2
Selection Table Model Speed Amps KW Quantity JVEC-LP OPTIONAL MAX SPEED 2.9 1.7 380V – 480V 3Ph PRE-SET MAX SPEED 0.8 0.4 Intergrated Smoke Detector Model Description Y/N JV-SMOKEKIT Smoke Detector Kit Select Control Mode 1650 38th St., Suite 201W | Boulder, CO 80301 | (855) 538-8368 | [email protected] | JetVentFans.com Installed View Page 1 of 2 * Additional Control Options are not included in base price. Typical Specifications The high-velocity jet induction fans shall be of the JetVent Fans JVEC Series by ZOO Fans and shall be the model numbers shown on the schedule/drawings. Backward-curved centrif- ugal impellers, made from aluminum, shall be driven by an EC external rotor motor with integrat- ed EC-Controller and integral thermal overload protection. Fan motors must be configurable to accept direct connection of optional CO, NO2, and temperature sensors, as well as integrated smoke detectors. The housing shall incorporate aerodynamically designed internal flow elements, shall be constructed of galvanized steel with a light gray powder-coated finish, and incorporate mounting brackets. Features > An energy-efficient ventilation system that dynamically adjusts the ventilation rate according to the CO or NO2 pollutant levels, temperature, or smoke in the space > JetVent’s unique digital communication system costs less to install and is simple to commission > Ultra-reliable Ziehl-Abegg ® motor with active protection for thermal overload, locked/blocked rotor, and over/under voltage > EC motor technology eliminates the need for external VFDs, provides current overload protection, and soft start > Highly-efficient, aerodynamically designed internal flow elements > Compact, low-profile fan designed for applications with low ceiling heights > Optional sensors and detectors require no additional power supply PROJECT SUBMITTAL JVEC-LP Low Profile JETVENT ® FANS EC-SERIES | GARAGE VENTILATION (38-5/8 in) (35-5/8 in) (23-13/16 in) (26-9/16 in) (2-3/4 in) (68-3/4 in) (12-3/4 in) Side View Bottom View Model Description Select Analog Control Configuration: JVEC-LP.ALG Analog Control BAS Control Configurations: JVEC-LP.DIG Modbus Enabled Control JVEC-LP.AUTO Automatic Control with Sensors Additional Digital/Automatic Control Options:* Quantity BAS-CC2 Control Center 2.0 BAS-CC2-EXP Control Center 2.0 Expansion Board BAS-CC2-BN Control Center 2.0 BACnet Interface Card SEN-CO CO Gas Sensor SEN-NO2 NO2 Gas Sensor

PROJECT SUBMITTAL JVEC-LP Low Profile€¦ · PROJECT SUBMITTAL JVEC-LP Low Profile JETVENT® FANS EC-SERIES | GARAGE VENTILATION Project Job Name: Job Address: City: Architect: Engineer:

  • Upload
    others

  • View
    5

  • Download
    0

Embed Size (px)

Citation preview

Page 1: PROJECT SUBMITTAL JVEC-LP Low Profile€¦ · PROJECT SUBMITTAL JVEC-LP Low Profile JETVENT® FANS EC-SERIES | GARAGE VENTILATION Project Job Name: Job Address: City: Architect: Engineer:

Selection Table Model Speed Amps KW QuantityJVEC-LP OPTIONAL MAX SPEED 2.9 1.7 380V – 480V 3Ph PRE-SET MAX SPEED 0.8 0.4

Intergrated Smoke DetectorModel Description Y/NJV-SMOKEKIT Smoke Detector Kit

Select Control Mode

1650 38th St., Suite 201W | Boulder, CO 80301 | (855) 538-8368 | [email protected] | JetVentFans.com

Installed View

Page 1 of 2 *Additional Control Options are not included in base price.

Typical SpecificationsThe high-velocity jet induction fans shall be of the JetVent Fans JVEC Series by ZOO Fans™ and shall be the model numbers shown onthe schedule/drawings. Backward-curved centrif-ugal impellers, made from aluminum, shall be driven by an EC external rotor motor with integrat-ed EC-Controller and integral thermal overload protection. Fan motors must be configurable to accept direct connection of optional CO, NO2, and temperature sensors, as well as integrated smoke detectors. The housing shall incorporate aerodynamically designed internal flow elements, shall be constructed of galvanized steel with a light gray powder-coated finish, and incorporate mounting brackets.

Features> An energy-efficient ventilation system that dynamically adjusts the ventilation rate according to the CO or NO2 pollutant levels, temperature, or smoke in the space> JetVent’s unique digital communication system costs less to install and is simple to commission > Ultra-reliable Ziehl-Abegg® motor with active protection for thermal overload, locked/blocked rotor, and over/under voltage> EC motor technology eliminates the need for external VFDs, provides current overload protection, and soft start> Highly-efficient, aerodynamically designed internal flow elements> Compact, low-profile fan designed for applications with low ceiling heights > Optional sensors and detectors require no additional power supply

PROJECT SUBMITTAL

JVEC-LP Low ProfileJETVENT® FANS EC-SERIES | GARAGE VENTILATION

(38-5/8 in) (35-5/8 in)

(23-13/16 in)

(26-9/16 in)

(2-3/4 in)

(68-3/4 in)

(12-3/4 in)

Side View

Bottom View

Model Description Select Analog Control Configuration:JVEC-LP.ALG Analog ControlBAS Control Configurations:JVEC-LP.DIG Modbus Enabled Control

JVEC-LP.AUTO Automatic Control with Sensors Additional Digital/Automatic Control Options:* Quantity BAS-CC2 Control Center 2.0

BAS-CC2-EXP Control Center 2.0 Expansion Board

BAS-CC2-BN Control Center 2.0 BACnet Interface Card

SEN-CO CO Gas Sensor

SEN-NO2 NO2 Gas Sensor

Page 2: PROJECT SUBMITTAL JVEC-LP Low Profile€¦ · PROJECT SUBMITTAL JVEC-LP Low Profile JETVENT® FANS EC-SERIES | GARAGE VENTILATION Project Job Name: Job Address: City: Architect: Engineer:

PROJECT SUBMITTAL

JVEC-LP Low ProfileJETVENT® FANS EC-SERIES | GARAGE VENTILATION

Project Job Name:

Job Address:

City:

Architect:

Engineer:

Contractor:

State: ZIP:

1650 38th St., Suite 201W | Boulder, CO 80301 | (855) 538-8368 | [email protected] | JetVentFans.comPage 2 of 2

Comments

Technical Specifications

Date:

Enclosed or semi-enclosed spaces that contain harmful vehicle exhaust pollutants, such as commercial and residential garages, auto service and repair shops, loading bays, drive through facilities, and indoor go-kart tracks. JetVent Fans can also increase cross-flow ventilation in open parking garages.

Typical Applications

Sound Power LevelsLw re 1pW, Hz 63 125 250 500 1k 2k 4k 8kHigh Speed, dB 82 85 91 83 84 82 80 74 Advised Speed, dB 74 82 73 71 71 73 65 56

Optional Pre-Set Max Speed Max Speed

Garage-Installed Sound* 76 65dB(A) @ 8m

Free-FieldSound** 69 57dB(A) @ 3m

* Installed sounds levels measured 8m from multiple fans operating ** Free-field sound measured 3m from fan with multiple fans operating

Sound Level Calculations

Optional Pre-Set Max Speed Max Speed

Newtons 46.8 18.9

CFM 3178 1971RPM 1800 1140

Performance

Certifications

ETL Listed, Conforms to UL Standard 507Sound measurements in accordancewith ISO 13347

Type

Drive

Bearings

Protection

Ziehl-Abegg ECblue®

Electrically Commutated (EC) Direct DriveSealed, Lifetime LubricatedActive protection for thermaloverload, locked/blockedrotor, and over/under voltage

Motor

TypeDesign

Safety

Powder-Coated Galvanized SteelLow-Profile, with InternalAerodynamic Flow ComponentsIntake Safety Grill

Housing

Analog

DigitalAutomatic

Integrated Control Modes 0-10VDC4-20mAPWMMODBUS Integrated automatic controlwith attached sensors

©2018 ZOO FANS INC. ALL RIGHTS RESERVED 013118