CL = Ceiling mounted lights = ceiling mounted oxygen line S = ceiling mounted scavenge line = wet prep table = upper and lower cabinets REF. EP EP 8'-5 7/8" 4 1/2" 14'-10" 4 1/2" 5' 8'-6 1/2" 4 1/2" 8'-4 1/8" 4" 13'-6" 4 1/2" 9' 4' 4'-6" 6'cages 6'cages 5' tub 6'cages storage 6'cages freezer Laundry Lab/Pharmacy Exam 1 scale Break room server/ storage Closet Exam 2 Exam 3 3x5 runs S CL Surgery S S 7' cage bank CL CL exotics Kennel Office 8'-4" 7'-10" 7'-11" 4'-6" Grooming X-Ray Isolation = Existing Interior Wall = New Wall = Existing Exterior Wall LEGEND 4'-6 1/2" 4 1/2" 9'-0" 11'-10" 13'-6" 18'-10" 10'-3 1/2" 4'-10" 4'-4" 4'-4" 8'-6" 4 1/2" 12'-5 1/2" 1 1 2 3 4 5 5 5 7 =EXHAUST FAN 3'-0" 3'-0" 3' 3'-0" 3'-0" 3'-0" 10'-3 1/2" 8'-3 1/2" 10'-0 1/2" 8'-2 1/2" 1'-8 1/2" 3'-0" 4'-8" 3'-0" 10'-8" 3'-0" 3'-0" 3'-0" 4'-8" 3'-0" 3'-0" 3'-0" 3'-0" 4'-8" 3'-0" 3'-0" RECEPTION WAITING AREA (E)MAIN ENTRANCE (E) RESTROOM HALLWAY HALLWAY HALLWAY 6'cages 14/A5 10'-8" 6'-0'' 3'-0" 3'-0" 3'-0" 3'-0" 3'-0" 3'-0" 3'-0" 3'-0" 2'-0'' 2'-0" =Accessible Restroom sign 5'-2 1/2" 4'-10 1/2" LANDING D 01 - D 02 - D 03 - D 04 - D 05 - D 06 - D 07 - D 16 - D 08 - D 09 - D 10 - Treatment Room D 11 - D 12 - D 13 - D 14 - D 13 - D 15 - D 18 - D 19 - D 20 - D 21 - D 22 - WIDTH x HEIGHT SPACE DOOR SCHEDULE NEW DOOR DIMENSIONS NUMBER DOOR - X EXSITING D 01 MAIN ENTRACNE 60" X 84" X D 02 ADA RESTROOM D 03&04 EXAM ROOM #1 D 05 HALLWAY D 06&07 D 08 D 09 CLOSET D 10 TREATMENT ROOM D 11 EXOTICS D 12 X-RAY D 14 STORAGE/SERVER D 15 KENNEL D 16 D 17 GROOMING D 18 D19 D20 D21 D22 D 13 OFFICE X X X 36" X 84" - - - - - - - - - - - - - - - - - - - - - - - - - - REMARKS X 36" X 84" 36" X 84" HANDICAP ACCESSIBLE SIGN DOOR CLOSER SIZE #2,DOOR LEVER X X X EXAM ROOM #2 X 36" X 84" 36" X 84" X EXAM ROOM #3 36" X 84" X X 36" X 84" X 36" X 84" X 36" X 84" 36" X 84" X 36" X 84" X 36" X 84" X X 36" X 84" 36" X 84" ISOLATION EMERGENCY EXIT EMERGENCY EXIT X 36" X 84" 36" X 84" 36" X 84" LAUNDRY 24" X 84" EMPLOYEE RESTROOM X X 24" X 84" D23 SURGERY X 36" X 84" Note:Maximum effort to operate doors shall not exceed 5 lb for exterior and interior doors,such pull or push effort being appliled at right angles to hinged doors and at the center place of sliding or folding doors EXIT 4/A5 TYP 4/A5 TYP 4/A5 TYP PANIC HARDWARE/SELF-CLOSING PANIC HARDWARE/ SELF-CLOSING PANIC HARDWARE/ SELF-CLOSING SELF-CLOSEING DOOR LEVER, SELF-CLOSEING EXAM ROOM #3 D 17 - AREA FLOOR INTEGRAL COVED BASE 4 WAINSCOT WALLS CEILING WAITING AREA SURGERY ROOM KENNEL HALLWAYS RESTROOMS LAB/PHARMACY GROOMING FINISH SCHEDULE (E)CONCRETE / (N)EXPOXY TILES 18X18/12X6 COV DRYWALL (E)AC . TILES CERAMIC TILES TILE 6 " COVE FRP FLAG STONE TILE DRY WALL FRP/TILE 4"X4" TILE 6 " COVE TILES 12X12/12X6 COV CERAMIC TILES FRP FRP FRP DRYWALL DRYWALL SOUND PROOF DRY WAL (N)DRYWALL EQUIPMENT NO GAS CONNECTION ELECTRICAL HOT WATER COLD WATER WASTE WATER EQUIPMENT MAKE AND MODEL COMMENTS 1 2 3 4 5 WET PREP TABLE X-RAY FREEZER SCALE NEW HAND WASH SINK EQUIPMENT SCHEDULE 6 Hot Water Heater 70 GALLONS 3 4 '' 1'' 1'' 7 5' TUB 2'' 2'' (E)AC . TILES (E)AC . TILES (E)AC . TILES (E)AC . TILES (E)AC . TILES 3/4'' 3/4'' 3/4'' 3/4'' CERAMIC TILES CERAMIC TILES DRY WALL DRY WALL 3/4'' 3/4'' ELECTRIC SHEET DATE SHEET TITLE SCALE JOB NO. REVISIONS DRAWN BY DATE # 1/4" = 1' WT 06/07/17 NORTH #1 06/29/17

PROPOSED FLOOR PLAN - GLOBAL BUILDERglobalbuilder.us/wp-content/uploads/2018/10/Proposed-Floor-Plan.pdf · proposed floor plan JENNIFER DIETZ EMAIL: [email protected] CELL# 949

  • Upload
    others

  • View
    0

  • Download
    0

Embed Size (px)

Citation preview

Page 1: PROPOSED FLOOR PLAN - GLOBAL BUILDERglobalbuilder.us/wp-content/uploads/2018/10/Proposed-Floor-Plan.pdf · proposed floor plan JENNIFER DIETZ EMAIL: KESHAV@JOMIDTECH.COM CELL# 949

CL

= Ceiling mounted lights

= ceiling mounted oxygen line

S = ceiling mounted scavenge line

= wet prep table

= upper and lower cabinets

REF.

EP EP

8'-5 7/8" 4 1/2" 14'-10" 4 1/2" 5'

8'-6 1/2" 4 1/2" 8'-4 1/8"

4" 13'-6" 4 1/2" 9'

4'

4'-6"

6'cages

6'ca

ge

s

5' tu

b

6'ca

ge

s

storage

6'ca

ge

s

freezer

Laundry

Lab/Pharmacy

Exam 1

scale

Break room

server/

storageCloset

Exam 2

Exam 3

3x5 runs

S

CL

Surgery

S

S

7' cage bank

CL

CL

exotics

Kennel

Office

8'-4"

7'-10"

7'-11"

4'-6"

Grooming

X-Ray

Isolation

= Existing Interior Wall

= New Wall

= Existing Exterior Wall

LEGEND

4'-6 1/2"

4 1/2"

9'-0"

11'-10"

13'-6"

18'-10"

10'-3 1/2"

4'-10"

4'-4"

4'-4"

8'-6"

4 1/2"

12'-5 1/2"

1

1

2

3

4

5

5

5

7

=EXHAUST FAN

3'-0"

3'-0"

3'

3'-0"

3'-0"

3'-0"

10'-3 1/2"

8'-3 1/2"

10'-0 1/2"

8'-2 1/2"

1'-8 1/2"

3'-0"

4'-8"

3'-0"

10'-8"

3'-0"

3'-0"

3'-0"

4'-8"

3'-0"

3'-0"

3'-0"

3'-0"

4'-8"

3'-0"

3'-0"

RECEPTION

WAITING AREA

(E)MAIN ENTRANCE

(E) RESTROOM

HALLWAY

HALLWAY

HALLWAY

6'cages

14/A5

10'-8"

6'-0''

3'-0"

3'-0"

3'-0"

3'-0"

3'-0"

3'-0"

3'-0"

3'-0"

2'-0''

2'-0"

=Accessible Restroom sign

5'-2 1/2"

4'-10 1/2"

LANDING

D 01-

D 02-

D 03-

D 04-

D 05-D 06-

D 07-

D 16-

D 08-

D 09-

D 10-

Treatment Room

D 11-

D 12-

D 13-

D 14-

D 13-

D 15-

D 18-

D 19- D 20-

D 21-D 22-

WIDTH x HEIGHT SPACE

DOOR SCHEDULE

NEW

DOOR DIMENSIONSNUMBERDOOR

-

X

EXSIT

ING

D 01 MAIN ENTRACNE 60" X 84"

X

D 02 ADA RESTROOM

D 03&04 EXAM ROOM #1

D 05 HALLWAY

D 06&07

D 08

D 09 CLOSET

D 10 TREATMENT ROOM

D 11 EXOTICS

D 12 X-RAY

D 14 STORAGE/SERVER

D 15 KENNEL

D 16

D 17 GROOMING

D 18

D19

D20

D21

D22

D 13 OFFICE X

X

X

36" X 84"

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

REMARKS

X

36" X 84"

36" X 84"

HANDICAP ACCESSIBLE SIGN DOOR CLOSER SIZE #2,DOOR LEVER

X

X

X

EXAM ROOM #2 X 36" X 84"

36" X 84"XEXAM ROOM #3

36" X 84"X

X 36" X 84"

X 36" X 84"

X 36" X 84"

36" X 84"

X 36" X 84"

X 36" X 84"

X

X

36" X 84"

36" X 84"

ISOLATION

EMERGENCY EXIT

EMERGENCY EXIT

X 36" X 84"

36" X 84"

36" X 84"

LAUNDRY 24" X 84"EMPLOYEERESTROOM

X

X 24" X 84"

D23 SURGERY X 36" X 84"

Note:Maximum effort to operate doors shall not exceed 5 lb for exterior and interior doors,such pull or pusheffort being appliled at right angles to hinged doors and at the center place of sliding or folding doors

EXIT

4/A5 TYP

4/A5 TYP

4/A5 TYP

PANIC HARDWARE/SELF-CLOSING

PANIC HARDWARE/ SELF-CLOSING

PANIC HARDWARE/ SELF-CLOSING

SELF-CLOSEING

DOOR LEVER, SELF-CLOSEING

EXAM ROOM #3

D 17-

AREA FLOOR

INTEGRAL COVED

BASE

4 WAINSCOT WALLS CEILING

WAITING AREA

SURGERY ROOM

KENNEL

HALLWAYS

RESTROOMS

LAB/PHARMACY

GROOMING

FINISH SCHEDULE

(E)CONCRETE / (N)EXPOXY

TILES 18X18/12X6 COV DRYWALL

(E)AC . TILES

CERAMIC TILES

TILE 6 " COVE

FRP

FLAG STONE TILE

DRY WALL

FRP/TILE 4"X4"

TILE 6 " COVE

TILES 12X12/12X6 COV

CERAMIC TILES

FRP

FRP

FRP

DRYWALL

DRYWALL

SOUND PROOF

DRY WAL

(N)DRYWALL

EQ

UIP

ME

NT

N

O

GA

S C

ON

NE

CT

IO

N

EL

EC

TR

IC

AL

HO

T W

AT

ER

CO

LD

W

AT

ER

WA

ST

E W

AT

ER

EQUIPMENT MAKE

AND MODEL

COMMENTS

1

2

3

4

5

WET PREP TABLE

X-RAY

FREEZER

SCALE

NEW HAND WASH SINK

EQUIPMENT SCHEDULE

6

Hot Water Heater 70 GALLONS

3

4

''

1'' 1''

7

5' TUB

2''

2''

(E)AC . TILES

(E)AC . TILES

(E)AC . TILES

(E)AC . TILES

(E)AC . TILES

3/4''

3/4''

3/4''

3/4''

CERAMIC TILES

CERAMIC TILES

DRY WALL

DRY WALL

3/4''

3/4''

ELECTRIC

SHEET

DATE

SHEET TITLE

SCALE

JOB NO.

REVISIONS

DRAWN BY

DATE#

1/4" = 1'

WT

06/07/17

N

O

R

T

H

#1

06/29/17

AutoCAD SHX Text
AND COMPLY WITH UBC STANDARD 10-4
AutoCAD SHX Text
3. ALL RATED DOORS SHALL HAVE AN "S" LABLE.
AutoCAD SHX Text
4. PROVIDE PANIC HARDWARE FOR ALL EXIT DOORS
AutoCAD SHX Text
5. PROVIDE SELF-CLOSEING EXTERIOR AND RESTROOMS DOORS
AutoCAD SHX Text
6. MAX. OPERATING PRESSURE 5# INTERIOR & EXTERIOR DOORS
AutoCAD SHX Text
2. ALL DOOR HARDWARE & RESISTANT PRESSURE MUST COMPLY WITH A.D.A.
AutoCAD SHX Text
1. ALL DOORS SHALL BE PROVIDED WITH LEVER TYPE HARDWARE.
AutoCAD SHX Text
AND TILE 24 STANDARDS.
AutoCAD SHX Text
Doors Notes:
AutoCAD SHX Text
8.
AutoCAD SHX Text
7.
AutoCAD SHX Text
DOORS IN THE EGRESS SYSTEM TO BE OPENABLE FROM INSIDE WITHOUT ANY USE
AutoCAD SHX Text
OF A KEY OR SPECIAL KNOWLEDGE OR EFFORT (SEC. 1003.3.1.8).
AutoCAD SHX Text
9
AutoCAD SHX Text
34" AND 44" ABOVE THE FLOOR. (SEC1133B2.5.2)
AutoCAD SHX Text
HAND ACTIVATED DOOR OPENING HARDWARE SHALL BE CENTERED BETWEEN
AutoCAD SHX Text
EXIT DOORS WILL BE A MINIMUM OF 3 FEET BY 6'-8" WITH A MINIMUM DOOR
AutoCAD SHX Text
SWING OF 90 DEGREES.
AutoCAD SHX Text
EXIT
AutoCAD SHX Text
EXIT
AutoCAD SHX Text
EXIT
AutoCAD SHX Text
EXIT
AutoCAD SHX Text
EXIT
AutoCAD SHX Text
EXIT
AutoCAD SHX Text
EXIT
AutoCAD SHX Text
EXIT
AutoCAD SHX Text
EXIT
AutoCAD SHX Text
EXIT
AutoCAD SHX Text
EXIT
AutoCAD SHX Text
EXIT
AutoCAD SHX Text
EXIT
AutoCAD SHX Text
EXIT
AutoCAD SHX Text
A3
AutoCAD SHX Text
PROPOSED FLOOR PLAN
AutoCAD SHX Text
JENNIFER DIETZ EMAIL: [email protected] CELL# 949 521 1430
AutoCAD SHX Text
PROJECT ADDRESS: 3752 S BRISTOL ST ,SANTA ANA CA 92704 Designed by : Global Builders Inc (949 923 0657 )