Upload
kristin-blair
View
213
Download
0
Tags:
Embed Size (px)
Citation preview
Intelligent Data Sets Project
• 3 year project ending December 31 2008 with a total budget of 2.7 mill USD– Funded by Research Council of Norway
(NRC) and participants
• Participants– Operator– Solution Providers– Consultants– Associations
• Collaborating associations and projects– Accelerating Deployment of ISO 15926
(ADI) and FIATECH (US initiatives)
Intelligent Data Sets Project Objective• The objective of the project is to
– Develop a methodology for mapping existing proprietary data representations to/from an ISO 15926 representation to support data exchange and integration using “Intelligent Data Sets”
– This provides data separated from presentations, which again allows assembly of data in new formats targeted at new work processes
– To study how this support new collaborative work processes within and between organizations is a research topic at the UiS.
One neutral, extendable description, supporting multiple views across phases and applications
Many different, view dependant descriptions- business- company- phase (lifecycle)- application (DS/2D/3D)- etc
DatasheetTransmitter, Pressure, Electric
Document Number : 28-1A-KOG-I54-27500-0012 Revision : 1Plant/Platform : Test Installation 2 Process Datash. No. : N/ATag number : PT -42-0304 System : N/ASerialNo : N/A Range From : 0SetPoint Low : 10 barG Range To : 110SetPoint Hight : 71 barG Range Unit : barGP & ID : 28-1A-KOG-C78-00275-0002 Area : N/ALine/Equipment no. : XX-42-0002 PO: : TI2-M022-ME-01Service description : SCALE INHIBITOR. PUMP OUTLET
Unique no. TEK-00018117Manufacturer EMERSON PROCESS MANAGEMENTType 3051CGManuf. Partno. 3051CG-5-A-2-2-A-1-K-B4-I1-L4-M6-Q4Class Transmitter, Pressure, Electric
Area General
Explosion protection : EEx ia Description : GaugeGas-group : IIC Description : Smart, hart protocol
Temperature class : T5 Supply : 10.5 - 55 V DC
Approval authority : BASEEFA Mounting : Coplanar flange bracket for
Certificate : BAS 97ATEX1089X pipe or panel
IP-Class : IP66
ATEX group : II Material
ATEX category : 1 Body material : Stainless steel
ATEX explosive atmosphere : G Filling fluid : Silicone oil
Ambient temperature : -40 - 85 °C Seal material : Glass filled TFE
Process connection material : Stainless steel
Dimensions and Weight Non process cover material : 316
Weight : 4.7 kg Flange bolt material : 316 AUSTENITIC
Drain/vent material : Stainless steel
Function Diaphragm material low pressure : 316L
Range : 0 - 13800 kPa connection
Span limit minimum, Pressure : 138 kPa Diaphragm material high pressure: 316L
Span limit maximum, Pressure : 13800 kPa connection
Alternative Range : 0 - 138 bar Bracket material : Stainless steel
Alternative span limit minimum, : 1.38 bar Bracket bolt material : Stainless steel
Pressure Adapter bolt material : 316 AUSTENITIC
Alternative span limit maximum, : 138 bar
Pressure Process Connection
Output signal : 4 - 20 mA Connection design : NPT
Accuracy : +/- 0.075 % Size : 1/4"
Display type : LCD Thread pitch : 18 thr/in
Static working pressure : 3626 psi
Supply Connection
Supply connection design : Metric threaded
Supply connection size : 20 mm
Thread pitch supply : 1.5 mm/thr
Comment
Accuracy for span greater than 10:1 of URL. Power consumption 18-36
mW. Load limitation: 587 Ohm. Static pressure value valid within transmitter temperature
spec. Output: Digital signal based on hart protocol. Coplanar flange Intrinsic Safety and
Dust approval. Calibration data sheet (5 points calibration at 0%, 25%, 50%, 75%, and 100%
of range)
1 09.11.2006 14:44 Generated by P.M.
Rev. Date Issue/description Prepared Cheked Disc. Appr. Client. Appr. Page 1 of 1
Examples Of Inconsistent Representations Datasheet
Transmitter, Pressure, Electric
Document Number : 28-1A-KOG-I54-27500-0012 Revision : 1Plant/Platform : Test Installation 2 Process Datash. No. : N/ATag number : PT -42-0304 System : N/ASerialNo : N/A Range From : 0SetPoint Low : 10 barG Range To : 110SetPoint Hight : 71 barG Range Unit : barGP & ID : 28-1A-KOG-C78-00275-0002 Area : N/ALine/Equipment no. : XX-42-0002 PO: : TI2-M022-ME-01Service description : SCALE INHIBITOR. PUMP OUTLET
Unique no. TEK-00018117Manufacturer EMERSON PROCESS MANAGEMENTType 3051CGManuf. Partno. 3051CG-5-A-2-2-A-1-K-B4-I1-L4-M6-Q4Class Transmitter, Pressure, Electric
Area General
Explosion protection : EEx ia Description : GaugeGas-group : IIC Description : Smart, hart protocol
Temperature class : T5 Supply : 10.5 - 55 V DC
Approval authority : BASEEFA Mounting : Coplanar flange bracket for
Certificate : BAS 97ATEX1089X pipe or panel
IP-Class : IP66
ATEX group : II Material
ATEX category : 1 Body material : Stainless steel
ATEX explosive atmosphere : G Filling fluid : Silicone oil
Ambient temperature : -40 - 85 °C Seal material : Glass filled TFE
Process connection material : Stainless steel
Dimensions and Weight Non process cover material : 316
Weight : 4.7 kg Flange bolt material : 316 AUSTENITIC
Drain/vent material : Stainless steel
Function Diaphragm material low pressure : 316L
Range : 0 - 13800 kPa connection
Span limit minimum, Pressure : 138 kPa Diaphragm material high pressure: 316L
Span limit maximum, Pressure : 13800 kPa connection
Alternative Range : 0 - 138 bar Bracket material : Stainless steel
Alternative span limit minimum, : 1.38 bar Bracket bolt material : Stainless steel
Pressure Adapter bolt material : 316 AUSTENITIC
Alternative span limit maximum, : 138 bar
Pressure Process Connection
Output signal : 4 - 20 mA Connection design : NPT
Accuracy : +/- 0.075 % Size : 1/4"
Display type : LCD Thread pitch : 18 thr/in
Static working pressure : 3626 psi
Supply Connection
Supply connection design : Metric threaded
Supply connection size : 20 mm
Thread pitch supply : 1.5 mm/thr
Comment
Accuracy for span greater than 10:1 of URL. Power consumption 18-36
mW. Load limitation: 587 Ohm. Static pressure value valid within transmitter temperature
spec. Output: Digital signal based on hart protocol. Coplanar flange Intrinsic Safety and
Dust approval. Calibration data sheet (5 points calibration at 0%, 25%, 50%, 75%, and 100%
of range)
1 09.11.2006 14:44 Generated by P.M.
Rev. Date Issue/description Prepared Cheked Disc. Appr. Client. Appr. Page 1 of 1
NORSOK INSTRUMENT DATASHEET P01
PRESSURE / DIFF. PRESSURE INSTRUMENT ELECTRIC
Tag number : Scale Range :
Service description : Set/Alarm Point :
P&ID : Area :
Line/equipment no. : P. O. Number :
1 GENERAL 5 TRANSMITTER1.01 Type : 5.01 Indicator :
1.02 Manufacturer : 5.02 Output signal :
1.03 Manufacturer model no : 5.03 Communication :
5.04 Supply voltage :
1.04 Operating Temp. Limits : 5.05 Consumption :
1.05 Mounting : 5.06 Load limitation :
1.06 Weight : 5.07 Other :
1.07 Other :
6 SWITCH2 INSTRUMENT CHARACTERISTICS 6.01 Reset; automatic or manual :
2.01 Calibrated input range : 6.02 Deadband or differential :
2.02 Characteristic : 6.03 Alarm at increase/decrease :
2.03 Accuracy : 6.04 Contact configuration :
2.04 Repeatability : 6.05 Contact material :
2.05 Lower / upper range limits : 6.06 Contact rating :
2.06 Min / max span : 6.07 Contact action on alarm :
2.07 Zero adjustment : 6.08 Other :
2.08 Overpressure protect. to :
2.09 Max static pressure :
2.10 Other : 7 CHEMICAL SEAL7.01 Type :
7.02 Material, upper/lower part :
3 ELEMENT / SENSOR 7.03 Material, bolts / nuts :
3.01 Type : 7.04 Material, diaphragm :
3.02 Material, element (sensor) : 7.05 Fill fluid :
3.03 Material, socket (inlet port) : 7.06 Capillary length/diameter :
3.04 Material, sensor bolts/nuts : 7.07 Material, capillary/armour :
3.05 Process conn. size/type : 7.08 Process conn. size/type :
3.06 Sour service spec. : 7.09 Other :
3.07 Other :
8 ACCESSORIES4 HOUSING 8.01 Mounting bracket :
4.01 Dimension : 8.02 Material, mounting bracket :
4.02 Material : 8.03 Overpr. protection valve :
4.03 Cable connection : 8.04 Material, overpr. prot. valve :
4.04 Cable entry : 8.05 Pulsation damper :
4.05 Enclosure protection : 8.06 Material, pulsation damper :
4.06 Ex. classification : 8.07 Other :
4.07 Protective coating :
4.08 Other :
9 NOTES
Rev Date Issue/description Prepared Checked Approved Datasheet no. Page
Daily Challenges For Data Sheet Mapping
• In order to resolve this, a neutral, system independent representation that can map to any proprietary representation is required.
• Need to recognise which representation is used by which proprietary representation
SHARECAT M45, M46, M47NORSOK B37
14 Conn. Size/Type Proc. : 1/4"-18 NPT (F)
Connection design. : NPTSize : 1/4”Thread pitch : 18 thr/in
ANSI/ASME B1.20.1 1/4 - 18 NPT-F
Representation 1, Context 1 Representation 2, Context 2
Context Of Codes IDatasheet
Transmitter, Pressure, Electric
Document Number : 28-1A-KOG-I54-27500-0012 Revision : 1Plant/Platform : Test Installation 2 Process Datash. No. : N/ATag number : PT -42-0304 System : N/ASerialNo : N/A Range From : 0SetPoint Low : 10 barG Range To : 110SetPoint Hight : 71 barG Range Unit : barGP & ID : 28-1A-KOG-C78-00275-0002 Area : N/ALine/Equipment no. : XX-42-0002 PO: : TI2-M022-ME-01Service description : SCALE INHIBITOR. PUMP OUTLET
Unique no. TEK-00018117Manufacturer EMERSON PROCESS MANAGEMENTType 3051CGManuf. Partno. 3051CG-5-A-2-2-A-1-K-B4-I1-L4-M6-Q4Class Transmitter, Pressure, Electric
Area General
Explosion protection : EEx ia Description : GaugeGas-group : IIC Description : Smart, hart protocol
Temperature class : T5 Supply : 10.5 - 55 V DC
Approval authority : BASEEFA Mounting : Coplanar flange bracket for
Certificate : BAS 97ATEX1089X pipe or panel
IP-Class : IP66
ATEX group : II Material
ATEX category : 1 Body material : Stainless steel
ATEX explosive atmosphere : G Filling fluid : Silicone oil
Ambient temperature : -40 - 85 °C Seal material : Glass filled TFE
Process connection material : Stainless steel
Dimensions and Weight Non process cover material : 316
Weight : 4.7 kg Flange bolt material : 316 AUSTENITIC
Drain/vent material : Stainless steel
Function Diaphragm material low pressure : 316L
Range : 0 - 13800 kPa connection
Span limit minimum, Pressure : 138 kPa Diaphragm material high pressure: 316L
Span limit maximum, Pressure : 13800 kPa connection
Alternative Range : 0 - 138 bar Bracket material : Stainless steel
Alternative span limit minimum, : 1.38 bar Bracket bolt material : Stainless steel
Pressure Adapter bolt material : 316 AUSTENITIC
Alternative span limit maximum, : 138 bar
Pressure Process Connection
Output signal : 4 - 20 mA Connection design : NPT
Accuracy : +/- 0.075 % Size : 1/4"
Display type : LCD Thread pitch : 18 thr/in
Static working pressure : 3626 psi
Supply Connection
Supply connection design : Metric threaded
Supply connection size : 20 mm
Thread pitch supply : 1.5 mm/thr
Comment
Accuracy for span greater than 10:1 of URL. Power consumption 18-36
mW. Load limitation: 587 Ohm. Static pressure value valid within transmitter temperature
spec. Output: Digital signal based on hart protocol. Coplanar flange Intrinsic Safety and
Dust approval. Calibration data sheet (5 points calibration at 0%, 25%, 50%, 75%, and 100%
of range)
1 09.11.2006 14:44 Generated by P.M.
Rev. Date Issue/description Prepared Cheked Disc. Appr. Client. Appr. Page 1 of 1
NORSOK INSTRUMENT DATASHEET P01
PRESSURE / DIFF. PRESSURE INSTRUMENT ELECTRIC
Tag number : Scale Range :
Service description : Set/Alarm Point :
P&ID : Area :
Line/equipment no. : P. O. Number :
1 GENERAL 5 TRANSMITTER1.01 Type : 5.01 Indicator :
1.02 Manufacturer : 5.02 Output signal :
1.03 Manufacturer model no : 5.03 Communication :
5.04 Supply voltage :
1.04 Operating Temp. Limits : 5.05 Consumption :
1.05 Mounting : 5.06 Load limitation :
1.06 Weight : 5.07 Other :
1.07 Other :
6 SWITCH2 INSTRUMENT CHARACTERISTICS 6.01 Reset; automatic or manual :
2.01 Calibrated input range : 6.02 Deadband or differential :
2.02 Characteristic : 6.03 Alarm at increase/decrease :
2.03 Accuracy : 6.04 Contact configuration :
2.04 Repeatability : 6.05 Contact material :
2.05 Lower / upper range limits : 6.06 Contact rating :
2.06 Min / max span : 6.07 Contact action on alarm :
2.07 Zero adjustment : 6.08 Other :
2.08 Overpressure protect. to :
2.09 Max static pressure :
2.10 Other : 7 CHEMICAL SEAL7.01 Type :
7.02 Material, upper/lower part :
3 ELEMENT / SENSOR 7.03 Material, bolts / nuts :
3.01 Type : 7.04 Material, diaphragm :
3.02 Material, element (sensor) : 7.05 Fill fluid :
3.03 Material, socket (inlet port) : 7.06 Capillary length/diameter :
3.04 Material, sensor bolts/nuts : 7.07 Material, capillary/armour :
3.05 Process conn. size/type : 7.08 Process conn. size/type :
3.06 Sour service spec. : 7.09 Other :
3.07 Other :
8 ACCESSORIES4 HOUSING 8.01 Mounting bracket :
4.01 Dimension : 8.02 Material, mounting bracket :
4.02 Material : 8.03 Overpr. protection valve :
4.03 Cable connection : 8.04 Material, overpr. prot. valve :
4.04 Cable entry : 8.05 Pulsation damper :
4.05 Enclosure protection : 8.06 Material, pulsation damper :
4.06 Ex. classification : 8.07 Other :
4.07 Protective coating :
4.08 Other :
9 NOTES
Rev Date Issue/description Prepared Checked Approved Datasheet no. Page
Context Of Codes II
T5: www.informativos.telecinco.es
t5.no-thobben på nett
Sony tilbakekaller Cyber-shot DSC-T5
Volvo T5
IP66: IP66 APPARATUS IEC 60529
EEx ia: EX IA APPARATUS IEC 60079-11
Area
Explosion protection : EEx ia
Gas-group : IIC
Temperature class : T5
Approval authority : BASEEFA
Certificate : BAS 97ATEX1089X
IP-Class : IP66
ATEX group : II
ATEX category : 1
ATEX explosive atmosphere : G
Ambient temperature : -40 - 85 °C
IIC here: GROUP IIC APPARATUS IEC 60079-0
T5 here: T5 APPARATUS IEC 60079-0
IIC: International Institute for Conservation of Historic and Artistic Works
Local Name
Class Name
Local Name
Class Name
IDS
• Intelligent Data Sets• Support mapping and exchange between proprietary data sheet
formats using 15926 templates and RDL• RDL/ontology development for Oil & Gas• Template development
– Generic basic templates– Assembly into molecular templates– Represent complex data sheets using templates
• Template application– Implement template definitions as instantiation scripts in (e.g.) SWRL– Rules generate rich 15926 structures for standardized storage– Common representation of data supports exchange– Validation and quality checks on data
ADI
• Accelerating Deployment of ISO 15926 (ADI)– Bechtel– Bentley– Fluor Daniel
• The ADI project defines 15926 Part 7: Templates– Implementation methods for the integration of distributed systems– Develops SW for the RDS/WIP “inbox”
• POSC Caesar provides– Methodology for Part 7 template specification, using First-order
logic– Initial set of template definitions– Validation of templates using automated reasoning
• 15926 Part 2 in OWL format• Longhand template definitions expressed as SWRL rules
– Hosting ADI software to access POSC Caesar Reference Data System (RDS)
• Aramco Services Company• Atomic Energy Canada Ltd• AVEVA• Barton Consulting• Bechtel Corporation• Bentley Systems• COADE• ConocoPhillips• Consolidated Contractors Company• DNV• Dow Chemical• DuPont• Fluor Corporation• Georgia Institute of Technology
• Hatch• Intergraph• KBR• National Institute of
Standards & Technology (NIST)
• Noumenon Consulting • NRX Global • OntoConsult• POSC Caesar Association • Procter & Gamble • Software Innovation• USPI• VTT
ADI Sponsors
• Need a neutral representation, independent of– Application– System– Lifecycle stage
• An integration model– Conceptual model
• Needed to be concerned with “what things are” as opposed to their representation– Need for semantics
• How things are related– Need for a rich ontology
Lessons Learned From Developing ISO 15926 (I)
• The obvious choice for us was set theory and first order logic (FOL)– All specifications used in the industry are by nature about class membership– Developing a specification is adding constraints, i.e. defining subclasses
• Later we ran into the problem “What is information about a class member as opposed to information about the class itself?”
• Led to the identification of the need for Second Order Classes– The classes had to be dealt with as object– We have later discovered that we also have Third Order Classes– Will probably later need even higher level classes
• Note that this is observations discovered from industrial needs.• We were introduced to OWL in 2003, and decided to test this to see if
this was the way forward• We ran into lengthy discussions of OWL Full vs. DL
– The current state of development indicates both, Full to support lifecycle data, DL for reasoning.
• POSC Caesar, which is a Norwegian based industry association, and one of the organisations behind ISO 15926 has become W3C member, and is participating in the establishment of a W3C O&G Incubator Group.
Lessons Learned From Developing ISO 15926 (II)
• Most systems used in the industry are “proprietary” systems and will probably be in use for a long time to come
• They all use their internal representations, and will continue to do so• Systems can be interfaced, but at a considerable cost. Resource
restrictions.• They have to be interfaced to new systems whenever project
participants change• If an ontology is not interfaced to existing systems it will only be useful
for new developments, systems etc., not for use with existing systems• Tool support to map between standardised and proprietary
representations. Templates (ISO 15926-7) and IDS tools are means to achieve this
• An ontology will never be completed, a system must be in place to handle extensions
• Capability to handle lifecycle data• Reasoning over data quality• Interfacing the ISO 15926 ontology to existing systems and setting up
a system to handle extensions is what the IDS project is about
Lessons Learned From Developing ISO 15926 (III)
Main Objectives
• The primary objective of the project is to develop:
A demonstrated reliable digital platform for Integrated Operation Generation 2 (IO G2) in the High North
IO G2 pilots within drilling, R&P, O&M in the High North
Decision Support for drilling, R&P, O&M
• IO G2 for the High North shall facilitate operations in remote and hazardous conditions, the use of limited operational personnel and “zero footprint” solutions
Project Architecture – Technical view
Business processes
Dig
ital p
latf
orm
UnmannedDrilling rig
Improvedproduction
Sub-iceoperation
Semantic oil and gas platform and information assurance
Networks, infrastructure and web services
Autonomous and failsafe subsea control systems
Risk management for reliable information & IT
Activity 1
Activity 2
Activity 3
Activity 4
Activity 5 Activity 6 Activity 7
Semantic Oil & Gas Platform
Objectives:• To extend and improve the
content and quality of the ISO 15926 based oil and gas ontology
• To develop a prototype information validation service
Semantic Oil & Gas Platform
Main deliverables:1. Ontology building methodology from the IDS project
adapted to the addressed domains2. Extended and improved Oil & Gas ontology with
Oil & Gas production ontology including relevant parts of PRODML, Daily Production Report and Monthly Production Report
ISO 10303-239 Product Life Cycle Support (PLCS) Operation & Maintenance ontology including relevant parts of
IBM’s RSM, ISA95 and ISA88 and ISO 13375/Mimosa Drilling ontology
3. A prototype information validation service based on semantic web technology, IDS-templates and the oil & gas ontology
Committed Participants and Funding
• Committed to join: StatoilHydro, Norwegian Defence, IBM, DNV, National Oilwell
Varco, Invenia, Computas, Epsis, TietoEnator, FMC, SAS Institute, Kongsberg, PSA Centre of Integrated Operations, IRIS, NTNU, UiO, UiS, POSC Caesar, OLF, Abelia and FSi
Representing a total committed funding of 70 MNOK (RCN 17 MNOK)
• Project will start as described with activity 2,3,4,5 and 7
• Activities 1 and 6 will start as soon as funding is secured
• Start-up 2008-05-01 - Duration 4 years
• Target total budget 90 MNOK