15
PSTN Home Alarm System User Manual Model: PST-TEL99E Please read this user guide carefully before operation and installation.

PSTN Home Alarm System - Alarmas Zoom PROFESSIONAL SECURITY TECHNOLOGY Co., ... SHENZHEN PROFESSIONAL SECURITY TECHNOLOGY Co., LIMITED - 9 - Install PIR ... office building, school,

  • Upload
    dinhthu

  • View
    217

  • Download
    3

Embed Size (px)

Citation preview

PSTN Home Alarm System

User Manual

Model: PST-TEL99E

Please read this user guide carefully before operation and installation.

File Name: PST-TEL99E User Manual File Version: PST-V1308002-001

SHENZHEN PROFESSIONAL SECURITY TECHNOLOGY Co., LIMITED

- 2 -

Contents 1. Product Overview........................................................................................................ - 3 - 2. Main Function & Features........................................................................................... - 3 - 3. For Your Safety ........................................................................................................... - 4 - 4. TEL99E Characteristics .............................................................................................. - 4 - 5. Getting Started............................................................................................................ - 5 -

5.1 Standard Package List........................................................................................ - 5 - 5.2 View.................................................................................................................... - 5 - 5.3 Functional Parts.................................................................................................. - 6 - 5.4 Connecting and Installation ................................................................................ - 7 -

6. Operation steps by keyboard setting......................................................................... - 10 - 6.1 Open/Close password protection function, Change user’s password......... - 10 - 6.2 Adjust the volume of alarm siren ................................................................ - 10 - 6.3 Set up alarming telephone numbers............................................................- 11 - 6.4 Delete telephone numbers ..........................................................................- 11 - 6.5 Set up siren sound time when system alarming ..........................................- 11 - 6.6 Set up alarm delay ......................................................................................- 11 - 6.7 Set ARMING delay ......................................................................................- 11 - 6.8 Set remote telephone ringing times............................................................ - 12 - 6.9 Set siren sound when using the remote control.......................................... - 12 - 6.10 Set buzzer sound on/off............................................................................ - 12 - 6.11 Learning and delete detectors .................................................................. - 12 - 6.12 Set up mode of zones .............................................................................. - 12 - 6.13 Inquiry alarm defense area....................................................................... - 13 - 6.14 Telephone line anti-cut function ................................................................ - 13 -

7. Remote Controller (Key fob) Description ............................................ ……- 13 - 7.1 Set up Arm........................................................................................................ - 13 - 7.2 Set up Disarm................................................................................................... - 13 - 7.3 Emergency Alarm ............................................................................................. - 13 - 7.4 Intelligent Arm................................................................................................... - 13 -

8. Remote Control the system ...................................................................................... - 13 - 9. Handing Incoming Alarm Phone Calls....................................................................... - 14 - 10. Reset Factory Settings ........................................................................................... - 14 - 11. Copyright and Disclaimer........................................................................................ - 14 - 12. Operation Command List........................................................................................ - 15 -

File Name: PST-TEL99E User Manual File Version: PST-V1308002-001

SHENZHEN PROFESSIONAL SECURITY TECHNOLOGY Co., LIMITED

- 3 -

1. Product Overview

TEL99E is a PSTN intelligent home alarm system. This LED display alarm system is equipped with PSTN technologies and suitable for both home and commercial use. It uses the PSTN landline networks with intelligent alarm system. It is a choice of stability, reliability, security, and user friendliness. Features are very practical, cost-effective, completed configuration and ease of use. This LED display alarm can integrate with a lot of alarm accessories including door sensor, smoke detectors, gas detectors, emergency buttons and other accessories to build a powerful security setup. It has been widely used in homes, factories, schools, shops, convenience stores, financial and banking workplace, community centre and residential area to provide protection to valuable assets.

2. Main Functions & Features

TEL99E has the following main functions and features: 99 Wireless Zones with LED display PSTN telephone line working ways LED indicator Arm/Disarm/Stay arm/Alarm/Setting Password protection function 5 groups of call phone number and SMS number, 1 group of emergency phone number and

SMS number 0-99secs. delay alarm setting 0-99secs. delay arm setting 0-30mins. Siren ringing time setting Ringing times setting Stay intelligent arm Multi-Zones Triggered Mode (2 or more than 2 zones) Repeat triggered alarm function(sensor alarm after triggered twice) Telephone line anti-cut function Remote control the TEL99E stop the siren sound or start the siren sound Remote Monitoring/Arm/Disarm Reset factory setting

File Name: PST-TEL99E User Manual File Version: PST-V1308002-001

SHENZHEN PROFESSIONAL SECURITY TECHNOLOGY Co., LIMITED

- 4 -

3. For Your Safety

Read these simple guidelines. Not following them may be dangerous or illegal. Proper Connection When connecting with other device, read carefully its manual

so as to carry out correct installation. Do not connect it to other incompatible devices.

Qualified Accessories Use original parts and peripheral equipments to avoid damage to TEL99E.

Water Resistance TEL99E is not water resistant. Keep it dry. Install it inside the house

Confidential Phone Number

For safety reason, do not tell other people the telephone number of your TEL99E without taking precautions of security settings.

4. TEL99E Characteristics

Items Specification Power Supply DC12V / 1A Backup Battery Ni-Hi AAA*6 DC7.4V Standby current <35 mA Alarm current <450 mA Wireless frequency 433MHz Support wireless sensors

EV1527/300K 2262/1.5-4.7M

Wireless distance 100m open LED screen display time/Arm/Disarm/Stay arm/Alarm/Setting Operating temperature

-10° to 50° C

Humidity 5% to 95% Non-condensing Dimension 33*25*7.5cm Weight 1.2Kg

File Name: PST-TEL99E User Manual File Version: PST-V1308002-001

SHENZHEN PROFESSIONAL SECURITY TECHNOLOGY Co., LIMITED

- 5 -

5. Getting Started

This section will describe how to set up your TEL99E.

5.1 Standard Package List

TEL99E is supplied in a box which includes:

5.2 View

Front View Side View Back View

File Name: PST-TEL99E User Manual File Version: PST-V1308002-001

SHENZHEN PROFESSIONAL SECURITY TECHNOLOGY Co., LIMITED

- 6 -

5.3 Functional Parts

LED screen display SF ARM BF INTELLIGENT ARM CF Disarm 99 Emergency alarm F1 Telephone line disconnect F3 No add sensor 1-98 Alarm zone display LED indicator POWER Power LED light, power supply working normal ALARM Alarm LED light, alarm system alarm

SET SET LED light, the alarm system into setting status

PHONE PHONE LED light, access telephone line work normal

Microphone Personal remote monitoring Function keyboard ARMING ARMING LED light, the alarm system system into

arm status INTELLIGENT INTELLIGENT LED light, the alarm system

system into intelligent status DISARMING DISARMING LED light, the alarm system system

into disarm status ALARM ALARM LED light, the alarm system system into

alarm status Digital Keyboard Setting alarm system system function

File Name: PST-TEL99E User Manual File Version: PST-V1308002-001

SHENZHEN PROFESSIONAL SECURITY TECHNOLOGY Co., LIMITED

- 7 -

Antenna Wireless antenna

LINE1 Connect LINE1 to telephone uses telephone wire of standard package list

LINE2 Connect LINE2 to telephone out line

POWER Connect DC12V adapter uses power adapter of standard package list

SIREN Connect siren uses siren of standard package listON OFF Power on battery or power off battery

5.4 Install accessories Install the Door sensor The door/window magnetic sensor includes two parts. The sensor will send the wireless signal to main unit immediately when the two parts depart more than 10-30mm. The picture of the installation is as follows,

File Name: PST-TEL99E User Manual File Version: PST-V1308002-001

SHENZHEN PROFESSIONAL SECURITY TECHNOLOGY Co., LIMITED

- 8 -

In some circumstances the wired & wireless Infrared Fence detector is more appropriate than magnetic sensors. i.e. veranda, picture window balcony, boundary wall.

wireless glass break detector can also be used for window (see below)

The sensitivity is adjustable Wireless scroll steel door magnetic sensor for scrolling steel door, Installation: Please see below picture It is triggered when the two parts are separated to 3cm - 5cm.

File Name: PST-TEL99E User Manual File Version: PST-V1308002-001

SHENZHEN PROFESSIONAL SECURITY TECHNOLOGY Co., LIMITED

- 9 -

Install PIR motion sensor PIR refers to passive Infra-red. A Passive Infra-red Sensor is an electronic device that detects the motion or movement of some person or animal by sensing the heat emitted from the body. Installation:

The installation of wireless ceiling PIR sensor

Install smoke/gas detectors a) Wireless smoke detector This smoke detector detects smoke by a couple of infrared diodes, which is suitable for detecting the smoke in house, shop, hotel, restaurant, office building, school, bank, library and storehouse etc. b) Wireless gas detector The product is ceiling mounted gas detector with high stability. It is used for detecting leaking gas and suitable for the safety of residential house, villas, hotels, boarding house etc. Detecting the gas heavier than air: installation height from floor: 0.3m ~ 1.0m, semi-diameter to gas sources: < 1.5m; detecting the gas lighter than air: installation height from ceiling 0.3m ~ 1.0m, semi-diameter to gas sources: < 1.5m.

File Name: PST-TEL99E User Manual File Version: PST-V1308002-001

SHENZHEN PROFESSIONAL SECURITY TECHNOLOGY Co., LIMITED

- 10 -

6. Operation steps by keyboard setting

Note: When setting by the keyboard, all the settings can be carried out under the undefended

situation with a long ring for all the proper operations while two short sounds for wrong settings. 6.1 Open/Close password protection function, Change user’s password Command: *11* Description: open password protection function Note: Open this function; you need first input password before operation keyboard, the factory password is: 0000, input password: *0000* Command: *10* Description: close password protection function Note: close this function; you no need input password before operation keyboard Command: *7xxxx(4 numbers new password )xxxx(4 numbers new password )* Description: modify passwords 6.2 Adjust the volume of alarm siren Command: #00# Description: silent alarm, the siren no sound when the system alarm Command: #01# Description: the siren sound when the system alarm 6.3 Set up alarming telephone numbers Command: #1xxxxxxxxxxxxx(telephone number)# Description: “1” means set the first group telephone number, you can receive SMS and call when system alarm. Command: #2xxxxxxxxxxxxx(telephone number)# Description: “2” means set the second group telephone number, you can receive SMS and call when

Open or close manipulator /Test button Power LED (green)

File Name: PST-TEL99E User Manual File Version: PST-V1308002-001

SHENZHEN PROFESSIONAL SECURITY TECHNOLOGY Co., LIMITED

- 11 -

system alarm. Command: #3xxxxxxxxxxxxx(telephone number)# Description: “3” means set the third group telephone number, you can receive SMS and call when system alarm. Command: #4xxxxxxxxxxxxx(telephone number)# Description: “4” means set the forth group telephone number, you can receive SMS and call when system alarm. Command: #5xxxxxxxxxxxxx(telephone number)# Description: “5” means set the fifth group telephone number, you can receive SMS and call when system alarm. Command: #6xxxxxxxxxxxxx(telephone number)# Description: “6” means set the sixth group telephone number, you can receive SMS and call when system alarm. This is emergency phone numbers 6.4 Delete telephone numbers Command: #1#; Description: delete the first group telephone number. Command: #2#; Description: delete the second group telephone number. Command: #3#; Description: delete the third group telephone number. Command: #4#; Description: delete the forth group telephone number. Command: #5#; Description: delete the fifth group telephone number. Command: #6#; Description: delete the sixth group emergency telephone number. 6.5 Set up siren sound time when system alarming Command: #9xx(00-30minutes)# Description: e.g: #95#, the siren will sound 5 minutes when the system alarm. 6.6 Set up alarm delay Command: #7xx(00-99seconds)# Description: e.g: #730#, the system will alarm after sensor is triggered 30 seconds. 6.7 Set ARMING delay Command: *4xx(00-99seconds)* Description: e.g: *430*, the system will auto ARMING after press ARM key 30 seconds. 6.8 Set remote telephone ringing times Command: *6x(0-9times)* Description: e.g: *63*, if will automatically get through after ringing 3 times, *60*, means no ringing times.

6.9 Set siren sound when using the remote control Command: *21* Description: The siren have reminder sound when you press remote control Command: *20*

File Name: PST-TEL99E User Manual File Version: PST-V1308002-001

SHENZHEN PROFESSIONAL SECURITY TECHNOLOGY Co., LIMITED

- 12 -

Description: The siren off sound when you press remote control, only have buzzer sound. on the remote control to turn on the siren sound. 6.10 Set buzzer sound on/off Command: *99* Description: Off the buzzer sound. Command: *98* Description: Open the buzzer sound. 6.11 Learning and delete detectors Command: *0* Description: Learning Remote controller: After you press *0* on the alarm panel keyboard, then press any button of the remote controller within 10 seconds. A long “Bi” sound means successfully. Command: *01* Description: Learning detectors: After you press *01* on the alarm panel keyboard, then trigger the detector within 10 seconds. A long “Bi” sound means successfully. Command: *8xx(00-99zones number)* Description: Learning detector to the designated zones number, e.g: *816*, means learning a detector to zone 16. Command: *02* Description: Delete all of the remote controllers Command: #8996# Description: Delete all detectors. 6.12 Set up mode of zones Command: #8xxA# Description: “xx” means 00-99 zones; “A” means mode of zones (0-8), 0: bypass mode, the zone will not working in anytime 1: common mode, the zone will alarm when system ARMING 2: intelligent mode, the zone will not working when system INTELLIGENT ARMING 3. Emergency mode, the zone will working in anytime, it can alarm when system DISARMING 4. Multi-Zones Triggered Mode: You must setup 2 or more than 2 zones for Multi-zones(for example, 5th zone and 10th zone). For multi-zones triggered mode, only all the detectors you have registered for these zones you have setup for multi-zones are triggered within 30s. the alarm panel will alarm. 5. delay-alarm mode, the system not immediately alarm after set up delay alarm mode. 6. Repeat triggered mode, when the detector is triggered once, the system will not alarm immediately, only when it is triggered again within 30s after the first trigger, the system will alarm. 7. Doorbell mode, the system will “ding dong” when detector be triggered.

File Name: PST-TEL99E User Manual File Version: PST-V1308002-001

SHENZHEN PROFESSIONAL SECURITY TECHNOLOGY Co., LIMITED

- 13 -

6.13 Inquiry alarm defense area Command: x(0-9) Description: Directly press 0~9 to inquiry the latest 10 alarm events and display alarm defense area (0 means the latest one). 6.14 Telephone line anti-cut function Command: *51* Description: the system will alarm when telephone lines disconnect or failure Command: *50* Description: the system will not detect telephone lines disconnection or fault. 7. Remote Controller (Key fob) Description

7.1. Set up Arm

Press “ ”button on the remote controller, and the LED display “SF”, means system “Armed”.

7.2 Set up Disarm

Press “ ” button on the remote controller, and the LED display “CF”, means system

“Disarmed”.

7.3. Emergency Alarm

Press “ ”button on the remote controller for emergency help, And the LED display “99”.

Press“ ”button on the remote controller one time is silent alarm, while press “ ”button twice or long

time the siren will sound.

7.4. Intelligent Arm

Press “ ” button on the remote controller and the LED display “bF”, means system “Intelligent

Armed”.

8. Remote Control the system:

You can use any telephone to dial the numbers of the system and it will put on automatically

get through after system detecting the ring times you have been setup. When you hear the

beep, input passwords (two sounds when the password is wrong, if the password input

wrongly 3 times or no any operations within 20 seconds the phone will hang up automatically)

and if it is correct, you can have remote control of the system, press # after accomplish all

operations, then you can implement other operations and hang up telephone.

Press “1” to monitor (Press “1” again for monitor 20 seconds more.)

Press “2” to start the siren

File Name: PST-TEL99E User Manual File Version: PST-V1308002-001

SHENZHEN PROFESSIONAL SECURITY TECHNOLOGY Co., LIMITED

- 14 -

Press “3” to stop the siren

Press “4” to arm

Press “5” to disarm

Press “#” to affirm and hang up

9. Handing Incoming Alarm Phone Calls

When sensors are triggered or emergency help, the alarm panel will dial up the setup telephone

numbers automatically and give alarm rings based on settings. If the host’s phone is in use or not

able to connect, the system will dial next alarm phone, until it is dialed and hosts confirm. It will play

records after receiving alarm phone and the operation methods are similar to remote setup.

10. Reset Factory Settings Command:*80000* Description: 0000 is default password (All settings will be cleared except all the registered sensors) 11. Copyright and Disclaimer Copyright © 2013 PST. All rights reserved. The user manual may be changed without prior notification. This user manual, or any part thereof, may not be reproduced for any purpose whatsoever without the written authorization of PST, or transmitted in any form, either electronically or mechanically, including photocopying and recording. In no event shall PST be liable for direct, indirect, special, incidental, or consequential damages (including but not limited to economic loss, personal injury, and loss of asset and property) arising out of the use or inability or illegality to use the product or documentation. If you encounter any problems when using our products, and cannot solve them by yourself, please contact our technical support team by writing an E-Mail to [email protected]. We will be pleased to help you.

File Name: PST-TEL99E User Manual File Version: PST-V1308002-001

SHENZHEN PROFESSIONAL SECURITY TECHNOLOGY Co., LIMITED

- 15 -

12. Operation Command List

Learning remote controller *0*

Delete all of the remote controller *02*

Learning detector *01*

Learning detector to appoint zone *8XX* 00-99 zones

Add or

Delete

sensor

Delete all of the detector #8996#

Set up alarm telephone numbers

#1XXXXXXXXXX#

#2XXXXXXXXXX#

#3XXXXXXXXXX#

#4XXXXXXXXXX#

#5XXXXXXXXXX#

#6XXXXXXXXXX#

XX….X

telephone

number

Set up

telehone

numbers

Delete the telephone numbers #1# #2# #3#

#4# #5# #6#

Set up alarm delay time #7XX# 0-99seconds

Set up siren sound time #9XX# 0-30 minutes

Set up Arm delay time *4XX* 0-99 seconds

Set remote telephone ringing times *6X* 0-9 times

Set up siren sound for the remote

control

*21*

*20*

21 On

20 Off

Set up the buzzer sound *99*

*98*

99 Off

98 On

Set up volume of alarm siren #00#

#01#

00 No sound

01 Have sound

Function

Telephone line anti-cut function *51*

*50*

51 On

50 Off

Mode Set up mode of zones

#8XX0# Bypass mode

#8XX1# Common mode

#8XX2# Intelligent mode

#8XX3# Emergency mode

#8XX4# Multi-Zones Triggered Mode

#8XX5# Delay-alarm mode

#8XX7# Repeat triggered mode

XX:00-99 zones

Open/Close password protection

function

*11*

*10*

11 On

10 Off

Input password *0000*

Modify password *+new password+new password*

Password

Reset Factory Settings *80000*