15
PUMP CONDITION PUMP CONDITION EVALUATION EVALUATION http://www.mecha http://www.mecha nicalseals.net/ nicalseals.net/

Pump Condition Evaluation

Embed Size (px)

DESCRIPTION

Seal chamber / Gland fit - Gland Boss must be perpendicular to the pump shafthttp://mechanicalseals.net/

Citation preview

  • PUMP CONDITION EVALUATIONhttp://www.mechanicalseals.net/

  • PUMP CONDITION EVALUATIONBEARINGSPUMP SHAFTBEARING FRAMEREAR COVER IMPELLERPUMP CASE

  • PUMP CONDITION EVALUATIONVibration - Imperfections on rollers/balls will cause seal face chatterEnd Play - Closing force on the seal faces will varyRun OutSeal faces will not run in a concentric pathSeal faces will not run parallelVibration will occur

    BEARINGS

  • CHECKING BEARING RELATED END PLAYTotal Indicator Readingshould not exceed.010

  • CHECKING BEARING RELATED END PLAYTIR should not exceed.010

  • CHECKING BEARING RELATED RUN OUTTIR should not exceed.002

  • CHECKING BEARING RELATED RUN OUTTIR should not exceed.002

  • PUMP CONDITION EVALUATIONBent ShaftRun OutVibrationBearing FitsRun OutEnd PlayShaft Sleeve Fit - Run OutImpeller Thread/Fit - Vibration

    PUMP SHAFT

  • CHECKING SHAFT RELATED RUN OUTTIR should not exceed.001 per 2 distance from bearing

  • CHECKING SHAFT RELATED RUN OUTTIR should not exceed.001 per 2 distancefrom bearing

  • PUMP CONDITION EVALUATIONOutboard Bearing Housing fit in FrameBearing FitsRun OutBearing SpinVibrationBEARING FRAME

  • PUMP CONDITION EVALUATIONSeal chamber / Gland fit - Gland Boss must be perpendicular to the pump shaftImperfections or wear on the impeller side of the rear cover will effect the performance of pump out vanes which in turn, effects seal chamber conditionsStuffing box pressurefluid turbulenceREAR COVER

  • CHECKING GLAND BOSS FOR PERPENDICULARITYTIR should not exceed.005 up to 5 Dia. (+.001"/in. >5)

  • PUMP CONDITION EVALUATIONExcessive wear will effect pump performance which will effect stuffing box conditionsImpeller fit on shaft must be trueWith open impeller pumps, proper impeller / case clearance is a must for optimum pump performance and must be done before installing a new sealIMPELLER & PUMP CASE

  • PUMP CONDITION EVALUATIONhttp://mechanicalseals.net/