See chart below
Jacket:• Polyvinylchloride (PVC), brown• Temperature Range: -20ºC to +60ºC
Jacket Marking:• CAROL (SIZE) CSA LL# TYPE LVT FT-4
Applications:• Thermostat control• Heating and air conditioning installations• Touch-plate systems• Burglar alarms• Intercom systems• Door bells• Annunciator and bell systems• Remote control units• Signal systems• Other low-voltage installations
Industry Approvals:• CSA Type LVT
Packaging:• Please contact Customer Service for
packaging and color options
0509205093*050940509505096*05097*05098*05099*05091*
2
3
4
5
6
7
8
9
10
18
18
18
18
18
18
18
18
18
Solid
Solid
Solid
Solid
Solid
Solid
Solid
Solid
Solid
0.016
0.016
0.016
0.016
0.016
0.016
0.016
0.016
0.016
0.41
0.41
0.41
0.41
0.41
0.41
0.41
0.41
0.41
0.210
0.220
0.242
0.262
0.280
0.285
0.304
0.328
0.360
5.33
5.59
6.15
6.65
7.11
7.24
7.75
8.33
9.14
25
33
41
50
60
65
74
83
92
2000'
500'
1000'
1000'
1000'
1000'
1000'
1000'
250'
CATALOGNUMBER
NO. OFCOND.
AWGSIZE
COND.STRAND
NOM. INS.THICKNESS
INCHES mm INCHES mm
NOMINAL. O.D. APPROX. NET WEIGHT
LBS/M'(S)STD.CTN.
23456789
10
NO. OF CONDUCTORS COLOR
White, Red
White, Red, Green
White, Red, Green, Blue
White, Red, Green, Blue, Yellow
White, Red, Green, Blue, Yellow, Brown
White, Red, Green, Blue, Yellow, Brown, Orange
White, Red, Green, Blue, Yellow, Brown, Orange, Black
White, Red, Green, Blue, Yellow, Brown, Orange, Black, Purple
White, Red, Green, Blue, Yellow, Brown, Orange, Black, Purple, Gray
6.0
5.5
5.0
4.5
4.0
3.5
3.0
2.5
2.0
1.5
1.0
.5
00 50 100 150 200 250 300 350 400 450 500
NE
C R
EC
OM
ME
ND
ED
MA
X V
OLT
DR
OP
3%
MA
X
VOLTAGE DROP PER (1) AMPBASED ON 115 VOLTS
VO
LTA
GE
DR
OP
/AM
P
LENGTH OF RUN (FEET)
APPROXIMATE VOLTAGE DROP/AMP AT 68ºF
26 A
WG
24 A
WG
23 A
WG
22 A
WG
21 A
WG
20 A
WG
18 AWG
16 AWG
Color Code Chart
* Non-stock item; minimum quantity purchase required.(S) Actual shipping weight may vary.
18 AWG THERMOSTAT WIRE – 300 VOLT – CSA TYPE LVT
Thermostat Wire60ºC 300 Volt CSA Type LVT
23456789
10
NO. OF CONDUCTORS COLOR
White, Red
White, Red, Green
White, Red, Green, Blue
White, Red, Green, Blue, Yellow
White, Red, Green, Blue, Yellow, Brown
White, Red, Green, Blue, Yellow, Brown, Orange
White, Red, Green, Blue, Yellow, Brown, Orange, Black
White, Red, Green, Blue, Yellow, Brown, Orange, Black, Purple
White, Red, Green, Blue, Yellow, Brown, Orange, Black, Purple, Gray
6.0
5.5
5.0
4.5
4.0
3.5
3.0
2.5
2.0
1.5
1.0
.5
00 50 100 150 200 250 300 350 400 450 500
NE
C R
EC
OM
ME
ND
ED
MA
X V
OLT
DR
OP
3%
MA
X
VOLTAGE DROP PER (1) AMPBASED ON 115 VOLTS
VO
LTA
GE
DR
OP
/AM
P
LENGTH OF RUN (FEET)
APPROXIMATE VOLTAGE DROP/AMP AT 68ºF
26 A
WG
24 A
WG
23 A
WG
22 A
WG
21 A
WG
20 A
WG
18 AWG
16 AWG
Color Code Chart
Product Construction:Conductors:• 20 and 18 AWG annealed solid bare
copper per ASTM B-3
Insulation:• Premium-grade, coIor-coded PVC• Color Code: See chart below
Jacket:• Polyvinylchloride (PVC), white• Temperature Range: -20ºC to +105ºC
Jacket Marking:• CAROL AWG TYPE CL2 E# (UL) 105ºC
SUNLIGHT RESISTANT - MADE IN USA
Applications:• Thermostat control• Heating and air conditioning installations• Touch-plate systems• Burglar alarms• Intercom systems• Door bells• Annunciator and bell systems• Remote control units• Signal systems• Other low-voltage installations
Industry Approvals:• UL Listed Type CL2
Packaging:• Please contact Customer Service for
packaging and color options
054820548305484054850548605487054880548905481
2
3
4
5
6
7
8
9
10
20
20
20
20
20
20
20
20
20
Solid
Solid
Solid
Solid
Solid
Solid
Solid
Solid
Solid
0.008
0.008
0.008
0.008
0.008
0.008
0.008
0.008
0.008
0.203
0.203
0.203
0.203
0.203
0.203
0.203
0.203
0.203
0.128
0.135
0.144
0.168
0.175
0.175
0.186
0.210
0.235
3.25
3.43
3.66
4.27
4.45
4.45
4.72
5.33
5.97
11
16
19
24
27
31
35
40
45
1000'
1000'
500'
500'
500'
500'
500'
500'
250'
CATALOGNUMBER
NO. OFCOND.
AWGSIZE
COND.STRAND
NOM. INS.THICKNESS
INCHES mm INCHES mm
NOMINAL. O.D. APPROX. NET WEIGHT
LBS/M'(S)STD.CTN.
20 AWG THERMOSTAT WIRE – 300 VOLT – UL TYPE CL2
CATALOGNUMBER
NO. OFCOND.
AWGSIZE
COND.STRAND
NOM. INS.THICKNESS
INCHES mm INCHES mm
NOMINAL. O.D. APPROX. NET WEIGHT
LBS/M'(S)STD.CTN.
18 AWG THERMOSTAT WIRE – 300 VOLT – UL TYPE CL2
055820558305584055850558605587055880558905581
2
3
4
5
6
7
8
9
10
18
18
18
18
18
18
18
18
18
Solid
Solid
Solid
Solid
Solid
Solid
Solid
Solid
Solid
0.008
0.008
0.008
0.008
0.008
0.008
0.008
0.008
0.008
0.203
0.203
0.203
0.203
0.203
0.203
0.203
0.203
0.203
0.145
0.154
0.170
0.193
0.200
0.210
0.230
0.245
0.300
3.68
3.91
4.32
4.90
5.08
5.33
5.84
6.22
7.62
16
22
28
36
42
48
54
61
69
1000'
1000'
500'
500'
500'
500'
500'
500'
250'
(S) Actual shipping weight may vary.
106
Sound, Alarm & Security Cable Electronics
Thermostat Wire105ºC 300 Volt UL Type CL2
107
Electronics Sound, Alarm & Security Cable
Thermostat Wire, Unjacketed60ºC Low Voltage and Intercom Cable
057820578305784*05785*05786*05788*
2
3
4
5
6
8
20
20
20
20
20
20
Solid
Solid
Solid
Solid
Solid
Solid
0.008
0.008
0.008
0.008
0.008
0.008
0.203
0.203
0.203
0.203
0.203
0.203
0.098
0.106
0.119
0.133
0.147
0.162
2.49
2.69
3.01
3.38
3.73
4.11
7.5
11.0
15.0
18.5
22.0
30.0
4000'
2000'
2000'
1000'
1000'
1000'
CATALOGNUMBER
NO. OFCOND.
AWGSIZE
COND.STRAND
NOM. INS.THICKNESS
INCHES mm INCHES mm
NOMINAL. O.D. APPROX. NET WEIGHT
LBS/M'(S)STD.CTN.
20 AWG – TWISTED CONDUCTORS – NO JACKET
* Non-stock item; minimum quantity purchase required.(S) Actual shipping weight may vary.
Product Construction:Conductors:• 20 AWG annealed solid bare copper per
ASTM B-3
Insulation:• Premium-grade, coIor-coded PVC• Temperature Range: -20ºC to +60ºC• Color Code: See chart below
Jacket:• This product is unjacketed
Applications:• Thermostat control• Heating and air conditioning installations• Touch-plate systems• Burglar alarms• Intercom systems• Door bells• Annunciator and bell systems• Remote control units• Signal systems• Other low-voltage installations
Packaging:• Please contact Customer Service for
packaging and color options
234568
NO. OF CONDUCTORS COLOR
White, Red
White, Red, Green
White, Red, Green, Blue
White, Red, Green, Blue, Yellow
White, Red, Green, Blue, Yellow, Brown
White, Red, Green, Blue, Yellow, Brown, Orange, Black
Color Code Chart
108
Electronics
Plenum Cable 8
Index Page
Multi-Conductor, Unshielded 109-110
Multi-Conductor, Foil Shield 111-112
Multi-Paired,Foil Shield 113-114
Multi-PairedFoil Shield, Mid-Cap 115
Multi-Paired,Foil Shield, Lo-Cap® 116
Multi-Paired, IndividuallyFoil Shielded 117
NEC Article 725, Article 800,Coaxial Cable, Plenum 118
Most industrial and officebuildings today feature dropceilings which support varioustypes of lighting, airducts forheating and cooling systems,and wiring for power andcommunications.
This space in a buildingbetween the floor above andthe drop ceiling is beingutilized for ventilation systemsor used for return airdistribution and is referred toas a “PLENUM.”
Because the plenum iscontinuous across each floor of a building, it can create asignificant hazard by spreadingflames quickly fromcombustible materials such aswire insulation.
The National Electrical Code (NEC) demands thatwiring in the plenum either beinstalled inside metal conduitor have jacket materials thatprovide adequate fireresistance and low smoke-producing characteristics astested and approved by arecognized agency such asUnderwriters Laboratory (UL).
General Cable’s large mix of Carol® Brand plenum cable and wire products featuresDuPont Teflon®, otherfluorocarbon resins as well as Flexguard.® Flexguard® is a unique copolymer blendwhich joins superiorperformance with superiorhandling characteristics. They meet all UL and NECrequirements for low-smokecharacteristics and flame-retardant qualities.
Also, General Cable’splenum products provideoutstanding electricalproperties, high-temperatureperformance and excellentchemical resistance.
General Cable’s Carol® Brandplenum cable is available tomeet the requirements of NECArticles 725 and 800.
C3110C3114 C3111 C3117 C3118C3119C3112C3120C3113C3125C3121C3122 C3123 C3124
109
Electronics Plenum Cable
C3129†
C3128†
C3127
C3115C3116
CATALOGNUMBER
NO. OFCOND.
AWGSIZE
COND.STRAND.
NOM. INSULATIONTHICKNESS
2
4
22
22
7/30 TC
7/30 TC
0.008
0.008
0.20
0.20
0.015
0.015
0.38
0.38
0.122
0.141
3.10
3.58
NOM.*C-C CAP. pF/ft
30.0
30.0
Product Construction:Conductor:
• 22 thru 12 AWG fully annealed strandedtinned or bare copper per ASTM B3, B8 or B33
Insulation:• Premium-grade, coIor-coded Flexguard®
PVC• Color Code: See chart below
Jacket:• Flexguard® PVC, Natural• Temperature Range: 0°C to + 75°C• Sequential footage marked to facilitate
installation• Ripcord available—consult Customer
Service for details
Applications:• Intercom systems• Background music• Audio systems• Power-limited control circuits• Suggested voltage rating: 150 volts
Compliances:• NEC Article 725 (UL: 75°C, 150V)• NEC Article 800 (UL: 75°C, 300V)• Designed to Meet NFPA 262 Flame Test
Features:• Flexible• Easy to terminate
Packaging:• Please contact Customer Service for
packaging and color options
Multi-Conductor, UnshieldedNEC Type CMP (UL) c(UL) and/or CL3P
22 AWG CONDUCTORS
2
3
4
5
6
8
2
3
4
5
6
8
10
12
18
18
18
18
18
18
18
18
18
18
18
18
18
18
Solid BC
Solid BC
Solid BC
Solid BC
Solid BC
Solid BC
7/26 BC
7/26 BC
7/26 BC
7/26
7/26 BC
7/26 BC
7/26
7/26
0.008
0.008
0.008
0.008
0.008
0.008
0.008
0.008
0.008
0.008
0.008
0.008
0.008
0.008
0.20
0.20
0.20
0.20
0.20
0.20
0.20
0.20
0.20
0.20
0.20
0.20
0.20
0.20
0.015
0.015
0.015
0.015
0.015
0.015
0.015
0.015
0.015
0.015
0.015
0.015
0.015
0.015
0.38
0.38
0.38
0.38
0.38
0.38
0.38
0.38
0.38
0.38
0.38
0.38
0.38
0.38
0.142
0.151
0.166
0.182
0.199
0.216
0.156
0.166
0.182
0.200
0.216
0.239
0.278
0.287
3.61
3.84
4.22
4.62
5.05
5.49
3.96
4.22
4.62
5.08
5.49
6.07
7.06
7.29
37.0
37.0
37.0
37.0
37.0
37.0
35.0
35.0
35.0
54.6
35.0
35.0
35.0
35.0
18 AWG CONDUCTORS
2 16 0.008 40.0
16 AWG CONDUCTORS
2 14 19/.0147 BC 0.010 40.0
14 AWG CONDUCTORS
2 12 19/.0185 BC 0.010
0.20
0.20
0.20
0.015
0.015
0.015
0.38
0.38
0.38
0.178
0.212
0.254
4.52
5.38
6.45 43.0
12 AWG CONDUCTORS
*Capacitance between conductors†CL3P only
Color Code Chart NO. OF COND. COLOR
BlackWhiteRedGreenBrownBlueOrangeYellow
12345678
19/.0117 BC
INCHES mm
NOM. JACKETTHICKNESS
INCHES mm
NOMINAL O.D.
INCHES mm
110
Plenum Cable Electronics
C3126†
C3193C3194C3195
C3102C3190C3103C3134C3192C3191C3178C3179
Product Construction:Conductor:
• 22 thru 14 AWG fully annealed strandedtinned or bare copper per ASTM B3, B8 or B33
Insulation:• Premium-grade, coIor-coded Flexguard®
PVC• Color Code: See chart below
Jacket:• Fluoropolymer, Natural• Temperature Range: –20°C to +75°C• Sequential footage marked to facilitate
installation• Ripcord available—consult Customer
Service for details
Applications:• Intercom systems• Background music• Audio systems• Power-limited control circuits• Suggested voltage rating: 150 volts
Compliances:• NEC Article 725 (UL: 75°C, 150V)• NEC Article 800 (UL: 75°C, 300V)• Designed to Meet NFPA 262 Flame Test
Features:• Abrasion-, chemical- and water-resistant
jacket
Packaging:• Please contact Customer Service for
packaging and color options
Multi-Conductor, UnshieldedNEC Type CMP (UL) c(UL) and/or CL2P
22 AWG CONDUCTORS
CATALOGNUMBER
NO. OFCOND.
AWGSIZE
COND. STRAND.
NOM. INSULATIONTHICKNESS
INCHES mm
NOM. JACKETTHICKNESS
INCHES mm
NOMINAL O.D.
NOM. C-C
CAP.*pF/ftINCHES mm
2
4
22
22
7/30 TC
7/30 TC
0.006
0.006
0.15
0.15
0.010
0.010
0.25
0.25
0.089
0.121
2.26
3.07
29.0
29.0
C3105†C3106†
18 AWG CONDUCTORS2
3
4
5
6
8
10
12
18
18
18
18
18
18
18
18
7/26 BC
7/26 BC
7/26 BC
7/26
7/26 BC
7/26 BC
7/26 BC
7/26 BC
0.008
0.008
0.008
0.008
0.008
0.008
0.008
0.008
0.20
0.20
0.20
0.20
0.20
0.20
0.20
0.20
0.010
0.010
0.010
0.010
0.010
0.010
0.010
0.010
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.123
0.143
0.163
0.187
0.198
0.223
0.244
0.263
3.12
3.63
4.14
4.75
5.03
5.66
6.19
6.68
31.0
31.0
31.0
30.8
31.0
31.0
31.0
31.0
16 AWG CONDUCTORS2
3
4
16
16
16
19/.0117 BC
7/.0192 BC
7/.0192 BC
0.008
0.008
0.008
0.20
0.20
0.20
0.010
0.010
0.010
0.25
0.25
0.25
0.141
0.164
0.187
3.58
4.17
4.75
33.0
33.0
33.0
2 14 19/.0147 BC 0.010 0.25 0.010 0.25 0.168 4.27 35.0
14 AWG CONDUCTORS
Color Code Chart
123456789
101112
NO. OF COND. COLOR
BlackWhiteRedGreenBrownBlueOrangeYellowVioletGrayPinkTan
C3135 2 12 19/.0185 0.010 0.25 0.010 0.25 0.238 6.05 37.0
12 AWG CONDUCTORS
*Capacitance between conductors†CL2P only
111
Electronics Plenum Cable
Product Construction:Conductor:
• 22 thru 16 AWG fully annealed strandedtinned or bare copper per ASTM B3, B8 or B33
Insulation:• Premium-grade, coIor-coded Flexguard®
PVC• Color Code: See chart below
Shield:• 100% Flexfoil® aluminum/polyester foil
with 25% overlap, minimum• Stranded tinned copper drain wire
Jacket:• Flexguard® PVC, natural• Temperature Range: 0°C to + 75°C• Sequential footage marked to facilitate
installation• Ripcord available—consult Customer
Service for details
Applications:• Intercom systems• Background music• Audio systems• Power-limited control circuits• Suggested voltage rating: 150 volts
Compliances:• NEC Article 725 (UL: 75°C, 150V)• NEC Article 800 (UL: 75°C, 300V)• Designed to Meet NFPA 262 Flame Test
Features:• Flexible• Easy to terminate
Packaging:• Please contact Customer Service for
packaging and color options
Multi-Conductor, Foil ShieldNEC Type CMP (UL) c(UL) and CL3P
Color Code Chart
123456789101112
NO. OF COND. COLOR
BlackWhiteRedGreenBrownBlueOrangeYellowVioletGrayPinkTan
CATALOGNUMBER
NO. OFCOND.
AWGSIZE
COND. STRAND.
NOM. INSULATIONTHICKNESS
INCHES mm
NOM. JACKETTHICKNESS
INCHES mm
NOMINALO.D.
NOMINAL CAP.*pF/ft
A BINCHES mm
C3158C3159
2
4
22
22
7/30 TC
7/30 TC
0.008
0.008
0.20
0.20
0.38
0.38
0.127
0.146
91.0
81.0
51.0
45.0
3.23
3.71
0.015
0.015
22 AWG CONDUCTORS
C3060C3061C3062C3064C3063C3065C3183C3184
2
4
2
3
4
6
10
12
18
18
18
18
18
18
18
18
Solid BC
Solid BC
7/26 BC
7/26 BC
7/26 BC
7/26 BC
7/26
7/26
0.008
0.008
0.008
0.008
0.008
0.010
0.012
0.007
0.20
0.20
0.20
0.20
0.20
0.25
0.30
0.18
0.38
0.38
0.38
0.38
0.38
0.38
0.38
0.38
0.148
0.171
0.164
0.169
0.186
0.232
0.310
0.280
120.0
104.0
110.0
96.0
96.0
86.0
84.0
94.6
67.0
58.0
61.0
53.0
53.0
48.0
47.0
52.5
3.76
4.34
4.17
4.29
4.72
5.89
7.87
7.11
0.015
0.015
0.015
0.015
0.015
0.015
0.015
0.015
18 AWG CONDUCTORS
C3068 2 16 0.008 0.20 0.38 0.187 134.075.04.750.015
16 AWG CONDUCTORS19/.0117 BC
*A-Capacitance between conductors*B-Capacitance between one conductor and other conductors connected to shield
112
Plenum Cable Electronics
Product Construction:Conductor:
• 22 thru 16 AWG fully annealed strandedtinned or bare copper per ASTM B3, B8 orB33
• Class B stranding per ASTM B-8
Insulation:• Premium-grade, coIor-coded Flexguard®
• Color Code: See chart below
Shield:• 100% Flexfoil® aluminum/polyester foil,
with 25% overlap• Stranded tinned copper drain wire
Jacket:• Fluoropolymer, natural• Temperature Range: –20°C to +75°C• Sequential footage marked to facilitate
installations• Stranded tinned copper drain wire• Ripcord available—consult Customer
Service for details
Applications:• Intercom systems• Background music• Audio dystems• Power-limited control circuits• Suggested voltage rating: 150 volts
Compliances:• NEC Article 725 (UL: 75°C, 150V)• NEC Article 800 (UL: 75°C, 300V)• Designed to Meet NFPA 262 Flame Test
Features:• Abrasion-, chemical- and water-resistant
jacket
Packaging:• Please contact Customer Service for
packaging and color options
Color Code Chart
123456789
101112
NO. OF COND. COLOR
BlackWhiteRedGreenBrownBlueOrangeYellowVioletGrayPinkTan
*CL2P only**A -Capacitance between conductors**B -Capacitance between one conductor and other conductors connected to shield
C3154*C3310*C3155*C3311*
22
22
22
22
7/30 TC
7/30 TC
7/30 TC
7/30 TC
0.006
0.006
0.006
0.006
0.15
0.15
0.15
0.15
0.25
0.25
0.25
0.25
0.103
0.116
0.130
0.152
92.0
81.0
81.0
73.0
51.0
45.0
45.0
40.0
2.62
2.95
3.30
3.86
0.010
0.010
0.010
0.010
22 AWG CONDUCTORS
C3320*C3321*C3322*
20
20
20
7/28 TC
7/28 TC
7/28 TC
0.007
0.007
0.007
0.18
0.18
0.18
0.25
0.25
0.25
0.120
0.136
0.153
96.0
84.0
84.0
53.0
46.0
46.0
3.05
3.45
3.89
0.010
0.010
0.010
20 AWG CONDUCTORS
C3162C3164C3163C3166C3180C3181C3182
18
18
18
18
18
18
18
7/26 BC
7/26 BC
7/26 BC
7/26 BC
7/26 BC
7/26 BC
7/26 BC
0.008
0.008
0.008
0.008
0.008
0.008
0.008
0.20
0.20
0.20
0.20
0.20
0.20
0.20
0.25
0.25
0.25
0.25
0.25
0.25
0.30
0.152
0.158
0.178
0.212
0.229
0.273
0.285
98.0
85.0
85.0
76.0
76.0
76.0
76.0
54.0
47.0
47.0
43.0
43.0
43.0
43.0
3.86
4.01
4.52
5.38
5.82
6.93
7.24
0.010
0.010
0.010
0.010
0.010
0.010
0.012
18 AWG CONDUCTORS
16 AWG CONDUCTORS
Multi-Conductor, Foil ShieldNEC Type CMP (UL) c(UL) and/or CL2P
CATALOGNUMBER
NO. OFCOND.
AWGSIZE
COND. STRAND.
NOM. INSULATIONTHICKNESS
INCHES mm
NOM. JACKETTHICKNESS
INCHES mm
NOMINALO.D.
NOMINAL CAP.**pF/ft
A BINCHES mm
2
3
4
6
2
3
4
2
3
4
6
8
10
12
C3169C3340C3341
2
3
4
16
16
16
19/.0117 BC
7/.0192 BC
7/.0192 BC
0.008
0.008
0.008
0.20
0.20
0.20
0.25
0.25
0.25
0.181
0.185
0.203
112.0
93.0
93.0
62.0
52.0
52.0
4.60
4.70
5.16
0.010
0.010
0.010
113
Electronics Plenum Cable
Product Construction:Conductor:
• 22 and 24 AWG fully annealed strandedtinned copper per ASTM B33
Insulation:• Premium-grade, coIor-coded fluoropolymer• Color Code: See chart below
Shield:• 100% Flexfoil® aluminum/polyester foil
with 25% overlap, minimum• Stranded tinned copper drain wire
Jacket:• Fluoropolymer, natural• Temperature Range: –40°C to + 150°C• Sequential footage marked to facilitate
installation• Ripcord available—consult Customer
Service for details
Applications:• EIA RS-232 circuits• Remote control circuits• Process control and instrumentation• Power-limited control circuits• Suggested voltage rating: 300 volts
Compliances:• NEC Article 800 (UL: 150°C, 300V)• Designed to Meet NFPA 262 Flame Test
Features:• Abrasion-, chemical- and water-resistant
jacket
Packaging:• Please contact Customer Service for
packaging and color options
Multi-Paired, Foil ShieldNEC Type CMP (UL) c(UL)
CATALOGNUMBER
NO. OFPAIRS
AWGSIZE
COND.STRAND.
NOM. INSULATIONTHICKNESS
INCHES mm
NOM. JACKETTHICKNESS
INCHES mm
NOMINALO.D.
NOMINAL CAP.*pF/ft
A BINCHES mm
C3204C3205C3206C3207C3208
1
2
3
4
6
22
22
22
2222
7/30 TC
7/30 TC
7/30 TC
7/30 TC
7/30 TC
0.006
0.006
0.006
0.006
0.006
0.15
0.15
0.15
0.15
0.15
0.25
0.25
0.25
0.25
0.25
0.117
0.151
0.177
0.200
0.237
55.8
45.0
36.0
45.0
32.4
31.0
25.0
20.0
25.0
18.0
2.97
3.84
4.50
5.08
6.02
0.010
0.010
0.010
0.010
0.010
22 AWG CONDUCTORS
C3150C3153C3151C3165C3152
2
3
4
6
12.5
24
24
24
24
24
7/32 TC
7/32 TC
7/32 TC
7/32 TC
7/32 TC
0.006
0.006
0.006
0.006
0.006
0.15
0.15
0.15
0.15
0.15
0.25
0.25
0.25
0.25
0.30
0.130
0.152
0.170
0.200
0.277
39.6
32.4
30.6
30.6
30.6
22.0
18.0
17.0
17.0
17.0
3.30
3.86
4.32
5.08
7.04
0.010
0.010
0.010
0.010
0.012
24 AWG CONDUCTORS
*A -Capacitance between conductors*B-Capacitance between one conductor and other conductors connected to shield
Color Code Chart
123456789
1011121C
NO. OFPAIRS COLOR
Black & YellowRed & VioletDark Blue & BrownOrange & Dark GreenPink & GrayTan & WhiteLight Blue & Light GreenRed/White & White/RedOrange/White & White/OrangeYellow/White & White/YellowGray/White & White/GrayBlue/White & White/BlueDark Green/Yellow
114
Plenum Cable Electronics
Product Construction:Conductor:
• 22 and 18 AWG fully annealed strandedtinned copper per ASTM B33 or strandedbare copper per ASTM B3
Insulation:• Premium-grade, coIor-coded Flexguard®
PVC• Color Code: See chart below
Shield:• 100% Flexfoil® aluminum/polyester foil
with 25% overlap, minimum• Stranded tinned copper drain wire
Jacket:• Fluoropolymer, Natural• Temperature Range: –20°C to +75°C• Sequential footage marked to facilitate
installation• Ripcord available—consult Customer
Service for details
Applications:• EIA RS-232 circuits• Remote control circuits• Process control and instrumentation• Power-limited control circuits• Suggested voltage rating: 150 volts
Compliances:• NEC Article 800 (UL: 75°C, 300V)• NEC Article 725 (UL: 75°C, 150V)• Designed to Meet NFPA 262 Flame Test
Features:• Abrasion-, chemical- and water-resistant
jacket
Packaging:• Please contact Customer Service for
packaging and color options
Multi-Paired, Foil ShieldNEC Type CMP (UL) c(UL) and/or CL2P
CATALOGNUMBER
NO. OFPAIRS
AWGSIZE
COND.STRAND.
NOM. INSULATIONTHICKNESS
INCHES mm
NOM. JACKETTHICKNESS
INCHES mm
NOMINALO.D.
NOMINAL CAP.*pF/ft
A BINCHES mm
C3362C3364
2
4
18
18
7/26 BC
7/26 BC
0.008
0.008
0.020
0.020
0.25
0.25
0.205
0.277
79.0
59.0
44.0
33.0
5.21
7.04
0.010
0.010
18 AWG, CL2P/CMP, C(UL) 150 VOLTS
*A -Capacitance between conductors*B-Capacitance between one conductor and other conductors connected to shield
Color Code Chart
C3352C3353C3354C3356
2
3
4
6
22
22
22
22
7/30 TC
7/30 TC
7/30 TC
7/30 TC
0.007
0.007
0.007
0.007
0.180
0.180
0.180
0.180
0.25
0.25
0.25
0.25
0.157
0.194
0.207
0.246
66.0
53.0
53.0
48.0
37.0
30.0
30.0
27.0
3.99
4.42
4.75
5.74
0.010
0.010
0.010
0.010
22 AWG, CL2P, C(UL) 150 VOLTS
123456
NO. OFPAIRS COLOR
Black & YellowRed & VioletDark Blue & BrownOrange & Dark GreenPink & GrayTan & White
115
Electronics Plenum Cable
Product Construction:Conductor:
• 24 AWG fully annealed stranded tinnedcopper per ASTM B33
Insulation:• Premium-grade, coIor-coded fluoropolymer• Color Code: See chart below
Shield:• 100% Flexfoil® aluminum/polyester foil
with 25% overlap, minimum• Stranded tinned copper drain wire
Jacket:• Fluoropolymer, Natural• Temperature Range: –40°C to + 150°C• Sequential footage marked to facilitate
installation• Ripcord available—consult Customer
Service for details
Applications:• EIA RS-232 and RS-422 circuits• Remote control circuits• Process control and instrumentation• Power-limited control circuits• Suggested voltage rating: 300 volts
Compliances:• NEC Article 800 (UL: 150°C, 300V)• Designed to Meet NFPA 262 Flame Test
Features:• Abrasion-, chemical- and water-resistant
jacket
Packaging:• Please contact Customer Service for
packaging and color options
Multi-Paired, Foil Shield, Mid-CapNEC Type CMP (UL) c(UL)
CATALOGNUMBER
NO. OFPAIRS
AWGSIZE
COND.STRAND.
NOM. INSULATIONTHICKNESS
INCHES mm
NOM. JACKETTHICKNESS
INCHES mm
NOMINALO.D.
NOMINAL CAP.*pF/ft
A BINCHES mm
C3214C3215C3216C3217C3218
2
3
4
4.5
6
24
24
24
24
24
7/32 TC
7/32 TC
7/32 TC
7/32 TC
7/32 TC
0.010
0.010
0.010
0.010
0.010
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.150
0.177
0.201
0.214
0.239
30.0
27.0
27.0
27.0
25.0
17.0
15.0
15.0
15.0
14.0
3.81
4.50
5.11
5.18
6.07
0.010
0.010
0.010
0.010
0.010
24 AWG CONDUCTORS
*A -Capacitance between conductors*B-Capacitance between one conductor and other conductors connected to shield
Color Code Chart
123456
1C
NO. OFPAIRS COLOR
Black paired with YellowRed paired with VioletDark Blue paired with BrownOrange paired with Dark GreenPink paired with GrayTan paired with WhiteGreen with Yellow Stripe
116
Plenum Cable Electronics
Product Construction:Conductor:
• 24 AWG fully annealed stranded tinnedcopper per ASTM B33
Insulation:• Premium-grade, coIor-coded fluoropolymer• Color Code: See chart below
Shield:• 100% Flexfoil® aluminum/polyester foil
with 25% overlap, minimum• Stranded tinned copper drain wire
Jacket:• Fluoropolymer, natural• Temperature Range: –40°C to +150°C• Sequential footage marked to facilitate
installation• Ripcord available—consult Customer
Service for details
Applications:• EIA RS-232 and RS-422 circuits• Remote control circuits• Process control and instrumentation• Low capacitance requirements• Suggested voltage rating: 300 volts
Compliances:• NEC Article 800 (UL: 150°C, 300V)• Designed to Meet NFPA 262 Flame Test
Features:• Abrasion-, chemical- and water-resistant
jacket
Packaging:• Please contact Customer Service for
packaging and color options
Multi-Paired, Foil Shield, Lo-Cap®
NEC Type CMP (UL) c(UL)
Color Code Chart
123456
NO. OFPAIRS COLOR
Black paired with YellowRed paired with VioletDark Blue paired with BrownOrange paired with Dark GreenPink paired with GrayTan paired with White
CATALOGNUMBER
NO. OFPAIRS
AWGSIZE
COND.STRAND.
NOM. JACKETTHICKNESS
INCHES
C3028C3029C3030C3031
2
3
4
6
24
24
24
24
7/32 TC
7/32 TC
7/32 TC
7/32 TC
mm
0.010
0.010
0.010
0.012
0.25
0.25
0.25
0.30
NOMINAL O.D.
INCHES mm
0.159
0.183
0.246
0.285
4.04
4.65
6.25
7.24
NOMINAL CAP.*pF/ft IMPED.
ΩNOMA B
15.0
14.0
14.0
13.0
27.00
25.00
25.00
23.00
94.0
107.0
107.0
115.0 *A -Capacitance between conductors*B-Capacitance between one conductor and other conductors connected to shield
117
Electronics Plenum Cable
Product Construction:Conductor:
• 22 AWG fully annealed stranded tinnedcopper per ASTM B33
Insulation:• Premium-grade, coIor-coded fluoropolymer• Color Code: see chart below
Shield:• 100% Flexfoil® aluminum/polyester foil,
each with 25% overlap, minimum• Stranded tinned copper drain wire
Jacket:• Fluoropolymer, red• Temperature Range: –20°C to + 150°C• Sequential footage marked to facilitate
installation• Ripcord available—consult Customer
Service for details
Applications:• Point of sale systems• Remote control circuits• Process control and instrumentation• Power-limited control circuits• Suggested voltage rating: 300 volts
Compliances:• NEC Article 800 (UL: 150°C, 300V)• Designed to Meet NFPA 262 Flame Test
Features:• Individually shielded pairs for excellent
signal isolation• Abrasion-, chemical- and water-resistant
jacket
Packaging:• Please contact Customer Service for
packaging and color options
Multi-Paired, Individually Foil ShieldedNEC Type CMP (UL) c(UL)
C3156*C3157
2
3
22
22
7/30 TC
7/30 TC
0.006
0.006
0.15
0.15
0.25
0.25
0.147
0.184
63.0
63.0
35.0
35.0
3.73
4.67
0.010
0.010*Cabled on common axis to reduce diameter, foil out, common drain wire
**A -Capacitance between conductors**B -Capacitance between one conductor and other conductors connected to shield
Color Code Chart
12
C3156PAIR # COLOR
Black paired with RedWhite paired with Green
123
C3157PAIR # COLOR
Black paired with RedBlack paired with WhiteBlack paired with Green
CATALOGNUMBER
NO. OFPAIRS
AWGSIZE
COND.STRAND.
NOM. INSULATIONTHICKNESS
INCHES mm
NOM. JACKETTHICKNESS
INCHES mm
NOMINALO.D.
NOMINAL CAP.**pF/ft
A BINCHES mm
118
Plenum Cable Electronics
Flexguard® PVCNatural
Flexguard® PVCNatural
Flexguard® PVCNatural
Flexguard® PVCNatural
PVDF
PVDF
Flexguard® PVCNatural
Flexguard® PVCNatural
Flexguard® PVCNatural
Flexguard® PVCNatural
Flexguard® PVCNatural
Flexguard® PVCNatural
0.226
0.233
0.226
0.264
0.351
0.372
0.161
0.165
0.202
0.235
0.201
0.201
5.74
5.92
5.74
6.71
8.92
9.45
4.09
4.19
5.13
5.97
5.11
5.11
Product Construction:Conductor:
• 18 and 19 AWG fully annealed, solid barecopper per ASTM B-3; 20 AWG fullyannealed, stranded, tinned copper perASTM B-33
• 14, 18, 20 and 22 AWG solid copper-cladsteel per ASTM B-869
Insulation:• Premium-grade, cellular Fluoropolymer
Shield:• Bare or tinned copper or aluminum braid
with or without a polyester supportedaluminum foil shield
NEC Article 725, Article 800, Coaxial Cable, PlenumUL Type CL2P, UL & C(UL) type CMP
Jacket:• Flexguard® PVC, Natural• Temperature Range: 0°C to +60°C
Applications:• RF signal transmission• Video Display Terminals (VDT)• CCTV and MATV• Local Area Networks (LANs)• Programmable Logic Controllers (PLCs)• Suggested voltage rating: 150 volts
Compliances:• NEC Article 725 (UL: 60°C, 150V)• NEC Article 800 (UL: 60°C, 300V)• Designed to Meet NFPA 262 Flame Test
Packaging:• Please contact Customer Service for
packaging and color options
C3523RG 6/U TypePlenumC3521RG 6/U TypePlenumC3524RG 6/U TypePlenumC3525RG 6/U TypeQuad-ShieldPlenumC3528RG 11/U TypePlenum
C3529RG 11/U TypeQuad-ShieldPlenum
C3519RG 58/U TypePlenum
C3579RG 58/U TypeThinnetPlenum
C3526RG 59/U TypePlenumC3527RG 59/U TypeQuad-ShieldPlenumC3500RG 59/U TypePlenum
C3520RG 62/U TypePlenum
CATALOGNUMBER
AWG SIZE NOM. DCR
(Ω/M) (M=1000’)
INSULATIONMATERIAL
INCHES mm
SHIELD COVERAGE
NOM SHLD DCR
NOMINAL O.D.
NOMINALATTENUATION
VELOCITY OFPROPAGATION,
%
NOMINALIMPEDANCE,
Ω MHz dB/100'
NOMINALCAPACITANCEpF/ft pF/mINCHES mm
18 Ga.Solid BC6.5 V/M18 Ga.
Solid BC6.5 V/M18 Ga.
Solid CCS28.9 V/M
18 Ga.Solid CCS28.9 V/M
14 Ga.Solid CCS11.4 V/M
14 Ga.Solid CCS11.4 V/M
19 Ga.Solid BC8.1 V/M
20 Ga.(19 x 32)Stranded
TC9.5 V/M
20 Ga.Solid CCS45.9 V/M
20 Ga.Solid CCS45.9 V/M
20 Ga.Solid CCS45.9 V/M
22 Ga.Solid CCS54.7 V/M
CellularFluoropolymer
CellularFluoropolymer
CellularFluoropolymer
CellularFluoropolymer
CellularFluoropolymer
CellularFluoropolymer
CellularFluoropolymer
CellularFluoropolymer
CellularFluoropolymer
CellularFluoropolymer
CellularFluoropolymer
CellularFluoropolymer
0.170
0.170
0.170
0.170
0.280
0.280
0.102
0.100
0.135
0.135
0.145
0.145
4.318
4.318
4.318
4.318
7.11
7.11
2.59
2.54
3.429
3.429
3.68
3.56
100% Flexfoil®+61% TC Braid
2.3 V/M100% Flexfoil®+95% TC Braid
2.3 V/M100% Flexfoil®+60% AI. Braid
9.0 V/M(2) 100% Flexfoil®
1st Bonded(1) 60% AI. Braid(2) 40% AI. Braid
5.3 V/M
100% Flexfoil®Bonded +60% AI.
Braid 4.6 V/M(2) 100% Flexfoil®
1st Bonded(1) 60% AI. Braid(2) 40% AI. Braid
3.4 V/M
+95% TC Braid2.9 V/M
100% Flexfoil®+95% TC Braid
3.1 V/M
100% Flexfoil®+65% AI. Braid
10.7 V/M(2) 100% Flexfoil®
1st Bonded(1) 60% AI. Braid(2) 40% AI. Braid
6.3 V/M
+95% BC Braid1.9 V/M
+95% BC Braid1.9 V/M
86
86
86
86
82
82
82
78
84
84
82
84
75
75
75
75
75
75
50
50
75
75
75
93
11050
100200500
10001
1050
100200500
10002300
11050
100200500
1000145018002200
11050
100200500
10001
1050
100200500
10001
1050
100200500
10002300
11050
100200500
10001
1050
100200500
1000
0.300.661.502.103.105.007.300.30 0.661.502.103.105.007.30
12.200.150.471.091.592.353.946.197.458.309.180.401.302.803.906.009.50
13.500.601.302.904.206.10
10.0014.80
0.341.071.772.503.535.988.45
14.100.781.901.982.804.106.829.640.300.851.902.703.805.908.34
16.00
16.00
16.00
16.00
16.00
16.00
25.00
26.00
16.00
16.00
16.50
13.00
52.50
52.50
52.50
52.50
52.50
52.50
82.00
85.31
52.50
52.50
54.14
42.65
119
Electronics
Audio/Video & Broadcast Cable 9
General Cable offers avariety of Carol® Brand andHelix/HiTemp™ Brand wire andcable for audio/video,broadcast, traffic control anddirect burial applications. From field production cable,precision video coax andcamera cable to microphone,snake, guitar and speakercable, General Cable supportsthe increasingly demandingentertainment industry.
For extreme hard service,General Cable’s rubbermicrophone cables offer theultimate in performance andservice life. The rubber designsare highly flexible and designedto lie flat on studio floors, aswell as provide high impactand abrasion resistance.
For outdoor and cold weatherapplications, microphone cablejacketed with Carolprene®
provides the ultimate protectionagainst ozone, oil and ultravioletradiation.
These technicallysophisticated cables arerequired to contain sources ofinterference and to protectagainst difficulties where theyare unavoidable. In addition toproviding the needed electricalcharacteristics, the cables areproperly designed to handledemanding conditions, such asmicrophone hum, handlingnoise, crosstalk, electrostatichum, SCR noise and commonground noise—either on stage,in a studio or at a remote venue.
For more information onthese cables or for otherspecial applications, pleasecontact your General Cablesales representative.
Index Page
RG 59/U (RGB) Miniature Multi-Channel Precision Cable 131-132RG 59 Serial Digital Interface Cable 133-134Ultra Flexible, Low Impedance 4-Conductor “Star-Quad” Microphone Cable 135Ultra Flexible, Low Impedance 2-Conductor Microphone Cable 136Multi-Conductor,Spiral Shield 137
Multi-Conductor,Flexfoil® Shield 138
Multi-Conductor,Braid Shield 139
Multi-Conductor, Rubber,Braid Shield 140
Multi-Conductor,Carolprene®, Braid Shield 141
Special Audio,Communication &Instrumentation 142-144
CCTV Coaxial, TV Camera &Video Surveillance 145
Direct Burial, Audio& Communication 146-147
Analog Audio Snake Cable 148-149Digital Audio Snake Cable 150-151
Speaker Wire 152-153
Superflex®
Speaker Wire 154
Command Series®
Speaker Cable 155-157
Guitar/Instrument Cable 158
Index Page
SMPTE-311 Hybrid FiberOptic/Copper Camera Cable 120Electronic News Gathering/FieldProduction Camera Cable 121RG 6/U Multi-Channel Digital/Precision Cable 122-123RG 6 & RG 7 Serial DigitalInterface/Precision Cable 124RG 11 Serial Digital Interface(SDI) Precision Cable 125-126RG 59/U (RGB) Multi-ChannelDigital/Precision Cable 127RG 59 & RG 11 Camera Cable 128-129RG 59/U Precision andMiniature Cable 130
120
Audio/Video & Broadcast Cable Electronics
SMPTE-311 Hybrid Fiber Optic/Copper Camera Cable
Product Construction:Conductor:• Element #1: 4 Auxiliary Conductors (used as
two)Size: 20 AWG; Stranded Tinned
Annealed CopperInsulation: High-density Polyethylene OD:
0.060" Nom. (1.53mm)
• Element #2: 2 Single ConductorsSize: 24 AWG; Stranded Tinned
Annealed CopperInsulation: High-density Polyethylene:
0.045" Nom. (1.12mm)
• Element #3:Single Mode Fiber Optic
• Element #4:Strength Member in CoreSize: 16 AWG; Stranded Insulated
Galvanized Steel CableColor: WhiteOD: 0.083" Nom. (2.1mm)
Fillers:• Fibrillated Polypropylene as needed for
roundness
Binder:• Paper Tape 25% overlap
Braid Shield:• Flexibly designed Braid Shield with 85%
Nom. Coverage
Jacket:• Flexible PVC (HQA)
Temperature Range: -40˚C to +75˚CHumidity 0 to 95%
• TPR Ruggedized Outdoor Version
Jacket Marking:• HELIX/HITEMP P/N XXXXXX* SINGLE-MODE
FIBER OPTIC/ELECTRICAL HD CAMERA CABLE (RU) AWM STYLE 21059 80C 300V VW-1
Cable Weight:• 87.6 Lbs/Mft Nom. (130.8Kg/KM)
Performance:• Meets/exceeds SMPTE-311 M-1998
Connector:• LEMO Connector (call LEMO for more
information at 800.444.5366)• SMPTE Standard 304 Video Connector
Compliances:• UL Subject 758• AWM Style 21059
Packaging:• Please consult Customer Service for
packaging and color options
*XXXXXX - indicates part number
Element Number (1) Auxiliary Conductors (2) Signal Conductors (3) Single Mode Fiber Optic
35.29Ω/Km max @20˚C
43Ω/Km max @20˚C
10,000MΩ/Km max @20˚C
1750V RMS@20˚C, 60Hz for 1 min
300V Max
C1, C3-BlackC2, C4-White
Conductor DCR
DC loop Resistance
Insulation Resistance
Dielectric Strength
Voltage Rating
Color
97.5ΩKm max@20˚C
184ΩKm max@20˚C
10,000MΩKm max@20˚C
1750V RMS@20˚C, 60Hz for 1 min
300V Max
C1-RedC2-Gray
Mode Field Data
Cladding Data
Buffer Material
9.5+/-1 Micron
125+/-1 Micron
Thermoplastic
C1-BlueC2-Yellow
Cable Characteristics
CATALOGNUMBER
AUXILIARYCONDUCTOR SIGNAL COND.
OPTICAL FIBER STRENGTH
MEMBERSHIELD
742608
574608
(4) 20 AWG 26/34 StrandTinned Cu
High-density PolyethyleneInsul. O.D. 0.060"
(4) 20 AWG 26/34 StrandTinned Cu
High-density PolyethyleneInsul. O.D. 0.060"
(2) 25 AWG 7/33 Strand Tinned Cu
High-density Polyethylene Insul. O.D. 0.045"
(2) 25 AWG 7/33 Strand Tinned Cu
High-density Polyethylene Insul. O.D. 0.045"
(2) 9.5 MicronSingle-Mode
(2) 9.5 MicronSingle-Mode
14 AWG 19/27Strand Galvanized
Steel
14 AWG 19/27Strand Galvanized
Steel
95% BraidTinned Cu
95% BraidTinned Cu
JACKET
Flexible PVC(HQA)
Black 0.362" O.D. 9.20 mmRuggedized
Outdoor TPRBlack 0.362"
O.D. 9.20 mm
NOTE: General Cable manufactures the above cables in a wide range of alternate AWG sizes, pair counts and jacket colors.Please consult Customer Service for details.
TYPICAL CROSS SECTION
121
Electronics Audio/Video & Broadcast Cable
Electronic News Gathering/Field Production Camera Cable
Product Construction:Applications:• Ideal for TV broadcast and CCTV
applications• Suited for controlling, powering and
transmitting audio and video signals for TVcameras
• Additional uses include remote control,monitor and cue line systems
Features:• Provides excellent circuit isolation• Superior durability characteristics in a
variety of environmental conditions
Packaging and Jacket Colors:• Please consult Customer Service for
packaging and color options
CATALOGNUMBER
COAXIALCOMPONENT SIGNAL PAIR POWER PAIR
742605 1/C 25 AWG Stranded 7/33 Bare Copper
High-density Polyethylene Insulation90% Bare Copper Braid
PVC Jacket O.D. 0.175" Nom.
1/PR 24 AWGStranded 19/36 Bare
Copper Polyethylene
Insulation + Foil 24 AWG Drain
O.D. 0.140" Nom.
1/PR 22 AWGStranded 26/36 Bare
Copper PVC Insulation
O.D. 0.100" Nom.
JACKET
Matte Black“HQA” PVCO.D. .495"
Nom.
NOTE: General Cable manufactures the above cables in a wide range of alternate AWG sizes, pair counts and jacket colors.Please consult Customer Service for details.
122
Audio/Video & Broadcast Cable Electronics
RG 6/U Multi-Channel Digital/Precision Cable75 Ohm High-End Coaxial Cables for Exacting Video, Analog, Digital & Monitor Applications
Part No.& SafetyRatings
Cond.Size/Type
& DCR
InsulationType Nom.O.D. in/mm
Shield Type &DCR/KFt
Jacket & Nom.Dia. in/mm
Nom.Imp.Ohm
Nom.Vel. ofProp.
NominalCapacitance
pF/ft pF/m
Nominal Attenuation
MHz dB/ dB/100FT 100m
RG 6/U MULTI-CHANNEL DIGITAL/PRECISION, RISER RATED
RG 6/U PRECISION, CM RATED
395011-3UL CMR
c(UL) CMG75˚C/300V
395011-4UL CMR
c(UL) CMG75˚C/300V
395011-5UL CMR
c(UL) CMG75˚C/300V
395056UL CM
c(UL) CMG75˚C/300V
183/Cond.Solid BC
(6.5 Ohm)
184/Cond.Solid BC
(6.5 Ohm)
185/Cond.Solid BC
(6.5 Ohm)
18Solid BC
(6.7 Ohm)
Foam PEGas Injection0.180 / 4.57
Foam PEGas Injection0.180 / 4.57
Foam PEGas Injection0.180 / 4.57
Foam PEGas Injection0.180 / 4.57
Dual Foil+ 95% TinnedCopper Braid
Shield(2.8 Ohm)
Dual Foil+ 95% TinnedCopper Braid
Shield(2.8 Ohm)
Dual Foil+ 95% TinnedCopper Braid
Shield(2.8 Ohm)
Foam PEGas Injected.0.180 / 4.57
Inner:Flame-Retardant
PVC
Outer:TPE matte
0.685 / 17.40
Inner:Flame-Retardant
PVC
Outer:TPE matte
0.755 / 19.18
Inner:Flame-Retardant
PVC
Outer:TPE matte
0.860 / 21.85
Flame-RetardantPVC
0.272 / 6.91
16.2 53.2 75 83%
16.2 53.2 75 83%
16.2 53.2 75 83%
16.3 53.4 75 83%
1 0.24 0.793.6 0.45 1.4871.5 1.60 5.2588.5 1.75 5.74135 2.10 6.89180 2.42 7.94270 2.97 9.84360 3.43 11.15540 4.25 14.10750 5.00 16.401500 7.33 24.042250 9.14 29.983000 10.67 34.99
1 0.24 0.793.6 0.45 1.4871.5 1.60 5.2588.5 1.75 5.74135 2.10 6.89180 2.42 7.94270 2.97 9.84360 3.43 11.15540 4.25 14.10750 5.00 16.401500 7.33 24.042250 9.14 29.983000 10.67 34.99
1 0.24 0.793.6 0.45 1.4871.5 1.60 5.2588.5 1.75 5.74135 2.10 6.89180 2.42 7.94270 2.97 9.84360 3.43 11.15540 4.25 14.10750 5.00 16.401500 7.33 24.042250 9.14 29.983000 10.67 34.99
1 0.19 0.623.6 0.36 1.1810 0.65 2.1350 1.46 4.79
71.5 1.75 5.7388.5 2.03 6.67100 2.16 7.09135 2.51 8.23180 2.68 8.81200 2.83 9.29270 3.29 10.79360 4.32 14.16400 4.55 14.93540 5.29 17.35700 6.02 19.75750 6.23 20.44900 6.83 22.391000 7.19 23.601500 8.81 28.912250 10.79 35.413000 12.46 40.88
123
Electronics Audio/Video & Broadcast Cable
RG 6/U Multi-Channel Digital/Precision Cable75 Ohm High-End Coaxial Cables for Exacting Video, Analog, Digital & Monitor Applications
Part No.& SafetyRatings
Cond.Size/Type
& DCR
InsulationType Nom.O.D. in/mm
Shield Type &DCR/KFt
Jacket & Nom.Dia. in/mm
Nom.Imp.Ohm
Nom.Vel. ofProp.
NominalCapacitance
pF/ft pF/m
Nominal Attenuation
MHz dB/ dB/100FT 100m
RG 6/U PRECISION, PLENUM RATED495035UL CMP
c(UL) CMG75˚C/300V
495036UL CMP
c(UL) CMG150˚C/300V
18Solid BC
(6.7 Ohm)
18Solid BC
(6.7 Ohm)
Foam FEP0.170 / 4.32
Foam FEP0.170 / 4.32
+ 95% BareCopper Braid
(2.0 Ohm)
+ 95% BareCopper Braid
(2.0 Ohm)
Plenum PVC0.237 / 6.02
PVDF0.237 / 6.02
16.2 52.5 75 84%
16.1 53.0 75 84%
1 0.21 0.693.6 0.40 1.3110 0.65 2.1350 1.46 4.79
71.5 1.75 5.7388.5 1.92 6.30100 2.04 6.69135 2.37 7.78180 2.83 9.28200 2.98 9.78270 3.46 11.36360 4.23 13.88400 4.46 14.63540 5.18 17.00700 5.90 19.36750 6.11 20.04900 6.69 21.951000 7.05 23.141500 8.64 28.342250 10.58 34.713000 12.21 40.07
1 0.21 0.693.6 0.40 1.3110 0.65 2.1350 1.46 4.79
71.5 1.75 5.7388.5 1.92 6.30100 2.04 6.69135 2.37 7.78180 2.83 9.28200 2.98 9.78270 3.46 11.36360 4.23 13.88400 4.46 14.63540 5.18 17.00700 5.90 19.36750 6.11 20.04900 6.69 21.951000 7.05 23.141500 8.64 28.342250 10.58 34.713000 12.21 40.07
124
Audio/Video & Broadcast Cable Electronics
RG 6 & RG 7 Serial Digital Interface/Precision Cable75 Ohm High-End Coaxial Cables for Exacting Video, Analog & Digital Applications
Part No.& SafetyRatings
Cond.Size/Type
& DCR
InsulationType Nom.O.D. in/mm
Shield Type &DCR/KFt
Jacket & Nom.Dia. in/mm
Nom.Imp.Ohm
Nom.Vel. ofProp.
NominalCapacitance
pF/ft pF/m
Nominal Attenuation
MHz dB/ dB/100FT 100m
RG 6/U SERIAL DIGITAL INTERFACE (SDI)/PRECISION, RISER RATED
RG 6/U SERIAL DIGITAL INTERFACE (SDI)/PRECISION, PLENUM RATED
RG 7/U LOW LOSS, SERIAL DIGITAL INTERFACE (SDI)/PRECISION, CMR RATED
395011UL CMR
c(UL) CMG75˚C/300V
495025UL CMP
c(UL) CMP75˚C/300V
395047UL CMR
c(UL) CMG75˚C/300V
18Solid BC
(6.5 Ohm)
18Solid BC
(6.5 Ohm)
16Solid BC
(4.1 Ohm)
Foam PEGas Injection0.180 / 4.57
Foam FEP0.170 / 4.32
Foam PEGas Injection0.224 / 5.69
Dual Foil+ 95% TinnedCopper Braid
Shield(2.8 Ohm)
Dual Foil+ 95% TinnedCopper Braid
Shield(2.8 Ohm)
Dual Foil+ 95% TinnedCopper Braid(2.24 Ohm)
Flame-RetardantPVC
0.272 / 6.91
Plenum-PVC0.237 / 6.02
Flame-RetardantPVC
0.320 / 8.13
16.2 53.1 75 83%
16.1 53.0 75 84%
16.2 53.1 75 83%
1 0.24 0.793.6 0.45 1.4871.5 1.60 5.2588.5 1.75 5.74135 2.10 6.89180 2.42 7.94270 2.97 9.84360 3.43 11.15540 4.25 14.10750 5.00 16.401500 7.33 24.042250 9.14 29.983000 10.67 34.99
1 0.24 0.793.6 0.45 1.4871.5 1.78 5.8488.5 1.95 6.40135 2.40 7.87180 2.45 8.04270 2.75 9.02360 3.40 11.15540 4.00 13.12750 5.20 17.061500 6.36 20.862250 11.60 38.053000 13.70 44.94
1 0.18 0.593.6 0.36 1.1871.5 1.35 4.4388.5 1.49 4.89135 1.78 5.84180 2.06 6.76270 2.52 8.26360 2.87 9.41540 3.61 11.84750 4.28 14.031500 6.16 20.212250 7.65 25.093000 8.94 29.32
125
Electronics Audio/Video & Broadcast Cable
Part No.& SafetyRatings
Cond.Size/Type
& DCR
InsulationType Nom.O.D. in/mm
Shield Type &DCR/KFt
Jacket & Nom.Dia. in/mm
Nom.Imp.Ohm
Nom.Vel. ofProp.
NominalCapacitance
pF/ft pF/m
Nominal Attenuation
MHz dB/ dB/100FT 100m
RG 11/U SERIAL DIGITAL INTERFACE (SDI), EXTENDED DISTANCE, RISER RATED
RG 11/U SERIAL DIGITAL INTERFACE (SDI), EXTENDED DISTANCE, PLENUM RATED
RG 11/U SERIAL DIGITAL INTERFACE (SDI), EXTENDED DISTANCE, OUTDOOR RATED
RG-11/U SERIAL DIGITAL INTERFACE (SDI), EXTENDED DISTANCE, CM RATED
395029UL CMR
c(UL) CMG75˚C/300V
495027UL CMP
c(UL) CMP125˚C/300V
395057Outdoor
-65˚C to +80˚C300V
395058UL CM
c(UL) CMG75˚C / 300V
14Solid BC
(2.6 Ohm)
14Solid BC
(2.6 Ohm)
14Solid BC
(2.6 Ohm)
14Solid BC
(2.6 Ohm)
Foam PEGas Injection0.280 / 7.11
Foam FEP0.280 / 7.11
Foam PEGas Injection0.285 / 7.24
Foam PEGas Injection0.285 / 7.24
Dual Foil+ 95% TinnedCopper Braid
(1.5 Ohm)
Dual Foil+ 95% TinnedCopper Braid
Shield(1.5 Ohm)
+ 95% BareCopper Braid
(1.2 Ohm)
+ 95% BareCopper Braid
(1.2 Ohm)
Flame-RetardantPVC
0.405 / 10.29
PVDF0.348 / 8.84
PE0.405 / 10.29
Flame-RetardantPVC
0.405 / 10.29
16.2 53.1 75 83%
16.2 53.1 75 84%
16.2 52.5 75 84%
16.2 52.5 75 84%
1 0.15 0.493.6 0.28 0.9271.5 1.17 3.8488.5 1.31 4.29135 1.62 5.31180 1.87 6.13270 2.31 7.58360 2.67 8.76540 3.29 10.79750 3.89 12.761500 5.60 18.372250 6.94 22.763000 8.10 26.57
1 0.12 0.393.6 0.24 0.7971.5 1.12 3.6888.5 1.27 4.17135 1.63 5.35180 1.94 6.36270 2.49 8.17360 3.01 9.87540 3.89 12.76750 4.85 15.911500 7.88 25.452250 10.61 34.803000 12.35 40.51
1 0.17 0.563.6 0.32 1.0610 0.35 1.1550 0.90 2.95
71.5 1.08 3.5388.5 1.22 4.01100 1.30 4.27135 1.51 4.96180 1.80 5.91200 1.90 6.23270 2.21 7.24360 2.75 9.03400 2.90 9.51540 3.37 11.06700 3.84 12.59750 3.97 13.03900 4.35 14.271000 4.59 15.041500 5.62 18.432250 6.88 22.573000 7.94 26.06
1 0.17 0.563.6 0.32 1.0610 0.35 1.1550 0.90 2.95
71.5 1.08 3.5388.5 1.22 4.01100 1.30 4.27135 1.51 4.96180 1.80 5.91200 1.90 6.23270 2.21 7.24360 2.75 9.03400 2.90 9.51540 3.37 11.06700 3.84 12.59750 3.97 13.03900 4.35 14.271000 4.59 15.041500 5.62 18.432250 6.88 22.573000 7.94 26.06
RG 11 Serial Digital Interface (SDI) Precision Cable Extended-Distance, 75 Ohm High-End Coaxial Cables for Exacting Video, Analog & Digital Applications
126
Audio/Video & Broadcast Cable Electronics
RG 11 Serial Digital Interface (SDI) Precision Cable Extended-Distance, 75 Ohm High-End Coaxial Cables for Exacting Video, Analog & Digital Applications
Part No.& SafetyRatings
Cond.Size/Type
& DCR
InsulationType Nom.O.D. in/mm
Shield Type &DCR/KFt
Jacket & Nom.Dia. in/mm
Nom.Imp.Ohm
Nom.Vel. ofProp.
NominalCapacitance
pF/ft pF/m
Nominal Attenuation
MHz dB/ dB/100FT 100m
RG 11/U SERIAL DIGITAL INTERFACE (SDI), EXTENDED DISTANCE, PLENUM RATED495015UL CMP
c(UL) CMP125˚C / 300V
495016UL CMP
c(UL) CMP125˚C / 300V
14Solid BC
(2.6 Ohm)
14Solid BC
(2.6 Ohm)
Foam FEP0.280 / 7.11
Foam FEP0.280 / 7.11
+ 95% BareCopper Braid
(1.2 Ohm)
Dual Foil+ 60% AL Braid
(3.0 Ohm)
PVDF0.351 / 8.92
PVDF0.351 / 8.92
16.2 52.5 75 84%
16.2 53.1 75 84%
1 0.17 0.563.6 0.32 1.0610 0.35 1.1550 0.90 2.95
71.5 1.08 3.5388.5 1.22 4.01100 1.30 4.27135 1.51 4.96180 1.80 5.91200 1.90 6.23270 2.21 7.24360 2.75 9.03400 2.90 9.51540 3.37 11.06700 3.84 12.59750 3.97 13.03900 4.35 14.271000 4.59 15.041500 5.62 18.432250 6.88 22.573000 7.94 26.06
1 0.15 0.493.6 0.28 0.9310 0.40 1.3150 1.00 3.28
71.5 1.20 3.9288.5 1.41 4.63100 1.50 4.92135 1.74 5.72180 2.09 6.85200 2.20 7.22270 2.56 8.39360 3.13 10.27400 3.30 10.83540 3.83 12.58700 4.37 14.32750 4.52 14.83900 4.95 16.241000 5.22 17.121500 6.39 20.972250 7.83 25.683000 9.04 29.65
Part No.& SafetyRatings
Cond.Size/Type
& DCR
InsulationType Nom.O.D. in/mm
Shield Type &DCR/KFt
Jacket & Nom.Dia. in/mm
Nom.Imp.Ohm
Nom.Vel. ofProp.
NominalCapacitance
pF/ft pF/m
Nominal Attenuation
MHz dB/ dB/100FT 100m
127
Electronics Audio/Video & Broadcast Cable
RG 59/U (RGB) Multi-Channel Digital/Precision Cable75 Ohm High-End Coaxial Cables for Exacting Video, Analog Digital & Monitor Applications
RG 59/U MINI SERIAL DIGITAL INTERFACE (SDI), PRECISION COAX, RISER RATED
RG 59/U SERIAL DIGITAL INTERFACE (SDI), PRECISION COAX, PLENUM RATED
395031-3UL CMR
c(UL) CMG75˚C / 300V
395031-4UL CMR
c(UL) CMG75˚C / 300V
395031-5UL CMR
c(UL) CMG75˚C / 300V
395025-3UL CMR
c(UL) CMG75˚C / 300V
395025-4UL CMR
c(UL) CMG75˚C / 300V
395025-5UL CMR
c(UL) CMG75˚C / 300V
395025-10UL CMR
c(UL) CMG75˚C / 300V
233/Cond.Solid BC
(20.1 Ohm)
234/Cond.Solid BC
(20.1 Ohm)
235/Cond.Solid BC
(20.1 Ohm)
203/Cond.Solid BC
(10.5 Ohm)
204/Cond.Solid BC
(10.5 Ohm)
205/Cond.Solid BC
(10.5 Ohm)
2010/Cond.Solid BC
(10.5 Ohm)
Foam PEGas Injection0.102 / 2.59
Foam PEGas Injection0.102 / 2.59
Foam PEGas Injection0.102 / 2.59
Foam PEGas Injection0.146 / 3.71
Foam PEGas Injection0.146 / 3.71
Foam PEGas Injection0.146 / 3.71
Foam PEGas Injection0.146 / 3.71
Dual Foil+ 95% TinnedCopper Braid
Shield(7.6 Ohm)
Dual Foil+ 95% TinnedCopper Braid
Shield(7.6 Ohm)
Dual Foil+ 95% TinnedCopper Braid
Shield(7.6 Ohm)
Dual Foil+ 95% TinnedCopper Braid
Shield(3.5 Ohm)
Dual Foil+ 95% TinnedCopper Braid
Shield(3.5 Ohm)
Dual Foil+ 95% TinnedCopper Braid
Shield(3.5 Ohm)
Dual Foil+ 95% TinnedCopper Braid
Shield(3.5 Ohm)
Inner:Flame-Retardant
PVC
Outer:TPE matte
0.415 / 10.58
Inner:Flame-Retardant
PVC
Outer:TPE matte
0.460 / 11.68
Inner:Flame-Retardant
PVC
Outer:TPE matte
0.510 / 12.95
Inner:Flame-Retardant
PVC
Outer:TPE matte
0.610 / 15.49
Inner:Flame-Retardant
PVC
Outer:TPE matte
0.670 / 17.04
Inner:Flame-Retardant
PVC
Outer:TPE matte
0.745 / 18.87
Inner:Flame-Retardant
PVC
Outer:TPE matte
1.110 / 28.19
16.5 54.1 75 83%
16.5 54.1 75 83%
16.5 54.1 75 83%
16.3 52.4 75 83%
16.3 52.4 75 83%
16.3 52.4 75 83%
16.3 52.4 75 83%
1 0.39 1.283.6 0.78 2.5671.5 3.06 10.0488.5 3.16 10.36135 3.81 12.50180 4.38 14.37270 5.40 17.71360 6.20 20.34540 7.70 25.26750 9.59 31.451500 13.0 42.642250 16.0 52.483000 18.50 60.68
1 0.39 1.283.6 0.78 2.5671.5 3.06 10.0488.5 3.16 10.36135 3.81 12.50180 4.38 14.37270 5.40 17.71360 6.20 20.34540 7.70 25.26750 9.59 31.451500 13.0 42.642250 16.0 52.483000 18.50 60.68
1 0.39 1.283.6 0.78 2.5671.5 3.06 10.0488.5 3.16 10.36135 3.81 12.50180 4.38 14.37270 5.40 17.71360 6.20 20.34540 7.70 25.26750 9.59 31.451500 13.0 42.642250 16.0 52.483000 18.50 60.68
1 0.29 0.953.6 0.55 1.8171.5 2.10 6.8988.5 2.20 7.22135 2.70 8.86180 3.10 10.17270 3.80 12.46360 4.40 14.50540 5.47 17.94750 6.50 21.321500 9.30 30.502250 11.51 37.753000 13.31 43.66
1 0.29 0.953.6 0.55 1.8171.5 2.10 6.8988.5 2.20 7.22135 2.70 8.86180 3.10 10.17270 3.80 12.46360 4.40 14.50540 5.47 17.94750 6.50 21.321500 9.30 30.502250 11.51 37.753000 13.31 43.66
1 0.29 0.953.6 0.55 1.8171.5 2.10 6.8988.5 2.20 7.22135 2.70 8.86180 3.10 10.17270 3.80 12.46360 4.40 14.50540 5.47 17.94750 6.50 21.321500 9.30 30.502250 11.51 37.753000 13.31 43.66
1 0.29 0.953.6 0.55 1.8171.5 2.10 6.8988.5 2.20 7.22135 2.70 8.86180 3.10 10.17270 3.80 12.46360 4.40 14.50540 5.47 17.94750 6.50 21.321500 9.30 30.502250 11.51 37.753000 13.31 43.66
RG 59/U FLEXIBLE ALL-WEATHER RATED
RG 59/U CM RATED
128
Audio/Video & Broadcast Cable Electronics
RG 59 & RG 11 Camera Cable75 Ohm High-End Triaxial Cables for Powered Video Applications
RG 59/U ULTRA FLEX ALL-WEATHER RATED
RG 11/U OUTDOOR EXTENDED DISTANCE, OUTDOOR RATED
Part No.& SafetyRatings
Cond.Size/Type
& DCR
InsulationType Nom.O.D. in/mm
Shield Type &DCR/KFt
Jacket & Nom.Dia. in/mm
Nom.Imp.Ohm
Nom.Vel. ofProp.
NominalCapacitance
pF/ft pF/m
Nominal Attenuation
MHz dB/ dB/100FT 100m
395007Outdoor
-35˚C to +80˚C300V
395040UL CM
c(UL) CMG75˚C / 300V
395006Outdoor
-35˚C to +80˚C300V
395041Outdoor
-65˚C to +80˚C300V
20Solid BC
(10.2 Ohm)
20Solid BC
(10.2 Ohm)
21Stranded
(19/33) BC(12.0 Ohm)
14Solid BC
(10.2 Ohm)
Foam PEGas Injection0.146 / 3.71
Foam PEGas Injection0.146 / 3.71
Foam PE0.146 / 3.71
Foam PEGas Injection0.285 / 7.24
Inner: 95% BC Braid
(2.6 Ohm)
Outer: 95% BC Braid
(2.6 Ohm)
Inner: 95% BC Braid
(2.6 Ohm)
Outer: 95% BC Braid
(2.6 Ohm)
Inner: 95% BC Braid
(2.6 Ohm)
Outer: 95% BC Braid
(2.6 Ohm)
Inner: 95% BC Braid
(1.6 Ohm)
Outer: 95% BC Braid
(1.6 Ohm)
Inner: PE
Outer: TPE0.360 / 9.15
Inner: PVC
Outer: Flame-Retardant
PVC0.360 / 9.15
Inner: PE
Outer: TPE0.360 / 9.15
Inner: LD-PE
Outer: PE
0.475 / 12.07
16.2 53.1 75 83%
16.2 53.1 75 83%
17.0 55.7 75 78%
16.0 52.5 75 83%
1 0.29 0.953.6 0.55 1.8110 0.93 3.0550 1.73 5.68
71.5 2.07 6.7988.5 2.30 7.56100 2.45 8.04135 2.85 9.34180 3.28 10.77200 3.46 11.35270 4.02 13.19360 4.65 15.25400 4.90 16.08540 5.69 18.68700 6.99 22.93750 7.24 23.74900 7.92 25.991000 8.35 27.401500 10.23 33.552250 12.53 41.093000 14.46 47.45
1 0.29 0.953.6 0.55 1.8110 0.93 3.0550 1.73 5.68
71.5 2.07 6.7988.5 2.30 7.56100 2.45 8.04135 2.85 9.34180 3.28 10.77200 3.46 11.35270 4.02 13.19360 4.65 15.25400 4.90 16.08540 5.69 18.68700 6.99 22.93750 7.24 23.74900 7.92 25.991000 8.35 27.401500 10.23 33.552250 12.53 41.093000 14.46 47.45
1 0.35 1.153.6 0.66 2.1810 1.10 3.6150 1.77 5.81
71.5 2.12 6.9488.5 2.35 7.72100 2.50 8.20135 2.90 9.53180 3.36 11.02200 3.54 11.61270 4.11 13.50360 4.74 15.56400 5.00 16.41540 5.81 19.06700 7.36 24.15750 7.62 25.00900 8.35 27.401000 8.80 28.871500 10.78 35.362250 13.20 43.313000 15.24 50.01
1 0.14 0.463.6 0.27 0.8710 0.45 1.4850 0.92 3.02
71.5 1.10 3.6188.5 1.22 4.01100 1.30 4.27135 1.51 4.96180 1.75 5.73200 1.84 6.04270 2.14 7.01360 2.47 8.09400 2.60 8.53540 3.02 9.91700 3.76 12.34750 3.89 12.77900 4.27 14.011000 4.50 14.761500 5.51 18.082250 6.75 22.153000 7.79 25.57
129
Electronics Audio/Video & Broadcast Cable
RG 59 & RG 11 Camera Cable75 Ohm High-End Triaxial Cables for Powered Video Applications
Part No.& SafetyRatings
Cond.Size/Type
& DCR
InsulationType Nom.O.D. in/mm
Shield Type &DCR/KFt
Jacket & Nom.Dia. in/mm
Nom.Imp.Ohm
Nom.Vel. ofProp.
NominalCapacitance
pF/ft pF/m
Nominal Attenuation
MHz dB/ dB/100FT 100m
RG 11/U EXTENDED DISTANCE, CM RATED
RG 11/U FLEXIBLE ALL-WEATHER RATED
395028UL CM
c(UL) CMG75˚C / 300V
395042UL CM
c(UL) CMG75˚C / 300V
395024Outdoor
-35˚C to +80˚C300V
14Solid BC
(2.6 Ohm)
14Stranded
(19/27) BC(3.0 Ohm)
14Stranded
(19/27) BC(3.0 Ohm)
Foam PEGas Injection0.285 / 7.24
Foam PE0.314 / 7.98
Foam PE0.314 / 7.98
Inner:95% BC Braid
(1.6 Ohm)
Outer:95% BC Braid
(1.6 Ohm)
Inner:95% BC Braid
(1.6 Ohm)
Outer:95% BC Braid
(1.6 Ohm)
Inner:95% BC Braid
(1.6 Ohm)
Outer:95% BC Braid
(1.6 Ohm)
Inner: PVC
Outer:Flame-Retardant
PVC0.475 / 12.07
Inner: TPE
Outer:Flame-Retardant
PVC0.520 / 13.21
Inner: LD-PE
Outer: TPE0.520 / 13.21
16.0 52.5 75 83%
16.5 54.1 75 78%
17.5 57.4 75 78%
1 0.14 0.463.6 0.27 0.8710 0.45 1.4850 0.92 3.02
71.5 1.10 3.6188.5 1.22 4.01100 1.30 4.27135 1.51 4.96180 1.75 5.73200 1.84 6.04270 2.14 7.01360 2.47 8.09400 2.60 8.53540 3.02 9.91700 3.76 12.34750 3.89 12.77900 4.27 14.011000 4.50 14.761500 5.51 18.082250 6.75 22.153000 7.79 25.57
1 0.14 0.463.6 0.27 0.8710 0.45 1.4850 1.00 3.28
71.5 1.20 3.9288.5 1.35 4.44100 1.44 4.72135 1.67 5.49180 2.00 6.57200 2.11 6.92270 2.45 8.04360 2.91 9.56400 3.07 10.07540 3.57 11.70700 4.25 13.94750 4.40 14.43900 4.95 16.241000 5.27 17.291500 6.45 21.182250 7.91 25.943000 9.13 29.95
1 0.14 0.463.6 0.27 0.8710 0.45 1.4850 1.00 3.28
71.5 1.20 3.9288.5 1.35 4.44100 1.44 4.72135 1.67 5.49180 2.00 6.57200 2.11 6.92270 2.45 8.04360 2.91 9.56400 3.07 10.07540 3.57 11.70700 4.25 13.94750 4.40 14.43900 4.95 16.241000 5.27 17.291500 6.45 21.182250 7.91 25.943000 9.13 29.95
130
Audio/Video & Broadcast Cable Electronics
RG 59/U Precision & Miniature Cable75 Ohm High-End Coaxial Cables for Video, Analog and Digital Applications
Part No.& SafetyRatings
Cond.Size/Type
& DCR
InsulationType Nom.O.D. in/mm
Shield Type &DCR/KFt
Jacket & Nom.Dia. in/mm
Nom.Imp.Ohm
Nom.Vel. ofProp.
NominalCapacitance
pF/ft pF/m
Nominal Attenuation
MHz dB/ dB/100FT 100m
RG 59/U MINIATURE, RISER RATED
RG 59/U FLEXIBLE MINIATURE, RISER RATED
RG 59/U OUTDOOR RATED
RG 59/U CM RATED
RG 59/U PLENUM RATED
395035UL CM
c(UL) CMG75˚C / 300V
395032UL CMR
c(UL) CMG75˚C / 300V
395021Outdoor
-65˚C/+80˚C300V
395030UL CM
c(UL) CMH75˚C / 300V
495028UL CMP
c(UL) CMP75˚C / 300V
495044UL CMP
c(UL) CMP150˚C / 300V
26Stranded BC
(7/34)(39.7 Ohm)
25Stranded BC
(7/33)(30.0 Ohm)
23Stranded BC
(7/31)(20.1 Ohm)
20Solid BC
(10.5 Ohm)
20Solid BC
(10.5 Ohm)
20Solid BC
(10.5 Ohm)
Foam PE0.089 / 2.26
Foam PE0.099 / 2.51
Solid PE0.146 / 3.71
Foam PEGas Injection0.146 / 3.71
Foam PE0.135 / 3.43
Foam FEP0.135 / 3.43
Flame-RetardantPVC
.146 / 3.71
Flame-RetardantPVC
.150 / 3.81
Polyethylene0.220 / 5.59
Flame-RetardantPVC
0.242 / 6.15
Plenum-PVC0.193 / 5.0
PVDF0.193 / 5.00
17.3 56.74 75 78%
17.2 56.4 75 78%
19.5 63.96 75 66%
16.2 53.2 75 83%
16.0 52.5 75 84%
16.0 52.5 75 84%
1 0.56 1.8410 1.48 4.8550 3.20 10.49100 5.18 16.99200 6.95 22.79400 9.36 30.70700 13.10 42.97900 14.98 49.131000 15.79 51.79
1 0.41 1.3510 1.31 4.3050 2.94 9.64100 4.18 13.71200 5.97 19.58400 8.56 28.10700 11.50 37.72900 13.14 43.101000 13.91 45.62
1 0.35 1.153.6 0.60 1.9771.5 3.30 10.8288.5 3.75 12.30135 4.65 15.25270 6.68 21.91360 7.77 25.48750 11.50 37.721000 13.43 44.05
1 0.17 0.5510 0.76 2.4950 1.80 5.90100 2.60 8.53200 3.80 12.46400 5.37 17.61
1 0.24 0.8210 1.41 2.6350 1.83 6.02100 2.64 8.68200 3.84 12.61400 5.64 18.49
1 0.24 0.8210 1.41 2.6350 1.83 6.02100 2.64 8.68200 3.84 12.61400 5.64 18.49
Dual Foil95% TinnedCopper Braid
Shield(8.6 Ohm)
95% TinnedCopper Braid
Shield(6.0 Ohm)
95% TinnedCopper Braid
Shield(4.2 Ohm)
95% BareCopper Braid
Shield(2.7 Ohm)
95% BareCopper Braid
Shield(2.7 Ohm)
95% BareCopper Braid
Shield(2.7 Ohm)
131
Electronics Audio/Video & Broadcast Cable
RG 59/U (RGB) Miniature Multi-Channel Precision Cable75 Ohm High-End Coaxial Cables for Video, Analog & Monitor Applications
Part No.& SafetyRatings
Cond.Size/Type
& DCR
InsulationType Nom.O.D. in/mm
Shield Type &DCR/KFt
Jacket & Nom.Dia. in/mm
Nom.Imp.Ohm
Nom.Vel. ofProp.
NominalCapacitance
pF/ft pF/m
Nominal Attenuation
MHz dB/ dB/100FT 100m
RG 59/U (RGB) CM/CMR RATED395035-3
c(UL) CMGUL CMR
75˚C / 300V
395035-4UL CM
c(UL) CMG75˚C / 300V
395035-5UL CM
c(UL) CMG75˚C / 300V
263/Cond.
Stranded BC(7/34)
(39.7 Ohm)
264/Cond.
Stranded BC(7/34)
(39.7 Ohm)
265/Cond.
Stranded BC(7/34)
(39.7 Ohm)
Foam PE0.089 / 2.26
Foam PE0.089 / 2.26
Foam PE0.089 / 2.26
Inner: Flame-Retardant
PVC
Outer:TPE matte
0.480 / 12.19
Inner: Flame-Retardant
PVC
Outer:TPE matte
Inner: Flame-Retardant
PVC
Outer:TPE matte
17.3 56.74 75 78%
17.3 56.74 75 78%
17.3 56.74 75 78%
1 0.56 1.843.6 1.06 3.4910 1.48 4.8650 3.20 10.50
71.5 3.95 12.9588.5 4.87 15.99100 5.18 17.00135 6.02 19.75180 6.59 21.63200 6.95 22.80270 8.08 26.49360 8.88 29.13400 9.36 30.71540 10.88 35.68700 13.10 42.98750 13.56 44.49900 14.98 49.151000 15.79 51.811500 19.34 63.452250 23.69 77.713000 27.35 89.73
1 0.56 1.843.6 1.06 3.4910 1.48 4.8650 3.20 10.50
71.5 3.95 12.9588.5 4.87 15.99100 5.18 17.00135 6.02 19.75180 6.59 21.63200 6.95 22.80270 8.08 26.49360 8.88 29.13400 9.36 30.71540 10.88 35.68700 13.10 42.98750 13.56 44.49900 14.98 49.151000 15.79 51.811500 19.34 63.452250 23.69 77.713000 27.35 89.73
1 0.56 1.843.6 1.06 3.4910 1.48 4.8650 3.20 10.50
71.5 3.95 12.9588.5 4.87 15.99100 5.18 17.00135 6.02 19.75180 6.59 21.63200 6.95 22.80270 8.08 26.49360 8.88 29.13400 9.36 30.71540 10.88 35.68700 13.10 42.98750 13.56 44.49900 14.98 49.151000 15.79 51.811500 19.34 63.452250 23.69 77.713000 27.35 89.73
Dual Foil+ 95% TinnedCopper Braid
Shield(8.6 Ohm)
Dual Foil+ 95% TinnedCopper Braid
Shield(8.6 Ohm)
Dual Foil+ 95% TinnedCopper Braid
Shield(8.6 Ohm)
132
Audio/Video & Broadcast Cable Electronics
RG 59/U (RGB) Miniature Multi-Channel Precision Cable75 Ohm High-End Coaxial Cables for Video, Analog & Monitor Applications
Part No.& SafetyRatings
Cond.Size/Type
& DCR
InsulationType Nom.O.D. in/mm
Shield Type &DCR/KFt
Jacket & Nom.Dia. in/mm
Nom.Imp.Ohm
Nom.Vel. ofProp.
NominalCapacitance
pF/ft pF/m
Nominal Attenuation
MHz dB/ dB/100FT 100m
RG 59/U (RGB) FLEXIBLE CM/CMR RATED395032-3UL CMR
C(UL) CMG75˚C / 300V
395032-4UL CMR
c(UL) CMG75˚C / 300V
395032-5UL CMR
c(UL) CMG75˚C / 300V
253/Cond.
Stranded BC(7/33)
(30.0 Ohm)
254/Cond.
Stranded BC(7/33)
(30.0 Ohm)
255/Cond.
Stranded BC(7/33)
(30.0 Ohm)
Foam PE0.099 / 2.51
Foam PE0.099 / 2.51
Foam PE0.099 / 2.51
Inner: Flame-Retardant
PVC
Outer:TPE matte
0.435 / 11.05
Inner: Flame-Retardant
PVC
Outer:TPE matte
0.480 / 12.19
Inner: Flame-Retardant
PVC
Outer:TPE matte
0.480 / 12.19
17.3 56.74 75 78%
17.3 56.74 75 78%
17.3 56.74 75 78%
1 0.41 1.353.6 0.78 2.5510 1.31 4.3050 2.94 9.65
71.5 3.52 11.5488.5 3.93 12.90100 4.18 13.71135 4.86 15.93180 5.66 18.58200 5.97 19.59270 6.94 22.76360 8.12 26.64400 8.56 28.09540 9.95 32.63700 11.50 37.73750 11.90 39.06900 13.14 43.111000 13.91 45.641500 17.04 55.902250 20.87 68.463000 24.09 79.05
1 0.41 1.353.6 0.78 2.5510 1.31 4.3050 2.94 9.65
71.5 3.52 11.5488.5 3.93 12.90100 4.18 13.71135 4.86 15.93180 5.66 18.58200 5.97 19.59270 6.94 22.76360 8.12 26.64400 8.56 28.09540 9.95 32.63700 11.50 37.73750 11.90 39.06900 13.14 43.111000 13.91 45.641500 17.04 55.902250 20.87 68.463000 24.09 79.05
1 0.41 1.353.6 0.78 2.5510 1.31 4.3050 2.94 9.65
71.5 3.52 11.5488.5 3.93 12.90100 4.18 13.71135 4.86 15.93180 5.66 18.58200 5.97 19.59270 6.94 22.76360 8.12 26.64400 8.56 28.09540 9.95 32.63700 11.50 37.73750 11.90 39.06900 13.14 43.111000 13.91 45.641500 17.04 55.902250 20.87 68.463000 24.09 79.05
95% TinnedCopper Braid
Shield(6.0 Ohm)
95% TinnedCopper Braid
Shield(6.0 Ohm)
95% TinnedCopper Braid
Shield(6.0 Ohm)
133
Electronics Audio/Video & Broadcast Cable
Part No.& SafetyRatings
Cond.Size/Type
& DCR
InsulationType Nom.O.D. in/mm
Shield Type &DCR/KFt
Jacket & Nom.Dia. in/mm
Nom.Imp.Ohm
Nom.Vel. ofProp.
NominalCapacitance
pF/ft pF/m
Nominal Attenuation
MHz dB/ dB/100FT 100m
RG 59/U MINI SERIAL DIGITAL INTERFACE (SDI)/PRECISION COAX, RISER RATED
RG 59/U SERIAL DIGITAL INTERFACE (SDI)/PRECISION COAX, RISER RATED
RG 59/U SERIAL DIGITAL INTERFACE (SDI)/PRECISION COAX, OUTDOOR RATED
395036UL CMR
c(UL) CMG75˚C / 300V
395031UL CMR
c(UL) CMG75˚C / 300V
395025UL CMR
c(UL) CMG75˚C / 300V
395010UL CMR
c(UL) CMG75˚C / 300V
395013Outdoor
-65˚C to +80˚C/ 300V
25(19/37) BC(27.4 Ohm)
23Solid BC
(20.1 Ohm)
20Solid BC
(10.5 Ohm)
20Solid BC
(10.5 Ohm)
20Solid BC
(10.5 Ohm)
Foam PEGas Injection0.094 / 2.38
Foam PEGas Injection0.102 / 2.59
Foam PEGas Injection0.146 / 3.71
Solid PE0.198 / 5.03
Solid PE0.198 / 5.03
Flame-RetardantPVC
0.150 / 3.81
Flame-RetardantPVC
0.159 / 4.04
Flame-RetardantPVC
0.242 / 6.15
Flame-RetardantPVC
0.305 / 7.75
Polyethylene 0.305 / 7.75
16.5 54.1 75 82%
16.5 54.1 75 83%
16.3 53.4 75 83%
20.5 67.24 75 66%
20.5 67.24 75 66%
1 0.43 1.413.6 0.95 3.1271.5 3.96 12.9988.5 4.10 13.45135 5.00 16.40180 5.80 19.02270 7.10 23.29360 8.20 26.90540 10.10 33.13750 11.98 39.291500 16.28 53.392250 20.73 67.993000 23.48 77.01
1 0.39 1.283.6 0.78 2.5671.5 3.06 10.0488.5 3.16 10.36135 3.81 12.50180 4.38 14.37270 5.40 17.71360 6.20 20.34540 7.70 25.26750 9.59 31.451500 13.0 42.642250 16.0 52.483000 18.50 60.68
1 0.29 0.953.6 0.55 1.8171.5 2.10 6.8988.5 2.20 7.22135 2.70 8.86180 3.10 10.17270 3.80 12.46360 4.40 14.50540 5.47 17.94750 6.50 21.321500 9.30 30.502250 11.51 37.753000 13.31 43.66
1 0.24 0.793.6 0.46 1.5110 0.77 2.5250 1.76 5.79
71.5 2.11 6.9288.5 2.35 7.71100 2.50 8.20135 2.94 9.65180 3.42 11.22200 3.60 11.83270 4.23 13.88360 4.94 16.21400 5.21 17.08540 6.16 20.21700 7.12 23.36750 7.37 24.18900 9.15 30.041000 9.65 31.661500 11.82 38.782250 14.48 47.493000 16.71 54.84
1 0.24 0.793.6 0.46 1.5110 0.77 2.5250 1.76 5.79
71.5 2.11 6.9288.5 2.35 7.71100 2.50 8.20135 2.94 9.65180 3.42 11.22200 3.60 11.83270 4.23 13.88360 4.94 16.21400 5.21 17.08540 6.16 20.21700 7.12 23.36750 7.37 24.18900 9.15 30.041000 9.65 31.661500 11.82 38.782250 14.48 47.493000 16.71 54.84
Dual Foil+ 95% TinnedCopper Braid
Shield(5.4 Ohm)
Dual Foil+ 95% TinnedCopper Braid
Shield(7.6 Ohm)
Dual Foil+ 95% TinnedCopper Braid
Shield(3.5 Ohm)
Dual Braid+ 98% TinnedCopper Braid
Shield(1.1 Ohm)
Dual Braid+ 98% TinnedCopper Braid
Shield(1.1 Ohm)
RG 59 Serial Digital Interface Cable75 Ohm High-End Coaxial Cables for Video, Analog & Digital Applications
134
Audio/Video & Broadcast Cable Electronics
RG 59 Serial Digital Interface Cable75 Ohm High-End Coaxial Cables for Video, Analog & Digital Applications
Part No.& SafetyRatings
Cond.Size/Type
& DCR
InsulationType Nom.O.D. in/mm
Shield Type &DCR/KFt
Jacket & Nom.Dia. in/mm
Nom.Imp.Ohm
Nom.Vel. ofProp.
NominalCapacitance
pF/ft pF/m
Nominal Attenuation
MHz dB/ dB/100FT 100m
RG 59/U SERIAL DIGITAL INTERFACE (SDI)/PRECISION COAX, PLENUM RATED495023UL CMP
C(UL) CMP75˚C / 300V
495010UL CMP
C(UL) CMP150˚C / 300V
20Solid BC
(10.5 Ohm)
20Solid BC
(10.5 Ohm)
Foam FEP0.135 / 3.43
Solid FEP0.188 / 4.78
Plenum - PVC0.199 / 5.05
PVDF0.276 / 7.01
16.1 53.0 75 84%
19.0 62.32 75 69%
1 0.29 0.953.6 0.62 2.0310 1.03 3.3950 1.88 6.17
71.5 2.25 7.3888.5 2.35 7.71100 2.50 8.20135 3.20 10.50180 3.65 11.98200 3.85 12.62270 4.55 14.93360 5.25 17.23400 5.53 18.16540 6.40 21.00700 7.16 23.49750 7.41 24.31900 8.12 26.631000 8.56 28.071500 12.80 42.002250 17.50 57.423000 21.90 71.85
1 0.25 0.823.6 0.48 1.5710 0.80 2.6250 2.08 6.83
71.5 2.49 8.1788.5 2.81 9.22100 2.99 9.80135 3.63 11.91180 4.46 14.63200 4.70 15.42270 5.64 18.50360 6.84 22.44400 7.21 23.66540 8.97 29.43700 10.91 35.79750 11.29 37.04900 13.18 43.231000 13.89 45.571500 17.01 55.822250 20.84 68.363000 24.06 78.93
Dual Foil+ 95% TinnedCopper Braid
Shield(3.2 Ohm)
Dual Braid+ 98% TinnedCopper Braid
Shield(0.93 Ohm)
135
Electronics Audio/Video & Broadcast Cable
Ultra Flexible, Low Impedance 4-Conductor “Star-Quad”Microphone Cable
Product Construction:Conductor:• 22 or 24 AWG stranded bare copper• 4-conductor, double-balanced pairing
Insulation:• Polyethylene
Shield:• 95% flexible braid, tinned copper
Jacket:• High Quality Audio (HQA) PVC, matte black• Superior flexibility
Applications:• Digital audio interfaces• High-end microphones• All line-level signals
Features:• Offers high conductor flexibility• “Star Quad” XLR connection* provides
common mode rejection at each pin, greatlyreducing induced noise levels andinterference
Packaging and Jacket Colors:• Please consult Customer Service for
packaging and color options
* Star Quad XLR connection is accomplished byconnecting the two white conductors to one XLR pinand the two blue conductors to the other XLR pin.
CATALOGNUMBER
CONDUCTORINSULATION
& O.D.SHIELD(COV.) JACKET
& O.D.WT.#/M’
IMPEDOHMS
CAPACpF/ft
743722
743702
743703
743731“mini”
4/C 22 AWG Stranded26/36 Bare Copper
4/C 24 AWG Stranded40/40 Bare Copper
4/C 24 AWG Stranded40/40 Bare Copper
4/C 24 AWG Stranded30/40 Bare Cu
Polyethylene0.062"
Polyethylene0.056"
Polyethylene0.056"
Polyethylene0.043"
Braid 95% Tinned Copper
Braid 95% Tinned Copper
Braid & Drain 95% Tinned Copper
Braid 95% Tinned Copper
“HQA” PVC 0.255"Nom. Black
“HQA” PVC 0.237"Nom. Black
“HQA” PVC 0.237"Nom. Black
“HQA” PVC 0.193"Nom. Black
43
35
37
24
44
48
48
48
46
39
39
39
136
Audio/Video & Broadcast Cable Electronics
Product Construction:Conductor:• 20 - 24 AWG stranded bare copper• Twisted pairs
Insulation:• PVC or Polyethylene
Shield:• Braid or Spiral, Bare or Tinned Copper
(choice of shielding configurations)
Jacket:• High Quality Audio (HQA) PVC, matte black• Superior flexibility
Applications:• General-purpose audio applications• Home entertainment• Musical instruments
Features:• Twisted conductor construction minimizes
effects of EMI• Precise application of filler maintains
mechanical durability to resist annoyinghandling noise
• Braid shield guards against crosstalk andEMI while minimizing capacitive reactance,which causes hum and buzz
• High strand conductor plus HQA jacketresults in ultimate flexibility
Packaging and Jacket Colors:• Please consult Customer Service for
packaging and color options
Ultra Flexible, Low Impedance 2-Conductor Microphone Cable
CATALOGNUMBER
CONDUCTORINSULATION
& O.D.SHIELD(COV.) JACKET
& O.D.WT.#/M’
IMPEDOHMS
CAPACpF/ft
743701
743704
743705
743706
743707
2/C 24 AWG Stranded105/44 Bare Copper
2/C 24 AWG Stranded41/40 Bare Copper
2/C 24 AWG Stranded16/36 Bare Copper
2/C 22 AWG Stranded26/36 Bare Copper
2/C 20 AWG Stranded41/36 Bare Copper
PVC0.045" Nom.
Polyethylene0.050" Nom.
Polyethylene0.050" Nom.
Polyethylene0.062" Nom.
Polyethylene0.074" Nom.
80% Nom. Bare CopperBraid
95% Tinned Copper Braid
95% Bare Copper Spiral
85% Bare Copper Braid
85% Bare Copper Braid
“HQA” PVC 0.176"Nom. Black
“HQA” PVC 0.194"Nom. Black
“HQA” PVC 0.225"Nom. Black
“HQA” PVC 0.232"Nom. Black
“HQA” PVC 0.262"Nom. Black
22
23
29
34
40
65
80
80
85
80
30
20
20
18
20
137
Electronics Audio/Video & Broadcast Cable
Multi-Conductor, Spiral Shield
Product Construction:Conductor:
• 24 AWG annealed stranded bare copperper ASTM B-3
Insulation:• Premium-grade, coIor-coded PVC• Color Code: See chart below
Shield:• 85% spiral-tinned copper
Jacket:• PVC, black• Temperature range: –20°C to + 90°C
Applications:• Electronic circuits where RF shielding is
required• Radio transmitters• Sound systems• Recording studios• Suggested voltage rating: 300 volts
Features:• Spiral shield provides extra flexibility• Excellent shielding to reduce noise
Packaging:• Please contact Customer Service for
packaging and color options
CATALOGNUMBER
NO. OFCOND.
AWGSIZE
COND.STRAND.
NOM. INSULATIONTHICKNESS
INCHES mm
NOM. JACKETTHICKNESS
INCHES mm
NOMINALO.D.
NOMINAL CAP.*pF/ft
A BINCHES mm
C1226 2 24 105/44 0.012 0.30 0.74 0.176 77.043.04.470.029
Color Code Chart
12
NO. OF CONDUCTORS COLOR
WhiteGreen
*A - Capacitance between conductors*B - Capacitance between one conductor and other conductor connected to shield
138
Audio/Video & Broadcast Cable Electronics
Product Construction:Conductor:
• 24 AWG fully annealed stranded tinnedcopper per ASTM B-33
Insulation:• Premium-grade, coIor-coded polypropylene• Color Code: See chart below
Shield:• Conductive tape applied over the core• 100% Flexfoil® aluminum/polyester,
25% overlap, minimum, foil facing in• Stranded tinned copper drain wire
Jacket:• PVC, black• Temperature range: –20°C to +75°C
Applications:• Electronic circuits where RF shielding is
required• Radio transmitters• Sound systems• Recording studios• Suggested voltage rating: 300 volts
Features:• Excellent shielding to reduce noise
Packaging:• Please contact Customer Service for
packaging and color options
Multi-Conductor, Flexfoil® Shield
CATALOGNUMBER
NO. OFCOND.
AWGSIZE
COND.STRAND.
NOM. INSULATIONTHICKNESS
INCHES mm
NOM. JACKETTHICKNESS
INCHES mm
NOMINALO.D.
NOMINAL CAP.*pF/ft
A BINCHES mm
C1228 2 24 19/36 0.008 0.20 0.51 0.135 48.527.03.430.020
Color Code Chart
12
NO. OF CONDUCTORS COLOR
BlackRed
*A - Capacitance between conductors*B - Capacitance between one conductor and other conductor connected to shield
139
Electronics Audio/Video & Broadcast Cable
12
Product Construction:Conductor:
• 22 AWG fully annealed stranded tinnedcopper per ASTM B-33
Insulation:• Premium-grade, coIor-coded polyethylene• Fillers where required• Color code: See chart below
Shield:• 80% tinned copper braid
Jacket:• PVC, gray• Temperature range: –20°C to + 75°C
Applications:• Low-impedance microphones• Suggested voltage rating: 1000 volts
Features:• Flexlife® jacket provides extreme flexibility• High abrasion resistance• Outstanding appearance
Packaging:• Please contact Customer Service for
packaging and color options
Multi-Conductor, Braid ShieldLow Impedance
Color Code ChartNO. OF
CONDUCTORS COLOR
WhiteBlack
*Capacitance between one conductor and other conductor connected to shield
CATALOGNUMBER TYPE
NO. OFCOND.
AWGSIZE
C1322 LowImped.
2 22
COND.STRAND.
16/34
NOM. INSULATIONTHICKNESS
0.025
INCHES mm
NOM. JACKETTHICKNESS
INCHES mmNOMINAL O.D. NOM. CAP.*
pF/ftINCHES mm
0.64 0.025 0.64 0.239 6.07 31.0
140
Audio/Video & Broadcast Cable Electronics
Product Construction:Conductor:
• 18 and 20 AWG fully annealed strandedtinned copper per ASTM B-33
Insulation:• Premium-grade, coIor-coded rubber
insulation• Color Code: See chart below
Shield:• Clear mylar® wrap• 80% tinned copper braid• Cotton wrap
Jacket:• Rubber, black• Temperature range: –20°C to + 60°C
Applications:C1300, C1301:
• High-impedance microphones• Broadcast and studio use• Communication and audio system• Shielded power supplies• Suggested voltage rating: 300 volts
C1302:• Low-impedance microphones• Studio use• Control circuits• Video and audio interconnecting cables• Shielded power supplies• Suggested voltage rating: 300 volts
Features:• Precision engineered to transmit clear,
noise-free signals• Minimizes electrical “hum”• Braid shield provides extra flexibility
Compliances:• RoHS Compliant Directive 2002/95/EC
Packaging:• Please contact Customer Service for
packaging and color options
Multi-Conductor, Rubber, Braid ShieldHigh and Low Impedance
CATALOGNUMBER
NO. OFCOND.
AWGSIZE
COND.STRAND.
NOM. INSULATIONTHICKNESS
INCHES mm
NOM. JACKETTHICKNESS
INCHES mm
NOMINALO.D. NOMINAL CAP.*
pF/ftINCHES mm
C1300C1301C1302
1
1
2
20
18
20
26/34
41/34
26/34
0.042
0.040
0.020
1.07
1.02
0.51
0.89
0.89
0.89
0.230
0.240
0.270
42.0
46.0
50.0
5.84
6.10
6.86
0.035
0.035
0.035
Color Code Chart
12
NO. OF CONDUCTORS COLOR
WhiteBlack
*Capacitance between one conductor and other conductor connected to shield
141
Electronics Audio/Video & Broadcast Cable
Product Construction:Conductor:
• 18 and 16 AWG fully annealed strandedtinned copper per ASTM B-33
Insulation:• Premium grade color coded rubber• Color Code: See chart below
Shield:• Clear Mylar® wrap• 80% braid tinned copper• Cotton wrap
Jacket:• Carolprene®, black• Temperature range: –20°C to + 60°C
Applications:C1201:
• High-impedance microphones• Broadcast and studio use• Communication and audio systems• Suggested voltage rating: 300 volts
C1202, C1602:• Low-impedance microphones• Studio use• Control circuits• Video and interconnecting cables• Shielded power supplies• Suggested voltage rating: 300 volts
Features:• Precision engineered to transmit clear,
noise-free signals• Minimizes electrical “hum”• Resistant to oil, acid, sunlight, abrasion
and aging• Excellent noise rejection
Compliances:• RoHS Compliant Directive 2002/95/EC
Packaging:• Please contact Customer Service for
packaging and color options
Multi-Conductor, Carolprene®, Braid ShieldHigh and Low Impedance
CATALOGNUMBER
NO. OFCOND.
AWGSIZE
COND.STRAND.
NOM. INSULATIONTHICKNESS
INCHES mm
NOM. JACKETTHICKNESS
INCHES mm
NOMINALO.D. NOMINAL CAP.*
pF/ftINCHES mm
C1201C1202C1602
1
2
2
18
18
16
41/34
41/34
65/34
0.040
0.020
0.025
1.02
0.51
0.64
0.89
0.89
0.89
0.240
0.295
0.335
46.0
61.0
55.0
6.10
7.49
8.51
0.035
0.035
0.035
Color Code Chart
12
NO. OF CONDUCTORS COLOR
WhiteBlack
*Capacitance between one conductor and other conductor connected to shield
142
Audio/Video & Broadcast Cable Electronics
Product Construction:Conductor:
• 24 thru 20 AWG fully annealed strandedtinned copper per ASTM B-33
Insulation:• Premium-grade, coIor-coded polyethylene
(C1333) or PVC (C1345)• Color Code: See chart below
Shield:• 100% Flexfoil® aluminum/polyester foil
with 25% overlap, minimum, foil facing out • Stranded tinned copper drain wire
Jacket:• PVC, gray• Temperature Range: –20°C to + 80°C
Applications:• Audio• Communications• EMI isolated circuits for instrumentation• Suggested voltage rating: 300 volts
Compliances:• UL Style 2093 (UL: 60°C, 300V)• UL Style 2095 (UL: 80°C, 300V)
Packaging:• Please contact Customer Service for
packaging and color options
Special Audio, Communication & InstrumentationUL 2095, 2093
*A-Capacitance between conductors*B-Capacitance between one conductor and other conductors connected to shield
Color Code Chart
Shielded12
Unshielded1
NO. OF COND. COLOR
BlackRed
Natural
*A -Capacitance between conductors*B-Capacitance between one conductor and other conductors connected to shield
Color Code Chart
Shielded1234
Unshielded12
NO. OF COND. COLOR
BlackRedGreenYellow
BlueWhite
CATALOGNUMBER
NO. OFCOND.
AWG SIZE
COND.STRAND.
NOM. INSULATIONTHICKNESS
NOM. JACKETTHICKNESS NOMINAL O.D.
NOM CAP.*pF/ft
INCHES mm INCHES mm INCHES mm A B
C1333 3 2-20Shielded
1-20Unshielded
10/30 0.015 0.38 0.028 0.71 0.206 5.23 26.0 47.0
UL Style 2093, 300 VOLT
CATALOGNUMBER
NO. OFCOND.
AWG SIZE
COND.STRAND.
NOM. INSULATIONTHICKNESS
NOM. JACKETTHICKNESS NOMINAL O.D.
NOM CAP.*pF/ft
INCHES mm INCHES mm INCHES mm A B
C1345 6 4-24Shielded
2-22Unshielded
7/32
7/30
0.015 0.38 0.025 0.64 0.230 5.84 32.0 57.0
UL Style 2095, 300 VOLT
143
Electronics Audio/Video & Broadcast Cable
*A-Capacitance between conductors*B-Capacitance between one conductor and other conductors connected to shield
Color Code Chart
Shielded12
Unshielded12
NO. OF COND. COLOR
BlackRed
GreenWhite
Product Construction:Conductor:
• 22 thru 18 AWG fully annealed strandedtinned copper per ASTM B-33
Insulation:• C1331 - Premium-grade, coIor-coded PVC• C1340 - Premium-grade, coIor-coded
polypropylene• C1343 - Premium-grade, coIor-coded
polyethylene• Color Code: See chart below
Shield:• 100% Flexfoil® aluminum/polyester over
two conductors, 25% overlap, minimum,foil facing out
• Stranded tinned copper drain wire
Jacket:• PVC, gray• Temperature Range: –20°C to + 80°C
Applications:• Audio• Communications• EMI isolated circuits for instrumentation
Compliances:• NEC Article 725 Type CL2
(UL: 75°C, 150V)• C1331 - UL Style 2095 (UL: 80°C, 300V)• C1340 - UL Style 2835 (UL: 60°C, 30V)• C1343 - UL Style 2094 (UL: 60°C, 300V)• Designed to Meet UL 70,000 BTU Vertical
Tray Flame Test
Packaging:• Please contact Customer Service for
packaging and color options
Special Audio, Communication & InstrumentationUL 2095, UL 2835, UL 2094, NEC Type CL2
CATALOGNUMBER
NO. OFCOND.
AWG SIZE
COND.STRAND.
NOM. INSULATIONTHICKNESS
NOM. JACKETTHICKNESS NOMINAL O.D.
NOM CAP.*pF/ft
INCHES mm INCHES mm INCHES mm A B
C1331 4 2-20Shielded
2-20Unshielded
7/28 0.016 0.41 0.032 0.81 0.230 5.84 41 74
UL Style 2095, 300 VOLT, NEC Type CL2
C1340 4 2-22Shielded
2-22Unshielded
7/30 0.008 0.20 0.017 0.43 0.161 4.09 29 52
UL Style 2835, 30 VOLT
C1343 4 2-20Shielded
2-18Unshielded
7/28
16/30
0.018
0.018
0.46
0.46
0.032 0.81 0.259 6.58 27 49
UL Style 2094, 300 VOLT
144
Audio/Video & Broadcast Cable Electronics
Product Construction:Conductor:
• 22 AWG fully annealed stranded tinnedcopper per ASTM B-33
Insulation:• Premium-grade, coIor-coded polyethylene• Color Code: See chart below
Shield:• 64% tinned copper braid over one pair
Jacket:• PVC, gray• Temperature Range: –20°C to +60°C
Applications:• Special audio• Communication and control• Instrumentation• Applications where total isolation of signal
is required• Suggested voltage rating: 300 volts
Compliances:• UL Style 2094 (UL: 60°C, 300V)• Designed to Meet UL VW-1 Vertical Wire
Flame Test
Packaging:• Please contact Customer Service for
packaging and color options
Special Audio, Communication & InstrumentationUL 2094
*A-Capacitance between conductors*B-Capacitance between one conductor and other conductors connected to shield
Color Code Chart
12
NO. OF PAIRS COLOR
Black/NaturalBlack/Natural
CATALOGNUMBER
NO. OFPAIRS
AWG SIZE
COND.STRAND.
NOM. INSULATIONTHICKNESS
NOM. JACKETTHICKNESS NOMINAL O.D.
NOM CAP.*pF/ft
INCHES mm INCHES mm INCHES mm A B
C1338 2 1-22Shielded
1-22 Unshielded
7/30 0.015 0.38 0.030 0.76 0.295 7.49 24 43
145
Electronics Audio/Video & Broadcast Cable
0.177
0.010
0.170
0.006
0.146
0.144
0.013
0.144
0.016
0.144
0.010
0.135
0.006
4.50
0.25
0.432
0.15
3.71
3.66
0.33
3.66
0.41
3.66
0.25
3.43
0.15
CCTV Coaxial, TV Camera & Video SurveillanceUL Type CL2, CATV, CM or CMP; C(UL) Type CM or CMP
C8029RG 6/U Type+18 AWG Unshielded PairUL CL2, CATV, CMC(UL) CM
C8031RG 6/U Type+18 AWG Unshielded PairUL CMPC(UL) CMP
C1103RG 59/U TypeCCTVUL CL2, CATV, CMCSA CMG
1354
C8025RG 59/U Type+22 AWG Shielded PairUL CL2, CATV, CMC(UL) CM
C8027RG 59/U Type+18 AWG Shielded PairUL CL2, CATV, CMC(UL) CM
C8028RG 59/U Type+18 AWG Unshielded PairUL CL2, CATV, CMC(UL) CM
C8030RG 59/U Type+18 AWG Unshielded PairUL CMPC(UL) CMP
Product Construction:Conductors:
•Copper per ASTM B-3•Twisted Pair Color Code: black and red
Insulation/Core:•Cellular polyethylene, FE, or Halar
Shield:•Bare copper or tinned copper or
aluminum braid•Flexfoil® shield available
Jacket:•Premium PVC or Plenum PVC
Packaging:• Please contact Customer Service for
packaging and color options
Applications:• Suitable for RF signal transmission• CATV• DBS• Drop cable• Digital video
CATALOGNUMBER
AWG SIZE
NOM. DCR
INSULATIONMATERIAL
INCHES mm
SHIELD COVERAGE
NOM SHLD DCR
NOMINAL O.D.
NOMINALATTENUATION
VELOCITY OFPROPAGATION,
%
NOMINALIMPEDANCE,
Ω MHz dB/100'
NOMINALCAPACITANCEpF/ft pF/mINCHES mm
18 Ga.Solid BC
Coax
18 AWG 7/26Unshielded Pair
18 AWGSolid BC
Coax
18 AWG 7/26Unshielded Pair
22 Ga.(7X30)Bare
Copper14.8 M
22 AWG7/30 BC
Coax
22 AWG 7/30Shielded Pair
22 AWG7/30 BC
Coax
18 AWG 16/30Shielded Pair
20 AWGSolid BC
Coax
18 AWG 7/26Unshielded Pair
20 AWGSolid BC
Coax
18 AWG 7/26Unshielded Pair
CellularPolyethylene
Premium PVC
CellularFEP
Halar
CellularPolyethylene
CellularPolyethylene
Premium PVC
CellularPolyethylene
Premium PVC
CellularPolyethylene
Premium PVC
CellularFEP
Halar
100% Flexfoil®+95% TinnedCopper Braid
Unshielded Pair
95% Bare CopperBraid
Unshielded Pair
95% BareCopper Braid
2.6 M
95% Bare CopperBraid
25% Overlap Flexfoil®AI/PP Shielded
95% Bare CopperBraid
25% Overlap Flexfoil®AI/PP Shielded
95% Bare CopperBraid
Unshielded Pair
95% Bare CopperBraid
Unshielded Pair
85
86
78
78
78
78
83
75
75
76
76
76
71
75
11050
100200500
1000
11050
100200500
1000
11050
100200500
1000
11050
100200500
1000
11050
100200500
1000
11050
100200500
1000
11050
100200500
1000
0.200.721.482.012.704.466.53
0.300.661.502.103.105.007.30
0.260.912.093.004.337.03
10.64
0.260.912.903.004.337.03
10.64
0.260.912.093.004.337.03
10.64
0.250.781.972.703.976.359.15
0.781.901.982.804.106.829.64
16.20
16.30
17.00
17.00
17.00
16.20
16.30
53.15
53.48
55.78
55.78
55.78
53.15
53.48
Black PVC
Natural PVC
Black PVC
Black PVC
Black PVC
Black PVC
Natural PVC
0.270X
0.493
0.232X
0.416
0.242
0.242X
0.445
0.242X
0.480
0.238X
0.440
0.200X
0.383
6.86X
12.52
5.89X
10.57
6.15
6.147X
11.30
6.15X
12.19
6.05X
11.18
5.08X
9.73
AWM 20006
AWM 20006
AWM 20006
146
Audio/Video & Broadcast Cable Electronics
Direct Burial, Audio & Communication
*A -Capacitance between conductors*B-Capacitance between one conductor and other conductors connected to shield
Color Code Chart
123456789
10
NO. OF COND. COLOR
BlackWhiteRedGreenBrownBlueOrangeYellowVioletGray
CATALOGNUMBER
NO. OFCOND.
AWG SIZE
COND.STRAND.
NOM. INSULATIONTHICKNESS
NOM. JACKETTHICKNESS NOMINAL O.D.
NOM CAP.*pF/ft
INCHES mm INCHES mm INCHES mm A B
C2509C2510C2511
2
3
10
20
20
20
Solid
Solid
Solid
0.013
0.013
0.013
0.33
0.33
0.33
0.037
0.039
0.039
0.94
0.99
0.99
0.190
0.205
0.310
4.83
5.21
7.87
25.0
22.0
20.5
44.0
40.0
37.0
Product Construction:Conductor:
• 20 AWG fully annealed solid tinned copperper ASTM B-33
Insulation:•Premium-grade, coIor-coded polypropylene• Color Code: See chart below
Shield:• 100% Flexfoil® aluminum/polyester
with 25% overlap, minimum, foil facing out• Solid tinned copper drain wire
Jacket:• Permaline® high-density polyethylene,
black• Temperature Range: –20°C to + 80°C
Applications:• Suitable for direct burial• Outdoor uses• 100% shielded cable where RF shielding is
required• Suggested voltage rating: 350 volts
Features:• Permaline® jackets resist deterioration• Sunlight-resistant• Highly durable jacket
Packaging:• Please contact Customer Service for
packaging and color options
147
Electronics Audio/Video & Broadcast Cable
Color Code Chart
123456
NO. OFPAIRS COLORS
Black paired with RedBlack paired with WhiteBlack paired with GreenBlack paired with BlueBlack paired with YellowBlack paired with Brown
Product Construction:Conductor:
• 20 AWG fully annealed stranded tinnedcopper per ASTM B-33
• Twisted pairs
Insulation:• Premium-grade, coIor-coded
polypropylene• Color Code: See chart below
Shield:• 100% Flexfoil® aluminum/polyester
with 25% overlap, minimum, foil facing in• Stranded tinned copper drain wire
each pair• Individually shielded pairs
Jacket:• Permaline® high-density polyethylene,
black• Temperature Range: –20°C to + 80°C
Applications:• Suitable for direct burial• Outdoor uses• Applications where total isolation of signal
is required• Suggested voltage rating: 350 volts
Features:• Permaline® jackets resist deterioration• Sunlight-resistant
Packaging:• Please contact Customer Service for
packaging and color options
Direct Burial, Audio & Communication
CATALOGNUMBER
NO. OFPAIRS
AWG SIZE
COND.STRAND.
NOM. INSULATIONTHICKNESS
NOM. JACKETTHICKNESS NOMINAL O.D.
NOM CAP.*pF/ft
INCHES mm INCHES mm INCHES mm A B
C6061C6062
3
6
20
20
10/30
10/30
0.013
0.013
0.33
0.33
0.047
0.047
1.19
1.19
0.340
0.442
8.64
11.23
22.0
22.0
39.0
39.0 *A -Capacitance between conductors*B-Capacitance between one conductor and other conductors connected to shield
148
Audio/Video & Broadcast Cable Electronics
Product Construction:Conductor:• 24 AWG stranded tinned copper• Twisted pairs
Insulation:• Polyolefin
Shield:• Individually shielded pairs with 24 AWG
drain wire• Overall foil shield 24 AWG drain wire
Jacket:• PVC, matte black• High-flex, flame-retardant
Applications:• Analog audio• Line level microphone• Interconnection and audio components for
console board equipment used in recordingstudios, radio and television stations, andpost-production facilities
• Sound system installations
Features:• PVC jacketing compound for superior
cosmetics, durability and flexibility• Individually shielded and jacketed pairs with
an overall shield• Individual pair jackets alpha numerically
numbered for easy identification
Compliances:• NEC Type CM/CL2
Packaging and Jacket Colors:• Please consult Customer Service for
packaging and color options
Analog Audio Snake Cable70 Ohm Low Capacitance Multi-Pair Individually Shielded & Jacketed
CATALOGNUMBER
CONDUCTORINSULATION
& O.D.SHIELD(COV.) JACKET
& O.D.WT.#/M’
IMPEDOHMS
CAPACpF/ft
740501
740504
740508
740512
740516
740520
740528
740542
740552
1/PR 24 AWG Stranded7/32 Tinned Copper
4/PR 24 AWG Stranded7/32 Tinned Copper
8/PR 24 AWG Stranded7/32 Tinned Copper
12/PR 24 AWG Stranded7/32 Tinned Copper
16/PR 24 AWG Stranded7/32 Tinned Copper
20/PR 24 AWG Stranded7/32 Tinned Copper
28/PR 24 AWG Stranded7/32 Tinned Copper
42/PR 24 AWG Stranded7/32 Tinned Copper
52/PR 24 AWG Stranded7/32 Tinned Copper
Polyolefin0.024" Nom.
Polyolefin0.024" Nom.
Polyolefin0.024" Nom.
Polyolefin0.024" Nom.
Polyolefin0.024" Nom.
Polyolefin0.024" Nom.
Polyolefin0.024" Nom.
Polyolefin0.024" Nom.
Polyolefin0.024" Nom.
Individual Foil 100% w/ 24 AWG Drain
Overall Foil w/ 18 AWG Drain
Individual Foil 100% w/ 24 AWG Drain
Overall Foil w/ 18 AWG Drain
Individual Foil 100% w/ 24 AWG Drain
Overall Foil w/ 18 AWG Drain
Individual Foil 100% w/ 24 AWG Drain
Overall Foil w/ 18 AWG Drain
Individual Foil 100% w/ 24 AWG Drain
Overall Foil w/ 18 AWG Drain
Individual Foil 100% w/ 24 AWG Drain
Overall Foil w/ 18 AWG Drain
Individual Foil 100% w/ 24 AWG Drain
Overall Foil w/ 18 AWG Drain
Individual Foil 100% w/ 24 AWG Drain
Overall Foil w/ 18 AWG Drain
Individual Foil 100% w/ 24 AWG Drain
Overall Foil w/ 18 AWG Drain
FR-PVC MatteFinish 0.137" Nom.
FR-PVC MatteFinish 0.385" Nom.
FR-PVC MatteFinish 0.490" Nom.
FR-PVC MatteFinish 0.610" Nom.
FR-PVC MatteFinish 0.680" Nom.
FR-PVC MatteFinish 0.700" Nom.
FR-PVC MatteFinish 0.820" Nom.
FR-PVC MatteFinish 1.050" Nom.
FR-PVC MatteFinish 1.150" Nom.
11
64
107
160
205
248
340
485
595
65
65
65
65
65
65
65
65
65
24
24
24
24
24
24
24
24
24
NOTE: General Cable manufactures the above cables in a wide range of alternate AWG sizes, pair counts and jacket colors.Please consult Customer Service for details.
149
Electronics Audio/Video & Broadcast Cable
Analog Audio Snake Cable70 Ohm Low Capacitance Multi-Pair Individually Shielded
Product Construction:Conductor:• 24 AWG stranded tinned copper• Twisted pairs
Insulation:• Polyolefin
Shield:• Individually shielded pairs with 24 AWG
drain wire• Overall foil shield 24 AWG drain wire
Jacket:• PVC, matte black• High-flex, flame-retardant
Applications:• Line level microphone• Interconnection and audio components for
console board equipment used in recording studios, radio and television stations, and post-production facilities
• Sound system installations
Features:• PVC jacketing compound for superior
cosmetics, durability and flexibility• Individually shielded pairs are color-coded
for easy identification
Compliances:• NEC Type CM/CL2
Packaging and Jacket Colors:• Please consult Customer Service for
packaging and color options
CATALOGNUMBER
CONDUCTORINSULATION
& O.D.SHIELD(COV.) JACKET
& O.D.WT.#/M’
IMPEDOHMS
CAPACpF/ft
740701
740704
740706
740708
740709
740712
740716
740720
740728
740742
740752
1/PR 24 AWG Stranded7/32 Tinned Copper
4/PR 24 AWG Stranded7/32 Tinned Copper
6/PR 24 AWG Stranded7/32 Tinned Copper
8/PR 24 AWG Stranded7/32 Tinned Copper
9/PR 24 AWG Stranded7/32 Tinned Copper
12/PR 24 AWG Stranded7/32 Tinned Copper
16/PR 24 AWG Stranded7/32 Tinned Copper
20/PR 24 AWG Stranded7/32 Tinned Copper
28/PR 24 AWG Stranded7/32 Tinned Copper
42/PR 24 AWG Stranded7/32 Tinned Copper
52/PR 24 AWG Stranded7/32 Tinned Copper
Polyolefin0.024" Nom.
Polyolefin0.024" Nom.
Polyolefin0.024" Nom.
Polyolefin0.024" Nom.
Polyolefin0.024" Nom.
Polyolefin0.024" Nom.
Polyolefin0.024" Nom.
Polyolefin0.024" Nom.
Polyolefin0.024" Nom.
Polyolefin0.024" Nom.
Polyolefin0.024" Nom.
Individual Foil 100% w/ 24 AWG Drain
Overall Foil w/ 18 AWG Drain
Individual Foil 100% w/ 24 AWG Drain
Overall Foil w/ 18 AWG Drain
Individual Foil 100% w/ 24 AWG Drain
Overall Foil w/ 18 AWG Drain
Individual Foil 100% w/ 24 AWG Drain
Overall Foil w/ 18 AWG Drain
Individual Foil 100% w/ 24 AWG Drain
Overall Foil w/ 18 AWG Drain
Individual Foil 100% w/ 24 AWG Drain
Overall Foil w/ 18 AWG Drain
Individual Foil 100% w/ 24 AWG Drain
Overall Foil w/ 18 AWG Drain
Individual Foil 100% w/ 24 AWG Drain
Overall Foil w/ 18 AWG Drain
Individual Foil 100% w/ 24 AWG Drain
Overall Foil w/ 18 AWG Drain
Individual Foil 100% w/ 24 AWG Drain
Overall Foil w/ 18 AWG Drain
Individual Foil 100% w/ 24 AWG Drain
Overall Foil w/ 18 AWG Drain
FR-PVC MatteFinish 0.137" Nom.
FR-PVC MatteFinish 0.280" Nom.
FR-PVC MatteFinish 0.330" Nom.
FR-PVC MatteFinish 0.350" Nom.
FR-PVC MatteFinish 0.380" Nom.
FR-PVC MatteFinish 0.425" Nom.
FR-PVC MatteFinish 0.490" Nom.
FR-PVC MatteFinish 0.540" Nom.
FR-PVC MatteFinish 0.655" Nom.
FR-PVC MatteFinish 0.775" Nom.
FR-PVC MatteFinish 0.845" Nom.
11
39
55
69
76
96
130
158
221
327
391
65
65
65
65
65
65
65
65
65
65
65
24
24
24
24
24
24
24
24
24
24
24
NOTE: General Cable manufactures the above cables in a wide range of alternate AWG sizes, pair counts and jacket colors.Please consult Customer Service for details.
150
Audio/Video & Broadcast Cable Electronics
Product Construction:Conductor:• 24 AWG stranded tinned copper• Twisted pairs
Insulation:• High-density foamed Polyethylene
Shield:• Individually shielded pairs with 24 AWG
drain wire• Overall foil shield with 18 AWG drain wire
Jacket:• PVC, matte black• High-flex, flame-retardant
Applications:• Digital/audio• Interconnection and audio components for
console board equipment used in recording studios, radio and television stations, and post-production facilities
• Sound system installations
Features:• High impedance, 78% velocity and low
capacitance providing error-freetransmissions over extended distances
• PVC jacketing compound for ultimatecosmetics, durability and flexibility
• Jacketed pairs can be split out of overalljacket for any length without use of heat-shrink tubing
• Individual pair jackets are color-coded andnumber printed for easy identification
Compliances:• NEC Type CM/CL2• Meets/exceeds requirements of Audio
Engineering Society (AES) and EuropeanBroadcast Union (EBU)
Packaging and Jacket Colors:• Please consult Customer Service for
packaging and color options
Digital Audio Snake CableAES/EBU 110 Ohm Multi-Pair Individually Shielded & Jacketed
CATALOGNUMBER
CONDUCTORINSULATION
& O.D.SHIELD(COV.) JACKET
& O.D.WT.#/M’
IMPEDOHMS
CAPACpF/ft
740601
740604
740608
740612
740616
740620
1/PR 24 AWG Stranded7/32 Tinned Copper
4/PR 24 AWG Stranded7/32 Tinned Copper
8/PR 24 AWG Stranded7/32 Tinned Copper
12/PR 24 AWG Stranded7/32 Tinned Copper
16/PR 24 AWG Stranded7/32 Tinned Copper
20/PR 24 AWG Stranded7/32 Tinned Copper
HD-Cellular PE0.066" Nom.
HD-Cellular PE0.066" Nom.
HD-Cellular PE0.066" Nom.
HD-Cellular PE0.066" Nom.
HD-Cellular PE0.066" Nom.
HD-Cellular PE0.066" Nom.
Indiv. Foil w/ 24 AWG DrainOverall Foil w/ 18 AWG Drain
Indiv. Foil w/ 24 AWG DrainOverall Foil w/ 18 AWG Drain
Indiv. Foil w/ 24 AWG DrainOverall Foil w/ 18 AWG Drain
Indiv. Foil w/ 24 AWG DrainOverall Foil w/ 18 AWG Drain
Indiv. Foil w/ 24 AWG DrainOverall Foil w/ 18 AWG Drain
Indiv. Foil w/ 24 AWG DrainOverall Foil w/ 18 AWG Drain
FR-PVC MatteFinish 0.176" Nom.
FR-PVC MatteFinish 0.525" Nom.
FR-PVC MatteFinish 0.700" Nom.
FR-PVC MatteFinish 0.850" Nom.
FR-PVC MatteFinish 1.000" Nom.
FR-PVC MatteFinish 1.100" Nom.
13.5
100
183
250
370
425
110
110
110
110
110
110
12.5
12.5
12.5
12.5
12.5
12.5
NOTE: General Cable manufactures the above cables in a wide range of alternate AWG sizes, pair counts and jacket colors.Please consult Customer Service for details.
151
Electronics Audio/Video & Broadcast Cable
Digital Audio Snake CableAES/EBU 110 Ohm Multi-Pair Individually Shielded
Product Construction:Conductor:• 24 AWG stranded tinned copper• Twisted pairs
Insulation:• High-density foamed Polyethylene
Shield:• Individually shielded pairs with 24 AWG
drain wire
Jacket:• PVC, matte black• High-flex, flame-retardant
Applications:• Console board equipment for recording
studios, radio and television stations, andpost-production facilities
• Sound system installations
Features:• High impedance, 78% velocity and low
capacitance providing error-freetransmissions over extended distances
• PVC jacketing compound for ultimatecosmetics, durability and flexibility
• Individual pair jackets are color-coded andnumber printed for easy identification
Compliances:• NEC Type CM/CL2• Meets/exceeds requirements of Audio
Engineering Society (AES) and EuropeanBroadcast Union (EBU)
Packaging and Jacket Colors:• Please consult Customer Service for
packaging and color options
CATALOGNUMBER
CONDUCTORINSULATION
& O.D.SHIELD(COV.) JACKET
& O.D.WT.#/M’
IMPEDOHMS
CAPACpF/ft
740801
740804
740806
740808
740809
740812
740816
740820
740827
1/PR 24 AWG Stranded7/32 Tinned Copper
4/PR 24 AWG Stranded7/32 Tinned Copper
6/PR 24 AWG Stranded7/32 Tinned Copper
8/PR 24 AWG Stranded7/32 Tinned Copper
9/PR 24 AWG Stranded7/32 Tinned Copper
12/PR 24 AWG Stranded7/32 Tinned Copper
16/PR 24 AWG Stranded7/32 Tinned Copper
20/PR 24 AWG Stranded7/32 Tinned Copper
27/PR 24 AWG Stranded7/32 Tinned Copper
HD-Cellular PE0.066" Nom.
HD-Cellular PE0.066" Nom.
HD-Cellular PE0.066" Nom.
HD-Cellular PE0.066" Nom.
HD-Cellular PE0.066" Nom.
HD-Cellular PE0.066" Nom.
HD-Cellular PE0.066" Nom.
HD-Cellular PE0.066" Nom.
HD-Cellular PE0.066" Nom.
Indiv. Foil w/ 24 AWG DrainOverall Foil w/ 18 AWG Drain
Indiv. Foil w/ 24 AWG DrainOverall Foil w/ 18 AWG Drain
Indiv. Foil w/ 24 AWG DrainOverall Foil w/ 18 AWG Drain
Indiv. Foil w/ 24 AWG DrainOverall Foil w/ 18 AWG Drain
Indiv. Foil w/ 24 AWG DrainOverall Foil w/ 18 AWG Drain
Indiv. Foil w/ 24 AWG DrainOverall Foil w/ 18 AWG Drain
Indiv. Foil w/ 24 AWG DrainOverall Foil w/ 18 AWG Drain
Indiv. Foil w/ 24 AWG DrainOverall Foil w/ 18 AWG Drain
Indiv. Foil w/ 24 AWG DrainOverall Foil w/ 18 AWG Drain
FR-PVC MatteFinish 0.176" Nom.
FR-PVC MatteFinish 0.375" Nom.
FR-PVC MatteFinish 0.447" Nom.
FR-PVC MatteFinish 0.506" Nom.
FR-PVC MatteFinish 0.543" Nom.
FR-PVC MatteFinish 0.610" Nom.
FR-PVC MatteFinish 0.700" Nom.
FR-PVC MatteFinish 0.800" Nom.
FR-PVC MatteFinish 0.895" Nom.
13.5
47
67
91
100
125
168
215
271
110
110
110
110
110
110
110
110
110
12.5
12.5
12.5
12.5
12.5
12.5
12.5
12.5
12.5
NOTE: General Cable manufactures the above cables in a wide range of alternate AWG sizes, pair counts and jacket colors.Please consult Customer Service for details.
152
Audio/Video & Broadcast Cable Electronics
Speaker Wire
Product Construction:Conductor:• 12 - 18 AWG stranded bare copper• Twisted pairs
Insulation:• PVC
Jacket:• PVC, matte black• High flexibility
Applications:• Recording studios• Commercial broadcast facilities
Features:• High durability and long-lasting service
Packaging and Jacket Colors:• Please consult Customer Service for
packaging and color options
CATALOGNUMBER
CONDUCTOR & O.D.INSULATION
& O.D.JACKET& O.D.
WEIGHTLbs/Mft
740002
740102
740202
740302
2/C 12 AWG Stranded65/30 Bare Copper
2/C 14 AWG Stranded41/30 Bare Copper
2/C 16 AWG Stranded26/30 Bare Copper
2/C 18 AWG Stranded41/34 Bare Copper
PVC0.136" Nom.
PVC0.118" Nom.
PVC0.102" Nom.
PVC0.079" Nom.
PVC0.365" Nom.
PVC0.295" Nom.
PVC0.295" Nom.
PVC0.235" Nom.
100
75
60
38
CATALOGNUMBER
CONDUCTOR & O.D.INSULATION
& O.D.JACKET& O.D.
WEIGHTLbs/Mft
740004
740104
740204
740304
4/C 12 AWG Stranded65/30 Bare Copper
4/C 14 AWG Stranded41/30 Bare Copper
4/C 16 AWG Stranded26/30 Bare Copper
4/C 18 AWG Stranded41/34 Bare Copper
PVC0.136" Nom.
PVC0.118" Nom.
PVC0.102" Nom.
PVC0.079" Nom.
PVC0.463" Nom.
PVC0.397" Nom.
PVC0.338" Nom.
PVC0.283" Nom.
165
107
75
53
NOTE: Cabled with jute fillers and paper tape under jacket.
153
Electronics Audio/Video & Broadcast Cable
Product Construction:Conductor:
• 24 thru 12 AWG fully annealed one bare,one tin stranded copper per ASTM B-174
Insulation/Jacket:• Premium-grade PVC• Color Code: See chart below
Applications:• Digital audio• Hi-fi and stereo speaker wire• Lamps• Radios• Juke boxes• Suggested voltage rating: 120 volts• Not for in-wall use
Compliances:• UL Wires Misc. (UL: 120V)
Packaging:• Please contact Customer Service for
packaging and color options
Speaker WireUL Listed (Wires, Misc.) 120V max.
CATALOGNUMBER
NUMBER OFCOND.
C1356C1362C1360C1357C1358C1361C1363
2
2
2
2
2
2
2
AWGSIZE
24
22
20
18
16
14
12
COND.STRAND.
7/32
7/30
10/30
16/30
26/30
41/30
65/30
0.016
0.020
0.020
0.025
0.025
0.025
0.030
0.41
0.51
0.51
0.64
0.64
0.64
0.76
0.058x0.117
0.070x0.145
0.085x0.160
0.083x0.181
0.105x0.210
0.125x0.235
0.154x0.323
NOM. INSULATIONTHICKNESS
1.47x2.79
1.77x3.68
2.16x4.06
2.11x4.60
2.67x5.33
3.18x5.69
3.91x8.20
INCHES mm
NOMINAL O.D.
INCHES mm
Color Code Chart
0102081090
ORDERINGSUFFIX COLORS
BlackWhiteBrownGrayClear
154
Audio/Video & Broadcast Cable Electronics
Product Construction:Conductor:
• 12 AWG fully annealed stranded barecopper conductor per ASTM B-3
Insulation/Jacket:• Premium-grade clear Superflex® PVC• Temperature Range: –20°C to + 60°C• Color Code: See chart below
Applications:• Digital audio• Hi-fi and stereo speaker wire• Lamps• Radios• Juke boxes• Suggested voltage rating: 120 volts• Not for in-wall use
Compliances:• UL Misc. (UL: 120V)
Packaging:• Please contact Customer Service for
packaging and color options
Product Construction:Conductor:
• 18 AWG, 1 tinned and 1 bare copperconductor per ASTM B-174
Insulation:• Premium-grade, clear PVC
Jacket:• PVC, clear• Temperature Range: –20˚C to +60˚C
Applications:• Digital audio• Hi-fi and stereo speaker wire• Lamps• Radios• Juke boxes
Packaging:• Please contact Customer Service for
packaging and color options
Superflex® Speaker Wire
CATALOGNUMBER
NO. OF COND.
C1364 2
AWGSIZE
12
COND.STRAND.
7x37/36 0.060 0.220x
0.456
5.59x
11.58
1.52
NOM. INSULATIONTHICKNESS NOMINAL O.D.
INCHES mm INCHES mm
CATALOGNUMBER
NO. OFCOND.
AWGSIZE
COND.STRAND.
NOM. INSULATIONTHICKNESS
NOM. JACKETTHICKNESS NOMINAL O.D.
INCHES mm INCHES mm INCHES mm
C6367 2 18 16/30 0.016 0.41 0.025 0.64 0.210 5.33
Color Code Chart
90
ORDERINGSUFFIX
STOCK COLOR
Clear
Color Code Chart
90
ORDERINGSUFFIX
STOCK COLOR
Clear
155
Electronics Audio/Video & Broadcast Cable
Command Series® Studio Grade Speaker CableNEC Type CL2
Product Description:Command Series® Studio Grade Speaker Cablebrings sounds to life. It is engineered to deliverthe true fidelity of a music signal from the sourceto the speaker—maintaining the highest signalintegrity for ultimate clarity. It is the perfectspeaker cable for the discriminating audiophile.
Product Construction:Conductor:
• 16 through 12 AWG fully annealed strandedsilver-plated conductor per ASTM B-3
Insulation:• Premium-grade, clear blue PVC• Temperature Range: 0°C to +60°C
Applications:• Digital audio• Stereo systems• In-wall speakers
Features:• Silver-plated conductor lowers electrical
resistance for superior signal rendition• High-strand, rope-lay conductors give the
cable extra flexibility• Convenient footage and polarity markers, at
one foot intervals to make installation easy• Paintable to match any décor
Compliances:• NEC Article 725 Type CL2
CATALOGNUMBER
NO. OFCOND.
AWGSIZE
COND.STRAND. LENGTH
COLOROF
JACKETPACKAGE
TYPE
PKGPER
CARTON
CARTONDIMENSIONS
(H x W x D)
16 AWG CONDUCTORSC1558.15.92 2 16 105/36 250' Clear Blue Spool 1 6.6 x 6.6 x 6.3
CARTONCUBE
0.159
UPC NUMBER
0 79407 76276 7
CARTONWEIGHT
(LBS)
8.5
14 AWG CONDUCTORSC1561.15.92 2 14 168/36 250' Clear Blue Spool 1 6.6 x 6.6 x 6.3 0.159 0 79407 76280 411.5
12 AWG CONDUCTORSC1563.15.92 2 12 259/36 250' Clear Blue Spool 1 13.0 x 6.5 x 9.5 0.464 0 79407 76280 417.5
®
156
Audio/Video & Broadcast Cable Electronics
Command Series® Premium Grade Speaker CableNEC Type CL2
Product Description:Command Series® Premium Grade SpeakerCable was designed to offer outstandingperformance at an affordable price. The cablesare highly flexible and can be used for in-wallinstallations, making them ideal for use in hometheater systems.
The Premium Grade Speaker Cable is availablein 250' spools for custom-cut lengths, and in 25-,50- and 100-foot clamshells. The packagedcables are ideal for display on pegboard,gondolas or H-frame shelves.
Product Construction:Conductor:
• 16 through 12 AWG fully annealed strandedbare copper conductor per ASTM B-3
Insulation:• Premium-grade, clear PVC• Temperature Range: -20°C to +60°C
Applications:• Digital audio• Stereo systems• In-wall speakers
Features:• High-strand, rope-lay conductors give the
cable extra flexibility• Convenient footage and polarity markers, at
one foot intervals to make installation easy• Paintable to match any décor
Compliances:• NEC Article 725 Type CL2
CATALOGNUMBER
NO. OFCOND.
AWGSIZE
COND.STRAND. LENGTH
COLOROF
JACKETPACKAGE
TYPE
PKGPER
CARTON
CARTONDIMENSIONS
(H x W x D)
16 AWG CONDUCTORSC1458.55.90C1458.56.90C1458.57.90C1458.15.90
2
2
2
2
16
16
16
16
105/36
105/36
105/36
105/36
25'
50'
100'
250'
Clear
Clear
Clear
Clear
Coil
Coil
Coil
Spool
6
6
6
1
12.5 x 8.1 x 10.0
12.5 x 8.1 x 10.0
15.5 x 8.1 x 10.0
6.6 x 6.6 x 6.3
CARTONCUBE
0.586
0.586
0.727
0.159
UPC NUMBER
0 79407 76307 8
0 79407 76308 5
0 79407 76309 2
0 79407 76273 6
CARTONWEIGHT
(LBS)
6.4
10.4
18.6
8.5
14 AWG CONDUCTORSC1461.55.90C1461.56.90C1461.57.90C1461.15.90
2
2
2
2
14
14
14
14
105/34
105/34
105/34
105/34
25'
50'
100'
250'
Clear
Clear
Clear
Clear
Coil
Coil
Coil
Spool
6
6
6
1
12.5 x 8.1 x 10.0
12.5 x 8.1 x 10.0
15.5 x 8.1 x 10.0
6.6 x 6.6 x 6.3
0.586
0.586
0.727
0.159
0 79407 76310 8
0 79407 76311 5
0 79407 76312 2
0 79407 76274 3
8.5
14.5
27.0
11.5
12 AWG CONDUCTORSC1463.55.90C1463.56.90C1463.15.90
2
2
2
12
12
12
259/36
259/36
259/36
25'
50'
250'
Clear
Clear
Clear
Coil
Coil
Spool
6
6
1
12.5 x 8.1 x 10.0
15.5 x 8.1 x 10.0
13.0 x 6.5 x 9.5
0.586
0.727
0.464
0 79407 76313 9
0 79407 76314 6
0 79407 76275 0
11.8
21.4
17.5
®
157
Electronics Audio/Video & Broadcast Cable
Command Series® Home Entertainment Speaker CableNEC Type CL3
Product Construction:Conductor:
• 12, 14, 16, or 18 AWG fully annealed,stranded bare copper per ASTM B-8
Insulation:• Premium-grade, coIor-coded polypropylene• Color Code: See chart below
Jacket:• PVC, command blue• Temperature Range: -20˚C to +60˚C
Applications:• Digital audio• Stereo systems• In-wall speakers• Home theater• Remote control circuits• Security systems• Suggested voltage rating: 300 volts• Bi-amp speakers
Features:• Flexible
Compliances:• NEC Article 725 Type CL3 (UL: 60C, 300V)• Designed to meet UL 70,000 BTU Vertical
Tray Flame Test
Packaging:• Please contact Customer Service for
packaging and color options
®
CATALOGNUMBER
NO. OFCOND.
AWGSIZE
COND.STRAND.
NOM. INSULATIONTHICKNESS
NOM. JACKET WALL NOMINAL O.D.
INCHES mm INCHES mm INCHES mm
C1700C1701C1702C1703C1704C1705
2
4
2
4
2
4
12
12
14
14
16
16
65/30
65/30
41/30
41/30
26/30
26/30
0.009
0.009
0.009
0.009
0.009
0.009
0.15
0.15
0.15
0.15
0.15
0.15
0.021
0.021
0.021
0.021
0.021
0.021
0.53
0.53
0.53
0.53
0.53
0.53
0.262
0.308
0.232
0.272
0.198
0.231
6.65
7.82
5.89
6.91
5.03
5.87
Color Code Chart
1234
NO. OF COND. COLOR
BlackRedWhiteGreen
158
Audio/Video & Broadcast Cable Electronics
Product Construction:Conductor:• 20 or 24 AWG stranded bare copper
Insulation:•
Shield:• 36 AWG Bare Copper Braid or Spiral
Jacket:• High Quality Audio (HQA) PVC, matte black• Superior flexibility
Applications:• Guitars• Basses• Keyboards and other instruments to
amplifiers, mixers and effects pedals• All outdoor signal processing gear
Features:• Low capacitance to provide excellent
structural return loss characteristics• Specially formulated vinyl sleeving reduces
triboelectric charges which causemicrophonic handling noise in high-gainamplification applications
Packaging and Jacket Colors:• Please consult Customer Service for
packaging and color options
Guitar/Instrument Cable
CATALOGNUMBER
CONDUCTORINSULATION
& O.D.SHIELD(COV.) JACKET
& O.D.WT.#/M’
IMPEDOHMS
CAPACpF/ft
743601
743602
743603
743604
743605
1/C 20 AWG Stranded41/36 Bare Copper
1/C 20 AWG Stranded41/36 Bare Copper
1/C 20 AWG Stranded41/36 Bare Copper
1/C 20 AWG Stranded22/34 Bare Copper
1/C 24 AWG Stranded7/32 Bare Copper
0.038" Poly0.010" Semi
Conductive Vinyl
0.038" Poly0.010" Semi
Conductive Vinyl
0.038" Poly0.010" Semi
Conductive Vinyl
0.025" Poly0.010" Semi
Conductive Vinyl
0.040" Poly0.010" Semi
Conductive Vinyl
36 AWG 95% Nom. Bare Copper Braid
36 AWG 65% Nom. Bare Copper Spiral
36 AWG 95% Nom. Bare Copper Braid
36 AWG 65% Nom. Bare Copper Spiral
36 AWG 95% Nom. Bare Copper Spiral
“HQA” PVC 0.240Nom. Black
“HQA” PVC 0.240Nom. Black
“HQA” PVC 0.240Nom. Black
“HQA” PVC 0.235Nom. Black
“HQA” PVC 0.235Nom. Black
34
34
34
36
30
47
47
47
47
47
33
33
33
33
33
159
Electronics
Industrial Ethernet Cable 10
Index Page
ToughCAT™ 100E Category 5eUTP Data Cable 160ToughCAT™ 100E Dual Jacket Category 5e UTP Data Cable 161ToughCAT™ 100E ShieldedCategory 5e ScTPData Cable 162ToughCAT™ 100E Dual Shielded Category 5e S/FTPData Cable 163ToughCAT™ 1000 Category 6UTP Data Cable 164ToughCAT™ 1000 Dual Jacket Category 6 UTP Data Cable 165ToughCAT™ 7000 ShieldedCategory 7 (Draft) S/STPData Cable 166
General Cable manufacturesa comprehensive line ofindustrial Ethernet cables.These cables are specificallydesigned to stand up againstthe rigors of the harshenvironments found on thefactory floor and in otherindustrial environments.
The Helix/HiTemp™ Brandindustrial Ethernet cables areavailable in a multitude of riserand plenum constructionssupporting aerial, duct orburied applications, bothindoors and out.
To find the industrialEthernet cable suited for yournext installation, pleasecontact your General Cablesales representative today.
160
Industrial Ethernet Cable Electronics
ToughCAT™ 100E Category 5e UTP Data CableFor Industrial & Harsh Environments / TIA/EIA 4-Pair 24 AWG / Plenum, Riser & Patchcord
Applications• ToughCAT™ 100E horizontal and patch cables
are specifically designed to stand up to therigors of the harsh environments found onthe factory floor and in other industrialenvironments outside the automation island.The cables are constructed with fourbalanced twisted pairs, each consisting of 24AWG insulated conductors
• ToughCAT™ 100E cables support GigabitEthernet, utilizing all four pairs forsimultaneous, bi-direction data transmission(full duplex)
• Four pairs are enclosed with flexible jacketschosen for their adaptability to harshenvironments going beyond those typicallyfound in an office environment. Thesecables are suitable for 10, 100 and 1000Mb/s data rates
Product Construction:Conductor:
• Solid bare 24 AWG copper, except for thepatch, which is stranded 24 AWG tinnedcopper
Insulation:• Plenum-rated versions utilize FEP insulation • Riser-rated and patch versions use
Polyethylene (PE)
Circuit Identification:• Standard orange/blue/green/brown color
code with band marks to identify pairedconductors
Overall Jacket:• Plenum-rated version utilizes UV- and oil-
resistant fluoropolymer jacket that alsoprovides superior abrasion resistance
• Riser-rated version utilizes speciallyformulated UV- and oil-resistant PVC jacket ideal for use in industrial environments
Jacket Marking:• The cable is printed TIA/EIA-568-B.2• Sequential footage marking every two feet
to 1000'
Compliances:• Meets/exceeds TIA/EIA-568-B.2,
ISO/IEC 11801• ETL verified to TIA/EIA-568-B.2• Plenum meets CMP, FT-6• Riser meets CMR, FT-4
Packaging:• Please contact Customer Service for
packaging and color options
CATALOGNUMBER
NUMBEROF PAIRS
CONDUCTORSIZE
CONDUCTOR TYPE RATING CABLE O.D.
INCHES
APPROXIMATE CABLEWEIGHT LBS/MFT
1103308
1003408
1001308
4
4
4
24 AWG
24 AWG
24 AWG
Solid Bare Copper
Solid Bare Copper
Solid Bare Copper
CMP
CMR
CM
.180
.223
.230
22.0
24.5
25.3
Information is subject to change without notice. Consult Customer Service for a variety of alternate constructionsfor specific applications.
DATA TRANSMISSION PERFORMANCE FOR TOUGHCAT™ UTP CAT 5e OUTDOOR CABLES
Frequency
(MHz)
0.77214810162025
31.2562.5100
Insertion Losstypical • max*
(dB/100m)
1.6 • 1.81.9 • 2.03.9 • 4.15.5 • 5.86.2 • 6.57.9 • 8.28.9 • 9.3
10.0 • 10.411.3 • 11.716.3 • 17.021.2 • 22.0
NEXTtypical • min*
(dB)
89.0 • 67.085.0 • 65.379.2 • 56.373.6 • 51.868.4 • 50.366.5 • 47.365.9 • 45.865.0 • 44.361.7 • 42.958.8 • 38.451.7 • 35.3
PSNEXTtypical • min*
(dB)
87.3 • 64.083.1 • 62.375.3 • 53.368.1 • 48.862.2 • 47.358.6 • 44.358.3 • 42.854.9 • 41.350.4 • 39.945.4 • 35.440.2 • 32.3
ACRtypical • min*(dB/100m)
87.4 • 65.283.1 • 63.375.3 • 52.268.1 • 51.062.2 • 43.858.6 • 39.157.0 • 36.555.0 • 33.950.4 • 31.242.5 • 21.430.5 • 13.3
PSACRtypical • min*
(dB/100m)
85.7 • 62.281.2 • 60.371.4 • 49.262.6 • 43.056.0 • 40.850.7 • 36.149.4 • 33.544.9 • 30.939.1 • 28.229.1 • 18.419.0 • 10.3
ELFEXTtypical • min*
(dB/100m)
89.1 • 66.084.9 • 63.874.3 • 51.768.1 • 45.766.5 • 43.862.5 • 39.761.6 • 37.760.4 • 35.857.0 • 33.950.6 • 27.844.9 • 23.8
PSELFEXTtypical • min*
(dB/100m)
82.2 • 63.078.8 • 60.867.8 • 48.761.6 • 42.760.0 • 40.855.8 • 36.753.7 • 34.752.3 • 32.849.7 • 30.943.6 • 24.839.1 • 20.8
RLmin*(dB)
–20.023.024.525.025.025.024.323.621.520.1
*Maximum and minimum performance standards match TIA 568-B.2 standards
161
Electronics Industrial Ethernet Cable
ToughCAT™ 100E Dual Jacket Category 5e UTP Data CableFor Industrial & Harsh Environments / TIA/EIA 4-Pair 24 AWG / Riser
Applications• Dual-jacketed ToughCAT™ 100E horizontal
cable is designed to provide superiorprotection in the harshest environmentsfound on the factory floor and in otherindustrial applications. The cables areconstructed with four balanced twistedpairs, each consisting of 24 AWG insulatedconductors
• ToughCAT™ 100E cables support GigabitEthernet, utilizing all four pairs forsimultaneous, bi-direction data transmission(full duplex)
• Four pairs are enclosed with two flexiblejackets chosen for their adaptability to harshenvironments. These cables are suitable for10, 100 and 1000 Mb/s data rates
Product Construction:Conductors:
• Solid bare 24 AWG copper
Insulation:• Solid Polyethylene (PE) for superior electrical
performance
Circuit Identification:• Standard orange/blue/green/brown color
code with band marks to identify pairedconductors
Dual Jacket:• Inner and outer jackets use a specially
formulated UV- and oil-resistant PVC jacketideal for use in an industrial environment
• Superior abrasion resistance is a hallmark ofthis design
• Paper tape separator between the twojackets facilitates cable prep
Jacket Marking:• The cable is printed TIA/EIA-568-B.2• Sequential footage marking every two feet
to 1000'
Compliances• Meets/exceeds TIA/EIA-568-B.2,
ISO/IEC 11801• ETL verified to TIA/EIA-568-B.2• Riser meets CMR, FT-4
Packaging:• Please contact Customer Service for
packaging and color options
CATALOGNUMBER
NO.OF
PAIRSTYPE CONDUCTOR
SIZECONDUCTOR
TYPERATING
INNER JACKETO.D.
INCHES MM
CABLE O.D.
INCHES MM
APPROXIMATE CABLEWEIGHT
LBS/MFT KG/KM
1004408 Riser 4 Solid Bare Copper24 AWG CMR 0.20 5.1 0.27 6.9 37 55
Information is subject to change without notice. Consult Customer Service for a variety of alternate constructionsfor specific applications.
DATA TRANSMISSION PERFORMANCE FOR TOUGHCAT™ 100E UTP CAT 5e RISERDUAL JACKETED CABLES
Frequency
(MHz)
0.77214810162025
31.2562.5100
Insertion Lossmax*
(dB/100m)
1.82.04.15.86.58.29.310.411.717.022.0
NEXTmin*(dB)
67.065.356.351.850.347.345.844.342.938.435.3
PSNEXTmin*(dB)
64.062.353.348.847.344.342.841.339.935.432.3
ACRmin*
(dB/100m)
65.263.352.251.043.839.136.533.931.221.413.3
PSACRmin*
(dB/100m)
62.260.349.243.040.836.133.530.928.218.410.3
ELFEXTmin*
(dB/100m)
66.063.851.745.743.839.737.735.833.927.823.8
PSELFEXTmin*
(dB/100m)
63.060.848.742.740.836.734.732.830.924.820.8
RLmin*(dB)
–20.023.024.525.025.025.024.323.621.520.1
*Maximum and minimum performance standards match TIA 568-B.2 standards
162
Industrial Ethernet Cable Electronics
ToughCAT™ 100E Shielded Category 5e ScTP Data CableFor Industrial & Harsh Environments / TIA/EIA 4-Pair 24 AWG / Plenum & Riser (26 AWG Patchcord)
Applications• ToughCAT™ 100E ScTP overall foil-shielded
horizontal data cables are specificallydesigned to stand up to the rigors of theharsh environments found on the factory floorand in other industrial environments outsideof the automation island. The foil shieldingsystem with drain wire protects the signalsfrom electromagnetic interference (EMI)
• The cables are constructed with fourbalanced twisted pairs of 24 AWG insulatedconductors (patch cables have 26 AWGconductors)
• ToughCAT™ 100E ScTP cables supportGigabit Ethernet, utilizing all four pairs forsimultaneous, bi-direction data transmission(full duplex)
• Four pairs are enclosed with flexible jacketschosen for their resistance to harshenvironments. These cables are suitable for10, 100 and 1000 Mb/s data rates
Product Construction:Conductors:
• Solid bare 24 AWG copper except for thepatch, which is stranded 26 AWG barecopper
Insulation:• Plenum-rated version utilizes FEP insulation • Riser-rated and patch versions use
Polyethylene (PE)
Circuit Identification:• Standard orange/blue/green/brown color
code with band marks to identify pairedconductors
Shield:• Overall aluminum/Mylar® tape with stranded
tinned copper drain wire
Jacket• Plenum-rated version utilizes a UV- and oil-
resistant fluoropolymer jacket that alsoprovides superior abrasion resistance
• Riser-rated version utilizes a speciallyformulated UV- and oil-resistant PVC jacketideal for use in industrial environments
Jacket Marking:• The cable is printed TIA/EIA-568-B.2• Sequential footage marking every two feet
to 1000'
Compliances• Meets/exceeds TIA/EIA-568-B.2,
ISO/IEC 11801• Plenum meets CMP, FT-6• Riser meets CMR, FT-4
Packaging:• Please contact Customer Service for
packaging and color options
CATALOGNUMBER
NO.OF
PAIRSTYPE CONDUCTOR
SIZECONDUCTOR
TYPERATING
1153408
1053408
1051408
Plenum
Riser
Patch
4
4
4
Solid Bare Copper
Solid Bare Copper
Stranded Bare Copper
24 AWG
24 AWG
24 AWG
CMP
CMR
CM
0.23 5.8
0.27 6.8
0.23 5.8
32 48
32 48
29 42
Information is subject to change without notice. Consult Customer Service for a variety of alternate constructionsfor specific applications.
CABLE O.D.
INCHES MM
APPROXIMATE CABLEWEIGHT
LBS/MFT KG/KM
DATA TRANSMISSION PERFORMANCE FOR TOUGHCAT™ 100E FTP CAT 5e RISERAND PLENUM CABLES
Frequency
(MHz)
0.77214810162025
31.2562.5100
Insertion Lossmax*
(dB/100m)
1.82.04.15.86.58.29.310.411.717.022.0
NEXTmin*(dB)
67.065.356.351.850.347.345.844.342.938.435.3
PSNEXTmin*(dB)
64.062.353.348.847.344.342.841.339.935.432.3
ACRmin*
(dB/100m)
65.263.352.251.043.839.136.533.931.221.413.3
PSACRmin*
(dB/100m)
62.260.349.243.040.836.133.530.928.218.410.3
ELFEXTmin*
(dB/100m)
66.063.851.745.743.839.737.735.833.927.823.8
PSELFEXTmin*
(dB/100m)
63.060.848.742.740.836.734.732.830.924.820.8
RLmin*(dB)
–20.023.024.525.025.025.024.323.621.520.1
*Maximum and minimum performance standards match TIA 568-B.2 standards
DATA TRANSMISSION PERFORMANCE FOR TOUGHCAT™ 100E FTP (ScTP) CAT 5ePATCH CABLES
Frequency
(MHz)
0.77214810162025
31.2562.5100
Insertion Lossmax*
(dB/100m)
2.73.06.28.79.812.314.015.617.625.533.0
NEXTmin*(dB)
67.065.356.351.850.347.345.844.342.938.435.3
PSNEXTmin*(dB)
64.062.353.348.847.344.342.841.339.935.432.3
ACRmin*
(dB/100m)
64.362.350.243.140.635.031.928.725.412.92.3
PSACRmin*
(dB/100m)
61.359.347.240.137.632.028.925.722.49.9-0.7
ELFEXTmin*
(dB/100m)
66.063.851.745.743.839.737.735.833.927.823.8
PSELFEXTmin*
(dB/100m)
63.060.848.742.740.836.734.732.830.924.820.8
RLmin*(dB)
–20.023.024.525.025.025.024.223.320.719.0
*Maximum and minimum performance standards match TIA 568-B.2 standards
163
Electronics Industrial Ethernet Cable
ToughCAT™ 100E Dual Shielded Category 5e S/FTP Data CableFor Industrial & Harsh Environments / EIA/TIA 4-Pair 24 AWG Overall Foil Shield Plus Braid / Riser & Plenum
Applications• ToughCAT™ 100E S/FTP (overall foil and
braid shielded horizontal data cables) arespecifically designed to stand up to therigors of the harsh environments found onthe factory floor and in other industrialenvironments outside of the automationisland. The dual shielding system with drainwire protects the signals from electro-magnetic (EMI) and radio frequencyinterference (RFI)
• Constructed with four balanced twistedpairs, each consisting of 24 AWG insulatedconductors. ToughCAT100E™ S/FTP cablessupport Gigabit Ethernet, utilizing all fourpairs for simultaneous, bi-direction datatransmission (full duplex)
• Four pairs are enclosed with flexiblejacketing chosen for their adaptability toharsh environments. These cables aresuitable for 10, 100 and 1000 Mb/s data rates
Product Construction:Conductors:
• Solid bare 24 AWG copper
Insulation:• Plenum-rated version utilizes FEP insulation• Riser-rated version uses Polyethylene (PE)
Circuit Identification:• Standard orange/blue/green/brown color
code with band marks to identify pairedconductors (specially formulated insulationmakes these colors especially vivid foreasier identification)
Aluminum/Mylar Tape Shield:• Overlapped 25% to maintain 100% coverage
Braid Shield:• Tinned copper braid providing a minimum of
85% coverage. This foil/braid combinationprovides superior protection from radiofrequency (RFI) and electro-magneticinterference (EMI)
Jacket:• Plenum-rated version has a UV- and oil-
resistant fluoropolymer jacket that alsoprovides superior abrasion resistance
• Riser-rated version has a speciallyformulated UV- and oil-resistant PVC jacketideal for use in industrial environmentsoutside of the automation island
Jacket Marking:• The cable is printed TIA/EIA-568-B.2• Sequential footage marking every two feet
to 1000'
Compliances• Meets/exceeds TIA/EIA-568-B.2,
ISO/IEC 11801• Plenum meets CMP, FT-6• Riser meets CMR, FT-4
Packaging:• Please contact Customer Service for
packaging and color options
CATALOGNUMBER TYPE NUMBER
OF PAIRSCONDUCTOR
SIZECONDUCTOR TYPE RATING
1163408 Plenum
1063408 Riser
4
4
24 AWG
24 AWG
Solid Bare Copper
Solid Bare Copper
CMP
CMR
0.22 5.6
0.26 6.6
39 58
39 58
Information is subject to change without notice. Consult Customer Service for a variety of alternate constructionsfor specific applications.
CABLE O.D.
INCHES MM
APPROXIMATE CABLEWEIGHT
LBS/MFT KG/KM
DATA TRANSMISSION PERFORMANCE FOR TOUGHCAT™ 100E S/FTP PLENUM ANDRISER CABLES
Frequency
(MHz)
0.77214810162025
31.2562.5100
Insertion Lossmax*
(dB/100m)
1.82.04.15.86.58.29.310.411.717.022.0
NEXTmin*(dB)
67.065.356.351.850.347.345.844.342.938.435.3
PSNEXTmin*(dB)
64.062.353.348.847.344.342.841.339.935.432.3
ACRmin*
(dB/100m)
65.263.352.251.043.839.136.533.931.221.413.3
PSACRmin*
(dB/100m)
62.260.349.243.040.836.133.530.928.218.410.3
ELFEXTmin*
(dB/100m)
66.063.851.745.743.839.737.735.833.927.823.8
PSELFEXTmin*
(dB/100m)
63.060.848.742.740.836.734.732.830.924.820.8
RLmin*(dB)
–20.023.024.525.025.025.024.323.621.520.1
*Maximum and minimum performance standards match TIA 568-B.2 standards
164
Industrial Ethernet Cable Electronics
ToughCAT™ 1000 Category 6 UTP Data CableFor Industrial & Harsh Environments / TIA/EIA Category 6 UTP 4-Pair 23 AWG Plenum & Riser / 24 AWG Patchcord
Applications• ToughCAT™ 1000 horizontal cables were
developed to support current- and next-generation applications utilizing a 25 MHzbandwidth. They are designed to providesuperior protection in the harshestenvironments found on the factory floor and inother industrial applications
• Typically exhibit 27 dB better PSACR @ 100MHz compared to Category 5erequirements. Lower insertion loss, crosstalkand return loss performance ensures animproved signal-to-noise ratio at the far-end,resulting in cleaner signals, fewer errors andless downtime
• Fully backward compatible with Cat 5ecables/connectors and are perfect forsupporting today’s systems operating at 10Mb/s, 100 Mb/s and 1000 Mb/s, thusallowing future growth
• Four highly balanced pairs are locked inposition by a central spacer to insureperformance and are enclosed with flexiblejackets chosen for their adaptability to harsh environments outside of theautomation island
Production Construction:Conductors:
• 23 AWG solid bare copper (plenum andriser), stranded 24 AWG tinned copperpatchcord
Insulation:• Plenum-rated version utilizes FEP insulation• Riser and patch versions use Polyethylene (PE)
Circuit Identification:• Standard orange/blue/green/brown color
code with band marks to identify pairedconductors
Spacer:• Improves cable electrical performance
Jacket:• Plenum-rated version has a UV- and oil-
resistant fluoropolymer jacket that alsoprovides superior abrasion resistance
• Riser-rated version has a speciallyformulated UV- and oil-resistant PVC jacketideal for use in industrial environmentsoutside of the automation island
Jacket Marking:• The cable is printed TIA/EIA-568-B.2• Sequential footage marking every two feet
to 1000'
Compliances• ETL Verified to meet/exceed TIA/EIA-568-
B.2-1 (Category 6) ISO/IEC 11801• Plenum meets CMP, FT-6• Riser meets CMR, FT-4
Packaging:• Please contact Customer Service for
packaging and color options
CATALOGNUMBER TYPE NUMBER
OF PAIRSCONDUCTOR
SIZECONDUCTOR TYPE RATING
1105508 Plenum
1005508 Riser
1005708 Patch
4
4
4
23 AWG
23 AWG
24 AWG
Solid Bare Copper
Solid Bare Copper
Stranded Tinned Copper
CMP
CMR
CM
0.22 5.6
0.24 6.1
0.23 5.8
31 46
33 49
28 42
Information is subject to change without notice. Consult Customer Service for a variety of alternate constructionsfor specific applications.
CABLE O.D.
INCHES MM
APPROXIMATE CABLEWEIGHT
LBS/MFT KG/KM
DATA TRANSMISSION PERFORMANCE FOR TOUGHCAT™ 1000 UTP CAT 6 PLENUMAND RISER CABLES
Frequency
(MHz)
0.77214810162025
31.2562.5100155200250
Insertion Lossmax*
(dB/100m)
1.82.03.85.36.07.68.59.510.715.419.825.229.032.8
NEXTmin*(dB)
76.074.365.360.859.356.354.853.351.947.444.341.539.838.3
PSNEXTmin*(dB)
74.072.363.358.857.354.352.851.349.945.442.339.537.836.3
ACRmin*
(dB/100m)
74.272.361.555.553.348.746.343.841.232.024.516.310.85.5
PSACRmin*
(dB/100m)
72.270.359.553.551.346.744.341.839.230.022.514.38.83.5
ELFEXTmin*
(dB/100m)
70.067.855.749.747.843.741.739.837.931.827.823.921.719.8
PSELFEXTmin*
(dB/100m)
67.064.852.746.744.840.738.736.834.928.824.820.918.716.8
RLmin*(dB)
–20.023.024.525.025.025.024.323.621.520.118.818.017.3
*Maximum and minimum performance standards match TIA 568-B.2 standards
DATA TRANSMISSION PERFORMANCE FOR TOUGHCAT™ 1000 UTP CAT 6 PATCH CABLES
Frequency
(MHz)
0.77214810162025
31.2562.5100155200250
Insertion Lossmax*
(dB/100m)
2.22.44.66.47.29.110.211.412.818.523.830.234.839.4
NEXTmin*(dB)
76.074.365.360.859.356.354.853.351.947.444.341.539.838.3
PSNEXTmin*(dB)
74.072.363.358.857.354.352.851.349.945.442.339.537.836.3
ACRmin*
(dB/100m)
73.871.960.754.452.147.144.641.939.128.920.611.25.0-1.0
PSACRmin*
(dB/100m)
71.869.958.752.450.145.142.639.937.126.918.69.23.0-3.0
ELFEXTmin*
(dB/100m)
70.067.855.749.747.843.741.739.837.931.827.823.921.719.8
PSELFEXTmin*
(dB/100m)
67.064.852.746.744.840.738.736.834.928.824.820.918.716.8
RLmin*(dB)
–20.023.024.525.025.025.024.223.320.719.017.416.415.6
*Maximum and minimum performance standards match TIA 568-B.2 standards
165
Electronics Industrial Ethernet Cable
ToughCAT™ 1000 Dual Jacket Category 6 UTP Data CableFor Industrial & Harsh Environments / TIA/EIA Category 6 UTP 4-Pair 23 AWG / Riser-Rated
Applications• This dual jacketed ToughCAT™ 1000
horizontal cable, developed to supportcurrent and next-generation applicationsutilizing 250 MHz bandwidth, is designed toprovide superior protection in the harshestenvironments found on the factory floor andin other industrial environments outside theautomation island
• Typically exhibit 27 dB better PSACR @ 1000MHz compared to Category 5e requirements.Lower insertion loss, crosstalk and return lossperformance ensures an improved SNR at thefar-end, resulting in cleaner signals, fewererrors and less downtime
• Fully backward compatible with Cat 5ecables and connectors and are perfect forsupporting today’s systems operating at 10Mb/s, 100 Mb/s and 1000 Mb/s, thusallowing future growth
• Four highly balanced pairs are locked inposition by a central spacer, to insureperformance and are enclosed with twoflexible jackets chosen for their adaptabilityto harsh environments going beyond thosetypically found in an office environment
Product Construction:Conductors:
• 23 AWG solid bare copper
Insulation:• Solid Polyethylene (PE) for superior electrical
performance
Circuit Identification:• Standard orange/blue/green/brown color
code with band marks to identify pairedconductors
Spacer:• Improves cable electrical performance
Dual Jackets:• Inner and outer jackets use a specially
formulated UV- and oil-resistant PVC jacketideal for use in an industrial environmentoutside of the automation island
Jacket Marking:• The cable is printed TIA/EIA-568-B.2• Sequential footage marking every two feet
to 1000'
Compliances• Riser meets CMR, FT-4
Packaging:• Please contact Customer Service for
packaging and color options
CATALOGNUMBER
TYPE NO.OF
PAIRS
CONDUCTORSIZE
CONDUCTORTYPE
RATING
1015508 Riser 4 Solid Bare Copper23 AWG CMR 0.25 6.4 0.32 8.1 46 69
Information is subject to change without notice. Consult Customer Service for a variety of alternate constructionsfor specific applications.
INNER JACKETO.D.
INCHES MM
CABLE O.D.
INCHES MM
APPROXIMATE CABLEWEIGHT
LBS/MFT KG/KM
DATA TRANSMISSION PERFORMANCE FOR TOUGHCAT™ 1000 UTP CAT 6 PLENUMAND RISER CABLES
Frequency
(MHz)
0.77214810162025
31.2562.5100155200250
Insertion Losstypical • max*
(dB/100m)
1.5 • 1.81.7 • 2.03.4 • 3.84.9 • 5.35.5 • 6.07.0 • 7.67.9 • 8.59.0 • 9.5
10.1 • 10.714.7 • 15.419.0 • 19.824.1 • 25.227.8 • 29.031.4 • 32.8
NEXTtypical • min*
(dB)
97.7 • 76.094.5 • 74.386.1 • 65.380.9 • 60.876.2 • 59.375.5 • 56.374.7 • 54.874.0 • 53.372.8 • 51.968.1 • 47.462.6 • 44.361.0 • 41.558.5 • 39.858.0 • 38.3
PSNEXTtypical • min*
(dB)
91.5 • 74.088.5 • 72.378.3 • 63.373.6 • 58.870.7 • 57.369.1 • 54.368.4 • 52.864.5 • 51.363.0 • 49.962.2 • 45.455.4 • 42.353.1 • 39.550.9 • 37.849.7 • 36.3
ACRtypical • min*(dB/100m)
96.2 • 74.292.8 • 72.382.7 • 61.576.0 • 55.570.7 • 53.368.5 • 48.766.8 • 46.365.0 • 43.862.7 • 41.253.4 • 32.043.6 • 24.536.9 • 16.330.7 • 10.826.6 • 5.5
PSACRtypical • min*
(dB/100m)
90.0 • 72.286.8 • 70.374.9 • 59.568.7 • 53.565.2 • 51.362.1 • 46.760.5 • 44.355.5 • 41.852.9 • 39.247.5 • 30.036.4 • 22.529.0 • 14.323.1 • 8.818.3 • 3.5
ELFEXTtypical • min*
(dB/100m)
87.8 • 70.081.6 • 67.876.8 • 55.773.0 • 49.770.0 • 47.866.0 • 43.764.8 • 41.763.9 • 39.861.9 • 37.955.2 • 31.851.6 • 27.848.4 • 23.946.4 • 21.745.5 • 19.8
PSELFEXTtypical • min*
(dB/100m)
81.3 • 67.080.8 • 64.869.1 • 52.763.5 • 46.761.5 • 44.857.9 • 40.756.0 • 38.754.7 • 36.852.6 • 34.947.8 • 28.844.9 • 24.842.0 • 20.939.5 • 18.737.9 • 16.8
RLmin*(dB)
–20.023.024.525.025.025.024.323.621.520.118.818.017.3
*Maximum and minimum performance standards match TIA 568-B.2 standards
166
Industrial Ethernet Cable Electronics
ToughCAT™ 7000 Shielded Category 7 (Draft) S/STP Data CableFor Industrial & Harsh Environments / TIA/EIA 4-Pair 22 AWG / Plenum & Riser
Applications• ToughCAT™ 7000 is a Category 7, four-pair
shielded twisted pair data cable with anextremely high bandwidth of 600 MHz, farexceeding the bandwidths of Category 5e and 6
• Fully backward compatible with Cat 5e andCat 6 and is recommended for installationswhere very high bit rates (2.4 Gb/s or more)and/or a very high degree of shielding isrequired
• Constructed with four highly balanced pairs.Each pair is individually shielded and cabledtogether to form the cable core. The cablecore is covered with a tin copper braid and athermoplastic jacket. A drain wire is includedto enable easy shield termination
• Available in plenum and non-plenum versionsand a great variety of jacket colors
Product Construction:Conductors:
• Solid bare 22 AWG copper
Insulation:• Plenum-rated version utilizes FEP insulation• Riser-rated version utilizes Polyethylene (PE)
Circuit Identification:• Standard orange/blue/green/brown color
code with band marks to identify pairedconductors
Aluminum/Mylar® Tape Shield:• Individual pairs are aluminum foil/tape
shielded; tinned copper braid and a 24 AWGdrain wire is used over the cabled pairs
Braid Shield:• Tinned copper braid with a drain wire
providing a minimum of 85% coverageincreases the ability of these cables toeffectively guard against EMI and RFI
Jacket:• Plenum-rated version has a UV- and oil-
resistant fluoropolymer jacket that alsoprovides superior abrasion resistance
• Riser-rated version has a speciallyformulated UV- and oil-resistant PVC jacketideal for use in industrial environmentsoutside of the automation island
Jacket Marking:• The cable is printed TIA/EIA-568-B.2• Sequential footage marking every two feet
to 1000'
Compliances• Meets/exceeds draft requirements of IEC
11801 for 600 MHz Category 7• Exceeds TIA/EIA-568 requirements
(Category 5e and 6)• Plenum meets CMP, FT-6• Riser meets CMR, FT-4
Packaging:• Please contact Customer Service for
packaging and color options
CATALOGNUMBER TYPE NUMBER
OF PAIRSCONDUCTOR
SIZECONDUCTOR TYPE RATING
1106508 Plenum
1006508 Riser
4
4
22 AWG
22 AWG
Solid Bare Copper
Solid Bare Copper
CMP
CMR
0.32 8.1
0.32 8.1
60 89
54 80
Information is subject to change without notice. Consult Customer Service for a variety of alternate constructionsfor specific applications.
CABLE O.D.
INCHES MM
APPROXIMATE CABLEWEIGHT
LBS/MFT KG/KM
DATA TRANSMISSION PERFORMANCE FOR TOUGHCAT™ 7000 SHIELDED (S/STP) CAT 7PLENUM AND RISER CABLESFrequency
(MHz)
0.77214810162025
31.2562.577.580100125130150
155.52160165175200230250255300310350360400550600
Attenuationmax
(dB/100m)
1.82.03.75.25.97.48.39.310.414.916.616.919.021.421.823.624.024.424.825.627.529.631.031.334.234.837.237.840.047.750.1
NEXTmin(dB)
78.078.078.078.078.078.078.078.078.075.574.173.972.470.970.769.869.569.369.168.867.967.066.466.365.265.064.264.163.461.360.7
PSNEXTmin(dB)
75.075.075.075.075.075.075.075.075.072.571.170.969.467.967.766.866.566.366.165.864.964.063.463.362.262.061.261.160.458.357.7
PROP. DELAYmax
(dB/100m)
575.0570.0552.0546.7545.4543.0542.0541.2540.4538.6538.1538.0537.6537.2537.2536.9536.9536.8536.8536.7536.5536.4536.3536.3536.1536.0535.9535.9535.8535.5535.5
ELFEXTmin
(dB/100m)
–83.071.064.963.058.957.055.053.147.145.244.943.041.140.739.539.238.938.738.137.035.835.034.933.533.232.131.931.028.227.4
PSELFEXTmin
(dB/100m)
–80.068.061.960.055.954.052.050.144.142.241.940.038.137.736.536.235.935.735.134.032.832.031.930.530.229.128.928.025.224.4
RLmin
(dB/100m)
19.420.023.024.525.025.025.024.323.621.520.920.820.119.419.318.918.818.718.618.418.017.617.317.316.816.716.316.215.914.914.7
167
Electronics
Specialty Cable 11
Index Page
SmartWrap™ Bundled Cable 168Fluorobus Cable 169Fire Wire 170Computer Cable 171General Cable has a variety
of Helix/HiTemp™ Brand wireand cable available for specialapplications. This sectionincludes an array of productsfrom our SmartWrap™ bundledcable and Fluorobus flat busground/power distributioncable to high-speed serialinterface cable, known as FireWire, and computer cables.
For more information onthese cables or for otherspecial applications, pleasecontact your General Cablesales representative.
168
Specialty Cable Electronics
SmartWrap™ Bundled CableMultiple Cable Types Depending On Application Up to 6 Cables / Jacketed and Unjacketed
Applications:SmartWrap™ cables are several differentcables available with either helical binding oroverall jacketing to allow simultaneouspulling of multiple cables. Configurationsinclude combinations of Cat 5e UTP orScTP, RG6 video/data quad shield coax andoptical fiber cables. Plenum and riserversions available
Product ConstructionFiber:• Multimode or singlemode fibers with easily
strippable 900µm tight buffering colored perTIA/EIA 598
• Cabled with aramid yarn strength memberand jacketed to meet appropriate standards
Coax:• Quad shield RG6 coax with copper-clad
steel center conductor, either foamed PE(riser) or FEP (plenum) dielectric and overallPVC jacket
Twisted Pair:• Unshielded or shielded twisted pair that
meets or exceeds all 568B.2 standards forCategory 5e SuperCat 100E
Binder:• Helically wound polyester binder
Overall Jacket (Optional):• Riser-rated versions use a flame-
retardant PVC
Features:• Many cables can be pulled at once—faster
installation• TIA/EIA 568B.2 Crosstalk-compliant• Simplifies cable management• Excellent for residential applications
Compliances:• CMR, CSA FT-4 riser• CMP, CSA FT-6 plenum
Packaging:• Please contact Customer Service for
packaging and color options
CATALOGNUMBER
SAFETY RATINGBINDING OR
JACKET CONSTRUCTION
710021
810021
710022
810022
710023
810023
710024
810024
710010
710011
710017
710018
Riser
Plenum
Riser
Plenum
Riser
Plenum
Riser
Plenum
Riser
Plenum
Riser
Plenum
Binding
Binding
Binding
Binding
Binding
Binding
Binding
Binding
Jacket
Jacket
Binding
Binding
4 SuperCat™ 100E Cat 5e UTP
4 SuperCat™ 100E Cat 5e UTP
6 SuperCat™ 100E Cat 5e UTP
6 SuperCat™ 100E Cat 5e UTP
4 SuperCat™ 100E Cat 5e ScTP
4 SuperCat™ 100E Cat 5e ScTP
6 SuperCat™ 100E Cat 5e ScTP
6 SuperCat™ 100E Cat 5e ScTP
2 SuperCat™ 100E Cat 5e UTP and 2 RG6 Quad Smart Home coax
2 SuperCat™ 100E Cat 5e UTP, 2 RG6 Quad Smart Home coax and 2 simplex multimode fiber cables
2 SuperCat™ 100E Cat 5e UTP and 2 RG6 Quad Smart Home coax
2 SuperCat™ 100E Cat 5e UTP, 2 RG6 Quad Smart Home coax and 2 sim-plex multimode fiber cables
Frequency(MHz)
Insertion Loss typical • max*
(dB/100m)
NEXT typical • min*
(dB)
PSNEXT typical • min*
(dB)
ACRtypical • min*
(dB/100m)
PSACR typical • min*
(dB/100m)
ELFEXT typical • min*
(dB/100m)
PSELFEXT typical • min*
(dB/100m)
ReturnLoss min
(dB)
1 19.3 • 22.0 51.9 • 35.3 43.8 • 32.3 32.6 • 13.3 24.5 • 10.3 43.7 • 23.8 38.8 • 20.8 20.1
DATA TRANSMISSION PERFORMANCE FOR CAT 5E CABLES
DC Resistance 9.38 r/Ohms / 100 Meters • 28.6 Ohms /1000 Feet Input Impedance 100 r/Ohms ± 15% @ 1 - 100 MHz
DCR Unbalanced 5% Propagation Delay (Skew) 45 nanoseconds/100 meters max
Mutual Capacitance 55.8 pF/m • 17 pF/ft Velocity of Propagation 72% plenum / 69% riser
ELECTRICAL CHARACTERISTICS FOR CAT 5E CABLES
Capacitance 53.2 pF/m • 16.2 pF/ft Attenuation (dB/100 ft) 0.21@ 1 MHz • 6.04 dB @ 1000MHz
Characteristic Impedance 75 r/Ohms Velocity of Propagation 83% riser
ELECTRICAL CHARACTERISTICS FOR RG6 CABLES
The above listings are for stock cables. Custom configurations are available. Information is subject to change without notice.Consult Customer Service for a variety of alternate constructions for specific applications.
NOTE: max/min measurements match TIA/EIA 568B-2 standards
169
Electronics Specialty Cable
Fluorobus CableFlat Bus Ground / Power Distribution Cable
Applications:Ideally suited for low-voltage primary andsecondary power distribution in electronicand data processing equipment. High-speed, solid- state circuits require relativelyhigh currents with low voltage. For thisreason, it is essential that DC powerdistribution lines have low inductance, lowresistance and high capacitance. Moreimportant, tightly bundled or laminated flatcable source-and-return circuits deliverlower impedance and higher capacitance byone to two orders of magnitude, comparedto round wire circuits with equal resistance.
This system can serve as a low-cost flexiblealternative to laminated bus bars. TheFluorobus low-profile routing capability is auseful packaging feature and its largesurface area (relative to round wireconductor of equal resistance) providesimproved heat dissipation, minimizes voltagedrop and results in a higher current rating.
This flat conductor circuit delivers superiorEMI/RFI performance, both as a source andas a receiver.
Features Benefits
Low Profile: Conserves space
Flexible: Ease of routing
Large Surface Area: Improved heat dissipationminimizes voltage drophigh current rating
Temperature Rating:• -50°C to +150°C
Voltage Rating:• 300 Volts and 600 Volts (AWM) available
(Consult Customer Service)
Dielectric Constant:• 2.6
Dielectric Strength:• 900 VRMS
Packaging and Color:• Please consult Customer Service for
packaging and color options
CATALOGNUMBER CONDUCTOR INSULATION FINISHED
DIMENSIONS DCR POWER RATING
SP00C0011010
SP00C0012010
Flat Solid BC0.010" x 0.987"
Flat Solid BC0.020" x 0.987"
Tefzel®(ETFE)
Tefzel®(ETFE)
0.028 x 1.022
0.037 x 1.022
0.82 Ohms per1000 ft. @ 25˚C
0.41 Ohms per1000 ft. @ 25˚C
32 Amps Nom.100 Amps Max.
64 Amps Nom.100 Amps Max.
Information is subject to change without notice.
170
Specialty Cable Electronics
Applications:• Transport digital data for computers and for
professional and consumer electronicproducts
• Personal computers• Audio/image/video products• Printers/scanners• Disc arrays• Digital video cameras/displays/recorders
Compliances:• UL: AWM 20276• 80˚C 30V VW-1• CSA: PCC FT1
Packaging and Jacket Colors:• Please consult Customer Service for
packaging and color options
Fire WireIEEE 1394 High-Speed Serial Interface
CATALOGNUMBER
POWER CONDUCTORSIGNAL PAIRS OVERALL
SHIELDINGOVERALLJACKET
SIGNAL PR.IMPED.
SIGNAL PR.CAPAC
Nom.MHz
ATTENUATION
DB 100'
Z028C0061110
2/C #227/36 TC
Foam Poly InsulationIndividual Foil & Braid
No. 1: Red, GreenNo. 2: Blue Orange
2/C #227/36 TC
PolyolefinInsulation
Black, White
Flexible PVCAluminum/Mylar®
(Foil Out)+ 95% Braid
110 Ohms 12.5 pF/ft 1000.0 37 55
* Apple Computer Trademark
171
Electronics Specialty Cable
PART NUMBER APPLICATION DESCRIPTION
Computer CableMainframes, Data Transfer, Tape Drives, File Servers, Disc Drives, Workstations, Disc Arrays, Personal Computers, etc.
Applications:General Cable manufactures adiverse array of multiconductorcables for computers and the inter-connection of their peripherals.Today’s need for speed and signalcapacity demands the most incable materials and construction.Our state-of-the-art manufacturingallows us to control impedance,minimize signal skew and providethe proper shielding for applicationsfrom SCSI, USB and Fire Wire rightup through the latest Fiber Channelprotocols. Whether your applica-tions require parallel or serial signaltransmission, General Cable hasthe technology to fill your needs.
Packaging and Jacket Colors:• Please consult Customer Service for
packaging and color options
PART NUMBER APPLICATION DESCRIPTION
PART NUMBER APPLICATION DESCRIPTION
PART NUMBER APPLICATION DESCRIPTION
172
Electronics
CSA Approved Cable 12
Index Page
Multi-Conductor, Unshielded 173-175
Multi-Conductor, Foil Shield 176-177
Multi-Paired, Foil Shield 178-179
Multi-Conductor, Foil Shield 180
Multi-Paired, Individually Shielded 181
General Cable offers avariety of cost-effectiveCanadian electronic wire andcable products includingsound, security, alarm,instrumentation and control,broadcast, shielded andunshielded cables.
These products arespecifically designed forCanadian applications andmeet or exceed CSACertification requirements.
For more information on ourline of CSA Certified cables orfor other special applications,please contact your GeneralCable sales representative.
173
Electronics CSA Approved Cable
Product Construction:Conductor:• 22 AWG fully annealed, stranded tinned
copper per ASTM B-33
Insulation:• Premium-grade, coIor-coded PVC • Color Code: See charts below
Jacket:• PVC, gray• Temperature Range: –20°C to + 105°C
Applications:• Public address systems• Intercoms• Internal telephones• Remote control circuits• Suitable for EIA RS-232 applications• Suggested voltage rating: 300 or 600 volts
Features:• Easy to terminate• Excellent electrical properties• Tinned conductors provide excellent
corrosion resistance• Assists soldering applications
Compliances:• AWM Style 2464 (CSA: 80˚C, 300V)• CSA Type AWM (105˚C, 600V)• CSA Certified CMG to harmonized standard
UL444 and CSA 22.2 No. 214• NEC/CEC Type CMG (CSA: 105˚C, 300V)• Designed to Meet CSA 70,000 BTU Vertical
Tray Flame Test• Passes CSA FT4 vertical flame test
Packaging:• Please contact Customer Service for
packaging and color options
Multi-Conductor, UnshieldedAWM Style 2464, CSA Type AWM, NEC/CEC Type CMG (CSA C/US)
CATALOGNUMBER
NO. OFCOND.
AWGSIZE
COND.STRAND.
NOM. INSULATIONTHICKNESS
INCHES
C4100
C4101
C4102C4103C4104C4105C4106C4107C4108C4109C4110C4111C4112C4113C4114C4115C4116
2
3
456789
101215182025304050
22
22
222222222222222222222222222222
7/30
7/30
7/307/307/307/307/307/307/307/307/307/307/307/307/307/307/30
mm
0.010
0.010
0.0100.0100.0100.0100.0100.0100.0100.0100.0100.0100.0100.0100.0100.0100.010
0.25
0.25
0.250.250.250.250.250.250.250.250.250.250.250.250.250.250.25
NOM. JACKETTHICKNESS
INCHES mm
0.032
0.032
0.0320.0320.0320.0320.0320.0320.0320.0320.0320.0320.0320.0320.0320.0320.032
0.81
0.81
0.810.810.810.810.810.810.810.810.810.810.810.810.810.810.81
NOMINAL O.D.
NOM.C-C
CAP.*pF/ftINCHES mm
0.150
0.176
0.1890.2030.2080.2180.2340.2490.2680.2760.3030.3180.3340.3680.3890.4340.489
3.81
4.47
4.805.16 5.285.545.946.326.817.017.708.08 8.48 9.359.88
11.0212.42
COLORCODE
Black/Red
Black/Red/
Green111111 11222 2222
27.5
27.5
27.5 27.5 27.5 27.5 27.5 27.5 27.5 27.5 27.5 27.5 27.5 27.5 27.5 27.5 27.5
*Capacitance between conductors
Color Code Chart 2 Per ICEA - For cables of 15 thru 50 conductors
123456789
1011121314151617
NO. OFCOND. COLOR
BlackWhiteRedGreenOrangeBlueWhite/BlackRed/BlackGreen/BlackOrange/BlackBlue/BlackBlack/WhiteRed/WhiteGreen/WhiteBlue/WhiteBlack/RedWhite/Red
1819202122232425262728293031323334
NO. OFCOND. COLOR
Orange/RedBlue/RedRed/GreenOrange/GreenBlack/White/RedWhite/Black/RedRed/Black/WhiteGreen/Black/WhiteOrange/Black/WhiteBlue/Black/WhiteBlack/Red/GreenWhite/Red/GreenRed/Black/GreenGreen/Black/OrangeOrange/Black/GreenBlue/White/OrangeBlack/White/Orange
35363738394041424344454647484950
NO. OFCOND. COLOR
White/Red/OrangeOrange/White/BlueWhite/Red/BlueBlack/White/GreenWhite/Black/GreenRed/White/GreenGreen/White/BlueOrange/Red/GreenBlue/Red/GreenBlack/White/BlueWhite/Black/BlueRed/White/BlueGreen/Orange/RedOrange/Red/BlueBlue/Red/OrangeBlack/Orange/Red
Color Code Chart 1 - For cables up to and including 12 conductors
123456
NO. OFCOND. COLOR
BlackWhiteRedGreenBrownBlue
789
101112
NO. OFCOND. COLOR
OrangeYellowVioletGrayPinkTan
174
CSA Approved Cable Electronics
Multi-Conductor, UnshieldedAWM Style 2464, CSA Type AWM, NEC/CEC Type CMG (CSA C/US)
CATALOGNUMBER
NO. OFCOND.
AWGSIZE
COND.STRAND.
NOM. INSULATIONTHICKNESS
INCHES
C4117
C4118 C4119 C4120 C4121 C4122 C4123 C4124 C4125
C4214 C4126 C4127 C4128 C4206 C4129 C4130 C4131 C4132 C4133 C4134
2
3
4
5
7
9
12
15
2
2
3
4
5
6
7
9
12
15
19
25
20
20
20
20
20
20
20
20
18
18
18
18
18
18
18
18
18
18
18
18
7/28
7/28
7/28
7/28
7/28
7/28
7/28
7/28
16/30
16/30
16/30
16/30
16/30
16/30
16/30
16/30
16/30
16/30
16/30
16/30
mm
0.016
0.016
0.016
0.016
0.016
0.016
0.016
0.016
0.016
0.016
0.016
0.016
0.016
0.016
0.016
0.016
0.016
0.016
0.016
0.016
0.41
0.41
0.41
0.41
0.41
0.41
0.41
0.41
0.41
0.41
0.41
0.41
0.41
0.41
0.41
0.41
0.41
0.41
0.41
0.41
NOM. JACKETTHICKNESS
INCHES mm
0.025
0.032
0.032
0.032
0.032
0.032
0.032
0.032
0.032
0.032
0.032
0.032
0.032
0.032
0.032
0.032
0.032
0.032
0.032
0.032
0.64
0.81
0.81
0.81
0.81
0.81
0.81
0.81
0.81
0.81
0.81
0.81
0.81
0.81
0.81
0.81
0.81
0.81
0.81
0.81
NOMINAL O.D.
NOM.C-C
CAP.*pF/ftINCHES mm
0.192
0.216
0.235
0.254
0.275
0.317
0.354
0.392
0.210
0.210
0.236
0.258
0.280
0.304
0.309
0.358
0.401
0.445
0.469
0.549
4.88
5.49
5.97
6.45
6.99
8.05
8.99
9.96
5.33
5.33
5.99
6.55
7.11
7.72
7.85
9.09
10.19
11.30
11.91
13.94
COLORCODE
Black/Red
1
1
1
1
1
2
2
Black/Red
1
1
1
1
1
1
1
2
2
2
2
25.0
25.0
25.0
25.0
25.0
25.0
25.0
25.0
27.5
27.5
27.5
27.5
27.5
27.5
27.5
27.5
27.5
27.5
27.5
27.5
Product Construction:Conductor:• 20 or 18 AWG fully annealed, stranded
tinned copper per ASTM B-33
Insulation:• Premium-grade, coIor-coded PVC• Color Code: See charts below
Jacket:• PVC, gray• Temperature Range: –20˚C to +105°C
Applications:• Public address systems• Intercoms• Internal telephones• Remote control circuits• Suitable for EIA RS-232 applications• Suggested voltage rating: 300 or 600 volts
Features:• Easy to terminate• Excellent electrical properties• Tinned conductors provide excellent
corrosion resistance• Assists soldering applications
Compliances:• AWM Style 2464 (CSA: 80˚C, 300V)• CSA Type AWM (105˚C, 600V)• CSA Certified CMG to harmonized standard
UL444 and CSA 22.2 No. 214• NEC/CEC Type CMG (CSA: 105˚C, 300V)• Designed to Meet CSA 70,000 BTU Vertical
Tray Flame Test• Passes CSA FT4 vertical flame test
Packaging:• Please contact Customer Service for
packaging and color options
*Capacitance between conductors
Color Code Chart 1 - For cables up to and including 9 conductors
12345
NO. OFCOND. COLOR
BlackWhiteRedGreenBrown
6789
NO. OFCOND. COLOR
BlueOrangeYellowViolet
Color Code Chart 2 Per ICEA - For cables of 12 thru 25 conductors
123456789
NO. OFCOND. COLOR
BlackWhiteRedGreenOrangeBlueWhite/BlackRed/BlackGreen/Black
101112131415161718
NO. OFCOND. COLOR
Orange/BlackBlue/BlackBlack/WhiteRed/WhiteGreen/WhiteBlue/WhiteBlack/RedWhite/RedOrange/Red
19202122232425
NO. OFCOND. COLOR
Blue/RedRed/GreenOrange/GreenBlack/White/RedWhite/Black/RedRed/Black/WhiteGreen/Black/White
175
Electronics CSA Approved Cable
Product Construction:Conductor:• 16 thru 12 AWG fully annealed, stranded
tinned copper per ASTM B-33
Insulation:• Premium-grade, coIor-coded PVC• Color Code: See chart below
Jacket:• PVC, gray• Temperature Range: –20°C to + 105°C
Applications:• Public address systems• Intercoms• Internal telephones• Remote control circuits• Suitable for EIA RS-232 applications• Suggested voltage rating: 300 or 600 volts
Features:• Easy to terminate• Excellent electrical properties• Tinned conductors provide excellent
corrosion resistance• Assists soldering applications
Compliances:• AWM Style 2464 (CSA or UL: 80˚C, 300V)• AWM Style 2587 (CSA: 90˚C, 600V)• CSA Type AWM (105˚C, 600V)• CSA Certified CMG to harmonized standard
UL444 and CSA 22.2 No. 214• NEC/CEC Type CMG (CSA: 105˚C, 300V)• Designed to Meet CSA 70,000 BTU Vertical
Tray Flame Test• Passes CSA FT4 Vertical Flame Test• UL Certified CL2 to Standard UL13• Designed to meet UL 70,000 BTU Vertical
Tray Flame TestPackaging:
• Please contact Customer Service forpackaging and color options
Multi-Conductor, UnshieldedAWM Styles 2464, 2587, CSA Type AWM, NEC/CEC Type CMG (CSA C/US), or NEC Type CL2
CATALOGNUMBER
NO. OFCOND.
AWGSIZE
COND.STRAND.
NOM. INSULATIONTHICKNESS
INCHES
C4135C4136C4137C4138C4139C4140C4141C4142C4143C4144C4145
2
3
4
5
7
8
9
12
15
19
25
16
16
16
16
16
16
16
16
16
16
16
19/.0117
19/.0117
19/.0117
19/.0117
19/.0117
19/.0117
19/.0117
19/.0117
19/.0117
19/.0117
19/.0117
mm
0.021
0.021
0.021
0.021
0.021
0.021
0.021
0.021
0.021
0.021
0.021
0.53
0.53
0.53
0.53
0 53
0.53
0.53
0 53
0 53
0.53
0.53
NOM. JACKETTHICKNESS
INCHES mm
0.032
0.032
0.032
0.032
0.032
0.032
0.032
0.032
0.032
0.032
0.032
0.81
0.81
0.81
0.81
0.81
0.81
0.81
0.81
0.81
0.81
0.81
NOMINAL O.D.
NOM.C-C
CAP.**pF/ftINCHES mm
0.268
0.283
0.306
0.334
0.364
0.395
0.425
0.479
0.530
0.564
0.657
6.81
7.19
7.77
8.48
9.25
10.03
10.80
12.17
13.46
14.33
16.69
27.0
27.0
27.0
27.0
27.0
27.0
27.0
27.0
27.0
27.0
27.0
AWM STYLE 2464, CSA type AWM, CSA C/US Type CMG
C4146C4147C4148C4149C4150C4151
2
4
5
7
2
4
14
14
14
14
12
12
19/.0147
19/.0147
19/.0147
19/.0147
19/.0185
19/.0185
0.032
0.032
0.032
0.032
0.032
0.032
0.81
0.81
0.81
0.81
0.81
0.81
0.032
0.032
0.032
0.032
0.032
0.032
0.81
0.81
0.81
0.81
0.81
0.81
0.326
0.391
0.428
0.469
0.370
0.434
8.28
9.93
10.87
11.91
9.40
11.02
25.0
25.0
25.0
25.0
29.4
29.4
AWM Style 2587, CSA Type AWM (FT4), NEC Type CL2*
**Capacitance between conductors
Color Code Chart Per ICEA
123456789
NO. OFCOND. COLOR
BlackWhiteRedGreenOrangeBlueWhite/BlackRed/BlackGreen/Black
101112131415161718
NO. OFCOND. COLOR
Orange/BlackBlue/BlackBlack/WhiteRed/WhiteGreen/WhiteBlue/WhiteBlack/RedWhite/RedOrange/Red
19202122232425
NO. OFCOND. COLOR
Blue/RedRed/GreenOrange/GreenBlack/White/RedWhite/Black/RedRed/Black/WhiteGreen/Black/White
176
CSA Approved Cable Electronics
C4163
Product Construction:Conductor:• 24 thru 12 AWG fully annealed solid or
stranded tinned copper per ASTM B-33
Insulation:• Premium-grade, coIor-coded polypropylene• Color Code: See charts below
Shield:• 100% Flexfoil® aluminum/polyester,
25% overlap, foil facing out• Stranded tinned copper drain wire
Jacket:• PVC, gray• Temperature Range: –20°C to +80°C
Applications:• Recording studios and sound stages• Broadcast and sound systems• Computers• Industrial equipment control• Suggested voltage rating: 300 or 600 volts
Features:• Excellent electrical properties• Superior shielding effectiveness • 25% shield overlap provides excellent
shielding efficiency• Good flexibility
Compliances:• AWM Style 20251 (CSA: 60˚C, 150V, 300V
peak)• CSA Type AWM (80˚C, 600V)• CSA Certified CMG to harmonized standard
UL444 and CSA 22.2 No. 214• NEC/CEC Type CMG (CSA: 80˚C, 300V)• Designed to Meet CSA 70,000 BTU Vertical
Tray Flame Test• Passes CSA FT4 Vertical Flame Test
Packaging:• Please contact Customer Service for
packaging and color options
Multi-Conductor, Foil ShieldVarious AWM Styles, CSA Type AWM, NEC/CEC Type CMG (CSA C/US)
CATALOGNUMBER
NO. OFCOND.
AWGSIZE
COND.STRAND.
NOM. INSULATIONTHICKNESS
NOM. JACKETTHICKNESS NOMINAL O.D.
NOM. CAP.*pF/ft
INCHES mm INCHES mm INCHES mm A B
C4152C4153C4154C4155C4156C4157C4158C4159C4160C4161
2
2
2
2
3
3
3
3
4
4
24
22
20
18
22
20
20
18
22
20
7/32
7/30
7/28
16/30
7/30
7/28
7/28
16/30
7/30
7/28
0.016
0.016
0.016
0.018
0.016
0.016
0.016
0.018
0.016
0.016
0.41
0.41
0.41
0.46
0.41
0.41
0.41
0.46
0.41
0.41
0.026
0.026
0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.66
0.66
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.167
0.179
0.203
0.233
0.196
0.210
0.213
0.247
0.213
0.234
4.24
4.55
5.16
5.92
4.98
5.33
5.41
6.27
5.41
5.94
23.0
21.0
22.0
24.0
25.0
27.0
29.0
22.0
23.0
26.0
42.0
38.0
40.0
43.0
45.0
51.0
52.0
40.0
42.0
74.0
AWM STYLE 20251, CSA TYPE AWM, CSA C/US TYPE CMG
Color Code Chart #3
Color Code Chart #1
Color Code Chart #1
Color Code Chart #1
Polypropylene Insulation, Color Code Chart #2*A - Capacitance between conductors*B - Capacitance between one conductor and other conductors connected to shield
C4162C4165
2
3
16
16
19/.0117
19/.0117
0.032
0.032
0.81
0.81
0.032
0.032
0.81
0.81
0.307
0.326
7.80
8.28
27.0
26.0
49.0
46.0
CSA TYPE AWM, CSA C/US TYPE CMG
C4167C4168C4169
2
2
3
22
22
22
Solid
7/30
7/30
0.007
0.008
0.008
0.18
0.20
0.20
0.020
0.020
0.020
0.51
0.51
0.51
0.124
0.137
0.144
3.15
3.48
3.66
40.0
34.0
32.0
76.0
67.0
60.0
AWM STYLE 20251, CSA TYPE AWM, CSA C/US TYPE CMG
2 14 41/30 0.020 0.51 0.032 0.81 0.295 7.49 31.0 56.0
AWM STYLE 2464, CSA TYPE AWM
C4164 2 12 19/.0185 0.032 0.81 0.040 1.02 0.376 9.55 35.0 63.0
CSA TYPE AWM
Color Code Chart 1
1234
NO. OF COND. COLOR
BlackNaturalRedGreen
Color Code Chart 2
123
NO. OF COND. COLOR
BlackRedClear
Color Code Chart 3
12
NO. OF COND. COLOR
BlackWhite
177
Electronics CSA Approved Cable
Product Construction:Conductor:• 24 thru 12 AWG fully annealed solid or
stranded tinned copper per ASTM B-33
Insulation:• Premium-grade, coIor-coded PVC• Color Code: See charts below
Shield:• 100% Flexfoil® aluminum/polyester,
25% overlap, foil facing out• Stranded tinned copper drain wire
Jacket:• PVC, gray• Temperature Range: –20°C to + 75°C
Applications:• Recording studios and sound stages• Broadcast and sound systems• Industrial equipment control• Suitable for EIA RS-232 applications• Suggested voltage rating: 300 or 600 volts
Features:• Superior shielding effectiveness • 25% shield overlap provides excellent
shielding efficiency• Good flexibility
Compliances:• AWM Style 2464 (UL or CSA: 80˚C, 300V)• CSA Type AWM (105˚C, 600V)• CSA Certified CMG to harmonized standard
UL444 and CSA 22.2 No. 214 • NEC/CEC Type CMG (CSA: 105˚C, 300V)• Designed to Meet CSA 70,000 BTU Vertical
Tray Flame Test• Passes CSA FT4 Vertical Flame Test• UL Certified CL2 to Standard UL 13*• Designed to Meet CSA 70,000 BTU Vertical
Tray Flame Test
Packaging:• Please contact Customer Service for
packaging and color options
CATALOGNUMBER
NO. OFCOND.
AWGSIZE
COND.STRAND.
NOM. INSULATIONTHICKNESS
NOM. JACKETTHICKNESS NOMINAL O.D.
NOM. CAP.**pF/ftCOLOR
CODEINCHES mm INCHES mm INCHES mm A B
C4192C4210C4193C4194C4207C4208C4166C4211C4195C4196C4197C4212C4198C4204C4205C4199C4213C4200
2
2
3
4
6
8
2
2
3
4
2
2
3
4
6
2
2
3
1
2
2
2
2
2
1
2
2
2
1
2
2
2
2
1
2
2
22
22
22
22
22
22
20
20
20
20
18
18
18
18
18
16
16
16
7/30
7/30
7/30
7/30
7/30
7/30
7/28
7/28
7/28
7/28
16/30
16/30
16/30
16/30
16/30
19/.0117
19/.0117
19/.0117
0.009
0.009
0.009
0.009
0.009
0.009
0.012
0.012
0.012
0.012
0.012
0.012
0.012
0.012
0.012
0.010
0.010
0.010
0.23
0.23
0.23
0.23
0.23
0.23
0.30
0.30
0.30
0.30
0.30
0.30
0.30
0.30
0.30
0.25
0.25
0.25
0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.165
0.165
0.173
0.188
0.204
0.219
0.180
0.180
0.200
0.216
0.209
0.209
0.223
0.236
0.267
0.218
0.218
0.230
4.19
4.19
4.39
4.78
5.18
5.56
4.57
4.57
5.08
5.49
5.31
5.31
5.66
5.99
6.78
5.54
5.54
5.84
47.0
47.0
43.0
43.0
43.0
43.0
46.0
46.0
42.0
42.0
51.0
51.0
46.0
46.0
46.0
62.0
62.0
58.0
85.0
85.0
76.0
76.0
76.0
76.0
83.0
83.0
75.0
75.0
92.0
92.0
83.0
83.0
83.0
112.0
112.0
104.0
AWM Style 2464, CSA Type AWM, CSA C/US Type CMG
**A - Capacitance between conductors**B - Capacitance between one conductor and other conductors connected to shield
C4201C4215C4202
2
2
2
1
2
1
14
14
12
19/.0147
19/.0147
19/.0185
0.014
0.014
0.014
0.36
0.36
0.36
0.030
0.030
0.030
0.76
0.76
0.76
0.268
0.268
0.302
6.81
6.81
7.67
60.0
60.0
64.0
107.0
107.0
116.0
AWM STYLE 2464, CSA TYPE AWM (FT4), NEC TYPE CL2*
Color Code Chart 1
12
NO. OF COND. COLOR
BlackRed
Color Code Chart 2
12345678
NO. OF COND. COLOR
BlackWhiteRedGreenBrownBlueOrangeYellow
Multi-Conductor, Foil ShieldAWM Styles 2464, CSA Type AWM, NEC/CEC Type CMG (CSA C/US), or NEC Type CL2
178
CSA Approved Cable Electronics
Multi-Paired, Foil ShieldAWM Style 2464, CSA Type AWM, NEC/CEC Type CMG (CSA C/US)
Product Construction:Conductor:• 24 AWG fully annealed stranded tinned
copper per ASTM B-33• Twisted pairs
Insulation:• Premium-grade, coIor-coded PVC• Color Code: See chart below
Shield:• 100% Flexfoil® aluminum/polyester,
25% overlap, foil facing out• Stranded tinned copper drain wire
Jacket:• PVC, gray• Temperature Range: –20°C to +105°C
Applications:• Computers• Industrial equipment• Data transmission• Control circuits• Suitable for EIA RS-232 applications• Suggested voltage rating: 300 or 600 volts
Features:• Excellent electrical properties• Superior shielding effectiveness • 25% shield overlap provides excellent
shielding efficiency• Assists system designers in meeting FCC
Docket 20780 demands• Good flexibility
Compliances:• AWM Style 2464 (CSA: 80˚C, 300V)• CSA Type AWM (105˚C, 600V)• CSA Certified CMG to harmonized standard
UL444 and CSA 22.2 No. 214• NEC/CEC Type CMG (CSA: 105˚C, 300V)• Designed to Meet CSA 70,000 BTU Vertical
Tray Flame Test• Passes CSA FT4 Vertical Flame Test
Packaging:• Please contact Customer Service for
packaging and color options
*A - Capacitance between conductors*B - Capacitance between one conductor and other conductors connected to shield
Color Code Chart
12345678910111213
NO. OFPAIRS COLOR
Black with RedBlack with WhiteBlack with GreenBlack with BlueBlack with YellowBlack with BrownBlack with OrangeRed with WhiteRed with GreenRed with BlueRed with YellowRed with BrownRed with Orange
NO. OFPAIRS COLOR
141516171819202122232425
Green with WhiteGreen with BlueGreen with YellowGreen with BrownGreen with OrangeWhite with BlueWhite with YellowWhite with BrownWhite with OrangeBlue with YellowBlue with BrownBlue with Orange
CATALOGNUMBER
NO.OF
PAIRSAWGSIZE
COND.STRAND.
NOM. INSULATIONTHICKNESS
NOM. JACKETTHICKNESS NOMINAL O.D.
NOM. CAP.*pF/ftCOLOR
CODEINCHES mm INCHES mm INCHES mm A B
C4170C4209C4191 C4171C4172C4173C4174C4175C4176C4177C4178C4179C4180C4181C4182
1
1
2
2
3
4
5
6
7
8
9
10
15
19
25
1
Wht/Blk
Blk/Red
1
1
1
1
1
1
1
1
1
1
1
1
24
24
24
24
24
24
24
24
24
24
24
24
24
24
24
7/32
7/32
7/32
7/32
7/32
7/32
7/32
7/32
7/32
7/32
7/32
7/32
7/32
7/32
7/32
NOMINALDCRΩ/KFT
COND SHLD
0.010
0.010
0.009
0.010
0.010
0.010
0.010
0.010
0.010
0.010
0.010
0.010
0.010
0.010
0.010
0.25
0.25
0.23
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.032
0.032
0.030
0.032
0.032
0.032
0.032
0.032
0.032
0.032
0.032
0.032
0.032
0.032
0.032
0.81
0.81
0.76
0.81
0.81
0.81
0.81
0.81
0.81
0.81
0.81
0.81
0.81
0.81
0.81
0.157
0.157
0.153
0.214
0.225
0.245
0.265
0.287
0.287
0.309
0.331
0.359
0.410
0.432
0.505
3.99
3.99
3.89
5.44
5.72
6.22
6.73
7.29
7.29
7.85
8.41
9.12
10.41
10.97
12.83
26.0
26.0
26.0
26.0
26.0
26.0
26.0
26.0
26.0
26.0
26.0
26.0
26.0
26.0
26.0
18.0
18.0
16.5
18.0
16.5
16.5
16.5
15.2
15.2
15.0
15.0
14.0
13.8
13.5
12.7
36.4
36.4
43
31.9
28.6
28.6
28.6
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
65.5
65.5
78
57.3
51.4
51.4
51.4
47.5
47.5
47.5
47.5
47.5
47.5
47.5
47.5
179
Electronics CSA Approved Cable
Multi-Paired, Foil ShieldAWM Style 2464, CSA Type AWM, NEC/CEC Type CMG (CSA C/US)
Product Construction:Conductor:• 22 AWG fully annealed stranded tinned
copper per ASTM B-33• Twisted pairs
Insulation:• Premium-grade, coIor-coded PVC• Color Code: See chart below
Shield:• 100% Flexfoil® aluminum/polyester,
25% overlap, foil facing out• Stranded tinned copper drain wire
Jacket:• PVC, gray• Temperature Range: –20°C to +105°C
Applications:• Computers• Industrial equipment• Data transmission• Control circuits• Suitable for EIA RS-232 applications• Suggested voltage ratings: 300 or 600 volts
Features:• Excellent electrical properties• Superior shielding effectiveness • 25% shield overlap provides excellent
shielding efficiency• Assists system designers in meeting FCC
Docket 20780 demands• Good flexibility
Compliances:• AWM Style 2464 (CSA: 80˚C, 300V)• CSA Type AWM (105˚C, 600V)• CSA Certified CMG to harmonized standard
UL444 and CSA 22.2 No. 214• NEC/CEC Type CMG (CSA: 105˚C, 300V)• Designed to Meet CSA 70,000 BTU Vertical
Tray Flame Test• Passes CSA FT4 Vertical Flame Test
Packaging:• Please contact Customer Service for
packaging and color options
*A - Capacitance between conductors*B - Capacitance between one conductor and other conductors connected to shield
CATALOGNUMBER
NO.OF
PAIRSAWGSIZE
COND.STRAND.
NOM. INSULATIONTHICKNESS
NOM. JACKETTHICKNESS NOMINAL O.D.
NOM. CAP.*pF/ft
INCHES mm INCHES mm INCHES mm A B
C4183C4184C4185C4186C4187C4188C4189C4190
1
2
3
4
5
6
9
15
22
22
22
22
22
22
22
22
7/30
7/30
7/30
7/30
7/30
7/30
7/30
7/30
NOMINALDCRΩ/KFT
COND SHLD
0.010
0.010
0.010
0.010
0.010
0.010
0.010
0.010
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.032
0.032
0.032
0.032
0.032
0.032
0.032
0.032
0.81
0.81
0.81
0.81
0.81
0.81
0.81
0.81
0.169
0.234
0.246
0.269
0.292
0.317
0.367
0.457
4.29
5.94
6.25
6.83
7.42
8.05
9.32
11.61
15.0
15.0
15.0
15.0
15.0
15.0
15.0
15.0
18.0
16.5
16.5
16.5
16.5
16.5
16.5
16.5
44.8
35.9
30.9
30.9
30.9
28.4
28.4
28.4
80.7
64.6
55.7
55.7
55.7
51.0
51.0
51.0
Color Code Chart
12345678
NO. OFPAIRS COLOR
Black with RedBlack with WhiteBlack with GreenBlack with BlueBlack with YellowBlack with BrownBlack with OrangeRed with White
NO. OFPAIRS COLOR
9101112131415
Red with GreenRed with BlueRed with YellowRed with BrownRed with OrangeGreen with WhiteGreen with Blue
180
CSA Approved Cable Electronics
24
24
24
24
24
24
24
24
24
Product Construction:Conductor:• 24 AWG fully annealed stranded tinned
copper per ASTM B-33
Insulation:• Premium-grade, coIor-coded PVC • Color Code: See charts below
Shield:• 100% Flexfoil® aluminum/polyester
with 25% overlap, foil facing out• Stranded tinned copper drain wire
Jacket:• PVC, gray• Temperature Range: –20˚C to +105˚C
Applications:• Computer interconnections• Data transmission• Control circuits• Industrial equipment control• Suitable for EIA RS-232 applications• Suggested voltage rating: 300 or 600 volts
Features:• Superior shielding effectiveness • 25% shield overlap provides excellent
shielding efficiency• Good flexibility
Compliances:• AWM Style 2464 (UL or CSA: 80˚C, 300V)• CSA Type AWM (105˚C, 600V)• CSA Certified CMG to harmonized standard
UL444 and CSA 22.2 No. 214• NEC/CEC Type CMG (CSA: 105˚C, 300V)• Designed to Meet CSA 70,000 BTU Vertical
Tray Flame Test• Passes CSA FT4 Vertical Flame Test
Packaging:• Please contact Customer Service for
packaging and color options
Multi-Conductor, Foil ShieldAWM Style 2464, CSA Type AWM, NEC/CEC Type CMG (CSA C/US)
CATALOGNUMBER
C4216C4217C4218C4219C4220C4221C4222C4223C4224
2
3
4
5
6
7
8
9
10
Color Code Chart 2 Per ICEA - For cables of 15 to 50 conductors
123456789
1011121314151617
BlackWhiteRedGreenOrangeBlueWhite/BlackRed/BlackGreen/BlackOrange/BlackBlue/BlackBlack/WhiteRed/WhiteGreen/WhiteBlue/WhiteBlack/RedWhite/Red
1819202122232425262728293031323334
Orange/RedBlue/RedRed/GreenOrange/GreenBlack/White/RedWhite/Black/RedRed/Black/WhiteGreen/Black/WhiteOrange/Black/WhiteBlue/Black/WhiteBlack/Red/GreenWhite/Red/GreenRed/Black/GreenGreen/Black/OrangeOrange/Black/GreenBlue/White/OrangeBlack/White/Orange
35363738394041424344454647484950
White/Red/OrangeOrange/White/BlueWhite/Red/BlueBlack/White/GreenWhite/Black/GreenRed/White/GreenGreen/White/BlueOrange/Red/GreenBlue/Red/GreenBlack/White/BlueWhite/Black/BlueRed/White/BlueGreen/Orange/RedOrange/Red/BlueBlue/Red/OrangeBlack/Orange/Red
AWM STYLE 2464, CSA TYPE AWM, CSA C/US TYPE CMG
NO. OFCOND.
AWGSIZE
7/32
7/32
7/32
7/32
7/32
7/32
7/32
7/32
7/32
COND.STRAND.
NOM.INSULATIONTHICKNESS
INCHES mm
NOM. JACKET
THICKNESSINCHES mm
NOMINALO.D.
INCHES mm
NOMINAL DCRΩ/kft
@ 20˚CCOND. SHLD.
NOMINAL CAP.*pF/ft
A B
0.010
0.010
0.010
0.010
0.010
0.010
0.010
0.010
0.010
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.032
0.032
0.032
0.032
0.032
0.032
0.032
0.032
0.032
0.81
0.81
0.81
0.81
0.81
0.81
0.81
0.81
0.81
0.157
0.164
0.175
0.188
0.201
0.201
0.215
0.228
0.245
3.99
4.17
4.45
4.78
5.11
5.11
5.46
5.79
6.22
26.0
26.0
26.0
26.0
26.0
26.0
26.0
26.0
26.0
18.0
18.0
18.0
16.0
16.0
16.0
16.0
16.0
14.0
40.0
36.0
36.0
36.0
34.0
34.0
34.0
34.0
34.0
72.0
66.0
66.0
66.0
61.0
61.0
61.0
61.0
61.0
C4225C4226C4227C4228C4229C4230
15
20
25
30
40
50
24
24
24
24
24
24
7/32
7/32
7/32
7/32
7/32
7/32
0.010
0.010
0.010
0.010
0.010
0.010
0.25
0.25
0.25
0.25
0.25
0.25
0.032
0.032
0.032
0.032
0.032
0.032
0.81
0.81
0.81
0.81
0.81
0.81
0.276
0.303
0.333
0.351
0.391
0.439
7.01
7.70
8.46
8.92
9.93
11.15
26.0
26.0
26.0
26.0
26.0
26.0
14.0
14.0
12.0
12.0
12.0
10.0
34.0
34.0
34.0
34.0
34.0
34.0
61.0
61.0
61.0
61.0
61.0
61.0 Color code chart #2*A - Capacitance between conductors*B - Capacitance between one conductor and other conductors connected to shield
Color code chart #1
Color Code Chart 1 - For cables up to and including 10 conductors
12345
NO. OFCOND. COLOR
BlackWhiteRedGreenBrown
6789
10
NO. OFCOND. COLOR
BlueOrangeYellowVioletGray
NO. OFCOND. COLOR
NO. OFCOND. COLOR
NO. OFCOND. COLOR
181
Electronics CSA Approved Cable
Product Construction:Conductor:• 22 AWG fully annealed stranded tinned
copper per ASTM B-33• Twisted pairs
Insulation:• Premium-grade, coIor-coded PVC • Color Code: See chart below
Shield:• Individually shielded pairs• 100% Flexfoil® aluminum/polyester,
25% overlap, foil facing out• Stranded tinned copper drain wire
Jacket:• PVC, gray• Temperature range: –20˚C to + 105˚C
Applications:• Where total isolation of signal is required• Computers• Control circuits• Industrial equipment • Suggested voltage rating: 300 or 600 volts
Features:• Excellent high-frequency properties• Mechanical durability
Compliances:• CSA Type AWM (105˚C, 600V)• CSA Certified CMG to harmonized standard
UL444 and CSA (CSA: 105˚C, 300V)• Designed to Meet CSA 70,000 BTU Vertical
Tray Flame Test• Passes CSA FT4 Vertical Flame Test
Packaging:• Please contact Customer Service for
packaging and color options
Multi-Paired, Individually ShieldedCSA Type AWM I/II A/B, NEC/CEC Type CMG (CSA C/US)
*A - Capacitance between conductors*B - Capacitance between one conductor and other conductors connected to shield
CATALOGNUMBER
NO.OF
PAIRSAWGSIZE
COND.STRAND.
NOM. INSULATIONTHICKNESS
NOM. JACKETTHICKNESS NOMINAL O.D.
NOM. CAP.*pF/ft
INCHES mm INCHES mm INCHES mm A B
C4203 2 22 7/30
NOMINALDCRΩ/KFT
COND SHLD
0.007 0.18 0.020 0.51 0.160 4.06 16.6 7.2 67.0 121.0
Color Code Chart
12
NO. OFPAIRS COLOR
Black with RedGreen with White
182
Electronics
Index PageInsulation & JacketProperties 183Decimal ConversionFactors 184Unit Conversion Factors 185Temperature ConversionChart 186Conduit CapacityChart 187Coax Connector Cross Reference 188-195AWG Conductor Chart 196Cable Design Equations—
Braid Shield 197Coaxial Cable 198Balanced Pair 199
Engineering Prefixes 200Glossary 201-211Abbreviations &Acronyms 212-214Product Finders—
Hook-Up Wire 215Multi-Conductor Cable 216-218Multi-Paired Cable 219-220
NEC SubstitutionChart 221-222Agency Symbols 223Put-Ups and Color Codes 224Product DescriptionIndex 225-227Belden-to-General CableCarol® Brand Cross Reference Index 228-233Part Number Index 234-236Notes 237-238
As technology becomesmore complex, specifying wireand cable products to meetsystem performance demandsbecomes more time-consumingand complex.
Today’s system designermust be aware not only of thegeneral transmission line types,but also of the myriad ofmaterials available to meetspecific environmental orelectrical performance criteria.
This technical section ispresented to aid in theselection of materials anddesigns which will best suit thecombination of hardware andtransmission media.
For technical questionsregarding specific transmissiondesigns or applications, pleasecontact General Cable’sEngineering Department.
Technical Information 13
183
Electronics Technical Information
Insulation & Jacket Properties
Specific GravityDielectric Constant(a) 60 Hz(b) 1000 HzDielectric Strength, v/mil(a) 0.010" wall(b) 0.040" wallTensile Strength, PSI x 1000Service Temp, Range, °CElongation, %Water Absorption, % in 24 hr
Flame Resistance
Ozone ResistanceFlexibilityAbrasion ResistanceAcid ResistanceBase ResistanceHydraulic Fluid ResistanceOrganic Solvent Resistance
1.37
6.05.0
1800800
1.5-3.8– 55/+105200-375
<0.75
SelfExtinguishing
ExcellentGoodGood
ExcellentExcellentGood-FairFair-Poor
0.92
2.262.26
21001050
1.4-2.4– 90/+ 90350-550
<0.02
SupportsFlame
GoodGoodGood
ExcellentExcellentFair-Poor
Poor
.89
2.6
850450
2.9-4.5– 40/+105
700<0.02
SupportsFlame
ExcellentGoodFair
ExcellentExcellent
FairFair
0.93-1.18
3.03.0
–700
1.8-2.5– 80/+75250-400
<0.01
SlowFlame
GoodGood-FairExcellentExcellentExcellentGood-Fair
Fair
1.09
4.64.5
1000470
8.8-11.9– 55/+105150-380
2.5
SelfExtinguishing
GoodGood-FairExcellentExcellentExcellentGood-FairGood-Fair
2.16
2.152.15
2000950
2.3-3.1– 90/+ 200200-330
<0.01
Non-Flammable
ExcellentGood
ExcellentPoor
ExcellentExcellentExcellent
2.17
2.12.1
2000950
2.0-6.0– 90/+ 260200-500
<0.01
Non-Flammable
ExcellentGood
ExcellentExcellentExcellentExcellentExcellent
1.40
4.14.0
700500
0.5-1.5– 40/+ 90200-400
<1.0
SlowBurning
ExcellentExcellent
PoorExcellent
GoodPoor
Good-Fair
1.24
3.33.1
600400
0.6-1.2– 80/+ 200125-400
<1.0Slow
(Non-Cond.Ash)
ExcellentExcellent
PoorGoodGood
Fair-PoorPoor
1.16-1.20
2.82.8
625
2.3– 55/+ 90
500<0.6
Flammable
ExcellentExcellentGood-FairExcellentExcellent
PoorPoor
NOTE: The above is representative of performance. For specific compound performance, consult Customer Service.
Specific GravityTensile Strength, PSI x 1000Elongation, %Service Temp, Range, °COzone Resistance
Weatherability
Flame Resistance
FlexibilityAbrasion ResistanceAcid ResistanceBase ResistanceHydraulic Fluid ResistanceOrganic Solvent ResistanceResistance to Tearing
NOTE: The above is representative of performance. For specific compound performance, consult Customer Service.
1.371.5-3.8
200-375– 55/+105Excellent
Good-Fair
SelfExtinguishing
GoodGood
ExcellentExcellentGood-FairFair-Poor
Good
0.921.4-2.4
350-550– 80/+75
GoodExcellent
GoodSupports
Flame
GoodGood
ExcellentExcellentFair-Poor
PoorGood
1.098.8-11.9150-380
– 55/+105Good
Fair-Poor
Flammable
Good-FairExcellent
PoorExcellentGood-FairGood-FairExcellent
2.162.3-3.1
200-330– 90/+ 200Excellent
Excellent
Non-Flammable
GoodExcellentExcellentExcellentExcellentExcellent
Good
2.172.0-6.0
200-500– 90/+ 200Excellent
Excellent
Non-Flammable
GoodExcellentExcellentExcellentExcellentExcellent
Good
1.240.6-1.2
125-400– 80/+ 200Excellent
Excellent
Slow-Burn(Non-Cond.
Ash)Excellent
PoorPoorGood
Fair-PoorPoorFair
1.522.5-4.0
300-500– 65/+ 90Excellent
Good
Self-Extinguishing
ExcellentExcellent
GoodGoodGoodGoodGood
1.3>3.5
540-700– 65/+75
Good
Good
Slow Burn
ExcellentExcellent
FairFairPoorPoor
Excellent
1.16-1.202.3500
– 55/+ 90Excellent
Excellent
Flammable
ExcellentGood-FairExcellentExcellent
GoodPoor
Good-Fair
TYPICAL PROPERTIES OF COMMON INSULATING MATERIALS
PARAMETER PVC PE PP XLPE NYLON FEP TFEBUTYL
RUBBERSILICONERUBBER TPR
TYPICAL PROPERTIES OF COMMON JACKETING MATERIALS
PARAMETER PVC PE NYLON FEP TFESILICONERUBBER NEOPRENE
POLY-URETHANE TPR
184
Technical Information Electronics
FRACTIONS, DECIMALS AND MILLIMETER CONVERSION CHARTFRACTIONS OF AN INCH EQUIVALENTS FRACTIONS OF AN INCH EQUIVALENTS
643334353637
3839404142
4344454647
4849505152
5354555657
5859606162
6364
32
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
16
9
10
11
12
13
14
15
16
8
5
6
7
8
4
3
4
2
2
DECIMAL0.5160.5310.5470.5630.578
0.5940.6090.6250.6410.656
0.6720.6880.7030.7190.734
0.7500.7660.7810.7970.813
0.8280.8440.8590.8750.891
0.9060.9220.9380.9530.969
0.9841.000
mm13.1013.4913.8914.2914.68
15.0815.4815.8816.2716.67
17.0717.4617.8618.2618.65
19.0519.4519.8420.2420.64
21.0321.4321.8322.2322.62
23.0223.4223.8124.2124.61
25.0025.40
6412345
6789
10
1112131415
1617181920
2122232425
2627282930
3132
32
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
16
1
2
3
4
5
6
7
8
8
1
2
3
4
4
1
2
2
1
DECIMAL0.0160.0310.0470.0630.078
0.0940.1090.1250.1410.156
0.1720.1880.2030.2190.234
0.2500.2660.2810.2970.313
0.3280.3440.3590.3750.391
0.4060.4220.4380.4530.469
0.4840.500
mm0.400.791.191.591.98
2.382.783.183.573.97
4.374.765.165.565.95
6.356.757.147.547.94
8.338.739.139.539.92
10.3210.7211.1111.5111.91
12.3012.70
Decimal Conversion Factors
185
Electronics Technical Information
Unit Conversion Factors
gallons (gal)gallons (gal)gallons (gal)gallons (gal)
grams (g)gram/centimeter3 (gm/cm3)
horsepower (hp)horsepower (hp)horsepower (hp)
inch (in)inch (in)inch (in)inch (in)inch (in)inch (in)inch (in)joules (j)joules (j)liters (l)
meters (m)meters (m)meters (m)meters (m)miles (mi)miles (mi)miles (mi)
millimeters (mm)millimeters (mm)millimeters (mm)millimeters (mm)millimeters (mm)millimeters (mm)
watts (w)watts (w)watts (w)
watt-hours (w-hr)
3.7854110.13368
231.03785.411
15.4320.036127533013.26
550.0745.7
0.0271780.083333
0.000025400.025400
2.5400051425.4000514
1000.00.000948
107
61.023741.093611
3.280833339.37100.0
1760.05280.01.6093
0.00328080.03937
0.0010.01
39.37011000.044.25
0.7375620.0013413.414462
liters (l))cubic foot (ft3)cubic in. (in3)
cubic centimeter (cm3)grains
pounds/in3 (lb/in3)ft-lb/minft-lb/secwatts (w)yards (yd)
feet (ft)kilometer (km)
meter (m)centimeter (cm)millimeter (mm)
milsBritish Thermal Unit (BTU)
ergscubic inch (in3)
yard (yd)feet (ft)inch (in)
centimeter (cm)yards (yd)
feet (ft)kilometer (km)
feet (ft)inch (in)
meters (m)centimeters (cm)
milsmicrons (µ)ft-lb/minute
ft-lb/sechorsepower
British Thermal Unit (BTU)
UNIT CONSTANT UNITX =UNIT CONSTANT UNITBritish Thermal Unit (BTU)British Thermal Unit (BTU)British Thermal Unit (BTU)
centimeters (cm)centimeters (cm)centimeters (cm)centimeters (cm)centimeters (cm)
circular mils (cmil)circular mils (cmil)circular mils (cmil)circular mils (cmil)
cubic centimeter (cm3)cubic centimeter (cm3)cubic centimeter (cm3)cubic centimeter (cm3)
cubic foot (ft3)cubic foot (ft3)cubic inch (in3)cubic inch (in3)cubic inch (in3)
cubic meter (m3)cubic meter (m3)cubic meter (m3)
feet (ft)feet (ft)feet (ft)feet (ft)feet (ft)feet (ft)feet (ft)
feet/pound (ft/lb)foot-pound (ft-lb)foot-pound (ft-lb)foot-pound (ft-lb)
778.01054.35
0.2930.032808
0.39370.00001
0.01010.0
0.000645160.0000007854
0.000506710.7854
0.0000353140.0610230.000001
0.000264171728.0
28317.8470.00057870
0.00001638716.3870641000000.035.314666
264.170.00018939
0.3333312
0.000304800.3048030.480304.80
0.000671970.001285
1.3560.1383
foot-pound (ft-lb)joules (j)
watt-hours (w-hr)feet (ft)
inches (in)kilometers (km)
meters (m)millimeters (mm)
circular millimetersinches2 (in2)
square millimeters (mm2)mils2
cubic foot (ft3)cubic inch (in3)
cubic meter (m3)gallons (gal)cubic in (in3)
cubic centimeter (cm3)cubic feet (ft3)
cubic meter (m3)cubic centimeter (cm3)
centimeter (cm)cubic foot (ft3)gallons (gal)
miles (mi)yards (yd)inches (in)
kilometer (km)meters (m)
centimeters (cm)millimeters (mm)
meters/grams (m/g)British Thermal Unit (BTU)
joules (j)kilogram/meter (kg/m)
X =
CONVERSION FACTORS
186
Technical Information Electronics
ºC ºF– 45.0– 44.4– 43.9– 43.3– 42.8– 42.2– 41.7– 41.1– 40.6– 40.0
– 39.4– 38.9– 38.3– 37.8– 37.2– 36.7– 36.1– 35.6– 35.0– 34.4
– 33.9– 33.3– 32.8– 32.2– 31.7– 31.1– 30.6– 30.0– 29.4– 28.9
– 28.3– 27.8– 27.2– 26.7– 26.1– 25.6– 25.0– 24.4– 23.9– 23.3
– 22.8– 22.2– 21.7– 21.1– 20.6– 20.0– 19.4– 18.9– 18.3– 17.8
– 49.0– 48.0– 47.0– 46.0– 45.0– 44.0– 43.0– 42.0– 41.0– 40.0
– 39.0– 38.0– 37.0– 36.0– 35.0– 34.0– 33.0– 32.0– 31.0– 30.0
– 29.0– 28.0– 27.0– 26.0– 25.0– 24.0– 23.0– 22.0– 21.0– 20.0
– 19.0– 18.0– 17.0– 16.0– 15.0– 14.0– 13.0– 12.0– 11.0– 10.0
– 9.0– 8.0– 7.0– 6.0– 5.0– 4.0– 3.0– 2.0– 1.0
0.0
ºC ºF– 17.2– 16.7– 16.1– 15.6– 15.0– 14.4– 13.9– 13.3– 12.8– 12.2
– 11.7– 11.1– 10.6– 10.0
– 9.4– 8.9– 8.3– 7.8– 7.2– 6.7
– 6.1– 5.6– 5.0– 4.4– 3.9– 3.3– 2.8– 2.2– 1.7– 1.1
– 0.60.00.61.11.72.22.83.33.94.4
5.05.66.16.77.27.88.38.99.4
10.0
1.02.03.04.05.06.07.08.09.0
10.0
11.012.013.014.015.016.017.018.019.020.0
21.022.023.024.025.026.027.028.029.030.0
31.032.033.034.035.036.037.038.039.040.0
41.042.043.044.045.046.047.048.049.050.0
ºC ºF10.611.111.712.212.813.313.914.415.015.6
16.116.717.217.818.318.919.420.020.621.1
21.722.222.823.323.924.425.025.626.126.7
27.227.828.328.929.430.030.631.131.732.2
32.833.333.934.435.035.636.136.737.237.8
51.052.053.054.055.056.057.058.059.060.0
61.062.063.064.065.066.067.068.069.070.0
71.072.073.074.075.076.077.078.079.080.0
81.082.083.084.085.086.087.088.089.090.0
91.092.093.094.095.096.097.098.099.0
100.0
ºC ºF38.338.939.440.040.641.141.742.242.843.3
43.944.445.045.646.146.747.247.848.348.9
49.450.050.651.151.752.252.853.353.954.4
55.055.656.156.757.257.858.358.959.460.0
60.661.161.762.262.863.363.964.465.065.6
101.0102.0103.0104.0105.0106.0107.0108.0109.0110.0
111.0112.0113.0114.0115.0116.0117.0118.0119.0120.0
121.0122.0123.0124.0125.0126.0127.0128.0129.0130.0
131.0132.0133.0134.0135.0136.0137.0138.0139.0140.0
141.0142.0143.0144.0145.0146.0147.0148.0149.0150.0
ºC ºF66.166.767.267.868.368.969.470.070.671.1
71.772.272.873.373.974.475.075.676.176.7
77.277.878.378.979.480.080.681.181.782.2
82.883.383.984.485.085.686.186.787.287.8
88.388.989.490.090.691.191.792.292.893.3
151.0152.0153.0154.0155.0156.0157.0158.0159.0160.0
161.0162.0163.0164.0165.0166.0167.0168.0169.0170.0
171.0172.0173.0174.0175.0176.0177.0178.0179.0180.0
181.0182.0183.0184.0185.0186.0187.0188.0189.0190.0
191.0192.0193.0194.0195.0196.0197.0198.0199.0200.0
Temperature Conversion Chart
To use this chart, find your known temperature (°F) in the shaded column.
TEMPERATURE CONVERSION FORMULAE
°F = 9 C+325°C= 5 (°F–32)9
187
Electronics Technical Information
Conduit Trade Size
I.D. Inches
Internal Area, In2
1 Conductor (53% fill)
2 Conductors (31% fill)
Conductors (40% fill)
Cable Area In2
0.008
0.012
0.018
0.024
0.031
0.040
0.049
0.059
0.071
0.083
0.096
0.110
0.126
0.142
0.159
0.177
0.196
0.216
0.238
0.260
0.283
0.307
0.332
0.358
0.385
0.413
0.442
0.472
0.503
0.535
0.567
0.601
0.636
0.672
0.709
0.747
0.785
0.825
0.866
0.908
Notice: 1. The reader is cautioned to consult the 2002 NEC for specific information regarding conduit fill.2. This Conduit Capacity Chart should only be used as a guide when attempting to estimate conduit fill.3. For additional information, the reader should refer to the 2002 National Electrical Code, Chapter 9.
15
9
6
5
3
3
1
1
1
1
1
1
1
1
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
26
17
11
8
6
5
4
3
2
1
1
1
1
1
1
1
1
1
1
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
43
27
19
14
10
8
6
5
4
4
3
3
2
1
1
1
1
1
1
1
1
1
1
1
1
1
1
0
0
0
0
0
0
0
0
0
0
0
0
0
76
48
33
24
19
15
12
10
8
7
6
5
4
4
3
3
3
2
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
0
0
0
104
66
46
34
26
20
16
13
11
9
8
7
6
5
5
4
4
3
3
3
2
2
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
170
109
75
55
42
33
27
22
18
16
13
12
10
9
8
7
6
6
5
5
4
4
4
3
3
3
3
2
2
1
1
1
1
1
1
1
1
1
1
1
244
156
108
79
81
48
39
32
27
23
19
17
15
13
12
10
9
8
8
7
6
6
5
5
5
4
4
4
3
3
3
3
3
2
2
1
1
1
1
1
375
240
166
122
93
74
60
49
41
35
30
26
23
20
18
17
15
13
12
11
10
9
8
8
7
7
6
6
5
5
5
4
4
4
4
3
3
3
3
3
504
322
224
164
126
99
80
66
56
47
41
35
31
27
24
22
20
18
16
15
14
12
11
11
10
9
8
8
7
7
6
6
6
5
5
5
5
4
4
4
648
414
288
211
162
128
103
85
72
61
52
46
40
35
32
28
25
23
21
19
18
16
15
14
13
12
11
10
10
9
8
8
8
7
7
6
6
6
5
5
1/2
0.622
0.304
0.161
0.094
0.122
3/4
0.824
0.533
0.283
0.165
0.213
1
1.049
0.864
0.458
0.268
0.346
1-1/4
1.380
1.496
0.793
0.464
0.598
1-1/2
1.610
2.036
1.079
0.631
0.814
2
2.067
3.356
1.778
1.040
1.342
2-1/2
2.731
5.858
3.105
1.816
2.343
3
3.356
8.846
4.688
2.742
3.538
3-1/2
3.834
11.545
6.119
3.579
4.618
4
4.334
14.753
7.819
4.573
5.901
Conduit Capacity Chart
Numbers listed below are based on the 2002 NEC (40% fill) for 3 or more non-lead covered cables.Cable ODInches
0.100
0.125
0.150
0.175
0.200
0.225
0.250
0.275
0.300
0.325
0.350
0.375
0.400
0.425
0.450
0.475
0.500
0.525
0.550
0.575
0.600
0.625
0.650
0.675
0.700
0.725
0.750
0.775
0.800
0.825
0.850
0.875
0.900
0.925
0.950
0.975
1.000
1.025
1.050
1.075
188
Technical Information Electronics
RG 6/UC3521 CPMC-68-36 -- -- RFB-1707-Q1 105-1516-9C3523 CPMC-68-36 302-510CS -- -- 105-1516-9C3524 CPMC-68-36 302-510CS -- -- 105-1516-9C3525 CPMC-68-36 -- -- -- 105-1516-9C5760 CPMC-68-45 -- -- RFB-1707-Q1 105-1516-9C5761 CPMC-68-45 302-5CSQS SNS6BNC -- UPL20-34C5774 CPMC-68-45 -- SNS6BNC -- 105-1153-9C5775 CPMC-68-45 302-5CSQS SNS6BNC -- 105-1153-9C5776 CPMC-68-45 -- SNS6BNC -- 105-1153-9C5777 CPMC-68-45 -- SNS6BNC RFB-1707-Q 105-1153-9C5778 CPMC-68-45 -- SNS6BNC RFB-1707-Q 105-1153-9C5785 CPFI-UG88-3 (TWIST ON) 302-5CSQS SNS6QSBNC -- UPL20-41C5802 CPMC-68-45 -- SNS6BNC RFB-1707-Q UPL20-41C5804 CPMC-68-45 -- SNS6BNC RFB-1707-Q UPL20-41C5810 CPMC-68-5 -- -- -- UPL20-51C5812 CPMC-68-45 -- -- -- UPL20-41C5814 CPMC-68-45 302-5CSQS SNS6BNC RFB-1707-Q UPL20-41C5822 CPMC-68-45 302-5CSQS SNS6BNC RFB-1707-Q UPL20-41C5824 CPMC-68-45 302-5CSQS SNS6BNC RFB-1707-Q UPL20-41C5826 CPMC-68-45 302-5CSQS SNS6BNC RFB-1707-Q UPL20-41C5886 CPMC-68-45 -- SNS6BNC RFB-1707-Q 105-1153-9C5888 CPMC-68-45 -- SNS6BNC -- 105-1153-9C5889 CPFI-UG88-3 (TWIST ON) 302-5CSQS SNS6QSBNC -- UPL20-41C5890 CPMC-68-45 -- SNS6BNC RFB-1707-Q UPL20-41C8029 CPMC-68-45 302-5CS SNS6BNC RFB-1707-Q UPL20-41C8031 CPMC-68-36 -- -- RFB-1707-Q1 105-1516-9
CATALOG NUMBER BNC CRIMP PLUG BNC COMPRESSION PLUG SNAP-N-SEAL BNC BNC CRIMP PLUG BNC CRIMP PLUG
CAMBRIDGE GEM LRC RF INDUSTRIES TROMPETER
RG 8/UC1108 -- CPMC-88-17 305-17 -- RFB-1107-1X PL20-52C1154 2-225295-1 -- -- KC-59-577 M06 RFB-1101-1EN PL20-6AC1180 -- -- -- KC-59-642 M06 RFB-1101-1EN N/AC1197 -- -- -- -- RFB-1101-1SI PL20-6AC1198 -- -- -- -- RFB-1101-1SI PL20-6A
CATALOG NUMBER BNC PLUG BNC CRIMP PLUG BNC CRIMP PLUG BNC CRIMP PLUG BNC PLUG BNC CRIMP PLUG
AMP CAMBRIDGE GEM KINGS ELECTRONICS RF INDUSTRIES TROMPETER
RG 7/UC5851 PL20-48C5853 105-1677-1C5856 PL20-48C5857 PL20-48
CATALOG NUMBER BNC CRIMP PLUG
TROMPETER
Coax Connector Cross Reference
BNC TYPE CONNECTORS
RG 11/UC1160 CPMC-88-26 305-26 RFB-1707-R1 UPL20-6AC3528 CPMC-88-27 -- -- UPL20-6AC3529 CPMC-88-28 -- -- UPL20-6AC5011 CPMC-88-29 -- RFB-1707-R UPL20-6AC5025 CPMC-88-30 -- RFB-1707-R UPL20-6AC5027 -- -- -- --C5029 CPMC-88-30 -- RFB-1707-R UPL20-6AC5033 CPMC-88-31 -- RFB-1707-R UPL20-6AC5034 CPMC-88-32 -- RFB-1707-R UPL20-6AC5039 CPMC-88-33 -- RFB-1707-R UPL20-6AC5041 CPMC-88-34 -- RFB-1707-R UPL20-6AC5043 CPMC-88-35 -- RFB-1707-R UPL20-6AC5044 CPMC-88-36 -- RFB-1707-R UPL20-6A
CATALOG NUMBER BNC CRIMP PLUG BNC CRIMP PLUG BNC CRIMP PLUG BNC CRIMP PLUG
CAMBRIDGE GEM RF INDUSTRIES TROMPETER
189
Electronics Technical Information
Coax Connector Cross Reference
BNC TYPE CONNECTORS
RG 58/UC1117 22709-5 CPMC-88-1 305-1 IA-3620 755-115-5 RFB-1106-2 PL20-1C1155 22709-5 CPMC-88-1 305-1 IA-3620 755-115-5 RFB-1106-2 PL20-1C1166 22709-5 CPMC-88-1 305-1 IA-3620 755-115-5 RFB-1106-2 PL20-1C1178 22709-5 CPMC-88-1 305-1 IA-3620 755-115-5 RFB-1106-2 PL20-1C1188 22709-5 CPMC-88-1 305-1 IA-3620 -- RFB-1106-2 PL20-1C3519 6-22709-8 CPMC-88-11 305-11 -- -- RFB-1707-7 PL20-4C3579 6-22709-8 CPMC-88-11 305-11 IA-3623 -- RFB-1707-7 PL20-4C5045 22709-5 CP-88-10 (TWIST ON) -- IA-3620 755-114-5 RFB-1106-2 PL20-1C5779 6-22709-8 CPMC-88-1 305-1 -- -- -- 105-1598-1
CATALOG NUMBER BNC PLUG BNC CRIMP PLUG BNC CRIMP PLUG BNC PLUG BNC CRIMP PLUG BNC CRIMP PLUG BNC CRIMP PLUG
AMP CAMBRIDGE GEM IDEAL KINGS ELECTRONICS RF INDUSTRIES TROMPETER
RG 59/UC1102 -- CPMC-78-2 307-2 (Crimp) -- SNS59BNC RFB-1707-D1 UPL20-2C1103 -- CPMC-78-2 302-2CS -- -- RFB-1707-D1 UPL20-2C1104 -- CPMC-78-2 307-2 (Crimp) -- SNS59BNC RFB-1707-D UPL20-2C1106 -- CPMC-78-2 307-2 (Crimp) -- SNS59BNC RFB-1707-D UPL20-2C1107 -- CPMC-68-35 302-2CS -- SNS59BNC -- UPL20-2C1110 -- CPMC-78-2 307-2 (Crimp) -- SNS59BNC RFB-1707-D UPL20-2C1112 -- CPMC-78-2 307-2 (Crimp) -- SNS59BNC RFB-1707-D UPL20-2C1135 -- CPMC-78-2 307-2 (Crimp) -- SNS59BNC RFB-1707-D UPL20-2C1142 -- CPMC-68-35 302-2CS -- SNS59BNC RFB-1707-W UPL20-2AC1158 -- CPMC-78-18 307-18 (Crimp) -- -- -- UPL20-22C3500 -- CPMC-68-35 302-10CS -- -- -- 105-1287-9C3526 -- CPMC-68-50 -- -- -- -- 105-1184-9C3527 -- CPMC-68-35 -- -- -- -- UPL20-53C5770 -- CPMC-68-35 302-2CS -- -- RFB-1707-W UPL20-2AC5780 -- CPMC-68-35 302-2CS -- SNS59BNC RFB-1707-W UPL20-2AC5782 -- CPMC-68-35 302-2CS -- SNS59BNC RFB-1707-W UPL20-2AC5784 -- CP-88-4 (TWIST ON) -- -- -- -- 105-1558-9C5816 -- CPMC-78-3 -- -- -- -- UPL20-6C5830 -- CPMC-78-2 307-2 (Crimp) -- SNS59BNC RFB-1707-D1 UPL20-2C5831 -- CPMC-78-2 307-2 (Crimp) -- SNS59BNC RFB-1707-D1 UPL20-2C5832 -- CPMC-68-35 302-2CS -- SNS59BNC RFB-1707-D1 UPL20-2AC5834 -- CPMC-78-2 307-2 (Crimp) -- SNS59BNC RFB-1707-D1 UPL20-2C5836 -- CPMC-78-2 307-2 (Crimp) -- SNS59BNC RFB-1707-D UPL20-2C5838 22185-5 CPMC-78-3 -- 2065--6--9 -- RFB-1708 UPL20-6C5842 -- CPMC-78-2 307-2 (Crimp) -- SNS59BNC -- UPL20-2C5844 -- CPMC-78-2 307-2 (Crimp) -- SNS59BNC RFB-1707-D UPL20-2C8005 -- CPMC-78-2 307-2 (Crimp) -- SNS59BNC RFB-1707-D UPL20-2C8025 -- CPMC-78-2 302-10CS -- -- RFB-1707-D UPL20-2C8027 -- CPMC-78-2 302-10CS -- -- -- UPL20-2C8028 -- CPMC-78-2 307-2 (Crimp) -- SNS59BNC -- UPL20-2C8030 -- CPMC-68-10 -- -- -- RFB-1707-D3 105-1287-9
CATALOG NUMBER BNC PLUG BNC CRIMP PLUG BNC COMPRESSION PLUG BNC CRIMP PLUG SNAP-N-SEAL BNC BNC CRIMP PLUG BNC CRIMP PLUG
AMP CAMBRIDGE GEM KINGS ELECTRONICS LRC RF INDUSTRIES TROMPETER
RG 174/UC1156 1-22709-6 CPMC-88-19 305-19 KC-59-557 M06 RFB-1106-5 PL20-5
CATALOG NUMBER BNC PLUG BNC CRIMP PLUG BNC CRIMP PLUG BNC CRIMP PLUG BNC CRIMP PLUG BNC CRIMP PLUG
AMP CAMBRIDGE GEM KINGS ELECTRONICS RF INDUSTRIES TROMPETER
RG 62/UC1162 22709-7 CPMC-78-2 307-2 755-155-5 UPL20-2C1164 22709-7 CPMC-78-2 307-3 755-115-5 UPL20-2C3520 4-22709-9 CPMC-68-2 -- -- 105-1287-1
CATALOG NUMBER BNC PLUG BNC CRIMP PLUG BNC CRIMP PLUG BNC CRIMP PLUG BNC CRIMP PLUG
AMP CAMBRIDGE GEM KINGS ELECTRONICS TROMPETER
RG 213/UC1176 2-225395-1 CPMC-88-26 305-26 RFB-1101-1SI PL20-6A
CATALOG NUMBER BNC PLUG BNC CRIMP PLUG BNC CRIMP PLUG BNC CLAMP PLUG BNC CLAMP PLUG
AMP CAMBRIDGE GEM RF INDUSTRIES TROMPETER
190
Technical Information Electronics
Coax Connector Cross Reference
RG 6/UC3521 CPF-56-ALM 0406-4 (Crimp) GF-6-AHS/USA Contact Gilbert --C3523 CPF-56-ALM 0406-610CS NS-8101-15 Contact Gilbert --C3524 CPF-56-ALM 0406-610CS Contact Gilbert Contact Gilbert --C3525 CPF-56-ALM 0406-4 (Crimp) Contact Gilbert Contact Gilbert --C5760 CPF-56-ALM 0406-4 (Crimp) GF-6-AHS/USA GF-UR-6 --C5761 CPF-56-ALM 0406-6CSQS GF-6-AHS/USA GF-UR-6 85-037C5774 CPF-56-ALM 0406-4 (Crimp) GF-6-AHS/USA GF-UR-6 85-037C5775 CPF-56-ALM 0406-6CSQS GF-6-AHS/USA GF-UR-6 85-037C5776 CPF-56-ALM 0406-4 (Crimp) GF-6-AHS/USA GF-UR-6 85-037C5777 CPF-56-ALM 0406-4 (Crimp) GF-6-AHS/USA GF-UR-6 85-037C5778 CPF-56-ALM 0406-4 (Crimp) GF-6-AHS/USA GF-UR-6 --C5785 CPF-56-ALS 0406-6CSQS GF-6-AHS/USA GF-UR-6 85-057C5802 CPF-56-ALM 0406-4 (Crimp) GF-6-AHS/USA GF-UR-6 85-037C5804 CPF-56-ALMWP -- GF-6-AHS/USA GF-UR-6 85-037C5810 CPF-56-ALS -- Contact Gilbert Contact Gilbert --C5812 CPF-56-ALX -- GF-6-AHS/USA GF-UR-6 85-037C5814 CPF-56-ALM 0406-6CSQS GF-6-AHS/USA GF-UR-6 85-037C5822 CPF-56-ALM 0406-6CSQS GF-6-AHS/USA GF-UR-6 85-037C5824 CPF-56-ALM 0406-6CSQS GF-6-AHS/USA GF-UR-6 85-037C5826 CPF-56-ALM 0406-4 (Crimp) GF-6-AHS/USA GF-UR-6 85-037C5886 CPF-56-ALM 0406-4 (Crimp) GF-6-AHS/USA GF-UR-6 85-037C5888 CPF-56-ALM 0406-4 (Crimp) GF-6-AHS/USA GF-UR-6 85-037C5889 CPF-56-ALS 0406-6CSQS GF-6-AHS/USA GF-UR-6 85-057C5890 CPF-56-ALM 0406-4 (Crimp) GF-6-AHS/USA GF-UR-6 --C8029 CPF-56-ALM 0406-6CS Contact Gilbert Contact Gilbert --C8031 CPF-56-ALM 0406-4 (Crimp) Contact Gilbert Contact Gilbert --
CATALOG NUMBER F-TYPE CRIMP F-TYPE COMPRESSION F-TYPE CRIMP F-TYPE COMPRESSION F-TYPE
CAMBRIDGE GEM GILBERT IDEAL INDUSTRIES
F-TYPE CONNECTORS
RG 6/U (cont.)C3521 -- -- CFS 6 PL -- EX6P or EX6XLP --C3523 -- -- CFS 6 PL -- EX6P or EX6XLP --C3524 -- -- CFS 6 PL -- EX6P or EX6XLP --C3525 -- -- -- -- -- --C5760 -- -- CFS 6 U (SU) CFS 6 UV (SUV) EX6 or EX6XLP --C5761 AMF6 SNS6 CFS 6 U (SU) CFS 6 UV (SUV) EX6 or EX6XLP PL130SC-020C5774 AMF6 SNS6 CFS 6 U (SU) CFS 6 UV (SUV) EX6 or EX6XLP PL130SC-020C5775 AMF6 SNS6 CFS 6 U (SU) CFS 6 UV (SUV) EX6 or EX6XLP --C5776 AMF6 SNS6 CFS 6 U (SU) CFS 6 UV (SUV) EX6 or EX6XLP PL130SC-020C5777 AMF6 SNS6 CFS 6 U (SU) CFS 6 UV (SUV) EX6 or EX6XLP PL130SC-020C5778 AMF6 SNS6 CFS 6 U (SU) CFS 6 UV (SUV) EX6 or EX6XLP PL130SC-020C5785 AMF6 SNS6QS CFS 6 U (SU) CFS 6 UV (SUV) EX6 or EX6XLP --C5802 AMF6 SNS6 CFS 6 U (SU) CFS 6 UV (SUV) EX6 or EX6XLP PL130SC-020C5804 AMF6 SNS6 CFS 6 U (SU) CFS 6 UV (SUV) EX6 or EX6XLP PL130SC-020C5810 -- -- -- -- -- PL130SC-017C5812 -- -- CFS 6 U (SU) CFS 6 UV (SUV) EX6 or EX6XLP --C5814 AMF6 SNS6 CFS 6 U (SU) CFS 6 UV (SUV) EX6 or EX6XLP PL130SC-020C5822 AMF6 SNS6 CFS 6 U (SU) CFS 6 UV (SUV) EX6 or EX6XLP PL130SC-020C5824 AMF6 SNS6 CFS 6 U (SU) CFS 6 UV (SUV) EX6 or EX6XLP PL130SC-020C5826 AMF6 SNS6 CFS 6 U (SU) CFS 6 UV (SUV) EX6 or EX6XLP PL130SC-020C5886 AMF6 SNS6 CFS 6 U (SU) CFS 6 UV (SUV) EX6 or EX6XLP --C5888 AMF6 SNS6 CFS 6 U (SU) CFS 6 UV (SUV) EX6 or EX6XLP PL130SC-020C5889 AMF6 SNS6QS -- -- -- --C5890 AMF6 SNS6 -- -- -- PL130SC-020C8029 AMF6 SNS6 -- -- -- PL130SC-020C8031 -- -- -- -- -- --
U SERIES UV SERIESCATALOG NUMBER F-TYPE CRIMP SNAP-N-SEAL U-INDOOR UV-INDOOR
EXF-TYPE CRIMP
SU-OUTDOOR SUV INDOOR/OUTDOORINDOOR/OUTDOOR
LRC PPC TROMPETER
191
Electronics Technical Information
Coax Connector Cross Reference
RG 7/UC5851 GAF-236/051-AHS/368 GAF-UST-7 AMF7 SNS7B CFS 7 U (SU) CFS 7 PNU (PNSU) EX 7C5853 GAF-236/051-AHS/368 GAF-UST-7 -- -- CFS 7 U (SU) CFS 7 PNU (PNSU) EX 7C5856 GAF-236/051-AHS/368 GAF-UST-7 -- -- CFS 7 U (SU) CFS 7 PNU (PNSU) EX 7C5857 GAF-236/051-AHS/398 GAF-UST-7Q -- -- CFS 7 U (SU) CFS 7 PNU (PNSU) --
U SERIES PNU SERIES
CATALOG NUMBER F-TYPE CRIMP F-TYPE F-TYPE CRIMP SNAP-N-SEAL U-INDOOR PNU-INDOOR EXCOMPRESSION SU-OUTDOOR PNSU INDOOR/ INDOOR/OUTDOOR
OUTDOOR
GILBERT LRC PPC
F-TYPE CONNECTORS
RG 11/UC1160 CPF-11-ALM Contact Gilbert Contact Gilbert -- -- -- -- --C3528 CPF-11-ALM Contact Gilbert Contact Gilbert -- -- -- -- --C3529 CPF-11-ALM Contact Gilbert Contact Gilbert -- -- -- -- --C5011 CPF-11-ALM GF-11-AHS/460 GAF-UST-11 AMF11 SNS11AS CFS 11 U (SU) CFS 11 PNU (PNSU) EX 11C5025 CPF-11-ALM Contact Gilbert Contact Gilbert -- -- CFS 11 U (SU) CFS 11 PNU (PNSU) EX 11C5027 -- Contact Gilbert Contact Gilbert -- -- -- -- --C5029 CPF-11-ALM GF-11-AHS/460 GAF-UST-11 AMF11 SNS11AS CFS 11 U (SU) CFS 11 PNU (PNSU) EX 11C5033 CPF-11-ALM GF-11-AHS/460 GAF-UST-11 AMF11 SNS11AS CFS 11 U (SU) CFS 11 PNU (PNSU) EX 11C5034 CPF-11-ALM GF-11-AHS/460 GAF-UST-11 AMF11 SNS11AS CFS 11 U (SU) CFS 11 PNU (PNSU) EX 11C5039 CPF-11-ALM GF-11-AHS/460 GAF-UST-11 AMF11 SNS11AS CFS 11 U (SU) CFS 11 PNU (PNSU) EX 11C5041 CPF-11-ALM GF-11-AHS/460 GAF-UST-11 AMF11 SNS11AS CFS 11 U (SU) CFS 11 PNU (PNSU) EX 11C5043 CPF-11-ALM GF-11-AHS/460 GAF-UST-11 AMF11 SNS11AS CFS 11 U (SU) CFS 11 PNU (PNSU) EX 11C5044 -- GF-11-AHS/480 GAF-UST-11Q AMF11 SNS11AS CFS 11 U (SU) CFS 11 PNU (PNSU) EX 11
U SERIES UV SERIESCATALOG NUMBER F-TYPE CRIMP F-TYPE CRIMP F-TYPE F-TYPE CRIMP SNAP-N-SEAL U-INDOOR UV-INDOOR EX
COMPRESSION SU-OUTDOOR SUV INDOOR/ INDOOR/OUTDOOROUTDOOR
CAMBRIDGE GILBERT LRC PPC
RG 59/UC1102 CPF-59-ALM 0459-2M (Crimp) GF-59-AHS/USA GF-UR-59 85-036 AMF59 SNS59C1103 CPF-59-ALM 0459-2CS GF-59-AHS/USA GF-UR-59 85-036 -- --C1104 CPF-59-ALM 0459-2M (Crimp) GF-59-AHS/USA GF-UR-59 85-036 AMF59 SNS59C1106 CPF-59-ALM 0459-2M (Crimp) GF-59-AHS/USA GF-UR-59 85-036 AMF59 SNS59C1107 CPF-59-ALM 0459-2M (Crimp) GF-59-AHS/USA GF-UR-59 85-036 AMF59 SNS59C1110 CPF-59-ALM 0459-2M (Crimp) GF-59-AHS/USA GF-UR-59 85-036 AMF59 SNS59C1112 CPF-59-ALM 0459-2M (Crimp) GF-59-AHS/USA GF-UR-59 85-036 AMF59 SNS59C1135 CPF-59-ALM 0459-2M (Crimp) GF-59-AHS/USA GF-UR-59 85-036 AMF59 SNS59C1142 CPF-59-ALM 0459-2CS GF-59-AHS/USA GF-UR-59 85-036 AMF59 SNS59C1158 -- -- GF-1097-17 Contact Gilbert -- -- --C3500 -- 0459-10CS Contact Gilbert Contact Gilbert -- -- --C3526 -- -- Contact Gilbert Contact Gilbert -- -- --C3527 CPF-59-ALM 0459-2M (Crimp) Contact Gilbert Contact Gilbert -- -- --C5770 CPF-59-ALM 0459-2CS Contact Gilbert Contact Gilbert 85-036 -- --C5780 CPF-59-ALM 0459-2M (Crimp) GF-59-AHS/USA GF-UR-59 85-036 AMF59 SNS59C5782 CPF-59-ALM 0459-2M (Crimp) GF-59-AHS/USA GF-UR-59 85-036 AMF59 SNS59C5784 -- -- GF-59-AHS/357 Contact Gilbert 85-059 -- SNS59QSC5816 -- -- Contact Gilbert Contact Gilbert -- -- --C5830 CPF-59-ALM 0459-2M (Crimp) GF-59-AHS/USA GF-UR-59 85-036 AMF59 SNS59C5831 CPF-59-ALM 0459-2M (Crimp) GF-59-AHS/USA GF-UR-59 85-036 AMF59 SNS59C5832 CPF-59-ALM 0459-2M (Crimp) GF-59-AHS/USA GF-UR-59 85-036 AMF59 SNS59C5834 CPF-59-ALM 0459-2M (Crimp) GF-59-AHS/USA GF-UR-59 85-036 AMF59 SNS59C5836 CPF-59-ALM 0459-2M (Crimp) GF-59-AHS/USA GF-UR-59 85-036 AMF59 SNS59C5838 -- -- Contact Gilbert Contact Gilbert -- -- --C5842 CPF-59-ALM 0459-2M (Crimp) GF-59-AHS/USA GF-UR-59 85-036 AMF59 SNS59C5844 CPF-59-ALM 0459-2M (Crimp) GF-59-AHS/USA GF-UR-59 -- AMF59 SNS59C8005 CPF-59-ALM 0459-2M (Crimp) Contact Gilbert Contact Gilbert -- AMF59 SNS59C8025 CPF-59-ALM 0459-10CS Contact Gilbert Contact Gilbert -- -- --C8027 CPF-59-ALM 0459-10CS Contact Gilbert Contact Gilbert -- -- --C8028 CPF-59-ALM 0459-2M (Crimp) Contact Gilbert Contact Gilbert -- AMF59 SNS59C8030 CPF-59-ALM 0459-2M (Crimp) Contact Gilbert Contact Gilbert -- -- --
CATALOG NUMBER F-TYPE CRIMP F-TYPE COMPRESSION F-TYPE CRIMP F-TYPE COMPRESSION F-TYPE F-TYPE CRIMP SNAP-N-SEAL
CAMBRIDGE GEM GILBERT IDEAL INDUSTRIES LRC
192
Technical Information Electronics
Coax Connector Cross Reference
F-TYPE CONNECTORS
RG 59/U (cont.)C1102 CFS 59 U (SU) CFS 59 UV (SUV) EX59 or EX59XL PL130SC-014C1103 CFS 59 U (SU) CFS 59 UV (SUV) EX59 or EX59XL PL130SC-013C1104 CFS 59 U (SU) CFS 59 UV (SUV) EX59 or EX59XL PL130SC-013C1106 CFS 59 U (SU) CFS 59 UV (SUV) EX59 or EX59XL PL130SC-013C1107 CFS 59 U (SU) CFS 59 UV (SUV) EX59 or EX59XL PL130SC-013C1110 CFS 59 U (SU) CFS 59 UV (SUV) EX59 or EX59XL PL130SC-013C1112 CFS 59 U (SU) CFS 59 UV (SUV) EX59 or EX59XL PL130SC-013C1135 CFS 59 U (SU) CFS 59 UV (SUV) EX59 or EX59XL PL130SC-013C1142 CFS 59 U (SU) CFS 59 UV (SUV) EX59 or EX59XL PL130SC-023C1158 -- -- -- PL130SC-008C3500 -- -- -- --C3526 -- -- -- --C3527 CFS 59 U (SU) CFS 59 UV (SUV) EX59 or EX59XL PL130SC-023C5770 CFS 59 U (SU) CFS 59 UV (SUV) EX59 or EX59XL PL130SC-022C5780 CFS 59 U (SU) CFS 59 UV (SUV) EX59 or EX59XL PL130SC-023C5782 CFS 59 U (SU) CFS 59 UV (SUV) EX59 or EX59XL PL130SC-023C5784 CFS 59 U (SU) CFS 59 UV (SUV) EX59 or EX59XL --C5816 CFS 6 JU (SU) CFS 6 JUV (SUV) EX59 or EX59XL PL130SC-016C5830 CFS 59 U (SU) CFS 59 UV (SUV) EX59 or EX59XL PL130SC-013AC5831 CFS 59 U (SU) CFS 59 UV (SUV) EX59 or EX59XL PL130SC-013AC5832 CFS 59 U (SU) CFS 59 UV (SUV) EX59 or EX59XL PL130SC-013AC5834 CFS 59 U (SU) CFS 59 UV (SUV) EX59 or EX59XL PL130SC-013AC5836 CFS 59 U (SU) CFS 59 UV (SUV) EX59 or EX59XL PL130SC-013C5838 -- -- -- PL130SC-016C5842 CFS 59 U (SU) CFS 59 UV (SUV) EX59 or EX59XL PL130SC-013C5844 CFS 59 U (SU) CFS 59 UV (SUV) EX59 or EX59XL PL130SC-013C8005 CFS 59 U (SU) CFS 59 UV (SUV) EX59 or EX59XL PL130SC-013C8025 -- -- -- PL130SC-013C8027 -- -- -- PL130SC-013C8028 -- -- -- PL130SC-013AC8030 -- -- -- --
U SERIES UV SERIES
CATALOG NUMBER U-INDOOR UV-INDOOR EX F-TYPE CRIMPSU-OUTDOOR SUV INDOOR/ INDOOR/OUTDOOR
OUTDOOR
PPC TROMPETER
RG 62/UC1162 PL130SC-013C1164 PL130SC-013C3520 -
CATALOG NUMBER F-TYPE CRIMP
TROMPETER
RG 174/UC1156 PL130SC-004
CATALOG NUMBER F-TYPE CRIMP
TROMPETER
193
Electronics Technical Information
Coax Connector Cross Reference
N-TYPE CONNECTORS
RG 6/UC3521 --C3523 --C3524 --C3525 --C5760 --C5761 UPL95-34C5774 --C5775 --C5776 --C5777 --C5778 --C5785 --C5802 --C5804 --C5810 UPL95-51C5812 UPL95-41C5814 --C5822 UPL95-41C5824 UPL95-41C5826 UPL95-41C5886 --C5888 --C5889 UPL95-41C5890 UPL95-41C8029 UPL95-41C8031 --
CATALOG NUMBER N-TYPE CRIMP PLUG
TROMPETER
RG 7/UC5851 PL95-48C5853 N/AC5856 PL95-48C5857 PL95-48
CATALOG NUMBER N-TYPE CRIMP PLUG
TROMPETER
RG 8/UC1108 -- -- -- -- RFN-1007-2SX --
C1154 225661-2 (Mil) CPN-68-8 KN-59-176 -- RFN-1006-3E PL95-6A415232-6 RFN-1006-3E
C1180 -- CPN-8/110 1205-4-9 NM8HB10 RFN-1006-3I --
C1198 1-225661-6 (Mil) CPN-68-8 1205-4-9 -- RFN-1006-3I PL95-6A414160-4
CATALOG NUMBER N-TYPE PLUG N-TYPE CRIMP PLUG N-TYPE CRIMP PLUG N-TYPE PLUG N-TYPE CRIMP PLUG N-TYPE PLUG
AMP CAMBRIDGE KINGS ELECTRONICS LRC RF INDUSTRIES TROMPETER
RG 11/UC1160 CPN-8 UPL95-6AC3528 CPN-8 UPL95-6AC3529 CPN-8 UPL95-6AC5011 CPN-8 UPL95-6AC5025 CPN-68-8 UPL95-6AC5027 -- --C5029 CPN-8 UPL95-6AC5033 CPN-8 UPL95-6AC5034 CPN-8 UPL95-6AC5039 CPN-8 UPL95-6AC5041 CPN-8 UPL95-6AC5043 CPN-8 UPL95-6AC5044 CPN-68-8 UPL95-6A
CATALOG NUMBER N-TYPE CRIMP PLUG N-TYPE CRIMP PLUG
CAMBRIDGE TROMPETER
194
Technical Information Electronics
N-TYPE CONNECTORS
RG 58/UC1117 1-225661-2 (Mil) CPN-68-1 1205-19-5 RFN-1005-3C PL95-1
415232-2
C1155 1-225661-2 (Mil) CPN-68-1 1205-19-5 RFN-1005-3C PL95-1415232-2
C1166 1-225661-2 (Mil) CPN-68-1 1205-19-5 RFN-1005-3C PL95-1415232-2
C1178 1-225661-2 (Mil) CPN-68-1 1205-19-5 RFN-1005-3C PL95-1415232-2
C1188 1-225661-2 (Mil) CPN-68-1 -- RFN-1005-3C PL95-1415232-2
C3519 -- CPN-1 -- -- PL95-4C3579 -- CPN-1 -- -- PL95-4
C5045 1-225661-2 (Mil) CPN-68-1 -- RFN-1005-3C PL95-1415232-2
C5779 -- CPN-1 -- -- --
CATALOG NUMBER N-TYPE PLUG N-TYPE CRIMP PLUG N-TYPE CRIMP PLUG N-TYPE CRIMP PLUG N-TYPE CRIMP PLUG
AMP CAMBRIDGE KING ELECTRONICS RF INDUSTRIES TROMPETER
RG 59/UC1102 -- -- -- RFN-1907-2S UPL95-2C1103 -- CPN-2 400-2 RFN-1907-2S UPL95-2C1104 -- CPN-2 400-2 RFN-1907-2S UPL95-2C1106 -- CPN-2 400-2 RFN-1907-2S UPL95-2C1107 -- CPN-2 400-2 -- UPL95-2C1110 -- CPN-2 400-2 RFN-1907-2S UPL95-2C1112 -- CPN-2 400-2 RFN-1907-2S UPL95-2C1135 -- CPN-2 400-2 RFN-1907-2S UPL95-2C1142 -- -- -- -- UPL95-2AC1158 -- -- -- -- UPL95-22C3500 -- -- -- -- --C3526 -- -- -- -- --C3527 -- -- -- -- --C5770 -- -- -- -- UPL95-2AC5780 -- -- -- -- UPL95-2AC5782 -- -- -- -- UPL95-2AC5784 -- -- -- -- --C5816 -- -- -- -- UPL95-6C5830 -- -- -- RFN-1907-2S UPL95-2C5831 -- -- -- RFN-1907-2S UPL95-2C5832 -- -- -- -- UPL95-2AC5834 -- -- -- -- UPL95-2C5836 -- CPN-2 400-2 -- UPL95-2C5838 -- -- -- RFN-1907-2S UPL95-6C5842 -- -- -- -- UPL95-2C5844 -- -- -- RFN-1907-2S UPL95-2C8005 -- CPN-2 400-2 -- UPL95-2C8025 -- CPN-2 400-2 -- UPL95-2C8027 -- CPN-2 400-2 -- UPL95-2C8028 -- -- -- -- UPL95-2C8030 -- -- -- -- --
CATALOG NUMBER N-TYPE PLUG N-TYPE CRIMP PLUG N-TYPE CRIMP PLUG N-TYPE CRIMP PLUG N-TYPE CRIMP PLUG
AMP CAMBRIDGE GEM RF INDUSTRIES TROMPETER
Coax Connector Cross Reference
195
Electronics Technical Information
Coax Connector Cross Reference
RG 62/UC1162 -- CPN-2 400-2 UPL95-2C1164 -- CPN-2 400-2 UPL95-2C3520 -- -- -- --
CATALOG NUMBER N-TYPE PLUG N-TYPE CRIMP PLUG N-TYPE CRIMP PLUG N-TYPE PLUG
AMP CAMBRIDGE GEM TROMPETER
N-TYPE CONNECTORS
RG 174/UC1156 -- RFN-1005-B-03 PL95-5
CATALOG NUMBER N-TYPE PLUG N-TYPE PLUG N-TYPE PLUG
AMP RF INDUSTRIES TROMPETER
RG 213/UC1176 1-227086-0 (Mil) CPN-68-8 KN-59-202 RFN-1006-3I PL95-6A
415232-6
CATALOG NUMBER N-TYPE PLUG N-TYPE CRIMP PLUG N-TYPE CRIMP PLUG N-TYPE PLUG N-TYPE PLUG
AMP CAMBRIDGE KINGS ELECTRONICS RF INDUSTRIES TROMPETER
196
Technical Information Electronics
COPPER CONDUCTOR DATAThe conductors used by General Cable meet the applicable requirements of ASTM specifications B-3, B-33, B-172, B-173, B-174 and B-286 andFederal Specification QQ-W-343.
The following data covers the more commonly used conductor constructions in the electrical and electronics industry. Special constructions, notshown, are available or can be designed to meet specific requirements. It is suggested that the General Cable Product Engineering Department becontacted before a specification is finalized.
D.C. RESISTANCE 20°C(2)
AWG STRANDINGTYPE
STRANDING(1)DIAMETER(4) AREA WEIGHT BARE OF SILVER COATING BREAK STR.
LBS.TIN COATING(3)
AWG Conductor Chart
Co or Bu–Bu–Co–Co or Bu–Co or BuBuBu or Co–Co or BuBuCo or Bu–Co or BuBu or Eq–Co or BuBuCo, Bu or EqBu––Co or BuBuCo, Bu or EqBu–Bu or EqBuBuBu–BuCo, Eq or UnCuBu–CoCo, Eq or UnBuBu–CoBuCoBuCoBu or EqRo 19 7/29Ro 7 24/30BuRo 19 7/27Ro 7 38/30Ro 19 7/25Ro 7 60/30Ro 19 35/30
.0096
.010
.012
.01264
.015
.0142
.017
.016
.019
.0193
.021
.0201
.024
.024
.025
.025
.030
.0315
.032
.038
.037
.040
.039
.0359
.0403
.048
.0475
.050
.049
.0508
.057
.0585
.0606
.060
.0641
.073
.071
.074
.077
.0808
.092
.0905
.0925
.094
.1019
.116
.117
.112
.126
.146
.144
.169
.174
.188
.213
.222
.257
.270
.338
.254
.254
.305
.321
.381
.361
.432
.404
.483
.490
.533
.511
.610
.610
.635
.643
.762
.800
.813
.965
.9401.02.940.912
1.0241.221.2071.271.2441.291.451.501.541.521.631.851.801.881.962.052.342.2992.352.3882.5882.952.972.843.203.713.664.2934.424.7755.415.646.536.8508.59
100100112159175202220253278250304404448400475643700754
1,020
1,1111,0001,2161,0321,2901,6201,7701,6001,9001,6272,5802,4262,6012,6002,5814,1104,1003,8314,1064,1006,5306,5126,0886,5036,500
10,38010,37610,404
9,36110,50016,53416,53516,98316,80026,57626,81826,60042,61542,000
.051
.051
.057
.081
.089
.102
.111
.128
.141
.127
.154
.205
.227
.201
.241
.324
.355
.382
.519
.562
.507
.616
.523
.653
.823
.897
.810
.963
.8241.311.231.321.321.312.082.081.942.082.083.313.303.083.303.295.265.255.274.745.328.388.388.618.51
13.3313.6013.4921.6121.2933.72
.21
.30
.35
.48
.55
.61
.69
.77
.87
.78
.971.221.381.251.481.942.192.353.103.493.143.843.283.904.925.555.015.955.097.817.528.028.158.20
12.412.712.112.712.919.820.219.420.220.831.432.032.029.233.850.150.054.053.481.184.183.2
135140213
.31
.45
.52
.72
.82
.911.041.141.291.151.441.822.051.642.202.893.263.504.615.194.675.714.885.807.328.267.458.857.08
11.6011.2011.9012.1011.9018.5018.9018.0018.9019.2029.5030.1028.9030.1031.1046.8047.6047.6043.4049.2074.5074.4080.4079.00
121.00125.00124.00201.00208.00317.00
176.00113.00106.00
70.8067.5055.6053.8044.5042.5047.3038.9027.2025.7029.5024.9016.7016.6015.5010.5010.3011.40
9.4811.30
– 6.776.457.156.107.084.474.824.394.394.472.68
–3.052.732.811.69
–1.87
–1.82
––––
1.10––.71.70–.43.44.29.28.18
577.00371.00348.00232.00221.00182.00176.00146.00139.00155.00128.00
89.2084.2096.8081.7054.8054.4050.8034.4033.8037.4031.1037.10
–22.2021.2023.4020.0023.2014.7015.8014.4014.4014.70
8.79–
10.00–
9.225.54–
6.13–
5.97––––
3.61––
2.332.30–
1.411.44.95.92.59
164.00104.00
92.6065.3059.3051.40
–41.0037.3040.4034.1025.7023.1027.5021.8016.2014.8013.8010.10
9.3310.40
8.53–
8.056.395.556.485.466.604.164.274.133.994.162.522.612.712.612.531.591.641.701.641.641.001.00.98
1.25.99.65.65––.40–––––
538.00340.00303.00214.00194.00169.00
–135.00122.00133.00112.00
84.2075.9090.2071.6053.2048.6045.1033.2030.6034.0028.00
–26.4021.0019.2021.3017.9021.6013.6014.0013.5013.1013.60
8.288.568.888.568.305.215.385.595.255.253.283.283.214.103.242.132.13
––
1.30–––––
1.9863.157
5.020
6.331
7.983
12.690
19.430
30.890
38.95049.120
78.100
124.200
197.500
314.500
7/40Solid7/38Solid7/36Solid7/35Solid7/3410/3619/38Solid7/3216/3619/36Solid7/3019/34Solid7/2810/3019/3226/34SolidSolid7/2616/3019/3041/34Solid19/29419/.011726/3065/34Solid7/.024219/27419/.014741/30Solid7/.030519/25419/.018565/30Solid7/.038519/.023437/.0169105/307/.048619/.0295133/29168/3019/.0374133/27266/30133/25420/30665/30
1Bu - Bunched; Co - Concentric; Eq - Equilay; Ro - Rope; Un - Unilay2Typical D.C. Resistance values for uninsulated wires. Multiply by 1.04 for typical values after insulation3Values are for tinned, heavy tinned, prefused, overcoated or topcoated conductors4Does not meet UL conductor stranding requirements
Ω/M'in. mm circ. mils sq. mm. lbs/M' kg/km. Ω/km. Ω/M' Ω/km.
32
30
28
27
26
24
22
20
19
18
16
14
12
10
8
6
4
2
197
Electronics Technical Information
% Coverage Factorfor Common Coverage:
Cable Design Equations—Braid Shield
D dP
e
C
F % Coverage0.3680.4090.4530.5000.5530.617
606570758085
where:D = diameter under shield, inchesd = diameter of center conductor, inchesC = number of carrierse = diameter of endP = pick (measured in picks per linear inch) = braid angle, degreesW = weight of shield, lbs/M ftn = number of ends in one carrierl = weight of one end in lbs/M ftM = D + build-up of braid on one shield wall, inchesRdc = dc resistance of the braid shield, Ω/M ftrdc = dc resistance of one strand (end) of shield, Ω/M ft% C = percent braid coverageF = % coverage factor
BRAID PICKS PER INCH:
BRAID SHIELD DC RESISTANCE:
% Coverage: %C = (2F– F2) x 100
Rdc = cosrdc , Ω/kft
(n) (C) (cos )
P =(C) (tan )
, PICKS/INCH2∏ (M)
BRAID ANGLE:
BRAID SHIELD WEIGHT:
W =(n) (C) (I)
, LBS/M FTcos
= tan-1 2∏ (D+2e) P , DEGREES
C
198
Technical Information Electronics
Cable Design Equations—Coaxial Cable
COAXIAL CABLE CAPACITANCE:
C = 7.36ε , pF/ftLOG( D )fd
COAXIAL CABLE VELOCITY OF PROPAGATION:
Vp = 100 , %ε1/2
COAXIAL CABLE INDUCTANCE:
L = 0.140 LOG ( D ), µH/ftfd
COAXIAL CABLE IMPEDANCE:
Zo = 138 LOG ( D ), Ωε1/2 fd
COAXIAL CABLE TIME DELAY:
td = 1.016 ε1/2, nsec/ft
COAXIAL CABLE CUTOFF FREQUENCY:
fco = 7.50 , GHzε1/2 (D + fd)
where:C = capacitance, pF/ftε = insulation dielectric constant (see table below)D = diameter under the shield, inchesd = diameter of the center conductor, inchesL = inductance, µH/ftf = strand factor (see Table II page 138)
Zo = characteristic impedance, ΩVp = velocity of propagation, %td = time delay, nsec/ftfco = cutoff frequency, GHz
MATERIAL ε POWER FACTOR, PF
FEP Teflon® (Cellular)FEP Teflon® (Solid)PE (Cellular)PE (Solid)PE (Semi-Solid)
1.402.101.562.261.29
0.00020.00030.00030.00030.0003
199
Electronics Technical Information
Cable Design Equations—Balanced Pair
CAPACITANCE (UNSHIELDED TWISTED PAIR):
C = 2.2 ε , pF/ftLOG
1.3 (D)(f) (d)
CAPACITANCE (SHIELDED TWISTED PAIR):
C = 3.7 ε , pF/ftLOG
1.2 (D)(f) (d)
CAPACITANCE (OVERALL SHIELDED & CABLED):
C = 2.9 ε , pF/ftLOG
1.5 (D)(f) (d)
IMPEDANCE (UNSHIELDED TWISTED PAIR):
Zo = 1016 ε1/2, Ω
C
IMPEDANCE (SHIELDED TWISTED PAIR):
Zo = 276 LOG 1.2 (D) , Ωε1/2 (f) (d)
where:C = mutual capacitance, pF/ftε = insulation dielectric constant (see Table I)f = stranding factor (see Table II)d = diameter of the conductor, inchesD = diameter over the insulation, inchesZo = characteristic impedance Ω
TABLE IDIELECTRIC CONSTANTS & Vp OF INSULATIONS
ε Vp, %MATERIALECTFE (Halar™)PFA Teflon®
PVCPVC (Semi-rigid)PVDF (Kynar™, SOLEF™)PolyethylenePolypropylenePolyurethaneRubber, butylRubber, naturalRubber, SBRRubber, siliconeTFE Teflon®
TPETeflon®
Tefzel®
TABLE IINO. OF STRANDS ƒ
17
19376191
1.0000.9390.9700.9800.9850.988
IMPEDANCE (OVERALL SHIELDED & CABLED):
Zo = 347 LOG 1.5 (D) , Ωε1/2 (f) (d)
2.602.155.003.607.702.292.256.504.05.04.03.12.15.02.102.6
63684553366667395045505769456962
200
Technical Information Electronics
Engineering Prefixes
PREFIX SYMBOLteragiga
megakilo
hectodecadecicentimilli
micronanopico
femtoatto
1012
109
106
103
102
101
10-1
10-2
10-3
10-6
10-9
10-12
10-15
10-18
1,000,000,000,0001,000,000,0001,000,0001,000100100.10.010.0010.0000010.0000000010.0000000000010.0000000000000010.000000000000000001
MULTIPLYING FACTORCONVENTIONAL
TGMkh
dadcmµnpfa
SCIENTIFIC
201
GlossaryElectronics Technical Information
Abrasion Resistance: Resistance to surfacewear.
AC Alternating Current (a.c.): Current in whichthe charge-flow periodically reverses and isrepresented by: I = lcos (2f +) where, I is thecurrent, l is the amplitude, f the frequency, thephase angle.
Accelerated Aging: A test that attempts toduplicate long-time environmental aging incomparatively short time spans.
Accelerator: A chemical additive which hastens achemical reaction under specific conditions.
Accordion: (1) A retractile cable with a series ofequally-spaced transverse folds. (2) A connec-tor contact with a “Z” shaped flat spring topermit high deflection without overstress.
Adapter: A device that enables any or all of thefollowing 1) different sizes or types of plugs tomate with one another or to fit into atelecommunications outlet/connector; 2) therearrangement of leads; 3) large cables withnumerous wires to fan out into smaller groups ofwires, 4) interconnection between cables.
Adhesive Bonded: Cables bonded by adding anadhesive coating to the surface of the cablecomponents, then joining and curing theadhesive to form a cable. See Bonded Cable.
Administration: The method for labeling,identification, documentation and usage neededto implement moves, additions and changes ofthe telecommunications infrastructure.
Admittance: The measure of the ease with whichan alternating current flows in a circuit. Thereciprocal of impedance.
Aerial Cable: A cable suspended in the air onpoles or other overhead structure.
Aging: The change in properties of a material withtime under specific conditions.
Air Core Cable: A cable in which the interstices inthe cable core are not filled with a moisturebarrier.
Air-Handling Plenum: A designated area, closedor open, used for environmental air.
Air Spaced Coaxial Cable: One in which air isessentially the dielectric material. A spirallywound synthetic filament, beads or braidedfilaments may be used to center the conductor.
All-Rubber Cable: A cable in which all intersticesbetween conductors are filled with rubbercompound.
Alligator Clip: A mechanical device shaped likealligator jaws used as a temporary connectionon the end of interconnections wire.
Alloy: A metal formed by combining two or moredifferent metals to obtain desirable properties.
Aluminum Conductor: An aluminum wire orgroup of wires not suitably insulated to carryelectrical current.
Aluminum-Steel Conductor: A compositeconductor made up of a combination ofaluminum and steel wires.
Ambient Temperature: The temperature of amedium (gas or liquid) surrounding an object.
American Wire Gauge (AWG): The standardsystem used for designating wire diameter. Thelower the AWG number, the larger the diameter.Also called the Brown and Sharpe (B&S) wiregauges.
Ampacity: See Current Carrying Capacity.
Ampere: The unit of current. One ampere is thecurrent flowing through one ohm of resistance atone volt potential.
Analog: A signaling format that uses continuousphysical variables such as voltage amplitude orfrequency variations to transmit information.
Anneal: Relief of mechanical stress through heatand gradual cooling. Annealing copper renders itless brittle.
Annular Conductor: A number of wires strandedin three reversed concentric layers around acore.
Annunciator: A signaling device, usually electri-cally operated, that gives an audible or visualsignal (or both) when energized.
Anti-Oxidant: A substance which prevents orslows down oxidation of material exposed to air.
Appliance Wire and Cable: A classificationcovering insulated wire and cable for internalwiring of appliances and equipment.
Arc Resistance: The time required for an arc toestablish a conductive path in a material.
Armored Cable: A cable provided with a wrap-ping of metal for mechanical protection.
Attenuation: The decrease in magnitude of thepower of a signal in transmission betweenpoints. Attenuation is usually measured indecibels per unit length at a specific frequency.
Attenuation to Crosstalk Ratio (ACR): Thedifference between attenuation and crosstalk,measured in dB, at a given frequency. Importantcharacteristic in networking transmission toassure that signal sent down a twisted pair isstronger at the receiving end, after beingattenuated, than are any interference signalsimposed on that same pair by crosstalk fromother pairs, represented by NEXT.
Audio Frequency: The range of frequenciesaudible to the human ear. Usually 20-20,000 Hz.
Backbone: A facility (e.g. pathway, cable orconductors) between telecommunicationsclosets or floor distribution terminals, theentrance facilities and the equipment roomswithin or between buildings.
Backbone Cable or Wire: Cable or wire found inthe backbone, see Backbone.
Balanced Line: A cable having two identicalconductors which carry voltages opposite inpolarity and equal in magnitude with respect toground.
Balun: A device for matching an unbalancedcoaxial transmission line to a balanced two-wiresystem.
Band Marking: A continuous circumferential bandapplied to a conductor at regular intervals foridentification.
Banded Cable: Two or more cables bandedtogether by stainless steel strapping.
Bandwidth: A continuous range of frequenciesextending between two limiting frequencies.Also referred to as a frequency band.
Barrel-Packed: Method of coiling into a fiberdrum for shipment.
Baseband: In data transmission, the use of adedicated end-to-end connection to carry asingle channel only.
Beaded Coax: Coaxial cable with a dielectricconsisting of beads made of various materials.
Belt: Number of layers of insulation on a conduc-tor, or number of layers of jacket on a cable.
Belted-Type Cable: Multiple conductor cablehaving a layer of insulation over the assembledinsulated conductors.
Bend Loss: A form of increased attenuationcaused by (1) having an optical fiber curvedaround a restrictive radius of curvature or (2)microbends caused by minute distortions in thefiber imposed by externally induced forces.
Bend Radius: Radius of curvature that a fiberoptic or metallic cable can bend without anyadverse effects.
Bifilar: A winding made non-inductive by windingtogether (as one wire) two wires carrying currentin opposite directions.
Billion Conductor Feet (BCF): A quantity derivedby multiplying the number of conductors in acable by the amount of cable. Usually used toindicate plant capacity or an annual requirement.
Bimetallic Wire: A wire formed of two differentmetals joined together (not alloyed). It caninclude wire with a steel core clad wire, or platedor coated wire.
Binder: A spirally served tape or thread used forholding assembled cable components in placeawaiting subsequent manufacturing operations.
Binding Post: A device for clamping or holdingelectrical conductors in a rigid position.
Bit: One binary (0 or 1) digit.Blown Jacket: Outer cable covering applied by
controlled inflation of the cured jacket tube thenpulling the cable through it.
Bond Strength: Amount of adhesion betweenbonded surfaces, e.g. in cemented ribbon cable.
Bondable Wire: An insulated wire treated tofacilitate adherence to materials such as pottingcompounds. Also, magnet wires used in makingcoils when bonding the turns together is desired.
Bonded Cable: Cable consisting of pre-insulatedconductors or multiconductor components laid-in parallel and bonded into a flat cable. SeeSolvent-Bonded; Adhesive-Bonded; Film-Bonded.
Bonded Construction: An insulation constructionin which the glass braid and nylon jacket arebonded together.
Bonding: The permanent joining of metallic partsto form an electrically conductive path that willassure electrical continuity and the capacity toconduct safely any current likely to be imposedon it.
Booster: A device inserted into a line (or cable) toincrease the voltage.
Boot: (1) Protective covering over a cable, wire orconnector in addition to the normal jacketing orinsulation. (2) A form placed around wiretermination of a multiple-contact connector tocontain the liquid potting compound before ithardens.
Braid: A fibrous or metallic group of filamentsinterwoven in cylindrical form to form a coveringover one or more wires.
Braid Angle: The smaller of the two anglesformed by the shielding strand and in the axis ofthe cable being shielded.
Braid Carrier: A spool or bobbin on a braid whichholds one group of strands or filamentsconsisting of a specific number of ends. Thecarrier revolves during braiding operations.
202
GlossaryTechnical Information Electronics
Braid Ends: The number of strands used to makeup one carrier. The strands are wound side byside on the carrier bobbin and lie parallel in thefinished braid.
Braiding Machine: Machine used to apply braidsto wire and cable and to produce braidedsleeving and braids for tying or lacing purposes.Braiding machines are identified by the numberof carriers.
Breakdown (Puncture): A disruptive dischargethrough the insulation.
Breakdown Voltage: The voltage at which theinsulation between two conductors breaksdown.
Breakout: The point at which a conductor orgroup of conductors breaks out from amulticonductor cable to complete circuits atvarious points along the main cable.
Bridge: A device used to expand a local areanetwork by forwarding frames between data linklayers.
Bridged Tap: The multiple appearances of thesame cable pair at several distribution points.
British Standard Wire Gauge: A modification ofthe Birmingham Wire Gauge and the legalstandard of Great Britain for all wires. Alsoknown as Standard Wire Gauge (SWG), NewBritish Standard (NBS), English Legal Standardand Imperial Wire Guide.
Broadband: In data transmission, the use of acarrier signal, rather than direct modulation, tocarry several simultaneous channels.
Buffer: (fiber optic) A soft material whichmechanically isolates individual fibers in a fiberoptic cable or bundle from small geometricalirregularities, distortions or roughness ofadjacent surfaces.
Buffing Stripper: A motorized device forremoving flat cable insulation by means ofbuffing wheels that melt the insulation and brushit away from the conductors. Also calledAbrasion Stripper.
Building Entrance Area: See Entrance Room orSpace, Telecommunications.
Building Wire: Wire used for light and power, 600volts or less, usually not exposed to outdoorenvironment.
Bunched Stranding: A group of strands twistedtogether in a random manner and the samedirection without regard to geometricarrangement of specific strands.
Buncher: A machine that twists wires together inrandom arrangement.
Bundle: (fiber optic) A number of fibers groupedtogether, usually carrying a common signal.
Buried Cable: A cable installed directly in theearth without use of underground conduit. Alsocalled “direct burial cable.”
Bus: Wire used to connect two terminals inside ofan electrical unit.
Bushing: A mechanical device used as a lining foran opening to prevent abrasion to wire andcable.
Butt: Joining of two conductors end-to-end, withno overlap and with the axes in line.
Butt Splice: A splice wherein two wires fromopposite ends butt against each other, oragainst a stop, in the center of a splice.
Butt Wrap: Tape wrapped around an object orconductor in an edge-to-edge condition.
Byte: Typically a group of eight binary digits.
Cable: A stranded conductor with or withoutinsulation and other coverings (single-conductorcable), or a combination of conductors (multiple-conductor cable). In fiber optics, a jacketed fiberor jacketed bundle in a form which can beterminated.
Cable Assembly: Typically, the cable andassociated connectors; ready to install.
Cable Clamp: A device used to give mechanicalsupport to the wire bundle or cable at the rear ofa plug or receptacle.
Cable Clamp Adapter: A mechanical adapter thatattaches to the rear of a plug or receptacle toallow the attachment of a cable clamp.
Cable Core: The portion of an insulated cablelying under a protective covering.
Cable Core Binder: A wrapping of tapes or cordsaround the conductors of a multiple-conductorcable used to hold them together.
Cable Filler: The material used in multiple-conductor cables to occupy the interslicesformed by the assembly of the insulatedconductors, thus forming a cable core.
Cable Rack: The vertical or horizontal opensupport (usually made of aluminum or steel) thatis attached to a ceiling or wall.
Cable Sheath: The overall protective coveringapplied to cables.
Cable Tray: A ladder, trough, solid-bottom orchannel raceway system intended for, but notlimited to, the support of telecommunicationsmedia (e.g., cable).
Cable Vulcanizer: Compression molding machineused to repair cable jacketing that has had apart removed for splicing, for adding connectorsor other devices or for replacing damagedsections.
Cabling: (1) A combination of all cables, wire,cords and connecting hardware. (2) Twistingtogether two or more insulated conductors bymachine to form a cable. In fiber optics, amethod by which a group or bundle of fibers ismechanically assembled.
Cabling Factor: Used in the formula forcalculating the diameter of an unshielded,unjacketed cable. D = Kd, where D is the cablediameter, K is the factor and d is the diameter ofone insulated conductor.
Campus: The building and grounds of a complex(e.g. a university, college, industrial park ormilitary establishment).
Canadian Standards Association (CSA): A non-profit independent organization which operatesa listing service for electrical and electronicmaterials and equipment. The Canadiancounterpart of the Underwriter’s Laboratories.
Capacitance: The ratio of the electrostatic chargeon a conductor to the potential differencebetween the conductors required to maintainthat charge.
Capacitance, Direct: The capacitance measuredfrom one conductor to another conductorthrough a single insulating layer.
Capacitance, Mutual: The capacitance betweentwo conductors (typically of a pair) with all otherconductors, including shield, short circuited toground.
Carolprene®: Proprietary rubber compound.
Carrier: The woven element of a braid consistingof one or more ends (strands) which creates theinterlaced effect. Also, a spindle, spool, tube, orbobbin (on a braiding machine) containing yarnor wire, employed as a braid.
Cellular Plastics: Expanded or “foam,” consistsof individual closed cells of inert gas suspendedin a plastic medium, resulting in a desirablereduction of the dielectric constant.
Central Office: The place where communicationscommon carriers terminate customer lines andlocate switching equipment that interconnectsthose lines.
Certificate of Compliance (C of C): A writtenstatement; normally generated by a QualityControl Department, which states that theproduct being shipped meets customer’sspecifications.
Certified Test Report (CTR): A report reflectingactual test data on the cable shipped. Tests arenormally conducted by the Quality ControlDepartment, and show that the product beingshipped meets the required test specifications.
Characteristic Impedance: The impedance that,when connected to the output terminals of atransmission line of any length, makes the lineappear indefinitely long.
Chlorosulfonated Polyethylene (CSPE): Arubbery polymer used for insulations andjackets. Manufactured by E.l. DuPont under thetrade name of Hypalon®.
Cigarette Wrap: Tape insulation wrappedlongitudinally instead of spirally over aconductor.
Circuit: A complete path over which electrons canflow from the negative terminals of a voltagesource through parts and wires to the positiveterminals of the same voltage source.
Circuit Sizes: A popular term for building wiresizes 14 through 10 AWG.
Circular Mil: The area of a circle one mil (.001") indiameter; 7.854 x 10-7 sq. in. Used in expressingwire cross sectional area.
Cladding: Method of applying a layer of metalover another metal whereby the junction of thetwo metals is continuously welded. In fiberoptics, a sheathing intimately in contact with thecore of a higher refractive index material whichserves to provide optical insulation andprotection to the reflection interface.
Closed End Splice: An insulated splice in whichtwo or more wires overlap and enter the splicefrom the same end of the barrel.
Closet, Telecommunications: An enclosed spacefor housing telecommunications equipment,cable terminations and cross-connect cabling.The closet is the recognized location of thecross-connect between the backbone andhorizontal facilities.
Coaxial Cable: A cable consisting of twocylindrical conductors with a common axis,separated by a dielectric.
Coaxial Connector: A connector that has acoaxial construction and is used with coaxialcable.
Coherent Source: (fiber optic) A light sourcewhich emits a very narrow, unidirectional beamof light of one wavelength (monochromatic).
Coil Effect: The inductive effect exhibited by aspiral-wrapped shield, especially above audiofrequencies.
203
GlossaryElectronics Technical Information
Cold Flow: Permanent deformation of theinsulation due to mechanical force of pressure(not due to heat softening).
Color Code: A color system for wire or circuitidentification by use of solid colors, tracers,braids, surface printing, etc.
Commercial Building: A building or portionthereof, that is intended for office use.
Common Axis Cabling: In multiple cableconstructions, a twisting of all conductors abouta “common axis” to result in smaller diameterconstructions. Tends to result in greatersusceptance to electromagnetic andelectrostatic interference.
Compact Conductor: Stranded conductor rolledto deform the round wires to fill the normalinterstices between the wires in a strand.
Composite (Clad) Wire: A wire having a core ofone metal with a fused outer shell of differentmetals.
Composite Conductor: Two or more strands ofdifferent metals assembled and operated inparallel.
Compound: An insulating or jacketing materialmade by mixing two or more ingredients.
Compression Cable: A pipe type cable in whichthe pressure medium is separated from theinsulation by a membrane or sheath.
Concentric: A central core surrounded by one ormore layers of helically wound strands in a fixedround geometric arrangement.
Concentric-Lay Cable: A concentric-layconductor, or a multiple-conductor cablecomposed of a central core surrounded by oneor more layers of helically laid insulatedconductors.
Concentric Strand: A strand that consists of acentral wire or core surrounded by one or morelayers of spirally laid wires.
Concentricity: The measurement of the locationof the center of the conductor with respect tothe geometric center of the circular insulation.
Conductance: The ability of a conductor to carryan electric charge. The ratio of the current flowto the potential difference causing the flow. Thereciprocal of resistance.
Conductivity: The capacity of a material to carryelectrical current—usually expressed as apercentage of copper conductivity (copper being100%).
Conductor: A wire (or combination of wires notinsulated from one another) suitable for carryingelectric current.
Conduit: A rigid or flexible metallic or nonmetallicraceway of circular cross-section through whichcables can be pulled or housed.
Connecting Hardware: A device providingmechanical cable terminations.
Connector: A device used to provide rapidconnect/disconnect service for electrical cableand wire terminations.
Contact: The part of a connector which actuallycarries the electrical current, and are touchedtogether or separated to control the flow.
Contact Inspection Hole: A hole in the cylindricalrear portion of contact used to check the depthto which a wire has been inserted.
Contact Size: The largest size wire which can beused with the specific contact. Also, thediameter of the engagement end of the pin.
Continuity Check: A test to determine whetherelectrical current flows continuously throughoutthe length of a single wire or individual wires in acable.
Continuous Vulcanization: Simultaneousextrusion and vulcanization of rubber-like wirecoating materials.
Contrahelical: Cable spiralling in an oppositedirection than the preceding layer within a wireor cable.
Control Cable: A multi-conductor cable made foroperation in control of signal circuits.
Controlled Impedance Cable: Package of two ormore insulated conductors where impedancemeasurements between respective conductorsare kept essentially constant throughout theentire length.
Copolymer: A compound resulting from thepolymerization of two different monomers.
Copper-Clad: Steel with a coating of copperwelded to it before drawing as opposed tocopper-plated. Synonymous with Copperweld.
Copperweld: The trade name of Flexo WireDivision (Copperweld Steel Corp.) for theircopper-clad steel conductors.
Cord: A small, flexible insulated cable.Cord Set: Portable cords fitted with a wiring
device at one or both ends.Cord, Telecommunications: A cable using
stranded conductors for flexibility, as indistribution cords or line cords. Line cords canalso use tinsel conductors.
Core: In cables, a component or assembly ofcomponents over which other materials areapplied, such as additional components, shield,sheath or armor. In fiber optics, the transparentglass or plastic section with a high refractiveindex through which the light travels by internalreflections.
Corona: A discharge due to ionization of airaround a conductor due to a potential gradientexceeding a certain critical value.
Corona Resistance: The time that the insulationwill withstand a specified level of field-intensifiedionization that does not result in the immediatecomplete breakdown of the insulation.
Corrosion: The destruction of the surface of ametal by chemical reaction.
Coupling Loss: (fiber optic) Signal losses due tosmall differences in numerical aperture, corediameter, core concentricity and tolerances insplicing connectors when two fibers are aligned.Also known as Splicing Loss and Transfer Loss.
Coupling Ring: A device used on cylindricalconnectors to lock plug and receptacle together.
Coverage: The calculated percentage whichdefines the completeness with which a metalbraid covers the underlying surface. The higherpercentage of coverage, the greater theprotection against external interference.
Covering: Textile braid or jacket of rubber, plasticsor other materials applied over wire and cablesto provide mechanical protection andidentification.
Crazing: The minute cracks on the surface ofplastic materials.
Creep: The dimensional change with time of amaterial under load.
Creepage: The conduction of electricity acrossthe surface of a dielectric.
Creepage Path: The path across the surface of adielectric between two conductors.
Creepage Surface: An insulating surface whichprovides physical separation as a form ofinsulation between two electrical conductors ofdifferent potential.
Crimp: Act of compressing a connector barrelaround a cable in order to make an electricalconnection.
Crimp Termination: Connection in which a metalsleeve is secured to a conductor bymechanically crimping the sleeve with pliers,presses or automated crimping machines.
Cross-Connect: A facility enabling the terminationof cable elements and their interconnection,and/or cross-connection, primarily by means ofa patch cord or jumper.
Cross-Linked: Inter-molecular bonds betweenlong-chain thermoplastic polymers by chemicalor electron bombardment means. The propertiesof the resulting thermosetting material areusually improved.
Crosstalk: Undesired electrical currents inconductors caused by electromagnetic orelectrostatic coupling from other conductors orfrom external sources. Also, leakage of opticalpower from one optical conductor to another.
CSA: Canadian Standards Association.C-SJ: Same as SJ except extra-flexible conductor.C-SJO: Same as SJO except extra-flexible
conductor.Cure: To change the physical properties of a
material by chemical reaction.Curing Cycle: The time, temperature and pressure
required for curing.Curl: The degree to which a wire tends to form a
circle after removal from a spool. An indication ofthe ability of the wire to be wrapped aroundposts in long runs.
Current: The rate of transfer of electricity.Practical unit is the ampere which represents thetransfer of one coulomb per second. In a simplecircuit, current (I) produced by a cell orelectromotive force (E) when there is an externalresistance (R) and internal resistance (r) is: I =
Current Carrying Capacity: The maximumcurrent an insulated conductor can safely carrywithout exceeding its insulation and jackettemperature limitations.
Customer Premises: Building(s) with grounds andappurtenances (belongings) under the control ofthe customer.
Cut-Through Resistance: The ability of a materialto withstand mechanical pressure, usually asharp edge or small radius, without separation.
Cycle: The complete sequence including reversalof the flow of an alternating electric current.
Decibel (dB): A unit to express differences ofpower level. Used to express power gain inamplifiers or power loss in passive circuits orcables.
Delay Line: A cable made to provide very lowvelocity of propagation with long electrical delayfor transmitted signals.
Demarcation Point: A point where the operationalcontrol or ownership changes.
E R + r
204
GlossaryTechnical Information Electronics
Depth of Crimp: Thickness of the crimped portionof a connector measured between two oppositepoints on the crimped surface.
Derating Factor: A factor used to reduce thecurrent carrying capacity of a wire when used inenvironments other than that for which the valuewas established.
Detector: (fiber optic) A device that picks up lightfrom fiber and converts the information into anelectrical signal.
Device, As Related to a Work Station: An itemsuch as a telephone, personal computer orgraphic or video terminal.
Device, As Related to Protection: A protector, aprotector mount, a protector unit or a protectormodule.
Dielectric: An insulating medium which intervenesbetween two conductors and permitselectrostatic attraction and repulsion to takeplace across it.
Dielectric Breakdown: The voltage required tocause an electrical failure or breakthrough of theinsulation.
Dielectric Constant (K): The ratio of thecapacitance of a condenser with dielectricbetween the electrodes to the capacitance whenair is between the electrodes. Also calledPermittivity and Specific Inductive Capacity.
Dielectric Loss: Power dissipated in an insulatingmedium as the result of the friction caused bymolecular motion when an AC electric field isapplied.
Dielectric Strength: The voltage which aninsulation can withstand before breakdownoccurs. Usually expressed as a voltage gradient(such as volts per mil).
Dielectric Test: A test in which a voltage higherthan the rated voltage is applied for a specifiedtime to determine the adequacy of the insulationunder normal conditions.
Digital: Transmission data representative bydiscrete characters.
Dip Coating: An insulating coating applied to theconductor by passing the conductor through anapplicator containing liquid insulating medium.
Direct Burial Cable: A cable installed directly inthe earth.
Direct Capacitance: The capacitance measureddirectly from conductor to conductor through asingle insulating layer.
Direct Current (d.c.): An electric current whichflows in only one direction.
Direct Current Resistance (DCR): The resistanceoffered by any circuit to the flow of directcurrent.
Direction of Lay: The lateral direction in which thestrands of a conductor run over the top of thecable conductor as they recede from anobserver looking along the axis of the conductoror cable. Also applies to twisted cable.
Discrete Wiring: Wire or wires having distinctidentity and purpose.
Dispersion: (fiber optic) The variation of therefractive index of a material with wavelength,causing light of different wavelengths to travel atdifferent velocities in the material.
Disruptive Discharge: A sudden, large increasein current through an insulation medium due tothe complete failure of the medium under theelectrostatic stress.
Dissipation Factor: The tangent of the loss angleof the insulating material. (Also referred to asloss tangent, tan , and approximate powerfactor.)
Distribution Cable: In telecommunications andCATV systems, the transmission cable betweenthe distribution amplifier and the drop wire.
Distribution Frame: A structure with terminationsfor connecting the permanent cabling of a facilityin such a manner that interconnection or cross-connections may be readily made.
Disturbed Conductor: A conductor that receivesenergy generated by the field of anotherconductor or an external source such as atransformer.
Drain Wire: In a cable, the uninsulated wire laidover the component or components and usedas a ground connection.
Draw Feed Stock: Rod or wire that issubsequently drawn to a smaller size.
Drawing: In wire manufacture, pulling the metalthrough a die or series of dies to reducediameter to a specified size.
Drop Ceiling: See False Ceiling.Drop Wire: In telecommunications and CATV
systems, the transmission cable from thedistribution cable to a dwelling.
Dual Coaxial Cable: Two individually insulatedconductors laid parallel or twisted and placedwithin an overall shield and sheath.
Duct: 1) A single enclosed raceway for wires orcables. See also Conduit, Raceway; 2) a singleenclosed raceway for wires or cables usuallyused in soil or concrete, 3) an enclosure in whichair is moved. Generally part of the HVAC systemof a building.
Duplex: Two way data transmission on a four-wiretransmission line or two fiber.
Duplex Cable: (1) A cable composed of twoinsulated single-conductor cables twistedtogether. (2) A cable composed of two fibers,typically 62.5/125 m Multi-Mode, placed inparallel under a thermoplastic sheath.
Duplex Parallel: Typically used in thethermocouple industry to denote two parallelconductors of dissimilar metals insulated inparallel without twist and jacketed. Commonlyapplied to thermocouple grades and extensionwires.
Eccetricity: Like concentricity, a measure of thecenter of a conductor’s location with respect tothe circular cross section of the insulation.Expressed as a percentage of displacement ofone circle within the other.
Eddy Current: Circulating currents induced inconducting materials by varying magnetic fields.
Elastomer: A rubber or rubber-like material whichwill stretch repeatedly to 200 percent or moreand return rapidly and with force to itsapproximate original shape.
Electro-Tinned: Electrolytic process of tinningwire using pure tin.
Electrode: A conductor through which a currententers or leaves a nonmetallic conductor.
Electromagnetic Coupling: Energy transfer bymeans of a varying magnetic field.
Electromagnetic Field: A rapidly moving electricfield and its associated moving magnetic field.
Electromagnetic Induction: The production of avoltage in a coil due to a change in the numberof magnetic lines of forces (flux linkages) passingthrough the coil.
Electromagnetic Interference (EMI): Theinterference in signal transmission or receptionresulting from the radiation of electrical andmagnetic fields. Synonym: Radio FrequencyInterference.
Electromotive Force (e.m.f.): Pressure orvoltage. The forces which cause current to flowin a circuit.
Electronic Wire and Cable: A length ofconductive or semiconductive material used inan electronic application.
Electrostatic: Pertaining to static electricity, orelectricity at rest. An electric charge, forexample.
Elongation: The fractional increase in the length ofa material stressed in tension.
Embossing: A marker identification by means ofthermal indentation leaving raised lettering onthe sheath material of cable.
Emergency Overload: Load which occurs whenlarger than normal currents are carried through acable or wire over a certain period of time.
Enameled Wire: A conductor with a baked-onenamel film insulation. In addition to magnetwire, enameled insulation is used onthermocouple type wires and other wires.
Ends: In braiding, the number of essentiallyparallel wires of threads on a carrier.
Energize: To apply rated voltage to a circuit ordevice in order to activate it.
Entrance Facility, Telecommunications: Anentrance to a building for both public and privatenetwork service cables (including antennae)including the entrance point at the building walland continuing to the entrance room or space.
Entrance Point, Telecommunications: The pointof emergence of telecommunicationsconductors through an exterior wall, a concretefloor slab or from a rigid metal conduit orintermediate metal conduit.
Entrance Room or Space, Telecommunications:A space in which the joining of inter- or intra-building telecommunications backbone facilitiestakes place. An entrance room may also serveas an equipment room.
Equilay: More than one layer of helically laid wireswith the direction of lay reversed for successivelayers, but with the length of lay the same foreach layer.
Equipment Room, Telecommunications: Acentralized space for telecommunicationsequipment that serves the occupants of thebuilding. An equipment room is considereddistinct from a telecommunications closetbecause of the nature of complexity or theequipment.
Etched Wire: A process applied to fluoroplasticwire in which the wire is passed through asodium bath to create a rough surface to allowepoxy resin to bond the fluoroplastic.
Exit Angle: The angle between the outputradiation vectors and the axis of the fiber or fiberbundle.
External Interference: The effects of electricalwaves or fields which cause sounds other thanthe desired signal. Static.
205
GlossaryElectronics Technical Information
External Wiring: Electronic wiring whichinterconnects subsystems within the system.
Extruded Cable: Cable with conductors which areuniformly insulated and formed by applying ahomogeneous insulation material in acontinuous extrusion process.
Extrusion: Method of continuously forcing plastic,rubber, or elastomer material through an orificeto apply insulation or jacketing over a conductoror cable core.
False Ceiling: A ceiling that creates an area orspace between the ceiling material and thestructure above the material. Synonym: DropCeiling, Suspended Ceiling.
Farad: A unit of electrical capacity.Fatigue Resistance: Resistance to metal
crystallization which leads to conductors orwires breaking from flexing.
Feed-Through Insulators: Insulators that carry ametal conductor through the chassis whilepreventing the “hot” lead from shorting to theground chassis.
Feedback: Energy that is extracted from a high-level point in a circuit and applied to a lowerlevel. Positive feedback reduces the stability of adevice and is used to increase the sensitivity orproduce oscillation in a system. Negativefeedback, also called inverse feedback,increases the stability of a system as thefeedback improves stability and fidelity.
Feeder Cable: In telecommunication or CATVsystems, the transmission cable from the headend (signal pickup) to the trunk amplifier. Alsocalled a trunk cable.
Feedthrough: (1) A conductor that connectspatterns on opposite sides of a PCB. Also calledInterfacial connection. (2) A connector orterminal block, usually having double-endedterminals which permit simple distribution andbussing of electrical circuits.
Ferrous: Composed of and/or containing iron. Aferrous metal exhibits magnetic characteristics.
Ferrule: A short tube used to make solderlessconnections to shielded or coaxial cable.
Fiber: A thread or threadlike structure. Also, asingle discrete element used to transmit optical(light wave) information.
Fiber Dispersion: (fiber optic) Pulse spreading ina fiber caused by differing transit times ofvarious modes.
Fiber Optics: A lightwave or opticalcommunications system in which electricalinformation is converted to light energy,transmitted to another location through opticalfibers, and is there converted back into electricalinformation.
Fiber Tubing: A loose, crush-resistant cylinderapplied over individual fibers to providemechanical protection.
Field: An area of influence around a magnet orelectric charge.
Field Coil: A suitable insulated winding to bemounted on a field pole to magnetize it.
Figure 8 Cable: An aerial cable configuration inwhich the conductors and the steel strand whichsupports the cable are integrally jacketed. Across-section of the finished cable approximatesthe figure “eight.”
Filament: Fiber characterized by extreme length.
Filled Cable: A telephone cable construction inwhich the cable core is filled with a material thatwill prevent moisture from entering or passingthrough the cable.
Filler: (1) A material used in multiconductor cablesto occupy large interstices formed by theassembled conductors. (2) An inert substanceadded to a compound to improve properties ordecrease cost.
Film: A thin plastic sheet.Fine Stranded Wire: Stranded wire with
component strands of 36 AWG or smaller.Firestop: A material, device or assembly of parts
installed in a cable system in a fire-rated wall orfloor to prevent passage of flame, smoke orgasses through the rated barrier.
Flame Resistance: The ability of a material not topropagate flame once the heat source isremoved.
Flammability: The measure of the material’sability to support combustion.
Flashover: A disruptive discharge around or overthe surface of a solid or liquid insulator.
Flat Braid: A woven braid of tinned copperstrands rolled flat at time of manufacture to aspecified width.
Flat Cable: A cable with two smooth orcorrugated but essentially flat surfaces.
Flat Conductor: A wire having a rectangularcross- section as opposed to a round or squareconductor.
Flat Conductor Cable: A cable with a plurality offlat conductors.
Flexfoil®: Proprietary aluminum laminatedshielding tapes.
Flex Life: The measurement of the ability of aconductor or cable to withstand repeatedbending.
Flexibility: The ease with which a cable may be bent.
Flexible: That quality of a cable or cablecomponent which allows for bending under theinfluence of outside force, as opposed tolimpness which is bending due to the cable’sown weight.
Floating: Referring to a circuit which has noconnection to ground.
Flux: (1) The lines of force which make up anelectrostatic field. (2) The rate of flow of energyacross or through a surface. (3) A substanceused to promote or facilitate fusion.
FNC: Federal Networking Council (formerly FRICC).Foamed Plastics: See Cellular Plastic.Foil: A thin, continuous sheet of metal.Free Connector: A connector for attachment to
the free end of a wire or cable.Frequency: The number of times a periodic action
occurs in a unit of time. The number of cyclesthat an electric current completes in one second.
Frequency Response: The characteristic of adevice denoting the range of frequencies overwhich it may be used effectively.
Funnel Entry: Flared or widened entrance to aterminal or connector wire barrel.
Fuse Wire: Wire made from an alloy that melts ata relatively low temperature.
Fused Coating: A metallic coating which hasbeen melted and solidified, forming ametallurgical bond to the base material.
Fused Conductors: Individual strands of heavytinned copper wire stranded together and thenbonded together by induction heating.
Fused Spiral Tape: A PTFE insulated hookupwire. The spiral wrapped conductor is passedthrough a sintering oven where overlaps arefused together.
Gain: The increase of voltage, current or powerover a standard or previous reading. Usuallyexpressed in decibels.
Galvanometer: An instrument for detecting ormeasuring small electrical current.
Gas-Filled Cable: A self-contained pressure cablein which the pressure medium is an inert gashaving access to the insulation.
Gauge: A term used to denote the physical size ofa wire.
Giga: A numerical prefix denoting one billion (109).Gigahertz (GHz): A unit of frequency equal to one
billion hertz.Gimmick: A short length of wire soldered onto a
circuit component and used as a smalladjustable capacitor.
Graded-lndex: A type of optical fiber in which therefractive index of the core is in the form of aparabolic curve, decreasing toward the cladding.This type of fiber provides high bandwidthcapabilities.
Ground: A conducting connection, whetherintentional or accidental, between an electricalcircuit (e.g. telecommunications) or equipmentand the earth, or to some conducting body thatserves in place of the earth.
Ground Conductor: A conductor in a transmissioncable or line that is grounded.
Ground Insulation: The insulation used betweena winding and the magnetic core or otherstructural parts, usually at ground potential.
Ground Loop: The generation of undesirablecurrent flow within a ground conductor, owing tothe circulation currents which originate from asecond source of voltage.
Ground Plane: Expanded copper mesh which islaminated into some flat cable constructions asa shield.
Ground Potential: Zero potential with respect tothe ground or earth.
Hard Drawn Copper Wire: Copper wire that hasnot been annealed after drawing.
Harness: An arrangement of wires and cablesusually with many breakouts, which have beentied together or pulled into a rubber or plasticsheath, used to interconnect an electric circuit.
Hash Mark Stripe: A non-continuous helicalstripe applied to a conductor for identification.
Heat Distortion: Distortion of flow of a material orconfiguration due to the application of heat.
Heat Seal: Method of sealing a tape wrap jacketby means of thermal fusion.
Heater Cord: Flexible stranded copper conductor,cotton wrapped, with rubber insulation andasbestos roving.
Helical Stripe: A continuous, colored, spiral stripeapplied to a conductor for circuit identification.
Helix: Spiral winding.Henry: The unit of inductance.Hertz (Hz): A term replacing cycles-per-second as
an indication of frequency.Heterogeneous Insulation: A cable insulating
system composed of two or more layers ofdifferent insulating materials.
206
GlossaryTechnical Information Electronics
High-Temperature Wire and Cable: Electricalwire and cables having thermal operatingcharacteristics of 150°C and higher.
High Voltage: Generally, a wire or cable with anoperating voltage of over 600 volts.
Holding Strength: Ability of a connector to remainassembled to a cable when under tension.
Homogeneous Insulation: A complete cableinsulation structure whose components cannotbe identified as layers of different materials.
Hook-up Wire: A wire used for low-current, low-voltage (under 1000 volts) applications withinenclosed electronic equipment.
Horizontal Cabling: The wiring/cabling betweenthe telecommunications outlet/connector andthe horizontal cross-connect.
Horizontal Cross-Connect: A cross-connect ofhorizontal cabling to other cabling, e.g.horizontal, backbone or equipment.
Hot Stamping: Method of alpha numericalcoding. Identification markings are made bypressing heated type and marking foil intosoftened insulation surfaces. See SurfacePrinting.
Hot Tin Dip: A process of passing bare wirethrough a bath of molten tin to provide a coating.
Hybrid Cable: An assembly of two or more cables(of the same or different types or categories)covered by one overall sheath.
Hygroscopic: Capable of absorbing moisturefrom the air.
Hypalon®: DuPont’s trade name for theirchlorosulfonated polyethylene, an ozone-resistant synthetic rubber.
Impact Tool: Device used to punch newconductor onto IDs. This tool is typicallyequipped with a cutting blade for either 66 or110 blocks.
Impedance: The total opposition that a circuitoffers to the flow of alternating current or anyother varying current at a particular frequency. Itis a combination of resistance R and reactanceX, measured in Ω.
Impedance-Matching Transformer: Atransformer designed to match the impedanceof one circuit to that of another (BALUN).
Impulse: A surge of unidirectional polarity.Impulse Strength: The voltage breakdown of
insulation under voltage surges on the order ofmicroseconds in duration.
Impulse Test: An insulation test in which thevoltage applied is an impulse voltage ofspecified wave shape.
Incoherent Source: (fiber optic) A light sourcewhich emits wide, diffuse beams of light of manywave lengths.
Index-Matching Fluid: (fiber optic) Fluid withrefractive index same as fiber core; used to fill airgap between fiber ends at connectors.
Index of Refraction: The ratio of light velocity in avacuum to its velocity in a given transmittingmedium.
Inductance: The property of a circuit or circuitelement that opposes a change in current flow,thus causing current changes to lag behindvoltage changes. It is measured in henrys.
Inductive Coupling: Crosstalk resulting from theaction of the electromagnetic field of oneconductor on the other.
Infrastructure, Telecommunications: Acollection of those telecommunicationscomponents, excluding equipment, thattogether provide the basic support for thedistribution of all information within a building orcampus.
Insertion Loss: As measure of the attenuation ofa device by determining the output of a systembefore and after the device is inserted into thesystem.
Insertion Tool: A small, hand-held tool used toinsert contacts into a connector.
Insulated Wire: A conductor of electricity coveredwith a non-conducting material.
Insulating Joint: A device which mechanicallycouples and electrically insulates the sheath andarmor of contiguous lengths of cable.
Insulation: A material having high resistance tothe flow of electric current. Often called adielectric in radio frequency cable.
Insulation Adhesion: The degree of tightness ofthe insulation over the base conductor,measured in terms of force required to remove aspecified length of insulation from the wire.
Insulation Crimp: The area of a terminal, splice orcontact that has been formed around theinsulation of the wire.
Insulation Grip: Extended cylinders at the rear ofcrimp-type contacts designed to accept thebared wire and a small length of its insulation.
Insulation Piercing: A method of crimpingwhereby lances cut the insulation of the wiresand enter into the strands to make electricalcontact.
Insulation Resistance: The ratio of the appliedvoltage to the total current between twoelectrodes in contact with a specific insulation,usually expressed in megΩ-M feet.
Insulation System: All of the insulation materialsused to insulate a particular electrical orelectronic product.
Integral Belt: A layer of insulation orsemiconductive material applied by extrusionover two or more insulated, twisted or parallelconductors, to form a round, smooth diameter.
Interconnect: A connection scheme that providesfor the direct connection of individual cables toanother cable or to an equipment cable withouta patch cord.
Interconnecting Cable: The wiring betweenmodules, between units or the larger portions ofa system.
Interconnecting Wire: The physical wiringbetween components (outside a module),between modules, between units or betweenlarger portions of a system or systems.
Interconnection: Mechanically joining devicestogether to complete an electrical circuit.
Interface: The two surfaces on the contact side ofboth halves of a multiple-contact connectorwhich face each other when the connector isassembled.
Intermediate Cross-Connect: A cross-connectbetween 1st level and 2nd level backbonecabling.
Internal Wiring: Electronic wiring whichinterconnects components, usually within asealed subsystem.
Interstices: Voids or valleys between individualstrands in a conductor or between insulatedconductors in a multiconductor cable.
Ionization Voltage (Corona Level): The minimumvalue of falling rms voltage which sustainselectrical discharge within the vacuous or gas-filled spaces in the cable construction orinsulation.
Irradiation: In insulations, the exposure of thematerial to high energy emissions for thepurpose of favorably altering the molecularstructure.
Jack: A plug-in type terminal widely used in anelectronic apparatus for temporary connections.
Jacket: An outer protective sheath over primaryinsulation, braids, shields, cable components orover the cable itself. In fiber optics, a covering,over a fiber, bundle of fibers or cable whichprotects against the environment.
JAN Specification: Joint Army-Navy specification(replaced by current Military Specifications).
Jumper: An assembly of twisted pairs withoutconnectors, used to join telecommunicationscircuits/links at the cross connect.
Junction: A point in a circuit where two or morewires are connected.
Keying: The mechanical feature of a connectorsystem that guarantees correct orientation of aconnection, or prevents the connection to a jack,or to an optical fiber adapter of the same typeintended for another purpose.
Kynar®: Pennwalt trade name for polyvinylidenefluoride. Typically used as insulation for wirewrap wire.
Lacing and Harnessing: A method of groupingwires by securing them in bundles of designatedpatterns.
Lacquer: A liquid resin or compound applied totextile braid to prevent fraying, moistureabsorption, etc.
Laminated Tape: A tape consisting of two ormore layers of different materials bondedtogether.
Laser Diode: (fiber optic) A semiconductor diodethat, when pulsed, a laser diode emits coherentlight.
Launch Angle: (fiber optic) The angle between theradiation vector and the axis of the fiber or fiberbundle.
Lay: The length measured along the axis of a wireor cable required for a single strand (in strandedwire) or conductor (in cable) to make onecomplete turn about the axis of the conductor orcable.
Layer: Consecutive turns of a coil lying in a singleplane.
Leaching and Non-Leaching: In a leaching wire,the plasticizer will migrate when exposed toheat. A non-leaching wire will retain its plasticizerunder extreme temperature conditions andremain flexible after baking.
Lead: A wire, with or without terminals, thatconnects two points in a circuit.
Lead-Cured: A cable that is cured or vulcanized ina metallic lead mold.
Lead Dress: The placement or routing of wire andcomponent leads in an electrical circuit.
Lead-in: The conductor or conductors thatconnect the antenna proper to electronicequipment.
Leakage Current: The undesirable flow of currentthrough or over the surface of an insulation.
207
GlossaryElectronics Technical Information
Life Cycle: A test to determine the length of timebefore failure in a controlled, usually accelerated,environment.
Light Commercial Building: A building or portionthereof that is intended for use with one to four(1-4) non-residential exchange access lines pertenant.
Light-Intensity Ratio: (fiber optic) Ratio of inputlight intensity to the output light intensity.
Light Source: (fiber optic) An object capable ofemitting light. In fiber optics, the light source isnormally an LED or a laser.
Lightguide: (fiber optic) A flexible bundle of fibersused to transmit light.
Lightwave Communications: (fiber optic)Communications using light to carry theinformation.
Limits of Error: The maximum deviation (in degrees of percent) of a thermocouple orthermocouple extension wire from standard emf-temperature to be measured.
Limpness: The ability of a cable to lay flat orconform to a surface.
Line Balance: The degree to which theconductors of a cable are alike in their electricalcharacteristics with respect to each other, toother conductors and to ground.
Line Drop: A voltage loss occurring between anytwo points in a transmission line, due to theresonance, reactance or leakage of the line.
Line Loss: The total of the various energy lossesoccurring in a transmission line.
Line Voltage: Voltage existing in a cable or circuit.Link: An assembly of telecommunications
facilities between two points, not includingterminal equipment.
Listed: Equipment included in a list published byan organization, acceptable to the authorityhaving jurisdiction, that maintains periodicinspection of production of listed equipment,and whose listing states either that theequipment or material meets appropriatestandards or has been tested and found suitablefor use in a specified manner.
Local Area Network (LAN): A geographicallylimited communications network intended forthe local transport of data, video and voice.
Longitudinal Shield: A tape shield, flat orcorrugated, applied longitudinally with the axisof the core being shielded.
Longitudinal Wrap: Tape applied longitudinallywith the axis of the core being covered.
Loop Resistance: The total resistance of twoconductors measured round-trip from one end.Commonly used term in the thermocoupleindustry.
Looping-in: Wiring method which avoids teejoints by carrying the conductor or cable to andfrom the point to be supplied.
Loss: Energy dissipated without accomplishinguseful work.
Loss Factor: The product of the dissipation anddielectric constant of an insulating material.
Lossy Line: A cable having large attenuation perunit of length.
Low-Loss Dielectric: An insulating material thathas a relatively low dielectric loss, such aspolyethylene or Teflon®.
Low-Noise Cable: Cable configuration speciallyconstructed to eliminate spurious electricaldisturbances caused by capacitance changes orself-generated noise induced by either physicalabuse or adjacent circuitry.
Low Tension: Low voltage, as applied to ignitioncable.
Lug: Termination, usually crimped or soldered tothe conductor, with provision for screwing on tothe terminal.
m: Meter.Magnet Wire: Insulated wire intended for use in
windings on motor, transformer and other coilsfor electromagnetic devices.
Magnetic Field: The region within which a bodyor current experiences magnetic force.
Magnetic Flux: The rate of flow of magneticenergy across or through a surface (real orimaginary).
Magnetic Noise: Caused by change in currentlevel, e.g. ac powerline (creates magnetic fieldaround the cable) this magnetic field causes themagnetic noise.
Main Cross-Connect: A cross-connect for 1stlevel backbone cables, entrance cables andequipment cables.
Marker Tape: A tape laid parallel to theconductors under the sheath in a cable,imprinted with the manufacturer’s name and thespecification to which the cable is made.
Master Antenna Television (MATV): Acombination of components providing multipletelevision receiver operations from one antennaor group of antennas normally on a singlebuilding.
Material Scattering Loss: (fiber optics) Loss dueto fluctuations in the refractive index and toinhomogeneities in material composition andtemperature.
Media, Telecommunications: Wire, cable orconductors used for telecommunications.
Megarad: A unit for measuring radiation dosage.Messenger: Supporting member, usually a high-
strength steel wire, used to suspend aerial cable.The messenger may be an integral part of thecable, or exterior to it (lashed messenger).
Microbending Loss: (fiber optic) Loss due tosmall geometrical irregularities along the core-clad interface of the fiber.
Microfarad: One-millionth of a farad, commonlyabbreviated mF.
Micromicrofarad: One-millionth of a microfarad.(uuf, uufd, mmf, mmfd F are commonabbreviations.)
Microwave: A short (usually less than 30 cm.)electrical wave.
Mil: A unit used in measuring diameter of a wire orthickness of insulation over a conductor. One-one thousandth of an inch (.001").
Mineral-Insulated: Cable and thermocouple wireconsisting of one or more conductorssurrounded by magnesium oxide insulation andenclosed in a liquid- and gas-tight metallicsheathing.
Miniature Wire: Insulated conductors ofapproximately 20-34 AWG.
Mis-Match: A termination having a differentimpedance than that for which a circuit or cableis designed.
Mode: One of the components of a generalconfiguration of a propagating wave front.
Modem: Device which places and receives datasignals over a common carrier’s communicationfacility.
Modular Jack: This term is outmoded, seeOutlet/Connector, Telecommunications.
Modular Plug: A telecommunications connectorfor wire or cords per the Part 68 Rules. Amodular plug can have 6 or 8 contact positions,but not all the positions need be equipped withcontacts.
Modulation: A process whereby certaincharacteristics of a wave, often called the carrier,are varied or selected in accordance with amodulating function.
Modulus of Elasticity: The ratio of stress to strainin an elastic material.
Moisture Absorption: The amount of moisture, inpercentage, that a material will absorb underspecified conditions.
Moisture Resistance: The ability of a material toresist absorbing moisture from the air or whenimmersed in water.
Molded Plug: A connector molded on either endof a cord or cable.
Monomer: The basic chemical unit used inbuilding a polymer.
Motor Lead Wire: Wire which connects to thefragile magnet wire found in coils, transformersand stator or field windings.
Multiconductor: More than one conductor withina single cable complex.
Multimode Optical Fiber: An optical fiber that willallow many bound modes to propagate. Thefiber may be either a graded-index or step-indexfiber. See also: Optical Fiber Cable.
Multiple Conductor Cable: A combination of twoor more conductors cabled together andinsulated from one another and from sheath orarmor where used.
Multiple Conductor Concentric Cable: Aninsulated central conductor with one or moretubular stranded conductors laid over itconcentrically and insulated from one another.
Multiplexing: Simultaneous transmission of twoor more messages over the same cable pair.
Mutual Capacitance: Capacitance between twoconductors when all other conductors areconnected together to shield and ground.
Mylar®: DuPont trademark for polyester film.Nanometer (nm): One billionth of a meter
(10–9 meter).Nanosecond: One billionth of a second
(10-9 seconds).National Electric Code (NEC): A set of
regulations governing construction andinstallation of electrical wiring and apparatus inthe United States, established by the AmericanNational Board of Fire Underwriters.
Neoprene: A synthetic rubber with goodresistance to oil, chemical and flame. Also calledpolychloroprene.
Noise: In a cable or circuit, any extraneous signalwhich tends to interfere with the signal normallypresent in or passing through the system.
Nomex®: DuPont trademark for a temperature-resistant, flame-retardant nylon.
Non-Contaminating: Type of PVC jacket materialwhose plasticizer will not migrate into thedielectric of a coaxial cable and thus avoidscontaminating and destroying the dielectric.
208
GlossaryTechnical Information Electronics
Nylon: Thermoplastic with good chemical andabrasion resistance.
NVP: Nominal Velocity of Propagation.Off Center: Conductor displaced within the cross-
section of its insulation.Offgassing: Percentage of a specified gas
released during the combustion of insulation orjacketing material.
Ohm: A unit of electrical resistance.Oil Aging: Cable aged in an accelerated manner
by placement in an oil bath and heated to a pre-set temperature for a stated time.
Oil-Filled Cable: A self-contained pressure cablein which the pressure medium is low viscosity oilhaving access to the insulation.
Opaque: (fiber optic) Not permitting the passageof light.
Open Cell: Foamed or cellular material with cellswhich are generally interconnected.
Optical Communication Cable: (fiber optic) Fiberwith a protective jacket around it.
Optical Conductors: (fiber optic) Materials whichoffer a low optical attenuation to transmission oflight energy.
Optical Fiber Cable: An assembly consisting ofone or more optical fibers.
Optical Fiber Duplex Adapter: A mechanicalmedia termination device designed to align andjoin two duplex connectors.
Optical Fiber Duplex Connector: A mechanicalmedia termination device designed to transferoptical power between two pairs of opticalfibers.
Optical Waveguide: (fiber optic) A fiber used foroptical communications. Analogous to awaveguide used for microwavecommunications.
Oscillatory Surge: A surge which includes bothpositive and negative polarity values.
Outgassing: The dissipation of gas from adielectric evidencing decomposition.
Outlet Box, Telecommunications: A metallic ornonmetallic box mounted within a wall, floor orceiling and used to hold telecommunicationsoutlet/connectors or transition devices.
Outlet/Connector, Telecommunications: Aconnecting device in the work area on whichhorizontal cable terminates.
Overall Diameter: Finished diameter over wire orcable.
Overcoat Conductor: A stranded conductormade from individual strands of tin-coated wirestranded together, and then given an overall tincoat.
Overlap: The amount the trailing edge laps overthe leading edge of a spiral tape wrap.
Oxygen Index: Percentage of oxygen necessaryto support combustion in a gas mixture.
Ozone: Reactive form of oxygen, typically foundaround electrical discharges and present in theatmosphere in small quantities.
Packing Fraction: (fiber optic) The ratio of activecross-sectional area of fiber core, or cores, tothe total end surface of the fiber, or fiber bundle.
Pair: Two insulated wires of a single circuitassociated together, also known as a “balance”transmission line.
Parallel Pair: A duplex construction of twoinsulated conductors laid parallel and thencovered overall with a braid or jacket.
Parallel Stripe: A stripe applied longitudinally ona wire or cable parallel to the axis of theconductor.
Patch Cord: A length of cable with connectors onone or both ends used to jointelecommunications links/circuits at the cross-connect.
Patch Cord Cable: Bulk cable used in themanufacture of patch cords.
Patch Panel: A cross-connect system of mateableconnectors that facilitates administration.
Pathway: A facility for the placement oftelecommunications cable. Synonym: Raceway.
Pay-Off: The process of feeding a cable or wirefrom a bobbin, reel or other package.
Percent Plating: Quantity of plating on aconductor expressed as a percentage byweight.
Percentage Conductivity: Conductivity of amaterial expressed as a percentage of that ofcopper.
Periodicity: The uniformly spaced variations in theinsulation diameter of a transmission cable thatresult in reflections of a signal, when itswavelength or a multiple thereof is equal to thedistance between two diameter variations.
Permittivity: See Dielectric Constant.Phase: An angular relationship between waves.Phase Shift: A change in the phase relationship
between two alternating quantities.Photodetector (Receiver): Converts light energy
to electrical energy.Pick: Distance between two adjacent crossover
points of braid filaments. The measurement inpicks per inch indicates the degree of coverage.
Picofarad: One-millionth of one-millionth of afarad. A micromicrofarad or picofarad(abbreviation pf). (See F).
Pigtail Wire: Fine-stranded, extra-flexible, rope-lay lead wire attached to a shield for terminatingpurposes.
Pitch: In flat cable, the nominal distance betweenthe index edges of two adjacent conductors.
Pitch Diameter: Diameter of a circle passingthrough the center of the conductors in any layerof a multiconductor cable.
Plain Conductor: A conductor consisting of onlyone metal.
Plain Weave: A weave used on woven cables.Threads between the wires act as binders andgive the cable lateral stiffness and linearflexibility. Also called Standard and Squareweave.
Planetary Cabler: A cabler capable of layingdown any number of shielded, overbraided orjacketed singles, pairs, called groups, or anycombination of them in sequence.
Planetary Twister: A twisting machine whosepayoff spools are mounted in rotating cradlesthat hold the axis of the spool in a fixed directionas the spools are revolved so no twist is built upin each wire.
Plastic Deformation: Change in dimensionsunder load that is not recovered when the load isremoved.
Plasticizer: A chemical agent added to plastics tomake them softer and more pliable.
Plenum: The air return path of a central airhandling system, either ductwork or open spaceover a suspended ceiling.
Plenum Cable: Cable approved by a recognizedagency such as UL for installation in plenumswithout the need for conduit.
Plug: The part of the two mating halves of aconnector which is moveable when not fastenedto the other mating half.
Ply: The number of individual strands or filamentstwisted together to form a single thread.
Point-to-Point: A type of connection establishedbetween two specific locations, as between twobuildings.
Point-to-Point Wiring: An interconnectingtechnique wherein the connections betweencomponents are made by wires routed betweenconnecting points.
Polarization: The orientation of a flat cable or arectangular connector.
Polishing: (fiber optic) Act of smoothing ends offibers to an ‘optically smooth’ finish, generallyusing abrasive.
Polyester: Polyethylene terephthalate, usedextensively as a moisture-resistant cable corewrap.
Polyethylene: A thermoplastic material havingexcellent electrical properties.
Polyhalocarbon: A general name for polymerscontaining halogen atoms. The halogens arefluorine, chlorine, bromine and iodine.
Polymer: A material of high molecular weightformed by the chemical union of monomers.
Polyolefin: Any of the polymers and copolymersof the ethylene family of hydrocarbons.
Polypropylene: A thermoplastic similar topolyethylene but stiffer and having highersoftening point (temperature); excellent electricalproperties.
Polyurethane: Class of polymers known for goodabrasion and solvent resistance (may be appliedin solid or cellular form).
Porosity: Multiple voids in an insulation cross-section.
Potting: The sealing of a cable termination orother component with a liquid which thermosetsinto an elastomer.
Power Cables: Cables of various sizes,construction and insulation, single or multi-conductor designed to distribute primary powerto various types of equipment.
Power Factor: The ratio of resistance toimpedance. The ratio of the actual power of analternating current to apparent power.Mathematically, the cosine of the angle betweenthe voltage applied and the current resulting.
Pre-Bond: Stranded wire which has been fused,topcoat-tinned or overcoat-tinned.
Prewiring: Wiring installed• Before walls are enclosed or finished. • In anticipation of future use or need.
Primary: The transformer winding which receivesthe energy from a supply circuit.
Primary Insulation: The first layer of non-conductive material applied over a conductor,whose prime function is to act as electricalinsulation.
Primary Protection: The minimum protectionrequired on all exposed facilities to comply withNEC requirements.
Primary Wiring: A printed circuit intended toprovide point-to-point electrical connections.
Programming: Ability to select various circuitpatterns by interconnecting appropriatecontacts on one side of a connector plug orpanel.
Propagation Delay: Time delay between inputand output of signal.
209
GlossaryElectronics Technical Information
Propagation Time: Time required for a wave totravel between two points on a transmission line.
Protocol: A set of rules for communicating.Proximity Effect: Nonuniform current distribution
over the cross-section of a conductor caused bythe variation of the current in a neighboringconductor.
Pull Box: A device to access a raceway used tofacilitate placing of wire or cables.
Pull Cord/Pull Wire: Cord or wire placed within araceway and used to pull wire and cable throughthe raceway.
Pull Strength: See Pull Tension.Pull Tension: The maximum pulling force that can
be safely applied to a cable without damage.Pulling Eye: A device used to pull cable into or
from a duct.Pulse: Energy which changes abruptly from an
intensity to another. May be light energy orelectrical energy.
Pulse Cable: A type of coaxial cable constructedto transmit repeated high-voltage pulses withoutdegradation.
Polyvinyl Chloride (PVC): A general-purposethermoplastic widely used for wire and cableinsulations and jackets.
Quad: A series of four separately insulatedconductors, generally twisted together in pairs.Also, a series-parallel combination of transistorswith increased reliability because failure of onetransistor will not disable the entire circuit.
Quadders: Three-bay machines which can twistfour wires together and cable braided andshielded wires with varying lay lengths.
Raceway: Any channel designed for holding wiresor cables, e.g. conduit, electrical metallic tubing,sleeves, slots, underfloor raceways, cellularfloors, surface raceways, lighting fixtureraceways, wireways, cable troughs, busways,auxiliary gutters and ventilated flexiblecableways. Synonym: Pathway.
Rack: See: Cable Rack.Radio Frequency: The frequencies in the
electromagnetic spectrum that are used for radiocommunications.
Random Winding: A winding in rotatingequipment wherein the wires do not lie in aneven pattern.
Reactance: The opposition offered to the flow ofalternating current by inductance or capacitanceof a compound or circuit.
Red Plaque: A powdery, brown-red growth foundon silvercoated copper conductors and shieldbraids.
Redraw: The consecutive drawing of wire througha series of dies to reach a desired wire size.
Reducing Joint: A joint between two lengths ofcable where the conductors are not the samesize.
Reel: A revolvable flanged device made of woodor metal, used for winding flexible metal wire orcable.
Reflection: (fiber optic) Change in direction of alight wave or ray.
Reflection Loss: The part of a signal which is lostdue to reflection of power at a line discontinuity.
Refraction: (fiber optic) The bending of lightwavesor rays as they go from one material to anotherdue to the difference in velocities in thematerials.
Reinforced Sheath: The outermost covering of acable that has cable sheath constructed inlayers with the addition of a reinforcing material,usually a braided fiber, molded in place betweenlayers.
Remanence: The magnetic induction that remainsin a magnetic circuit after the removal of anapplied magnetomotive force.
Repeater: A device which consists of atransmitter and a receiver or transmitter, used toregenerate a signal to increase the systemtransmission length.
Resistance: A measure of the difficulty in movingelectrical current through a medium whenvoltage is applied. It is measured in Ω.
Resistive Conductor: A conductor with highelectric resistance.
Retractile Cord: A cord having specially treatedinsulation or jacket so that it will retract.
Return Wire: A ground wire or the negative wire ina direct-current circuit.
Ribbon Cable: A flat cable of individually insulatedconductors lying parallel and held together bymeans of adhesive or woven textile yarn.
Ridge Marker: One or more ridges runninglaterally along the outer surface of a plastic-insulated wire for purposes of identification.
Rigid Bay: Cabling equipment that maintainscomponent sequence, and can produce cableswith distinct layers.
Rigid Coaxial Cable: Nonflexible coaxial cable,usually a metal tube armored coaxial cable.
Ring Tongue: A solderless terminal that connectswire to a stud.
Ringing Out: Locating or identifying specificconductive paths by passing current throughselected conductors.
Rip-Cord: 1.) Two or more insulated conductors ina parallel configuration which may be separatedto leave the insulation of each conductor intact.2.) A small filament cord used to rip through theouter cable sheath.
Rope Concentric: A group of standardconductors assembled in a concentric manner.
Rope Lay Conductor: A conductor composed ofa central core surrounded by one or more layersof helically laid groups of wires.
Rope Unilay: A group of stranded conductorsassembled in a unilay manner.
Round Wire Shields: Shields constructed frombare, tinned or silver-plated copper wire thatinclude braided, spiral and reverse spiral.
Routers: A device that determines how to forwarda packet toward its destination, based on tablesthat indicate the costs, congestion status andother factors associated with possible routes.Also called a level 3 relay or an intermediatesystem.
Rubber (Wire Insulation): Term used to describewire insulations made of thermosettingelastomers; occurs naturally or may be madesynthetically.
Rulan®: DuPont’s trade name for their flame-retardant polyethylene insulating material.
Screen: A shield placed over the entire core.Secondary Insulation: A nonconductive material
that protects the conductor against abrasionand provides a second electrical barrier.
Segmental Conductor: A stranded conductorconsisting of three or more stranded conductingelements, each element having approximatelythe shape of the sector of a circle, assembled togive a substantially circular cross-section.
Selenium Cure: Process used to cure neopreneand rubber jacketed wires and cables.
Self-Extinguishing: Characteristic of a materialwhose flame is extinguished after the ignitingflame source is removed.
Semi-Conducting Jacket: A jacket having asufficiently low resistance so that its outersurface can be kept at substantially groundpotential.
Semi-Rigid: A cable containing a flexible innercore and a relatively inflexible sheathing.
Semi-Solid: An insulation cross-section having apartially open space between the conductor andthe insulation perimeter.
Separator: A layer of insulating material which isplaced between a conductor and its dielectricbetween a cable jacket and the components itcovers, or between various components of amultiple-conductor cable.
Series Circuit: A circuit in which the componentsare arranged end to end to form a single path forcurrent.
Serve: A filament or group of filaments such asfibers or wires, wound around a central core.
Serving: A wrapping applied over the core of acable or over a wire.
Sheath: See Cable Sheath.Shield: In cables, a metallic layer placed around a
conductor or group of conductors to preventelectrostatic or electromagnetic interferencebetween the enclosed wires or external fields.
Shield Coverage: Amount of outer cable coveredby the shielding material.
Shield Effectiveness: The ability of a shield toscreen out undesirable signals.
Shielded Line: A transmission line whoseelements confine propagated radio waves to anessentially finite space inside a tabularconducting surface called the sheath, thuspreventing the line from radiating radio waves.
Shielded-Type Cable: A cable in which thesurface of the insulation is at ground potential.
Shunt Wire: A conductor joining two parts of anelectric circuit to divert part of the current.
Signal: A current used to convey information,either digital, analog, audio or video.
Silicone: A material made from silicon andoxygen. Can be in thermosetting elastomer orliquid form. The thermosetting elastomer form isnoted for high heat resistance.
Silicone Treating: A silicone liquid treatmentapplied to insulated conductors to allow for easyjacket stripping.
Sine Wave: A wave that can be expressed as thesine of a linear function of time, or space orboth.
Single-ended: Unbalanced, such as groundingone side of a circuit or transmission line.
Single-Faced Tape: Fabric tape finished on oneside with a rubber or synthetic compound.
Single Mode Fiber: A fiber wave guide in whichonly one mode will propagate. The fiber has avery small core diameter of approximately 8mm.It permits signal transmission at extremely highbandwidths and is generally used with laserdiodes.
210
GlossaryTechnical Information Electronics
Sizing: Applying a material to a surface to fillpores.
Skeleton Braid: Widely separated braid of fibercopper or steel, used to hold core together, forreinforcing jacket or for shielding.
Skew Rays: A ray that does not intersect the fiberaxis. Generally, a light ray that enters the fibercore at a very high angle.
Skim Tape: Filled tape coated on one or bothsides with a thin film of uncured rubber orsynthetic compound to produce a coatingsuitable for vulcanization.
Skin Effect: The tendency of alternating current,as its frequency increases, to travel only on thesurface of a conductor.
Sleeve: A braided, knitted or woven tube usedover wires or components as insulation tubing.Also called Sleeving.
Solid Conductor: A conductor consisting of asingle wire.
Source Coupling Loss: (fiber optic) Loss of lightintensity as light from source passes into fiber.
Space, Telecommunications: An area used forhousing the installation and termination oftelecommunications equipment and cable, e.g.telecommunications closets, work areas andmanhole/handholes.
Span: (1.) In flat conductors, distance betweenthe reference edge of the first and the lastconductor. (2.) In round conductors, distancebetween centers of the first and last conductors.(3.) In aerial cable, the distance between poles orsupport clamps.
Spark Test: A test designed to locate pin-holes inthe insulation of a wire or cable by application ofa voltage for a very short period of time while thewire is being drawn through the electrode field.
Specific Gravity: The ratio of the density (massper unit volume) of a material to that of water.
Spectral Bandwidth: The difference betweenwavelengths at which the radiant intensity ofillumination is half its peak intensity.
Spectral Response: (fiber optic) The response ofa detector (or a system) over differentwavelengths.
Spectrum: Frequencies that exist in a continuousrange and have a common characteristic.
Speed of Light (c): 2.998 x 108 meters persecond.
Spiral Shield: A metallic shield of fine-strandedwires applied spirally rather than braided.
Spiral Stripe: A color-coding stripe appliedhelically to the surface of an insulated wire orcable.
Spiral Wrap: The helical wrap of a tape or threadover a core.
Splice: A joining of conductors, generally fromseparate sheaths.
Splice Closure: A device used to protect a cableor wire splice.
Spread Spectrum: A modulation technique formultiple access, or for increasing immunity tonoise and interference.
Standing Wave: The stationary pattern of wavesproduced by two waves of the same frequencytraveling in opposite directions on the sametransmission line.
Standing Wave Ratio (SWR): In a transmissionline, waveguide, or analogous system, a figure ofmerit used to express the efficiency of thesystem in transmitting power.
Star Topology: A topology in which eachtelecommunications outlet/connector is directlycabled to the distribution device.
Stay Cord: A component of a cable used toanchor the cable ends at their points oftermination and to keep any pull of the cablefrom being transferred to the electricalconnections.
Step Index Fiber: (fiber optic) A multimode fiberconsisting of a core of uniform refractive indexsurrounded by cladding of slightly lowerrefractive index.
Strand: One of the wires of any strandedconductor.
Strand Lay: The distance of advance of onestrand of a spirally stranded conductor, in oneturn, measured axially.
Stranded Conductor: A conductor composed ofgroups of wires twisted together.
Strap: Square- or rectangular-section bareconductor manufactured and used in coil form.
Strip: To remove insulation from a cable.Structural Return Loss: Backward reflected
energies from uneven parts of the cablestructure causing impedance variations aretermed structural return loss.
Surface Resistivity: The resistance of a materialbetween two opposite sides of a unit square ofits surface. It is usually expressed in Ω.
Surge: A temporary and relatively large increase inthe voltage or current in an electric circuit orcable. Also called Transient.
Suspended Ceiling: See False Ceiling.Sweep-test: Pertaining to cable, the frequency
response is verified by generating an rf voltagewhose frequency is swept repeatedly through agiven frequency range at a rapid constant ratewhile the cable response is observed.
Take-Up: The process of accumulating wire orcable onto a reel, bobbin or some other type ofpack. Also, the device for pulling wire or cablethrough a piece of equipment or machine.
Tank Test: A voltage dielectric test in which thetest sample is submerged in water and voltage isapplied between the conductor and water asground.
Tape: A relatively narrow woven or cut strip offabric, paper or film material.
Tape Cable: A form of multiple conductorconsisting of parallel metal strips imbedded ininsulating material.
Tape Wrap: A spirally applied tape over aninsulated or uninsulated wire.
Taped Insulation: Insulation of helically woundtapes applied over a conductor or over anassembled group of insulated conductors.
Taping: Process of insulating continuous length,large diameter wires with tape of non-extrudablematerials.
TB: Terminal BlockTear Strength: The force required to initiate or
continue a tear in a material under specifiedconditions.
Teflon®: DuPont company trade name forfluorocarbon resins. FEP, PFA and TFE aretypical materials.
Tefzel®: DuPont trade name for a fluorocarbonmaterial typically used as a wire wrap insulation.
Telecommunications: The communication ofinformation over some distance, includinginterbuilding and intrabuilding distances.
Telecommunications Closet: See Closet,Telecommunications.
Telecommunications Entrance Facility: SeeEntrance Facility, Telecommunications.
Telecommunications Entrance Point: SeeEntrance Point, Telecommunications.
Telecommunications Entrance Room or Space:See Entrance Room or Space,Telecommunications.
Telecommunications Equipment Room: SeeEquipment Room, Telecommunications.
Telecommunications Grounding Busbar: Acommon point of connection fortelecommunications system and bonding toground, which is located in thetelecommunications closet or equipment room.
Telecommunications Infrastructure: SeeInfrastructure, Telecommunications.
Telecommunications Outlet/Connector: SeeOutlet/Connector, Telecommunications.
Telemetry Cable: Cable used for transmission ofinformation from instruments to the peripheralrecording equipment.
Temperature Rating: The maximum temperatureat which an insulating material may be used incontinuous operation without loss of its basicproperties.
Tensile Strength: The pull stress required tobreak a given specimen.
Tension Member: A member included in a fibercable to add tensile strength.
Terminal: (1) A point at which information mayenter or leave a communications network;(2) the input-output associated equipment; or(3) a device by means of which wires may beconnected to each other.
Termination Hardware: This term is outmodedsee Connecting Hardware.
Test Lead: A flexible, insulated lead wire used formaking tests, connecting instruments to a circuittemporarily or for making temporary electricalconnections.
Textile Braid: Any braid made from threads ofcotton silk, or synthetic fibers.
Thermal Aging: Exposure to a thermal conditionor programmed series of conditions forpredescribed periods of time.
Thermocouple Lead Wire: An insulated pair ofwires used from the couple to a junction box.
Thermoplastic: A material which softens whenheated and becomes firm on cooling.
Thermoset: A material which hardens or setswhen heat is applied, and which, once set,cannot be resoftened by heating. Theapplication of heat is called “curing.”
Three-Phase Current: Current delivered throughthree wires, with each wire serving as a return forthe other two.
Three-Phase Three-Wire System: An alternatingcurrent supply system comprising threeconductors over which three-phase power issent.
Three-Wire System: A d-c or single-phase a-csystem comprising three conductors, one ofwhich is maintained at a potential midwaybetween the potential of the other two.
Tin Overcoat (TOC): Tinned copper wire,stranded, then coated with pure tin.
211
GlossaryElectronics Technical Information
Tinsel Wire: A low-voltage stranded wire, witheach strand a very thin conductor ribbon spirallywrapped around a textile yarn.
Topcoat: Bare (untinned) copper wire, strandedthen coated with pure tin.
Topology: The physical or logical arrangement ofa telecommunications system.
Tracer: A means of identifying polarity.Transducer: A device for converting mechanical
energy to electrical energy.Transfer Impedance: The ratio of the source
voltage of the wires inside the cable to the shieldcurrent of the cable or connectorized cableassembly.
Transition Point: A location in the horizontalcabling where flat undercarpet cable connects toround cable.
Transmission: Transfer of electric energy fromone location to another through conductors orby radiation or induction fields.
Transmission Cable: Two or more transmissionlines. See Transmission Line.
Transmission Line: An arrangement of two ormore conductors or a wave guide used totransfer signal energy from one location toanother.
Transmission Loss: The decrease or loss inpower during transmission of energy from onepoint to another. Usually expressed in decibels.
Transmission Media: The various types of wireand optical fiber cable used for transmittingvoice or data signals. Typically, wire cableincludes twisted pair, coaxial and twinaxial.Optical fiber cable includes single, dual, quad,stranded and ribbon (Al).
Transmitter: The electronic package that injectsan electrical signal or light signal over thetransmission medium.
Transparent: (fiber optic) Transmitting rays of lightso that objects can be seen through thematerial.
Transposition: Interchanging the relative positionsof wires to neutralize the effects of induction toor from other circuits or, to minimize interferencepickup by the lead-in during reception.
Tray Cable: A factory-assembled multiconductoror multipair control cable approved under theNational Electrical Code for installation in trays.
Triaxial: A three-conductor cable with oneconductor in the center, a second circularconductor shield concentric with the first, andthird circular conductor shield insulated fromand concentric with the first and second, usuallywith insulation, and over a braid or impervioussheath overall.
Triboelectric Noise: Noise generated in ashielded cable due to variations in capacitancebetween shielding and conductor as the cable isflexed.
Triple Cable: A cable composed of three insulatedsingle conductors and one bare conductor, alltwisted together. It may or may not have acommon covering of binding.
True Concentric: A cable in which eachsuccessive layer has a reversed direction of layfrom the preceding layer.
Trunk Cable: See Feeder Cable.Tubing: A tube of extruded non-supported plastic
material.
Twin Cable: A pair of insulated conductorstwisted, sheathed or held together mechanicallyand not identifiable from each other in acommon covering.
Twin Coaxial: A configuration containing twoseparate, complete coaxial cables laid parallel ortwisted around each other in one complex.
Twin Line: A transmission line which has a solidinsulating material, in which the two conductorsare placed in parallel to each other.
Twinner: A device for twisting together twoconductors.
Twisted Pairs: A cable composed of two smallinsulated conductors twisted together without acommon covering.
Unbalanced Line: A transmission line in whichvoltages on the two conductors are unequal withrespect to ground.
Unidirectional Concentric Stranding: Astranding where each successive layer has adifferent lay length, thereby retaining a circularform without migration of strands from one layerto another.
Unidirectional Stranding: A term denoting that ina stranded conductor, all layers have the samedirection of lay.
Unilay Strand: A conductor constructed with acentral core surrounded by more than one layerof helically-laid wires, with all layers having acommon length and direction of lay.
Velocity of Propagation (VP): The speed of anelectrical signal down a length of cablecompared to speed in free space expressed as apercent. It is the reciprocal of the square root ofthe dielectric constant of the cable insulation.
Volt: A unit of electromotive force.Voltage: The term most often used in place of
electromotive force, potential difference orvoltage drop to designate the electric pressurethat exists between two points and is capable ofproducing a current when a closed circuit isconnected between two points.
Voltage Drop: The voltage developed across acomponent or conductor by the current in theresistance or impedance of the component orconductor.
Voltage Rating: The highest voltage that may becontinuously applied to a wire in conformancewith standards or specifications.
Voltage Standing Wave Ratio (VSWR): The ratioof the maximum effective voltage to theminimum effective voltage measured along thelength of a mis-matched radio frequencytransmission line.
Volume Resistivity (Specific InsulationResistance): The electrical resistance betweenopposite faces of a 1 cm. cube of insulatingmaterial, commonly expressed in Ω/centimeter.
Vulcanization: A chemical reaction in which thephysical properties of an elastomer are changedby reacting it with sulfur or other cross-linkingagents.
Wall Thickness: The thickness of the appliedinsulation or jacket.
Water Absorption: A test to determine the waterabsorbed by a material after a given immersionperiod.
Waterblocked Cable: A cable constructed withno internal voids in order to allow no longitudinalwater passage under a given pressure.
Watt: A unit of electric power.Wave Form: A graphical representation of a
varying quantity. Usually, time is represented onthe horizontal axis, and the current or voltagevalue is represented on the vertical axis.
Wave Length: The distance, measured in thedirection of propagation, of a repetitive electricalpulse or waveform between two successivepoints that are characterized by the same phaseof vibration.
Wicking: The longitudinal flow of a liquid in a wireor cable due to capillary action.
Wire: A conductor, either bare or insulated.Wire and Cable Marker: Device for identification
marking of wire and cable.Wire and Cable Tying, Clamping, and
Harnessing Devices: Tying tapes, lacing cordsand flexible sleevings which are used for wireand cable bundling, harnessing and holding.Other devices include plastic ties or clamps,spiral-cut plastic tubing and plastic U-shapedtrays or ducts.
Wire and Lead Cutters: Tools for cutting thatrange from plier-type cutters to semiautomaticor fully automatic machines integrated with otherwire processing operations such as stripping,forming and terminating.
Wire Gauge: A system of numerical designation ofwire sizes.
Wire Nut: A closed-end splice that is screwed oninstead of crimped.
Wire Wrapped Connection: A solderlessconnection made by wrapping bare wire arounda square or rectangular terminal with a power orhand tool.
Wire Wrapping Tools: Portable electric tools andautomatic stationary machines used to makesolderless wrapped connections of wires toterminals.
Wiring Closet: See Telecommunications Closet.Work Area (Work Station): A building space
where the occupants interact withtelecommunications terminal equipment.
Wrapper: An insulating barrier applied as a sheetor tape wrapped around a coil periphery.
Yield Strength: The minimum stress at which amaterial will start to physically deform withoutincrease in load.
Zytel®: DuPont’s trade name for nylon resins.
Sections of this glossary are reprinted with permissionfrom December, 1985 Issue of ELECTRONICS copyright1985. Lake Publishing Corporation, 17730 W. PetersonRd., Libertyville, IL 60048-0159 USA. Permission toreprint granted to the General Cable Corporation.No additional reproduction of this wire and cable glossaryallowed without written permission.
212
Technical Information Electronics
Abbreviations & Acronyms
A-D: Analog to digital conversionac: Alternating currentAC: Armored Cable, NEC Article 333 Cable
DesignationAC0: Analog Central OfficeACR: Attenuation to Crosstalk RatioADO: Auxiliary Disconnect OutletAER: AerialAF: Audio frequencyAIA: American Institute of ArchitectsALPETH: An aerial telephone cable having an alu-
minum shield and polyethylene jacketALS: A type of cable consisting of insulated con-
ductors enclosed in a continuous, closely fittingaluminum tube
ALVYN: An indoor, riser rated telephone cable hav-ing an aluminum shield and vinyl jacket (PVC)
AM: Amplitude ModulationANSI: American National Standards InstituteARPANET: Advanced Research Projects Agency
NetworkASCII: American Standard Code for Information
InterchangeASME: American Society of Mechanical EngineersASP: A filled, direct burial telephone cable used in
areas subject to rodent attack. It consists of afilled cable core, corrugated aluminum shield,corrugated steel tape, flooding compound andpolyethylene jacket.
ASTA: United Kingdom approval agencyASTM: American Society for Testing and MaterialsAWG: American Wire GaugeAWM: Appliance wiring materialB & S Gauge: See American Wire Gauge (AWG)B or BUR: BuriedAWM: Appliance wiring materialBCF: Billion Conductor FeetBEF: Building Entrance FacilityBER: Bit Error RateBIC: Building Industry ConsultantBICSI: Building Industry Consulting Service
InternationalBISDN: Broadband Integrated Services Digital
NetworkBTU: British Thermal UnitCA: CableCATV: (1) Community Antenna Television; Cable
Access Television (2) CATV Cable, NEC Article820 Cable Designation
CATVP: CATV Plenum Cable, NEC Article 820Cable Designation
CATVR: CATV Riser Cable, NEC Article 820 CableDesignation
CATVX: CATV Limited Use Cable, NEC Article 820Cable Designation
CB: Citizens bandC-C: Conductor to conductor capacitanceCCITT: The International Telegraph and Telephone
Consultative CommitteeCCTV: Closed-circuit televisionCDDI: Copper Distributed Data InterfaceCDF: Central Distribution FrameCDO: Community Dial OfficeCEBEC: Belgium approval agency; Commite
Electrotechnique Belge Service de la MarqueCEE: European standards agency; International
Commission on Rules for the Approval ofElectrical Equipment
CEN: European Committee for StandardizationCENELEC: European Committee for
Electrotechnical StandardizationCFC: Communications Flat Cableckt: CircuitCLT or CLOS: ClosetCL2: Class 2 Circuit Cable, NEC Article 725 Cable
DesignationCL2P: Class 2 Circuit Plenum Cable, NEC Article
725 Cable DesignationCL2R: Class 2 Circuit Riser Cable, NEC Article 725
Cable DesignationCL2X: Class 2 Circuit Limited Use Cable, NEC
Article 725 Cable DesignationCL3: Class 3 Circuit Cable, NEC Article 725 Cable
DesignationCL3P: Class 3 Circuit Plenum Cable, NEC Article
725 Cable DesignationCL3R: Class 3 Circuit Riser Cable, NEC Article 725
Cable DesignationCL3X: Class 3 Circuit Limited Use Cable, NEC
Article 725 Cable DesignationCM: Communications Cable, NEC Article 800 Cable
DesignationCMA: Circular Mil AreaCMP: Communication Cable Plenum, NEC Article
800 Cable DesignationCMR: Communications Cable Riser, NEC Article
800 Cable DesignationCMX: Communications Limited Use Cable, NEC
Article 800 Cable DesignationCO: Central Officecodec: Coder decoderCOE: Central Office EquipmentCOS: Cooperation for Open SystemsCOSINE: Cooperation for Open Systems
Interconnection Network in EuropeCOT: Central Office TerminalCPC: Customer Premises CommunicationCPE: (1) Chlorinated Polyethylene (2) Customer
Premises Equipment or Customer ProvidedEquipment
CPU: Central Processing UnitCRT: Cathode Ray TubeCSMA/CD: Carrier Sense Multiple Access/
Collision DetectionCSPE: Chlorosulfonated PolyethyleneCTR: Certified Test ReportCV: Continuous vulcanizationD-A: Digital to analog conversionDAF: Dedicated Access FacilitydB: DecibelDBS: Direct Broadcast Satellitedc: Direct currentDCE: Data Circuit-Terminating EquipmentDCO: Digital Central OfficeDCR: Direct Current ResistanceDD: Distribution Designer or Distribution DeviceDEMARC: Demarcation pointDEMKO: Approval agency of DenmarkDGM: Data Grade MediumDISA: Defense Information Systems Agency
(formerly DCA)DISI: Directory Information Services InfrastructureDIST: DistrictDRT: Plastic range and dryer cord (CSA)DTE: Data Terminal EquipmentDVD: Digital Versatile Disc
DW: Distribution WireE: Symbol for voltage. Usually used to represent
direct voltage or the effective (root-mean-square)value of an alternating voltage
EFTS: Electronic funds transfer systemEIA: Electronic Industries AssociationEMF: Electromotive ForceEMI: Electromagnetic InterferenceEMT: Electric Metallic TubingEP: Entrance pointEPDM: Ethylene-propylene-diene monomer rubberEPOS: Electronic Point-Of-SaleEPR: Ethylene-propylene rubberER: Equipment roomESS: Electronic Switching SystemESTA: Australian approval agency; Electricity Trust
of South AustraliaETPC: Electrolytic Tough Pitch CopperETV: Educational TelevisionE/W: Equipped WithEX or EXT: ExtensionEXCH: Exchangef: FrequencyFAA: Federal Aeronautics AdministrationFCC: (1) Federal Communications Commission (2)
Flat Conductor Cable, NEC Article 328 CableDesignation
FDDI: Fiber Distributed Data InterfaceFDM: Frequency-Division MultiplexingFDR: FeederFEP: Fluorinated ethylene propyleneFEXT: Far End CrosstalkFI: Approval agency of Finland; Electrical
InspectorateFIPS PUB: Federal Information Processing
Standard PublicationFM: Frequency modulationFOCIS: Fiber Optic Connector Intermateability
StandardFOTP: Fiber Optic Test ProcedureFOTS: Fiber Optics Transmission SystemFPL: Power Limited Fire Protective Signaling Circuit
Cable, NEC Article 760 Cable DesignationFPLP: Power Limited Fire Protective Signaling
Circuit Plenum Cable, NEC Article 760 CableDesignation
FPLR: Power Limited Fire Protective SignalingCircuit Riser Cable, NEC Article 760 CableDesignation
FR-1: A flammability rating established byUnderwriter's Laboratories for wires and cablesthat pass a specially designed vertical flame test
freq: FrequencyFRICC: Federal Research Internet Coordinating
Committee (now FNC)FRPE: Flame Retardant Polyethyleneft: FootFTP: Fire Transfer Protocolga: GaugegHZ: Gigahertzgrd: GroundGTO: Gas tube sign and oil-burner ignition cable.
5,000V-15,000V.H: Designation for intensity of magnetic energyhc: Handset combination (single-line telephone)HC: Horizontal cross-connecthck: Handset combination; key (six-button
telephone)
213
Electronics Technical Information
Abbreviations & Acronyms
HDPE: High Density PolyethyleneHF: High Frequencyhh: HandholeHi-Pot: A test designed to determine the highest
voltage that can be applied to a conductor without breaking through the insulation.
HPD: Rubber- and asbestos-insulated heater cord.No braid on individual conductors but with braidoverall. Also made with neoprene insulation andno asbestos or PVC/NBC.
HPN: Two-conductor, neoprene-insulated heatercord. Parallel construction. For use in damp locations.
HSJ: Same as type HS but with #18, #16 and #14conductors and differing thickness of jacket.
HVAC: Heating, ventilation and air conditioningHz: Hertzi: Symbol used to designate currentIC: Intermediate cross-connectICEA: Insulated Cable Engineers AssociationIDC: Insulation Displacement ConnectorIEC: Internation Electrotechnical CommissionIEEE: Institute of Electrical and Electronics
EngineersIGS: Integrated Gas Spacer Cable, NEC Article
325 Cable DesignationIMSA: International Municipal Signal Associationin: InchIRSG: Internet Research Steering GroupIRTF: Internet Research Task ForceIS: International StandardISA: Instrument Society of AmericaISDN: Integrated Services Digital NetworkISO: International Organization for StandardizationISOC: Internet SocietyITCO: Independent Telephone CompanyITU-T: International Telecommunications Union -
Telecommunications Standardization SectionIW (C): Inside Wiring (cable)J: JouleKEMA KEUR: Approval agency of the Netherlandskft: An abbreviation for 1000 ft.kHz: KilohertzKilo: A numerical prefix denoting 1000 (103)km: KilometerKTS: Key Telephone ServicekV: KilovoltkVA: Kilovolt AmperekW: KilowattLAN: Local Area NetworkLASER: Light Amplification by Stimulated
Emission of RadiationLATA: Local Access Transport Arealbf: Pound forceLBO: Line BuildoutLDPE: Low Density PolyethyleneLEC: Local Exchange CarrierLED: Light-Emitting DiodeLLDPE: Linear Low Density PolyethyleneLOCA: Loss of Coolant Accidentlocap: Low-capacitance, low-loss paired cableMAC: Moves, Adds and ChangesMAP: Manufacturing Automation ProtocolMATV: Master Antenna TelevisionMbps: Megabits per secondMC: (1) main cross-connect (2) Metal Clad Cable,
NEC Article 334 Cable Designation
MCM: One thousand circular milsMDF: Main Distribution FrameMDPE: Medium Density PolyethyleneMeg or Mega: A numerical prefix denoting
1,000,000 (106)M/G: Motor/Generator SetMH: ManholeMho: The unit of conductivity. The reciprocal of an
ohm.MHz: MegahertzMI: Mineral Insulated Cable, NEC Article 330
Cable DesignationMicro: A numerical prefix denoting one-millionth
(106)MIL STD: Military StandardMILNET: Military NetworkMLT: Multi-Level Thresholdmm: MillimeterModem: Modulator demodulatorMP: Multi-Purpose Cable, NEC Article 800 Cable
DesignationMPOP: Minimum Point of PresenceMPP: Multi-Purpose Plenum Cable, NEC Article
800 Cable DesignationMPR: Multi-Purpose Riser Cable, NEC Article
800 Cable DesignationMTT: Main Telephone TerminalMTW: Machine Tool WireMV: Medium Voltage Cable, NEC Article 326
Cable DesignationMW: Radio hookup wire with polyvinyl insulation
and plain or nylon jacket or braid, or shield,1000V
N: NewtonNAIC: Network Applications and Information
CenterNASA: National Aeronautics and Space
AdministrationNBR: Natural butadiene-acrylonitrile copolymer
rubberNBS: National Bureau of Standards (now NIST)NEC: National Electrical CodeNEMA: National Electrical Manufacturers
AssociationNEMKO: Approval agency of NorwayNESC: National Electrical Safety CodeNEXT: Near End Crosstalknf: NanofaradNFPA: National Fire Protection AssociationNI: Network InterfaceNID: Network Interface DeviceNIST: National Institute of Standards and
Technology (formerly NBS)NIU: Network Interface Unitnm: NanometerNM & NMC: Non Metallic Sheathed Cable, NEC
Article 336 Cable DesignationNPLF: Non Power-Limited Fire Protective
Signaling Circuit Cable, NEC Article 760 CableDesignation
NPLFP: Non Power-Limited Fire ProtectiveSignaling Circuit Plenum Cable, NEC Article 760Cable Designation
NPLFR: Non Power-Limited Fire ProtectiveSignaling Circuit Plenum Cable, NEC Article 760Cable Designation
NRZ: Non Return to ZeroNRZI: Non Return to Zero Inverted
OC: Optical CarrierODC: Ozone Depleting ChemicalOP: Outside PlantOPE: Outside Plant EngineerOSHA: Occupational Safety and Health
AdministrationOSI: Open Systems InterconnectionOVE: Approval agency of West Germany;
Oesterreichischer Verband fur ElektrotechnikPABX: Private Automatic Branch ExchangePAM: Pulse Amplitude ModulationPAP: A commonly used term for air core (unfilled)
direct burial telephone cable with a corrugatedaluminum shield
PBX: Private Branch ExchangePC: Personal ComputerPCB: Printed Circuit BoardP-FEP: General Cable proprietary dielectric
material used injunction with FEP.PCM: Pulse Code ModulationPCP: A commonly used term for air core (unfilled)
direct burial cable with a corrugated coppershield
PE: Polyethylenepf: PicofaradPFA: PolyfluoroalkoxyPIC: A general term for any type of plastic
insulated telephone cablePico: A numerical prefix denoting one-millionth of
one-millionth (10-12)PL: Private LinesPLSJ: All-rubber, parallel-jacketed, two-
conductor, light-duty cord for pendant or portable use in damp locations. 300V.
PLT: (1) Plant (2) Same as PLSJ except thermo-plastic insulation
PLTC: Power Limited Tray Cable, NEC Article 725Cable Designation
PM: Phase ModulationPOI: Point Of InterfacePOSJ: All-rubber, parallel, light duty rip-cord for
use on lamps and small appliances, 300V, 60°CPOT: Thermoplastic, parallel, light duty rip-cord.
300V, 60°C to 105°C.POTS: Plain Old Telephone Service (colloquial)PP: PolypropylenePR: PairPTFE: PolytetrafluoroethylenePTSS: Passive Transmission Sub-SystemPVC: Polyvinyl ChloridePVDF: Polyvinylidene FluorideR: Symbol for resistanceR-F: Radio-frequencyRCDD: Registered Communication Distribution
DesignerREA: Rural Electrification AdministrationREP: RepairRFQ: Request for QuoteRG/U: General utility grade military coaxial cableRH: Relative humidityRJ-45: A specific pin-point assignment for an eight
position modular telecommunications connector.
RMS: (1) rack mount space (2) Root Mean Squares
214
Technical Information Electronics
Abbreviations & Acronyms
S: Heavy-duty, rubber-insulated portable cord.Stranded copper conductors with separator andindividual rubber insulation. Two or more color-coded conductors cabled with filler, wrappedwith separator and rubber jacketed overall, 600Volts.
SAE: Society of Automotive EngineersSANZ: Standards Association of New ZealandSBR: Styrene Butadiene RubberScTP: Screened Twisted PairSDN: Switched Digital NetworkSE: Service Entrance Cable, NEC Article 338
Cable DesignationSEMKO: Approval agency for SwedenSFTP: Simple File Transfer ProtocolSI: System InternationaleSJ: Junior hard-service, rubber-insulated pendant or
portable cord. Same construction as type S, but 300V. Jacket thickness different.
SJO: Same as SJ, but carolprene, oil-resistant com-pound outer jacket. Can also be made "water-resistant." 300V, 60°C.
SJT: Junior hard service thermoplastic or rubber-insulated conductors with overall thermoplasticjacket, 300V, 60°C to 105°C.
SJTO: Same as SJT but oil-resistant thermo-plastic outer jacket. 60°C.
SMTP: Simple Mail Transfer ProtocolSNA: Systems Network ArchitectureSNM: Shielded Non Metallic Sheathed Cable, NEC
Article 337 Cable DesignationSNMP: Simple Network Management ProtocolSNR: Signal to Noise RatioSO: Hard-service cord, same construction as type
S except oil-resistant carolprene jacket, 600V,60° to 90°C.
SONET: Synchronous Optical NetworkSP-1: All rubber, parallel-jacketed, two-conductor
light-duty cord for pendant or portable use indamp locations. 300V.
SP-2: Same as SP-1, but heavier construction, with or without third conductor for groundingpurposes. 300V.
SP-3: Same as SP-23, but heavier construction forrefrigerators or room air conditioners. 300V.
SPC: Stored Program ControlSPG: Single Point GroundSPT-1: Same as SP-1, except all-thermoplastic.
300V. With or without third conductor for grounding.
SPT-2: Same as SP-2, except all-thermoplastic. 300V. With or without third conductor forgrounding.
SPT-3: Same as SP-3, except all-thermoplastic. 300V. With or without third conductor forgrounding.
SRD: Portable range or dryer cable. Three or fourrubber-insulated conductors with rubber or neoprene jacket, flat or round construction.300V, 60°C.
SRDT: Same as SRD, except all-thermoplasticwith a maximum temperature of 90°C.
SRL: Structural return lossST: Hard-service cord, jacketed, same as type S
except all-plastic construction, 600V, 60°C to 105°C.
STA: Station
STO: Same as ST but with oil-resistant thermo-plastic outer jacket. 600V, 60°C.
STP: Shielded twisted pairSV: Vacuum cleaner cord, two or three-conductor,
rubber-insulated. Overall rubber jacket. For light-duty in damp locations. 300V, 60°C.
SVO: Same as SV except carolprene jacket, 300V,60°C.
SVT: Same as SV except all-plastic construction.With or without third conductor for groundingpurposes only. 300V, 60°C to 90°C.
SW: Station WireSWB: SwitchboardSWR: Standing Wave RatioSYS: SystemTC: (1) Power and Control Tray Cable, NEC Article
340 Cable Designation (2) TelecommunicationsCloset
TCP: Transmission Control ProtocolTDM: Time-Division MultiplexingTEL: TelephoneTELCO: Telephone CompanyTERM: Terminal or terminationTEW: Canadian Standard Association type
appliance wires. Solid or stranded singleconductor, plastic-insulated, 600V, 105°C.
TF: Fixture wire, thermoplastic-covered solid orseven strands. 60°C.
TFE: TetrafluoroethyleneTFF: Same as TF but flexible stranding. 60°C.THHN: 90°C, 600V nylon jacketed building wireTHW: Thermoplastic vinyl-insulated building wire.
Flame-retardant, moisture- and heat-resistant.75°C. Dry and wet locations.
THWN: Same as THW but with nylon jacketoverall. 75°C.
TIA: Telecommunications Industry AssociationTOC: Tin OvercoatTP: Transport ProtocolTP-PMD: Twisted Pair-Physical Medium DependentTPDDI: Twisted Pair Distributed Data InterfaceTSB: Telecommunications System BulletinTT: Telephone TerminalTTB: Telephone Terminal BoardTTY: Text TelephonesTW: Thermoplastic vinyl-jacketed building wire,
moisture-resistant. 60°C.UCC: Uniform Code CouncilUF: Thermoplastic underground feeder and
branch circuit cableUF: Underground Feeder and Branch Circuit
Cable, NEC Article 339 Cable DesignationUG: UndergroundUHF: Ultra High Frequency, 300 to 3,000 MHzUL: Underwriter's Laboratories, Inc.µm: Micron or micrometerUPC: Universal Packaging CodeUPS: Uninterruptible Power SupplyUSE: Underground Service Entrance Cable, NEC
Article 338 Cable DesignationUTE: Approval agency for France; Union
Technique de l'ElectriciteUTP: Unshielded twisted-pairV: VoltVDE: West Germany approval agency
VHF: Very High Frequency, 30 to 300 MHzVP: Velocity of PropagationVSWR: Volume Standing Wave RadioVW-1: A flammability rating established by
Underwriters Laboratories for wires and cablesthat pass a specially designed vertical flametest, (formerly designated FR-1)
W: Symbol for watt or wattageWA: Work areaWP: Waterproof OutletX: Cross-connectXLPE: Crosslinked polyethyleneZ: Symbol for impedance
215
Electronics Technical Information
Hook-Up Wire Product Finder
TEMP.C
6060606060
80808080808080
80/10580/10580/10580/10580/10580/10580/10580/10580/10580/105
105105105105105105105105105105105
VOLTAGE UL UL CSA MIL AWG P/N STRAND TYPE PAGE
1500*3000*5000*5000*
10000*
1000100010001000100010001000
300300300300300300300300300300
600600600600600600600600600600600
—————
———————
1007100710071007100710071007100710071007
10151015101510151015101510151015101510151015
—————
———————
1569156915691569156915691569156915691569
———————————
—————
———————
TR-64TR-64TR-64TR-64TR-64TR-64TR-64TR-64TR-64TR-64
TEWTEWTEWTEWTEWTEWTEWTEWTEWTEWTEW
—————
W-76BW-76BW-76BW-76BW-76BW-76BW-76B
——————————
———————————
2020181818
24222018161412
24242222202018181616
2422222020181816141210
C1326C1319C1320C1321C1318
C7600C7602C7604C7606C7608C7610C7611
C2003C2015C2004C2016C2028C2040C2052C2064C2053C2065
C2100C2101C2117C2102C2118C2103C2119C2104C2105C2106C2107
STRANDEDSTRANDED STRANDED STRANDED STRANDED
STRANDED STRANDED STRANDED STRANDED STRANDED STRANDED STRANDED
SOLIDSTRANDED
SOLIDSTRANDED
SOLIDSTRANDED
SOLIDSTRANDED
SOLIDSTRANDED
STRANDEDSTRANDED
SOLIDSTRANDED
SOLIDSTRANDED
SOLIDSTRANDEDSTRANDEDSTRANDED STRANDED
77777
4444444
2222222222
33333333333
* For Intermittent Duty Only
216
Technical Information Electronics
B - BRAID SHIELD IFB - INDIVIDUAL FLEXFOIL® + FLEXFOIL® /BRAID UJ - UN-JACKETEDC - CAROLPRENE® P - PLENUMF - FLEXFOIL® SHIELD R - RUBBERFB - FLEXFOIL® /BRAID SHIELD S - SPIRAL SHIELDI - INDIVIDUAL FLEXFOIL® SHIELD U - NO SHIELD
Multi-Conductor Cable Product Finder
NO.COND.
STRANDTYPE
AWG 28P/N SHIELD PAGE
AWG 24P/N SHIELD PAGE
AWG 22P/N SHIELD PAGE
AWG 20P/N SHIELD PAGE
AWG 19P/N SHIELD PAGE
AWG 18P/N SHIELD PAGE
AWG 16P/N SHIELD PAGE
AWG 14P/N SHIELD PAGE
AWG 12P/N SHIELD PAGE
1
2
2
3
SOLID
STRANDED
SOLID
STRANDED
SOLID
STRANDED
C6500 B . . . . . .24
C0530 FB . . . . . .43C0939 FB . . . . . .41C6501 B . . . . . . .24
C0740 F . . . . . . .39C1226 S . . . . . .137C1228 F . . . . . .138C1356 U . . . . . .153C2461 U . . . . . . .10C2513 F . . . . . . .17C4152 F . . . . . .176C4216 F . . . . . .180
C0680 FB . . . . . .43C0741 F . . . . . . .39C0951 FB . . . . . .41C2462 U . . . . . . .10C4217 F . . . . . .180
C2515 F . . . . . . .17C2676 B . . . . . . .22C4008 U . . . . .9, 30C4167 F . . . . . .176C4408 U . . .85, 103E1000S U . . . . . .98E1002S U . . .97, 98E1482S U . . . . . .87E2000S F . . . . . .99E2100S F-P . . . .101E2482S S . . . . . .88E3000S U-P . . .100E3482S U-P . . . .89E3542S F-P . . . .90
C0431 U . . . . . .15C0450 F . . . . . . .20C0760 F . . . . . . .40C1322 B . . . . . .139C1362 U . . .97, 153C2514 F . . . . . . .17C2516 F . . . . . . .17C2518 F . . . . . . .19C2520 F . . . . . . .19C2677 B . . . . . . .22C2679 B . . . . . . .23C2882 S . . . . . . .21C3105 U-P . . . .110C3115 U-P . . . .109C3154 F-P . . . .112C3158 F-P . . . .111C4100 U . . . . . .173C4153 F . . . . . .176C4168 F . . . . . .176C4192 F . . . . . .177C4210 F . . . . . .177C6310 UJ . . . . .103C6348 U . . . . . . .11E2002S F . . .85, 99E2102S F-P .84, 101E3002S U-P .85, 100
C4410 U . . . . . .103
C0432 U . . . . . . .15C0451 F . . . . . . .20C0761 F . . . . . . .40C0971 FB . . . . . .42C1335 S . . . . . . .21C2517 F . . . . . . .17C2526 F . . . . . . .17C2678 B . . . . . . .23C3310 F-P . . . .112C4062 U . . . . . . .11C4101 U . . . . . .173C4156 F . . . . . .176C4169 F . . . . . .176C4193 F . . . . . .177E1003S U . . . . . .98E2003S F . . . . . .99E2103S F-P . . . .101E3003S U-P . . .100
C1300 B,R . . . .140
C2509 F . . . . . .146C4311 U . . . . . . . .9
C0433 U . . . . . . .15C0452 F . . . . . . .20C0790 F . . . . . . .40C1302 B,R . .27, 140C1360 U . . . . . .153C1642 B . . . . . . .25C2519 F . . . . . . .19C2524 F . . . . . . .17C2540 F . . . . . . .17C2681 B . . . . . . .23C2888 S . . . . . . .21C3320 F-P . . . .112C3602 U-R . . . . .16C4117 U . . . . . .174C4154 F . . . . . .176C4166 F . . . . . .177C4211 F . . . . . .177C6311 UJ . . . . .103C6351 U . . . . . . .12E1022S U . . . . . .98E2022S F . . . . . .99E2122S F-P . . . .101E3022S U-P . . .100
C2510 F . . . . . .146
C0434 U . . . . . . .15C0453 F . . . . . . .20C0781 F . . . . . . .40C1304 B,R . . . . .27C1332 B . . . . . . .23C1333 F . . . . . .142C1643 B . . . . . . .25C2525 F . . . . . . .17C2528 F . . . . . . .17C3321 F-P . . . .112C3603 U,R . . . . .16C4118 U . . . . . .174C4157 F . . . . . .176C4158 F . . . . . .176C6352 U . . . . . . .12E1023S U . . . . . .98E2023S F . . . . . .99E2123S F-P . . . .101E3023S U-P . . .100
C2754 . . . . . . . . .9
C1201 B,C . . . .141C1301 B,R . . . .140
C0471 U . . . .85, 93C0472 F . . . .85, 94C3060 F-P . . . .111C3110 U-P . . . .109C3167 F-P . .85, 96C3200 U-P . . . . .91C3240 U-P . .85, 95C3260 F-P . . . . .92E1030S U . . . . . .98E1502S U . . .87, 89E2030S F . . . . . .99E2200S F-P . . . .101E2402S U . . . . . .87E2502S F . . .85, 88E3030S U-P . . .100E3502S U-P .85, 89E3602S F-P . .85, 90
C0435 U . . . . . . .15C0454 F . . . . . . .20C1202 B,C . .28, 141C1357 U . . .85, 153C2521 F . . . . . . .19C2534 F . . . . . . .17C2686 B . . . . . . .23C2830 U . . . . . . .11C2892 S . . . . . . .21C3062 F-P . . . .111C3102 U-P . . . .110C3112 U-P . . . .109C3162 F-P . . . .112C4114 U . . . . . .173C4125 U . . . . . .174C4155 F . . . . . .176C4197 F . . . . . .177C4212 F . . . . . .177C5460 U . . . . . .102C6312 UJ . . . . .103C6367 U . . . . . .154E1032S U . . .89, 98E2032S F . . . 96, 99E2202S F-P .84, 101E3032S U-P .85, 100
C3114 U-P . . . .109E1503S U . . . . . .87E2503S S . . . . . .88E3503S U-P . . . .89E3603S F-P . . . .90
C0436 U . . . . . . .15C0455 F . . . . . . .20C1203 B,C . . . . .28C2535 F . . . . . . .17C2787 B . . . . . . .23C2768 S . . . . . . .21C2831 U . . . . . . .12C3064 F-P . . . .111C3120 U-P . . . .109C3164 F-P . . . .112C3190 U-P . . . .110C4126 U . . . . . .174C4159 F . . . . . .176C4198 F . . . . . .177E1033S U . . . . . .98E2033S F . . . . . .99E2203S F-P . . . .101E3033S U-P . . .100
C0473 U . . . .85, 93C0474 F . . . .85, 94C3168 F-P . . .85, 96C3210 U-P . . . . .91C3241 U-P . .85, 95C3270 F-P . . . . .92E1512S U . . . . . .87E2404S U . . . . . .87E2522S F . . . . . .88E3512S U-P . . . .89E3612S F-P . . . .90
C0437 U . . . . . . .15C0456 F . . . . . . .20C1358 U . . . . . .153C1602 B,C . .28, 141C1704 U . . .85, 157C2405 U . . . . . . .13C2536 F . . . . . . .17C2895 S . . . . . . 21C3068 F-P . . . .111C3127 U-P . . . .109C3169 F-P . . . .112C3193 U-P . . . .110C4135 U . . . . . .175C4162 F . . . . . .176C4213 F . . . . . .177E1042S U . . .85, 98E2042S F . . . . . .99E2242S F-P . . . .101E3042S U-P .85, 100
C0438 U . . . . . . .15C0457 F . . . . . . .20C1603 B,C . . . . .28C2406 U . . . . . . .13C2537 F . . . . . . .17C3194 U-P . . . .110C3340 F-P . . . .112C4136 U . . . . . .175C4165 F . . . . . .176C4200 F . . . . . .177E1043S U . . . . . .98E2043S F . . . . . .99E2243S F-P . . . .101E3043S U-P . . .100
C0475 U . . . . . . .94C0491 U . . . . . . .93C3172 F-P . . . . .96C3220 U-P . . . . .91C3224 U-P . . . . .91C3244 U-P . . . . .95C3280 F-P . . . . .92C4163 F . . . . . .176E1522S U . . .85, 87E2406S U . . . . . .87E2532S F . . .85, 88E3522S U-P .85, 89E3622S F-P . .85, 90
C0439 U . . . . . . .15C0458 F . . . . . . .20C1361 U . . . . . .153C1612 B,C . . . . .28C1702 U . . .85, 157C2409 U . . . . . . .13C2538 F . . . . . . .17C3126 U-P . . . .110C4146 U . . . . . .175C4201 F . . . . . .177C4215 F . . . . . .177E1052S U . . .85, 98E2052S F . . . . . .99E2252S F-P . . . .101E3052S U-P .85, 100
C0440 U . . . . . . .15C0459 F . . . . . . .20
C0476 F . . . . . . .94C0492 U . . . . . . .93C3174 F-P . . . . .96C3224 U-P . . . . .91C3246 U-P . . . . .95C3282 F-P . . . . .92C4164 F . . . . . .176E1532S U . . . . . .87E2542S F . . . . . .88E3532S U-P . . . .89E3632S F-P . . . .90
C0441 U . . . . . . .15C0460 F . . . . . . .20C1363 U . . . . . .153C1364 U . . . . . .154C1700 U . . . . . .157C2410 U . . . . . . .13C2539 F . . . . . . .17C3129 U . . . . . .109C4150 U . . . . . .175C4202 F . . . . . .177E1062S U . . .85, 98E2062S F . . . . . .99E2262S F-P . . . .101E3062S U-P .85, 100
217
Electronics Technical Information
B - BRAID SHIELD IFB - INDIVIDUAL FLEXFOIL® + FLEXFOIL® /BRAID UJ - UN-JACKETEDC - CAROLPRENE® P - PLENUMF - FLEXFOIL® SHIELD R - RUBBERFB - FLEXFOIL® /BRAID SHIELD S - SPIRAL SHIELDI - INDIVIDUAL FLEXFOIL® SHIELD U - NO SHIELD
Multi-Conductor Cable Product Finder
NO.COND.
STRANDTYPE
AWG 28P/N SHIELD PAGE
AWG 24P/N SHIELD PAGE
AWG 22P/N SHIELD PAGE
AWG 20P/N SHIELD PAGE
AWG 19P/N SHIELD PAGE
AWG 18P/N SHIELD PAGE
AWG 16P/N SHIELD PAGE
AWG 14P/N SHIELD PAGE
AWG 12P/N SHIELD PAGE
4
5
6
7
8
9
10
12
SOLID
STRANDED
SOLIDSTRANDED
SOLID
STRANDED
SOLIDSTRANDED
SOLID
STRANDED
SOLIDSTRANDED
SOLIDSTRANDED
SOLIDSTRANDED
C0531 FB . . . . . .43C0940 FB . . . . . .41C6502 B . . . . . . .24
C0532 FB . . . . . .43C0941 FB . . . . . .41
C0533 FB . . . . . .43C0942 FB . . . . . .41C6503 B . . . . . . .24
C0534 FB . . . . . .43C0943 FB . . . . . .41
C0535 FB . . . . . .43C0944 FB . . . . . .41C6504 B . . . . . . .24
C0536 FB . . . . . .43C0945 FB . . . . . .41
C0537 FB . . . . . .43C0946 FB . . . . . .41C6505 B . . . . . . .24
C6506 B . . . . . . .24
C0681 FB . . . . . .43C0742 F . . . . . . .39C0952 FB . . . . . .41C2463 U . . . . . . .10C4218 F . . . . . .180
C0682 FB . . . . . .43C0753 F . . . . . . .39C0953 FB . . . . . .41C2464 U . . . . . . .10C4219 F . . . . . .180
C0683 FB . . . . . .43C0743 F . . . . . . .39C0954 FB . . . . . .41C1345 F . . . . . .142C2466 U . . . . . . .10C4220 F . . . . . .180
C0684 FB . . . . . .43C0754 F . . . . . . .39C0955 FB . . . . . .41C2488 U . . . . . . .10C4221 F . . . . . .180
C0685 FB . . . . . .43C0744 F . . . . . . .39C0956 FB . . . . . .41C2465 U . . . . . . .10C4222 F . . . . . .180
C0686 FB . . . . . . .43C0755 F . . . . . . . .39C0957 FB . . . . . . .41C2470 U . . . . . . . .10C4223 F . . . . . . .180
C0687 FB . . . . . .43C0745 F . . . . . . .39C0958 FB . . . . . .41C2471 U . . . . . . .10
C2467 U . . . . . . .10
C4412 U . . .85, 103E1001S U . . . . . .98E1484S U . . . . . .87E2484S F . . . . . .88E3001S U-P . . .100
C0762 F . . . . . . .40C0972 FB . . . . . .42C1118 U . . . . . .102C1337 S . . . . . . .21C1340 F . . . . . .143C2523 F . . . .17, 84C2680 B . . . . . . .23C3106 U-P . . . .110C3116 U-P . . . .109C3155 F-P . . . .112C3159 F-P . . . .111C4063 U . . . . . . .11C4102 U . . . . . .173C4160 F . . . . . .176C4194 F . . . . . .177C5076 U . . . . . .102E1004S U . . .85, 98E2004S F . . .84, 99E2104S F-P .84, 101E3004S U-P 85, 100
C0973 FB . . . . . .42C1124 U . . . . . .102C4064 U . . . . . . .11C4103 U . . . . . .173C5086 U . . . . . .102
C0763 F . . . . . . .40C0974 FB . . . . . .42C1341 S . . . . . . .21C3311 F-P . . . .112C4066 U . . . . . . .11C4104 U . . . . . .173C4207 F . . . . . .177E1006S U . . .85, 98E2006S F . . .84, 99E2106S F-P .84, 101E3006S U-P 85, 100
C0975 FB . . . . . .42C4088 U . . . . . . .11C4105 U . . . . . .173
C0764 F . . . . . . .40C0976 FB . . . . . .42C1130 U . . . . . .102C4065 U . . . . . . .11C4080 U . . . . . .102C4106 U . . . . . .173C4208 F . . . . . .177C5096 U . . . . . .102E1008S U . . .85, 98E2008S F . . .84, 99E2108S F-P .84, 101E3008S U-P 85, 100
C0977 FB . . . . . .42C4070 U . . . . . . .11C4107 U . . . . . .173
C0765 F . . . . . . .40C0978 FB . . . . . .42C4071 U . . . . . . .11C4108 U . . . . . .173E1010S U . . . . . .98E2010S F . . .84, 99
C4067 U . . . . . . .11C4109 U . . . . . .173E1012S U . . . . . .98E2012S F . . .84, 99
C0782 F . . . . . . .40C1119 U . . . . . .102C1305 B,R . . . . .27C1331 F . . . . . .143C1343 F . . . . . .143C1644 B . . . . . . .25C2555 F . . . . . . .17C2683 B . . . . . . .23C3322 F-P . . . .112C3604 U,R . . . . .16C4119 U . . . . . .174C4161 F . . . . . .176C4196 F . . . . . .177C5078 U . . . . . .102C6353 U . . . . . . .12E1024S U . . . . . .98E2024S F . . . . . .99E2124S F-P . . . .101E3024S U-P . . .100
C1126 U . . . . . .102C1308 B,R . . . . .27C1645 B . . . . . . .25C3605 U,R . . . . .16C4120 U . . . . . .174C6355 U . . . . . . .12
C0783 F . . . . . . .40C1310 B,R . . . . .27C1646 B . . . . . . .25C3606 U,R . . . . .16
C1312 B,R . . . . .27C3607 U,R . . . . .16C4121 U . . . . . .174C6356 U . . . . . . .12
C0784 F . . . . . . .40C1313 B,R . . . . .27C1648 FB . . . . . .26C3608 U,R . . . . .16C4090 U . . . . . .102
C4122 U . . . . . .174C6357 U . . . . . . .12
C2511 F . . . . . .146C0785 F . . . . . . .40C3610 U,R . . . . .16C4123 U . . . . . .174
C6360 U . . . . . . .12
C0485 U . . . .85, 93C0494 F . . . .85, 94C3061 F-P . . . .111C3111 U-P . . . .109C3170 F-P . . .85, 96C3201 U-P . . . . .91C3242 U-P . .85, 95C3261 F-P . . . . .92E1504S U . . . . . .87E2504S F . . .85, 88E3504S U-P .85, 89E3604S F-P . .85, 90
C0444 U . . . . . . .15C1123 U . . . . . .102C1204 B,C . . . . .28C2404 U . . . . . . .12C2543 F . . . . . . .18C2688 B . . . . . . .23C3063 F-P . . . .111C3103 U-P . . . . .10C3113 U . . . . . .109C3163 F-P . . . .112C4127 U . . . . . .174C4204 F . . . . . .177C5084 U . . . . . .102E1034S U . . .85, 98E2034S F . . .84, 99E2204S F-P .84, 101E3034S U-P .85, 100
C3117 U-P . . . .109
C2420 U . . . . . . .12C4128 U . . . . . .174
C3118 U-P . . . .109E1506S U . . . . . .87E2506S F . . . . . .88E3506S U-P . . . .89E3606S F-P . . . .90C1206 B,C . . . . .28C3065 F-P . . . .111C3121 U-P . . . .109C3166 F-P . . . .112C3192 U-P . . . .110C4205 F . . . . . .177C4206 U . . . . . .174E1036S U . . . . . .98E2036 F . . . .84, 99E2206S F-P .84, 101E3036S U-P . . .100
C2421 U . . . . . . .12C4129 U . . . . . .174
C3119 U-P . . . .109E1508S U . . . . . .87E2508S F . . . . . .88C1208 B,C . . . . .28C3122 U-P . . . .109C3180 F-P . . . .112C3191 U-P . . . .110E1038S U . . . . . .98E2038S F . . .84, 99E2208S F-P .84, 101E3038S U-P . . .100
C2422 U . . . . . . .12C4130 U . . . . . .174
C1210 B,C . . . . .28C3178 U-P . . . .110C3181 F-P . . . .112E1040S U . . . . . .98E2040S F . . . . . .99
C1212 B,C . . . . .28C2412 U . . . . . . .12C3179 U-P . . . .110C3182 F-P . . . .112C4131 U . . . . . .174E1041S U . . . . . .98E2041S F . . . . . .99
C0486 U . . . . . . .93C3171 F-P . . . . .96C3211 U-P . . . . .91C3243 U-P . . . . .95C3271 F-P . . . . .92E1514S U . . . . . .87E2524S F . . . . . .88E3514S U-P . . . .89E3614S F-P . . . .90
C1604 B,C . . . . .28C1705 U . . .85, 157C2425 U . . . . . . .13C3195 U-P . . . .110C3341 F-P . . . .112C4137 U . . . . . .175E1044S U . . .85, 98E2044S F . . . . . .99E2244S F-P . . . .101E3044S U-P .85, 100
C2434 U . . . . . . .13C4138 U . . . . . .175
C1606 B,C . . . . .28
C2426 U . . . . . . .13C4139 U . . . . . .175
C1608 B,C . . . . .28C2443 U . . . . . . .13C4140 U . . . . . .175
C2435 U . . . . . . .13C4141 U . . . . . .175
C2427 U . . . . . . .13C4142 U . . . . . .175
C0496 F . . . . . . .94C3173 F-P . . . . .96C3223 U-P . . . . .91C3245 U-P . . . . .95C3284 F-P . . . . .92E1524S U . . .85, 87E2534S F . . .85, 88E3524S U-P .85, 89E3624S F-P . .85, 90
C1614 B,C . . . . .28C1703 U . . . . . .157C2430 U . . . . . . .13C4147 U . . . . . .175E1054S U . . .85, 98E2054S F . . . . . .99E2254S F-P . . . .101E3054S U-P .85, 100
C2437 U . . . . . . .13C4148 U . . . . . .175
C2431 U . . . . . . .13C4149 U . . . . . .175
C0497 F . . . . . . .94C3175 F-P . . . . .96C3225 U-P . . . . .91C3247 U-P . . . . .95C3283 F-P . . . . .92E1534S U . . . . . .87E2544S F . . . . . .88E3534S U-P . . . .89E3634S F-P . . . .90
C1701 U . . . . . .157C2440 U . . . . . . .13C4151 U . . . . . .175E1064S U . . .85, 98E2064S F . . . . . .99E2264S F-P . . . .101E3064S U-P .97, 100
218
Technical Information Electronics
B - BRAID SHIELD IFB - INDIVIDUAL FLEXFOIL® + FLEXFOIL® /BRAID UJ - UN-JACKETEDC - CAROLPRENE® P - PLENUMF - FLEXFOIL® SHIELD R - RUBBERFB - FLEXFOIL® /BRAID SHIELD S - SPIRAL SHIELDI - INDIVIDUAL FLEXFOIL® SHIELD U - NO SHIELD
NO.COND.
STRANDTYPE
AWG 28P/N SHIELD PAGE
AWG 24P/N SHIELD PAGE
AWG 22P/N SHIELD PAGE
AWG 20P/N SHIELD PAGE
AWG 19P/N SHIELD PAGE
AWG 18P/N SHIELD PAGE
AWG 16P/N SHIELD PAGE
AWG 14P/N SHIELD PAGE
AWG 12P/N SHIELD PAGE
15
18
19
20
25
30
40
50
SOLIDSTRANDED
SOLIDSTRANDED
SOLIDSTRANDED
SOLIDSTRANDED
SOLIDSTRANDED
SOLIDSTRANDED
SOLIDSTRANDED
SOLIDSTRANDED
C0538 FB . . . . . .43C0947 FB . . . . . .41C6507 B . . . . . . .24
C6508 B . . . . . . .24
C0539 FB . . . . . .43C0948 FB . . . . . .41
C0688 FB . . . . . .43C0746 F . . . . . . .39C0959 FB . . . . . .41C2473 U . . . . . . .10C4225 F . . . . . .180
C0747 F . . . . . . .39C0960 FB . . . . . .41C4226 F . . . . . .180
C0748 F . . . . . . .39C0961 FB . . . . . .41C4227 F . . . . . .180
C0749 F . . . . . . .39C4228 F . . . . . .180
C0750 F . . . . . . .39C4229 F . . . . . .180
C0751 F . . . . . . .39C4230 F . . . . . .180
C0766 F . . . . . . .40C0979 FB . . . . . .42C4073 U . . . . . . .11C4110 U . . . . . .173
C4111 U . . . . . .173
C0767 F . . . . . . .40C0980 FB . . . . . .42C4075 U . . . . . . .11C4112 U . . . . . .173
C0768 F . . . . . . .40C0981 FB . . . . . .42C4076 U . . . . . . .11C4113 U . . . . . .173
C4077 U . . . . . . .11C4114 U . . . . . .173
C4078 U . . . . . . .11C4115 U . . . . . .173
C4079 U . . . . . . .11C4116 U . . . . . .173
C6358 U . . . . . . .12C0786 F . . . . . . .40C4124 U . . . . . .174
C0787 F . . . . . . .40
C2423 U . . . . . . .12C4132 U . . . . . .174
C2424 U . . . . . . .12C4133 U . . . . . .174
C2433 U . . . . . . .12C4134 U . . . . . .174
C2428 U . . . . . . .13C4143 U . . . . . .175
C2429 U . . . . . . .13C4144 U . . . . . .175
C2436 U . . . . . . .13C4145 U . . . . . .175
Multi-Conductor Cable Product Finder
219
Electronics Technical Information
Multi-Paired Cable Product Finder
NO.PAIRS
STRANDTYPE
AWG 28P/N SHIELD PAGE
AWG 24P/N SHIELD PAGE
AWG 22P/N SHIELD PAGE
AWG 20P/N SHIELD PAGE
AWG 18P/N SHIELD PAGE
1
2
3
4
4.5
5
6
SOLID
STRANDED
SOLID
STRANDED
SOLID
STRANDED
SOLID
STRANDED
SOLID
STRANDED
SOLID
STRANDED
SOLID
STRANDED
C0804 FB . . . . . . . . . . . . . . . . . . . . . . .48
C0805 FB . . . . . . . . . . . . . . . . . . . . . . .48
C0806 FB . . . . . . . . . . . . . . . . . . . . . . .48
C0807 FB . . . . . . . . . . . . . . . . . . . . . . .48
C0600 F . . . . . . . . . . . . . . . . . . . . . . . .44C0841 FB . . . . . . . . . . . . . . . . . . . . . . .47C4841 FB . . . . . . . . . . . . . . . . . . . . . . .47C4170 F . . . . . . . . . . . . . . . . . . . . . . .178C4209 F . . . . . . . . . . . . . . . . . . . . . . .178
C0515 FB . . . . . . . . . . . . . . . . . . . . . . .50C0601 F . . . . . . . . . . . . . . . . . . . . . . . .44C0620 FB . . . . . . . . . . . . . . . . . . . . . . .46C0829 FB . . . . . . . . . . . . . . . . . . . . . . .49C0842 FB . . . . . . . . . . . . . . . . . . . . . . .47C0890 F . . . . . . . . . . . . . . . . . . . . . . . .45C0910 IF . . . . . . . . . . . . . . . . . . . . . . . .54C0924 IFB . . . . . . . . . . . . . . . . . . . . . . .55C3028 F-P . . . . . . . . . . . . . . . . . . . . . .116C3150 F-P . . . . . . . . . . . . . . . . . . . . . .113C3214 F-P . . . . . . . . . . . . . . . . . . . . . .115C4171 F . . . . . . . . . . . . . . . . . . . . . . .178C4842 FB . . . . . . . . . . . . . . . . . . . . . . .47
C0516 FB . . . . . . . . . . . . . . . . . . . . . . .50C0602 F . . . . . . . . . . . . . . . . . . . . . . . .44C0621 FB . . . . . . . . . . . . . . . . . . . . . . .46C0830 FB . . . . . . . . . . . . . . . . . . . . . . .49C0843 FB . . . . . . . . . . . . . . . . . . . . . . .47C0901 F . . . . . . . . . . . . . . . . . . . . . . . .45C0911 IF . . . . . . . . . . . . . . . . . . . . . . . .54C0925 IFB . . . . . . . . . . . . . . . . . . . . . . .55C3029 F-P . . . . . . . . . . . . . . . . . . . . . .116C3153 F-P . . . . . . . . . . . . . . . . . . . . . .113C3215 F-P . . . . . . . . . . . . . . . . . . . . . .115C4172 F . . . . . . . . . . . . . . . . . . . . . . .178C4843 FB . . . . . . . . . . . . . . . . . . . . . . .47C6065 IF . . . . . . . . . . . . . . . . . . . . . . . .51
C0517 FB . . . . . . . . . . . . . . . . . . . . . . .50C0603 F . . . . . . . . . . . . . . . . . . . . . . . .44C0831 FB . . . . . . . . . . . . . . . . . . . . . . .49C0844 FB . . . . . . . . . . . . . . . . . . . . . . .47C0893 F . . . . . . . . . . . . . . . . . . . . . . . .45C0912 IF . . . . . . . . . . . . . . . . . . . . . . . .54C0926 IFB . . . . . . . . . . . . . . . . . . . . . . .55C3030 F-P . . . . . . . . . . . . . . . . . . . . . .116C3151 F-P . . . . . . . . . . . . . . . . . . . . . .113C3216 F-P . . . . . . . . . . . . . . . . . . . . . .115C4173 F . . . . . . . . . . . . . . . . . . . . . . .178C4844 FB . . . . . . . . . . . . . . . . . . . . . . .47
C3217 F-P . . . . . . . . . . . . . . . . . . . . . .115
C0518 FB . . . . . . . . . . . . . . . . . . . . . . .50C0604 F . . . . . . . . . . . . . . . . . . . . . . . .44C0623 FB . . . . . . . . . . . . . . . . . . . . . . .46C0832 FB . . . . . . . . . . . . . . . . . . . . . . .49C4174 F . . . . . . . . . . . . . . . . . . . . . . .178
C0519 FB . . . . . . . . . . . . . . . . . . . . . . . . . .50C0605 F . . . . . . . . . . . . . . . . . . . . . . . . . . .44C0624 FB . . . . . . . . . . . . . . . . . . . . . . . . . .46C0839 FB . . . . . . . . . . . . . . . . . . . . . . . . . .49C0899 F . . . . . . . . . . . . . . . . . . . . . . . . . . .45C0913 IF . . . . . . . . . . . . . . . . . . . . . . . . . . .54C3031 F-P . . . . . . . . . . . . . . . . . . . . . . . . .116C3165 F-P . . . . . . . . . . . . . . . . . . . . . . . . .113C3218 F-P . . . . . . . . . . . . . . . . . . . . . . . . .115C4175 F . . . . . . . . . . . . . . . . . . . . . . . . . .178C6066 IF . . . . . . . . . . . . . . . . . . . . . . . . . . .51
C4008 U . . . . . . . . . . . . . . . . . . . . . .9, 30
C3204 F-P . . . . . . . . . . . . . . . . . . . . .113C0720 F . . . . . . . . . . . . . . . . . . . . . . . .44C4183 F . . . . . . . . . . . . . . . . . . . . . . .179C4203 IF . . . . . . . . . . . . . . . . . . . . . . .181
C1670 F . . . . . . . . . . . . . . . . . . . . . . . .32C4010 U . . . . . . . . . . . . . . . . . . . . . . . .30
C0550 F . . . . . . . . . . . . . . . . . . . . . . . .34C0570 IF . . . . . . . . . . . . . . . . . . . . . . . .37C0650 FB . . . . . . . . . . . . . . . . . . . . . . .46C0721 F . . . . . . . . . . . . . . . . . . . . . . . .44C1338 B . . . . . . . . . . . . . . . . . . . . . . .144C1350 IF . . . . . . . . . . . . . . . . . . . . . . . .35C1352 IF . . . . . . . . . . . . . . . . . . . . . . . .36C1353 IF . . . . . . . . . . . . . . . . . . . . . . . .36C3156 IF-P . . . . . . . . . . . . . . . . . . . . .117C3205 F-P . . . . . . . . . . . . . . . . . . . . . .113C3352 F-P . . . . . . . . . . . . . . . . . . . . . .114C4184 F . . . . . . . . . . . . . . . . . . . . . . .179C6010 U . . . . . . . . . . . . . . . . . . . . . . . .30
C6035 IF . . . . . . . . . . . . . . . . . . . . . . . .53
C0551 F . . . . . . . . . . . . . . . . . . . . . . . .34C0571 IF . . . . . . . . . . . . . . . . . . . . . . . .37C0651 FB . . . . . . . . . . . . . . . . . . . . . . .46C0722 F . . . . . . . . . . . . . . . . . . . . . . . .44C3157 IF-P . . . . . . . . . . . . . . . . . . . . .117C3206 F-P . . . . . . . . . . . . . . . . . . . . . .113C3353 F-P . . . . . . . . . . . . . . . . . . . . . .114C4185 F . . . . . . . . . . . . . . . . . . . . . . .179C6014 U . . . . . . . . . . . . . . . . . . . . . . . .30C6040 IF . . . . . . . . . . . . . . . . . . . . . . . .51
C1676 F . . . . . . . . . . . . . . . . . . . . . . . .32C4015 U . . . . . . . . . . . . . . . . . . . . . . . .30
C0552 F . . . . . . . . . . . . . . . . . . . . . . . .34C0572 IF . . . . . . . . . . . . . . . . . . . . . . . .37C0652 FB . . . . . . . . . . . . . . . . . . . . . . .46C0723 F . . . . . . . . . . . . . . . . . . . . . . . .44C3207 F-P . . . . . . . . . . . . . . . . . . . . . .113C3354 F-P . . . . . . . . . . . . . . . . . . . . . .114C4186 F . . . . . . . . . . . . . . . . . . . . . . .179
C0653 FB . . . . . . . . . . . . . . . . . . . . . . .46C0724 F . . . . . . . . . . . . . . . . . . . . . . . .44C4187 F . . . . . . . . . . . . . . . . . . . . . . .179
C1671 F . . . . . . . . . . . . . . . . . . . . . . . .32C6036 IF . . . . . . . . . . . . . . . . . . . . . . . .53
C0553 F . . . . . . . . . . . . . . . . . . . . . . . .34C0573 IF . . . . . . . . . . . . . . . . . . . . . . . .37C0654 FB . . . . . . . . . . . . . . . . . . . . . . .46C0725 F . . . . . . . . . . . . . . . . . . . . . . . .44C3208 F-P . . . . . . . . . . . . . . . . . . . . . .113C3356 F-P . . . . . . . . . . . . . . . . . . . . . .114C4188 F . . . . . . . . . . . . . . . . . . . . . . .179C6017 U . . . . . . . . . . . . . . . . . . . . . . . .30C6041 IF . . . . . . . . . . . . . . . . . . . . . . . .51
C6052 IF . . . . . . . . . . . . . . . . . . . . . . . .51C6061 IF . . . . . . . . . . . . . . . . . . . . . . .147
C1368 IF . . . . . . . . . . . . . . . . . . . . . . . .52
C6053 IF . . . . . . . . . . . . . . . . . . . . . . . .51C6062 IF . . . . . . . . . . . . . . . . . . . . . . .147
C6101 U . . . . . . . . . . . . . . . . . . . . . . . .31
C0560 F . . . . . . . . . . . . . . . . . . . . . . . .34C0584 IF . . . . . . . . . . . . . . . . . . . . . . . .37C3362 F-P . . . . . . . . . . . . . . . . . . . . . .114C6118 U . . . . . . . . . . . . . . . . . . . . . . . .31
C0561 F . . . . . . . . . . . . . . . . . . . . . . . .34C0585 IF . . . . . . . . . . . . . . . . . . . . . . . .37C6047 IF . . . . . . . . . . . . . . . . . . . . . . . .51C6103 U . . . . . . . . . . . . . . . . . . . . . . . .31
C0562 F . . . . . . . . . . . . . . . . . . . . . . . .34C0586 IF . . . . . . . . . . . . . . . . . . . . . . . .37C3364 F-P . . . . . . . . . . . . . . . . . . . . . .114C6119 U . . . . . . . . . . . . . . . . . . . . . . . .31
C6120 U . . . . . . . . . . . . . . . . . . . . . . . .31
C0563 F . . . . . . . . . . . . . . . . . . . . . . . .34C0587 IF . . . . . . . . . . . . . . . . . . . . . . . .37C6048 IF . . . . . . . . . . . . . . . . . . . . . . . .51C6106 U . . . . . . . . . . . . . . . . . . . . . . . .31
B - BRAID SHIELD IFB - INDIVIDUAL FLEXFOIL® + FLEXFOIL® /BRAID UJ - UN-JACKETEDC - CAROLPRENE® P - PLENUMF - FLEXFOIL® SHIELD R - RUBBERFB - FLEXFOIL® /BRAID SHIELD S - SPIRAL SHIELDI - INDIVIDUAL FLEXFOIL® SHIELD U - NO SHIELD
220
Technical Information Electronics
Multi-Paired Cable Product Finder
NO.PAIRS
STRANDTYPE
AWG 28P/N SHIELD PAGE
AWG 24P/N SHIELD PAGE
AWG 22P/N SHIELD PAGE
AWG 20P/N SHIELD PAGE
AWG 18P/N SHIELD PAGE
7
8
9
10
11
12
12.5
15
17
18
19
25
27
51
SOLID
STRANDED
SOLID
STRANDED
SOLID
STRANDED
SOLID
STRANDED
SOLID
STRANDED
SOLID
STRANDED
SOLID
STRANDED
SOLID
STRANDED
SOLID
STRANDED
SOLID
STRANDED
SOLID
STRANDED
SOLID
STRANDED
SOLID
STRANDED
SOLID
STRANDED
C0808 FB . . . . . . . . . . . . . . . . . . . . . . .48
C0810 FB . . . . . . . . . . . . . . . . . . . . . . .48
C0812 FB . . . . . . . . . . . . . . . . . . . . . . .48
C0520 FB . . . . . . . . . . . . . . . . . . . . . . .50C0606 F . . . . . . . . . . . . . . . . . . . . . . . .44C0625 FB . . . . . . . . . . . . . . . . . . . . . . .46C0833 FB . . . . . . . . . . . . . . . . . . . . . . .49C4176 F . . . . . . . . . . . . . . . . . . . . . . .178
C0521 FB . . . . . . . . . . . . . . . . . . . . . . .50C0607 F . . . . . . . . . . . . . . . . . . . . . . . .44C0626 FB . . . . . . . . . . . . . . . . . . . . . . .46C4177 F . . . . . . . . . . . . . . . . . . . . . . .178
C0608 F . . . . . . . . . . . . . . . . . . . . . . . .44C0914 IF . . . . . . . . . . . . . . . . . . . . . . . .54C4178 F . . . . . . . . . . . . . . . . . . . . . . .178C6067 IF . . . . . . . . . . . . . . . . . . . . . . . .51
C0522 FB . . . . . . . . . . . . . . . . . . . . . . .50C0609 F . . . . . . . . . . . . . . . . . . . . . . . .44C0628 FB . . . . . . . . . . . . . . . . . . . . . . .46C0835 FB . . . . . . . . . . . . . . . . . . . . . . .49C4179 F . . . . . . . . . . . . . . . . . . . . . . .178
C0915 IF . . . . . . . . . . . . . . . . . . . . . . . .54
C0836 FB . . . . . . . . . . . . . . . . . . . . . . .49C0916 IF . . . . . . . . . . . . . . . . . . . . . . . .54
C0523 FB . . . . . . . . . . . . . . . . . . . . . . .50C0630 FB . . . . . . . . . . . . . . . . . . . . . . .46C0897 F . . . . . . . . . . . . . . . . . . . . . . . .45C3152 F-P . . . . . . . . . . . . . . . . . . . . . .113
C0524 FB . . . . . . . . . . . . . . . . . . . . . . .50C0610 F . . . . . . . . . . . . . . . . . . . . . . . .44C0917 IF . . . . . . . . . . . . . . . . . . . . . . . .54C4180 F . . . . . . . . . . . . . . . . . . . . . . .178
C0525 FB . . . . . . . . . . . . . . . . . . . . . . .50
C0611 F . . . . . . . . . . . . . . . . . . . . . . . .44C4181 F . . . . . . . . . . . . . . . . . . . . . . .178
C0526 FB . . . . . . . . . . . . . . . . . . . . . . .50C0612 F . . . . . . . . . . . . . . . . . . . . . . . .44C4182 F . . . . . . . . . . . . . . . . . . . . . . .178
C0655 FB . . . . . . . . . . . . . . . . . . . . . . .46
C0656 FB . . . . . . . . . . . . . . . . . . . . . . .46
C1672 F . . . . . . . . . . . . . . . . . . . . . . . .32
C0554 F . . . . . . . . . . . . . . . . . . . . . . . .34C0574 IF . . . . . . . . . . . . . . . . . . . . . . . .37C0726 F . . . . . . . . . . . . . . . . . . . . . . . .44C4189 F . . . . . . . . . . . . . . . . . . . . . . .179C6042 IF . . . . . . . . . . . . . . . . . . . . . . . .51
C0658 FB . . . . . . . . . . . . . . . . . . . . . . .47
C6043 IF . . . . . . . . . . . . . . . . . . . . . . . .51
C6059 IF . . . . . . . . . . . . . . . . . . . . . . . .51
C0660 FB . . . . . . . . . . . . . . . . . . . . . . .46
C1673 F . . . . . . . . . . . . . . . . . . . . . . . .32
C0728 F . . . . . . . . . . . . . . . . . . . . . . . .44C4190 F . . . . . . . . . . . . . . . . . . . . . . .179C6044 IF . . . . . . . . . . . . . . . . . . . . . . . .51
C6060 IF . . . . . . . . . . . . . . . . . . . . . . . .51
C6045 IF . . . . . . . . . . . . . . . . . . . . . . . .51
C6046 IF . . . . . . . . . . . . . . . . . . . . . . . .51
C6451 F . . . . . . . . . . . . . . . . . . . . . . . .33
C6054 IF . . . . . . . . . . . . . . . . . . . . . . . .51
C6056 IF . . . . . . . . . . . . . . . . . . . . . . . .51
C6058 IF . . . . . . . . . . . . . . . . . . . . . . . .51
C6121 U . . . . . . . . . . . . . . . . . . . . . . . .31
C0564 F . . . . . . . . . . . . . . . . . . . . . . . .34C0588 IF . . . . . . . . . . . . . . . . . . . . . . . .37C6049 IF . . . . . . . . . . . . . . . . . . . . . . . .51C6109 U . . . . . . . . . . . . . . . . . . . . . . . .31
C6050 IF . . . . . . . . . . . . . . . . . . . . . . . .51
C6051 IF . . . . . . . . . . . . . . . . . . . . . . . .51
B - BRAID SHIELD IFB - INDIVIDUAL FLEXFOIL® + FLEXFOIL® /BRAID UJ - UN-JACKETEDC - CAROLPRENE® P - PLENUMF - FLEXFOIL® SHIELD R - RUBBERFB - FLEXFOIL® /BRAID SHIELD S - SPIRAL SHIELDI - INDIVIDUAL FLEXFOIL® SHIELD U - NO SHIELD
221
Electronics Technical Information
Reprinted with permission from NFPA 70-2002 National Electrical Code ®, copyright © 2005, National FireProtection Association, Quincy, MA 02269. This reprinted material is not the complete and official position ofthe NFPA on the referenced subject, which is represented only by the standard in its entirety.National Electrical Code® and the NEC© are registered trademarks of the NFPA.
NEC Substitution Chart
(Highest) Plenum Cables
Riser Cables Multiple FloorsGeneral-Purpose Cables(Lowest) ResidentialCables Restricted Use
FIRE RESISTANCE LEVEL TEST REQUIREMENTNEC ARTICLE
NFPA 262 (Steiner tunnel)CSA-CMP (Steiner tunnel)
UL-1666 (Vertical Shaft)CSA-CMG (Vertical Tray)
UL-1581 (Vertical Tray)
CSA-CMG (Vertical Tray)UL-1581 VW-1
CMP
CMG
CMX
800
Communication wire and cable forpremise installations in accordancewith Article 800, and other applicableparts of the National Electrical Code(NEC), latest issue. Communicationwire and cables for Canada are inaccordance with the harmonizedCanadian Standard AssociationC22.2 No. 214, UnderwritersLaboratories UL 444, latest issue.
Notes: 1. Cables with a higher fire resistance level may be substituted for those with a lower fire resistance level.2. Non-fire rated outside plant telephone cables may not run outside of a rigid metal conduit more than 50 feet from
the point of entrance into a building.3. Cables rated CMG or CM may be used in runs penetrating one floor. (NEC 800-53)
Article 800Table 800-53. Cable Uses and Permitted Substitutions
CMP
CMR
CMG, CM
CMX
Communicationsplenum cable
Communicationsriser cable
Communicationsgeneral purpose cable
Communicationscable, limited use
800-53(a)
800-53(b)
800-53(d)
800-53(d)
CMP
CMP, CMR, MPG, MP
CMP, CMR, CMG, CM
CABLE TYPE USE REFERENCES PERMITTED SUBSTITUTIONS
Article 725Table 725-61. Cable Uses and Permitted Substitutions
CL3P
CL2P
CL3R
CL2R
PLTC
CL3
CL2
CL3X
CL2X
Class 3 plenum cable
Class 2 plenum cable
Class 3 riser cable
Class 2 riser cable
Power-limited tray cable
Class 3 cable
Class 2 cable
Class 3 cable, limited use
Class 2 cable, limited use
725-61(a)
725-61(a)
725-61(b)
725-61(b)
725-61(c)and (d)
725-61(b), (e)and (f)
725-61(b), (c)and (f)
725-61(b)and (e)
725-61(b)and (e)
CMP
CMP, CL3P
CMP, CL3P, CMR
CMP, CL3P, CL2P, CMR,CL3R
CMP, CL3P, CMR, CL3RCMG, CM, PLTC
CMP, CL3P, CL2P, CMR,CL3R, CL2R, CMG, CM,PLTC, CL3
CMP, CL3P, CMR, CL3R,CMG, CM, PLTC, CL3,CMX
CMP, CL3P, CL2P, CMR, CL3R,CL2R, CMG, CM, PLTC, CL3,CL2, CMX, CL3X
CABLE TYPE USE REFERENCES PERMITTED SUBSTITUTIONS
CMGCM
CMR
CMX
CMPPlenum
Riser
General Purpose
Dwellings
Type CM — Communications cables.
’ Cable A shall be permitted to be used inplace of Cable B
BA
Note: See Figure 800-53, Cable Substitution Hierarchy
Note: See Figure 725-61, Cable Substitution Hierarchy
Figure 800-53, Cable Substitution Hierarchy
Plenum
Riser
General Purpose
Dwellings
CMGCM
CMR
CMP
CL3R
CL3
CL3XCMX
CL3P
CL2R
CL2
CL2X
CL2P
PLTC
Type CM — Communications wires and cables.Type CL2 and CL3 — Class 2 and Class 3
remote-control, signaling andpower-limited cables
Type PLTC — Power-limited tray cable
’ Cable A shall be permitted to be used inplace of Cable B
BA
Figure 725-61, Cable Substitution Hierarchy
CL3PCL2P
CL3RCL2R
CL3
CL2CL3X
725
FPLP
FPLR
FPL
760
CATVP
CATVR
CATV
CATVX
820
222
Technical Information Electronics
Article 760Table 760-61. Cable Uses and Permitted Substitutions
FPLP
FPLR
FPL
Power-limited fire alarmplenum cable
Power-limited fire alarmriser cable
Power-limited fire alarmcable
760-61(a)
760-61(b)
760-61(c)
CMP
CMP, FPLP,CMR
CMP, FPLP,CMR, FPLR,CMG, CM
MPP
MPP, MPR
MPP, MPR,MPG, MP
CABLE TYPE USE REFERENCES
PERMITTED SUBSTITUTIONS
MULTICONDUCTOR COAXIAL
Article 820Table 820-53. Coaxial Cable Uses and Permitted Substitutions
CATVP
CATVR
CATV
CATVX
Coaxial plenum cable
Coaxial riser cable
Coaxial general purposecable
Coaxial cable, limited use
820-53(a)
820-53(b)
820-53(c)
820-53(c)
CMP
CATVP , CMP, CMR
CATVP, CMP, CATVR, CMR,CMG, CM
CATVP, CMP, CATVR, CMR,CATV, CMG, CM
CABLE TYPE USE REFERENCES PERMITTED SUBSTITUTIONS
NEC Substitution Chart
Plenum
Multiconductorcables
Riser
General Purpose CMGCM
CMR
CMP
FPLR
FPL
FPLP
Type CM — Communications wires and cablesType FPL — Power-limited fire alarm cables
’ Cable A shall be permitted to be used inplace of Cable B
No. 26 minimum
BA
Note: See Figure 760-61, Cable Substitution Hierarchy
Note: See Figure 820-53, Cable Substitution Hierarchy
Figure 760-61, Cable Substitution Hierarchy
Plenum
Riser
General Purpose
Dwellings
CMGCM
CMR
CMP
CMX
CATVR
CATV
CATVX
CATVP
Type CATV — Community antenna television cablesType CM — Communications cables
’ Coaxial Cable A shall be permitted to beused in place of Coaxial Cable B
BA
Figure 820-53, Cable Substitution Hierarchy
Reprinted with permission from NFPA 70-2002 National Electrical Code ®, copyright © 2005, National FireProtection Association, Quincy, MA 02269. This reprinted material is not the complete and official position ofthe NFPA on the referenced subject, which is represented only by the standard in its entirety.National Electrical Code® and the NEC© are registered trademarks of the NFPA.
223
Electronics Technical Information
Agency Symbols
SYMBOL DESCRIPTION SYMBOL DESCRIPTION
UL Listed Mark for the United States
UL Listed Mark for Canada
UL Listed Mark for Canada andthe United States
UL Recognized Component Mark forthe United States
IA/EIA 568A Cat. 5
TIA/EIA 568A Cat. 3
California State Fire Marshal
RoHS Compliant Directive2002/95/EC
CSA CMP
CSA CMG
CSA CMH
UL 910 Steiner Flame Test
UL Vertical Tray Flame Test
UL 1666 Riser Flame Test
IMSA
Put-Up Put-Up Code Packaging Code Packaging
03 3 ft Coax w/ Connector HD 70 Cord Hanked, coil w/cuff06 6 ft Coax w/ Connector HD 73 Cord Set, long length11 50 ft Spool 74 12' Clamshell w/ connectors12 100 ft Spool 75 25' Clamshell w/ connectors13 Clamshell 76 50' Clamshell w/ connectors15 250 ft Spool 77 100' Clamshell w/ connectors18 500 ft Spool 78 15,000 ft Reel20 900 ft Spool 79 8,000 ft Reel21 1000 ft Spool 80 Blister Pack w/ connectors24 2500 ft Spool 85 250 ft Coil25 500 ft Pull Pac 88 12' Sleeve w/o connector26 5000 ft Spool 89 25' Sleeve w/o connector30 1000 ft Pull Pac 90 50' Sleeve w/o connector32 150 ft Reel 91 75' Sleeve w/o connector33 100 ft Reel 92 100' Sleeve w/o connector34 200 ft Coil 93 Bulk Reel35 250 ft Reel 94 Display36 300 ft Reel 96 Wiring Devise, Skin Pack38 500 ft Reel 99 Factory Reel39 500 Meter = 1,640 ft XX Various Lengths40 Long Length Reel41 1000 ft Reel A1 250 ft Spool Pack42 1500 ft Reel A2 500 ft Spool Pack43 2000 ft Reel A3 1000 ft Spool Pack44 2500 ft Reel A4 2000 ft Spool Pack45 4000 ft Reel R5 250 ft Spool, Retail46 5000 ft Reel R8 500 ft Spool, Retail47 7500 ft Reel48 10,000 ft Reel49 1600 ft Reel50 1000 Meter (3280')51 4500 ft Reel52 3000 ft Reel53 25 ft Cuff54 12 ft Clamshell55 25 ft Clamshell56 50 ft Clamshell57 100 ft Clamshell58 12 ft Sleeve w/connectors59 25 ft Sleeve w/connectors60 Cord Hanked, coil w/cuff61 Cord Set Box62 Cord Set Bag63 Cord Set Sleeve64 50 ft Sleeve w/connectors65 100 ft Sleeve w/connectors66 50 ft Cuff67 100 ft Cuff68 3500 ft Reel69 Retail Spool Pac
224
Technical Information Electronics
Put-Ups and Color Codes
PUT-UP CODES
Put-Up Put-Up Code Packaging Code Packaging
00 Uninsulated 69 Maple01 Black 70 Walnut02 White 71 Wrought Iron03 Red 72 Copper04 Orange 73 White/Black/Red05 Yellow 74 White/Black/Orange06 Green 75 White/Black/Yellow07 Dark Blue 76 White/Black/Green08 Brown 77 White/Black/Blue09 Maroon 78 White/Black/Brown10 Gray 79 White/Black/Violet11 Antique Gold 80 White/Black/Gray12 Ivory 81 Black/Red/White13 Pink 82 Orange/Green/Black14 Light Green 86 Natural15 Clear Gold 88 Tan16 Light Blue 90 Clear17 Beige 91 Clear Brown18 Light Brown 92 Clear Blue19 Purple 93 Clear Red20 Clear Silver 96 Twisted Cond. No Jkt21 Light Purple 97 1 Stripe22 Neon Green 98 2 Stripes23 Mint Green 99 Assorted Colors24 Raspberry25 Gold31 White/Black33 White/Red34 White/Orange35 White/Yellow36 White/Green37 White/Blue38 White/Brown39 White/Violet40 White/Gray41 Red/Green42 Green/White43 Blue/Red44 Blue/White45 Orange/Red46 Orange/Black47 Yellow/White48 Yellow/Black49 Blue/White50 Blue/Black56 Black w/White Trace62 Silver Gray (Lt Gray)66 Light Green67 Lime Green68 Birch
JACKET COLOR CODES
225
Electronics Technical Information
Product Description Index
AAbbreviations and Acronyms . . . . . . . . . . . . . . . . . . . . . . . . .212-214Addressable Fire Alarm System Cable . . . . . . . . . . . . . . . . . . . .93-96Agency Symbols . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .223Analog Video Coaxial Cable . . . . . . . . . . . . . . . . . . .56, 61-62, 66-69Antenna Rotor Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .102Audio Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .95-107AWG Conductor Chart . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .196
BBroadcast Coaxial Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .57-71Burglar Alarm Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .103
CCable
Addressable Fire Alarm System . . . . . . . . . . . . . . . . . . . . . . .86-96Antenna Rotor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .102Audio . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .119-158Burglar Alarm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .103
CAD/CAM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .43, 54-55, 59-60CCTV (Closed Circuit Television) . . . . . . . . . . . . . . . . . . . . . . . .145Camera . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .120, 121, 128-129Carolprene® Jacketed . . . . . . . . . . . . . . . . . . . . . . . . . . . .28, 32-33Category 3, 5e, or 6 . . . . . . . . . . . . . . . . . . . . . . . . .84-85, 160-165 Coaxial . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .56-83Communication . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8-28, 29-37Computer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .38-55Computer Interconnect . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .34Computer/LAN - Coaxial Cable . . . . . . . . . . . . . . . . . . . . . . .57-60Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8-28, 29-37Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .76-79Datacom . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .84, 160-165Direct Burial - Audio and Communication . . . . . . . . . . . . . .146-147Direct Burial - Coaxial . . . . . . . . . . . . . . . . . . . . . . . .58, 61, 64, 69Fire Alarm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .86-96HVAC Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .95-107Intercom . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .103Lo-Cap® . . . . . . . . . . . . . . . . . . . . . . . . .43, 45, 47-50, 54-55, 116Low Capacitance . . . . . . . . . . . . . . . . . . .43, 45, 47-50, 54-55, 116Microphone . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .135-136Mid-Capacitance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .91-94Miniature Coaxial . . . . . . . . . . . . . . . . . . . . . . . . . . . . .71, 130-132Multi-Conductor . . . . . . . . . . . . .9-19, 22-25, 32-46, 51-53, 87-92,
98-101, 109-112 Multi-Paired . . . . . . . . . . . . . . . . . . . . . . .44-55, 113-117, 219-220Plenum . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .108-118Power-Limited Tray . . . . . . . . . . . . . . . . . . . . . . . . . .15, 20, 34, 37RS-232 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .30-31, 39-44RS-422 . . . . . . . . . . . . . . . . . . . . . . . . . . . . .48-49, 54-55, 115-116RS-423 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .50RS-485 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .47Rubber Jacketed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16, 27, 140Satellite Actuator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14Security . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .95-107Smoke Detector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 86-96Sound System . . . . . . . . . . . . . . . . . . . . . . . . . . . .98-101, 155-157Special Application . . . . . . . . . . . . . . . .142-148, 152-158, 174-181Telephone . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .103Twinaxial . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .73
CAD/CAM Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . .43, 54-55, 59-60Camera Cable . . . . . . . . . . . . . . . . . . . . . . . . .120-121, 128-129, 145Carolprene® Jacketed Cable . . . . . . . . . . . . . . . . . . . . . . . . . .28, 141
Category 3, 5e, or 6 Cable . . . . . . . . . . . . . . . . . . . . . . . .84, 160-165CATV Coaxial Cable . . . . . . . . . . . . . . . . . . . .57-58, 63-64, 66, 68, 71CCTV (Closed Circuit Television) . . . . . . . . . . . . . . . . . . . . .63, 66, 71Coaxial Cable
Aerial . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .56Analog Video . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .57-60Broadcast . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .57, 59-62, 65, 73Camera . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .120, 121, 128-129CATV . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .75, 81CCTV . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .57, 63, 66, 71Computer/LAN . . . . . . . . . . . . . . . . . . . . . . . . . . .58-59, 61, 66-69Design Equations - Braid Shield . . . . . . . . . . . . . . . . . . . . . . . .197Design Equations - Coaxial Cable . . . . . . . . . . . . . . . . . . . . . .198Digital Video . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .58-60, 67Direct Broadcast Satellite (DBS) . . . . . . . . . . . . . . . . . . . . . . . . .59Direct Burial . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .58, 61, 64, 69DVD (Digital Versatile Disc) . . . . . . . . . . . . . . . . . . . .62, 85, 73, 127FM Broadcast . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .57, 60-61Local Area Network (LAN) . . . . . . . . . . . . . . . . . . . . . . . . . . .76-79MATV (Master Antenna Television) . . . . .57-58, 61, 63-64, 66-69, 71Plenum . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .108-118Precision Video . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .72Product Finder Chart . . . . . . . . . . . . . . . . . . . . . . . . . . . . .225-227RF Transmission . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .60-71RG 6/U Type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .57-60RG 7/U Type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .61RG 8/U Type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .62RG 11/U Type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .63-64RG 58/U Type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .65RG 59/U Type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .66-69RG 62/U Type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .70RG 174/U Type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .71RG 213/U Type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .71Thinnet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .80Twinaxial . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .73
Communications CableMulti-Conductor, Braid Shield . . . . . . . . . . . . . . . . . . . . . . . . .22-25Multi-Conductor, Carolprene®, Braid Shield . . . . . . . . . . . . . . . . .28Multi-Conductor, Foil Shield . . . . . . . . . . . . . . . . . . . . . . . . . .17-19Multi-Conductor, Foil/Braid Shield . . . . . . . . . . . . . . . . . . . . . . . .26Multi-Conductor, Rubber, Braid Shield . . . . . . . . . . . . . . . . . . . . .27Multi-Conductor, Rubber, Unshielded . . . . . . . . . . . . . . . . . . . . .16Multi-Conductor, Spiral Shield . . . . . . . . . . . . . . . . . . . . . . . . . . .21Multi-Conductor, Unshielded . . . . . . . . . . . . . . . . . . . . . . . . . .9-14Multi-Paired, Foil Shield . . . . . . . . . . . . . . . . . . . . . . . . . . . . .32-33Multi-Paired, Individually Shielded . . . . . . . . . . . . . . . . . . . . .35-36Multi-Paired, Unshielded . . . . . . . . . . . . . . . . . . . . . . . . . . . .30-31Power-Limited Tray Cable, Foil Shield . . . . . . . . . . . . . . . . . . . . .34Power-Limited Tray Cable, Individually Shielded . . . . . . . . . . . . .37Power-Limited Tray Cable, Unshielded . . . . . . . . . . . . . . . . . . . .15
Computer CableInterconnect Cable . . . . . . . . . . . . . . . . . . . . . . . . . . .30-31, 34-35Multi-Conductor, Foil Shield . . . . . . . . . . . . . . . . . . . . . . . . . .39-40Multi-Conductor, Foil/Braid Shield . . . . . . . . . . . . . . . . . . . . .41-42Multi-Conductor, Lo-Cap®, Foil/Braid Shield . . . . . . . . . . . . . . . .43Multi-Paired, Foil Shield . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .44Multi-Paired, Foil/Braid Shield . . . . . . . . . . . . . . . . . . . . . . . . . . .46Multi-Paired, Individually Shielded . . . . . . . . . . . . . . . . . . . . .51-53Multi-Paired, Lo-Cap®, Foil Shield . . . . . . . . . . . . . . . . . . . . . . . .45Multi-Paired, Lo-Cap®, Foil/Braid Shield . . . . . . . . . . . . . . . . .47-50Multi-Paired, Lo-Cap®, Individually Shielded . . . . . . . . . . . . . . . .54
226
Technical Information Electronics
Product Description Index
Multi-Paired, Lo-Cap®, Individually Foil/Braid Shielded . . . . . . . .55Computer/LAN - Coaxial Cable . . . . . . . . . . . . . . .58-59, 62, 66-69
Conduit Capacity Chart . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .187Cord, Lamp . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .153Cross Reference Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .228-232
DData Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .76-79Datacom (Category) Cable . . . . . . . . . . . . . . . . . . . . . . . .84, 160-165Decimal Conversion Factors Chart . . . . . . . . . . . . . . . . . . . . . . . .184Design Equations - Balanced Pair . . . . . . . . . . . . . . . . . . . . . . . . .199Design Equations - Braid Shield . . . . . . . . . . . . . . . . . . . . . . . . . .197Design Equations - Coaxial Cable . . . . . . . . . . . . . . . . . . . . . . . . .198Digital Video (Coaxial Cable) . . . . . . . . . . . . . . . . . . . . . . . . .122-123Direct Broadcast Satellite (DBS) Coaxial Cable . . . . . . . . . . . . . . . .59Direct Burial - Audio and Communication Cable . . . . . . . . . . .146-147Direct Burial - Coaxial Cable . . . . . . . . . . . . . . . . . . . . .58, 61, 64, 69DVD (Digital Versatile Disc) Coaxial Cable . . . . . . .57, 68, 84, 155-157
EEngineering Prefixes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .200
FFire Alarm Cable
Mid-Capacitance, Unshielded, Non-Plenum . . . . . . . . . . . . . . . .93Mid-Capacitance, Shielded, Non-Plenum . . . . . . . . . . . . . . . . . .94Mid-Capacitance, Unshielded, Plenum . . . . . . . . . . . . . . . . . . . .95Mid-Capacitance, Shielded, Plenum . . . . . . . . . . . . . . . . . . . . . .96Multi-Conductor, Unshielded, Non-Plenum . . . . . . . . . . . . . . . . .87Multi-Conductor, Shielded, Non-Plenum . . . . . . . . . . . . . . . . . . .88Multi-Conductor, Unshielded, Plenum . . . . . . . . . . . . . . . . . . . . .89Multi-Conductor, Shielded, Plenum . . . . . . . . . . . . . . . . . . . . . . .90Multi-Conductor, Unshielded, Plenum, PVDF Jacketed . . . . . . . .91Multi-Conductor, Shielded, Plenum, PVDF Jacketed . . . . . . . . . .92
FM Broadcast Coaxial Cable . . . . . . . . . . . . . . . . . . . . . . . .57, 60-61
GGlossary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .201-211
HHook-Up Wire . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-7Hook-Up Wire Product Finder Chart . . . . . . . . . . . . . . . . . . . . . . .215HVAC Control Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .98-101
I
Insulation & Jacket Materials Property Chart . . . . . . . . . . . . . . . . .183Intercom Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .103Interconnect (Computer) Cable . . . . . . . . . . . . . . . . . . . . . . . . . .38-55
LLo-Cap® Cable . . . . . . . . . . . . . . . . . . . . . .43, 45, 47-50, 54-55, 116Low Capacitance Cable . . . . . . . . . . . . . . . .43, 45, 47-50, 54-55, 116Low Voltage Sprinkler Wire . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .104
MMATV Coaxial Cable . . . . . . . . . . . . . . . .75, 62-63, 66, 68-71, 72, 76Microphone Cable
Multi-Conductor, Braid Shield . . . . . . . . . . . . . . . . . . . . . . . . . .139Multi-Conductor, Carolprene®, Braid Shield . . . . . . . . . . . . . . . .141Multi-Conductor, Flexfoil Shield . . . . . . . . . . . . . . . . . . . . . . . . .138Multi-Conductor, Rubber, Braid Shield . . . . . . . . . . . . . . . . . . . .140Multi-Conductor, Spiral Shield . . . . . . . . . . . . . . . . . . . . . . . . . .137
Mid-Capacitance Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .93-96Miniature Coaxial Cable . . . . . . . . . . . . . . . . . . . . . . . . . .71, 130-132Multi-Conductor Cable . . . . . . . . . .9-19, 22-25, 32-46, 51-53, 87-92,
98-101, 109-112
Multi-Paired Cable . . . . . . . . . . . . . . . . . . . .44-55, 113-117, 219-220NNEC Substitution Chart . . . . . . . . . . . . . . . . . . . . . . . . . . . . .221-222
PPVC Test Lead Wire . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7Part Number Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .234-236Plenum Cable
Multi-Conductor, Foil Shield . . . . . . . . . . . . . . . . . . . . . . . .111-112Multi-Conductor, Unshielded . . . . . . . . . . . . . . . . . . . . . . .109-110Multi-Paired, Foil Shield . . . . . . . . . . . . . . . . . . . . . . . . . . .113-114Multi-Paired, Individually Foil Shielded . . . . . . . . . . . . . . . . . . . .117Multi-Paired, Lo-Cap®, Foil Shield . . . . . . . . . . . . . . . . . . . . . . .116Multi-Paired, Mid-Cap . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .115
Plenum Coaxial Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .109-118Point-to-Point Wire . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-5Power-Limited Tray Cable
Foil Shield . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20, 34Individually Shielded . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .37Unshielded . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15
Precision Video Coaxial Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . .72Product Finder Charts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .215-220
RRetail Packaged Wire Products . . . . . . . . . . . . . . . . . . . . . . . . . . .156RF Transmission Coaxial Cable . . . . . . . . . . . . . . . . . . . . . . . . .60-71RG 6/U Type Coaxial Cable . . . . . . . . . . . . . . . . . . . . .57-60, 122-123RG 7/U Type Coaxial Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .61RG 8/U Type Coaxial Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .62RG 11/U Type Coaxial Cable . . . . . . . . . . . . . . . . . . . . . . . . . . .63-64RG 58/U Type Coaxial Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .65RG 59/U Type Coaxial Cable . . . . . . . . . . . . . . . . . . . . . . . . . . .66-69RG 62/U Type Coaxial Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .70RG 174/U Type Coaxial Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . .71RG 213/U Type Coaxial Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . .71RS-232 . . . . . . . . . . . . . . . . . . . . . . .30-31, 39-44, 46, 48-50,113-116RS-422 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .48-49, 54-55, 115-116RS-423 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .43, 50Rubber Jacketed Cable
Multi-Conductor, Braid Shield . . . . . . . . . . . . . . . . . . . . . . . . .22-25Multi-Conductor, Unshielded . . . . . . . . . . . . . . . . . . . . . . . . . .9-14
Rubber Test Lead Wire . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
SSatellite Actuator Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14Security Cable
Multi-Conductor, Shielded, Plenum . . . . . . . . . . . . . . . . . . . . . .101Multi-Conductor, Shielded, Riser . . . . . . . . . . . . . . . . . . . . . . . . .99Multi-Conductor, Unshielded, Plenum . . . . . . . . . . . . . . . . . . . .100Multi-Conductor, Unshielded, Riser . . . . . . . . . . . . . . . . . . . . . .98
Smoke Detector Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .87-96Sound System Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .97-99Speaker Wire . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .152-158Special Application Cable
Audio . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .142-144Camera . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .120, 145CCTV (Closed Circuit Television) . . . . . . . . . . . . . . . .57, 63, 66, 71Direct Burial - Audio & Communication . . . . . . . . . . . . . . . .146-147Direct Burial - Traffic Loop Detector . . . . . . . . . . . . . . . . . . . . . . . .Instrumentation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .113-117
Sprinkler Wire . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .104
TTechnical Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .182-238Telephone (Station) Wire . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .103
227
Electronics Technical Information
Product Description Index
Temperature Conversion Chart . . . . . . . . . . . . . . . . . . . . . . . . . . .186Test Lead Wire . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7Thermostat Wire . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .105-107Thinnet (Coaxial Cable) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .80Tray Cable, Power-Limited . . . . . . . . . . . . . . . . . . . . . . . . . .15, 34, 37Twinaxial Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .73
UUnit Conversion Factors Chart . . . . . . . . . . . . . . . . . . . . . . . . . . . .185
WWire
Hook-Up . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-7Point-to-Point . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-5Speaker . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .152-158Telephone Station . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .103Test Lead . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
228
Technical Information Electronics
1032A C0454 201186A C5784 681189A C5785 58, 841190A C5804 581223A C5812 591426A C1142 66, 841513A C5776 571523A C5039 631524A C5041 641525A C5043 641530A C5776 571613A C5812 591617A C5044 631694A C5814 591833A C5857 611840A C5826 591841A C5822 591846A C5853 611847A C5856 615000FE E2062S 995000UE E1062S 85, 985002UE E1064S 85, 985020FL E2542S 885020UL E1532S 875100UE E1052S 85, 985102UE E1054S 85, 985120FL E2532S 85, 885120LL E2406S 875120UL E1522S 85, 875122FL E2534S 85, 885122UL E1524S 85, 875200FE E2042S 995200UE E1042S 85, 985201FE C2537 175202UE E1044S 85, 985220FL E2522S 885220LL E2404S 875220UL E1512S 875222FL E2524S 885222UL E1514S 875300FE E2032S 84, 995300UE E1032S 85, 985301FE E2033S 995301UE E1033S 985302FE E2034S 84, 995302UE E1034S 85, 985304FE E2036S 84, 995304UE E1036S 985306UE E1038S 985308UE E1040S 985309UE E1041S 985320FE E2030S 99
5320FL E2502S 85, 885320LL E2402S 875320UE E1030S 985320UL E1502S 85, 875321FL E2503S 885321UL E1503S 875322FL E2504S 85, 885322UL E1504S 85, 875324UL E1506S 875400FE E2022S 995401FE E2023S 995401UE E1023S 985402FE E2024S 995402UE E1024S 985500FE E2002S 94, 995500UE E1002S 95, 985501FE E2003S 995501UE E1003S 985502FE E2004S 94-995502UE E1004S 85, 985504FE E2006S 84, 995504UE E1006S 85, 985506FE E2008S 84, 995506UE E1008S 85, 985508UE E1010S 985509FE E2012S 84, 995509UE E1012S 985520FE E2000S 995520UE E1000S 985522UE E1001S 985522UL E1484S 876000UC C3129 1096020FL E3632S 906020UL E3532S 896100FE E2252S 1016100UE E3052S 85, 1006100UF C3128 1096102UE E3054S 85, 1006120UL E3522S 85, 896122FL E3624S 85, 896122UL E3524S 85, 896200FE C3169 1126200FE E2242S 1016200UE C3127 1096200UE E3042S 85, 1006201FE E2243S 1016201UE E3043S 1006202FE C3341 1126202FE E2244S 1016202UE E3044S 85, 1006220FL E3612S 906220UL E3512S 89
BELDEN GC/CAROLPART NO. PART NO. PAGE NUMBER
BELDEN GC/CAROLPART NO. PART NO. PAGE NUMBER
Belden-to-General Cable Carol® Brand Cross Reference Index
This cross reference guide should be used in conjunction with the product information in this catalog. It should beused for suggested alternative items which are functionally equal. Constructional differences are not indicated. GeneralCable is not responsible for variances due to competitor and industry constructional changes or agency updates.
229
Electronics Technical Information
6222FL E3614S 906222UL E3514S 896300FE E2202S 84, 1016300UE E3032S 85, 1006301FE E2203S 1016301UE C3120 1096301UE E3033S 1006302FE E2204S 84, 1006302UE C3113 1096302UE E3034S 85, 1006304FE E2206S 84, 1016304UE C3121 1096304UE E3036S 1006306UE C3122 1096306UE E3038S 1006320FE E2200S 1016320FL E3602S 85, 906320UE E3030S 1006321FL E3603S 906321UL E3503S 896322FL E3604S 85, 906322UL E3504S 85, 976324UL E3506S 896400FE E2122S 1016400UE E3022S 1006401FE E2123S 1016401UE E3023S 1006402FE E2124S 1016402UE E3024S 1006500FE E2102S 84, 1016500UE E3002S 85, 1006501FE E2103S 1016501UE E3003S 1006502FE E2104S 84, 1016502UE E3004S 85, 1006504FE E2106S 84, 1016504UE E3006S 85, 1006506FE E2108S 84, 1016506UE E3008S 85, 1006520FE E2100S 1016520UE E3000S 1006522UE E3001S 100
8102 C0515 508103 C0516 508104 C0517 508105 C0518 508106 C0519 508107 C0520 508108 C0521 508112 C0523 508115 C0524 508118 C0525 50
BELDEN GC/CAROLPART NO. PART NO. PAGE NUMBER
8125 C0526 508162 C0924 558163 C0925 558164 C0926 558205 E1022S 988212 C1102 668213 C5025 638214 C1198 628215 C5810 588216 C1156 718218 C1158 698219 C1188 658221 C1135 6682241 C3500 69, 84, 11882248 C3523 60, 84, 11882262 C3520 70, 1188228 C5760 578233 C5027 648237 C1154 628240 C1166 658241 C1106 668241 C1107 6682442 E3002S 85, 1008259 C1178 658261 C1160 638262 C1155 658263 C1106 668267 C1176 71
8281B C5816 6782907 C3579 1188302 C0650 468303 C0651 468304 C0652 468305 C0653 468306 C0654 468307 C0655 468308 C0656 468310 C0658 468312 C0660 468332 C0620 468333 C0621 468335 C0623 468336 C0624 468337 C0625 468340 C0628 468342 C0630 468412 C1302 27, 1408418 C1313 278422 C1322 1398423 C1304 278424 C1305 278425 C1308 27
BELDEN GC/CAROLPART NO. PART NO. PAGE NUMBER
This cross reference guide should be used in conjunction with the product information in this catalog. It should beused for suggested alternative items which are functionally equal. Constructional differences are not indicated. GeneralCable is not responsible for variances due to competitor and industry constructional changes or agency updates.
Belden-to-General Cable Carol® Brand Cross Reference Index
230
Technical Information Electronics
8426 C1310 278427 C1312 278428 C1202 28, 1418437 C2676 228441 C2677 228442 C6348 118443 C4062 118444 C4063 118444 E1004S 85, 988445 C4064 118446 C4081 148447 C4082 148448 C4083 148449 C4084 148450 C2515 178451 C2516 178456 C4071 118457 C4067 118458 C4073 118459 C4076 118461 C2830 128465 C2420 128466 C2412 128467 C2421 128468 C2423 128469 C2422 128471 C2405 138473 C2409 138477 C2410 138486 C2754 98488 C1130 1028489 C2404 128520 C7610 48521 C7608 48522 C7606 48523 C7604 48524 C7602 48525 C7600 48527 C7611 48612 C3521 60, 1188618 C2537 178619 C2424 128620 C2425 138620 C2425 138621 C2426 138622 C2427 138623 C2428 138624 C2429 138627 C2430 138628 C2431 138641 C2513 178649 C1360 153
BELDEN GC/CAROLPART NO. PART NO. PAGE NUMBER
8661 C2426 138690 C6103 318691 C6106 318692 C6109 318718 C2539 178719 C2536 178720 C2538 178722 C1331 1438723 C1352 368724 C1340 1438725 C1368 528728 C1353 368732 C1338 1448735 C2678 238737 C2882 218740 C4008 9, 308741 C4010 308747 C6017 308751 C6451 338757 C4015 308759 C2888 218760 C2534 178761 C2514 178762 C2524 178763 C1333 1428767 C6035 538768 C6036 538769 C6045 518770 C2535 178771 C2526 178772 C2528 178773 C6046 518774 C6042 518775 C6043 518776 C6044 518777 C6040 518778 C6041 518780 C2895 218782 C1356 1538786 C1345 1428790 C2892 218791 C2768 218795 C4408 85, 1038898 C1318 78899 C1321 78916 C2105 38917 C2104 38918 C2103 38919 C2102 38920 C2101 39011 C5034 639066 C5804 58
BELDEN GC/CAROLPART NO. PART NO. PAGE NUMBER
This cross reference guide should be used in conjunction with the product information in this catalog. It should beused for suggested alternative items which are functionally equal. Constructional differences are not indicated. GeneralCable is not responsible for variances due to competitor and industry constructional changes or agency updates.
Belden-to-General Cable Carol® Brand Cross Reference Index
231
Electronics Technical Information
9066 C5804 589067 C5844 699104 C5782 689105 C5842 699106 C5834 679108 C5832 689110 C5831 689114 C5774 579116 C5775 84, 57
9116P C3524 60, 84, 1189116R C5886 579117 C5802 589141 C5838 729154 E2022S 999155 C1343 1439155 C1343 1439156 C6118 319157 C6119 319159 C6120 319161 C6121 319161 C6121 319182 C8014 739201 C1117 659201 C1117 659243 C5782 689244 C5836 639248 C5778 609258 C1108 629259 C1103 66, 84, 1459265 C8025 67, 1459269 C1164 709271 C8012 739275 C5780 689291 C5770 689291 C5780 689292 C5033 649302 C1670 329305 C1676 329306 C1671 329309 C1672 329312 C0460 209314 C0458 209315 C1673 329316 C0456 209320 C0452 209322 C0450 209328 C0570 379329 C0571 379330 C0572 379331 C0573 379332 C0574 379363 C0451 20
BELDEN GC/CAROLPART NO. PART NO. PAGE NUMBER
9364 C0453 209365 C0455 209366 C0457 209367 C0459 209368 C0584 379369 C0585 379388 C0586 379389 C0587 379390 C0588 379397 C1226 1379406 C1350 359407 C0431 159408 C0433 159409 C0435 159410 C0437 159411 C0439 159412 C0441 159418 C2543 189421 C4065 119423 C4070 119430 C4088 119431 C4075 119432 C4077 119433 C4078 119434 C4079 119439 C6356 129444 C6353 129445 C6355 129451 C2520 199452 C1228 1389455 C6357 129458 C6358 129460 C2521 199461 C2518 199463 C8001 739464 C2519 199491 C0432 159492 C0434 159493 C0436 159494 C0438 159495 C0440 159501 C0600 449502 C0601 449503 C0602 449504 C0603 449505 C0604 449506 C0605 449507 C0606 449508 C0607 449509 C0608 449510 C0609 449512 C0550 34
BELDEN GC/CAROLPART NO. PART NO. PAGE NUMBER
This cross reference guide should be used in conjunction with the product information in this catalog. It should beused for suggested alternative items which are functionally equal. Constructional differences are not indicated. GeneralCable is not responsible for variances due to competitor and industry constructional changes or agency updates.
Belden-to-General Cable Carol® Brand Cross Reference Index
232
Technical Information Electronics
9513 C0551 349514 C0552 349515 C0610 449516 C0553 349519 C0611 449520 C0554 349525 C0612 449533 C0741 399534 C0742 399535 C0753 399536 C0743 399537 C0754 399538 C0744 399539 C0755 399540 C0745 399541 C0746 399542 C0747 399543 C0748 399544 C0749 399545 C0750 399546 C0751 399552 C0560 349553 C0561 349554 C0562 349555 C8005 679556 C0563 349559 C0564 349608 C0951 419609 C0952 419610 C0953 419611 C0954 419612 C0955 419613 C0956 419614 C0957 419615 C0958 419616 C0959 419617 C0961 419620 C2434 139621 C2435 139622 C2436 139623 C2437 139626 C2433 129637 C0948 419708 C1357 85, 1539712 C1362 85, 1539716 C1358 1539717 C1361 1539718 C1363 1539721 C2443 139728 C0912 549729 C0910 549730 C0911 54
BELDEN GC/CAROLPART NO. PART NO. PAGE NUMBER
9731 C0913 549732 C0914 549733 C0915 549734 C0916 549735 C0917 549740 C6101 319744 C6010 309745 C6014 309746 C6015 309768 C6059 519769 C6060 519770 C2517 179773 C6047 569774 C6048 519775 C6049 519776 C6050 519777 C6051 519791 C0533 439794 E1001S 989802 C2509 1469803 C2510 1469804 C0804 489805 C0805 489806 C0806 489807 C0807 489808 C0808 489812 C0812 489829 C0829 499830 C0830 499831 C0831 499832 C0832 499833 C0833 499835 C0835 499836 C0836 499839 C0839 499860 C8013 739862 C1162 709863 C8000 739873 C6052 519874 C6053 519875 C6054 519877 C6056 519879 C6058 519883 C6061 1479886 C6062 1479890 C2511 1469890 C2511 1469899 C1320 79899 C1320 79907 C5779 729910 C2107 39912 C2106 3
BELDEN GC/CAROLPART NO. PART NO. PAGE NUMBER
This cross reference guide should be used in conjunction with the product information in this catalog. It should beused for suggested alternative items which are functionally equal. Constructional differences are not indicated. GeneralCable is not responsible for variances due to competitor and industry constructional changes or agency updates.
Belden-to-General Cable Carol® Brand Cross Reference Index
233
Electronics Technical Information
9913 C1180 629916 C2065 29918 C2064 29919 C2040 29921 C2016 29923 C2015 29924 C2100 39925 C0680 439927 C0681 439929 C0682 439931 C0683 439932 C0684 439933 C0685 439934 C0686 439935 C0687 439936 C0688 439939 C0971 429940 C0972 429941 C0973 429942 C0974 429943 C0975 429944 C0976 429945 C0977 429946 C0978 429947 C0979 429948 C0981 429990 C6065 519991 C6066 519992 C6067 519999 C8033 73
BELDEN GC/CAROLPART NO. PART NO. PAGE NUMBER
This cross reference guide should be used in conjunction with the product information in this catalog. It should beused for suggested alternative items which are functionally equal. Constructional differences are not indicated. GeneralCable is not responsible for variances due to competitor and industry constructional changes or agency updates.
Belden-to-General Cable Carol® Brand Cross Reference Index
234
Technical Information Electronics
Part Number Index
05091 ..................10505092 ..................10505093 ..................10505094 ..................10505095 ..................10505096 ..................10505097 ..................10505098 ..................10505099 ..................10505481 ..................10605482 ..................10605483 ..................10605484 ..................10605485 ..................10605486 ..................10605487 ..................10605488 ..................10605489 ..................10605581 ..................10605582 ..................10605583 ..................10605584 ..................10605585 ..................10605586 ..................10605587 ..................10605588 ..................10605589 ..................10605782 ..................10705783 ..................10705784 ..................10705785 ..................10705786 ..................10705788 ..................1071001308 ..............1601003408 ..............1601004408 ..............1611005508 ..............1641005708 ..............1641006508 ..............1661015508 ..............1651051408 ..............1621053408 ..............1621063408 ..............1631103308 ..............1601105508 ..............1641106508 ..............1661153408 ..............1621163408 ..............16323804-18-01 .......10423805-18-01 .......10423807-18-01 .......10423810-18-01 .......10423815-60-01 .......10423817-60-01 .......10423824-60-01 .......10423825-60-01 .......10423827-60-01 .......104395006 ................128395007 ................128395009 ..................76395010 ................133395011 ................124395011-3.............122395011-4.............122395011-5.............122395013 ................133395014 ..................75395016 ..................82395020 ..................81395021 ................130395022 ..................76395024 ................129395025 ................133395025-3.............127
395025-4.............127395025-5.............127395025-10...........127395027 ..................83395028 ................129395029 ................125395030 ................130395031 ................133395031-3.............127395031-4.............127395031-5.............127395032 ................130395032-3.............132395032-4.............132395032-5.............132395035 ................130395035-3.............131395035-4.............131395035-5.............131395036 ................133395040 ................128395041 ................128395042 ................129395047 ................124395053 ..................76395056 ................122395057 ................125395058 ................125395059 ..................76395062 ..................76395159 ..................76397001 ..................77397002 ..................80397008 ..................78397009 ..................80397010 ..................83397011 ..................83397106 ..................78397107 ..................80397108 ..................78495010 ................134495011 ..................79495015 ................126495016 ................126495017 ..................75495023 ................134495024 ..................75495025 ................124495027 ................125495028 ................130495029 ..................76495035 ................123495036 ................123495044 ................130497001 ..................77497002 ..................80497022 ..................80497105 ..................78574608 ................120710010 ................168710011 ................168710017 ................168710018 ................168710021 ................168710022 ................168710023 ................168710024 ................168740002 ................152740004 ................152740102 ................152740104 ................152740202 ................152740204 ................152740302 ................152
740304 ................152740501 ................148740504 ................148740508 ................148740512 ................148740516 ................148740520 ................148740528 ................148740542 ................148740552 ................148740601 ................150740604 ................150740608 ................150740612 ................150740616 ................150740620 ................150740701 ................149740704 ................149740706 ................149740708 ................149740709 ................149740712 ................149740716 ................149740720 ................149740728 ................149740742 ................149740752 ................149740801 ................151740804 ................151740806 ................151740808 ................151740809 ................151740812 ................151740816 ................151740820 ................151740827 ................151742605 ................121742608 ................120743601 ................158743602 ................158743603 ................158743604 ................158743605 ................158743701 ................136743702 ................135743703 ................135743704 ................136743705 ................136743706 ................136743707 ................136743722 ................135743731 ................13576502 ......................576512 ......................576812 ......................576822 ......................576832 ......................576843 ......................576954 ......................676994 ......................6810021 ................168810022 ................168810023 ................168810024 ................168C0431....................15C0432....................15C0433....................15C0434....................15C0435....................15C0436....................15C0437....................15C0438....................15C0439....................15C0440....................15
C0441....................15C0444....................15C0450....................20C0451....................20C0452....................20C0453....................20C0454....................20C0455....................20C0456....................20C0457....................20C0458....................20C0459....................20C0460....................20C0471..............85, 93C0472..............85, 94C0473..............85, 93C0474..............85, 94C0475....................94C0476....................94C0485..............85, 93C0486....................93C0491....................93C0492....................93C0494..............85, 94C0495....................94C0496....................94C0497....................94C0515....................50C0516....................50C0517....................50C0518....................50C0519....................50C0520....................50C0521....................50C0522....................50C0523....................50C0524....................50C0525....................50C0526....................50C0530....................43C0531....................43C0532....................43C0533....................43C0534....................43C0535....................43C0536....................43C0537....................43C0538....................43C0539....................43C0550....................34C0551....................34C0552....................34C0553....................34C0554....................34C0555....................34C0556....................34C0560....................34C0561....................34C0562....................34C0563....................34C0564....................34C0566....................34C0570....................37C0571....................37C0572....................37C0573....................37C0574....................37C0575....................37C0584....................37C0585....................37C0586....................37C0587....................37C0588....................37C0589....................37
C0590....................37C0600....................44C0601....................44C0602....................44C0603....................44C0604....................44C0605....................44C0606....................44C0607....................44C0608....................44C0609....................44C0610....................44C0611....................44C0612....................44C0620....................46C0621....................46C0622....................46C0623....................46C0624....................46C0625....................46C0626....................46C0628....................46C0630....................46C0650....................46C0651....................46C0652....................46C0653....................46C0654....................46C0655....................46C0656....................46C0658....................46C0660....................46C0663....................46C0680....................43C0681....................43C0682....................43C0683....................43C0684....................43C0685....................43C0686....................43C0687....................43C0688....................43C0689....................43C0720....................44C0721....................44C0722....................44C0723....................44C0724....................44C0725....................44C0726....................44C0728....................44C0729....................44C0730....................44C0740....................39C0741....................39C0742....................39C0743....................39C0744....................39C0745....................39C0746....................39C0747....................39C0748....................39C0749....................39C0750....................39C0751....................39C0753....................39C0754....................39C0755....................39C0760....................40C0761....................40C0762....................40C0763....................40C0764....................40C0765....................40
C0766....................40C0767....................40C0768....................40C0780....................40C0781....................40C0782....................40C0783....................40C0784....................40C0785....................40C0786....................40C0787....................40C0788....................40C0804....................48C0805....................48C0806....................48C0807....................48C0808....................48C0809....................48C0810....................48C0812....................48C0829....................49C0830....................49C0831....................49C0832....................49C0833....................49C0835....................49C0836....................49C0839....................49C0841....................47C0842....................47C0843....................47C0844....................47C0890....................45C0893....................45C0894....................45C0896....................45C0897....................45C0899....................45C0901....................45C0910....................54C0911....................54C0912....................54C0913....................54C0914....................54C0915....................54C0916....................54C0917....................54C0924....................55C0925....................55C0926....................55C0939....................41C0940....................41C0941....................41C0942....................41C0943....................41C0944....................41C0945....................41C0946....................41C0947....................41C0948....................41C0951....................41C0952....................41C0953....................41C0954....................41C0955....................41C0956....................41C0957....................41C0958....................41C0959....................41C0960....................41C0961....................41C0971....................42C0972....................42C0973....................42
C0974....................42C0975....................42C0976....................42C0977....................42C0978....................42C0979....................42C0980....................42C0981....................42C1102....................66C1103......66, 84, 145C1104....................66C1106....................66C1107....................66C1108....................62C1110....................67C1112....................67C1117....................65C1118..................102C1119..................102C1123..................102C1124..................102C1126..................102C1130..................102C1135....................66C1142..............66, 84C1154....................62C1155....................65C1156....................71C1158....................69C1160....................63C1162....................70C1164....................70C1166....................65C1176....................71C1178....................65C1180....................62C1188....................65C1197....................62C1198....................62C1201..................141C1202............28, 141C1203....................28C1204....................28C1206....................28C1208....................28C1210....................28C1212....................28C1226..................137C1228..................138C1300..................140C1301..................140C1302............27, 140C1304....................27C1305....................27C1308....................27C1310....................27C1312....................27C1313....................27C1318......................7C1319......................7C1320......................7C1321......................7C1322..................139C1326......................7C1331..................143C1332....................23C1333..................142C1335....................21C1337....................21C1338..................144C1340..................143C1341....................21C1343..................143C1345..................142
C1350....................35C1352....................36C1353....................36C1356..................153C1357............85, 153C1358..................153C1360..................153C1361..................153C1362............85, 153C1363..................153C1364..................154C1368....................52C1458....................85C1458.15.90........156C1458.55.90........156C1458.56.90........156C1458.57.90........156C1461....................85C1461.15.90........156C1461.55.90........156C1461.56.90........156C1461.57.90........156C1463....................85C1463.15.90........156C1463.55.90........156C1463.56.90........156C1558.15.92........155C1561.15.92........155C1563.15.92........155C1602............28, 141C1603....................28C1604....................28C1606....................28C1608....................28C1612....................28C1614....................28C1642....................25C1643....................25C1644....................25C1645....................25C1646....................25C1648....................26C1670....................32C1671....................32C1672....................32C1673....................32C1676....................32C1700..................157C1701..................157C1702............85, 157C1703............85, 157C1704............85, 157C1705............85, 157C2003......................2C2004......................2C2015......................2C2016......................2C2028......................2C2040......................2C2052......................2C2053......................2C2064......................2C2065......................2C2100......................3C2101......................3C2102......................3C2103......................3C2104......................3C2105......................3C2106......................3C2107......................3C2117......................3C2118......................3C2119......................3
CAT.NO.
PAGENO.
CAT.NO.
PAGENO.
CAT.NO.
PAGENO.
CAT.NO.
PAGENO.
CAT.NO.
PAGENO.
CAT.NO.
PAGENO.
CAT.NO.
PAGENO.
CAT.NO.
PAGENO.
235
Electronics Technical Information
Part Number Index
C2404....................12C2405....................13C2406....................13C2409....................13C2410....................13C2412....................12C2420....................12C2421....................12C2422....................12C2423....................12C2424....................12C2425....................13C2426....................13C2427....................13C2428....................13C2429....................13C2430....................13C2431....................13C2433....................12C2434....................13C2435....................13C2436....................13C2437....................13C2440....................13C2443....................13C2461....................10C2462....................10C2463....................10C2464....................10C2465....................10C2466....................10C2467....................10C2470....................10C2471....................10C2473....................10C2488....................10C2509..................146C2510..................146C2511..................146C2513....................17C2514....................17C2515....................17C2516....................17C2517....................17C2518....................19C2519....................19C2520....................19C2521....................19C2523..............17, 84C2524....................17C2525....................17C2526....................17C2528....................17C2534....................17C2535....................17C2536....................17C2537....................17C2538....................17C2539....................17C2540....................17C2543....................18C2555....................17C2676....................22C2677....................22C2678....................23C2679....................23C2680....................23C2681....................23C2683....................23C2686....................23C2687....................23C2688....................23C2689....................23C2754......................9
C2768....................21C2830....................12C2831....................12C2882....................21C2888....................21C2892....................21C2895....................21C3028..................116C3029..................116C3030..................116C3031..................116C3060..................111C3061..................111C3062..................111C3063..................111C3064..................111C3065..................111C3068..................111C3102..................110C3103..................110C3105..................110C3106..................110C3110..................109C3111..................109C3112..................109C3113..................109C3114..................109C3115..................109C3116..................109C3117..................109C3118..................109C3119..................109C3120..................109C3121..................109C3122..................109C3123..................109C3124..................109C3125..................109C3126..................110C3127..................109C3128..................109C3129..................109C3134..................110C3135..................110C3150..................113C3151..................113C3152..................113C3153..................113C3154..................112C3155..................112C3156..................117C3157..................117C3158..................111C3159..................111C3162..................112C3163..................112C3164..................112C3165..................113C3166..................112C3167..............85, 96C3168..............85, 96C3169..................112C3170..............85, 96C3171....................96C3172....................96C3173....................96C3174....................96C3175....................96C3178..................110C3179..................110C3180..................112C3181..................112C3182..................112C3183..................111
C3184..................111C3190..................110C3191..................110C3192..................110C3193..................110C3194..................110C3195..................110C3200....................91C3201....................91C3204..................113C3205..................113C3206..................113C3207..................113C3208..................113C3210....................91C3211....................91C3214..................115C3215..................115C3216..................115C3217..................115C3218..................115C3220....................94C3223....................94C3224....................94C3225....................94C3240..............85, 95C3241..............85, 95C3242..............85, 95C3243....................95C3244....................95C3245....................95C3246....................95C3247....................95C3260....................92C3261....................92C3270....................92C3271....................92C3280....................92C3282....................92C3283....................92C3284....................92C3310..................112C3311..................112C3320..................112C3321..................112C3322..................112C3340..................112C3341..................112C3352..................114C3353..................114C3354..................114C3356..................114C3362..................114C3364..................114C3500......69, 84, 118C3519............65, 118C3520............70, 118C3521............60, 118C3523......60, 84, 118C3524......60, 84, 118C3525......60, 84, 118C3526............69, 118C3527............69, 118C3528............64, 118C3529............64, 118C3579............72, 118C3602....................16C3603....................16C3604....................16C3605....................16C3606....................16C3607....................16C3608....................16C3610....................16
C3P002..................84C3P004..................84C3R002 .................84C3R004 .................84C4008................9, 30C4010....................30C4014....................30C4015....................30C4017....................30C4062....................11C4063....................11C4064....................11C4065....................11C4066....................11C4067....................11C4070....................11C4071....................11C4073....................11C4075....................11C4076....................11C4077....................11C4078....................11C4079....................11C4080..................102C4081....................14C4082....................14C4083....................14C4084....................14C4088....................11C4090..................102C4100..................173C4101..................173C4102..................173C4103..................173C4104..................173C4105..................173C4106..................173C4107..................173C4108..................173C4109..................173C4110..................173C4111..................173C4112..................173C4113..................173C4114..................173C4115..................173C4116..................173C4117..................174C4118..................174C4119..................174C4120..................174C4121..................174C4122..................174C4123..................174C4124..................174C4125..................174C4126..................174C4127..................174C4128..................174C4129..................174C4130..................174C4131..................174C4132..................174C4133..................174C4134..................174C4135..................175C4136..................175C4137..................175C4138..................175C4139..................175C4140..................175C4141..................175C4142..................175C4143..................175
C4144..................175C4145..................175C4146..................175C4147..................175C4148..................175C4149..................175C4150..................175C4151..................175C4152..................176C4153..................176C4154..................176C4155..................176C4156..................176C4157..................176C4158..................176C4159..................176C4160..................176C4161..................176C4162..................176C4163..................176C4164..................176C4165..................176C4166..................177C4167..................176C4168..................176C4169..................176C4170..................178C4171..................178C4172..................178C4173..................178C4174..................178C4175..................178C4176..................178C4177..................178C4178..................178C4179..................178C4180..................178C4181..................178C4182..................178C4183..................179C4184..................179C4185..................179C4186..................179C4187..................179C4188..................179C4189..................179C4190..................179C4191..................178C4192..................177C4193..................177C4194..................177C4195..................177C4196..................177C4197..................177C4198..................177C4199..................177C4200..................177C4201..................177C4202..................177C4203..................181C4204..................177C4205..................177C4206..................174C4207..................177C4208..................177C4209..................178C4210..................177C4211..................177C4212..................177C4213..................177C4214..................174C4215..................177C4216..................180C4217..................180
C4218..................180C4219..................180C4220..................180C4221..................180C4222..................180C4223..................180C4224..................180C4225..................180C4226..................180C4227..................180C4228..................180C4229..................180C4230..................180C4311......................9C4408............85, 103C4408ST..............103C4410..................103C4412............85, 103C4412ST..............103C4413..................103C4841....................47C4842....................47C4843....................47C4844....................47C5011....................63C5025....................63C5027....................64C5029....................64C5033....................64C5034....................63C5039....................63C5041....................64C5043....................64C5044....................63C5045....................65C5076..................102C5078..................102C5084..................102C5086..................102C5096..................102C5460..................102C5760....................57C5761..............57, 84C5770....................68C5774....................57C5775..............57, 84C5776....................57C5777....................58C5778....................60C5779....................72C5780....................68C5782....................68C5784....................68C5785..............58, 84C5802....................58C5804....................58C5810....................58C5812....................59C5814....................59C5816....................67C5822....................59C5824....................59C5826....................59C5830....................68C5831....................68C5832....................68C5834....................67C5836....................67C5838....................72C5842....................69C5844....................69C5851....................61C5853....................61C5856....................61
C5857....................61C5886....................57C5888....................58C5889..............58, 84C5890....................59C5910....................84C5P004..................84C5R004 .................84C6010....................30C6014....................30C6015....................30C6017....................30C6019....................30C6023....................30C6026....................30C6035....................53C6036....................53C6040....................51C6041....................51C6042....................51C6043....................51C6044....................51C6045....................51C6046....................51C6047....................51C6048....................51C6049....................51C6050....................51C6051....................51C6052....................51C6053....................51C6054....................51C6056....................51C6058....................51C6059....................51C6060....................51C6061..................147C6062..................147C6065....................51C6066....................51C6067....................51C6101....................31C6103....................31C6106....................31C6109....................31C6111....................31C6118....................31C6119....................31C6120....................31C6121....................31C6310..................103C6311..................103C6312..................103C6313..................103C6348....................11C6351....................12C6352....................12C6353....................12C6355....................12C6356....................12C6357....................12C6358....................12C6360....................12C6367..................154C6451....................33C6500....................24C6501....................24C6502....................24C6503....................24C6504....................24C6505....................24C6506....................24C6507....................24C6508....................24
C6P004..................84C6R004 .................84C7600......................4C7602......................4C7604......................4C7606......................4C7608......................4C7610......................4C7611......................4C8000....................73C8001....................73C8005....................67C8012....................73C8013....................73C8014....................73C8025............67, 145C8027......69, 84, 145C8028......69, 84, 145C8029......60, 84, 145C8030............66, 145C8031............60, 145C8033....................73E024C0045510....171E026C0045510....171E028C0045510......17E028PO131510 ...171E028PO181510 ...171E028PO251510 ...171E028PO252510 ...171E028PO252540 ...171E028PO253510 ...171E028PO253520 ...171E028PO341510 ...171E028PO342510 ...171E028PO342540 ...171E028PO343510 ...171E028PO343520 ...171E028PO501510 ...171E030C0045510....171E030PO252540 ...171E030PO253520 ...171E030PO342540 ...171E030PO343520 ...171E1000S..................98E1001S..................98E1002S............85, 98E1003S..................98E1004S............85, 98E1006S............85, 98E1008S............85, 98E1010S..................98E1012S..................98E1022S..................98E1023S..................98E1024S..................98E1030S..................98E1032S............85, 98E1033S..................98E1034S............85, 98E1036S..................98E1038S..................98E1040S..................98E1041S..................98E1042S............85, 98E1043S..................98E1044S............85, 98E1052S............85, 98E1054S............85, 98E1062S............85, 98E1064S............85, 98E1482S..................87E1484S..................87E1486S..................87E1502S............85, 87
CAT.NO.
PAGENO.
CAT.NO.
PAGENO.
CAT.NO.
PAGENO.
CAT.NO.
PAGENO.
CAT.NO.
PAGENO.
CAT.NO.
PAGENO.
CAT.NO.
PAGENO.
CAT.NO.
PAGENO.
236
Technical Information Electronics
Part Number Index
CAT.NO.
PAGENO.
CAT.NO.
PAGENO.
CAT.NO.
PAGENO.
CAT.NO.
PAGENO.
CAT.NO.
PAGENO.
CAT.NO.
PAGENO.
CAT.NO.
PAGENO.
CAT.NO.
PAGENO.
E1503S..................87E1504S............85, 87E1505S..................87E1506S..................87E1508S..................87E1512S..................87E1514S..................87E1522S............85, 87E1524S............85, 87E1532S..................87E1534S..................87E2000S..................99E2002S............84, 99E2003S..................99E2004S............84, 99E2006S............84, 99E2008S............84, 99E2010S............84, 99E2012S............84, 99E2022S..................99E2023S..................99E2024S..................99E2030S..................99E2032S............84, 99E2033S..................99E2034S............84, 99E2036S............84, 99E2038S............84, 99E2040S..................99E2041S..................99E2042S..................99E2043S..................99E2044S..................99E2052S..................99E2054S..................99E2062S..................99E2064S..................99E2100S................101E2102S..........84, 101E2103S................101E2104S..........84, 101E2106S..........84, 101E2108S..........84, 101E2122S................101E2123S................101E2124S................101E2200S................101E2202S..........84, 101E2203S................101E2204S..........84, 101E2206S..........84, 101E2208S..........84, 101E2242S................101E2243S................101E2244S................101E2252S................101E2254S................101E2262S................101E2264S................101E2402S..................87E2404S..................87E2406S..................87E2482S..................87E2484S..................87E2502S............85, 88E2503S..................88E2504S............85, 88E2506S..................88E2508S..................88E2522S..................88E2524S..................88E2532S............85, 88E2534S............85, 88E2542S..................88
E2544S..................88E3000S................100E3001S................100E3002S..........85, 100E3003S................100E3004S..........85, 100E3006S..........85, 100E3008S..........85, 100E3010S................100E3012S................100E3022S................100E3023S................100E3024S................100E3030S................100E3032S..........85, 100E3033S................100E3034S..........85, 100E3036S................100E3038S................100E3042S..........85, 100E3043S................100E3044S..........85, 100E3052S..........85, 100E3054S..........85, 100E3062S..........85, 100E3064S..........85, 100E3482S..................89E3484S..................89E3502S............85, 89E3503S............85, 89E3504S............85, 89E3506S..................89E3512S..................89E3514S..................89E3522S............85, 89E3524S............85, 89E3532S..................89E3534S..................89E3542S..................90E3602S............85, 90E3603S..................90E3604S............85, 90E3606S..................90E3612S..................90E3614S..................90E3622S............85, 90E3624S............85, 90E3632S..................90E3634S..................90SP00C0011010 ...169SP00C0012010 ...169Z028C0042010....171Z028C0042210....171Z028C0042410....171Z028C0042610....171Z028C0042810....171Z028C0061110....170Z028C0066110....171Z028C0101120....171Z028C0130532....171Z030C0105510....171Z030C0111110....171Z030C0145510....171Z030C0165510....171Z030C0285510....171ZF28C0130532 ....171