CONSTRUCTION:ALL CONSTRUCTION SHALL COMPLY WITH THE BCA / NCC VOLUME 2 FOR CLASS 1A BUILDINGS.ENGINEERING:TO BE READ IN CONJUNCTION WITH ENGINEERING DRAWINGSAND SOIL REPORT. REFER TO ENGINEERING DRAWINGS FORSTRUCTURAL DESIGN, FOOTING AND SLAB, TIE DOWN, BRACINGAND ALL STRUCTURAL DETAILS.GLASS AND GLAZING:ALL GLAZING SHALL BE IN ACCORDANCE WITH PART 3.6 OF THE BCA / NCC AND AS 1288.POWER CONNECTION: CONNECT MAINS SUPPLY TO METER BOX VIA UNDERGROUND CONNECTION. REFER TO ELECTRICAL ENGINEER'S DRAWINGS.SET OUT:BUILDER TO CONFIRM THE SET OUT AND ALL LEVELS AND DIMENSION ON SITE PRIOR TO THE COMMENCEMENT OF THEBUILDING WORKS.SEWER CONNECTION:ALL PLUMBING POINTS TO BE CONNECTED TO SEWER AS PERCOUNCIL REQUIREMENTS AND IN ACCORDANCE WITH HYDRAULIC ENGINEER'S DRAWINGS.SMOKE ALARMS:BUILDER TO PROVIDE HARD WIRED SMOKE ALARMS IN ACCORDANCEWITH PART 3.7.2 OF THE BCA / NCC AND AS 3786.STEELWORK:ALL STEELWORK, FITTINGS AND FIXTURES SHALL BE HOT DIPPEDGALVANISED OR OF A CORROSION RESISTANT MATERIAL UNLESS NOTED OTHERWISE.
ABBREVIATIONS LEGEND:
F.F.L. FINISHED FLOOR LEVEL
F.C.L. FINISHED CEILING LEVEL
A.F.F.L ABOVE F.F.L.
B.F.C.L. BELOW FINISHED CEILING LEVEL
STRUCT. STRUCTURAL
ENG. ENGINEER
MANUF. MANUFACTURER'S
SPEC. SPECIFICATION
BCA BUILDING CODE OF AUSTRALIA
NCC NATIONAL CONSTRUCTION CODE
C.O.S. CONFIRM ON SITE
T.B.C. TO BE CONFIRMED
T.B.A. TO BE ADVISED
U.N.O. UNLESS NOTED OTHERWISE
CJ CONSTRUCTION JOINT
STORM WATER:ALL STORM WATER SHALL DISCHARGE AS PER COUNCIL REQUIREMENTSAND IN ACCORDANCE WITH HYDRAULIC ENGINEERS DRAWINGS.TERMITE PROTECTION:PROVIDE AN APPROVED PROPRIETARY TYPE TERMITE PROTECTION BARRIER TO CONCRETE SLAB AND RETAINING WALLS AS PER MANUFACTURER'S SPECIFICATION, PART 3.1.3 OF THE BCA / NCC AND AS 3600. PROVIDE TIMBER AND WOOD COMPOSITE FLOOR SEPARATION / CLEARANCES IN ACCORDANCE WITH PART 3.4.1 OF THE BCA / NCC.TIMBER:ALL TIMBER TO BE IN ACCORDANCE WITH THE BCA / NCC, AS 1684.1 AND ENGINEER'S DRAWINGS. WATERPROOFING:WATERPROOFING IN WET AREAS SHALL COMPLY WITH PART 3.8.1 OF THE BCA / NCC AND AS 3740. BUILDER TO PROVIDE A PROPRIETARY LIQUID OR SHEET MEMBRANE SYSTEM AND FALL TOWASTES.BUSHFIRE:BAL ( BUSHFIRE ATTACK LEVEL ) IS 12.5 THEREFORE HAVE TO COMPLY WITH SECTION 3 AND CLAUSES 5.2 TO 5.8 , THIS WILL APPLY TO ALL HOUSES WITHIN 100 M OF THE RAINFOREST ;5.5.1A SCREENS FOR WINDOWS AND DOORS WHERE FITTED, SCREENS FOR WINDOWS AND DOORS SHALL HAVE A MESH OR PERFORATED SHEET WITH A MAXIMUM APERTURE OF 2 MM, MADE OF CORROSION-RESISTANT STEEL, BRONZE OR ALUMINIUM. GAPS BETWEEN THE PERIMETER OF THE SCREEN ASSEMBLY AND THE BUILDING ELEMENT TO WHICH IT IS FITTED SHALL NOT EXCEED 3 MM.
SITE 88, 25 OWEN CREEK ROAD FOREST GLENSITE 88, 25 OWEN CREEK ROAD FOREST GLENSITE 88, 25 OWEN CREEK ROAD FOREST GLENSITE 88, 25 OWEN CREEK ROAD FOREST GLENPROPOSED RESIDENCE AT NATURES EDGEPROPOSED RESIDENCE AT NATURES EDGEPROPOSED RESIDENCE AT NATURES EDGEPROPOSED RESIDENCE AT NATURES EDGE
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
GENERAL NOTES
REFERENCE #SHEET #
SCALE DATE DRAWNCLIENT PROJECT
REV # DATE
QBSA Lisc No. 62679
22 Mallawa Drive
Palm Beach QLD 4211
ph 0413 801 226
[email protected] ALL DIMENSIONS BEFORE COMMENCEMENT OF
CONSTRUCTION. ALL DESIGNS ARE COPYRIGHT & REMAIN THE
PROPERTY OF PROJECT PLANNING GROUP & MARK HUDSON DESIGNS
1 : 100 JAN-18PROPOSED RESIDENCESITE 88 NATURES EDGE25 OWEN CREEK ROADFOREST GLEN
COVER
VPPROPCORP (QLD) Pty Ltd
88.C1-MDFD
B
C
05/06/2018 - window revision
11/02/2018 - client revisions
19/02/2018 - client revisions
R O A D
P R O P O S E DR E S I D E N C E
G A R A G E
fd
dp
dp
dp
dp
dp
dp
200 TO WALL
TO W
ALL
5465
TO OMP
5165
TO W
ALL
3000
TO WALL
3841
TO WALL
3823
TO OMP
3284
TO WALL
3190
TO WALL5368
TO PIER
4094
TO W
ALL
3648TO OMP
3283
TO WALL
3939
TO OMP
3400
TO WALL
4097
TO OMP
3558
dp
dp
dp
dp
dpTO OMP
2700
fdfd
fd
114° 20' 05"114° 20' 05"114° 20' 05"114° 20' 05"25200252002520025200
204°
20'
00"
204°
20'
00"
204°
20'
00"
204°
20'
00"
8265
8265
8265
8265
243°
52
' 00
"
243°
52
' 00
"
243°
52
' 00
"
243°
52
' 00
"
2825
2825
2825
2825
242°
2
0'
00"
242°
2
0'
00"
242°
2
0'
00"
242°
2
0'
00"
1561
5
1561
5
1561
5
1561
5
285° 35' 00"285° 35' 00"285° 35' 00"285° 35' 00"
8220822082208220
320° 35' 00"
320° 35' 00"
320° 35' 00"
320° 35' 00"
6325632563256325
24°
20'
05"
24°
20'
05"
24°
20'
05"
24°
20'
05"
21175
21175
21175
21175
REFERENCE #SHEET #
SCALE DATE DRAWNCLIENT PROJECT
REV # DATE
QBSA Lisc No. 62679
22 Mallawa Drive
Palm Beach QLD 4211
ph 0413 801 226
[email protected] ALL DIMENSIONS BEFORE COMMENCEMENT OF
CONSTRUCTION. ALL DESIGNS ARE COPYRIGHT & REMAIN THE
PROPERTY OF PROJECT PLANNING GROUP & MARK HUDSON DESIGNS
1 : 100 JAN-18PROPOSED RESIDENCESITE 88 NATURES EDGE25 OWEN CREEK ROADFOREST GLEN
S01.07
VPPROPCORP (QLD) Pty Ltd
88.C1-MDFD
B
C
05/06/2018 - window revision
11/02/2018 - client revisions
19/02/2018 - client revisions
1 : 100 @ A3
SSSS site plan
AREA
TOTAL 230.5m2
LIVING
GARAGEPORCH
TERRACECOURT
153.6m2
36.8m24.3m2
30.5m25.3m2
PHOTOELECTRIC SMOKE ALARMSTO BE POSITIONED IN BUILDING
TO COMPLY WITH BCA CLASS 1-10 PART 3.7.2 AND WITH A.S.3786
NOTE
PROVIDE WATERPROOF MEMBRANE TO BASE OF HEBEL PANELS TO DRYING COURT AND
TERRACE/PORCH COLUMNS
FLUORESCENT LIGHTS AND COMPACT FLUORESCENT LIGHTS (CFLS) TO 80% OF TOTAL
FIXED ARTIFICIAL LIGHTING THAT COMPLIES WITH PART 3.12.5.5 OF THE BCA.
NOTE: NOGGINGS - LAUNDRY DRYER @ 2200H- WC HOLDERS @ 650h- GRAB RAILS ENSUITE & BATH @ 800H- GARAGE DOOR MOTOR & RAILS
ALLOW 20mm STEPDOWN TO ALL
SLIDING DOORS & ENTRANCE DOOR
CUSTOM
DESIGN:
pch
bed 1
tce
living
meals
garage
kitch
rangehood
to be ducted
hosecock
(dam)
MH 600X1200
R O B E
wm
350x350 Hebel clad column galv.
steel post & framing to engineers
detail texture render finish
hosecock
(town)
RAKED
CEILING
OVER
7130TCE5400 4940 2170
5710 450PCH1260 450 3490 2040 2120 1020 930 2170
2800
2970
1130
950
1720
4040
300
1000
1000
14060
450
900
6140
2540
4030
19640
bed 2
crt
ldy
mpr
bath
ens.
store
wir
ent
dp
dp
dp
dp
dpdp
dp
dp
dp
dp
dp
R O B E
woref
dw
r/hpty
L I N E NBRRAKED
CEILING
OVER
hosecock
(town)
2200x4800 PLD
920
SL82
0csd
770C
SD
770CSD
770C
SD
770CSD
770CSD
820csd
820
820
2442SD_OXXO
2118
SD
2115SD
2115SD
sl.dr.
sl.dr.
sl.dr.
1206
DH
1206DH
1206DH
1206DH
2430 SD
1524SW_OXXO
1507
5DH
1827SW_OXXO1815SW_XO
70
LDY
1700
90
MPR
2000
170
170
GARAGE
5900
70 600
1200
900
MEALS
3700
PCH
1600
170
ENT
4300
701800
2200
2400
2950
170
1170
3130
170
STORE
3700
170
170
4000
90
ENS
1630
950
170
WIR
3810
ROBE
2330
70
LIVING
5500
70
BATH
2800
170
170
BED 2
3880
901030
LIN
600
TCE
2400
170
170MPR2970
70
MEALS3750 170 170 600
BED 14000 170
70STORE2100 170
LDY1900
90
KITCHEN4800 6270
CRT2090 70 3600 1200 70
LIVING6200 70
WIR1650
70
ENS2280 170 2170
6160 170RO600
BED 23000 170
170GARAGE5820 90
ENT1440 3670 90
BATH1950 170
1740 70LINEN3300
541070
WIR1650 500 70
1350170
930
FIXED GLAZING OVER
fd
bulkhead
over @ 2550
450dia skylight
450dia
skylight
hamper @ 2550h
45L s/steel laundry tub
opaque glazing to window
RAKED
CEILIN
G
raked ceiling
to store
electrical metre
box location
'RIFCO' 3 door rebated mirror
cabinet over vanity
(1200x700x130) supplied by client
REFERENCE #SHEET #
SCALE DATE DRAWNCLIENT PROJECT
REV # DATE
QBSA Lisc No. 62679
22 Mallawa Drive
Palm Beach QLD 4211
ph 0413 801 226
[email protected] ALL DIMENSIONS BEFORE COMMENCEMENT OF
CONSTRUCTION. ALL DESIGNS ARE COPYRIGHT & REMAIN THE
PROPERTY OF PROJECT PLANNING GROUP & MARK HUDSON DESIGNS
1 : 100 JAN-18PROPOSED RESIDENCESITE 88 NATURES EDGE25 OWEN CREEK ROADFOREST GLEN
S02.07
VPPROPCORP (QLD) Pty Ltd
88.C1-MDFD
B
C
05/06/2018 - window revision
11/02/2018 - client revisions
19/02/2018 - client revisions
1 : 100 @ A3
FFFF floor plan
• COLORBOND CUSTOMORB ROOFING FIXED IN ACCORDANCE WITH MANUFACTURERS SPECIFICATIONS• ROOF PITCH = SHOWN°
• EAVES PROJ. = SHOWN• SARKING / BONDED BLANKET INSULATION TO ROOF
7.5
°
10.0°
2.0°
10.0°
10.0°
450450 300
300
450
300
450
300450
300
300
300
450
450
450
300
300
450
450
300
450
300
10.0°
10.0°
10.0°
10.0°
& 2.0°
R.C. FOOTINGSTO ENG. DETAILS
ALUMINIUM FRAMED JOINERYPOWDER COAT FINISH
TEXTURE RENDER FINISH TO HEBEL POWERT PANELS AS PER
MANUFACTURERS SPEC'S
COLORBONDMETAL FASCIA
AND GUTTER
F.C. SOFFIT LINING
R.C. SLAB TO ENG. DETAILS ON0.2mm THICK POLY. MEMBRANE
ON MIN. 50mm BED SAND
10mm PLASTERBOARDWALL & CEILING LININING
BACKBLOCKED TOMANUFAC. SPEC'S.
METAL ROOFTRUSSES @ 600 C/S
OVERHANG
2550 FINISHED FLOOR LEVEL TO U.S. TRUSS
COLORBOND CUSTOMORB ROOFINGFIXED IN ACCORDANCE WITH MANUF.
SPECS ON METAL BATTENS
450
WEATHER STRIP
ALLOW 10mm GAP
MAX
250
STEEL STUDFRAME
SCREW FIXING
2100 W
INDOW & DOOR JOINERY HEIGHT
REFERENCE #SHEET #
SCALE DATE DRAWNCLIENT PROJECT
REV # DATE
QBSA Lisc No. 62679
22 Mallawa Drive
Palm Beach QLD 4211
ph 0413 801 226
[email protected] ALL DIMENSIONS BEFORE COMMENCEMENT OF
CONSTRUCTION. ALL DESIGNS ARE COPYRIGHT & REMAIN THE
PROPERTY OF PROJECT PLANNING GROUP & MARK HUDSON DESIGNS
SHOWN JAN-18PROPOSED RESIDENCESITE 88 NATURES EDGE25 OWEN CREEK ROADFOREST GLEN
S03.07
VPPROPCORP (QLD) Pty Ltd
88.C1-MDFD
B
C
05/06/2018 - window revision
11/02/2018 - client revisions
19/02/2018 - client revisions
1 : 100 @ A3
RRRR roof plan1 : 20 @ A3
SSSS
typicalsection
PITCHING HEIGHT
2740
texture render finish to 100mm hebelpanels fixed as per manufac's spec's
aluminium framed joineryselected powdercoat finish
colorbond metal fascia & gutter
colorbond metal sheet roofingfixed to manufacturers spec's.
cj cj
hardies "linea" cladding fixedper manufacturers spec's.
TERRACE PITCHING
2550
PITCHING HEIGHT
2740
colorbond metal fascia & gutter
hardies "linea" cladding fixedper manufacturers spec's.
colorbond metal sheet roofingfixed to manufacturers spec's.
texture render finish to 100mm hebelpanels fixed as per manufac's spec's
aluminium framed joineryselected powdercoat finish
PITCHING HEIGHT
2740
hardies "linea" cladding fixedper manufacturers spec's.
texture render finish to 100mm hebelpanels fixed as per manufac's spec's
colorbond metal fascia & gutter
cj
aluminium framed joineryselected powdercoat finish
selected remotepanel lift door.
selected timber framed entry door with fixed glass side light
cj 450
2200
BED 2 PITCHING
2550
PITCHING HEIGHT
2740
aluminium framed joineryselected powdercoat finish
colorbond metal fascia & gutter
colorbond metal sheet roofingfixed to manufacturers spec's.
cj
350x350 Hebel clad column galv.steel post & framing to engineersdetail texture render finish
hardies "linea" cladding fixedper manufacturers spec's.
REFERENCE #SHEET #
SCALE DATE DRAWNCLIENT PROJECT
REV # DATE
QBSA Lisc No. 62679
22 Mallawa Drive
Palm Beach QLD 4211
ph 0413 801 226
[email protected] ALL DIMENSIONS BEFORE COMMENCEMENT OF
CONSTRUCTION. ALL DESIGNS ARE COPYRIGHT & REMAIN THE
PROPERTY OF PROJECT PLANNING GROUP & MARK HUDSON DESIGNS
1 : 100 JAN-18PROPOSED RESIDENCESITE 88 NATURES EDGE25 OWEN CREEK ROADFOREST GLEN
S04.07
VPPROPCORP (QLD) Pty Ltd
88.C1-MDFD
B
C
05/06/2018 - window revision
11/02/2018 - client revisions
19/02/2018 - client revisions
1 : 100 @ A3
SSSS south elevation1 : 100 @ A3
WWWW west elevation
1 : 100 @ A3
NNNN north elevation1 : 100 @ A3
EEEE east elevation
"KEEP FACE OF SLAB LEVEL"
F A L L
50mm recessto shower
fd
100mm x 45mm deep rebate
100m
m x 45m
m deep rebate
100mm x 45mm deep rebate
provide clean edge tofooting and slab face
NOTE
- ALLOW FOR 20mm REBATE TO ALL SLIDING DOOR POSITIONS & ENTRY DOOR.
- SLAB TO BE FINISHED FOR DIRECT STICK TILES WHERE NOTED. REFER TO FLOOR PLAN
50mm step
150m
m step
150mm step
100mm x 45mm deep rebate
50mm recessto shower
F A L L
F A L L
50mm recessto shower
50mm step
50mm step
100m
m x 45m
m
deep rebate
100mm x 45mm deep rebate
150mm step
50mm step
50mm step
290
680 4800 680
1350
6140
2540
4030
1000
1200 17270 1170
7130 5400 4940 2170
5710 1710 450 3490 2040 2120 1020 930 2170
6160 1260
150
2800
2970
1130
950
1720
4040
300
1000
15060 23
232
17407
3400
4470
8240
1580
7440
1100
11280 1000 1120
5890
950
170
12930 1350 170
600 4200 600
465
1810
125
365 1510 215
365 1510 215
REFERENCE #SHEET #
SCALE DATE DRAWNCLIENT PROJECT
REV # DATE
QBSA Lisc No. 62679
22 Mallawa Drive
Palm Beach QLD 4211
ph 0413 801 226
[email protected] ALL DIMENSIONS BEFORE COMMENCEMENT OF
CONSTRUCTION. ALL DESIGNS ARE COPYRIGHT & REMAIN THE
PROPERTY OF PROJECT PLANNING GROUP & MARK HUDSON DESIGNS
1 : 100 JAN-18PROPOSED RESIDENCESITE 88 NATURES EDGE25 OWEN CREEK ROADFOREST GLEN
S05.07
VPPROPCORP (QLD) Pty Ltd
88.C1-MDFD
B
C
05/06/2018 - window revision
11/02/2018 - client revisions
19/02/2018 - client revisions
1 : 100 @ A3
SSSS slab setout
TELEVISION OUTLET
TELEPHONE OUTLET
FLURO TUBE LIGHT
WALL LIGHT
SWITCH POSITION
EXHAUST FAN/HEATER/LIGHT
DOWNLIGHT
METER BOARD
legend
EXHAUST
JUNCTION BOXJB
AIRCON UNIT
GPO
CEILING FAN
S SPOT LIGHT & SENSOR )
ISOLATOR
F FOXTEL PROVISIONS
BUNKER LIGHT
FEATURE LIGHT
NBN NBN BOX
EXTERNAL DOWNLIGHT
PHOTOELECTRIC SMOKE ALARMSTO BE POSITIONED IN BUILDING TO
COMPLY WITH BCA CLASS 1-10 PART 3.7.2 AND WITH A.S.3786
GAS POINT
A/C
INT INTERCOM
UNDER BENCH
FOR WM/DR
E
A/C
2W
2W
2W
2W
2W
2W
F
NBN
A/C UNIT LOCATION
TBD BY CONTRACTOR A/C
SWITCHED
ON DOOR
REFERENCE #SHEET #
SCALE DATE DRAWNCLIENT PROJECT
REV # DATE
QBSA Lisc No. 62679
22 Mallawa Drive
Palm Beach QLD 4211
ph 0413 801 226
[email protected] ALL DIMENSIONS BEFORE COMMENCEMENT OF
CONSTRUCTION. ALL DESIGNS ARE COPYRIGHT & REMAIN THE
PROPERTY OF PROJECT PLANNING GROUP & MARK HUDSON DESIGNS
1 : 100 JAN-18PROPOSED RESIDENCESITE 88 NATURES EDGE25 OWEN CREEK ROADFOREST GLEN
S06.07
VPPROPCORP (QLD) Pty Ltd
88.C1-MDFD
B
C
05/06/2018 - window revision
11/02/2018 - client revisions
19/02/2018 - client revisions
1 : 100 @ A3
EEEE electrical plan
SILL DETAIL
OPTION 1 - SIDE & REAR
WALLS ONLY
HEADER DETAIL
ROOF EAVES
DETAIL
GARAGE HEAD
DETAIL
GARAGE DOOR
JAMB DETAIL
OPTION 1
OPTION 2
SILL DETAIL
OPTION 2 - STREET FACING
WALLS ONLY
TYPICAL SLAB/PATIO/
PORCH PATH SECTION
TYPICAL GARAGE SLAB/
DRIVEWAY SECTION
TYPICAL SLAB
SECTION100
75
25
4510
5
290
REFERENCE #SHEET #
SCALE DATE DRAWNCLIENT PROJECT
REV # DATE
QBSA Lisc No. 62679
22 Mallawa Drive
Palm Beach QLD 4211
ph 0413 801 226
[email protected] ALL DIMENSIONS BEFORE COMMENCEMENT OF
CONSTRUCTION. ALL DESIGNS ARE COPYRIGHT & REMAIN THE
PROPERTY OF PROJECT PLANNING GROUP & MARK HUDSON DESIGNS
SHOWN JAN-18PROPOSED RESIDENCESITE 88 NATURES EDGE25 OWEN CREEK ROADFOREST GLEN
S07.07
VPPROPCORP (QLD) Pty Ltd
88.C1-MDFD
B
C
05/06/2018 - window revision
11/02/2018 - client revisions
19/02/2018 - client revisions