PROLAM® Preferred

H5 Laminated Posts

H3.2 Laminated Beams

Page 2: PROLAM - Amazon Web Services · BEAM SIZES / CODES AND USES STRUCTURAL PL12 Prolam ® GL12 H3.2 KD precambered. Extra high performance beam for high load, high spanning situation

Sustainable Solutions

283 Waiwhero Rd P O Box 413 Motueka New Zealand Phone 03 526 7436 Fax 03 526 7437Email: [email protected]

PROLAM® PREFERRED

Prolam® Preferred Calculator is a stand alone Acrobat file which does not require installation. It has a built in powerful calculation program complete with database and does not need any external files.

It is so simple to use, you wonder why no one thought of it before!!As it is an Acrobat file it can be used on any platform and requires only the free Acrobat Reader. Most computers do have it installed, if not, go to www.adobe.com and download the latest Acrobat Reader and install it on your system. It is best to use version 8 or above.

The Prolam® Preferred Calculator requires virtually no training to use it. Page has a step by step guide to make you absolutely comfortable using the Prolam® Preferred Calculator.

INSTRUCTIONSFill in the date, job description and the description for the page. The date & job description will automatically repeat on each page.Then fill in the boxes after the red text with the span, setback, etc. and select the tick boxes for the appropriate conditions. Press the Calculate Button.The recommended Prolam® products are displayed. Choose one or both by ticking any of the buttons displayed by the products. To alter any of the details, make the changes and press the Calculate button again.The details will stay in the form until you exit the Prolam® Preferred Calculator. When complete print out the Summary, Producer Statement, Design Data and Fixing & Support Details. Each page can be repeated by printing out the result and re-entering new data. When complete, print out the Summary, Producer Statement, Design Data and Fixing & Support Details. If you own Acrobat Standard or Professional, you can save your calculation and continue with it another time by renaming the file to suit, e.g. your job name/number. Acrobat Reader will not allow you to save the file with the form details, however, you can print it out as hard and electronic copies. To print out an electronic copies, go to the print box and select Microsoft XPS Document Writer as your printer. If this is not on your system, you can use Microsoft Image Writer, but this does result in larger & individual files and the print quality is not as good as an XPS file. Other document writers such as Paperport can also be used.Free Microsoft XPS Document Writer & Reader (as a standalone program) can be downloaded from http://www.microsoft.com/downloads/details.aspx?FamilyId=B8DCFFDD-E3A5-44CC-8021-7649FD37FFEE&displaylang=en Download XPSEP XP and Server 2003 32 bit.msi (32 bit) or XPSEP XP and Server 2003 64 bit.msi (64 bit). If not sure select the 32 bit.Installation is fast and simple.

Page 3: PROLAM - Amazon Web Services · BEAM SIZES / CODES AND USES STRUCTURAL PL12 Prolam ® GL12 H3.2 KD precambered. Extra high performance beam for high load, high spanning situation

BEAM SIZES / CODES AND USESSTRUCTURAL

PL12 Prolam® GL12 H3.2 KD precambered. Extra high performance beam for high load, high spanning situation.

PLL Prolam® Lintel/Deck Bearer GL8 H3.2 KD precambered high performance beam using MSG 8, economy beam for high load situations. Will span most garage doors.

88

315

PL12 350

88

290

PL12 300

88

240

PL12 250

88

190

PL12 200

88

315

PLL 350

8829

0

PLL 300

88

240

PLL 250

88

190

PLL 200

88

140

PLL 150

636363

240

29031

5

63

190

63

140

63

90

240

190

140

PLR Prolam® Verandah Rafter GL8 H3.2 KD. Precambered high performance beam using MSG8, economy beam for high load situations. Excellent for above ceiling rafters, and floor joists.

PLR 250PLR 300PLR 350 PLR 200 PLR 150 PLR 100

PLR 250 50 PLR 200 50 PLR 150 50

424242424242

90

PLR 100 50

29031

5

PLR 300 50PLR 350 50

Page 4: PROLAM - Amazon Web Services · BEAM SIZES / CODES AND USES STRUCTURAL PL12 Prolam ® GL12 H3.2 KD precambered. Extra high performance beam for high load, high spanning situation

636363

240

29031

5

63

190

63

140

63

90

PLVR Prolam® Verandah Rafter GL8 H3.2 KD No 2 clears. Precambered high performance beam in a No 2 clear grade for high visual applications.

88

240

PLVL 250

88

290

PLVL 300

88

315

PLVL 350

88

190

PLVL 200

88

140

PLVL 150

PLVR 250PLVR 300PLVR 350 PLVR 200 PLVR 150 PLVR 100

PLVL Prolam® Verandah Lintel GL8 H3.2 KD No 2 clears. Precambered high performance beam in a No 2 clear grade for high visual applications.

BEAM SIZES / CODES AND USESVISUAL NO 2 CLEARS

PLVR 250 50 PLVR 200 50 PLVR 150 50 PLVR 100 50PLVR 300 50PLVR 350 50

PLP Prolam® Posts GL8 H5 KD No 2 clears. Superior laminated posts in a No 2 clears H5 treated for inground use.

180

180

PLP 200

135

135PLP 150

112

112PLP 125

88

88PLP 100

240

190

140

424242424242

90

29031

5

Page 5: PROLAM - Amazon Web Services · BEAM SIZES / CODES AND USES STRUCTURAL PL12 Prolam ® GL12 H3.2 KD precambered. Extra high performance beam for high load, high spanning situation

Sustainable Solutions

283 Waiwhero Rd P O Box 413 Motueka New Zealand Phone 03 526 7436 Fax 03 526 7437Email: [email protected]

The span tables apply only to Prolam® products

DESIGN DATA

The tables herein have been designed according to the following loads:

ROOF

Dead Load Live Load

Lighweight Roof Heavyweight Roof Ceiling 0.25 kPa Uniform

0.25 kPa 0.65 kPa 0.20 kPa 1.0 kN point load

FLOOR

Dead Load Live Load Permanent Load

Particle Board Floor (including ceiling) Domestic Floor G+0.4Q

0.40 kPa 1.50 kPa, 1.80 kN 1.0 kPa

DEFLECTION CRITERIA

Deflection Max long term deflection Span / 450

Criteria Max live load deflection Span / 400

Page 6: PROLAM - Amazon Web Services · BEAM SIZES / CODES AND USES STRUCTURAL PL12 Prolam ® GL12 H3.2 KD precambered. Extra high performance beam for high load, high spanning situation

SUMMARY

283 Waiwhero Rd P O Box 413 Motueka New Zealand Phone 03 526 7436 Fax 03 526 7437Email: [email protected]

Page 7: PROLAM - Amazon Web Services · BEAM SIZES / CODES AND USES STRUCTURAL PL12 Prolam ® GL12 H3.2 KD precambered. Extra high performance beam for high load, high spanning situation

PROLAM®

PROLAM® LINTELS SUPPORTING ROOF AND CEILING ONLY

R R BA

A ≤ ¼ (A + B), R = B + 2A

R

283 Waiwhero Rd P O Box 413 Motueka New Zealand Phone 03 526 7436 Fax 03 526 7437Email: [email protected]

This specification only applies to Prolam Branded Products

PROLAM® PREFERRED

Page 8: PROLAM - Amazon Web Services · BEAM SIZES / CODES AND USES STRUCTURAL PL12 Prolam ® GL12 H3.2 KD precambered. Extra high performance beam for high load, high spanning situation

PROLAM®

PROLAM® RIDGE BEAM SUPPORTING ROOF AND SARKING OR CEILING(RAFTERS AT 1200mm CRS MAX)

R R

283 Waiwhero Rd P O Box 413 Motueka New Zealand Phone 03 526 7436 Fax 03 526 7437Email: [email protected]

This specification only applies to Prolam Branded Products

PROLAM® PREFERRED

Page 9: PROLAM - Amazon Web Services · BEAM SIZES / CODES AND USES STRUCTURAL PL12 Prolam ® GL12 H3.2 KD precambered. Extra high performance beam for high load, high spanning situation

PROLAM®

PROLAM® LINTELS BEAM SUPPORTING ROOF AND LOAD-BEARING WALL(2.4m MAX WALL HEIGHT)

283 Waiwhero Rd P O Box 413 Motueka New Zealand Phone 03 526 7436 Fax 03 526 7437Email: [email protected]

This specification only applies to Prolam Branded Products

R BA

R = B + 2A

R

PROLAM® PREFERRED

Page 10: PROLAM - Amazon Web Services · BEAM SIZES / CODES AND USES STRUCTURAL PL12 Prolam ® GL12 H3.2 KD precambered. Extra high performance beam for high load, high spanning situation

PROLAM®

PROLAM® LINTELS FLOOR AND WALL (2.4m MAX WALL HEIGHT)

283 Waiwhero Rd P O Box 413 Motueka New Zealand Phone 03 526 7436 Fax 03 526 7437Email: [email protected]

This specification only applies to Prolam Branded Products

F = A + B

BAF

PROLAM® PREFERRED

Page 11: PROLAM - Amazon Web Services · BEAM SIZES / CODES AND USES STRUCTURAL PL12 Prolam ® GL12 H3.2 KD precambered. Extra high performance beam for high load, high spanning situation

PROLAM®

PROLAM® LINTEL SUPPORTING GIRDER/SETBACK TRUSSES

283 Waiwhero Rd P O Box 413 Motueka New Zealand Phone 03 526 7436 Fax 03 526 7437Email: [email protected]

This specification only applies to Prolam Branded Products

Setback

Girde

r Tr

uss

Spa

n

Setback or Support Roof Span

Girde

r Tr

uss

Spa

n

PROLAM® PREFERRED

Page 12: PROLAM - Amazon Web Services · BEAM SIZES / CODES AND USES STRUCTURAL PL12 Prolam ® GL12 H3.2 KD precambered. Extra high performance beam for high load, high spanning situation

PROLAM®

PROLAM® LINTEL SUPPORTING ROOF, WALL AND FLOOR JOISTS (2.4m MAX WALL HEIGHT)

283 Waiwhero Rd P O Box 413 Motueka New Zealand Phone 03 526 7436 Fax 03 526 7437Email: [email protected]

This specification only applies to Prolam Branded Products

R

R = B + 2A

R B

F F F

PROLAM® PREFERRED

Page 13: PROLAM - Amazon Web Services · BEAM SIZES / CODES AND USES STRUCTURAL PL12 Prolam ® GL12 H3.2 KD precambered. Extra high performance beam for high load, high spanning situation

PROLAM®

PROLAM® 1.5kPa & 3.0kPa FLOOR BEAM SUPPORTING JOISTS

283 Waiwhero Rd P O Box 413 Motueka New Zealand Phone 03 526 7436 Fax 03 526 7437Email: [email protected]

This specification only applies to Prolam Branded Products

BA

F

F

PROLAM® PREFERRED

Page 14: PROLAM - Amazon Web Services · BEAM SIZES / CODES AND USES STRUCTURAL PL12 Prolam ® GL12 H3.2 KD precambered. Extra high performance beam for high load, high spanning situation

PROLAM®

PROLAM® INTERNAL & VERANDAH RAFTERS

SELECTION CHARTS

283 Waiwhero Rd P O Box 413 Motueka New Zealand Phone 03 526 7436 Fax 03 526 7437Email: [email protected]

This specification only applies to Prolam Branded Products

Prolam® Rafter

Prolam® Lintel

Prolam® Post

Verandah Roof Widthand Rafter Span

Rafter Span

Page 15: PROLAM - Amazon Web Services · BEAM SIZES / CODES AND USES STRUCTURAL PL12 Prolam ® GL12 H3.2 KD precambered. Extra high performance beam for high load, high spanning situation

PROLAM®

PROLAM® EXTERNAL VERANDAH RAFTERS

283 Waiwhero Rd P O Box 413 Motueka New Zealand Phone 03 526 7436 Fax 03 526 7437Email: [email protected]

This specification only applies to Prolam Branded Products

Prolam® Rafter

Prolam® Lintel

Prolam® Post

Verandah Roof Widthand Rafter Span

PROLAM® PREFERRED

Page 16: PROLAM - Amazon Web Services · BEAM SIZES / CODES AND USES STRUCTURAL PL12 Prolam ® GL12 H3.2 KD precambered. Extra high performance beam for high load, high spanning situation

Prolam® Rafter

Prolam® Lintel

Prolam® Post

Verandah Roof Widthand Rafter Span

PROLAM® PREFERRED

Page 17: PROLAM - Amazon Web Services · BEAM SIZES / CODES AND USES STRUCTURAL PL12 Prolam ® GL12 H3.2 KD precambered. Extra high performance beam for high load, high spanning situation

PROLAM® PREFERRED

283 Waiwhero Rd P O Box 413 Motueka New Zealand Phone 03 526 7436 Fax 03 526 7437Email: [email protected]

This specification only applies to Prolam Branded Products

Joist Span 1 Joist Span 2

Average Joist Span = (Joist Span 1 + Joist Span 1) 2

Deck Bearers

Timber Decking

Joist Cantilever refer to next page

Ballustrade (Max 30Kg/m)

Loads: Deck 0.35 kPa Live 2.0 kPaDeflection Limits: Long Term span/400 or 12mm Short Term span/400 or 9mm

Notes: 1. Design to provisions of NZS3603:1993, Timber Structures, and NZS4203:1992 General structural design and design loadings.

2. Timber grade GL8, minimum H3.2 treated - partial wet use.

3. Bearers do not support roof loads. 4. Maximum ballustrade weight 30kg/m. 5. Maximum joist cantilever 400mm. 6. Spans may be increased by 10% for bearers or

joists continuous over 2 or more spans.

Page 18: PROLAM - Amazon Web Services · BEAM SIZES / CODES AND USES STRUCTURAL PL12 Prolam ® GL12 H3.2 KD precambered. Extra high performance beam for high load, high spanning situation

Joist Cantilever tick Cantilever box below

PROLAM®DECK JOISTS & CANTILEVER DECK JOISTS - 2.0kPa (NO CEILING)

PROLAM® PREFERRED

Multiple Joist Span

Timber Decking

Joist

Page 19: PROLAM - Amazon Web Services · BEAM SIZES / CODES AND USES STRUCTURAL PL12 Prolam ® GL12 H3.2 KD precambered. Extra high performance beam for high load, high spanning situation

PROLAM®PROLAM® FLOOR JOISTS

PROLAM® PREFERRED

Multiple Joist Span

Joist

Page 20: PROLAM - Amazon Web Services · BEAM SIZES / CODES AND USES STRUCTURAL PL12 Prolam ® GL12 H3.2 KD precambered. Extra high performance beam for high load, high spanning situation

PROLAM® PREFERRED

Page 21: PROLAM - Amazon Web Services · BEAM SIZES / CODES AND USES STRUCTURAL PL12 Prolam ® GL12 H3.2 KD precambered. Extra high performance beam for high load, high spanning situation

Sustainable Solutions

The span tables apply only to Prolam® products

For Use as Deck Piles GL8 - H5 Treated- Piles supporting timber deck constructed to NZS 3604:1999 clause 7.4)

BRACING UNITS

Height from Ground Level to Bearer Connection (m)

Deck Piles 1.8 2.1 2.4 2.7 3.0 Maximum Height (m) When used as Anchor Pile to

NZS 3604:1991PLP 125112 x 112mm

7.5 5.5 4.0 3.0 2.5

PLP 150135 x 135mm

16 12 9 7 5.5 0.75m

PLP 200180 x 180mm

50 38 29 23 18 1.00m

Footing size when used for bracing (minimum depth into good ground).135 x 135 900 deep x 450 diameter180 x 180 1200 deep x 450 diameterProvide 6 kN connection - Bearer to pile / joist to bearer (as for cantilever piles to NZS 3604:1999)Note: Bracing units have been determined from the lateral load required to give a maximum deflection at the top of the post of H/200.

1 kN = 20 Bu’s E = 6.4 GPa. Linear interpolation of bracing values given is permitted for intermediate heights.

BRACING UNITS

Height from Ground Level to Beam Connection (m)

Verandah Posts 1.8 2.1 2.4 2.7 3.0

PLP 125112 x 112mm

10 7.5 5.5 4.5 3.5

PLP 150135 x 135mm

21 16 12 9.5 7.5

PLP 200180 x 180mm

50 43 37 30 24

Footing Size:112 x 112 & 135 x 135 – 900 deep x 450 diameter 2 / M12 Bolts - Verandah beam to post

connection180 x 180 – 1200 deep x 450 diameter1 kN = 20 Bu’s E = 6.4 GPa. Linear interpolation between the bracing values given is permitted for intermediate heightsNote: Bracing units have been determined from the lateral load required to give a maximum deflection at the top of the post of H/150.

450 ø Post Hole

1200 or 900

minimuminto good ground

Backfill with 17.5 MPa concrete to ground

level

Post

Minimum 2 / M12

bolts, beam to post

connection

Verandah Posts GL8 - H5 Treated

100

SELECTION CHARTSPROLAM®

TABLE 16:BRACING UNITS FOR PROLAM® POSTS

50mm min

Page 22: PROLAM - Amazon Web Services · BEAM SIZES / CODES AND USES STRUCTURAL PL12 Prolam ® GL12 H3.2 KD precambered. Extra high performance beam for high load, high spanning situation

Sustainable Solutions

283 Waiwhero Rd P O Box 413 Motueka New Zealand Phone 03 526 7436 Fax 03 526 7437Email: [email protected]

The span tables apply only to Prolam® products

© Prowood Ltd

FIXING & SUPPORT DETAILS

Fixing and Support Details4T10 Tylokplate.

Top plate.

Single trimmerstud.

4T10 Tylokplate bothsides, or 8T10one side.

4T5 Tylok plateboth sides, or4T10 one side.

Doubleunderstud.

Simply Supported Beam

4T10 Tylokplate bothsides.

4T5 Tylok plateboth sides. Beam Pocket

6T15 Tylok plate

8T10 Tylok plate

Interior Use

Exterior Use

Beam

Beam

Use Bomac bracketeach side.

Single under stud up to3.6m lintel span.Double under stud over3.620m lintel span

*or equivalent

*or equivalent