Upload
others
View
5
Download
0
Embed Size (px)
Citation preview
Project:
Architect Contact Information & Seal:
STOA STUDIOSArchitect
52 Riley Rd Ste 374Celebration, FL 34747(407) [email protected] Lic. #RA014339
Sheet:
Drawing:
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
Issue:
Ten
ant Im
prov
emen
t
© 2
017
by St
oa St
udio
s, al
l righ
ts re
serv
ed. A
ll dra
win
gs, il
lustr
atio
ns, id
eas,
and
othe
r info
rmat
ion
cont
aine
d on
this
shee
t are
the
prop
erty
of S
toa
Stud
ios a
nd m
ay n
ot b
e re
prod
uced
eith
er w
holly
or in
par
t in
any
man
ner w
ithou
t the
exp
ress
writ
ten
cons
ent o
f Sto
a St
udio
s.
Engineer Contact Information & Seal:
Gov
erne
r's Sq
uare
Mal
l • S
uite
#10
70 •
Tal
laha
ssee
, Flo
rida
Architect:
S T O AStudios
TECT
E
AR
C
HIU
TUD
ISS
TO
AS
O
R
REVIEW SET 21 JUL 2017
EPG ENGINEERINGEngineer
1325 S. Bumby AveOrlando, FL 32806(407) [email protected] Lic. #PE43599FL Lic. #PE72998
REVIEW SET 25 JUL 2017PERMIT SET 14 AUG 2017
Tenant Improvement
AAEQ Architect Approved EqAB Anchor BoltACT Acoustical Ceiling TileA/C Air ConditioningAFF Above Finish FloorALUM AluminumBLDG BuildingBLK Block(ing)B/ Bottom ofCEM CementCOL ColumnCONC ConcreteCONT ContinuousDF Drinking FountainDIM DimensionDET DetailDWG DrawingEA EachELEC Electric(al)EL ElevationEQ EqualEVTR ElevatorEWC Electric Water CoolerEXH ExhaustEXP ExposedFC Fixture ContractorFD Floor DrainFIN FinishFOC Face of ConcreteFOM Face of MasonryGA GaugeGC General ContractorGYP GypsumHB Hose BibbHCM Hollow Core MetalHDWR HardwareHM Hollow Core MetalHORIZ HorizontalHTG HeatingHT HeightID Inside DiameterINSUL InsulationINT InteriorJST JoistLAV LavatoryLAM LaminatedLH Left HandLWT Light WeightLL LandlordMECH MechanicalMFG ManufacturerMH Man HoleMISC MiscellaneousMO Masonry OpeningNC Non-combustibleNIC Not in ContractNTS Not to ScaleOA OverallOC On CenterOD Outside Diameter
OPNG OpeningPVC Polyvinyl ChoridePL Property LineRA Return AirRCP Reinf. Conc. PipeREINF ReinforcedRH Right HandRO Rough OpeningROW Right-of-WaySC Solid CoreSCHED ScheduleSHT SheetSIM SimilarSPEC SpecificationsSQ SquareSTL SteelSTRUCT StructuralTEL TelephoneTHK ThicknessTHRES ThresholdT/ Top ofTYP TypicalVERT VerticalWSCT WainscotWC Water ClosetWWF Welded Wire FabricW/ With
ABBREVIATIONS
GENERAL NOTES
1. Architect does not have control over and will not be responsible for construction means, methods,techniques, sequences, procedures, or for safety precautions and programs in connection withthe work. Architect will not be responsible for failure by contractor or others to carry out the work inaccordance with the contract documents. Architect will not be responsible for or have controlover the acts or omissions of the General Contractor or others.
2. All codes having jurisdiction shall be observed strictly in the construction of the project, includingall applicable state, city, and county building, zoning, electrical, mechanical, plumbing, and firecodes. GC shall verify all code requirements prior to construction. In the event of a conflictbetween the contract documents and the applicable code requirements, code requirementsshall prevail.
3. In the event that errors and/or omissions are discovered in the contract documents, they shall bebrought to the attention of the architect for clarification and/or correction. GC will be heldresponsible for the results of any errors, discrepancies, or omissions which the GC failed to notifythe Architect of before construction and/or fabrication of the work.
4. Architect has designed in accordance with American Disabilities Act; upon occupancy Tenantcompliance with said Act shall include (but to be limited to) design, construction, and/oralterations to the premises.
GENERAL CONTRACTOR / SUBCONTRACTORS
1. GC shall coordinate its work with that of the utility companies and all trades. GC shall provideaccess as required.
2. GC shall locate all existing utility service lines and protect them throughout construction.3. GC shall layout work and be responsible for all lines, elevations, measurement of the building,
utilities, and other work executed under the contract.4. Time is of the essence and subcontractors shall keep sufficient personnel on the job at all times to
perform all work in the most expeditious manner consistent with good workmanship and businesspractice.
5. Subcontractor shall examine existing utility conditions, stub-ins, and/or access to utilities and verifywith information on these drawings. Any discrepancies shall be brought to the attention of GC.
6. Upon completion of the work, GC shall have all surfaces professionally cleaned and made readyto use. GC shall remove all construction rubbish, scaffolding, equipment, temporary protection,temporary field structures, and anything else that was required in connection with theconstruction but not a permanent part thereof.
7. GC shall be responsible for removal of debris for all trades, and for keeping the job site clean.8. GC shall leave the construction dumpster on site after substantial completion to allow retail
operations to dispose of merchandising trash during initial stocking of the store.9. All work shall be performed as to cause a minimum of interference with any other tenants and the
operation of the Landlord's entire premises. GC shall take all precautionary steps to protect thefacilities on the premises and the facilities of others affected by performance of the work.
10. Construction equipment and materials are to be located in confined areas; truck traffic to berouted in and from the site as directed by Landlord. Cost of work shall include overtimenecessitated by these requirements.
11. GC shall arrange, pay for, and maintain any needed temporary facilities at the premisesincluding: electrical service, trash removal, protection, enclosure barricade, use of elevators, airconditioning, and heating at the premises for the duration of the work.
12. GC shall keep a complete set of the drawings, including approved shop drawings, at the job sitefor the duration of the work. Copies or originals of all permits and approvals shall also be kept at atthe job site for the duration of the work.
13. GC shall possess a complete set of the most current construction documents, and provide copiesto all subcontractors.
14. GC shall review with the Landlord's representative the manner in which all connections to thestructure will be made. Any penetrations in the building envelope or structure shall be reviewedwith the Landlord and approved in writing.
15. During performance of work, subcontractors are responsible for provision and maintenance ofwarning signs, light signal devices, guard lights, barricades, guard rails, fences, and other devicesas appropriately located on and around the job site which will give proper and understandablewarning to all persons with regard to hazardous conditions, equipment, and operations beingperformed in conjunction with the subcontractor's work. All warning devices shall comply withO.S.H.A. and other applicable governmental regulations as required for the constructionprocedures and conditions encountered.
16. GC shall carry all necessary insurance as required by law and hold harmless the Owner and/orArchitect from any loss, liability, claim or demand for damages arising out of or relating to theperformance of the work as described by these drawings.
17. GC shall guarantee all work specified and/or described by these drawings free from any defectsor malfunctions for one year from the substantial completion date or from the time of occupancy,whichever comes first. GC is responsible for all work executed by subcontractors.
18. GC shall coordinate fire protection work with Landlord's preferred subcontractor.
CONSTRUCTION
1. All cutting, drilling, or removals required shall upon completion be repaired, patched, and finishedon all surfaces to new condition by subcontractors.
2. All floor cuts/penetrations shall be termite treated by a licensed exterminator.3. All reused material & equipment must be refurbished to 'like-new' condition.4. The Tenant shall not permit the installation or use of any hazardous substances in any component
of the premises during its tenancy.5. There shall be no substitution of materials where a manufacturer is specified. Where the term 'or
approved equal' is used, the Architect alone shall determine suitability.6. All work shall be erected and installed plumb, level, square, true, and in proper alignment.7. Applicable standards of the construction industry have the same force and effect on
performance of work as if incorporated directly into these construction document. Complianceshall be with the standards in effect as of the date of these construction documents U.O.N.
8. These General Conditions shall apply to all work and all drawings in this set, and shall extend toany changes, extras, or additions agreed to during the course of the work.
GENERAL CONDITIONS
SYMBOL LEGEND
#X-###
#X-###
#
Drawing Reference
CROSS REFERENCE
Sheet Number
Drawing Reference
SECTION/ELEVATION
Sheet Number
REVISION
Revision Area
General Reference
Door Reference
Finish Reference
Furn/Equip Reference
Window Reference
KEYNOTE SYMBOLS
ELEVATION TAG
#'-#" ReferenceWorking Point
ENLARGEMENT
Drawing
Enlargement
Wall Type Reference
Governer's Square Mall • Suite #1070 • Tallahassee, Florida
PROJECT LOCATION MAP • SITE
PROJECT DIRECTORY
OWNER
PS Imports FL, Inc.P.O. Box 8115Santurce, PR 00910(787) 420-8200
LANDLORD
General Growth Properties10300 Little Patuxent ParkwayColumbia, Maryland 21044(410) 992-6045
ARCHITECT
Stoa Studios52 Riley Rd Ste 374Celebration, FL 34747(407) 749-0789
ENGINEER
EPG Engineering1325 S. Bumby AveOrlando, FL 32806(407) 896-7411
STATEMENT OF CODE COMPLIANCE
It is the intent of Architect to comply fully with the 2014 Florida Building Code(FBC) to the best of Architect's interpretation and ability, and it is Architect'sunderstanding that the drawings and specifications for this design are incompliance with said regulations. In the event that portion(s) of thesedrawings and/or specifications are found to be non-compliant with anyportions of said regulations, notify Architect prior to commencement ofassociated work.
REGULATION SUMMARY
JURISDICTION
City of TallahasseeGrowth Management - Building Permitting435 N. Macomb StTallahassee, FL 32301(850) 891-7001
APPLICABLE CODES
BUILDING: 2014 FBCELECTRICAL: 2011 NECMECHANICAL: 2014 FBC MechanicalPLUMBING: 2014 FBC PlumbingENERGY: 2014 FBC EnergyACCESSIBILITY: 2014 FBC AccessibilityFIRE: 2014 FFPC (5th Edition)
BUILDING DATA
OCCUPANCY: Group M: MercantileCONSTRUCTION: Type IIB | Non-combustible | Fully sprinkleredGROSS AREA 929 sf SALES AREA 777 sf STOCKROOM 092 sf RESTROOM 060 sf
OCCUPANT LOAD 28 persons SALES AREA 26 persons (030sf/occupant) STOCK 01 persons (300sf/occupant) RESTROOM 01 persons (100sf/occupant)
ALTERATION LEVEL: Level 2ADJACENT OCCUP: Group M: MercantileFIRE SEPARATION: No separation required
DRINKING FOUNTAIN: 290lf to public drinking fountainsRESTROOMS: Tenant's restroom is for staff only
290lf to nearest public restrooms
DRAWING INDEX
GENERAL
IDX PROJECT INDEX
ARCHITECTURAL
A001 CODE & LIFE SAFETYA002 LISTED UL DETAILSA003 SPECS • ARCHITECTURAL • 1A101 PLAN • FLOOR & CEILINGA102 PLAN • FIXTURE & FINISHA701 ELEVATIONS • STOREFRONTA702 ELEVATIONS • INTERIOR
PROJECT DESCRIPTION
PROJECT LOCATION MAP • MALL
#
#
X-#
#
#
##
SCALE: Varies
IDX
PROJECT INDEX
REVI
EW SE
T
RESTROOM/FOUNTAIN LOCATION
21 JU
L 201
7
SPACE #1070
290FT TO EXISTING
PUBLIC RESTROOMS &
DRINKING FOUNTAIN
MALL LOCATION
GENERAL
These drawings propose interior renovations to an existing tenant suite within a covered shopping mall.The scope of work is primarily cosmetic, as identified in the Finish Schedule and Fixture Plan. In addition,the following more substantial improvements are proposed:
ARCHITECTURAL
In addition to general cosmetic and fixture updates, the following architectural improvements areproposed:
1. Select portions of the storefront are proposed to be re-clad.2. The storefront signage and graphics are proposed to be replaced.
MECHANICAL / FIRE / PLUMBING / ELECTRICAL
No mechanical, fire, or plumbing work is proposed.REVI
EW SE
T25
JUL 2
017
PERM
IT SE
T14
AUG
201
7
REVISION SUMMARY
REVI
SION
13
JAN
2017
1
ISSUE DESCRIPTION OF REVISION(S) SHEET REFERENCE
-
REF#
Removed all improvements related to the ceiling, ceiling IDX, A101, A702now proposed to be left entirely as-is
SCALE: 1/2" = 1'-0"
A702
INTERIOR ELEVATIONS
Project:
Architect Contact Information & Seal:
STOA STUDIOSArchitect
52 Riley Rd Ste 374Celebration, FL 34747(407) [email protected] Lic. #RA014339
Sheet:
Drawing:
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
Issue:
Ten
ant Im
prov
emen
t
© 2
017
by St
oa St
udio
s, al
l righ
ts re
serv
ed. A
ll dra
win
gs, il
lustr
atio
ns, id
eas,
and
othe
r info
rmat
ion
cont
aine
d on
this
shee
t are
the
prop
erty
of S
toa
Stud
ios a
nd m
ay n
ot b
e re
prod
uced
eith
er w
holly
or in
par
t in
any
man
ner w
ithou
t the
exp
ress
writ
ten
cons
ent o
f Sto
a St
udio
s.
Engineer Contact Information & Seal:
Gov
erne
r's Sq
uare
Mal
l • S
uite
#10
70 •
Tal
laha
ssee
, Flo
rida
Architect:
S T O AStudios
TECT
E
AR
C
HIU
TUD
ISS
TO
AS
O
R
REVIEW SET 21 JUL 2017
EPG ENGINEERINGEngineer
1325 S. Bumby AveOrlando, FL 32806(407) [email protected] Lic. #PE43599FL Lic. #PE72998
REVIEW SET 25 JUL 2017PERMIT SET 14 AUG 2017
PAINTED PINE WALL BASE
WF08-96
0606 06
ELEVATION KEYNOTESADDITIONAL INFORMATION
01
03
STOREFRONT CLADDING • BULKHEADNew 1" thick (actual) MDF panel @ bulkhead with continuous wave style relief;provide 1 1/2" thick (actual) perimeter trim per elevation; paint entire assemblyand all existing storefront components with new finish per A102
02
NEW STOREFRONT SIGNAGE14"H x 3"D aluminum channel letters pin-mounted to bulkhead; gloss black finish
04
05
06
WALL BASE1x6 painted pine wall base; clear-grade w/out knots; see Finish Schedule
07
WALL GRAPHICSAll wall graphics are vinyl prints adhered directly to wall by graphic vendor;Owner/Tenant to provide actual graphic files to GC/Vendor for production
09
FITTING MIRROR12"W x 72"H x 1/4" glass mirror, fastened directly to existing pier
DISPLAY SHELVINGCantilevered open shelving, laminate finish per Finish Schedule; 30"L x 12"D x 2"H,see elevation for vertical spacing of individual shelves
STOREFRONT CLADDING • END WALLSNew 1" thick (actual) MDF panel @ each end wall, with continuous wave stylerelief, installed around existing graphic display boxes; paint with new finish perA102
NEW STOREFRONT GRAPHICSReplace existing graphics in storefront display boxes with new graphics; Ownerto provide digital files to GC for creation of the graphics
08
EXISTING WALL REVEALExisting 3/4" aluminum reveal along perimeter of storefront @ Landlord'sbulkhead and @ Landlord's neutral piers
WF08-84 WF08-72
1'-0"
1'-6"
1'-6"
1'-6"
1'-6"
1'-6"
8'-6"
8'-6"
7'-0" 6'-0"8'-0"
B/ EXISTING CEILING • EL. 11'-0"
11'-0
"
T/ EXISTING FLOOR SLAB • EL. 0'-0"
ft
ELEVATION • INTERIOR • REAR LEFT
8421
Scale: 1/4" = 1'-0"03A702
ft
ELEVATION • INTERIOR • REAR RIGHT
8421
Scale: 1/4" = 1'-0"01A702
8'-6"
8'-6"
ft
ELEVATION • INTERIOR • FRONT LEFT
8421
Scale: 1/4" = 1'-0"02A702
ft
ELEVATION • INTERIOR • FRONT RIGHT
8421
Scale: 1/4" = 1'-0"04A702
WF08-108 WF08-108 VICT-65
9'-0" 9'-0" 5'-5"
1'-0"
SHELF
SHELF
SHELF
SHELF
SHELF
SHELF
SHELF
SHELF
SHELF
SHELF
SHELF
SHELF
1'-0"
1'-6"
1'-6"
1'-6"
1'-6"
1'-6"
SHELF
SHELF
SHELF
SHELF
SHELF
SHELF
8'-6"
8'-6"
PAINTED PINE WALL BASE
8'-6"
3'-9"
EXISTING STOREFRONT BASE
EXISTING STOREFRONT GLASS
VICT-45
2'-0"
3'-4" 11'-6"
WF08-138
0606
06 06 06 06
EXIST.STRFRNTGLASS
2'-0"
2'-0"
2'-0"
2'-0"
B/ EXISTING CEILING • EL. 11'-0"
11'-0
"
T/ EXISTING FLOOR SLAB • EL. 0'-0"
B/ EXISTING CEILING • EL. 11'-0"
11'-0
"
T/ EXISTING FLOOR SLAB • EL. 0'-0"
B/ EXISTING CEILING • EL. 11'-0"
11'-0
"
T/ EXISTING FLOOR SLAB • EL. 0'-0"
2'-0"
2'-0"
2'-0"
10"11'-1"10"
1
K-2338-8VITREOUS CHINALAVATORYBANCROFT K-2338-8VITREOUS CHINALAVATORYBANCROFT
Project:
Architect Contact Information & Seal:
STOA STUDIOSArchitect
52 Riley Rd Ste 374Celebration, FL 34747(407) [email protected] Lic. #RA014339
Sheet:
Drawing:
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
Issue:
Ten
ant Im
prov
emen
t
© 2
017
by St
oa St
udio
s, al
l righ
ts re
serv
ed. A
ll dra
win
gs, il
lustr
atio
ns, id
eas,
and
othe
r info
rmat
ion
cont
aine
d on
this
shee
t are
the
prop
erty
of S
toa
Stud
ios a
nd m
ay n
ot b
e re
prod
uced
eith
er w
holly
or in
par
t in
any
man
ner w
ithou
t the
exp
ress
writ
ten
cons
ent o
f Sto
a St
udio
s.
Engineer Contact Information & Seal:
Gov
erne
r's Sq
uare
Mal
l • S
uite
#10
70 •
Tal
laha
ssee
, Flo
rida
Architect:
S T O AStudios
TECT
E
AR
C
HIU
TUD
ISS
TO
AS
O
R
REVIEW SET 21 JUL 2017
EPG ENGINEERINGEngineer
1325 S. Bumby AveOrlando, FL 32806(407) [email protected] Lic. #PE43599FL Lic. #PE72998
REVIEW SET 25 JUL 2017PERMIT SET 14 AUG 2017
SCALE: 1/4" = 1'-0"
A101
PLAN • DEMOLITION
PRE-DEMOLITION
1. GC and demolition subcontractor shall be responsible for verification of allexisting field conditions so as to become familiarwith the demolition and/orremoval work which may be required to produce the end results intended inthe construction documents. Verification shall be conducted prior tocommencement of any demolition work. Report any discrepancy (fromconditions and dimensions indicated) on these drawings to the Architect priorto commencement of work.
2. GC shall verify working hours with mall management when heavy demolitionis required.
3. GC shall be responsible for obtaining all required permits and pay all fees aspart of the work required for this project.
4. Prior to commencement of demolition work, GC shall coordinate the removalof any and all plumbing, electrical, mechanical, and/or architectural items,including wall partitions, with the corresponding subcontractor.
5. All finishes, materials, systems, etc. which are to remain shall be restored to'like new' condition.
DEMOLITION DEBRIS
6. Remove all debris to dumpster area as designated by the Landlord.Demolition subcontractor shall provide the dumpster unless otherwiseindicated.
7. Removal of construction debris is the responsibility of the demolitionsubcontractor.
8. Demolition subcontractor shall provide removal & insurance of the debris box.9. Demolish and remove from the premises in a manner acceptable to all
jurisdictional agencies, the Landlord, and the GC.10. The site shall be cleared of all demolished components & debris at least once
per day or more often if required to maintain safe working conditions. GCshall verify approved methods & locations for removal with the mallmanagement.
GENERAL
11. The renovation work described in the construction documents anticipates thedemolition of existing construction in part or in its entirety and the removal,relocation, and re-powering of certain construction materials andequipment.
12. Care shall be taken to not remove or damage any work which may affectthe use or operation of any other premises or tenant. Any such damage orremoval shall be immediately repaired or replaced at the sole cost of thesubcontractor.
13. All existing areas scheduled to remain that are damaged during demolitionshall be patched, repaired, and finished as required to match adjacentconstruction. Any such damage or removal shall be immediately repaired orreplaced at the sole cost of the subcontractor.
14. Electrical fixtures, outlets, junction boxes, conduit, piping, panels, transformers,etc., are to be disconnected and/or removed as applicable to the new floorplan as noted in the electrical drawings.
15. All abandoned items (equipment, wiring, plumbing, blocking, etc.) shall becompletely removed from the space.
16. GC shall provide temporary bracing, shoring, and supports as required forexisting structural systems to prevent damage during construction.
17. Sprinkler subcontractor shall relocate and/or provide new sprinkler heads asrequired and so as not to interfere with lighting fixtures, HVAC, grilles, etc. Allwork shall conform to local and NFPA codes. Center sprinkler heads in ceilingtile where applicable. Notify mall management prior to shutting off anyvalves.
WALL FIXTURE REMOVALRemove all existing fixtures, slatwall, and any other wall displayaccessories, leaving only the gypsum board wall cladding; patch& repair gypsum board as necessary, and prepare surface toreceive new fixtures
02
03
04
01
NOT USED
FLOOR & CEILING PLAN KEYNOTESDEMOLITION PLAN GENERAL NOTES
FLOOR PREPARATIONExisting floor is unfinished concrete, with some evidence of a priorfinish floor surface being installed over it; remove all residue fromprior flooring and remove all related components including wallbase, adhesive residue, etc.; fully prepare floor substrates for newfinish flooring per Finish Schedule
05
06
07
NOT USED
NOT USED
08
FLOOR RECEPTACLE LOCATIONRelocate existing floor power and communications receptaclesto new cashier location per E sheets
EXIT SIGNAGE / EMERGENCY LIGHTING RELOCATIONRelocate existing exit signage and emergency lighting asindicated
ft
PLAN • DEMOLITION • FLOOR
8421
Scale: 1/4" = 1'-0"03A101
DEMISING WALL
ft
PLAN • EXISTING/PROPOSED
8421
Scale: 1/4" = 1'-0"04A101
L A N
D L
O R
D ' S
S E
R V
I C E
C O
R R
I D O
R
M A
L L
C O
R R
I D O
R
101
SALES FLOOR
102
STOCKROOM
103
RESTROOM
NOTE
No ceiling modifications are proposed, this plan is included for general reference only.
NOTE
Verify dimensions of existing conditions in field. If substantive discrepancies are discovered betweenactual existing conditions and what is shown in the drawings, notify Architect immediately.
DEMISING WALL
DEMISING WALL / ADJACENT TENANT
DEM
ISING
WAL
L
L A N
D L
O R
D ' S
S E
R V
I C E
C O
R R
I D O
R
M A
L L
C O
R R
I D O
R
101
SALES FLOOR
102
STOCKROOM
103
RESTROOM
DEMISING WALL / ADJACENT TENANTDE
MISI
NG W
ALL
M A L L C O R R I D O R
M A L L C O R R I D O R
DEMISING WALL
DEMISING WALL
M A L L C O R R I D O R
M A L L C O R R I D O R
ft
PLAN • PROPOSED • FLOOR
8421
Scale: 1/4" = 1'-0"01A101
DEMISING WALL
101
SALES FLOOR
102
STOCKROOM
103
RESTROOM
01
DEMISING WALL
DEMISING WALL / ADJACENT TENANT
DEM
ISING
WAL
L
M A L L C O R R I D O R
M A L L C O R R I D O R
0101 01 01
01
01
01 01
02
NOT USED
GENERAL
1. Dimensions to new construction are from to rough framing U.O.N.2. GC is responsible to maintain the structural, architectural, and fire rated
integrity of the project area and other affected areas throughout theduration of the project. All work, materials, and equipment provided byGC shall be guaranteed for a minimum period of one year from date offinal acceptance; GC shall provide owner with all equipment manuals,warranties, and operating instructions for GC provided equipment uponfinal acceptance
3. If conflicting information is discovered within the architectural drawingsand/or specifications, the better quality and/or greater quantity of workand/or materials shall be assumed correct and submitted to Architect forclarification
4. All interior finish and trim materials shall meet applicable coderequirements for flame spread ratings
MILLWORK
1. All millwork depicted herein shall comply with standards for custom gradeas specified in the current edition of the Architectural Woodworker InstituteStandards.
2. All architectural woodwork shall be guaranteed to be of good materialand workmanship and free from defects that render it unserviceable forthe use for which it is intended for a period of one (1) year after approvedfinal installation.
3. All architectural millwork shall be factory finished with field work limited totouch-up only
4. All architectural woodwork occurring on vertical surfaces shall meetstandards for Class A(1) requirements
5. All hardware shall be stainless steel or brushed nickel
PROPOSED PLAN GENERAL NOTES
13
09 NOT USED
08
10 NOT USED
11 WALL ACCENT GRAPHIC11'-1"W x 9'-6"H 'Beya Beya' graphic adhered directly to wall asindicated on plan; graphic extends from top of base board tounderside of floating soffit above; contact Owner for actualdigital file for all graphics
12 NOT USED
1'-0" 6'-0" 10" 7'-0" 10" 11'-1" 2'-6"2'-6" 10" 8'-0" 1'-0"
1'-0"
11'-6
"1'-
2"4'-
81 2"
10"
3'-9"
3'-0"
17'-0"
11"
1'-0"4"9'-0"8"9'-0"
2'-6"
10" 5'-5" 10"
WF08-108 WF08-108
WF08-84WF08-72 WF08-96
WF0
8-13
8
WALL GRAPHIC SHELF
SHEL
F
FRAM
E
FRAME
07
11
14
14
13
13
MIRROR
MIRRORSLATS
SLATS
CASHWRAP
14 WALL SHELVING30"W x12"D x 2"H wall shelving, cantilevered wall-mount style; seeFixture Schedule on A102 for more information; see A701 forelevations and vertical spacing information
EXISTING STOREFRONT GRAPHIC DISPLAY BOXESPreserve and protect existing graphic display boxes throughoutconstruction; replace existing graphics with new graphicsprovided by Owner
M A
L L
C O
R R
I D O
R
15 NOT USED
1