LA-U R- a Approved for public release; distribufion is unlimited. Title: Author(@ Submitted to Los Alamos PROPOSED EXPERIMENT TO MEASURE THE NEUTRON SPIN-ELECTRON ANGULAR CORRELATION IN POLARIZED NEUTRON BETA DECAY WITH ULTRA-COLD NEUTRONS Susan J. Seestrom, P-23 Conference Proceedings: 6th International Seminar on Interaction of Neutrons with Nuclei Dubna, Russia May 13-16, 1998 NATIONAL LABORATORY Los Alamos National Laboratory, an affirmative actiodequal opportunity employer, is operated by the University of California for the US. Department of Energy under contract W-7405-ENG-36. By acceptance of this article, the publisher recognizes that the US. Government retains a nonexclusive, royalty-free license to publish or reproduce the published form of this contribution, or to allow others to do so, for U.S. Government purposes. Los Alamos National Laboratory requests that the publisher identify this article as work performed under the auspices of the US. Department of Energy. The Los Alamos National Laboratory strongly supports academic freedom and a researcher's right to publish: as an institution, however, the Laboratory does not endorse the viewpoint of a publication or guarantee its technical correctness. Form 836 (10/96)

public is unlimited. Title: PROPOSED EXPERIMENT …/67531/metadc704837/m2/1/high... · measurements of superallowed 0' + 0' nuclear beta decay and from the value ... A longitudinal

Embed Size (px)

Citation preview

LA-U R- a

Approved for public release; distribufion is unlimited.

Title:

Author(@

Submitted to

Los Alamos

PROPOSED EXPERIMENT TO MEASURE THE NEUTRON SPIN-ELECTRON ANGULAR CORRELATION IN POLARIZED NEUTRON BETA DECAY WITH ULTRA-COLD NEUTRONS

Susan J. Seestrom, P-23

Conference Proceedings: 6th International Seminar on Interaction of Neutrons with Nuclei Dubna, Russia May 13-16, 1998

N A T I O N A L L A B O R A T O R Y Los Alamos National Laboratory, an affirmative actiodequal opportunity employer, is operated by the University of California for the US. Department of Energy under contract W-7405-ENG-36. By acceptance of this article, the publisher recognizes that the US. Government retains a nonexclusive, royalty-free license to publish or reproduce the published form of this contribution, or to allow others to do so, for U.S. Government purposes. Los Alamos National Laboratory requests that the publisher identify this article as work performed under the auspices of the US. Department of Energy. The Los Alamos National Laboratory strongly supports academic freedom and a researcher's right to publish: as an institution, however, the Laboratory does not endorse the viewpoint of a publication or guarantee its technical correctness. Form 836 (10/96)

DISCLAIMER

Thii report was prepared as an account of work sponsored by an agency of the United States Government. Neither the United States Government nor any agency thereof. nor any of their employees, makes any warranty, express or implied. or assumes any Iegal liability or responsibility for the accuracy, completeness, or use- fulness of any information, apparatus, product, or process disclosed, or represents that its use would not infringe privately owned rights. Reference herein to any spe- cific commercial product, process, or seMce by trade name, trademark, manufac- turer, or otherwise docs not necessarily constitute or imply its endorsement. m m - mendation. or favoring by the United States Government or any agency thereof. The views and opinions of authors expmsed herein do not necessarily state or reficct those of the United States Government or any agency thereof.

DISCLAIMER

Portions of this document may be illegible in electronic image products. Images are produced from the best available original document.

.

PROPOSED EXPERIMENT TO MEASURE THE NEUTRON SPIN - ELECTRON ANGULAR CORRELATION IN POLARIZED

NEUTRON BETA DECAY WITH ULTRA-COLD NEUTRONS

S. J. Seestrom, for the UCN A Collaborationt Los Alamos National Labordory

Los Alamos, NM 87545

1 Introduction

The Standard Model, which describes the structure of the strong, electromagnetic, and weak forces, has been very successful in describing a wide range of experimental data. Within the standard model the electroweak interaction is given by the Weinberg-Salam-Glashow (W-S- G) model which specifies a purely left-handed (V-A) interaction. This left-handed structure reproduces the observed state in nature, but the Standard Model does not provide any underlying reason for this structure. It is assumed that Standard Model is only part of a larger model. Various extensions of the model, such as Grand Unified field Theories (GUTS), SUperSYmmetric (SUSY) theories, and String Theories, attempt to unify the weak nuclear, electromagnetic, and strong nuclear forces in a single, comprehensive theory. These theories predict that a range of new phenomena beyond the Standard Model should exist, including proton decay, non zero neutrino masses and mixing, right-handed currents, and new particles. In the past two decades, much effort has been expended in searching for new physics beyond the Standard Model. One area in which the Standard Model can be probed is neutron beta decay. In particular, measurements of angular correlations in neutron beta decay can place constraints on the existence of right-handed currents, the presence of scalar and tensor terms in the weak interaction, and for evidence of Time Reversal Violation, which is expected from the observed violation of CP invariance in kaon decay.

A measurement of A, the correlation between the neutron spin and the direction of emission of the electron in neutron decay, can be combined with the neutron lifetime to determine the fundamental vector and axial vector weak coupling constants GA and Gv. The value of Gv determined from neutron beta decay can also be compared with the value determined from measurements of superallowed 0' + 0' nuclear beta decay and from the value determined by requiring that the Cabibbo-Kobayashi-Maskawi (CKM) matrix (which describes the mixing between quarks) be unitary. This provides a sensitive means to search for Physics beyond the Standard Model.

In recent years four measurements of A have been carried out using cold neutron beams at reactors. These measurements quoted combined statistical and systematic uncertainty of about 1 % in the determination of A. The three measurements preceding the most recent Perkeo 11 are in reasonable agreement with each other, but disagree with both the 0' + 0' beta decay and CKM unitarity.'-' Perkeo If is in disagreement with the average of the previous three. The discrepancy between the various neutron measurements is likely due to the existence of systematic problems. In order to understand the origin of the discrepancies, it is obviously essential to carry out new measurements with very different systematic effects than those in the reactor experiments. It is also equally important to improve the accuracy of these experiments in order to search for new

physics with increased sensitivity. The goal of our experimental program is to address these issues with a measurement of the A correlation with substantially improved accuracy.

A measurement of the A correlation using Ultra-Cold Neutrons (UCN) provides significant advantages over reactor beam experiments. As UCN can be transported through bent guide tubes, it is possible to place the experiment at a position distant (of order 10 m) from any neutron beam. In addition, at a Short-Pulse Spallation Source (SPSS), one can suppress backgrounds significantly by using timing information so that data are excluded during the period just after the proton pulse strikes the spallation target. It is also possible to 100% polarize UCN by passage through a magnetic field gradient with a maximum field of about 5 Tesla. Depolarization effects are calculated to be very small ( c 3 x thus a UCN source with essentially 100% polarization can be constructed. The main disadvantage of UCN is that rates obtainable are much lower than can be obtained in experiments using cold neutron beams.

2 UCN Measurement of A

The essential features of the experiment are shown in Figure 1. The UCN are stored (or rather flow through) a long, diffuse, windowless bottle. A longitudinal magnet field serves to maintain the neutron spin and to guide the beta decay electrons out to the beta spectrometers located at the ends of the bottle. Magnet field expansion is used to reduce electron backscatter. The transverse location of the decaying neutron is determined using a thin wire chamber located in front of the plastic scintillator used to measure the electron energy.

A diamond-coated UCN guide tube will transport UCN from the rotor source to the A correlation spectrometer. The UCN will be 100% polarized by passage through a 5 T superconducting solenoid. The UCN will then pass through an Adiabatic Fast Passage (AFP) resonator that will allow rapid spin flipping of the UCN. In our geometry, the adiabatic condition for spin flipping should be well satisfied and under less favorable conditions, experiments at SLAC achieved A F P spin-flip efficiencies of > 99.9%. The UCN will then be fed to the center of the A correlation spectrometer, as shown in Fig. 1.

The spectrometer consists of a 6-m long, 10 cm diameter UCN open-ended bottle that defines a decay volume for the UCN. A suitable wall material is diamond film, made from deuterated precursors, deposited onto the inner surface of a quartz tube. Such a surface has a rather high effective potential (with a cutoff velocity of 7.6 d s ) and a loss rate corresponding to a lifetime of about 50 seconds at room temperature. Furthermore, the depolarization time for such a surface would be extremely long. Data from the ILL Electric Dipole Moment (EDM) experiment already provide a lower limit of loo0 s for the spin relaxation time.

A highly-uniform ( e lo” variation) strong (0.5 T) magnetic field is generated along the axis of the UCN trap by a conventional solenoid. At the ends of the bottle, the magnetic field is expanded in the region before the detector. The strong magnetic field in the solenoid is used to determine the neutron spin direction and is used to guide the betas from neutron decay in the bottle to the detectors, as shown in Fig. 2. The betas are detected in a Multi-Wire Proportional Chamber (MWPC) - scintillator system at the ends of the Spectrometer in the expanded field region. This detector system allows both position information from the multi-wire proportional counters (MWPC), total energy information (from the scintillator), and some information on the pitch angle of the electron (from the dE/dx measurement in the MWPC). The pitch angle of the betas

decreases as the beta moves from the high field to the low field region, which reduces the backscattering amplitude of electrons from the MWPC windows and the scintillator, thus substantially reducing one of the largest systematic effects in measuring the A correlation. This geometry strongly suppresses backscattering effects by mirroring the backscattered betas back into the detector. The spectrometer is shielded against both neutron and gamma backgrounds

Full calibration of the energy resolution function of the spectrometer is of paramount importance for an A correlation experiment. In the previous reactor ex eriments, this has been done using thin film conversion line sources such as '09Cd and 20%i. While we will certainly calibrate the spectrometer using this type of source introduced at the center of the spectrometer, it would be advantageous to have a source which filled the spectrometer active volume in the same manner as the UCN. At least one such a source does exist - several isotopes of Xe decay by internal conversion or by beta decay with energies up to a few hundred keV. In addition to filling the UCN bottle region fully, such a source is massless and thus does not have the scattering tails typical of conversion line sources deposited on thin films. The Xe isotopes can be easily produced in mCi quantities in one day of irradiation in a thermal reactor. The lifetimes of the isotopes are relatively short (a few days to a few weeks), but enough of the Xe isotopes can be produced in a single irradiation to provide a useful source for 1 - 2 months.

There are two features of the A experiment as designed that are central to achieving a high signal-to-background ratio (of order 1 0 0 / 1 with a threshold of 100 keV or lower): the use of a strong magnetic guide field that allows 4n: collection efficiency of the betas in a relatively small detector, and the use of a coincidence requirement between the proportional counter and scintillator in the spectrometer.

The UCN exiting the decay tube are monitored in an array of UCN detectors, are transported down a diamond-coated UCN guide to a 3He detector, or are captured on 6LiH surfaces in the region between the decay tube and the detectors. Thus, the UCN are effectively pumped away at the ends of the decay tube, thereby strongly reducing the number of neutron decays in the field expansion region. This arrangement also provides the means to monitor both the total number of UCN exiting the bottle as well as the number of UCN in the field expansion region.

We will be able to measure the depolarization of the UCN in situ by using the 5 T superconducting solenoid as both a polarizer and an analyzer. This is done by polarizing the UCN when filling the UCN bottle, closing off the bottle for some time, then emptying the bottle first through the 5 T solenoid (now acting as an analyzer) and finally counting any wrong spin state neutrons left in the UCN bottle. By also installing UCN valves at the inlet of the polarizer and between the polarizer and the AFP unit, one can also search for depolarization effects due to multiple passes of the UCN through the AFP and polarizer.

We have carried out Monte Carlo calculations of the holding time integrated UCN density of UCN in the spectrometer, resulting in a bottle lifetime of about 5 seconds. Our count rate estimates are based on measurements made with the rotor source, and on expected improvements in the facility and the rotor. We typically detected 650 UCN/s at

the end of a 3-m long, 8 cm diameter guide. The maximum rate that we expect to achieve in the experiment is a total decay rate in the bottle of 33.4 Hz. In order to achieve a given statistical accuracy OA, we expect that OA = 2.7 / dN. After correcting for live time, detection efficiency, fiducial volume cut, and timing cut efficiency we estimate a counting rate after all cuts of 6-18 Hz. We expect to acquire statistical data for 100-300 days, during which time we will observe 1.6 x lo8 decays. Thus, we can achieve a statistical accuracy of <TA /A = 1.9 x 10" (<TA = 2.1 x We note the important fact that the signal to background will be 68/1.

A central issue in accurately determining the beta-asymmetry is the systematic uncertainties in the measurement. As noted above, UCN offer significant reductions in the major systematic effects in a measurement of the A correlation. The systematic uncertainties can be broadly divided into three categories: those concerning knowledge of the A) neutron spin-dependent effects, B) electron collection, and C) detector-related effects . The have estimated the systematic uncertainty introduced by various factors, and the results are summarized in Table 1 . The total systematic uncertainty is determined by adding the individual systematic uncertainties in quadrature. We expect that the total systematic uncertainty will be (SA /A I 6.4 x Just as important, the total correction due to systematic effects (AA/A) is less than 1.6 x

3 Summary

We have presented the essential elements of our plans to carry out an A correlation measurement using the UCN source we have constructed at the Manuel Lujan Neutron Scattering Center (MLNSC). Our goal is an initial measurement with an accuracy of about 0.2% of A (which has a value of about -0.1 14). The count rate expected in the experiment will allow a determination at this statistical accuracy level in a running time of about four months. It is important to note that the systematic effects in an experiment with UCN will be very different than those in the reactor experiments. Our estimates indicate that the total systematic uncertainty will be at the I 6.4 x 10" level. With such accuracy, one could address the issues of the discrepancy between the 0" + 0' decays and the unitarity of the CKM matrix. With possible increases in the UCN source intensity and a better understanding of systematic effects, we ultimately expect to be able to improve the accuracy beyond that of existing experiments by an order of magnitude or better. This would provide unprecedented sensitivity in the search for new Physics Beyond the Standard Model.

5 References

1) Klemt E. et al., Z. Phys. C37: 179 (1988). 2) Bopp P., et al., Phys. Rev. Lett. 56 (1986) 919, Bopp P. et al., Nucl. Instr. Meth. A267

3) Dohner J., et al., Nuc. Ins&. Meth. A284 (1989) 123. 4) Erozolimskii, B.G. et al., Phys. Lett. B236 (1991) 33. 5) Serebrov, A., private communication

436 (1 988).

6) Kuznetov, I., private communication 7) Schreckenbach, K. et al., Phys. Lett. B349 (1995) 427. 8) Abele, H. et al., Phys. Lett. B407 (1997) 212.

Table 1

I I I -1 Backscattered betas 5 1 0 ‘ ~ I 1 Scattered betas - residual gas contribution < 1 1 0 - ~ < 1 Scattered betas - wall contribution < 3 x < 3 x Field nonuniformities 2 x 7x Magnetic mirror effect < 5 1 0 - ~ < 5 Fiducial volume definition < 7 io5 <7x 1 0 ‘ ~

Subtotal Electron Collection 5.5 x lo4 1.5 x lo4

Detector inefficiencies < 2 x lo-> < 2 1 0 - ~ Detector resolution function 3 x lo4 3 1 0 - ~ Detector nonlinearity 5 5 1 0 - ~ Detector backgrounds - room 5 2 10” ~2~ 1 0 ‘ ~ Detector backmounds - beam associated < 1 < I Detector backgrounds - UCN related < 1 < 1 1 0 - ~

Subtotal Detector Effects 6.0 x lo4 5.8 x lo4

I TOTAL 1.6 10-~ I 6.4 x lo4

Table 1. Systematic effects and uncertainties. ANA is the size of the systematic effect relative to A (which has a value of -0.1 14) and (SA /A is the size of the systematic uncertainty relative to A.

6

b

6 L i F SB UCN DET€CTORS

TO 3He UCN DETECTOR

K C O I L S

SHUTTERS

ANGULAR

DETECTOR

REFLECTANCE TUBE ( T Y P I BOTH ENDS CORRELATION

SPECULAR SOLENO I D

SHUTTERS

UCN SWITCH SC SOLENOlD-

FROM UCN SOURCE ' \

DETECTOR

Figure 1: Layout of the A experiment. UCN enter from the guide tube at the bottom of the picture and pass through the polarizer and spin flipper before entering the decay volume. The circled numbers 1-6 indicate UCN shutters that may be opened and closed to make in situ measurements of the UCN depolarization. The beta detectors at the left and right end of the decay volume are shown in more detail in Figure 2.

ANGULAR CORRELATION DETECTORS

TO %e UCN DETECTOR

\ \ D I AMOND -COATED GUIDE TUBE

YiF SB UCN DETECTORS

I m o m - COATED GUIDE TUBE

Figure 2: Detail showing the end of the UCN bottle and the beta detectors.

The UCN A Collaboration consists of: B. Filippone, C. Jones, R. McKeown (California Institute of Technology), P. Geltenbort (Institut hue-hngevin), K. Soyama (Japan Atomic Energy Research Institute), T. Bowles (co-PI), T. Brun, M. Fowler, R. Hill, A. Hime, G. Hogan, S. Lamoreaux, C. Morris, S. Seestrom, P. Walstrom, J. Wilhelmy (Los Alamos National Laboratory), A. Alduschenkov, A. Kharitonov, M. Lassakov, Yu. Rudnev, A. Serebrov, A. Vasilev (Petersburg Nuclear Physics Institute), G. Cates, C-Y. Liu, B. Vogelaar, A.R. Young (co-PI) (Princeton University), T. Kitagaki (Tohoku University), K. Asahi (Tokyo Institute of Technology), B. Fujikawa (University of California at Berkeley, M. Hino, T. Kawai, M. Utsuro (University of Kyoto), A. Garcia (University of Notre Dame), L. Crow (University of Rhode Island), T. Miyachi (University of Tokyo)