Programmable Programmable Biofeedback Chest Biofeedback Chest Exerciser Exerciser Group 23: Group 23: Eileen Bock, Lauren Cassell, Eileen Bock, Lauren Cassell, Margaret Gipson, Laurie McAlexander Margaret Gipson, Laurie McAlexander Advisors: Advisors: Douglas Sawyer, M.D., Ph.D. Douglas Sawyer, M.D., Ph.D. Paul King, Ph.D. Paul King, Ph.D. John Newman, M.D. John Newman, M.D.

Programmable Biofeedback Chest Exerciser

Embed Size (px)

DESCRIPTION

Programmable Biofeedback Chest Exerciser. Group 23: Eileen Bock, Lauren Cassell, Margaret Gipson, Laurie McAlexander Advisors: Douglas Sawyer, M.D., Ph.D. Paul King, Ph.D. John Newman, M.D. Heart Failure and Its Treatment. Pathology Heart doesn’t pump nutrients to - PowerPoint PPT Presentation

Citation preview

Page 1: Programmable Biofeedback Chest Exerciser

Programmable Programmable Biofeedback Chest Biofeedback Chest

ExerciserExerciserGroup 23:Group 23:

Eileen Bock, Lauren Cassell, Eileen Bock, Lauren Cassell, Margaret Gipson, Laurie McAlexanderMargaret Gipson, Laurie McAlexander

Advisors:Advisors:Douglas Sawyer, M.D., Ph.D.Douglas Sawyer, M.D., Ph.D.

Paul King, Ph.D.Paul King, Ph.D.John Newman, M.D.John Newman, M.D.

Page 2: Programmable Biofeedback Chest Exerciser

Heart Failure and Its Heart Failure and Its TreatmentTreatment

StatisticsStatistics Affects 5 million AmericansAffects 5 million Americans 50% mortality rate within 4 50% mortality rate within 4

years of diagnosisyears of diagnosis

PathologyPathologyHeart doesn’t pump nutrients Heart doesn’t pump nutrients to to tissues efficientlytissues efficientlyHeart can’t develop pressure Heart can’t develop pressure toto eject needed stroke volumeeject needed stroke volume

•Benefits of exercise as Benefits of exercise as treatmenttreatment

•Improves vascular functionImproves vascular function•Improves muscle functionImproves muscle function•Reduces arrythmia riskReduces arrythmia risk

•Benefits of deep breathing Benefits of deep breathing as as exerciseexercise

•Targets muscles of chest Targets muscles of chest wallwall•Not as difficult for patientsNot as difficult for patients

Page 3: Programmable Biofeedback Chest Exerciser

Current DevicesCurrent Devices

Incentive SpirometerIncentive Spirometer Problems: Problems:

Must be stationary Must be stationary

during useduring use Large, awkward shapeLarge, awkward shape

PneumotracePneumotrace Problems:Problems:

Must be lying down for useMust be lying down for use Very complex deviceVery complex device

Page 4: Programmable Biofeedback Chest Exerciser

Current DevicesCurrent Devices

RESPeRATERESPeRATE Problems:Problems:

Must wear headphonesMust wear headphones Must carry additional deviceMust carry additional device

VivoMetrics LifeShirtVivoMetrics LifeShirt Problems:Problems:

Large DeviceLarge Device Uncomfortable to wearUncomfortable to wear Very conspicuousVery conspicuous

Page 5: Programmable Biofeedback Chest Exerciser

Our SolutionsOur Solutions

Will be smallWill be small Can be worn inconspicuously under Can be worn inconspicuously under

clothingclothing Can be worn during dailyCan be worn during daily

activities activities Will be incorporated into Will be incorporated into

a PDAa PDA

Page 6: Programmable Biofeedback Chest Exerciser

ApplicationsApplications

Daily WearDaily Wear Measure breathing rateMeasure breathing rate Measure patient’s compliance Measure patient’s compliance with pre-programmed breathing with pre-programmed breathing exercisesexercises

Exercise WearExercise Wear Measure breathing rateMeasure breathing rate Indicate when the user reaches a proper Indicate when the user reaches a proper

range for beneficial aerobic activityrange for beneficial aerobic activity

Page 7: Programmable Biofeedback Chest Exerciser

ApproachApproach

BridgeBridge Differential Differential

amplifieramplifier Bend SensorBend Sensor Voltage threshold Voltage threshold

detectordetector

RRss/R/R22=R=R33/R/R11

Page 8: Programmable Biofeedback Chest Exerciser

DesignDesign

Needed components:Needed components: Adjustable inelastic Adjustable inelastic

bandband Elastic sectionElastic section Strain gauge/bend Strain gauge/bend

sensorsensor PDA for digital PDA for digital

outputoutput DAQ systemDAQ system Motor for vibrationMotor for vibration

Acquired Acquired components:components:

Voltage sourceVoltage source Low power Low power

Operational Operational AmplifierAmplifier

Page 9: Programmable Biofeedback Chest Exerciser

TestingTesting

Part 1Part 1 10 subjects wear 10 subjects wear

the device for 1 the device for 1 hour eachhour each

Subject will Subject will perform breathing perform breathing exercises and exercises and various common various common activitiesactivities

Subject surveySubject survey

Part 2Part 2 Previous 10 Previous 10

subjects will return subjects will return and wear device and wear device for 3 hoursfor 3 hours

Subject surveySubject survey

Page 10: Programmable Biofeedback Chest Exerciser

TestingTestingPart 3Part 3 Clinical testing: requires another Clinical testing: requires another

IRB protocol submissionIRB protocol submission 2 control groups, 1 experimental 2 control groups, 1 experimental

groupgroup Measure improvement of negative Measure improvement of negative

inspiratory force with incentive inspiratory force with incentive spirometerspirometer

Page 11: Programmable Biofeedback Chest Exerciser

Tidal Volume ExperimentsTidal Volume Experiments

Determine Determine relationship between relationship between chest circumference chest circumference and lung volumeand lung volume

Determine the output Determine the output voltage of the device voltage of the device during a normal and during a normal and a deep breatha deep breath

Measurements used Measurements used to adjust resistor to adjust resistor ratings and gainratings and gain

Page 12: Programmable Biofeedback Chest Exerciser

Expected ResultsExpected Results

Output voltage correlates to lung volumeOutput voltage correlates to lung volume Deep breath threshold will correspond to Deep breath threshold will correspond to

a given output voltagea given output voltage If threshold not reach in a predetermined If threshold not reach in a predetermined

time period, alarm will soundtime period, alarm will sound Expect that the use of this device will Expect that the use of this device will

increase lung capacity and force of increase lung capacity and force of expiration from lungsexpiration from lungs

Page 13: Programmable Biofeedback Chest Exerciser

ResourcesResources

REST1 Impedance Pmeumograph by UFI. REST1 Impedance Pmeumograph by UFI. http://www.ufiservingscience.com/ DSRsp11.htmlhttp://www.ufiservingscience.com/ DSRsp11.html

"How to Use an Incentive Spirometer". The Cleveland Clinic "How to Use an Incentive Spirometer". The Cleveland Clinic Foundation. Foundation. <http://www.clevelandclinic.org/health/health-info/docs/0200/0239<http://www.clevelandclinic.org/health/health-info/docs/0200/0239.asp?index= 4302& src=news>. .asp?index= 4302& src=news>.

"Anaesthesia Products," Lifeline Systems Pvt. Ltd. "Anaesthesia Products," Lifeline Systems Pvt. Ltd. <http://www.lifelinedelhi.com/ catheter-mount.html><http://www.lifelinedelhi.com/ catheter-mount.html>

"RESPeRATE High Blood Pressure and Hypertension." Buyamag. "RESPeRATE High Blood Pressure and Hypertension." Buyamag. <http://www.buyamag.com/high_blood_pressure_hypertension.ph<http://www.buyamag.com/high_blood_pressure_hypertension.php>.p>.

"Smart textiles at Hightex 2005". Hightex 2005. "Smart textiles at Hightex 2005". Hightex 2005. <http://www.hightex2005.com/smart_textiles.htm>.<http://www.hightex2005.com/smart_textiles.htm>.

““Learning to Whistle”. November 2005. Learning to Whistle”. November 2005. <http://learningtowhistle.blogspot.com/2005_11_01_learningtowhi<http://learningtowhistle.blogspot.com/2005_11_01_learningtowhistle_archive.html>.stle_archive.html>.

http://www.answers.com/topic/lung http://www.answers.com/topic/lung