8
CONSTRUCTION: ALL CONSTRUCTION SHALL COMPLY WITH THE BCA / NCC VOLUME 2 FOR CLASS 1A BUILDINGS. ENGINEERING: TO BE READ IN CONJUNCTION WITH ENGINEERING DRAWINGS AND SOIL REPORT. REFER TO ENGINEERING DRAWINGS FOR STRUCTURAL DESIGN, FOOTING AND SLAB, TIE DOWN, BRACING AND ALL STRUCTURAL DETAILS. GLASS AND GLAZING: ALL GLAZING SHALL BE IN ACCORDANCE WITH PART 3.6 OF THE BCA / NCC AND AS 1288. POWER CONNECTION: CONNECT MAINS SUPPLY TO METER BOX VIA UNDERGROUND CONNECTION. REFER TO ELECTRICAL ENGINEER'S DRAWINGS. SET OUT: BUILDER TO CONFIRM THE SET OUT AND ALL LEVELS AND DIMENSION ON SITE PRIOR TO THE COMMENCEMENT OF THE BUILDING WORKS. SEWER CONNECTION: ALL PLUMBING POINTS TO BE CONNECTED TO SEWER AS PER COUNCIL REQUIREMENTS AND IN ACCORDANCE WITH HYDRAULIC ENGINEER'S DRAWINGS. SMOKE ALARMS: BUILDER TO PROVIDE HARD WIRED SMOKE ALARMS IN ACCORDANCE WITH PART 3.7.2 OF THE BCA / NCC AND AS 3786. STEELWORK: ALL STEELWORK, FITTINGS AND FIXTURES SHALL BE HOT DIPPED GALVANISED OR OF A CORROSION RESISTANT MATERIAL UNLESS NOTED OTHERWISE. ABBREVIATIONS LEGEND: F.F.L. FINISHED FLOOR LEVEL F.C.L. FINISHED CEILING LEVEL A.F.F.L ABOVE F.F.L. B.F.C.L. BELOW FINISHED CEILING LEVEL STRUCT. STRUCTURAL ENG. ENGINEER MANUF. MANUFACTURER'S SPEC. SPECIFICATION BCA BUILDING CODE OF AUSTRALIA NCC NATIONAL CONSTRUCTION CODE C.O.S. CONFIRM ON SITE T.B.C. TO BE CONFIRMED T.B.A. TO BE ADVISED U.N.O. UNLESS NOTED OTHERWISE CJ CONSTRUCTION JOINT STORM WATER: ALL STORM WATER SHALL DISCHARGE AS PER COUNCIL REQUIREMENTS AND IN ACCORDANCE WITH HYDRAULIC ENGINEERS DRAWINGS. TERMITE PROTECTION: PROVIDE AN APPROVED PROPRIETARY TYPE TERMITE PROTECTION BARRIER TO CONCRETE SLAB AND RETAINING WALLS AS PER MANUFACTURER'S SPECIFICATION, PART 3.1.3 OF THE BCA / NCC AND AS 3600. PROVIDE TIMBER AND WOOD COMPOSITE FLOOR SEPARATION / CLEARANCES IN ACCORDANCE WITH PART 3.4.1 OF THE BCA / NCC. TIMBER: ALL TIMBER TO BE IN ACCORDANCE WITH THE BCA / NCC, AS 1684.1 AND ENGINEER'S DRAWINGS. WATERPROOFING: WATERPROOFING IN WET AREAS SHALL COMPLY WITH PART 3.8.1 OF THE BCA / NCC AND AS 3740. BUILDER TO PROVIDE A PROPRIETARY LIQUID OR SHEET MEMBRANE SYSTEM AND FALL TO WASTES. BUSHFIRE: BAL ( BUSHFIRE ATTACK LEVEL ) IS 12.5 THEREFORE HAVE TO COMPLY WITH SECTION 3 AND CLAUSES 5.2 TO 5.8 , THIS WILL APPLY TO ALL HOUSES WITHIN 100 M OF THE RAINFOREST ; 5.5.1A SCREENS FOR WINDOWS AND DOORS WHERE FITTED, SCREENS FOR WINDOWS AND DOORS SHALL HAVE A MESH OR PERFORATED SHEET WITH A MAXIMUM APERTURE OF 2 MM, MADE OF CORROSION -RESISTANT STEEL, BRONZE OR ALUMINIUM. GAPS BETWEEN THE PERIMETER OF THE SCREEN ASSEMBLY AND THE BUILDING ELEMENT TO WHICH IT IS FITTED SHALL NOT EXCEED 3 MM. SITE 88, 25 OWEN CREEK ROAD FOREST GLEN SITE 88, 25 OWEN CREEK ROAD FOREST GLEN SITE 88, 25 OWEN CREEK ROAD FOREST GLEN SITE 88, 25 OWEN CREEK ROAD FOREST GLEN PROPOSED RESIDENCE AT NATURES EDGE PROPOSED RESIDENCE AT NATURES EDGE PROPOSED RESIDENCE AT NATURES EDGE PROPOSED RESIDENCE AT NATURES EDGE 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. GENERAL NOTES REFERENCE # SHEET # SCALE DATE DRAWN CLIENT PROJECT REV # DATE QBSA Lisc No. 62679 22 Mallawa Drive Palm Beach QLD 4211 ph 0413 801 226 email [email protected] CHECK ALL DIMENSIONS BEFORE COMMENCEMENT OF CONSTRUCTION. ALL DESIGNS ARE COPYRIGHT & REMAIN THE PROPERTY OF PROJECT PLANNING GROUP & MARK HUDSON DESIGNS 1 : 100 JAN-18 PROPOSED RESIDENCE SITE 88 NATURES EDGE 25 OWEN CREEK ROAD FOREST GLEN COVER VP PROPCORP (QLD) Pty Ltd 88.C1-MDF D B C 05/06/2018 - window revision 11/02/2018 - client revisions 19/02/2018 - client revisions

PROPOSED RESIDENCE AT NATURES EDGEtrade.ausmargroup.com.au/wp-content/uploads/2018/06/LOT-88-NA… · panel lift door. selected timber framed entry door with fixed glass side light

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

Page 1: PROPOSED RESIDENCE AT NATURES EDGEtrade.ausmargroup.com.au/wp-content/uploads/2018/06/LOT-88-NA… · panel lift door. selected timber framed entry door with fixed glass side light

CONSTRUCTION:ALL CONSTRUCTION SHALL COMPLY WITH THE BCA / NCC VOLUME 2 FOR CLASS 1A BUILDINGS.ENGINEERING:TO BE READ IN CONJUNCTION WITH ENGINEERING DRAWINGSAND SOIL REPORT. REFER TO ENGINEERING DRAWINGS FORSTRUCTURAL DESIGN, FOOTING AND SLAB, TIE DOWN, BRACINGAND ALL STRUCTURAL DETAILS.GLASS AND GLAZING:ALL GLAZING SHALL BE IN ACCORDANCE WITH PART 3.6 OF THE BCA / NCC AND AS 1288.POWER CONNECTION: CONNECT MAINS SUPPLY TO METER BOX VIA UNDERGROUND CONNECTION. REFER TO ELECTRICAL ENGINEER'S DRAWINGS.SET OUT:BUILDER TO CONFIRM THE SET OUT AND ALL LEVELS AND DIMENSION ON SITE PRIOR TO THE COMMENCEMENT OF THEBUILDING WORKS.SEWER CONNECTION:ALL PLUMBING POINTS TO BE CONNECTED TO SEWER AS PERCOUNCIL REQUIREMENTS AND IN ACCORDANCE WITH HYDRAULIC ENGINEER'S DRAWINGS.SMOKE ALARMS:BUILDER TO PROVIDE HARD WIRED SMOKE ALARMS IN ACCORDANCEWITH PART 3.7.2 OF THE BCA / NCC AND AS 3786.STEELWORK:ALL STEELWORK, FITTINGS AND FIXTURES SHALL BE HOT DIPPEDGALVANISED OR OF A CORROSION RESISTANT MATERIAL UNLESS NOTED OTHERWISE.

ABBREVIATIONS LEGEND:

F.F.L. FINISHED FLOOR LEVEL

F.C.L. FINISHED CEILING LEVEL

A.F.F.L ABOVE F.F.L.

B.F.C.L. BELOW FINISHED CEILING LEVEL

STRUCT. STRUCTURAL

ENG. ENGINEER

MANUF. MANUFACTURER'S

SPEC. SPECIFICATION

BCA BUILDING CODE OF AUSTRALIA

NCC NATIONAL CONSTRUCTION CODE

C.O.S. CONFIRM ON SITE

T.B.C. TO BE CONFIRMED

T.B.A. TO BE ADVISED

U.N.O. UNLESS NOTED OTHERWISE

CJ CONSTRUCTION JOINT

STORM WATER:ALL STORM WATER SHALL DISCHARGE AS PER COUNCIL REQUIREMENTSAND IN ACCORDANCE WITH HYDRAULIC ENGINEERS DRAWINGS.TERMITE PROTECTION:PROVIDE AN APPROVED PROPRIETARY TYPE TERMITE PROTECTION BARRIER TO CONCRETE SLAB AND RETAINING WALLS AS PER MANUFACTURER'S SPECIFICATION, PART 3.1.3 OF THE BCA / NCC AND AS 3600. PROVIDE TIMBER AND WOOD COMPOSITE FLOOR SEPARATION / CLEARANCES IN ACCORDANCE WITH PART 3.4.1 OF THE BCA / NCC.TIMBER:ALL TIMBER TO BE IN ACCORDANCE WITH THE BCA / NCC, AS 1684.1 AND ENGINEER'S DRAWINGS. WATERPROOFING:WATERPROOFING IN WET AREAS SHALL COMPLY WITH PART 3.8.1 OF THE BCA / NCC AND AS 3740. BUILDER TO PROVIDE A PROPRIETARY LIQUID OR SHEET MEMBRANE SYSTEM AND FALL TOWASTES.BUSHFIRE:BAL ( BUSHFIRE ATTACK LEVEL ) IS 12.5 THEREFORE HAVE TO COMPLY WITH SECTION 3 AND CLAUSES 5.2 TO 5.8 , THIS WILL APPLY TO ALL HOUSES WITHIN 100 M OF THE RAINFOREST ;5.5.1A SCREENS FOR WINDOWS AND DOORS WHERE FITTED, SCREENS FOR WINDOWS AND DOORS SHALL HAVE A MESH OR PERFORATED SHEET WITH A MAXIMUM APERTURE OF 2 MM, MADE OF CORROSION-RESISTANT STEEL, BRONZE OR ALUMINIUM. GAPS BETWEEN THE PERIMETER OF THE SCREEN ASSEMBLY AND THE BUILDING ELEMENT TO WHICH IT IS FITTED SHALL NOT EXCEED 3 MM.

SITE 88, 25 OWEN CREEK ROAD FOREST GLENSITE 88, 25 OWEN CREEK ROAD FOREST GLENSITE 88, 25 OWEN CREEK ROAD FOREST GLENSITE 88, 25 OWEN CREEK ROAD FOREST GLENPROPOSED RESIDENCE AT NATURES EDGEPROPOSED RESIDENCE AT NATURES EDGEPROPOSED RESIDENCE AT NATURES EDGEPROPOSED RESIDENCE AT NATURES EDGE

1.

2.

3.

4.

5.

6.

7.

8.

9.

10.

11.

12.

13.

GENERAL NOTES

REFERENCE #SHEET #

SCALE DATE DRAWNCLIENT PROJECT

REV # DATE

QBSA Lisc No. 62679

22 Mallawa Drive

Palm Beach QLD 4211

ph 0413 801 226

email

[email protected] ALL DIMENSIONS BEFORE COMMENCEMENT OF

CONSTRUCTION. ALL DESIGNS ARE COPYRIGHT & REMAIN THE

PROPERTY OF PROJECT PLANNING GROUP & MARK HUDSON DESIGNS

1 : 100 JAN-18PROPOSED RESIDENCESITE 88 NATURES EDGE25 OWEN CREEK ROADFOREST GLEN

COVER

VPPROPCORP (QLD) Pty Ltd

88.C1-MDFD

B

C

05/06/2018 - window revision

11/02/2018 - client revisions

19/02/2018 - client revisions

Page 2: PROPOSED RESIDENCE AT NATURES EDGEtrade.ausmargroup.com.au/wp-content/uploads/2018/06/LOT-88-NA… · panel lift door. selected timber framed entry door with fixed glass side light

R O A D

P R O P O S E DR E S I D E N C E

G A R A G E

fd

dp

dp

dp

dp

dp

dp

200 TO WALL

TO W

ALL

5465

TO OMP

5165

TO W

ALL

3000

TO WALL

3841

TO WALL

3823

TO OMP

3284

TO WALL

3190

TO WALL5368

TO PIER

4094

TO W

ALL

3648TO OMP

3283

TO WALL

3939

TO OMP

3400

TO WALL

4097

TO OMP

3558

dp

dp

dp

dp

dpTO OMP

2700

fdfd

fd

114° 20' 05"114° 20' 05"114° 20' 05"114° 20' 05"25200252002520025200

204°

20'

00"

204°

20'

00"

204°

20'

00"

204°

20'

00"

8265

8265

8265

8265

243°

52

' 00

"

243°

52

' 00

"

243°

52

' 00

"

243°

52

' 00

"

2825

2825

2825

2825

242°

2

0'

00"

242°

2

0'

00"

242°

2

0'

00"

242°

2

0'

00"

1561

5

1561

5

1561

5

1561

5

285° 35' 00"285° 35' 00"285° 35' 00"285° 35' 00"

8220822082208220

320° 35' 00"

320° 35' 00"

320° 35' 00"

320° 35' 00"

6325632563256325

24°

20'

05"

24°

20'

05"

24°

20'

05"

24°

20'

05"

21175

21175

21175

21175

REFERENCE #SHEET #

SCALE DATE DRAWNCLIENT PROJECT

REV # DATE

QBSA Lisc No. 62679

22 Mallawa Drive

Palm Beach QLD 4211

ph 0413 801 226

email

[email protected] ALL DIMENSIONS BEFORE COMMENCEMENT OF

CONSTRUCTION. ALL DESIGNS ARE COPYRIGHT & REMAIN THE

PROPERTY OF PROJECT PLANNING GROUP & MARK HUDSON DESIGNS

1 : 100 JAN-18PROPOSED RESIDENCESITE 88 NATURES EDGE25 OWEN CREEK ROADFOREST GLEN

S01.07

VPPROPCORP (QLD) Pty Ltd

88.C1-MDFD

B

C

05/06/2018 - window revision

11/02/2018 - client revisions

19/02/2018 - client revisions

1 : 100 @ A3

SSSS site plan

Page 3: PROPOSED RESIDENCE AT NATURES EDGEtrade.ausmargroup.com.au/wp-content/uploads/2018/06/LOT-88-NA… · panel lift door. selected timber framed entry door with fixed glass side light

AREA

TOTAL 230.5m2

LIVING

GARAGEPORCH

TERRACECOURT

153.6m2

36.8m24.3m2

30.5m25.3m2

PHOTOELECTRIC SMOKE ALARMSTO BE POSITIONED IN BUILDING

TO COMPLY WITH BCA CLASS 1-10 PART 3.7.2 AND WITH A.S.3786

NOTE

PROVIDE WATERPROOF MEMBRANE TO BASE OF HEBEL PANELS TO DRYING COURT AND

TERRACE/PORCH COLUMNS

FLUORESCENT LIGHTS AND COMPACT FLUORESCENT LIGHTS (CFLS) TO 80% OF TOTAL

FIXED ARTIFICIAL LIGHTING THAT COMPLIES WITH PART 3.12.5.5 OF THE BCA.

NOTE: NOGGINGS - LAUNDRY DRYER @ 2200H- WC HOLDERS @ 650h- GRAB RAILS ENSUITE & BATH @ 800H- GARAGE DOOR MOTOR & RAILS

ALLOW 20mm STEPDOWN TO ALL

SLIDING DOORS & ENTRANCE DOOR

CUSTOM

DESIGN:

pch

bed 1

tce

living

meals

garage

kitch

rangehood

to be ducted

hosecock

(dam)

MH 600X1200

R O B E

wm

350x350 Hebel clad column galv.

steel post & framing to engineers

detail texture render finish

hosecock

(town)

RAKED

CEILING

OVER

7130TCE5400 4940 2170

5710 450PCH1260 450 3490 2040 2120 1020 930 2170

2800

2970

1130

950

1720

4040

300

1000

1000

14060

450

900

6140

2540

4030

19640

bed 2

crt

ldy

mpr

bath

ens.

store

wir

ent

dp

dp

dp

dp

dpdp

dp

dp

dp

dp

dp

R O B E

woref

dw

r/hpty

L I N E NBRRAKED

CEILING

OVER

hosecock

(town)

2200x4800 PLD

920

SL82

0csd

770C

SD

770CSD

770C

SD

770CSD

770CSD

820csd

820

820

2442SD_OXXO

2118

SD

2115SD

2115SD

sl.dr.

sl.dr.

sl.dr.

1206

DH

1206DH

1206DH

1206DH

2430 SD

1524SW_OXXO

1507

5DH

1827SW_OXXO1815SW_XO

70

LDY

1700

90

MPR

2000

170

170

GARAGE

5900

70 600

1200

900

MEALS

3700

PCH

1600

170

ENT

4300

701800

2200

2400

2950

170

1170

3130

170

STORE

3700

170

170

4000

90

ENS

1630

950

170

WIR

3810

ROBE

2330

70

LIVING

5500

70

BATH

2800

170

170

BED 2

3880

901030

LIN

600

TCE

2400

170

170MPR2970

70

MEALS3750 170 170 600

BED 14000 170

70STORE2100 170

LDY1900

90

KITCHEN4800 6270

CRT2090 70 3600 1200 70

LIVING6200 70

WIR1650

70

ENS2280 170 2170

6160 170RO600

BED 23000 170

170GARAGE5820 90

ENT1440 3670 90

BATH1950 170

1740 70LINEN3300

541070

WIR1650 500 70

1350170

930

FIXED GLAZING OVER

fd

bulkhead

over @ 2550

450dia skylight

450dia

skylight

hamper @ 2550h

45L s/steel laundry tub

opaque glazing to window

RAKED

CEILIN

G

raked ceiling

to store

electrical metre

box location

'RIFCO' 3 door rebated mirror

cabinet over vanity

(1200x700x130) supplied by client

REFERENCE #SHEET #

SCALE DATE DRAWNCLIENT PROJECT

REV # DATE

QBSA Lisc No. 62679

22 Mallawa Drive

Palm Beach QLD 4211

ph 0413 801 226

email

[email protected] ALL DIMENSIONS BEFORE COMMENCEMENT OF

CONSTRUCTION. ALL DESIGNS ARE COPYRIGHT & REMAIN THE

PROPERTY OF PROJECT PLANNING GROUP & MARK HUDSON DESIGNS

1 : 100 JAN-18PROPOSED RESIDENCESITE 88 NATURES EDGE25 OWEN CREEK ROADFOREST GLEN

S02.07

VPPROPCORP (QLD) Pty Ltd

88.C1-MDFD

B

C

05/06/2018 - window revision

11/02/2018 - client revisions

19/02/2018 - client revisions

1 : 100 @ A3

FFFF floor plan

Page 4: PROPOSED RESIDENCE AT NATURES EDGEtrade.ausmargroup.com.au/wp-content/uploads/2018/06/LOT-88-NA… · panel lift door. selected timber framed entry door with fixed glass side light

• COLORBOND CUSTOMORB ROOFING FIXED IN ACCORDANCE WITH MANUFACTURERS SPECIFICATIONS• ROOF PITCH = SHOWN°

• EAVES PROJ. = SHOWN• SARKING / BONDED BLANKET INSULATION TO ROOF

7.5

°

10.0°

2.0°

10.0°

10.0°

450450 300

300

450

300

450

300450

300

300

300

450

450

450

300

300

450

450

300

450

300

10.0°

10.0°

10.0°

10.0°

& 2.0°

R.C. FOOTINGSTO ENG. DETAILS

ALUMINIUM FRAMED JOINERYPOWDER COAT FINISH

TEXTURE RENDER FINISH TO HEBEL POWERT PANELS AS PER

MANUFACTURERS SPEC'S

COLORBONDMETAL FASCIA

AND GUTTER

F.C. SOFFIT LINING

R.C. SLAB TO ENG. DETAILS ON0.2mm THICK POLY. MEMBRANE

ON MIN. 50mm BED SAND

10mm PLASTERBOARDWALL & CEILING LININING

BACKBLOCKED TOMANUFAC. SPEC'S.

METAL ROOFTRUSSES @ 600 C/S

OVERHANG

2550 FINISHED FLOOR LEVEL TO U.S. TRUSS

COLORBOND CUSTOMORB ROOFINGFIXED IN ACCORDANCE WITH MANUF.

SPECS ON METAL BATTENS

450

WEATHER STRIP

ALLOW 10mm GAP

MAX

250

STEEL STUDFRAME

SCREW FIXING

2100 W

INDOW & DOOR JOINERY HEIGHT

REFERENCE #SHEET #

SCALE DATE DRAWNCLIENT PROJECT

REV # DATE

QBSA Lisc No. 62679

22 Mallawa Drive

Palm Beach QLD 4211

ph 0413 801 226

email

[email protected] ALL DIMENSIONS BEFORE COMMENCEMENT OF

CONSTRUCTION. ALL DESIGNS ARE COPYRIGHT & REMAIN THE

PROPERTY OF PROJECT PLANNING GROUP & MARK HUDSON DESIGNS

SHOWN JAN-18PROPOSED RESIDENCESITE 88 NATURES EDGE25 OWEN CREEK ROADFOREST GLEN

S03.07

VPPROPCORP (QLD) Pty Ltd

88.C1-MDFD

B

C

05/06/2018 - window revision

11/02/2018 - client revisions

19/02/2018 - client revisions

1 : 100 @ A3

RRRR roof plan1 : 20 @ A3

SSSS

typicalsection

Page 5: PROPOSED RESIDENCE AT NATURES EDGEtrade.ausmargroup.com.au/wp-content/uploads/2018/06/LOT-88-NA… · panel lift door. selected timber framed entry door with fixed glass side light

PITCHING HEIGHT

2740

texture render finish to 100mm hebelpanels fixed as per manufac's spec's

aluminium framed joineryselected powdercoat finish

colorbond metal fascia & gutter

colorbond metal sheet roofingfixed to manufacturers spec's.

cj cj

hardies "linea" cladding fixedper manufacturers spec's.

TERRACE PITCHING

2550

PITCHING HEIGHT

2740

colorbond metal fascia & gutter

hardies "linea" cladding fixedper manufacturers spec's.

colorbond metal sheet roofingfixed to manufacturers spec's.

texture render finish to 100mm hebelpanels fixed as per manufac's spec's

aluminium framed joineryselected powdercoat finish

PITCHING HEIGHT

2740

hardies "linea" cladding fixedper manufacturers spec's.

texture render finish to 100mm hebelpanels fixed as per manufac's spec's

colorbond metal fascia & gutter

cj

aluminium framed joineryselected powdercoat finish

selected remotepanel lift door.

selected timber framed entry door with fixed glass side light

cj 450

2200

BED 2 PITCHING

2550

PITCHING HEIGHT

2740

aluminium framed joineryselected powdercoat finish

colorbond metal fascia & gutter

colorbond metal sheet roofingfixed to manufacturers spec's.

cj

350x350 Hebel clad column galv.steel post & framing to engineersdetail texture render finish

hardies "linea" cladding fixedper manufacturers spec's.

REFERENCE #SHEET #

SCALE DATE DRAWNCLIENT PROJECT

REV # DATE

QBSA Lisc No. 62679

22 Mallawa Drive

Palm Beach QLD 4211

ph 0413 801 226

email

[email protected] ALL DIMENSIONS BEFORE COMMENCEMENT OF

CONSTRUCTION. ALL DESIGNS ARE COPYRIGHT & REMAIN THE

PROPERTY OF PROJECT PLANNING GROUP & MARK HUDSON DESIGNS

1 : 100 JAN-18PROPOSED RESIDENCESITE 88 NATURES EDGE25 OWEN CREEK ROADFOREST GLEN

S04.07

VPPROPCORP (QLD) Pty Ltd

88.C1-MDFD

B

C

05/06/2018 - window revision

11/02/2018 - client revisions

19/02/2018 - client revisions

1 : 100 @ A3

SSSS south elevation1 : 100 @ A3

WWWW west elevation

1 : 100 @ A3

NNNN north elevation1 : 100 @ A3

EEEE east elevation

Page 6: PROPOSED RESIDENCE AT NATURES EDGEtrade.ausmargroup.com.au/wp-content/uploads/2018/06/LOT-88-NA… · panel lift door. selected timber framed entry door with fixed glass side light

"KEEP FACE OF SLAB LEVEL"

F A L L

50mm recessto shower

fd

100mm x 45mm deep rebate

100m

m x 45m

m deep rebate

100mm x 45mm deep rebate

provide clean edge tofooting and slab face

NOTE

- ALLOW FOR 20mm REBATE TO ALL SLIDING DOOR POSITIONS & ENTRY DOOR.

- SLAB TO BE FINISHED FOR DIRECT STICK TILES WHERE NOTED. REFER TO FLOOR PLAN

50mm step

150m

m step

150mm step

100mm x 45mm deep rebate

50mm recessto shower

F A L L

F A L L

50mm recessto shower

50mm step

50mm step

100m

m x 45m

m

deep rebate

100mm x 45mm deep rebate

150mm step

50mm step

50mm step

290

680 4800 680

1350

6140

2540

4030

1000

1200 17270 1170

7130 5400 4940 2170

5710 1710 450 3490 2040 2120 1020 930 2170

6160 1260

150

2800

2970

1130

950

1720

4040

300

1000

15060 23

232

17407

3400

4470

8240

1580

7440

1100

11280 1000 1120

5890

950

170

12930 1350 170

600 4200 600

465

1810

125

365 1510 215

365 1510 215

REFERENCE #SHEET #

SCALE DATE DRAWNCLIENT PROJECT

REV # DATE

QBSA Lisc No. 62679

22 Mallawa Drive

Palm Beach QLD 4211

ph 0413 801 226

email

[email protected] ALL DIMENSIONS BEFORE COMMENCEMENT OF

CONSTRUCTION. ALL DESIGNS ARE COPYRIGHT & REMAIN THE

PROPERTY OF PROJECT PLANNING GROUP & MARK HUDSON DESIGNS

1 : 100 JAN-18PROPOSED RESIDENCESITE 88 NATURES EDGE25 OWEN CREEK ROADFOREST GLEN

S05.07

VPPROPCORP (QLD) Pty Ltd

88.C1-MDFD

B

C

05/06/2018 - window revision

11/02/2018 - client revisions

19/02/2018 - client revisions

1 : 100 @ A3

SSSS slab setout

Page 7: PROPOSED RESIDENCE AT NATURES EDGEtrade.ausmargroup.com.au/wp-content/uploads/2018/06/LOT-88-NA… · panel lift door. selected timber framed entry door with fixed glass side light

TELEVISION OUTLET

TELEPHONE OUTLET

FLURO TUBE LIGHT

WALL LIGHT

SWITCH POSITION

EXHAUST FAN/HEATER/LIGHT

DOWNLIGHT

METER BOARD

legend

EXHAUST

JUNCTION BOXJB

AIRCON UNIT

GPO

CEILING FAN

S SPOT LIGHT & SENSOR )

ISOLATOR

F FOXTEL PROVISIONS

BUNKER LIGHT

FEATURE LIGHT

NBN NBN BOX

EXTERNAL DOWNLIGHT

PHOTOELECTRIC SMOKE ALARMSTO BE POSITIONED IN BUILDING TO

COMPLY WITH BCA CLASS 1-10 PART 3.7.2 AND WITH A.S.3786

GAS POINT

A/C

INT INTERCOM

UNDER BENCH

FOR WM/DR

E

A/C

2W

2W

2W

2W

2W

2W

F

NBN

A/C UNIT LOCATION

TBD BY CONTRACTOR A/C

SWITCHED

ON DOOR

REFERENCE #SHEET #

SCALE DATE DRAWNCLIENT PROJECT

REV # DATE

QBSA Lisc No. 62679

22 Mallawa Drive

Palm Beach QLD 4211

ph 0413 801 226

email

[email protected] ALL DIMENSIONS BEFORE COMMENCEMENT OF

CONSTRUCTION. ALL DESIGNS ARE COPYRIGHT & REMAIN THE

PROPERTY OF PROJECT PLANNING GROUP & MARK HUDSON DESIGNS

1 : 100 JAN-18PROPOSED RESIDENCESITE 88 NATURES EDGE25 OWEN CREEK ROADFOREST GLEN

S06.07

VPPROPCORP (QLD) Pty Ltd

88.C1-MDFD

B

C

05/06/2018 - window revision

11/02/2018 - client revisions

19/02/2018 - client revisions

1 : 100 @ A3

EEEE electrical plan

Page 8: PROPOSED RESIDENCE AT NATURES EDGEtrade.ausmargroup.com.au/wp-content/uploads/2018/06/LOT-88-NA… · panel lift door. selected timber framed entry door with fixed glass side light

SILL DETAIL

OPTION 1 - SIDE & REAR

WALLS ONLY

HEADER DETAIL

ROOF EAVES

DETAIL

GARAGE HEAD

DETAIL

GARAGE DOOR

JAMB DETAIL

OPTION 1

OPTION 2

SILL DETAIL

OPTION 2 - STREET FACING

WALLS ONLY

TYPICAL SLAB/PATIO/

PORCH PATH SECTION

TYPICAL GARAGE SLAB/

DRIVEWAY SECTION

TYPICAL SLAB

SECTION100

75

25

4510

5

290

REFERENCE #SHEET #

SCALE DATE DRAWNCLIENT PROJECT

REV # DATE

QBSA Lisc No. 62679

22 Mallawa Drive

Palm Beach QLD 4211

ph 0413 801 226

email

[email protected] ALL DIMENSIONS BEFORE COMMENCEMENT OF

CONSTRUCTION. ALL DESIGNS ARE COPYRIGHT & REMAIN THE

PROPERTY OF PROJECT PLANNING GROUP & MARK HUDSON DESIGNS

SHOWN JAN-18PROPOSED RESIDENCESITE 88 NATURES EDGE25 OWEN CREEK ROADFOREST GLEN

S07.07

VPPROPCORP (QLD) Pty Ltd

88.C1-MDFD

B

C

05/06/2018 - window revision

11/02/2018 - client revisions

19/02/2018 - client revisions