Pulse Oximeter KPO-A100

Our model Pulse Oximeter KPO-A100 is designed to measure oxygen level in the blood. It suits for the pa-tients of COPD, Asthma and other lung diseases. It has silicon rubber shell protection with stable bracket.

Features:

• Supportive oximeter probe for adult, neonate and infants• 360 hours inner memory• Visual and sound alarm function• Compatible with Nellcor Spo2 Sensor using DB9 type connector • Auto switch off when no signal within 3 minutes• Standard 4×AAA 1.5V alkaline battery or rechargeable Li battery• USB port is available to upload the data to PC and review• Low Battery voltage indicator

Application:

Pulse Oximeter KPA-A100 is ideal for patients of acute and chronic respiratory disease and it is widely used in the clinical treatments.

Technical Parameters:

Model no. KPO-A100Display 2.8 inch TFT LCD

Display area 58×43mmSize 133x62x22mm

Weight 90gWorking voltage DC4.0V-6.0V or 3.5V-4.2V Li battery

Internal battery4 AAA alkaline battery or 1800MAH recharge-

able Li battery

Run time15h continuous operation with a new, full

charged batteryOperation Temperature 10℃-45℃

Transportation and Storage Temperature -20℃-60℃Operation Humidity 15%-95%(no condensing)

Transportation and Storage Humidity 10%-95%(no condensing)Operation Altitude 86KPa-106KPa

Transportation and Storage Altitude 50KPa-106KPaHemoglobin saturation display 35%-99%

SpO2 Resolution 1 %SpO2 Accuracy ±2% (70%-99%) unspecified (0%-69%)

PR Range 0bpm-250bpmPR Resolution 1bpm

Page 3: Pulse Oximeter - Medical Product · Pulse Oximeter KPA-A100 is ideal for patients of acute and chronic respiratory disease and it is widely ... SpO2 error is ±4%, pulse rate

Pulse Oximeter KIZLON

PR Accuracy ±1bpmPower Consumption ≤80mA

Low perfusion Condition ≤0.3%Channel Temperature 1

Average Time Constant <10SecActualization interval about 1SecAccuracy Temperature ±0.1°CResolution Temperature 18 ~ 45 °C

Measuring and Alarm Range Temperature 18 ~ 45°C

Page 4: Pulse Oximeter - Medical Product · Pulse Oximeter KPA-A100 is ideal for patients of acute and chronic respiratory disease and it is widely ... SpO2 error is ±4%, pulse rate

Pulse Oximeter KIZLON

Pulse Oximeter KPO-A101

Pulse Oximeter KPO-A101 non-invasively monitors an individual’s SpO2 and Pulse Rate parame-ters through finger. The principle of the oximeter is based on adoption of Photoelectric Oxy-haemo-globin Inspection Technology in accordance with Capacity Pulse Scanning & Recording Technology.

Features:

• Displays SpO2 value, pulse rate value and bar graph• Integrated with SpO2 probe and processing display module• It is small in, light in weight and convenient in carrying• The operation of the product is simple and low on power consumption• It has an indicator of low-voltage• The device automatically turns off the power when the device is under the state of measuring interface, e.g. it will automatically power off within 5 seconds if the finger falls out of probe

Application:Pulse oximeters are used to measure SpO2 and PR at any time like at home, work or recreation or in any sports or high-altitude activity.

Technical Parameters:

Model no. KPO-A101

Display mode LED display

SpO2 measuring range 0-100% (resolution is 1%)

Accuracy 70-100% ±2% (below 70%, it is unspecified)

PR measuring range 30-250bpm (resolution 1bpm)

Accuracy ±2bpm or ±2% (larger is selected)

Measurement performance in weak filling conditionSpO2 and pulse rate can be shown correctly when

pulse-filling ratio is 0.4%. SpO2 error is ±4%, pulse rate error is ±2bpm or ±2% (larger is selected)

Resistance to surrounding lightThe deviation between the value measured in the condition of man-made light or indoor natural light and that of dark-

room is less than ±1%

Power Consumption <25mA

Voltage DC 2.6-3.6V

Power Supply 1.5V (AAA size) alkaline batteries × 2

Battery working hourThe minimum continually work time is 24 hours ,theoret-

ical number is 56 hours

Safety Type Interior Battery, BF Type

Dimension 66×36×33mm

Weight 50g (with the batteries)

Page 5: Pulse Oximeter - Medical Product · Pulse Oximeter KPA-A100 is ideal for patients of acute and chronic respiratory disease and it is widely ... SpO2 error is ±4%, pulse rate

Pulse Oximeter KIZLON

Pulse Oximeter KPO-A102

KPO-A102 is a portable Pulse Oximeter non-invasively measuring SpO2 and PR value through the finger.

Features:

• Displays SpO2 value, pulse rate value, pulse waveform and bar graph• Automatic storage of SpO2and PR values• PR sound can be heard• Display mode can be changed and brightness can be adjusted• It has alarm function and automatically turns off the power if there is no operation for 1 min• It has an indicator of low-voltage• Has feature of wireless transmission and the data stored can also be uploaded to APP by Blu tooth, APP will upload the data to CLOUD platform for analyzing

Application:Pulse oximeters are used to measure SpO2 and PR at any time like at home, work or recreation or in any sports or high-altitude activity.

Technical Parameters:Model No. KPO-A102

Display mode LED display

SpO2 measuring range 0-100% (resolution is 1%)

Accuracy 70-100% ±2% (below 70%, it is unspecified)

PR measuring range 30-250bpm (resolution 1bpm)

Accuracy ±2bpm or ±2% (larger is selected)

Measurement performance in weak filling conditionSpO2 and pulse rate can be shown correctly when

pulse-filling ratio is 0.4%. SpO2 error is ±4%, pulse rate error is ±2bpm or ±2% (larger is selected)

Resistance to surrounding lightThe deviation between the value measured in the condition of man-made light or indoor natural light and that of dark-

room is less than ±1%

Working voltage DC 3.6-4.2V

Battery 3.7V Rechargeable lithium battery (Long Battery Life)

Optical sensorRed light (wavelength is 660nm,6.65mW), Infrared (wave-

length is 880nm, 6.75mW)

Adjustable alarm range SpO2 : 0%~100%,

Pulse Rate: 0bpm~254bpm Interior Battery, BF Type

Dimension 57× 32× 30mm

Weight 50g (with the batteries)